Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17127 Smokey Point Blvd_BLD435_2026 (3)
5. Sta ntec July 21,2014 File:185750241.300.0300 Attention: Mr.Jose Rios 7-Eleven,Inc. P.O.BOX 711 Dallas,TX 75221 Dear Mr.Rios, Reference:Limited Asbestos Survey Report Stantec Consulting Services,Inc.(Stantec)appreciates the opportunity to provide you with the following limited asbestos survey report. The survey was performed at the site reference above on July 8, 2014. The purpose of this survey was to evaluate the presence of asbestos-containing materials (ACMs) that would require special handling and/or disposal in accordance with applicable federal, state, and local regulations. The survey findings and recommendations are provided below. BACKGROUND The structure consists of a metal canopy covering approximately 986 square feet over two small gasoline dispenser islands, associated with the 7-Eleven convenience store located in Arlington, Washington. The exterior of the dispenser island canopy is made up of pre-finished metal panels. The roof consists of pre- finished metal panels. There are two steel-beam supports near the center of the dispenser island canopy. Access to the site was provided by a 7-Eleven store employee on July 8,2014.A walk-through inspection of the entire dispenser island canopy including 2 separate gasoline pumps was performed by Ms. Deitrie Hanson, Geologic Project Specialist and AHERA Building Inspector(Accreditation #143266) on July 8, 2014 in order to identify which building materials may be suspect-asbestos containing materials (SACMs). An aerial inspection of the top of the dispenser island canopy was completed by reviewing aerial photographs of the top of the canopy roof. After identifying SACMs, bulk samples were collected, placed in plastic bags, and numbered according to the corresponding asbestos bulk sample logs. Care was taken to decontaminate tools between sampling to avoid cross-contamination. No insulation was found. No heating or ventilation system was encountered. No plumbing systems were found. No interior construction finishes or flooring was found. The electrical system is a single wire system through a conduit. No bulk samples were taken of the electrical system as it was turned on. SUSPECT ASBESTOS CONTAINING MATERIALS Sampling and Analysis A total of 3 bulk samples were collected and analyzed by Polarized Light Microscopy(PLM)in accordance with the Environmental Protection Agency (EPA) "Method for the Determination of Asbestos in Bulk Building Materials" (EPA/600/R93/116, July 1993)• Analysis was performed by EMSL Analytical, Inc. laboratory Design with community in mind (3 July 21,2014 Mr.Jose Rios Page 2 of 3 Reference: Limited Asbestos Survey Report located in Cinnaminson,New Jersey. This laboratory is accredited by the National Institute of Standards and Technology's National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 101048-o). This laboratory is accredited by the American Industrial Hygiene Association (AIHA Lab ID 100194) under the Industrial Hygiene Laboratory Accreditation Program (IHLAP) for bulk asbestos analysis. The laboratory is also certified by the New York State Department of Health's Environmental Laboratory Approval Program (NYS ELAP 1o872) and by the New Jersey Department of Environmental Protection (NJ DEP 03036). A summary of the laboratory analytical results are included in the table below. For the purpose of this report, material with any detectable concentration of asbestos are considered positive. The Stantec Asbestos Bulk Sample Log form and laboratory analytical results are included as an attachment to this letter report as well as a sample location diagram. Findings Table 1 below provides a summary of the suspect materials identified and sampled during this survey. Table 1—Asbestos Bulk Sample Results Sample No. Homogeneous Location of Asbestos EPA Quantity Condition Material Material Content Category (Analytical Method) o1A,o1B, Black Around base ND(PLM) NA 23 LF Damaged 01C Caulking of 2 gasoline dispensers Materials in BOLD are identified as being positive for asbestos ND=Non-Detect PLM=Polarized Light Microscopy SF=Square Feet LF=Linear Feet NA=Not Applicable Upon completion of the survey and review of the analytical laboratory data,the following materials found at the 17127 Smokey Point Blvd.,Arlington,WA,dispenser island canopy did not contain asbestos. RECOMMENDATIONS It is recommended that asbestos-containing materials be removed by a licensed abatement contractor prior to renovation,refurbishing, or demolition activities. No asbestos containing materials were found at the time of inspection on July 8, 2014 prior to demolition of the dispenser island canopy. If SACMs are encountered, contract personnel are responsible for notifying the contact of the owner, sampling and sending the material to a NVLAP-accredited laboratory to determine if the suspect material contains asbestos or not,consulting the inspection report after analysis is performed, and ensuring that all employees and contractors are informed and advised of the location and type of materials that contain asbestos. If hidden or covered SACMs are discovered during demolition of the dispenser island canopy, they must be treated as asbestos-containing materials unless determined otherwise by a NVLAP-accredited laboratory. Design with community in mind (3 July 21,2014 Mr.Jose Rios Page 3 of 3 Reference: Limited Asbestos Survey Report A copy of this report should be kept on the site during any asbestos abatement, renovation, or demolition activities. LIMITATIONS Reasonable efforts have been made by Stantec personnel to locate, sample, and/or identify SACMs. Access to the underground utilities was not possible. For any facility, the existence of unique or concealed materials and debris is a possibility. In addition, sampling and laboratory analysis constraints typically hinder the investigation. Stantec does not warrant, guarantee, or profess to have the ability to locate or identify all hazardous materials in a facility. The intent of this report is to be used in planning for this project only and is based on the scope of work provided to Stantec by the 7-Eleven,Inc. Should the scope of the underground storage tank system removal project change, Stantec recommends that an additional investigation,including but not limited to,a review of the revised scope of work,be performed to determine if hazardous material will be impacted. This report is not intended to be a bidding document. Quantities of materials identified are estimates only and would need to be verified. Stantec attempted to access all areas of the structure; however, if during the course of the demolition project SACMs are discovered that are not included with this report,those materials should be treated accordingly until additional sampling, analysis, and/or assessment can be performed. Additionally, the passage of time may result in a change in the environmental characteristics at the site. This report does not warrant against future operations or conditions that could affect the recommendations made. The results, findings, conclusions, and recommendations expressed in this report are based on conditions that were observed during Stantec's inspection of the site and test results provided by EMSL Analytical, Inc. These observations are time dependent, are subject to changing site conditions, and revisions to federal,state,and location regulations. Reliance on this letter report by Third Parties shall be at the Third Party's sole risk. If you have any questions regarding this report or require further clarification, please do not hesitate to contact Stantec personnel identified below. Respectfully submitted, Stantec Consulting Services Inc. Je4�- c X-� Deitrie Hanson Paul Fairbairn Geologic Project Specialist Project Manager Phone:(425)869-9448 ext.157 Phone:(425)869-9448 ext.143 Fax:(425)869-1190 Fax:(425)869-1190 Deitrie.hanson@stantec.com Paul.fairbairn@stantec.com Attachments: Laboratory Analytical Results Asbestos Bulk Sample Logs Figure 1: Site Location Map Figure 2: Sample Location Map Employee Certification Design with community in mind EMSL Analytical, Inc. EMSL Order: 041419581 200 Route 130 North,Cinnaminson,NJ 08077 CUstomerlD: SEC058 Phone/Fax: (800)220-3675/(856)786-5974 CustomerPO: htti)://www.EMSL.com cinnasblab(cD.EMSL.com ProjectlD: Attn: Deitrie Hanson Phone: (425)869-9448 Stantec Fax: (425)869-1190 11130 NE 33rd Place Received: 07/10/14 9:20 AM Suite 200 Analysis Date: 7/16/2014 Collected: 7/8/2014 Bellevue, WA 98004 Project: 185750241.300.0300/7-11 #21341/17127 Smokey Point Blvd,Arlington,WA 98223 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 01A SW corner of Black 100% Non-fibrous(other) None Detected dispenser#2- Non-Fibrous 041419581-0001 Caulking-Black- Homogeneous On Base Edge of Dispensers 01B NW corner of Black 100% Non-fibrous(other) None Detected dispenser#4- Non-Fibrous 041419581-0002 Caulking-Black- Homogeneous On Base Edge of Dispensers 01C NE corner of Black 100% Non-fibrous(other) None Detected dispenser#3- Non-Fibrous 041419581-0003 Caulking-Black- Homogeneous On Base Edge of Dispensers i Analyst(s) Jillian Yurick(2) Stephen Siegel, CIH, Laboratory Manager Quynh Vu(1) or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced,except in full,without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP,NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy,precision and uncertainty data available upon request.Unless requested by the client,building materials manufactured with multiple layers(i.e.linoleum,wallboard,etc.)are reported as a single sample.Reporting limit is 1% Samples analyzed by EMSL Analytical,Inc.Cinnaminson,NJ NVLAP Lab Code 101048-0,AIHA-LAP,LLC-IHLAP Lab 100194,NYS ELAP 10872,NJ DEP 03036,PA ID#68-00367 Initial report from 07/16/2014 16:51:21 Test Report PLM-7.28.9 Printed:7/16/2014 4:51:21 PM THIS IS THE LAST PAGE OF THE REPORT. 1 OrderID: 041419581 EMSL Analytical, Inc. Asbestos Chain of Custody 200 Route 130 North EIASL Order Number (Lab Use Only). [-- Cinnaminson, NJ 08077 EMSL ANALYTICAL.INC. O \ PHONE; 1-800-220-3675 FAX (856)786-5974 EMSL-Bill to; P.I. Different Same Company :$tanteC Consulting Services, Inc. if Bill to is Dill no a instructions in Common s" Street:11130 NE 33rd Place Suite 200 Third Pafty Bdlir requires written authorization from third party city:Bellevue State/Province:WA Zi /Postal Code:98004 Country:United States Report To (Name):Deitrie Hanson Tele hone#:(425) 869-9448 Email Address: deitrie.hanson@stantec com Fax#: (425)869-1190 Purchase Order: Project Name/Number:185750241.300.0 00 7-11 #21341 Please Provide Results: IFAX I �/ E-mail I Imail U.S.State Samples Taken:WA Connecticut Samples: ❑ Commercial ❑Residential Tt maround Time TAT Options*—Please Check ❑ 3 Hour ❑ 6 Hour I ❑ 24 Hour I El 48 Hour I ❑ 72 Hour I ❑ 96 Hour 19 1 Week ❑ 2 Week 'For TEM Air 3 hr through 6 hr,please call ahead to schedule'There is a premium charge for 3 Hour TEM AHERA or EPA Level11 TAT. You will be asked to sign an authorization form for this service. Analysis com leted in accordance with EMSL's Terms and Conditions located in the Analytical Price Guide. PCM-Air ❑ Check if samples are from NY TEM—Air ❑4-4.5hr TAT(AHERA only) TEM-Dust ❑ NIOSH 7400 ❑ AHERA 40 CFR, Part 763 ❑ Microvac-ASTM D 5755 ❑ wi OSHA 8hr. TWA ❑ NIOSH 7402 ❑Wipe-ASTM D6480 PLM -Bulk(reporting limitl ❑ EPA Level II ❑ Carpet Sonication (EPA 600/J-93/167) ❑■ PLM EPA 600/R-93/116(<1%) ❑ ISO 10312 Soil/RockNermiculite ❑ PLM EPA NOB (<1%) TEM-Bulk ❑ PLM CARB 435-A(0.25%sensitivity) Point Count ❑TEM EPA NOB ❑ PLM CARB 435-B(0.1%sensitivity) ❑400(<0.25%)❑ 1000(<0.1%) ❑ NYS NOB 198.4(non-friable-NY) ❑TEM CARB 435-B(0.1%sensitivity) Point Count w/Gravimetrlc ❑ Chatfield SOP ❑TEM CARB 435-C(0.01%sensitivity) ❑400(<0.25%)❑ 1000(<O.1%) ❑TEM Mass Analysis-EPA 600 sec.2.5 ❑TEM Qual.via Filtration Technique ❑ NYS 198.1 (friable in NY) TEM—Water: EPA 100.2 ❑TEM Qual.via Drop-Mount Technique ❑ NYS 198.6 NOB (non-Enable-NY) Fibers>10pm ❑Waste ❑ Drinking Other: ❑ NIOSH 9002 <1% All Fiber Sizes ❑Waste ❑ Drinking ❑ ❑ Check For Positive Stop—Clearly Identify Homogenous Group Filter Pore Size Air Samples): E10.81im E10.461im Samplers Name: DeItrie Hanson Samplers Signature: Volume/Area(Air) DatelTime Sample# Sample Description HA# Bulk Sampled (see attached sample log) o n n in i iLn Client Sample#Is): 01R 07 1G Total#of Samples: Relinquished (Client): Date: -* 18 201 Time: 152- Received (Lab); Date: p 1 Time: Lo Comments/1 ecial In , 0ion : lease e-mail ana y cal report to ei ne. anson stantec con, Page 1 of 2 pages 3 �Q Page 1 Of 2 OrderID: 041419581 3 o C NNA �I ON, J. V lf� N tV a N = p a `n T01 JUL 10 A l 0 eM-,pq F w � ci Q cad c +3 a cot n v� 12 z ' C (D CN 0. c ` O 0 Qi m o N N W tit tw O za' � y p ON N -4411 m V"> N c 1—4 rio v Q O o H w S °- A a w m N V � ° W ' z x x x N o b a) w u' c V to 2 j Z O O 0 }± C i C Page 2 Of 2 �^ 193RD ST NE Q, D Aj_ m w m 'J' rrrr LU m_ oN� w ; , 18$T_H ST NE 1'8 C Cz m -- j �O� m l~!1Ln 184TH ST NE m(n �4 4 �4~ Arlin ton 186TH S NEB m 181ST P,L NtE Mung z II z + 180- �179TN ST Totem Park 182ND PL NEB 177T PLANE z Ln Lu Ln w 206 r!75r N �I —¢ � _ ���, 4T H PL NE 0 m z I— w O z m English N' z F Smokey_Point •Lakewood =z 531 r w � N � � SITE LOCATION Qr _ t" x `y 206 0 D Ln m rn z m m E G � m L z, F_J = o a Fj C w m z O m 56TH�S,T_N E 2� w w 152ND ST NE lul �rz z LU X7- w 1/2 0 1 North SCALE(MILES) 1000 0 1000 2000 3000 4000 5000 SCALE(FEET) WASHINGTON REFERENCE:USGS 7.5 MINUTE QUADRANGLE,ARLINGTON WEST,WASHINGTON FOR: � FIGURE: ELEVEN Sta ntec SITE LOCATION MAP 7 STORE NO.21341 17127 SMOKEY POINT BOULEVARD ARLINGTON,WASHINGTON 11130 NE 33RD PLACE,SUITE 200 BELLEVUE,WASHINGTON JOB NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: DATE: PHONE:(425)869-9448 FAX:(425)869-1190 1 185750241 MDR DH PF JULY 2014 FILEPATH:M:\_00 OTHER OFFICES\01-REDMOND\7-11\21341\FIG-1-SITE LOC.dwg I Layout Tab:Layoutl I Drafter:MiRamirez I Jul 21,2014 at 13:57 ---w----w----w- 172ND ST NE I VENT 3 LINE CB -----SD-----SD-----SD-- c6 z o G) FORMER m _ SIDEWALK ' ®? 3 CANOPY CBS _ — �— — w x t CB @ TRASH J ENCLOSURE • o1A FORMER ' Y �. 01B DISPENSERS m i 01C CB z I cB 1 (o i o I I O 7-ELEVEN STORE 0100 1 �I �0 I #21341 ' W ENTRANC 1 1I i ' 1 I 9. Y I I 1O11� J 0 l0J 0 I � ` I 2 I FORMER U) i TANK FIELD IU) I �M e 7-11 STORE SIGN LEGEND: 01A • NON-ACM(ABESTOS CONTAINING MATERIAL) 0 30 60 APPROXIMATE SCALE IN FEET FOR: � FIGURE: ELEVEN Stantec SAMPLE LOCATION MAP 2 STORE NO.21341 17127 SMOKEY POINT BOULEVARD 11130 NE 33RD PLACE,SUITE 200 ARLINGTON,WASHINGTON BELLEVUE,WASHINGTON JOB NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: DATE: PHONE:(425)869-9448 FAX:(425)869-1190 185750241 MDR DH PF JULY 2014 FILEPATH:M:\_00 OTHER OFFICES\01-REDMOND\7-11\21341\FIG-2 SAMPLE LOC.dwg I Layout Tab:8x11 I Drafter:MiRamirez I Jul 21,2014 at 13:28 i i 0 I • i y; �' • • • , i 1 r �- r 1 - �' v1 • • 0 CD _ 0 •• - 1 ► • , • y • r - cn I/ ccn rots CD Fn • �. •. i , CD �. .. co - • /J r: r r'1 • • , cl • • cr • D _% — z • • � c •• • Jw cn • • ` .. 1 • co 1 ` . • o • • • -11 _ l •• ' / !p • • _� t,- 1� . i SCOPE OF WORK PROPERTY INFORMATION G.C.=GENERAL CONTRACTOR0 OWNER SITE ADDRESS: 17127 SMOKEY PT BLVD,ARLINGTON, OT =OTHERS WA 98223 1D o.T. REMOVE 2-EXISTING DISPENSERS. SNOHOMISH COUNTY PARCEL NUMBER:31052800202200 172 N D ST NE @ c.a DEMOLISH EXISTING GASOLINE DISPENSER TOWNSHIP,RANGE,SECTION:T31 R05 S28 CANOPY SUPPORT COLUMNS,FOOTINGS AND CONCRETE PUMP ISLANDS. LEGAL DESCRIPTION OF PROJECT SITE:SECTION 28 3 c.a SAW CUT,BREAK,AND REMOVE CONCRETE TOWNSHIP 31 RANGE 05 QUARTER NW-N 165.04FT OF O SURFACE OVER UNDERGROUND STORAGE W 180.05FT AS MEAS AT R/A TO&PLW N&W LNS OF TANKS(USTs). THOF OR RD&ALSO EXOC FOR RD TH PTON LY WLY OFT @ c.a SAW-CUT,BREAK,AND REMOVE CONCRETE FDL BAAP ON S LN N 50.01 FT DIST 75FT ELY FIR AT DISPENSER ISLAND SE OF —W W--- -W———— CONCRETE DEBRIS.REMODVE OIL-WATER ER CONTACT INFORMATION —W—--—W—-- —W————W———— SEPARATOR AND CAP LINE TO SANITARY W_—— SEWER,IF APPLICABLE. PROJECT OWNER: JOSE RIGS ® c.a EXCAVATE AND STOCKPILE UST OVER BURDEN MANAGER ENVIRONMENTAL SERVICES SOIL ON 6-MIL VISQUEEN SHEETING.COVER 7-ELEVEN INC STOCKPILE WITH VISQUEEN. PO BOX 711 DALLAS,TX 75112 VENT @ c.a INERT AND REMOVE 3-EXISTING 12,000GALLON JOSE.RICS@711.COM ___ USTs.EXISTING PRODUCT,VAPOR,AND VENT CONTACT PERSON: LINE —SD —SD-----SD---- PIPING,PERFORM UST CLEANING, PAUL FAIRBARIN CB —SD-----gD—___ TRANSPORTATION,AND DISPOSAL. STANTEC CONSULTING SERVICES W (2) c.a REMOVE EXISTING PRODUCT PIPING LINES. 11130 NE 33RD PLACE SUITE 200 CB �_/ BELLEVUE,WA 98004 V ® c.a REMOVE 3-EXISTING VENT RISERS AND VENT Paul.Fairbarin@Stantec.com z LINES AND UNDERGROUND PIPING. 425-289-7343(work) O = 206-369-8383(cell) SIDEWALK cc Q9 c.a REMOVE EXISTING ELECTRICAL CONDUITS ENGINEER: CANOPY m FROM SUB-PANEL TO TANK TURBINE&FILL MARC SAUZE,P.E. LL - z x SUMPS,ANNULAR DISPENSER,AND ALL LOW STANTEC CONSULTING SERVICES (785 SF) CB - - W _ VOLTAGE SENSORS. 11130 NE 33RD PLACE SUITE 200 o' - ® BELLEVUE,WA 98004 1 c.a EXCAVATE UST BASIN IN ORDER TO REMOVE Marc.Sauze[(rDDStantec.com ANY PETROLEUM CONTAMINATED SOIL(PCS)IF 425-86auz @ eat 172(work) CB ENCOUNTERED.STOCKPILE PCS ON 425-894-2329(cell) VISQUEEN AND COVER WITH VISQUEEN UNTIL SOIL IS TRANSPORTED OFFSITE FOR DISPOSAL AT SEPARATE FACILITY. OVER EXCAVATE AREAS OF USTs AND DISPENSER ISLAND IN ORDER TO N IL IF CB I TRASH E COUN RED•REUSE SOIL AS BACKFIOVE CONTAMINATED OLL IF s TI ' DISPENSERS ' ENCLOSURE CLEAN. 3T © c.a PERFORM BACKFILL AND SURFACE RESTORATION ACTIVITIES(SEE SITE GRADING 'I 2 4 AND RESTORATION PLAN).REGRADE SO 7222 I STORMWATER FLOWS INTO EXISTING STORM \ I 7 11 DRAINS ryJM� I I VICINITY MAP Q I W 3 I CB LEGEND € Sd K,dzle B Kids 174V PI NE y0 CB om�O — EXCAVATION BOUNDARY� rO� PROPERTY BOUNDARY 172ND ST NE OTELEVEN STOREO J _ 1 3 5 6 9 - WATER LINE Lu Y #21341 -ss----- SEWER LINE Ye 3 I -SU- STORM LINE nvi Ne � Nw naa O O O 1 ---- x 169�n 5i NE 0 W I MW 4 Enxd�ool and KL_ " ' I ENT ANC I I I I I � MONITORING WELL Y PREPARED BY: w q I (4 I STORM CATCH BASIN(CB) c O I I ( �O� J UNDERGROUND STORAGE TANK(UST) 3 TANK FIELD DEMOLITION LEGEND Stantec (1,300 SF) CA ASPHALT SAWCUT 11130 NE 33RD PLACE SUITE zao �— \ \ BELLEVUE,WA 98004 m 3-12,000 GAL SINGLE PHONE:425-289-7343 FAX:425-869-1190 j CB D WALLED STEEL USTs FOR: I GENERAL NOTES A INSTALLED IN 1980 ELEVEN f/1 I 1. CONSTRUCTION ACTIVITIES WILL COMPLETED IN d I ACCORDANCE WITH CITY OF ARLININ COMPLETED PLANNING AND 3 DEVELOPMENT SERVICES REQUIREMENTS. 7-ELEVEN#21341 7-11 STORE SURFACE AREA TO BE 2. ALL HAZARDOUS MATERIALS TO BE TRANSPORTED 17127 SMOKEY PT BLVD $ I SIGN THREAT TO L PUBLIC G THE'.NEED FOR MAINTENANCE AND ARLINGTON,WA 98223 I SAWCUT REMOVED AND 3. CONTRACTOR SHALL INSTALL PROTECTIVE CHAIN LINK TITLE: q I I I E REPLACED WITH ASPHALT FENCING FAR A TO BE DEMOLISHED PER LOCAL ti SITE DEMOLITION PLAN i I I (2,520 SF) 4. CONTRACTOR SHALL ENSURE THAT ALL STORM DRAINS AND CATCH BASINS BE PROTECTED FROM UST SYSTEM REMOVAL SEDIMENTATION RUN-OF OR OFF.ANY ACCUMULATION PROTECTIONOF SED b FILTER FABRIC SHALL BE TREMOVED IMMEDIATELY WITHOUT WATER AND Ly DISPOSE OF ON-SITE OR REMOVED FOR DISPOSAL AT AN OFFSITE FACILITY. DRAWN BY: DESIGNED BY: Q 5. DO NOT ALLOW VEHICLES TO TRACK SEDIMENTATION BLG w OFFSITE. CHECKED BY: APPROVED BY: 0 6. DEMOLITION TO BE PERFORMED BY HANDWRECKING AND pF a DOZER. 7. CONTRACTOR TO PERFORM ALL WORK IN ACCORDANCE PROJECT NUMBER: SCALE: Q TO FEDERAL,STATE,AND LOCAL CODES. 185750241 AS SHOWN M 8. AMOUNT OF REPLACED IMPERVIOUS SURFACE IS DATE: FILE PATH: N N APPROXIMATELY 2,520 SQUARE FEET. JULY 2014 V:\2123\...\Design_Drawing 0 30 60 SHEET: a 1 a w J LL SCOPE OF WORK PROPERTY INFORMATION G.C.=GENERAL CONTRACTOR SITE ADDRESS: 17127 SMOKEY PT BLVD,ARLINGTON, 0 OWNER OT =OTHERS WA 98223 999 :.:liA .i�:utt MIN.4"DEPTH HOT MIX ASPHALT 1� -----SD--- SD-- 1O G.a PERFORM BACION.THE AND BACKFILL ACE MAT SNOHOMISH COUNTY PARCEL NUMBER:31052800202200 MIN.4^DEPTH 4^s CRUSHED ——S D—————SD—— RESTORATION.THE BACKFILL MATERIAL SURFACING TOP COURSE(CSTC) SHALL BE CLASS-II AGGREGATE BASE TOWNSHIP,RANGE,SECTION:T31 R05S28 MATERIAL COMPACTED TO 90%COMPACTION. IMPORT GRAVEL BORROW TO DISPLACE LEGAL DESCRIPTION OF PROJECT SITE:SECTION 28 MIN.11.25"DEPTH 8"-2(APPROX) VOLUME OF REMOVED USTs.PLACE BACK TOWNSHIP 31 RANGE 05 QUARTER NW-N 165.04FT OF COMPACTED BACKFILL CLEAN OVERBURDEN AND COMPACT IMPORT W 180.05FT AS MEAS AT R/A TO&PLW N&W LNS OF CRUSHED SURFACING TOP COURSE(CSTC) NW 1/4 EXC N 50.01 FT THOF FOR RD ALSO EXC W 50.01FT e VIA DUMP TRUCK. FILL MATERIAL DEEPER THOF FOR RD&ALSO EXC FOR RD TH PTN LY NWLY OF THAN 12 INCHES FROM SURFACE GRADE WILL FDL BAAP ON S LN N 50.01 FT DIST 75FT ELY FIR BE COMPACTED TO 90%MAXIMUM DRY DENSITY. THE UPPER 12 CONTACT INFORMATION CROSS SECTION INCHES OF BACKFILL WILL BE COMPACTED TO PROJECT OWNER: UPPER 2 FEET UST EXCAVATION JOSE RIOS SERVICES NOT TO SCALE 20 G.a BACKFILL MATERIAL WILL BE PLACED IN 17' LIFTS AND COMPACTED TO(SITY. 90%,95%8F MELEVEN PO BOX 711 INC SERVICES 172 N D ST N E MAXIMUM DRY DEN A MINIMUM DALLAS,TX 75112 4INCHES OF(CSTC)WILL PLACE AND COMPACTED. RESURFACING JOSE.RIOS711.COMG WILL BE °� COMPLETED BY PLACING 4-INCHES OF HOT CONTACT PERSON: +yam MIX ASPHALT. PAUL FAIRBARIN •.>,•,;,;•1:• ,� \".;rK,,+;. MIN.4"DEPTH HOT MIX ASPHALT © G.c. PERFORM GRADING OF BACKFILL TO MATCH STANTEC CONSULTING SERVICES CURRENT SLOPE 11130 NE 33RD PLACE SUITE200 SITE.THE SUB-GRADE BELLEVUE,WA 98004 MIN.4-DEPTH 4"41"CRUSHED THE GROUND ON WHICH THE PARKING LOT IS SURFACING TOP COURSE(CSTC) LAID)MUST BE SMOOTH,FIRM,AND EVEN. Paul.Fairbarin Stantec.com MIN.11.25"DEPTH 8-AZ COMPACTED ———W——— CHECK GRADE BEFORE ASPHALT PAVING. 425-289-7343 work) BACKFIU- —W—— W 206-369-8383(cell) _ N —W— G.c. REPAVE EXCAVATION AREAS WITH A ENGINEER: 0 4-INCH-THICK SECTION OF ASPHALT TO MARC SAUZE,P.E. LL MATCH FEAT BOTTOM. BONDS AND SEALS WILNG LIBE MADE WITH 11130 11130STANTEC CONSULTING SERVICES BOTTOM OF UST EXCAVATION EXISTING AND NEWLY PAVED SURFACES.ALL 11130 NE 33RD PLACE SUITE Z00 o BELLEVUE,WA98004 EDGES ON THE EXISTING CONCRETE OR ASPHALT MUST BE CUT AND CLEAN BEFORE Marc.Sauze Stantec.com 425-869-944 ext 172(work) 4 VENT REPAVING OPERATIONS BEGIN. 425-894-2329(cell) LINE C- --SD--- -SD-----SD— ® G.c. STORMWATER WILL FLOW TO STORM DRAIN N CROSS SECTION UST EXCAVATION CB Lu U 70�- NOTTO SCALE O p CANOPY _ _ SIDEWALK q �� •2 z x LEGEND (785 SF) -- CB - - w 9 EXCAVATION BOUNDARY J �J\ I I CB ---- PROPERTY BOUNDARY VICINITY MAP \ I I' V ----� WATER LINE 53 K,dzle 8 K,& Q 174M g NE O \ y J \ I —ss----- SEWER LINE G] it I Nwo CB I TRASH MW_4--50— STORM LINE 172ND ST NE p DISPENSERS ' ENCLOSURE 0 MONITORINGWELL STORM CATCH BASIN(CB) Y "I Q I I UNDERGROUND STORAGE TANK(UST) —$W jp91.. ' NF Nw naa : c Ia > N N J I DEMOLITION LEGEND PREPARED BY: ii W 3 I CB C ] ASPHALT SAWCUT A z i CB111 rpl O� �� 11 2 3 Stantec 6 ti I 7-ELEVEN STORE GENERAL NOTES 11130 NE 33RD PLACE SUITE 200 •o I 0/^I..L II I I Io I I I I4 J BELLEVUE,WA98004#21341 1. CONSTRUCTION ACTIVITIES WILL BE COMPLETED IN ACCORDANCE WITH CITY OF ARLINGTON PLANNING AND PHONE:425-289-7343 FAX:42 5-869-1190 N IOIO DEVELOPMENT SERVICES REQUIREMENTS.O w I ENT ANC I I I I I 2 SAFELY,,EL MINATING THE EEDFOR MAINTENANCE AND 5 ALL HZADOUSATERIALS TOE TRANSPORTED FOR: IN I Y I I I THREAT TO PUBLIC SAFETY. 3 3. CONTRACTOR SHALL INSTALL PROTECTIVE CHAIN LINK 7-ELEVEN#21341 j N O O I FENCING OF AREA TO BE DEMOLISHED PER LOCAL I I _ / REQUIREMENTS. 17127 SMOKEY FIT BLVD TANK FIELD 4. CONTRACTOR SHALL ENSURE THAT ALL STORM DRAINS ARLINGTON,WASHINGTON AND CATCH BASINS BE PROTECTED FROM SEDMENTATION RUN-OFF.ANY ACCUMULATION OF TITLE: a I 3 (1,300 SF) Cn SEDIMENT OF OR AROUND FILTER FABRIC PROTECTION SHALL BE REMOVED IMMEDIATELY WITHOUT WATER AND DISPOSE OF ON-SITE OR REMOVED FOR DISPOSAL AT AN GRADING AND RESTORATION PLAN N I 3-12,000 GAL SINGLE OFFSITE FACILITY. UST SYSTEM REMOVAL > D WALLED STEEL USTs 5 DO NOT ALLOW VEHICLES TO TRACK SEDIMENTATION CB I INSTALLED I N 1980 6. DDEEMMOLLITION TO BE PERFORMED BY HANDWRECKING AND DRAWN BY: DESIGNED BY: H I 3 U 7. CONTRACTOR TO PERFORM ALL WORK IN ACCORDANCE BLG TO FEDERAL,STATE,AND LOCAL CODES. w 7-11 STORE SURFACE AREA TO BE I I CHECKED BY: APPROVED BY: I 8. AMOUNT OF REPLACED IMPERVIOUS SURFACE IS � SIGN APPROXIMATELY 2,520 SQUARE FEET. PF I I SAWCUT REMOVED AND PROJECT NUMBER: SCALE: a A REPLACED WITH ASPHALT 185750214 AS SHOWN NI j I (2,520 SF) C11DATE: FILE PATH: Ky 3 JULY 2014 V:\2123\...\Design_Drawing SHEET: a 0 30 60 A w J U. MINIMUM 12" SCOPE OF WORK PROPERTY INFORMATION CATCH BASIN PROTECTION OVERLAP of SEAMS G o G.G.=GENERAL OWNER CONTRACTOR = SITE ADDRESS: 17127 SMOKEY PT BLVD,ARLINGTON, OT =OTHERS WA 98223 ADAPTER RETRIEVAL O GG PLACE DEVICES E.FILTER(CB) IN INSERLET TS PROTECTION SNOHOMISH COUNTY PARCEL NUMBER:31052BOO202200 STORM DRAINS ONSITE. TOWNSHIP,RANGE,SECTION:T31 R05 S28 20 G.G PERFORM DAILY SWEEPING OF SOIL FROM LEGAL DESCRIPTION OF PROJECT SITE:SECTION 28 IMPERVIOUS SURFACE TO KEEP LARGE TOWNSHIP 31 RANGE 05 QUARTER NW-N 165.04FT OF -----SD----- AMOUNTS OF SOIL GOING INTO STORMWATER W 180.05FT AS MEAS AT R/A TO&PLW N&W LNS OF VERFLOW DO DRAINS. NW1/4 EXC N 50.01 FT THOF FOR RD ALSO EXC W 50.01FT YPASS PEAK THOF FOR RD&ALSO EXC FOR RD TH PTN LY NWLY OF GEOTEXTILETORM VOUMES) -u O G.G CONSTRUCT A SILT DIKE IF NECESSARY TO FDL BAAP ON S LN N 50.01 FT DIST 75FT ELY FIR FABRIC CONTROL STORMWATER RUN-OFF. AFTER BACKFILLING,GRADING,AND REPAVING CONTACT INFORMATION ATCH - _ _ CHECK THE WATER RUN-OFF DRAINS OFF PROJECTOWNER: ASIN - - - _ _ _ _ _ _ ASPHALT PAVEMENT TOWARDS STORM DRAINS. JOSE RIOS 50 G.G EXCAVATE AND STOCKPILE UST OVERBURDEN MANAGER ENVIRONMENTAL SERVICES SEDIMENT ACCUMULATION SOIL ON 6-MIL VISQUEEN SHEETING.COVER 7-ELEVEN INC STOCKPILE WITH VISQUEEN AS PART OF BEST PO BOX 711 IN TIES. BARRIER REQUIRED )TOE OF SLOPE MANAGEMENT PRACTICES(BMPs. DALLA ,TX 75JOSE. 112 COM 1.FILTERS SHALL BE REMOVED AND CLEANED OR REFACED AFTER EACH STORM EVENT. PLASTIC SHEETING 2.CATCH BASIN INSERTS SUITABLE FOR TRAPPING PETROLEUM HYDROCARBONS AND CONTACT PERSON: SEDIMENT WHILE ALLOWING WATER TO FILTER THROUGH(SUCH AS NORTHWEST PAUL FAIRBARIN HAZMAT CATCH BASIN INSERTS)WILL BE PLACED IN AC PAECATCH BASINS STANTEC CONSULTING SERVICES ADJACENT TO AND ON THE SITE. 172ND ST NE LEGEND 1113E NE 33RD PLACE SUITE 200 BELLEVUE,WA 98004 NOTES: Paul.Fairbarin Stantec.com SCHEMATIC OF CATCH BASIN INSERT — EXCAVATION BOUNDARY 425-2 89-7343 work) 1. PLASTIC SHEETING IS USED TO PROVIDE IMMEDIATE PROTECTION TO SLOPES AND STOCKPILES. 206-369-8383(cell) NOT TO SCALE c? 2. DO NOT USE PLASTIC COVERING UPSLOPE OF AREAS SUCH AS STEEP AND/OR UNSTABLE SLOPES THAT —""— PROPERTY BOUNDARY ENGINEER: MIGHT BE ADVERSELY AFFECTED BY CONCENTRATED RUNOFF. w WATER LINE MARC SAUZE,P.E. LL STANTEC CONSULTING SERVICES 3. WHEN POSSIBLE, INSTALL AN INTERCEPTER DIKE AT THE TOP OF THE PLASTIC TO DIVERT FLOWS AWAY 11130 NE 33RD PLACE SUITE 200 I FROM THE PLASTIC. -ss----- SEWER LINE 0 -W————W—— BELLEVUE,WA98004 Marc.Sauze@Stantec.com 4. TOE-IN THE TOP OF THE SHEETING IN A 6%6"TRENCH BACKFILLED WITH COMPACTED NATIVE MATERIAL. -----s8- STORM LINE 425-869-944 eXt 172(Work) 425-894-2329(cell) 5. INSTALL A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTION AT THE TOP OF THE SLOPE IN ORDER F STORM CATCH BASIN(CB) TO DISSIPATE RUNOFF VELOCITY. m I B. ANCHOR THE PLASTIC USING SANDBAGS OR OTHER SUITABLE TETHERED ANCHOR SYSTEM SPACED ON A C ] UNDERGROUND STORAGE TANK(UST) VENT 10' GRID SPACING IN ALL DIRECTIONS. STOCKPILE N 7. OVERLAP SEAMS 1-2',TAPE, ROLL AND STAKE THE SEAMS AND THEN WEIGH DOWN THE ENTIRE LENGTH. o I LINE C- 8. BARRIER IS REQUIRED 0 TOE OF STOCK PILE. CB LV 9. REPLACE TORN SHEETS AND REPAIR OPEN SEAMS. COMPLETELY REMOVE AND REPLACE PLASTIC WHEN IT BEGINS TO DETERIORATE. SURFACE WATER FLOW DIRECTION DURING AND AFTER RESTORATION c r, 11 P Z a CANOPY _ _ SIDEWALK � ' -Z DEMOLITION LEGEND _ - VICINITY MAP ® - � Ill C ] ASPHALT SAWCUT a (785 SF) LLI S�g Kidzle BKids Q 1]aH%NF 2 GO HL z SUPerte"�.I 5 CB � 172ND ST NE p w'V'e"�n ad lFiiii 0- GENERAL NOTES w _ 1]1it PI NE Y 1. CONSTRUCTION ACTIVITIES WILL BE COMPLETED IN N I TRASH ACCORDANCE WITH CITY OF ARLINGTON PLANNING AND w�snaP 169th St NEB 'w DEVELOPMENT SERVICES REQUIREMENTS. mPI NE DISPENSERS Ta 1 Nw cnaa,e�: , Resd, 1-dK_ N ENCLOSURE 2. ALL HAZARDOUS MATERIALS TO BE TRANSPORTED SAFELY,ELIMINATING THE NEED FOR MAINTENANCE AND PREPARED BY: N 2 3 THREAT TO PUBLIC SAFETY. c 3. CONTRACTOR SHALL INSTALL PROTECTIVE CHAIN LINK 3 FENCING OF AREA TO BE DEMOLISHED PER LOCAL REQUIREMENTS. Stantec � cog 4. CONTRACTOR SHALL ENSURE THAT ALL STORM DRAINS a I , AND CATCH BASINS - PROTECTED FROM 1113E NE 33RD PLACE SUITE 200 f° 3 CB SEDIMENTATION RUN-OFF.ANY ACCUMULATION OF H I SEDIMENT OF OR AROUND FILTER FABRIC PROTECTION BELLEVUE,WA 98004 75 ///// SHALL BE REMOVED IMMEDIATELY WITHOUT WATER AND v CB I DISPOSE OF ON-SITE OR REMOVED FOR DISPOSAL AT AN PHONE:425-289-7343 FAX:425-869-1190 0 I I 10 I I �� 10 OFFSITE FACILITY. 7-ELEVEN STORE 5. DO NOT ALLOW VEHICLES TO TRACK SEDIMENTATION FOR: cOFFSITE. TET.TEVTTa l #21341 6. DEMOLITION TO BE PERFORMED BY HANDWRECKING AND I°Q I o O I DOZER. 7-ELEVEN#21341 Wil 7. CONTRACTOR TO PERFORM ALL WORK IN ACCORDANCE 17127 SMOKEY PT BLVD W w ENTRANC I TO FEDERAL,STATE,AND LOCAL CODES. Y I I I I I ARLINGTON,WASHINGTON S'' 8. AMOUNT OF REPLACED IMPERVIOUS SURFACE IS 5 O I r^ , O APPROXIMATELY 2,520 SQUARE FEET. TITLE: CC I STORM WATER MANAGEMENT PLAN N G I TANK FIELD UST SYSTEM REMOVAL W i (1,300 SF) L W Ill 3-12,000 GAL SINGLE DRAWN BY: DESIGNED BY: co I y W LAST BLG ALLED STEEL S ` w I CHECKED BY: APPROVED BY: I INSTALLED IN 1980 30 PF o_ 3 I PROJECT NUMBER: SCALE: a I 7-11 STORE , SURFACE AREA TO BE 185750214 AS SHOWN N SIGN i DATE: FILE PATH: SAWCUT REMOVED AND JULY2014 V:\2123\...\Design_Drawing REPLACED WITH ASPHALT SHEET: a W I (2,520 SF) \ 3 LL Approved Transaction Page 1 of 1 psc lean air.org Puget Sound Clean Air Agency Notification Case #: 201402820 This page must be printed. A printout of the notification, all amendments to the notification,and the asbestos survey shall be available for inspection at all times at the asbestos project or demolition site(Reg III, 4.03(a)(6)). Fee Amount Paid $65.00 Credit Card Transaction #VXYFC1738029 Transaction Date 07/21/14 Owner's Name 7-Eleven, Inc. (owner of gas canopy to be demo'd) Phone (972)828-6592 Project Street Address 17127 Smokey Point Boulevard City Arlington Zip 98223 Contact Person Deitrie Hanson (on behalf of 7-Eleven,Inc.) Phone (425)869-9448 Mailing Address P.O. BOX 711 Dallas,TX 75221 This project includes a demolition. Demolition Start Date 10/29/14 Completion Date 11/26/14 Demolition will be completed by a demolition contractor Demo Contractor To Be Determined Contractor Job # Contact Phone Mailing Address (1) I certify that the information I have provided is to the best of my knowledge true and accurate. (2) I understand that I must file an Amendment to this Notification if: • The type of project has changed.The project types are asbestos and demolition. • The quantity of friable asbestos to be removed meets a larger project category. • The project's start or completion date has changed. (3) I understand one Notification must be filed for each structure.The only exception is for a single-family residence that includes multiple ancillary structures, such as a detached garage or other outbuildings having the same street address. If there is no street address, I have used a building number. (4) I understand the fees for this Notification are nonrefundable. Create Another Notification View History Lou Out If you have questions, contact us at asbestos@pscleanair.org or 206.689.4058. https://secure.pscleanair.org/Asbestos/Approved.aspx 7/21/2014 • DEMOLITION PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED WITH A COPY OF THE ASBESTOS/DEMOLITION NOTIFICATION FROM PUGET SOUND CLEAN AIR AGENCY, TWO (2) COPIES OF AN ASBESTOS SURVEY REPORT AND ABATEMENT REPORT (if applicable) COMPLETED BY AN APPROVED AGENCY. Type of Permit: O Residential 0 Commercial O Industrial Project Address: 17127 Smokey Pt. Blvd., Spanaway, WA 98223 Parcel ID# 310528002022 00 Subdivision: Unknown Lot #: Unknown Project Valuation: $5,000.00 No. of Buildings: 1 No. of Floors: 0 Building Area (Sq Ft): 785 Owner: 7-Eleven, Inc. Address: P.O. Box 711 City: Dallas State: TX ZIP: 75221 Contact Person: Amanda Grindle, Permit Coordinator Phone: 253-882-4546 Cell Phone: 253-882-4546 Fax Number: 253-536-5452 E-mail: agrindle@muircontracting.com Scope of Work: Remove one 785 SF steel canopy. (Remove of other gas station equipment, including tanks, piping, dispensers, etc. is covered under separate Fire Permit Application). Contractor Information Contractor: To Be Determined Phone: 000-000-0000 Address: To Be Determined License Number: To Be Determined Expiration: 12/31/2014 Please Attach Plans and Supporting Documents (PDF Only) PLANS 7-Eleven Store No. 21341 Fuel System Removal.pdf; PSCAA Notification of Demolition 7_21_2014.pdf; 21341 Arlington Asbestos Survey FINAL Report 2014.pdf STAFF USE ONLY: Permit Number: Accepted Receipt # By: Date Received: Amount Received: By submission of this form, I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington. CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address: 17127 Smokey Point Blvd Permit#:435 Parcel#:31052800202200 Valuation:5000.00 OWNER APPLICANT CONTRACTOR Name:SOUTHLAND CORP THE Name:7-Eleven,Inc. Name:Able Clean-up Technologies,Inc. Address:A-V TAX DEPT#21341 PO BOX 711 Address:P.O.Box 711 Address:4117 E Nebraska City,State Zip:DALLAS,TX 75221 City,State Zip: Dallas,TX 75221 City,State Zip:Spokane,WA 99217 Phone: Phone:253-882-4546 Phone:509-466-5255 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Demolition CODE YEAR: 2012 STORIES: I CONST.TYPE: DWELLING UNITS: 0 OCC GROUP: BUILDINGS: 0 OCC LOAD: '"l—MIMM PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSAT[ON INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC1 10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of %1* �reportedyour sales tax return fo i and coded City linton#3101. lU/6/1ID- -I Signature Print Name Date Released By Date CONDITIONS Call for final inspection. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 10/8/2014 Demolition Fee $100 00 10/8/2014 State Building Code Surcharge Fee $4 50 Total Due: $104.50 Total Payment: $104 50 Balance Due: S0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 435 Permit Date: 07/28/14 Permit Type: DEMOLITION Project Name: 7-Eleven tank removal Applicant Name: 7-Eleven, Inc. Applicant Address: P.O. Box 711 Applicant, City, State, Zip: Dallas, TX 75221 Contact: Amanda Grindle Phone: 253-882-4546 Email: agrindle@muircontracting.com Scope of Work: Tank Removal Valuation: 5000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/08/2014 Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052800202200 17127 SMOKEY POINT SOUTHLAND 541 Groceries(With BLVD CORP THE or Without Meat) Contractors Contractor Primary Contact Phone Address Contractor Type License License # Able Clean-up CONSTRUCTION Technologies,Inc. 509-466-5255 4117 E Nebraska CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 07/28/2014 Commercial Demolition No issues z.Christopher Young Fees Fee Description Notes Amount Demolition $100.00 State Surcharge- 1st DU Residential- 1st Unit $4.50 Total $l 04.50 Attached Letters Date Letter Description 07/31/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/08/2014 Amanda Grindle 52031751 cc $104.50 Outstanding Balance $0.00 Notes Date Note Created By: Receipt number 1205729 did not process the payment correctly.The payment was deleted and a 10/09/2014 new payment was processed.The new receipt number is 1205730.The payment now has Amy Rusko correctly paid the owing fees.AR 10/09/2014 The wrong date was entered,so the payment was deleted again.The correct date was entered Amy Rusko which was 10/8/2014.AR 07/29/2014 Per Deryl Taylor-Okay,as long as the store is remaining,no problem. Launa Black 07/28/2014 Sent to Marysville for review(Deryl Taylor). Launa Black Uploaded Files Date File Name 10/08/2014 808726-435-Signed Permit.pdf 07/28/2014 17127 D PSCAA Notification of Demolition 7 21 2014.12-df 07/28/2014 17127 Demolition Permit Application response.pdf 07/28/2014 17127 D 21341 Arlington Asbestos Survey FINAL Report 2014.pdf 07/28/2014 17127 D PLANS 7-Eleven Store No.21341 Fuel System Removal.pdf