HomeMy WebLinkAbout19430 45th Dr Ne_BLD270_2026 (3) CITY OF ARLINGTON
` 18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551
BUILDING PERMIT
19430 45TH DR NE Permit#:270
PERMIT EXPIRES 180 DAYS AFTER
Parcel#: 0093 0600003 100 DATE OF ISSUANCE.
Scope of Work:Replace gas furnace&install new heat pump Valuation: 5200.00
OWNER APPLICANT CONTRACTOR
SCHWANS FREDERICK Brennan Heating Brennan Heating
19430 45TH DR NE 4601 S 134th Place 4601 S 134TH PL
ARLINGTON,WA 98223 Seattle,WA 98168 TUKWILA,WA 98168
206-248-7900 206-248-7900
LIC:602 346 866 EXP: 12/31/2026
LIC:BRENNHA97IR9 EXP: 12/29/2027
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Brennan Heating
4601 S 134th Place
Seattle,WA 98168
206-248-7900
LIC#:BRENNHA971R9 EXP: 12/29/2015 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2012
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
i/ 12/30/2013
Applicant Signature Date Building Official Date
CONDITIONS
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The
property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment
or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant
authorities before commencing construction.The property owner shall ensure that the construction project complies with all
applicable design review requirements.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
09/08/2026 Mechanical Fee(Enter Fixture Fee) $50.00
09/08/2026 Mechanical Base $25.00
Total Due: $75.00
Total Payment: $75.00
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
INSPECTION INFORMATION Pass/Fail
C 10.MECHANICAL ROUGH-IN Approved
Permit#: 270
Permit Date: 12/26/13
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Schwans
Applicant Name: Brennan Heating
Applicant Address: 4601 S 134th Place
Applicant, City, State, Zip: Seattle,WA 98168
Contact: Jaimie How
Phone: 206-248-7900
Email: Jaimie@brennanheating.com
Scope of Work: Replace gas furnace & install new heat pump
Valuation: 5200.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 12/31/2013
Permit Expires:
Permit Form Type:
Civic Plus Number:
Status: COMPLETE
Assigned To: Launa Black
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
00930600003100 19430 45TH DR NE SCHWANS 111 Single Family
FREDERICK Residence-Detached
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866
CONTRACTOR
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor d BRENNHA971R9
CONTRACTOR Industri anes
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
CIO. Heat Pump and Furnace
02/03/2014 MECHANICAL 01/23/2014 01/24/2014 Marc Hayes Approved
ROUGH-IN Install.
Plan Reviews
Date Review Type Description Assigned To Review Status
12/26/2013 RESIDENTIAL Issued A.R. Launa Black
MECHANICAL
12/26/2013 RESIDENTIAL OK to issue z.Christopher Young
MECHANICAL
Fees
Fee Description Notes Amount
Mechanical Fee(Enter Fixture Fee) $50.00
Mechanical Base Permit Fee $25.00
Total $75.00
Attached Letters
Date Letter Description
12/30/2013 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
12/31/2013 Brennan Heating 48693507 cc $75.00
Outstanding Balance $0.00
Uploaded Files
Date File Name
12/26/2013 schwansmechapp.pdf
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
` Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone (360)403 3551 • FAX(360)403 3418
THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS, TWO(2)SETS
OF SPECIFICATION SHEETS AND TWO(2)SETS OF WASHINGTON STATE ENERGY CODE(if applicable).
Project Valuation: )f-5- of 011�)
ProjectAddress:1 "I q /3(�) 14 51h IX n e Parcel ID#: MCI 1,60(0 o c)�)I 0(1�)
Lot#: Subdivision:
Project Description: r 4 a I. f InA p a, a t
Owner: cz, Phone Number: a -
��5 ' of`� -t 151 b
Address: :3)OL L City: State: rZip Code:
Contact Person: xk mj t (D/ ( '(,, ,p'1 Phone Number:
Cell Phone: Fax: E-mail:
Address: City: State: Zip Code:
Please List quantity of fixtures below:
FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS
FURNACE OVER 100K FLOOR FURNACE SUSPENDED HTR/UNIT HTR
BOILER UP TO 3 HP APPLIANCE REPAIR SOLID-FUEL APPLIANCE
BOILER UP TO 4-15 HP AIR HANDLING UP TO 10K CFM FIREPLACE INSERT
BOILER UP TO 16-30 HP AIR HANDLING OVER 10K CFM VENTILATION SYSTEM
HEAT PUMP VENTILATION FANS OTHER
VENT HOOD DOMESTIC INCINERATOR
ALL OTHER UNITS FREESTANDING STOVE
Contractor:N-f Phone Number: CtW of f QG
Address:' `}�� h Ci ;��U`T,I�- State:� 0= ip Code
Contractor's License Number:_-t& ����- 4- Expiration: /Q 'a q7b3
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
sc bed property will be in accordance with the laws, rules and regulation of the State of Washington.
JApplicants Ignature Date ai rn►-�. - ��v
Print Applicants Name
FOR STAFF USE ONLY
Permit# Accepted By Amount Received Receipt#
P Date Received
2010 CJY
RL�ELT Ck 3
t
Ji
I
SPEC111FICATION S
General Model No.'XP14-018 XP14-024 XP14-030 XP1 -03 XP14-042 XP14-048 XP14-060
Data Nominal Tonnage 1.5 2 2.5 3.5 4 5
Connectio s Liquid line o.d.-in. 3/8 3/8 3/8 3 3/8 3/8 3/8
(sweat) I Vapor line o.d.-in. 3/4 314 3/4 7/ 7/6 7/6 1-1/8
t Refrigerant R-410A charge furnished 6 lbs.5 oz. 5 lbs. 14 oz.5 lbs. 10 oz.9 lbs. 5 0 E.11 lbs. 14 oz. 10 lbs. 7 oz. 12 lbs. 11 oz.
Outdoor Net face 3rea Outer coil 16.33 21.00 21.00 18.37 24.93 24.93 29.09
Coil sq.ft. Inner coil --- --- --- 18. 1 24.13 24.13 28.16
Tube diameter-in. 5/16 5/16 5/16 5/ 6 5/16 5/16 5/16
No.of rows 1 1 1 1 2 2 2
Fins per inch 22 22 22 2 22 22 22
Outdoor Diameter-in. 22 22 22 2 26 26 26
Fan No. of Blades 3 3 3 4 4 4
Motor hp 1/6 1/6 1/6 1 1/3 1/3 113
Cfm 2080 2670 2890 28 0 4347 4347 4550
Rpm 867 867 847 &9 843 843 830
Watts 168 177 200 2 5 299 299 307
Shipping (Data-lbs. 1 package 197 213 213 2 6 310 312 339
ELECTRICAL DATA
Line voltage data-60 h -1ph 208/230V 208/230V 208/230V 208/ 30 208/230V 208/230V 208/230V
'Maximum overcurrent protection(amps) 20 30 30 3 40 50 50
Minimum circuit ampa city 12.3 17.9 17.4 18 7 24.2 29.0 29.4
Compressor Rated Load Amps 9.0 13.5 13.1 14. 8 17.92 21.76 22.10
Locked Rotor Amps 48 58 64 77 112 117 125
Power Factor 0.98 0.98 0.98 0. 9 0.99 0.99 0.99
Outdoor Full Load Amps 1.1 1.1 1.1 1.1 1.8 1.8 1.8
Fan Motor Locked Rotor Amps 1.9 1.9 1.9 1. 2.9 2.9 29
OPTIONAL ACCESSORIES-ORDER SEPARATELY
Compressor Crankcase Heater 93M04 Factory Factory Factory Factory
Compressor Hard Start Kit 10J42
88M91
Compressor Low Ambi nt Cut- 45F08 ,
Off
Freezestat 3/8 in.tubing 93G35
5/8 in.tubing 5OA93
Indoor Blower Off Delay Relay 58M81
•Low Ambient Kit 54M89
Low Pressure Switch B pass 13W07
Thermostat
Mild Weatl ier Kit 33M07
Monitor Ki Service Lij ht 76F53
Outdoor Tt ermostat 56A87
Themnosta t Kit Mou iting Box 31461
Refrigerant L15 1-20 L15-41-30
Line Sets L15 1-40 L15-41-50
L15 65-30 L15-65-40
( ' L15-65-50
Field Fabricate
NOTE-Extremes of operating rarige are plus 10%and minus 5%of line voltage.
'Refdgerant charge sufficient for 15 ft.length of refrigerant lines.
'HACR type a'rcuit breaker or fu e.
'Refer to Nalidnal or Canadian ectrical Code manual to determine wire,fuse and disconnect size requirements.
'Crankcase Haler and Freezes t are recommended with Low Ambient Kit.WW
XP14-2 to 5 Ton Heat Pump /Page 6
I
SPECIFICA IONS
Ga Model No. SL280UH070V36 SL280UH09OV36B SL280UH09OV48B
Heiting Model No.-Low Nox SL280UH070XV3 A ... SL280UH090XV48113
Performance 'AFUE 80% 80% 80%
High Input-Btuh 66,000 88,000 88,000
Fire Output-Btuh 52,000 1 70,000 70,000
Temperature rise range-°F 40-70 40-70 40-70
Gas Manifold Pressure(in.w.g.) 3.5/10 3.5/10 3.5/10
Nat. Gas/LPG/Propane
Low Input-Btuh 43,000 57,000 57,000
Fire Output-Btuh 35,000 47,000 47,000
Temperature rise range-°F 25-55 25-55 25-55
Gas Manifold Pressure(in,w.g.) 1.7/4.9 1.714.9 1.7/4.9
Nat. Gas/LPG/Propane
High static-in.161 Heating 0.8 1 0.8 0.8
Cooling 1.0 1.0 1.0
Connections Flue connection-in. round 4 4 4
in. Gas pipe size IPS 1/2 1/2 1/2
Indoor Wheel nominal diameter x width-in. 10 X 8 10 X 9 11-1/2 X 9
Blower Motor output-hp 1/2 112 1.0
Tons of add-on cooling 2-3 2-3.5 2.5-4
Air Volume Range-cfm 606- 1345 498-1393 679-2002
Electrical Data Voltage 1 0 volts-60 hertz-1 phase
Blower motor full load amps 7.7 7.7 12.8
Maximum overcurrent protection 15 15 20
Shipping Data lbs.-1 package 128 143 154
NOTE-Filters and pit Dvisions for mounting are not furnished and must be field provided.
Annual Fuel Utilizati n Efficiency based on DOE test procedures and according to FTC labeling regule tions.Isolated combustion system rating for non-weatherized
furnaces.
2 Flue connection on he unit is 4 in,diameter.Most applications will require 5 in.venting and field suppl ed x 5 in.adaptor.See Venting Tables in the Installation
Instructions for deta led information.
SPECIFICATIONS
Gas Model No. SL280UH090V6 C SL280UH1 1 OV60C SL280UH135V60D
H6ating Model No.-Low Nox SL280UH090XV 0C SL280UH11OXV60C
Performance 'AFUE 80% 80% 80%
High Input-Btuh 88,000 110.000 132,000
Fire Output-Btuh 70,000 87,000 105,000
Temperature rise range-°F 35-65 35-65 40-70
Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5/10.0
Nat. Gas/LPG/Propane
Low Input-Btuh 57,000 72,0130 86,000
Fire Output-Btuh 47,000 58,00 69,000
Temperature rise range-°F 25-55 25-55 25-55
Gas Manifold Pressure(in.w.g.) 1.7/4.9 1.714.9 1.7/4.9
Nat. Gas/LPG/Propane
High static-in.w.g. Heating 0.8 0.8 0.8
Cooling 1.0 1.0 1.0
Connections Flue connection-in, round 4 4 24
i • Gas pipe size I PS 1/2 1/2 1/2
Indoor Wheel nominal diameter x width-in. 11-1/2 X 10 11-1/2 X 10 11-1/2 X 11
Blower Motor output-hp 1.0 1.0 1.0
Tons of add-on cooling 3-5 3-5 3.5-5
Air Volume Range-cfm 826-2305 812-2125 828-2257
Electrical Data Voltage 120 volts-60 hertz-1 phase
Blower motor full load amps 12.8 12.6 12.8
Maximum overcurrent protection 20 20 20
Shipping Data lbs.-1 package 173 181 199
<JOTE-Filters and avisions for mounting are not furnished and must be field provided.
Mnual Fuel Utilize ion Efficiency based on DOE test procedures and according to FTC labeling reguiatioi is.Isolated combustion system rating for non-weatherized
urnaces.
Flue connection o the unit is 4 in.diameter.Most applications will require 5 in.venting and field sup lied 4 x 5 in.adaptor.See Venting Tables in the Installation
'Instructions for det Ced information.
SL280UHV/Page 9