Loading...
HomeMy WebLinkAbout17716 48th Dr Ne_BLD712_2026 COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3) SETS OF CONSTRUCTION DRAWINGS, AND THREE (3) SETS OF FIXTURE SPECIFICATIONS(CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR IF APPLICABLE. Type of Permit: ❑ New Installation ❑ Addition/Alteration ❑ Industrial Project Address I �r h J � It 11�iG�. , Parcel ID#: Lot#: Subdivision: U I Project Description: Valuation: boo , 06 Owner: Nro%ElkPhone Number: -(26 -1 g1 D_ Address: VJY -sty: �� State: Zip Codes Contact Person: W cv-' 1 .e- Phone Number: Cell Phone E-mail: Address- City: State: Zip Code- CL Contractor:aQ1<_, (� Phone Number:s `J I Cell Phone: yZS^ Z3/_ZC61 E-mail: �� cn\�9L�nl�i. , v►.tC�`11['o�v. . Address:S—z _21si� Cit;G2"Q4U C Stated Zip Code; Contractor License Number: S PLO S C c) Expiration Date: � Please indicate number of fixtures: Water Closet —.L.— Floor Sink Sump Hose Bibb �_ Mit s�elaneouls 1_ Lavatory _ r4 Laundry Tub Washer ( _._ Water Heater l Grease Trap Urinal 3 Interceptor Sink �_ Med Gas Drinking Fountain_ Floor Drain ��' Dishwasher Backflow Shower �� Other 11 Page 2 of 3 ' COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone (360) 403-3551 PROPOSED BUILDING USE ® Commercial Addition/Alteration ❑ Restaurant ❑ Medical ❑ Automotive Based ❑ New Commercial ❑ Office Industrial ❑ Machine Shop ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Maker ❑ Dialysis Equip. ❑ Air washers ❑ Swimming Pools ❑ Fire Sprinkler ❑ Espresso Mach. ❑ Hydrotherapy Equip. ❑ Steam ❑ Hot Tub/Spa ❑ Sprinkler Generators w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Ice Machine ❑ Lawn Irrigation ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Coffee ❑ Well on Washers Urn/Espresso property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Aquarium ❑ DecorativeFountain ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes Q No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes ❑ No ® Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing, cooling)? ❑ Yes ❑ No Don't Know 5. Does your business require a NPDES permit? ❑ Yes ❑ No Don't Know I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- e ribed perty will be in accordance with the laws, rules and regulation of the State of Washington. A lica Sig ature Date ob-fes,b lam+' A v',- Print Applicanitf Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received Page 3 of 3 CITY OF ARLAGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17716 48th Dr Permit#: 712 Parcel#: 31052100400104 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name: ARLINGTON CORPORATE AIR PARK Name:Precision Airmotive Name: CJ's Plumbing Service Address: 17617 49TH PL NE HANGER B Address:17716 48th Dr NE Address: 5528 218th Ave NE City,State Zip:ARLINGTON,WA 98223 City,State Zip: Arlington,WA 98223 City,State Zip:Granite Falls,WA 98252 Phone: Phone:360-651-8282 Phone: 360-691-5159 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: CJ's Plumbing Service Address: Address: 5528 218th Ave NE City, State,Zip: City,State,Zip:Granite Falls,WA 98252 Phone: Phone: 360-691-5159 LIC#: EXP: LIC#: CJSPLPS9150D EXP: 9/4/2015 JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 10/IRCI 10. SAL T.4 N E: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return for and ?d C �#3 . t t C jVl�lS-t� lnc>/ v�sp ianature Print Name Date Released By l �te CONDITIONS THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION PERMIT FEES Date Description Fee Amount 6/24/2015 Plumbing Permit Base Fee $25.00 6/24/2015 Plumbing Permit Fee(Enter Fixture Fee) $276.00 6/24/2015 Plumbing Plan Review Fees $345.64 6/24/2015 Water Heater $25.00 Total Due: $671.64 Total Payment: $0.00 Balance Due: $671.64 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number, Type of Inspection being requested,and whether you prefer morning or afternoon COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3) SETS OF CONSTRUCTION DRAWINGS, AND THREE (3) SETS OF FIXTURE SPECIFICATIONS(CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR/F APPLICABLE. Type of Permit: ❑ New Installation ❑ Addition/Alteration ❑ Industrial Project Address: I I r �� if/1(.G^ Parcel ID#: Lot#: Subdivision: ff r� Project Description: Valuation: $ 115 I bob ° O_0 Owner: 4J('(Y\jkkia Phone Number:2 & — Address: l--.r�i U " - dtity: �( State:Zip Codes �aL Contact Person:.LOACIr." 16nV-` Phone Number: J���VS✓I - Cell Phone: E-mail: Address: City: State: Zip Code* aQr---, % �hnContractor: e Number: Cell Phone: NZS'— 2~3/_ALrK E-mail: h: Address: - ^Z �� Cit�G is�QA(c Stated--- Zip Code* Contractor License Number: O Z S IP L AP S 9( 5 0 0 Expiration Date: Please indicate number of fixtures: Water Closet �� Floor Sink Sump -Hose Bibb �_ Miscelianeous L_ Lavatory �CV Laundry Tub Washer ter Heater Grease Trap Urinal ✓ 3 Interceptor Sink ✓2_ Med Gas Drinking Fountain_ Floor Drain �/��' Dishwasher Backflow Showed �� Other Page 2 of 3 COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 PROPOSED BUILDING USE Commercial Addition/Alteration ❑ Restaurant ❑ Medical ❑ Automotive Based ❑ New Commercial ❑ Office [ Industrial ❑ Machine Shop ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Maker ❑ Dialysis Equip. ❑ Air washers ❑ Swimming Pools ❑ Fire Sprinkler ® Generators Steam ❑ ❑ Sprinkler ❑ Espresso Mach. ® Hydrotherapy Equip. Hot Tub/Spa w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Ice Machine ❑ Lawn Irrigation Fume Hoods Laboratory Equip. ❑ Pressure ❑ Coffee [3Well on ❑ ❑ Washers Urn/Espresso property ❑ Decorative [3Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Aquarium Fountain ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes 0 No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes ❑ No ® Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing, cooling)? ❑ Yes ❑ No 91 Don't Know 5. Does your business require a NPDES permit? ❑ Yes ❑ No 01 Don't Know I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- /d',ejcribedpNpert,WiI11 be in accordance with the laws, rules and regulation of the State of Washington. A' lica Sig ature Date Print Applicant4 Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received Page 3 of 3 1 COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This also includes replacement of a Hot Water Tank. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping being repaired is altered or replaced. PLUMBING PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings 2. New Multi-Family Buildings 3. Roof Drains and Overflow Systems 4. Tenant Improvements 5. Installation of Medical Gas Systems 6. Installation of Commercial Kitchen's and Deli's 7. Installation of Grease Traps 8. Installation of Grease Interceptors 9. Installation of Sumps 10. Installation of Cross Connection Backflow Devices SUBMIT THREE (3) COPIES OF THE FOLLOWING FOR PLUMBING PLAN REVIEW: ❑ Plumbing plans or drawings. (Minimum plan size is 18" X 24" scale, %" scale for details.) ❑ Provide one set of plumbing drawings maximum size 11" X 17" ❑ Size of sanitary and potable water systems. ❑ Location, type and specifications (cut sheets) of proposed fixtures and equipment. ❑ Riser diagram of waste and vent, potable water and rain water systems, including sizes. ❑ Medical gas piping riser diagram indicating type of gas, storage room and size of piping. ❑ Location and type of all backflow assemblies for each fixture. I hereby certify that I have read and examined this application and know the same to be true and correct and I am authorized to apply for this permit. Page 1 of 3 r � >= z a o omw O � � o ��o Vow a > m 9N W � wcc �o 0 ;WaZ V w C o. �u)z 0 u.. os � tm O j m 0 0 o 3 � 1 i r� CL Cl LU LL7 rl �- LL � I J LL L r i v P i v LU �r v low r IT T CL 1 C) LLA 1 n�) �10PA LAM Z i C> Vol rS cc. � 9 1 s I Al 3 � - 7x v� xA Sri OFFICE J CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR mmma ti m a ram`-n Cil VJ Q 7° J n 0 m Z ` D H D �- m 4 O 4 FOUNTAIN G`) � O O 0 N - = Z 0 �-u FTE- 0 m Ca m Z M 0 z Permit#: 712 Permit Date: 06/24/15 Permit Type: COMMERCIAL PLUMBING Project Name: Precision Airmotive Applicant Name: Precision Airmotive Applicant Address: 17716 48th Drive NE Applicant, City, State, Zip: Arlington,WA 98223 Contact: Alan Jesner Phone: 360-651-8282 Email: cjsplumbing@msn.com Scope of Work: New Plumbing Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/24/2015 Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31052100400104 17716 48th Drive NE CORPORATE AIR Storage Warehousing& rage Services PARK Sto Contractors Contractor Primary Contact Phone Address Contractor Type License License# CJ's Plumbing Service Chris Johnson 360-691-5159 5528 218thAve PLUMBING Labor and CJSPLPS795MB NE CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/03/2015 C20.BUILDING Approved FINAL Sprinkler system 1 st floor 09/01/2015 FS07.FIRE CPVC Approved 2nd floor 09/01/2015 BUILDING Approved SPRINKLER FINAL hard pipe to office area approved. Plan Reviews Date Review Type Description Assigned To Review Status 06/24/2015 COMMERCIAL BUILDING PLUMBING Fees Fee Description Notes Amount Plumbing Base Permit Fee $25.00 Mechanical Commercial Permit Table 4-7;Per Unit $276.00 Water Heater(Tank) $25.00 Plumbing Plan Review Fees $345.64 Plumbing Base Permit Fee Addition $25.00 Mechanical Commercial Permit Table 4-7;Per Unit Addition $72.00 Building Plan Review Table 4-2 Addition plan review $150.00 Mechanical Commercial Permit Table 4-7;Per Unit HWT $25.00 Total $943.64 Attached Letters Date Letter Description 06/24/2015 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/24/2015 CJ Plumbing Chris Johnson 55056301 cc $671.64 08/07/2015 ROCHELLE JOHNSON 55553225 cc $272.00 Outstanding Balance $0.00 Notes Date Note Created By: 02/20/2019 Expired.Filed in address files.No final was done. Raelynn Jones 08/03/2015 Adding Additional Restroom-1p Launa Black Uploaded Files Date File Name 08/03/2015 1214405-Restroom Addition Plan.pdf 06/24/2015 1156215-Precision Airmotive Application.pdf EO Z\*.-4 VA �I Received cc,DP AUG 03 2015 c