Loading...
HomeMy WebLinkAbout7216 Hawksview Dr_BLD4605_2025 ✔ 7216 HAWKSVIEW DR 18200.33 00898300000600 ✔ GAS FURNACE AND AC INSTALL DAWN OLLAR 4253300599 dawnollar@comcast.net 4253302599 7216 HAWKSVIEW DR ARLINGTON WA 98223 CM HEATING 4252590550 HHAGEAGE@CMHEATING.COM 4252590550 1500 INDUSTRY ST #200 EVERETT WA 98203 CMHEAI*095R4 05/2023 ✔ 1 15 4A7L6042A1000A 1 15 ADD2C100ACV52B 55.00 155.00 CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 7216 HAWKSVIEW DR Permit #: 4605 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00898300000600 DATE OF ISSUANCE. Scope of Work: Gas furnace and AC Install Valuation: .00 OWNER APPLICANT CONTRACTOR OLLAR TERRY L & DAWN R CM Heating CM Heating Inc 7216 HAWKSVIEW DR 1500 Industry St. #200 1415 Broadway ARLINGTON, WA 98223-4642 Everett, WA 98203 Everett, WA 98201 425-259-0550 425-259-0550 LIC: CMHEAI*095R4 EXP: 05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett, WA 98201 425-259-0550 LIC #: CMHEAI*095R4 EXP: 05/04/2023 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 4/6/2022 Signature Print Name Date Released By Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliances. Approved permit shall be onsite during installation. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 04/06/2022 Processing/Technology $25.00 04/06/2022 Inspection $75.00 04/06/2022 Air Cond. Unit $15.00 04/06/2022 Forced Air Heat $15.00 04/06/2022 Mechanical Base $25.00 Total Due: $155.00 Total Payment: $0.00 Balance Due: $155.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon        !"#$ %&&'( )*#+$  ,'-./0 )*#+)1122 3 /456-(7-89 )*#+:;:<:= >,(,--?@AB C ;!+# //' '0,'0, D!+  E AE F* GG'0,'0,HIJG,'-./08IKJ <#!!LM!N O'6P5(/'I,'/4/6-'&& Q*R!+ 8 <SRT $RU!L<!2 ;!+2R#!+ V##R+#W!R X;!1 X22R1 FY2 3  C  T! <R2 %Z )22[+1! ',&7//\K/,6 ! Z'(I,&9 44(,66,0'&,6I(.]-.K/%^/,('J, %^/,(ZGK/, _K/./0 3 O %cd BABC                $ !%&'()*+, !"# "# ## !"#0"# ## !"#0"# ##*(' +,12  ,$-(+ .-$/ 3 4  + 1 & 5" 5 6#7%    687% * "90 :; 1%( 607% * ":7 4 1< Submittal Side Discharge AC Models 4A7L6042A1000A Note: “Graphics in this document are for representation only. Actual model may differ in appearance.” TAG:______________________________ SAFETY WARNING Onlyqualifiedpersonnelshouldinstallandservicetheequipment.Theinstallation,startingup,andservicingofheating,ventilating,and air-conditioningequipmentcanbehazardousandrequiresspecificknowledgeandtraining.Improperlyinstalled,adjustedoraltered equipmentbyanunqualifiedpersoncouldresultindeathorseriousinjury.Whenworkingontheequipment,observeallprecautionsinthe literatureandonthetags,stickers,andlabelsthatareattachedtotheequipment. August 2017 4A7L6042A-SUB-1B-EN SAFETY SECTION Important — This document contains service CAUTION information. This is customer property and is to remain with this unit. Please return to service information pack CONTAINS REFRIGERANT! upon completion of work. Failure to follow proper procedures can result in personal illness or injury or severe equipment WARNING damage. HAZARDOUS VOLTAGE! System contains oil and refrigerant under high pressure. Recover refrigerant to relieve pressure Failure to follow this Warning could result in before opening system. property damage, severe personal injury, or death. CAUTION Disconnect all electric power, including remote disconnects before servicing. Follow proper GROUNDING REQUIRED! lockout/tagout procedures to ensure the power Failure to inspect or use proper service tools may cannot be inadvertently energized. result in equipment damage or personal injury. Reconnect all grounding devices. All parts of this WARNING product that are capable of conducting electrical current are grounded. If grounding wires, screws, REFRIGERANT OIL! straps, clips, nuts, or washers used to complete a Failure to follow this Warning could result in path to ground are removed for service, they must property damage, severe personal injury, or be returned to their original position and properly death. fastened. These units use R-410A refrigerant which operates at 50–70% higher pressures than R-22. Use only R- WARNING 410A approved service equipment. Refrigerant SERVICE VALVES! cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” Failure to follow this warning will result in abrupt tube to allow for charging of liquid refrigerant into release of system charge and may result in the system. All R-410A systems use a POE oil that personal injury and/or property damage. readily absorbs moisture from the atmosphere. To Extreme caution should be exercised when limit this “hydroscopic” action, the system should opening the Liquid Line Service Valve. Turn valve remain sealed whenever possible. If a system has stem counterclockwise only until the stem been open to the atmosphere for more than 4 contacts the rolled edge. No torque is required. hours, the compressor oil must be replaced. Never break a vacuum with air and always change the WARNING driers when opening the system for component replacement. For specific handling concerns with BRAZING REQUIRED! R-410A and POE oil, reference Retrofit Bulletin Failure to inspect lines or use proper service tools TRN-APG02–EN. may result in equipment damage or personal injury. CAUTION if using existing refrigerant lines make certain that HOT SURFACE! all joints are brazed, not soldered. May cause minor to severe burning. Failure to follow this Caution could result in property damage or personal injury. Do not touch top of compressor. ©2017IngersollRand 4A7L6042A-SUB-1B-EN Outline Drawing Model Base A B C D E F G H J 934 1194 445 20 8 53 187 101 159 4A7L6042A 4.3 (36–3/4) (47) (17–1/2) (25/32) (5/16) (2–1/16) (7–11/32) (3–31/32) (6–1/4) SOUND POWER LEVEL A-WeightedSound FullOctaveSoundPower[dB] Model PowerLevel[dB(A)] 63Hz* 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 4A7L6042A 73 56 77 76 71 67 62 56 48 Note:RatedinaccordancewithAHRIStandard270–2008*Forreferenceonly 4A7L6042A-SUB-1B-EN 3 Product Specifications OUTDOORUNIT(a)(b) 4A7L6042A1000A (a) CertifiedinaccordancewiththeAir-SourceUnitaryAir-conditioner HIGHSPEEDCOOLINGCAPACITY@ Equipmentcertificationprogram,whichisbasedonAHRIstandard 80/67-95(Btuh) 41000 210/240. (b) RatedinaccordancewithAHRIstandard270. POWERCONNS.—V/PH/HZ(c) 208/230/1/60 (c) CalculatedinaccordancewithNatl.Elec.Codes.UseonlyHACR MIN.BRCH.CIR.AMPACITY 22 circuitbreakersorfuses. (d) ThisvalueshownforcompressorRLAontheunitnameplateandon BR.CIR.PROT.RTG.—MAX.(AMPS) 35 thisspecificationsheetisusedtocomputeminimumbranchcircuit COMPRESSOR DURATION®-SCROLL ampacityandmax.fusesize.Thevalueshownisthebranchcircuit selectioncurrent. NO.USED—NO.STAGES 1—1 (e) Nomeansnostartcomponents.Yesmeansquickstartkit VOLTS/PH/HZ 208/230/1/60 components. (f) StandardAir—DryCoil—Outdoor R.L.AMPS(d)—L.R.AMPS 16.7—109 (g) Thisvalueapproximate.Formoreprecisevalueseeunitnameplate. FACTORYINSTALLED (h) Max.linearlength150ft.;Max.lift—Suction50ft.;Max.lift—Liquid 50ft.ForgreaterlengthconsultrefrigerantpipingsoftwarePub.No. STARTCOMPONENTS(e) NO(UsesBAYKSKT263) 32–3312–0*(*denoteslatestrevision). INSULATION/SOUNDBLANKET NO COMPRESSORHEAT NO OUTDOORFAN PROPELLER DIA.(IN.)—NO.USED 27—1 TYPEDRIVE—NO.SPEEDS DIRECT—1 CFM@0.0IN.W.G.(f) 3800 NO.MOTORS—HP 1—1/5 MOTORSPEEDR.P.M. 850 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 1.18 OUTDOORCOIL—TYPE PLATEFIN ROWS—F.P.I. 2—16 FACEAREA(SQ.FT.) 12.88 TUBESIZE(IN.) 5/16 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 6LBS.,14OZ FACTORYSUPPLIED YES LINESIZE—IN.O.D.GAS(h) 3/4 LINESIZE—IN.O.D.LIQ. 3/8 CHARGINGSPECIFICATIONS SUBCOOLING 10°F DIMENSIONS HXWXD CRATED(IN.) 40.88x54.5x23.0 WEIGHT SHIPPING(LBS.) 243 NET(LBS.) 216 4 4A7L6042A-SUB-1B-EN Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature and for up to 15 feet of piping. This unit is designed to pressure protection. Other features include: Centrifugal operate at outdoor ambient temperatures as high as oil pump and low vibration and noise. 115°F. Cooling capacities are matched with a wide Condenser Coil selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is The aluminum plate fin, copper tube outdoor coil designed for outdoor application. provides low airflow resistance and efficient heat transfer. The coil is protected with a corrosion resistant Casing mesh coil guard. Unit casing is constructed of heavy gauge, galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All As manufactured, this system has a cooling capacity to panels are subjected to our 1,000 hour salt spray test . 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an Refrigerant Controls evaporator defrost control with TXV permits low Refrigeration system controls include condenser fan, ambient cooling to 30°F. compressor contactor and low and high pressure The addition of the BAYLOAM107A low ambient kit switches. A factory supplied, field installed liquid line permits ambient cooling to 20°F. drier is standard. Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. 4A7L6042A-SUB-1B-EN 5 Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com IngersollRandhasapolicyofcontinuousproductandproductdataimprovementsandreservestherighttochangedesignandspecifications withoutnotice. Wearecommittedtousingenvironmentallyconsciousprintpractices. 4A7L6042A-SUB-1B-EN 04Aug2017 Supersedes4A7L6042A-SUB-1A-EN (March2017) ©2017IngersollRand