HomeMy WebLinkAbout219 Joann Ln_BLD4313_2025 219 Joann Ln INSTALLING DUCTLESS HEAT PUMP Shawn Anderson 219 Joann Ln Arlington WA 98223 20681863396 shawn.m.anderson14@gmail.com KAREN MATHENEY/WASHINGTON ENERGY SERVICES 3909 196TH ST SW LYNNWOOD WA 98036 2063786648 PERMITS@WASHINGTONENERGY.COM WASHINGTON ENERGY SERVICES 3909 196TH ST SW LYNNWOOD WA 98036 WASHIES851NS 9/7/23 2063786648 PERMITS@WASHINGTONENERGY.COM RXS18LVJU ✔ ✔ 12/15/2021 KAREN MATHENEY CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 219 JOANN LN Permit #: 4313 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00747800000500 DATE OF ISSUANCE. Scope of Work: Installing ductless heat pump Valuation: .00 OWNER APPLICANT CONTRACTOR ANDERSON SHAWN M Washington Energy Services WASHINGTON ENERGY SERVICES 219 JOANN LN 3909 196th St SW 3909 196th Street SW ARLINGTON, WA 98223-8254 Lynnwood, WA 98036 Lynnwood, WA 98036 2063786648 2063786648 LIC: WASHIES851NS EXP: 09/07/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR WASHINGTON ENERGY SERVICES 3909 196th Street SW Lynnwood, WA 98036 2063786648 LIC #: WASHIES851NS EXP: 09/07/2023 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 12/15/2021 Signature Print Name Date Released By Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliances. Approved job copy shall be onsite for inspections; if applicable. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. Date Description Fee Amount 12/16/2021 Processing/Technology PERMIT FEES $25.00 12/16/2021 Inspection $75.00 12/16/2021 Forced Air Heat $15.00 12/16/2021 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 219 JOANN LN Permit #: 4313 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00747800000500 DATE OF ISSUANCE. Scope of Work: Installing ductless heat pump Valuation: .00 OWNER APPLICANT CONTRACTOR ANDERSON SHAWN M Washington Energy Services WASHINGTON ENERGY SERVICES 219 JOANN LN 3909 196th St SW 3909 196th Street SW ARLINGTON, WA 98223-8254 Lynnwood, WA 98036 Lynnwood, WA 98036 2063786648 2063786648 LIC: WASHIES851NS EXP: 09/07/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR WASHINGTON ENERGY SERVICES 3909 196th Street SW Lynnwood, WA 98036 2063786648 LIC #: WASHIES851NS EXP: 09/07/2023 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 12/15/2021 Signature Print Name Date Released By Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliances. Approved job copy shall be onsite for inspections; if applicable. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. Date Description Fee Amount 12/16/2021 Processing/Technology PERMIT FEES $25.00 12/16/2021 Inspection $75.00 12/16/2021 Forced Air Heat $15.00 12/16/2021 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon Arlington Site Plan Shawn Anderson SITE PLAN DRAWING 219 Joann Lane Anderson - 219 Joann Lane Arlington 98223 Customer _______________________________________________________________ Arlington Wa. 98223 Heat Pump Placement Location North Prop Line N W Heat Pump Location E 26' S 32' Shed 219 Joann Ln Prop Front Line Entry Prop Line Prop Line Joann Lane Job Name: Tag# Submittal Data Sheet FTXS18LVJU / RXS18LVJU 1.5-Ton Wall Mounted Heat Pump System Efficiency Cooling Heating SEER 20.3 HSPF 11.0 EER 12.7 COP 3.70 Performance Cooling (Btu/hr) Rated (Min/Max) 18,000 (5,800 / 18,000) Sensible @ AHRI 14,790 Moisture Removal gal/h 1.0 Operating Range 50°F – 115°F Rated Cooling Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB Complete warranty details available from your local dealer or at Heating (Btu/hr) www.daikincomfort.com. To receive the 12-Year Parts Limited 1:@ 47° Rated (Min/Max) 21,600 (5,800 / 21,600) Warranty, online registration must be completed within 60 days of 2: @ 17° Rated 13,900 installation. Online registration is not required in California or Quebec. 3: @ 5° Max 9,650 If product is installed in a commercial application, limited warranty Operating Range 5°F – 65°F period is 5 years. 1: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB Indoor Specifications 2: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Cooling Heating Outdoor: 17°F DB/15°F WB H M H M 3: Rated Heating Conditions: Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB Airflow Rate (cfm) 583 484 625 526 L SL L SL Electrical 385 360 431 399 208/60/1 230/60/1 Sound (dBA) 46 / 41 / 36 / 33 45 / 40 / 35 / 32 System MCA 13.75 13.75 H / M / L / SL System MFA 20 20 Dimensions (H × W × D) (in) 13-3/8 × 41-5/16 × 9-3/4 Compressor RLA 6.6 5.9 Weight (Lbs) 31 Outdoor fan motor FLA .32 .32 Outdoor fan motor W 53 53 Outdoor Specifications Indoor fan motor FLA .32 .32 Compressor Hermetically Sealed Swing Type Indoor fan motor W 48 48 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) Refrigerant R-410A RLA: Rated load amps (A) W: Fan motor rated output (W) Refrigerant Oil PVE (FVC50K) Piping Cooling Heating Liquid (in) 1/4 Gas (in) 1/2 Airflow Rate (cfm) H 1,780 H 1,444 Drain (in) 5/8 L 1,494 L 1,328 Max. Interunit Piping Length (ft) 98.4 Sound Power Level (dBA) 63 Max. Interunit Height Difference (ft) 65.6 Dimensions (H × W × D) (in) 28-15/16 × 32-1/2 × 11-13/16 Chargeless (ft) 32.8 Weight (Lbs) 104 Additional Charge of Refrigerant (oz/ft) .21 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: June 2017 Page 1 of 4 FTXS18LVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: June 2017 Page 2 of 4 RXS18LVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: June 2017 Page 3 of 4 Optional Accessories Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter BRC944B2-A08 Wired Remote Controller BRCW901A08 Wired Remote Controller Cord - 3m DACA-BRCW901P10 Remote Controller Cable, Plenum Rated, 10 ft DACA-BRCW901P25 Remote Controller Cable, Plenum Rated, 25 ft DACA-TS1-1 Daikin ENVi Intelligent Thermostat Kit DACA-CP1-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Description DACA-WB-3 Powder-Coated Wall-Mounted Bracket KEH041A42 Drain Pan Heater RXS15_18LV KKP937A4 Drain Plug for OD Unit KPW945A4 Low Ambient Wind Baffle / Air Adjustment Grille (15/18/24 MBH) Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date: June 2017 Page 4 of 4         !"#$ %&'()*% +,#-$ ./)01%23*%%'(24'(516') +,#-+7788 9:9 9;303. +,#-<=<><? 4%%@**&A.9B: ; =!-# C/('%/30'%'4 D!- :; EB;; B F, G'(H13)I@/)01%23*%'%'(24J6*H >#!!KL!M %)3/NN1%2&O63N'))0'/3GOHG P,Q!- :J:: >RQS : $QT!K>!8 : =!-8Q#!- U##Q-#V!Q W =!7 W88Q7 FX8 :; : S! >Q8 YZ +88[-7! H'(')1//@N1) ! Z/(6'N\ &&('))'2/N')6(1G31*%Y@%'(/H' Y@%'(Z0*%' ]*%1%2 ::_ Y ::E EB::::::: 9^Y `a  .  =!-#!8 *%3(/63*(Z(1H/(4*%3/63Z0*%'&&('))*%3(/63*(4G'16'%)' 16'%)'\ . _Y 9:9 9;303(''3 YcY C/('%/30'%'4:; EB;; B Y ;: :  _ab . YY . _Y 9:9 9;303(''3 YcY /d*(e C/('%/30'%'4:; EB;; B . B  _ab . YY %&O)3(1') W-8#!-8 /3'%)G'631*%4G'')6(1G31*%60'&ON'&/3'*HGN'3'&/3'%)G'63*(3/3O)        !" ##$%&'   ())* !+$#,%%,+ %-, .$%++/%%/0 1 +#,% 1 %$' $ 2,3 #$ ,- 1 4 +.$,  1 $', $' $& 15 6789: ;<==>?@ A889BC)D E)88)F* !, ,,$!+$#,%  GHIJKILM NOPQIR S9TU)V8* !, .' 0!+$#,%.0, 0# #,' 0 %-,   "  WWWW 15  WWWW $+ X+ 15 YZ8*89VD[V\ ]9:9VB) ;@>@@ ^_:79D)D ([:)* !,    `abac`defgd`dhNOPQIR ijklmnopKq  `ad`dgbdfgd`dhiIRO NJrLopKq  `ad`dgbgfgd`dhipOstopKq  `ad`dgbufgd`dhvppJIsrRIwLopKq