HomeMy WebLinkAbout17716 48th Dr Ne_BLD762_2026 I 5 III III GENERAL NOTES I.ALLGRODVED COUPLIN(A9 TO BE RIpOTYPE UNLEB8 N01E00111ER'MBE ABBATARE HANGER #10 4 ALLSTEELRPETOBEASFOLLOWS: I 1 m��EN a�,x1r�. lw:wPDRk o T I aIM ,�. TxR�m.GmkRDLLYwDWDFwxEw.wLRNm !Am Le¢numoErwax REETl ane �y I,p o,IPo im ixFanm,Gn.xouonooum.vl.VNEw,Wuq+m lce b O0'.in,PwxmO.Pcuexm en! v a.,x van TIFB1oEawrAwuaaorm,Pwxex6,wuwm NIN P ENP­ wl-E _ wI � END NDI FN1� 1 FLANGE LOCATION PLAN eNe P«DmDED. xWo' ' l b �N ® 8.MANMUM DISTANCE BETYEEN MANOEFB TO BEAK ROLLOWs: i I xOMxeARPlela a♦ t IRO Ite v etN a ♦ 0 e nEELM1R xM IRO IPo ,m Iw ,60 IeA IXe IRO IN 1\ SCOPE OF WORK i 0 5 FlRxn3wrt _____ COMMERCIAL FIRE PROTECTION M IPI MROFMOEONE WEf PIPEAUTOMATIC FIRE �..--�_ _ _ e• ¢rx YWY SYSTEM TOPROTECTTHE HEATED INTEROROFTNE BLRLCiNO. �nmxlaM OFPWILL BENNWORKINBIDETHENNLDINGATAGSUPPLYFUANGELETRAMINMUe �+ ABOVE THE FINISHED FLOOR BY OTHERS CLARIFICATIONS r I 1.KLAgEABPROTEOTEDWAWETSVSTEMMUBTBEMAINTAINED OTHERSATA r_...._�� -...-_.i I... _.. '}'�• aF® h OF 1TOPREYENTFREEZING. II i 2.CFPABSUMESTHE9RULTURETOBEADEOUATETOBUPPORITHESPRNNERS EXCLUSIONS bl I 1.PAINTN.OFIABEUNGOFWRINIGER RRNOAND/OREOVIPMENT 4.EUECTFIOALWIRINGOFANYIGND. I *MP —�1y/ICENRW.aTATON AWiM EOUIFMENi,WTRINp,ANO MONITOPoNO. IY a YTHA�eNOTF�MTIONDWOES IB)ROBES,BELIE,ETC)TO BE SUPPLIED MD INST E S.UNDERGROUNDWORKOF 14D. B.EPRNILBR PROTECTION OF—ERIOR NONCOMBUSTINEC ' b b ANOPIFS. I 4 EXISTING BUILDING — d "© ' R DESIGN CRITERIA N.I.C. .�..� I � U A PER NFPA 404-E011 EDINON INSTAUATON OF SPPoNNERSYHIEAIB { io6J T Q AIRCRAFTHANGER Z F.vNe / GROUP IINRCMFf HANGAR .1)GPM/RO.FL.OYER6 BECTON)4CLOBEDHEADWATER SPRINKLER SYSTEM FOR AIRCRAFT STORWE AND N °•.♦i ° 6EMMONG MEAS SITE PLAN PERNFPA13 2013EDMONINSTAUATONOFSPRNNERSra)EMS PRODUCTION/A99EMBLY/REPAIR SYSTEM#1 DATA Y nmxin°� �PulaMux4PR e�1` aRD NARr HAu,NDLROugn .m 11PM/sG.Fr.OVER 11 xue,-w AREADESDPoPTION AEASO.ROOTAGE NO.OPSPRNNIERS ENTIRE BUILDING 1e,zoU so.Fr, soz OFFICES TTDTAL 19,2WRO.FT, uDH,—" .16GFM/aD.Fr.aYERu WATER SUPPLY DATA 4az RISER ELEVATION s8.28.1 ALLOWa FORA—REDUCTION INTHE DESIGN AREA WITHOUT HYDRAULIC CALCULATION DATA TOENSITY WXERE USTED OUICWRESRONSE SPRINGERS ARE USED FOR CEIUNOB BTATO &PSI DESIGNDENIBTY 7GPM/SG.FT.DVERN10080.Fi. ® UP T010 FT. � DEMA4DAT0ITYCONNECTION.14 GPMATeBASPBI elvvlA+lx/ FIN&DESON DENSITY .100PM/BO.Ff.OVERl RESIDUAL m.1 INCWDE56000PMRORTOYALHOSEAL NOE FIAVANG mD0 GM OATH PROVOED BYTHE CRYOFARUNGTON RISER EQUIPMENT LIST REM OW SIZE DESCRIPTSKx MANUFACTURER MODEL CITY OF AUINGTI z i wuBP oe NECTORCXECKvuvEASBEMeIr DICATOR ari DA BcvORG BUILDING DEPARTMEId'tt 31 1R' VALVESUPOMSORYSYATCH POT}ERELECIRD PCVa2 APPROVED WATERFLONSWRCH ROTTERELECIgO VSR Q Q Q e GLO t4. SWINDCHTESTANPHEBBUREQWOE ALP FCVV a..:,w..u.w.po,•e.�.ti.�� T 1 — BWINGECKVALVE BE mtA y}�F((,(1r�L2^^_O■ k PB'n4.6'xA' FIgE OEPARIMENT CONNECTION GUMDMN 9 DC WALL PIATE GUMDVN Rasa 10 tY HEM aPMEXEAO CABINET TYOO NO CHANGER AUTHORIZED UNLESS APPROVED BY THE aPNE sPRINKIERs a wRENaee BUILDING INSPECTOR RMNUFALTURER BMY TYK MODEL FINISH WFACTOR THREaD TEMP OTV wnm,w n � VINNB VO00 8Su Bq N M B E _ND VMm2 BBP OR WRITE SA 118' 13Y 2 D VINNp MODEL IORe eRTINIGER WRENCH 111WEOTON M era i FIRE PROTECTION 8PR NN OFFICE COPY Mike NI W BUILDING SECTION ;COMM DJJLLLY�^ 1 CDmL0100 Fire LIMBS Stl0n,IN 1 COIAMEFP132MM 1 HANGER LEG D apmINKLEIN LEGEND ABBREVIATIONS I SYMBOL LEGEND REVISONS eOmMm vrtm FP COMMERCI%IRlE kTnumUNE 1x elate ReFE"°' ABBATARE,INC. 176174BTH AVENUE NE Receive ucEi ei�1. k. ! ARLINGTON.WA MISSIxlDxe ro�°'°'°°n "°'•' —�" PRO.IECTMANAGER:HANSVONDER NOFFEN AUG 12 2015 ABBATARE HANGER NO.10 a 'f"„xe"E'°NW ry RKm PHoNEA. <.1- Q xwwuw cucuuTNx xoo! eUPERI 03'xTa-1eTe 17716 MTH DRIVE ✓♦�:. ARLINGTON.WA SSW 1 vNE NQlDCQWUNQ AUTHORITY HAVING JURISDICTION:CITY OF ARLINGTON I F": 1m WAIT M1NE wNTGN aG116 -_--_� -__-- / FIRE PROTECITON SPRINKLE ' CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 1771648th Dr Perm it#:762 Parcel#:31052100400104 Valuation:60000.00 OWNER APPLICANT CONTRACTOR Name:ARLINGTON CORPORATE AIR PARK Name:Commercial Fire Protection,Inc Name:Commercial Fire Protection,Inc Address: 17617 49TH PL NE HANGER B Address:17199 Bennett Rd Address: 17199 Bennett Rd City,State Zip:ARLINGTON,WA 98223 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-848-9093 ext 122 Phone:360-848-1533 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2012 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI 10. LES TAX N I ICE:Salcs tax rclatioto construction and construction materials in the City of Arlington must be reported on your sales tax return form and c cd City o Arlin n�L mature Print Name Date Released By ale CONDITIONS See redlined plans for additional requirements. Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0.00 Balance Due: S0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Print Form FIRE SPRINKLER PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington,WA 98223• Phone(360)403 3551 • FAX (360)403 3447 THIS APPLICATION MUST BE ACCOMPANIED BY FIVE(5) SETS OF COMPLETE AND SCALED PLANS, FIVE(5) SETS OF HYDRALIC CALCULATIONS,FIVE(5) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: a New Fire Sprinkler ®) Fire Sprinkler Add/Alt ® Underground Fire Line Project Address: 17716 48TH DR Parcel ID#: Project Valuation: 159.811 Number of Heads 202 Building Area(Sq Ft): 19,200 Owner: Abbatare, Inc. Phone Number: 360 474-1993 Address: 17617 49th Ave NE #B City: State: Zip Code:Arlington WA 98223 Contact Person:Hans von der Hofen Phone Number: 360 474-1993 Cell Phone: Fax: E-mail: Address: same as above City: State: Zip Code: Contractor: Commercial Fire Protection, Inc. Phone Number: 360 848-9093 EXT 122 Address: City: 17199 Bennett Rd Mount Vernon State: WA Zip Code:98273 Contractor's License Number:COMMEFP132MM Expiration:08-16-16 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- s ed prop will accordance with the laws, rules and regulation of the State of Washington. Ap li Sign t�Fe Date lc� Print Applicants Name ml6vv saa�a FOR STAFF USE ONLY �- Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 04/08 sb March 14, 2008 Sprinkler 41a MicrofastHP° QUICK RESPONSE PENDENT _ N1KJW*JSPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfase and MicrofastHP®Quick Response Pendent Sprinklers are small, thermosensitive,glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements.The special Polyester and Teflon®coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart.(Note: FM Global has no approval classification for Teflon®and Polyester coat- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV ` FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E,Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. FFICE 3. TECHNICAL DATA CON Specifications: Available since 1987. Viking Technical Data may be found on Minimum Operating Pressure: 7 psi(0.5 bar) The Viking Corporation's Web site at Maximum Working Pressure:Sprinklers 12282 and 12290 are rated for http://www.vikinggroupinc.com. use with water working pressures ranging from the minimum 7 psi TyV��Tr �e n (0.5 bar)up to 250 psi (17 bar)for high-pressure systems. High-pres- UAit�mi�f e T sure(HP)sprinklers can be identified by locating "250"stamped on BUILDING EPARTMEW the deflector.All other Part Nos.not mentioned above are rated to a maximum 176 psi(12 bar)wwp. APPROVED Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart MOP Nominal K-Factor: Refer to the Approval Chart WOC"ANMALnwoyalm Glass-bulb fluid temperature rated to-65°F (-55°C) MESS APPIROVED BYTH4 Overall Length: Refer to the Approval Chart BUILDING INSPECTOR Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-Cl9500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Received Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 AUG 12 2015 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 066666,Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 MICROFASTO AND MicrofastHP®QUICK RESPONSE PENDENT . N41KJM4 IN : SPRINKLERS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon®Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon®Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast®and MicrofastHP®Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome-Enloy®=F,White Polyester= M-/W, Black Polyester=M-/B, and Black Teflon®= N Temperature Suffix(°F/°C): 135*/57° =A, 155°/68* = B, 175*/79°= D, 200°/93° = E, and 286*/141* =G For example, sprinkler VK302 with a 1/2"thread, Brass finish and a 155°F/68°C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B(available since 2000). B.Wrench for coated and/or recessed sprinklers: Part No. 12144W/B**(available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A%"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS TESTS AND MAINTENANCE r�� e o or p$ged n,Testing and Maintenance requirements :ice Rdt e a ► '-A �;� � ,..ea.v 7. LS�;O {l,y� ThetViking Mjerofast11Land.4,4icrofastHF* uick Response Pendent Wrench Spr{{lhklersaarw-availlabte rough a n twork of domestic and Flats international distributors. See Thg Vikin Corporation web site for Protective JqN distributor ccroyThe Uiing Corporation. Sprinkler _ _ Cap 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule 4-contact Viking directly. 10896 =0 Figure 1: Standard Sprinkler Wrench 10896W/B March 14, 2008 Sprinkler 41 c MicrofastHP®QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100-F(38°C) Red Intermediate 175°F(79°C) 150-F(65°C) Yellow Intermediate 200°F(93-C) 150°F(65°C) Green High 286°F(141 °C) 225°F(107°C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon® Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41 d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon®coatings. 1 , 1 Sprinkler Wrench ! _ 12144W/B)K)K for installing coated and/or recessed pendent sprinklers N Carefully slide the f f with protective caps, F_ _____:__; wrench sideways around the protective cap, ensuring engage- `'""----`' vent with the sprinkler —A 1/2' ratchet is required wrench flats, (not available from Viking), Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d March 14, 2008 FAST",AND N EM MicrofastHP° QUICK M RESPONSE PENDENT I KJ W*JSPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart �Tempe alum KEY Microfase and MlcrofastHP®Quick Response Pendent Sprinklers A&I (N&pw ) Maximum 175 PSI(12 bar)WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41 e.) Part No.' NPT BSP U.S. metric' Inches mm cULus4 FM" I NYC- I VdS LPCB C E Standard Orifice 06662E J VK302 1 1/2" 15 mm 1 5.6 80.6 2-1/4" 58 1 AIX, B1Y I A3X,133Y AIX, B1Y A3 A3X,133Y C3X,E3Y13 C3X,E3Y15 Large Orifice 06666B VK352 3/4" 20 mm I 8.0 115.2 2-3/8" 60 AIX,B1Y A2X,132Y AIX, B1Y — A3X C313 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 1 -- -- — G3 — 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 1 AIX, B1Y — AIX, B1Y A3 — — Small Orifice' 067181310 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AIX,B1Y A2X AIX, B1Y — - 06720B1D VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 AIX,B1Y - AIX, B1Y — 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- — A3 G214 Maximum 250 PSI(17 bar)WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' i NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" VdS LPCB C E 0 12282 I VK317 1/2" 15 mm 56 80.6 2-1/4" 58 AIX,B1Y — AIX — — Maximum 250 PSI(17 bar)WWP Small Orifice' 1229010 ! VK342 1 1/2" 15 mm 1 2.8 1 40.3 1 2-3/16" 56 1 AIX,B1Y — AIX — — — — Approved Temperature Ratings Approved Escutcheons A-135°F(57-C), 155°F(68-C),175-F(79°C),200°F(93-C), Approved Finishes X - Standard surface-mounted escutcheon or and 286°F(141 °C) 1 - Brass, Chrome-Enloy°, White Poly- the Viking Microfast° Model F-1 Adjustable B-135-F(57-C),155°F(68°C),175°F(79'C),and 200°F(93°C) ester',', Black Pol ester'B, and Black Escutcheon12 C - 155 °F (68 -C), 175 -F (79 °C), 200 °F (93 °C), and 286 °F y (141 -C) TeflonO7 Y - Standard surface-mounted escutcheon or D - 135 -F (57 -C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2-Brass and Chrome-Enloyo the Viking Microfast® Model F-1 Adjustable (141 -C) 3-Brass,Chrome-Enloy°,White Polyesters, Escutcheon12 or recessed with the Viking E-155°F(68°C), 175°F(79°C),and 200°F(93°C) and Black Polyester' Micromati& Model E-1 or E-2 Recessed F-155°F(68°C), 175°F(79°C),and 286°F(141 °C) G-155°F(68°C) Escutcheon Footnotes 1 Base part number is shown. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S.and Canada. 5 FM Approved for use only in wet-pipe sprinkler systems(or preaclion systems qualifying as wet systems)for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. Accepted for use,City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 7 cULus Listed as corrosion resistant. a Other colors are available on request with the same Listings and Approvals as the standard colors. 'Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or intemally galvanized. 1°The sprinkler orifice is bushed. "Accepted for use,City of New York Department of Buildings.MEA Number 89-92-E.Vol. 16. 12The Viking Microfast= Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 CE Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 0 MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. March 14, 2008 Sprinkler 41e MICROFASTOAND MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 41d) cULus Listing Reauirements: MicrofaW and MicrofastHP®Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies(exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aor?roval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets(including 2-8N)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 mm) minimum 2-1/8' 2-1/2' (63.5 mm) maximum (54 mm) 1/2' C15 —� NPT t 16® 1-3/4' f 2-1/4" (44.5 mm) 2° 1-1/2' (38.1 mm) 1-5/8' (58 mm) (50.8 mm) Minimum (4�) � Maxlimum 1 � Installed with a Pendent Sprinkler standard 1/8' surface- 06662B (VK302) mounted escutcheon. Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 41 f March 14, 2008 MICROFASTOAND MicrofastHP®QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 2-1/8' Ceiling Opening Size; 2-1/8 �J (54 mm) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum t�1►91a01�® ��` �y 1-1/8' (28.6 mm) 1-3/4' J Minimum 2„ 1-1/8' (28.6 mm) (44,5 mm) Minimum Max Maximum ( mm) Maximum Installed with a Micromatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 0666613,Added Dry System note in approval chart for Small Orifice.) February 12, 2010 Sprinkler 11 q MICROMATIC°AND MicromaticHP°STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Micromaticm and MicromaticHP" Standard Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray � sprinklers available in several different finishes, temperature ratings, and K- 'f ` Factors to meet design requirements. The special Polyester and Teflon® coat- ings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart.(Note: FM Global has no approval classification for Teflon®and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 11 r. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA 89-92-E, Volumes 3 and 12 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060055, G4980001, G4980003, G4980004, and G4980008 LPC Approved: Ref. No. 096e/06 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, 0786- CPD-40142, 0786-CPD-40177, and 0786-CPD-40182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Charts on pages 11t and 11 u and Design Criteria on page 11v for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: 7 psi (0.5 bar)' Maximum Working Pressure:Sprinklers VK021 and VK124 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi (17 bar)for high-pressure systems. High-pres- http://www.vikinggroupinc.com. sure(HP)sprinklers can be identified by locating "250"stamped on The Web site may include a more recent the deflector.All other Part Nos. not mentioned above are rated to a edition of this Technical Data Page. maximum 175 psi(12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts "Wl_us Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 09993, 10138, 10227, and 10233. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-Cl9500 for Sprinklers 10138 and 10193. Copper UNS-Cl9500 for Sprinklers 10141, 10169, 10174, 10220, 10233, and 12106. Brass UNS-C26000 for all other Sprinklers. Form No. F_080106 Received Replaces page 11q-v, dated January 22, 2010. (Added alternate frame mate- rial for Sprinklers 09993, 10138, 10227,and 10233.Also added VdS Approval AUG 12 2015 to Sprinkler 10169 and removed VdS Approval from Sprinkler 10220.) ?jLb -1(Q?- Sprinkler 11 r February 12, 2010 MICROMATIC°AND MicromaticHP° STANDARD N1KJNC* UPRIGHT AND EMECORESPONSE NVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09993 and 09995: Brass UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment(for Sprinkler VK001): Brass UNS-C36000 Ejector Spring (for Sprinkler 10169): 17-7 Stainless Steel ForTefton®Coated S rinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon®Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Micromati&and MicromaticHP®Standard Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome-Enloy°= F, White Polyester= M-/W, Black Polyester= M-/B, and Black Teflon®= N, Wax Coated =C, Wax Over Polyester=V-/W Temperature Suffix(°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, 212°/100°= M, 286°/141° = G, 360°/182° = H, 500°/260°= L, OPEN =Z(Teflon"only). For example, sprinkler VK100 with a 1/2"thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 10138AB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for wax-coated sprinklers: Part No. 13577W/B**(available since 2006) **A'/="ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromati& and MicromaticHP° Standard Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. February 12, 2010 Sprinkler 11 s MICROMATIC°AND MicromaticHP°STANDARD WAJ RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9601 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175°F(79°C) 150°F(65°C) Yellow Intermediate 200°F(93°C) 150°F(65°C) Green Intermediate 212 °F(100°C) 150°F(65°C) Green High 286°F(141 °C) 225°F(107°C) Blue Extra High 360°F(182°C) 300°F(149°C) Mauve Ultra High' 500°F(260°C) 465°F(240°C) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon®in all temperature ratings. Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax" 286 °F (141 °C) Dk. Brown Wax" Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers.or similar enclosures with normal operating temperatures above 300`F(149`C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300'F (149 C), response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 111. These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and Teflon coatings. For Teflon coated open sprinklers only,the"vatervvay is coated 5 Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. e Wax melting point is 170`F(76'C)for 212`F(100'C)and 286�F(141 'C)temperature rated sprinklers. Protective Sprinkler Wrench Cap Plat qt 10896 m Figure 1: Standard Sprinkler Wrench 10896W/B Sprinkler 11t February 12, 2010 MICROMATIC°AND MicromaticHP°STANDARD RESPONSE UPRIGHT AND N I KJ CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-6464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 TRPpMat„_ KEY I Micromatic'and MicromaticHP�Standard Response Upright Sprinklers I ' rKo Maximum 175 PSI (12 bar)WWP Atx� Escutcheon pf appbcatwei Base Thread Size ' Nominal Overall Listings and Approvals' Part SIN K-Factor Length (Refer also to Design Criteria on page 11v.) Number' _ffP_Tj BSP U.S.I metricz Flnches I mm cULus' FM NYCG VdS LPCB 70 O" U rl ht-Standard Orifice 10138 VK100 1/2' 15 mm 5.6 80.6 2-3/16 56 81 D5 E7 F4 A2. C6, E7, F2 H5 B1 D5, E7 10233 VK145 1/2" 15 mm 5.6 80.6 2-3116 56 A2 D3, E7, F2 — B2 B2, D5B2 G2 10174 VK145 -- 15 mm 5.6 1 80.6 2-3116 56 A2. D3 F2 B2 D5 — — 10193 VK100 -- 115mm 5.61 80.6 2-3/16 56 B1, D5 E7 F4 A2 D3 F2 H5 B1 E15 E7 - UDright-Larcie Orifice 10220 IVK200 1/2"115 mml 8.0 1 115.2 1 2-3/8 1 60 1 61 D5. E7 F4 I B2, D6 F2 B1 D5 I G4 I G4 10141 VK200 314"120 mml 8.0 1 115.2 12-5/161 59 1 B1 D5 E7 F4 I B2 D6 F2 I B1 D5 E71 I G4 I G4 10169 VK200 3/4"1 -- 18.01 115.2 12-5/161 59 1 1 — I — I B2 U ri ht-Small Orifice$ 102189 VK001 1/2" 15 mm 2.8 40.3 2-3/16 56 B1, D5 E7 D4, D6 — — — — 102191 VK002 1/2" 15 mm 4.2 60.0 2-3/16 56 B1 D5 E7 - — 101919 VK002 -- 15 mm 4.2 60.0 2-3/16 56 B1 D5 E7 — 101929 VK001 -- 15 mm 2.8 40.3 2-3/16 56 61 D5, E7 D4. D6 — — — — 10176 VK002 -- 10 mm 4.2 60.0 2-3/16 56 — — — B2 B2, D5 G2 G2 Maximum 250 PSI(17 bar)WWP Upright-Standard Orifice 09993 VK124 1/2"115 mm 1 5.61 80.6 1 2-1/4 1 58 1 B1 F5 Upricalht-Small Orifice$ 099959 1 VK021 1/2"115 mm 1 2.8 1 40.3 1 2-114 1 58 1 B1 Approved Temperature Ratings A-135°F(57°C),155°F(68°C), 175°F(79°C),200°F(93°C),212°F Approved Finishes (100°C),286°F(141 °C),and 360°F(182°C) 1 - Brass, Chrome-Enloy°, White Polyesters, Black Polyester,, and Black B-135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C),286°F Teflon"' (141 °C),and 360°F(182°C) 2-Brass,Chrome-Enloy=,White Polyester,and Black Polyester C- 135°F (57°C), 155 °F(68 °C), 175°F(79 °C), 200°F (93°C), and 3-White Polyester and Wax-Coated Brass(corrosion resistant) 212°F(100°C) 4-Brass and Chrome-Enloy" D-135°F(57°C), 155°F(68°C), 175°F(79°C),and 200°F(93°C) 5-Wax-Coated Brass and Wax over Polyester, E-286°F(141 °C) F-500°F(260°C)7 6-Wax-Coated Brass(corrosion resistant) G-155°F(68°C), 175°F(79°C),200 °F(93°C),286°F(141 °C), and 7 - 200 °F (93 °C) High-Temperature Wax Coating (corrosion resistant); 360°F(182°C) maximum ambient temperature allowed at ceiling=150°F(65°C) H-155°F(68°C) Footnotes Base part number is shown. For complete part number,refer to Viking's current price schedule. z Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. ,cULus Listed as corrosion resistant. 6 Accepted for use,City of New York Department of Buildings, MEA Number 89-92-E,Vol. 12. 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F(149°C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 9 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 9 The sprinkler orifice is bushed. 'off£Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40137,0786-CPD-40177,0832-CPD-2001,and 0832-CPD-2003. 11 0 MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. February 12, 2010 Sprinkler 11 u NIMM4 IMM MICROMATIC°AND MicromaticHP° STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 Temperature KE Micromatic®and MicromaticHP9Standard Response Conventional Sprinklers A1Xt EtsWlcfironftlapptca�le) _Maximum 175 PSI(12 bar)WWP Base Nominal Listings and Approvals3 Part SIN Thread Size K-Factor Overall Length t e page I Refer also to Design Criteria on a e 11v. Number' NPT BSP U.S. I metric1 I Inches mm cULus° I FM I NYC' I VdS I LPCB I CE 1 d Conventional-Standard Orifice 10227 VK118 1/2" 115 mm 5.6 80.6 1 2-3/16 1 56 1 Al B4 C5 JAI. 64, C51 A2 I A2 64 1 A21 D210 101726 1 VK118 — 115 mm 1 5.6 1 80.6 1 2-3/16 1 56 1 Al B4 C5 — -- I A2 64 1 — — Conventional-Lar a Orifice 10228 1 VK120 3/4" 120 mm 1 8.0 1 115.2 1 2-5/16 59 Al, B4 C5 — Al 84 C5 A2 134 1 D3$ I D210 101681i I VK120 I — 120 mm 1 8.0 1 115.2 2-5/16 59 Al. B4 C5 — A2 B4 I D36 I D310 12106 1 VK120 1 3/4" 120 mm 1 8.0 1 115.2 1 2-5/16 59 — — A2 I — I A29 Approved Temperature Ratings Approved Finishes A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C),286°F 1 - Brass, Chrome-Enloy', White Polyester, Black Polyester', and Black (141 °C), and 360°F(182°C) TeflonCS B-135°F(57°C), 155°F(68°C), 175°F(79°C),and 200°F(93°C) 2-Brass,Chrome-Enloy°',White Polyester,and Black Polyester C-286°F(141 °C) 3-Brass and Chrome-Enloy" D- 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), 4-Wax-Coated Brass and Wax over Polyesters and 360°F(182°C) 5-200°F(93°C) High-Temperature Wax Coating (corrosion resistant); maxi- mum ambient temperature allowed at ceiling= 150°F(65°C) Footnotes 1 Base part number is shown.For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 cULus Listed as corrosion resistant. 8 Sprinklers 10168 and 10172 are available on special order. 7 Accepted for use,City of New York Department of Buildings, MEA Number 89-92-E,Vol.3. e(ECertified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 0(E Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40142 and 0786-CPD-40182. 10 O MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Sprinkler 11v February 12, 2010 MICROMATIC°AND N4 I Ki Nc* MicromaticHP°STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Charts on pages 1 tt-u) cULus Listina Reauirements: Micromati&and MicromaticHP' Standard Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Charts for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers,or old style(conventional)sprinklers. • Designed for use in Light,Ordinary,and Extra Hazard occupancies. (Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied,with hydraulically calculated wet systems only.Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized.) • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers,refer to the installation guidelines for old style(conventional)sprinklers. FM Approval Requirements: Micromati&and MicromaticHP"Standard Response Upright Sprinklers are FM Approved as indicated in Approval Chart 1 for installation in accordance with the latest applicable FM Loss Prevention Data Sheets(includig 2-8N)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Sprinkler Wrench 13577W/B#)K Must be used for installing wax coated sprinklers f Step 1: Carefully slide l the wrench sideways around the deflector, ensuring engagement with the sprinkler wrench flats. Wax Coated 1 \'alltll�� ®mil _ J Upright Sprinkler 1 1 I 1 )KA 112' ratchet is required Step 2i Carefully press the wrench (not available from Viking). downward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Wax Coated Sprinklers Replaces page 11q-v, dated January 22,2010. (Added alternate frame mate- rial for Sprinklers 09993, 10138, 10227,and 10233.Also added VdS Approval to Sprinkler 10169 and removed VdS Approval from Sprinkler 10220.) ZURNo - o Double Check Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of ` polluted water into the potable water supply.Model 350ASTDA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and a unauthorized water use. i' Standards Compliance(Horizontal&Vertical) •ASSEO Listed 1048 •AWWA Compliant C510(with gates only)and C550 Options(Suffixes can be combined) • ULO Classified ❑ - with flanged end OS&Y gate valves(standard) • C-ULO Classified ❑ LM - less water meter • FMO Approved ❑ - with remote reading meter • CSAO Certified ❑ - with gallon meter(standard) •Approved by the Foundation for Cross Connection ❑ CFM - with cu ft meter Control and Hydraulic Research at the University of South- ❑ CMM - with cu meter meter ern California ❑ G - with grooved end OS&Y gate valves • NSFO Listed-Standard 61,Annex G* ❑ FG - with flanged inlet gate connection and grooved *(0.25% MAX.WEIGHTED AVERAGE LEAD CONTENT) outlet gate connection Materials ❑ PI - with Post Indicator Gate Valves Main valve body 304L Stainless steel ❑ BG- with grooved end butterfly valves with integral Access covers 304L Stainless steel supervisory switches(2-1/2" -6") Internals Stainless steel,300 Series ❑ BF- with flanged end butterfly valves with integral NORYLTM, NSF Listed supervisory switches(2-1/2" -6") Fasteners&springs Stainless Steel,300 Series ❑BGVIC- with grooved end butterfly valves with integral Elastomers EPDM (FDA approved) supervisory switches(8" -10") Buna Nitrile(FDA approved) Polymers NORYLTM, NSF Listed Accessories Features ❑ Repair kit(rubber only) Sizes: 2 1/2", 3", 4119 6"1 8% 10" ❑ Thermal expansion tank(Model XT) Maximum working water pressure 175 PSI ❑ OS&Y Gate valve tamper switch(OSY-40) Maximum working water temperature 140*F Hydrostatic test pressure 350 PSI MODEL End connections (Grooved for steel pipe) AWWA C606 350ASTDA Flan ANSI616.1 With (Flanged)) OS&Y option Class 125 E Dimensions&Weights(do not include pkg.) WEIGHT MODEL ,/ 44 GATES(GXF) 350ASTDA WITH OS&Y WITH OS&Y WITH WITH `( F SIZE GATES BUTTERFLY BUTTERFLY C— (GXG) VALVES(GXG) VALVES(FXG) I a o A I d—� in. mm lbs. kg lbs. kg lbs. kg lbs. kg 2 1/2 65 126 57 116 53 93 42 103 1 47 MODEL 3 80 143 65 131 60 97 44 110 50 350ASTDA = 4 100 218 99 198 90 101 46 123 56 BF with option o 0 ® 6 150 352 160 322 147 164 74 194 88 ° 8 200 667 303 613 278 314 142 n/a n/a c 10 250 885 401 827 375 419 190 n/a n/a MODEL DIMENSION(approximate) 350ASTDA i A WITH B LESS E E E WITH SIZE A BUTTERFLY GATE C D OS&Y OS&Y BUTTERFLY F VALVES VALVES OPEN CLOSED VALVES in I mm in mm in I mm in mm in mm in I mm in mm in I mm in I mm in mm 21/21 65 31 7/8 810 28 3/4 730 n/a n/a 12 305 7 1/4 184 17 3/4 451 15 3/8 391 8 1/4 210 5 127 3 80 32 7/8 835 29 3/8 746 n/a n/a 12 305 7 1/4 184 20 1/4 514 17 432 8 1/4 210 5 127 4 100 1 34 7/8 886 1 30 1/4 768 n/a n/a 1 12 305 8 203 1 22 1/2 572 18 1/4 464 9 229 5 127 6 150 431/2 1105 1 361/2 927 n/a n/a 101/2 267 10 254 301/2 775 241/4 616 101/4 260 6 152 8 200 52 3/4 1340 45 3/4 1162 n/a n/a 15 1/8 384 11 279 37 940 281/2 724 18 1/2 470 8 3/8 213 10 1250 55 3/4 1416 1 49 3/4 1264 n/a n/a 15 1/8 384 12 305 45 5/8 1159 34 3/4 883 18 1/2 470 8 3/8 213 Zurn Industries,LLC Wilkins Rev.F 1747 Commerce Way,Paso Robles,CA U.S.A.93446•Ph.855-663-9876,Fax 805-238-5766 Received Date:2114 In Canada : Zurn Industries Limited Document No.BF-350ASTDA 3544 Nashua Drive,Mississauga,Ontario L4V 1 L2•Ph.905-405-8272,Fax 905-405-1292 Patent No.5,913,331 AUG 12 2015 Product No.Model 350ASTDA Page 1 of 2 ,E)Lb1(Q?- Flow Characteristics O Rated Flow(esiablishcd by approval agencies) MODEL 350ASTDA 2 1/2",3"&4"(STANDARD&METRIC) FLOW RATES(1/s) 0.0 12.6 25.2 37.9 50.5 O 15 104 m d3'BMnm n- --� 4-(1100mm) N 10 69 Vi 0 0 W w tr w 5 35 to U) W w W 0_ IL a. 0 0 0 200 400 600 800 FLOW RATES(GPM) MODEL 350ASTDA 6" 8"&10"(STANDARD AND METRIC) FLOW RATES(1/s) 0.0 63.1 126.2 189.3 252.4 20 _ 138 o — Vl _ m W 15 — - 10'(250mm) 1049 (r 150mm 8`(200mm) _ U) 1 10 69 W ___ --- - - -- — - w K of U) 5 35 U) — - - -. CO 0: W IL 0 0 a 0 1000 2000 3000 4000 FLOW RATE(GPM) Typical Installation CaDacity thru Schedule 40 PiDe(GPM) Local codes shall govern installation requirements. Unless PiDe size 5 ft/sec 7.5 ft/sec 1Oft/sec 15 ft/sec otherwise specified,the assembly shall be mounted at a 2 1/2" 75 112 149 224 minimum of 12" (305mm)and a maximum of 30"(762mm) 3" 115 173 230 346 above adequate drains with sufficient side clearance for test- 4" 198 298 397 595 ing and maintenance.The installation shall be made so that 6" 450 675 900 1351 no part of the unit can be submerged. 8" 780 1 1169 11559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 PROTECTIVE ?� ENCLOSURE O LL LL 0 Z 0 F W a: 12"MIN 30"MAX r t. DIRECTION OF FLOW �. ZURN WILKINS MODEL350ASTDABG ZURN WILKINS MODEL 350ASTDA INDOOR VERTICAL INSTALLATION OUTDOOR HORIZONTAL INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be ASSEO Listed 1048,and supplied with full port gate valves. The main body and access cover shall be 304L Stainless Steel,the seat ring and check valve shall be NoryITM(NSF Listed),the stem shall be stainless steel(ASTM A 276)and the seat disc elastomers shall be EPDM.The first and second check valves shall be accessible for maintenance without removing the device from the line.The Double Check Detector Backflow Prevention As- sembly shall be a ZURN WILKINS Model 350ASTDA. Zurn Industries,LLC ; Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446•Ph.855-663-9876,Fax 805-238-5766 In Canada j Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1L2-Ph.905-405-8272,Fax 905-405-1292 Page 2 of 2 C VIMERCIAL FIRE PR�-TECTION, INC. 17199 Bennett Road • Mt Vernon, Washington 98273 Phone (360) 848-9093 • Fax (360) 848-1072 License# COMMEFP132MM HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME ABBATARE HANGAR 10 JOB NO. 2015022 DATE 8/3/15 ADDRESS 17716 48TH DRIVE BY MIKE HINTON ARLINGTON, WA 98223 SYSTEM DESIGNATION: 1 HAZARD DESCRIPTION: AIRCRAFT HANGAR HAZARD CLASS PER NFPA 409 : GROUP II AIRCRAFT HANGAR SPECIFIC RULING: RULING MADE BY: OF DENSITY: .17 GPM OVER THE MOST HYDRAULICALLY REMOTE 5000 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 500 GPM NODE 0 IN-RACK SPRINKLER DEMAND N/A GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 202 "C"FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 130 SQUARE FEET SPRINKLER MANUFACTURER: VIKING MODEL: SR TEMPERATURE: 360 ° F K-FACTOR: 5.6 SIN#: VK100 WATER SUPPLY: ELEVATION OF TEST: 0 STATIC 94 PSI DATE OF TEST: N/A RESIDUAL 20 PSI DATA PROVIDED BY: CITY OF ARLINGTON FLOW 4000 GPM LOCATION OF TEST: SITE WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Mike Hinton 7358-0100-C Level 6�Ires j SUMMARY Commercial Fire Prolecton,Ina COMM FP132M 1433.44 GPM REQUIRED AT 69.46 PSI AT CONNECTION TO 8"WATERMAIN =1$=°i--------------- (INCLUDING 500 GPM FOR TOTAL HOSE STREAMS) CERTIFICATE OF COMPETENCY STAMP I' � 1 N V O)�(D �Lo r L Iq M Nr 0 L T a) CD co ao U) ca 3 N E o2a � clin. aQ O 0 m rn NNa) a) M M �N N� N >1>vT w(n(n (n '0rNN OM 10 N00 0 0 M O O (n CNN 2 Z E f6 L >C r O r O r N .O O U C U L O O r T O<IT 2 N Z E O M J p> LL O ^L LL L O N O a N E O U 0 0 co r 0 0)N'I .. O :3 O () N (/1 N U) o U)n LL a f° co ILI T 0 c: o U Ca i� a) a) o Q ai =3 (DrNN (A 3:UUU CD C) M N Or O O O O O O O O O O W W f,- CO Lo T Cl) N cu U r a w (n (n w -A � G2§ B S2k q 21 $a& \I ac co g0000 8r.-§ 04 Ko8 RLOS \ = 2#§ / \ co Cl)R = ± 2 L �C142 E k I 2042 § \ w-2 m a) CD / 152 0 » ��Q § Ike / o co a d e = ° — c \ o�� § ca ® — cu u > (- ��� \ $ U I © 2 %ƒ DE 2 ® #om aU \ $ § 2 $/ / \ 22 E ® CL noo $ £ CO" -a � � / a) E cc [ � E �o� 6-� / 3 # $ \ § E� 2 ® = ƒ � / a 22 « -% 2 J moo# 2 00 \— Ef 22 = 2 : 'CL h-- — m� won / I / 0 7 / : / EE cu ec25 .> 2 � 0c = 2 e /2F- 2E % L a) 2 � -0k � cu '$ 0 2 % 0 k E E k � » o = co = �2 = © 2 ® � = n2U- = m2@2 m mom Etc % ; £ QQ2 » 2 n 252E — / 2 = § E�� 2 =k / \� / Q2 z}$ E = f � = :_ £ X (D A -i� f - k § ma LL 3 cm� \ b § / K 0 4— \ \ L « Luce = o -iLa 2L » wc � 1 Pressure / Flow Summary - 5iHNuI�rcU Page 3 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 0 0.0 69.46 na 500.0 1 2.0 64.01 na 2 5.0 56.89 na 3 17.5 49.44 na 11 17.5 40.15 na 12 17.5 38.91 na 13 17.5 37.99 na 14 17.5 37.35 na 15 17.5 36.92 na 16 17.5 36.68 na 17 17.5 36.56 na 21 17.5 23.5 na 22 17.5 23.75 na 23 17.5 23.85 na 24 17.5 23.87 na 25 17.5 23.87 na 26 17.5 23.83 na 27 17.5 23.69 na 31 17.5 20.81 na 32 17.5 20.5 na 33 17.5 20.3 na 34 17.5 20.23 na 35 17.5 20.23 na 36 17.5 20.25 na 37 17.5 20.35 na 41 17.5 13.53 na 42 17.5 13.51 na 43 17.5 13.45 na 44 17.5 13.41 na 45 17.5 13.39 na 46 17.5 13.38 na 47 17.5 13.38 na 18 17.5 36.52 na 101 17.5 5.6 15.26 na 21.88 0.17 120 7.0 102 17.5 5.6 14.32 na 21.19 0.17 120 7.0 103 17.5 5.6 13.7 na 20.73 0.17 120 7.0 104 17.5 5.6 13.33 na 20.44 0.17 120 7.0 105 17.5 5.6 13.14 na 20.3 0.17 100 7.0 106 17.5 5.6 13.09 na 20.26 0.17 100 7.0 107 17.5 5.6 13.09 na 20.26 0.17 100 7.0 108 17.5 5.6 13.11 na 20.28 0.17 100 7.0 109 17.5 5.6 15.21 na 21.84 0.17 120 7.0 110 17.5 5.6 14.28 na 21.16 0.17 120 7.0 111 17.5 5.6 13.66 na 20.7 0.17 120 7.0 112 17.5 5.6 13.29 na 20.41 0.17 120 7.0 113 17.5 5.6 13.1 na 20.27 0.17 100 7.0 114 17.5 5.6 13.05 na 20.23 0.17 100 7.0 115 17.5 5.6 13.05 na 20.23 0.17 100 7.0 116 17.5 5.6 13.07 na 20.25 0.17 100 7.0 117 17.5 5.6 15.2 na 21.83 0.17 120 7.0 118 17.5 5.6 14.26 na 21.15 0.17 120 7.0 119 17.5 5.6 13.64 na 20.68 0.17 120 7.0 120 17.5 5.6 13.27 na 20.4 0.17 120 7.0 121 17.5 5.6 13.08 na 20.26 0.17 100 7.0 122 17.5 5.6 13.03 na 20.22 0.17 100 7.0 123 17.5 5.6 13.03 na 20.21 0.17 100 7.0 124 17.5 5.6 13.05 na 20.23 0.17 100 7.0 125 17.5 5.6 15.34 na 21.93 0.17 120 7.0 126 17.5 5.6 14.44 na 21.28 0.17 120 7.0 127 17.5 5.6 13.84 na 20.83 0.17 120 7.0 128 17.5 5.6 13.49 na 20.57 0.17 120 7.0 129 17.5 5.6 13.32 na 20.44 0.17 120 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 Flow Summary- Standard Page 4 Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req 130 17.5 5.6 13.27 na 20.4 0.17 120 7.0 131 17.5 5.6 13.27 na 20.4 0.17 120 7.0 132 17.5 5.6 15.39 na 21.97 0.17 120 7.0 133 17.5 5.6 14.47 na 21.3 0.17 120 7.0 134 17.5 5.6 13.86 na 20.85 0.17 120 7.0 135 17.5 5.6 13.5 na 20.58 0.17 120 7.0 136 17.5 5.6 13.33 na 20.45 0.17 120 7.0 137 17.5 5.6 13.28 na 20.41 0.17 120 7.0 138 17.5 5.6 13.28 na 20.4 0.17 120 7.0 38 17.5 20.61 na 139 17.5 5.6 15.5 na 22.05 0.17 120 7.0 140 17.5 5.6 14.55 na 21.36 0.17 120 7.0 141 17.5 5.6 13.92 na 20.89 0.17 120 7.0 142 17.5 5.6 13.54 na 20.61 0.17 120 7.0 143 17.5 5.6 13.36 na 20.47 0.17 120 7.0 144 17.5 5.6 13.29 na 20.42 0.17 120 7.0 145 17.5 5.6 13.29 na 20.42 0.17 120 7.0 28 17.5 23.41 na The maximum velocity is 20.53 and it occurs in the pipe between nodes 1 and 2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 .i Final Calculations - Hazen-Williams Page 5 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln Total Pf Pn 0 -933.44 6.16 1 T 43.037 125.000 69.463 Qa = 500 to 140.0 1 G 4.304 87.509 -0.866 1 -933.44 -0.0216 2E 40.168 212.509 -4.587 Vel = 10.05 1 0.0 4.31 0.0 5.000 64.010 to 120.0 0.0 0.0 -6.299 * Fixed loss = -5 2 -933.44 -0.1636 0.0 5.000 -0.818 Vel = 20.53 2 0.0 4.31 0.0 12.500 56.893 to 120.0 0.0 0.0 -5.414 3 -933.44 -0.1634 0.0 12.500 -2.043 Vel = 20.53 3 0.0 4.31 3E 41.811 15.000 49.436 to 120.0 0.0 41.811 0.0 11 -933.44 -0.1635 0.0 56.811 -9.286 Vel = 20.53 11 128.69 4.31 0.0 10.000 40.150 to 120.0 0.0 0.0 0.0 12 -804.75 -0.1243 0.0 10.000 -1.243 Vel = 17.70 12 122.34 4.31 0.0 10.000 38.907 to 120.0 0.0 0.0 0.0 13 -682.41 -0.0915 0.0 10.000 -0.915 Vel = 15.01 13 117.82 4.31 0.0 10.000 37.992 to 120.0 0.0 0.0 0.0 14 -564.59 -0.0645 0.0 10.000 -0.645 Vel = 12.42 14 114.79 4.31 0.0 10.000 37.347 to 120.0 0.0 0.0 0.0 15 -449.8 -0.0424 0.0 10.000 -0.424 Vel = 9.89 15 112.82 4.31 0.0 10.000 36.923 to 120.0 0.0 0.0 0.0 16 -336.98 -0.0248 0.0 10.000 -0.248 Vel = 7.41 16 111.88 4.31 0.0 10.000 36.675 to 120.0 0.0 0.0 0.0 17 -225.1 -0.0117 0.0 10.000 -0.117 Vel = 4.95 17 111.97 4.31 0.0 10.000 36.558 to 120.0 0.0 0.0 0.0 18 -113.13 -0.0033 0.0 10.000 -0.033 Vel = 2.49 0.0 -113.13 _ 36.525 K Factor= -18.72 21 333.13 4.31 0.0 10.000 23.502 to 120.0 0.0 0.0 0.0 22 333.13 0.0243 0.0 10.000 0.243 Vel = 7.33 22 -122.34 4.31 0.0 10.000 23.745 to 120.0 0.0 0.0 0.0 23 210.79 0.0104 0.0 10.000 0.104 Vel = 4.64 23 -117.83 4.31 0.0 10.000 23.849 to 120.0 0.0 0.0 0.0 24 92.96 0.0023 0.0 10.000 0.023 Vel = 2.04 24 -114.78 4.31 0.0 10.000 23.872 to 120.0 0.0 0.0 0.0 25 -21.82 -0.0001 0.0 10.000 -0.001 Vel = 0.48 25 -112.83 4.31 0.0 10.000 23.871 to 120.0 0.0 0.0 0.0 26 -134.65 -0.0046 0.0 10.000 -0.046 Vel = 2.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-wimams Page 6 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "**"''" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 26 -111.87 4.31 0.0 10.000 23.825 to 120.0 0.0 0.0 0.0 27 -246.52 -0.0139 0.0 10.000 -0.139 Vel = 5.42 27 -111.98 4.31 0.0 10.000 23.686 to 120.0 0.0 0.0 0.0 28 -358.5 -0.0278 0.0 10.000 -0.278 Vel = 7.88 0.0 -358.50 23.408 K Factor=-74.10 31 -379.53 4.31 0.0 10.000 20.810 to 120.0 0.0 0.0 0.0 32 -379.53 -0.0309 0.0 10.000 -0.309 Vel = 8.35 32 80.48 4.31 0.0 10.000 20.501 to 120.0 0.0 0.0 0.0 33 -299.05 -0.0199 0.0 10.000 -0.199 Vel = 6.58 33 128.86 4.31 0.0 10.000 20.302 to 120.0 0.0 0.0 0.0 34 -170.19 -0.0070 0.0 10.000 -0.070 Vel = 3.74 34 128.58 4.31 0.0 10.000 20.232 to 120.0 0.0 0.0 0.0 35 -41.61 -0.0006 0.0 10.000_ -0.006 Vel = 0.92 35 128.67 4.31 0.0 10.000 20.226 to 120.0 0.0 0.0 0.0 36 87.06 0.0021 0.0 10.000 0.021 Vel = 1.91 36 126.96 4.31 0.0 10.000 20.247 to 120.0 0.0 0.0 0.0 37 214.02 0.0107 0.0 10.000 0.107 Vel = 4.71 37 127.82 4.31 0.0 10.000 20.354 to 120.0 0.0 0.0 0.0 38 341.84 0.0255 0.0 10.000 0.255 Vel = 7.52 0.0 341.84 20.609 K Factor= 75.30 41 -82.28 4.31 0.0 10.000 13.532 to 120.0 0.0 0.0 0.0 42 -82.28 -0.0018 0.0 10.000 -0.018 Vel = 1.81 42 -80.48 4.31 0.0 10.000 13.514 to 120.0 0.0 0.0 0.0 43 -162.76 -0.0065 0.0 10.000 -0.065 Vel = 3.58 43 36.49 4.31 0.0 10.000 13.449 to 120.0 0.0 0.0 0.0 44 -126.27 -0.0040 0.0 10.000 -0.040 Vel = 2.78 44 36.49 4.31 0.0 10.000 13.409 to 120.0 0.0 0.0 0.0 45 -89.78 -0.0022 0.0 10.000 -0.022 Vel = 1.97 45 36.31 4.31 0.0 10.000 13.387 to 120.0 0.0 0.0 0.0 46 -53.47 -0.0008 0.0 10.000 -0.008 Vel =- 1.18 46 18.91 4.31 0.0 10.000 13.379 to 120.0 0.0 0.0 0.0 47 -34.56 -0.0003 0.0 10.000 -0.003 Vel = 0.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 7 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 47 18.14 4.31 0.0 10.000 13.376 to 120.0 0.0 0.0 7.579 48 -16.42 -0.0001 0.0 10.000 -0.001 Vel = 0.36 0.0 -16.42 20.954 K Factor= -3.59 11 -128.68 2.203 4T 54.555 97.000 40.150 to 120.0 0.0 54.555 0.0 21 -128.68 -0.1098 0.0 151.555 -16.648 Vel = 10.83 0.0 -128.68 23.502 K Factor=-26.54 12 -122.34 2.203 4T 54.555 97.000 38.907 to 120.0 0.0 54.555 0.0 22 -122.34 -0.1000 0.0 151.555 -15.162 Vel = 10.30 0.0 -122.34 23.745 K Factor=-25.11 13 -117.82 2.203 4T 54.555 97.000 37.992 to 120.0 0.0 54.555 0.0 23 -117.82 -0.0933 0.0 151.555 -14.143 Vel = 9.92 0.0 -117.82 23.849 K Factor= -24.13 14 -114.78 2.203 4T 54.555 97.000 37.347 to 120.0 0.0 54.555 0.0 24 -114.78 -0.0889 0.0 151.555 -13.475 Vel= 9.66 0.0 -114.78 23.872 K Factor= -23.49 15 -112.83 2.203 4T 54.555 97.000 36.923 to 120.0 0.0 54.555 0.0 25 -112.83 -0.0861 0.0 151.555 -13.052 Vel= 9.50 0.0 -112.83 23.871 K Factor= -23.09 16 -111.88 2.203 4T 54.555 97.000 36.675 to 120.0 0.0 54.555 0.0 26 -111.88 -0.0848 0.0 151.555 -12.850 Vel= 9.42 0.0 -111.88 23.825 K Factor= -22.92 17 -111.98 2.203 4T 54.555 97.000 36.558 to 120.0 0.0 54.555 0.0 27 -111.98 -0.0849 0.0 151.555 -12.872 Vel = 9.43 0.0 -111.98 23.686 K Factor= -23.01 18 -113.13 2.203 4T 54.555 97.000 36.525 to 120.0 0.0 54.555 0.0 28 -113.13 -0.0865 0.0 151.555 -13.117 Vel= 9.52 0.0 -113.13 23.408 K Factor=-23.38 31 -82.28 2.203 4T 54.555 97.000 20.810 to 120.0 0.0 54.555 0.0 41 -82.28 -0.0480 0.0 151.555 -7.278 Vel = 6.93 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 8 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -82.28 13.532 K Factor=-22.37 32 -80.48 2.203 4T 54.555 97.000 20.501 to 120.0 0.0 54.555 0.0 42 -80.48 -0.0461 0.0 151.555 -6.987 Vel = 6.77 0.0 -80.48 13.514 K Factor=-21.89 33 -128.86 2.203 2T 27.277 18.500 20.302 to 120.0 0.0 27.277 0.0 101 -128.86 -0.1101 0.0 45.777 -5.041 Vel = 10.85 101 21.88 2.203 0.0 12.000 15.261 K Factor= 5.60 to 120.0 0.0 0.0 0.0 102 -106.98 -0.0781 0.0 12.000 -0.937 Vel = 9.00 102 21.19 2.203 0.0 12.000 14.324 K Factor= 5.60 to 120.0 0.0 0.0 0.0 103 -85.79 -0.0518 0.0 12.000 -0.622 Vel = 7.22 103 20.73 2.203 0.0 12.000 13.702 K Factor= 5.60 to 120.0 0.0 0.0 0.0 104 -65.06 -0.0312 0.0 12.000 -0.374 Vel = 5.48 104 20.45 2.203 0.0 12.000 13.328 K Factor= 5.60 to 120.0 0.0 0.0 0.0 105 -44.61 -0.0154 0.0 12.000 -0.185 Vel = 3.75 105 20.30 2.203 0.0 10.000 13.143 K Factor= 5.60 to 120.0 0.0 0.0 0.0 106 -24.31 -0.0051 0.0 10.000 -0.051 Vel = 2.05 106 20.26 2.203 2T 27.277 6.000 13.092 K Factor= 5.60 to 120.0 0.0 27.277 0.0 107 -4.05 -0.0002 0.0 33.277 -0.006 Vel = 0.34 107 20.26 2.203 0.0 10.000 13.086 K Factor= 5.60 to 120.0 0.0 0.0 0.0 108 16.21 0.0024 0.0 10.000 0.024 Vel = 1.36 108 20.28 2.203 2T 27.277 4.500 13.110 K Factor= 5.60 to 120.0 0.0 27.277 0.0 43 36.49 0.0107 0.0 31.777 0.339 Vel = 3.07 0.0 36.49 13.449 K Factor= 9.95 34 -128.58 2.203 2T 27.277 18.500 20.232 to 120.0 0.0 27.277 0.0 109 -128.58 -0.1097 0.0 45.777 -5.022 Vel = 10.82 109 21.84 2.203 0.0 12.000 15.210 K Factor= 5.60 to 120.0 0.0 0.0 0.0 110 -106.74 -0.0777 0.0 12.000 -0.932 Vel = 8.98 110 21.16 2.203 0.0 12.000 14.278 K Factor= 5.60 to 120.0 0.0 0.0 0.0 111 -85.58 -0.0517 0.0 12.000 -0.620 Vel = 7.20 111 20.69 2.203 0.0 12.000 13.658 K Factor= 5.60 to 120.0 0.0 0.0 0.0 112 -64.89 -0.0310 0.0 12.000 -0.372 Vel = 5.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 9 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln, Total Pf Pn 112 20.41 2.203 0.0 12.000 13.286 K Factor= 5.60 to 120.0 0.0 0.0 0.0 113 -44.48 -0.0153 0.0 12.000 -0.184 Vel = 3.74 113 20.27 2.203 0.0 10.000 13.102 K Factor= 5.60 to 120.0 0.0 0.0 0.0 114 -24.21 -0.0050 0.0 10.000 -0.050 Vel = 2.04 114 20.23 2.203 2T 27.277 6.000 13.052 K Factor= 5.60 to 120.0 0.0 27.277 0.0 115 -3.98 -0.0002 0.0 33.277 -0.006 Vel = 0.33 115 20.23 2.203 0.0 10.000 13.046 K Factor= 5.60 to 120.0 0.0 0.0 0.0 116 16.25 0.0024 0.0 10.000 0.024 Vel = 1.37 116 20.25 2.203 2T 27.277 4.500 13.070 K Factor= 5.60 to 120.0 0.0 27.277 0.0 44 36.5 0.0107 0.0 31.777 0.339 Vel = 3.07 0.0 36.50 13.409 K Factor= 9.97 35 -128.67 2.203 2T 27.277 18.500 20.226 to 120.0 0.0 27.277 0.0 117 -128.67 -0.1098 0.0 45.777 -5.027 Vel = 10.83 117 21.83 2.203 0.0 12.000 15.199 K Factor= 5.60 to 120.0 0.0 0.0 0.0 118 -106.84 -0.0779 0.0 12.000 -0.935 Vel = 8.99 118 21.15 2.203 0.0 12.000 14.264 K Factor= 5.60 to 120.0 0.0 0.0 0.0 119 -85.69 -0.0518 0.0 12.000 -0.621 Vel= 7.21 119 20.68 2.203 0.0 12.000 13.643 K Factor= 5.60 to 120.0 0.0 0.0 0.0 120 -65.01 -0.0311 0.0 12.000 -0.373 Vel= 5.47 120 20.40 2.203 0.0 12.000 13.270 K Factor= 5.60 to 120.0 0.0 0.0 0.0 121 -44.61 -0.0154 0.0 12.000 -0.185 Vel = 3.75 121 20.26 2.203 0.0 10.000 13.085 K Factor= 5.60 to 120.0 0.0 0.0 0.0 122 -24.35 -0.0051 0.0 10.000 -0.051 Vel= 2.05 122 20.22 2.203 2T 27.277 6.000 13.034 K Factor= 5.60 to 120.0 0.0 27.277 0.0 123 -4.13 -0.0002 0.0 33.277 -0.006 Vel= 0.35 _ 123 20.21 2.203 0.0 10.000 13.028 K Factor= 5.60 to 120.0 0.0 0.0 0.0 124 16.08 0.0023 0.0 10.000 0.023 Vel = 1.35 124 20.23 2.203 2T 27.277 4.500 13.051 K Factor= 5.60 to 120.0 0.0 27.277 0.0 45 36.31 0.0106 0.0 31.777 0.336 Vel= 3.06 0.0 36.31 13.387 K Factor= 9.92 36 -126.96 2.203 2T 27.277 18.500 20.247 to 120.0 0.0 27.277 0.0 125 -126.96 -0.1071 0.0 45.777 -4.905 Vel = 10.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 10 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 125 21.94 2.203 0.0 12.000 15.342 K Factor= 5.60 to 120.0 0.0 0.0 0.0 126 -105.02 -0.0754 0.0 12.000 -0.905 Vel= 8.84 126 21.28 2.203 0.0 12.000 14.437 K Factor=5.60 to 120.0 0.0 0.0 0.0 127 -83.74 -0.0496 0.0 12.000 -0.595 Vel = 7.05 127 20.83 2.203 0.0 12.000 13.842 K Factor= 5.60 to 120.0 0.0 0.0 0.0 128 -62.91 -0.0292 0.0 12.000 -0.351 Vel = 5.30 128 20.57 2.203 0.0 12.000 13.491 K Factor= 5.60 to 120.0 0.0 0.0 0.0 129 42.34 -0.0141 0.0 12.000 -0.169 Vel = 3.56 129 20.44 2.203 0.0 12.000 13.322 K Factor= 5.60 to 120.0 0.0 0.0 0.0 130 -21.9 -0.0041 0.0 12.000 -0.049 Vel = 1.84 130 20.40 2.203 0.0 12.000 13.273 K Factor= 5.60 to 120.0 0.0 0.0 0.0 131 -1.5 -0.0001 0.0 12.000 -0.001 Vel = 0.13 131 20.40 2.203 2T 27.277 6.500 13.272 K Factor= 5.60 to 120.0 0.0 27.277 0.0 46 18.9 0.0032 0.0 33.777 0.107 Vel= 1.59 0.0 18.90 13.379 K_Factor= 5.17 37 -127.82 2.203 2T 27.277 18.500 20.354 to 120.0 0.0 27.277 0.0 132 -127.82 -0.1085 0.0 45.777 -4.966 Vel = 10.76 132 21.97 2.203 0.0 12.000 15.388 K Factor= 5.60 to 120.0 0.0 0.0 0.0 133 -105.85 -0.0765 0.0 12.000 -0.918 Vel = 8.91 133 21.30 2.203 0.0 12.000 14.470 K Factor= 5.60 to 120.0 0.0 0.0 0.0 134 -84.55 -0.0505 0.0 12.000 -0.606 Vel = 7.12 134 20.85 2.203 0.0 12.000 13.864 K Factor= 5.60 to 120.0 0.0 0.0 0.0 135 -63.7 -0.0299 0.0 12.000 -0.359 Vel = 5.36 135 20.58 2.203 0.0 12.000 13.505 K Factor= 5.60 to 120.0 0.0 0.0 0.0 136 -43.12 -0.0146 0.0 12.000 -0.175 Vel = 3.63 136 20.45 2.203 0.0 12.000 13.330 K Factor= 5.60 to 120.0 0.0 0.0 0.0 137 -22.67 -0.0044 0.0 12.000 -0.053 Vel= 1.91 137 20.40 2.203 0.0 12.000 13.277 K Factor= 5.60 to 120.0 0.0 0.0 0.0 138 -2.27 0.0 0.0 12.000 0.0 Vel = 0.19 138 20.41 2.203 2T 27.277 6.500 13.277 K Factor= 5.60 to 120.0 0.0 27.277 0.0 47 18.14 0.0029 0.0 33.777 0.099 Vel = 1.53 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 11 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18.14 13.376 K Factor= 4.96 38 -129.79 2.203 2T 27.277 18.500 20.609 to 120.0 0.0 27.277 0.0 139 129.79 -0.1116 0.0 45.777 -5.109 _ Vel = 10.92 139 22.05 2.203 0.0 12.000 15.500 K Factor= 5.60 to 120.0 0.0 0.0 0.0 140 -107.74 -0.0791 0.0 12.000 -0.949 Vel = 9.07 140 21.36 2.203 0.0 12.000 14.551 K Factor= 5.60 to 120.0 0:0 0.0 0.0 141 -86.38 -0.0525 0.0 12.000 -0.630 Vel = 7.27 141 20.90 2.203 0.0 12.000 13.921 K Factor= 5.60 to 120.0 0.0 0.0 0.0 142 -65.48 -0.0315 0.0 12.000 -0.378 Vel= 5.51 142 20.60 2.203 0.0 12.000 13.543 K Factor= 5.60 to 120.0 0.0 0.0 0.0 143 -44.88 -0.0157 0.0 12.000 -0.188 Vel = 3.78 143 20.47 2.203 0.0 12.000 13.355 K Factor= 5.60 to 120.0 0.0 0.0 0.0 144 -24.41 -0.0051 0.0 12.000 -0.061 Vel = 2.05 144 20.42 2.203 0.0 12.000 13.294 K Factor= 5.60 to 120.0 0.0 0.0 0.0 145 -3.99 -0.0002 0.0 12.000 -0.002 Vel= 0.34 145 20.41 2.203 2T 27.277 6.500 13.292 K Factor= 5.60 to 120.0 0.0 27.277 7.579 48 _ 16.42 0.0025 0.0 33.777 0.083 Vel = 1.38 0.0 16.42 20.954 K Factor= 3.59 21 -461.81 4.31 2E 27.874 32.670 23.502 to 120.0 0.0 27.874 0.0 31 -461.81 -0.0445 0.0 60.544 -2.692 Vel = 10.16 0.0 461.81 20.810_ K Factor= -101.23 28 -471.62 4.31 2E 27.874 32.670 23.408 to 120.0 0.0 27.874 0.0 38 -471.62 -0.0462 0.0 60.544 -2.799 Vel = 10.37 0.0 471.62 20.609 K Factor=-103.89 Computer Programs by Hydratec Inc. Route ill Windham N.H. USA 03087 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17716 48th Dr Permit#:762 Parcel#:31052100400104 Valuation:60000.00 OWNER APPLICANT CONTRACTOR Name:ARLINGTON CORPORATE AIR PARK Name:Commercial Fire Protection,Inc Name:Commercial Fire Protection,Inc Address: 17617 49TH PL NE HANGER B Address:17199 Bennett Rd Address: 17199 Bennett Rd City,State Zip:ARLINGTON,WA 98223 City,State Zip:Mount Vernon,WA 98273 City,State Zip:Mount Vernon,WA 98273 Phone: Phone:360-848-9093 ext 122 Phone:360-848-1533 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2012 STORIES: I CONST.TYPE: DWELLING UNITS. 0 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW I8.27. THIS APPLICATION 1S NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC[10/IRCI[0. LES TAX N(J rICE:Sales tax relat,id_ to construction and construction materials in the City of Arlington must be reported on your sales tax return form (anVcd'(-uv a Arlin n#310t. Y nature Print Name Date Released By ale CONDITIONS See redlined plans for additional requirements. Adhere to approved plans. THIS PERMIT AUTHOR[ZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0.00 Balance Due: $0.00 CALL FOR INSPECTIONS _ BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Print Form - ' FIRE SPRINKLER PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington,WA 98223• Phone(360)403 3551 • FAX(360)403 3447 THIS APPLICATION MUST BE ACCOMPANIED BY FIVE(5) SETS OF COMPLETE AND SCALED PLANS, FIVE(5) SETS OF HYDRALIC CALCULATIONS, FIVE(5) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: QM New Fire Sprinkler ®) Fire Sprinkler Add/Alt ® Underground Fire Line 17716 48TH DR Project Address: - Parcel ID#: Project Valuation: 159.811 Number of Heads: 202 Building Area(Sq Ft): 19.200 Owner: Abbatare, Inc. Phone Number: 360 474-1993 Address: 17617 49th Ave NE #B City.Arlington State: WA Zip Code 98223 Contact Person:Hans von der Hofen Phone Number: 360 474-1993 Cell Phone: Fax: E-mail: same as above Address: City: State: Zip Code: Contractor: Commercial Fire Protection, Inc. Phone Number: 360 848-9093 EXT 122 Address: 17199 Bennett Rd City:Mount Vernon State: WA Zip Code 98273 Contractor'sCOMMEFP132MM 08-16-16 License Number: Expiration:_ I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- s ed prop will accordance with the laws, rules and regulation of the State of Washington V0 1�5 ::1 Ap li Sign t je Date Print App scants Name Received FOR STAFF USE ONLY AUG 12 2015 } &r— CSC ermit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 04/08 sb Permit#: 762 Permit Date: 08/12/15 Permit Type: FIRE SPRINKLER Project Name: Abbatare Hanger Applicant Name: Commercial Fire Protection, Inc Applicant Address: 17199 Bennett Rd Applicant, City, State, Zip: Mount Vernon,WA 98273 Contact: Della Dellinger Phone: 360-848-9093 ext 122 Email: Scope of Work: Fire Sprinkler Valuation: 60000.00 Square Feet: 19200 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 08/17/2015 Permit Expires: 02/17/2016 Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31052100400104 17716 48th Drive NE CORPORATE AIR Storage Warehousing& rage Services PARK Sto Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Alarm& Eric Sigmen 3606612630 17199 Bennett Rd CONSTRUCTION COA 604 486 615 Detection CONTRACTOR Commercial Alarm& Eric Simen 3606612630 17199 Bennett Rd CONSTRUCTION Labor&PERFOSIS1850 Detection g CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status FA00.FIRE ALARM System not Monitored per Not 02/11/2019 FINAL current I.F.C.requirements. 12/07/2015 BUILDING Completed Plan Reviews Date Review Type Description Assigned To Review Status 08/12/2015 FIRE SPRINKLER See Redlined drawings BUILDING Attached Letters Date Letter Description 08/17/2015 Building Permit Notes Date Note Created By: 02/20/2019 Expired.Filed in address files.No final was done. Raelynn Jones 08/17/2015 Fees were collected at time of original permit per CY-1p Launa Black Uploaded Files Date File Name 08/17/2015 1237352-762 Issued Permit.pdf 08/12/2015 1231805-Fire SprinklerApplication.pdf