Loading...
HomeMy WebLinkAbout19700 67th Ave Ne Bldg A_P26-0035_2026 i FIRE ALARM PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: 0 New Installation ❑ System Modification ❑ Phased Installation Property Address. 19620 67th Ave NE Suite No.: Project Valuation: 35,000 Lot#: Parcel ID No.: 31051500101500 Preferred Contact: 71 Owner O Applicant 71 Contractor Project Description: new fully addressable fire alarm system w/voice evac. wire and installation of devices to be done by others. Approx 125 devices Owner Name: Snohomish County Public Works Phone No.: 425-388-3411 Email Address: eric.nordstrom@co.snohomish.wa.us Cell No.: Mailing Address: 3000 Rockefeller Ave city: Everett State: WA zip:98201 Applicant Name: Security Solutions NW Phone No.: 360-734-4940 Email Address: katies@ssnw.co Cell No.: 564-243-8526 Mailing Address: 1619 N State St cit :Bellingham State:WA zip:98225 Contractor Name: Same as applicant Phone No.: Email Address: Cell No.: Mailing Address: City: State: Zip: L&I Contractor License Number: S EC U RS N 770 M F Expiration Date: 7/6/2027 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: 0 Complete and Scaled Plans 0 Specification Sheets 0 Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ ✓❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $475 > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ = $ FACP/TRANSMITTER New $200.00 = $200 PERMIT FEE SUBTOTAL $675 PERMIT FEE TOTAL $675 PLAN REVIEW FEE $738.64 Processing/Technology Fee $25.00 TOTAL $1438.64 I hereby certify that I am the ❑ Owner, ❑Applicant, 0 Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Digitally signed by Katie Smith DN:O=Security Solutions NW,CN=Katie Smith,E=katies@ ■ Katie Smith Re son:l attest to the acwracy and integrity of this document Katie Smith 1/13/2 0 2 6 Location:Everett,WA Date:2026.01.13 15:13:13-08'00' Foxit PDF Edits,Version:2025.2.1 Signature Print Name Date REV2.2024 Page 2 of 2 Arlington Operations Center BILL OF MATERIAL 19620 67TH AVE NE QUANTITY MANUFACTURER PART NO DESCRIPTION MOUNTING BOX FIRE ALARM IV GENERAL NOTES ARLINGTON, WA, 98223 1 NOTIFIER NFS2-3030D FACU ASSEMBLY 72"TO TOP 1. INSTALL NEW ADDRESSABLE NOTIFIER 3030 FIRE PANEL W/ VOICE EVAC SYSTEM PER IFC 1 NOTIFIER AMPS-24 ADDRESSABLE POWER SUPPLY;120VAC 2021, NFPA 72 2019, NPFA 70 (NEC) 2023 REQUIREMENTS WITH WASHINGTON STATE 1 NOTIFIER SBB-B4 BACKBOX;2 CHASSIS;BLACK �s AMENDMENTS. b 1 NOTIFIER BP2-4 BATTERY DRESS PANEL Portage Creek Safeway 9 2 NOTIFIER BMP-1 BLANK MODULE DRESS PLATE 2. ALL WIRE IS TO BE INSTALLED IN EMT, EXCEPT SUITABLE CABLES RUN "OPEN" IN Wildlife Nutty Junkyard Grill © 1 NOTIFIER DR-B4 C SIZE DOOR W/WINDOWS;BLACK ACCESSIBLE LOCATIONS ABOVE CEILING OR WITHIN ATTIC SPACE. Reserve 1 NOTIFIER CPU2-3030D CPU FOR NFS2-3030 W/DISPLAY 3. CONDUIT IS TO BE PROVIDED AND INSTALLED BY OTHERS. i 1 NOTIFIER CA-1 CHASSIS,DVC,ONE ROW 4. CORE DRILLING REQUIRED TO FACILITATE ALL CONDUIT WORK. CORE DRILLED HOLES SHALL > 1 NOTIFIER CMIC-1 CHASSIS;PAGING MICROPHONE;WELL NOT PENETRATE THROUGH ANY STRUCTURAL BEAMS, REBAR AND/OR CONDUIT CONTAINED a 9 1 NOTIFIER DVC-EM DVC;EXTENDED MEMORY Reece Aggregates ^f, 1 NOTIFIER DVC-KD DVC;KEYPAD DISPLAY WITHIN THE CONCRETE SLABS AND/OR WALLS THAT MAY COMPROMISE THE STRUCTURAL and Recycling Q INTEGRITY OF THE BUILDING. CORE DRILL LOCATION MAY NEED TO BE ADJUSTED TO zo 1 NOTIFIER DPA-1 DRESS PLACE;DVC;ONE ROW • 1 NOTIFIER DP-DISP DRESS PLATE;DISPLAY;BLACK ACCOMMODATE OBSTRUCTIONS. PRIOR TO DRILLING COORDINATE EXACT LOCATIONS OF 2 NOTIFIER LCM-320 LOOP CONTROL MODULE HOLES WITH GENERAL CONTRACTOR. 1 NOTIFIER LEM-320 LOOP EXPANDER MODULE 5. THIS DRAWING SHOWS THE LAYOUT OF THE FIRE ALARM SYSTEM AND INDICATES THE F 1 NOTIFIER CHS-M3 MOUNTING CHASSIS APPROXIMATE LOCATION OF EQUIPMENT, WIRING, AND CONDUIT. WIRING AND CONDUIT ARE 1 NOTIFIER UDACT-2 UNIVERSAL DIGITAL COMM.TRANSMITTER SHOWN POINT TO POINT ONLY. THE CONDUIT IS TO BE INSTALLED IN APPROXIMATELY THE z z POWERSONIC PS-12400 12V,40AH BATTERY AREA AS INDICATED ON THE DRAWINGS; HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MODIFICATIONS AS MAY BE REQUIRED TO SUIT STRUCTURAL OR JOB NOTIFIER DAA2-5025ASSEMBLY AMPLIFIER ASSEMBLY 72"TO TOP SUPPLIED CONDITIONS. THE CONTRACTOR SHALL FURNISH ALL OFFSETS, ADDITIONAL MATERIAL, 3 120 VAC DIGITAL AUDIO AMPLIFIER(50 W,25VRMS),MAX CONDUIT ADJUSTMENTS, ETC. AS MAY BE REQUIRED TO MEET INSTALLATION CONDITIONS. 2 NOTIFIER DAA2-5025 ALARM CURRENT,4 SPEAKER CIRCUITS PER DEVICE EQUIPMENTBACKBOXWITHVENTILATEDLOCKING ACTUAL WIRE RUNS SHALL BE KEPT N AN ORGANIZED MANOR BY THE INSTALLING ByrnesPerfO+mini 1 NOTIFIER EQBB-64 DOOR,TWO TIERS,BLACK CONTRACTOR TO FACILITATE AS—BUILT DRAWINGS. Arts C ne 1 NOTIFIER EQDR-B4 DOOR ASSEMBLY,VENTED DOOR,TWO TIERS,BLACK 6. PRIOR TO ROUGH—IN COORDINATE THE EXACT LOCATIONS OF FIRE ALARM EQUIPMENT, 1 NOTIFIER NFS-LBB BATTERY BOX DEVICES, AND CONDUIT WITH THE ELECTRICAL, MECHANICAL, AND FIRE PROTECTION >_co 2 POWER SONIC PS-12330 12V,33 AH BATTERY CONTRACTORS. Z LOCAL OPERATING CONSOLE 7. THE CONTRACTOR IS TO REVIEW AND VERIFY ALL FIELD CONDITIONS, MEASUREMENTS, PLANS, NOTIFIER LCD- -4B ANUNCIATORDRESSPANEL SOLUTIONS M-1 REMOTE LOCAL 5a°ToTOP SUPPLIED STOCK NW WILL NOT ASSUME THE RESPONSIBILITY OF THE K PRIOR NOSU ORDERING, FABRICATION, ILITY AND INSTALLING. VICINITY MAP 1 NOTIFIER ADP ALARM COMPONENTS OR 1 NOTIFIER DP-DISP I DRESS PANEL CONDUIT FITTING PER PLAN. N o 0 NTS: 1 NOTIFIER DR-AA4 DOOR ASSEMBLY,WINDOW,ONE TIER,BLACK 8. THE FIRE ALARM SYSTEM CONTRACTOR AND GENERAL CONTRACTOR SHALL COORDINATE ALL H w o N 1 NOTIFIER LCD-160 TERMINAL AND ACS MODE,BACKLIT LCD DISPLAY GUTTING, PATCHING, AND FINISH WORK. ¢¢v O1 FIRE ALARM SYSTEM 1 NOTIFIER RM-1 REMOTE MICROPHONE O 9. ALL ALARM WIRING IS TO BE IN ACCORDANCE WITH NFPA 72 D a 1 NOTIFIER SBB-AA4 BACKBOX ASSEMBLY,ONE TIER,BLACK V ¢^1O 10. WIRING PATHWAY CLASS DESIGNATIONS: J z x o 0 ATOR — STAIRWELL AND ELECTRICAL RISERS TO BE CLASS B W O z m M 1 HONEYWELL HWF2V-COM CELLULAR COMMUNICATOR AS REQUIRED SUPPLIED — NAC PATHWAY CLASS DESIGNATIONS: CLASS B DEVICE LEGEND 1 POWERSONIC PS-1270 12V,7AH BATTERY �m SYMBOL MANUFACTURER PARTNO DESCRIPTION Wli — SLC PATHWAY CLASS DESIGNATIONS: CLASS B tin FA_.P­j NOTIFIER DAA2-5025ASSEMBLY AMPLIFIER ASSEMBLY WITH 1X DAA2-5025 1 POTTER PSN-106 10ACONVENTIONAL POWER SUPPLY WTH6OUTPUTS 72 TO TOP SUPPLIED 11. PENETRATIONS THROUGH FIRE RATED PARTITIONS TO BE SEALED BY OTHERS TO MAINTAIN 2 POWER SONIC PS-1270 12V,7AH BATTERY THE INTEGRITY OF THE PARTITION. INTELLIGENT NON-RELAY PHOTOELECTRIC DEVICES 12. MOUNT PULL STATIONS WITHIN 60" OF THE LATCH SIDE OF THE EXIT DOORWAY AND NOTIFIER DNRWIFSP-951R DUCT DETECTOR/FSP-951R.FLASHSCAN AND CLIP MODE 2 NOTIFIER DNRW/FSP-951R INTELLIGENT NON-RELAY PHOTOELECTRIC DUCT AS REQUIRED SUPPLIED BETWEEN 42" AND 48" ABOVE FLOOR LEVEL. ALL DEVICES SHALL BE MOUNTED AT THE AODRESSABLECONTROL MODULE W1 DETECTOR/FSP-951R.FLASHSCAN AND CLIP MODE. SAME HEIGHT. ©M NOTIFIER FCM-1 FLA$H$CAN,1CL455AOR1 CLASS B 2 NOTIFIER FCM-1 ADDRESSABLELASSOL 1CLASODULE W/FLASHSCAN,1 AS REQUIRED 4-SQUARE BOX 13. LOCATE SMOKE AND HEAT DETECTORS NOT CLOSER THAN 36" FROM AIR—SUPPLY DIFFUSER CLASS A OR 1 CLASS B DM NOTIFIER FDM-1 ADDRESSABLE DUAL MONITOR MODULEW/ ADDRESSABLE DUAL MONITOR MODULE W/FLASHSCAN, OR RETURN—AIR OPENINGS. FLASHSCAN,2 CLASS B 11 NOTIFIER FDM-1 2 CLASS B AS REQUIRED 4-SQUARE BOX 14. LOCATE DETECTORS NOT CLOSER THAN 12" FROM ANY PART OF A LIGHTING FIXTURE AND ADDRESSABLE MONITOR MODULE WI ADDRESSABLE MONITOR MODULE W/FLASHSCAN, 0 NOTIFIER FMM-1 FLASHSCAN,SUPERVISESCLASSACE NOT DIRECTLY ABOVE PENDANT MOUNTED OR INDIRECT LIGHTING. CLASS BOF DRY CONTACT INPUT 1 NOTIFIER FMM-1 SUPERVISES CLASS A OR CLASS B OF DRY CONTACT AS REQUIRED 4-SQUARE BOX INPUT 15. INSTALL A COVER ON EACH SMOKE DETECTOR THAT IS NOT PLACED IN SERVICE DURING O NOTIFIER FMM-101 ADDRESSABLE MINI MONITOR MODULE 6 NOTIFIER FRM-1 ADDRESSABLE RELAY MODULE W/FLASHSCAN,2 AS REQUIRED 4-SQUARE BOX CONSTRUCTION. COVER SHALL REMAIN IN PLACE EXCEPT DURING SYSTEM TESTING. FORM-C DRY CONTACTS 16. AUDIBLE/VISUAL ALARM INDICATION DEVICES SHALL BE INSTALLED NOT LESS THAN 6" RM NOTIFIER FRM-1 ADDRESSABLE RELAY MODULEW/ 1 NOTIFIER FMM-101 ADDRESSABLE MINI MONITOR MODULE FLASHSCAN,2 FORM-C DRY CONTACTS ADDRESSABLE LOW-PROFILE PHOTOELECTRIC SMOKE BELOW THE CEILING BETWEEN 80" AND 96" ABOVE FLOOR LEVEL. INSTALL HORN/STROBES ADDRESSABLE LOW-PROFILE 5 NOTIFIER FSP-951 W/B300-6 DETECTOR.FLASHSCAN ONLY. CEILING 3-ROUND BOX ON FLUSH MOUNTED BACK BOXES. ALL DEVICES SHALL BE MOUNTED AT THE SAME HEIGHT. DRAWING REVIEWED BY: OS NOTIFIER FSP-957 WIB300d PHOTOELFLASHsc NON DETECTOR. 17. AUDIBLE ALARM INDICATION DEVICES SHALL BE INSTALLED NOT LESS THAN 90" ABOVE THE CHRISRUSSELL 1 NOTIFIER FST-951R W/6300-6 LOW-PROFILE,INTELLIGENT,RATE-OF-RISE THERMAL CEILING 3-ROUND BOX SENSOR.FLASHSCAN ONLY. N¢Er c6RnNvnoN No.I zoszo OH NOTIFIER FST-951RWIB300-6 LOW-PROFILE,INTELLIGENT RATE-OF- 2 NOTIFIER ISO-X SLC LOOP ISOLATOR MODULE AS REQUIRED 4-SQUARE BOX FLOOR AND NOT LESS THAN 6" BELOW THE CEILING. ALL DEVICES SHALL BE MOUNTED AT FIRE ALARM SYSTEMS-LEVEL III THERMAL SENSOR.FLASHSCAN ONLY.Y. THE SAME HEIGHT. CERTIFICATION EXPIRES:09.01.28 9 NOTIFIER NBG-12LX DUAL-ACTION ADDRESSABLE PULL STATION.INCLUDES 48"TO CENTER 1-GANG BOX ® NOTIFIER ISO-X SLC LOOP ISOLATOR MODULE KEY LOCKING FEATURE. 18. MOUNT REMOTE ANNUNCIATOR AT 54" ABOVE FLOOR LEVEL. 1 NOTIFIER NBG-12L0B DUAL ACTION LEXAN STATION,OUTDOOR 48"TO CENTER 1-GANG BOX 19. CONTRACTOR SHALL PERFORM AND MEET ALL CODE REQUIRED TESTS, AND FILE A REMOTE LOCAL OPERATOR CONSOLE APPLICATIONS Loc NOTIFIER LCD-160w/RM-1 MATERIALS TEST CERTIFICATE PER NFPA 72. ASSEMBLY-CONFIGURATION 2204754 1 POTTER RTS-0 NORMALLY OPEN ROOM TEMPERATURE SWITCH AS REQUIRED 1-GANG BOX DUAL ACTION LEXAN STATION,OUTDOOR 2 SYSTEM SENSOR 5623 135°F(57°C)FIXED TEMPERATURE,DUAL CIRCUIT. CEILING 3-ROUND BOX 20. ADD ELECTIVE MANUAL PULL STATIONS AT ALL EXTERIOR EXIT DISCHARGE NOT REQUIRED ❑F NOTIFIER NBG-12LOB APPLICATIONS 1 SYSTEM SENSOR SCWLED STROBE,CEILING,WHITE CEILING 4-SQUARE BOX BY THE IFC 907.2 TO ACHIEVE THE SPECIFIC SAFETY OBJECTIVE OF OCCUPANT FF DUAL-ACTION ADDRESSABLE PULL 1 SYSTEM SENSOR SPCWL 2-WIRE,SPEAKER WHITE CEILING CEILING 4-SQUARE NOTIFICATION BY STAFF PER NFPA 72 7.2.1, 17.15, & 23.3.2. NOTIFIER NBG12X STATION.INCLUDES KEY LOCKING OUTDOOR SPEAKER STROBE STANDARD CD CEILING 21. ADD ELECTIVE OCCUPANT NOTIFICATION IN STORAGE & MECHANICAL AREAS ACCESSIBLE , , , FEATURE. 3 SYSTEM SENSOR SPSCWKLED CEILING SBBCWL FIRE ALARM CONTROL UNIT, LED ONLY BY MAINTENANCE AND SERVICE PERSONAL NOT REQUIRED BY AFC 907.2 & 907.5 FACU NOTIFIER NFS2330AOD(BASE) ADDRESSABLE[BASE] 33 SYSTEM SENSOR SPSCWLED 2-WIRE,SPEAKER STROBE LED WHITE CEILING CEILING 4-SQUARE BOX TO ACHIEVE THE SPECIFIC SAFETY OBJECTIVE OF OCCUPANT EVACUATION PER NFPA 72 af 6 SYSTEM SENSOR SPSWKLED OUTDOOR SPEAKER STROBE,STANDARD CD,LED 80"TO CENTER SBBSPWL W NAC POTTER PSN-106 IDACONVENTI 6NAALPOWERSUPPLY WITH 27 SYSTEM SENSOR SPSWLED 2-WIRE,SPEAKER STROBE LED WHITE WALL 80"TO CENTER 4-SQUARE BOX 7.2.1, 1 8.1.6, 18.1.7, 1 8.5, & 23.3.2. 22. ANY DEVIATION FROM THE APPROVED PLANS BY THE INSTALLING CONTRACTOR MUST BE Z POTTER RTs-o NORMALLYOPENROOMTEMPERATURE 1 SYSTEM SENSOR SPWL 2-WIRE,SPEAKER WHITE WALL 80"TO CENTER 4-SQUARE BOX REVIEWED AND APPROVED BY THE SSNW DESIGN ENGINEERING TEAM PRIOR TO MAKING THE LLJ U LT RT SWITCH 2 SYSTEM SENSOR RTS151 REMOTE TEST SWITCH AS REQUIRED 1-GANG BOX 1 SYSTEM SENSOR SSM24-10 ALARM BELL 10"24VDC,RED SURFACE SUPPLIED(SA-WBB) PROPOSED CHANGE. OH SYSTEM SENSOR 5823 135 7(5T°C)FIXED TEMPERATURE,DUAL l/1 CIRCUIT. 2 NOTIFER DST1 DUCT DETECTOR SAMPLING TUBE AS REQUIRED BUILDING NOTES: Cityof Arlington co Z 1 SPACE AGE SS000626 DOCUMENT STORAGE BOX 72:TO TOP SUPPLIED g O SYSTEM SENSOR SCWLED STROBE,CEILING,WHITE 'WIRELESS COMMUNICATOR SUBJECT TO CHANGE BASED ON MONITORING CONTRACT AND ON-SITE CONNECTIVITY. AHJ:CITY OF ARLINGTON Building Department � ® LU SYSTEM SENSOR SPCWL 2-WIRE,SPEAKER WHITE CEILING OCCUPANCY TYPE: APPROVED L1J Z CA Q A-3(ROLL CALL&CONFERENCE) Kevin Olander-02/18/2026 I— QQ LLi f"( SYSTEM SENSOR SPSCWKLED OUTDOOR SPEAKER STROBE,STANDARD - B(BUSINESS) V) \ S C,WP CD,CEILING,LED CONSTRUCTION TYPE:VB No changes authorized unless approved by V) Q O S SYSTEM SENSOR SPSCWLED 2-WIRE,SPEAKER$TROBE LED WHIM the Building Official Z CEILING SPRINKLED:YES g = Z OUTDOOR SPEAKER STROBE,STANDARD SYSTEM SENSOR SPSWKLED CD,LED CODES: $ ti o � wP 2021 IBC cfl ( U SYSTEM SENSOR SPSWLED 2-WIRE,SPEAKER STE BELEDWHITE WALL 2021 IFC W Q z ) Z Z NFPA 70 2023 SHEET INDEX Ce w J b J ® SYSTEM SENSOR SPW'L 2-WIRE,SPEAKER WHITE WALL SHEET DESCRIPTION N �_ w NFPA 72 2019 0 o CABLE LEGEND FA.0.01 SHEET INDEX,SYMBOL LIST,BOM,ETC... LL d Q d Q SYSTEM SENSOR SSM24.10 ALARM BELL 10-24VDC,RED CIRCUIT WIRING FA.1.01 RISER DIAGRAM SIZE:ARCH 2 36 SOURCE CIRCUIT CIRCUIT TYPE TAG STYLE SYMBOL TYPE DESCRIPTION AN/G LENGTH FA.1.02 PAGING ZONES DRAWN BY:ANDREW OLIVER FACU DAL DIGITAL AUDIO LOOP L CLASS B FIRE ALARM 162 FPLR WEST PENN D980 RED #16 12V-0' RTS SYSTEM SENSOR RT5157 REMOTE TEST SWITCH FACU RDP BUS POWERISERIAL P CLASS FIRE ALARM 1614 SOL JKT FPLRIMRLRED #16 12V-0" FA.1.03 ADS MAP NAC SIG NOTIFICATION V CLASS FIRE ALARM 142 SOL JKT FPLP I RL RED #14 150'-0' DATE: FA.2.01 SITE PLAN DATE :1z/o4/zozs NAC AUX AUXILIARY POWER A CLASS B FIRE ALARM 142 SOL JKT FPLP I M RL RED #14 150'-0' FA.2.02 LOWER FLOOR PLAN REV DATE: AMP SPK AUDIO S CLASS FIRE ALARM 162 SOL JKT FPLP I M RL RED,SHIELDED #16 100'-0' FA.2.03 UPPER FLOOR PLAN BUSINESS UCENSE# NAC SIG NOTIFICATION 142 SOL JKT FPLR iM RL RED #14 SKURSN790NE AMP SPK AUDIO T CLASSB FIRE ALARM 162 SOL JKT FPLR I M RL RED,SHIELDED #16 2200'-0' FA.3.01 DEVICE WIRING DETAILS,MATRIX,AND VOICE EVAC MSG ELECTRICAL LICENSE# FACU SLC SIGNALING LINE U CLASS FIRE ALARM 162 SOL JKT FPLR I M RL RED #16 1250'-0" FA.4.01 BATTERY CALCULATIONS SECURSN954JG FACU ADC INDICATING Z CLASS B FIRE ALARM 162 SOL JKT FPLR lM RL RED 2 1,"' FAA.02 BATTERY CALCULATIONS CONT. FACU IDC TEST SWITCH B CLASS FIREALARM 1616SOLJKTFPLRIMRLRED #16 50w' FAA.03 BATTERY CALCULATIONS CONT. FA.0.01 CABLE LEGEND _ SOURCE CIRCUIT CIRCUIT TYPE CIRCUIT WIRING TAG STYLE SYMBOL TYPE DESCRIPTION AWG LENGTH FACU DAL DIGITAL AUDIO LOOP L CLASS B FIRE ALARM 1612 FPLR WEST PENN D980 RED #16 120'-0' FACU RDP BUS POWERISERIAL P CLASS B FIRE ALARM 16/4 SOL JKT FPLR 1 M RL RED #16 120'-0' MAC SIG NOTIFICATION V CLASS FIREALARM 14/2 SOL JKT FPLP 1M RL RED #14 150'-0' NAC AUX AUXILIARY POWER A CLASS FIREALARM 1412 SOL JKT FPLP 1M RL RED #14 150'-0' AMP SPK AUDIO S CLASS FIRE ALARM 1612 SOL JKT FPLP 1M RL RED,SHIELDED #16 100'-0' NAC SIG NOTIFICATION 14/2 SOL JKT FPLR I M RL RED #14 AMP SPK AUDIO T CLASS FIRE ALARM 1612 SOL JKT FPLR I M RL RED,SHIELDED #14 2200'-0' FACU SLC SIGNALING LINE U CLASS FIRE ALARM 16/2 SOL JKT FPLR I M RL RED #16 1250'-0" FACU EC INDICATING Z ES SB FIRE ALARM 1- OL JKT FPLR I M RL RED #16 FACU IDC TEST SWITCH B CLASS B FIRE ALARM 16/6 SOL JKT FPLR I M RL RED #16 o >a t `} s z �M1OF CD A� o y" 11 s LOCATED IN VESTIBULE 201 ¢3 v rn CY LOCAL OPERATOR = N M a �h~ CONSOLE UR v W j sLn C. m 7 NM1O�� N� NM1N N� \N0 \N0 NN1 \Np NNS NNA NN0 \NM1 NNN NNO NA0 \ \p1 N \ N� \ NA1 P NqN S �9�0. �S- QM1S- �S- QM1S- �S- �S- QM1S- �S- �S- QM1S- QM1S- QM1S- �,S- p15 QM1S �S �S QM1S 0S QM1S �S �;S PV'*iS'�A P j.'IV. PN M1\ P�jM1p P yq9 P ,�0 P N1 P q6 P 10 P \A P q9 P qb P qo P \�0A PTIp;SAg Pl1',�0 PlA,�1 P� P�,ypO P23��A,,A�p P�',S�A�,,9�� P�,yp4 P�,SA1 V A-0 N`Y�� 1�� NS`�� N0�0v 15�y6 1�yP N0'"S� N0`'a�y N�� N0�0u• NS`��y N�� N�� N'r'"� N�'� N�� 1�5� NO�Sut N.�� "1w1� 'N'"M1�3 1�yN 1�yp � $ � 41N- 0 0 0 0 0 0 0 0 0 0 0 NEO\' P SP P P P P SP P SP P P SP ("� -�N- 4 — NV� AM1-'01 _ - FROM FACP H e ��SM1 Z p09 OAN��FPL M1gN - µNM4 O'-1 00 \1� pJ\ N�1 µ��"I O F S MM S UPPER FLOOR �QM1�M1AN pM1h P - W'eM1 DRAWING REVIEWED BY: 7 I AMPLIFIERPANEL CHRIS RUSSELL —�— ,SS.. NIREALA CERTIFICATION RM EMS N0 EL III 0 L_ gM1A\��PFPCM1 p0 N F°�p00�PQ p0 OV��NVOS°W 14�ST 10 1 1P�G1S CERTIFICATION EXPIRES:09.01..28 dY d.Y' 0'17- pM19 \-1F0.P\I pM10 p'k0 di1 \-11Kz�(P lzp. �FJA \.ax. �,�. F\s� �,�N� \.NON' \9`�' any o�` H S F F RM F DM DM DM DM RM RM L Z Al.AM Z 3 3 p'\" °\.0 pNs"� pNS%9' pNS pN' N AMPLIFIER PANEL ON LIM:026.Z01-I EOL47k _1 M:034-M:035-Z02-7 EOL 47k LT FITS RTS P�'ypOE PV',ypA WRSA9 Plb,'AM1 P100p1 FIT N o N, N o _ SI �� 1ryN'L _ FT �3m.��o' �yQ 0P\\V S�\'k(\<J 0µJt`�` l e E SNµ QM1,ryM1N QM1p M10 PTNQ N9,EN9 ow Ve N0ry10 NM1e NSM111 i NM1e NSM1-NS i'y",y8 M1N3�13 i"N"W `I'N5111 M1N�ry10 `I'�S'M1A°'ON' NM1eA9M1A1 M1 M1S{ oo,,pO IN,-,AAA PNM1N- NE,,- PN'LASM1AN V - oL FP0'V�'3�0P'C��y°NN''��\OG\�E�e00J0 P°SpPN�µ .10 µ �\GIN US'��1 Nti Nti Nti NA'L' ro 1YJ\ Nc N0� N07V N0� 0 1575 p1 157Y 0'i? 1S7\ NOc� N0� N0c N 1YJ\ 1501 Nc NYA Nc� - S FIRE ALARM xAcPOPCP1p0 AN SEy Gay �$ .01 L\. p$'� pM1 0 pyS'A .INN 'i�'A G M1 5, 1d G M1 p1S+ 0 M1NS M1HN - .. 5W gN Op`L QO V d p00" EP pNp �M 1M1 EP 13 `cQ' 1A` S J-I- p 1 Lay Q�N9 \4 P Z 0 0 0 0 0 0 0 pM1 OM1 pM1 OM1 p1 CONTROL PANEL 41A. 11F. NNj;. P� 11A. Sy 1QF. LO NM;. L°NNN. L\' 1QF. P- NNp. y lf;. NP. 11F. \'P 11P '� .�S P S S SP SP SP SP SP SP P P SP SP P SP SP SP��— - - - \4�" \,N°� ���µ - F S DM DM DM DM DM RM CM DM CM S RM RM RM DM U QNSNO;,SNµ 2NSN10 pNSN.NO pNEN-NA QNSN-N0 QNSN IM1 QNSN.NN QNSN,NO QNSNAO QNSNpO QNSNp1 QNSNA°` PNSS` QNSINA�' FN$IAS FNS\ QNSN JISLAN o—V :-^--C):.�. • A.V 4--Z(2) Z M Z a�N0 N1 P�NO P�NS P�NA P�NS PM NM1 NN PT NO PN PN PV 1 P� PT P� PTA P�M1 A (J H LIM:020.M:027-Z02-7 EOL47k O NN. NN, NN. 11N- NN• l\N. NNSH NNAO aNA NNsu NNAO NNAA N,A'! NNA N _ CV ry N5�0,6 NO NO yN�S�_y y�N5�0,6 ryy# NYC 30.6 NS N` N5�0,N NSA N'��� N'� N' y'NN�A.A S TEL lELfl2 P P Y1,( )✓( �'M1r� P 0 0 P 0 �`Y�°a M1 pSP pM1O NJ.�1'-'.( }_(N'Y'- I HW2VF L W � ~ CELL LLI Z L al I NACE%PANDER \\ Q LL.I v POWER SUPPLY --- ---_--_— _-- ---- -- J l} / O — ——— ———— ——— ———— ——— -------- j Q O S LOWER FLOOR w Q o O Z Z PANELS LOCATED IN MDF 105 r LLI G 0 J w J City of Arlington a , Q ° Q Building Department SIZE:ARCHD 24x36 APPROVED DRAWN BY:ANDREW OUVER Kevin Olander- 02/18/2026 DATE DRAWN I2/04/2025 REV DATE: No changes authorized unless approved by BUSINESS LICENSE# RISER DIAGRAM the Building Official SECUALLCENNE ELECTRICAL LICENSE# SEC URSN954JG FA.1.01 PAGING ZONES ZONE LOCATIONS CIRCUITS 1 FIRST FLOOR AMP1-S1, S2, S3 2 SECOND FLOOR AMP2-S1, S4 3 STAIRS AMP2-S2 4 SECOND FLOOR ELEVATOR I AMP2-S3 o n t E FIRST FLOOR SECOND FLOOR ELEV. ELEV EOU P, EMERGENCY IISTAIRS _ ® EUPPEES ms] IGDoP1 0 o L 0 0I VESTOBULE \/ 1E — ry I I K u QA Uj u R,oTTE �3a MESOMERELW W rn 7 RHV eoONi coOR ®®®®®® e,o ®u Aa®®®® ®®®® lu `~^Q n U, J Z=o 6 R6T AmAE MENs U m m F ooGs oToRM. o REo M oA` p e w J u W TORAG ,vu ceuxc ®®®®®® ®®®®®®® ®®®® � C] WATER r� c -- -- o Bos so` O O 0 s OO ELEG oR �oRGrvs O UAL 0 � ] O o hTEO w,ININGEA ING - _ WOM �aa rEIN�N �` Lo ROoLL ® ❑o❑ --_ o RED ❑ O D s s -- �cENry O O TIONB _-_ E❑ C] Cl C� O WOMEN ❑o❑ DRAINA T. MoR Ro C] Cl CC REo M MoNF I a ,a � FT r071 oO DP voR� 71LA 0 0 0 oElLrvo WoRR 0 DRAWING REVIEWED BY: CHRIS RUSSELL LRY NGft NICET CERTIFICATION NO.120520 'ESTIBUL 0 OL 'n'o r,�IUI+V FIRE ALARM SYSTEMS-LEVEL III ]�R RVISORO iss , u a O5CERTIFICATION EXPIRES'09.01.28 W a o [Iury a cEI cE1u cEi w OPERATIONS CENTER-LEVEL 1 1-- Z w U V) OPERATIONS CENTER-LEVEL 2 N O CV w W rn Q OPERATIONS CENTER-STAIRS w Q w Ln Q O Z Z 2 O OPERATIONS CENTER-ELEVATOR Q o o J co (D- w Q s o Z_ � z_ w G � J G City of Arlington " Li a Q ° Q Building Department SIZE:ARCHD 24x36 APPROVED DRAWN BY:ANDREW OUVER Kevin Olander-02/18/2026 DATE DRAWN:12/04/2025 REV DATE: No changes authorized unless approved by BUSINESS LICENSE# PAGING ZONES the Building Official SECURSN7 ELECTRICAL LICENSEENSE # SECURSN954JC SCALE:NTS FA.1.02 PAGING ZONES INTELLIGIBILITY WILL BE TESTED PER ANNEX D GUIDE LINES WITH A HAND HELD INTELLIGIBILITY MICROPHONE TO FIELD TEST THIS SYSTEM.WHERE POSSIBLE ANNEX D GUIDELINES OF A MINIMUM 90 PERCENT OF MEASUREMENT LOCATIONS HAVING A MEASURED STI OF NOT LESS THAN 0.45(0.65 CIS)AND AN AVERAGE STI OF NOT LESS THAN 0.50(0.70 CIS)WILL BE ZONE LOCATIONS CIRCUITS FOLLOWED. IF ANNEX D GUIDELINES CANNOT BE MEET DUE TO AMBIENT CONDITIONS WE WILL WORK WITH THE FIRE 1 FIRST FLOOR AMP1-S1, S2, S3 MARSHAL'S OFFICE TO DETERMINE INTELLIGIBILITY PER 18.4.11 WITHOUT QUANTIFIABLE MEASUREMENTS.WHERE INTELLIGIBILITY MAY BE IMPOSSIBLE DUE TO AMBIENT CONDITIONS WE WILL WORK WITH THE FIRE MARSHAL'S OFFICE AND 2 SECOND FLOOR AMP2-S1, S4 THE OWNER TO DEVELOP AN APPROVED EMERGENCY RESPONSE PLAN THAT INCLUDES ALLOWING OCCUPANTS TO MOVE 3 STAIRS AMP2-S2 AWAY FROM MECHANICAL OR PRODUCTION EQUIPMENT UPON ACTIVATION TO AN AREA WHERE INTELLIGIBILITY CAN BE OBTAINED(EXAMPLE:ALLOW OCCUPANTS TO MOVE UP TO 33'IN REGULARLY OCCUPIED AREAS AND UP TO 50'IN 4 SECOND FLOOR ELEVATOR AMP2-S3 TYPICALLY UNOCCUPIED AREAS.) t C, FIRST FLOOR SECOND FLOOR GDR ERGEN SIcooP1B,UE / N rARs E io upoLE 0 0 0 0 A R N w o o RITCHENErre F Q El" Al oM °EUCOIL, T R B N3v v o J zxoo O u m m GDIAL W o 0 z RBTAo o MEN•B �oR oA 'n ^m woes t7E o REoM ®®®®®® ®®®®®®® ®®®® V,to o eos of � CA „< o CO R TN. � O O TD �� wDM - - G� RG ❑a❑ - - RE OM c�RA H NGIPAV RooLL00 D INERATIONs - ® ClO ClO ❑®❑ P PA MENTI MANAGER O O o c ,o-0EL. sroE WOMEN sMULoGONF -_-_ ❑ O D o �L-- LJ REoM WD DRANAAD WO R LEAD WOR RCD LOCoO �E, �O,l� 0 ,< s. O oaE,H� o WABHOFF 0 DRAWING REVIEWED BY: 0 CHRIS RUSSELL c - O 0 RYNG NICET CERTIFICATION N0VELIII 0 WOP FIRE ALARM SYSTEMS�LEVEL III LJ OL ,00 cEaw CERTFICATION EXPIRES.00.01.28 0 oR °N ox „< , �N s W AUDIBILITY REQUIRED H Z W U Ln VOICE INTELLIGIBILITY REQUIRED co Z C\l O L W � Q W Z c/1 W Q LV Ln Q O � 2 Z Z oC ol- 0 00 J 1 � V Q o Z Z W uCNO J � -j City of Arlington N a Q Q Building Department SIZE,ARCH 24.36 APPROVED DRAWN BY:ANDREW OLIVER Kevin Olander-02/18/2026 DATE DRAWN 12/04/2,— REV DATE: No changes authorized unless approved by BUSINESS LICENSE# the Building Official SECURSN790NE ADS MAP ELECTRICAL LICENSE# SECURSN954JC SCALE:NTS FA.1.03 X o ° z . . ° t .a o a. E g z FP FP FP x CD N o 2J. - �A ^w C. m LoI I I I I I SD I SD V) ° I I I Q ° DRAWING REVIEWED BY: CHRIS RUSSELL LJ Ll ILJI NICET CERTIFICATION NO.120520 SD I X LEV FIRE ALARM SYSTEMS- EL III SD SD CERTIFICATION EXPIRES:09.01.28 I I I I I I I I So F w Z u LA J L — J 1 r) Z N W rn Q F H Z cl� LU — — — — FU Ln III Ln I VERIFY LOCA�10 to Q O 0 OF EXTERIOR H RN o Z ZZ —VTR BE W H A J o E (0 (D w Q z p Z_ Z w G J G City of Arlington LL a Q Q Building Department SIZE:ARCH I—m APPROVED DRAWN BY:ANDREW OLIVER Kevin Olander- 02/18/2026 DATE DRAWT112/04/2025 REV DATE: No changes authorized unless approved by BUSINESS LICENSE# SITEPLAN the Building Official SECURSN790NE ELECTRICAL LICENSE# SECURSN954JC SCALE:NTS FA.2.01 CABLE LEGEND _ SOURCE CIRCUIT CIRCUIT TYPE CIRCUIT WIRING TAG STYLE SYMBOL TYPE DESCRIPTION AWG LENGTH FACU DAL DIGITAL AUDIO LOOP L CLASS B FIRE ALARM 1612 FPLR WEST PENN D980 RED #16 120-O' FACU RDPBUS POWER/SERIAL P CLASSB FIRE ALARM 16/4 SOL JKT FPLR I M RL RED #16 120'-0' NAC SIG NOTIFICATION V CLASSB FIRE ALARM 14/2 SOL JKT FPLP I M RL RED #14 150-O' NAC AUX AUXILIARY POWER A CLASSB FIRE ALARM 1412 SOL JKT FPLP I M RL RED #14 150'-0' AMP SPK AUDIO S CLASSB FIREALARM 1612 SOL JKT FPLP I M RL RED,SHIELDED #16 100'-0' NAC SIG NOTIFICATION T CLASSB FIRE ALARM 10 SOL JKT FPLR I M RL RED #14 2200'-0' AMP SPK AUDIO 16I250L JKTFPLR IM RL RED,SHIELDED #16 FACU KC SIGNALING LINE U CLASSB FIRE ALARM 1612 SOL JKT FPLR I M RL RED #16 1250'-0" FACU !,DC INDICATING Z CLASSB FIRE ALARM 161250L JKT FPLR IM RL RED #16 50'-0' FACU JIDC ITEST SWITCH I B I CLASSB FIREALARM 11616 SOL JKT FPLR I M RL RED #16 50'-0" FLAG NOTES: o FIELD VERIFY LOCATION AND INSTALLATION REQUIREMENTS OF REMOTE TEST SWITCHES AND SAMPLING TUBES FOR z DUCTDETECTORS. >a AHJ TO VERIFY LOCATION OF EXTERIOR WATERFLOW DEVICE.EXTERIOR BELL TO BE ACTIVATED BY WATER FLOW ONLY AND PROGRAMMED TO BE NON-RESETTABLE. PULL STATION SIGN: "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE DM L1 MAR M:003 PRIMARY ALARM SYSTEM INTO TESTTO INFORM THE MONITORING Y POWER FAILURE,SECONDARY POWER FAILURE STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. L1 M:004 AC POWER LOSS, LO V THIS POINT MUST STAY ACTIVE.' SS,BATTERY CHARGER FAILURE o L1 M:006-M:007 DM DM DONOR ANTENNA MALFUNCTION,RF-EMITTING DEVICE FAILURE o L1 M:008-M:009 PRIMARY RECALL 1 DM LOW BATTERY,ACTIVE COMPONENT FAILURE RM li_,� L1M:028-M:029 L1M:018 DM L1 M:010-M:011 DRY CTRL,FLOW(PSI O) RM ERRC SYSTEM TROUBLE,ACS PANEL L1M:030-M:031 ALTERNATE RECALL RM L1 M:012 DRY LOW AIR(PS40),PIV `} RM ACS TRIGGER L1M:032-M:033 FLASH HAT(FLASHING) L1M:013 WET CTRL,FLOW UM:020-M:021 J GM NAC TRIGGER z 1 DM T M034-M:035 SHUNT TRIP AC LOSS,HEAT L1 M014-M:015 _ DM L1 M:034-M:035-Z02-1 EOLTAM PER,LOW TEMP LE FOR HEAT DETC-R Ai Sorrom NAC AC LOSS,TRBL RT O OF SHAFT FOR S—NDAa L aacau Arvo /ER. aIrvRLEa Is Pa CM AUX-01 T — HHArIFLaSHIrvclAcrly l L1M:016 1 I FROM L1M:013 ■ilrr ^I WAATERFLOW BELL Eor rcssz3 Fl.aa)oErecioawmz<• T w O1 v'T / snorrvir relan�cTrvnnoeL�Aroa / I F AUX-01-11141 EOL D Q Q rn LEV. LEV.EO 1D:02 EMERGENCY L1 D:001 AMP2-S2-01 _ U Z Q 1°3 UPPLIES AMP1S2-01 0.25w UP iSTAIR3 J 2 I-0 D AMPI-S1-0� S N2-01 D I® u m m �I N1-02 COOP) MDF ME [OM AMP2 P TO A - - 1 Z 03 H II s N1-01 ELy-3..15cd s D O I JJJLLL 15cd 0- s L1 006 III 1 I s w Y L1M:020-M:021-Z02-1 EOL 025w la'-0" _ 15cA 0.25 _ AMPI 2-OB RM RM L1 D:005 tn m AMP2 13 t3 N2-OB Ip. li MECH:WATER O-0' L1D:004 M:37 AMP1S2 L1 :036 KITCHENETTE AMP AMP1 15cd SOURCE dS F 1M:027 S NAC AMP FACU ';° F 0.25w HVAC SHUTDOWN SP N2-09 HVAC SHUTDOWN SYSTEM '002 .01 HRSL-Q1 30cd HRU-02 0 AMPI-S' -13 13'-0^ AMP1-S1-02 w AMP1S2-02 0.25w �,,:HVAC z1,-B. N2-13 13•-0" N2-02 75cd N1-03 15� 13-0 "O 1w 150d 0.25w P 0.25w AMPI-2-1 P - N2-10 AMPI-SI-06 CUSTODIAL 15cd N1-07 FII sP T AID 30cd �1N.121w MOTH s'S RM. 133 S 0.25w MEWS MP1-31-05 P1S2-03 13d AMPI-S2-07 sP AMPI-S3-05 EOL 20k MI 025w N-O6 +s N2-03 N2-07AMPI-S2-12 N5-05 EOL 5.1k '5dt0'-0"C ILI t0'-O'CEILING S O S 15cd 15Cd 10'-0'C ILING N2.12 110cd 0.25w 0.25w j1MP1-S1-04 MP1-S1-03 2 w sP AMP1-S2-11 30W P WP BOTTLE STORA� G 0.25w L1M:0 F Y11-05 1-04 13-0• N2-11 U,,N��IQQN C,WP [S.�_AMPl-S1-07 �15cd �5cd D C C � G Scd u OM AMP1-S3-04 t3 ' 0.25w s>-0.25w s .25W CORRIDOR 1a'-o^cIN1-OS l� 15c0 Q C A P�-S2-0411 DRAWING REVIEWED BY: 0.25w N2-04 CHRIS RUSSELL D C 75cd NICET CERTIFICATION N0.120520 L1M:024 Mt,rc NING/PAVING I I i i I I I FRE/AV ERFACE 10'-O'CEILING ROLL CALL FIRE ALARM SYSTEMS-LEVEL III I IIIII � CERTIFICATION EXPIRES:09.01.28 I I I I I� D SP IN RM 0 F--- -- d AMP1S1-08 El Cl C] ffl El AMP1-S2-O6 _____ MP1-SI-ON-0'cE1N1-09 STORAGE C) C Cj N&O6 sP _ AMP1-S1-17 EOL20k -I 30cd 02w l� sP 15cd AMP1S2-14NOMEN'S N1.18 EOL 5.1k t3'-0" --- R CYCLE 2 w 30cd G AMP1 2-05 0.25w 2-14 ESTROOM -_ 13•-0• 0 0.25w 0 ClC 75cd5oL F 02=30w T-oNG - 0.25w C WP -s EILING MP1-S1-15 LOCKER ROOM WOR R MP1-S1-10 ENV.S 1-16 "03 MP1-S3-0J1-11 131 15cd FROM AMPI 5.01 PLOz 15cAp,25w LU 110cd W al .25w AMP1S2-19 L 0.25W WASH-OFF I— d WP N2-19 g AREA Z AMP1-S1-16 w m 15cd 0 W TO AMPIS3 S 15cd3-0 AMP1S2-22EOL20k S y `N2ANIP5S2-15 ^ AMP1S111 N1-17 3'-0' 0.25W .'-( 10'-0"cEIUN U N7-12 AMPI-S1-13 42-22 EOL 5.1k A P S2-17 75cd __ _ Ln 30cd 1.14 0.25w 1F� 2-17 0.25w w 025w 15od 0.25w 30cd CLOT ES OAMPIS3-05 AMP1-S3-04 N Z s .25 s 025 DRYI G/ NSO4 N O S s WASH UP ICo UNG ES BUL AMP1 1-14 /AMP1-S2-21 AMsP1-S2-20 P 0.25 C w BRID E BRIDI W ESTIBUL WP G SUP SOR 1-15 2-21 2-20 S a �cSP_IUNc J F a WP W AM -51-12 SR.ENV. �F� W STA ON DR N OP-IN pq�1r� I 15cd i 0 � Z N7-13 COORD. +s S AMP1S2-16 — WORKSOTATI 0.25w UNI L1M:026 FRO AMPI-33.03 Q W 3 + 0.25 1zt 0.25w �MP1-S2-18 1,1 d 15cd p 13'-0" 13'-0' 13'-0' '0'CEILIN 13-0 N2-16 •.. 0.25W t25 - 10'"CEILING 10'-0"CEILIN 0'-0"CEILING F 15cd > L1M:2 1M:025 Scd .25w FR MAMP1-3-01 9 TOAMPIS3-03 FROM AMPI-S3-027= J.zb C = Z Z AMP1-S3-02 AMP1S3-03 p O p O NS-02 NS03 Q 0 25.00d 0.25. w Q o Q Z Z 0.25w 0.25w WP . WP . . " r W G � _j ° J t o Q o Q W a City of Arlington SIZE:ARCH I 2 m Building Department DRAWN BY:ANDREW OLIVER APPROVED DATE DRAWW 12/04/2025 DAM Kevin Olander-02/18/2026 BUSIREVNESS LICENSE LOWER FLOOR PLAN ELECT ICALLICENS No changes authorized unless approved by SECURSN790NE the Building Official ELECTRICAL LICENSE# SECURSN954JG e z a' FA.2.02 CABLE LEGEND _ SOURCE CIRCUIT CIRCUIT TYPE CIRCUIT WIRING TAG STYLE SYMBOL TYPE DESCRIPTION AWG LENGTH FACU DAL DIGITAL AUDIO LOOP L CLASS B FIRE ALARM 1612 FPLR WEST PENN D980 RED #16 120-O' FACU RDPBUS POWERISERIAL P CLASSB FIRE ALARM 16/4 SOL JKT FPLR I M RL RED #16 120'-0' NAC SIG NOTIFICATION V CLASSB FIRE ALARM 14/2 SOL JKT FPLP I M RL RED #14 150-O' NAC AUX AUXILIARY POWER A CLASSB FIRE ALARM 1412 SOL JKT FPLP I M RL RED #14 150'-0' AMP SPK AUDIO S CLASSB FIREALARM 1612 SOL JKT FPLP I M RL RED,SHIELDED #16 100'-0' NAC SIG NOTIFICATION T CLASSB FIRE ALARM 10 SOL JKT FPLR I M RL RED #14 2200'-0' AMP SPK AUDIO 16I250L JKTFPLR IM RL RED,SHIELDED #16 FACU KC SIGNALING LINE U CLASSB FIRE ALARM 1612 SOL JKT FPLR I M RL RED #16 1250'-0" FACU 'DC INDICATING Z CLASSB FIRE ALARM i61250L JKT FPLR IM RL RED #16 50'-0' FACU JIDC ITEST SWITCH I B I CLASSB FIREALARM 11616 SOL JKT FPLR I M RL RED #16 50'-0" FLAG NOTES: o FIELD VERIFY LOCATION AND INSTALLATION REQUIREMENTS OF REMOTE TEST SWITCHES AND SAMPLING TUBES FOR z DUCTDETECTORS. >a AHJ TO VERIFY LOCATION OF EXTERIOR WATERFLOW DEVICE.EXTERIOR BELL TO BE ACTIVATED BY WATER FLOW ONLY AND PROGRAMMED TO BE NON-RESETTABLE. t PULL STATHE ION RESPONSIBILITY "IT IS THE RESPONSIBILITY OF ANYONE PLACING THIS FIRE ALARM SYSTEM INTO TEST TO INFORM THE MONITORING STATION TO NOT PLACE THE FACP PULL STATION INTO TEST. THIS POINT MUST STAY ACTNE.- EAT(ssza Flxea)oereCTOR ATSHUNTTRIP T OF SHAFT CTVATI FOR ELEVATOR 9PRINKLERLIS vsesENT.PRovIOE sm—FOR E—ATOR RECALL IF SMOKE RELIEF EDUIP.—IS PRESENT. HI— OF SPRI_ER IF PRESENT 1M:039-Z01-1 EOL/7k TV-9-BEAMS DOWN T DBEA L1 : L1M:043 H z OM FACP F F LIM.040 F F O VESTIBUL LE 1- �1M:Q42 / - \ / — o 'FROM AMP2 In 10w•cEIUN�I D. z-s MP2-�1-18 MM AMP2-S1-01 s AMP2S2-02 EOL 20 ry N3-01 75cd LOC Li M:039 75cd 0.25w FAT75cdw rn N 0 FROM FACP S 1 1= N g m 7 LOBBY/ LID: J Z=0 0 PUBLIC ROLL ALLB rn m U COUNTFROM AMP2 s 1s' MEWS AM � 0 L)L) L)ED CD1a'-10• T LJ LJ U g O 0 RESTROOM O w P2S3-01 EOL 20 N401 EOL 5.1 P2-Si-16 AMP251-15,N Y' m 15 N3-16 NS-15 0.25w LZ A 251-17 15cd iF qOR USTODIRN3-17 25. Sw 15cd Ll L)L) 00CC) ULD 00 LJL) o CDCD VqD w 6 AMP2-S1-19 N3.19 MP2-Si- 75cd FT WOR NAM1P2-S1-03 d P AMP2-31-02 43-22 1z'-s' Li M:041 g 0.25w N3-03 N3-02 75� FIREIAV INTERFACE RM 30cd 75cd 25 _ 0.25w25wI I — F � L -- -- P AMP2-S1-20 s WOM ' 1 III ❑ ❑ 151,d A��3ST1�4OM cd 0.25w 3-14 . 1s' Sod 1s' AMP2S1-23EOL20k 1s ❑Q❑ N3-23 EOL 1,11 w PERATIONS 15 AMPT-S1-21 1 AMP2S1-13 MANAGER DRAWING REVIEWED BY: MALL CONE. DRANA PA MENT/ LEAD CHRIS RUSSELL u/ 0.25w MALL 4J3-21 N3-13 h EEPIN AD WO R L WOR V ETATIO UPERVIS R 15cd 15c NICET CERTIFICATION N0.120520 ERVISOR .25w O.j5W0 WORKER ITCHE II / FIRE AIARM SYSTEMS-LEVEL III 5 P2 1 AMP2Si 12 CERTIFICATION EXPIRES:09.01.28 N3-D4 s s s s sP s s 1(T-0"CEILINN3.12 30cd AMP2-Si-0 AMP2-Si AMP2-S )7 AMP2S1-08 AMP2S1-09 AMP2-Si-10 MP2S1-1 15cd D2 W 10'-0'CEI IMl3-05 10'-0'CEIN�D6 10'-O'CEILINN3-67 10'-O'Cgf3..8 0'-0"CEILIN 10'-0'C 10'-O'CEILIN 9N3-09 N3-10 N3-11 0.25w 15cd 15cd 15cd i5cd 15cd 15W 15od OM AMP 5 .25w i 5 I .25w .2 w .25w I .2,5w AMP2S4-01 EOL20k I 6-01 EOL 5.1k 110cd 0.25w ES O CK P LiJ Z L1J U Ln M Z N O N W rn Q LU Z Ln W Q w N Q O Z Z Q o � 0� o � E co (� w Q z p Z_ z w G � J G L.L. o Q Q City of Arlington SIZE:ARCH D 24x36 Building Department DRAWN BY:ANDREW OLIVER APPROVED DATE DRAwH:1 2/04/2025 Kevin Olander- 02/18/2026 REVDATE: BUSINESS LICENSE UPPER FLOOR PLAN # No changes authorized unless approved by SECUR5N790NE the Building Official ELECTRIC ALUCENSE# SECURSN954JG SCALE:1/8"=1'-0") o z a' FA.2.03 1— —POR PR aRT.,-P—T. ­­-ER E_ WPP M 0 Mi=.M H­ (D E 11E I .—E ­E �RTSQ1 CON—LED' AII.AN- ( ­"T -REMOTE TEST SWITCH '80- SO ( )FR -I RELAY -I CONTROL MODULE SMOKE DETECTOR 4T . E .iessBwlglNssNow . c scow ; ss B ,­VAT11REM NO"E-1u1111�IUIEICAIIEUIEIIE�Ill�RI —M-1,P_.. D— L FIRE ALARM MATRIX OF OPERATIONS -DR.-LE NOTE:PHONE LINE TROUBLE SYSTEM WILL ATTEMPT TO CALL CENTRAL STATIO IFAILE ZO �cn°srE.PE—Vir N—P. VOICE EVACUATION MESSAGES NOTE:AC LOSS DELAY OFF HOURS. T '"T _.D.-B .D.- again­R 1-� Ng- L VOICE MESSAGE PRECEDEDAND FOLLOWED BYAMINIMUM OFTWOSETS OFTONES PER 18.4.2. -5 TIMES. § Z- mo REPEAT THIS CYCLE 3 �&0 , -0. ­61 IMP HAND BOOK-IF VOICE ANNOUNCEMENT IS MADE AND IS NOT FOR EVACUATION,TONES DO NOT 0 z. sic LcaP P I 8-E &� NEED TO PRECEDE THE MESSAGE.THE STANDARD"MAY I HAVE YOURATTENTION PLEASE(x3)..." 1UID1 13 z. w t-� FIRE ALARM AND EMERGENCY COMMUNICATIONS SYSTEMS PRE-RECORDED AUDIO MESSAGES g 'Z- ".11ER To USE OF TEMPORAL CODE 3 SIGNAL IS RESTRICTED TO EVACUATION ONLY AND IS NOT E.—D.. P. N CE ��c RESTRICTED TO FIRES.THESE EXAMPLE MESSAGES ARE TO BE REVIEWED AND APPROVED BY C, C, 0 =�F=)H.A.M-E THEO NERANDADJU TED AS NEEDED.NO RISK ANALYSIS HAS BEEN PERFORMED BY SSNW OR W S s Mwc. DB­ 15 THE OWNER OWNER TO PROVIDE SSNW&AHJ WITH A COPY OF THE BUILDING FIRE SAFETY AND C, EVACUATION PLAN AS REQUIRED BY THE IFC 404.2.1&404.2.2. ­AT1­.TH­TECT- -- 1 0�j�)�/?I SERIES SPEAKER/STROBE GENERAL FIRE ALARM QD�1DUAL MONITOR MODULE (��LM�1MON MONITOR B�'­.12L.XwMANUAL PULL STATION �3%�D.E.TECTOR BA,S E CE.... —N_-­=. VOICE MESSAGES TO BE PLAYED AT 520HZ FOR INCREASED INTELLIGIBILITY. • Z 0 DBN_ 1. EVACUATION MESSAGE(FIRE ALARM):THREE TEMPORAL 3 SIGNALS MAY I HAVE YOUR DEVICE TROUBLE 0 T _TE.N__ FACU TROUBLE N-H (M. N�H ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION PLEASE. THERE IS A FIRE EMERGENCY CD H N REPORTED IN THE BUILDING. PLEASE EXIT THE BUILDING BY THE NEAREST EXIT OR FACU AC LOSS EXIT STAIR. DO NOT USE THE ELEVATORS. FACU SILENCE 2. FIRE ALARM PRE-TEST MESSAGE: THREE CHIMES - MAY I HAVE YOUR ATTENTION FACU RESET • EA MAY ST I ... PLEASE. HAVE YOUR ATTENTION PLEASE WE WILL BE CONDUCTING A TEST OF POWER SUPPLYTROUBLE 14 A THE FIRE ALARM SYSTEM. PLEASE I DISREGARD ALL ALARMS UNTIL FURTHER NOTICE. WE POWER SUPPLY AC LOSS L ON 0 F THE TEST. WE APOLOGIZE FOR ANY WIRELESS COMMUNICATION TRBI INCONVENIENCE. -17 WILL NOTIFY YOU UPON COMPLETION WIRELESS COMMUNICATION AC LOSS(l) 0 Z 3. FIRE ALARM POST-TEST MESSAGE: THREE CHIMES - MAY I HAVE YOUR N U 10 E:I ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION PLEASE. THE FIRE ALARM TESTING IS ERRCSYSTEM COMPLETE. PLEASE RESPOND COOPERATION. U) E] pnm 4vm POWER SUPPLY PRIMARY POWER FAILURE 0 • 4. EMERGENCY SITUATION ALL CLEAR MESSAGE: THREE CHIMES MAY I HAVE POWER SUPPLY SECONDARY POWER FAILURE 0 • CE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION PLEASE. THE EMERGENCY ACTIVE SYSTEM COMPONENT FAILURE 0 SITUATION HAS BEEN RESOLVED. YOU MAY RESUME YOUR NORMAL ACTIVITIES. ....0 DONOR ANTENNA MALFUNCTION 0 • FRI I • El CM 4 0 &*CE 5. [RESERVED] ACTIVE RF EMITTING DEVICE FAILURE 40 ET 6. RESERVED LOW-BATTERY(,70 PERCENT) LOSS OF PRIMARY POWER(AC LOSS) III -L-77 7. [RESERVED] BATTERY CHARGER FAILURE J U-1 ED 0 ED 0 0 E7J KI El M73 =0 OB03000000 a] 21 0 MO INTED BEHIND DAnz 8. [RESERVED] v­,E] 9. [RESERVED] FIRESPRINKLER 'THIS SPRINKLER TAMPERIPN` j 1 MUSIC FOR TESTING PURPOSES ONE CHIME IS A TEST OF THE LOW TEMP SENSCIR EMERGENCY AUDIO SYSTEM' (MUSIC FADES IN FLOW SWITCH 0 0 0 0 0 0 0 PRESSURE SWITCH 0 0 0 0 0 1019 LOWAIR VOICEJMNS FACUNOICE MICROPHONE DRAWING REVIEWED BY �DAA2 5025 POWER SUPPLY�F PRE-RECORDED MESSAGE ACTIVATION CHRIS RUSSELL .=�2-303,'CONTROLPANEL =XITIET18­1 NICET CERTIFICATION NO.120520 4 1 ­ T. . __.. __ TAL A=­AMeAiTPnvuLcuuTioxsFoqEAnEgv FIRE ALARM SYSTEMS-LEVEL III 8WSUPPOPUIIII'1'1=�LEWRIOIEIRPRRLWP PULEI CERTIFICATION EXPIRES 09.01.28 111 EPT RW Ell W LOWER FLOOR REIE.T.— 1--E.P. MANUAL PULL STATIONS 0 0- GENERAL AREA SMOKE 0 0 0 HRU-01 DETECTOR HRU-02 DETECTOR LEVEL I-ELEV.RECALL SMOKE 0 0 0 0 0 -EF­-7] ] UPPER FLOOR —T MANUAL PULL STATIONS 0 0 0 0 • 0 Mai M1» 0 GENERAL AREA SMOKE 0 0 0 0 • 0 LEVEL 2-ELEV RECALL SMOKE 0 0 0 0 0 • 0 LU ❑ GENERAL ELEVATOR esxex� AMR11BAILE ELEVATOR POWER LOSS.... PSN-106 Z + ELEVATOR NECK HEAT DETECTOR 0 0 0 0 0 0 we Uj ti I D 0o YYYYYYY s. ELEVATOR MECH.SMOKE DETECTOR 0 0 0 0 0 0 0 0 U L-1 ELEVATOR PIT HEAT DETECTOR 0.0 AFT SMOKE DETECTOR 0 L/) ELEVATOR SHAFT Z L ,T7� C) --r F] (1)WIRELESS COMMUNICATION DEVICE BE ELECTRONICALLY SUPERVISED.WITH MANUFACTURES INSTRUCTIONS C4 W..L. BI HONEYWELL WIRELESS COMMUNICATOR USES TELCO#2 TO TRANSMIT FAULTS TO THE FACP.TELCO#1 IS USED TO 11 2 Ljj 00 0 0 REPORT EVENTS TO CENTRAL STATION.IF TELCO#1 IS NOT OPERATIONAL TELCO#2 WILL BE USED TO REPORT. < Z LU FW L/) LLJ > mOo < I Do 0 _.P Ll �FDI MODULF O o 0 0 G T_ 0 0 10 F- 0 .001�.E OR —IT < CO (D 0 Z NAC CIRCUIT#4 - C) t2 Z LLJ C14 _j (j\�Vffi2FITRE COMMUNICATOR l..T. NAC CIRCUIT#3 (.0 V U 1E ­E­IR BATTERIES(2)24V _DETERMINE BE" A�N­OEMMUN CE TDR NAC CIRCUIT#2 5 FCM-1 CONTROL�MODULE < < INI W M "I rEREl M,M "ore _TO,INST�. NACCIRCUIT#1 ­CMI P., City of Arlington ITE111111NIT11 1XTNE`1T1o1­1­E1TETD%E ­.—T—IT....UNI—R-1—E-1 SEE DETAIL B Building Department DRAWN SY'ANDREW OLIVER FA-OE APPROVED DATE DRAWN:12/04/2025 REV DATE Kevin 01ander- 02/18/2026 BUSINESS LICENSE# SECURSN790NE No changes authorized unless approved by ELECTRICAL LICENI the Building Official SECURSN954JG DEVICE WIRING DETAILS FA.3.01 PANEL (NFS2.3030D(FACU))BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) STANDBY CURRENT SECONDARY ALARM CURRENT QTY PART NO. DESCRIPTION CURRENT DRAW(A) TOTAL(A) CURRENT DRAW(A) TOTAL(A) 1 NFS2-3030D(FACU) FACU,ADDRESSABLE ASSEMBLY 0.000 0.000 0.000 0.000 1 AMPS-24 ADDRESSABLE POWER 0.130 0.130 0.130 0.130 SUPPLY/BATTERY CHARGER 1 CMIC-1 CHASSIS WELL AND MICROPHONE 0.075 0.075 0.075 0.075 NFS2-3030 FIRE ALARM CONTROL 0 UNIT MAIN BOARD(CENTRAL - 1 CPU2-3030D PROCESSING UNIT),120V POWER, 0.340 0.340 0.340 0.340 0 INCLUDES CHASSIS,DISPLAY OPTION PANEL COMPONENTS 1 DVC-EM DIGITAL VOICE COMMAND, 0.300 0.300 0.300 0.300 EXTENDED MEMORY 1 DVC-KD DIGITAL VOICE COMMAND, 0.060 0.060 0.060 0.060 KEYPAD 1 LCM-320 LOOP CONTROL MODULE 0.13 0.13 0.13 0.13 LOOP EXPANDER MODULE, 1 LEM-320 PROVIDES EVEN NUMBERED SLC 0.1 0.1 0.1 0.1 N LOOPS z 1 RM-1 REMOTE MICROPHONE 0.020 0.020 0.060 0.060 O 1 UDACT-2 UNIVERSAL DIGITAL ALARM 0.052 0.052 0.087 0.087 - COMMUNICATOR TRANSMITTER-2 N 1 SAL SLC ALARM LOOP 0.000 0.000 0.200 0.200 D a CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW(A) TOTAL(A) CURRENT DRAW(A) TOTAL(A) 3 m REMOTE LOCAL OPERATOR z=U RDP LOC 1 LCD-160 W/RM-1 CONSOLE ASSEMBLY- 0.300 0.300 0.325 0.325 W z U. " O CONFIGURATION 2204154 ^W INTELLIGENT NON-RELAY Linto m 2 DNR W/FSP-951R PHOTOELECTRIC DUCT 0.0002 0.0004 DETECTOR/FSP-951 R. FLASHSCAN AND CLIP MODE. ADDRESSABLE CONTROL MODULE CM 2 FCM-1 W/FLASHSCAN,1 CLASS A OR 1 0.000485 0.00097 CLASS B ADDRESSABLE DUAL MONITOR DM 11 FDM-1 MODULE W/FLASHSCAN,2 CLASS 0.00075 0.0083 B ADDRESSABLE MONITOR MODULE MM 1 FMM-1 W/FLASHSCAN,SUPERVISES 0.00035 0.00035 DRAWING REVIEWED BY: CLASS A OR CLASS B OF DRY CHRIS RUSSELL CONTACT INPUT NICET CERTIFICATION NO.12052D FIRE ALARM SYSTEMS-LEVEL III CERTIFICATION EXPIRES:09.01.28 AIM 1 FMM-101 ADDRESSABLE MINI MONITOR 0.00035 0.00035 L1 MODULE ADDRESSABLE RELAY MODULE W/ RM 8 FRM-1 FLASHSCAN,2 FORM-C DRY 0.000255 0.002040 CONTACTS ADDRESSABLE LOW-PROFILE OS 5 FSP-951 W/13300-6 PHOTOELECTRIC SMOKE 0.0002 0.001 LIJ DETECTOR.FLASHSCAN ONLY. z LOW-PROFILE,INTELLIGENT, U HO 1 FST-951 R W/6300-6 RATE-OF-RISE THERMAL SENSOR. 0.0002 0.0002 to FLASHSCAN ONLY. N00 O ° 2 ISO-X SLC LOOP ISOLATOR MODULE 0.0004 0.0008 w LLJ Z M < t//) LLJ Q w DUAL-ACTION ADDRESSABLE } > ❑F 9 NBG-12LX PULL STATION.INCLUDES KEY 0.000375 0.00338 Q O LOCKING FEATURE. = 0 Z TOTAL STANDBY(A) 1.525 TOTAL ALARM(A) 1.80700 Q ° ti I- s REQUIRED STANDBY TIME(HOURS) 24 J REQUIRED ALARM TIME(MINUTES) 15 r w G � J C, J AIL dM < Q SECONDARY STANDBY LOAD(A) 1.525 24 36.59 SECONDARY ALARM LOAD(A) 1.80700 0.25 0.451750 SIZE:ARCH D 24x36 STANDBY AND ALARM SUBTOTAL(AMP HOURS) 37.05 City of Arlington DRAWN BY:ANDREW OUVER DERATING FACTOR 1.25 Building Department APPROVED DATE DRAWN:12/04/2025 SECONDARY LOAD REQUIREMENTS(AMP HOURS) 46.31 Kevin Olander-02/18/2026 REV DATE: PROVIDE(2)12V 40AH BATTERIES BUSINESS LICENSE# No changes authorized unless approved by SECURSN790NE *BATTERY BOX SIZE CAPACITY NOT SPECIFIED.REFER TO MANUFACTURER DOCUMENTATION. the Building Official ELECTRICAL LICENSE# SECURSN954JG BATTERY CALCULATIONS FA.4.01 PME L r0 CIR M 1iAL-W rtCURS EM (SECONONBY POSER SCUR NISI IN' OBA PIING CAL MA%RV WSH US BATTERY '. 90 ORANNU Y` OTALIAU RANOU UNREHT SECONDARY ALA TOTAL PU IN PgM�T6P01Ni REPORT ENT .cIN`IA) 3 SCURRNIT LA'T STVOLTAGE: 'S.` C9ItOP%.I-,DROP CLINEST PANELCONPONENTS PS-S EXO N0 OTY Nuw1A1 mU51A1 RAW IN Tu51A1 TU CA1N,cRRE WIRERNISTN9CE 307 RE I TCTIN ucl'rcrouIT LENEST ADx DINGST N.CARD AMP. AMPS S-E CARD MRS S©L t cIRCUrt WNNG PROPERTIES V14n iFRmINAC114AWG,2CONG.SOUG COPPER FPLPMANALDG UNSxELDED .CIAO WRRNiIA,: nle SPARE (D ' PFCM�10 AWIFIASxSCANONTLASSAOR� COOn 0001T COOT O.pOT E oCURRE ALIVE IDI; ISSOANCE MEASURED USING DRAWN SEGMENT LENGTHE WITH 10 W G,ADISTIONN.LENGTH CN-CULATED t CUPPENT SCWLED STROBE,CEILING,WHITE III 0 0 O.p18 0.015 NEAT(AI ALAR INSIDEFROM FROM VOLTAGE DROP FRON VOLTAGE DROP Exr1A1 M MP_oMS -ATS.CE VOLTAGE DROP PERCENT 10 sPSCWLED EANE R-OBE 0 0 PUNS BIB SPSCWLNTE CEILING WS IOI 16CD -H LIT CDC I I ECEIONG ISW D➢ 1111E LED Nt 1 sPSCWLED -RESECEIUNG 30WIDUCEIR 0 0 O.W2 OAIINO. SPSOWLED t'I% SPSOWLED IiECEIUN OBE LED ISO 3 sP3MFO VARE. SPEAKER STROBE WNSTE All STROBE LOU0 0 LRN S_ N- SPSCWLEDVARE TTECEINSW COT LHNC C.I. S. - E. 16S% RE,SPIEN(WNTEER STRWALLOBE LN �} 3 GROWLED REWH ��ER oEL N 0 0 0.G22 O.OB6 _O CWR , SPSLMGN A.ADC DPEAxERCEILINGSiTRROOB1.DISCO0 0 O.p10 O.IB L S. 2]4X _ N2r18 -LED -RE35W CO22 p424 23 S.td2mT 006 1B.TS 6625 CqX CwR 2 SPSLWIGEO OMGOOP SPENKERSTROSE, 0 0 0.p22 O.ON RE,SPEAKER STROBE LT15 ] 9F9CWlED RI OI EDNCERTILINSGEISW 0 0 0.GI0 0.126 LEo UNOW ECEIURI EW .7 S. SE STIM&J OOM 9m p]d0 9.45X ➢ ➢ STANDOAOW,CEILINGL1E SOC➢ CO22 0314 2B BIR04B PAS 19M CTI SIS% 1 9F9CWlED CLININEHI ECEI NG 30C`CDD� 0 0 0.G22 G.OII M ➢ STAND�W.CEIN113 -LED ELLIST. ➢ SSG➢ CO22 B. W SANG" PAS 18S1 C9I IS,% WA 111- 4 sF9LWlED CLININEHI FARMLINER -ORE LED 0 0 SIR PIGS RE,SPEAKER$1RGBELN HAS ED rTA 5 SLIMED VRRE,SPEANEER STROBE LEG 0 0 0.010 04B NIOLEFDD FF EtEERRIUS LOBE V CO22 0112 13 SWISS] P. 1BM C960 1.T0% O 1 sPSMFD STROBE 0 0 O.W2 OAII SPSGWLED -CWRE=E.RlU COBEIFD 15CD C01B 009 OIM12t OI 1R49 C9T0 4.T5% ALLSOW DD RE,SPEAKER STROBEIF➢ ED 1 SNMA➢ REWH­CBEIF➢ 0 0 0.G] G.0] .7R% CLNIREHI FARM GE1 R� SPSCWLED EE aISUINER`OOPBE - PAU 0.0]382 941 0990 4.8D% s[ 10 9F9CWlEO P O.IB B" $PSWLN C01B OIB Si- C 1841 CBI 4N% M �} a sNMAnVRRE 0 a 0.01e 0.1m vo575nGE`CROP FFRNM cP lone=RENGT�FROM v�vlouH U)z RFaEMANIuc CURRENT(A) Z ®} z sPSMEn E^ Rruaoco un 0 0 0.m2 0.M4 M TOTALCIRCUNCONSEM POSSERSUIRaIm MAxRVWTACE DaoP: 1I O RPGPEANERR-GE LT EC RATING O4L ®} s sNwTAn 0 0 0.m B. uIT 3 SPAN IRcuT RTvoLTAGE:` zp.4G N N1 PgM�TDP01Ni REPORT cINCIN'`GN CURRENi(uj ItOP%'. 9.M% N E VOLTAGE ism So Nd ED , sPBWIFD SPEANEER STROBE LED 0 0 pqe 0➢15 T ROM RE oPERATEDrvU 18 i D OFOcul N E,fT 7 AL CURRENT WIRE RESISTPfICE SN ALLI2. (rniLEGGT3 ID Q M 5 sNW3am sµwNORCD ME sr ME 0 a 0.ces a4zs CIRCUIT PaoPErsTNVHn FHPm INACl14 AwG,zCONG.sOUGCOPPR RLPm ANALOG UNSMDOED .CIAO CURRENT G. SPARE ( IALAL3cE101: s.ss F 3 V [fit WP E CURRENT M EI'/VIP t �M➢E➢ OSTn'..SC0.LEDt1oC0E 0 0 O.aeS 0.095 NI EXi IAI P019iANCE FRN NT WSIBIM NENOUS PERCENT VpLTAGEDPOP FRW VOLTAGE OxOR Na DISOANCE MEASURED USING DRAWN SEGMENT UENGTHIS WITH 10 a0xno0lTarvAL(ENGTx J Z=o 0 RSEM roTU_G.(AI O.wI roTALAuaM IN RE,9PEANEN STRHWELN Z m m REUSIRN STANGBVTIME(xGUu1 LO w REDUIaEn HARM THE XI INUES) I MGM -LED SECONCRIA STANDBY LOAD(A) 0 ^W ar 9ECONGAMAARM LOAD(A) GO 0,1IQ -LED STANDBY A98D AURM SUBTOTAL TAMP HILL RR) m SECONGARY LOAG RECUIREMENTS(AMP HOURS) H3-0S SPSCWLEN IER R INCIDEN OBE 15CG p.010 CWe 6 0 -E1Y EGA RUDE-1 GOT CHED UM N4 SPSCNLN -REW CR R UNGBE(FD 1BA5 % 663% IMCG ECS I IS P-1 OM 19'I ER2% RE SISOWLED ,WfHIEAKECEE LSTROBE LEN 6.BBX ALCIRRIENTSOM�cIRIN.TCU 0.34 pATING O4L 2040 KM%RVOLTAGE gLOP: 04 RE,SPEAUR SWHIT-ILIROBELN NI POINTiO-POINT REPORT -CIRC(UTA) RE 3 111R1E(AU'i RTVOLTAGE:`OR GG_GNGF% 1.95% SPARECIRCUIT MIx.OPEIuiIONAL 0X No'. NiAL CARDCURRENT NCI'LUITLENGT3 SA N311 -RE N FCEIO N .1S 16 00 0. d T.TM%2W MREREST FT CIRCUIT WIRING PR SVniFRA(NA)14AWG,2COSOUGCOPPERFPLPMANALDG UNSxELDED MCNNCURRNiA,: SPARE CURRENT U➢ILS 32 NI O C0B C3T2 03 a NCE DISTANCE MEASURED USING DRAWN SEGMENT UENSTINS WITH 10 W G,ADECTIONAL LIENGTH C-ULATED PONLED NT ND-13 S I.RGE SPARE % REXi1N ALA d3TANtE FROM FROM VWTAGEDROP F0.0Y VOLTAGE D0.0P ENTwM PRENROUS as(D)M EI L % S 8.3S% R. SPSCNEN -RE 1NA CIS S., S.13ASS COd ?D.32 C08 CST% N3 -LED ISCG ECIS pa 10 OASm S.I B.1% .1. SPEWLED RE,S1ETANGREI -CRE LN RPSPEANNER sC RGNELLET p.]3 z RN% rticilu" p.e3z aE.sNPEA�KEasmoBEle➢ .0n SPSCGLED ITECEIU G CIB Ot4ST3d 0.03 20.20 62 C9B% SI 0.92X DRAWING REVIEWED BY: I.A. EBSX CHRIS RUSSELL 9.0e X NICET CERTIFICATION NO.12052D 1.50% N323EOL5.1K -LED 15CG EIII H RE ALARM SYSTEMS-LEVEL III RAS SPIGNED NDEW�OBE LFD 3pCV 0022 OI9I C0491M 001 20.SB C31 lad% CKWLAiN]H METN]O8: RE,SPE,ER TEE LN RESISTANCE FROM PREVIOUS 1.INRE RENT-CE1gTI)x 2 x GIST.FROM PREVIOUS IFII CERTIFICATION F%PIRES:09.01.28 1.I% VOLTAGE DROPFROM PREVIOUS=aEgSTANCE FROM PREVIOUS(GI x REMAINING CURRENT(A) WHITECEILINGSPEOWLED L 1.SN TOTAL CIRC(UNT CURRENT0015 MA%RVWTAGE DROP: E.SPSCNLN N. L 1- GRIN ING SLI43I2 2002 C38 1- MPx.CIRCUITWRRENT SPARECIRCU S VOLTAGE:` M'LI NA PpM�TDP0I TREPORT (A)'. 3 CRRENi(uj: ItOP%'. p.teX NIAS SPSCNLN CE,NOL 1- GRIN CA I I S_ .,SI C3S 190% L IT NE.% 1. END OF LINE VOLIAGE ED _ER i PREM PRE i N S. 1] SPS_MED TWURSPEAKEWN R STROBE IFD iNA CIB OM B COSO4R If p0 2m pA 1.&% U NDI` VAREI�INTAN 307 ALLI RE IL6LUNIRigLEGGTN YRRE,SPEN(ERSTROBELN CIRCUIT WIRING PROPERTIES V 14n FPLARP C)14 AWG,2 CONI SOLID COPPER FPIRG ANALDG UNSHIELDED .CIAO CURRNT(A,: nre SPARE o,CUR ANLE IOU 1. tS ESL 5.1K SPSCWLED 35W 1.9s% SPARE CALCEI3ESS CURRENT ANIFROM PR ISSOANCE MEASGRED USING DRAWN SEGMENT LENGTHE WITH 10 W G,ADDITIONAL USINGTH CALCULATED % I L OEV�i0G5 I➢)=YnRE RESISTAHCEINFT1 x 2x DIST.FROM PR-GN IFII ALARM 019TANtE FRN FRO VOLTAGE DROP RUNS ACENROR LTAGE DROP FROM PREVIOUS=RNISTANCE FROM PI3EVIOUS(G)x REMAINING CURRENT(A) DESNELABEL _NI EXi1M WS(01 M I-E- RE,SPEAKERSTROBELN p.113XT W CALOU ON ME­ RES-CE FROM i- OUSBO WIRE RESISTANCE(M x 2 x GIST.FROM PREVIOUS IF) GO-DROP FROM PREVIDES-RESSTANCE FROM PIEVIODS(C)x RNNNING CURRENT(A) W ICTA Wrrcu 20.40 qtR HIS PaMTga➢IXT REPORT aR`(G) 3 SCRNNr(AIT vaTAGE. RDP%. nx sPARREECROUlT NESS US ENDOFA LINE vOLTAGE: I M Z i.CARLCRRENr ` routcwcUNLNCTx N C) RNIBT 2. I N v 1M2 HPLI(NAC)14AND,2COND.SOLID COPPER 6PLPm ANUDG UNSHELDED .cA30 WNRRT(AI: 'G E NwRIErvT WINE Axc MCE(MI' Q INWGMDISTANCEMEASURED USING 0.W%ADIlTaNALLNGTHcuc D ARE CARD CURRENi nEssr z00 w 11J DEVEELABE. WGART NO SEGMENT LENGTHS , DESCRIPTION DANDELA$ W_(A, xxeXT1A1 M PRµ�V`E11OLN, RES-111EIR NO S VOLTAGEAIOENCE TOTAL VOLTAGE DROP �E SN" � � � ce W -1 SNMGF➢ O S','.CW,VEMOBE 11acD ALIAMCOBS LUp423 T 1. C6232m 2il.14 LIE 1- W 0- saz A-..sPEA1a=RSEOBE, pees pia I 0311se zpI p3] x /\ NSOS GUT OµsFeWu`a:DRLED E EE GRIM BASS w SGUNMs 19. a4s zz�M% < O oumOoasPEAla=asraoBE, X Z Z ,]X a' off oL0r GUS IQ)WINE RESISTANCE SM x 2 x DIST.FROM PREVIOUSRTIEO < I, VOLTADE CROP FROM PPEVOUS=WERSTANCE FROM INEWOUS(mxRErnunINGWNRRr(A) V CG.EM9uM- PONE..... O O Z Z TOTAL DIRCLUT w rz ❑ M4x.CIRCUITWRRNT W,CUB VOTTAGE M'LI PROP d w � w ISRpNT.TD,GMTREPORT IN `N:(Arr rsOPx p.m% G _ o 0 Q d RRE`Ixrx. L.L d � d Q CURRENT ORC LEN 2. FPIPM(NAL)14 AWG,2DONG.SOLID COPPER FPURP ANG-OG UNSHIELDED .GIRD CURRENT(A: nre SPARELIAG CURRENT YRRE( nEANCE pN i0Ti0L LCILCUrtOTM ?✓2 SIZE:ARCHD 24x36 CIRCUIT WRING PPOPERTLES, U SR. 1I DRAWN SY:ANDRES1 OLIVER DISTANCE MEASURED USING DRAWN SEEMONT UJINGTHIS WITH ,pppxADDITGNAL(ENGTxDALW(AED E RE City of Arlington cW PARTNO CANDELAS RENTaI ERnuM agFMoM Building Department DATE DRAWN:12/04/2025 oomo�RPE C,�LETa00E, APPROVED REV DATE: D S(D,- RERNISTANCEHq X2XDIST.FROM PRENOLS D Kevin Olander-02/18/2026 BUSINESS LICENSE# - ous(n,x RPMAxING WRRErvT(A, SECURSN790NE No changes authorized unless approved by ELECTRICAL LICENSE# the Building Official SECURSN954JG BATTERY CALCULATIONS CONT. FA.4.01 RAIR,...NEI. I A RRRAUER -RE—R1,111111 A B A. $-ER iM GIE A BA 11 E­­ ARII.Ea A A B A- Mlnsl 11 1— A B A. Mtn Ex ­E, _RE A B A xwa - OnW aRSI WRN - �E Z FR A.-...R—RIALE .CRmR n V., ­.—BRIEREERIE B_ 2, A, CD M.RE 1.E M. E1ARE__ .1E -ILPm E1ARE__ .1E ZT= R,= RER 1 REARREULEERL NA- RRA­ RAF.1�1 .R REA_ A '=RR 1 .1. RE, . LL—Em oR 2WRE.E.-RET—RUI RE, mm"LL E. I R11— .1 2W8E,.E.­""EEm .PI 11 RA AEBR_NE­,,mR 2-W RREE,.=8_­RE'ERRE­EE_T—LLR O EEER ULEERR RoEZ, Ao)IAARII I1I.R IRA—.I'—RAE All R o. -W-RR'E=='.ERR'E"­ AN',R. E"E_LEAR Ln U O 7 wRE PE.wEPn oREUn E.sv.ER_.EEUER MR,��'E' '' 'E WR1=ZEE E70..EE- WIRE,SP R z oH 11 R­ All ­1 2­8*­'MEEUER =ZE'E RE n LL .I 2-WRI=�IE7'R oz AIR 1� RNARE All ­1 o. ­­ E­ ,0.RRIoEE- —R1WRE.=ERE7R0EE­ IWRE,E.A�RE7ROIRLER'Ej_ E­ l=�ETRI�E­ 1WRE,='R'R oz AIR 1 11 R1121. .11 A. .1. ­11 ERE- BETROER URR R ER ` RE .11 2WRE,='AT­Em m-11A $w__R ANII�R RE.. E­ —RE,='­EEm RNRAR I u —R-�.ELTRREE. RE I-RE WIRE,SP­E"­R0EE- BA-T.A.P­M_­­E­­E m-11A ......... m-11A R—LED -RE.S�A�KEE_­08E m I- AR—I. I LER OTLI EE­ . =R AIR A ARI.R,EA NE RREBEALE ­R­ ERARE.­ -A ­U­ sz DeL.E ­TI­1 1E­�11­1 ­11 IR11 IR11111 IR=11 REEI­E 1111­11(M ­­.NPEAAERR1MIEI­­.V)U— 11­=RE-IROM lR) RREN7 ——I— RE REE—E ­ I RE I A, DE­S 2G_AR­E I UU7­E I 111T 1­1) DRAWING REVIEWED BY 11".11 IIT=F— 11FRRA RAR _R_A NARE_ CHRIS RUSSELL 1WRE.=RET.EE­ ­—E E_ET— R.RRIALE A—EIERE ER NICIET CERTIFICATION NO.120520 AP.L. —RE,S�­' Em A. .­R­ 11 WARE R" Hzae RE LL EI 12P FIRE ALARM SYSTEMS-LEVEL III ­.(EP.-IRREIR 1A—I..­R P—1­ RP.- xB CERTIFICATION EXPIRES 09.01.28 —1— RE $_R ZZACZIR)REER—EF.. ­FRM RE E -RE,.�-E_TR0EEUER P_..RR RRERARAB NEI 2 1 IRE I�ME'IVE IMEA`."' A1 —1 T.­1.-1.­.E 11—E 2'R"PRE ..'RA`REE- AmPI-11 ­R 2WRE.=�­E­ A A AIR A A __ TR111UER A z E "I — I IRE I.A'KI'M M ­—RALE 11 L" I RE IM-5-Aq I EMMEER `..R`AW—ER'ZM - EE IIN 'E.T.1 E.�UNE A ­E N­ A z AIR 2 11 11-1 All ­1 �­­RR.PIOIERTEE­­(.PEAKE1ENNIEI­2..E.R— w—I— RE E 11 IN, LLJ a® "1T1C%`RI E_ ET—E M RE ­1A E­ -1R1=ERE7RREEM A RE_ R z oAI RRw All REO nE'" �_IIMM2.IK E­ R LU m'L ALL I A M ..A U Iff'.ZER ET.:;f ­R­1­E 11—E E VI�­IE X­ �IR . "" "=-� EE_( A z R­ RAR ARZME—RI M E, 1- I Z RA,T_ NAR_ (D L A 2 M ER PA E I— AA..AREANE­E­ MA- —RAR.. CID ..A".1 11 1— _T_ 21. M < L 11 Uj Z (SP.­IRREIR­I..E.R P—IP" RP.- w­R 11111IT— 11 ITAIIIIIALI 1�1 A.11.AREAREA..E.L. AR — _T_ A_LVR' ­E NE- REIAENT­R.1I RRI ARRR­UN— MRE MT.A—"(.) —ATREEREE NI' > ­11T RIN.P.I.Tl. 1.­R(EPE­IRAIR­2­A.-OPRER 1­—.P— RE 0 w—I— NRARE__ RE c' -E oz < UI —E ZT.A'."I I AIPI­=INIE�I I­E Z Z REEI­F­PRE-RR BIRRE REEI­E­I I I F11­11 IM T_ 0 0 --EL IART. REAAAA­ "M — "I --EAT.—E REI" A­­;�R ""G OR'R'�RE_, TRE F- 6 ­D'0T0R'SAP'­'RLS'T'­ < < (0 (D 0- C) Z Z C'4 —IIRII-IRI—E. T, LU _j T.'A'_UER o. ­.1 Q0 cc� REV.E—I M < 1, —11=1 2 LW IRA.R—I < PR- ­1R,A RE.I.R.AR-'I City of Arlington LL PRE-A —E AT PR­1­1E 1­1 AT :A Building Department DR SIZE­N ERCH D Y'AND-OLIVER APPROVED Kevin 01ander-02/18/2026 DATE DRAWN:12/04/2025REMDATE No changes authorized unless approved by BUSINESS UI SECURSN790NE the Building Official ELECTRICAL LRCENSE# SECURSN954JG BATTERY CALCULATIONS CONT. FA.4.0 3 SECURITY 1 L U T 1 1 Product City of Arlington Submittals Building De. . APPROVED Kevin 01ander - 1 1 • No changes authorized unless approved . the Building • Fire Alarm System Arlington Operations Center 19620 67t" Ave NE Arlington, Wa 98223 r 1619 N State St.Bellingham WA,98225 t 360.734.4940 f 360.647.9540 www.ssnw.co 19SECURITY S 0 L U T 1 0 N S Device LiR Manufacturer Part Number Description NOTIFIER NFS2-3030D FACU ASSEMBLY NOTIFIER CPU FOR NFS2-3030 CPU2-3030D NOTIFIER AMPS-24 ADDRESSABLE POWER SUPPLY 120VAC NOTIFIER SBB-94 BACKBOX NOTIFIER BP2 4 BATTERY DRESS PLATE NOTIFIER BMP 1 BLANK MODULE DRESS PLATE NOTIFIER DR-B4 CSIZE DOOR W/WINDOWS NOTIFIER LCM-320 LOOP CONTROL MODULE NOTIFIER LEM-320 LOOP EXPANDER MODULE NOTIFIER UDAR2 UNIVERSAL DIGITAL COMM TRANSMITTER NOTIFIER DAA2-5025 120VAC DIGITAL AUDIO AMPLIFIER NOTIFIER EQB8B4 EQUIPMENT BACKBOX NOTIFIER EQDR-B4 DOORASSEMNBLY NOTIFIER NFS-LBB BATTERY BOX NOTIFIER LCD-160 TERMINAL&ACS MODE NOTIFIER RM-1 REMOTE MICROPHONE NOTIFIER DNR W/FSP-951R DUCT DETECTOR W/SMOKE DETECTOR NOTIFIER FSP-951 W/B300-6 SMOKE DETECOR W/BASE NOTIFIER FST-951R W/B300-6 RATE OF RISE THERMAL SENSOR W/BASE NOTIFIER FCM-1 CONTROL MODULE NOTIFIER FRM-1 RELAY MODULE NOTIFIER FDM-1 DUAL MONITOR MODULE NOTIFIER FMM-1 MONITOR MODULE NOTIFIER FMM-101 MINI MONITOR MODULE NOTIFIER ISO-X SLC LOOP ISOLATOR MODULE NOTIFIER NBG-12LX DUAL ACTION PULL STATION NOTIFIER NBG-12LOB DUAL ACTION PULL STATION-OUTDOOR POTTER RTSO TROOM TEMPERATURE SWITCH POTTER PSN-106 10A POWER SUPPLY SYSTEM SENSOR 5623 HEAT DETECTOR SYSTEM SENSOR DST1 SAMPLING TUBE SYSTEM SENSOR SCWLED STROBE,CEILING MOUNT SYSTEM SENSOR SPCWL SPEAKER,CEILING MOUNT SYSTEM SENSOR SPSCWLED SPEAKER STROBE,CEILING MOUNT SYSTEM SENSOR SPSWLED SPEAKER STROBE,WALL MOUNT SYSTEM SENSOR SPWL SPEAKER,WALL MOUNT SYSTEM SENSOR SPSCWKLED OUTDOOR SPEAKER STROBE,CEILING MOUNT SYSTEM SENSOR SPSWKLED OUTDOOR SPEAKER STROBE,WALL MOUNT SYSTEM SENSOR RTS151 REMOTE TEST SWITCH SYSTEM SENSOR SSM24-10 ALARM BELL HONEYWELL HWF2V-COM CELL COMMUNICATOR POWER SONIC PS-12330 12V,33 AH BATTERY POWER SONIC PS-1270 12V,7 AH BATTERY DN-7070:P•A-10 N FS2.3030 N OT I F I E R° Intelligent Addressable 0 Fire Alarm System by Honeywell Intelligent Fire Alarm Control Panels General The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- • - cations.The NFS2-3030 is part of the ONYX Series of prod- - 3 ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display(LCD) presents vital information to operators concerning a fire situa- tion,fire progression,and evacuation details. A host of other options are available, including single-or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- 70700ov9.jpg ucts for challenging environments;wireless fire protection;and many additional options. NFS2-3030 (left) Features and NFS2-3030 with DVC audio option (right) • Certified for seismic applications when used with the appro- priate seismic mounting kit. • With built-in Degraded Mode operation,the system is capa- • Approved for Marine applications when a marine-listed ver- ble of general alarm if a fire alarm condition is present even sion is used with marine-listed compatible equipment. See if the central processing unit(CPU)fails. DN-60688. • Weekly Occupancy Schedules allow changing sensitivity by • Complies with UL 2572 Mass Notification Systems (NFS2- time of day and day of week. 3030 version 20 or higher). • EIA-485 annunciators, including custom graphics. • One to ten isolated intelligent Signaling Line Circuits (SLC) • History file with 4000-event capacity in nonvolatile memory, Style 4,6 or 7. plus separate 1000-event alarm-only file. • Wireless fire protection using SWIFT Smart Wireless Inte- • Advanced history filters allow sorting by event, time, date, grated Fire Technology. See DN-60820. or address. • Up to 159 detectors and 159 modules per SLC;318 devices • Alarm Verification selection per point, with automatic per loop/3,180 per FACP or network node. counter. —Detectors can be any mix of ion, photo, thermal, or multi- • Autoprogramming and Walk Test reports. sensor; wireless detectors are available for use with the • Multiple central station communication options: FWSG. —Standard UDACT —Modules include addressable pull stations, normally open —Internet contact devices,two-wire smoke detectors, notification,or —Internet/GSM relay; wireless modules are available for use with the FWSG. Positive Alarm Sequence(PAS) Presignal. • Large 16 line, 640 character LCD backlit display or use • Silence Inhibit and Auto Silence timer options. display-less as a network node. • Field-programmable on panel or on PC, with VeriFire Tools • Network options: program,also check,compare. —High-speed network for up to 200 nodes (NFS2-3030, • Non-alarm points for lower priority functions. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, • Remote ACK/Signal Silence/System Reset/Drill via monitor ONYXWorks, NFS-3030, NFS-640, and NCA). modules. —Standard network for up to 103 nodes (NFS2-3030, • Up to 1000 powerful Boolean logic equations. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, . Supports SCS Series smoke control system in both HVAC ONYXWorks, NCS, NFS-3030, NFS-640, NCA,AFP-200, and FSCS modes. AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes FM6320 approved Gas Detection System with FMM-4-20 when DVC-EM is used in network paging. module and any FM listed gas detector. • Built-in Alarm,Trouble, Security,and Supervisory relays. • EIA-232 printer port. • VeriFire8 Tools online/offline program option. EIA-485 annunciator port. DN-7070:P•3/8/17—Page 1 of 8 640-CHARACTER DISPLAY FEATURES -Acclimate PIusTM-0.5 to 4.0%/foot obscuration. • Backlit,640-character display. -IntelliQuad-1.0 to 4.0%/foot obscuration. • Program keypad:full QWERTY keypad. -IntelliQuadTM PLUS-1.0 to 4.0%/foot obscuration • Up to nine users, each with a password and selectable • Drift compensation (U.S. Patent 5,764,142). access levels. • Multi-detector algorithm involves nearby detectors in alarm • 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- decision (U.S. Patent 5,627,515). rity; Supervisory; System Trouble; Other Event; Signals . Automatic detector sensitivity testing (NFPA-72 compliant). Silenced; Point Disabled;CPU Failure; Controls Active. . Maintenance alert(two levels). • Membrane Switch Controls: Acknowledge; Signal . Self-optimizing pre-alarm. Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 lines x 40 characters) Programmable activation of sounder/relay bases during • alarm or pre-alarm. with long-life LED backlight. • Read Status displays the level of detector cleanliness. FLASHSCANO INTELLIGENT FEATURES FSL-751 VIEW® (VERY INTELLIGENT EARLY WARNING) • Polls up to 318 devices on each loop in less than two SMOKE DETECTION TECHNOLOGY seconds. • Activates up to 159 outputs in less than five seconds. • Advanced ONYX intelligent sensing algorithms differentiate • Multicolor LEDs blink device address during Walk Test. between smoke and non-smoke signals (U.S. Patent 5,831,524). • Fully digital, high-precision protocol (U.S. Patent . Addressable operation pinpoints the fire location. 5,539,389). • Early warning performance comparable to the best aspira- • Manual sensitivity adjustment—up to nine levels. tion systems at a fraction of the lifetime cost. • Pre-alarm ONYX intelligent sensing—up to nine levels. • Sensitivity levels: -Ion-0.5 to 2.5%/foot obscuration. -Photo-0.5 to 2.35%/foot obscuration. -Laser(VIEVO)-0.02 to 2.0%/foot obscuration. Sample System Options SLC Intelligent Loop -DEVICES �; o0 oa 0 0 t- VJ FWSG o .a FAPT-851 NBG-12LX T XP6/10 1/0 Modules NUp to 32 FSL-751 LCD-160 FSP-851 FMM-1 FRM-1 LCD2-80 remote FSA-8000 displays ...etc. IDC Relay Contact EIA-485 EIA-485 3072 annunciator/control points e� ®AAB®A A B ® ■ ■ CPU2-3030D 0 o display or '• '• '• CPU2-3030ND Nil. El ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Dual phone 0 lines to 3 Optional 2048-point UDACT Central Station EIA-232 0 N FS2-3030 Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the ROP port, or LCO2-80 in terminal mode, but not both at the same time. Page 2 of 8—DN-7070:P•3/8/17 FAPT 851 ACCLIMATE PI.USTM LOW-PROFILE INTELLIGENT • 35 watt,50 watt,75 watt,and 100/125 watt digital amplifiers MULTI-SENSOR (DAA2/DAX series and DS series). • Detector automatically adjusts sensitivity levels without • Solid state message generation. operator intervention or programming. Sensitivity increases • Hard-wired voice control module options. with heat. • Firefighter telephone option. • Microprocessor-based technology; combination photo and . 30-to 120-watt analog amplifiers(AA Series). thermal technology. • Backup tone generator and amplifier option. • Low-temperature signal at 40oF 50F(4.44°C 2.770C). FSC-851 INTELLIOUAD FlashScanO Exclusive ADVANCED MULTI-CRITERIA DETECTOR World-Leading Detector Protocol • Detects all four major elements of a fire (smoke, heat, CO, At the heart of the NFS2-3030 is a set of detection devices and and flame). device protocol—FlashScan(U.S. Patent 5,539,389). FlashS- • Automatic drift compensation of smoke sensor and CO cell. can is an all-digital protocol that gives superior precision and • High nuisance-alarm immunity high noise immunity. INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, FSA- As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- 20000 ANv FSA-20000P tion of the time required by competitive protocols. This high • Connects directly to the SLC loop of compatible ONYX speed also allows the NFS2-3030 to have the largest device series panels. per loop capacity in the industry — 318 points — yet every • Provides five event thresholds that can be individually pro- input and output device is sampled in less than two seconds. grammed with descriptive labels for control-by-event pro- The microprocessor-based FlashScano detectors have bicolor gramming; uses five detector addresses. LEDs that can be coded to provide diagnostic information, • Uses patented particle separator and field-replaceable filter such as device address during Walk Test. to remove contaminants. • Advanced algorithms reject common nuisance conditions ONYX Intelligent Sensing • FSA-5000 covers 5,000 square feet through one pipe. ONYX Intelligent Sensing is a set of software algorithms that • FSA-8000 covers 8,000 square feet through one pipe. provide the NFS2-3030 with industry-leading smoke detection • FSA-20000 covers 28,800 square feet through one to four capability. These complex algorithms require many calcula- pipes. tions on each reading of each detector,and are made possible by the very high-speed microcomputer used by the NFS2- • FSA-20000P covers 28,800 square feet through one to four 3030. addressable pipes. Supports addressable pipes to pinpoint location of alarm events. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual FCO-851 INTELLIOUADTM PLUS smoke, and resist false alarms, even as dirt accumulates. It ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR reduces maintenance requirements by allowing the system to • Detects all four major elements of a fire. automatically perform the periodic sensitivity measurements • Separate signal for life-safety CO detection. required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by • Optional addressable sounder base for Temp-3 (fire) or electrical interference. Temp-4(CO)tone. Automatic drift compensation of smoke sensor and CO cell. Maintenance Warnings. When the drift compensation per- • formed for a detector reaches a certain level,the performance • High nuisance-alarm immunity. of the detector may be compromised, and special warnings FMM-4-20 GAS DETECTION MODULE are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation • Interface to industry-standard linear scale 4-20 mA sensors. that is near but below the allowed limit; (3) Maintenance • Five programmable thresholds. Urgent,indicative of dust accumulation above the allowed limit. • FM Approved, Class 6320 (Stationary Gas Sensors/ Sensitivity Adjust. Nine sensitivity levels are provided for Detectors). alarm detection. These levels can be set manually, or can SWIFT WIRELESS change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- • Self-healing mesh wireless protocol. mined levels of alarm. Pre-alarm operation can be latching or • Each SWIFT Gateway supports up to 50 devices: 1 wireless self-restoring,and can be used to activate special control func- gateway and up to 49 SWIFT devices. tions. • Up to 4 wireless gateways can be installed with overlapping Self-Optimizing Pre-Alarm. Each detector may be set for network coverage. "Self-Optimizing"pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog RELEASING FEATURES readings over a long period of time, and setting the pre-alarm • Ten independent hazards. level just above these normal peaks. • Sophisticated cross-zone(three options). Cooperating Multi-Detector Sensing. A patented feature of • Delay timer and Discharge timers(adjustable). ONYX Intelligent Sensing is the ability of a smoke sensor to • Abort(four options). consider readings from nearby sensors in making alarm or pre-alarm decisions.Without statistical sacrifice in the ability to VOICE AND TELEPHONE FEATURES resist false alarms, it allows a sensor to increase its sensitivity • Up to eight channels of digital audio. to actual smoke by a factor of almost two to one. DN-7070:P•3/8/17—Page 3 of 8 Field Programming Options LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- Autoprogram is a timesaving feature.The FACP"learns"what ers for a total of ten SLCs. See DN-6881. devices are physically connected and automatically loads them in the program with default values for all parameters. LEM-320: Loop Expander Module. Expands an LCM-320.See Requiring less than one minute to run, this routine allows the DN-6881. user to have almost immediate fire protection in a new installa- SAMPLE SYSTEM: Four-loop NFS2-3030 with display: tion, even if only a portion of the detectors are installed. CPU2-30301), DP-DISP, two B1VIP-1s, CHS-M3, two LCM- Keypad Program Edit. The NFS2-3030, like all NOTIFIER 320s, two LEM-320s, AMPS-24, SB8-A4, DR-A4, 13P2-4, BB- intelligent panels, has the exclusive feature of program cre- 100, batteries. ation and editing capability from the front panel keypad, while NETWORKING OPTIONS continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its NCA-2: Network Control Annunciator, 640 characters. An own program, including control-by-event links to other points. alternate primary display for CPU2-3030 can be provided by This allows the program to be entered with independent per- the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary point segments,while the NFS2-3030 simultaneously monitors display enables non-English languages. On network systems other(already installed) points for alarm conditions. (two or more networked fire panel nodes), one network display (either NCA-2, NCS,or ONYXWorks)is required for every sys- VERIFIRE®TOOLS tem. On network systems,the NCA-2 connects (and requires) VeriFire®Tools is an offline programming and test utility that a standard Network Communication Module or High-Speed can greatly reduce installation programming time, and Network Communication Module. Mounts in a row of FACP increase confidence in the site-specific software. It is Win- node or in two annunciator positions. Mounting options include dows®based and provides technologically advanced capabili- the DP-DISP, ADP-4B, or in an annunciator box, such as the ties to aid the installer. The installer may create the entire ABS-21D. In CAB-4 top-row applications, a DP-DISP and two program for the NFS2-3030 in the comfort of the office, test it, BMP-1 blank modules are required for mounting. Non-English store a backup file,then bring it to the site and download from versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, a laptop into the panel. NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For English ULC applications, order NCA-2C; for marine applica- Product Line Information tions,order NCA-2-M;for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX.See DN-7047. • "Configuration Guidelines"on page 4 NCM-W, NCM-F: Standard Network Communications Mod- • "Main System Components"on page 4 ules. Wire and multi-mode fiber versions available. See DN- • "Networking Options"on page 4 6861. • "Auxiliary Power Supplies and Batteries"on page 4 HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network • "Audio Options"on page 5 Communications Modules that can connect to two nodes. • "Compatible Devices, EIA-232 Ports"on page 5 Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. • "Compatible Devices, EIA-485 Ports"on page 5 "Compatible Intelligent Devices"on page 5 RPT W, RPT F, RPT WF: Standard-network repeater board • with wire connection (RPT-W), multi-mode fiber connection • "Enclosures,Chassis,and Dress Plates"on page 6 (RPT-F),or allowing a change in media type between wire and • "Other Options"on page 7 fiber (RPT-WF). Not used with high-speed networks. See DN- 6971. CONFIGURATION GUIDELINES Stand-alone and network s stems require a main display. On ONYXWorks: UL-listed graphics PC workstation,ONYXWorks yGUI software, and computer hardware. See ON-7046 for spe- single-FACP systems(one NFS2-30301)),the display option is cific part numbers. the CPU2-30301). On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- Works annunciation device is required. Options listed as GW-EM.)See DN-60499. follows. NWS-3: NOTI•FIRE•NETTM Web Server. See DN-6928. MAIN SYSTEM COMPONENTS CAP-GW: Common Alerting Protocol Gateway. See DN- CPU2-303011): NFS2-3030 Primary Display. CPU2-3030D 60756. snips Witil <eypad/display installed; includes 640-character VESDA-HLI-GW:VESDAnet high-level interface gateway.See backlit LCD display, QWERTY programming and control key- DN-60753. pad. CPU2-3030 is a central processing unit and requires an LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic AMPS-24(E) power supply. For English ULC applications, use and high-speed NOTI•FIRE•NET networks through the NFN CPU2-3030DC. Non-English versions are available: CPU2- Gateway.See DN-60679. 3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2 3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- OAX2-24V: UL listed LED sign, used with LEDSIGN GW. See DN 60679. 3030D-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- AUXILIARY POWER SUPPLIES AND BATTERIES tions order CPU2-3030D-M and the appropriate KP-KIT-XX. AMPS-24(E): One required for each NFS2-3030.Addressable (See DN-60688.) power supply and battery charger with two 24 VDC outputs. CPU2-3030ND: CPU2-3030 without display. Non-English ver- Addressable by any FlashScan® or CLIP mode FACP. sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, Charges 7 to 200 AH batteries. Occupies up to five addresses CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, on an SLC, depending on configuration. Primary input power CPU2-3030ND-SP,CPU2-3030ND-TC. for panel. See DN-6883. APS2-6R:Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and Page 4 of 8—DN-7070:P•3/8/17 transfer relay, and overcurrent protection. Mounts on two of DAA Series Digital Audio Amplifiers: Legacy DAA Series four positions on a CHS-4L or CHS-4 chassis. See DN-5952. amplifiers are compatible with DVC systems running SR4.0. ACPS-610: 6.0 A or 10.0 A addressable charging power sup- For specific information on DAA-50 series amplifiers, refer to ply. See DN-60244. DN-7046. For information on DAA-7525 Series, refer to DN- 60257. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger.See DN-6927. COMPATIBLE DEVICES, EIA-232 PORTS BAT Series: Batteries.AMPS-24 uses two 12 volt,7 to 200 AH PRN-7: 80-column printer.See DN-60897 batteries. See DN-6933. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. AUDIO OPTIONS See DN-3260. NOTE:See"Enclosures,Chassis,and Dress Plates"on page 6 for DPI-232: Direct Panel Interface, specialized modem for mounting hardware. extending serial data links to remotely located FACPs and/or DVC-EM: Digital Voice Command,digital audio processor with peripherals. See DN-6670. message storage for up to 32 minutes of standard quality (4 COMPATIBLE DEVICES, EIA-485 PORTS minutes at high quality)digital audio.See DN-7045. ACM-24AT: ONYX Series ACS annunciator-up to 96 points DVC-RPU: Digital Voice Command Remote Paging Unit for of annunciation with Alarm or Active LED, Trouble LED, and use with DVC-EM. Includes the keypad/display. See DN- switch per circuit. Active/Alarm LEDs can be programmed (by 60726. powered-up switch selection) by point to be red, green, or yel- DS-DB: Digital Series Distribution Board, provides bulk ampli- low;the Trouble LED is always yellow.See DN-6862. fication capabilities to the DVC-EM while retaining digital audio AEM-24AT: Same LED and switch capabilities as ACM-24AT; distribuition capabilities. Can be configured with up to four DS- expands the ACM-24AT to 48,72,or 96 points.See DN-6862. AMPs, supplying high-level risers spread throughout an instal- ACM-48A: ONYX®Series ACS annunciator-up to 96 points lation. See DN-60565. of annunciation with Alarm or Active LED per circuit. Active/ DVC-KD: DVC-EM keypad for local annunciation and controls; Alarm LEDs can be programmed(by powered-up switch selec- status LEDs and 24 user-programmable buttons. See DN- tion) in groups of 24 to be red,green,or yellow. Expandable to 7045. 96 points with one AEM-48A. See DN-6862. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS AEM-48A: Same LED capabilities as ACM-48A; expands the requires DS-XF70V step-up transformer. Digital Series Ampli- ACM-48A to 96 points. See DN-6862. fier, part of the DS-DB system. See DN-60663. ACM-8R: Remote Relay Module with eight Form-C contacts. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for Can be located up to 6,000 ft. (1828.8 m) from panel on four DVC-EM, DS-DB distribution board, and DAA2/DAX Series wires. See DN-3558. amplifiers. See DN-60633. LCD-160: Liquid Crystal Display annunciator, 160-character DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- backlit. Can store character sets for multiple languages. LCD- bly with power supply; includes chassis.See DN-60556. 160C is used for ULC applications. See DN-6940. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier LCD2-80: Terminal and ACS mode. 80-character, backlit LCD assembly with power supply;includes chassis.See DN-60556. display. Mounts up to 6,000 ft. (1828.8 m)from panel. Up to 32 DAA2-7525(E):75W,25 Vrms digital audio amplifier assembly Per FACP.See LCO2-80(DN-60546). with power supply; includes chassis. See DN-60556. SCS Series: Smoke control station; eight (expandable to 16) DAX-3525(E): 35W,25 Vrms Digital Audio Amplifier assembly circuits. See DN-4818. with power supply, includes chassis.See DN-60561. TM-4: Transmitter Module. Includes three reverse-polarity cir- DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- cuits and one municipal box circuit. Mounts in panel module bly with power supply, includes chassis.See DN-60561, position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. DAX-5025(E): 50W,25 Vrms Digital Audio Amplifier assembly UDACT-2: Universal Digital Alarm Communicator Transmitter, with power supply, includes chassis.See DN-60561. 636 channel. See DN-60686, DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- UZC-256: Programmable Universal Zone Coder provides pos- bly with power supply, includes chassis.See DN-60561, itive non-interfering successive zone coding. Microprocessor- TELH-1: Firefighter's Telephone Handset for use with the controlled, field-programmable from IBMR-compatible PCs DVC-EM when mounted in the CA-2 chassis.See DN-7045. (requires optional programming kit). Mounts on a CHS-4 CMIC-1: Microphone used with DVC/DVC-EM. Included with series chassis within NFS2-3030. CA-2 chassis assembly. See DN-7045, COMPATIBLE INTELLIGENT DEVICES RM-1/RM-1SA: Remote microphone assemblies, mount on NOTE: "A"suffix indicates ULC-Listed model. ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1 SA) stand-alone cabinets.See DN-6728. FWSG Wireless SWIFT Gateway:Addressable gateway sup- ports wireless SLC devices. Not appropriate for ULC applica- AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier tions.See DN-60820. and audio input supervision, backup input, and automatic swi- tchover, power supply,cables. See DN-3224. FSA-5000: Intelligent FAASTO XS Fire Alarm Aspiration Sens- ing Technology. Intelligent aspirating smoke detector for appli- AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 cations up to 5,000 sq.ft. For Canadian applications, order Vrms.AA-100 is 100 watts, 70.7 Vrms.The amplifier contains FSA-5000A. an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox(consumes one row). Includes audio input and ampli- FSA-8000: Intelligent FAASTO XM Fire Alarm Aspiration fied output supervision, backup input, and automatic switcho- Sensing Technology. Intelligent aspirating smoke detector for ver to backup tone.See DN-3224, applications up to 8,000 sq.ft. For Canadian applications,order FSA-8000A.See DN-60792. DN-7070:P•3/8/17-Page 5 of 8 FSA-20000: Intelligent FAASTO XT Fire Alarm Aspiration FMM-4-20: FlashScan 4-20 mA protocol monitor module. See Sensing Technology. Intelligent aspirating smoke detector for DN-60411. applications up to 28,800 sq.ft. For Canadian applications, FCM-1(A): FlashScan control module. See DN-6724. order FSA-20000A.See DN-60849, FSA-20000P FAAST®XT PRO Intelligent Aspiration Detector For FCM-I-REL(A): FlashScan releasing control module. See DN- applications up to 28,800 sq.ft. (2601 sq. m.)through one to four 60390. addressable pipes.See DN-60792 FTM-1(A): Firephone Telephone Module connects a remote FSB-200(A): Intelligent beam smoke detector.See DN-6985. firefighter telephone to a centralized telephone console. Reports status to panel.Wiring to jacks and handsets is super- FSB-200S(A): Intelligent beam smoke detector with integral vised. See DN-6989. sensitivity test.See DN-6985. FRM-1(A): FlashScan relay module.See DN-6724. FSC-851(A): FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-60412. FDRM-1(A): FlashScan dual monitor/dual relay module. See DN-60709. FCO-851(A): FlashScan IntelliQuad PLUS Advanced Multi-Cri- teria Fire/CO Detector. See DN-60689. NBG-12LX: Manual pull station,addressable. See DN 6726. FSI-851(A): Low-profile FlashScan ionization detector. See ISO-X: Isolator module. See DN-2243, DN-6985. ISO-6: Six Fault isolator module. For Canadian applications FSP-851(A): Low-profile FlashScan photoelectric detector.See order ISO-6A. See DN-60844. DN-6935. XP6-C(A): FlashScan six-circuit supervised control module. FSP-851R(A): Low-profile intelligent photoelectric sensor, See DN-6924, remote test capable. For use with DNR(W). See DN-6935. XP6-MA(A): FlashScan six-zone interface module; connects FSP-851T(A): Low-profile FlashScan photoelectric detector intelligent alarm system to two-wire conventional detection with 135°F(57°C)thermal. See DN-6935. zone. See DN-6925, FST-851(A):: FlashScan thermal detector 135°F (57°C). See XP6-R(A): FlashScan six-relay (Form-C) control module. See DN-6936. DN-6926. FST-851 R(A): FlashScan thermal detector 135°F (57°C) with XP10-M(A): FlashScan ten-input monitor module. See DN- rate-of-rise. See DN-6936. 6923. FST-851 H(A): FlashScan 190°F (88°C) high-temperature ther- SLC-IM: SLC integration module, for VESDAnet detectors. mal detector. See DN-6936. See DN-60755. FAPT851(A): FlashScan Acclimate PIusTM low-profile multi- ENCLOSURES,CHASSIS,AND DRESS PLATES sensor detector.See DN-6937. CAB-4 Series Enclosure: NFS2-3030 mounts in a standard FSL-751(A): FlashScan VIEW laser photo detector. See DN- CAB-4 Series enclosure (available in four sizes, "A" through 6886. "D"). Backbox and door ordered separately; requires BP24 battery plate. A trim ring option is available for semi-flush DNR(A): InnovairFlex low-flow non-relay duct-detector housing mounting. See DN-6657, (order FSP-851 separately). Replaces FSD-751 PUFSD- 751 RPL. See DN-60429. EQ Series Cabinets: EQ series cabinets will house amplifiers, DNRW(A): Same as above with NEMA 4 rating, watertight. power supplies, battery chargers and control modules. EQ See DN-60429. cabinets are available in three sizes, "B"through"ID". See DN- 60229. B224RB: Low-profile relay base.See DN-60054. CAB-BM Marine System: Protects equipment in shipboard B224BI: Isolator base for low-profile detectors. See DN- and waterfront applications. Order CPU2-3030D-M; for non- 60054. English marine applications order CPU2-3030D and appropri- B210LP: Low-profile base. Standard U.S. style. Replaces ate KP-KIT-XX. Also order BB-MB for systems using 100 AH B710LP. See DN-60054. batteries. For a full list of required and optional equipment,see DN-60688. B501(A): European-style,4" (10.16 cm)base.See DN-60054. CHS-M3: Mounting chassis for CPU2-3030. One required for B20OS: Intelligent programmable sounder base, capable of each CPU2-3030D/3030ND. producing a variety of tone patterns including ANSI Temporal 3.Compatible with sychronization protocol. See DN-60054. CA-2: Chassis for control panel when p two r is used with firefighter's telephone. Mounts in the top two rows of a B20OS-LF: Low-frequency version of B200S. See DN-60054. CAB-4 series enclosure. B200SCOA: Based on B200SA, with added CO detector DP-DISP: Dress panel for top row in cabinet with CPU2- markings in English/French. For Canadian applications only. 3030D installed. B200SR: Sounder base, Temporal 3 or Continuous tone. See DP-1 B: Blank dress panel. Provides dead-front panel for DN-60054. unused tiers; covers DAA2/DAX series or AA-series amplifier. B200SR-LF: Low-frequency version of B200SR. See DN- See DN-7046. 60054. CHS-131­11: Battery chassis; holds two 12.0 AH batteries. FMM-1(A):: FlashScan monitor module.See DN-6720. Mounts on the left side of DAA2 chassis.See DN-7046. FDM-1(A): FlashScan dual monitor module.See DN-6720. CA-1:Chassis,occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD FZM-1(A): FlashScan two wire detector monitor module. See DN-6720. (optional); and the right side houses a CMIC-1 microphone and its well (optional).See DN-7045. FMM-101(A): FlashScan miniature monitor module. See DN- CA-2:Chassis assembly,occupies two tiers of a CAB-4 Series 6720. enclosure.The left side accommodates one DVC-EM mounted Page 6 of 8-DN-7070:P•3/8/17 on a half-chassis and one NFS2-3030 or NCA-2 mounted on a ABF-4B Annunciator Flush Box half-chassis. The right side houses a microphone/handset ABS-iTB(C)Annunciator Surface Box well.The CA-2 assembly includes CMIC-1 microphone.ADDR ABS-1 B(C)Annunciator Surface Box Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-D4 ABS-2B Annunciator Surface Box (below). ABS-2D(C)Annunciator Surface Box ADDR-B4:Two-tier-sized door designed for use with the CA-2 ABS-4D(C)Annunciator Surface Box chassis configuration. ADDR Series doors are similar to CAB- SEISKIT CAB: Seismic mounting kit. Required for seismic- 4 Series "DR" doors, but a clear window space exposes the certified applications with NFS2-3030 and other equipment top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox mounted in CAB-4 Series Enclosures. Includes battery bracket with the ADDR-134.See ON-7045, DN-6857. for two 26 AH batteries. ADDR-C4:Three-tier-sized door designed for use with the CA- SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery 2 chassis configuration. ADDR Series doors are similar to bracket for two 55 AH batteries. CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 OTHER OPTIONS backbox with the ADDR-C4.See DN-7045, ON-6857. 411: Slave digital alarm communicator.See ON-6619. ADDR-D4: Four-tier-sized door designed for use with the CA-2 411 UDAC: Digital alarm communicator. See DN-6746. chassis configuration. ADDR Series doors are similar to CAB- IPDACT-2, IPDACT Internet Monitoring Module: Connects 4 Series "DR" doors, but a clear window space exposes the to primary and secondary DACT telephone output ports for top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox internet communications over customer-provided Ethernet with the ADDR-D4.See ON-7045, DN-6857. connection. Requires compatible Teldat VisorALARM Central DPA-1: Dress panel, used with the CA-1 chassis when config- Station Receiver.Can use DHCP or static IR See DN-60408. ured with a DVC-EM, DVC-KD,and CMIC-1. See DN-7045. IPCHSKIT: IP Communicator Chassis Mounting Kit. For DPA-2: Dress Panel used with the CA-2 chassis assembly. mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 DPA-1A4: Dress panel, used with the CA-1 chassis when the series chassis. Use IPENC for external mounting applications. CMIC-1 is not used. Provides mounting options on right two IPSPLT:Y-adapter option allow connection of both panel dialer bays for two ACS annunciators, or for blank plates. See DN- outputs to one IPDACT-2/2UD cable input. 7045. IPENC: External enclosure for IPDACT, includes IPBRKT ADP-46: Annunciator dress plate. Mounts in rows 2, 3 or 4 of mounting bracket; Red;for black,order IPENC-B. a CAB-4 series enclosure. Used with ACS series annuncia- IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tors. tor. Provides selectable configurable paths:cellular only, IP only, BMP-1: Blank module for unused module positions. or IP primary with cellular backup. Connects to the primary and DP-1 B: Blank dress panel. Provides dead-front panel for secondary ports of a DACT. For Canadian applications order unused tiers;covers DAA2/DAX series or AA-series amplifier. IPGSM-4GC.See 01-1-60769. NOTE: For other options including compatibility with retrofit equip- BP2-4: Battery plate, required. ment,refer to the panel's installation manual,the SLG manual,and CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 the Device Compatibility Document. amplifiers. CHS-4N: Chassis for mounting up to four APS-6Rs. System Specifications CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. SYSTEM CAPACITY Mounts up to six modules in any CAB-4 series row. . Intelligent Signaling Line Circuits...........1 expandable to 10 NFS-LBB: Battery Box. The NFS-LBB is used to mount up to . Intelligent detectors..........................................159 per loop two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x Addressable monitor/control modules..............159 per loop 14"(356 mm) high x 7.75" (197 mm)deep. Door:24.125" (613 mm)wide x 14.25"(362 mm)high;door adds 0.0625"(approx. . Programmable software zones.............................over 2000 1.6 mm)to depth. • ACS annunciators BACKBOXES per CPU2-3030.......................32 address x 64 or 96 points NOTE:"C"suffix indicates ULG-Listed model. NOTE: The CPU2-3030 can support up to 96 annunciator address points per AGM-24AT/-48A. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power SPECIFICATIONS supply, if needed. 30" (76.20 cm)wide x 25" (63.50 cm)high x Primary Input Power: 7.5" (19.05 cm)deep;depth includes door. -AMPS-24: 110-120 VAC, 50/60 Hz,4.5 A maximum. BB-200: Backbox for batteries and power supplies. Holds up -AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. to four 100 AH batteries (200 AH capacity) and power supply. 30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) DC Output: deep;depth includes door. -Main 24 VDC: Up to 5.0 A BB-UZC: Backbox for housing the UZC-256 for applications -Aux 24 VDC: Up to 5.0 A where the UZC will not fit in panel enclosure. Black; for red, -5 VDC: Up to 0.15 A. order BB-UZC-R. See ON-3404. Current draw(Standby/Alarm): ABF-1 B(C)Annunciator Flush Box -CPU2-3030D board:0.340 A. ABF-1 DB(C)Annunciator Flush Box with Door. UL/ULC Listed. -CPU2-3030ND board:0.120 A. ABF-2B Annunciator Flush Box -LCM-320:0.130 A. ABF-2DB(C)Annunciator Flush Box with Door -LEM-320:0.100 A. DN-7070:P•3/8/17-Page 7 of 8 —AMPS-24(E)":0.13 A. STANDARDS (Draws power from secondary power source only.) The NFS2-3030 complies with the following UL Standards and NOTE: See AMPS-24(E) Manual 51907 for a complete current NFPA 72, International Building Code (IBC), and California draw calculation sheet and details of input and output values. Building Code(CBC) Fire Alarm Systems requirements: Battery charger range:7 AH—200 AH. Use separate cabinet . UL 864(Fire). for batteries over 26 AH. • UL 1076(Burglary). Float Rate:27.6 V. • UL 2572 (Mass Notification Systems). (NFS2-3030 version SHIPPING WEIGHT 20 or higher) • CPU2-3030D:5.95 lb(2.70 kg). • ULC-S527-11 Standard for the Installation of Fire Alarm Sys- tems. • CPU2-3030ND:2.90 lb(1.32 kg). • LOCAL (Automatic, Manual, Waterflow and Sprinkler TEMPERATURE AND HUMIDITY RANGES Supervisory). This system meets NFPA requirements for operation at 0 — • AUXILIARY (Automatic, Manual and Waterflow) (requires 49°C/32 — 120°F and at a relative humidity 93% 2% RH TM-4). (noncondensing) at 32°C 2°C (90oF 3°F). However, the . REMOTE STATION (Automatic, Manual, Waterflow and useful life of the system's standby batteries and the electronic Sprinkler Supervisory) (requires TM-4). components may be adversely affected by extreme tempera- • PROPRIETARY (Automatic, Manual, Waterflow and Sprin- ture ranges and humidity. Therefore, it is recommended that kler Supervisory). Not applicable for FM. this system and its peripherals be installed in an environment . EMERGENCY VOICE/ALARM. with a normal room temperature of 15—27°C/60—80°F. OT, PSDN (Other Technologies, Packet-switched Data Net- AGENCY LISTINGS AND APPROVALS work). These listings and approvals apply to the modules specified in . IBC 2012,IBC 2009,IBC 2006, IBC 2003,IBC 2000(Seis- this document. In some cases,certain modules or applications mic). may not be listed by certain approval agencies, or listing may • CBC 2007(Seismic). be in process. Consult factory for latest listing status. • UL Listed:S635. • ULC Listed: S527-11. • MEA:232-06-E. • Fire Dept.of New York:COA#6211. • CSFM: 7165-0028:0224(Commercial). • FM Approved. • FM6320 Approved.Class 6320 for Gas Detection. • City of Chicago. • City of Denver. • Singapore Productivity and Standards Board(PSB). • CCCF listed. • Fire Services Department(Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in"Product Line Information.)Spe- cific connections and requirements for those components are described in the installation document, PN 54756.When these requirements are followed, systems are approved by the fol- lowing agencies: • US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). • Lloyd's Register 1 1/60001 3(ENV 3 category). • American Bureau of Shipping(ABS)Type Approval. NOTE: For information on marine applications,see ON-60688. IntelliQuadTM, NOTI•FIRE•NETTM, ONYXWorksTm and SWIFTTm are all trademarks; and Acclimate PIusTM, FlashScand, Intelligent FAAST®, NOTIFIER®, ONYX®, VeriFire® Tools, and VIEW® are all registered trademarks of Honeywell International Inc. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS country of Origin:USA For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 8 of 8—DN-7070:P•3/8/17 DN-6883:B AMPS-24/E NOT 1 F 1 E R° Power Supply 0 for the NFS-3030, NFS2-3030 and NCA-2 by Honeywell CatallogSection General NOTIFIER's AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan@ or CLIP (Classic Loop Interface Protocol) i ty mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel -- (FACP). It can also be used as the primary power supply for QeAZAn000a the NCA-2 Network Control Annunciator. ; VOl TA0E8 ®GAOL—Of PoWERCAx K CONNE—D TO TI ® • CONINOL NR. IA{Li948GE5 Of PoN'ER xEfORE SERYKixO. Features • Addressable by NFS-3030/NFS2-3030 FACP. • Selectable charging current charges 7 AH to 200 AH batter- �,f • Isolated Signaling Line Circuit(SLC)interface. "we`•�� ��ty • Trouble bus input for use with normally-open dry contacts or open-collector circuit. '] • USB Type B connector for programming installation param- i'ti �" is eters. ���� � � 0 0� • Brownout detection. • Battery/battery charger supervision. t • Secondary Power Auxiliary Outputs:24V @ 0.5A and 5V @ 0.15A. • AC loss detection and AC loss delay reporting. • Mounts in a CAB-4 Series enclosure, EQ Cabinet Series enclosure, BB-25, BB-100, or BB-200 Battery Backbox. Agency Listings and Approvals Specifications These listings and approvals apply to the AMPS-24/E power supply. In some cases, certain modules may not be listed by • C) power: certain approval agencies, or listing may be in process. Con- AMPS24 110-120 VAC 50/60 Hz input, 5 A maximum; sult factory for latest listing status. 220-240 VAC 50/60 Hz input,2.5 A maximum. • MAIN 24V Output - filtered power-limited power. Refer to UL: S635 table for configuration/current information. • ULC: CS118 Charger Setting/ Main 24V(TB 1 on "Total AUX 24V(TB3 on Main • City of Chicago Battery Size Main Control Unit) Control Unit with TB2 on CPS- • City of Denver Max.Current 24)Max.Current • MEA:345-02-E 1A/7-26AH Bat- teries 5A 3A • CSFM: 7165-0028:224 2A/12-60AH Bat- 5A 3A • FM:Approved teries • FDNY:#6026 5A/55-200AH Configuration 1 5A OA Configuration 3A 1A Product Line Information Disabled 5A 5A AMPS-24:Addressable power supply/battery charger "Maximum current for all AUX 24 volt outputs.Note that TB2 on CPS-24 is limited to 0.5A. AMPS-24E:Same as AMPS-24:220-240VAC operation • AUX 24V - provides filtered power-limited power for addi- tional components. Refer to table above for configuration/ current information. • Secondary power(battery)charging circuit: Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries. Selectable charging current: 1.0 A,2.0 A or 5.0 A. • Secondary power auxiliary outputs. • Wire sizes: 10 AWG(5.26 mm2)to 22 AWG (0.326 mm2). • Battery fuse(F2): 15 A,fast-acting. • Shipping Weight: 4.25 lb DN-6883:6•10/15/09—Page 1 of 2 FlashScanO is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6883:B•10/15/09 DN-6857:C2•G-190 CAB.4 Series Cabinets ONYX° Series Backboxes J N OT I F I E R with Locking Doors by Honeywell Peripheral Devices General All cabinets for NOTIFIER fire alarm control panels are fabri- cated from 16-gauge steel. The cabinet assembly consists of two basic parts: a backbox and a locking door. Cabinets are available in either black or red, with or without windows. The window model provides a tasteful combination to accent the decor of the finest lobby setting. • The key-locked door is provided with a pin-type hinge,two keys and the necessary hardware to mount the door to the — backbox. • The backbox has been engineered to provide ease-of- entry for the installer. Knockouts are positioned at numer- ous points to aid the installer in bringing a conduit into the enclosure with a minimum of hardship. • Right- or left-hand hinges, selectable in the field. Door opens 180°. • Cabinets are arranged in four standard sizes, A (one tier) through D (four tiers), plus a mini cabinet (AA, one tier without a battery compartment). See Ordering Information. a o • A trim ring option is available for semi-flush mounting. 0 • Chassis bridge available for assembling multiple CHS-4 chassis external to the backbox. NFS2-3030 and OVC in "C"sized CA13-4 cabinet • Certified for seismic applications when used with the appro- priate seismic mounting kit. DR-A4BR: Door assembly, solid door,one tier, RED, 15 lbs. Ordering Information SBB-A4: Backbox assembly,one tier, BLACK,21 lbs. A complete cabinet assembly consists of: a door, a backbox, SBB-A4R: Backbox assembly,one tier, RED,21 lbs. an optional battery plate, and an optional semi-flush trim ring. For each cabinet required,order one"DR"door and one"SBB" TR-A4: Accessory semi-flush-mount trim ring, one tier(open- backbox. The BP2-4 battery plate is required for each cabinet ing 24.062" [61.118 cm] W x 20.062" [50.958 cm] H), BLACK, assembly that mounts batteries and/or a power supply in the 2.5 lbs. lower position of the cabinet. The optional trim ring is an NOTE:Black trim rings are used with red or black cabinets. attractive"picture frame"-style black metal ring. BP2-4: Battery plate. Used to cover battery and power supply MINI "AA"SIZE, ONE TIER when lower position is used in backbox,3.10 lbs. DR-AA4: Door assembly, window, one tier (no battery com- TWO TIERS, "B"SIZE partment), BLACK, 9.8 lbs. DR-1134: Door assembly,window,two tiers, BLACK, 17.45 lbs. DR-AA4R: Door assembly, window, one tier (no battery com partment), RED, 9.8 lbs. DR-113413: Door assembly,window,two tiers, RED, 17.45 lbs. DR-AA413: Door assembly, solid door, one tier (no battery ADDR-134: Two-tier-sized door designed for use with a CA-2 compartment), BLACK. chassis mounted in the top rows. BLACK. DR-AA4113R: Door assembly, solid door, one tier (no battery ADDR-1134R:Two-tier-sized door designed for use with a CA-2 compartment), RED. chassis mounted in the top rows. RED. SBB-AA4: Backbox assembly, one tier (no battery compart- lbs. Door assembly, solid door, two tiers, BLACK, 18.80 ment), BLACK, 16.65 lbs. lbs. SBB-AA4R: Backbox assembly, one tier(no battery compart- DR-11346R: Door assembly, solid door, two tiers, RED, 18.80 ment), RED, 16.65 lbs. TR-AA4: Accessory semi-flush-mount trim ring, one tier (no SBB-B4 Backbox assembly,two tiers, BLACK,26.88 lbs. battery compartment). S13113-134R: Backbox assembly,two tiers, RED,26.88 lbs. NOTE:Black trim rings are used with red or black cabinets. TR-134:Accessory semi-flush-mount trim ring,two tiers(open- ing 24.062" [61.118 cm] W x 28.562" [72.548 cm] H), BLACK, 3 lbs. DR-A4: Door assembly,window, one tier, BLACK, 14.20 lbs. NOTE:Black trim rings are used with red or black cabinets. DR-AM Door assembly,window,one tier, RED, 14.20 lbs. 113132-4: Battery plate. Used to cover battery and power supply DR-A4113: Door assembly, solid door, one tier, BLACK, 14.30 when lower position is used in backbox,3.10 lbs. lbs. DN-6857:C2•6/19/2012—Page 1 of 6 THREE TIERS, "C"SIZE • UL Listed: S635 DR-C4: Door assembly,window,three tiers,BLACK,20.75 lbs. • ULC Listed: S635 DR-C413: Door assembly,window,three tiers, RED,20.75 lbs. • MEA: 317-01-E,345-02-E ADDR-C4:Three-tier-sized door designed for use with a CA-2 ' CSFM: 7165-0028:0243 (NFS2-640), 7165-0028:0224 chassis mounted in the top rows. BLACK. (NFS2-3030) ADDR-C413:Three-tier-sized door designed for use with a CA- ' FM approved 2 chassis mounted in the top rows. RED. • FDNY:COA#6085,COA#6098 DR-C4113: Door assembly,solid door,three tiers, BLACK,23.45 CAB-4 Series cabinets with SEISKIT-CAB comply with seismic lbs. requirements of IBC 2000,IBC 2003,IBC 2006,IBC2009,and CBC 2007. DR-C41313: Door assembly, solid door, three tiers, RED, 23.45 lbs. SBB-C4: Backbox assembly,three tiers, BLACK,32.60 lbs. SBB-C4R: Backbox assembly,three tiers, RED,32.60 lbs. TR-C4: Accessory semi-flush-mount trim ring, three tiers (opening 24.062" [61.118 cm] W x 37.187" [94.455 cm] H), BLACK, 3.50 lbs. NOTE:Black trim rings are used with red or black cabinets. BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox,3.10 lbs. FOUR TIERS, "D" SIZE DR-D4: Door assembly,window,four tiers, BLACK,23.95 lbs. DR-D4R: Door assembly,window,four tiers, RED,23.95 lbs. ADDR-D4: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. BLACK. ADDR-D4R: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. RED. DR-D4B: Door assembly, solid door, four tiers, BLACK, 28.40 lbs. DR-D4BR: Door assembly, solid door, four tiers, RED, 28.40 lbs. SBB-D4: Backbox assembly,four tiers, BLACK,40 lbs. SBB-D4R: Backbox assembly,four tiers, RED,40 lbs. TR-D4:Accessory semi-flush-mount trim ring,four tiers(open- ing 24.062"[61.118 cm]W x 45.812"[116.363 cm]H),BLACK, 3.80 lbs. NOTE:Black trim rings are used with red or black cabinets. BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox,3.10 lbs. ACCESSORIES ADP-4113:Annunciator dress panel. CAB-BM: For use with "B" sized cabinets in Marine applica- tions. See DN-60688 for more information. CB-1: Chassis bridge. Provides a bridge between CHS Series chassis. DP-1 B: Blank dress panel,covers one CAB-4 tier, BLACK. SEISKIT CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030, NFS2-640, and NFS- 320SYS. Includes battery bracket for two 26 AH batteries. VP-213: Ventilator panel. WC-2: Wire channel. Provides a pair of wire trays to neatly route wiring between CHS chassis. Agency Listings and Approvals These listings and approvals below apply to the CAB-4 Series Cabinets. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process.Consult factory for latest listing status. Page 2 of 6—DN-6857:C2•6/19/2012 Cabinet Dimensions and Features (13.097) (6.197) 5.156" 2.44 0 CAB4keyhole.wmf —------i---- 5.93" 0 Knockouts on (15.062) 1.125 top of cabinets. ------- (2.858 cm) ^ n 0.250 : :(0.635 cm) 7.12" 0 Height of ----01� ------TA (18.084) mounting bolt 0.5001 after installation (1.27 cm) KNOCKOUTS: --------- Inner. /C 5.93" ------- 0.875"(2.223) (15.062) 1.25" Keyhole Outer. LL.125 d i ril e n s I v I s "(2.858) (1.27 cm) T Top knockout: Inner 1'375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5-5/32" 2-1/16" i. 24-1/8"(61.28) (10.16): (13.1) j (5.24) 4" P: 16"(40.64) "A" SIZE (4.13) 8-5/8" 20-1/8" CABINET 11-9/32" (21.91) (51.12) 5/16"dia. 5/16"dia. (28.66) ---a-------- (0.79) (0.79) 2 0" t 0 G (5080) 19-1/2"(49.53) (CM) Iii L cab-a4-2003.wmf : 2-9/16" 2-1/4"(5.72) (6.51) Lower knockout: Inner 0.675 RZ Outer 1.125 (2.22 DN-6857:C2-6/19/2012—Page 3 of 6 Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5.218" 2.063" (10.16) :(13.254 (5.24) 24.125"(61.28) 16"(40.64) 14.025" 1.625" 4.62'.(11.74) "AA" SIZE (4.13) 13.9" I--- (35.624) 0.313"dia. (3 1 --- --- -4 CABINET (0.79) (27.94) 5.3 -------------- (CM) cab-b4-2003.wmf 19.5"(49.53) 2.56"; (6.51 2.25"(5.72�1)� Lower knockout: Inner 0.875 (2.22) Outer 1.125 (2.86) Top knockout: Inner 1'375"(3.49) Outer 1.750"(4.45) 14 24"(60.96) 5-5/32" 2-1/16" (10 24-1/8"(61.28) 4_416): 16"(40.64) (4.13) (13.1) (5.24) --- -------------;" ------ ---- -10------- "B" SIZE 8-5/8" CABINET 19-25/32" (21.91) (50.24) ---a-------f---- 8-5/8" 28-5/8" 28-1/2" (21.91) 5/16"die. 5/16"dia.(72.71) (0.79) (0.79) (72.3 Of --------------- 19-1/2"(49.53) 2-1/4" (5.72) (CM) cab-b4-2003...f 2-9/16;" 2-1/4"(5.72) (65.088) Two lower knockouts Inner 0.875"(2.88) Outer 1.125"(2.22) Top knockout: Inner 1.3753.49) Outer 1.750"(4.45) 24"(60.96) (10 1-5/8" 5-5/32" 2-1/16" 24-1/8"(61.28) 6): (13.1) (5.24) 16"(40.64) (4.13) ------------I __--- ------ ---- "C" SIZE 8-5/81, CABINET (21.91) 28-3/32" (21.91) (71.36) 0 8-5/8" 37-1/4" 37-1/8" (21.91) (94.62) 5/16"dia. 5/16"dia. (9 3) ---&------- (0.79) (0.79) 0 ----------------- 19-1/2"(49.53) 2-1/4" (5.72) 2-1/4" (5.72) (CM) LL cab-c4-2003.wmf 2-9/16" (6.51) Three lower knockouts Inner 0.875"(2.86) Outer 1.125"(2.22) Page 4 of 6 DN-6857:C2-6/19/2012 Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5-5/32" 2-1/16" 24-1/8"(61.28) 16"(40.64) (4.13)" (13.1) (5.24) "D" SIZE 8-5/8" CABINET (21.91) 8-5/8" (21.91) 37-1/32" (94.06) 8-5/8" (21.91) 45-7/8" 45-3/4" (11 .52) (116.21) (21.91) 5/16"dia. 5/16"cla. (0.79) (0.79) Of 19-1/2"(49.53) --2-1/4" (5.72) 2-1/4" (5.72) (CM) cab-d4-2003.wmf 2-9/16 (6.51) :our lower knockouts Inner 0.875"(2.86) Outer 1.125"(2.22) 2 9/16� �6 51 The BP2-4 Battery Plate covers the Main Power Supply "D"sized cabinet and the batteries in the cabinet. with solid door. Only one BP2-4 is required per cabinet Solid door option available unless an AA cabinet is used(no battery compartment). on all sizes in black or red. DN-6857:C2-6/19/2012—Page 5 of 6 ONYX® and NOTIFIERO are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I O 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-6857:C2.6/19/2012 DN-6881:A1 •A-35 LCM-320 and LEM-320 NOT 1 F 1 E R° Loop Control and Expander Modules by Honeywell Intelligent Fire Alarm Control Panels General The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX@ Series of Fire Alarm Control Panels (FACPs) with Signaling Line Circuits m .; (SLCs).The ONYX®Series NFS-640/NFS2-640 supports one LEM-320;the NFS-3030/NFS2-3030 supports up to five LCM 320s and five LEM-320s. The LEM-320 module is used to expand the NFS-640/NFS2-640 to a second loop, and to expand each LCM-320 used on the NFS-3030/NFS2-3030— each NFS-3030/NFS2-3030 LCM-320 supports an expansion LEM-320. w Features o • Up to 12,500 feet(3,810 m)on a Class B(Style 4)SLC loop (twisted-unshielded). • Built-in degraded mode increases survivability. • Very simple installation—plug-in style. ° • Permits multiple loops in small enclosure. Specifications Loop Control Loop Expander Voltage:24 VDC nominal,27.6 VDC maximum. Module Module Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2)twisted-pair wire is 12,500 feet Product Line Information (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2)to 18 AWG(0.78 mm2): LCM-320 Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- -Distance with 12 AWG: 12,500 ft(3,810 m). 320s and five LEM-320s. —Distance with 14 AWG:8,000 ft(2,438 m). LEM-320: Loop Expander Module. Expands each LCM used —Distance with 16 AWG:4,875 ft(1,486 m). on the NFS-3030/NFS2-3030;expands NFS-640/NFS2-640 to —Distance with 18 AWG:3,225 ft(983 m). two loops. —50 ohms maximum per length of Style 6&7 loops. —50 ohms maximum per branch for Style 4 loop. Agency Listings and Approvals Maximum current:for LCM-320: 130 mA;for LEM-320: 100 The listings and approvals below apply to the basic LCM-320 mA;for single SLC loop:400 mA maximum. and LEM-320. In some cases, certain modules may not be NOTE:Maximum short circuit—loop will shut down until short-cir- listed by certain approval agencies, or listing may be in pro- cuit condition is corrected. cess.Consult factory for latest listing status. Maximum resistance: 50 ohms (supervised and power- • UL: S635 limited). • ULC: S635/CS118 Temperature and humidity ranges: This system meets . FM Approved NFPA requirements for operation at 0—49°C/32—120°F and • CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 at a relative humidity 93% 2% RH (noncondensing) at 32°C with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 2°C (90°F 3°F). However, the useful life of the system's 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- standby batteries and the electronic components may be 0028:244(LEM-320 with NFS2-640). adversely affected by extreme temperature ranges and humid- . FDNY:COA#6025(LEM-320 with NFS2-640) ity. Therefore, it is recommended that this system and its FDNY:COA#6026(LCM-320/LEM-320 with NFS2-3030) peripherals be installed in an environment with a normal room temperature of 15—27°C/60—80° . City of Denver F • Hong Kong DN-6881:A1•06/05/2009—Page 1 of 2 FLASHSCAN® and NOTIFIERO are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6881:A1•06/05/2009 DN-60686:A1 U DA T 2 N OT I F I E R° Universal Digital Alarm Communicator Transmitter by Honeywell Annunciator Control System General The Universal Digital Alarm Communicator Transmitter(UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and t P on the NCA-2 Network Control Annunciator.When used in con- junction with the NCA-2 network control annunciator, the 9 UDACT-2 can report the status of all control panels on NOTI•FIRE•NETTM.The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network.The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. u - NOTE: The UDACT-2 can also be used with legacy panels. -am - Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The 4 UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. _ When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- I ing may be in the form of points or zones(refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- -- flow,supervisory,etc. UDACT-2 NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Adernco Contact ID format. See chart Open Collector relay driver for Total Communications Failure on page 2 for compatible receivers. or UDACT-2 trouble. Features • Real-time clock. • Extensive transient protection. • Programmable with VeriFire Tools version 6.60 or higher, . EIA-485 interface to host panel. allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Programming • Maximum of 14 point trouble messages transmitted per hour. The UDACT-2 programming is created and downloaded using • Dual phone lines with line voltage detect. VeriFire Tools. This enables the unit to be programmed prior to • Compact in size:6.75"x 4.25"(17.145 x 10.795 cm). installation, be easily modified, and saved either online or • USB port for upload/download programming. offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- • Manual Test Report function. work annunciator.The point report consists of the central station • Manual Transmission Clear function. point address,ACS point,ACS point function,panel label, panel • Mounts in a separate enclosure(ABS-8RB or UBS-1 B/R). point,type code, custom and extended label, alarm verification, • Communicates vital system status including: walktest participation,presignal,and PAS information.The zone -Independent zone fire alarm. report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label -Independent zone non-fire alarm. and panel label. This report may be sent to the Central Station -Independent zone trouble. for their records. VeriFire Tools also supports upgrading the -Independent zone supervisory. UDACT-2 operating firmware. -AC(mains) Power Loss(programmable). -Low Battery and Earth Fault. -System Off-Normal. -12 or 24 hour test signal. -Abnormal Test Signal per new UL requirements. -EIA-485 Communication Bus Failure. • Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. • Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. DN-60686:A1•4/2/12—Page 1 of 2 Communication Formats UL Listed Receivers • Ademco Contact ID The chart below shows UL listed receivers compatible with the • 4+2 Standard UDACT-2. A check in the protocol column indicates the receiver • SIA supports that protocol. NOTE: Ademco Contact ID must be used for independent zone reporting. 4+2 Ademco Type Mode Feature Standard Contact Ademco Contact ID format - only Use Type Mode to identify Receiver 1800/2300 ID SIA reports to Central Station as: Ademco 685(1) • Fire Alarm •Burglary • Supervisory •24 hour Non-Burglary Ademco MX8000(2) • Pull Station •High Temperature • Heat Detector •Low Temperature Silent Knight 9500(3) • Waterflow •Low Water Pressure Silent Knight 9800(4) • Duct Detector •Low Water Level • Flame Sensor •Pump Failure FBI CP220FB(5) • Smoke Zone Osborne Hoffman 2000E(6) Electrical Specifications Radionics 6600(7) Standby current:40 mA. SurGard MLR2(8) Current while communicating: 75 mA. Maximum current while communicating and with open collector SurGard System III(9) output activated: 100 mA. SurGard MLR-2000(10) Voltage: Regulated 24 volts. Range:21.2 to 28.2 volts. Agency Listings and Approvals (1)With 685-8 Line Card with Rev 4.4d software (2)With 12406OV206B and 124063 Line Card Rev B In some cases, certain modules may not be listed by certain (3)With version V2.4 Receiver& 126047 Line Card Rev G approval agencies, or listing may be in process. Consult factory for latest listing status. (4)With 124077V2.00 Receiver&126047 Line Card Rev M • UL/ULC Listed:S635 (5)With software V3.9 • FM Approved (6)With V.7301 Receiver S/W • CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (7)With 01.01.03 Receiver S/W&Line Card 01.01.03 (NFS2-3030) (8)With software V1.86 • FDNY:COA#6085,COA#6098 (9)With sotware V1.72 Ordering Information (10)With DSP4016 and V1.6 Line Card UDACT2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions,and mounting hardware. MCBL-7: DACT phone cord,7 ft(2.13 m)long(two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP.9.94" H x 4.63"W x 2.50" D(cm:25.248 H x 11.760 W x 6.350 D). UBS-1 B: Metal enclosure with solid door, Black. UBS-1 BR: Metal enclosure with solid door, Red. R-10E:SPDT Form-C relay.Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E:DPDT Two Form-C relays.Contacts rated for 10A @ 115 VAC.Connects to open collector relay driver. NOTI•FIRE•NETT^^is a trademark and Notifier®is a registered trademark of FBD-1: Ferrite bead kit. Use for remote mounting only. Honeywell International Inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. S 0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60686:A1•4/2/12 �J NOT 1 F 1 E R° by Honeywell DAA2 Series Digital Audio Amplifiers General The DAA2 Series amplifiers are multi-featured amplifiers with digital o :x c" -• ®,�•, ,. • • audio functionality. Each DAA2 is capable of accessing and process- ;a „°e°n' 3•p ing one of up to eight audio channels on the DVC audio loop,ampli- fying the signal, and distributing it via four Class B, two Class A ..,_.....::.,; _ �•• outputs, or four Class A outputs in DAA2 amplifiers with a DCADC • • ,A • • •�• Class A expander.A DAA2-50 or DAA2-75 series amplifier is capa- 3 • • • • • • • ble of mounting an optional BDA Digital amplifier,which can be used ®®••i!i •• j 3` to provide one-to-one amplifier backup, or to support two-channel •�• o ®®j operation, or increased output wattage to 10OW (100W option _ • • • • • • applies to DAA2-50 series only,other rules apply). -`-- The DAA2 has two wire digital audio ports to connect to wire DAL (digital audio loop)segments. Either or both ports may be converted to fiber using fiber option modules. Up to 106 seconds of backup digital message storage for use in Up to 32 devices,such as DAA2 amplifiers,can be connected to the the event of communication loss (from the VeriFire Tools mes- DAL on one DVC Digital Voice Command unit. DAA2 amplifiers may sage library,or created by the installer) be mixed with DAX and DAA series amplifiers on the same DAL. Battery charger disable provides battery sharing option for up to An optional Firefighter telephone riser on the DAA2 supports local four DAA2s and network FFT communications.A DAA2 also supports use of an Disconnect of deeply-discharged battery(low battery disconnect) RM-1 remote microphone. DAA2 amplifiers can store backup alarm and trouble messages,and Installation provide an adjustable background music input. The DAA2 arrives from the factory already installed on its chassis. The DAA2 mounts in one row of any EQ or CAB-4 Series cabinet: Features The CAB-4 row can be covered using a DP-1 B dress panel,ordered • Listed to UL Standard 864,9th edition separately. • 50 W total output power at 25 VRMS (all DAA2-5025 models) or One or two fiber option modules will plug directly onto a DAA2 for 70 VRMS(all DAA2-5 power models) simple installation. A BDA backup amplifier mounts directly onto a DAA2. • 75 W total output power at 25 VRMS(all DAA2-7525 models) Batteries for the DAA2 may be installed in any of the following con- Supports two Class A high-level audio outputs, or four Class A figurations: outputs in DAA2 amplifiers with a DCADC Class A expander, or four Class B outputs In a CHS-BH1 optional battery chassis. The CHS-BH1 battery • Optional BDA amplifiers support alternative configurations chassis will hold two 12.0 AH batteries, and mounts on the left side of the DAA2 chassis, so that the DAA2 and batteries are • Backup amplifier - supports one-to-one backup (all DAA2 mod- contained in a single cabinet tier. (This option is not available in els) DAA2 amplifiers with a DCADC Class A expander). • Primary amplifier - supports two-channel operation (all DAA2 In the battery row(bottom)of the CAB-4 Series cabinet, or in the models) bottom row of an EQ Series cabinet. • Primary amplifier-increase power up to 100W,one-or two-chan- In a cabinet adjacent to the cabinet that holds the DAA2, with nel operation. (DAA2-50 series only,configuration rules apply.) connections in conduit. External battery charging is supported. • Supports one-to-many amplifier backup applications using the same model DAA2 • Firefighter telephone riser supports 7 active firefighter tele- phones.System Release 3.0 and higher supports optional config- urations: direct connection for up to 7 firefighter telephones, or connection to multiple FTM-1 modules • Remote microphone paging option with RM-1 • Audio output activation via network control-by-event equations resident within the DVC • Two wire digital audio ports that can be converted to fiber using fiber option modules. Support Style 4 or 7 configurations • Auxiliary input for 1 VRMS, to be used for background music input, an interface with a telephone paging source, or other com- patible audio sources.Audio levels can be adjusted by end user. Optional supervision through programming • Isolated alarm bus input, to be used for backup activation of alarm messages when normal digital communication is lost • Programmable through VeriFire®Tools DN-60556:D•12/10/2020—Page 1 of 3 Standards and Codes Product Line Information The DAA2 Series Digital Audio Amplifiers comply with the following 50 WATT DAA2 AMPLIFIERS standards: Shipped mounted to the chassis. • NFPA 72 2007 National Fire Alarm Code DAA2-5025: 120 VAC Digital Audio Amplifier(50 W,25 VRMS) • Underwriter Laboratories Standard UL 864 DAA2-5025-CLA: 120 VAC Digital Audio Amplifier(50 W,25 VRMS) • Underwriter Laboratories of Canada (ULC) ULC-S527-11 Stan- with DCADC Class A expander dard of Control Units for Fire Alarm Systems DAA2-5070: 120 VAC Digital Audio Amplifier(50 W,70 VRMS) • Part 15 Class A conducted and radiated emissions as required by the FCC DAA2-5070-CLA: 120 VAC Digital Audio Amplifier(50 W,70 VRMS) • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000(Seismic). with DCADC Class A expander • CBC 2007(Seismic) DAA2-5025E: 220-240 VAC Digital Audio Amplifier (50 W, 25 VRMS) Listings and Approvals DAA2-5025E-CLA: 220-240 VAC Digital Audio Amplifier (50 W, 25 These listings and approvals apply to the basic DAA2 Series Digital VRMS)with DCADC Class A expander Audio Amplifiers. In some cases, certain modules may not be listed DAA2-5070E: 220-240 VAC Digital Audio Amplifier (50 W, 70 by certain agencies,or listing may be in process.Contact NOTIFIER VRMS) for latest listing status. DAA2-5070E-CLA: 220-240 VAC Digital Audio Amplifier (50 W, 70 • UL Listed:S635 VRMS)with DCADC Class A expander • ULC Listed:S635 75 WATT DAA2 AMPLIFIERS • CSFM: 7165-0028:0243 (NFS2-640/NFS-320), 7165-0028:0224 Shipped mounted to the chassis. (NFS2-3030) DAA2-7525: 120 VAC Digital Audio Amplifier(75 W,25 VRMS) • Fire Dept. of New York: COA#6287A (NFS2-640/NFS-320), COA#6306A(NFS2-3030) DAA2-7525-CLA: 120 VAC Digital Audio Amplifier(75 W,25 VRMS) • FM approved with DCADC Class A expander DAA2-7525E: 220-240 VAC Digital Audio Amplifier (75 W, 25 VRMS) DAA2-7525E-CLA: 220-240 VAC Digital Audio Amplifier (75 W, 25 VRMS)with DCADC Class A expander BDA BACKUP DIGITAL AMPLIFIERS BDA-25V: Backup Digital Amplifier (25 VRMS), switch settings for 75,50,and 35 W operation. Provides a second audio channel when programmed as a primary amplifier. BDA-70V: Backup Digital Amplifier (70 VRMS), switch settings for 50 and 35 W operation. Provides a second audio channel when pro- grammed as a primary amplifier. FIBER OPTION MODULES IDS-FM: Fiber option module for multi-mode fiber. Converts a wire DAP(digital audio port)to a multi-mode fiber port. DS-SFM: Fiber option module for single-mode fiber.Converts a wire DAP(digital audio port)to a single-mode fiber port. DS-RFM: Fiber option module for multi-mode fiber. Used exclusively for compatibility with multi-mode fiber DVC or DAA. ACCESSORIES CHS-BH1: Battery chassis. Holds two 12.0 AH batteries. Mounts on the left side of the DAA2 chassis. DP-1113: Dress panel: covers one tier of CAB-4 Series cabinet.ACT- 25, ACT-70: Audio-coupling transformers. Used with AA-30 or DAA2-series amplifiers to drive thousands of amplifiers in large sys- tem applications. SEISKIT-DAA: Seismic kit for DAA, DAA2, and DAX series amplifi- ers. Required when using CHS-BH1 chassis. Includes battery bracket for two 12AH Power Sonic batteries. See document 53851. Page 2 of 3—DN-60556:D•12/10/2020 Specifications CPS-24 POWER SUPPLY BOARD DAA2 BOARDS AC Power(T131): Digital Audio Ports, wire media,A and B (TB2, TB3): Maximum • Models using 120 VAC,60 Hz input: distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18AWG, TP) FPL cable: 18 AWG (0.821 mm2) twisted-pair, —DAA2-5025/DAA2-5025-CLA-4.68A max. unshielded, power-limited. For approved cable types, see wiring —DAA2-5070/DAA2-5070-CLA-4.69A max. documentation, P/N 52916ADD: C Approved Wire Cables for Digital —DAA2-7525/DAA2-7525-CLA-4.68A max. Audio Loops. • "E"version models using 220-240 VAC 60 Hz input: Digital Audio Ports, fiber media, fiber option modules: Digital audio loop connectors support single-and multi-mode fiber with the —DAA2-5025E/DAA2-5025E-CLA-2.68A max. use of fiber option modules. Refer to the Fiber Option Module data- -DAA2-5070E/DAA2-5070E-CLA-2.68A max. sheet for fiber specifications. —DAA2-7525E/DAA2-7525E-CLA-2.68A max. Alarm Bus: Power-limited, supervised by source. Recommended Recommended Wiring: 12 to 14 AWG(1.6 mm O.D.)with 600 VAC wiring: 14-18 AWG twisted-pair. Requires 16VDC minimum @ 20mA insulation. across the terminals to activate. Nominal 24VDC. Shipping Weight: 13 lb(5.9 kg). Remote Microphone Interface: RMI power: +24VDC, power-lim- ited @ 100mA. Supervised. Recommended wiring: 14-18 AWG Secondary Power 5V and 24V AUX Outputs(TB2): twisted-pair, Max. 14 AWG. Nominal AC signal strength 2.5VRMS, 24 V AUX: Power-limited, 24V @ 0.5A, utilizes wire sizes 12-18 3VRMS Max. Maximum distance between remote microphone and AWG(3.31 mm2-2.08 mm2. DAA2: 100 ft(304.8 ni 5 V: Future Use. FFT Riser: Power-limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3.9k ohm 1/2 watt Battery Connections: Supplied cable connections to batteries. resistor (P/N R-3.9K). Max. wiring resistance (including individual Battery Charger: Current-limited sealed lead acid battery charger telephone zone to last handset) permitted is 50 ohms, 10,000 ft which charges two 12 volt batteries in series, up to 200 AH: (3048 m)max.wiring distance at 14 AWG to last handset. Auxiliary Input: Signal strength from low-level analog audio input Charge Charge Charge (such as background music or telephone paging): 1Vp-p max. 7 AH to 26 AH to 50 AH to Optional supervision through programming. Recommended wiring: 26 AH <50 AH 200 AH 14-18 AWG,twisted-pair.Auxiliary input source must be within 25 ft. Batteries Batteries Batteries (7.6 m)of the DAA2, and within the same room. DAA2-5025 Speaker circuits: Power-limited outputs (exception: a DAA2-5070 DAA2-5025-CLA Yes Yes Yes speaker circuit used with any Canadian Room Isolator module is DAA2-5070 non-power limited. Speaker circuit 1 (TB10) cannot be used.). DAA2-5070-CLA Supervision determined by programming. DAA2-5025/70, Each cir- DAA2-7525 Yes Yes No cuit rated up to 50 watts`. DAA2-7525, each circuit rated up to 75 DAA2-7525-CLA watts. Recommended wiring: 12-18 AWG twisted-pair (shielded DAA2-5025/ recommended). Class B or Class A: Class B requires 20k end-of- DAA2-5025-CLA line resistors(included, P/N ELR-20K). Class A requires 10k end-of- or DAA-5070/ line resistors(included, P/N R-10K)on the return. No No No DAA-5070-CLA w/ *Total wattage may vary per configuration. BDA in Group 2 of UeriFire°Tools Backup: High-level audio input: 25VRMS (DAA2-5025 and DAA2- 7525). 70 VRMS (DAA2-5070). Recommended wiring: 14-18 AWG. Not supervised when inactive. Supervised by backup source when active. Must be in same room or enclosure. I® ENGIMEERING R MANUFACTURING 0UAEITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. N OTI F I E R iNOTIFIER®and VeriFireo Tools are registered trademarks of Honeywell International Inc. 12 Clintonville Road ©2020 by Honeywell International Inc.All rights reserved.Unauthorized Northford,CT 06472 use of this document is strictly prohibited. NOT 1 F 1 E R 203.484.7161 www.notifier.com Country of Origin:USA by Honeywell DN-60229:D EQ Cabinet NOTI FI E R° ONYX@ Series Equipment Backboxes 0 with Ventilated Locking Doors by Honeywell Peripheral Devices General e EQ Series cabinets provide an effective solution for applica- tions that require distributed components such as power sup- plies, amplifiers, and multiple 1/0 modules. The EQ Series provides superior ventilation for devices such as amplifiers and field power supplies, ample room for wire or fiber-optic media between each row, and a space efficient package that allows for the consolidation of multiple system components in a single enclosure. Equipment cabinets use a perforated blank door for enhanced ventilation, and do not support the mounting of backbox mounted dress plates.Therefore these cabinets are not appro- priate for equipment that would be normally accessed by a system operator such as control equipment, annunciators, or remote microphones. EQ cabinets share the same external dimensions as the famil- iar CAB-4 Series cabinets. EQ Series cabinets differ in that they do not include a separate battery row. See illustrations below for examples of EQ cabinet row spacing. Specifications • Equipment cabinets are fabricated from 16-gauge steel. d The cabinet assembly consists of two basic parts: a back- w box and a locking door. Cabinets are available in black and red. • The key-locked door is provided with a pin-type hinge, two • XP6-MA Modules keys and the necessary hardware to mount the door to the • XP6-R Modules backbox. • XP10-MA Modules • The backbox has been engineered to provide ease-of-entry for the installer. Knockouts are positioned at numerous Agency Listings and Approvals points to aid the installer in bringing a conduit into the These listings and approvals below apply to the EQ cabinet. In enclosure with a minimum of hardship. some cases,certain modules or applications may not be listed • Right- or left-hand hinges, selectable in the field. Door by certain approval agencies, or listing may be process. Con- opens 180°. sult factory for latest listing status. • Cabinets are arranged in 3 standard sizes, B (two tiers) . UL Listed: S635. through D(four tiers). See Ordering Information. • ULC Listed: S635. • Trim ring options are available for semi-flush mounting. • CSFM: 7165-0028:0243 (NFS2-640), 7165-0028:0224 Equipment Compatible for Use in (NFS2-3030). . FDNY: COA#6121 (NFS2-640), COA#6114 (NFS2-3030), EQ Series Cabinets COA#6073. • DAA2 Series Amplifiers • DAX Series Amplifiers Ordering Information • DS-DB Digital Series Distribution Board A complete cabinet assembly consists of a door, a backbox, • DS-AMP Digital Series Amplifier and an optional semi-flush trim ring. For each cabinet • DAA-50 Series Amplifiers required,order one"EQDR"door and one"EQBB" backbox. • DAA-75 Series Amplifiers The optional trim ring is an attractive "picture-frame" style • AA-30(E)Audio Amplifiers black metal ring. • AA-100(E)Audio Amplifiers `B"SIZE CABINET(TWO TIERS) • AA-120(E)Audio Amplifiers EQDR-B4: Door assembly, vented door, two tiers, black. (For • ACPS-610(E) Power Supply red,order EQDR-B4R.) • AMPS-24(E) Power Supply EQBB_B4: Backbox assembly, two tiers, black. (For red, order • HPFF8CM(E) Power Supply 4 •) • HPFFI2CM(E) Power Supply TR-B4: Semi-flush-mount trim ring,two tiers. • XP6-C Modules DN-60229:D•03/19/2013—Page 1 of 4 "C"SIZE CABINET(THREE TIERS) "D"SIZE CABINET(FOUR TIERS) EQDR-C4: Door assembly,vented door,three tiers, black.(For EQDR-D4: Door assembly, vented door, four tiers, black. (For red,order EQDR-C4R.) red,order EQDR-D4R.) EQBB-C4: Backbox assembly, three tiers, black. (For red, EQBB-D4: Backbox assembly, four tiers, black. (For red, order order EQBB-C4R.) EQBB-D4R.) TR-C4: Semi-flush-mount trim ring,three tiers. TR-D4: Semi-flush-mount trim ring,four tiers. CABINET DRAWINGS AND FEATURES Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5-5/32" 2-1/16" (10.16); 1-5/8" 24-1/8"(61.28) j ) (1 .1 (5.24) 4" 16 (40.64) (4.13 {---- - -- ------------- -- ................................................I 11-1/2" ................................................I (29.21) ................................................I ................................................I ................................................. ................................................. 1 (2.54) 11" ................................................ 37-1/32" (27.94) I ................................................. ................................................I � 11" ................................................I (27.94) ................................................45-7/8" I ................................................. ................................................. (116.52) ::::::::::::::::::::::::::::::::::::::::::::::::: (116.21) ................................................. 5/16"dia. 5/16"dia. ................................................ (0.79) (0.79) ................................................. ................................................. �► ................................................. ................................................. ................................................. O {3 19-1/2"(49.53) 2-1/4" (5.72) (5.72)11 ((CM) L: __. egcab-d.wmf ;HI : 2-5/8" 1-7/8" EQDR-D4 EQBB-D4 Box (4.699) Four lower knockouts Inner 0.875"(2.22) Outer 1.125"(2.86) Page 2 of 4—DN-60229:D•03/19/2013 Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5 5/32" 2-1/16" 24-1/8"(61.28) 1 8 (13.1) (5.2324) 4"��16"(40.64) � (4.13) �� ---- - --------------- -- ................................................. ................................................ ................................................I 11-1/2" ................................................. (29.21) ................................................. ::::::::::::::::::::::::::::::::::::::::::::::::: ................................................. 28-3/32" (71.36) � �i" ( ) (2.54) 11" ................................................. (27.94) ................................................. ................................................. 37-1/4" (94.62) 37(943) �� 5/16"dia. 5/16"dia. m ................................................. (0.79) (0.79) ................................................. ------------ ................................................. ................................................. O {3 j�19-1/2"(49.53) 2-1/4" (5.72) 2-1/4" (5.72) (CM) iririririririririiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii eqcab-cmmf 1-7/8" rH' 2-5/8" EQDR-C4 EQBB-C4 Box (4.699) !'— (6.604) Three lower knockouts Inner0.875"(2.22) Outer 1.125"(2.86) Top knockout: Inner 1.375"(3.49) Outer 1.750"(4.45) 24"(60.96) 5 5/32" 2 1/16" (10.16); 1-5/8" j� 24-1/8"(61.28) 16" 4 (13.1) (5.2324) 4 ( 0.64) (4.13) ................................................: 11-1/2" (29.21) 19-3/4" ................................................I (50.24) ................................................. 28-5/8" 28-1/2" -�d� t-2. 72.71 5/16"dia. 5/16"dia. 72.39 -- -- _3�1* (5.08) (72.71) (0.79) (0.79) ( ) ................................................. ................................................. ................................................I .l �. ................................................. ................................................. O {3- 19-1/2"(49.53) 2-1/4" (5.72) (CM) 60229cab2mW ;H: 2-1/4"(5.72) y►? 1 7/8" 2 5/8" (4.699) ;~�(6.604) EQDR-B4 EQBB-B4 Box Two lower knockouts Inner 0.875"(2.22) Outer 1.125"(2.86) DN-60229:D•03/19/2013—Page 3 of 4 Top knockout: (13,097) (6.197) Inner 1.375"(3.49) Outer 1.750"(4.45) 5.156" 2.44 1.125 5-5/32" 2-1/16" (2.858 cm) :4- :0.250 j (13.1) 0 (5.24) (0.635 cm) ------ 5.93" 0.500, (15.062) (1.27 cm) -------I----11 1/2" ------------+ (29.21) 7.12" L­ (18.084) t.�50 , -0----------i-f---�F­f (1.27 cm) (��'0-0, (5.08)1 c (2.54) KNOCKOUTS: T (27.94) Inner. 5.93" Mounting Hole _f (2.858)0.875"(2.223) (15.062) Outer: 00 1 V 1.125" 81 --- 4 '/4 (27.94) 5-3 " (116.21) _Q---------------------I Top View of Backbox C 1-17/20'—' '—: 2_9/16 (4.699) (6.51) Four lower knockouts Inner 0.875"(2.22) Outer 1.125"(2.86) Side View of Backbox (EQBB-D4) Notifier@ is a registered trademark of Honeywell International Inc. @2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. IS09001We try to keep our product information up-to-date and accurate. 111!21-7772=71171 We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60229:D•03/19/2013 DN-6040:A2•E-191 CHGA20 NOTI FI E R° Battery Charger by Honeywell Power Supplies General The CHG-120 is a state-of-the-art battery charging system designed for use with NOTIFIER Fire Alarm Control Panels (FACPs). It is designed to charge lead-acid batteries between 25 and 120 ampere-hours(AH). Features ®®®� • Charges sealed lead-acid batteries. • Automatic float-type battery charger. Pi .,• • Rated for batteries of 25 to 120 ampere-hours. • Obtains full float voltage within 48 hours. • For use on any 24-volt FACP which can handle the speci- fied batteries and can disable the local charger. • AC Fail delay (central station applications) per latest NFPA requirements. • Form-C Trouble contact. 3 • Dual outputs,for easy load distribution. • Diagnostic LEDs: —Primary AC On —Charger Trouble. —Ground Fault. —Hi Charge. Charging time(to charge two fully discharged batteries): —Lo Charge. — 25 AH=9 hours. —Battery Voltage Level (3 LEDs). —55 AH/60 AH=20 hours. —Low Battery. —120 AH=38 hours. • Black or red NFS-LBB(R)battery cabinet(optional). • Field-selectable input voltage, 120 VAC or 230 VAC. Installation • Charges: The CHG-120 has a variety of mounting options. It can be —26 AH batteries within 9 hours. mounted in either a CAB-4 Series backbox or remotely in the —55/60 AH batteries within 20 hours. NFS-LBB Battery Backbox. Install the CHG-120 within 20 feet —120 AH batteries within 38 hours. (6.096 m)of the main FACP. NOTE:Values per NOTIFIER testing. When mounting in a CAB-4 Series backbox: • The CHG-120 can be mounted in the main power supply Construction and Operation position, on the lower left of the CAB-4 Series backbox. The CHG-120 consists of a PC board and mounting chassis. • Using self-tapping screws,the CHG-120 can be mounted in Charging current is provided automatically when the battery the lower right position (normally, where the batteries are voltage falls below the charger's output voltage. mounted)of the CAB-4 Series backbox. When mounting remotely in the NFS-LBB: Applications • The CHG-120 mounts in the left position of the backbox. Use the CHG-120 when batteries required for standby are NOTE: Only one 55 AH battery or two 26 AH batteries will mount rated between 25 to 120 AH. with the charger board in the NFS-LBB. NFS-LBB Battery Box Battery Configurations: The battery CHGA 20 Specifications ac ox can mount configurations of batteries as follows: Primary AC(T131): • Without CHG-120 mounted internally: —115 VAC,60 Hz,2 A. —Up to two 26 AH batteries. —230 VAC,50 Hz, 1 A. —Up to two 55/60 AH batteries. Form-C relay(TB3): 5 A at 30 VDC. —One 100 AH battery. Float charge voltage:27.6 VDC. • With CHG-120 mounted internally: Maximum charging current:4.5 A. —Up to two 26 AH batteries. Fuses F1-F3: 15 A. —One 55/60 AH battery. —One 100 AH battery. Battery sizes:26 AH to 120 AH. DN-6040:A2•10/18/2012—Page 1 of 2 NOTE: When 100 AH batteries are required, a NFS-LBB is Compliance with Codes and Standards required to mount each 100 AH battery.The CHG-120 can mount in either the CAB-4 Series backbox or in a third NFS-LBB in this The CHG-120 complies with the following standards: configuration. • NFPA 72 National Fire Alarm Code. Product Line Information • UL 864 Standard for Control Units for Fire Alarm Systems. • UL 1481 Power Supplies for Fire Alarm Systems. CHG-120: Battery charger circuit board and mounting chassis. . CAN/ULC-S527-M87. Includes mounting hardware and installation instructions. BAT 12260:26 AH, 12-volt, sealed lead-acid battery. Order as Agency Listings and Approvals bulk pack BAT-12260-BP, contains two. See data sheet DN- 6933. The listings and approvals below apply to the basic CHG-120. In some cases, certain modules may not be listed by certain BAT 12550:55 AH, 12-volt,sealed lead-acid battery. See data approval agencies, or listing may be in process. Consult fac- sheet DN-6933. tory for latest listing status. BAT 121000: 100 AH, 12-volt, sealed lead-acid battery. See . UL: S674. data sheet DN-6933. • ULC: S635. NFS-LBB: Battery Backbox—holds up to two BAT-12550 55 . FM:Approved. AH batteries or one BAT-121000 100 AH battery. Dimensions: Box: 24.0" (61.0 cm)wide x 14.0" (35.6 cm) high x 7.75" (19.7 • Ill 7315-0028:0189. cm) deep. Door: 24.125" (61.3 cm) wide x 14.25" (36.2 cm) • MEA: 195-97-E, 345-02-E. high x(door adds 0.063" [approx. 0.16 cm]to depth), black. • FDNY:#6114. NFS-LBBR: Same as NFS-LBB above but painted red. CHG-120 Features Voltage Selection Switch for 115 VAC or 230 VAC Nine LED Status operation Indicators Open Collector Trouble ® Daisy Chain Connections ®®® External Trouble Input F= a ® NFS-LBB Battery Backbox 3 Form-C Relay to other devices Two output circuits to load (power supply, aux.power supply, amplifier,etc.) 25 AH-120 AH Battery 15A replaceable fuses Connections provide short circuit and Optional Ammeter overload protection Connection NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6040:A2•10/18/2012 DN-6940:C•D-115 L D 160 NOTI FI E R° Liquid Crystal Display by Honeywell Annunciator Control Systems General The LCD-160 is a 640-character Liquid Crystal Display (LCD) annunciator and remote control for the NOTIFIER NFS-3030/ NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030's 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and can display other panel information. LCD-160 Features • 640-character Liquid Crystal Display with backlit control. - - -W- - - -• •- • On-board input, output, and status indicators to support a„ diagnostics. A .! ' ■ • Software upgrades and foreign-languages character sets via serial port from a panel or other device using the Remote Data Port(RDP)interface. Upgrades do not require the replacement of any programmable devices. • Rubberized keypad. • Input for AKS-1 B key switch. • Fits in two ACS annunciator module locations. • Display and Control Center(DCC)participation/indication. Current draw: Standby current: 0.300 A with backlight on, 0.075 A with backlight off. Alarm current: 0.325 A with back- RDP Interface light on,all LEDs active. Any communication between the control panel and any RDP RDP BUS WIRING SPECIFICATIONS device,such as the LCD-160,occurs over an RDP interface. Wiring distance:4000 feet(1219.2 m)at 18 AWG(0.78 mm2) • RDP interface communication is supervised by the FACP between the panel and the last device on the RDP bus (sub- and the LCD-160. ject to system's power restrictions). • RDP bus can drive up to 32 RDP devices. The FACP must Wiring size: 18 to 12 AWG (0.78 to 3.1 mm2) twisted-pair be at one end of the bus;the last RDP device on the circuit cable,with characteristic impedance of 120 ohms 20%. must have an enabled end-of-line resistor. Wire resistance: Limit total wire resistance to 100 ohms on • Each LCD-160 on the bus requires a non-resettable 24 the RDP bus, and 10 ohms on the RDP device power circuit. VDC power connection. The power circuit is inherently Unloaded resistance between RDP connectors must be supervised and a loss of power registers as a communica- greater than 1 K ohm.A remote power supply is required if total tion failure at the control panel. power wiring resistance exceeds 10 ohms. • The LCD-160 can be powered by a regulated remote power NOTE: 1)DO NOT RUN CABLE adjacent to, or in the same con- supply listed for fire-protective signaling use. If the 24 VDC duit as: 120 VAC service;"noisy"electrical circuits that are power- power comes from a non-power-limited source, it must ing mechanical bells or horns;audio circuits above 25 Vrms;motor remain separate from the power-limited RDP bus. control circuits; SCR power circuits; or non-power-limited circuits. 2) Refer to LCD-160 Manual,document no.51850,if RDP devices Specifications are to be mounted in SEPARATE CABINETS or powered by REMOTE POWER SUPPLIES. Input supply voltage (TB2): Regulated, filtered 24 VDC via PHYSICAL SPECIFICATIONS non-resettable power supply interface listed for fire-protective signaling use. Sources can be: panels with integrated power Temperature/humidity range: This system meets NFPA supplies, main power supplies (AMPS-24, etc.), auxiliary requirements for operation at 0 —49°C/32 — 120°F and at a power supplies (APS2-6R, etc.); or a compatible accessories relative humidity 93% 2% RH (noncondensing) at 32°C output. If RDP devices are to be powered by separate power 2°C (90°F 3°F). However, the useful life of the system's supplies, a common reference connection must be estab- standby batteries and the electronic components may be lished. adversely affected by extreme temperature ranges and humid- Data communications port (TBi): Power-limited RDP inter- ity. Therefore, it is recommended that this system and its face. peripherals be installed in an environment with a normal room temperature of 15—27°C/60—80°F. Shipping weight:2.50 lb. (1.134 kg) DN-6940:C•3/10/17—Page 1 of 4 LCD-160 Interface and Indicators The liquid crystal display is 40 characters wide and 16 lines Trouble: Scroll/display a list of associated events. deep, and displays all programming screens and other infor- Other Event: Scroll between prealarm and disabled events. mation. The keypad is functional only when an entry is requested by the system. Enter or change fields and issue For complete information on key functions and effects on dif- commands on the display by using the two types of keys on ferent panels, refer to the LCO-160 Manual and panel manu- the keypad:fixed function and soft keys. als. Fixed function keys are the ten keys labeled on the front of Soft keys are the six keys to the right and left of the display. the LCD-160, operating at all times on all screens unless oth- Use them to select commands that appear on the display for erwise noted. With both an active command center and DCC each different screen. Refer to the screens in the LCD-160 enabled at the panel, Acknowledge, Signal Silence, System Manual for descriptions of the applicable soft keys. Reset, and Drill require permission before they can be pro- STATUS LED INDICATORS cessed. Acknowledge: Press to respond to any event or trouble sig- Power (green) illuminates when AC power is within normal operating limits. nal. If enabled,silences the LCD-160 piezo sounder.Sends an acknowledge message to the panel. Fire Alarm(red)illuminates when at least one fire alarm event Signal Silence: Press to send a system silence command to exists. It will flash if any of these events are unacknowledged. the panel, with the particular silencing action information Pre-Alarm(red)illuminates when at least one pre-alarm event stored at the FACP. Verification screen appears on networked exists. It will flash if any of these events are unacknowledged. displays. Security (blue) illuminates when at least one security event System Reset: Press to send a system reset command to the exists. It will flash if any of these events are unacknowledged. panel,with the particular reset action information stored at the Supervisory (yellow) illuminates when at least one supervi- FACR Verification screen appears on networked displays. sory event exists. It will flash if any of these events are unac- Drill: Press (hold for two seconds) to activate all silenceable knowledged. fire output circuits. System Trouble (yellow) illuminates when at least one trou- Lamp Test: Press to test the LED indicators and the piezo, or ble event exists. It will flash if any of these events are unac- display firmware version numbers. knowledged. Fire Alarm: Scroll/display a list of associated events. Other Event(yellow)(future release). Security: Scroll/display a list of associated events. Supervisory: Scroll/display a list of associated events. NUP cm J4 J3 �2 J1 1 LCD 92 BACKLIGHT LCD-1 60 KEY SWITCH 1 J2 2 LCD 19-+ 20 + POWER El r Un 0000[[0>> IN --In0000[[[0000000 L—� +24VDCOUT STATUS o omuouomuouomum�) COMMON IN TB2 LED11 0 = - COMMON OUT _ RDP MICRO FAIL o - - 2 TB1 RDP+ (,.uoiououoiouomuouoJ o o RDP+ LED14 0000000000000000{-- RDP- 0000000000000000 RECEIVE RDP- SW17 LED 12 REF E TRANSMIT REF LED 13 EARTH Page 2 of 4—DN-6940:C•3/10/17 Signals Silenced (yellow) illuminates if notification appli- work control to alternate network control centers.This protocol ances have been silenced. It flashes if some,but not all,of the allows for a "request for control' from another networked NACs have been silenced. panel, which will be accepted or rejected from the current Point Disabled (yellow) illuminates when at least one device DCC. A 15-second time-out allowance provides for an auto- has been disabled. It will flash until all disabled points have matic passing of control in the event there is no response from been acknowledged. the original DCC. If the NFS-3030/NFS2-3030 panel associ- ated with an LCD-160 has been programmed to participate in Controls Active (green) illuminates when the LCD-160 DCC, all remote displays with Local Control ON will automati- assumes control of the node as a primary display. cally participate. DIAGNOSTIC LED INDICATORS Status, LED11 (green), blinks when the LCD-160 is on. Visi- ble to the installer/troubleshooter only. These listings and approvals apply to the LCD-160. In some Receive, LED12 (green), blinks when data is received from cases, certain modules or applications may not be listed by the panel.Visible to the installer/troubleshooter only. certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. Transmit, LED13 (green), blinks when data is transmitted to UL: S635 the panel.Visible to the installer/troubleshooter only. Microfail, LED14 (yellow), illuminates if the microcontroller • ULC: -11. -04 8 fails.Visible to the installer/troubleshooter only. MEA:8 04 E (annunciator only) • FDNY:COA#6211 (with NFS2-3030) Event Handling and the • CSFM: 7120-0028:0227,7165-0028:0224 Display and Control Center • FM Approved UL and ULC require that when multiple command and control centers are installed, only one operator at any location can be in control at any given time for functions such as acknowledge, silence, and reset. This is called the Display and Control Cen- ter(DCC). DCC operation provides a mechanism to pass net- RDP Bus Wire Runs FACP LCD-160 Power 12 to 18 AWG (3.1 to 0.78 mle LCD-160 non-resetettable Two-wire RDP Bus 4000 feet(1219.2 m)max. power-limited and LJ supervised Sample Screen: Point Event Display ACKNOWLEDGED TROUBLE ELEVATOR LOBBY EAST WING FIFTH FLOOR Z239 SMOKE (PHOTO) 11:58:45A WED JUN 26, 2003 L03D002 EVENT COUNTS FIRE ALARMS:000 PREALARM:000 TROUBLE:001 SUPERVISORY:000 SECURITY:000 DISABLE:000 11:58:46A WED JUN 26, 2011 ' SIGNAL SILENCE ' ' MORE INFORMATION SYSTEM RESET ' FD �' PROGRAM MENU ' DN-6940:C•3/10/17—Page 3 of 4 Product Line Information LCD-160: 640-character Liquid Crystal Display annunciator. (11.43 cm)wide x 2" (5.08 cm) deep. NOTE: The ABS-1 B will LCD-160C for ULC applications. not support the installation of the AKS-1 B Annunciator Key SacWoxes Switch. CAB-4 Series cabinets: Surface- or semi-flush-mounted, in "C"suffix indicates ULC-Listed model. sizes to accommodate one to four rows of equipment plus bat- The following backboxes can be surface- or semi-flush- teries (up to two 26 AH batteries). Four sizes are available. mounted to provide an enclosure for remote mounting. Use Doors are ordered separately,and feature reversible hinges to with 1/2" (1.27 cm)conduit in the provided knockouts. mount doors on the left or right side. Doors also open a full ABS-211)(C) (black) and ABS-2DR (red): Surface or semi- 180°. Keylocks are included. For dimensions and further infor- flush enclosure for remote mounting. Mounts an LCD-160 mation,see datasheet DN 6857. directly to the enclosure's hinged dress plate.The ABS-2D and ACCESSORIES ABS-2DR do NOT support the installation of the AKS-1 B key- DP-DISP: Dress Panel Display for cabinet mounting of an switch. Not for use in Canadian applications. Optional trim ring LCD-160. LCD-160 mounts directly to the dress panel, which TR-ABS2D for semi-flush mounting. Dimensions, box: 12.0" hinge-mounts to the top tier of a CAB-4 Series backbox. (30.480 cm) H x 12.0" (30.480 cm) W x 3.797" (9.644 cm) D (NOTE: The black ABS-2D is slightly deeper). Dimensions, ADP-4B: Annunciator Dress Panel-413 (black) for cabinet door: 12.0" (30.480 cm) H x 12.0" (30.480 cm) W x 1.250" mounting of an LCD-160. LCD-160 mounts directly to the (3.175 cm) D. dress panel,which hinge-mounts to the tier of a CAB-4 Series ABS-41D(C) (black) and ABS-4DR (red): Surface- or semi- backbox. flush enclosure for remote mounting. Mounts an LCD-160 and TR-ABS2D: Optional trim ring for semi-flush mounting ABS- two annunciators directly to the enclosure's hinged dress 2D(R). plate.The ABS-4D and ABS-4DR do NOT support the installa- VP-213: Vented Dress Panel for use with the ADP-413 dress tion of the AKS-1 B key-switch. Dimensions, box: 11.97" panel installed in the top tier of a NOTIFIER cabinet. It covers (30.40 cm) H x 19.87" (50.47 cm) W x 3.5" (8.89 cm) D. the gap between the dress panel and top of the cabinet. Dimensions, door: 11.97" (30.40 cm) H x 19.87" (50.47 cm) W x 1.250" (3.175 cm) D. AKS-1 B:Annunciator Key Switch provides access security for the control switches on the LCD-160. Key-switch kit includes ABF-2113: Black flush enclosure for remote mounting. Mounts key, hardware, and an annunciator label. an LCD-160 directly to the enclosure's dress plate. Not for use in Canadian applications. Includes a painted black metal trim plate [11" (27.94 cm) high x 10.625" (26.99 cm) wide] and adhesive-backed annunciator label. 9.938" (25.24 cm) high x 9.188" (23.34 cm)wide x 3.75" (9.525 cm)deep. ABF-2DB(C): Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Does not support the installation of AKS-1 B. Box dimensions: 9.938" (25.24 cm) high x 9.188" (23.24 cm) wide x 3.75" (9.525 cm) deep.Door dimensions: 11" (29.94 cm) high x 10.375" (26.35 cm)wide x 0.75" (1.9 cm)deep. ABF-4113: Black flush enclosure for remote mounting of one LCD-160 and two annunciator modules directly to the enclo- sure's dress plate. Knockouts are provided for use with 1/2" (1.27 cm) conduit. Includes a painted black metal trim plate [11"(27.94 cm)high x 19.375"(49.21 cm)wide]and an annun- ciator label. 9.938" (25.24 cm)high x 17.75" (45.09 cm)wide x 2.5" (6.35 cm)deep. ABF-1 DB(C): Semi-flush box with alternative smoked-glass door, any keylock. ABF-1 B(C): Annunciator flush box, 9.938" (25.24 cm) high, 4.625" (11.75 cm)wide,and 2.5" (6.35 cm)deep. Order AKS- 1 B key switch and APJ-1 B phone jack if desired. Can also be mounted in ABF-26 or ABF-4B annunciator backboxes. ABS-11TB(C): Deep surface backbox(mounts one LCD2-80). ABS-1 B(C):The Annunciator Surface Box-1 B(black)provides for the remote mounting of one annunciator module in a sur- NOTIFIER®is a registered trademark of Honeywell International Inc. face-mount enclosure. Knockouts are provided for use with 1/ 02017 by Honeywell International Inc.All rights reserved.Unauthorized use 2" (1.27 cm) conduit. The annunciator mounts directly to the of this document is strictly prohibited. ABS-1 B/C without a dress plate. 8.5" (21.59 cm) high x 4.5" This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS country of origin:USA For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4-DN-6940:C•3/10/17 DN-6728:B RMA Series N OT I F I E R° Remote Microphone and Cabinets 0 RM-1 RM-1SA, CAB-RM, CAB-RMR by Honeywell Emergency Voice Evacuation GENERAL The RM-1 Series Remote Microphone provides a cost- effective microphone interface for paging to selected speaker zones. The Power and Trouble LEDs provide easy-to-under- EMERGENCY stand visual indications of its status. Various mounting MICROPHONE options are available. The microphone assembly can be mounted in a small, compact enclosure or located in a com prehensive paging command center. MICROPHONE The RM-1 Series remote microphone can be utilized with the DVC Digital Voice Command Center and DAA2 amplifiers, or to expand a legacy installation. :_. FEATURES • Automatic gain control circuit. • Supervised microphone. • Form-C trouble contacts. • Form-C contacts activated when microphone is in use. • Power On LED. • Trouble LED. • Pluggable terminal blocks. • Low-level audio(LLA) IN and THRU screws. CAB-3/CAB-4 SERIES INSTALLATION The RM-1 can mount to the back of an ADP-413 dress panel inside a CAB-3 or CAB-4 Series cabinet. It can be mounted in any of the four positions on the dress panel, with the fol- lowing exception: • Do NOT mount the RM-1 in front of a CHS-4L chassis. See page 2 for illustrations of mounted units. SPECIFICATIONS • MEA:327-94-E Vol.11l • CSFM: 7165-0028:0224(NFS-3030/NFS2-3030) Power requirements: 20 mA primary, non-fire alarm cur- . FM:Approved(RM-1, RM-1SA) rent;66 mA when microphone is activated;20 mA secondary, . FDNY: #6058(NFS2-3030) non-fire alarm current. Operating voltage: 17 to 26.4 volts. PRODUCT LINE INFORMATION RM-1: Remote microphone assembly for mounting on an ADP-46 dress panel. RM-1SA: Remote microphone assembly for mounting in a CAB-RM(R),for remote applications. CAB-RM: Stand-alone cabinet, black. CAB-RMR: Stand-alone cabinet, red. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the RM-1 Series Remote Microphone. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S635 • ULC: CS118/CS733 Vol. 12 DN-6728:B•7/28/2010—Page 1 of 2 RMA MOUNTING & GMEIEMGY ° CABINET DIMENSIONS MI0R0%ONE P"EN RIGHT: RM-1SA (right) and in CAB-RM or CAB-RMR. BELOW: RM-1 (left) and on "` 0 ADP-4B dress panel. EMERGE"P" O o� Rom 3 E E E E E o 6728rml.wmf tO 1.04" 6.08"(154.4) (26.4) 4.00"(101.6)� CAB-RM/CAB-RMR DIMENSIONS inches (mm) 1.00"(25.4) ---------------- 0 _T 3.655" (92.8) 4.29' 6.301" (109) (160) 8.301" ♦I (210.8) Ak DEPTH WITHOUT DOOR ----------- — ' HEIGHT/WIDTH WITHOUT DOOR NOTIFIERO is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6728:6.7/28/2010 DN-60429:C1 DNR(A)/DNRW InnovairFlex NOT 1 F 1 E R° Intelligent Non-Relay Photoelectric Duct Smoke Detector by Honeywell Intelligent Devices General The Notifier InnovairFlex®DNR(A) intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute(0.5 to 20.32 m/s), temperatures of-4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) cates a trouble signal for a removed or improperly installed Width,2.5 in (6.6 cm) Depth. sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- Size: (Square)7.75 in (19.7 cm) Length; 9 in(22.9 cm)Width; ing and mounting of a relay module. 2.5 in(6.35 cm) Depth. The Notifier InnovairFlex duct smoke detector can be custom- Weight: 1.6 lb(0.73 kg). ized to meet local codes and specifications without additional Operating Temperature Range: -4°F to 158°F (-20°C to wiring.The new InnovairFlex product line is compatible with all 70°C). previous Innovair models, including remote test accessories. Storage Temperature Range: -22°F to 158°F (-30°C to Features 70°C). Operating Humidity Range: 0% to 95% relative humidity • Photoelectric, integrated low-flow technology. (non-condensing). • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). 20.32 m/s). • Versatile mounting options: square or rectangular configu- Accessories ration. • Broad ranges for operating temperature (-4°F to 158°F, - Notifier provides system flexibility with a variety of accessories, 20°C to 70°C)and humidity(0%to 95%non-condensing). including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke • Patented sampling tube installs from front or back of the detectors, all duct smoke detectors accessories are UL listed. detector with no tools required. Cover tamper signal. DNR(W)s with a date code of 0013 or higher do not require • external 24VDC for remote test applications when used with a • Increased wiring space with a newly added 3/4" conduit remote-test-capable detector. knockout. • Available space within housing to accommodate mounting ACCESSORY CURRENT LOADS AT 24 VDC of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). RA10OZ OmA 12 mA Max • Clear cover for convenient visual inspection. RTS151/ • Remote testing capability. RTS151KEY OmA 12mA Max • Requires com line power only. • Accommodates the installation of an addressable relay Agency Listings and Approvals module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S911, S3705. • ULC: S635. DN-60429:C1•4/19/2012—Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE:"A suffix indicates ULC listed model. Pe Pcec ): Intelligent non-relay photoelectric low flow smoke or housing. Requires photoelectric smoke detector(sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately). FSP-851 R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft(0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier0 and FlashScanO are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60429:C1 •4/19/2012 DN-60977:A FSP-951 Series NOTIFIER 9 Intelligent Plug-In Photoelectric 0 Smoke Detectors by Honeywell Intelligent/Addressable Devices General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards.The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic I thermistors add 135°F(57°C)fixed temperature thermal sensing on the FSP-951T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan@ and CLIP applications as designated. Features • New modern profile for improved aesthetics. • Designed to meet UL268 7th Edition. FSP-951 in B300-6 Base • Stable communication technique with noise immunity. • Low standby current. • Two wire SLC connection. FSP-951 R installed in a DNR/DNRW, -20oC to 70oC (-4°F to 158°F). • Compatible with FlashScan@ and CLIP protocol systems. UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on suitable for installation in ducts. FlashScan systems). • Optional remote,single-gang LED accessory. Relative Humidity: 10% 93%noncondensing. • Dual LED design provides 360°viewing angle. Thermal Ratings: Fixed-temperature setpoint 135°F(57°C). • Visible bi-color LEDs blink green every time the detector is DETECTOR SPACING AND APPLICATIONS addressed, and illuminate steady red on alarm (FlashScan sys- NOTIFIER recommends spacing detectors in compliance with NFPA tems only). 72. In low airflow applications with smooth ceiling, space detectors • Remote test feature from the panel. 30 feet (9.1 m). For specific information regarding detector spacing, • Walk test with address display (an address on 121 will blink the placement, and special applications refer to NFPA 72. System detector LED: 12-[pause]-1(FlashScan systems only). Smoke Detector Application Guide,document A05-1003,is available • Built-in functional test switch activated by external magnet. at systemsensor.com • Built-in tamper-resistant feature. ELECTRICAL SPECIFICATIONS • Sealed against back pressure. Voltage Range: 15-32 volts DC peak. • Expanded color options. Standby Current(max. avg.): 200pA @ 24VDC (one communica- • SEMS screws for wiring of the separate base. tion every five seconds with LED enabled). • Optional relay, isolator,and sounder bases. LED Current(max.):4.5mA @ 24 VDC("ON"). Specifications Installation Sensitivity: FSP-951 series plug-in detectors use a separate base to simplify • UL Applications: 0.5%to 4.0%per foot obscuration. installation,service,and maintenance. • ULC Applications:0.5%to 3.5%per foot obscuration. Mount base (all base types) on an electrical backbox which is at Size:2.0" (5.3 cm) high; base determines diameter. least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. —B300-6: 6.1" (15.6 cm)diameter. NOTE: 1) Because of inherent supervision provided by the SLC loop, —B501:4" (10.2 cm)diameter. end-of-line resistors are not required. Wiring "T-taps" or branches are For a complete list of detector bases see DN-60981. permitted for Style 4 (Class"B")wiring. 2)When using relay or sounder Shipping weight:3.4oz(96.4g) bases,consult the ISO-X(A)installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. Operating Temperature range: • FSP-951, 0°C to 50°C(32°F to 122°F). • FSP-951 T,0°C to 38°C(32°F to 100°F). DN-60977:A•4/17/18—Page 1 of 3 Agency Listings and Approvals B224BI-WH:White, isolator detector base. These listings and approvals apply to the detectors specified in this B224BI-IV: Ivory isolator detector base. document. In some cases,certain detectors or applications may not B224BIA-WH:White, isolator detector base, ULC listing. be listed by certain approval agencies, or listing may be in process. B224BIA-IV: Ivory isolator detector base, ULC listing. Consult factory for latest listing status, B20OS-WH:White, Intelligent addressable sounder base capable of • UL/ULC Listed: S911 producing sound output in high or low volume with ANSI Temporal 3, • FM Approved ANSI Temporal 4,continuous tone,marching tone,and custom tone. • CSFM: 7272-0028:0503 Uses FlashScan protocol. Product Line Information B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, NOTE: ANSI Temporal 4,continuous tone,marching tone,and custom tone. • Detectors must be mounted to one of the Intelligent Bases listed Uses FlashScan protocol. below. B200SA-WH: Same as B200S-WH, ULC listing. • "A"suffix indicates ULC Listed model. B200SA-IV: Same as B200S-IV, ULC listing. • "IV"suffix indicates FlashScanO and CLIP device. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO FSP-951 White, low-profile intelligent photoelectric sensor, FlashS- Series detector applications. can only. B200SCOA-IV: Ivory Intelligent, programmable sounder base in FSP-951A: Same as FSP-951 but with ULC listing. English/French (required in Canada for ULC applications with SO FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. Series detector applications, ULC listing. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- FSP-951T: White, same as FSP-951 but includes a built-in 135°F 10% with a square wave or its equivalent; designed to meet the (57°C)fixed-temperature thermal device. FlashScan only. NFPA 72 sleeping space requirement. FSP-951TA: Same as FSP-951T but with ULC listing. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- FSP-951T-IV: Ivory,same as FSP-951T but includes a built-in 135°F 10% with a square wave or its equivalent; designed to meet the (57°C)fixed-temperature thermal device. NFPA 72 sleeping space requirement. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. B200SR-WH: White, Intelligent sounder base capable of producing FSP-951 R White, low-profile intelligent photoelectric sensor, sound output with ANSI Temporal 3 or continuous tone. Intended for remote test capable. For use with DNR/DNRW. FlashScan only. retrofit applications. FSP-951 RA: Same as FSP-951 R but with ULC listing. For use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA. sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor, B200SRA-WH: Same as B200SR-WH with, ULC listing. remote test capable. For use with DNR/DNRW. FSP-951 RA-IV:Same as FSP-951 R-IV but with ULC listing. For use B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. with DNRA. B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- 10/o with a square wave or its equivalent; designed to meet the NOTE: For details on intelligent bases,see DN-60981 NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B300-6: hite,6"base,standard flanged low-profile mounting base. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base. 10% with a square wave or its equivalent; designed to meet the 13300A-6: Same as B300-6, ULC listed. NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B30OA-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300:White, replacement flange for B210LP(A)base. B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A) base. base. UL/ULC listed. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501-BL: Black, 4" standard European flangeless mounting base. U.S. single-gang electrical box. For use with B501(A) and B300(A)- UL/ULC listed. 6. B501-IV: Ivory color, 4" standard European flangeless mounting M02-04-00:Test magnet. base. UL/ULC listed. M02-09-00:Test magnet with telescoping handle. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH:White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH:White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3—DN-60977:A•4/17/18 02018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 900 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING&MANUFACTURING QUALITY SYSTEMS For more information,contact Notifier.Phone:(800)627-3473,FAX:(203)484-7118. www.notifier.com Page 3 of 3—DN-60977:A•4/17/18 DN-6724:B3 FCM-1 (A) & FRM-1 A) NOT 1 F 1 E R° Series 0 Control and Relay Modules by Honeywell Intelligent Addressable Devices General FCM-1(A)Control Module: The FCM-1(A)Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.).Addressability allows the FCM-1(A)to be acti- vated, either manually or through panel programming, on a 0 select(zone or area of coverage) basis. FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay T11 Eat PWR,-) O EaaaMiM Module provides the system with a dry-contact output for acti- T,oEatPWR i1 vating a variety of auxiliary devices, such as fans, dampers, „ control equipment,etc.Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- T. tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli ID gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor mation, the panel CPU stops the group poll and concentrates on single points.The net effect is response speed greater than five times that of other designs. FCM-1(A) Features • Built-in type identification automatically identifies these • The FCM-1(A)is configured for a single Class B(Style Y)or devices to the control panel. Class A(Style Z) Notification Appliance Circuit. • Internal circuitry and relay powered directly by two-wire • The FRM-1(A) provides two Form-C dry contacts that SLC loop.The FCM-1(A) module requires power(for horns, switch together. strobes,etc.),or audio(for speakers). • Integral LED "blinks" green each time a communication is Operation received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A) uses one of 159 possible module when activated. addresses on a SLC loop (99 on CLIP loops). It responds to • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- • The FCM-1(A) may be used to switch 24-volt NAC power, tion Appliance Circuit (NAC). The LED blinks with each poll audio(up to 70.7 Vrms). received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) • Wide viewing angle of LED. notification or control circuits. • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The • Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive indication Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- Applications munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. The FCM-1(A) is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The high-level audio (speakers). The FRM-1(A) may be pro- address may be set before or after mounting. The built-in grammed to operate dry contacts for applications such as door TYPE CODE (not settable) will identify the module to the con- holders or Air Handling Unit shutdown, and to reset four-wire trol panel, so as to differentiate between a module and a sen- smoke detector power. sor address. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-I-REL Specifications for FCM-1(A) datasheet(DN-60390)for new Flash5canO releasing applications. Normal operating voltage: 15 to 32 VDC. Construction Maximum current draw: 6.5 mA(LED on). • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC address(01-159). shorted.) DN-6724:B3.2/17/2011—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1(A) External supply voltage(between Terminals T10 and Current Maximum Load T11): Maximum (NAC): Regulated 24 VDC; Maximum Rating Voltage Description Application (Speakers):70.7 V RMS,50W. Drain on external supply: 1.7 mA maximum using 24 VDC 3 A 30 VDC Resistive Non-Coded supply;2.2 mA Maximum using 80 VRMS supply. 2 A 30 VDC Resistive Coded Max NAC Current Ratings: For class B wiring system, the 9 A 110 VDC Resistive Non-Coded current rating is 3A; For class A wiring system,the current rat- ing is 2A. .9 A 125 VDC Resistive Non-Coded Temperature range: 32°F to 120°F(0°C to 49°C). .5 A 30 VDC Inductive Coded Humidity range: 10%to 93%non-condensing. (L/R=5ms) Dimensions: 4.5" (114.3 mm) high x 4" (1 1 A 30 VDC Inductive Coded01.6 mm) wide x (L/R=2ms) 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm)deep box. .3 A 125 VAC Inductive Non-Coded Accessories: SMB500 Electrical Box; CB500 Barrier (PF=0.35) Inductive Specifications for FRM-1(A) 1.5 A 25 VAC (PF=0.35) Non-Coded Normal operating voltage: 15 to 32 VDC. Inductive Maximum current draw: 6.5 mA(LED on). .7 A 70.7 VAC (PF=0.35) Non-Coded Average operating current: 230 pA direct poll;255 pA group poll. Inductive EOL resistance: not used. 2 A 25 VAC (PF=0.35) Non-Coded Temperature range: 32°F to 120°F(0°C to 49°C). NOTE:Maximum(Speakers):70.7 V RMS,50 W Humidity range: 10%to 93%non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x Product Line Information 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x NOTE:"A"suffix indicates ULC Listed model. 2.125" (53.975 mm)deep box. FCM-1(A): Intelligent Addressable Control Module. Accessories: SMB500 Electrical Box; CB500 Barrier FRM-1(A): Intelligent Addressable Relay Module. Agency Listings and Approvals A2143-20: Capacitor, required for Class A(Style Z)operation In some cases, certain modules may not be listed by certain of speakers. approval agencies, or listing may be in process. Consult fac- SMB500: Optional Surface-Mount Backbox. tory for latest listing status. CB500: Control Module Barrier-required by UL for separat- • UL: S635 ing power-limited and non-power limited wiring in the same • ULC: S3705(A version only) junction box as FCM-1(A). • FM Approved NOTE: For installation instructions,see the following documents: • CSFM: 7300-0028:0219 • FCM-1(A)Installation document 156-1169. • MEA: 14-00-E • FRM-1(A)Installation document 156-3502. • FDNY:COA#6067,#6065 • Notifier SLC Wiring Manual,document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6724:133•2/17/2011 DN-6720:E FMM-1 A), FMM-101 A), NOT 1 F 1 E R° FZM-1 (A) &I FDM-1 (A) 0 Monitor Modules with FlashScan@ by Honeywell Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors ® MBE 0 M (FZM-1(A)) o..E. FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D pa;',a s«,•)„ (Class A) or Style B (Class B) circuit of dry-contact inputIAT devices. s" a°M,.•EPow...-.• "a. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75"(6.985 cm)W x 0.65" (1.651 cm)D that "•'u' (�j (�� supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. lo FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. FMM-1(A)(Type H) FDM-1(A)is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B(Class open dry-contact alarm activation devices. May also be used B)dry-contact initiating device circuits(IDCs)at two separate, to monitor normally-open supervisory devices with special consecutive addresses in intelligent,two-wire systems. supervisory indication at the control panel. Monitored circuit FlashScan® (U.S. Patent 5,539,389) is a communication may be wired as an NFPA Style B(Class B)or Style D(Class protocol developed by NOTIFIER that greatly increases the A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor speed of communication between analog intelligent devices. (provided) terminates the Style B circuit. No resistor is Intelligent devices communicate in a grouped fashion. If one required for supervision of the Style D circuit. of the devices within the group has new information, the FMM-1(A) OPERATION panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five Each FMM-1(A)uses one of the available module addresses times that of other communication protocols. on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/normal/short) FMM-1(A) Monitor Module of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control panel. • Built-in type identification automatically identifies this The LED latches steady on alarm (subject to current limita- device as a monitor module to the control panel. tions on the loop). • Powered directly by two-wire SLC loop. No additional FMM-1(A)SPECIFICATIONS power required. • High noise(EMF/RFI)immunity. Nominal operating voltage: 15 to 32 VDC. • SEMS screws with clamping plates for ease of wiring. Maximum current draw: 5.0 mA(LED on). • Direct-dial entry of address: 01 —159 on FlashScan loops; Average operating current: 375 pA (LED flashing), 1 com- 01 —99 on CLIP loops. munication every 5 seconds,47k EOL. • LED flashes green during normal operation (programma- Maximum IDC wiring resistance: 1500 Ohms. ble option)and latches on steady red to indicate alarm. Maximum IDC Voltage: 11 Volts. The FMM-1(A) Monitor Module is intended for use in intelli- gent,two-wire systems,where the individual address of each EOL resistance:47K Ohms. module is selected using the built-in rotary switches. It pro- Temperature range: 32°F to 120°F(0°C to 49°C). vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit(IDC)for normally-open-contact fire alarm and Humidity range: 10%to 93% noncondensing. supervisory devices.The module has a panel-controlled LED Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x indicator. The FMM-1(A) can be used to replace MMX-1(A) 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x modules in existing systems. 2.125"(5.398 cm)deep box. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- DN-6720:E•07/30/2015—Page 1 of 4 FMM-101(A) Mini Monitor Module Temperature range: 32°F to 120°F(0°C to 49°C). • Built-in type identification automatically identifies this Humidity range: 10%to 93% noncondensing. device as a monitor module to the panel. Dimensions: 1.3" (3.302 cm)high x 2.75" (6.985 cm)wide x • Powered directly by two-wire SLC loop. No additional 0.65"(1.651 cm)deep. power required. Wire length: 6"(15.24 cm)minimum. • High noise(EMF/RFI)immunity. • Tinned,stripped leads for ease of wiring. FZM-1(A) Interface Module • Direct-dial entry of address: 01 —159 on FlashScan loops; Supports compatible two-wire smoke detectors. 01 —99 on CLIP loops. • Supervises IDC wiring and connection of external power source. 3 1415 0 1 ADDRESS 0 1 High noise(EMF/RFI)immunity. 12 3 g SEMS screws with clamping plates for ease of wiring. 11 0 4 LOOP O 4 Direct-dial entry entry of address: 01 — 159 on FlashScan 10 5 5 loops,01 —99 on CLIP loops. 9 8 7 6 9 8 7 6 LED flashes during normal operation; this is a program- TENS ONES mable option. • LED latches steady to indicate alarm on command from control panel. Y The FZM-1(A) Interface Module is intended for use in intelli- O Lu U gent, addressable systems, where the individual address of J O W � _J each module is selected using built-in rotary switches. This °Q module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FMM-101(A) Mini Monitor Module can be installed in a The FZM-1(A)can be used to replace MMX-2(A) modules in single-gang junction directly behind the monitored unit. Its existing systems. small size and light weight allow it to be installed without rigid FZM-1(A) APPLICATIONS mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- Use the FZM-1(A) to monitor a zone of two-wire smoke ule is selected using rotary switches. It provides a two-wire detectors. The monitored circuit may be wired as an NFPA initiating device circuit for normally-open-contact fire alarm Style B (Class B) or Style D (Class A) Initiating Device Cir- and security devices. The FMM-101(A) can be used to cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates replace MMX-101(A)modules in existing systems. the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- FMM-101(A)APPLICATIONS nals 8 and 9 for Style D application. Use to monitor a single device or a zone of four-wire smoke FZM-1(A) OPERATION detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be Each FZM-1(A) uses one of the available module addresses used to monitor normally-open supervisory devices with spe- on an SLC loop. It responds to regular polls from the control cial supervisory indication at the control panel. Monitored cir- panel and reports its type and the status (open/normal/short) cuit/device is wired as an NFPA Style B (Class B) Initiating of its Initiating Device Circuit(IDC).A flashing LED indicates Device Circuit. A 47K Ohm End-of-Line Resistor (provided) that the module is in communication with the control panel. terminates the circuit. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module FZM-1(A) SPECIFICATIONS addresses on an SLC loop. It responds to regular polls from Nominal operating voltage: 15 to 32 VDC. the control panel and reports its type and the status (open/ Maximum current draw: 5.1 mA(LED on). normal/short)of its Initiating Device Circuit(IDC). Maximum IDC wiring resistance: 25 Ohms. FMM-101(A) SPECIFICATIONS Average operating current: 270 NA, 1 communication and Nominal operating voltage: 15 to 32 VDC. 1 LED flash every 5 seconds, 3.9k eol. Average operating current: 350 pA, 1 communication EOL resistance: 3.9K Ohms. every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). External supply voltage (between Terminals T10 and T11): Maximum IDC wiring resistance: 1500 Ohms. •Maximum IDC Voltage: 11 Volts. DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. Maximum IDC Current: 450 NA. Current:90 mA per module maximum. EOL resistance:47K Ohms. Temperature range: 320F to 120OF(0°C to 490C). Page 2 of 4—DN-6720:E•07/30/2015 Humidity range: 10%to 93%noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125"(5.398 cm)deep box. tory for latest listing status. FDM-1(A) Dual Monitor Module UL: S635. • ULC: S635. The FDM-1(A)Dual Monitor Module is intended for use in intelli- FM Approved. gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive CSFM: 7300-0028:0219, 7165-0028:0224, addresses. It is capable of monitoring normally open contact fire 7165-0028:0243. alarm and supervisory devices; or either normally open or nor- MEA:457-99-E. mally closed security devices. The module has a single panel- controlled LED. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NOTE: The FDM-1(A)provides two Style B(Class B) 1DC circuits NFS2-3030). ONLY. Style D (Class A) IDC circuits are NOT supported in any Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, application. NFS2-3030). FDM-1(A) SPECIFICATIONS Fire Dept. of New York: COA #6121 (NFS2-640, NFS- Normal operating voltage range: 15 to 32 VDC. 320), COA#6114(NFS2-3030). Maximum current draw: 6.4 mA(LED on). Product Line Information Average operating current: 750 pA(LED flashing). NOTE:"A"suffix indicates ULC-listed model. Maximum IDC wiring resistance: 1,500 Ohms. FMM-1(A): Monitor module. Maximum IDC Voltage: 11 Volts. FMM-101(A): Monitor module, miniature. Maximum IDC Current: 240 pA FZM-1(A): Monitor module,two-wire detectors. EOL resistance:47K Ohms. FDM-1(A): Monitor module, dual, two independent Class B Temperature range: 32°to 120°F(0°to 49°C). circuits. Humidity range: 10%to 93%(non-condensing). SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Manual, PN 51253. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. FDM-1(A)AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A)is set to address"26",then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0, 2,4, 6,or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. A CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A)modules mount directly to a standard 4" (10.16 cm)square, 2.125" (5.398 cm)deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances,and regulations. DN-6720:E•07/30/2015—Page 3 of 4 FlashScan®and NOTIFIERO are registered trademarks and FireWatchT is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6720:E•07/30/2015 DN-2243:B•H-300 ISO-X A) NOT 1 F 1 E R° Fault Isolator Module by Honeywell Intelligent/Addressable Devices General The Notifier ISO-X(A) Fault Isolator Module is used with Noti- fier Onyx and CLIP series Fire Alarm Control Panels (FACPs) to protect the system against wire-to-wire short circuits on the SLC loops. Features • Powered by SLC loop directly, no external power required. • Base mounts on standard junction boxes (4.0"/10.16 cm square by 2.125"/5.398 cm deep). • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is detected. • High noise(EMF/RFI) immunity. • Wide viewing angle of LED. • SEMS screws with clamping plates for ease of wiring. • Opens SLC loop automatically on detection of short, pre- venting the short from causing failure of the entire loop. • Automatically resets on correction of short. • Supports Style 4,6,or 7 wiring. x' 0 Applications ISO-X(A) The Fault Isolator Modules should be spaced between groups of sensors in a loop to protect the rest of the loop. Use to iso- late short circuit problems within a section of a loop so that Construction other sections can continue to operate normally.The ISO-X(A) supports a maximum of 25 devices in-between isolators, The face plate is made of off-white plastic. Includes yellow except when using relay bases or legacy IPX multisensors. LED indicator that pulses when normal and illuminates steady NOTE: ON LOADS PER RELAY BASE AND LEGACY MULTI- when a short is detected. SENSOR DETECTORS/ISOLATORS/ISOLATOR BASES: the maximum number of addressable devices between isolators (or Operation B224BI isolator bases)is 25 devices. Automatically opens circuit when the line voltage drops below i 25 DEVICES four volts. Fault Isolator Modules should be spaced between groups of addressable devices (maximum 25, see notes on isolator isolator page 1) in a loop to protect the rest of the loop. If a short module __________ module occurs between any two isolators,then both isolators immedi- or base or base ately switch to an open circuit state and isolate the groups of 2243devices—f detector module sensors between them. The remaining units on the loop con- tinue to fully operate. B224RB relay bases and legacy IPX-751 multisensor detec- In Style 4 loops, the ISO-X(A) is generally used at each T-tap tors draw more current than all other intelligent devices.When branch, to limit the effect of short circuits on a branch to the calculating the 25-device maximum: B224RB. devices on that branch. The LED indicator is on continuously during a short circuit condition. • B224RB represents 2.5 devices. The ISO-X(A) Fault Isolator Module automatically restores the • IPX-751 in a standard base represents 12 devices. shorted portion of the communications loop to normal condi- • IPX-751 in a relay base represents 14.5 devices. tion when the short circuit condition is removed. • All other addressable devices represent 1 device. See examples on page 2. Installation NOTE: ON MAXIMUM NUMBER OF DEVICES: See the SLC • Mount on a standard junction box (4.0"/10.16 cm square) Manual (PN 51253) for information on loss of addresses due to which is at least 2.125 /5.398 cm deep. current limitations. Each module or base added reduces the . Terminal screws are provided for"in and out'wiring. capacity of address positions in an SLC.All SLC field devices must have been purchased after February 1995 to meet the aforemen- tioned requirements. If the SLC field devices were purchased prior • Surface-mount box is available as an option. to February 1995, each ISO-X(A)used reduces the capacity of an SLC by two address positions. Requirements differ as applied to relay bases(see note above). DN-2243:B•01/05/2012—Page 1 of 2 Specifications Architectual/Engineering Normal operating voltage: 15—32 VDC(peak). Specifications Standby current:450 pA(not isolating) . Fault Isolator Modules shall be provided to automatically iso- late wire-to-wire short circuits on an SLC loop.The Fault Isola- Maximum current draw: 17 mA (device in isolation, LED for Module shall limit the number of modules or detectors that Isola- latched in alarm). may be rendered inoperative by a short circuit fault on the SLC Temperature range:32°F to 120°F(0°C to 49°C). Loop. If a wire-to-wire short occurs, the Fault Isolator Module Relative humidity: 10%to 93%(non-condensing). shall automatically open-circuit (disconnect) the SLC loop. When the short circuit condition is corrected,the Fault Isolator Weight: 5 oz. (150 grams). Module shall automatically reconnect the isolated section of Dimensions: 4.5"H x 4.5"W x 0.25" D (11.43 cm H x the SLC loop. The Fault Isolator Module shall not require any 11.43 cm W x 0.635 cm D). address-setting,and its operations shall be totally automatic. It shall not be necessary to replace or reset an Fault Isolator Agency Listings and Approvals Module after its normal operation. The Fault Isolator Module shall mount in a standard 4.0" (10.16 cm) deep electrical box, In some cases, certain modules may not be listed by certain in a surface-mounted backbox, or in the Fire Alarm Control approval agencies, or listing may be in process. Consult fac- Panel. It shall provide a single LED which shall flash to indi- tory for latest listing status. cate that the Isolator is operational and shall illuminate steadily • UL: S635(UOXX); BP6480(AMCX,APOU). to indicate that a short circuit condition has been detected and isolated. • ULC: S635(OUOXXC, ISO-XA). • FM Approved. Product Line Information • CSFM: 7165-0028:0214; 7165-0028:0224; 7165 0028:0243. NOTE:"A"suffix indicates ULG Listed model. • MEA: 17-96-E; 104-93-E Vol. VI; 290-91-E Vol. V; 317-01- ISO-X: Isolator Module. E;447-99-E. ISO-XA: Isolator Module.Canadian (ULC)version. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 SMB500: Surface Mount Backbox (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C,excluding B210LP(A)). • BSA:578-81-SA. Examples of Device Counts (see notes under Applications) Starts Next Count isolator isolator module module or base detector with detectorwith or base 3 standard base relay base module Counts as... 1 + 3.5 + 1 = 5.5 (2.5+1) (less than 25 total) Notifier®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-2243:13•01/05/2012 DN-6726:D•H-240 NBG-12LX NOTI FI E R° Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices ,General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., . requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except Fire Warden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of _ the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to The NBG-12LX SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi- Addressable Manual Pull Station flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4" (10.16 cm)square electrical box. Installation • Smooth dual-action design. The NBG-12LX will mount semi-flush into a single-gang, dou- • Meets ADAAG controls and operating mechanisms guide- ble-gang, or standard 4" (10.16 cm) square electrical outlet lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. box, or will surface mount to the model SB-10 or SB-1/0 sur- maximum activation force. face backbox. If the NBG-12LX is being semi-flush mounted, • Highly visible. then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position. Once latched, the word "ACTI- Boxes. VATED" (in bright yellow) appears at the top of the handle, • Up to 99 NBG-12LX stations per loop on CLIP protocol while a portion of the handle protrudes from the bottom of the loops. station.To reset the station, simply unlock the station with the e Up to 159 NBG-12LX stations per loop on FlashScan®pro- key and pull the door open.This action resets the handle;clos- tocolloops. ing the door automatically resets the switch. • Dual-color LED blinks green to indicate normal on Each manual station, on command from the control panel, FlashScan®systems. sends data to the panel representing the state of the manual switch.Two rotary decimal switches allow address settings Construction (1 —159 on FlashScan®systems, 1 —99 on CLIP systems). Shell, door, and handle are molded of durable polycarbonate Architectural/Engineering material with a textured finish. Specifications Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so • Shipping Weight: 9.6 oz. (272.15 g) designed that after actual Emergency Operation, they cannot • Normal operating voltage:24 VDC. be restored to normal except by use of a key.An operated sta- • Maximum SLC loop voltage:28.0 VDC. tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of • Maximum SLC standby current: 375 NA. red-colored polycarbonate material with clearly visible operat- • Maximum SLC alarm current: 5 mA. ing instructions provided on the cover. The word FIRE shall • Temperature Range:32°F to 120°F(0°C to 49°C) appear on the front of the stations in white letters, 1.00 inches • Relative Humidity: 10%to 93%(noncondensing) (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/0;or semi-flush • For use indoors in a dry location mounting on a standard single-gang, double-gang, or DN-67260•4/13/2012—Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key IOC King Teature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR:Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM: 7150-0028:0199. • FDNY: COA#6085(NFS2-640), COA#6098(NFS2-3030). • BSMI:CI313066760047. • U.S.Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO and FlashScanO are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-67260•4/13/2012 DN-6643:A1 •1-410 NBG.12 Series NOTI FI E R° Non-Coded Conventional Manual 0 Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices General The NOTIFIER NBG-12 Series is a cost-effective, feature- . packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind.The NBG-12 Series features a variety of mod- els including single-and dual-action versions. The NBG-12 Series provides an alarm initiating input signal to conventional fire alarm control panels (FACPs) such as the SFP Series, and to XP Transponders. Its innovative design, durable construction, and multiple mounting options make the NBG-12 Series simple to install,maintain,and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull-force. 6643cov.;P9 • Meets UL 38,Standard for Manually Actuated Signaling Boxes. • Easily operated (single- or dual-action, model dependent), Construction yet designed to prevent false alarms when bumped, shaken, or jarred. • Cover, backplate and operation handle are all molded of • PUSH IN/PULL DOWN handle latches in the down position to durable polycarbonate material. clearly indicate the station has been operated. • Cover features white lettering and trim. • The word "ACTIVATED" appears on top of the handle in • Red color matches System Sensor's popular SpectrAlert@ bright yellow,further indicating operation of the station. Advance horn/strobe series. • Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. Operation • Braille text included on finger-hold area of operation handle The NBG-12 manual pull stations provide a textured finger-hold and across top of handle. area that includes Braille text. In addition to PUSH IN and PULL • Multiple hex-and key-lock models available. DOWN text,there are arrows indicating how to operate the sta- • U.S. patented hex-lock needs only a quarter-turn to lock/ tion,provided for non-English-speaking people. unlock. Pushing in and then pulling down on the handle activates the • Station can be opened for inspection and maintenance with- normally-open alarm switch. Once latched in the down position, out initiating an alarm. the word"ACTIVATED"appears at the top in bright yellow,with a • Product ID label viewable by simply opening the cover; label portion of the handle protruding at the bottom as a visible flag. is made of a durable long-life material. Resetting the station is simple: insert the key or hex (model • The words"NORMAL"and"ACTIVATED"are molded into the dependent),twist one quarter-turn, then open the station's front plastic adjacent to the alarm switch(located inside). cover, causing the spring-loaded operation handle to return to • Four-position terminal strip molded into backplate. its original position. The alarm switch can then be reset to its • Terminal strip includes Phillips combination-head captive 8/32 normal (non-alarm) position manually (by hand) or by closing screws for easy connection to Initiating Device Circuit(IDC). the station's front cover,which automatically resets the switch. • Terminal screws backed-out at factory and shipped ready to accept field wiring(up to 12 AWG/3.1 mm2). Specifications • Terminal numbers are molded into the backplate, eliminating PHYSICAL SPECIFICATIONS: the need for labels. • Switch contacts are normally open. pull station SB-10 SB-1/0 WBB WP-10 • Can be surface-mounted (with SB-10 or S113-1/0) or semi- H 5.500 in. 5.500 in. 5.601 in. 4.25 in. 6.000 in. flush mounted. Semi-flush mount to a standard single-gang, (13.97 cm) (13.97 cm) (14.23 cm) (10.79 cm) (15.24 cm) double-gang,or 4" (10.16 cm)square electrical box. 4.121 in. 4.125 in. 4.222 in. 4.25 in. 4.690 in. • Backplate is large enough to overlap a single-gang backbox W (10.467 cm) (10.478 cm) (10.72 cm) (10.79 cm) (11.913 cm) cutout by 1/2"(1.27 cm). Optional trim ring(BG12TR). D 1.3 in. 1.375 in. in. 1.75 in. 2.000 in. • (3.531 cm) 1 (3.493 cm) (3.663.66 cm) (4.445 cm) (5.08 cm) • Spanish versions(FUEGO)available(NBG-12LSP,NBG-12LPSP). 6643dim2.tbl • Designed to replace the legacy NBG-10 Series. • Models packaged in attractive, clear plastic (PVC), clam- ELECTRICAL SPECIFICATIONS: shell-style, Point-of-Purchase packages. Packaging includes Switch contact ratings:gold-plated; rating 0.25 A @ 30 VAC or a cutaway dust/paint cover in shape of pull station. VDC. Auxiliary contact circuit (Terminals 3 &4, NBG-12LA): rated to 3.0 A @ 30 VAC or VDC. DN-6643:A1 •04/22/08—Page 1 of 2 ENGINEERING/ARCHITECTURAL SPECIFICATIONS NBG-12LPSP: Same as NBG-12LPS with English/Spanish Manual Fire Alarm Stations shall be non-code, with a key- or 0)labeling. hex-operated reset lock in order that they may be tested,and so NBG-12LOB Dual-action pull station with key lock, outdoor designed that after actual Emergency Operation,they cannot be applications listings(NBG-12LO),and backbox.Includes SB-1/0 restored to normal except by use of a key or hex. An operated indoor/outdoor backbox, and sealing gasket. Model will also station shall automatically condition itself so as to be visually mount to WP-10 weatherproof backbox in retrofit applications. detected as activated. Manual stations shall be constructed of NOTE: NBG-121-0 not available separately; red colored LEXAN (or polycarbonate equivalent) with clearly NBG-12LO+approved backbox=NB0-12L06. visible operating instructions provided on the cover. The word Outdoor applications listings apply to NBG-12LOB combination. FIRE shall appear on the front of the stations in white letters, NBG-12LA: Dual-action pull station with key lock and annuncia- 1.00 inches (2.54 cm) or larger.* Stations shall be suitable for for contacts. surface mounting on matching backbox SB-10 or SIB-I/O; or SB-10: Surface-mount backbox, metal. semi-flush mounting on a standard single-gang,double-gang,or SB-I/O: Surface-mount backbox, plastic. (Included with NBG- 4" (10.16 cm)square electrical box,and shall be installed within 12LOB.) the limits defined by the Americans with Disabilities Act(ADA)or per national/local requirements.Manual Stations shall be Under— writers Laboratories listed. WP-10: Outdoor use backbox. NOTE:*The words"FIRE/FUEGO"on the NBG-12LSP and NBG- 17021: Keys,set of two. (Included with key-lock pull stations.) 12LPSP shall appear on the front of the station in white letters, 17007: Hex key,9/64". (Included with hex-lock pull stations.) approximately 3/4"(1.905 cm)high. NOTE: For addressable NBG-12LX models, see data sheet ON-6726. Pre-Signal Models 1.390" The NBG-12LPS and NBG-12LPSP pull stations are non-coded (3.531) Dimensions manual pull stations which provide a FACP with two normally open alarm initiating input signals."Pre-signal"input is activated by pushing in,then pulling down,the dual-action handle.A"gen- Strip Lengre eral"alarm input signal can be manually activated via a momen tary rocker switch mounted inside the unit. This general alarm switch can only be accessed by opening the cover with the sup- 1.0001, plied key/lock. See diagram at right. (z Agency Listings and Approvals The listings and approvals below apply to the NBG-12 Series o.750" pull stations. In some cases,certain modules may not be listed (1.so5> 5.500" by certain approval agencies, or listing may be in process. Con- (13.970) sult factory for latest listing status. 3 • C(UL)US Listed:file S692. (cm) • CSFM approved:file 7150-0028:199. • FM approved(except NBG-121-PS, NBG-12LPSP). • MEA approved:file 67-02-E(NBG-12, N13G-12L, NBG-12L06, NBG-12LA). • Lloyd's Register type approved: file 93/60141 (E3) (NB6-12, J NBG-12LPS N60-12L, N60-12LA,NB0-12L06, NBG-12S). • U.S.Coast Guard approved:files 161.002/23/3(AFP-200 with NB6-12, NBG-12L, NB6-12S); 161.002/42/1 (NFS-640 with PRODUCT NBG-12, NBG-12L IA13FI, NBG-12S); 161.002/27/3 (AFP1010/ DEN ON LABEL AM2020 with NBG-12, NBG-12L, NBG-12S). • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; ROCKER MPS TOGGLE 6,632,108. SWITCH NOR SWITCH for General ® for Pre-Signal Alarm ACr function Product Line Information notification ��gTED NBG-12S: Single-action pull station with pigtail connections, E hex lock. 3 NBG-12: Dual-action pull station with SPST N/O switch, screw 1 terminal connections, hex lock. NBG-12L: Dual-action pull station with SPST N/O switch, screw terminal connections, key lock. NOTIFIERO,SpectrAlertO Advance,and System SensorO are registered trademarks of Honeywell International Inc. NBG-12LSP: Same as NBG-12L with English/Spanish (FIRE/ 02008 by Honeywell International Inc.All rights reserved.Unauthorized use FUEGO) labeling. of this document is strictly prohibited. NBG-12LPS: Dual-action pull station with pre-signal option. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING S MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6643:A1 •04/22/08 (P' POTTER IRTS-OIRTS-C The Symbol of Protection ROOM TEMPERATURE SWITCH Listings: UL,cUL Listed Enclosure: White ABS Dimensions: 2 1/16"W x 3 7/16"L x 1 1/4"H (5,2cm W x 8,7cm L x 3,2cm H) Sensor: Epoxy sealed stainless steel case,bi-metallic operating mechanism. Contacts: Silver clad,available normally open or normally closed Electrical Rating: 1 Amp at 24VDC Temperature Setting: 40'f5°F(4,5°f3°C) Terminals: Screw Terminals Mounting: Wall Mount,Surface RTS-0 Stock No. 1010108 RTS-C Stock No. 1010109 c �L us LISTED Application Description The RTS Series complies with the requirements of NFPA 13 and 72 Each unit consists of a bi-metal operating mechanism, featuring for a room temperature switch to operate at 40°F to protect a dry pipe hermetically sealed precious metal contacts, N.O. or N.C., which valve from freezing. The RTS can also be used for other temperature automatically reset for repetitive operation, eliminating the need for detection applications. sensing element replacement. Small compact design,highly resistant to vibration and corrosion.Easily Operation installed using the enclosed hardware or adhesive mounting pad. The normally open detector, RTS-O,will close the contact when the Screw terminals permit easy installation in single or multiple temperature drops below 40°F(4,5°C). The normally closed detector, detector circuits. RTS-C,will open the contact when the temperature drops below 40°F (4,5°C).The detector will automatically reset to the normal state when Features: the temperature rises above 40°F(4,5°C). • Easily installed The RTS Series Room Temperature Sensors are precision engineered, • Completely sealed sensor,moisture and vapor resistant designed and manufactured for commercial or residential use. • Highly resistant to vibration and corrosion • Highly sensitive to temperature changes • No sensitivity loss due to aging • Repetitive operation without the need to replace sensing elements • Small compact design • Precision and quality at low cost Customer: Project: Engineer: Architect: PRO or PO: QTY: Potter Electric Signal Co.,LLC•St. Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 • Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8820013-REV J PAGE 1 OF 1 6/11 (E) POTTER PSN series The Symbol of Protection Power Supplies Features • PSN-64 has 6 amps regulated with 4 outputs • PSN-106 has 10 amps regulated with 6 outputs • May be configured as up to three class"A"Style"Z" notification circuits - • Two Trouble relays(5A at 30VDC)General System Trouble O',, i (programmable for AC delay)Low AC Trouble with optional delay settings • Diagnostic LED's Status LED's for Active NAC and NAC Trouble conditions. • Quadrasync feature synchronizes strobes from AMSECO, Gentex,Cooper-Wheelock and System Sensor. • Configurable output circuits(DIP switch sets options for each circuit) • Reference EOL allows 2K—27K EOL value to be used • Pass Thru mode allows the outputs to match the input signal from FACP SIGNALING C UL US LISTED Description the same pattern.This input pass through can be selected on each The PSN series of notification power supplies offers reliable output independently.The power supply contains simple dipswitch programming and LED indicators providing the installer the ability notification power with unprecedented versatility.The power supplies to correct any possible faults.A Trouble Memory is provided to offer either 6 or 10 amps of continuous power through 4 or 6 outputs allow an installer to review past troubles and make the necessary respectively.Each output is rated at 3 amps and it may be used repairs.Each output has an LED to pinpoint the exact circuit where continuously without any derating.The power supply operates on a trouble may have occurred.Relays are provided for monitoring the either 120 VAC or 220 VAC power input and has a regulated 24 VDC general system and AC failure.Each output and be independently output.In addition,the power supply can charge up to 55 AH batteries configured for various applications and installations.Each output can and leads the industry in housing up to 18 AH batteries.The cabinet be independently configured for Class A or Class B operation,constant is constructed out of 18 gauge cold rolled steel and has a durable red power,ANSI Temporal Code 3,Single,Multiple or Combo Inputs or powder coat finish.In addition,a key lock is provided for securing the Door Holder Power. door.Ample electrical knockouts are provided on the sides and the top, allowing the installer options for running wires and maintaining the Technical Specifications correct separations. The power supply offers an industry leading Quadrasync function Size(H x w x D) 16 1/8"w x 16 3/'W x 3/"D that allows for multiple strobe circuits of different brands to be Enclosure Eighteen(18)gauge sheet steel with hinged,locked door synchronized to flash at the same time.The power supply can have 120VAC @ 6OHz four different brands each connected to its own circuit and all the Power Input 220/240VAC @ 50Hz strobes flash together.Each output can independently be configured to 5.1 Amps @ 120 VAC provide one of four synchronizations or steady power.This provides 2.5 Amps @ 240 VAC unequivocal flexibility in new and retrofit installations.The power Current 75mA standby&Alarm(no external load) supply can be configured to synchronize AMSECO®,Gentex®, Input voltage 15mA @ 8—33 VDC Wheelock®and System Sensor®strobe devices.Each output can Trigger be configured to the same sync protocol or set independently.In Terminals 18-12 AwG addition,the power supply has an input Pass Thru mode which 32'F to 120°F(0°C to 49°C)with a maximum humidity of 93% Temperature allows the outputs to follow the input signal from anon-supported non-condensing synchronization protocol.The power supply will recognize the type NAC Output 3 Amp max per NAC,Regulated of input being supplied and pass this through to the outputs with Battery charging 27.3 @ 1A,can support 7—55Ah batteries Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8910013-REV E 05/21 PAGE 1 OF 3 (E) POTTER PSN series The Symbol of Protection Power Supplies PSN-106 Wiring Diagram 4 120/240 VAC GND FAULT N o Jumper Position DETECT ENABLE ON ° ° ° OFF 120VAC 50Hz-6OHz 240VAC 50Hz-6OHz Black Connect to separate White ZZ unswitched AC circuit Ground Status LEDs NACI NAC2 NAC3 NAC4 NACS NAC6 DCPWR "S7 S8 Q �� O• • • • • • • 0 ' ® ® ® BBBBB�B� BBB9B9BB H N comet e 0 Fuse ❑ o Ms2 p a @ee s3 ❑❑ .o �❑ 0 0 0 Factory Installed 0 0 o @RS4 Interconnect. ❑ ❑ ❑ ❑ ❑ ❑AC Power O 0���� SS Low Battery O Grid Fault ❑ El ❑ ❑ El 0 8���� S6 Comm L] El8 Bulk Options � � � � � � C] 0 ❑ ❑ ❑ p NAC] NAC2 NAC3 NAC4 NAC5 NAC6 CPWR REF 1N1 IN2 Q O LOW AC TROUBLE O + + + + + + + + NC COM NO NC COM NO Q1—Battery+ O Common relays are Battery- Optional E.O.L. non-power limited. ° Reference E.O.L. E.O.L. DC Power Trigger Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Battery connection(non-power limited). supply is triggered.There is no current draw in Standby Mode. Use two(2)12V batteries connected in series. Ordering Information Model Description Stock No. PSN-106 10 A Power Supply,6 NAC Circuits, 3006437 Red Enclosure PSN-106B 10 A Power Supply,6 NAC Circuits, 3006446 Black Enclosure PSN-64 6 A Power Supply, 4 NAC Circuits, 3006436 Red Enclosure Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8910013-REV E 05/21 PAGE 2 OF 3 (E) POTTER PSN series The Symbol of Protection Power Supplies Engineering Specifications The contractor shall supply and install the Potter PSN power supply. The power supply shall operate on either 120 or 240 VAC input. The panel shall be capable of continuous load power without any degradation to the main supply or the distribution board.The cabinet shall be capable of housing up to 18AH batteries and the panel shall be capable of charging up to 55 AH batteries in an external cabinet. The panel shall have dip switches for simplistic configuration of the system and LEDs to provide visual indication to the installer of the status of the system.The dip switches shall allow for AC power delay selection,Class A/B operation per output,Door Holder Power options, constant auxiliary power,trigger input type,ANSI Code 3 Temporal Code, Pass Thru (input tracking),AMSECOO sync, Gentex® Sync, System Sensor® Sync or Wheelock® sync. The LEDs shall provide indication of communication between the power supply and distribution circuit assemblies. The LEDs shall have distinct flash patterns to provide further indication of the troubles present.The panel shall have selectable Trouble Memory to provide the installer an indication that a past trouble existed on a circuit for diagnostic purposes. Each output of the power supply shall be capable of 3 amps of continuous power without degradation overtime. The power supply shall provide for multiple circuits of strobe appliances. The power supply shall synchronize the flashes of any of the above listed strobe appliances on a per circuit basis. Up to four different strobe circuits may be connected and all the strobes shall flash in unison as required by UL 864. In addition to this Quadrasync feature, the panel shall allow any of the four above mentioned sync patterns as an input and pass this signal through and synchronize the outputs to match the input flash pattern. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8910013-REV E 05/21 PAGE 3 OF 3 SYSTEM SENSOR° 5600 Series l Mechanical Heat Detectors 5601P System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, i and for non-life-safety installations where smoke detectors are inappropriate. cc,, 151°ii 5621 Features Multiple configurations.The 5600 series offers a full-line of • Multiple configurations for installations: configurations to accommodate a broad range of applications. Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations(Model 5601P) • Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, • Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5"and 4"Octagonal when used with a square to round plaster ring.The reversible —4-square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. • Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/ rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings @ FM UDC 0 AR i LISTED APPROVED S2101 3016008 CSG?o 7270-1653:0167 Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90oC),and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor.The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P,5603,5621,and 5623: 100°F(38°C) 5602,5604,5622,and 5624: 150OF(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623: 135°F(57°C) 5602,5604,5622,and 5624: 194OF(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 150F(8.3°C)rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC/3A Ratings 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1A Input Terminals 14-22 AWG e "yd O O O O O 5601 P 5602,5622 5603,5623 5604,5624 5621 Ordering Information MethodIdentification .. Model Circuit on Exterior Rating Activation Ceiling* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) `NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Product specifications subject to change without notice.Visit systemsensorcom Phone:800 SENSOR2•Fax:630 377 6495 or current product information,including the latest version of this data sheet. SENSOR" www.systemsensor.com SPDS30001.7/13 SYSTEM sevs0a, Duct Smoke Detection System Sensor combines an impressive collection of innovations designed to save you time and money and provide the flexibility you need in the field.An adjustable housing overcomes mounting constraints. Plug-in,tool-free sampling tubes speed installation.The front cover test/reset button simplifies test/maintenance.With these features and many more, InnovairFlex is reshaping duct smoke detection. D4120 DUCTSD D412OW Photoelectric duct smoke detector with 2:1 Sensor to Photoelectric duct smoke detector with cover integrated Watertight photoelectric duct smoke detector Power Capability smoke test port 4-wire;100-4,000 ft/min;—4°to 158°F(-20°to 70°C); 4-wire;100-4,000 ft/min;—4°to 158'F(-20°to 70'C); 4-wire;100-4,000 ft/min;—4°to 158'F(-20°to 70°C); NEMA 4;24 VAC/DC or 120 VAC;65mA max.at 24 VDC; 24 VAC/DC or 120 VAC;65mA max.at 24 VDC; 24 VAC/DC or 120 VAC;65mA max.at 24 VDC; 2 Form C Auxiliary Relays 2 Form C Auxiliary Relays 2 Form C Auxiliary Relays ; D4240 DUCTSD240 D2 Photoelectric duct smoke detector with 2:1 Sensor to Photoelectric duct smoke detector with cover integrated Photoelectric duct smoke detector Power Capability smoke test port 2-wire;100-4,000 ft/min;—4°to 158'F(-20°to 70'C); 4-Wire;100-4,000 tt/min;-4°to 158'F(-20°to 70'C); 4-Wire;100-4,000 ft/min;-4°to 158'F(-20°to 70'C); 12/24 VDC;130mA max. 24 VAC/DC or 240 VAC;65mA max.at 24 VDC; 24 VAC/DC or 240 VAC;65mA max.at 24 VDC; 2 Form C Auxiliary Relays 2 Form C Auxiliary Relays M D4P120 2D51 Photoelectric sensor-only component Power-board-only component Photoelectric no-flow/low-flow smoke detector 4-wire;100-4,000 ft/min;—4°to 158'F(-20°to 70°C); 4-wire;—4°to 158'F(-20°to 70'C); 4-wire;0-4,000 ft/min;—4°to 158'F(-20°to 70'C);24 24 VAC/DC or 120 VAC;65mA max.at 24 VDC 24 VAC/DC or 120 VAC;65mA max.at 24 VDC; VAC/DC or 120 VAC w/13210LP;75mA max.; 2 Form C Auxiliary Relays 1 Form A&1 Form C Auxiliary Relay ti\It�F.F tiMUF.I RTS2 RTS2-AOS AOS SENS-RDR MHW Multi-signaling accessory Multi-signaling accessory with Add-on Strobe Sensitivity Reader Mini Horn,White without strobe add-on strobe Displays sensitivity and status UL S4011 20-29 VDC;UL S2522 20-29 VDC;UL S2522 indication readings of compatible smoke detectors.For use with RTS2 remote test accessories MHR APA151 RA10OZ RTS151 RTS151 KEY Mini Horn,Red Remote annunciator Remote annunciator Remote test station Remote test station UL S4011 with piezo alert 3.1-32 VDC; 2.8-32 VDC with key test/reset 16-33 VDC;UL S4011 UL S2522 (Alarm LED);UL S2522 UL S2522 ■ MAG-X DST ETX Accessory magnet used Sampling Tubes Exhaust Tube for testing InnovairFlex DST1-ducts up to 1 foot DST5-ducts 4 to 8 feet 12 inches in length Sensor Head - uc s o ee DST10-ducts 8 to 12 feet DST3-ducts 2 to 4 feet SYSTEM SENSOR® 02015 System Sensor.All Rights Reserved. advanced ideas.advanced solutions:- Product specifications subject to change without notice. Visit systemsensor.com/flex for current product information. www.systemsensor.com/flex HVFL70901•12/15 SYSTEM SENSOR° r L-Series and L-Series with LED Indoor Selectable F I I I R 9 Horns, Strobes and E Horn Strobes System Sensor L-Series and L-Series with LED audible r visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter(DVM)diagnostic test points for Horn strobes,and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15,30,75,95, wall or ceiling mount,standard or compact sizes, red or white color 115, 150,and 177 choices, bezel kits for alternate markings and languages,and LED • Rotary switches for candela,tone and volume selections color lenses for distinctive visual signaling. In addition,installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela,tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert,SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify • Synchronization through use of UL approved power supplies that installation.All devices feature plug-in designs with minimal intrusion support System Sensor Sync protocol or System Sensor MDL3 into the back box,making installations fast and foolproof while Sync Module virtually eliminating costly and time-consuming ground faults.The • Horns,Strobes and Horn Strobes listed for wall or ceiling use universal mounting plate includes an onboard shorting spring,so installers can test wiring continuity before the device is installed. In addition,the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without SIGNALING SIGNALING removing the appliance from the wall or ceiling.The DVM test points F M ti are discreetly located on the face of the notification appliance which 60 U5 LISTED LISTED LISTED APPROVED enable faster troubleshooting and end of line(EOL)voltage checks Horn Strobes Horns: Horns; 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: 54011 S4011 FM23FPUS0195 7135-1653:0503 55512,54011 7135-1653:0526 during troubleshooting. AVDS916-01•10/03/2023•Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage,LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage,Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range,LED Strobes and Horn Strobes 16 to 33 V(24 V nominal) Operating Voltage Range,Horns 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UUULC Current Draw Data, Horn Tones, and Sound Output Data UIJULC Maxmimurn Strobe Current Draw(mA) UUULC Maxmimum Horn Current Draw(mA RMS) Candela 16-33 Volts 8-17.5 Volts 16-33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UUULC Maximum Horn Strobe Current Draw(mA)and Sound • .: Current Draw(mA RMS),Horn Strobe, Sound Candela Range(15-185 cd) Output (d BA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01•10/03/2023•Page 2 L-Series with LED Dimensions:Wall-Mounted Equipment 2.07" (63 mm) -� 3.46" 3.46" 1.25' m 88 mm 1.2 3.57" 1 88 mm 32 mm (9.1 cm) (3.9 c cm) (31.8 mm) no °• 00o• 5.38"5.27' o00o Oo00000o0o0op133.9 mm3..27" 3.7 cm)133.9014Y I I lei 2, L�® �� A0617-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls(SBBGRL,SBBGWL) 2.07" 4.7" 1. 4.T' 1 B mm) 119 mm 32 mm (424 ) 1.85" 119 mm 1.25" 14.8" (4.69 cm) 06°0°0°0°0010 a�o LIP 00000•.°oo. •d0°a oo 00000°o°a°o •o a o•4 a 00000 004004 144 5.mm aoo 0 0 5.67' .a.o. r .o.o.o0 5.78" O 1.mm oa0000o0�00 (14.68 CM)00000000000 ° o0000000000 1® ®® A0613-00 A0549-00 A0554-01 Strobes,Horn Strobes Horn Surface Mount Back Box for Walls for Walls(SBBRUSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 2.07" 6.92"diam. 2.5' (52.6 mm) (175.77 mm) (64 mm) 6.83"diam. 1.25" (173.5 mm) (31.8 mm) O O o C= o- O C=) 0 0 0 ® o o Q o 0 o 0 A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings(SBBCRL,SBCWL) AVDS916-01•10/03/2023•Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P21FILED 2-Wire,Horn Strobe,Wall,Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire,Horn Strobe,Wall,Red,Bilingual LENS-133 Lens LED Blue Wall/Ceiling P2WLED 2-Wire,Horn Strobe,Wall,White LENS-133 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire,Horn Strobe,Wall,White,Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire,Compact Horn Strobe,Wall,Red Accessories P2GRLED-B 2-Wire,Compact Horn Strobe,Wall,Red,Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire,Compact Horn Strobe,Wall,White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire,Compact Horn Strobe,Wall,White, SBBWL Wall Surface Mount Back Box,Red Bilingual SBBWL Wall Surface Mount Back Box,White P2RLED-P 2-Wire,Horn Strobe,Wall,Red,Plain SBBGRL Compact Wall Surface Mount Back Box,Red P2WLED-P 2-Wire,Horn Strobe,Wall,White,Plain SBBGWL Compact Wall Surface Mount Back Box,White P2RLED-SP 2-Wire,Horn Strobe,Wall,Red,FUEGO TRC-2 Universal Ceiling Trim Ring,Red P2WLED-SP 2-Wire,Horn Strobe,Wall,White,FUEGO TRC-2W Universal Ceiling Trim Ring,White PC2RLED 2-Wire,Horn Strobe,Ceiling,Red SBBGRL Ceiling Surface Mount Back Box,Red PC2RLED-B 2-Wire,Horn Strobe,Ceiling,Red,Bilingual SBBCWL Ceiling Surface Mount Back Box,White PC2WLED 2-Wire,Horn Strobe,Ceiling,White Bezelst PC2WLED-B 2-Wire,Horn Strobe,Ceiling,White,Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe,Wall,Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe,Wall,Red,Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe,Wall,White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe,Wall,White,Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe,Compact,Wall,Red SGRLED-B Strobe,Compact,Wall,Red,Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe,Compact,Wall,White All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. SGWLED-B Strobe,Compact,Wall,White,Bilingual All-ALERT models have"ALERT'marking on cover. SRLED-P Strobe,Wall,Red,Plain All-B models have"FIRE/FEU"marking on cover for use in Canadian SWLED-P Strobe,Wall,White,Plain applications. SRLED-SP Strobe,Wall,Red,FUEGO Amber lenses are not for use in Canadian applications SWLED-CLR- Strobe,Wall,White,ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe,Wall,White,ALERT,Amber Lens SCRLED Strobe,Ceiling,Red Notes for Bezels: SCRLED-B Strobe,Ceiling,Red,Bilingual tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL SCRLED-P Strobe,Ceiling,White,Plain (ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP SCWLED Strobe,Ceiling,White (FUEGO),-SPE(FUEGO/FIRE). SCWLED-B Strobe,Ceiling,White,Bilingual SCWLED-P Strobe,Ceiling,White,Plain SCWLED-CLR- Strobe,Ceiling,White,ALERT ALERT L-Series Horns HRL* Horn,Red HRLA* Horn,Red,Plain, ULC HWL* Horn,White HWLA* Horn,White,Plain,ULC HGRL* Compact Horn,Red HGRLA* Compact Horn,Red,Plain,ULC HGWL* Compact Horn,White HGWLA* Compact Horn,White,Plain,ULC 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. www.systemsensor.com SYSTEM 3333 Unity Drive, Mississauga,ON L5L 3S6 Canada ©2023 System Sensor. Phone:800 SENSOR2•Fax:905 812-0771 Product specifications subject to change without notice.Visit systemsensorcom SENSOR w or current product information,including the latest version of this data sheet. www.systemsensor.ca AVDS916-01.10/03/2023 SYSTEM SENSOR° L-Series Speakers and L-Series with LED � Speaker Strobes '''''" it��,���. _ ., ��`�� 111�i4 � , System Sensor L-Series and L-Series with LED audible visible notification products are rich with features , guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of speakers Digital Volt Meter(DVM)diagnostic test points for Speaker and speaker strobes in the industry with lower current draw and • Strobes modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela • Common aesthetics across the L Series platform range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 • Field-selectable candela settings on ceiling units: 15,30,75, Flexible design options meet virtually any application requirement: 95, 115, 150,and 177 wall or ceiling mount, red or white color choices, bezel kits for • Rotary switches for candela,speaker voltage(25 and 70.7 alternate markings and languages,and LED color lenses for Vrms)and power settings(1/4,1/2, 1,and 2 watts) distinctive visual signaling. In addition, installers can easily adapt • Mounting plate provides plug-in design for easier installation devices using field selectable candela,using rotary switches. and shorting springs to check wiring continuity The L-Series and L-Series with LED line is developed to simplify • Electrically compatible with legacy SpectrAlert,SpectrAlert installation.All devices feature plug-in designs with minimal intrusion Advance and L-series devices at 16-33 VDC into the back box,making installations fast and foolproof while • Synchronization through use of UL approved power supplies virtually eliminating costly and time-consuming ground faults.The that support System Sensor Sync protocol or System Sensor universal mounting plate includes an onboard shorting spring,so MDL Sync Module installers can test wiring continuity before the device is installed. • Speakers and Speaker strobes listed for wall or ceiling use • No extension ring required The low harmonic distortion of the speaker offers high fidelity sound • Speakers offer high fidelity and high volume sound output output while offering high volume sound output for use in high • 520 Hz capable with compatible Fire alarm control panel(FACP) ambient noise applications. In addition,the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without removing the appliance from the wall or ceiling.The DVM test points Agency Listings are discreetly located on the face of the notification appliance which SIGNALING enable faster troubleshooting and end of line(EOL)voltage checks while greatly reducing the risk of misplacing or damaging appliances C&US U� CLISTED°` FM during troubleshooting. LISTED LISTED APPROVED Speaker-Strobes: Speakers: Speakers: 3057383 7125-1653:0533 S4048 S4048 S4048 3057493 7135-1653:0532 7320-1653:0505 AVDS-62174:A•08/29/2024•Page 1 Product Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Power 1/4,1/2, 1,2 Watts Frequency Range 400 to 4000 Hz Maximum Supervisory Voltage(Speakers) 50 VDC Maximum Supervisory Voltage(Strobe) 33 VDC Strobe Flash Rate 1 Flash Per Second Nominal Voltages,Speakers 25 Volts or 70.7 Volts(nominal) Nominal Voltage,Strobe Regulated 24 VDC Operating Voltage Range,Strobe 16 to 33 VDC Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wall Speaker Strobes(including lens) 6.51 x 5.00" W x 2.3" D (165.1mm L x 127mm W x 58.4mm D) Wall Speaker Strobes(including lens)with SBBSPRUWL Surface 6.62"L x 5.12"W x 4.55"D(168.1 mm L x 130mm W x 115.5mm D) Mount Back Box Ceiling Speaker Strobes(including lens) 6.8"diameter x 2.33"D(172.7mm x 59.2mm) Ceiling Speaker Strobes(including lens)with SBBCRUWL Surface 6.9"diameter x 4.83"D(176mm x 122.7mm) Mount Back Box Wall SPL Speakers 6.51 x 5.00"W x 0.97"D(165.1 mm L x 127mm W x 23mm D) Wall Speakers with SBBSPRUWL Surface Mount Back Box 6.62"L x 5.12"W x 3.2"W(168.1mm x 130mm x 81.2mm) Ceiling SPC Speakers 6.8"diameter x 1.0"D(173mm x 25mm) Ceiling Speakers with SBBCRUWL Surface Mount Back Box 6.9"diameter x 3.5"D(176mm x 89mm) NOTE:SBBSPRUWL Surface Mount Back Box intended for speaker strobes and speakers. OutputMinimum Speaker Strobe Sound 1/4W 1/2W 1 W 2W UL Reverberant(dBA @10 ft) 76 79 82 83 UL Anechoic(dBA @10 ft) 76 79 82 83 Minimum Speaker Only Output 1/4 W 1/2 W 1 W 2 W UL Reverberant(dBA @10 ft) 79 82 85 88 UL Anechoic(dBA @10 ft) 79 82 85 88 UL/ULC Maximum Strobe Current Draw (mA) UUULC Max Strobe Current Draw Candela Rating 16 to 33 Volts DC 15 18 30 22 75 70 95 75 110 85 115 90 135 105 150 110 177 115 185 120 FCP" (future) "FCP Fire Control Panel,future use AVDS-62174:A•08/29/2024•Page 2 L-Series Dimensions 5.00 W'11 1d21 11271 0.97" 1.63" 6" (24.64 mm) (41.66 mm) (127 mm) p°00 0 A O O B e 8 A 00°p p000Ao eA0000 11 0000°0"O.oao°o0o° ° p ®® p °A0000°00000°00000° p 10 00p0°° °0p'00 00 °0®® Sg Oo080a08000B080B11 1 80 00 600 O00 0° 0°0® 0 OI OOBA001, 0 e o 0 0 007 °0 0°00°0 0° 1°°0 0°°e 0 °0®® °0 0°0°°°°°0°0°0°0°°°1 0° 0 0 0 0 0 0 0 0 0000000A0 0 6.5" oo A°oe0000e000ee0000e o0 0 0 0 0 0 0 o A ° s.so 00 os do 00 °® 0 OI 000010A1 0 AOOpe polo °® (166 mm) °o °°0°e°a°A°a°0°e°e°e o° 11 ss,1° °o°c o°o°o°° a°o°o°o ® °0 I o° °0°0 010°0°0°0°0 °e°o°e°e o° °o°o o°a°o°o°o°o °o°o°o om® °0 0°0°I°e°o°0°e°I°0°0 0° °0°0 0°p°o°o°0°0°0°0°0°0°0 0°0° °°0® 0o a0o0o0a0000$e0o0A0o 0o 0000 000000000000000000000 p0 OOo0o0000°000°000000000000 0"0000000 Op 00 1 0°0°0°0°0°0°0°0°0°0 80 o°0°0° °° °° °•°0°0°0 °° a�°20°°�0�0�°°0�°�a °0 °0° °000 °°0°0o°a°0.o°° 0 0 001.0. A0555-01 fl A0648-00 Wall-Mount Speaker Wall-Mount Speaker Strobe 2.33 6 [1%2] [41.61 fig"dla. 1.0" 1.63" (113 mm) (2fiA mm)) (41A mm) I Ceiling-Mount Speaker AO—_ Ceiling-Mount Speaker Strobe Ao__ L-Series with LED: Surface Mount Back Box ° ° t A0649-00 A0650-00 Wall-Mount Speaker Strobe with Ceiling-Mount Speaker Strobe with SBBSPSRUSBBSPWL Surface Mount Back Box SBBCRUSBCWL Surface Mount Back Box AVDS-62174:A a 08/29/2024 a Page 3 L-Series with LED: Ordering Information Model Description L-Series with LED Speaker Strobes SPSCRLED 2-WIRE,SPEAKER STROBE LED RED CEILING SPSCRLED-B 2-WIRE,SPEAKER STROBE LED RED CEILING BILINGUAL SPSCRLED-BT 2-WIRE,SPEAKER STROBE LED RED CEILING BILINGUAL WITH TRIM SPSCWLED I 2-WIRE,SPEAKER STROBE LED WHITE CEILING SPSCWLED-B 2-WIRE,SPEAKER STROBE LED WHITE CEILING BILINGUAL SPSCWLED-BT 2-WIRE,SPEAKER STROBE LED WHITE CEILING BILINGUAL WITH TRIM SPSCWLED-T 2-WIRE,SPEAKER STROBE LED WHITE CEILING WITH TRIM SPSCWLED-TP 2-WIRE,SPEAKER STROBE LED WHITE CEILING PLAIN WITH TRIM SPSCWLED-CLR-ALERT 2-WIRE,SPEAKER STROBE LED WHITE CEILING ALERT CLEAR LENS SPSCWLED-P 2-WIRE,SPEAKER STROBE LED WHITE CEILING PLAIN SPSCWLED-SP 2-WIRE,SPEAKER STROBE LED WHITE CEILING FUEGO SPSRLED 2-WIRE,SPEAKER STROBE LED RED WALL SPSRLED-B 2-WIRE,SPEAKER STROBE LED RED WALL BILINGUAL SPSRLED-P 2-WIRE,SPEAKER STROBE LED RED WALL PLAIN SPSRLED-SP 2-WIRE,SPEAKER STROBE LED RED WALL FUEGO SPSWLED I 2-WIRE,SPEAKER STROBE LED WHITE WALL SPSWLED-B 2-WIRE,SPEAKER STROBE LED WHITE WALL BILINGUAL SPSWLED-ALERT 2-WIRE,SPEAKER STROBE LED WHITE WALL ALERT AMBER LENS SPSWLED-CLR-ALERT 2-WIRE,SPEAKER STROBE LED WHITE WALL ALERT CLEAR LENS SPSWLED-P 2-WIRE,SPEAKER STROBE LED WHITE WALL PLAIN L-Series Speaker Description SPCRL 2-WIRE,SPEAKER RED CEILING SPCWL 2-WIRE,SPEAKER WHITE CEILING SPRL 2-WIRE,SPEAKER RED WALL SPWL I 2-WIRE,SPEAKER WHITE WALL Accessories Description SBBSPWL BACK BOX,WALL,SPEAKER,RED SBBSPWL BACK BOX,WALL,SPEAKER,WHITE SBBCWL BACK BOX,CEILING,SPEAKER,RED SBBCWL BACK BOX,CEILING,SPEAKER,WHITE TR-2 TRIM RING,WALL,RED TR-2W TRIM RING,WALL,WHITE TRC-2 TRIM RING,CEILING,RED TRC-2W TRIM RING,CEILING,WHITE LED Lenses Description LENS-A3 Lens LED Amber Wall/Ceiling LENS-133 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Bezels Description BZSPR WALL RED BEZEL KIT BZSPW WALL WHITE BEZEL KIT BZSPWC CEILING RED BEZEL KIT BZSPWC CEILING WHITE BEZEL KIT Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL(ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP(FUEGO), -SPE(FUEGO/FIRE) Bezels for use only with Speaker Strobes 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. �^ www.systemsensor.com 1 ©2024 System Sensor. STEM 3333 Unity Drive, Mississauga,ON 1-51-3S6 Canada Product specifications subject to change without notice.visit systemsensoccom SENSORS or current product information,including the latest version of this data sheet. Phone:800-SENSOR2•Fax:905-812-0771 AVDS-62174:A•OS/29/2024 www.systemsensor.ca SYSTEM SENSOR° IIIIII i�i�i�i�i�i�i�i�i• L Series Outdoor �IIIIIIIIIIFfllllllllllll Speakers and L-Series with LED Outdoor Speaker F I R E Strobes P System Sensor L-Series and L-Series with LED audible == visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series Outdoor Speakers and • LED technology provides lower current draw L-Series with LED Outdoor Speaker Strobes offer the most • Weatherproof per NEMA 4X, IP56 as a standalone device versatile and easy-to-use line of weatherproof speakers and speaker • Rated from-40°F to 151°F strobes that can meet virtually any application requirement, including • Electrically compatible with legacy SpectrAlert,SpectrAlert indoor, outdoor, wet, dry, and washdown environment applications Advance and L-series devices at 16-33 VDC in temperatures from —40oF to 151°F. The speakers provide a broad • Field-selectable candela settings on wall units: 15,30,75,95, frequency response range, low harmonic distortion offering a high- 110, 135,and 185 fidelity sound output while offering a high-volume sound output for use • Field-selectable candela settings on ceiling units: 15,30,75, in high ambient noise applications. 95, 115, 150,and 177 The L-Series Outdoor and L-Series with LED Outdoor appliances • Rotary switches for candela,speaker voltage(25 and 70.7 are NEMA 4X and IP56 rated without having to seal the back box. Vrms)and power settings(1/4,1/2, 1,and 2 watts) Additional caulk or sealant are not required on the back box for a faster, • Mounting plates with wirenuts are provided to make the cleaner installation. The L-Series platform offers a modern aesthetic connection between the field wiring and the mounting plates across the indoor and outdoor platform and design variations across • Synchronization through use of UL approved power supplies applications: wall or ceiling mount, red or white color choices, LED that support System Sensor Sync protocol or System Sensor colored lenses for distinctive visual signaling. In addition, installers MDL Sync Module can easily adjust appliances through rotary switches for candela, • Tamper-resistant construction speaker voltage and power settings. • Speakers and Speaker strobes listed for wall or ceiling use Speakers offer high fidelity and high volume sound output LED technology offers significantly lower current draw compared to • older Xenon bulbs across a full candela range.This improves design flexibility for notification appliance circuits(NACs)while also reducing power supply requirements allowing for simpler and lower cost installations. UL listed waterproof wirenuts are provided to make the connection between the field wiring and the mounting plates. Agency Listings The outdoor devices ship with plastic back boxes that accommodate in-and-out wiring for daisy chaining devices. Knock-outs located on SIGNALING SIGNALING � the back eliminate the need to drill holes for screw-in mounting. c&us c& F M : LISTED LISTED APPROVED Note: When replacing SpectrAlert Advance products, the backbox Speaker-Strobes: Speakers. 3057493 7125-1653:0538 must be updated to the L-Series with LED backbox. 54048 S4048 3057493 7125-1653:05389 p AVDS-62185-00•03/17/2025•Page 1 Product Specifications Physical/Electrical Specifications Standard Operating Temperature -40°F to 151 °F(-40°C to 66°C)) Humidity Range 0 to 95 5% Power 1/4,1/2, 1,2 Watts Frequency Range 400 to 4000 Hz Maximum Supervisory Voltage(Speakers) 50 VDC Maximum Supervisory Voltage(Strobe) 33 VDC Strobe Flash Rate 1 Flash Per Second Nominal Voltages,Speakers 25 Volts or 70.7 Volts(nominal) Nominal Voltage,Strobe Regulated 24 VDC Operating Voltage Range,Strobe 16 to 33 VDC Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wall Speaker Strobes(including lens) 6.69" L x 5.16" W x 2.47 D (170mm L x 131 mm W x 63mm D) Wall Speaker Strobes(including lens)with SBBSPRUWL Surface 6.69" L x 5.16" W x 4.72" D (170mm L x 131 mm W x 120mm D) Mount Back Box Ceiling Speaker Strobes(including lens) 6.97"diameter x 2.23"D(177mm x 57mm) Ceiling Speaker Strobes(including lens)with SBBCRUWL Surface 6.97"diameter x 4.73"D(177mm x 127mm) Mount Back Box Wall Speakers 6.69"L x 5.16"W x 1.72"D(170mm L x 131 mm W x 44mm D) Wall Speakers with SBBSPRUWL Surface Mount Back Box 6.69"L x 5.16"W x 3.97"D(1700mm L x 131 mm W x 101 mm D) Ceiling Speakers 6.97"diameter x 1.2"D(177mm x 31 mm) Ceiling Speakers with SBBCRUWL Surface Mount Back Box 6.97"L diameter x 3.97"D(177mm x 101 mm) NOTE:SBBSPRL/WL Surface Mount Back Box intended for speaker strobes and speakers. OutputMinimum Speaker Strobe Sound 1/4W 1/2W 1 W 2W UL Reverberant(dBA @10 ft) 77 81 83 85 UL Anechoic(dBA @10 ft) 77 81 83 85 Minimum Speaker Only Output 1/4 W 1/2 W 1 W 2 W UL Reverberant(dBA @10 ft) 77 81 83 85 UL Anechoic(dBA @10 ft) 77 81 83 85 UL/ ULC Current Draw Candela 16-33 Volts Rating Wall Ceiling Candela 15 18 18 Range 30 22 22 75 70 70 95 75 75 110 85 — 115 — 90 135 105 — 150 — 110 177 — 115 185 120 — AVDS-62185-00•03/17/2025•Page 2 L-Series Dimensions 3.971 [100,86] - 4.128 - 2.250 �[57,15] 000 0 0 0 0 000 00 00000000000Q0000Q00 0®0 Qpp� pa 0000 00 a "0 00000000000000000 og ® a 1 O 00000pA0000000000 00 O ® 7 6.701 0® 0�0�0000000�00 ®010 [170,221 00 00000000000000000 00 0oL R g�0 o0�0��0s�100 ° 000 0000�0 000�00 0 0 0 0 000 0 0000o 0 00 O 0 Outdoor Wall Speaker with Surface Mount Back Box(SBBSPRU SBBSPWL) 3.965 [100,711 06.967 2.500 [176,971 [63,5] OUBU b�0g o "$8$Pooh ��A 0oo0/�00 m pWoo ovo U Outdoor Ceiling Speaker with Surface Mount Back Box (SBBCRUSBBCWL) 4.722 [119,951 4.131 4.128 [104,931 �2.250 [57,151 ® 1PP„g,er O e'O' D e e e0e 0 ®®000 00000o0000®1 0 00 000 80 0 00 0 p B 6.699 �00 °00 O0 ® 00 [170.151 0®00 A ® 00 00 000B00A000A"®0000 00 0 9 , 0®OBB 0 0 00 00000000NR 000000 00 00 00 000000 ® p0 BO 000 00 0000 000 0 000 00 0 p� Outdoor Wall Speaker Strobes with Surface Mount Back Box(SBBSPRUSBBSPWL) AVDS-62185-00.03/17/2025•Page 3 4.987 1126,681 4.394 [111,621 6-969 2 500 [[1177,0111 [63,51 0 O ® " Outdoor Ceiling Speaker Strobes with Surface Mount Back Box(SBBCRUSBBCWL) L-Series with LED: Ordering Information DescriptionModel L-Series with LED Outdoor Speaker Strobes SPSRKLED Outdoor Speaker Strobe,Wall,Red SPSRKLED-P Outdoor Speaker Strobe,Wall,Red,Plain SPSRKLED-B Outdoor Speaker Strobe,Wall,Red,Bilingual SPSWKLED I Outdoor Speaker Strobe,Wall,White SPSWKLED-P Outdoor Speaker Strobe,Wall,White,Plain SPSWKLED-B Outdoor Speaker Strobe,Wall,White,Bilingual SPSWKLED-CLR-ALERT Outdoor Speaker Strobe,Wall,White,Alert,Clear lens SPSCWKLED Outdoor Speaker Strobe,Ceiling,White SPSCWKLED-P Outdoor Speaker Strobe,Ceiling,White,Plain SPSCWKLED-B Outdoor Speaker Strobe,Ceiling,White,Bilingual SPSCWKLED-CLR-ALRT Outdoor Speaker Strobe,Ceiling,White,Alert,Clear lens L-Series Outdoor Speakers SPWKL Outdoor Speaker,Wall,Red,Plain SPWKL Outdoor Speaker,Wall,White,Plain SPCWKL Outdoor Speaker,Ceiling,White,Plain Accessories SBBSPWL Back Box,Wall,Speaker,Red SBBSPWL Back Box,Wall,Speaker,White SBBCWL Back Box,Ceiling,Speaker,Red SBBCWL Back Box,Ceiling,Speaker,White LED Lenses LENS-A3 Lens LED Amber Wall/Ceiling LENS-133 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Notes for L-Series with LED Outdoor Speaker Strobes: • All-P models have a plain housing(no"FIRE"marking on cover.) • All-ALERT models have"ALERT'marking on cover. • All-B models have"FIRE/FEU"marking on cover. 3825 Ohio Avenue•St.Charles, IL 60174 USA Phone:800-SENSOR2•Fax:630-377-6495 System Sensor®is a registered trademark www.systemsensor.com of Honeywell International,Inc. �^ 3333 Unity Drive,Mississauga,ON L5L 3S6 Canada 1 SYSTEM Phone:800-SENSOR2•Fax:905-812-0771 ©2025ewi Sensor Product specifications subject to changange without notice.Visit systemsensor.com SENSOR® www.systemsensor.ca for current product information,including the latest version of this data sheet. AVDS-62185-00.03/17/2025 SYSTEM SENSOR SMOKE Duct Smoke - Detector Accessories • I Expand the versatility of the InnovairFlexrM line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick,convenient inspections at eye level and effective audible and visible notification options.All MHR Mini-Horn, Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn,White The APA151 piezo annunciator,which replaces the APA451 with a RA100Z/RA100ZA Remote Annunciator new,improved look, provides an audible alarm signal,a red LED to RTS151 Remote Test Station indicate alarm status,and a green LED to indicate power status. It is RTS151 KEY Remote Test Station with Key intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel,to comply with RTS2 Multi-Signaling Accessory NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlert®Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications.Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location.For 4-wire detectors,the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors,the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors.These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset,or both Agency Listings by a push button switch.They also enable sensitivity measurements using the SENS-RDR sensitivity reader(sold separately).The AOS &U O; (Add-On Strobe)is an optional accessory included with the RTS2- F M AOS model. LISTED APPROVED 7300-1653:0212 C C 7300-1653:0211 S2522 3034401 7135-1653:0196 9080301 Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator RTS1 51 Remote Test Station Voltage Regulated 24 VDC Power Requirements Alarm LED:2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0°C to 49°C(32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60oC(14°F to 140°F) Dimensions 4.6"H x 2.9"W x.45"D Relative Humidity 95%non-condensing SpectrAlertO Advance Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR(Full Wave Dimensions 4.8-H x 2.90-W x 1.4-D Rectified)or Regulated 24 VDC or FWR RTS1 51 KEY Remote Test Station with Key Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Power Requirements Power LED(Green): 14 to 35 VDC, 29 mA RMS max.at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 VDC, Humidity Range 10 to 93%non-condensing 12 mA max. Nominal Sounder 3 kHz Total Current: 105 mA max. Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60oC(14°F to 140°F) Dimensions 4.6-H x 2.9-W x 0.45-D Relative Humidity 95%non-condensing Remote Annunciator Wire Gauge 14 to 18 AWG Voltage Range Conventional System:3.1 to 32 VDC Dimensions 4.6-H x 2.75-W x 1.8-D Intelligent System: 18 to 32 VDC RTS2 and RTS2-AOS Multi-signaling Accessory Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6-H x 2.8"W x 1.3"D Power Requirements Standby:3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe:30 mA max. Alarm with strobe:55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60oC(14°F to 140°F) Relative Humidity 95%non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8-W x 5.3-H x 1.6-D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. sMoxE RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AIDS fSYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. 1 Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensorcom w SOR' for current product information,including the latest version of this data sheet. SENSOR' www.systemsensor.com HVDS20202•8/13 SYSTEA4 Alarm Bells a SEI Va SOR 40 • Model Q' SSM12/24-X SSV120-X _ SSL24-6 Alarm Bells General Description System Sensor's SSM/SSV Series and SSL24-6 Alarm Bells are low current,high decibel notification appliances for use in fire and burglary systems or other signaling applications. The Alarm Bells provide loud resonant tones. The SSM series (SSL24-6)operates on 12/24VDC (24VDC)and are motor driven,while the SSV series operates on 120VAC utilizing a vibrating mechanism. The alarm bell is polarized for use with supervision circuitry and have under dome strikers &operating mechanisms. The diameter of the product shall be no smaller than nominal 6" (152mm). The bells can make large resonant sound. Features • Approved for indoor and outdoor use • Available in six-inch, eight-inch, and ten-inch sizes • Low current draw • AC and DC models • High dB output • Reliable performance and simplified installation. Specifications SSM Series SSV Series Nominal Voltage 12VDC 24VDC 120VAC 24VDC Operating Voltage 9-13.2VDC 16-33VDC 96-132VAC 16"30VDC Alarm Current <40mA <27mA <53mA <30mA Voice Output(3m) 80/81/82dB 82/85dB 80-105dB Operating Temperature Range -35°C-60°C -35°C-66°C -35°C-66°C -10°C-55°C Boundary Dimension 6" . 8" . 10" 6" Installation Diagram rrr� r � L , OGITEO TO t �0 ��FTANDAM rAWME OUTLET BOX �laAMf iTIBMFR LOCATED ON p=110 OF DELL VORB MOM REM) �ltl�B BASIC MECHANISM AND GONGS SURFACE INSTALLATION REJ BIALI[ NWE CIAIF TO NEX'"L'I ERON oANEL OR TERMINAL REp.TENCE SSM24-X SERIES BELL WIRE CONNECTION(BACK VIEW) Ordering Information Product Model Ordering Model Product Description CCCF UL FM UOM SSM12-6 SSM12-6 Bell,6" ,12VDC,metal V V V EA SSM12-8 SSM12-8 Bell,8" ,12VDC,metal V V V EA SSM12-10 SSM12-10 Bell,10" ,12VDC,metal V V V EA SSM24-6 Bell,6" ,24VDC,metal V V V EA SSM24-6 Bell,6" ,24VDC,marked with "Fire Alarm" and SSM24-6-HK in white color,metal EA SSM24-8 Bell,8" ,24VDC,metal V V V EA SSM24-8 Bell,8" ,24VDC,marked with "Fire Alarm" and SSM24-8-HK in white color,metal EA SSM24-10 Bell,10" ,24VDC,metal V V V EA SSM24-10 Bell,10" ,24VDC,marked with "Fire Alarm" and"k " SSM24-10-HK in white color,metal EA SSV120-6 SSV120-6 Bell,6" ,120VAC,metal V V V EA SSV120-8 SSV120-8 Bell,8" ,120VAC,metal V V V EA SSV120-10 SSV120-10 Bell,10" ,120VAC,metal V V V EA SSL24-6 SSL24-6 Bell,6" ,24VDC,aluminum V EA SENSOR' System Sensor Headquarters System Sensor China System Sensor Canada System Sensor Italy System Sensor Far East Ltd System Sensor India 3825 Ohio Avenue 28 Tuan Jie South Road, Ph:905-812-0767 Ph:39 040 949 0111 Ph:852 21919003 Ph:91 124 2371770-270 St.Charles,IL 60174 Hi-Tech Development Zone Fx:905-812-0771 Fx:39 040 382 137 Fx:852 27366580 Fx:91 124 2373118 Ph:630-377-6580 Xi'an,710075,China Fx:630-377-6495 Ph:+86 29 85387800 System Sensor Europe System Sensor Mexico System Sensor Singapore System Sensor Australia Free Phone:800-736-7672 Fx:+86 29 88895930 Ph:44(0)1527 406700 Ph:54 11 4324-1909 Ph:65 6273 2230 Ph:61-3-5428 1142 Web:www.systemsensor.com Web:www.systemsensor.com.cn Fx:44(0)1527 406699 Fx:54 11 4324-5999 Fx:61-3-5428 1172 Copyright by Van System Sensor Electronics LTD. 4Wo,, __q"00 M S E R I ES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire HWF2A-COM alarm control panel) with a built-in dialer. Models include: „o HWF2A-COM(AT&T LTE&IP) HWF2V-COM(Verizon LTE&IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter(DACT). Three selectable reporting paths include:LTE cellular only,IP only,or IP primarywith LTE cellular backup.All signals from the HWF2-COM Series are delivered to the AlarmNet° network control centerwhich routes highly encrypted,cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station.The AlarmNet°network control center is fully redundant and monitored 24/7.Installation and programming are easy using the handheld 7720P Programming tool. HWF2V-COM �Ya FEATURES AND BENEFITS • LTE and IP connection tested every day connection(LAN or WAN),DSL model or • Diagnostic LEDs indicate signal strength • Three selectable reporting paths:LTE cable modem and status cellular only,IP only,or IP Primarywith LTE • Data transmits over standard Contact ID . Choice of LTE provider services cellular backup protocol but is secured with the industry's • QOS:Quality of Service diagnostics via • Requires no change to the existing FACP advanced encryption standard(AES 256 configuration bit) AlarmNet conveys vital communicator information including signal strength, • Connects directly to the primary and • Supports both dynamic(DHCP)or public message path used,and when the message secondary telephone ports of a DACT and private Static IP addressing was received • Plan choices range from 5 minute,60 • Reliable connection:IP and cellular 7720P Handheld programmer for easy minute,6 hour,and 24 hour supervision connection tested every day setup intervals • Built-in,standalone power supply module. • Operates overthe following communication Onboard charging circuit design protocols:LTE,HSPA+(4G)HSPA(3G) accommodates battery backup.Includes • Works over any type of customer provided primary power and battery supervision Ethernet 10/100 based network Honeywell The HWF2-COM LTE/IP fire communicators operate over the most • Primary Subscriber ID(four digits),obtained from your monitoring modern and common cellular networks including LTE,4G and3G. station • Communication Module MAC ID,and MAC CRC number located on They connect to any customer provided Ethernet 10/100 base the outside of the box and inside of the module network connection(LAN or WAN),DSL or cable modem.Selectable All parameters are assigned by the monitoring station. reporting path feature allows the radios to be configured for a single or dual path,while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements.Selectable paths and supervision AlarmNet communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals.The network ELECTABLE r:: PTION 'I SUPERVISI provides extensive coverage in the United States and Canada.The PATH TIMES AlarmNet Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure 2010 Cell Single path,cellular 5 Minutes support.Redundant hardware servers,real-time backup databases, 2010 IP Single path,IP 5 Minutes and generators with battery backup at all locations ensure 2010 IP&Cell Dual path,IP and cellular 24 Hours continuity of service.Signals from AlarmNet are transmitted to 2013 Cell Single path,cellular 60 Minutes central station receivers using multiple communication paths 2013 IP Single path,IP 60 Minutes consisting of the Internet,LTE radio network,or toll free plain old telephone service(POTS).Visit AlarmNet.com to learn more. 2013 IP&Cell Dual path,IP and cellular 6 Hours INSTALLATION REQUIREMENTS,UL COMPLIANCE OPERATION To meet UL864/NFPA requirements,ensure the following: When an event occurs,the FACP goes off-hook to dial the central HWF2-COM Series must be installed in accordancewith the National station.The HWF2-COM Series dialer capture module detects the off-hook condition and provides the fire panelwith a dialtone.When Fire Protection Association(NFPA)standards 70 and 72 the fire panel detects the dial tone,it begins dialing the central ' HWF2-COM Series must be mounted in the same room and within station. 20 feet of the fire panel. • HWF2-COM Series and all equipment used for the IP connection After the dialing is completed,the dialer capture module returns a (e.g.,router,hub,modem,etc)must be UL-listed,powered from an signal to the fire panel.The fire panel then sends the Contact ID unswitched branch circuit,and be provided with appropriate standby reports to the dialer capture module,which in turn sends a signal power. after the report is successfully received from the fire panel.The • HWF2-COM Series must use the 7AH battery(not included)to dialer capture nodule sends the Contact ID reports to the HWF2- provide 24 hour backup capability COM Series communications module.When allthe reports are sent, the fire panel goes on-hook.The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR/PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information.This is saved to the HWF2-COM communicator panel memory.When the HWF2-COM is installed at the site and connected to the Internet/ Intranet,it registers with the AlarmNet Receiver. For most installations,the only required parameters are: • Primary City ID(two digits),obtained from your monitoring station • Primary Central Station ID(two digits),obtained from your monitoring station Page 2 of 3—DH-62010:13•6/27/2019 HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Both models include: Transformer: • Red cabinet with key and lock AlarmNetO is a registered • Primary:120VAC,60Hz,0.5A • Wall outlet box trademarks of Honeywell • Secondary:l8VDC,50VA • Dialer capture module International Battery: • LTE communications module @2019 by • - International • One 12 V 7.0 AH lead-acid battery:(not • Antenna and mounting adapter Inc.All rights -• supplied) • PowerBoostl power supply Unauthorized use of document • Battery charging current:1 Amp maximum • LED display board is strictly prohibited. • Battery discharge current:Standby 230mA, • Transformer Active 950mA • Manual and required screws This document 't intended to be • Cables,etc. used for installationpurposes. CABINET SPECIFICATIONS try to keep our •• information - HARDWARE • Dimensions:14.875"H x 12.75"W x 3.0"D ANTENNA AND EXTERNALup-to-date" • accurate. • cover all specific (37.8cm H x 32.4cm W x 7.6cm D) applications • Color:Red CELL-ANT3DB:3dBA gain antenna anticipate all requirements.All WA7626-CA:SMA to N adapter cable specifications are subjectto change SHIPPING DIMENSIONS 7626-50HC:50 ft.antenna cable,low loss without notice. • Weight:5.3 lbs(6.94kg) • Dimensions:eight: .3lbs .625"H x 13.79"W x 9.25"D Note:The WA7626-CA adapter cable and • • • • ' (39.7cm H x 34.9cm W x 23.9cm D) 7626-50HC antenna cable are only required when installing the CELL-ANT3DB TEMPERATURE AND HUMIDITY antenna remotely. RANGES OTHER ACCESSORIES This system meets NFPA requirements for operation at 0-49°C/32-1201F and at a 7720P:HWF2V-COM,HWF2A-COM and relative humidity 93%+-2%RH(non- IPGSM-4G handheld programmer condensing at 32°C+-21C(901F+-31F). HPTCOVER:Plug-in transformer box for However the useful life of the system's HWF2V-COM,HWF2A-COM,and IPGSM- standby batteries and the electronic 4G communicators components may be adversely affected by BAT-1270:Battery 12 Volts,7AH,sealed extreme temperature ranges and humidity. AGENCY LISTINGS AND Therefore,it is recommended that this APPROVALS system and its peripherals be installed in an environment with a normal room The listings and approvals below applyto temperature of 15-271C/60-801F. the HWF2-COM Series communicators.In some cases,certain modules may not be PRODUCT LINE INFORMATION listed bycertain approval agencies,or listing HWF2V-COM: TE Digital Cellular Fire may be in process.Consult the factory for Alarm Communicator and Internet Panel, latest listings. Verizon LTE/I UL Listed:S789 HWF2A-COM:LTE Digital Cellular Fire CSFM:7300-1645:0511 Alarm Communicator and Internet Panel, FDNY:Approved AT&T LTE/I THE FUTURE Is Honeywell Power Products WHAT WE 12 Clintonville Road MAKE E IT Northford,CT 06472-1610 203.484.7161 DH-62010 I e 1 06/19 www.honeywellpower.com ©2019 Honeywell International Inc. Honeywell ll PS SERIES RECHARGEABLE SEALED LEAD ACID BATTERIES ,. Fire& Security OWN AW General C" • ' — Purpose II T _ . , _ .... .. Emer ency Battery Lighting 0 ,r► - �oMODEL 74 Pb PoW::;SP="i,5o •-•` Medical Power Sonic's PS series of sealed lead acid batteries have been designed with AGM (Absorbent Glass Mat) technology to ensure superior performance and reliability. They have been engineered specifically for use in general purpose float and light cyclic applications including security and fire protection systems,emergency lighting,UPS, toys and medical devices. POWERA 50N1C TRUSTED BATTERY SOLUTIONS power-sonic.com BATTERYPOWERP.SSONIC7. TRUSTED • • AV WEF?�; 50NG 50 B Fire& General Inner Medical ggricy Security Purpose Li ing rMOOEL �pWER �50N%C ppkyEa ea!� "• MOO EL P513d508 � �_. FEATURES PS SERIES • General purpose VRLA battery • Absorbent Glass Mat(AGM)technology for superior Rechargeable Sealed Lead Acid Batteries performance • Power and volume ratio yielding unrivalled energy density • VdS approved models • Valve regulated,maintenance free spill proof construction • Rugged impact resistant ABS case and cover flame by o NCP Certificatie retardant to UL94:HB and UL94:V0 VdS • Low discharge rate for long shelf life SPECIFICATIONS i' Dimensions: Nominal 'Oat service Weight Terminal Model Voltage 68-F(20-C) 20-hr 10-hr 5-hr 1-hr Length Width Height Total Height Type Years 1.80111 1.80V/cell 1.75V/cell 1.60V/cell inch mm inch mm inch mm inch mm His. kgs. PS-260 2 5 6.0 5.4 4.9 3.6 1.97 50 1.34 34 3.94 100 4.13 105 0.89 0.4 F1 PS-435ST 4 5 3.5 3.3 2.9 2.1 3.54 90 1.34 34 2.32 59 2.56 65 0.99 0.45 F1 PS-445 4 5 4.5 4.2 3.8 2.7 1.89 48 2.09 53 3.70 94 3.86 98 1.3 0.59 F2 PS-490 4 10-12 8.0 7.9 7.7 6.1 4.02 102 1.73 44 3.74 95 3.98 101 2.2 1 F2 PS-4100 4 5 10.0 9.3 8.5 6.2 4.01 102 1.97 50 3.70 94 3.85 98 2.5 1.13 F1 PS-610 6 5 1.0 0.9 0.8 0.6 2.00 51 1.65 42 2.00 51 2.20 56 0.55 0.25 F1 PS-612 6 5 1.2 1.1 1.0 0.7 3.82 97 0.94 24 2.00 51 2.20 56 0.64 0.29 F1 PS-612ST 6 5 1.2 1.1 1.0 0.7 3.82 97 0.94 24 2.00 51 2.20 56 0.64 0.29 F1 PS-621 6 5 2.0 1.9 1.7 1.2 1.69 43 1.46 37 2.99 76 2.99 76 0.75 0.34 F1 PS-628 6 5 2.9 2.6 2.5 1.8 2.60 66 1.30 33 3.86 98 4.06 103 1.3 0.59 F1 PS-630 6 5 3.5 3.3 3.0 2.2 5.28 134 1.34 34 2.35 60 2.56 65 1.37 0.62 F1 PS-630ST 6 5 3.5 3.3 3.0 2.2 5.28 134 1.34 34 2.35 60 2.56 65 1.37 0.62 F1 PS-632 6 5 3.5 3.3 3.0 2.2 2.60 66 1.30 33 4.65 118 4.80 122 1.57 0.71 F1 PS-640 6 5 4.5 4.1 3.3 2.8 2.76 70 1.86 47 3.94 100 4.25 108 1.79 0.81 F1 PS-650LF&LS 6 5 5.0 4.3 4.0 3.0 2.64 67 2.64 67 3.94 100 4.64 118 1.8 0.82 F1/SP PS-665 6 5 6.5 6.1 5.5 4.0 3.86 98 2.20 56 3.78 96 4.02 102 2.7 1.22 FP PS-670 6 5 7.0 6.3 6.0 4.3 5.95 151 1.34 34 3.70 94 3.94 100 2.42 1.1 F1 PS-682 6 5 8.5 7.9 7.3 5.3 3.86 98 2.20 56 4.65 118 4.72 120 3.35 1.52 F1 PS-6100 6 5 12.0 11.5 10.5 7.3 5.95 151 2.00 51 3.70 94 3.86 98 4.3 1.95 F1/F2 PS-6120 6 10-12 11.0 10.9 10.6 7.9 5.95 151 2.00 51 3.70 94 3.94 100 4.3 1.95 F1 PS-6120 FR 6 10-12 11.0 10.9 10.6 7.9 5.95 151 2.00 51 3.70 94 3.94 100 4.3 1.95 F1 PS-6120FP 6 5 13.0 12.2 11.1 8.0 4.25 108 2.80 71 5.55 141 5.55 141 4.8 2.18 FP PS-6200 6 5 20.0 18.6 17.0 12.4 6.18 157 3.27 83 4.92 125 4.92 125 7.1 3.22 N61 GLOBAL HEADQUARTERS POWER-SONIC EMEA FURTHER INFORMATION (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICA) Power-Sonic Corporation Smitspol 4,3861 IRS Nijkerk, Please refer to our website www.power-sonic.com 365 Cabela Dr Suite 300, The Netherlands for a complete range of useful downloads,such as Reno,Nevada 89439 T NIL: +31 33 7410 700 product catalogs,material safety data sheets USA T UK:+44 1268 560 686 T: +1 775 824 6500 T FIR: +33 344 32 18 17 (MSDS), ISO certification,etc. E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. ©2018.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. , • • • All data subject to change without notice.E&O.E POWERP / TRUSTED BATTERY SOLUTIONS ppWER SON/C Fire& General Em Medical Security Purpose Li�rfin"g'y Arns'Ep_. PpyyEl7 50N1C --- PS SERIES Rechargeable Sealed Lead Acid Batteries (continued) Dimensions:SPECIFICATIONS (continued) -.Limnite in Rated Capacity(AH) Approx. ModellwHominal float service Terminal 10-hr 5-hr 1-hr Length Width Height Total Height Weight Type Years 11.801f/cell 11.80V/cell 1.75V/cell 1.60V/cell inch mm inch mm inch mm inch mm His. kgs. PS-6360 6 5 36.0 33.5 30.6 22.3 6.25 159 3.35 85 6.50 165 6.93 176 12.1 5.49 F2/NB1 PS-6580 6 5 58.0 56.0 50.0 35.0 7.28 185 4.41 112 8.07 205 8.07 205 19.5 8.8 F2 PS-62000 6 5 210.0 200.0 180.0 134.0 12.05 306 6.65 169 8.65 220 8.96 228 63.9 29 T8 PS-832 8 5 3.2 3.0 2.7 2.0 5.29 134 1.44 36.5 2.49 63 2.70 69 1.65 0.75 F1 PS-1208JST FIR 12 5 0.8 0.7 0.7 0.5 3.78 96 0.98 25 2.44 62 2.44 62 0.77 0.35 JST PS-1208WL 12 5 0.8 0.7 0.7 0.5 3.78 96 0.98 25 2.44 62 2.44 62 0.77 0.35 WL PS-1212 12 5 1.4 1.3 1.2 0.8 3.78 96 1.69 43 2.04 52 2.28 58 1.2 0.54 F1 PS-1221SL 12 5 2.0 1.9 1.7 1.2 5.91 150 0.80 20 3.52 89 3.52 89 1.5 0.68 F1/0 PS-1223 12 5 2.3 2.3 2.0 1.4 7.17 182 0.94 24 2.40 61 2.40 61 1.7 0.77 PC PS-1220 12 5 2.5 2.2 2.0 1.5 7.00 178 1.38 35 2.36 60 2.56 65 2.1 0.95 F1 PS-1228 12 5 2.8 2.5 2.4 1.7 5.24 133 1.30 33 3.82 97 4.09 104 2.6 1.18 F1 PS-1227 12 5 2.9 2.6 2.5 1.8 3.11 79 2.20 56 3.90 99 4.13 105 2.4 1.09 F1 PS-1229L 12 5 2.9 2.7 2.5 1.8 7.00 178 1.38 35 2.36 60 2.60 66 2.3 1.04 F1 PS-1230 12 5 3.4 3.3 2.9 2.2 5.24 133 2.64 67 2.36 60 2.60 66 2.9 1.32 F1 PS-1238 12 5 3.8 3.5 3.2 2.4 7.68 195 1.85 47 2.91 74 2.99 76 3.5 1.59 F1 PS-1242 12 5 4.5 4.2 3.8 2.7 3.54 90 2.76 70 3.98 101 4.21 107 3.26 1.48 F1 12 5 5.0 4.6 4.2 2.9 3.54 90 2.76 70 3.98 101 4.21 107 3.0 1.39 F1 F2 PS-1270 12 5 7.0 6.5 6.0 4.5 5.94 151 2.56 65 3.70 94 3.86 98 4.8 2.18 F1/F2 PS-1280 12 5 8.0 7.2 6.7 4.9 5.94 151 2.56 65 3.72 94.5 3.90 99 5.6 2.54 F1/F2 PS-1282L 12 5 9.0 8.1 7.7 5.6 7.72 196 2.20 56 4.65 118 4.65 118 6.9 3.13 F1 PS-1282SH 12 5 9.0 8.1 7.7 5.6 3.86 98 4.40 112 4.65 118 4.65 118 6.90 3.13 F1 PS-1290 12 5 9.0 8.1 7.2 5.4 5.94 151 2.56 65 3.70 94 3.86 98 6.00 2.72 F2/NB1 PS-12100H 12 5 10.5 10.0 9.4 6.8 5.94 151 2.56 65 4.40 112 4.67 118 7.23 3.28 F2 PS-12100 12 5 12.0 11.5 10.0 9.0 5.94 151 4.00 102 3.70 94 3.86 98 8.14 3.69 F1/F2 PS-12120L 12 5 12.0 11.9 11.1 8.0 8.52 216 2.75 70 5.75 146 5.75 146 8.80 3.99 FP PS-12120 12 5 12.0 11.4 10.2 8.8 5.94 151 3.86 98 3.66 93 3.86 98 8.10 3.68 F2/NB1 PS-12140 12 5 14.0 13.0 12.5 8.5 5.94 151 3.86 98 3.70 94 3.94 100 9.25 4.2 F2 PS-12180 12 5 18.0 17.1 15.3 11.5 7.13 181 3.00 76 6.57 167 6.57 167 12.32 5.6 F2/NB2/T12 PS-12180 FR 12 5 18.0 17.1 15.3 11.5 7.13 181 3.00 76 6.57 167 6.57 167 12.32 5.6 F2/NB2/T12 PS-12200 12 5 20.0 19.0 17.0 13.1 7.13 181 3.00 76 6.57 167 6.57 167 13.09 5.95 T12 PS-12260 12 5 26.0 24.7 22.1 15.8 6.56 167 6.97 177 4.92 125 4.92 125 17.50 8.0 F2/NB2/T12 12 5 28.0 26.0 23.8 17.6 6.50 165 4.92 125 6.89 175 6.89 175 20.95 9.5 N131 PS-12330 12 5 33.0 30.0 26.2 19.1 7.72 196 5.14 131 6.22 158 7.00 176 23.00 10.5 N133 PS-12350 12 5 35.0 33.0 28.1 20.7 7.68 195 5.12 130 6.46 164 7.01 178 23.15 10.5 N133/T6 PS-12400 12 5 40.0 38.0 33.5 24.0 7.76 197 6.50 165 6.69 170 6.69 170 29.10 13.2 N134 PS-12550 12 5 55.0 52.3 46.7 36.2 8.90 226 5.31 135 8.15 207 9.02 229 37.62 17.0 T6/U GLOBAL HEADQUARTERS POWER-SONIC EMEA FURTHER INFORMATION (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICA) Power-Sonic Corporation Smitspol 4,3861 IRS Nijkerk, Please refer to our website www.power-sonic.com 365 Cabala Dr Suite 300, The Netherlands for a complete range of useful downloads,such as Reno,Nevada89439 TNL: +31 33 7410 700 product catalogs, material safety data sheets USA T UK:+44 1268 560 686 T: +1 775 824 6500 TFR: +33 344 32 18 17 (MSDS), ISO certification,etc. E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always referto the latest edition of our Technical Manual,as published on our website. ©2018.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. F!, •wer sonic • All data subject to change without notice.E&O.E memo," / / D BATTERY SOLUTIONSFire& General Inner incy Medical PO yyER SONIC ghrSecurity Purpose Li rig �q,YEF j50 R�SONIC ® - ^._ -�- - PS SERIES Rechargeable Sealed Lead Acid Batteries MONO (continued) SPECIFICATIONS Dimensions:Design Lite in Rated Capacity(AN) Approx. ominal float service Terminal Voltage 68'F(20'C) 20-hr 10-hr 5-hr 1-hr Length Width Height Total Height Weight Type Years .I1.80V/cell 1.75V/cell 1.60V/cell inch min inch mm inch mm inch mm His. kgs. PS-12750 12 10-12 78.6 75.0 63.8 45.0 10.25 260 6.69 170 7.95 202 8.74 222 53.24 24.2 T6/U PS-121000 12 10-12 100.0 95.2 83.0 57.9 12.05 306 6.61 168 8.19 208 9.06 230 67.50 30.6 T6/U PS-121000 FR 12 10-12 100.0 95.2 83.0 57.9 12.05 306 6.61 168 8.19 208 9.06 230 67.50 30.6 T6/U PS-121100 12 10-12 107.0 100.0 94.5 78.0 13.00 330 6.81 173 8.35 212 8.66 220 70.56 32.0 T11 PS-122500 12 5 260.0 250.0 215.4 152.5 20.55 522 10.55 268 8.66 220 8.90 226 161.00 73 T11 A number of our PS range of batteries are VdS approved. VdS is one of the world's leading inspection and udS certification companies in the fire protection and security industry.They set international standards with the publication of a comprehensive set of rules and guidelines for fire protection and safety equipment. VdS is one of the only testing institutes certifying sealed lead acid batteries,our VdS approved batteries are indispensable for the reliability of many security and fire systems.The VdS quality seal certifies that our batteries are of optimum quality for use in fire,security and life safety applications. SPEC Approved) i Dimensions: Nominal float service Terminal Model Voltage 68-F(20-C) 20-hr 10-hr 5-hr 1-hr Length Width Height Total Height Weight Type Years 1.80V/cell 1.80V/cell 1.75V/cell 1.60V/coll inch mm inch mm inch mm inch mm His. kgs. PS-6100VdS 6 10-12 10.0 9.3 8.5 6.3 5.94 151 2.01 51 3.70 94 3.94 100 4.30 1.95 F1 PS-1212VdS 12 5 1.2 1.1 1.0 0.7 3.82 97 1.69 43 2.05 52 2.28 58 1.26 0.57 F1 PS-1221VdS 12 5 2.1 1.9 1.7 1.2 7.01 178 1.38 35 2.36 60 2.60 66 2.12 0.96 F1 PS-1230VdS 12 5 3.4 3.2 2.9 2.1 5.28 134 2.64 67 2.38 60.5 2.62 66.5 2.98 1.35 F1 PS-1270VdS 12 5 7.0 6.5 5.8 4.3 5.94 151 2.56 65 3.70 94 3.94 100 4.81 2.18 F1/F2 PS-1212OVdS 12 5 12.0 11.2 10.2 7.5 5.94 151 3.86 98 3.74 95 3.98 101 7.72 3.5 F1 PS-1217OVdS 12 10-12 17.0 16.0 14.2 9.8 7.15 181.5 3.03 77 6.59 167.5 6.59 167.5 12.57 5.7 T12 PS-1226OVdS 12 10-12 26.0 24.2 22.1 16.3 6.56 166.5 6.89 175 4.65 118 4.92 125 17.20 7.8 T12 PS-12380VdS 12 10-12 38.0 36.1 31.1 22.0 7.76 197 6.50 165 6.69 170 6.69 170 29.10 13.2 T6 PS-12450VdS 12 10-12 45.0 42.0 36.6 26.0 7.76 197 6.50 165 6.69 170 6.69 170 32.00 14.5 T6 PS-1265OVdS 12 10-12 65.0 61.8 53.0 37.7 13.70 348 6.57 167 7.01 178 7.01 178 46.30 21 T6 GLOBAL HEADQUARTERS POWER-SONIC EMEA FURTHER INFORMATION (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICA) Power-Sonic Corporation Smitspol 4,3861 IRS Nijkerk, Please refer to our website www.power-sonic.com 365 Cabela Dr Suite 300, The Netherlands for a complete range of useful downloads,such as Reno,Nevada 89439 T NIL: +31 33 7410 700 product catalogs,material safety data sheets USA T UK:+44 1268 560 686 T: +1 775 824 6500 T FIR: +33 344 32 18 17 (MSDS), ISO certification,etc. E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. ©2018.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. , • • • All data subject to change without notice.E&O.E FIRE ALARM PERMIT APPLICATION For Instruction/Checklist,please click here Site Address: 19620 67TH AVE NE Project Name: I VECA SNOCO AOC FA 01 Project Valuation: 35000 Preferred Contact: O Owner OO Contractor Project Description: new fully addressable fire alarm system w/ voice evac. wire and installation of devices to be done by others. Approx 125 devices Owner Details Owner Name: Snohomish County Public W Office No.: Email Address: eric.nordstrom@co.snohomi: Cell No.: Mailing Address: 3000 Rockefeller Ave City: Everett State: WA Zip: 98201 Contractor Details Contractor Name: I Security Solutions NW Office No.: Email Address: katies@ssnw.co Cell No.: 564-243-8526 Mailing Address: 1619 N State St City: Bellingham State: I WA Zip: 98225 L&I Contractor License Number: 1 SECURSN770MF Expiration Date: e7/e5/2e27 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application—review and approval required TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal lto2 $ 75.00 = $0 3 to 5 $ 125.00 = $Q 6to 10 $ 175.00 = $0 11 to 20 $ 225.00 = $ 21 to 40 $300.00 = $E 41 to 100 IF $375.00 11 = $Q 101 to 200 $475.00 = $Q >200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $500.00 + $ _ $ FACP/TRANSMITTER ModificationIF- $125.00 = $ PERMIT FEE SUBTOTALIF $ O NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $ 350.00 = $ 101 to 200 IF $ 475.00 = $ 475 >200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200 = $ 200 PERMIT FEE SUBTOTAL IF = $ 675 Plan review fee due at time of submittal TOTAL PERMIT FEE $K75777 PLAN REVIEW FEE $ 738.64 Processing/Technology Fee $ 25.00 TOTAL $ 1438.64j I hereby certify that I am the Owner OApplicant Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Print Name: Katie Smith Date: 01/13/2026 City of Arlington 14 (11 (0/1 18204 59th Avenue NE, Arlington, • • Washington 98223 Phone: 360-403-3551 jNG� WASHINGTON C Invoice Number: 26-0030 INVOICE Invoice Date:January 13, 2026 Account Number: 1509490628 Bill To: Invoice Questions? Security Solutions NW Phone: 360-403-3551 1619 N State St Bellingham, WA 98225 Email: ced@arlingtonwa.gov Invoice Due Date:January 13, 2026 Record Number: Permit A26-0035 Parcel Number: 31051500101500 Location: 19620 67TH AVE NE Date Description Paid Date Amount Paid Balance January 13, Fire System Plan Review(006.345.83.00.02) $480.12 2026 TOTAL: Permit Fees $480.12 $480.12 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by January 13, 2026 Number Number This Invoice 26-0030 1509490628 1$480.12 Security Solutions NW 1619 N State St Bellingham, WA 98225 City of Arlington 14 (11 (0/1 18204 59th Avenue NE, Arlington, • • Washington 98223 Phone: 360-403-3551 jNG� WASHINGTON C Invoice Number: 26-0162 INVOICE Invoice Date: February 18, 2026 Account Number: 1825935702 Bill To: Invoice Questions? Katie Smith Phone: 360-403-3551 1619 N State St Email: ced@arlingtonwa.gov Invoice Due Date: February 18, 2026 Record Number: Permit A26-0035 Parcel Number: 31051500101500 Location: 19620 67TH AVE NE Date Description Paid Date Amount Paid Balance February 4, FACP/Transmitter-New Fee(006.322.10.00.01) $200.00 2026 February 4, Fire Alarm System Permit Fee(006.322.10.00.01) $475.00 2026 February 4, Processing/Technology(320.341.43.00.02) $25.00 2026 TOTAL: Permit Fees $700.00 $700.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by February 18, 2026 Number Number This Invoice 26-0162 1825935702 1$700.00 Katie Smith 1619 N State St 4rtk( tot( WASHINGTON Permit Information - - , 1 'nformat;^ Permit# 26-0035 Parcel # 31051500101500 Building ID Location 19620 67TH AVE NE Permit Type Fire Permit Use Fire Alarm Zone Permit # Subdivision Applicant Name Katie Smith Address 1619 N State St Applicant Email permits@ssnw.co Phone 3607344940 Cell Owner Name Snohomish County Public Works Address 3000 Rockefeller Ave Owner Email eric.nordstrom@co.snoho Phone Cell mish.wa.us Contractor Security Solutions NW Address 1619 N State St, Bellingham, WA 98225 Contractor Email katies@ssnw.co Phone 564-243-8526 Cell Type/Improveme Accessory/Struct nt ure Current Use Proposed Use Current Zoning 0 Proposed Zoning Project Cost 35000 Project Value 35000 Current Use And New fully addressable fire alarm system w/voice evac. wire and installation of devices to be done by others. Proposed Approx 125 devices. Changes Lot Width Lot Depth Map Number Total Area of Building &Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions/ Variances ©Community Development Online Portal Page 1 of 6 July 28, 2026 09:41AM WASHINGTON Structure Information Structure Type # of Stories Usable Floor Area (Sq Ft) Structure Height # of Units Load per Floor (Lbs) Sign Dimensions # of Bedrooms # of Bathrooms Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth Material Foundation Information Setbacks Front& 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width # of Off Street # of Off Street Parking Loading Miscellaneous Information ©Community Development Online Portal Page 2 of 6 July 28, 2026 09:41AM WASHINGTON Contractors License # Business Name Type Contact SECURSN770MF Security Solutions NW General Contractor Katie Smith ©Community Development Online Portal Page 3 of 6 July 28,2026 09:41AM WASHINGTON Inspections Inspection # Inspection Type Status Date Inspector 26-0489 Fire- Fire Alarm Final Pass July 24, 2026 Brian Grieve ©Community Development Online Portal Page 4 of 6 July 28,2026 09:41AM 4rtk( tot( WASHINGTON Contacts Contact Name Type Project Address Phone Snohomish County Public Previous Owner 3000 Rockefeller Ave Works Snohomish County Public Owner 3000 Rockefeller Ave Works Katie Smith Others 1619 N State St 360-734-4940 Katie Smith Applicant 1619 N State St 360-734-4940 Security Solutions NW Contractor 1619 N State St, 564-243-8526 Bellingham, WA 98225 ©Community Development Online Portal Page 5 of 6 July 28, 2026 09:41AM 4rtk( tot( WASHINGTON Fees Fee Type Date Debit Credit Balance Permit Fees January 13, 2026 $700.00 $700.00 $480.12 $219.88 $700.00 $-480.12 T O T A L $700.00 $1,180.12 $-480.12 ©Community Development Online Portal Page 6 of 6 July 28, 2026 09:41AM WASHINGTON Permit #26-0035 Location:19620 67TH AVE NE Routing Details ✓ Department: Permit Tech Intake Review - Approved: February 5, 2026 - Status: Approved Permit Application #A26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at January 13, 2026 03:50PM Status: Pending Activity Type: Pending Payment Hello, Your invoice for the plan review fee is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0035 Location:19620 67TH AVE NE- by LaNay Hendrick- Permit Technician at February 4, 2026 10:04AM Status: In Progress Activity Type: Application Sent Hello, At your request, here is your invoice again. Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. LaNay Hendrick City of Arlington Permit Technician ©Community Development Online Portal Page 1 of 5 July 28, 2026 09:42AM 4rtk( tot( WASHINGTON Ihendrick@arlingtonwa.gov 360-403-3437 Permit Application #A26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at February 5, 2026 08:58AM Status: Approved Activity Type: In Review Application is ready for review. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 ✓ Department: Building - Approved: February 18, 2026 - Status: Approved Permit Application #A26-0035 Location:19620 67TH AVE NE- by Kevin Olander- Building Official at February 18, 2026 01:02PM Status: In Progress Activity Type: Application Sent Kevin Olander City of Arlington Building Official kolander@arlingtonwa.gov 3604033433 Permit Application #A26-0035 Location:19620 67TH AVE NE- by Kevin Olander- Building Official at February 18, 2026 01:07PM Status: Approved Activity Type: Application Sent Kevin Olander City of Arlington Building Official kolander@arlingtonwa.gov 3604033433 ✓ Department: Fire - Approved: February 10, 2026 - Status: Approved Permit Application #A26-0035 Location:19620 67TH AVE NE- by Steve Goforth -Assistant Chief/Community Risk Reduction at February 10, 2026 11:56AM Status: Approved Activity Type: Application Sent Steve Goforth North County Regional Fire Authority Assistant Chief/Community Risk Reduction sgoforth@northcountyfireems.com @ Community Development Online Portal Page 2 of 5 July 28, 2026 09:42AM 4rtk( tot( WASHINGTON 360-629-2184 ✓ Department: Permit Tech Final Approval - Approved: July 28, 2026 - Status: Closed Permit Application #A26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at February 18, 2026 01:30PM Status: Pending Activity Type: Pending Payment Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment and I'll provide a copy of your issued permit and approved documents. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician 11 at February 23, 2026 04:1OPM Status: Approved Activity Type: Permit Issued Admin - Hannah Hardwick City of Arlington Fire Permit Technician 11 hhardwick@arlingtonwa.gov 360-403-3549 Permit #26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician 11 at February 23, 2026 04:22PM Status: Approved Activity Type: Permit Issued Hello, Please find attached the issued building permit. Please review any conditions and reach out should you have any questions. Inspection request instructions can be found on the permit. ©Community Development Online Portal Page 3 of 5 July 28, 2026 09:42AM 4rtk( tot( WASHINGTON Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit #26-0035 Location:19620 67TH AVE NE - by Admin - Hannah Hardwick- Fire Permit Technician II at February 26, 2026 11:44AM Status: Approved Activity Type: Permit Issued Hello, Please find attached the issued building permit. Please review any conditions and reach out should you have any questions. Inspection request instructions can be found on the permit. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Manual Closure - Permit#26-0035 Location:19620 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at July 28, 2026 09:36AM Status: Closed Activity Type: Documents Review The following permit has been closed manually. Permit#26-0035 Location:19620 67TH AVE NE @ Community Development Online Portal Page 4 of 5 July 28, 2026 09:42AM WASHINGTON Record Actions Permit Application #26-0035 Location : 19620 67TH AVE NE By Katie Smith at January 13, 2026 03:15PM Good afternoon - This is my first application with the City of Arlington so I just want to confirm you've received our application and to confirm if you are needing anything else from us. Thanks, Katie Smith 564-243-8526 katies@ssnw.co New Permit Application #A26-0035 Location: 19620 67TH AVE NE By Admin - Hannah Hardwick- Fire Permit Technician II at January 13, 2026 03:18PM Hello, A new permit application has been submitted for review. Please login to your CIVICGov Web Application account and visit the link below to view the permit details. https://www.civicgov4.com/wa_arlington/permits/details/163 If you cannot click on the link above, please copy and paste the entire link in the browser address bar. Sincerely, CIVICGov Team. Condition #1 Added By Admin - Hannah Hardwick- Fire Permit Technician 11 at February 23, 2026 04:11PM Condition: Adhere to approved plans. Condition #2 Added By Admin - Hannah Hardwick- Fire Permit Technician II at February 23, 2026 04:11PM Condition: Permit shall be onsite for inspections. Condition #3 Added By Admin - Hannah Hardwick- Fire Permit Technician II at February 23, 2026 04:11PM Condition: Call for inspections Inspection #26-0489: Result- Pass By Brian Grieve - Development Services Inspector at July 24, 2026 11:21AM Fire- Fire Alarm Final Inspection #26-0489: Result- Pass Same time as others Manual Closure - Permit #26-0035 Location:19620 67TH AVE NE By Admin - Hannah Hardwick- Fire Permit Technician II at July 28, 2026 09:36AM The following permit has been closed manually. Permit#26-0035 Location:19620 67TH AVE NE @ Community Development Online Portal Page 5 of 5 July 28, 2026 09:42AM 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Fire - Fire Alarm Permit Parcel:31051500101500 Permit#:26-0035 Permit Address:19620 67TH AVE NE Date Issued:February 23,2026 Description of Work:New fully addressable fire PERMIT EXPIRES 180 DAYS alarm system w/voice evac.wire and installation of AFTER DATE OF ISSUANCE. devices to be done by others.Approx 125 devices. Valuation:$35000 Code Year:2021 OWNER APPLICANT CONTRACTOR Snohomish County Public Works Katie Smith Security Solutions NW 3000 Rockefeller Ave 1619 N State St 1619 N State St,Bellingham,WA 98225 3607344940 564-243-8526 eric.nordstrom@co.snohomish.wa.us permits@ssnw.co katies@ssnw.co registration number:SECURSN770MF PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved plans. 2.) Permit shall be onsite for inspections. 3.) Call for inspections INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance January 13, Fire System Plan Review(006.345.83.00.02) $480.12 2026 February 4, FACP/Transmitter-New Fee(006.322.10.00.01) $200.00 2026 February 4, Fire Alarm System Permit Fee(006.322.10.00.01) $475.00 2026 February 4, Processing/Technology(320.341.43.00.02) $25.00 2026 TOTAL: Permit Fees $1,180.12 $1,180.12 Credit/Debit Card 199 Payment Successful January 14, 2026 $480.12 $700.00 Credit/Debit Card 331 Payment Successful February 23, 2026 $700.00 $0.00