Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6707 Upland Dr_BLD4808_2025
CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 6707 UPLAND DR Permit #: 4808 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00870600004900 DATE OF ISSUANCE. Scope of Work: Furnace replacement Valuation: 6238.49 OWNER APPLICANT CONTRACTOR MACDONALD AARON & DIANE WestWorld Air WestWorld Air 4014 168TH ST NE PO Box 1656 PO Box 1656 ARLINGTON, WA 98223 Gig Harbor, WA 98335 Gig Harbor, WA 98335 360-990-4346 360-990-4346 LIC: WESTWAL802LA EXP: 05/18/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR WestWorld Air PO Box 1656 Gig Harbor, WA 98335 360-990-4346 LIC #: WESTWAL802LA EXP: 05/18/2024 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. Annie Westlund 06/23/2022 6/22/2022 Signature Print Name Date Released By Date CONDITIONS Adhere to approved appliance. Approved permit shall be onsite during installation. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/22/2022 Processing/Technology $25.00 06/22/2022 Inspection $75.00 06/22/2022 Forced Air Heat $15.00 06/22/2022 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon CITY OF ARLINGTON 18204 59th Avenue NE, Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 6707 UPLAND DR Permit #: 4808 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 00870600004900 DATE OF ISSUANCE. Scope of Work: Furnace replacement Valuation: 6238.49 OWNER APPLICANT CONTRACTOR MACDONALD AARON & DIANE WestWorld Air WestWorld Air 4014 168TH ST NE PO Box 1656 PO Box 1656 ARLINGTON, WA 98223 Gig Harbor, WA 98335 Gig Harbor, WA 98335 360-990-4346 360-990-4346 LIC: WESTWAL802LA EXP: 05/18/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR WestWorld Air PO Box 1656 Gig Harbor, WA 98335 360-990-4346 LIC #: WESTWAL802LA EXP: 05/18/2024 LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington #3101. 6/22/2022 Signature Print Name Date Released By Date CONDITIONS Adhere to approved appliance. Approved permit shall be onsite during installation. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/22/2022 Processing/Technology $25.00 06/22/2022 Inspection $75.00 06/22/2022 Forced Air Heat $15.00 06/22/2022 Mechanical Base $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested, and whether you prefer morning or afternoon GMVC80(A) / GCVC80(A) Heating Input: 60,000–100,000 BTU/h Two-Stage, Variable-Speed ECM Gas Furnace 80% AFUE Contents Nomenclature ........................................2 Product Specifications ...........................3 Dimensions ............................................5 Airflow Data ...........................................7 Accessories ............................................8 Wiring Diagram ...................................10 Standard Features Cabinet Features • Integrated communicating ComfortBridgeâ„¢ technology • Fully insulated, heavy-gauge steel cabinet • Two-stage gas valve provides quiet, with durable baked-enamel finish economical heating • Multi-position installation: • Commissioning and diagnostics via on board GMVC80: upflow, horizontal left or right Bluetooth with the CoolCloudâ„¢ phone and GCVC80: downflow, horizontal left or right tablet application • Removable bottom for side- or • Efficient and quiet variable-speed ECM bottom-return applications circulator motor gently ramps up or down • Convenient left or right connection according to heating or cooling demand for gas/electric service • SureStart® Silicon Nitride igniter • Cabinet air leakage ≤ 2% designed for long igniter life • Coil and furnace fit flush • Self-diagnostic control board with constant memory for most installations fault code history output to a triple 7-segment display • Low constant fan speed circulates air throughout the home • Quiet, two-speed induced draft blower • California Low NOx emissions-compliant models available • For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the SCAQMD Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. • AHRI Certified; ETL Listed * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-GMVC80/GCVC80 www.goodmanmfg.com 6/19 Supersedes 4/19 Nomenclature G M V C 80 040 4 C * ** 1 2 3 4 5,6 7,8,9 10 11 12 13,14 Brand Engineering G - Goodman® Brand Major /Minor Revisions * Not used for inventory control. Configuration NOx M - Upflow/Horizontal N - Natural Gas C - Downflow/Horizontal X - Low NOx Motor Cabinet Width V - Variable Speed ECM / ComfortBridgeâ„¢ A - 14" C - 21" E - Multi-Speed ECM S - Single Speed B - 17½" D - 24½" Gas Valve Maximum CFM M - Modulating S - Single Stage 2 - 800 CFM 4 - 1600 CFM C - Two Stage H - Convertible Single Phase 3 - 1200 CFM 5 - 2000 CFM AFUE MBTU/h 80 - 80% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h 060 - 60,000 BTU/h 120 - 120,000 BTU/h 080 - 80,000 BTU/h 2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3 Specifications GMVC80 GMVC80 GMVC80 GMVC80 GMVC80 GMVC80 GMVC80 0603B*A 0604B*A 0803B*A 0804C*A 0805C*A 0805D*A 1005C*A Heating Capacity High Fire Input (BTU/h)¹ 60,000 60,000 80,000 80,000 80,000 80,000 100,000 High Fire Output (BTU/h)¹ : Natural Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000 LP Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000 Low Fire Input (BTU/h)¹ 42,000 42,000 56,000 56,000 56,000 56,000 70,000 Low Fire Output (BTU/h)¹ : Natural Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 LP Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 AFUE² 80 80 80 80 80 80 80 Available AC @ 0.5†ESP 1.5 - 3.0 1.5 - 4.0 1.5 - 3.0 3.0 - 4.0 2.0 - 5.0 2.5 - 5.0 2.0 - 5.0 Temperature Rise Range (° F) 15-45 / 15-45 20-50 / 20-50 30-60 / 35-65 25-55 / 20-50 20-50 / 20-50 20-50 / 30-60 25-55 / 25-55 Circulator Blower Size (D x W) 10†x 8†10†x 8†10†x 8†11" x 10" 10†x 10†11" x 10" 10†x 10†Horsepower - RPM 1/2 3/4 1/2 1/2 3/4 3/4 3/4 Speed Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter¹ 4†4†4†4†4†4†4†No. of Burners 3 3 4 4 4 4 5 Electrical Data Min. Circuit Ampacity³ 7.75 10.6 7.75 7.75 10.6 10.6 10.6 Max. Overcurrent Device (amps)4 15 15 15 15 15 15 15 Ship Weight (lbs) 105 107 110 118 121 129 124 ¹ Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high-fire rate. ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. â´ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½†FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3 Specifications GCVC80 GCVC80 GCVC80 GCVC80 0603B*A 0803B*A 0805C*A 1005C*A Heating Capacity High Fire Input (BTU/h)¹ 60,000 80,000 80,000 100,000 High Fire Output (BTU/h)¹ Natural Gas 48,000 64,000 64,000 80,000 LP Gas 48,000 64,000 64,000 80,000 Low Fire Input (BTU/h)¹ 42,000 56,000 56,000 70,000 Low Fire Output (BTU/h)¹ Natural Gas 33,600 44,800 44,800 56,000 LP Gas 33,600 44,800 44,800 56,000 AFUE² 80 80 80 80 Available AC @ 0.5†ESP 1.5 - 3.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0 Temperature Rise Range (° F) 25-55 / 40-70 30-60 / 30-60 25-55 / 30-60 20-50 / 25-55 Circulator Blower Size (D x W) 10†x 8†10†x 8†10†x 10†10†x 10†Horsepower - RPM 1/2 1/2 3/4 3/4 Speed Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter² 4†4†4†4†No. of Burners 3 4 4 5 Electrical Data Min. Circuit Ampacity³ 7.75 7.75 10.6 10.6 Max. Overcurrent Device (amps)â´ 15 15 15 15 Ship Weight (lbs) 105 109 125 129 ¹ Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 70% of high- fire rate. ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. â´ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½†FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5 GMVC80 Dimensions Alternate Gas Inlet Alt. Flue Outlet — Horizontal Left 1¾†A 17â„16†➤ B 19½†➤ ➤ 33⅜†Alt. Gas Inlet 27⅞†20†➤ 235â„16†Alt. High Voltage High-Voltage Inlet 13¼†15†Low-Voltage Inlet Alt. Low Voltage ➤ ➤ 23†➤ 28†Dimensions Heights Model W D H A B GMVC800603B** 17½†28†33â…œ" 17½†16†GMVC800604B** 17½†28†33â…œ" 17½†16†GMVC800803B** 17½†28†33â…œ" 17½†16†GMVC800804C** 21†28†33â…œ" 21†19½†GMVC800805C** 21†28†33â…œ" 21†19½†GMVC800805D** 24½†28" 33â…œ" 24½†23" GMVC801005C** 21†28†33â…œ" 21†19½†Minimum Clearances to Combustible Materials Vent Sides Rear Front Bottom Top SW B 1 0 3 C 6 1 1 C = If placed on combustible floor, the floor MUST be wood ONLY. Notes: • For servicing or cleaning, a 24†front clearance is recommended. • Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. • In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. • Refer to the appropriate USA and Canadian codes: ͵ In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 ͵ In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5 GCVC80 Dimensions 28†A 19â…†B High-Voltage Electrical Low-Voltage Electrical Gas Inlet 33⅜†18⅜†11⅜†Dimensions Heights Model W D H A B GCVC800603B** 17½†28†33â…œ" 17½†16†GCVC800803B** 17½†28†33â…œ" 17½†16†GCVC800805C** 21†28†33â…œ" 21†19½†GCVC801005C** 21†28†33â…œ" 21†19½†Minimum Clearances to Combustible Materials Vent ² Sides Rear Front ¹ Top SW B 1 0 3 6 1 1 Approved for line contact in the horizontal position. ¹ 24†clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. 6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7 Airflow Data MODEL/TEMP RISE RANGE GCVC800603BXA* GCVC800603BXA* GCVC800805CXA* GCVC801005CXA* GMVC800603B*A* GMVC800604B*A* (MID RISE) 25-55 (40) 30-60 (45) 25-55 (40) 20-50 (35) 15-45 (30) 20-50 (35) CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE Recommended cfm for high heat / 1100 40 1325 45 1470 40 2090 35 1400 32 1275 35 expected temperature rise Lowest recommended cfm for hi heat / 810 55 990 60 1070 55 1475 50 980 45 890 50 expected temperature rise Maximum cfm for hi heat / expected 1400 32 1400 42 2200 27 2200 34 1400 32 1760 25 temperature rise NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5% 0140F02402-A MODEL/TEMP RISE RANGE GMVC800803B*A* GMVC800804C*A* GMVC800805C*A* GMVC800805D*A* GMVC801005C*A* (MID RISE) 30-60 (45) 25-55 (40) 20-50 (35) 20-50 (35) 25-55 (40) CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE Recommended cfm for high heat / 1330 45 1400 42 1700 35 1700 35 1850 40 expected temperature rise Lowest recommended cfm for hi heat / 980 60 1090 54 1175 50 1175 50 1350 55 expected temperature rise Maximum cfm for hi heat / expected 1400 42 1760 34 2200 27 2200 27 2200 34 temperature rise NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5% 0140F02402-A GCVC800603BXA, GCVC800803BXA GMVC800604B*A GMCV800603B*A, GMVC800803B*A GMVC800804C*A Cooling Speed Cooling Speed ( @ .1†- .8†w.c. ESP) ( @ .1†- .8†w.c. ESP) Low-Stage Low-Stage Tons High-Stage Tons High-Stage CFM CFM 1.5 600 420 2 800 560 2 800 560 2.5 1,000 700 2.5 1,000 700 3 1,200 840 3 1,200 840 4 1,600 1120 MAX 1,400 MAX 1,760 GMVC800805C*A, GMVC800805D*A GCVC800805CX*A GMVC801005C*A GCVC801005C*A Cooling Speed Cooling Speed ( @ .1†- .8†w.c. ESP) ( @ .1†- .8†w.c. ESP) Low-Stage Low-Stage Tons High-Stage Tons High-Stage CFM CFM 2 800 560 2 800 560 3 1,200 840 3 1,200 840 4 1,600 1,120 4 1,600 1,120 5 2,000 1,400 5 2,000 1,400 MAX 2,000 MAX 2,200 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5†w.c. ESP in heating mode. Operating CFM between .5†and .8†w.c. is tabulated for cooling purposes only. 6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7 Airflow Data (cont.) GCVC Continuous Fan Speeds Furnace Continuous Model Maximum CFM Fan Speed GCVC800603BXBX 1,400 350-1,400 GCVC800803BXBX 1,400 350-1,400 GCVC800805CXBX 2,200 550-2,200 GCVC801005CXBX 2,200 550-2,200 GCVC8 Minimum Filter Sizes Model # GCVC800603BX, GCVC80803BX GCVC800805CX GCVC801005CX Filter Size (in²) (2) 10 x 20 or (1) 16 x 25 (Top Return) (2) 14 x 20 or (1) 20 x 25 (Top Return) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. GMVC Continuous Fan Speeds Furnace Continuous Model Maximum CFM Fan Speed GMVC800603B*A 1400 350 - 1400 GMVC800604B*A 1760 440 - 1760 GMVC800803B*A 1400 350 - 1400 GMVC800804C*A 1760 440 - 1760 GMVC800805C*A 2200 550 - 2200 GMVC800805D*A 2200 550 - 2200 GMVC801005C*A 2200 550 - 2200 GMVC8 Minimum Filter Sizes GMVC800604B*, GMVC800603B*, GMVC800805C*, GMVC800804C*, Model # GMVC801005C* GMVC800803B* GMVC800805D* Filter Size (in²) (1) 16 x 25 (Side or Bottom) (1) 16 x 25 (Side or Bottom) ¹ (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. Accessories Model Description LPM-06 LP Conversion Kit (Springs & Orifice) ¹ AM11-1425-FA AM11-1625-FB Deep Pleated Media Air Cleaner AM11-2025-FC AM11-2525-FD ¹ White-Rodgers and Honeywell valves 8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9 Temperature Rise Range Chart ÷ CFM 130 140 150 Formulas1.08CFM x 1.08 FORMULASBTU/H Output BTU OUTPUT BTU/h Output = CFM x 1.08 x RiseRise = BTU OUTPUT = CFM x 1.08 x RISERISE = 110 120 100 2400 CFM 2200 2000 1800 1600 1400 1200 1100 Output BTU/h x 1,000 OUTPUT BTU/HR x 1000 1000 900 BTU Output Vs. Temperature Rise Chart800 BTU OUTPUT vs TEMPERATURE RISE CHART700 600 CFM 30 40 50 60 70 80 90 90 80 70 60 50 40 30 20 10 100 Temperature RiseTEMPERATURE RISE 8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9 Wiring Diagram TO GND 115VAC/1Ø/60 HZ POWER SUPPLYWITH YLYL JUNCTION BOX OVERCURRENT BL PROTECTIONDEVICE IDBLOWERTWO-STAGEPRESSURE WH BR L SWITCHASSEMBLY WARNING:DISCONNECT YLBL POWER BEFORE HOT BK LOWFIRE N SERVICING. WIRING SURFACE YL TO UNIT MUST BE IGNITER PRESSURE WH C PROPERLYPOLARIZED 2 CIRCUIT SWITCH C DISCONNECT AND GROUNDED. 2 1 CONNECTOR NO NO TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH BK OVERCURRENT PROTECTION DEVICE WH TWOSTAGE HIGHFIRE L GND N GASVALVE PRESSURESWITCH WARNING: FLAME (WHITE-ROGERS) DISCONNECT POWER YL SENSOR BEFORE SERVICING. HI WH WIRING TO UNIT âš¡ C BL MUST BE PROPERLY POLARIZED AND GROUNDED. DISCONNECT M BR BL CHASSIS GROUND MANUALRESETROLLOUT LIMIT CONTROLS DOOR PU BL PU OR SWITCH JUNCTION BOX AUTO RESET PRIMARY LIMIT CONTROL INDUCTORCOIL (ONSOME MODELS) BR INDOOR AIR INDUCED CIRCULATOR WH 3 WH DRAFT GN BLWR RD 2 RD BLOWER BK GND 1 BK LINE NEUTRAL BURNERCOMPARTMENT GND INTEGRATED CONTROL MODULE INTEGRATED CONTROL MODULE BLOWERCOMPARTMENT AUTORESET PK AUXILIARYLIMIT CONTROL(TWOON PU SOMEMODELS) EAC ELECTRONIC NEUTRAL AIR CLEANER IND HI NEUTRAL ID EAC BLWR FS NEUTRAL NEUTRAL WH IGN INDLO LINE BK BK HOTSURFACE WH OR BK FS IGNITER WH FLAMESENSOR 4 CIRCUIT MOTOR LINE 115VAC NEUTRAL CONNECTOR 4 WH 40VA 3 5 CIRCUIT CONNECTOR FUSE3A TH(4) TRANSFORMER BL R 24VAC AUTORESETPRIMARY 2 GN 5 WHRD BK BL AUTORESETAUXILIARYLIMIT LIMITCONTROL 1 4 CONTROLS(TWOONSOMEMODELS) YL 24V THERMOSTAT CONNECTIONSTO+VDC Disconnect all power before servicing or installing this unit. Multiple power WH 3 Y HLO(10) BK BL MODULECONTROL 2 RD AUXIN(3) BR 13 14 15 1 24 PSO (7) LOWFIRE PK VAC PRESS. 10 11 12 W PS1 (2) SWITCH YL 115 NO C 7 8 9 VAC High Voltage:sources may be present. Failure to do so may cause property damage, personal injury, or death. RD BK PS2 (12) NO 4 5 6 40VA WH TO BL 24V HIGHFIRE C TRANSFORMER MICRO 1 2 3 BR 3A PRESS. SWTICH YL DIAGNOSTIC ROLLOUTSWITCHIN(6) MANUALRESETROLLOUT PU G FUSE LED'S LIMITCONTROLS HLI(1) LED THERMOSTAT MVL(13) M 2 R1 C R WC YG DE-HUM MVC(8) RJ12 C Warning BK CABLE C MVH(14) HI RD BL GAS ECM MTR GY GND(5) VALVE HARNESS BK TR(11) GND âš BK 4 TO 3 BK GND(4) 2 5 BK R 1 4 WH +VDC(1) 3 GR 2 RX(2) INDOOR 1 PK GND BLOWER AIR TO CIRCULATOR COMPARTEMENT MICRO TX(3) BLWR DOOR SWITCH (OPEN WHEN DOOR OPEN) CIRCULATOR INDUCTORCOIL INTEGRATEDCONTROL MODULE BLOWER (ONSOME MODELS) NOTES: COLOR CODES: 1. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN LOW VOLTAGE (24V) EQUIPMENT GND SERVICING. PK PINK 2. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE LOW VOLTAGE FIELD FIELD GND REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A BR BROWN TEMPERATURE RATING OF AT LEAST 105° C. USE COPPER CONDUCTERS WH WHITE HI VOLTAGE (115V) FIELD SPLICE ONLY. BL BLUE HI VOLTAGE FIELD GY GRAY SWITCH (TEMP.) RD RED JUNCTION Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. YL YELLOW IGNITER TERMINAL OR ORANGE PU PURPLE INTERNAL TO SWITCH (PRESS.) INTEGRATED CONTROL GN GREEN OVERCURRENT BK BLACK PLUG CONNECTION PROT. DEVICE 0140F02445-A Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2019 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 10 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com PB ✔ 6707 Upland Drive 6238.49 49 00870600004900 ✔ Furnace Replacement HPA LLC 3609904334 bwestlund@westworldair.com 3609904334 P.O. Box 1656 Gig Harbor WA 98335 WesrWorld Air 3609904346 Awesrlund@westworldair.com 3609904334 P.O. Box 1656 Gig Harbor WA 98335 WAETWAL802LA 5/18/2024 ✔ 1 15.00 140.00 !"#$ % &'#($ )*+,)-./01. &'#(&2233 %45-678 &'#(9:9;9< =1> ?.@-.A)B CC8 :!(# 5-)*+,/DE0 F!( C GBB G C H' ?I*+,/DE0JI*+,I-./0?1.KL-M ;#!!NO!P QD.E?L*.*R/?L*M*E, S'T!( C K B ;UTV $TW!N;!3 :!(3T#!( X##T(#Y!T Z :!2 Z33T2 C H[3 77B V! ;T3 \% &33](2! ?*/^EE_-E*+ ! %?.L*/` 00.*++*>?/*+L.1R,1-E4IE*.?M* 4IE*.%a-E* b-E1E> 7 = 4 c B !"#$%&'&& ( !)*+,-+ +./ 0 1 0 233 4567869:;<=>6? @!AB+C / 0 D0 D ED D 23F3 GH I J KL / !C,MCNO!"!C)+ #&'&& P +/ 0 Q H DI 233 R ST DU 233 VWXHY2FQT DU Z["!,+,\M"+/ 0 Q 233 ]^_`]abacbc^_de;fdg<h68<9?6i7j<kli96ki7mn8o