Loading...
HomeMy WebLinkAbout18311 Woodbine Dr_BLD6462_2025 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 18311 WOODBINE DR Permit #: 6462 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00800700000600 DATE OF ISSUANCE. Scope of Work: add a heat pump to existing hvac system Valuation: 12600.00 OWNER APPLICANT CONTRACTOR MCCABE SHARON Bobs Heating BOB'S HEATING 18311 WOODBINE DR 14148 NE 190th st 14148 NE 190th St ARLINGTON, WA 98223 Woodinville wa 98072 Woodinville, WA 98072 2069390384 206-378-6723 LIC: BOBSHHA853NQ EXP: 09/07/2025 LIC: 603 522 028 EXP: 07/31/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3; Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 04/17/2025 Applicant Signature Date Building Official Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliances. Approved permit shall be onsite for inspections. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 04/17/2025 Processing/Technology $25.00 04/17/2025 Inspection $75.00 04/17/2025 Heat Pump - Condensing Unit $25.00 04/17/2025 Mechanical Base $25.00 Total Due: $150.00 Total Payment: $150.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit:  New Installation  Addition/Alteration/Repair  Gas Piping 18311 Woodbine Dr 12600 Property Address: Project Valuation: Lot #: Parcel ID No.: 00800700000600 Preferred Contact:  Owner  Contractor Add A heat pump to existing hvac system Project Description: Sonny Thompson 3607203056 Owner Name: Home No.: Email Address: Cell No.: 18311 Woodbine Dr Arlington wa 98223 Mailing Address: City: State: Zip: Contractor Name: Bobs Heating Office No.: 8008403346 Email Address: lhoneycutt@bobsheating.com Cell No.: 2069390384 Mailing Address: 14148 ne 190th st City: woodinville State: wa Zip: 98072 L&I Contractor License Number: BOBSHHA853NQ Expiration Date: 09/07/2025 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information  Not Applicable  CSST Brass Other Proposed Piping Material: Black Steel Galvanized Steel _______________________________________ Proposed Piping Size: ½”  ⅝”  ¾”  1”  1½”  2” Distance from Meter to furthest Appliance: Total BTU’s of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $ 75.00 = Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = Air Conditioning Unit > 100 Btu/h x $ 25.00 = Air Conditioning Unit > 500 Btu/hp x $ 50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $ 25.00 = $ 25.00 Boiler <100Btu/h >3hp x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler >1 million Btu/h<50hp x $ 25.00 = Boiler >1.5 million Btu/h<50hp x $ 50.00 = Boiler >100Btu/h 3-15hp x $ 15.00 = Boiler >500Btu/h 15-30hp x $ 25.00 = Commercial Hoods -Type I x $ 25.00 = Commercial Hoods -Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork (drawings required) x $ 25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat ≤100 Btu/h x $ 15.00 = Forced Air Heat >100 Btu/h x $ 25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit ≤ 100 Btu/h x $ 15.00 = Gas Fired Air Conditioning Unit > 100 Btu/h x $ 25.00 = Gas Fired Air Conditioning Unit > 500 Btu/hp x $ 50.00 = Gas Piping ≤ 5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $ 2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $ 25.00 = 25.00 38MURAQ36aab3 Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance - regulated by $ 15.00 x = mechanical code, not otherwise specified Package Units ≤ 100 Btu / > 100 Btu x $ 25.00/$50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit ≤100Btu/h x $ 15.00 = Refrigeration Unit >100Btu/h x $ 25.00 = Refrigeration. Unit >500Btu/h x $ 50.00 = Re-inspection fee x $ 75.00 = Residential Range Hood x $ 15.00 = Unit Heaters ≤ 100 Btu/h x $ 15.00 = Unit Heaters >100 Btu/h x $ 25.00 = Variable Air Volume Boxes (part of Air $ 10.00 x = Conditioning System) Wall Heaters - Gas Fired x $ 25.00 = Water Heater - Gas Fired x $ 25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Lucinda Honeycutt 4/17/25 Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY  SCHEMATIC IS TO SCALE  SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 Outdoor Unit Single Zone Heat Pump Ductless System Outdoor Model: 38MARBQ36AA3 Submittal Data Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto-Restart function • Condenser High Temp Protection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Anti-corrosive fin coating LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. NOTE: Images for illustration purposes only. Actual models may be slightly different. Size 36 Face Area Sq. Ft. 24.0 System Outdoor Model 38MARBQ36AA3 No. Rows 3 Outdoor Coil Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 Fins per inch 18 Electrical MCA A. 28 Circuits 6 MOCP - Fuse Rating A. 35 Type Rotary Inverter Operating Cooling Outdoor DB Min - Max °F(°C) -22~122 (-30~50) Model KTF250D22UMT Range Heating Outdoor DB Min - Max °F(°C) -22~86 (-30~30) Compressor Oil Type VG74 Total Piping Length ft (m) 213 (65) Oil Charge Fl. Oz. 22.7 Piping Piping Lift* ft (m) 98 (30) Rated Current RLA 18.0 Pipe Connection Size - Liquid in (mm) 3/8 (9.52) Unit Width in (mm) 37.24 (946) Pipe Connection Size - Suction in (mm) 5/8 (16) Unit Height in (mm) 34.84 (885) Refrigerant Type R410A Unit Depth in (mm) 16.14 (410) Outdoor Refrigerant Metering Device EEV Net Weight lbs (kg) 150.13 (68.1) Charge lbs (kg) 7.50 (3.40) Airflow CFM 2,235 * Condensing unit above or below indoor unit Sound Pressure dB(A) 61.5 For Compatibility See Product Data Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 002/2021 Catalog No: 38MARB-36-3-01SB SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: NEW Performance Indoor Model 40MAHBQ36XA3 Energy Star NO Cooling Rated Capacity Btu/h 36,000 Cooling Cap. Range Min - Max Btu/h 9,300~38,800 SEER 17.5 EER 8.5 Heating Rated Capacity (47°F) Btu/h 36,000 Heating Rated Capacity (17°F) Btu/h 22,400 High WallHeating Maximum Capacity (17°F) Btu/h 23,600 Heating Maximum Capacity (5°F) Btu/h 20,400 Heating Cap. Range Min - Max Btu/h 11,570~37,000 HSPF 9.0 COP (47°F) W/W 2.51 COP (17°F) W/W 2.18 COP (5°F) W/W 1.75 Construction View Outdoor Model: 38MARBQ36AA3 Copyright 2021 CAC/BDP ● Atlanta, GA. 30339 Edition Date: 002/2021 Catalog No: 38MARB-36-3-01SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: NEW         !"! #$%& '()*+(, -.%/& 0(1+"2345,6 -.%/-7788   9:4'+4 -.%/;<;=;> ?((@5,A5BB2C3:9 <#/% DE5,@3"(,2FED44 G#/  :H:H9 I. B'(,2FED44J1(1+'2345,6KE() =%##LM#N 3@@3'234*D)*4(2O5+45,6'A3E+F+42) P.Q#/  K =RQS 9:H &QT#L=#8  <#/8Q%#/ U0 V%%Q/%W#Q XHY2+5@2,453B Z <#7 Z88Q7  9   I[8    S#  !"! =Q8 !\ ] -88^/7# "3,,3'"3_@C5E` # ]3_E2Ba @@_2++263B2+E_5*45(,\C,2_3)2 \C,2_]'(,2 b(,5,6 c 9 9H?\\0 !!0"\ d e ! <#/%#8 !(,4_3E4(_]_5)3_F!(,43E4]'(,2@@_2++!(,4_3E4(_F*25E2,+2 5E2,+2a DE5,@3   9:4' !\g!\ 31(_h 0\0f"c  XH9X  H 0\0""9Hi "(,2FED44 4 !\!\ ,@D+4_52+ DE5,@3   9:4' !\g!\ 0\0f"c  XH9X  H !\ H  9 "(,2FED44 4 !\!\ Z/8%#/8 342,+*2E45(,F*22+E_5*45(,E'2@DB2@342!()*B242@342,+*2E4(_434D+       !!!" # $$%&' ( ))"    *++, '- )   . /- #0-!# 1 )-  12 /.)3  #&  4.  1 - -!%/  1   5" - 16 789:; <=>?@>A B99:CD+EF+99+G, ' '- )  62 HIJKLJMNOPQRJS 62 TPUVWQRXYPZJLPMSJ[K\P]^[MJ][K_``KJ][SJWM a:bc+d9, ' / %'- ) /0) --)% . 62 5 .5#eeeee   -f 16 g%/ h 62 1 eeeee ij9,9:dEkdlm:;:dC+ <A@AA no;8:E+E*k;+, '  !  6e pqqpqrstXpupqvHwxytypvzZZIPLOPQRJS{`L| 62 Pu}PL[tu~tqq|}u[]}p[sU~[]ut[~quvS^WR`ZWMvZvZJSPv`K[M{€`N 62 ‚ƒ‚„ „‚ †‡‡†ˆ‰Š‹Œ ŒŽŽ„‹Œ„ Œ‹ƒ‡‰‘’“ƒ”“ƒ“Žˆ•’–—Œ‹ 62 ЉŒ‚‡‚Žƒ‡”‰„ˆŒŒƒ‚‰ŠŒ‡’” ‡‹‡” އˆ”ƒ“‘‚•˜Œ‚™š˜‰›‚œ‰™˜‰›–—Œ‹