Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19405 68th Dr Ne_BLD342_2026
COMMERCIAL REMODEL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403 3551 THIS APPLICATION MUST BE ACCOMPANIED BY THREE(3) SETS OF CONSTRUCTION PLANS, THREE(3) SETS OF SPECIFICATIONS, TWO(2) SETS OF STRUCTURAL CALCULATIONS, ONE(1) SETS OF NREC ENERGY CODE APPLICATIONS AND ONE(1) OCCUPANTS'S STATEMENT OF INTENDED USE. Type of Permit: ( ) Commercial Remodel ( ) Commercial Addition ( Tenant Improvement Project Address: c s e, T� PnV4 Iy Parcel ID#: Project Description QNMI i ay JA ALL POO 0- Legal Description Project Valuation: ®© ' �✓ Owner: Phone Number: Z 70 Address: 14 SOUIAJ City: Se— 4 0t U"v State: 0 Zip Code: Contact Person: Ra I&flr lxl '1 Phone Number: 4 ZT -116`1 Cell Phone: �Z�' �(+�y ' 3'�q Fax: �#�S" .22-Co I 9 E-mail: libll 0 W06fC0JJJTr'UCVWJ 106-COM Address: ��Q �CIC �` City: J;IllM1 GI 4ki State: Zip Code: 4T&V4 Contractor: 00061c PIT2 MOPJ Phone Number: Z1 727 'SO Address: Ra ftr, City: State: Zip Code: J,902y Contractor's License Number: `D 2 Expiration. r Z' Plumbing Contractor: 01A Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration Mechanical Contractor: ti A Phone Number: Address City: State: Zip Code: Contractor's License Number: Expiration: I hereby c ify that the above information is correct and that the construction on, and the occupancy and the use of the above- des( pr perty will be in accordance with the laws, rules and regulation of th State of ashington. ., f=/ y 18], Applicants S�nat re Date fn �,l t- Print Applicants Name FOR STAFF USE ONLY AV 5 0-1- c&— 4&_ Permit# Accepted By Amount Received Receipt# Date Received Page 6 of 7 -- COMMERCIAL REMODEL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403 3551 Project Name/Tenant L)/' Site Address [ 9406' 68' JX19f l)C Bldg/Unit/Suite IBC Construction Type IBC Occupancy Type Description of Use fCe LU i bysie Building Square Footage Number of Stories 2- Square Footage Per Floor Will there be any installation, modification or removal of the following? (Check all that apply) ❑ Automatic fire extinguishing systems ` ❑ Compressed gas systems ❑ Fire alarm and detection systems ❑ Fire pumps ❑ Flammable and combustible liquids(tanks, piping etc...) ❑ Hazardous materials ❑ High piled/rack storage ❑ Industrial ovens/furnace ❑ Private fire hydrants ❑ Spraying or dipping operations ❑ Standpipe systems ❑ Temporary membrane structure,tents(>200sq ft)or canopies (>400 sq ft) Provide details on any of the above checked items: Installation,changes,modifications or removal of any of the above may require additional submittals, information, or permits during the plan review or construction process. Printed Pgre of Occupant/Agent - -rq Sig ature kf Occupant/Agent Date Page 7 of 7 d n 0 v o o fD O N ro + n 3 = m p A G v�i W N O' O H ; G W O CL 3 O _ m a O O n D -' m IJ ► 0 3 m z�c a m I r n m S m C n v o f a o I - N f f c m w O m i v (D CL o w O a 7 C CL'O - 0 I � � � � CL o O- N S .� N 1 ° O A i 1 O 1• o m s � D I rt O I O 7 3 I cm r i 0 O M O ►o i �; 3 fu i N � CL 0 m .a fu 7 H O_ fD m Q. � r V m •G C. O O rt n r d C_ N 0 0 3 N O f+ A 0 O ' 33 m y h m eo �° °' o v m 3 > > - = ro IO lu ---—--—--—--—--—--—--—- o v f $A v ': ro I m tooSLT o C - rtm =V IS I SRO ' QFa E � ( \ o 'm a o " ; a X° > c o I a 0 a o 0i 0 m rt m _ - m J a 3 i m �p O 3 • ,� n (AO ao 3 O I � 3; A r i UQ 0 O c _ m a O 0 � i i I O I O C. m d � r < y Q. O O n r GI C. vi O O 3 I w W I 0 A I SECTION 081113 STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Provide wooden doors and frames: 1. Interior wooden doors and frames. 1.2 SUBMITTALS A. Product Data: Submit manufacturer's product data and installation instructions for each material and product used. 1.3 QUALITY ASSURANCE A. Comply with governing codes and regulations. Provide products of acceptable manufacturers which have been in satisfactory use in similar service for three years. Use experienced installers. Deliver, handle, and store materials in accordance with manufacturer's instructions. B. Standards: ANSIA250.8/SDI-100, Recommended Specifications for Standard Steel Doors and Frames. C. Performance Standards: 1. Fire-Rated Assemblies: NFPA 80, and acceptable testing agency listing. 2. Thermal-Rated Assemblies at Exterior: ASTM C 236. 3. Door rating to be attached to door and frame. 1.4 SUSTAINABLE DESIGN REQUIREMENTS A. USGBC LEED Certification: Comply with Section 011050 - LEED Requirements, Section 013350 -LEED Submittals. PART2-PRODUCTS 2.1 MATERIALS A. Acceptable Manufacturers: Amweld Building Products, Ceco Door Products, Curries Co., or Steelcraft Manufacturing. B. Steel Frames: 1. Interior Frames: a. Material: Sheet steel. b. Type: Knockdown. c. Thickness: 16 gage (.0598 inch). d. Corners: Mitered or coped. December 26, 2013 081113-1 Arlington LOE Room 2. Accessories: a. Door silencers b. Plaster guards. 3. Finish: Factory primed and field painted. PART 3-EXECUTION 3.1 INSTALLATION A. Fabricate work to be rigid, neat and free from seams, defects, dents, warp, buckle, and exposed fasteners. Install doors and frames in compliance with SDI-100,NFPA 80, ANSVICC A117.1 and requirements of authorities having jurisdiction. B. Provide thermally improved doors with maximum U-value of 0.24 BTU/hr./sq. ft. degree F (ASTM C 236) for all exterior doors and elsewhere as noted. C. Hardware: Prepare doors and frames to receive hardware on final schedule. Provide for 3 silencers on single door frames; 2 on double door frames. D. Shop Finish: Clean,treat and prime paint all work with rust-inhibiting primer comparable with finish paint specified in Division 9 section. Provide asphalt emulsion sound deadening coating on concealed frame interiors. E. Touch-up damaged coatings and leave ready to receive finish painting. End of Section Arlington LOE Room 081113-2 December 26,2013 SECTION 087100 DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. Provide the following: 1. Interior and exterior door hardware. 1.2 SUBMITTALS A. Product Data: Submit manufacturer's product data and installation instructions for each material and product used. B. Samples: Submit two representative samples of each material specified indicating visual characteristics and finish. Include range samples if variation of finish is anticipated. C. Schedule: Submit for approval hardware schedule proposed for use based on Owner's requirements and specified requirements D. Operation and Maintenance Data: Submit manufacturers' operation and maintenance data, including list of spare parts and special tools. Provide one full set of maintenance tools. 1.3 QUALITY ASSURANCE A. Comply with governing codes and regulations. Provide products of acceptable manufacturers which have been in satisfactory use in similar service for three years. Use experienced installers. Deliver, handle, and store materials in accordance with manufacturer's instructions. B. Hardware for Fire-Rated Openings: NFPA 80, and local requirements. C. Materials and Application: ANSI/BHMA A156 series standards. 1.4 SUSTAINABLE DESIGN REQUIREMENTS A. USGBC LEED Certification: Comply with Section 011050 -LEED Requirements, Section 013350 -LEED Submittals. 1.5 MAINTENANCE/OPERATION A. Deliver 2 construction core keys to Project Engineer prior to securing building. B. Deliver to Project Engineer, a complete set of specialized tools as needed for Owner's continued adjustment, maintenance, and removal and replacement of hardware. December 26, 2013 087100-1 Arlington LOE Room PART2-PRODUCTS 2.1 HARDWARE A. Provide items as listed in Hardware Sets at end of this Section, complete to function as intended. B. Provide hardware for fire rated doors in compliance with NFPA 80, which has been UL listed and labeled with applicable fire rating. 2.2 HINGES A. Acceptable Manufacturers: Hager Companies, Lawrence Brothers, Inc., Assa Abloy McKinney Products, and Stanley Hardware Div. of The Stanley Works. B. Provide template produced hinges complying with ANSIBHMA A156.1. C. Pins: Steel for steel hinges and stainless steel for non-ferrous hinges; non-removable pins for exterior doors and non-rising pins for interior doors. D. Tips: Flat button and matching plug, finished to match leaves. E. Material and Finish: Satin stainless steel [satin chromium plated ANSI A156.18; Finish Code 630 or 626]. F. Hinges Per Door: 3 hinges for doors 90 inches or less in height and one additional hinge for each 30 inches of additional height. G. Butt Hinges: Full mortised, 4-1/2 inches x 4-1/2 inches; standard weight ball bearing or plain bearing as indicated in hardware schedule. 2.3 LOCKS AND LOCK TRIM A. Acceptable Manufacturers: Best Access Systems, Corbin/Russwin Architectural Hardware, Yale/Locks and Hardware, and Sargent Manufacturing Co., Insta-Key. B. Provide bored (cylindrical) locks and lever handled lock trim complying with ANSI A 156.2. C. Provide mortise locks and lever handled lock trim complying with ANSI A156.13. D. Equip mortise locks with cylinders to receive "Fig. 8" interchangeable, 6 pin tumbler cores by Best. E. Equip keyed bored (cylindrical) locks with lever handles to receive "Fig. 8" interchangeable, 6 pin tumbler cores by Best. F. Furnish keyed locks with removable "Fig. 8" construction cores and keys by Best. G. Lock Cylinders: One piece design, machined from extruded brass or bronze rod; symmetrical lugging with angular set screw grooves; concealed set screw for securing cylinder to lockset, accessible only with core removal; satin stainless steel H. Strikes: Curved lip extended to protect frame; with wrought box. I. Provide and install construction cores on all doors with mortise or bored lock sets. Arlington LOE Room 087100-2 December 26, 2013 2.4 FLUSH BOLTS A. Acceptable Manufacturers: Builders Brass Works Corp., H.B. Ives. Div of Harrow Corp., and S. Parker Hardware Mfg. Corp. B. Provide lever extension flush bolts complying with ANSI A156.16, and designed such that bolt head is projected or withdrawn manually by finger operation of lever. C. Bolt Head: Minimum 1/2 inch diameter rod, 12 inches long. D. Material and Finish: satin stainless steel satin chromium plated(ANSI A156.18; Finish Code 630 or 626). E. Flush Bolts Per Door: 2, one at top and one at bottom. 2.5 EXIT DEVICES A. Acceptable Manufacturers: Corbin/Russwin Architectural Hardware, Precision Hardware Inc., and Sargent Manufacturing Co. B. Material and Finish: Satin stainless steel, Code 630. 2.6 DOOR CLOSERS A. Acceptable Manufacturers: LCN Division of Ingersoll-Rand Architectural Hardware, Sargent Manufacturing Co., and Yale Locks and Hardware. B. Provide door closers complying with ANSI A156.4 modern type, Grade 1 with full plastic cover, adjustable spring power at least 50 percent over minimum value, adjustable hydraulic backcheck, delayed action device, and separate valves for control of latch and sweep speeds, so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in from the latch, measured from the leading edge of the door. C. Provide integral cushioned stop with closer arms specified for exterior standard steel doors. D. Mounting: Surface mounted, parallel arm unless otherwise indicated. E. Size closer units in compliance with manufacturer's recommendations for maximum door width for interior or exterior doors, as applicable. Size parallel arm units one size larger than recommended for use with standard arms. F. Material and Finish: Satin stainless steel (ANSI A156.18; Finish Code 630); matching color on plastic closer cover.. 2.7 DOOR STOPS A. Acceptable Manufacturers: H.B. Ives, Builders Brass Works Corp., Rockwood Manufacturing Co., and S. Parker Hardware Mfg. Corp. B. Door Stops: Floor mounted units of cast stainless steel with rubber bumper surface. 2.8 FASTENERS A. Furnish Phillips flat-head screws for installation, with each hardware item. December 26, 2013 087100-3 Arlington LOE Room 2.9 LATCH SHIELD A. Manufacturers: Latch-Guard Inc. B. Furnish steel latch shield with flush mounted joint connector nut type fastener. PART 3 -EXECUTION 3.1 INSTALLATION A. Follow guidelines of DHI "Recommended Locations for Builder's Hardware and hardware manufacturers' instructions. B. Install materials and systems in accordance with manufacturer's instructions and approved submittals. Install materials and systems in proper relation with adjacent construction and with uniform appearance. Coordinate with work of other sections. C. Adjust operation, clean and protect. 3.2 HARDWARE SETS A. HS-1 (Exterior Standard Hollow Metal). 1. Butt Hinges -ball bearing. 2. Exit Device. 3. Door Closer. 4. Door Stop. 5. Brush Seal. 6. Latch shield. 7. Kick Guard End Of Section Arlington LOE Room 087100-4 December 26, 2013 B. Install gypsum board assemblies in compliance with ASTM C 840 and GA 216, Specifications for the Application and Finishing of Gypsum Board. Install gypsum board assemblies true, plumb, level and in proper relation to adjacent surfaces. C. Install boards vertically. Do not allow butt-to-butt joints and joints that do not fall over framing members. D. Where new partitions meet existing construction, remove existing cornerbeads to provide a smooth transition. E. Provide insulation full height and thickness. F. Provide acoustical sealant at both faces at top and bottom runner tracks, wall perimeters, openings, expansion and control joints. G. Install trim and 3-coat joint treatment in strict compliance with manufacturer's instructions and recommendations. Joint treatment is required at all fasteners and edges between boards. Fill all surface defects. Sand between and after joint treatment coatings and leave ready for finish painting. End Of Section December 26, 2013 092116-3 Arlington LOE Room CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 19405 68TH DRIVE NE Permit#:342 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31051400302400 DATE OF ISSUANCE. Scope of Work:Demising wall Valuation: 3700.00 OWNER APPLICANT CONTRACTOR ARLINGTON INVESTORS LLC Hodge Construction Hodge Construction 1809 7TH AVE STE 1002 PO Box 1105 PO Box 1105 SEATTLE,WA 98101 Fall City,WA 98024 Fall City,WA 98024 425-864-3669 425-864-3669 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL ALTERATION CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 04/07/2014 Applicant Signature Date Building Official Date CONDITIONS The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/10/2026 Building Permit $126.82 09/10/2026 State Surcharge-list DU $4.50 09/10/2026 Building Plan Review $82.43 Total Due: $213.75 Total Payment: $213.75 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail C09.FRAMING I Approved Permit#: 342 Permit Date: 04/04/14 Permit Type: COMMERCIAL ALTERATION Project Name: UPS Applicant Name: Hodge Construction Applicant Address: PO Box 1105 Applicant, City, State, Zip: Fall City,WA 98024 Contact: Robert Will Phone: 425-864-3669 Email: bob@hodgeconstructioninc.com Scope of Work: Demising wall Valuation: 3700.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/23/2014 Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 399 Other 31051400302400 19405 68TH DRIVE NE INVESTORS LLC Miscellaneous Manufacturing NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License # Hodge Construction Robert Will 425-864-3669 PO Box 1105 CONSTRUCTION CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 04/24/2014 C09.FRAMING Wall for server room 04/24/2014 04/24/2014 z.Christopher Young Approved Plan Reviews Date Review Type Description Assigned To Review Status 04/04/2014 COMMERCIAL Ok to issue permit z.Christopher Young ALTERATION Fees Fee Description Notes Amount Building Permit Table 4-1 $126.82 State Surcharge- 1 st DU Residential- 1 st Unit $4.50 Building Plan Review Table 4-2 $82.43 Total $213.75 Attached Letters Date Letter Description 04/07/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/23/2014 Robert Will 50021555 cc $213.75 Outstanding Balance $0.00 Uploaded Files Date File Name 04/04/2014 LLD 342 Application.pdf 04/04/2014 BLD 342 Specs.pdf