Loading...
HomeMy WebLinkAboutHarmony at Arlington - Sewer Submittals HARMONY AT ARLINGTON SUBMITTAL CONTRACTOR: BYK CONSTRUCTION SEWER ICONIX QUOTE # U2510008532 0 1CONIX 1687 Port Drive T 360.707.5958 waterworks Burlington, Washington F 360.757.1643 USA 98233 iconixww.com Atkore Heritage Plastics PVC DR 35 Gasketed Sewer Pipe - West Conforms to ASTM D 3034 • Product manufactured with one integral gasketed bell per length • Each spigot end is beveled to facilitate assembly and reference marked to indicate proper insertion depth Pipe is produced in 14-foot and 20-foot laying lengths Standard color is green IL Trade Part Length Dimensions Crate r Size Number (ft) (in) Quantity 4 3040014G 14 4.215 3.96 0.120 107 1,176 4 304002OG 20 4.215 3.96 0.120 107 1680 6 3060014G 14 6.275 5.89 0.180 244 490 6 306002OG 20 6.275 5.89 0.180 244 700 8 3080014G 14 8.400 7.89 0.240 445 280 8 308002OG 20 8.400 7.89 0.240 445 400 10 30100014G 14 10.500 9.86 0.300 699 168 12 30120014G 14 12.500 11.74 0.360 1,003 112 15 30150014G 14 15.300 14.37 0.437 1,491 84 www.atkore.com/heritageplastics 1-81OW Sewer Pipe D3034 Gasketed Data Sheet 05.21 PVC GASKET SEWER PIPING SYSTEMS Ringmtiotel M U N I C I PAL SYSTE M S PVC SEWER PIPING SYSTEM MANUFACTURED TO CSA & ASTM STANDARDS • IPEX Ring-Tite°4' - 60" (100mm - 1,500mm) I 1 Pon X byaliaxis We build tough products for tough environments* R0 in -Tits 4" - 60" (100mm - 1,500mm) PERFORMANCE- PROVEN TOUGHNESS Ring-Tite°piping systems are SDR35 and SDR28 sewer pipes and fittings manufactured to demanding ASTM, BNQ and CSA standards. Ring-Tite joints can withstand well in excess of both the ASTM and CSA requirements. TIGHT JOINTS & CHEMICAL RESISTANCE LOWER TREATMENT COSTS PVC is virtually immune to chemical attack Eliminate infiltration and exfiltration.Ring-Tite's 50 psi capable from any type of sewage.Hydrogen Sulphide joints easily outperform concrete and corrugated PE joints. attack,which causes millions of dollars of damage to concrete and metal infrastructure, will not affect Ring-Tite. SUPERIOR FLOW CHARACTERISTICS Because of the smooth inside wall of Ring-Tite,a Manning's STRESS CRACK RESISTANCE coefficient of 0.009 can be used when designing systems using Ring-Tite pipe.This compares with Manning's While some HDPE pipes have been found coefficients of up to 0.023 for other materials like clay or to crack prematurely under load,Ring- concrete. Tite's tough PVC construction and superior formulation has been proven to be immune to these problems. ABRASION RESISTANCE Ring-Tite has been proven to be more abrasion resistant than SP 410 K other profile pipes,and has out-performed concrete pipe in CSA ASTM NQ 3624- testing at California State University. B182.2 F679 130/135 SAMPLE SPECIFICATION General Main line sewers will be PVC SDR35 sewer pipe and shall be in compliance with ASTM D3034 or ASTM F679 and third party certified to CSA B182.2.Sewer laterals will be PVC SDR28 sewer pipe and shall be third party certified by CSA as above. Joints Pipe Stiffness Fittings Sealing gaskets must meet the The minimum ring stiffness shall Injection-molded gasketed PVC fittings requirements of ASTM D3034 or ASTM be 320 kPa(46 psi)for SDR35 pipe shall meet the requirements of ASTM F679,CSA B182.2.In addition,the pipe and 625 kPa(90 psi)for SDR 28. 3034 and ASTM F1336 and shall be joints must be able to withstand a This stiffness will be determined certified to CSA B182.1 or CSA B182.2. minimum hydrostatic pressure of 345 kPa using the test methods Fabricated fittings must conform to (50 psi)without leakage. prescribed by ASTM D3034 and ASTM F1336 and CSA B182.2 ASTM F679. r Percent N Deflection of Ring-Tite (SDR 35 pipe) ManufacturedASTM Clean Sand& Sand&GravelEmbedment Granular Gravel with Fines Material . . Classification CLASS I IV JOINT TIGHTNESS Density •Ring-Tite pipe joints have been third AASHO party tested to withstand a 345 0 2,760 kPa(50 psi)hydrostatic pressure. 700 • • • • • • ••000) •• Injection molded fittings have also Height of Cover been laboratory tested to withstand m ft a 345 kPa(50 psi)pressure in an 1 3.3 0.3 0.5 1.0 1.0 1.7 2.1 undeflected straight alignment.This 2 6.6 0.4 0.5 1.0 1.0 1.8 2.2 does not mean that installations should be tested to these pressures 3 9.8 0.4 0.6 1.2 1.2 2.2 2.6 in the field,as these pressures could 4 13.1 0.6 0.8 1.6 1.6 2.9 3.5 damage manholes,laterals or 5 16.4 0.7 1.1 2.0 2.0 3.7 4.4 other appurtenances that are not 6 19.7 0.9 1.3 2.4 2.4 4.4 5.3 tested to the same standards as the 7 23.0 1.0 1.5 2.8 2.8 5.1 6.1 pipe and fittings.We recommend 8 26.3 1.2 1.7 3.2 3.2 5.9 7.0 the testing procedures outlined 9 29.5 1.3 1.9 3.6 3.6 6.6 7.9 in our Installation Guide,which is 10 32.8 1.4 2.1 4.0 4.0 7.3 8.8 available upon request or can be 1s 49.2 2.2 3.2 6.0 6.0 11.0 ' 13.1 downloaded from ipexna.com m Not Recommended Dimensions SDR35 SDR28 Min.Wall Min.Wall Thickness Thickness in MM in MM 4 100 3.97 100.94 0.12 3.06 4.21 107.06 3.91 99.42 0.15 3.82 4.21 107.06 .24 133.02 0.20 5.12 5.64 143.26 6 150 5.92 150.29 0.18 4.55 6.28 159.39 .83 148.01 0.22 5.69 6.28 159.39 8 200 7.92 201.16 0.24 6.10 8.40 213.36 - - - - - - 12 300 11.79 299.36 0.36 9.07 12.50 317.50 - - - - - - 15 375 14.43 366.42 0.44 11.10 15.30 388.62 - - - - - - 18 450 17.63 447.87 0.53 13.57 18.70 475.01 - - - - - - 21 525 20.79 527.99 0.63 16.00 22.05 559.99 - - - - - - 24 600 23.39 594.00 0.71 18.00 24.80 630.00 - - - - - - 27 675 26.36 669.42 0.80 20.29 27.95 710.00 - - - - - - 30 750 30.17 766.36 0.91 23.22 32.00 812.80 - - - - - - 36 900 36.11 917.22 1.09 27.79 38.30 972.80 - - - - - - 42 1,050 41.95 1,065.72 1.27 32.29 44.50 1,130.30 - - - - - - 48 1,200 47.89 1,216.56 1.45 36.87 50.79 1,290.30 - - - - - - 54 1,350 54.27 1,378.49 1.64 41.77 57.55 1,462.00 - - - - - - 60 1,500 58.08 1,475.48 1.76 44.71 61.61 1,564.90 - - - - - - Ring-Tite fittings are injection molded in most configurations up to 375mm(15")nominal diameter. Larger sizes are fabricated from sections of pipe. Westlake Pipe & Fittings ASTM D3034/I13 Gasketed Integral Bell PVC Gravity Sewer Pipe Certification ASTM D3034/I13 Gasketed Integral Bell PVC Gravity Sewer Pipe (sizes 4" through 15"; SDR 35, SDR 26, and SDR 23.5), provided by Westlake Pipe & Fittings, is manufactured in accordance with ASTM D3034. The PVC material conforms to a minimum cell classification of 12454 or 12364 as defined by ASTM D1784. The standard pipe laying length is 14 or 20 feet. Pipe supplied for gravity sewer applications is green in color. ASTM D3034 gasketed pipe products are offered in solid wall plain end, solid wall bell end, 2 row perforated bell end, and 3 row perforated bell end designs. All perforation holes are 1/2" in diameter, on 5" centers, and parallel to the axis of the pipe. The rows of the 2 row perforated design are spaced 120' apart. The rows of the 3 row perforated design are spaced 60' apart. Gasketed Integral Bell pipe products meet the requirements of ASTM D3212. Unless otherwise specified, all products are supplied with styrene-butadiene rubber (SBR) gaskets. Acrylonitrile butadiene rubber (NBR)and ethylene propylene diene monomer rubber(EPDM)gaskets are available as optional upgrades. All gasket material options meet the requirements of ASTM F477. These products provide a minimum pipe stiffness of 46 psi (SDR 35), 115 psi (SDR 26), or 153 psi (SDR 23.5)as defined by ASTM D2412. The following pipe products made at our Lodi, CA; Wichita Falls, TX; and Yucca, AZ plants are listed by IAPMO to be in compliance with the Uniform Plumbing Code (UPC°), International Plumbing Code (IPC®), and ASTM D3034: • SDR 35—4' 6", 8", 10", 12", 15" • SDR 26—4", 6", 8", 10", 12", 15" Certifications are based on the applicable edition of the referenced standard in effect on the date of manufacture. If we may be of further assistance, please contact Technical Services at tech nical(cbwestlakepipe.com. Sincerely ��>w4y-- Joshua E. Clapper Director, Product Marketing, Marketing and Development PI-CL-014 A02 . : ' Westlake Pipe & Fittings Reference Standards: • ASTM D1784 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds • ASTM D2412 Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading • ASTM D3034 Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings • ASTM D3212 Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals • ASTM F477 Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe PI-CL-014 A02 2 Christy's Detectable Marking Tape Our DETECTABLE marking tape provides for easy buried pipeline detection and below ground identification and warning.The tape can be located below ground with a non-ferrous metal detector when buried at the proper depths.All Christy's tape meets or exceeds the industry standards including the American Public Works Association (APWA) color code. TAPE MUST BE BURIED FLAT FOR MAXIMUM DETECTABILITY AND LINE PROTECTION. CONSULT YOUR SPECIFIC LOCATOR MANUFACTURER FOR BURIAL LIMITATIONS. BURIED ft 7611 611 -911 NOTE:Not all widths are available as standard7for the stock color/legend combinations shown.Contact Christy's'M for stock availability of specific 6" - 18"products.Non-stock combinations are subject to or wider 6" - 24" minimum requirements and plate charges. SPECIFICATIONS • Christy'ST" DETECTABLE marking tape consists of a 4.5 mil(0.005")thickness;five-ply composition;ultra-high molecular weight;100 percent virgin polyethylene;acid,alkaline and corrosion resistant. • The tape tensile strength is in accordance with ASTM D882-80A and will not be less than 7800 PSI. • Elongation properties are in accordance with ASTM D882-80A and are less than 150% at break point. • Tape color&legend combination will be in accordance with APWA or local requirements. The color is . The legend reads • Tape is 5 mil overall thickness,with a.35 mil solid aluminum foil core.A.8 mil clear film, reverse printed with a repeating warning message is laminated to aluminum foll with a 3.75 mil clear film backing. • Tape width shall be . (For best results we recommend a tape width at least 3/of the diameter of the pipeline being protected.A 4" diameter line would use 3" or wider tape for optimum protection). Standard widths are 2",3",6",&12". • Tape lettering shall be 1"tall on 2" detectable tape and 1.5"tall on 3"- 12"tape. SPECIAL AND CUSTOM LEGENDS Christy's'M offers a full range of non-standard tapes,including specialty applications such as Telem- T.Christy Enterprises,Inc. etry, Irrigation and additional water line wording.All standard combinations listed are available in 655 E.Ball Rd.•Anaheim,CA 92805 at least one color/width combination.We offer specific agency legends,designations or color com- Tel:(714)507-3300• Fax:(714)507-3310 binations.Custom legends can include the use of specific wording,insignias and phone numbers. www.TChristy.com•800-BLU-GLUE Call for special pricing. FEBUARY2021 UT-4031 How To Order Marking Tapes ICASTANDARD COLOR/LEGEND COMBINATIONS U VT11* fA.XX XX.X` XXX Example:TA.DT.2. is 2" Detectable Purple Reclaimed Water. Type of Tape Tape Colors Legend Code DT-Detectable 2-2" B-Blue E-Electric PW-Potable Water NO-Non-Detect- 3-3" P-Purple F-Fire RAW-Raw Water able 6-6" Y-Yellow FM-Force main RW-Reclaimed 12-12" G-Green FO-Fiber Optic Water R-Red G-Gas S-Sewer DETECTABLE&NON-DETECTABLE Orange IRR-Irrigation STDR-Storm Drain MARKING TAPE NPW-Non-Potable TEL-Telephone Water Service W-Water NOTE:Not all widths are available as standard for the stock color/legend combinations shown.Contact Christy's"for stock availability STANDARD COLOR/LEGEND COMBINATIONS of specific products.Non-stock combinations are subject to minimum requirements and _ plate charges. Blue IBIR "Caution Irrigation Line Buried Below"Blue W "Caution Non-Potable Water Line Buried Below" Blue BPW "Caution Potable Water Line Buried Below" Blue BRJ "Caution Restrained Joint Buried Below" Blue BRW "Caution Raw Water Buried Below" Blue BW "Caution Water Line Buried Below" Brown BRFM "Caution Force Main Buried Below" Green GFM "Caution Force Main Buried Below" Green GIRR "Caution Irrigation Line Buried Below" Green GNPW "Caution Non-Potable Line Buried Below" Green GPW "Caution Potable Line Buried Below" Green GS "Caution Sewer Line Buried Below" Orange OFO "Caution Fiber Optic Line Buried Below" Orange OTEL "Caution Telephone Line Buried Below" Purple PIRR "Caution Irrigation Line Buried Below" Purple PRW "Caution Recycled/Reclaimed Water Line Buried Below" Purple PNPW "Caution Non-Potable Line Buried Below" Red RE "Caution Electric Line Buried Below" Red RF "Caution Fire Line Buried Below" Yellow YE "Caution Electric Line Buried Below" T.Christy Enterprises,Inc. Yellow YG "Caution Gas Line Buried Below" 655 E.Ball Rd.•Anaheim,CA 92805 Yellow YPL "Caution Pipeline Buried Below" Tel:(714)507-3300• Fax:(714)507-3310 www.TChristy.com•800-BLU-GLUE FEBUARY2021 UT-4031 14A RiEo Marking Tapes DETECTABLE MARKING TAPES ORDERING INFORMATION 2"SO x 1000' BLUE Potable Water TA-DT-2-BPWTA 2"x 1000' BLUE Water Line TA-DT-2-BW r42"x 1000' GREEN Force Main TA BT 2 GFIVI BURIED�� � 2"x 1000' GREEN Sewer Line TA-DT-2-GS %MN BURIED 10r 2"x 1000' PURPLE Irrigation Line TA-DT-2-PIRR 2"x 1000' PURPLE Recycled/Reclaimed Water TA-DT-2-PRW DETECTABLE&NON-DETECTABLE 2"x 1000' RED Electrical Line TA-DT-2-RE MARKING TAPE 2"x 1000' YELLOW Gas Line TA-DT-2-YG 3"x 1000' BLUE Potable Water TA-DT-3-BPW NOTE:Not all widths are available as standard 3"x 1000' BLUE Water Line TA-DT-3-BW for the stock color/legend combinations shown. 3"x 1000' GREEN Force Main TA-DT-3-GFM Contact ChriSys-for stock availability of 3"x 1000' GREEN Irrigation Line TA-DT-3-GIRR specific products.Non-stock combinations are 3"x 1000' GREEN Raw Water TA-DT-3-GRW subject to minimum requirements and plate 3"x 1000' GREEN Sewer Line TA-DT-3-GS charges. 3"x 1000' GREEN Storm Drain TA-DT-3-GSTDR 3"x 1000' ORANGE Fiber Optic line TA-DT-3-OFO 3"x 1000' PURPLE Non-Potable Water Line TA-DT-3-PNPW 3"x 1000' PURPLE Recycled/Reclaimed Water TA-DT-3-PRW 3"x 1000' RED Electrical Line TA-DT-3-RE 3"x 1000' RED Fire Line TA-DT-3-RF 3"x 1000' YELLOW Non-Potable Water Line TA-DT-3-YCNPWL 3"x 1000' YELLOW Gas Line TA-DT-3-YG 6"x 1000' BLUE Irrigation Line TA-DT-6-BIRR 6"x 1000' BLUE Water Line TA-DT-6-BW 6"x 1000' GREEN Force Main TA-DT-6-GFM 6"x 1000' GREEN Sewer Line TA-DT-6-GS 6"x 1000' PURPLE Recycled/Reclaimed Water TA-DT-6-PRW 6"x 1000' RED Electrical Line TA-DT-6-RE 6"x 1000' RED Fire Line TA-DT-6-RF 6"x 1000' YELLOW Gas Line TA-DT-6-YG 12"x 1000' BLUE Water Line TA-DT-12-BWW 12"x 1000' GREEN Storm Drain TA-DT-I2-GSTDR 12"x 1000' GREEN Sewer Line TA-DT-12-GS 12"x 1000' PURPLE Recycled/Reclaimed Water TA-DT-12-PRW T.Christy Enterprises,Inc. 655 E.Ball Rd.•Anaheim,CA 92805 Tel:(714)507-3300• Fax:(714)507-3310 www.TChristy.com•800-BLU-GLUE *Custom options available.Call for details. FEBUARY2021 UT-4031 SPEC 87100 COPPER TRACER WIRE Color options ANFIEN 2 1 Image not to scale. See Table 1 for dimensions. CONSTRUCTION: • Soft drawn copper solid conductor • 16AWGto8AWG • Insulated with Linear Low Density Polyethylene (LLDPE) also known as high molecular weight polyethylene (HMWPE) • Color options: yellow, blue, red, orange, black, green APPLICATIONS AND FEATURES: • Used as tracer wire to locate buried conduit • 30 volt constructions suitable for direct burial • 30 or 600 volt depending on insulation thickness SPECIFICATIONS: • ASTM B3 Soft or Annealed Copper Wire 30 Volt CONDUCTORSIZE APPROX. 000' 16 0.0508 0.03 0.111 11 14 0.0641 0.03 0.124 16 12 0.0808 0.03 0.141 24 10 0.1019 0.03 0.162 36 8 0.128 0.03 0.189 56 600 Volt CONDUCTORSIZE APPROX. 000 16 0.0508 0.045 0.141 13 12 0.0808 0.045 0.171 27 8 0.128 0.045 0.219 60 (9) CABLETECH �t� Southwire ' ' • :�:.� IN Southwire Company,LLC I One Southwire Drive,Carrollton,GA 30119�www.southwire.com Services Copyright©2023 Southwire Company,LLC.All Rights Reserved UPDATED:Aug.18,2023,2:41 p.m.UTC REVISION:1.000.000 SPEC 87100 Color Options Fiber Optic Cable orange CATV/Telephone orange Gas yellow Conduit Colors black Electric regdo Sewer green O .:•� CABLETECH (h''•�/� Southwire ' ' • Southwire Company,LLC One Southwire Drive,Carrollton,GA 30119 I www.southwire.com "•` Services Copyright©2023 Southwire Company,LLC.All Rights Reserved UPDATED:Aug.18,2023,2:41 p.m.UTC REVISION:1.000.000 NOTE: CITY CALLS OUT TEES, PLANS CALLOUT WYES W/45s. 3.09 4.76 3.75 3.55 FOR REFERENCE ONLY DIMENSIONS SUBJECT TO CHANGE TITLE 8" x 6" TEE G x G x G pG30DM(�4� DaC�o D3034/F1336 SDR 35 PSM PVC v 1-800-437-4670 FARGO, ND DATE 10-05-13 SCALE NONE PART NO. 103-0086 , NOTE: CITY CALLS OUT TEES, PLANS CALLOUT WYES W/45s. 3.09 9.43 i i i 0.60 3.75 9.50 FOR REFERENCE ONLY DIMENSIONS SUBJECT TO CHANGE Q TITLE 8" x 6" WYE GxGxG D3034/F1336 SDR 35 PSM PVC pQODMC�4��,DaC�o 1-800-437-4670 FARGO, ND DATE 7-6-10 SCALE NONE PART N0, 107-0086 NOTE: CITY CALLS OUT TEES, PLANS CALLOUT WYES W/45s. 4.00 1.75 5.85 4.10 FOR REFERENCE ONLY DIMENSIONS SUBJECT TO CHANGE TITLE 6" x 45 DEGREE EL SxG FR@DMVj'om@.j D3034/F1336 SDR 35 PSM PVC 1-800-437-4670 FARGO, ND DATE 11-24-09 SCALE NONE PART NO, 122-0006 �M��J SDR35 D 3034 / PS46 F 679 FITTING SPECIFICATIONS 1.0 GPK PVC Sewer Fittings shall be manufactured in accordance with either ASTM D 3034, F1336 or F 679. The PVC material shall have a minimum cell classification of 12454, 13343 or 12364 as defined in ASTM D 1784. 2.0 The purpose of GPK in-line fittings is to convey municipal sanitary and industrial wastes,storm water runoff and many other related applications.They are designed to be used in gravity flow and low pressure applications not to exceed 10.8 psi. (74.5 kPa). 3.0 Injection Molded Fittings are produced in sizes 4" (100mm)through 12" (300mm)diameter. Fabricated Fittings are produced in sizes 4" (100mm)through 36"(973mm)diameter.A fabricated fitting is considered any fitting made from pipe or a combination of pipe and molded components. 4.0 Chemical Resistance GPK fittings resist attack from certain alcohols,alkalies, salt solutions,acids and other types of chemicals. Refer to chemical resistant chart for suitability. 5.0 Marking.GPK fittings shall be marked with applicable size, "PVC",company name or logo, PSM and the ASTM specification number(D 3034, F 1336 or F679).The fittings and/or packaging shall include the manufacturer's date and shlft code. 6.0 Testing.A test after installation of either low pressure air(Uni-B-6)or a water infiltration-exfiltration test is recommended. 7.0 Deflection Test.The maximum allowable pipe fitting deflection should be 7%%of base ID as shown in table X1.1 of D 3034, and X2.1 of F 679. 8.0 Backfilling and Tamping. Backfilling should follow closely after assembly of pipe and fittings. 8.1 Backfilling.with proper material is important to achieve desired density in haunching area which enables pipe,fitting and soil to work together to meet designed load requirements.This eliminates excess deflection and shear breaks due to heavy loads.Approved material shall be used properly,compacted continuously above and around the pipe and fittings as well as between fitting and trench wall.A cushion of approved material up to a minimum of 12" (305mm)over the fittings and between the trench walls shall be applied in accordance with the engineers'specifications. 8.2 Tamping.This shall be done by hand tamping of the embedment material between the trench wall of the service line fitting and riser connection.Tamping can also be done by mechanical tampers or by using water to consolidate the embedment material. Extreme unstable ground conditions may require wider trenches to enable you to compact a larger area around the pipe and fittings to the density consistent of the original ground surface conditions. 9.0 Service Lines. Normally,service lines from the property line to the collection sewer should be a minimum depth of 3 feet(1 meter)at the property line and should be laid in straight alignment and uniform slope of not less than%" per foot(20.8mm/meter)for 4" (100mm) nominal pipe and 1/8" (10.4mm/meter) per foot for 6" (150mm) pipe.Where collection sewers are deeper than 7 feet(2 meters)a vertical standpipe or stack is permitted but not recommended,consult the project engineer for proper installation details. Deep sewer chimney and risers necessitate extreme care during backfilling.Where surface loading is 1IPage 811 1pq,��J SDR35 D 3034 / PS46 F 679 FITTING SPECIFICATIONS anticipated the final backfill must be compacted to a density compatible with those surface loads to be encountered. 9.1 Backfilling around pipe service laterals on slope. Extra attention should be given on slopes to prevent the newly backfilled trench from becoming a "French Drain". Before backfilling completely there is a tendency for ground and surface water to follow the direction of the looser soil.This flow may wash out soil from under or around pipe and branch line fittings, reducing or eliminating the support needed.To avoid this problem the backfilling should be of greater compaction.Tamping should be done in 4" (100mm) layers and continued in this manner all the way up to the ground or surface line of the trench. Concrete collars or other concrete poured around the fitting to stabilize unwanted movement is recommended to prevent water from undercutting the underside of the pipe and fittings. Summary: Due to various ground conditions and different situations, installation techniques vary widely. We warranty our products to be free of manufacturer's defects.We will not replace the products that are installed or used incorrectly.The design of the systems that our product is used in is a factor that cannot be overlooked. Intro: GPK manufactures PVC sewer fittings in accordance with either ASTM D 3034, F 1336 or F 679 to be used in gravity flow or low pressure applications. Injection molded fittings are produced in sizes 4" (100mm)through 12" (300mm) diameter. Fabricated fittings are produced in sizes 4" (100mm)through 36" (973mm)diameter. Material: Fabricated fittings are manufactured from PVC pipe and molded components meeting the requirements of either ASTM D 3034, F 1336 or F 679 for workmanship,extrusion quality, stiffness, impact resistance,dimensions and structural performance. Extruded pipe components are made from PVC material with a minimum cell classification of 12454, 13343 or 12364 as defined in ASTM D1784. Injection molded fittings are made from PVC material with a minimum cell classification of 12454 or 13343 as defined in ASTM D 1784. Extrusion Quality: Extruded components are tested in accordance with and meet the requirements of ASTM D 2152 for properly fused PVC. Impact Resistance: Extruded Components are tested in accordance with ASTM D 2444 using a 20 lb (9.07kg).Tup A and a Flat Plate Holder B.The strength shall equal or exceed the values shown below: 4"—5" 150 Ft-Lbs 6"—8" 210 Ft-Lbs 10"—36" 220 Ft-Lbs (100mm—125mm 203 J) (150mm—200mm 284 J) (250mm—973mm 299 J) Impact Resistance: Injection molded fittings are tested in accordance with ASTM D 2444 using a 20 lb (9.07kg).Tup A and a Flat Plate Holder B.The strength shall equal or exceed the values shown below: 4"50 Ft-Lbs 6"—8" 75 Ft-Lbs 10"—12"90 Ft-Lbs (100mm 68 J) (150mm—200mm 102 J) (250mm—300mm 122 J) Pipe Stiffness: Extruded Components are tested in accordance with ASTM D 2412.The stiffness equals or exceeds the requirements of ASTM D 3034 and F 679. 2 1 P a g e 811 �MtF�4-AJ SDR35 D 3034 PS46 F 679 FITTING SPECIFICATIONS Pipe Flattening: Extruded components are flattened as described in ASTM D 3034 and F 679 until the distance between the plates is 40%of the outside diameter of the pipe.There shall be no splitting, cracking or breaking. Pressure/Pressure Deflection: Gasketed joints are tested in accordance with ASTM D 3212. Pressure: 10 minutes @ 10.8 psi (74.5 kPa)+10 minutes deflected @ 10.8 psi (74.5 kPa). Vacuum: 10 minutes @ 22 in. Hg(74 kPa)+ 10 minutes deflected @ 22 in. Hg (74kPa). Branch Bending: The chemically fused areas around the fabricated branches of tee,wye and tee-wye fittings are tested to ASTM F 1336 to verify their strength and integrity. Pipe Stop Support: Tee and tee-wye fittings are tested to requirements of ASTM F 1336 for pipe stop load support. No cracking or splitting shall occur and pipe spigot shall not protrude into waterway of the fitting. Joining Methods: Chemically Fused Solvent Weld Joints Solvent cement is handled and tested in accordance with ASTM D 2564 and D 2855.The Lap Shear Strength shall equal or exceed 900 psi (6205 kPa) @ 72 hours. Heat Fusion Welded Joints(Butt Fusion Welds) Elastomeric Seals(Gaskets) Must meet all requirements of ASTM F 477 and D 3212. Saddles: Injection Molded saddle tees and saddle wyes shall have skirts with a minimum of 80 square inches(516 square cm)surface area which can be bonded to pipe. Fabricated saddle tees and saddle wyes shall have skirts with a minimum of 160 square inches (1032 square cm)surface area which can be bonded to pipe. The worm drive saddle straps used to fasten the saddles are manufactured with corrosion resistant 300 series AISI stainless steel. GPK does not recommend gasket skirts where air tests are required. Epoxy Reinforced Welds. Threads: Threads shall be American National Standard Taper Pipe Threads (ANSI 131.20.1) which shall be gauged in accordance with ASTM Method D-2122. 3 1 P a g e 811 Twist-Tite Mechanical Plugs The Twist Mechanical Test Plug is designed for use in standard sized DWW piping for the purpose of blocking or testing of the system. An over-sized wing nut with a wrench pad makes installation easy. Manufactured of high impact ABS,with a steel plated screw,and a zinc nut,this product is rust and corrosion resistant. The sealing gasket is neoprene. End of Pipe Inside Pipe Pipe Use Range Maximum Back End of Pipe Pressure Minimum Maximum Nominal Bypass Water Shipping Product Pipe Pipe Air Units/ Size Size Head (p g) Model# Weight Code Diameter Diameter si Case (inches) (inches) (inches) (inches) (feet) (pounds) 1 1/2 83591 1.48 1.65 None 40 5 MWN 1 10 2 2 83592 1.90 2.17 None 40 5 MWN 2 10 2 3 83593 2.80 3.10 None 40 5 MWN 3 10 4 6 83596 5.77 6.08 None 30 5 MWN 6 5 8 Inside Pipe 4 83595 3.78 4.06 None 40 5 MWN 9 10 6 6 83597 5.77 6.08 None 30 5 MWN 10 5 8 8 83599 7.76 8.03 None 30 5 MWN 11 5 12 IPS CORPORATION Specifications subject to change without notice. RECESSED LIFT POCKET i 5/8" - 11 N.C. HD SCREW OCKET 3/4" LETTERS \ SS S. 1 1/4" LONG �(Do 01 1/2" x 2" RAISED PADS 14" 12 1/2" _ 1/4" 1 1/4"" 8„ 2" 11" 12 1/4" 14" NOTES: OLYMPIC FOUNDRY INC. 14-6255SET 11 " X 8" LOCKING CLEAN-OUT RING & SEWER COVER MATL: CAST IRON ASTM A48, CL30 RATING: H-20 IPART NO. M 1025 APPROX WT: RING-70 LBS, COVER-4-0 LBS. REV. A DATE: 7/16/03 NEW BORDER REV DOCUMENT APPROVED DWN: CL DATE: 07/16/03 �a REV. X DATE: XX/XX/XX DSC: A BY: DATE: xxxx i:a�io CHKD: CL DATE: 07/16/03 DWG #: M1025 SCALE: N/A SHEET: 1 OF 1 NOTE: M1025 SEWER CASTING ALTERNATIVE: v �o eo, ®® 0 IrT oo A MA 0077ED A li ��� UP CEO a� I � DRILL & TAP W/3/8" NC X 1-1/2" S.S. HEX HEAD CAP SCREWS 10 (180°, 2 PLCS) -81/2� 5/� 3 1/8 4 15 SECTION A-A NOTES: PARTS LIST ohs` OLYMPIC FOUNDRY INC. 1. MACHINE MATING SURFACES RING: 14-6126LT 2. STANDARD BLACK PAINT COVER: 14-6132LT TITLE M1007 LIGHTWEIGHT SEWER CLEAN OUT DRILL 3. SEE INDIVIDUAL DRAWINGS FOR FURTHER DIMENSIONS SET: 14-6132SETLT & TAP SET RATING: H-20 IPART NO. 14-6132SETLT MATL: CAST IRON ASTM A48, CL30 REV: B 10/14/2013 ADDED BOLT DIMENSIONS& UPDATED WT REV APX WT. 42 LBS. REV: B DOC APPVD DWN: EB 02/12/2008 TOLERANCES: REV: x.x =t .l x.xxx=t /1 �=tz' BY: DATE: CHKD: CM 02/12/08 14-6132SETLTM1007BODYSEWERCODT x.xx=f .os FRAC=t 16 DWG NO: SCALE: N/A I SH 1 OF 1