Loading...
HomeMy WebLinkAbout17624 Highland View Dr_BLD121_2026 17704 HIGHLAND VIEW DR - 17701 HILLSIDE CR•T 1"�1 HIGHLANE`JIEuV C•R 1 702 UPLAND DR -41 Aff- 1 630 HIGHLA D VIE DR 1 i ry c 627 HILLSID CRT 17fi27 HIGHLA D VIE'vV DR 1�28 LAND DR oos�oe0000i�oo 1 B24 IGHLAND VIEW DR • 721 HIGHLAND VIEW DR 17622 UPLA D DR 1 fi18 HIGHLAND VIEW DR 'q 17sz5 Hlusle•E :R, Eic� offlrlinRton titer r '' — r UPLAND DR 7fi12 HIGHLA D VIEW DR y � 9' F - � 6820 UPLAND DR 1�I�fi11 67TH AV N 17606 HIGHLAND VIE1M1'DR w 6900 PLAND DR JK Q J � 1 fiO3 HIGHLAND VIEW DR I 2 17600 HIGHLAND VIEW DR " '; - RESIDENTIAL ` SUBMITTAL REQUIREMENTS Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 - Phone (360)403 3551 • FAX(360)403 3418 ZONING VERIFICATION APPLICATION 72 hour turnaround Date: (,' -) -a o _? Address: / -76 )- 4/ k[7 G � /a idf I/; Plat: Owner/Applicant: Signature: Verification of accuracy and agreement to follow the City of Arlington Municipal Code Phone: (h) -36,0- 3 3 - G 3 ,17 (c) 1. Please check one: a. Single-family dwelling ❑ b. Duplex ❑ C.Addition ❑ d. Accessory structure 2. Proposed Dimensions: W) L) H) Total SF) �� S 3. Allowed Lot Coverage: Total Lot Size SF x 35% = SF 4. Actual Lot Coverage: (SF of all structures) _ (lot size) _ % (This square footage should include the footprint area of all structures on the property including: house, garages, sheds, covered patios, and decks permitted by the building code) 5. Septic Tank? t.- If so please provide Snohomish County Health Department approval and indicate on site plan. 6. How many trees greater than 12" diameter to be removed? 4— If any please indicate on site plan. 7. Describe Proposal (include cross street): OFFICIAL USE ONLY 'JUN 18 w3 PROPERTY ZONED �' "�/�b APPROVED E-1 DENIED _f WPERMIT OT '� Date: 09/01/2026 Permit#: 121 Permit Date: 06/18/2013 Review Date: 06/18/2013 Permit Type: RESIDENTIAL ZONING VERIFICATION Review Type: RESIDENTIAL ZONING VERIFICATION Target Date: 06/21/2013 Scheduled Time: Completed 06/19/2013 Date: Description: Proposal doesn't add on to house.ADU regs to vague to make distinctions on what constitues ADU area in this instance. Meets all ADU requirements in AMC 20.42.042 Review Status: Assigned To: Time In: Time Out: Hours: Property Information Parcel#: 00870600001700 EIDE ERIK R& STEFANIE A EIDE ERIK R& STEFANIE A 4612 CAMANO PL 17624 HIGHLAND VIEW DR ANACORTES,WA 98221 Zoning: I I I Single Family Residence - DetachedLot: Block: Permit#: 121 Permit Date: 06/18/13 Permit Type: RESIDENTIAL ZONING VERIFICATION Project Name: Ruth Eide Applicant Name: Applicant Address: Applicant, City, State, Zip: Contact: Phone: 360-333-0327 Email: Scope of Work: Mother In Law Apartment in Existing Unfinished Basement Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/21/2013 Permit Expires: Form Permit Type: Civic Plus Number: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00870600001700 17624 HIGHLAND VIEW EIDE ERIK R& 111 Single Family DR STEFANIE A Residence-Detached Plan Reviews Date Review Type Description Assigned To Review Status 06/18/2013 RESIDENTIAL ZONING No issues z.Christopher Young VERIFICATION 06/18/2013 RESIDENTIAL ZONING VERIFICATION 06/18/2013 RESIDENTIAL ZONING Zoning Verification z.Gary Schlagel VERIFICATION 06/18/2013 RESIDENTIAL ZONING No issues Fred Rapelyea VERIFICATION 06/18/2013 RESIDENTIAL ZONING Zoning Verification Tim Behan VERIFICATION 06/18/2013 RESIDENTIAL ZONING No issues VERIFICATION 06/18/2013 RESIDENTIAL ZONING Zoning Verification George Costanza VERIFICATION RESIDENTIAL ZONING 06/18/2013 VERIFICATION Zoning Verification Meghan Theriault 06/18/2013 RESIDENTIAL ZONING Zoning Verification Marc Hayes VERIFICATION 06/18/2013 RESIDENTIAL ZONING Zoning Verification Hank Shirley VERIFICATION RESIDENTIAL ZONING Proposal doesn't add on to house.ADU regs to vague to 06/18/2013 VERIFICATION make distinctions on what constitues ADU area in this instance.Meets all ADU requirements in AMC 20.42.042 06/18/2013 RESIDENTIAL ZONING Zoning Verification VERIFICATION Notes Date Note Created By: 06/18/2013 Proposed Mother In Law apartment in existing unfinished basement. Amy Rusko Uploaded Files Date File Name 06/18/2013 Eide Zoning Application.pdf 06/18/2013 Ruth Eide Site Plan.pdf 06/18/2013 17624 Highland View Dr.pdf FLOOR PLAN NOTES • WRITTEN DIMENSIONS TAKE PRECEDENCE OVER m SCALED DIMENSIONS.VERIFY ALL DIMENSIONS i AND CONDITIONS IN THE FIELD. 0 • CONFIRM ALL DOOR, WINDOW, CLOSET,AND ANY OTHER ROUGH OPENING SIZES WITH OWNERICONTRACTOR PRIOR TO WALL CONSTRUCTION. UNFINISHED/STORAGE • HALLWAYS TO BE MIN. 3'-3"WIDE. STORAGE# MECHANICAL AREA. • ALL WOOD IN CONTACT WITH CONCRETE MUST BE CONTRACTOR BID SEPARATE LINE PRESSURE TREATED MATERIAL. USE CORROSION ITEM FOR ADDING CONCRETE SLAB SEEN R ESEA ALREADY DUG DOWN. RESISTANT FASTENERS WHEN IN CONTACT WITH FOUNDATION WALL PRESSURE TREATED LUMBER. Z • ALL EXTERIOR WALLS (EXCEPT GARAGE)TO BE 0 w FRAMED WITH 2 x G STUDS AT IG"O.C. AND (n o I -5' 0-4` SHEATHED WITH I/2"055 PLYWOOD OR BETTER 10 WITH 15#BUILDING PAPER. z 1'-4" CL FLOOR TO CEILING 2 x 4 oz THIS WALL POSITIONED JUST 5'-0" • ALL INTERIOR WALLS TO BE FRAMED WITH 2 x 4 STUD WALL LEAVE I"AIR GAP INSIDE OF EXIST. FOOTING. SHORT — SOFFITED AREA FOR DUCTWORK STUDS AT IG"O.C.AND SHEATHED WITH I/2" ON ALL FURRED OUT WALLS EXISTING FOOTING AND UPSTAIRS PLUMBING GYPSUM GYPSUM WALLBOARD UNLESS NOTED OTHERWISE. RETAINING WALUFOUND.WALL WILL ❑ p ❑ ❑� HAVE TO BE CREATED FOR _ _ _ _ _ • ALL GLA55 TO HAVE LOW E (0.40)GLAZING AND TO _ MEET TEMPERED GLA55 REQUIREMENTS. CHANGE IN ELEVATION. 2468 i • PROVIDE SMOKE DETECTORS ON OR NEAR THE Ln 2 X 4 WALL FLOOR TO ADDITIONAL FND. PONY WALL 2 x 4 STUDS, CEILING OF EACH FLOOR IN ALL BEDROOMS,AND Ln CEILING. I"AIR GAP FOR I I FTG. UNDERPINNING Q 32 x GO THI WALL SHOULD LINE UP I TALL ENOUGH TO CONCEAL JUST OUTSIDE EACH BEDROOM.SMOKE ALL FURRED OUT WALLS m PREF SHO O WI H EXISTING STAIR FRAMEWORK I CONCRETE FOUND.WALL DETECTORS TO BE WIRED TO THE ELECTRICAL THIS BACK AREA NEEDS S.D. D ACCOMODATE 3'DOORWAY SYSTEM WITH BATTERY BACKUP(IRC R317.1 TO BE DUG DOWN N 2468 INTO OFFICE I I CANTILEVERED AREA R317.2). • • BEDROOMS TO HAVE AT LEAST ONE WINDOW EXISTING FENCE I 1 a? x UNDER I Y OVERHEAD MEETING THE FOLLOWING CONDITIONS: WINDOW m z H BEDROOM EX. FAN N STAIR N I SILLS TO BE WITHIN 44"OF FINISHED FLOOR WITH Q I I DOOR CUT CLOSET o A NET CLEAR OPENING OF 5.7 5Q. FT. MIN.THE z CONCRETE CUT AND �D BA H TO SIZE OFFICE I OFFSET WINDOW WITH OPENING TO HAVE MIN.CLEAR OPENING HEIGHT OF ❑ WINDOW WELL ADDED I I I OVERHEAD BUMP-OUT TO 24"AND WIDTH OF 20" (IRC SECTION R310). ❑z •.�1 TO MEET EGRESS I m o o STAIR UNDER z O �N ALLOW MORE LIGHT 0• TOILETS TO BE LOCATED IN AREA WITH MIN. 32" o N STORAGE NI WIDTH,AND HAVE CLEARANCE OF MIN. 21" IN m W FRONT OF TOILET.TOILETS TO BE LIMITED TO 1.6 m I 8' Q ol J I I - GALLONS PER FLUSH. z 3068 POCK • BATHROOM VANITY 512ING DEPENDS ON SPACE OF p HALLWAYS MIN. 3'-3" p (2) 2GG8 BYPASS (2) 2GG8 BYPASS ROOM.TOILET NEEDS AT LEAST IG" (18" PREFERRED) U o� EXIST. OF CLEAR FLOOR SPACE ON EACH SIDE OF TOILET, (2) 3068 BYPASS p O REMOVE POST STAIRS SHELF ROD FROM CENTERLINE OF TOILET,TO CLOSEST `r S.D. m S.D. PONY SHELVES ELF-FR EX. FAN/LIGHT FIXTURE,SIDEWALL,OR OTHER OBSTRUCTION. a 6� I � N X G BEARINGWALL COMBO. J I ING FENCE • PROVIDE EXHAUST FAN IN KITCHEN AT MIN. 100 EX. FAN 2 28 8 BI OLD CFM AND BATHROOMS AT MIN, 50 CFM.ALL FANS w AND DRYER EXHAUST TO BE VENTED TO OUTSIDE (� 03 DEPTH OF W/D CLOSET MUST CLOSET SIZES EQUAL EACH OF RESIDENCE. N WALL LINED UP WITH z 1° ACCOMMODATES 5'-0"SET PROVIDE FIRESTOPS AT ALL APPLICABLE REF Q � - W/D I I I ALLOW DEPTH OF STACKABLE � CURRENT SUPPORT I I N STACK 51RAGE m WA5HER/DRYER.CONTRACTOR OF BYPASS DOORS EXISTING STUD WALL •POSTS p LOCATIONS, INCLUDING HOLES AND ANY OPEN � PLEASE CONSULT APPLIANCE SPECS. AREAS. z 2 X G WALL • ALL ELEMENTS AND SWITCHES FOR FURNACE AND — 6'-I" 2'-G" 2'-1" MIN.3'-3" 6'-9" �? WATER HEATER TO BE 18"MIN.ABOVE SLAB. LLJ w N • PROVIDE P AIR GAP BETWEEN CONCRETE U-i o p OR WHERE MEETS POST o FOUNDATION AND FURRED OUT STUD WALLS. ALL Z bz Z ® � KITCHEN EXTERIOR WALLS AND/OR WALLS CONCEALING ANY O Q w w CONCRETE SLAB THROUGHOUT I I CONCRETE FOUNDATION WALLS TO BE INSULATED F Q w w p[ 2 X 4 WALL FLOOR I CUT EXISTING FOUNDATION U51NG BATT INSULATION. _ p w TO CEILING I REMOVE FOR DOOR • ALL BEAMS * HEADERS TO BE 4 x 10 D.F.#2 AT , Q Lu Z REPLACE EXIST. POSTS POSTS BASEMENT LEVEL UNO. U Q m WHERE FULL WALL STARTS. BEAMS W/NEW POSTS BEAMS REMOVE I I O � _ CHECK WITH HOMEOWNER.. POST Q Z� p O W REMOVE� I I SOFFITED AREA FOR ~ � � Z - ... Lu OR WHERE FULL WALL U � � Q STARTS. CHECK WITH POSTS ADD G X G DUCTWORK w = Z �- LU = HOMEOWNER. 10 G P05T LIVING RM CONCRETE NOTES O �- w w O w 171 12'-II" 2 x 4 WALL FLOOR • FILL UNDER SLABS ON GRADE TO BE MIN. 4" DEPTH O U TO CEILING GRANULAR MATERIAL COMPACTED TO 95%. DINING I • CONCRETE SLABS TO HAVE CONTROL JOINTS AT SMALL GAS FIREPLACE. 25 MAX. INTERVALS EACH WAY. O I PONY WALL OR FULL SEE FIREPLACE SPEC SHEET • WIRE MESH TO BE USED IN CONCRETE SLABS, TBD BY HOMEOWNER ENTRY WALL IN THIS SECTION FOR ROUGH OPENING SIZE. POSITIONED IN MIDDLE THIRD OF SLAB. O N PONY WALL EXISTING SLIDER • USE HIGH DENSITY POLYETHYLENE HIGH QUALITY [� C) � �t VAPOR RETARDER UNDER CONCRETE SLABS IN Z OUTSWING FRENCH DRS ch GARAGE AND BASEMENT. Lu N 0 = 2 X 4 PONY WALL FURR OUT L_ > • BEAM POCKETS IN CONCRETE TO HAVE 12" TO CONCEAL CONCRETE. HEIGHT TBD BY HOMEOWNER. ° AIRSPACE AT SIDES *ENDS WITH MIN. BEARING OF N 7040 5L 6068 ° ° ° ° 3� � CID a ° ° -EXISTING CRAWS P p ACE a ° ° I'-I SIDE DISTANCES ARE n 0 °° ' ° SUCK OUT�N FOUNDATION. °° ° a° APPROXIMATE DIMENSIONS • ALL BOTTOM PLATES AND ANY LUMBER IN Z Q O G,_0�� O ° e° ° �a CONTACT WITH CONCRETE TO BE PRESSURE (J� � 10 ° ° ° T-3"° ° °° °° CONCRETE-PAD BROOM G x G PT P05T5 TREATED. O O w a° FI�11SH M1N.4'THICK ° TYP. 3 PLACES w = Z O U ~ ° ° Low Q w II'-G" II'-G" IG" DIA.CONCRETE COLUMN PROJECT INFO. ►— �o Q pO[ w 0. FOOTINGS LET IN GRADE 24" MIN. Q > EQUIDISTANT SPACING ON P05TS TYP. 3 PLACES THIS PROJECT IS FOR CONSTRUCTION OF AND EQUIDISTANT ON SIDES OF A BASEMENT APARTMENT SPACE. FRENCH DOORS AND SLIDER APARTMENT WILL OCCUPY PREVIOUSLY UNFINISHED CRAWL SPACE IN FINISHED DRAWN JAD 23'-5 I/2"KEY Ir SINGLE-FAMILY RESIDENCE. SCALE I/4" = I'-0" APPROX. LENGTH OF CONCRETE PAD NEW SQUARE FOOTAGE: 9G8 S.F. DATE OG/13/13 NEW STUD WALL DOES NOT INCLUDE ANY PREVIOUSLY JD JOB# 1004RE13-FIDE FINISHED SPACES OF HOUSE. EXISTING STUD WALL ® NEW POST FLOOR PLAN SHEET ❑ EXISTING POST SCALE: 1/4" = V-0" REMODELED FLOOR PLAN EXISTING WALLS AND FOUNDATION ARE LIGHTER LINE WEIGHT Al NEW WALLS AND CHANGES ARE DARKER LINE WEIGHT 1 OF 4 m FRAMING NOTES • WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. • ALL BEAMS AND HEADERS TO BE 4 x 8 D.F.#2 UNO. BEAM SCHEDULE BI 4x8DF#2 (n Z B2 5-1/4 x 9-1/2 VL 2.0 3100 DF(FLUSH) O w Q B3 5-I/4 x 9-1/2 VL 2.0 3100 DF(FLUSH) N p 54 G x 8 DF#1 z p[ �w 55 Gx8DF#1 D2 BG Gx8DF#2 137 Gx8DF#2 FOUND. FOOTING Ln B8 4x8DF#2 Ln — B9 4 x 8 DF#2 BIO 4 x 8 DF#2 co 0 5; •� O O mU DI z UNDERPIN FOOTING z FOUND. ENERGY CODE NOTES o 0 o FOOTING • U_' Z • CONTRACTOR TO ADD ADDITIONAL FRAMING OR BLOCKINGLLJ ct� AS REQUIRED TO MEET CURRENT ENERGY CODE O O I REQUIREMENTS. C) t 0 rNIN Z 0 • AIR LEAKAGE.SOLE PLATE 15 TO BE CAULKED OR GLUED TO a z Ua w p t FLOOR. RIM JOIST BETWEEN STORIES TO BE CAULKED/SEALED. O o I N � I BI ALL HOLES IN BUILDING ENVELOPE ARE TO BE d U p B9 I I O I CAULKED/SEALED INCLUDING BUT NOT LIMITED TO ELECTRICAL, PLUMBING* HVAC PENETRATIONS. OUTLETS, o J N EXTERIOR WALLS OR SWITCH OCEILI CEILINGS RE TO BXES AND E C U KED/S FIXTURES OEAL D WITH APPROVED SEALANT,OR HAVE FOAM GASKETS INSTALLED. W ALL RECESSED LIGHTS ARE TO BE IC RATED,AIR TIGHT* U SEALED TO SURROUNDING GWB. ROUGH OPENING AROUND Q ALL WINDOWS * DOORS TO BE SEALED/CAULKED. • ALL CEILING EXHAUST FAN DUCTING TO BE INSULATED AS PER CODE,TO HAVE AS FEW BENDS AS POSSIBLE,AND TO Z J —o— — —❑ — — — — — — TERMINATE AT THE EXTERIOR OF THE BUILDING. • INSULATION TO FILL ALL EXTERIOR WALL CAVITIES. DO NOT Z COMPRESS.CUT TO FIT AROUND WIRES, PIPES �OUTLET � U BOXES. Z ~ Lu Z C) • ALL HVAC DUCTS INSTALLED OUTSIDE THE HEATED HABITABLE Q Lu LLJ THIS FOOTING SLIGHTLY HIGHER. SPACE TO HAVE SEALED JOINTS,CORNERS* BOOTS,AND (L MAY NEED TO BE GROUND DOWN INSULATED IN ACCORDANCE WITH WSEC 2009 EDITION Q LLJ TO MEET ELEVATION. SPECIFICATIONS ("WSEC 2009"). Q Lu z • A ONE PERM OR LESS VAPOR RETARDER(IE: KRAFT PAPER, Q Q] o I I PVA PAINT, ETC.) 15 TO BE INSTALLED ON THE WARM 51DE OF W J z Q ALL INSULATION. p Z Lu STUD WALL HANG FLOOR JOISTS FROM ,\ • ALL RECESSED LIGHT FIXTURES IN THE THERMAL ENVELOPE TO F- W r U O p + BEAM TO ALLOW SUFFICIENT BE CERTIFIED UNDER ASTM E-283 AND 50 LABELED,OR W HEADROOM IN LIVING SPACE SEALED AROUND THE EXTERIOR IN AN APPROVED MANNER TO = Z tL p Ow O STUD WALL BE AIR TIGHT. O O z O N B2 B3 • ALL WATER PIPES IN UNHEATED SPACES TO BE INSULATED IN w u FLUSH BEAM FLUSH BEAM — — BEAM/HEADER ACCORDANCE WITH WSEC 2009. w I EXIST. BEAM/HEADER • EXTERIOR DOORS TO BE ADJUSTED 50 WEATHER-STRIPPING, 12'-II" THRESHOLD, � DOOR SWEEP ARE WORKING PROPERLY*SEAL RAFTER/J015T WELL rl • BLOWN-IN ATTIC INSULATION TO BE INSTALLED IN STRICT O — — — — — FOUNDATION CONFORMANCE WITH MANUFACTURERS RECOMMENDATIONS FOR DENSITY*COVERAGE. PROVIDE VENT BAFFLES AS NEW F05T REQUIRED* INSULATE*WEATHER-STRIP ATTIC ACCESS U B8 I I ® DOOR. Lu 0 L N O ❑ EXISTING P05T . PROVIDE MAKEUP AIR WITH FRESH AIR DUCTED DIRECTLY E2 N O FOUNDATION INTO THE RETURN AIR PLENUM OF THE FURNACE SYSTEM. C) 0 WALL INSULATE THE DUCT IN ACCORDANCE TO WSEC 2009. PROVIDE DAMPER TO REGULATE INCOMING FRESH AIR. z Q — 54 B5 • ALL GAS COMBUSTION APPLIANCES, EXCEPT STOVES* (s) g > O CLOTHES DRYERS,TO HAVE COMBUSTION AIR DUCTED LLJ = Z O — — DIRECTLY TO THEM. (� • ALL COMBUSTION EXHAUSTS TO BE SEPARATED BY A MIN. 3' p = O VERT.* 10' HORIZ. Q z Lu F#2 @ q"O.G. UJ N — U co 2,c 6 G x G PT PO5T5 �- C9 ::3 Q I B7 I I I TYP. 3 PLACES (n L Q o - -� INSULATION VALUES 7 WALLS DRAWN BY JAD IG" DIA CONCRETE COLUMN D3 FOOTINGS LET IN GRADE 24" MIN. ABOVE GRADE BELOW GRADE SCALE 1/4" = I'-0" TYP. 3 PLACES R-21 R-21 DATE OG/13/13 10 CEILING JD JOB# 1004REI3-FIDE FLAT VAULTED R-49 R-38 5H EET FLOOR T A M I N G FOUNDATION PLAN CRAWL SPACE SLAB ON GRADE R-30 R-10 : 114" = I'-O" A2 2 OF 4 m 0 N l0 O 1/2"GYP. BOARD TYP. Z R-21 BATT INSULATION O w (n Q z w UNFINISHED/CRAWL SPACE.THIS AREA CAN REMAIN AT RAISED LEVEL. CONTRACTOR °GRADE EXIST. FOUNDATION WALL TO BID OUT C05T OF CONCRETE SLAB IN dl Ln TH15 AREA. MECHANICAL EQUIPMENT SUCH Ln m AS FURNACE AND/OR HOT WATER WILL NEED TO BE HOUSED IN THIS AREA. ��/j/ /% ° BREAK OFF FOOTING /— O PROJECTION 00 o TH15 AREA ALREADY DUG ° DOWN.SHOULD MAKE GOOD ( CU O CURRENT POSTS PASSAGE TO CRAWL SPACE. r ° J 3 x 4 POST 4 x G P05T e �, FINISH SURFACE PER PLAN z 3 x 4 POST 4 x 6 POST 3 x 4 POST _ C) p z + NEW 4"GONG SLAB W/WIRE -� (I)#4 REBAR CONT. ° n AT TOP OF WALL 5" �p MESH IN MID THIRD OF SLAB o � p 5'-0" 5'-0" 5'-O" 6'-8" ° . ° < #4 VERT. REBAR @ 18'O.G. ° Q @� 41 4"EMBED INTO EXIST. FTG. a ° zQ THIS FOOTING AT HIGHER W/EPDXY ° e ° U ° ELEVATION THAN OTHERS. OKAY TO LEAVE AS 15. • EXIST.JOISTS ARE 9-1/2"TALL TJI STYLE BEAMS ARE 4 x 8 (2)#4 REBAR CONT. IN FOOTINGS r111 N U THIS AREA WILL NEED TO BE DUG OUT (APPROX. 18"OR 50)TO MEET LEVEL AT WEST OF HOUSE Z � FOUNDATION UNDERPINNING z LLJ EXISTING STUD WALLS DI TH15 FOOTING SLIGHTLY HIGHER. AND STAIRCASE SCALE: 3/4" = I'-0" W MAY NEED TO BE GROUND DOWN z bz Z TO MEET ELEVATION. Q l W : O Q Lu OL 3 x 4 POST 4 x G POST 3 x 4 P05T 3 x 4 POST 3 x 4 POST (n LL.J _ _ Z - - t — - -o - - e-- - - (s) w C O z W 2'-1" 5-0" 5'-0" 4'-G' 3'-II" 2'-G" EXISTING FINISHED REC ROOM F— � U W (s) W uj P05T SPACING DIMENSIONS AREa- APPROXIMATE O ►L O (vOZ (L/ IL a� EXIST. FRAMING ALL FOOTINGS ARE ALREADY IN PLACE. USE EXIST. FOOTINGS FOR ANY POST AND BEAM O FOUNDATION WALL ALTERATIONS. O EXIST. STRIP FOOTING 3 x 4 P05T 4 x G POST 3 x 4 P05T 3 x 4 POST 3 x 4 POST O - - � — - -o —o— - - > N O (1)#4 REBAR CONT. O 2'-I" 5'-0" 5'-0" 3'-G" 5'-O" 2'-5 AT TOP OF WALL ° � o < P05T SPACING DIMENSIONS ARE c) FINISH SURFACE PER PLAN /\ W = O APPROXIMATE O i� NEW 4"CONC.SLAB W/WIRE + k m MESH IN MID THIRD OF STAB 4"EMBED INTO EXIST.�v #4 VERT. REBAR @ 15"O.C. _ CONCRETE SLAB WILL BE POURED Ff G. Q � z Q j UP TO TOP OF FOOTING W/EPDXY LtJ N z U a° CURRENT CRAWL SPACE ° Q Qa- ACCESS 8 °�D Q G" G" (2)#4 REBAR CONT. DRAWN BY JAD IN FOOTINGS SCALE 1/4" = 1'-0" DATE OG/13/13 ST i N G CRAWL SPACE JD JOB# 1004RE13-FIDE � LNG SCALE: 114" - 1�-0�� FOOTING UNDERPINNING.DERPI N N SHEET D SCALE: 3/4" 3 OF 4 cn 0 N O MATCH SAVE DIMENSION ON REST OF HOUSE. DINING WINDOW DRAWN AT I'-0". 7040 5L GOGB O T WING N Z E— O w Q TOP OF FOUNDATION WALL _� p 00 LLBLL,� z CURRENT GRADE p[ NEW GRADE Ln ENTRY FRENCH DRS EXISTING SLIDER NEW GRADE Ln CONCRETE SLAB BROOM EXISTING CONCRETE SLAB O FINISH MIN.4"THICK c0 TIE IN WITH EXISTING SLAB b� OR REPLACE EXISTING. O O • 0 U WEST ELEVATION -c Q z � SCALE: 1/4" = 1'-0" z tu CONTRACTOR CHECK PITCH owC EXISTING FENCE AND MATCH REST OF HOUSE. O 12 � U =� 1 x 6 FASCIA.CONTRACTOR I x 4 TRIM.CONTRACTOR 4 CHECK TO MAKE SURE CHECK TO MAKE SURE MATCHES REST OF HOUSE. MATCHES REST OF HOUSE. BEDROOM WINDOW KITCHEN WINDOW DINING WINDOW LLJ 4G3G 5L 4030 5L 4030 PIC () Z J GxGPTP05T — Q> WINDOW WELL. ~ �C Z SEE NOTES ON CURRENT GRADE LLJ U WINDOW EGRESS. Z Imo— Q — ZUi Z _ NEW GRADE O Lu C2 a- Q w OL — — — — — — — — — — — — — — — — — — — — — — — — — — — � Qm CONCRETE SLAB L LLJ O 4'-C)" IG" DIA. CONCRETE COLUMN z to ol FOOTINGS MIN. 24" DEEP U W = NORTH ELEVATION o o o CL SCALE: 1/4" = 1'-0" � COMPOSITE SHINGLES MATCH REST OF HOUSE 1/2"PLYWOOD SHEATHING O O MATCH PITCH TO 2 x G � N O REST OF HOUSE 12 OL N O 4 CANTILEVERED SECTION u FOR UPSTAIRS FIREPLACE O 2x BLOCKING Q I,- o OFFICE WINDOW LLJ = Z O CUT RAFTER TAILS O TO MATCH TRUSSES 502G E EXISTING FENCE TOP OF FOUNDATION WALL Q O U MATCH FASCIA / LLJ N Z r/ TO REST OF HOUSE / FL- U a/ Q EXIST. REC ROOM / DECKING CONT. METAL RECESSED LIGHTING GUTTER I DRAWN BY JAD 6 x 8 BEAM DF#2 2'-0" Ll-------;�7CURRENT GRADE SCALE AS SHOWN FASCIA TO EXTEND _ BEYOND GUTTER MATCH REST OF G x G P05T /13/13 0. D JOB# 10ATE OG/13/13 -FIDE HOUSE JD 5OUTH ELEVATION 5HEET SCALE: 1/4" = 1'-0" - NEW SAVE DETAI LA4 4OF4