Loading...
HomeMy WebLinkAbout18527 Ballantrae Dr_BLD6963_2026 i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation Addition/Alteration/Repair ❑ Gas Piping 18527 BALLANTRAE DR 3361 Property Address: Project Valuation: Lot#: - Parcel ID No.: 00865900001000 Preferred Contact: ❑ Owner 0 Contractor Project Description: GAS WATER HEATER SWAP Owner Name: HEATHER JOHNSTON Home No.: Email Address: heatherjohnston@frontier.com Cell No.: 4252447274 18527 BALLANTRAE DR ARLINGTON MailingAddress: City: State: WA Zip:98223 Contractor Name: CM HEATING Office No.: 4252590550 Email Address: PERMITS@CM HEATING.COM Cell No.: Mailing Address: 1500 INDUSTRY ST#200 City: EVERETT State: WA zip: 98203 L&I Contractor License Number: CM H EAH L751 LW Expiration Date: 5/31/2027 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ s/s" 713/4" ❑ 1" ❑ 11/2" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units x $ 15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 7 Boiler<100Btu h>3h x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans x $ 15.00 = Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h x $ 15.00 = Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 = Gas Pipin <_5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 mechanical code,not otherwise specified Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<_ 100 Btu/h x $ 15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes (part of Air x $ 10.00 Conditioning System) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired 1 x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 Residential Mechanical Application For Instruction/Checklist,please click here Site Address: 18527 BALLANTRAE DR Project Name: I JOHNSTON PERMIT Project Valuation: 3674 Preferred Contact: Owner Contractor Project Description: GAS WATER HEATER SWAP Owner Details Owner Name: HEATHER JOHNSTON Home No.: NA Email Address: heatherjohnston@frontier.coi Cell No.: 14252447274 Mailing Address: 18527 BALLANTRAE DR City: ARLINGTON State: I WA Zip: 98223 Contractor Details Contractor Name: CM HEATING Office No.: 14252590550 Email Address: PERM ITS@CMHEATING.C( Cell No.: Mailing Address: 11500 INDUSTRY ST#200 City: EVERETT State: I WA Zip: 98203 L&I Contractor License Number: I CMHEAHL751 LW Expiration Date: //31/ 0027 Proposed Piping Material: O CSST O Brass 0 Black Steel Galvanized Steel Other Proposed Piping Size: 1/2" 5/8" 3/4" III 1 1/2" 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Units Additional Plan Review fees Air Cond. Unit< or equal to 100Btu/h Air Cond. Unit>100Btu/h 1 Air Cond. Unit>500BhVh Air Handling Units Base Mechanical Fee Boiler<100Btu/h>3hp Boiler>1 million Btu/h<50hp Boiler>1.5 million Btu/h<50hp Boiler>100Btu/h 3-15hp Boiler>500Btu/h 15-30hp Commercial Hoods -Type I Commercial Hoods -Type II Diffusers Dryer Ducting Ductwork(drawings required) Evaporative Coolers ExhaustNentilation Fans Fireplace/Insert/Stove Forced Air Heat< or equal to 100 Btu/h Forced Air Heat>100 Btu/h Gas Clothes Dryer Gas Fired Air Conditioning Unit<or equal to 100 Btu/h Gas Fired Air Conditioning Unit>100 Btu/h Gas Fired Air Conditioning Unit>500 Btu/h Gas Piping<or equal to 5 units Gas Piping for each additional unit> 5 Heat Exchangers Heat Pump-Condensing Unit Hot Water Heat Coils Miscellaneous Appliance - regulated by mechanical code, not otherwise specified Package Units< or equal to 100btu/> 100 Btu Range/Cook top-Gas Fired Refrigeration Unit < or equal to 100Btu/h Refrigeration Unit>100Btu/h Refrigeration Unit>500Btu/h Re-inspection fee Residential Range Hood Unit Heaters < or equal to 100 Btu/h F Unit Heaters >100 Btu/h Variable Air Volume Boxes (part of air conditioning system) Wall Heaters - Gas Fired Water Heater- Gas Fired 1 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Print Name: I SABRINA KENNARD Date: 07/17/2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 18527 BALLANTRAE DR Permit#: 6963 Parcel#:00865900001000 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS WATER HEATER SWAP Valuation:3674.00 OWNER APPLICANT CONTRACTOR JOHNSTON JANET CM Heating CM HEATING INC 18527 BALLANTRAE DR 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 ARLINGTON,WA 98223-5038 EVERETT,WA 98203 EVERETT,WA 98203 4252590550 425-259-0550 L1C:CMHEAHL750LP EXP:06/25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LIC:605890285 OM:06/17/2027 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LTC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: STORIES: 0 CONST. TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC IO/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. cv ► 6 ! OLtfL- 07/20/2026 '� �D �- Applicant Signature I Data Building Official Date CONDITIONS Adhere to approved mechanical equipment Permit shall be onsite for inspections Call for inspections The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals frorn the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/20/2026 Processing/Technology $25.00 07/20/2026 Inspection $75.00 07/20/2026 IVbchanical Base $25.00 07/20/2026 Water Heater(Tank) $25.00 Total Due: $150.00 Total Payment: $150.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 6963 Permit Date: 07/17/26 Permit Type: RESIDENTIAL MECHANICAL Project Name: JOHNSTON PERMIT Applicant Name: CM Heating Applicant Address: 1500 INDUSTRY ST#200 Applicant, City, State, Zip: EVERETT,WA 98203 Contact: SABRINA KENNARD Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: GAS WATER HEATER SWAP Valuation: 3674.00 Square Feet: 0 Number of Stories: 0 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 07/20/2026 Permit Expires: 01/19/2027 Form Permit Type: RESIDENTIAL MECHANICAL Civic Plus Number: PA26-0487 Status: COMPLETE Assigned To: LaNay Hendrick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00865900001000 18527 BALLANTRAE DR JOHNSTON JANET FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R15. 08/12/2026 MECHANICAL Please call when on the way. 08/13/2026 08/13/2026 BUILDING Approved FINAL Homeowner:425-244-7274 Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Mechanical Base Permit Fee $25.00 Water Heater(Tank) $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 07/20/2026 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/20/2026 XBP Conf: $150.00 322792197 07/20/2026 mill cc LaNay Hendrick $4.50 Outstanding Balance $0.00 Uploaded Files Date File Name 07/20/2026 33310359-615 JOHNSTON-APP.pdf 07/20/2026 33310358-civicgov4.com wa arlingtopermits edit 615.pdf 07/20/2026 33310357-residential gas natural atmosuheric vent naeca compliant snecsheet 1101.pdf 07/20/2026 33310356-Permit5.pdf 07/20/2026 33310325-20260720143604.pdf CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18527 BALLANTRAE DR Permit#: 6963 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00865900001000 DATE OF ISSUANCE. Scope of Work: GAS WATER HEATER SWAP Valuation: 3674.00 OWNER APPLICANT CONTRACTOR JOHNSTON JANET CM Heating CM HEATING INC 18527 BALLANTRAE DR 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 ARLINGTON,WA 98223-5038 EVERETT,WA 98203 EVERETT,WA 98203 4252590550 425-259-0550 LIC:CMHEAHL750LP EXP:06/25/2027 LIC:CMHEAHL751W EXP:06/17/2027 LIC:605890285 EXP:06/17/2027 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: STORIES: 0 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. �G 07/20/2026 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved mechanical equipment Permit shall be onsite for inspections Call for inspections The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/20/2026 Processing/Technology $25.00 07/20/2026 Inspection $75.00 07/20/2026 Mechanical Base $25.00 07/20/2026 Water Heater(Tank) $25.00 Total Due: $150.00 Total Payment: $150.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail BRADFORD WHITE" W A T E R H E A T E R S Residential Atmospheric Vent Gas Water Heater The Atmospheric Vent FVIR Defender Safety System®Models Feature: ■ Bradford White ICON System'*—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter.A standard,off-the-shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. —Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and tighter temperature differential. - —Advanced Temperature Control System—Microprocessor controls burner operation for consistent and accurate water temperature levels up to 160°F (71°C). —Intelligent Diagnostics—Exclusive multicolor LED light indicates operation status/service required. ■ Defender Safety System®— Designed to be the safest, most reliable flammable vapor ignition resistant system in the industry with a proven track record since 2003. —Advanced ScreenLok®Technology Flame Arrestor Design—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. —Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapors burning inside of the combustion chamber or restricted air flow. —Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under normal conditions. —Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner. ■ Vitraglas®Lining with Microban®—An exclusively engineered enamel formula that provides superior tank protection from the corrosive effects of water; and r with Microban®antimicrobial product protection to help prevent the growth of __- bacteria, mold and mildew on the surface of the tank lining. ■ Hydrojet®Total Performance System—Sediment reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank. ■ 3x4"Snap Lock" Draft Diverter—Allows either 3" (76mm)or 4" (102mm)vent connections with inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" (102mm) "Snap Lock" Draft Diverter. LAN r ■ Water Connections—NPT factory installed dielectric waterway with heat traps. ■ Protective Anode Rod—Provides added protection against corrosion for long- Photo is of term,trouble-free service. RG240T6N ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ NOx Emissions—Less than 40 ng/J. FEATURING: ■ Small Diameter Models Available—for limited space installations. ■ T&P Relief Valve—Installed. Icorv u�7u J System May vary by region MICROBAn� 6 or 10-Year Limited Tank Warranties/6 or 10-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA,Canada,and Puerto Rico.Some states do not allow limitations on warranties.See complete copy of the warranty included with the heater. Microban®antimicrobial product protection helps prevent the growth of bacteria,mold and mildew that may affect the product.The built-in antimicrobial properties do not protect users or others from disease-causing organisms.Microban®is a registered trademark of Microban Products Company. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7,634,976;5,660,165;5,954,492;6,056,542;6,935,280;5,372,185;5,485,879;5,574,822;7,971,560;7,992,526;6,684,821;7,334,419;7,866,168; 7,270,087;7,007,748;5,596,952;6,142,216;7,699,026;5,341,770;7,337,517;7,665,211;7,665,210;7,063,132;7,063,133;7,559,293;7,900,589;5,943,984;8,082,888;5,988,117;7,621,238;7,650,859;5,761,379;7,409,925;5,277,171; 8,146,772;7,458,341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS:2,314,845;2,504,824;2,108,186;2,143,031;2,409,271;2,548,958;2,112,515;2,476,685;2,239,007;2,092,105; 2,107,012.Defender Safety System®,ScreenLok®,Hydrojet®and Vitraglas®are registered trademarks of Bradford White®Corporation.Microban®is a registered trademark of Microban Products Company. 1101-G-0822 Residential Atmospheric Vent Gas Water Heater Atmospheric Vent Models Meet or exceed ASHRAE 90.1(latest edition).C.E.C.Listed NATURAL GAS AND LIQUID PROPANE GAS Recovery efficiency ranging up to 80% Model Rated DOE LP First Uniform Recovery at Model Rated DOE LP First Uniform Recovery at Number Nominal Rated BTU/Hr. BTU/Hr. Hour Energy 901 Rise* Number Nominal Rated kW kW Hour Energy 50°C Rise* Volume Storage Input Input Rating Factor LP LP Volume Storage Input Input Rating Factor LP U.S. Imp. Volume U.S. Imp. U.S. Imp. Volume Liters/ Liters/ Gal. Gal. Gal. Gal. GPH GPH GPH GPH Liters Liters Liters Hour Hour RG130T6N* 30 25 29 27,000 27,000 46 0.54 29 24 29 24 RG130T6N* 114 110 7.9 7.9 174 0.54 110 110 RG230T6N* 30 25 29 32,000 31,000 60 0.60 34 28 33 23 RG230T6N* 114 110 9.4 9.1 227 0.60 129 125 RG230S6N 30 25 29 30,000 26,000 49 0.54 32 37 32 27 RG230S6N 114 110 8.8 7.6 186 0.54 121 121 RG140T6N* 40 33 38 34,000 34,000 64 0.59 37 31 37 31 RG140T6N* 151 144 10.0 9.9 243 0.59 139 139 RG240T6N* 40 33 38 40,000 36,000 75 0.64 43 36 34 33 RG240T6N' 151 144 11.7 10.6 284 0.64 163 129 RG240S6N* 40 33 38 40,000 38,000 69 0.58 43 36 41 34 RG240S6N' 151 144 11.7 11.1 262 0.58 163 155 RG150T6N* 50 42 47 34,000 34,000 75 0.63 37 31 37 31 RG150T6N* 189 178 10.0 9.9 284 0.63 139 139 RG250T6N' 50 42 48 40,000 36,000 81 0.63 43 36 41 34 RG250T6No 189 182 11.7 10.6 307 0.63 163 155 RG250L6N 48 40 47 40,000 38,000 77 0.63 43 36 41 34 RG250L6N 182 178 11.7 11.1 292 0.63 163 155 RG250S6N' 50 42 47 50,000 48,000 75 0.63 54 45 52 45 RG250S6N' 189 178 14.7 14.1 284 0.63 204 197 Model A B C D E F G H J M S Approx. Number Floor to Jacket Vent Floor to Floor to Floor to Floor to Depth CIL of Water Gas Shipping Exhaust Dia. Size T&P Gas Top of Water Water Conn. Conn. Weight Conn. Conn. Conn. Heater Conn. Conn. NPT Size in. in. in. in. in. in. in. in. in. in. in. lbs. RG130T6N* 593/4 16 3or4 493/4 13 561/4 57 191h 8 3/4 1/2 106 RG230T6N* 593/4 18 3or4 493/4 13 561/4 57 211h 8 3/4 1/2 116 RG230S6N 491/4 20 3or4 387/8 13 453/4 461/2 231/2 8 3/4 112 113 RG140T6N* 61 M6 18 3 or 4 515/8 13 5713h6 591/16 211/2 8 3/4 1/2 132 RG240T6N* 601/3 20 3or4 493/4 13 565/8 573/8 231h 8 3/4 1/2 134 RG240S6N* 511/16 22 3 or 4 411/16 13 481/16 481/16 251/2 8 V4 1/2 139 RG150T6N* 601/3 20 3or4 4915/16 13 565/8 573/8 231h 8 3/4 1h 148 RG250T6N* 60Va 22 3or4 4915/16 13 565/3 573/3 251h 8 3/4 1/2 154 RG250L6N 51 M6 24 3 or 4 4011/16 13 481/16 4813/16 271/2 8 3/4 1/2 170 RG250S6N* 601/8 22 4 4915/16 13 565/3 573/3 251/2 8 3/4 1/2 167 Model A B C D E F G H J M S Approx. Number Floor to Jacket Vent Floor to Floor to Floor to Floor to Depth CIL of Water Gas Shipping Exhaust Dia. Size T&P Gas Top of Water Water Conn. Conn. Weight Conn. Conn. Conn. Heater Conn. Conn. NPT Size mm. mm. mm. mm. our. mm. mm. mm. mm. mm. mm. kg. RG130T6N* 1518 406 76or102 1264 330 1429 1448 495 203 19 13 48 RG230T6N' 1518 457 76or102 1264 330 1429 1448 546 203 19 13 53 RG230S6N 1251 508 76or102 987 330 1162 1181 597 203 19 13 51 RG140T6N* 1557 457 76or102 1311 330 1468 1513 546 203 19 13 60 RG240T6N* 1527 508 76or102 1264 330 1438 1457 597 203 19 13 61 RG240S6N* 1310 559 76or102 1043 330 1221 1240 648 203 19 13 63 RG150T6N* 1527 508 76or102 1268 330 1438 1457 597 203 19 13 67 RG250T6N* 1527 559 76or102 1268 330 1438 1457 648 203 19 13 70 RG250L6N 1310 610 76or102 1033 330 1221 1240 699 203 19 13 77 RG250S6N* 1527 559 102 1268 330 1438 1457 648 203 19 13 76 Propane models feature a Titanium Stainless Steel propane burner.For Propane(LP)models change suffix"N"to"X". For 10 year models,change suffix from"13"to"10". * Based on manufacturer's rated recovery efficiency. C • Models feature optional top TO location and must be specified when ordering. Note:RG230S6N and RG250L6N do not have top T&P option. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. General: Meets NAECA Requirements. optional Top T&P valve All gas water heaters are certified at 300 PSI test pressure(2068 kPa)and 150 PSI working pressure (1034 kPa).All water connections are 33%" NPT (19mm)on 8"(203mm)centers.All gas connections are T(13mm). J �{ All models design-certified by CSA International (formerly AGA/CGA) to 0 A ANSI standard Z21.10.1. F D Dimensions and specifications subject to change without notice in H a~ M G accordance with our policy of continuous product improvement. 1 Suitable for Water(Potable)Heating and Space Heating. _ Toxic chemicals,such as those used for boiler treatment,shall NEVER be M f introduced into this system. This unit may NEVER be connected to any existing heating system or component(s)previously used with a non-potable _13- E water heating appliance. -13RADFORD WHITE IS- AMSERICAN Sales:800-523-2931 •Fax 215-641-1612 STRONG. 2417 Technical Support:800-334-3393•Email techserv@bradfordwhite.com Products made by Bradford White are manufactured in the United States using the finest raw materials and components from around the world. Built to be the Best 1101-G-0822 02022,Bradford White Corporation,USA.All rights reserved. Printed in U.S.A.