Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
338 Macleod Ave_BLD6233_2025
CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 338 MACLEOD AVE Permit #: 6233 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00529900200100 DATE OF ISSUANCE. Scope of Work: Replace failed fire alarm panel with "like for like" Valuation: 3000.00 OWNER APPLICANT CONTRACTOR ARLINGTON UNITED CHURCH NW Security & Sound NW Security & Sound PO BOX 266 PO Box 1592 PO Box 1592 ARLINGTON, WA 98223 Snohomish Snohomish, WA 98291 4255080610 360-691-4200 LIC: 602 955 964 EXP: 10/31/2025 LIC: NWSECSS919PG EXP: 10/07/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 2 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: A-1; Assembly BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 11/19/2024 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections. Adhere to approved plans. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/19/2024 Web Only - Fire System Plan Review $200.00 11/19/2024 Processing/Technology $25.00 11/19/2024 Fire Alarm System Permit $75.00 Total Due: $300.00 Total Payment: $300.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail DF-52416:D • A3-20 MS-5UD(E)/MS-10UD(E) Series Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel Control/Communicators General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze†signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), 52416cov.jpg three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone – Strobe Synchronization for System Sensor, Wheelock, line integrity. Gentex, Faraday, or Amseco devices. Activation of a compatible smoke detector or any normally- – Selective Silence (horn-strobe mute). open fire alarm initiating device will activate audible and visual – Temporal or Steady Signal. signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and – Silenceable or Nonsilenceable. FACP alarm relay, and operate an optional module used to • Optional CAC-5X Style Z (Class A) Converter Module for notify a remote station or initiate an auxiliary control function. NACs and IDCs (2 required for MS-10UD-7). New options include a UL listed printer, PRN-6F and FireLite’s • Form-C Relays for Alarm, Trouble and Supervisory - Con- IPDACT Internet Monitoring module. The FireWatch Series tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). internet monitoring modules IPDACT-2 and IPDACT-2UD per- • 3.0 A total system current for MS-5UD-3. mit monitoring of alarm signals over the Internet saving the • 7.0 A total system current for MS-10UD-7. monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup • Optional Dress Panel DP-51050 communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush mounting. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- • 24 volt operation. tures as the MS-5UD-3 and MS-10UD-7 but allow connection to • Low AC voltage sense. 240 VAC. Unless otherwise specified, the information in this data • Alarm Verification. sheet applies to both the 120 VAC and the 240 VAC versions of these panels. • PAS (Positive Alarm Sequence). NOTE: For ULC-listed models, see DF-60440. • Automatic battery trickle charger. • Up to eight ANN-BUS annunciators: Features – Optional 8 zone Relay Module ANN-RLY. • Listed to UL Standard 864, 9th edition. – Optional LED Annunciator Module ANN-LED, • Built-in DACT (Digital Alarm Communicator/Transmitter). – Optional Remote Annunciator ANN-80. • Style B (Class B) IDC (Initiating Device Circuit) – Optional Remote Printer Gateway ANN-S/PG. – MS-5UD-3 - five IDCs. – Optional LED Annunciator Driver ANN-I/O. – MS-10UD-7 - ten IDCs. • Optional 4XTMF module (conventional reverse polarity/city box transmitter). • Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power PROGRAMMING AND SOFTWARE: – MS-5UD-3 - four NACs. • Can be programmed at the panel with no special software – MS-10UD-7 - four NACs. or additional equipment. • Notification Appliances may be programmed as • Programmable Make/Break Ratio. – Silence Inhibit. • Upload/Download (local or remote) of program and data via – Auto-Silence. integral DACT. DF-52416:D • 07/26/2010 — Page 1 of 4 USER INTERFACE: • SYSTEM RESET (lamp test) • Built-in DACT (Digital Alarm Communicator/Transmitter). •DRILL • Integral 80-character LCD display with backlighting and keypad. Terminal Blocks • Real-time clock/calendar with automatic daylight savings AC Power – TB1: adjustments. • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, • ANN-BUS for connection to remote annunciators. 1.00 A. • Audible or silent walk test capabilities. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, • Piezo sounder for alarm, trouble, and supervisory. 0.54 A. • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, Controls and Indicators 3.80 A. • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, LED INDICATORS 2.20 A. • FIRE ALARM (red) Wire size: minimum 14 AWG (2.00 mm²) with 600 V insulation. • SUPERVISORY (yellow) Supervised, nonpower-limited. • TROUBLE (yellow) Battery (sealed lead acid only) – J12: • AC POWER (green) • Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC • ALARM SILENCED (yellow) @ 1.4 A. Supervised, nonpower-limited. CONTROL BUTTONS • Maximum Charger Capacity: 18 AH battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- • ACKNOWLEDGE teries can be housed in the FACP cabinet. Larger batteries • ALARM SILENCE require separate battery box such as the BB-26 or BB-55.] 52416cab.wmf Cabinet Measurements Page 2 of 4 — DF-52416:D • 07/26/2010 • Minimum Battery Size: 7 AH. MS-10UD-7E: Same as above with 240 VAC FLPS-7. Initiating Device Circuits – TB4 (and TB 6 on MS-10UD-7 IPDACT, IPDACT-2/2UD Internet Monitoring Module: only): Mounts in bottom of enclosure with optional mounting kit (PN • Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7). IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer • Alarm Zones 6 - 10 on TB6 (MS-10UD-7 only). provided ethernet internet connection. Requires compatible • Supervised and power-limited circuitry. Teldat Visoralarm Central Station Receiver. Can use DHCP or • Operation: All zones Style B (Class B). static IP. (See data sheet DF-60407 for more information.) • Normal Operating Voltage: Nominal 20 VDC. IPBRKT: Mounting kit for IPDACT in common enclosure. • Alarm Current: 15 mA minimum. IPSPLT: Y Adaptor option to allow connection of both panel • Short Circuit Current: 40 mA max. dialer outputs to one cable input to IPDACT (sold separately). • Maximum Loop Resistance: 100 ohms. OPTIONAL MODULES • End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- CAC-5X: Optional (Class A) Converter Module. Converts Style listed). B (Class B) Initiating Device Circuits to Style D (Class A); and • Standby Current: 2 mA. Style Y (Class B) Notification Appliance Circuits to Style Z Refer to the Fire•Lite Device Compatibility Document for listed (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- compatible devices. 7(E) main circuit board and to J7 on the MS-10UD-7(E). Notification Appliance Circuits – TB5 (and TB 7 on MS- NOTE: Two Class A Converter Modules are required for the ten- 10UD-7 only): zone panel. • Four NACs 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble • Operation: Style Y (Class B) reverse polarity. Includes a disable switch and disable trouble • Special Application power LED. A module jumper option allows the reverse polarity circuit • Supervised and power-limited circuitry to open with a system trouble condition if no alarm conditions • Normal Operating Voltage: Nominal 24 VDC exists. Mounts to the main circuit board connectors J4 and J5. • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A COMPATIBLE ANNUNCIATORS maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- ANN-80: Remote LCD Annunciator. Mimics the information mum per NAC. displayed on the FACP’s LCD. Red. (For white, order: ANN- • End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) 80-W.) • Max. Wiring Voltage Drop: 2 VDC ANN-LED: LED Annunciator with three LEDs for each zone: Refer to the Fire•Lite Device Compatibility Document for com- Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) patible listed devices. dress panel. Red. (For white, order ANN-LED-W.) Form C Relays – TB8: ANN-RLED: LED Annunciator with three alarm (red) indica- • Relay 1 (factory default programmed as Alarm Relay) tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). • Relay 2 (factory default programmed as fail-safe Trouble Relay) ANN-RLY: Relay module. Mounts inside the cabinet. Provides • Relay 3 (factory default programmed as Supervisory Relay) ten Form C relays. Special Application Resettable Power – TB9: ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. • Jumper selectable by JP31 for resettable or nonresettable power. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. • Operating voltage: 24 VDC nominal. • Maximum available current: 500 mA - appropriate for pow- ACCESSORIES ering four-wire smoke detectors. DP-51050: Optional dress panel. Restricts access to the sys- • Power-limited circuit. tem wiring while allowing access to the membrane switch Refer to the Fire•Lite Device Compatibility Document for listed panel. compatible devices. BB-26: Battery backbox, holds up to two 25 AH batteries and Remote Sync Output - TB2: Remote power supply synchro- CHG-75. nization output, only required for the MS-5UD-3. 24 VDC nom- BB-55: Battery backbox, holds up to two 25 AH batteries. inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- TR-CE: Optional trim-ring for semi-flush mounted cabinets. ited circuit. PRN-6F: UL listed printer. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). DF-52416:D • 07/26/2010 — Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Annunciators ......................................................................8 This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH Electrical Specifications (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic • MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, components may be adversely affected by extreme tempera- 1.0 A ture ranges and humidity. Therefore, it is recommended that • MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, this system and its peripherals be installed in an environment 3.90 A with a normal room temperature of 15 – 27°C/60 – 80°F. • MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. Agency Listings and Approvals • MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, The listings and approvals below apply to the basic MS-5UD-3 2.20 A. and MS-10UD-7 control panels. In some cases, certain mod- • Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- ules or applications may not be listed by certain approval tion, supervised, nonpower-limited agencies, or listing may be in process. Consult factory for lat- est listing status. Cabinet Specifications • UL Listed: File S624 Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x • FM Approved 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x • CSFM: 7165-0075:0214 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring • MEA: MEA: 333-07-E (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. NOTE: For ULC-listed models, see DF-60440. Shipping Specifications NFPA Standards Dimensions: The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- – 20.00" (50.80 cm.) high lowing NFPA 72 Fire Alarm Systems requirements: – 22.5" (57.15 cm.) wide – LOCAL (Automatic, Manual, Waterflow and Sprinkler – 8.5" (21.59 cm.) deep. Supervisory). Weight: 27 lb (12.20 kg) –AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). – REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) –PROPRIETARY (Automatic, Manual and Waterflow). – CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). –OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — DF-52416:D • 07/26/2010 !"#$%&#'#"%()*+, -+ ./0 123(-, "%453&,#) ./0.6677 89:&;<= ./0>?>@>A 3#&+&B"C+ ?0 "-D9E: "(# F0 <<GHG G I/ "-DJ#KC(-, "%4L#)C&,#)M-&B @NOP (Q!L-(RL"!()R" (L!L BQL#(!K"%+S!"D(R& !"D(S T/U0 GGGMGG @VUW =HG UXN@7 ?07U0 Y: ZU0[U \]CC(B^!4 _ ?6 _77U6 = G I`7 G< G G < W @U7 *98a .77b06 cL##L+cL )K"-D 8L -(!d )) (CC($L!e(C- "Q%"	K#( 1LB( 9K#( 8+&#( f&#"#$ =(!"$"&,C 1ga91 GG< ==GG GGGG # # $% & '!"( !!" ) *+ $ !+!( $% & ' ,-( % 2 . / 0 # 0 0 $% & ' !1 3456 789:8;< & "* =1&! ) ( ="* > $% & ' !"( ?88< &! - ! A !- A!/ A! !-B ! A! @2 . 1 ! >1- "* D ! C! ! )=+ )1 D ! !- >1- !- E E DE FGH54 IJKKLKK MHH5NO8P Q8HH8R< & !&! STUVWUXY Z[\]U^ _[` ab\] c STUVWUXY deeVUfg^UbX 35hi86H< & ( $1&! 1- =1( $1- j$ , A/ D 000# j$ , A/ D klH<H56P:6m n5456N8 IKLKK oGH8< & ,!( $1/ p (( + p! ( A!- # ( +( A + ! ! 0 p! q + q!(*C p! q + q!(*C rs4G5P8P ?:48< & - tutvwxytctztv{S|}~tuu{€€T[WZ[\]U^ÂeW‚ tutvzƒywctztvxxxƒ{S|}~tuu{dee\b„[W e[f€ÂeW‚ yf`gv`†z[†x‚gfx†uv~[~wtuf‚yWv[zƒ{g\VUXY^bX{TXU^[W{f‡T\f‡{‚U\[{e[\]U^{geeVUfg^UbXÂeW‚ G\ =\ GG89:&;<= ': G =<<= *91a*a9 *913a'*a91 123(-, "%453&,#)"-D9E: "(# G\ =\ GG89:&;<= 5123*33==8g *91a*a9 _0707 eL%(#CQ(-%"&#a4Q(e(C- "Q%"-+(),!()eL%(*&BQ!(%()eL%(#CQ(-%& 3%L%,C