Loading...
HomeMy WebLinkAbout17731 33rd Ave Ne_BLD363_2026 (3) BUILDING INSPECTION REPORT — MECHANICAL Permit No. 363 Address: 17731 33rd Ave. Contractor: CM Heating Owner: O'Hagen Date: 5/30/2014 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas HWT and Furnace Replacement GAS PIPING: N DRIP LEG: N DISCONNECT: ❑ SEISMIC: N 3" PAD: ❑ VENTING: N ECONOMIZER: ❑ COMBUSTION AIR: N MAKE-UP AIR: ❑ ACCESS: ❑ DRAIN: N DUCTS: TESTED INSULATION MATERIAL: ❑ L&I: Yes SHUT-OFF VALVE: N GUARDS: ❑ Date: 5/30/2014 INSPECTOR: YOUNG • RESIDENTIAL PLUMBING / MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING/MECHANICAL INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17731 33RD AVE NE Project Description: REPLACE GAS FURNACE AND HOT WATER TANK Owner PAT & JANE O'HAGAN Address: SAME AS ABOVE E-mail: COFFEEZGREAT@YAHOO.COM Phone (h) 360-659-3291 (c) Applicant: 1C.M. HEATING INC Address: 1415 BROADWAY, EVERETT, WA 98201 Phone (h) 425-259-6666 (c) E-mail: Contractor Information Contractor Name: C.M. HEATING INC Company: Address: 11415 BROADWAY, EVERETT, WA 98201 License Number: CMHEAI*095R4 Expiration: 05/2015 Phone: 425-259-6666 E-mail: DEBBIE@CMHEATING.COM Plumbing Section (select all that apply) Bath/Shower Combo (4.0) Sink (1 .5) Shower (2.0) Lavatory (1.0) Clothes Washer Water Closet (2.5) Dishwasher (1.5) Water Heater 1 Hose Bibb (2.5) Other (list) Proposed Water Piping Size: Proposed Piping Material: Proposed DWV Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: ® Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Please Attach Site Plan and Supporting Documents (PDF Only) R96PA SPEC SHEET.pdf Air Gas Furnaces ' 0 R96P Series The new degree of comfort- Rheem Classic Plus"' Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E.t* Input Rates from 60 to 100 kBTU [17.58 to 29.31 kW] l � tA.FU.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. `Up to 96%A.F.U.E. .1 • Up to 96% residential gas furnace CSA certified • Low profile"34 inch"cabinet ideal for space constrained • 4 way multi-poise design installations. • B • Two stages of operation to save energy and maintain optimal lower Shelf design—serviceable in all furnace orientations comfort level. Pre marked hoses—insures proper system drainage • PlusOneT" Diagnostics 7-Segment LED all units Vent with 2" or 3" PVC • PlusOneT" Ignition System—DSI for reliability and longevity Replaceable Collector box • PlusOneT"Water Management System with patented Blocked Hemmed edges on cabinet and doors Drain Sensor Quarter turn fasteners for tool less access • Heat exchanger is removable for improved serviceability. Integrated control boards feature dip switches for easy Aluminized steel primary and stainless steel secondary con- system set up struction provide maximum corrosion resistance and thermal Self priming condensate trap fatigue reliability. • Solid bottom included INTEGRATED HOME •- FORM NO.G11-539 REV.1 Air Table of Contents �i R96P Series TABLE OF CONTENTS Standard &Optional Equipment ......................................................................3 Physical Data&Specifications ........................................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 LimitedWarranty ............................................................................................9 COMFORT2 INTEGRATED HOME Air Standard&Optional Equipment a R96P Series REMOTE SENSOR DIRECT SPARK IGNITION& YJ ' REMOTE SENSOR PRIMARY AND SECONDARY aJri HEAT EXCHANGER t S • GAS VALVE AND MANIFOLD IN-SHOT BURNERS DRAFT INDUCER PRESSURE SWITCHES '� I Ill��l--`- Ili UIUIIIII)III►i� BLOCKED DRAIN ►1 N SENSOR II 1I 1 i� CONTROL 1 , 1-1]b (UMiI BOARD STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; blocked drain sensor, 7 Side and bottom filter racks; return air cabinet for all sizes. segment LED and marked hoses; heat exchanger; primary: NOTE: Furnace is not listed for use with fuels other than natural aluminized steel,secondary:29-4C stainless steel; 2 stage or L.P. (propane)gas. induced draft; pressure switches; redundant 2 stage main gas All models can be converted by a qualified distributor or local control; blower compartment door safety switch; solid state service dealer to use L.P. (propane)gas without changing burn- time on/off blower control; limit controls; manual shut-off ers. Factory approved kits must be used to convert from valve; 100% safety lock out;cool fan off delay;field selectable natural to L.P.(propane)gas and may be ordered as optional heat fan off delay;one hour automatic retry; power and self- accessories from a parts distributor. test diagnostics;flame sense current diagnostics; electronic air cleaner connections;twinning(built-in)features; humidifier For L.P. (propane)operation,refer to Conversion Kit Index Form. connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applica- tions;transformer;direct drive, multi-speed blower motor. WARNING Solid bottom. (Please note: a thermostat is not included as 1 APPROVED standard equipment.) THIS FURNACE IS 1' RECOMMENDED 1' USE IN MOBILEHOMES INTEGRATEDCOMFORT Air Physical Data&Specifications 0 R96P Series Physical Data and Specifications—Upf low Models U.S.and Canadian Models MODEL NUMBERS R96PA0602317MSA R96PA0702317MSA R96PA0852521MSA R96PA1002521MSA HIGH FIRE INPUT BTU/HR[kW] i0 56,000[16.41] 70,000[20.501 84,000[24.61] 98,000[38.711 LOW FIRE INPUT 39,200[11.49] 49,000[14.36] 58,800[17.23] 68,600[20.11] HEATING CAPACITY BTU/HR[kW] 53,760[15.751 67,200[19.681 79,800[23.391 93,100[27.281 HIGH ALTITUDE OUTPUT 48,384[14.181 60,480[17.721 71,820[21.051 83,790[24.561 10/o DERATE[kW]02 BLOWER(DxW) 11x8 11x8 11x10 11x10 [mm] [279 x 203] [279 x 2031 [279 x 254] [279 x 2541 MOTOR H.P.[W]— 1/2[373]-4-PSC 1/2[373]-4-PSC 3/4[559]-4-PSC 3/4[559]-4-PSC TYPE MOTOR FULL LOAD AMPS 6.8 6.8 8.3 8.3 HEATING SPEED—HIGH FIRE MED-HIGH MED-HIGH MED-HIGH MED-HIGH HEATING SPEED—LOW FIRE MED-LOW MED-LOW MED-LOW MED-LOW COOLING SPEED HIGH HIGH HIGH HIGH MINIMUM EXT.STATIC PRESSURE .20[.050] .23[.057] .28[.0701 .28[.070] (IN.W.C.)[kPa] MAXIMUM EXT.STATIC PRESSURE 0.8[0.19] 0.8[0.19] 0.8[0.19] 0.8[0.19] (IN.W.C.)[kPa] HEATING CFM @.2"[.049 kPa] 1139[537] 1211 [571] 1704[804] 1748[825] W.C.E.S.P.[US] COOLING CFM @.5"[.124 kPa] 1232[581] 1318[622] 1742[822] 1782[841] W.C.E.S.P.[US] TEMPERATURE RISE-HIGH FIRE 30-60 40-70 30-60 40-70 RANGE IN DEGREES°F[°C] [17-33] [22-39] [17-33] [22-39] TEMPERATURE RISE-LOW FIRE 20-50 30-60 20-50 30-60 RANGE IN DEGREES°F[°C] [11 -28] [17-33] [11 -28] [17-33] RETURN AIR CABINETS(OPT.) C17B C17B C21B C21B RXGR FILTER SIZE (2)12"x 16" (2)12"x 16" (2)12"x 20" (2)12"x 20" [mm] [305 x 406] [305 x 406] [305 x 508] [305 x 508] APPROX.SHIPPING WEIGHT 128[58] 132[60] 147.5[67] 152[69] (LBS.)[kgl AFUE O 96.00% 96.00% 95.00% 95.00% NOTES: All models are 115V,60HZ,1 phase Gas connection size for all models is 1/2"[13 mm]N.P.T. O Installation instructions for high altitude derate. •Canadian installations only. O In accordance with D.O.E.test procedures. `S=Standard Models NOTE:Standard model complies with California low nox requirements. [ ]Designates Metric Conversions 4 INTEGRATED • • •- Air Model Number Identification _0 R96P Series Model Number Identification R 96 P A — 040 2 3 17 M S A Rheem Up to Motor- Design Series Input Stage-Two Airflow Cabinet Width Configuration- S=Standard Revision- 96% PSC A=1 st Design BTU/HR 3-Up to 3 Tons 17=17.5 Multi-Position N=NOx Marketing Efficient 060=56,000[16.41 kW] 5-Up to 5 Tons 21 =21.0" (A-First Time 070=70,000[20.51 kW] 24=24.5" Release) 085=84,000[24.62 kW] 100=98,000[28.72 kW] [ ]Designates Metric Conversions INTEGRATED • COMFORT 5 Air Dimensional Data 0 R96P Series FRONT BOTTOM TOP A 121/32" 15/8' [42 mm] —I ~ I [41 mm] B B OPTIONAL I I OPTIONAL VENT OUTLET 5/16" COMBUSTION AIR 5/8" s/e" KNOCKOUT [8 mm] INLET KNOCKOUT [16 mm] [16 mm] SUPPLY AIR O 19z7/az" A 24/e" [504 mm] a [631 mm] 261/" 7 F 24" 23U3z" [667 mm] w [633 mm] R TURN 1925/32 [590 mm] [502 mm] 34" [864 mm] 9/32" [17 mm] 13/4i, 121/32' C [45 mm] [42 mm] O A 263/16"[665 mm] 253/16"[656 mm] 295/8"[752 mm] 257/16"[646 mm] 281/16"[713 mm] 235/16"[593 mm] OPTIONAL CONDENSATE OPTIONAL 11/3r-1927/32"[504 mm] 5/8" 225/1s"[567 mm] DRAIN(DOWNFLOW) CONDENSATE DRAIN [28 mm] [16 mm] (DOWNFLOW) OPTIONAL TRAP _ 2231/32" LOCATION [583 mm] (HORIZONTAL) OPTIONAL GAS CONNECTION GAS 327/8 TRAP LOCATION CONNECTION [835 mm] (HORIZONTAL) 291/1e 2313/1e OPTIONAL COMBUSTION OPTIONAL TRAP [605 mm] VENT LOCATION LOCATION 291/32" [738 mm] (HORIZONTAL) OPTIONAL CONDENSATE [738 mm] DRAIN(UPFLOW) OPTIONAL VENT 261/a" r AIR INLET 171/z" [583 mm] 177/16" f [445 mm] [443 mm] OPTIONAL LOW VOLTAGE CONDENSATE DRAIN 263/16" WIRING 14 (UPFLOW) 18161/881, [8221/332" [665 mm] [356 mm] ELECTRICAL CONNECTION [ 4 PTIONAL LINE VOLTAGE LINE VOLTAGE WIRING ELECTRICAL CONNECTION L LOW VOLTAGE J 1 1 —4 L 225/8"[575 mm] 1. 23"[584 mm] 1.1243/16"[614 mm] 8" 111/32" 11" 8" 265/16"[668 mm, [203 mm] [280 mm] [279 mm] [203 mm] RIGHT SIDE LEFT SIDE UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) MINIMUM CLEARANCE(IN.)[mm] FLANGE DIMENSIONS MODEL LEFT RIGHT SHIP R96P SIDE SIDE BACK TOP FRONT VENT WGTS. A B C 060 0 0 0 1 [25] 2[51] 0 128 [58] 171/2[445] 1617/64[413] 1613/64[412] 070 0 0 0 1 [25] 2[51] 0 132 [60] 171/2[445] 1617/64[413] 1613/64[412] 085 0 0 0 1 [25] 2[51] 0 147.5[67] 21 [533] 1949/64[502] 1945/64[500] 100 0 0 0 1 [25] 1 2[51] 0 j 152 [69] 21 [533] 1949/64[502] 1 1945/64[500] *A service clearance of at least 24"is recommended in front of all furnaces [ ]Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. Air Blower Performance Data 0 R96P Series BLOWER MOTOR BLOWER CFM [L/s]AIR DELIVERY MODEL SIZE H.P. SPEED EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPal [mm] [W] 0.1 [.02] 0.2[.05] 0.3[.07] 0.4[.101 0.5[.12] 0.6[.151 0.7[.17] 0.8[.191 LOW 830 [392] 793[374] 755[356] 705[333] 654[308] 599[283] 544[257] 496[234] R96PA 11 x 8 112 MED-LO 940 [443] 908[428] 875[413] 821 [387] 766[361] 710[333] 653[308] 584[275] 0601317 [279 x 203] [373] MED-HI* 1168 [551] 1139[537] 1109[523] 1060[500] 1010[476] 942[444] 874[412] 802[378] HIGH 1421 [670] 1 1385[653 1 1349[636] 1291 [609] 1232[581] 1 1147[541 1 1062[501] 1 976[460] LOW 852 [402] 827[390] 802[378] 752[355] 701 [331] 662[312] 623[294] 580[274] R96PA 11 x 8 1/2 MED-LO 986 [465] 955[450] 923[435] 883[417] 843[398] 790[373] 737[348] 686[324] 0701317 [279 x 203] [373] MED-HI* 1238 [584] 1211 [571] 1183[558] 1139[537] 1094[516] 1036[489] 978[461] 897[423] HIGH 1493 [704] 1452[685] 1410[665] 1364[643] 1318[622] 1257[593] 1195[564] 1084[511] LOW 1313 [619] 1275[601] 1236[583] 1221 [576] 1184[558] 1141 [538] 1098[518] 1053[497] R96PA 11 x 10 3/4 MED-LO 1488 [702] 1452[685] 1415[667] 1384[653] 1328[626] 1279[603] 1229[580] 1170[552] 0852521 [279 x 254] [559] MED-HI* 1732 [817] 1704[804] 1676[791] 1630[769] 1579[745] 1498[707] 1417[668] 1343[633] HIGH 1983 [935] 1929[910] 1874[884] 1810[854] 1742[822] 1663[784] 1583[747] 1477[697] LOW 1329 [627] 1313[619] 12966111 1260[594] 1224[577] 1171 [552] 1117[527] 1049[495] R96PA 11 x 10 3/4 MED-1-0 1535 [724] 1498[707] 1461 [689] 1422[671] 1382[652] 1325[625] 1268[598] 1203[567] 1001521 [279 x 254] [559] MED-HI* 1796 [847] 1748[825] 1700[802] 1656[781] 1612[760] 1536[725] 1460[689] 1370[646] HIGH 2O19 [952] 1961 [925] 1903[898] 1843[869] 1782[841] 1687[796] 1592[751] 1489[702] *Factory setting for heat all grey cells are valid heating settings.Do not use speed tabs and/or static pressure which do not fall into the grey cells on this table. NOTE:Unit tested without filters. [ ]Designates Metric Conversions. INTEGRATED • COMFORT 7 Air Accessories -a R96P Series VENT TERMINATION KITS: = FOR HIGH ALTITUDES: RXGY-E02:Vertical/Horizontal Concentric Vent Termination Kit NOTE:For Canadian installations only,an optional Berate(manifold 2" Pipe(US Only) gas pressure reduction)method may be used to adjust the furnace for altitude.See Installation Instructions for more RXGY-E02A:Vertical/Horizontal Concentric Vent Termination Kit information.This optional method may NOT be used for U.S. 2" Pipe(US&Canadian) installations.See installation instructions as appropriate orifice RXGY-E03:Vertical/Horizontal Concentric Vent Termination Kit change is required. 3" Pipe(US Only) RXGY-E03A:Vertical/Horizontal Concentric Vent Termination Kit L.P.CONVERSION KIT:RXGJ-FP34 3" Pipe(US&Canadian) RETURN AIR PLENUM KIT.RXGR-C1713 RXGR-C21B RXGY-G02:Direct Vent Furnace Side Wall Vent 2"or 3" (US Only) RXGR-C24B RXGY-D05:Combustion Air Drain Kit 2" CONDENSATE PUMP KIT. PROSTOCK&1 PC13151TUL RXGY-D06:Combustion Air Drain Kit 3" DOWNFLOW/HORIZONTAL CONVERSION KIT.RXGY-CK NEUTRALIZER KIT. RXGY-A01 DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE (Replacement Cartridge 54-22120-01) CONVERSION KIT. RXGY-ZK FOSSIL FUEL KIT: RXPF-F01,RXPF-F02(TVA) COMBUSTIBLE FLOOR BASE:RXGC-1317 RETURN AIR PLENUM:RXGR-C176 RXGC-1321 RXGR-C21B RXGC-624 RXGR-C24B EXTERNAL BOTTOM FILTER(UPFLOW/HORIZONTAL)RACK: [ ]Designates Metric Conversions RXGF-CB EXTERNAL SIDE(UPFLOW)FILTER RACK:RXGF-CD EXTERNAL(DOWNFLOW)FILTER RACK: RXGF-CC FILTER RACK FILTER SIZES*INCHES[mm] RXGF-CB RXGF-CD RXGF-CC MODEL (UPFLOW/ (UPFLOW) (DOWNFLOW) HORIZONTAL) R96PA060 153/4 x 25 153/4 x 25 12 x 20 [400 x 6351 [400 x 6351 [305 x 5081 R96PA070 153/4 x 25 153/4 x 25 12 x 20 [400 x 6351 [400 x 6351 [305 x 5081 R96PA085 191/4 x 25 153/4 x 25 12 x 20 [489 x 635] [400 x 635] [305 x 508] R96PA100 191/4 x 25 153/4 x 25 12 x 20 [489 x 635] [400 x 635] 1 [305 x 508] *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1"[25.4 mm]filter. INDOOR COIL CASINGS MODEL NUMBER RXBC-D17A1 RXBC-D21A1 RXBC-D21B1 RXBC-D24A1 8 INTEGRATED HOME •- Air Limited Warranty D R96P Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten (10)Years period stated, in accordance with the terms of the limited Heat Exchanger.........................................Limited Lifetime warranty. *For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. ---'a INTEGRATED • COMFORT 9 Air Notes a R96P Series 10 INTEGRATED • • •- Air Notes D R96P Series INTEGRATED • • •- The new degree of comfort.' In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • P.O.Box 17010 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72917 • www.rheem.com Brampton,Ontario • L6Y OP5 0 INTEGRATED HOME COMFORT PRINTED IN U.S.A 12/13 QG FORM NO.G11-539 REV.1 CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17731 33RD AVE NE Permit#:363 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00621300006700 DATE OF ISSUANCE. Scope of Work:Replace Gas Furnace and Water Heater Valuation: .00 OWNER APPLICANT CONTRACTOR OHAGEN P J C.M.Heating Inc C.M.HEATING INC 17731 33RD AVE NE 1415 Broadway 1415 BROADWAY ARLINGTON,WA 98223-8739 Everett,WA 98201 EVERETT,WA 98201 425-259-6666 425-259-6666 LIC:CMHEAI*095R4 EXP:05/03/2015 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR C.M.HEATING INC 1415 BROADWAY EVERETT,WA 98201 425-259-6666 LIC#:CMHEAI*095R4 EXP: 5/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL CODE YEAR: MECHANICAL/PLUMBING STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 05/06/2014 Applicant Signature Date Building Official Date CONDITIONS Furnace and water heater to be installed per specifications.Duct testing of existing ducts will need to be completed. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/11/2026 Mechanical Fee(Enter Fixture Fee) $25.00 09/11/2026 Mechanical Base $25.00 09/11/2026 Plumbing Base $25.00 09/11/2026 Water Heater(Tank) $25.00 Total Due: $100.00 Total Payment: $100.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Date: 09/11/2026 Permit#: 363 Permit Date: 05/06/2014 Review Date: 05/06/2014 Permit Type: RESIDENTIAL MECHANICAL/PLUMBING Review Type: RESIDENTIAL MECHANICAL Target Date: 05/07/2014 Scheduled Time: Completed 05/06/2014 Date: Description: Replacement gas furnace is 96%AFUE and water heater will need to be .58 or better. Duct testing of existing ducts will need to be completed. Review Status: Assigned To: Time In: Time Out: Hours: Property Information Parcel#: 00621300006700 OHAGEN P J OHAGEN P J 17731 33RD AVE NE 17731 33RD AVE NE ARLINGTON, WA 98223-8739 Zoning: 111 Single Family Residence - DetachedLot: Block: Permit#: 363 Permit Date: 05/06/14 Permit Type: RESIDENTIAL MECHANICAL/PLUMBING Project Name: Pat& Jane O'Hagen Applicant Name: C.M. Heating Inc Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett, WA 98201 Contact: Phone: 425-259-6666 Email: debbie@cmheating.com Scope of Work: Replace Gas Furnace and Water Heater Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/06/2014 Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300006700 17731 33RD AVE NE OHAGEN P J 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# C.M.HEATING INC 425-259-6666 1415 BROADWAY CONSTRUCTION CMHEAI*095R4 CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 05/06/2014 RESIDENTIAL Replacement gas furnace is 96%AFUE and water heater MECHANICAL will need to be.58 or better.Duct testing of existing ducts will need to be completed. Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Plumbing Base Permit Fee $25.00 Water Heater(Tank) $25.00 Total $100.00 Attached Letters Date Letter Description 05/06/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/06/2014 C.M.HEATING INC 50189895 cc $100.00 DEBBIE BAUERS Outstanding Balance $0.00 Uploaded Files Date File Name 05/30/2014 17731 33rd Ave..docx 05/06/2014 LLD 363 Application.pdf 05/06/2014 BLD 363 Spec Sheet.pdf