Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18725 67th Ave Ne Ste 106_P26-0158_2026
FIRE ALARM PERMIT APPLICATION Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 Type of Permit: ❑ New Installation GJ System Modification ❑ Phased Installation Property Address: i�1�5 ���h N`C,110e, K3E, Project Valuation: Lot#: Parcel ID No.: Preferred Contact: 0 Owner [Contractor Project Description: Fire glafW +Chan+ l m rbVL°X' end Owner Name: fo n V1 rao Home No.: Email Address: C2 U P ckraridu)Cuoi c- ncc }, Cell No.: Mailing Address: bY. 1 City: PK II r) 1(O State: Zip: (%2 Contractor Name: ( ayid Secur'l*-AOffice No.: Email Address: elf NIA F7 rC .C6M Cell No.: Mailing Address: City: i'1 State: Zip: 9S2 Z L&1 Contractor License Number: F I?.14 F Zq2KkjExpiration Date: 2 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES AND TWO (2) SETS OF THE FOLLOW: ❑ Complete and Scaled Plans ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans, if applicable NOTE: All Central Station Monitoring must be UL or FM listed. I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules arid regulation of the State of Washington. �kim �(AI 5y0 56rd Signature Print Na Date FOR STAFF USE ONLY PERMIT# ACCEPTED BY: DATE STAMP REV12,20Z0 Page 1 of 2 FIRE ALARM SYSTEMS (105.7.3) **DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES-shall be paid at time of application submittal Less than $5,000.00 = $100.00 (Table 4-10) $5,000.00&over—based on valuation (Plan Review Fee is 65%of Buildi ig Permit Fee Calculation per Table 4-1) REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application -review and approval require Rei nspecti on/Phased Installation fee is charged per hour(1 hour mini um) $75.00 71 7 S s"..a Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $17S.00 - $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 2rn, OU 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 1011 additionaI devices(roundup) Total Number of Devices = 22 $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ 0Q C)o OX, ' Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 perloil additional devices (round up) Total Number of Devices = $500.00 + $ _ $ FRCP/TRANSMITTER New $200.00 = $ PERMIT F E SUBTOTAL $ PERMIT FEE TOTAL $�jQb•CO PLAN REVIEW FEE $ Pro cessing/Technology Fee $25.00 TOTAL REV12.2020 Page 2 of 2 xav&>taa&0 7>Ayeg" �r/.Z )&M5- 14 Avb; NC /42�.taw.Tu�J h/�A g�zZ3 City of Arlington Section 9 Building Department APPROVED Battery Calculation Kevin Oland - 03/09/2026 No changes authorizeze d unless approved by the Building Official 9.1 Calculating Current Draw and Standby Battery This section enables you to determine the current draw and standby battery needs for your installation (18 Ampere Hours maximum). Batteries larger than 18 AH will not fit into the main control cabinet, and must be housed in the RBB Accessory Battery Cabinet. See Section 3.8.2 for battery installation. Lines A through D have been completed for you. Complete the remaining instructions in Table 9-1 to determine battery size requirements. Table 9-1: Current Draw Calculations Device Number of Current per Device Standby Alarm Devices Current Current Standby: 140 mA 140 mA Main Control Panel I Alarm: 590 mA 590 mA Standby: 45 mA mA SKE-I.N4 Alarm: All Channels 250 mA mA SKE-LN6 Standby: 35 mA mA Alarm: All Channels 120 mA mA SKE-SRM Standby: 30 mA mA Alarm: 30 mA mA Standby: 10 mA mA SKE-V70 Alarm: 70 mA mA A Current Subtotals: /400 MA "O mA Notification Devices Refer to device manual for number of devices and current ratings. Full Load (50 watts)* loX Alarm: 2250 mA ySC;p mA B Current Subtotals: /Ljo mA ICOfv mA C Total current rating of all devices in system (add TOTALS OF A-C) X .001: ly A 1.0LI A D Number of standby hours. (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): 7&1 H F Multiply lines C (standby current) and D: Total standby All ` A1I F Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) �29 H G Multiply lines C (alarm current) and F: Total alarm AH AH 11 Add lines E and G. (AH = Ampere Hours) Total AH required 3�(s2 All *If less than 50 watts are used, calculate 45 mA per watt. 151267 9-1 N m3a 1 Z=N 0LLLa mZm Oac c.i= aa�a I B I (E)A U 15td a IU _ B BREAK ROOM ROOM 5 B r a° a t5cd I REST � ROOM Ism txd I B ® ® ° Eon B 00 ® ® DESIGNER: NICET LEVEL 33 ID#R1148093 / KITCHEN LICENSE: B °," ;o, 15cd 0` BROSSJB9511-7 REFERENCE: ROOM 4 / E7)Scd EOL ❑ — J 75ca 2021 IFC AND 2019 NFPA 72 / ° •o; _ lsaa C .o. e ❑ 2 I HB1 CKT 5 / ~ M W N z M F B ROOM 3 B B Q W Z / A U o 75cd / ❑ W 0 0 c; 0 Q _ IB V 1xd 15cd O Lo 15cd .o. ;o; REST B �— (R) H ROOM It O 0 (R) 0 2 B A ) - 7 Z t5cd Z � O LOBBY (R) REST A A —— OFFICE ROOM D�� B I 0 ° �) Q o = ~ 15cd r d o-d -1sctl EVAC FEED - e 15cd B ROOM 2 / ,o e ISSUES I / •(R) REV DATE DESCRIPTION 75cd / ROOM 1 / REST PACKAGE ROOM ROOM o•C / D 0 HB1 CKT 1 HB1 CKT 7 B (R) A J D \ 7 TO FACP ❑ TITLE: HB1 CKT 6 \ \ n �2 FIRE ALARM \\(R) 'o•1xd ;(E) RISER OOM City of Arlington PLAN (') U E❑L B Building Department wP APPROVED X g Kevin Olander-03/09/2026 DATE: € No changes authorized unless approved by DECEMBER 6,2025 y the Building Official PROJECT NO.: s R L 25-039 SHEET: a 1 FIRE ALARM PLAN `eV SCALE:3/16"=1-0° FA- I � 0 4' 8' 12' y o a D SCALE: 3/16"=1'-O" N m3a Z=N M O�N O(Dw t m z m Ci¢J= as o U a 0 v- -c - EQUIPMENT LEGEND DEVICE QUANTITY PART NUMBER DESCRIPTION BACKBOX EVAC FEED SYMBOL /-y^7 r 15c0 75cd /'d 75cd EXISTING SILENT KNIGHT FIRE ALARM H81 CKT 7 FRCP (E) 6808 INCLUDED ;o; ;o; ;o; ;o; CONTROL PANEL (E) C — — — D� DESIGNER: B — — —�— HBt 1 PS SILENT KNIGHT HORN BOOSTER INCLUDED JEFF BROSSARD 75cd 75cd 15cd \ 1� 15cd 15cd H81 CKT 6 75cd IS<d EVAC 1 SKE-450 SILENT KNIGHT VOICE EVACUATION NCET LEVEL 3 ID#148093 ;o; ;o; ;O; 'O I'd, ;o; ;O ;o; EOL SYSTEM LICENSE: C C B = 4 SK-PHOTO-W SILENT KNIGHT SMOKE DETECTOR 4 SQUARE X 1-7/8"DEEP BROSSJB951L7 75cd 75cd REFERENCE: HB1 CKT 5 75cd 15cd 75cd EDL O N 4 SWLED SPECTRA ALERT MOUNT 4 SQUARE X 1-7/8"DEEP C C;o; ;o; 2021 IFC AND 2019 NFPA 72 e EOLN 7 P2WLED SPECTRA ALERT WALL MOUNT 4 SQUARE X 1-7/8"DEEP HORN STROBE HB1 CKT 1 75cd ,"Wp 15cd IScd EDON 5 SPSWLED SPECTRA ALERT CEILING MOUNT 4 SQUARE X 1-7/8"DEEP HORN STROBE 2 2 2 2 D� N SPECTRA ALERT WALL MOUNT LOW A e = C 5 SPSCWLED FREQUENCY SOUNDER STROBE 4 SQUARE X 1-7/8"DEEP TO 120 VAC UNSWITCHED DEDICATED CIRCUIT ------ e o N TO TELCO ROOM FACP(E) H61 EVAC ,y 1 EXISTING WEATHERPROOF HORN STROBE -- M B (•) PROVIDED AND INSTALLED BY OTHERS W N FIRST FLOOR Lu 00 Vim/ --------- EXISTING DEVICE TO REMAIN z NEW OR EXISTING DEVICE RELOCATED ` w z FIRE ALARM ONE-LINE RISER DIAGRAM NINDICATES CANDELA z O SCALE:NONE (E) INDICATES EXISTING w (R) INDICATES EXISTING DEVICE RELOCATED OR REMOVED Q Q z C INDICATES CEILING MOUNT 00 EOL— END OF LINE RESISTOR Q �/�-� 0 \Y 0 Loz SEQUENCE OF OPERATIONS DESIGNED AUDIBILITY LEVEL PER WIRE LEGEND (V O OCCUPANCY CLASSIFICATION IM` F-- w r F u Z GROUP A 70db TYPE DESCRIPTION 7 V c c z¢ L rl ° A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE z GROUP B 70db z z O J z a ' �o u o a oz z� J� o �z S2z o 0 z a � 5) O B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE O Ei N ¢N a z F v+F GROUP E 60db Q z a a s m Z 3: �^ �_ GROUP F 95db z C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE vi w z z�w m ¢z �O mI >I O O o O E5 w r D 16 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE z'u z w ¢o g¢ °z w z GROUP M 55db aLL WATERFLOW DEVICE X X X X GROUP R 50db GENERAL NOTES: TAMPER DEVICE X X X GROUP S 45db 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. ISSUES 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO REv DATE DESCRIPTION BUILDING PULL STATION X X X X BE IN CONDUIT. BUILDING SMOKE DETECTOR X X X X 3. ALL JUNCTION BOXES, COVERS,AND BACK BOXES ARE TO BE PAINTED RED. AC POWER LOSS X X X 4. PULL STATIONS ARE TO BE MOUNTED AT 42"TO 48"ABOVE THE FLOOR. LOW BATTERY X X X 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES,AND SPEAKER STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6"BELOW THE CEILING, WHICHEVER IS LOWER. TITLE: 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: FIRE ALARM A) 36"INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES LEGENDS, NOTES 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING,AS HIGH AND RISER AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. DIAGRAM ;^ 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. 8 DATE: DECEMBER 6,2025 i i PROJECT NO.: s City of Arlington 25-039 R Building Department SHEET: APPROVED a Kevin Olander- 03/09/2026 No changes authorized unless approved by FA-2 y the Building Official o Honeywell City of Arlington Building Department ®SILENT* APPROVED WGHT Kevin Olander-03/09/2026 No changes authorized unless approved by the Building Official 6808 Addressable Fire Alarm Control Panel The 6808 is an addressable fire alarm control panel(FACP) that can be configured to achieve an overall point capacity of up to 198 points.It has one built-in signaling line circuit (SLC),which can support 99 System Sensor'(SK)sensors and 99 SK modules or 127 Hochiki°(SD)devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.It also has a built-in,dual- line POTs and IP communicator and optional cellular side-cars. 6808 The 6808 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function It supports a variety of devices,including the buttons to help automate tasks and reduce time spent at the panel. 6860,5860,and 6855 remote annunciators, 5824 serial parallel printer interface module(for SWIFT°wireless compatibility provides options forwireless detection printing system reports),the 5496 NAC expander, through a Class A mesh network.It is ideal for hard-to-wire locations, 5895XL power module,and SK or SD devices. buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has Form C trouble relay,and two programmable Form C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. FEATURES & BENEFITS • Capable of providing • Convenient 6860 annunciator with Programmable date 125 software zones up to 198 points to field-upgradeable a 4 x 40 large display, setting for automatic and 125 output satisfy smaller firmware and 4 programmable and convenient groups for flexible installation needs . Integrated dual path function buttons. Daylight Saving Time design options • Connect up to 17 IP and POTs Free-up time spent at changes panels on one site with communications and the panel.Program Built-in dual phone or convenient single- optional cellular them for simpleline and digital alarm point access using the side-cars for reliable complex tasks. communicator/ SK-NIC Network backup Built-in USB interface transmitter(DACT)for Interface Card. for convenient and additional Connected panels can quick programming communication have mixed compatible options FACP models. 6808 Product Information SIGNAL LINE CIRCUIT(SLC) non-coded)signaling services. The 6808 SLC loop supports multiple „ • UL Listed device types,maintenance alerts,and a CSFM 7165-0559:0502 built-in sensortestto complywith NFPA 72 calibration testing requirements. • FDNY COA#6246 INDICATOR LIGHTS • FM approved • General Alarm(Red):Flashes if in • Seismic(CA)(pending) alarm;solid when alarm is silenced 6808 KEYPAD ORDERING INFORMATION • Supervisory(Yellow):Flashes if a PROGRAMMING 6808:Addressable Fire Alarm supervisory condition exists;solid Control Panel.(Red cabinet). The 6808 system offers several options when supervisory is silenced to simplify and speed-up programming. • System Troubles(Yellow):Flashes o COMPATIBLE ANNUNCIATORS Y JumpStart° AutoProgramming if a trouble condition exists; minimizes programming required to 6860:4x40 LCD remote fire annunciator solid when trouble is silenced start a new system.The built-in keypad, a 160 characterr nnunciator lines and up to or the 6860,5860 or 6855 remote s)per system;four • System Silenced(Yellow): programmable buttons On when an alarm,trouble or annunciators give you on-site access to current system programming.You 5860:4x20 LCD remote fire supervisory condition has been Y p g g silenced but not yet cleared can also program the system using annunciator.5860 is gray;5860R is red the Honeywell Fire Software Suite 6855:4x20 LCD remote fire • System Power(Green):Flashes annunciator forAC failure;solid when (HFSS),which is Windows'based. 5865-3 or 5865-4:LED annunciators power systems are normal SOFTWARE TOOLS can display up to 30 LEDs(15 red and USER INTERFACE SKST.Silent Knight Selection Tool 15 yellow).The 5865-4 has key switches The 6808 built-in 4 x 20 annunciator provides the installer or design architect for silence and reset,and a system with 80 character LCD display with a Windows°software system trouble LED. and large easy-to-use tactile configuration tool to create a detailed 5880:LED/10 module has 40 touchpad can be used for system Bill of Material(BOM)and battery programmable LED outputs and eight operation,programming and calculations. supervised dry contact inputs which are maintenance.It has five LEDs for HFSS:Honeywell Fire Software Suite useful for custom applications.You can alarm,supervisory,system trouble, provides communication and panel use up to eight 5880 modules on one system silenced and system power. programming,detector status,event control panel for maximum flexibility. System operations include silencing history and additional data.Requires a Its compact size allows mounting inside alarms and troubles,resetting alarms Windows-based computer. the annunciator,or in an accessory and the display of alarm troubles and ADDITIONAL INFORMATION cabinet. memory.The system's non-volatile Twisted-unshielded pair event history buffer stores 1,000 wire is recommended. events for viewing from the built- The 6808 also has 13 preset in or remote annunciator.System notification cadence patterns operations can be initiated with a (including ANSI 3.41). mechanical firefighter's key or a valid 4-to 7-digit operator's code. AGENCY LISTINGS AND APPROVALS NFPA 13,NFPA 15,NFPA 16,NFPA 70,N FPA 72:Central station;remote Signaling;Local Protective Signaling Systems;Auxiliary Protected Premises Unit;Water Deluge releasing service. Suitable for automatic,manual, waterflow,sprinkler supervisory(DACT 6808 COMPATIBLE DEVICES AND B200S-LF:Low-frequency intelligent smoke detector ACCESSORIES sounder base WSK-PHOTO-T.Wireless Multi-criteria See the data sheets listed below for a B224RB: Relay base photoelectric smoke detector with thermal complete listing of the SK,SD or SWIFT B224B1: Isolator base detection(135°Ffixed temperture)and devices. B510W 4"base 53623:SK Devices Data Sheet SO COMPATIBLE ADDRESSABLE WSK-HEAT:Wireless Heat,(1350Ffixed 53624:SD Devices Data Sheet DEVICES temperture)and B510W 4"base 350614,350616&350618:SWIFT SD505-6AB:Addressable 6"base WSK-HEAT-ROR:Wireless heat,ROR wireless devices SD505-6113:Addressable 6"short circuit (135°F fixed temperture)and B510W 4" For a complete and current listing of isolator base base compatible devices and accessories go to SD505-6RB:Addressable 6"relay base WSK-MONITOR:Wireless monitor module www.siLentknight.com SD505-6SB:Addressable 6"sounder base WSK-RELAY:Wireless relay module Important:You cannot mix SK and SD SD500-AIM:Addressable input module W-USB:SWIFT Tools USB transceiver used devices in the same fire alarm system. (switch input) for communication with SWIFT devices SD500-ANM:Addressable notification SK COMPATIBLE ADDRESSABLE module SBUS ACCESSORIES DEVICES SD500-ARM:Addressable relay module 5496:A 6 amp notification power expander SK-ACCLIMATE:Multi criteria photoelectric smoke detector with thermal SD505-DTS-K:Remote test switch and with four power-limited notification phot phut F fixed temperture LED indicator for the SD505-DUCTR appliance circuit outputs. SK-BEAM:Reflected beam smoke detector SD505-DUCT:Addressable Duct Smoke 5883:Relay Interface.Provides 10 Form C without test feature Detector. relays. without Reflected beam smoke SD505-DUCTR:Addressable Duct 5824:Serial/Parallel Printer Interface detector with test Reflected b Detector housing with relay base. Module for printer connection. detector "" SK-CONTROL:Supervised control module SD505-HEAT:Absolute temperature 5895XL:Power Supply with six Flexputr heat detector.Trip point range from circuits,and two Form C relays.Max.16 per SK-CONTROL-6:Six circuit supervised 135°F-150°F(0°C-37°C). system. control module SK-DUCT:Photoelectric duct smoke SD500-LIM:Addressable Line isolator 5815RMK:Remote mounting kit. module Dimensions:10 3/8"W x 10-3/16"H x 3"D detector with extended airspeed range SD500-M IM:Addressable Mini input SK-FIRE-CO:Four criteria fire and carbon monitor module(switch input) COMMUNICATION OPTIONS monoxide detector SD505-PHOTO:Photoelectric smoke CELL-CAB-SK:Cellular communicator, SK-HEAT:Fixed thermal detector(135°F) detector metal enclosure with lock/key* SK-HEAT-ROR:Fixed rate of rise detector SD500-PS/-PSDA:Addressable Single or CELL-MOD:Cellular communicator,plastic (135 F) dual action pull station enclosure* SK-HEAT-HT:Fixed high temperature SD500-SDM:Addressable smoke detector *Sole path,powered by panel. thermal detector(190°F) module IPGSM-4G:Dual path fire alarm SK-ISO:Fault isolator module communicator,cellular and/or IP(primary SK-MINIMON:Mini monitor module AUDIBLE/VISIBLE DEVICES or backup,selectable) SK-MONITOR:Monitor module These AV devices are all 2-wire.Color:°R" SK-I13-2:Remote reporting via the Internet. SK-MONITOR-2:Dual input monitor indicates red;"W"denotes white.For a Requires a VisorAlarm°receiver at the module complete listing of Silent Knight AV devices central station SK-MON-10:10 input monitor module go to www.silentknight.com. SK-PHOTO:Photoelectric smoke detector CHSRL/CHSWL:Wall chime/strobe MISC.ACCESSORIES SK-PHOTO-T.Photoelectric smoke CHSCRL/CHSCWL:Ceiling chime/strobe SK-NIC:Network Interface Card.Provides detectorwith thermal(135°Ffixed CHRL/CHWL:Watt chime a common communications link forthe 6808. temperture) HRL/HWL:Wall horn SK-NIC-KIT:Installation Accessory Kit SK-PHOTOR:Photoelectric detector with P2RL/P2WL:Wall horn/strobe SK-FML:Fiber-Optic Multi Mode, remote test capability PC2RL/PC2WL:Ceiling horn/strobe transmitter and receiver SK-PULL-SA:Addressable single action SRL/SWL:Wall strobe SK-FSL:Fiber-Optic Single Mode pullstation SCRL/SCWL:Ceiling strobe SK-PULL-DA:Addressable dual action pull RBB:Remote battery box accessory cabinet station SPSCRL/SPSCWL:Ceiling speaker/strobe for batteries that are too large to fit in the SK-RELAY:Addressable relay module SPSRL/SPSWL:Wall speaker/strobe FACP cabinet.Dimensions:16"W x 10"H x SPRL/SPWL:Wall speaker 6"D(406mm W x 254mm H x 152mm D). SK-RELAY-6:Addressable Six relay control SK-SCK:Seismic Compliance Kit used to module SPCRL/SPCWL:Ceiling speaker p securely fasten batteries to the fire panel. SK-RELAYMON-2:Addressable Dual relay/ SWIFT WIRELESS DEVICES monitor module SK-ZONE:Addressable zone interface SWIFT is only compatible with module System Sensor(SK)devices.It is not SK-ZONE-6:Six zone interface module compatible with Hochiki(SD)devices. B210LP:6"mounting base WSK-WGI:Wireless Gateway B501:4"Flangeless mounting base WSK-PHOTO:Wireless Photoelectric B200S:Intelligent sounder base 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) For a complete listing of all Overall Dimensions:16.36"W x 26.37H x 3.91"D Four programmable circuits which can be compliance approvals and individually as: certifications,please visit Shipping Weight:32 lbs. programmed www.silentknight.com. Color:Red NACs:3A C 27.4VDC per circuit,power-limited (with a maximum current of 6A) Microsoft,Windows,and ENVIRONMENTAL Auxiliary Power Circuits:3A @ 27.4VDC per circuit, the Windows Logo are Operating Temperature:321Fto 120°F (0°C to power-limited registered trademarksor trademarks of 49°C) Microsoft Corporation. Humidity:0 to 93%relative humidity(non- Supports Class B(Style 4)and Class A(Style 6 or 7) condensing) configuration for the SLC Silent Knight°,Honeywell' and SWIFT°are registered trademarks of Honeywell ELECTRICAL WIRING:See the product manual for wiring details International,Inc 6808 Primary AC:120 VAC @ 60Hz,3.3ATotal Accessory Load:6A C 27.4VDC power-limited This document is not Standby Current 190mA intended to be used for installation purposes.We Alarm Current:250mA tryto keep our product Battery Charging Capacity:7 to 35AH information up-to Battery Size:7AH to 18AH max.allowed in control date and accurate. ci anelcabinet.Larger capacity batteries can be cannot cover or ll anticipate p g p Y applications or anticipate housed in RBB accessory cabinet. all requirements.All specifications are subject to change without notice. For Technical Support, ca11800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford,CT06472 351608IAI11/17 Honeywell 800-328-0103 ©2017 Honeywell International Inc. I' M Q 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499.The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp,remote power supply with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a standalone power supply.The PS Series provides 24 VDC power m for NACs(notification appliance circuits)configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync protocol options.The PS Series also provides auxiliary power,constant or resettable,suited for detectors,annunciators,door holders,and other fire alarm system peripherals.The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five(6 amp model)or seven(10 amp power supply,or a control module,single or corrosion-resistant powder coat chip and model)independently-configurable,power- multi,which may be housed within the scratch-resistant finish limited output circuits for: power supply cabinet • Cabinet designed with ten double —Class B and/or Class A NACs • Ability to cascade up to four power supplies knockouts and a removable door for ease of —Class B and/or Class A resettable or non- • Two(6 amp model)orthree(10 amp model) installation and wiring resettable 24V auxiliary power fully-isolated input/control circuits which • Includes integral battery charger capable of —door holder power can be programmed to any output charging up to 33 AH batteries • Converts from Class B to Class A wiring • Two Form C normally-closed trouble relays • Cabinet can house two 7 AH or 18 AH without losing any outputs using the ZNAC- for AC Trouble and General Trouble batteries PS converter card(sold separately) • 6 or 10 amp full load output,respectively, • Battery charger may be disabled via DIP • Optimal for powering four-wire smoke with 3 A maximum/circuit switch for applications requiring larger detectors,annunciators,and other system • Individual NAC power and trouble LEDs for batteries and external battery charger peripherals requiring regulated power diagnostic efficiency • Removable terminal blocks accommodate • Optional addressable control,monitor,and • Trouble history mode for diagnostic support up to 12 AWG(3.1mm2)wire relay modules and power-supervision relay • Wide range end-of-line supervision value . Works with any UL 864 FACP which utilizes (EOLR-1) (normal:2-27K ohms) an industry-standard reverse-polarity • Configurable for ANSI°Temporal or • Selectable earth fault detection(enable or notification circuit Temporal coded output disable) • UL-Listed NAC synchronization using • AC trouble report delay timer System Sensor',Wheelock',Gentex®,or • Completely configurable via onboard DIP AMSECO°appliances switches,no extra software required • Synchronization can be triggered from • Self-contained in compact,locking cabinet Honeywell FACP NAC/remote sync outputs,cascaded constructed of heavy gauge steel with a SILENT' ® IQVIGHT ORDERING INFORMATION SK-PS6:6.0 A,120 VAC remote charger power supply in a lockable, metal enclosure,red SK-PS10:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red ZNAC-PS:Optional Class A converter card,sold separately SK-CONTROL:Addressable Control Module for one Class B or Class A zone of supervised,polarized Notification Appliances. Notification Appliance Circuit option requires external24 VDC to power notification appliances. SK-RELAY:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch SK-MONITOR:Addressable Monitor Module for one zone of normally open dry-contact initiating devices.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Class B or Class A SK-MONITOR-2:Dual Monitor Module.Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2:Provides two monitored inputs and two Form-C relays.Functions in Class B wiring only SK-CONTROL-6:Six-circuit supervised control module SK-RELAY-6:Six Form-C relay control module EOLR-1:12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP:Battery,12 volt,7.0 AH,5-pack(two required) BAT-12180-BP:Battery,12 volt,18AH,2-pack BAT-12330:Battery,12 volt,33AH SEISKIT-MULTI-1:Seismic kit for the PS Series.Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3—SK-61095:C•3/10/2021 SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS PRIMARY(AC) POWER SECONDARY POWER(BATTERY) SK-PS6:120 VAC,50/60 Hz,5.OA CHARGING CIRCUITSensor' maximum Supports lead-acid batteries only registeredare trademarks of SK-PS10:120VAC,50/60 Hz,6.2 A Float-charge voltage:27.6VDC International, Honeywell maximum Maximum current charge:l.5A Wheelock' . •trademark of Cooper Technologies Company. Wire Size:#12-14 AWG with 600 V • Maximum battery capacity:18 AH(inside - o insulation 'it ' '' of cabinet) • •• • • COMMAND INPUT CIRCUIT Maximum battery capacity: Gentex registered trademark of Potter Trigger Input Voltage:9 to 32 VDC (external cabinet) SignalElectric Company, Trigger Current:2.0 mA(16-32 V);Per PHYSICAL 'NSI'is a registered trademark of Input:1.0 mA(9-16 V) Dimensions:20.0"H x 14.5°W x 3.5"D(cm: the American National RELAY CIRCUITS 50.8H x 36.83W x 8.9D) Institute, Inc. Trouble Contact Rating:4 A at 24 VDC Weight:with two 7Ah batteries is 24 pounds by Honeywell ' -(10.9 kg),with two 18 AH batteries is 39 Inc.ALI rights -' OUTPUT CIRCUITS pounds(17.7 kg) Unauthorized use of document • 24 VDC filtered STANDARDS AND CODES is strictly prohibited. • SK-PS6:TB8-TB9—lA Regulated,3A The SK-PS complies with the following This document is not - •-• to be special applications;TB10-TB12—0.3A standards: used . installation purposes. Regulated,3A special applications NFPA 72:National Fire Alarm Code • • • • •- • SK-PS10:T138-TB11-1.5A Regulated,3A UL 864:Standard for Control Units for Fire up-to-date• • accurate.We cannot special applications;TB12-TB14—0.3A Alarm Systems(NAC expander mode) • - •- applications • Regulated,3A special applications UL 1481:Power Supplies for Fire Alarm anticipate •• '• All • 6.OA(SK-PS6)or 10.0(SK-PS10)maximum Systemsspecifications • - •change total continuous current for all outputs AGENCY LISTINGS AND notice.without APPROVALS Country of origin:USA These listings and approvals apply to the modules specified in this document.In some cases,certain modules or applications may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest listing status. UL Listed:S3511 CSFM:7315-0559:0522 FDNY Approved FM Approved Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 SK-61095 I C 1 03/21 SILENT' www.silentknight.com ©2021 Honeywell International Inc. ®KNIGHT VOICE ' ' • SKE-Series Voice Evacuation System Model SKE-450, Model SKE-450-ZN4 / ZN6 The SKE-Series Voice Evacuation System Aw v provides maximum flexibility to accommodate p your voice evacuation requirements The SKE-Series Voice Evacuation system provides 50 watts of output power. The SKE-Series system consists of several different models, the SKE-450, SKE-450-ZN4 or SKE-450-ZN6. Each model has a built in Digital Message Repeater, power supply and a supervised microphone. All models have two alarm inputs, one triggered by reverse polarity and one by supervised dry contact trigger. The system supports 25 or 70.7 VRMS operation to accommodate most installations. The audio messages are field programmable via the built in microphone, through the line level input, or by downloading via the internet. The models SKE-450-ZN4 (w/4-zone splitter) and SKE-450-ZN6 (w/6- zone splitter) also contain a zone splitter capable of dividing the speaker output into 4 or 6 separate outputs. SKE-Series Voice Evac. the SKE motherboard. No additional System wiring to install makes setup fast and The SKE-450 and SKE-450-ZN4/ZN6 easy. Capable of storing three messages, messages one and two voice evacuation are activated when are built in messages of up to 30 one of the two alarm inputs are tripped. seconds. Message three is field When this occurs the control will output programmable and can be up to 45 a pre-recorded audio message seconds long. corresponding to the alarm input that was tripped. The repetition of the digital Digital Signal Processor-Processes � audio message and the selected digital quality audio, generates tones notification output are completely and provides control functions. programmable. • Supervised Microphone-The built in supervised microphone provides The SKE-450-ZN4/ZN6 comes system paging function and field equipped with a 4 or 6 zone splitter message programming capability. respectively, capable of dividing the • Dead Front Cabinet- Provides speaker output from the amplifier into protection for users, prevents four or six Class B or Class A outputs. tampering with system electronics. The zone splitter also has an All Call . Dedicated relays-Built in form "C" feature that will activate all speaker relays for alarm and trouble increase zones regardless of the individual flexibility and keeps installation cost toggle switch settings. down. Both models provide seven visual • Two Inputs-One reverse polarity indicators for, Speaker Trouble,Alarm, input and one supervised dry contact SKE-Series Voice Microphone Trouble, Command 2 input provides maximum flexibility. Trouble, Earth Ground Fault, Low • Built in system power is capable of Evacuation Battery, and Power. operating the system and charging Listing/Approvals Features system backup batteries. UL Listed • 50 watts of output power on a 25 or ' The SKE-ZN4 zone splitter provides MEA approval 429-92-E Vol. XI 70.7 VRMS speaker circuit. The four Class B or Class A output CSFM Listed speaker circuit can be Class A or B. circuits (each loop can draw 50 Provides maximum flexibility for new watts, with maximum of 50 watts or retrofit jobs. total for whole system).The SKE- conne Voice Messages via ZN6 zone splitter provides six Class • Downl B or Class A output circuits (20 watts SILENT direct connect. If you need a per circuit, with 50 watts max for the different message download it from whole system). Both splatters provide 011 KNIGHT the SK website free of charge! paging by zone or all call. • Digital Message Repeater-Built in to by Honeywell VOICE • SKE-Series Voice Evacuation System Model SKE-450 and Model SKE-450-ZN4 Engineering Specifications The system shall contain a voice evacuation system to supervise and operate UL listed voice evacuation speakers. The system shall have a built in UL listed power supply. The system shall be capable of supporting an optional UL listed zone splitter that can be housed in the main voice control cabinet. In addition, the system will issue pre-recorded voice commands locally for purpose of evacuation. The system must support a minimum of two pre-recorded messages and have the capability of adding application specific messages through the use of a PC. The voice evacuation system shall have the ability to provide a supervised microphone for the purpose of audible local instructions that will override the pre-recorded messages. The system shall contain a dead front panel inside the enclosure to protect the circuitry from tampering and to protect the operator from hazardous voltages. Specifications Speaker Wiring Operating Voltage: 120 Vrms @ 60Hz/ *230 Vrms @ 50Hz ("ask for HV version) Current Draw: Standby: 140 mA Alarm: 590 mA ZN4 Current Draw: ZN6 Current Draw Standby: 45 mA Standby: 35 mA Alarm: 250 mA Alarm: 120 mA (all channels) (all channels) Flush Mount Dotted Line is EOL Resistor return wires for i i and Solid Line Dimensions: Class(Style Z) ; is class B(style Y) Height: 24.75"(62.9 cm) Supervision Supervision Width: 14.5"(36.8 cm) ---� Depth: 3-7/16"(8.73 cm) with 5/8"protruding Overall Dimensions Command 2 Height: 26-3/8"(67 cm) Command 1 Width: 17-3/16"(43.66 cm) Wiring Wiring Total Depth: 4"(10.16 cm) � Operating Temp.: 32'to 120' F (0°to 49°C) " Humidity: 10 to 93% RH --- -- r s' Dotted Line is Class A EOL Resistor and (Style Z)Supervision Solid Line is for - Optional Accessories Class B(Style Y) SKE-V70 Module—Converts speaker circuit f Supervision voltage from 25 to 70.7 Vrms. Current Alarm ) Draw: Standby 10 mA;Alarm:70 mA. polarity shown , SKE-SRM—Supervised remote microphone. NAc Current Draw: Standby&Alarm: 30 mA. FACP SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350794 Rev B subject to change without notice. For more information, contact Silent Knight Copyright @ 2009 Honeywell International Inc by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com Honeywell ®SILENT' KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an - unacceptable level. Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. FEATURES & BENEFITS • New modern profile for • Dual LED design • Expanded color • Optional relay, improved aesthetics provides 360°viewing options isolator,and sounder • Stable communication angle . SEMS screws for bases technique with noise • Remote test feature wiring of the separate • Plugs into separate immunity from the panel base base for ease of • Low standby current • Built-in functional test installation and • Two-wire SLC switch activated by maintenance connection external magnet • Optional remote, • Built-in tamper- single-gang LED resistant feature accessory • Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. trim ring),white,10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of 3300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding low-profile mounting base. and trim ring),black,10-Pack. detector spacing,placement,and B501-WHITE:White,standard M02-04-01:Detector test magnet. special applications referto NFPA 72. European flan eless mounting base.UL p g g M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. RA100Z:Remote LED annunciator Guide,documentA05-1003,is available B501-BL:Black,standard European SMB600:Surface Mounting Kit at systemsensor.com flangeless mounting base.UL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacement trim ring for The SK-PHOTO-W Series flangeless mounting base.UL listed. B300-6,white. plug-in detectors use a separate base to B20OS-WH:White,Intelligent, TR300-IV:Replacementtrimring for simplify installation,service,and programmable sounder base. B300-6-IV,ivory. maintenance. Installation instructions B20OS-IV:Ivory,Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH:White,Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" 6200SR-IV:Ivory,Intelligent sounder (3.81 cm)deep. base for retrofit applications. NOTE: B20OS-LF-WH:White,Low Frequency •Because of the inherent supervision Intelligent,programmable sounder base. provided by the SLC loop,end-of-line resistors are not required.Wiring B200S-LF-IV:Ivory,Low Frequency "T-taps"or branches are permitted for Intelligent,programmable sounder Style 4(Class"B")wiring. base. B200SR-LF-WH:White,Low •When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory,plug-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector,remote test capable,for use B224BI-WH:White,plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white. B224BI-IV:Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base. detector with thermal sensing,white. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent www.sitentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel or trademarks of ENVIRONMENTAL Microsoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight°,System 6808:Addressable fire alarm control panel Sensor'and Honeywell' Photo:32°F to 122°F(0°C to 50°C) are registered 6700:Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal:32°F to 100°F(0°C to International,Inc. 38°C) 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel This document is not UL listed Velocity range:Photo/Photo with intended to be used for 5820XL:Addressable fire alarm control panel installation purposes.We Thermal:0 to 4,000 fpm(0 to 20 m/sec) tryto keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control information up-to panel with an emergency voices stem date and accurate.We Humidity:l0%to93%non-condensing p g y y cannotcover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 1350F(570C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed:S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved call800-446-6444. CS FM:7272-0559:0523 Operating Current C 24VDC:200µA(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA @ 24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd,CT 06472 Doc 3516341 Rev A 104/18 SILENT' 800-328-0103 ©2018 Honeywell International Inc. 0 KNIGHT SYSTEM SENSOR° L-Series Speakers and L-Series with LED � Speaker Strobes '''''" it��,���. _ ., ��`�� 111�i4 � , System Sensor L-Series and L-Series with LED audible visible notification products are rich with features , guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of speakers Digital Volt Meter(DVM)diagnostic test points for Speaker and speaker strobes in the industry with lower current draw and • Strobes modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela • Common aesthetics across the L Series platform range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 • Field-selectable candela settings on ceiling units: 15,30,75, Flexible design options meet virtually any application requirement: 95, 115, 150,and 177 wall or ceiling mount, red or white color choices, bezel kits for • Rotary switches for candela,speaker voltage(25 and 70.7 alternate markings and languages,and LED color lenses for Vrms)and power settings(1/4,1/2, 1,and 2 watts) distinctive visual signaling. In addition, installers can easily adapt • Mounting plate provides plug-in design for easier installation devices using field selectable candela,using rotary switches. and shorting springs to check wiring continuity The L-Series and L-Series with LED line is developed to simplify • Electrically compatible with legacy SpectrAlert,SpectrAlert installation.All devices feature plug-in designs with minimal intrusion Advance and L-series devices at 16-33 VDC into the back box,making installations fast and foolproof while • Synchronization through use of UL approved power supplies virtually eliminating costly and time-consuming ground faults.The that support System Sensor Sync protocol or System Sensor universal mounting plate includes an onboard shorting spring,so MDL Sync Module installers can test wiring continuity before the device is installed. • Speakers and Speaker strobes listed for wall or ceiling use • No extension ring required The low harmonic distortion of the speaker offers high fidelity sound • Speakers offer high fidelity and high volume sound output output while offering high volume sound output for use in high • 520 Hz capable with compatible Fire alarm control panel(FACP) ambient noise applications. In addition,the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without removing the appliance from the wall or ceiling.The DVM test points Agency Listings are discreetly located on the face of the notification appliance which SIGNALING enable faster troubleshooting and end of line(EOL)voltage checks while greatly reducing the risk of misplacing or damaging appliances C&US U� CLISTED°` FM during troubleshooting. LISTED LISTED APPROVED Speaker-Strobes: Speakers: Speakers: 3057383 7125-1653:0533 S4048 S4048 S4048 3057493 7135-1653:0532 7320-1653:0505 AVDS-62174:A•08/29/2024•Page 1 Product Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Power 1/4,1/2, 1,2 Watts Frequency Range 400 to 4000 Hz Maximum Supervisory Voltage(Speakers) 50 VDC Maximum Supervisory Voltage(Strobe) 33 VDC Strobe Flash Rate 1 Flash Per Second Nominal Voltages,Speakers 25 Volts or 70.7 Volts(nominal) Nominal Voltage,Strobe Regulated 24 VDC Operating Voltage Range,Strobe 16 to 33 VDC Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wall Speaker Strobes(including lens) 6.51 x 5.00" W x 2.3" D (165.1mm L x 127mm W x 58.4mm D) Wall Speaker Strobes(including lens)with SBBSPRUWL Surface 6.62"L x 5.12"W x 4.55"D(168.1 mm L x 130mm W x 115.5mm D) Mount Back Box Ceiling Speaker Strobes(including lens) 6.8"diameter x 2.33"D(172.7mm x 59.2mm) Ceiling Speaker Strobes(including lens)with SBBCRUWL Surface 6.9"diameter x 4.83"D(176mm x 122.7mm) Mount Back Box Wall SPL Speakers 6.51 x 5.00"W x 0.97"D(165.1 mm L x 127mm W x 23mm D) Wall Speakers with SBBSPRUWL Surface Mount Back Box 6.62"L x 5.12"W x 3.2"W(168.1mm x 130mm x 81.2mm) Ceiling SPC Speakers 6.8"diameter x 1.0"D(173mm x 25mm) Ceiling Speakers with SBBCRUWL Surface Mount Back Box 6.9"diameter x 3.5"D(176mm x 89mm) NOTE:SBBSPRUWL Surface Mount Back Box intended for speaker strobes and speakers. OutputMinimum Speaker Strobe Sound 1/4W 1/2W 1 W 2W UL Reverberant(dBA @10 ft) 76 79 82 83 UL Anechoic(dBA @10 ft) 76 79 82 83 Minimum Speaker Only Output 1/4 W 1/2 W 1 W 2 W UL Reverberant(dBA @10 ft) 79 82 85 88 UL Anechoic(dBA @10 ft) 79 82 85 88 UL/ULC Maximum Strobe Current Draw (mA) UUULC Max Strobe Current Draw Candela Rating 16 to 33 Volts DC 15 18 30 22 75 70 95 75 110 85 115 90 135 105 150 110 177 115 185 120 FCP" (future) "FCP Fire Control Panel,future use AVDS-62174:A•08/29/2024•Page 2 L-Series Dimensions 5.00 W'11 1d21 11271 0.97" 1.63" 6" (24.64 mm) (41.66 mm) (127 mm) p°00 0 A O O B e 8 A 00°p p000Ao eA0000 11 0000°0"O.oao°o0o° ° p ®® p °A0000°00000°00000° p 10 00p0°° °0p'00 00 °0®® Sg Oo080a08000B080B11 1 80 00 600 O00 0° 0°0® 0 OI OOBA001, 0 e o 0 0 007 °0 0°00°0 0° 1°°0 0°°e 0 °0®® °0 0°0°°°°°0°0°0°0°°°1 0° 0 0 0 0 0 0 0 0 0000000A0 0 6.5" oo A°oe0000e000ee0000e o0 0 0 0 0 0 0 o A ° s.so 00 os do 00 °® 0 OI 000010A1 0 AOOpe polo °® (166 mm) °o °°0°e°a°A°a°0°e°e°e o° 11 ss,1° °o°c o°o°o°° a°o°o°o ® °0 I o° °0°0 010°0°0°0°0 °e°o°e°e o° °o°o o°a°o°o°o°o °o°o°o om® °0 0°0°I°e°o°0°e°I°0°0 0° °0°0 0°p°o°o°0°0°0°0°0°0°0 0°0° °°0® 0o a0o0o0a0000$e0o0A0o 0o 0000 000000000000000000000 p0 OOo0o0000°000°000000000000 0"0000000 Op 00 1 0°0°0°0°0°0°0°0°0°0 80 o°0°0° °° °° °•°0°0°0 °° a�°20°°�0�0�°°0�°�a °0 °0° °000 °°0°0o°a°0.o°° 0 0 001.0. A0555-01 fl A0648-00 Wall-Mount Speaker Wall-Mount Speaker Strobe 2.33 6 [1%2] [41.61 fig"dla. 1.0" 1.63" (113 mm) (2fiA mm)) (41A mm) I Ceiling-Mount Speaker AO—_ Ceiling-Mount Speaker Strobe Ao__ L-Series with LED: Surface Mount Back Box ° ° t A0649-00 A0650-00 Wall-Mount Speaker Strobe with Ceiling-Mount Speaker Strobe with SBBSPSRUSBBSPWL Surface Mount Back Box SBBCRUSBCWL Surface Mount Back Box AVDS-62174:A a 08/29/2024 a Page 3 L-Series with LED: Ordering Information Model Description L-Series with LED Speaker Strobes SPSCRLED 2-WIRE,SPEAKER STROBE LED RED CEILING SPSCRLED-B 2-WIRE,SPEAKER STROBE LED RED CEILING BILINGUAL SPSCRLED-BT 2-WIRE,SPEAKER STROBE LED RED CEILING BILINGUAL WITH TRIM SPSCWLED 2-WIRE,SPEAKER STROBE LED WHITE CEILING SPSCWLED-B 2-WIRE,SPEAKER STROBE LED WHITE CEILING BILINGUAL SPSCWLED-BT 2-WIRE,SPEAKER STROBE LED WHITE CEILING BILINGUAL WITH TRIM SPSCWLED-T 2-WIRE,SPEAKER STROBE LED WHITE CEILING WITH TRIM SPSCWLED-TP 2-WIRE,SPEAKER STROBE LED WHITE CEILING PLAIN WITH TRIM SPSCWLED-CLR-ALERT 2-WIRE,SPEAKER STROBE LED WHITE CEILING ALERT CLEAR LENS SPSCWLED-P 2-WIRE,SPEAKER STROBE LED WHITE CEILING PLAIN SPSCWLED-SP 2-WIRE,SPEAKER STROBE LED WHITE CEILING FUEGO SPSRLED 2-WIRE,SPEAKER STROBE LED RED WALL SPSRLED-B 2-WIRE,SPEAKER STROBE LED RED WALL BILINGUAL SPSRLED-P 2-WIRE,SPEAKER STROBE LED RED WALL PLAIN SPSRLED-SP 2-WIRE,SPEAKER STROBE LED RED WALL FUEGO SPSWLED 2-WIRE,SPEAKER STROBE LED WHITE WALL SPSWLED-B 2-WIRE,SPEAKER STROBE LED WHITE WALL BILINGUAL SPSWLED-ALERT 2-WIRE,SPEAKER STROBE LED WHITE WALL ALERT AMBER LENS SPSWLED-CLR-ALERT 2-WIRE,SPEAKER STROBE LED WHITE WALL ALERT CLEAR LENS SPSWLED-P 2-WIRE,SPEAKER STROBE LED WHITE WALL PLAIN L-Series Speaker Description SPCWL 2-WIRE,SPEAKER RED CEILING SPCWL 2-WIRE,SPEAKER WHITE CEILING SPRL 2-WIRE,SPEAKER RED WALL SPWL 2-WIRE,SPEAKER WHITE WALL Accessories Description SBBSPWL BACK BOX,WALL,SPEAKER,RED SBBSPWL BACK BOX,WALL,SPEAKER,WHITE SBBCWL BACK BOX,CEILING,SPEAKER,RED SBBCWL BACK BOX,CEILING,SPEAKER,WHITE TR-2 TRIM RING,WALL,RED TR-2W TRIM RING,WALL,WHITE TRC-2 TRIM RING,CEILING,RED TRC-2W TRIM RING,CEILING,WHITE LED Lenses Description LENS-A3 Lens LED Amber Wall/Ceiling LENS-133 Lens LED Blue Wall/Ceiling LENS-G3 Lens LED Green Wall/Ceiling LENS-R3 Lens LED Red Wall/Ceiling Bezels Description BZSPR WALL RED BEZEL KIT BZSPW WALL WHITE BEZEL KIT BZSPWC CEILING RED BEZEL KIT BZSPWC CEILING WHITE BEZEL KIT Notes for Bezels: tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL(ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP(FUEGO), -SPE(FUEGO/FIRE) Bezels for use only with Speaker Strobes 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. �^ www.systemsensor.com 1 ©2024 System Sensor. STEM 3333 Unity Drive, Mississauga,ON 1-51-3S6 Canada Product specifications subject to change without notice.visit systemsensoccom SENSORS or current product information,including the latest version of this data sheet. Phone:800-SENSOR2•Fax:905-812-0771 AVDS-62174:A•OS/29/2024 www.systemsensor.ca SYSTEM SENSOR° Indoor Selectable- Output Strobes and 4*� Horn Strobes for Ceiling Applications f System Sensor L-Series audible visible notification r products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M X APPROVED LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current • Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn and Horn Output 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 L-Series Dimensions 2.47 6.83 1.37 �6.92 � �2.50 •ow*►.un O SPu TR O O s O o CDo O ® O O O o Q o 0 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box c �Pp�P�\Ni ®® o®mmmoo OOS�oo®®�mmo�00p 0 ® 9501 o �OOoO 0 OOO0000 0 0 Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White SYSTEM ©to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensoccom or current productinformatiSudingthelatestversionofthisdaasheet. SENSOR Phone:800-SENSOR2•Fax:630-377-6495 AVD8 AVDS6801•03/17 SYSTEM SENSOR° F I I I I F �_IlilI I Indoor Selectablem Output Horns, E •� �� E w Strobes and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification - products are rich with features guaranteed to cut - ;;_, installation times and maximize profits with lower 1 current draw and modern aesthetics. } '� Features _ r • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M ® APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 L-Series Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'M Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(rnA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Strobe,UL Max.Current Draw(rnA RMS),2-Wire Horn 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.11K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 .Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 1.91 3.46 3.46 1.25 1.25 0°0 000000 0a0 0 0 0 0 0 1 00000000000 aa0000 0 0 0 0 a 0 oaQQQaQQQaoao 0000000000000 p000000000000 5.27 5.27 0000000, �I 00000aooa000° aaoaoaoaoaoao 000a000000000 0000000000000 Q .0.0.QQQQQLQ 0 0 Compact Strobe/Horn Strobe Compact Horn 4.70 1.91 4.70 1.25 1.25 ..QQQQQ a Qa 5.67 .67 QQQQQQQ4QQ QhQQ444 Qh4'Qh4 4!Q!Q!Q5 Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT'marking on cover SYSTEM3825 Ohio Avenue•St.Charles, IL 60174 ©2017 System Sensor. SENSOR" Phone:800 SENSOR2•Fax:630 377 6495 Product rcurre current product sumatioct o change without estive.VisitfthisdatashWom for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS86503.03/17 SYSTEM -� SENSOR° Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products CA 64 are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill () holes for screw-in mounting. Plastic and metal weatherproof back O boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED F M :0:MEA 7300 1653:187(outdoor strobes) approved 7125-1653:188(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S4011(chimes,horn strobes,horns) APPROVED pp chime strobes) S3593(outdoor and alert strobes) 3N,'F7� MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitT"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with •8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic OutputStrobe Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams 11 4.7" 11 4 2.5" 5.6" O 0 Wall-Mount Horn Strobes ® ® Wall Plastic Weatherproof Back Box UP Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description 1 Wall Horn Strobes P2RK`t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK`t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK•t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK't Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: Add '-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Produc specifications subject02SysmSentnotice.Visit systemsensoccom SENSOR Phone:800-SENSOR2•Fax:630-377-6495 or current product information,ind1201 he latest version ofthis data sheet. AVDS01201•3/12 FIRE ALARM PERMIT APPLICATION For Instruction/Checklist,please click here Site Address: 18725 67TH AVE NE Project Name: I IRONWOOD DAYCARE TI Project Valuation: 6515.00 Preferred Contact: O Owner OO Contractor Project Description: FIRE ALARM ALTERATIONS FOR TENANT IMPROVEMENT Owner Details Owner Name: GRANDVIEW Office No.: Email Address: GV@GRANDVIEWINC.NET Cell No.: Mailing Address: PO BOX 159 City: ARLINGTON State: I WA Zip: 98223 Contractor Details Contractor Name: I B&H FIRE AND SECURITY Office No.: 360-322-7634 Email Address: HAILEY@BNHFIRE.COM Cell No.: 360-322-7634 Mailing Address: PO BOX 3711 City: ARLINGTON State: I WA Zip: 98223 L&I Contractor License Number: I BHFIRHF842KW Expiration Date: 05/16/2026 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application—review and approval required TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal lto2 $ 75.00 = $0 3 to 5 $ 125.00 = $Q 6to 10 $ 175.00 = $0 11 to 20 $ 225.00 = $ 21 to 40 $300.00 = $ 300 41 to 100 IF $375.00 11 = $Q 101 to 200 $475.00 =F = $Q >200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices=[22 $500.00 + $ _ $ FACP/TRANSMITTER ModificationIF— $125.00 = $ PERMIT FEE SUBTOTALIF $ iwoo, O NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $ 350.00 = $ 101 to 200 IF $ 475.00 = $ L==, >200 $500.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200 = $ PERMIT FEE SUBTOTAL IF = $ E Plan review fee due at time of submittal TOTAL PERMIT FEE $ 300 PLAN REVIEW FEE $U Processing/Technology Fee $ 25.00 TOTAL $ 325 I hereby certify that I am the Owner OApplicant Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Print Name: HAILEY BROSSARD Date: 02/16/2026 4rtk( tot( WASHINGTON Permit Information - - , 1 'nformat;^ Permit# 26-0158 Parcel # 31052300200500 Building ID Location 18725 67TH AVE NE Permit Type Fire Permit Use Fire Alarm Zone Permit # Subdivision Applicant Name jeff brossard Address PO Box 3711 ARLINGTON Applicant Email jeff@bnhfire.com Phone 3603227634 Cell Owner Name GRANDVIEW Address PO BOX 159 Owner Email GV@GRANDVIEWINC.NET Phone Cell Contractor B+H Fire and Security Address PO Box 3711,Arlington, WA 98223 Contractor Email jeff@bnhfire.com Phone 360-322-7634 Cell Property Information Type/Improveme Accessory/Struct nt ure Current Use Proposed Use Current Zoning 0 Proposed Zoning Project Cost 6515 Project Value 6515 Current Use And FIRE ALARM ALTERATIONS FOR TENANT IMPROVEMENT Proposed Changes Lot Width Lot Depth Map Number Total Area of Building & Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions/ Variances @ Community Development Online Portal Page 1 of 6 July 17, 2026 02:17PM WASHINGTON Structure Information Structure Type # of Stories Usable Floor Area (Sq Ft) Structure Height # of Units Load per Floor (Lbs) Sign Dimensions # of Bedrooms # of Bathrooms Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth Material Foundation Information Setbacks Front& 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width # of Off Street # of Off Street Parking Loading Miscellaneous Information ©Community Development Online Portal Page 2 of 6 July 17, 2026 02:17PM WASHINGTON Contractors License# Business Name Type Contact BHFIRHF842KW B+H Fire and Security General Jeff Brossard ©Community Development Online Portal Page 3 of 6 July 17,2026 02:17PM WASHINGTON Inspections Inspection # Inspection Type Status Date Inspector 26-0252 Fire- Fire Alarm Final Pass April 24, 2026 Steve Goforth ©Community Development Online Portal Page 4 of 6 July 17,2026 02:17PM 4rtk( tot( WASHINGTON Contacts Contact Name Type Project Address Phone GRANDVIEW Owner PO BOX 159 jeff brossard Others PO Box 3711 ARLINGTON 360-322-7634 jeff brossard Applicant PO Box 3711 ARLINGTON 360-322-7634 ©Community Development Online Portal Page 5 of 6 July 17, 2026 02:17PM 4rtk( tot( WASHINGTON Fees Fee Type Date Debit Credit Balance Permit Fees February 17, 2026 $525.00 $525.00 $200.00 $325.00 $325.00 $0.00 T O T A L $525.00 $525.00 $0.00 ©Community Development Online Portal Page 6 of 6 July 17, 2026 02:17PM TY O City of Arlington 18204 59th Avenue NE, Arlington, • • 1114r(" too Washington 98223 Phone: 360-403-3551 1 G,�0 WASHINGTON N Invoice Number: 26-0155 INVOICE Invoice Date: February 17, 2026 Account Number: 141615055 Bill To: Invoice Questions? jeff brossard Phone: 360-403-3551 PO Box 3711 ARLINGTON Email: ced@arlingtonwa.gov Invoice Due Date: February 17, 2026 Record Number: Permit A26-0158 Parcel Number: 31052300200500 Location: 18725 67TH AVE NE Date Description Paid Date Amount Paid Balance February 17, Fire System Plan Review(006.345.83.00.02) $200.00 2026 TOTAL: Permit Fees $200.00 $200.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by February 17, 2026 Number Number This Invoice 26-0155 141615055 1$200.00 jeff brossard PO Box 3711 ARLINGTON City of Arlington 14 (11 (0/1 18204 59th Avenue NE, Arlington, • • Washington 98223 Phone: 360-403-3551 jNG� WASHINGTON C Invoice Number: 26-0239 INVOICE Invoice Date: March 10, 2026 Account Number: 141615055 Bill To: Invoice Questions? jeff brossard Phone: 360-403-3551 PO Box 3711 ARLINGTON Email: ced@arlingtonwa.gov Invoice Due Date: March 10, 2026 Record Number: Permit A26-0158 Parcel Number: 31052300200500 Location: 18725 67TH AVE NE Date Description Paid Date Amount Paid Balance February 17, Processing/Technology(320.341.43.00.02) $25.00 2026 February 17, Fire Alarm System Permit(006.322.10.00.01) $300.00 2026 TOTAL: Permit Fees $325.00 $325.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by March 10, 2026 Number Number This Invoice 26-0239 141615055 1$325.00 jeff brossard PO Box 3711 ARLINGTON WASHINGTON Permit #26-0158 Location:18725 67TH AVE NE Routing Details ✓ Department: Permit Tech Intake Review - Approved: March 10, 2026 - Status: Approved Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at February 17, 2026 03:02PM Status: Pending Activity Type: Pending Payment Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE - by Admin - Hannah Hardwick- Fire Permit Technician II at February 23, 2026 02:22PM Status: Pending Activity Type: Pending Payment Hello, Your invoice for the plan review fee is now ready for payment. You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II @ Community Development Online Portal Page 1 of 6 July 17, 2026 02:18PM lirttf tot( hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at February 23, 2026 02:23PM Status: Pending Activity Type: Pending Payment Hello, Your invoice for the plan review fee is now ready for payment. You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at March 6, 2026 01:57PM Status: Pending Activity Type: Pending Payment Hello, Your invoice for the plan review fee is now ready for payment. Plan review fees are due at time of submittal and prior to processing for review. You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov ©Community Development Online Portal Page 2 of 6 July 17, 2026 02:18PM WASHINGTON 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at March 9, 2026 02:53PM Status: In Progress Activity Type: In Review Application is ready for review. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at March 10, 2026 09:49AM Status: Approved Activity Type: Application Sent Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 ✓ Department: 1st Review Building - Approved: March 9, 2026 - Status: Approved Permit Application #A26-0158 Location:18725 67TH AVE NE- by Kevin Olander- Building Official at March 9, 2026 03:19PM Status: Approved Activity Type: Application Sent Kevin Olander City of Arlington Building Official kolander@arlingtonwa.gov 3604033433 ✓ Department: 1st Review Fire - Approved: March 10, 2026 - Status: Approved Permit Application #A26-0158 Location:18725 67TH AVE NE- by Steve Goforth -Assistant Chief/Community Risk Reduction at March 10, 2026 08:29AM Status: Approved Activity Type: Application Sent NCRFA Approved Steve Goforth North County Regional Fire Authority Assistant Chief/Community Risk Reduction @ Community Development Online Portal Page 3 of 6 July 17, 2026 02:18PM liptiot tot( WASHINGTON sgoforth@northcountyfireems.com 360-629-2184 ✓ Department: Permit Tech Final Approval - Approved: March 20, 2026 - Status: Approved Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at March 10, 2026 09:52AM Status: Pending Activity Type: Pending Payment Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment and I'll provide a copy of your issued permit and approved documents. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician 11 at March 16, 2026 01:31PM Status: Pending Activity Type: Pending Payment Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment and I'll provide a copy of your issued permit and approved documents. Admin - Hannah Hardwick @ Community Development Online Portal Page 4 of 6 July 17, 2026 02:18PM 4rtk( tot( WASHINGTON City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0158 Location:18725 67TH AVE NE- by Admin - Hannah Hardwick- Fire Permit Technician II at March 20, 2026 02:27PM Status: Approved Activity Type: Permit Issued Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit #26-0158 Location:18725 67TH AVE NE - by Admin - Hannah Hardwick- Fire Permit Technician II at March 20, 2026 02:28PM Status: Approved Activity Type: Permit Issued Hello, Please find attached the issued building permit. Please review any conditions and reach out should you have any questions. Inspection request instructions can be found on the permit. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 @ Community Development Online Portal Page 5 of 6 July 17, 2026 02:18PM WASHINGTON Record Actions New Permit Application #A26-0158 Location: 18725 67TH AVE NE By Katy Shores- Engineering Admin Specialist III at February 17, 2026 08:56AM Hello, A new permit application has been submitted for review. Please login to your CIVICGov Web Application account and visit the link below to view the permit details. https://www.civicgov4.com/wa_arlington/permits/details/286 If you cannot click on the link above, please copy and paste the entire link in the browser address bar. Sincerely, CIVICGov Team. Condition #1 Added By Admin - Hannah Hardwick- Fire Permit Technician II at March 20, 2026 02:22PM Condition: Adhere to approved plans. Condition #2 Added By Admin - Hannah Hardwick- Fire Permit Technician II at March 20, 2026 02:23PM Condition: Permit shall be onsite for inspections. Condition #3 Added By Admin - Hannah Hardwick- Fire Permit Technician II at March 20, 2026 02:23PM Condition: Call for inspections. Inspection #26-0252: Result- Pass By Kevin Olander- Building Official at April 27, 2026 12:08PM Fire - Fire Alarm Final Inspection #26-0252: Result- Pass FIRE ALARM FIRE FINAL FOR IRONWOOD DAYCARE. PLEASE CALL TO CONFIRM DATE AND TIME SO WE CAN LET APARTMENT MANAGER KNOW, SO TENANTS CAN BE NOTIFIED. ©Community Development Online Portal Page 6 of 6 July 17, 2026 02:18PM 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Fire - Fire Alarm Permit Parcel:31052300200500 Permit#:26-0158 Permit Address:18725 67TH AVE NE Date Issued:March 20,2026 Description of Work:FIRE ALARM ALTERATIONS PERMIT EXPIRES 180 DAYS FOR TENANT IMPROVEMENT AFTER DATE OF ISSUANCE. Valuation:$6515 Code Year: OWNER APPLICANT CONTRACTOR GRANDVIEW jeff brossard B+H Fire and Security PO BOX 159 PO Box 3711 ARLINGTON PO Box 3711,Arlington,WA 98223 3603227634 360-322-7634 GV@GRANDVIEWINC.NET jeff@bnhfire.com jeff@bnhfire.com registration_number:BHFIRHF842KW PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved plans. 2.) Permit shall be onsite for inspections. 3.) Call for inspections. INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance February 17, Processing/Technology(320.341.43.00.02) $25.00 2026 February 17, Fire System Plan Review(006.345.83.00.02) $200.00 2026 February 17, Fire Alarm System Permit(006.322.10.00.01) $300.00 2026 TOTAL: Permit Fees $525.00 $525.00 Credit/Debit Card 324 Payment Successful March 6, 2026 $200.00 $325.00 Credit/Debit Card 408 Payment Successful March 17, 2026 $325.00 $0.00 N m3a 1 Z=N 0LLLa mZm Oac c.i= aa�a I B I (E)A U 15td a IU _ B BREAK ROOM ROOM 5 B r a° O t5cd I REST � ROOM Ism txd I B ® ® ° Eon B 00 ® ® DESIGNER: NICET LEVEL 33 ID#R1148093 / KITCHEN LICENSE: B °," ;o, 15cd 0` BROSSJB9511-7 REFERENCE: ROOM 4 / E7)Scd EOL ❑ — J 75ca 2021 IFC AND 2019 NFPA 72 / ° •o; _ lsaa C .o. e ❑ 2 I HB1 CKT 5 (714 / ~ M W N i� z 00 m F B ROOM 3 B B Q W Z / A U o 75cd / ❑ W 0 0 c; 0 Q _ IB V 1xd 15cd O Lo 15cd .o. ;o; REST B �— (R) H ROOM It O 0 (R) 0 2 B A ) - 7 Z t5cd Z � O LOBBY (R) REST A A —— OFFICE ROOM D�� B I 0 ° �) Q = ~ 15cd r d D-d o -1sctl EVAC FEED - e 15cd B ROOM 2 / ,o e ISSUES I / •(R) REV DATE DESCRIPTION 75cd / ROOM 1 / REST PACKAGE ROOM ROOM o•C / D 0 HB1 CKT 1 HB1 CKT 7 B (R) A J D \ 7 TO FACP ❑ TITLE: HB1 CKT 6 \ \ n �2 FIRE ALARM O R RISER PLAN (E) 0 1xe �l(E) ROOM d_ EOL Bwp 4' X 8 DATE: € DECEMBER 6,2025 PROJECT NO.: R L 25-039 SHEET: a 1 FIRE ALARM PLAN `eV SCALE:B/W=1-0-' FA- y � 0 4' 8' 12' o a D SCALE: 3/16"=1'-O" N Approved >m 3 a r I>N V V CJ Steve Goforth, Fire Marshal m o o(D"a Subject to Field Review q Lj 03/10/2026 8:27:14 AM a v- EQUIPMENT LEGEND DEVICE EVAC FEED SYMBOL QUANTITY PART NUMBER DESCRIPTION BACKBOX /-y^7 r 15cd 15cd �d 15cd EXISTING SILENT KNIGHT FIRE ALARM H81 CKT 7 FRCP (E) 6808 INCLUDED ;o; ;o; ;o; ;o; CONTROL PANEL (E) C — — — D� DESIGNER: B — — —�— HBt 1 PS SILENT KNIGHT HORN BOOSTER INCLUDED JEFF BROSSARD 75cd 75cd 15cd \ lkd 15cd 15cd HB1 CKT 6 15cd 15cd EVAC 1 SKE-450 SILENT KNIGHT VOICE EVACUATION NICET LEVEL 3 ID#148093 ;O; ;O; ;O; 'O I'd, ;O; ;O ;O; EOL SYSTEM LICENSE: C C B = O 4 SK-PHOTO-W SILENT KNIGHT SMOKE DETECTOR 4 SQUARE X 1-7/8"DEEP BROSSJB951L7 75cd 75cd REFERENCE: HB1 CKT 5 75cd 15cd 75cd EOL E N 4 SWLED SPECTRA ALERT MOUNT 4 SQUARE X 1-7/8"DEEP C C;o; ;o; ;o; 2021 IFC AND 2019 NFPA 72 e EOL P20 7 P2WLED SPECTRA ALERT WALL MOUNT 4 SQUARE X 1-7/8"DEEP HORN STROBE HB1 CKT 1 75cd ,"Wp 75cd 75cd EDON 5 SPSWLED SPECTRA ALERT CEILING MOUNT 4 SQUARE X 1-7/8"DEEP HORN STROBE 2 2 2 2 D� N SPECTRA ALERT WALL MOUNT LOW A e = C 5 SPSCWLED FREQUENCY SOUNDER STROBE 4 SQUARE X 1-7/8"DEEP TO 120 VAC UNSWITCHED DEDICATED CIRCUIT ------ e o N TO TELCO ROOM FACP(E) H61 EVAC ,y 1 EXISTING WEATHERPROOF HORN STROBE -- CIO B (•) PROVIDED AND INSTALLED BY OTHERS W N FIRST FLOOR w 00 Vim/ --------- EXISTING DEVICE TO REMAIN z NEW OR EXISTING DEVICE RELOCATED ` w z FIRE ALARM ONE-LINE RISER DIAGRAM NINDICATES CANDELA z O SCALE:NONE (E) INDICATES EXISTING w (R) INDICATES EXISTING DEVICE RELOCATED OR REMOVED Q Q z C INDICATES CEILING MOUNT 00 EOL— END OF LINE RESISTOR Q �/�-� 0 \Y 0 Lo SEQUENCE OF OPERATIONS DESIGNED AUDIBILITY LEVEL PER WIRE LEGEND (V O OCCUPANCY CLASSIFICATION IM` F-- w r F u Z GROUP A 70db TYPE DESCRIPTION 7 V c c ¢ 'FP L rl ° z A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE 0 0 z GROUP B 70db O J z za ' �0 u o a > >u z� J� o �z zz 0 02 a O O B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE O Ei N ¢N a z F v+F GROUP E 60db Q z a a s m Z 3: 'z �_ GROUP F 95db z C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE vi w z z�w m ¢z �O mI >I 0 0 0 0 E5 0 w r D 16 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE z'u z w ¢o g¢ °z w z GROUP M 55db aLLv�iu WATERFLOW DEVICE X X X X GROUP R 50db GENERAL NOTES: TAMPER DEVICE X X X GROUP S 45db 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. ISSUES 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO REv DATE DESCRIPTION BUILDING PULL STATION X X X X BE IN CONDUIT. BUILDING SMOKE DETECTOR X X X X 3. ALL JUNCTION BOXES, COVERS,AND BACK BOXES ARE TO BE PAINTED RED. AC POWER LOSS X X X 4. PULL STATIONS ARE TO BE MOUNTED AT 42"TO 48"ABOVE THE FLOOR. LOW BATTERY X X X 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES,AND SPEAKER STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6"BELOW THE CEILING, WHICHEVER IS LOWER. TITLE: 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: FIRE ALARM A) 36"INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES LEGENDS, NOTES 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING,AS HIGH AND RISER AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. DIAGRAM x 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. 8 DATE: DECEMBER 6,2025 i i PROJECT NO.: R 25-039 SHEET: a FA-2