HomeMy WebLinkAbout19406 45th Dr Ne_BLD288_2026 (3) BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 288 Address: 19406 45th Dr. NE Contractor: Brennan Heating Owner: Garcia Date: 2/24/2014 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Furnace Replacement FURNACE: M HEAT PUMP/AC UNIT: GAS PIPING: © DISCONNECT: ❑ DRIP LEG: ® SEISMIC: ❑ VENTING: ® 3" PAD: ❑ ACCESS: ® INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: Fx DUCTS: TESTED L&I: Yes Date: 2/24/2014 Inspector: Young RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:A41(kr. r Project Description: c 1 �� . - ICE Owner: Pn n ; (- � OU Address: , !a Phone: qa Email:_ Applicant: Brennan Heating Address:4601 S 134th PI Seattle 98168 Phone: 206-248-7900' Email: Jaimie@brennanheating.com Applicant Signatur 7_ Electronic Signature if submitting on-line I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29 Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit#: Accepted by _ Date: Received FEB 11 2014 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank ❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Ur Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances:��, 00D • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances 0 A shut-off valve is required within 6 feet of all appliances SPECIFICATIONS Gas Model No. SL280UH07OV36A SL280UH09OV36B SL280UH09OV48B Heating Model No.-Low Nox SL280UH07OXV36A --- SL280UH09OXV48B Performance 'AFUE 80% 80% 80% High Input-Btuh 66,000 88,000 88,000 Fire Output-Btuh 52,000 70,000 70.000 Temperature rise range-°F 40-70 40-70 40-70 Gas Manifold Pressure(in.w.g.) 3.5110 3.5/10 3.5/10 ' Nat.Gas/LPG/Propane Low Input-Btuh 43,000 57,000 57,000 Fire Output-Btuh 35,000 47,000 47,000 Temperature rise range-°F 25-55 25-55 25-55 Gas Manifold Pressure(in.w.g.) 1.7/4,9 1,7/4.9 1,714,9 Nat. Gas/LPG/Propane High static-in.w.g. Heating 0.8 0.8 0.8 Cooling 1.0 1.0 10 Connections Flue connection -in. round 4 4 4 in. Gas pipe size IPS 1/2 1/2 112 Indoor Wheel nominal diameter x width-in. 10 X 8 10 X g 11-112 X 9 Blower Motor output-hp 1/2 1/2 1.0 Tons of add-on cooling 2-3 2-3.5 2.5-4 _ Air Volume Range-cfm 606-1345 498- 1393 1 679-2002 Electrical Data Voltage 120 volts-60 hertz-1 phase Blower motor full load amps 7.7 7 7 12.8 Maximum overcurrent protection 15 15 _ 20 Shipping Data lbs.-1 package 128 143 _ I 154 NOTE-Filters and provisions for mounting are not furnished and must be field provided Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces Flue connection on the unit is 4 in,diameter.Most applications will require 5 in.venting and field supplied 4 x 5 in.adaptor.See Venting Tables in the Installation Instructions for detailed information SPECIFICATIONS Gas Model No. SL280UH09OV60C SL280UH11OV60C SL280UH135V60D Heating Model No.-Low Nox SL280UH09OXVGOC SL280UH11 OXVGOC --- Performance 'AFUE 80% 80% 80% High Input-Btuh 88.000 110,000 132.000 Fire Output-Btuh 70,000 87.000 105,000 Temperature rise range-°F 35-65 1 35-65 40-70 Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5/10.0 Nat. Gas/LPG/Propane Low Input-Btuh 57,000 72,0120 86.000 Fire Output-Btuh 47.000 58,OCO 69,000 Temperature rise range-°F 25-55 25-55 25-55 Gas Manifold Pressure(in,w.g.) 1.7/4.9 1.7/4.9 1.7/4.9 _ Nat. Gas/LPG/Propane High static-in.w.g. Heating 0.8 0.8 0.8 Cooling 1.0 1.0 1.0 Connections Flue connection -in. round 4 4 3 4 in. Gas pipe size IPS 1/2 1/2 1/2 Indoor Wheel nominal diameter x width-in. 11-1/2 X 10 11-1/2 X 10 11-112 X 11 Blower Motor output-hp 1.0 1.0 1.0 Tons of add-on cooling 3-5 3-5 3.5-5 Air Volume Range-cfm 826-2305 812-2125 828-2257 Electrical Data Voltage 120 volts-60 hertz-1 phase Blower motor full load amps 12.8 12.8 12.8 Maximum overcurrent protection 20 20 20 Shipping Data lbs.- 1 package! 173 181 199 NOTE-Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE lest procedures and according to FTC labeling regulatons Isolated combustion system rating for non-weatherized furnaces Flue connection on the unit is 4 in.diameter.Most applications will require 5 in venting and field supplied 4 x 5 in adaptor.See Venting Tables in the Installation Instructions for detailed information SL280UHV/Page 9 CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 19406 45TH DR NE Permit#:288 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00928200006400 DATE OF ISSUANCE. Scope of Work:Replace gas furnace Valuation: .00 OWNER APPLICANT CONTRACTOR GARCIA RONALD H&DEENA L Brennan Heating Brennan Heating 19406 45TH DR NE 4601 S 134th Place 4601 S 134TH PL ARLINGTON,WA 98223-4758 Seattle,WA 98168 TUKWILA,WA 98168 206-248-7900 206-248-7900 LIC:602 346 866 EXP: 12/31/2026 LIC:BRENNHA97IR9 EXP: 12/29/2027 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Brennan Heating 4601 S 134th Place Seattle,WA 98168 206-248-7900 LIC#:BRENNHA971R9 EXP: 12/29/2015 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2012 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. i/ 02/11/2014 Applicant Signature Date Building Official Date CONDITIONS The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/08/2026 Mechanical Fee(Enter Fixture Fee) $25.00 09/08/2026 Mechanical Base $25.00 Total Due: $50.00 Total Payment: $50.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 288 Permit Date: 02/11/14 Permit Type: RESIDENTIAL MECHANICAL Project Name: Garcia Applicant Name: Brennan Heating Applicant Address: 4601 S 134th Place Applicant, City, State, Zip: Seattle,WA 98168 Contact: Jaimie How Phone: 206-248-7900 Email: Jaimie@brennanheating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 02/12/2014 Permit Expires: Permit Form Type: Civic Plus Number: Status: COMPLETE Assigned To: Launa Black Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00928200006400 19406 45TH DR NE GARCIA RONALD 111 Single Family H&DEENA L Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor d BRENNHA971R9 CONTRACTOR Industri anes Fees Fee Description Notes Amount Mechanical Fee(Enter Fixture Fee) $25.00 Mechanical Base Permit Fee $25.00 Total $50.00 Attached Letters Date Letter Description 02/11/2014 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 02/11/2014 Jaimie How 49175702 cc $50.00 Outstanding Balance $0.00 Uploaded Files Date File Name 02/24/2014 19406 45th Dr.docx 02/11/2014 BLD-288.pdf