HomeMy WebLinkAbout128 W Burke Ave Unit 1, 2, and 3_BLD601_2026 CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
- PHONE; (360)403-3551
BUILDING PERMIT
Address:128 W.Burke Ave Permit#:601
Parcel#:00461801700800 Valuation:628000.00
OWNER APPLICANT CONTRACTOR
Name:PERASSO II LLC Name:Rob Perasso Name:Rob's Electric Inc
Address:4405 103RD ST SE Address:4405 103rd Ave SE Address:4405 103rd Ave SE
City,State Zip:EVERETT,WA 98205 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258
Phone: Phone:425-334-6834 Phone:425-334-6834
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name: Name:
Address: Address:
City,State,Zip: City,State,Zip:
Phone: Phone:
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Multi-Family CODE YEAR: 2012
STORIES: 3 CONST.TYPE:
DWELLING UNITS: 3 OCC GROUP:
BUILDINGS: I OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED
THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO
WORKMEN'S COMPENSATION INSURANCE AND RC W 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID,
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:SaIns iny relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
an co d City li n# 04"
.54' / /fe
Signat re Print Name Date Released By Dific
CONDITIONS
Adhere to approved plans. Pending water supply (hydrant)fire protection.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
7/20/2016 Building Permit Fee $5,238.53
7/20/2016 Building Plan Review Fee 40$3, 5 04
7/20/2016 Furnace 40
7/20/2016 Gas Outlets Base Fee 1 to 5 $75.0
7/20/2016 Mechanical Permit Base Fee $30.00
7/20/2016 Park-Community MF $4, 7 .00
7/20/2016 Park-Mini MF $1,49 .00
1
7/20/2016 Plumbing Permit Base Fee 308.00
.00
7/20/2016 Plumbing Permit Fee(Enter Fixture Fee) $396.00
7/20/2016 State Building Code Surcharge Fee 0
.5$4
7/20/2016 State Surcharge per Dwelling $ . 0
7/20/2016 State Surcharge per Dwelling $2.00
,0
7/20/2016 Traffic Mitigation-City $5
7/20/2016 Water Heater 3250
$75.. 0
Total Due: $20,209.57
Total Payment: $0.00
Balance Due: $20,209.57
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
RESIDENTIAL PERMIT
APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE,
ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2)
SETS OF CONSTRUCTION DRAWINGS AND TWO (2)SETS OF STRUCTURAL CALCULATIONS. THE
APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS.
THE ZONING VERIFICATION CAN BE SUBMITTED PRIOR.
Date: 3 /-I /
Address: ? c;� ul &4-5 S d Plat: �'L,� / ? -�e.RiEt2- C� yp
Owner/Applicant: .b t�-r,cs 0 03� �-A- �� L_� 's V-S V�
Signature: ?920 S
Verification of accuracy and agreement to follow the City of Arlington Municipal Code(electronic is ok)
ENTAIL: a�'C�� "bSej,,4w, +tc. • ®mac
Phone: (h) V2�_— 371/ - (c) Va-s'- 3.3 0
Describe Proposal (include cross street):
Single-family Duplex Townhouse D;Addition Accessory structure
Tri /c'Jc
1. Proposed Area: 1 t Floor y�2 2"d Floor 2315 Garage /6Gq Total SF) y9Z�
ar'4 Ae 2161
2. Valuation (cost):
3. Contractor: 6`S cl ic- /it L Phone:
4. Address: G��/0 �s 103 0" Ayd S-L-z Uc- S-A✓ee lr elk P—SZ-5,51
5. License Number: CC o I terns 6S€ �<K to/ me Expiration: 2
Plumbing Section (continue filling out if plumbing is involved)
(Check all that apply and indicate the number of fixtures proposed)
Bath/Shower Combo (4.0) x 9 0 Sink (1.5) x
Shower(2.0) x 0 0: Lavatory (1.0) x
Clothes Washer (4.0) x 3 a Water Closet (2.5) x
El (1.5) x� Water Heater x 3
Hose Bibb (2.5) x (a 0: Other(list)
Rev 2013
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only-ACCA procedures for sizing cooling systems should be used to determine cooling
toads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30. The incorporated Insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated.for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
Perrasso Triplex-Unit 1 Architectural Design Associates,PS
Lots#8&49 Burke Ave. 2221 Everett Ave#104
Arlington,Washington Everett,WA.98201
Heating SVstem Type: *Forced Air Furnace C Heat Pump
To see detailed instructions for each section,place your cursor on the word'Instructions".
Design Temperature
Instructions — Design Temperature Difference(AT) 47
l Marysville_ AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 1,599
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 9.0 14,391
Glazinq and Doors U-Factor X Area = UA
Instructions 0.30 262 78.68
Insulation
Attic U-Factor X Area = UA
Instructions
R 49 0.026 918 23.87
•
Single Rafter or Joist Vaulted Ceilings U-Factor Area UA
Instructions No selection
Select R Value !,l I --
Above Grade Walls(see Figure 1) U-Factor Area UA
0.056 1,702 95.31
Floors U-Factor Area UA
Instructions R 30 0.029 1263 36.63
I ,
Below Grade Walls(see Figured U-Factor Area UA
Instructions
�-Select R-value .�,� No selection 0 ---
Slab Below Grade(see Figure 1) F-Factor Len th UA
Instructions
Li Select cnnditioninq No selection U
Slab on Grade(see Figured F-Factor Length UA
Instructions 0.540 64 34.56
.; R 10 perimeter �,
Location of Ducts
Instructions Unconditioned Space Duct Leakage Coefficient
`,., •�..,
1.10
Sum of UA 269.04
Envelope Heat Load 12,645 Btu/Hour
Figure 1. Sum ofUAXAT
Air Leakage Heat Load 7,305 Btu I Hour
VolumeX 0.6XATX.018
Above ti,agc Building Design Heat Load 19,950 Btu I Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 21,945 Btu I Hour
• Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 30,723 Btu I Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Auitding and Duct Heat Loss X 1.25 for Heat Pump
(07101113)
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
Perrasso Triplex-Unit 2 Architectural Design Associates,PS
Lots#8	 Burke Ave. 2221 Everett Ave#104
Arlington,Washington Everett,WA.98201
Heating System Type: *Forced Air Furnace CHeat Pump
To see detailed instructions for each section,place your cursor on the word"Instructions"
Design Temperature
Instructions Design Temperature Difference(AT) 47
Marysville __ AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
` Instructions Conditioned Floor Area(sq ft) 1,620
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 9.0 14,580
Glazing and Doors U-Factor X Area = UA
Instructions 0.30 228 68A8
Insulation
Attic U-Factor X Area = UA
Instructions i a 0.026 888 23.09
Single Rafter or Joist Vaulted Ceilings U-Factor Area UA
Instructions —� No selection
Select R Value •L.� ---
Above Grade Walls(see Figure 1) U-Factor Area UA
Instructions R-21 0.056 1.099 61.54
� �
Floors U-Factor Area UA
Instructions 0 029 1,284 3724
Below Grade Walls(see Figure 1) U-Factor Area UA
Instructions No selection 0 Select R-value ---
Slab Below Grade(see Figure 1) F-Factor Ler� UA
Instructions �'
Select conditiorn No selection nu � ."
Slab on Grade(see Figure 1) F-Factor Length UA
Instructions I R.10 Perimeter . 0.540 54 3456
Location of Ducts
Instructions Duct Leakage Coefficient
t .Unconditioned Space ' 1 10
Sum of UA 224.91
Envelope Heat Load 10,571 Btu/Hour
Figure 1. SumofUAXAT
Air Leakage Heat Load 7,401 Btu/Hour
VolumeX 06XATX 018
At��6r+d� Building Design Heat Load 17,972 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 19,769 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
Ducts in conditioned space:Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 27,676 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07101113)
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA
Manuals J and S.This calculator will calculate heatinq loads only.ACCA procedures for sizing cooling systems should be used to determine coolinq
loads.
The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of
0.30, The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
Program at(360)956-2042 for assistance.
Project Information Contact Information
Perrasso Triplex-Unit 3 Architectural Design Associates,PS
Lots H8&49 Burke Ave. 2221 Everett Ave#1 104
Arlington,Washington Everett,WA.98201
Heatinq System Type: *Forced Air Furnace OHeat Pump
To see detailed instructions for each section,place your cursor on the word'Instructions".
Design Temperature
Instructions Design Temperature Difference(AT) 47
l`irl i�'`�I i' • AT=Indoor(70 degrees)-Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area(sq ft) 1,712
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height(ft) 9.0 15,408
Glazinq and Doors U-Factor X Area = UA
Instructions 0,30 327 97.95
Insulation
Attic U-Factor X Area = UA
Instructions —R 49 — 0.026 958 24.91
Single Rafter or Joist Vaulted Ceilings U-Factor Area UA
Instructions No selection
Select R Value
Above Grade Walls(see Figure 1) U-Factor Area UA
R 21 _ 0.056 1,963 109.93
Floors U-Factor Area UA
Instructions 3 0.029 1.400 40.60
t _ il J
Below Grade Walls(see Figure 1) U-Factor Area UA
Instructions 1 No selection 0�Select R�� • ---
Slab Below Grade(see Figure 1) F-Factor Len th UA
Instructions No selection
._Select conditioning ! ---
�ti�
Slab on Grade(see Figure 1) F-Factor Length UA
Instructions 0 540 62 33.48
R 10 Perimeter •I ,
Location of Ducts
Instructions I 1 Duct Leakage Coefficient
1 Unconditioned Space •l I 1 10
Sum of UA 306.87
Envelope Heat Load 14,423 Btu/Hour
Figure 1. SumofUAXAT
Air Leakage Heat Load 7,821 Btu/Hour
VolumeX 0.6XATX.016
nnovrc,,c. Building Design Heat Load 22,244 Btu/Hour
Air Leakage+Envelope Heat Loss
Building and Duct Heat Load 24,468 Btu/Hour
Ducts in unconditioned space:Sum of Building Heat LossX 1 10
Ducts in conditioned space:Sum of Building Heal Loss X 1
Maximum Heat Equipment Output 34,255 Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heal Pump
(07y01/13)
Permit#: 601
Permit Date: 03/02/15
Permit Type: MULTI-FAMILY
Project Name: Perasso Triplex
Applicant Name: Rob Perasso
Applicant Address: 4405 103rd Ave SE
Applicant, City, State, Zip: Lake Stevens, WA 98258
Contact: Rob Perasso
Phone: 425-334-6834
Email: rob@robselectricinc.com
Scope of Work: 3 Story Triplex Townhouse
Valuation: 628000.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 09/13/2016
Permit Expires:
Permit Form Type:
Civic Plus Number:
Status: COMPLETE
Assigned To:
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
00461801700800 128 W BURKE AVE,UNIT PERASSO II LLC 910 Undeveloped
1,2&3 (Vacant)Land
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Rob's Electric Inc Rob Perasso 425-334-6834 4405 103rdAve CONSTRUCTION ROBSEI*IO1ML
SE CONTRACTOR
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
04/18/2017 C20.BUILDING Separation walls 2 layers 04/18/2017 BUILDING Approved
FINAL gyp both sides triplex only.
Corrections-
03/16/2017 C09.FRAMING Pre-framing inspection.will 03/16/2017 z.Rick Karns Needs
re-call.
reinspection
C20.BUILDING Party walls inspected one
03/10/2017 FINAL s
ide sheathed ok to insulate. 03/09/2017 BUILDING Approved
KO.3/10/17
Shear inspection-add galv.
02/21/2017 Inspection nails to bottom plate 02/21/2017 z.Rick Karns Approved
throughout.Add nails to
various locations.
02/01/2017 C20.BUILDING Roof sheathing Approved 01/31/2017 BUILDING Approved
FINAL 1/31/17 KO.
12/01/2016 Inspection Floor slab insulation and 11/30/2016 BUILDING Approved
vapor barrier approved KO.
10/20/2016 C20.BUILDING Approved
FINAL
Plan Reviews
Date Review Type Description Assigned To Review Status
03/02/2015 BLD Ok to issue pending water supply(hydrant)fire protection. z.Christopher Young
Fees
Fee Description Notes Amount
Park-Community MF Multi-family $4,491.00
Park-Mini MF Multi-family $1,308.00
Traffic Mitigation-SF Single Family split fee in half with duplex $5,032.50
Building Permit Table 4-1 628K $5,238.53
Gas Piping/Units Enter#of units x3 $30.00
Mechanical Base Permit Fee x3 $75.00
Plumbing Base Permit Fee x3 $75.00
Mechanical Commercial Permit Table 4-7;Per Unit $396.00
State Surcharge-add'1 DU Residential Additional Units $2.00
Building Plan Review Table 4-2 $3,405.04
State Surcharge- 1st DU Residential- 1st Unit $4.50
State Surcharge-add'l DU Residential Additional Units $2.00
Water Heater(Tank) x3 $75.00
Forced Air Heat fee per Btu x3 $75.00
Total $20,209.57
Attached Letters
Date Letter Description
03/19/2015 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
09/13/2016 Robert Perasso 61311593 cc $20,209.57
Outstanding Balance $0.00
Notes
Date Note Created By:
03/02/2017 Water connection has not had final inspection from the Water Department. Kristin Foster
Uploaded Files
Date File Name
09/13/2016 1839593-601 Issued Permit.pdf
03/02/2015 979258-128 W Burke Ave-Triplex Application.pdf