HomeMy WebLinkAbout18008 Cambridge Dr_BLD625_2026 • RESIDENTIAL PLUMBING / MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING/MECHANICAL INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 118008 Cambridge Dr Project Description: Ilike in kind furnace replacement Owner Al Weil Address: 118008 Cambridge Dr E-mail: alan.l.weil@boeing.com Phone (h) 360-403-7360 (c) Applicant: Address: Phone (h) 360-403-7360 (c) E-mail: Contractor Information Contractor Name: Nordstrom Heating &Air Inc. Company: Isame Address: 14717 87th Ave NE License Number: inordsha884jw Expiration: 04-16-16 Phone: 425-33504029 E-mail: nordstromha@comcast.net Plumbing Section (select all that apply) Bath/Shower Combo (4.0) Sink (1 .5) Shower (2.0) Lavatory (1.0) Clothes Washer Water Closet (2.5) Dishwasher (1.5) Water Heater Hose Bibb (2.5) Other (list) Proposed Water Piping Size: Proposed Piping Material: Proposed DWV Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: ® Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Please Attach Site Plan and Supporting Documents (PDF Only) ADD2B080A9V Submittal.pdf 4*of ie4w Siaffdaf-d ADD213080MV SPEC-1 A HEATING & AIR CONDITIONING TAG: EM Downflow/Horizontal Gas Furnace - Variable Speed - 2 Stage Heat ADD213080MV3VA 5/8" 17-1/2" 28" 16-1/4" 24-1/2" 19-5/8" 5/8" SIDE PANEL 112" CUTOUT FOR 5" SIDE PANEL CUTOUT HORIZONTAL FOR HORIZONTAL VENTING ' VENTING THROUGH THE CABINET 9-5/8" THROUGH 7/8" DIA. HOLES ' —' ` THE CABINET ELECTRICAL 3-1/2 5" j CONNECTION i 40" 7/8" DIA. K.O. 3 3/8 i ELECTRICAL CONNECTION 3/4" FLUE (ALTERNATE) OPENING 31 2-1/8" 16" D 2s-1/2" ` DO DOD 1-1/2" DIA. 0 0 0 D D 20 1/4" CONNECTION D D D D (ALTERNATE) 3/4" `. �15/16 12-3/8" � �D D D 0 101, DDDD 10" 19" 8-1/44 5-5/16" 1/2" 2-1/16"' 1-1/2" DIA. HOLE GAS CONNECTION 0 2013 American Standard Heating&Air Conditioning *DD2B080A9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING S4-3 S4-4 0.1 0.3 0.5 0.7 0.9 CFM 775 750 700 685 680 LOW ON ON TEMP.RISE 50 51 55 56 57 WATTS 85 110 140 170 185 HEATING CFM 865 840 820 795 770 1ST MEDIUM** ON OFF TEMP.RISE 45 46 47 48 50 STAGE WATTS 110 140 175 210 235 CFM 1010 980 970 940 915 HIGH OFF OFF TEMP.RISE 38 39 40 41 42 WATTS 160 190 230 260 285 CFM 1080 1060 1035 1010 995 LOW ON ON TEMP.RISE 55 56 57 59 60 WATTS 180 220 255 285 325 HEATING CFM 1190 1190 1170 1155 1140 2ND MEDIUM** ON OFF TEMP.RISE 50 50 51 51 52 STAGE WATTS 245 290 330 370 410 CFM 1345 1335 1320 1310 1275 HIGH OFF OFF TEMP.RISE 44 44 45 45 46 WATTS 330 380 425 475 505 *DD2B080A9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) S3-1 S3-2 S3-3 S3-4 0.1 0.3 0.5 0.7 0.9 LOW OFF ON OFF ON CFM 840 830 830 815 750 (350 CFM/TON) WATTS 105 135 160 220 225 2.5 NORMAL OFF ON OFF OFF CFM 970 950 940 925 900 (400 CFM/TON) WATTS 140 170 210 245 270 HIGH CFM 1085 1060 1045 1015 1000 (450 CFM/TON) OFF ON ON OFF WATTS 185 220 260 300 325 LOW ON OFF OFF ON CFM 1015 995 990 970 920 (350 CFM/TON) WATTS 155 190 230 260 285 3.0 NORMAL ON OFF OFF OFF CFM 1150 1140 1120 1100 1085 (400 CFM/TON) WATTS 215 250 305 335 370 HIGH CFM 1290 1290 1270 1260 1235 (450 CFM/TON) ON OFF ON OFF WATTS 300 340 390 425 475 LOW OFF OFF OFF ON CFM 1160 1150 1140 1115 1100 (350 CFM/TON) WATTS 220 265 320 345 385 NORMAL** OFF OFF OFF OFF CFM 1355 1340 1330 1320 1280 3.5** (400 CFM/TON) WATTS 330 380 425 470 510 HIGH OFF OFF ON OFF CFM 1360 1360 1315 1320 1280 (450 CFM/TON) WATTS 330 380 425 470 510 NOTES: 1.*First letter may be"A"or"T" 2.**Factory setting 3.Continuous Fan Setting:Heating or Cooling airflow is approximately 50%of selected Cooling value. 4.LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT&HUMID CLIMATE setting;NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting INDOOR BLOWER TIMING COOLING OFF- DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION NOMINAL- ignition. The FAN-OFF period is field selectable by dip switches AIRFLOW #2 and #3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit 5-OFF 6-OFF NONE SAME wiring diagram). 5-ON 6-OFF 1.5 MINUTES 100%' Cooling:The fan delay-off period is set by dip switches on the ECM Fan Control board connected to the Integrated Furnace 5-OFF 6-ON 3 MINUTES 50% Control. The options for cooling delay off is field selectable by dip switches #5 and #6. However, dip switch #1 on the Inte- 5-ON 6-ON "* 50 100% grated Furnace Control must be set to"ON"for cooling mode to function properly. *-This setting is equivalent to BAY24XO45 relay benefit The following table and graph explain the delay-off settings: **-This selection provides ENHANCED MODE,which is This selection provides a ramping up and ramping down a ramping up and ramping down of the blower speed to pro- of the blower speed to provide improved comfort,quietness,and vide improved comfort, quietness, and potential energy sav- potential energy savings. The graph below shows the ramping ings.See Wiring Diagram notes on the unit or in the Service process. Facts for complete wiring setup for ENHANCED MODE. The graph which follows, shows the ramping process. 100%if necessary 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF 1 I 7.5 I 3 minute minutes minutes General Data o TYPE Downf low/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS 2 HEAT EXCHANGER 1st Stage Input BTUH 52,000 Type-Fired Alum.Steel 1st Stage Capacity BTUH(I CS) 3 41,600 -Unfired 2nd Stage Input BTUH 80,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS) 3 63,000 ORIFICES—Main Temp.rise(Min.-Max.)°F. 35-65 Nat.Gas.Qty.—Drill Size 3—45 BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56 Diameter-Width(In.) 10 x 7 GAS VALVE Redundant-Two Stage No.Used 1 PILOT SAFETY DEVICE Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN.—WPh/Hz a 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5 FLA 7.7 Max.Overcurrent Protection(amps) 15 COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 112 Drive-No.Speeds Direct-2 DIMENSIONS H x W x D Motor HP PSC[Shaded Pole]-RPM 1/100/[1/145]-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2 FLA PSC[Shaded pole] 0.70/0.40/[0.23/0.201 WEIGHT FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 146/135 Type Recommended High Velocity Hi Vel.(No.-Size-Thk.)Shipped 2-14 x 20-1 in. O Central Furnace heating designs are certified by the American Gas Association Inc.Laboratories. O Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. ®The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heating BURNERS—Multi-port,in-shotburners will STYLING—Heavy gauge steel and"wrap- furnace designs are certified by the Ameri- give years of quiet and efficient service. All around" cabinet construction is used in can Gas Association for both natural and models can be converted to L.P.gas without the cabinet with baked-on enamel finish for L.P.gas. Limit setting and rating data were changing burners. strength and beauty. The heat exchanger established and approved under standard INTEGRATED SYSTEM CONTROL—Exclu- section of the cabinet is completely lined with rating conditions using American National sivelydesignedoperationalprogramprovides foil-faced fiberglass insulation. This results total control of furnace limit sensors,blowers Standards Institute standards. in quiet and efficient operation due to the , excellent acoustical and insulating qualities SAFE OPERATION—The Integrated Sys- gas valve, flame control and includes self of fiberglass. tem Control has solid state devices, which diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION AIR DELIVERY—The variable speed,direct- when the system is in the heating mode of — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas drive blower motor, with sufficient airflow employ a Hot Surface Ignition system,which valve and regulator provide extra safety. range for most heating and cooling require- eliminates the waste of a constantly burning ments, will switch from heating to cooling pilot. The integrated system control lights QUICK HEATING— Durable, cycle tested, speeds on demand from room thermostat. the main burners upon demand for heat heavy gauge aluminized steel heat ex- The blower door safety switch will prevent or from the room thermostat. Complete front changer quickly transfers heat to provide terminate furnace operation when the blower service access. warm conditioned air to the structure. Low door is removed. (Fan relay and 35VA control energy power vent blower,to increase ef- transformer is standard). a. Low energy power venter. ficiency and provide discharge of gas fumes b. Vent proving differential switch. to the outside, allows common venting with hot water heater. c us �.S�o I ntertek Since American Standard Heating&Air Conditioning has Library - a policy of continuous product and product data improve- Product Section Furnaces ment, it reserves the right to change specifications and design without notice. Product Furnace Technical Literature-Printed in U.S.A. Model ADD2-A9V Literature Type Submittal American Standard Sequence - Heating&Air Conditioning Date 07/13 6200Troup Highway File No. ADD2B080A9V-SPEC-1A Tyler,TX 75707 www.americanstandardair.com Supersedes ADD213080AW-SPEC-1 BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 625 Address: 18008 Cambridge Dr Contractor: Nordstrom Heating&Air Owner: WEIL ALAN L Date: 4/10/2015 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Furnace CO DETECTOR: © HEAT PUMP/AC UNIT: ❑ GAS PIPING: © DISCONNECT: ❑ DRIP LEG: ® SEISMIC: ❑ VENTING: ® 3" PAD: ❑ ACCESS: ® INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: Fx DUCTS: N/A L&I: Yes Date: 4/10/2015 Inspector: Kevin Olander CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18008 CAMBRIDGE DR Permit#: 625 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00866600001900 DATE OF ISSUANCE. Scope of Work:Like for Like Furnace Replacement Valuation: .00 OWNER APPLICANT CONTRACTOR WEIL ALAN L Nordstrom Heating&Air,Inc NORDSTROM HEATING&AIR INC 18008 CAMBRIDGE DR 4717 87th Ave 1059 State Ave. Ste. G ARLINGTON,WA 98223 Marysville,WA 98270 MARYSVILLE,WA 98270 360-403-7360 425-335-4029 LIC:601 764 617 EXP: 12/31/2024 LIC:NORDSHA772L2 EXP:06/26/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR NORDSTROM HEATING&AIR INC 4717 87TH AVE NE MARYSVILLE,WA 98270 425-335-4029 LIC#:NORDSHA884JW EXP: 4/16/2016 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. i/ 03/31/2015 Applicant Signature Date Building Official Date CONDITIONS Model#ADD2B080A9V3VA-AFUE=80% The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/18/2026 Forced Air Heat $25.00 09/18/2026 Mechanical Base $25.00 Total Due: $50.00 Total Payment: $50.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 625 Permit Date: 03/31/15 Permit Type: RESIDENTIAL MECHANICAL Project Name: Weil Applicant Name: Nordstrom Heating &Air, Inc Applicant Address: 4717 87th Ave Applicant, City, State, Zip: Marysville,WA 98270 Contact: Al Weil Phone: 360-403-7360 Email: alan.l.weil@boeing.com Scope of Work: Like for Like Furnace Replacement Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00866600001900 18008 CAMBRIDGE DR WEIL ALAN L 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# NORDSTROM 1059 State Ave. CONSTRUCTION HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR COA 601764617 NORDSTROM 1059 State Ave. CONSTRUCTION Labor&NORDSHA772L2 HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR Industries Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 03/31/2015 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/31/2015 Jason Nordstrom 54067913 cc $50.00 Outstanding Balance $0.00 Notes Date Note Created By: 03/31/2015 Model#ADD2B080A9V3VA-AFUE=80% Amy Rusko Uploaded Files Date File Name 04/10/2015 1040966-1008 Cambridge Dr.docx 03/31/2015 1024820-18008 Cambridge Specs.pdf 03/31/2015 1024818-18008 Cambridge Apnlication.pdf