HomeMy WebLinkAbout8902 170th St Ne_BLD4327_2025 8902 170TH ST NE A/C ADD TO EXISTING HVAC EQUIPMENT WILLIAM HUNTLEY 8902 170TH ST NE ARLINGTON WA 98223 360-202-7028 WILLIAM_HUNTLEY@MSN.COM BARRON HEATING / MISTY CHANDLER 5100 PACIFIC HWY #103 FERNDALE WA 98248 360-676-1131 MISTYC@BARRONHEATING.COM BARRON HEATING 5100 PACIFIC HWY #103 FERNDALE WA 98248 BARROHA179D7 10/23/22 360-676-1131 MISTYC@BARRONHEATING.COM EL16XC1S036-230 16 ✔ ✔ 12/17/2021 Misty Chandler CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 8902 170TH ST NE Permit #: 4327 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 01166900005800 DATE OF ISSUANCE. Scope of Work: Add A/C to existing HVAC equipment Valuation: .00 OWNER APPLICANT CONTRACTOR HUNTLEY WILLIAM/ELIZABETH Barron Heating BARRON HEATING & A.C. 8902 170TH ST NE 5100 Pacific Hwy #103 5100 Pacific Highway #103 ARLINGTON, WA 98223 Fernale, WA 98248 Ferndale, WA 98248 360-676-1131 360-676-1131 LIC: BARROHA179D7 EXP: 10/23/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR BARRON HEATING & A.C. 5100 Pacific Highway #103 Ferndale, WA 98248 360-676-1131 LIC #: BARROHA179D7 EXP: 10/23/2022 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. Signature Print Name Date Released By Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliances. Approved job copy shall be onsite fir inspections; if applicable. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 12/20/2021 Processing/Technology $25.00 12/20/2021 Inspection $75.00 12/20/2021 Air Cond. Unit $15.00 12/20/2021 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon EL16XC1 - 1.5 TO 5 TON AIR CONDITIONERS AI R CONDI TI ONE RS EL16XC1 ELITE® Series R-410A - 60 Hz Bulletin No. 210833 RESIDENTIAL July 2020 PRODUCT SPECIFICATIONS Supersedes May 2020 SEER up to 17.85 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION EL 16 X C 1 - 036 - 230 A 01 Product Tier Revision Level EL = Elite® Series Nominal SEER Ratings Revision Level 16 = 16 SEER Voltage Refrigerant Type 230 = 208/230V-1 phase-60hz X = R-410A Unit Type Nominal Cooling Capacity C = Air Conditioner (Condenser) 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons Cooling Stages 036 = 3 tons 1 = Single Stage Compressor 041 = 3.5 tons 042 = 3.5 tons Regional Standards 047 = 4 tons – (dash) = All Regions 048 = 4 tons S = Southeast and North Regions 060 = 5 tons FEATURE HIGHLIGHTS G B 1. Outdoor Coil Fan 2. Quantumâ„¢ Coil H 3. High Capacity Liquid Line Drier C 4. High Pressure Switch C 5. Scroll Compressor F 6. Heavy Gauge Steel Cabinet 7. SmartHingeâ„¢ Louvered Coil Protection 8. Refrigerant Line Connections and Access E D I CONTENTS Approvals And Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Controls - Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Dimensions - Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Electrical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Installation Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Optional Accessories - Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 TXV/Orifice Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 2 APPROVALS AND WARRANTY APPROVALS • AHRI Standard 210/240 certified • AHRI Certified system match-ups and expanded ratings, visit www.LennoxPros.com • ENERGY STAR® Certified (certain units) • Sound rated to AHRI Standard 270-2008 test conditions • Tested in Lennox’ Research Laboratory environmental test room • Rated According to U.S. Department of Energy (DOE) test procedures • Region specific models meet the minimum efficiency requirements for U.S. DOE Federal Regional Standards in that area • Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing • ETL certified (U.S. and Canada) • ISO 9001 Registered Manufacturing Quality System WARRANTY • Compressor: • Limited ten years in residential installations • Limited five years in non-residential installations • All other covered components: • Limited five years in residential installations • Limited one year in non-residential installations NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. FEATURES APPLICATIONS CQuantumâ„¢ Coil • 1.5 through 5 ton • Lennox designed and fabricated coil • Sound levels as low as 71 dBA • Enhanced aluminum alloy tube/enhanced fin coil • Single-phase power supply • Superior corrosion resistance • Vertical air discharge • Ripple-edged aluminum fins • Applicable to indoor air handlers or gas furnaces with • Aluminum tube construction indoor add-on coils • Lanced fins for maximum fin surface exposure • Shipped completely factory assembled, piped and wired • Fin collars grip tubing for maximum contact area • Factory test operated • Flared shoulder tubing connections REFRIGERATION SYSTEM • Factory tested under high pressure • Entire coil is accessible for cleaning R-410A Refrigerant • Non-chlorine, ozone friendly DHigh Capacity Liquid Line Drier • Unit is factory pre-charged • Factory installed in the liquid line • Drier traps moisture or dirt BOutdoor Coil Fan • Direct drive fan • 100% molecular-sieve, bead type, bi-flow drier • Vertical air discharge EHigh Pressure Switch • Totally enclosed fan motor • Protects the system from high pressure conditions • Sleeve bearings • Automatic reset • Inherently protected Discharge Thermostat • PVC (polyvinyl chloride) coated steel fan guard • Factory installed on the discharge line of the compressor • SPST • Automatic reset • Removes power to the compressor when discharge temperature exceeds the factory setting of 220ºF EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 3 FEATURES REFRIGERATION SYSTEM (continued) COMPRESSOR Refrigerant Flow Control FScroll Compressor • Units applicable to RFCIV METERING SYSTEM • High efficiency with uniform expansion valve ORIFICE BODY RFCIV suction flow systems or RFC (On Coil) ORIFICE • Constant discharge flow, high systems when volumetric efficiency and quiet matched with specific indoor coils LIQUID operation O−RING LINE • Low gas pulses during RFCIV: compression reduces operational LIQUID • Accurately meters LINE SCREEN sound levels refrigerant in SEAL • Compressor motor is internally system NUT SWEAT protected from excessive current • Refrigerant control CONNECTION and temperature is accomplished by exact sizing of refrigerant metering • Muffler in discharge line reduces orifice operating sound levels • The principle involves matching indoor coil with proper • Compressor is installed in bore size of orifice in metering device the unit on resilient rubber mounts for vibration free • Equalizes pressure shortly after compressor stops, unit operation starts unloaded Scroll Compressor Operation • Eliminates need for additional controls • Two involute spiral scrolls matched together generate a • Furnished with air conditioner series of crescent-shaped gas pockets between them Optional Accessories • During compression, one scroll remains stationary while the other scroll orbits around it Expansion Valve Kits • Gas is drawn into the outer pocket, the pocket is sealed • Field installed on certain indoor units as the scroll rotates • See TXV/Orifice Usage table • As the spiral movement continues, gas pockets are • Chatleff-style fitting pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced Freezestat • Senses suction line temperature • When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center • Cycles compressor off when suction line temperature of the fixed scrolls falls below it’s setpoint • During compression, several pockets are compressed • Opens at 29°F and closes at 58°F simultaneously resulting in a smooth continuous • Installs on or near the discharge line of the evaporator or compression cycle on the suction line • Continuous flank contact, maintained by centrifugal Loss of Charge Switch Kit force, minimizes gas leakage and maximizes efficiency • Protects compressor from damage from low refrigerant • Compressor is tolerant to the effects of slugging and charge conditions contaminants. If this occurs, scrolls separate, allowing • SPST, normally-closed liquid or contaminants to be worked toward the center and discharged • Automatic reset Compressor Crankcase Heater (060 Models) Refrigerant Line Kits • Protects against refrigerant migration that can occur • Refrigerant lines are shipped refrigeration clean during low ambient operation • Lines are cleaned, dried, pressurized and sealed at • Factory Installed factory Compressor Sound Dampening System • Suction line fully insulated • Polyethylene compressor • Lines are stubbed at both ends • 2 inch thick batt fiberglass insulation NOTE - Not available for -060 models. Must be field • All open edges sealed with one-inch wide hook and loop fabricated. fastening tape EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 4 FEATURES COMPRESSOR (continued) • Service Dashboard features online real-time monitoring of installed iComfort® thermostats Optional Accessories • High Definition Color Display with Subbase, Smart Hub Compressor Crankcase Heater (018 thru 048 models) Controller, wallplate (for retrofit installations) furnished • Protects against refrigerant migration that can occur for easy installation during low ambient operation • See the iComfort® E30 Smart Wi-Fi Thermostat Product Compressor Hard Start Kit Specifications bulletin for more information • Single-phase units are equipped with a PSC compressor Remote Outdoor Temperature Sensor motor • Used with the iComfort® E30 Smart Wi-FIiThermostat • This type of motor normally doesn’t need a potential • When installed outdoors, sensor relay and start capacitor allows thermostat to display outdoor • For conditions such as low voltage kit may be required temperature to increase the compressor starting torque • Sensor is auto-detected when Compressor Low Ambient Cut-Off Switch connected to thermostat • Non-adjustable switch (low ambient cut-out) prevents NOTE - Sensor is required for the compressor operation when outdoor temperature is Enhanced Dehumidification below 35°F Accessory (EDA). CONTROLS Thermostat • Thermostat is not furnished with unit Optional Accessories • See Lennox Price Book for selection iComfort® E30 Smart Wi-Fi Thermostat • Wi-Fi enabled, electronic 7-day, universal, multi-stage, Indoor Blower Off Delay Relay programmable, touchscreen thermostat • Delays the indoor blower-off time during the cooling cycle • 3 Heat/2 Cool • Auto-changeover Low Ambient Kit • Air conditioners can operate down to 45°F outdoor air • Controls dehumidification temperature without additional controls during cooling mode and humidification during • Allows unit to operate properly down to 30°F heating mode NOTE - Crankcase heater and freezestat should be • Offers enhanced installed on compressors equipped with a low capabilities including ambient kit. humidification / dehumidification / dewpoint ® NOTE - A compressor lock-out thermostat should be measurement and control, Humiditrol control, and added to terminate compressor operation below equipment maintenance reminders recommended operation conditions. • Easy to read 7 in. color touchscreen (measured diagonally) Compressor Timed-Off Control • LCD display with backlight shows the current and set temperature, time, inside relative humidity, system • Prevents compressor short-cycling status (operating mode and schedules) and outside • Allows time for suction and discharge pressure to temperature (optional outdoor sensor required) equalize • Smooth Setback Recovery starts system early to • Permits compressor start-up in an unloaded condition achieve setpoint at start of program period • Automatic reset with 5 minute delay between • Compressor short-cycle protection (5 minutes) compressor shut-off and start-up • Up to four separate schedules are available plus Schedule IQâ„¢ • One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away • Smart Awayâ„¢ - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving • Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets • Smart home automation compatible with Apple HomeKitâ„¢, Amazon Alexa®, Google Assistant and IFTTT EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 5 FEATURES CABINET G• Heavy-gauge steel construction • Pre-painted cabinet finish • Louvered heavy gauge steel panels surround unit on all four sides • Control box is conveniently located with all controls factory wired • Corner patch plate allows access to compressor components • Drainage holes are provided in base section for moisture removal • High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture PermaGuardâ„¢ Unit Base • Durable zinc-coated base section resists rust and corrosion HSmartHingeâ„¢ Louvered Coil Protection • Steel louvered panels provides complete coil protection • Panels are hinged to allow easy cleaning and servicing of coils • Panels may be completely removed • Interlocking tabs and slots assure tight fit on cabinet IRefrigerant Line Connections, Electrical Inlets and Service Valves • Sweat connection suction and liquid lines • Located on corner of unit cabinet • Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system • Refrigerant line connections and field wiring inlets are located in one central area of the cabinet • See dimension drawing EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 6 SPECIFICATIONS General Model No. All Regions EL16XC1-018 EL16XC1-024 EL16XC1-030 EL16XC1-036 Data Southeast and North Regions - - - - - - - - - EL16XC1S036 Nominal Tonnage 1.5 2 2.5 3 Connections Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.) - in. 3/4 3/4 3/4 7/8 Refrigerant 1 R-410A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs. 8 oz. 7 lbs. 1 oz. Outdoor Net face area - sq. ft. Outer coil 13.22 16.33 21.00 16.33 Coil Inner coil - - - - - - - - - 15.75 Tube diameter - in. 5/16 5/16 5/16 5/16 No. of rows 1 1 1 2 Fins per inch 26 26 26 22 Outdoor Diameter - in. 18 22 22 22 Fan No. of blades 3 3 3 3 Motor hp 1/10 1/6 1/6 1/6 Cfm 2290 3160 3160 3160 Rpm 1075 825 825 825 Watts 160 215 215 190 Shipping Data - lbs. 1 pkg. 155 171 187 205 ELECTRICAL DATA Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 2 Maximum overcurrent protection (amps) 20 25 25 30 3 Minimum circuit ampacity 11.9 14.6 17 18.0 Compressor Rated load amps 9.0 10.9 12.8 13.6 Locked rotor amps 48 59.3 67.8 79 Power factor 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps 0.7 1 1 1 Locked rotor amps 1.3 1.9 1.9 1.9 CONTROLS iComfort® E30 Smart Wi-Fi Thermostat 15S63 • • • • Remote Outdoor Temperature Sensor X2658 • • • • OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • • • • Compressor Hard Copeland 10J42 • • • • Start Kit LG 88M91 • • • • Compressor Low Ambient Cut-Off Switch 45F08 • • • • Compressor Timed-Off Control 47J35 • • • • Freezestat 3/8 in. tubing 93G35 • • • • 5/8 in. tubing 50A93 • • • • Indoor Blower Off Delay Relay 58M81 • • • • Loss of Charge Switch Kit 84M23 • • • • 4 Low Ambient Kit (Fan Cycling) 34M72 • • • • Refrigerant L15-41-20 L15-41-40 • • • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 7 SPECIFICATIONS General Model No. All Regions EL16XC1-041 EL16XC1-042 EL16XC1-047 EL16XC1-048 EL16XC1-060 Data Nominal Tonnage 3.5 3.5 4 4 5 Connections Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.) - in. 7/8 7/8 7/8 7/8 1-1/8 Refrigerant 1 R-410A charge furnished 9 lbs. 9 oz. 8 lbs. 12 oz. 11 lbs. 0 oz. 9 lbs. 12 oz. 12 lbs. 0 oz. Outdoor Net face area - sq. ft. Outer coil 21.00 21.00 22.17 21.00 29.09 Coil Inner coil 20.25 20.25 21.33 20.25 28.16 Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 No. of rows 2 2 2 2 2 Fins per inch 22 22 22 22 22 Outdoor Diameter - in. 22 22 26 22 26 Fan No. of blades 3 3 4 4 3 Motor hp 1/6 1/6 1/3 ¼ 1/3 Cfm 3050 3050 4400 3600 4550 Rpm 825 825 825 825 825 Watts 190 190 310 310 310 Shipping Data - lbs. 1 pkg. 227 234 272 255 284 ELECTRICAL DATA Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 2 Maximum overcurrent protection (amps) 30 40 35 40 50 3 Minimum circuit ampacity 19.3 23.4 21.9 24.2 29.6 Compressor Rated load amps 14.7 17.9 16.1 18.0 22.2 Locked rotor amps 75 112 105.5 117 127.9 Power factor 0.96 0.96 0.98 0.96 0.98 Outdoor Fan Motor Full load amps 1 1 1.8 1.7 1.8 Locked rotor amps 1.9 1.9 2.9 3.2 2.9 CONTROLS - ORDER SEPARATELY iComfort® E30 Smart Wi-Fi Thermostat 15S63 • • • • • Remote Outdoor Temperature Sensor X2658 • • • • • OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • • 93M06 • • Factory • Compressor Hard Copeland 10J42 • • Start Kit LG 88M91 • • • • • Compressor Low Ambient Cut-Off Switch 45F08 • • • • • Compressor Timed-Off Control 47J35 • • • • • Freezestat 3/8 in. tubing 93G35 • • • • • 5/8 in. tubing 50A93 • • • • • Indoor Blower Off Delay Relay 58M81 • • • • • Loss of Charge Switch Kit 84M23 • • • • • 4 Low Ambient Kit (Fan Cycling) 34M72 • • • • • Refrigerant L15-65-30 L15-65-40 • • • • Line Sets L15-65-50 Field Fabricate • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 8 SOUND DATA Octave Band Sound Power Levels dBA, re 10-12 Watts 1 Sound ² Estimated Sound Pressure Level at 1 Unit Center Frequency - HZ Rating Distance From Unit (dBA at distance in ft.) Model Number 125 250 500 1000 2000 4000 8000 3 5 10 15 50 (dBA) 018 55 61 67 68 63.5 59 50.5 72 65 60 54 51 40 024 55 62 67.5 66.5 63 59 52.5 72 65 60 54 51 40 030 54 61.5 66 66 62 57 51 71 64 59 53 50 39 036 56 66 69 67 62.5 57.5 50.5 73 66 61 55 52 41 041 54.5 62.5 67.5 67 62.5 58.5 52.5 72 65 60 54 51 40 042 55.5 62.5 68 67 62 57.5 51.5 72 65 60 54 51 40 047 55 62 67 66.5 62.5 57.5 49.5 72 65 60 54 51 40 048 55.5 64.5 70 71 65 60.5 54 75 68 63 57 54 43 060 55.5 62.5 67 66.5 62.5 60 53.5 73 66 61 55 52 41 NOTE - The octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING DISCONNECT DISCONNECT THERMOSTAT SWITCH SWITCH (Required) (By Others) (By Others) A B D A - Two Wire Power (not furnished) B - Two Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 18 ga. minimum D - Five Wire Low Voltage (not furnished). 18 ga. minimum C All wiring must conform to NEC or CEC and local electrical codes. LENNOX LENNOX AIR HEATING UNIT CONDITIONER OR AIR HANDLER UNIT INSTALLATION CLEARANCES NOTES: See NOTES Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) See See Clearance to one of the remaining two sides may be 12 in. (305 NOTES NOTES mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. (610 mm) must be maintained between two units. Control See NOTES Box 48 in. (1219 mm) clearance required on top of unit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 9 DIMENSIONS - UNIT SUCTION LINE CONNECTION LIQUID LINE TOP VIEW CONNECTION C (depth) B (width) DISCHARGE AIR LIQUID LINE CONNECTION ELECTRICAL A INLETS SUCTION LINE CONNECTION 2 (51) 4−3/4 4−1/4(108) (121) 1 (25) SIDE VIEW END VIEW UNIT SUPPORT UNIT SUPPORT FEET FEET 8−1/2 9−1/2 (216) (241) D K 8−3/4 8−1/4 (222) (210) E J 5−1/2 13−1/2 F G H (140) (343) EL16XC1-018 BASE SECTION EL16XC1-024 TO -060 BASE SECTION (Small Base) (Medium and Large Base) A B C D E F G H J K Model No. in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm EL16XC1-018 31 787 27 686 28 711 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EL16XC1-024 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-030 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-036 / 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1S036 EL16XC1-041 35 889 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-042 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-047 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 EL16XC1-048 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-060 45 114335-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 10 TXV/ORIFICE USAGE TXV SUBSTITUTION Use this table for C35, CH23, CH35 and CR33 Field A general guide for replacing the factory installed TXV if the Installed TXV/Orifice Match-Ups indoor unit (coil/air handler) is larger than the outdoor unit. Model No. Refrigerant Metering Thermal Outdoor Unit Indoor Unit TXV TXV Orifice (RFC) Expansion Furnished Replacement Size Tons Size Tons Valve (TXV) Order No. Orifice Size 024 2 38 3.5 12J19 12J18 EL16XC1-018 97M74 0.053 12J18 024 2 42 3.5 12J20 12J18 EL16XC1-024 97M75 0.057 12J18 024 2 48 4 12J20 12J18 EL16XC1-030 10W99 0.065 12J18 024 2 49 4 12J20 12J18 EL16XC1-036 11W02 0.073 12J19 030 2.5 38 3.5 12J19 12J18 EL16XC1S036 030 2.5 42 3.5 12J20 12J18 EL16XC1-041 97M77 0.074 12J20 030 2.5 43 3.5 12J20 12J18 EL16XC1-042 97M78 0.076 12J20 030 2.5 44/48 4 12J20 12J18 EL16XC1-047 10W86 0.080 12J20 030 2.5 48 4 12J20 12J18 EL16XC1-048 11W07 0.083 12J20 030 2.5 50/60 4 12J20 12J18 EL16XC1-060 10M13 0.097 12J20 TXV Ranges: CX35 and CHX35 coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. 12J18 - 1.5 to 2.5 ton systems - Use on 2.5 ton and lower If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table systems. by size. The correct TXV must be ordered separately and field installed. 12J19 - 3 ton systems - Use down to 2 ton systems. C35 and CH35 coils - Use the RFC orifice shipped with the outdoor unit or replace the factory installed RFC orifice with the expansion valve listed. 12J20 - 3.5 to 5 ton systems - Use down to 3 ton systems. CR33 and CH23 coils - Use the RFC orifice shipped with the outdoor unit or use the expansion valve listed. AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heatPower input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 11 REVISIONS REVISIONS Sections Description of Change Dimensions Updated for 036 model. Electrical Data Updated for 036 model. Specifications Updated for 036 model. Visit us at www.Lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2020 Lennox Industries, Inc.         !  "#$% !&'()*+ ,-$.% /0112'!*0(3'4 ,-$.,5566 78093:39!;+< ,-$.=>=?=@ A*1'0)*BCDE E >".$ 3F(+ G0'H)*1 I". JKJ JK  L- M3F(+9NO0112'G*0(3'4P92M ?$""QR"S HH (2*T3F(3'4!U *V&3WM*'( X-Y". P ?ZY[  %Y\"Q?"6  >".6Y$". ]$$Y.$^"Y _>"5 _66Y5 L`6 JE  ["  !  ?Y6 a8 ,66b.5" M*1*F300;)3F " 8019*)< HH1*FF*40)*F913W(32'a;'*10M* a;'*18G2'* c2'3'4 f !de JJD7EED  ! Ae Cc/!   >".$"6 2'(109(21813M01+ 2'(09(8G2'*HH1*FF 2'(109(21+W*39*'F* 39*'F*< /a!f h 78 A ad a JKJ JK  a JD 7J g  h8 !Ce a a /a!f h 78 A ad a /ag JKJ JK  /a! D g  h8 !Ce a a d _.6$".6 0(*'FW*9(32'+W**F913W(32'9G*H&)*H0(* 2MW)*(*H0(*'FW*9(21(0(&F          !"#       $%#&   %%$$   (""( )*+#",& '' ''      -). /001 2$%(#(#$)+# %$$(34%-"3, 56 $%#( 56 #+-8'9: (7 (# 5'6 #+-96 %- (% " $ )(#2 56 7(#7 ;(% 5 <=>?@ ABCCDEF G>>?HI0JK0>>0L1  # ##$%(#( '' MNOPQORSTUVWOX Y?Z[0\>1  # ( ,$%(#( ,)#4,%%# ,)+# ''' ]4 44;' 5' ''' )$(  ."($ 5 ^_>1>?\J`\ab?@?\H0 AFDFF c=>01  # #7 # ,d ''' +$($$"(%$%e()$(#" %()$(  ."($ '' +$($$"(%$f+(!e($$+ %g) ("$#')$(  ."($ '' ;(#" f+$#)$(  ."($ hi@=?J0J/`@01  # 2(" ) '' jklmnllopqlnorsOSRUQtuQv ''' jklqqjmmpqlnorsOXUTPwRtuRS '' jkllqqxypqlnorzuuPO{wXO|RtuQv '' jkllqqxopqlnorsuU{}tuQv