Loading...
HomeMy WebLinkAbout20251113_PJA25-0064_TCP SINCE 2002 SIGN SPACING = X THIS TCP IS "STAND ALONE"AND SHALL NOT TRAFFIC CONTROL PLAN FREEWAYS & EXPRESSWAYS 55/70 MPH 1soot BE ACTIVE CONCURRENTLY WITH ANY OTHER TCP ARLINGTON,WA RURAL HIGHWAYS 60/65 MPH 8001t IN RURAL ROADS 45/55 MPH 500't MANDATORY RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350't W E Gw FLAGGERS SHALL CONFORM TO RURAL ROADS & URBAN ARTERIALS 25/30 MPH 200't(2) ✓ RESIDENTAL& BUSINESS DISTRICTS WAC468 95.3015,468.95 302&296.155.305 S sy g $ URBAN STREETS 25 MPH OR LESS 100't(2) NOT TO SCALE (1)ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE Temporary One-Lane, Two-Way Operation RAMPS,AT-GRADE INTERSECTIONS AND DRIVEWAYS. (2)THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT E1B E 3rd St closed between French Ave&Lenore Ave. ROADWAY CONDITIONS. O FLAGGERS shall alternate traffic, as needed. O Pedestrian escort shall safely guide pedestrians through ONE LANE,TWO-WAY TRAFFIC TAPER SPECS work area. TAPER TYPE LENGTH(feet) #OF DEVICES Presidents Elementary School O Community Transit route not prese, UPSTREAM TAPER 50' TO 100' 6 DEVICE MIN. 505 3rd St O Parking lane closed with work area. Arlington,WA 98223 O Bicycle lane not present. DOWNSTREAM TAPER 50' TO 100' 6 DEVICE MIN. (360)618-6240 EST. 2016 O REASON:To remove/replace control panel on PLI 168060 TABLE(1) If work performed during school hours, w CHANNELIZATION DEVICE contractor MUST coordinate work and all associated work. z SPACING (FEET) time/dates with school administrators a MPH TAPER TANGENT D D- 50/65 10 TO 20 80 0 O 35/45 10 TO 20 60 H 25/30 10 TO 20 40 *W20-1 O D/W U x w W }w W� W I mo �T of o Ir 00 �o z'n Ua tW20-4 ROAD WORK Q V) W N J U7 SHALL MAINTAIN 11' ROAD AHEAD W 0 M ¢ MIN.LANE WIDTH W20-7a W20-1 Of _ =N _ do o_ () a_w c� E 3 ST 11111111FF LLJ LU O Cn 0 IIYIIIII YYIIYI I1111 Do w TWO-WAY c 0 0 3 a ROAD I TRAFFIC TAPER **PED c w N o W WORK ONE LANE O > DO 0� x � AHEAD ROAD �� ESCORT 00 ¢ O a ^D O �_ W20-1 04 AHEAD W20-4 I W20-7a 0 # 1 O_ H N a o< o:W 0 300-<1 I _W W ROAD U WORK W * AHEAD ¢ I Z z 1 W20-1 6 ROAD �/ u = WORK H W A (A N Q AHEAD Z Q Z W 1? I W20-1 ¢ W20-7a f w O >Q W O W W o O 90 t a W MANDATORY ® a N oQ RE DURING HOURS OF DARKNESS, = Z PREPARED TO FLAGGER STATIONS SHALL BE STOP W20-7b ILLUMINATED WITHOUT CAUSING GLARE TO THE TRAVELING PUBLIC USING PORTABLE LIGHT TOWER OR APPROVED ALTERNATIVE MANDATORY WAC 296-155-305 SECTION 9(c) MANDATORY ** ROAD PEDESTRIAN ESCORT STOP WORK,SECURE PASSABLE WORK DURING NON-WORKING HOURS,TRAFFIC CONTROL SHALL BE ADA COMPLIANT PEDESTRIAN ACCESS ON EXISTING SIDEWALK AHEAD CLEAR ZONE MUST BE FREE OF OVERHEAD HAZARDS W20-1 REMOVED AND ROW SHALL BE OPENED TO ITS FULL WIDTH (4 MIN) WHEN PEDESTRIANS ARE MOVING THROUGH WORK AREA Know what's below. 1 811 before you dig. GENERAL NOTES: -FOR CITY OFARLINGTON USE- z_ 1. ALL SIGNS AND SPACING SHALL CONFORM TO THE MUTCD. cn 2. NOTIFY LOCAL EM ERGENCY SERVICES OF CLOSURE TIMES AND a DATES(OPTIONAL). c� 3. SIGN SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROAD 0 CONDITIONS. 4. ALL SIGNS MIN. 48"x 48", B/O UNLESS OTHERWISE SPECIFIED. = w o 5. CHANNELIZATION DEVICES ARE 28" REFL. CONES(see TABLE(1) x N p N m LO for spacing distances). ¢ n O Z U¢ I 6. ALL SPACING MAY BEADJUSTED TO ACCOMMODATE AT-GRADE W 0< w INTERSECTIONS AND/OR DRIVEWAYS. Sn0 SMART Project - DA-78 work Order 100061454 z n H ~w z z > 0' o O ¢ O w S N U011H a �