HomeMy WebLinkAbout18304 Cedarbough Loop_P26-0266_2026 • FIRE SPRINKLER PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 Type of Permit: ✓❑ New Installation ❑ System Modification ❑ Phased Installation Property Address. 18304 Cedarbought Lp Project Valuation: $11,000 Lot#: 3140 parcel ID No.: 738500402400 Preferred Contact: ❑Owner ElApplicant ❑Contractor Project Description: Installation of a new NFPA 13D sprinkler system composed primarily of CPVC pipe and fittings.20 sprinkler heads total. Owner Name: Weikianos Dessalgn Phone No.: (206) 596-1779 Email Address: Weikidessalgn@gmail.com Cell No.: (206) 596-1779 Mailing Address: 18304 Cedarbought Lp City: Arlington State: WA Zip: 98223 Applicant Name: Ira Potter Phone No.: (253) 576-2314 Email Address: ipotter@ravenfp.com Cell No.: (235) 576-2314 Mailing Address: 3204 Crystal Ridge Dr City: Puyallup State: WA Zip: 98372 Contractor Name: Raven Fire Protection Office No.: 253-387-1090 Email Address: ipotter@ravenfp.com Cell No.: 253-576-2314 Mailing Address: 3204 Crystal Ridge Dr SE City: Puyallup State: WA zip:98372 L&I Contractor License Number: RAVENFP750-PN Expiration Date: 10/15/2027 SUBMITTAL REQUIREMENTS:Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: El Complete and Scaled Plans El Hydraulic Calculations ❑ Equipment Specifications for Each Fire Sprinkler Permit Application ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers,Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $12,000.00 = $200.00 $12,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV2.2026 Page 1 of 3 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.Oa + 1 $ 1 = $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ❑ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $625.Oo + I I = $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ✓❑ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $175 11 to 25 $225.00 = $ 26 + $275.00 = $ -NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ 175 Page 2 of 3 HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I - new or existing x $150.00 = $ Class II - new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE:SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time ofsubmittal TOTAL PERMIT FEE $175 PLAN REVIEW FEE $200 Processing/Technology Fee $25.00 TOTAL $400 I hereby certify that I am the DOwner, DApplicant, ✓Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Digitally signed by Ira Potter Ira Potter DN C=US E=iLLC, U=Patne Rave n Ira Potter 4/6/26 Fire Protection LLC,OU=Partner,CN=Ira Potter Date:2026.04.06 17:38:03-07'00' Signature Print Name Date SAVE PRINT Page 3 of 3 f....w................... —q 1 Expires WASHINGTON STATE piree DE 6 CERTIFICATE OF COMPETENCY FIRE SPRINKLER SYSTEMS Christine Cheryl Pleasant ; 1 7662-0126-C Level 1 Raven Fire Protection 1 RAVENFP750PN j 1 1 1 1 - 04/04/2026 j signature Date City of Arlington Building Department APPROVED Kevin Olander- 04/30/2026 No changes authorized unless approved by the Building Official Hydraulic Calculations by HydraCALC Raven Fire Protection 3204 Crystal Dr. SE Puyallup, WA 98372 (253) 387-1090 Job Name Weikainos Adult Family Home Drawing FP-002 Location 18304 Cedarbough Lp Arlington, WA 98223 Remote Area 1 Contract 10-0015 Data File Weikainos (AFH) Calc.WXF Computer Programs by Hydratec Inc. Revision: 50.5520.727 Raven Fire Protection Page 1 Weikainos Adult Family Home Date 04/04/2026 HYDRAULIC CALCULATIONS for JOB NAME Weikainos Adult Family Home Location 18304 Cedarbough Lp Arlington, WA 98223 Drawing# FP-002 Contract# 10-0015 Date 04/04/2026 DESIGN Remote area# 1 Remote area location Bedroom E & F Occupancy classification Residential Density .05 - Gpm/SgFt Area of application 238.2 -SgFt Coverage/sprinkler 256 -SgFt Type of sprinkler calculated Residenial Concealed Pendent #Sprinklers calculated 2 In-rack demand - GPM Hose streams 0 - GPM Total water required(including hose streams) 25.9758 - GPM @ 21.3159 - Psi Type of system Wet Volume of system (dry or pre-action) - Gal WATER SUPPLY INFORMATION Test date Location Source of info Pump and Tank CONTRACTOR INFO Raven Fire Protection Address 3204 Crystal Dr. SE/ Puyallup, WA 98372 Phone# (253) 387-1090 Name of designer Authority having jurisdiction NOTES: Water Supply-Talco Home Hydrant HH3-150SP Residential Fire Pump and Tank See Submittal Data textl(35) - invisible Computer Programs by Hydratec Inc. Revision: 50.5520.727 Water Supply Curve Raven Fire Protection Page 2 Weikainos Adult Family Home Date 04/04/2026 Pump Data: Demand: P1 - Pump Churn Pressure 55 D1 - Elevation 2.130 P2- Pump Rated Pressure 51 D2- System Flow : 25.976 P2- Pump Rated Flow 25 D2- System Pressure 21.316 P3- Pump Pressure @ Max Flow 40 Hose ( Demand ) P3- Pump Max Flow 50 D3- System Demand : 25.976 Safety Margin 29.419 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 2 E 50 P3 40 30 2 20 10 10 20 30 40 50 60 70 80 90 FLOWN ^ 1.85 ) Computer Programs by Hydratec Inc. Revision: 50.5520.727 Fittings Used Summary Raven Fire Protection Page 3 Weikainos Adult Family Home Date 04/04/2026 Fitting Legend Abbrev. Name '/2 3/4 1 1'/4 1'/2 2 2'/2 3 3'/2 4 5 6 8 10 12 14 16 18 20 24 Ball B Ball Milw BB-SC100 2.25 2 2.5 2.25 10 N* CPVC 90'EII 0 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Branch Tee 0 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.5520.727 Flow Summary - NFPA Raven Fire Protection Page 4 Weikainos Adult Family Home Date 04/04/2026 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure PUMP See Information on Pump Curve 50.735 25.98 21.316 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H 1 8.917 4.9 7.0 12.96 0.05 256 H2 8.917 4.9 7.05 13.01 0.05 256 101 9.583 7.07 102 9.583 11.95 103 8.583 18.87 PUMP 4.0 21.32 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations : Hazen-Williams Raven Fire Protection Page 5 Weikainos Adult Family Home Date 04/04/2026 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf H 1 8.917 4.90 12.96 1 N 5.0 1.750 150 7.000 to 0 5.0 10.000 -0.288 101 9.583 12.96 1.101 11.750 0.0305 0.358 Vel = 4.37 0.0 101 12.96 7.070 K Factor= 4.87 H2 8.917 4.90 13.01 1 N 5.0 5.000 150 7.051 to 5.000 -0.288 101 9.583 13.01 1.101 10.000 0.0307 0.307 Vel = 4.38 101 9.583 12.97 1 20 10.0 34.250 150 7.070 to 10.000 0.0 102 9.583 25.98 1.101 44.250 0.1104 4.884 Vel = 8.75 102 9.583 0.0 1 0 5.0 43.750 150 11.954 to 2N 10.0 15.000 0.433 103 8.583 25.98 1.101 58.750 0.1103 6.483 Vel = 8.75 103 8.583 0.0 1.25 Ball 3.174 10.000 150 18.870 to 3.174 1.985 PUMP 4 25.98 1.394 13.174 0.0350 0.461 Vel = 5.46 0.0 PUMP 25.98 21.316 K Factor= 5.63 Computer Programs by Hydratec Inc. Revision: 50.5520.727 NOTE: SCOPE OF WORK: SPRAY FOAM INSULATION 2 x DIAMETER OF THE RA CREWS 1/3 DEPTH E N SHALL HAVE NO CONTACT FOUR#10 x 1%" LARGEST HOLE(MINIMUM) THIS PROJECT WILL CONSIST OF THE INSTALLATION OF A NEW RESIDENTIAL ROOF SHEATHING WITH CPVC PIPING. SHEET METAL SPRINKLER SYSTEM.POINT OF CONNECTION WILL BEAT THE DISCHARGE VALVE OF S ———— ALLOWED HOLE ZONE THE TALCO HH3 TANK/PUMP SYSTEM, EXCLUSIONS: FIRE PROTECTION FIG.511 — — HANGER I PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT 2"PIPE, MAXIMUM ELECTRICAL WIRING OF ANY KIND,INC LUDING BUT NOT LIMITED TO WATER FLOW 3204 Crystal Ridge Dr SE SWITCH,ELECTRIC BELL,AND TAMPER SWITCH / Puyallup,WA 98372 CENTRALSTATION MONITORING EQUIPMENT,WIRING AND SERVICES 2xDIAMETERMI THE Phone:253-387-109 7-1090 CPVC PIPING LVLAND PSL LARGEST HOLE(MINIMUM) ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO:BACKFILL,SELECT FILL, BATT INSULATION INSTALLATION REQUIREMENTS:STAPLE LSL HOLE ZONE HOLEZONE 1/3 DEPTH BREAKING PATCHING,SAW CUTTING,LAWN REPAIR,LANDSCAPING,TREE REMOVAL, www.ravenfp.com BATTS A MINIMUM OF EVERY SIN.WHERE JOISTWIDTHS / STERILIZATION,DEVELOPMENT FEES AND CITY CONNECTION. LIC#RAVENFP750PN EXCEED Fr.,EXTEND INSULATION 2 FT ON BOTH SIDES O THE WATER-FILLED PIPE.EXTEND INSULATION 6 IN.FROM ROOF RAFTERS CLOSED CELL SPRAY FOAM ROOF RAFTERS d —— —— GENERAL NOTES: —— —— THE ENDS OF THE WATER-FILLED PIPE.WHERE MULTIPLE INSULATION ABOVE CPVC PIPING ' 1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. LAYERS OF BATT INSULATION ARE INSTALLED,IT IS MOST .............................. EFFECTIVE TO CROSS-LINK BATTS TO COVER GAPS. LVLAND PSL w�axlMurox ar-T AL OWED HOLEZ NE 2. HEATTO BE PROVIDED BYTHE OWNER ATALLTIMES FOR WET TYPE SPRINKLER eexrlFle�reoFCOMFere d A SYSTEMS. ' FIRE a.IRKLERa TEMSRC LSL ALLOWED HOLE ZONE 3. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIREPROTECTION SYSTEM AT CLOSED CELL INSULATION AT ROOF CPVC,STEEL-HANGER FIG.511 ALLOWED HOLE ZONE OR ANY APEDKEENANCESTHEREOF. ��a"•""np s m� ATTIC INSULATION DETAIL NI i 4. ALL PI PE TO BE CPVC U.N.O. ---�5 0a/0412026 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 5554.FT.AND LESS �.......�..'r ..........R"'.....i (NFPA 13D 2019 8.3.2). FIG.514 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, HANGER AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: (2) 'HEX HANGERS-PIPE HANGERS SHALL BE SIZED,SPACED AND INSTALLED 1 THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ FT TRUSS BTM CHORD HEADSCREWS AS ) UNFACED REQUIRED BY NFPA STANDARDS. 2)THE WALLS AND CEILING ARE SURFACED WITH NONCOMBUSTIBLE OR FIBERGLASS -NO OTHER PIPING ANDIOR DEVICES ARE TO BE ATTACHED TO THE LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN EPA 220.(NFPA 13D 2019) BATT INSULATION SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN PIPE BACKING NUT 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES, FIG.29 _ SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. CARPORTS,AND SIMILAR STRUCTURES.(NFPA 13D 2019) HANGER� 1 -THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. PENTHOUSE EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED •'•� -SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT USED FOR THIS INSTALLATION. VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS,CRAWL CPVC PIPE \ NFPA 13(2010)TABLE 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED (2)5l16"HEX \LX (R-In) FOR LIVING PURPOSES.(NFPA 13D 2019) HEADSCREWS 9. SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS(REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR ACCESSED FROM OUTDOORS WHERE THE PIPE TYPE NOMINAL PIPE SIZE(IN-) CLOSETDOES NOT HAVE A DOOR OR UNPROTECTED PENETRATIONS DIRECTLY PIPE \ INTO THE DWELLING UNIT.(NFPA 13D 2019) J/BTM CHORD OF TRUSS CPVC 1 1/ 1A 2 2% 3 5-6 6-0 6-6 7-0 5-0 9-0 10-0 10. AMAIN DRAIN ISTO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH (2)5116"HEX (2)5/16"HEX NFPA 13D 2019.HUB-DRAINS TO BE PROVIDED BV OTHERS AS NEEDED. HEADSCREWS HEADSCREWS 11, NO GYP,BD.CEILINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL TENTING OVER CPVC PIPING EATON INSPECTION IS COMPLETE. CPVC,STEEL-HANGER FIG 29 CPVC,STEEL-HANGER FIG.514 PIPE HANGERS SPACING 12. MAXIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 16'X16'.MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14'X14'.MAXIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 16'X20'.U.N.O. INSTALLATION AND HANGER DETAILS 13, MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-DO.C.MINIMUM DRY SIDEWALL SPRINKLER SPACING 6-OO.C'.MINIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 8-OO.C. 14. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D 2019 15. PIPE SHALL BE REQUIRED TO REMAIN ON A 2/,"CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES, 16. IT5.6.1)SPRINKLERS INSTALLED WHERE MAXIMUM AMBIENT CEILING TEMPERATURES DO NOT EXCEED 100 DEGREES FAHRENHEIT SHALL BE ORDINARY TEMPERATURE-RATED OF INTERMEDIATE TEMPERATURE RATED SPRINKLERS THROUGHOUT UNLESS MODIFIED BY REQUIREMENTS OF 7.5.6.3 WATER SUPPLY INFORMATION: WATER SUPPLY INFORMATION IS PER PUMP AND TANK MANUFACTURER DATA ATALCO FIRE SYSTEMS (E)BEDROOM B CL (E)BEDROOM C (E)LIVING W&D HALL (N)BEDROOM D HOME HYDRANT HH3-150SP 2 ® 350 Gallon Water Tank ill�sor 1)Tank D2in�"(OHT) _ Iq ewtt ®OverRow Fitting 1"(FNPT) Q3 Auto-Fill Valve a"(FNPT ® Revisions 1.51HP Electric Motor 240 Volt Single-Phase 10.9 Amp(Full Load) -(b BUILDING SECTION"A" 114"=1'-0e Smartlftlserr11(Fo Sys mm 77 © Contract Name: (44)Isolation Bell Valve I o Weikainos Adult ®Test Line/System Drain 0 2' 4' 6' aPressureGauge ® Family Home 1/4"GRAPHIC SCALE � (Optional)Flow Switch(a)Pressure Switch 11 9 Run-Time Controller Discharge Check Valve y 1 7 , Suction Shut-of Valve 49 Performance - —� 18304 Cedarbough Lp GPM 0 20 25 30 35�40 45 50 PSI 55 52 51 50 48 46 43 40 Arlington,WA 98223 Drawing Title FIRE SPRINKLER PLAN City of Arlington Building Department APPROVED Kevin Olander- 04/30/2026 No changes authorized unless approved by the Building Official Date: 04/04/2026 Job Number: 10-0015 Designer: C.Pleasant S P R I N K L E R S U M M A R Y S Y S T E M D E S I G N C R I T E R I A PARCEL# 00738500402400 TYPE MODEL# SIN FINISH TEMP. ORIFICE K-FACTOR MAX.SO.FT. MIN.SPACING OTY. TYPE SYSTEM: X❑WET ❑DRY ❑PA NFPA STANDARD: ❑#13 ❑#13R❑#13D❑X O RESIDENTIAL CONCEALED PENTENT(SENJU) RC-RES SS8464 WHITE 205' 1/2" 4.9 16'X 16' 8'-0' 21 NFPA EDITION: 2025 Drawing No. x Sprinklers-ARE-NOT required to be located in the center or quarter points of ceiling tiles. F P NO 0 01 II YV OCCUPANCY: RESIDENTIAL HAZARD: RESIDENTIAL SITE PLAN P I P E T Y P E S A N D F I T T I N G T Y P E S N.T.S TOTAL SPRINKLERS INSTALLED THIS PROJECT= 21 PIPING: CPVC FITTINGS: CPVC SCOPE OF WORK: THIS PROJECT WILL CONSIST OF THE INSTALLATION OF A NEW RESIDENTIAL RA EN SPRINKLER SYSTEM.POINT OF CONNECTION WILL BE AT THE DISCHARGE VALVE OF THE TALCO HH3 TANKRUMP SYSTEM. EXCLUSIONS: FIRE PROTECTION PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT (E)DECK ELECTRICAL WIRING OF ANY KIND,INC LUDING BUT NOT LIMITED TO WATER FLOW 3204CrystalRid eDrSE (E)SUNROOM SWITCH,ELECTRIC BELL,AND TAMPER SWITCH g Puyallup,WA 98372 CENTRAL STATION MONITORING EQUIPMENT,WIRING AND SERVICES Phone:253-387-1090 ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO:BACKFILL,SELECT FILL, www.ravenfp.com PATCHING,SAW CUTTING,LAWN REPAIR,LANDSCAPING,TREE REMOVAL, WWW. p.COI'T1 DN STERILIZATION,DEVELOPMENT FEES AND CITY CONNECTION. LIC#RAVEN FP750PN 8'-D" 2'-7" 6'-4" 8'-D" 2'-3^ 7'-91, 4'-4" 15'-` 8' � GENERAL NOTES: (E) 1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED, -.as�eERTIF�elTE of eo xFETEMC LIT, o 2. HEAT TO BE PROVIDED BY THE OWNER AT ALL TIMES FOR WET TYPE SPRINKLER F �x SYSTEMS. FIRE SPRINKLER SYSTEMS e (E)C 3. H R E PROTECTION CONTRACTO R SHALL NOT BE RESPONSI BEE FOR TH E AS I CITY o N OFFICE OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE PROTECTION SYSTEM ( ) O (E)KITCHEN OR ANY APPURTENANCES THEREOF ' RnvExR i 0 4. ALL PIPE TO BE CPVC U.N.O. - - 04/04I2026 E BE R M A R... °0 0 _ I ( ) ❑ 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF555O.FT.ANDLE55 R ......... (E)FA ILYROOM NUMB (NFPA13D20198.3.2). I 6. SPRINKLERS SHALL NOT BE REgUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, Cn AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: (E) ATH ~� 3-O ® 2)THE WALLS AND CEILING ARE SURFACEDCE DOES NOT ED 24 SOFT WITHNONCOMBUSTIBLE OR I2-5 LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN FPA 220.(NFPA 13D 2019) J ~ 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES, TANK SHED °N CARPORTS,AND SIMILAR STRUCTURES.(NFPA 13D 2019) RESIDENTIAL FIRE T rC7 SETPUMP &TANK 0 Q.FT Co 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, HH3-15OSP I -��i _ In (N)BATH --o PENTHOUSE EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED CLOSET CLOSET �' IE)PONYMUL VENTILSPACESATION TIONEQUI1)DICATED MEET,EICULI FLOOROANDCONTAINI ELEVATOR RSHAFS,DWELLIN UNIT (E) ATH 7 SQ 9 SQ U VENTI ATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS,CRAWL 1O3 1 1 0 SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED (()) 62F FOR LIVING PURPOSES.(NFPA 13D 2019) UM I I 0-8 I I 9. SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR -� 9-3 ,„w 9-7 9-4 8-D CLOSETS(REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE A DOOR OR UNPROTECTED PENETRATIONS DIRECTLY CLOSET CNA ROOM N INTO THE DWELLING UNIT.(NFPA 13D 2019) v v I cv 10 SQ.FT `" 9'-4)r 1~cv ((E)BEDROOM 10. AMAIN DRAIN LETO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH J lO2 ° NFPA 13D 2019.HUB-DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. I2 5 1 11. NO GYP.BD.CE ICINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL - (E)LI NG T """"" INSPECTION IS COMPLETE. FUR. f 12, MAXIMUM RESIDENTIAL PENDENT SPRINKLER MAXI SPACINGRESIDENTIAL DENTI'.MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14'X14'.MAXIMUM RESIDENTIAL SIDEWALL °i I���,ryl � ~+ SPRINKLER SPACING I6'X20'.U.N.O. E)BEDROOM (E)BEDROO C J e�P "" T 13. MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-OO.C'.MINIMUM DRY _ ILJf 1 I-l�l SIDEWALL SPRINKLER SPACING 6-00.C'.MINIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 8-OO.C. CLOSET 3 8 -7 A 10 SQ F .J 14. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D 2019 _1• g'_5y^ w g (N I BEDROOM D [j - 6 15. PIPE SHALL BE REQUIRED TO REMAIN ON A 2/"CENTERLINE ON THE TOP OF j., THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE ULU \ PRIORITY OVER OTHER TRADES. —ROBE ATT \ 16. (7.5.6.1)SPRINKLERS INSTALLED WHERE MAXIMUM AMBIENTCEILING LIT ACC. ` Co TEMPERATURES DO NOT EXCEED 100 DEGREES FAHRENHEIT SHALL BE ORDINARYTEMPERATURE-RATED OF INTERMEDIATE TEMPERATURE RATED 8-0• 6'-4^�rl 2'-7` 8-0^ '` SERINKEER5 THROUGHOUT UN LESS MODIFIED BY REQUIREMENTS OF 7.5.6.3 �E PORCH �i � DIN naoRoeL - I 1 4- H� H1 (E)RAMP (N) EDROOM F (N BEDROO E City of Arlington Building Department 0 APPROVED REMOTE AREA 1 0 Kevin Olander- 04/30/2026 Revisions No changes authorized unless approved by 9'-5' 2'-6• 7'-0" the Building Official Contract Name: Weikainos Adult SPRINKLER LAYOUT Family Home 1/4"=1'-0.. 0 1/42 GRAPHIC SCALE B WEIKAINOS AFH 18304 Cedarbough Lp REMOTE AREA 1 Arlington,WA 98223 HYDRAULIC CALC. INFORMATION NEW HYDRAULIC PIPE SIZES GROUND FLOOR Drawing Title NFPA 13D FIRE SPRINKLER PLAN PIPE SIZE 1' 2 HEADS HYDRAULIC DESIGN DATA 1' BRANCHLINES Hazard Class. RESIDENTIAL 1' MAIN s stem area 2t 92 SQ.FT. I' PUMP CONNECTION E""T e WET Calc'd Oansit 0.05 GPM SQ.FT. Remote Area Si- 238.2 SQ.FT. PIPE SIZES ARE BASED ON THE HYDRAULIC Covers a Per Head 256 SQ.FT. CALCULATION OF THE GROUND FLOOR REMOTE AREA. Demand 26.0 GPM® 21.3 PSI CALCULATIONS PROMDE A 29,42 PSI SAFETY FACTOR(58.0%). 0 Denotes Reference Points Date: 04/04/2026 Job Number:10-0015 Designer: C.Pleasant S P R I N K L E R S U M M A R Y S Y S T E M D E S I G N C R I T E R I A PARCEL# 00738500402400 TYPE MODEL# SIN FINISH TEMP. ORIFICE K-FACTOR MAX.SQ.FT. MIN.SPACING QTY. TYPE SYSTEM: X❑WET ❑DRY ❑PA NFPA STANDARD: ❑#13 ❑#13R❑#13D❑X O RESIDENTIAL CONCEALED PENTENT(SENJU) RC-RES SS8464 WHITE 205' 1/2^ 4.9 16'X 16' 8'-0. 21 NFPA EDITION: 2025 Drawing No. xSprinklers-ARE NOT-required to be located in the center or quarter points of ceiling tile!. F P 002 YV OCCUPANCY: RESIDENTIAL HAZARD: RESIDENTIAL P I P E T Y P E S A N D F I T T I N G T Y P E S TOTAL SPRINKLERS INSTALLED THIS PAGE = 21 PIPING: CPVC FITTINGS: CPVC FIP E tA FIRE PROTECTION City of Arlington Building Department APPROVED Kevin Olander-04/30/2026 3204 Crystal Ridge Dr SE, Puyallup, WA 98372 No changes authorized unless approved by the Building Official www.ravenfp.com RAVENFP750-PN Fire Sprinkler System Material Submittal Packet Project Name: Weikianos Adult Family Home Project #: 10-0015 Project Address: 18304 Cedarbough Loop Arlington, WA 98223 Project Parcel #: 00738500402400 --------------------------- Ex Ires WASHINGTON STATE DECPt.26 CERTIFICATE OF COMPETENCY FIRE SPRINKLER SYSTEMS Christine Cheryl Pleasant 7662-0126-C Levc13 Raven Fire Protection j RAVENFP750PN j ——�— 04/04/2026 311gnature Date j .............................a Raven Fire Protection LLC Material Submittal Packet Table of Contents Weikainos AFH Project Number: 10-0015 Description: Manufacturer: Concealed Pendent Sprinkler QR Senju Sprinkler CPVC Pipe and Fittings FlameGuard Cement CPVC Spears Hangers, Pipe straps ASC Pump and Tank HH3-150SP Talco SENJU t SPRINKLER Model RC-RES - rf K-Factor: 4.9 SIN: SS8464 Residential Lead Free Flat Concealed Sprinkler, Pendent C@ US LISTED ALS NSF/ANSI/CAN61&372 Us GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D;wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9(70.6 LPM/bar'/2)K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act(S.3874)endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. Vwww.senjusprinkler.com Page 1 of 8 Document No.U08516A•12-15-2025 WARNINGS The installation and maintenance of Model RC-RES must strictly adhere to the guidelines specified in this document, as well as comply with the standards and regulations set forth by the National Fire Protection Association (NFPA)and any other applicable Authorities Having Jurisdiction. Additionally, it is crucial that the final approval for installation is obtained from Authorities Having Jurisdiction. Failure to comply with these requirements may result in a compromise to the integrity and functionality of the devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. TECHNICAL DATA • Approvals: Marking Lot No. • cULus Listed 1/2"IN PT 2-1/16"(052 mm) Year of Manufacture SIN:SS8464 • NSF/ANSI/CAN 61, NSF/ANSI/CAN 372 K-Factor:K4.9 3 Temperature Rating: • Sprinkler Identification Number(SIN): SS8464 1 162°F(72°c)or E 205°F(96°C) 4 UL Mark • Maximum Working Pressure: 175psi (12.1bar) 5 Control No.:6P37 " ALS Mark:NSF 61/372 • Discharge Coefficient(Nominal K-Factor): e == RES SPKR - ^� Assembly Location 0 K= 4.9 GPM/psi'/2 (70.6 LPM/bar'/2) _" "^_ none(Japan)or A(USA) • Temperature Rating: - D Body(Copper Alloy) p g O Deflector(Phosphor Bronze) 2-5/8" fd68 mm)) O Gasket(PTFE) • 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate or 3-1/4"(083 mm) ®Fusible Metal(Solder) or 2-5/8"square(068 mm) O Heat Collector(Copper) • 205°F(96°C) Sprinkler with 162°F (72°C) Cover Plate ©Cover Plate Assembly • Color Code (Sprinkler) Figure 1:Model RC-RES K=4.9 • 162°F (72°C): Uncolored • 205°F(96°C): White Color Code Markin Deflector • Color Code (Cover Plate) SIN:SS8464 K-Factor:K4.9 • 140°F (60°C): No Mark Temperature Rating: 162°F(72°C)or • 162°F (72°C): White-Colored Mark " k 205°F(96°c) Zx UL Mark • Vertical Adjustment: 1/2 inch (12.8 mm) x b • Cover Plate Finishes: ' ` ti • Standard Finishes: White, Ivory, Beige, Brown, Black, Nickel, Copper, Wood Grain Cover Plate Sprinkler • Custom Finishes: Custom color and custom pattern (Top View) (Bottom View) cover plates are available on special order. Contact a Figure 1.1:Marking(Color Code) Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. • Physical Characteristics: Ref. Figures 1 and 1.1 Vwww.senjusprinkler.com Page 2 of 8 Document No.U08516A•12-15-2025 OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once.As a result, the Deflector drops down to the intended position.Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) ZMNIP F!�. , Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge Figure 2.Operation Process (For illustrative purposes only) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Notes Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures,and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria,which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details,as appropriate. In some instances,the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R,or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions,room dividers,overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment(as defined by NFPA 13D,13R,or 13)must be kept as few as possible while observing all guidelines relating to obstructions and spacing. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Vwww.senjusprinkler.com Page 3 of 8 Document No.UO8516A•12-15-2025 Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Sprinkler Nominal Maximum Ambient Ceiling Temperature Rating of the Classification Temperature Rating Temperature Cover Plate Assembly Ordinary 1620F (72-C) 100°F (38°C) 140°F (60°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: 1. Chlorine ion and Chloride environment Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. 2. Sprinkler system piping with Copper Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA(Copper Development Association)—Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. • A minimum discharge of 0.1 GPM/sq.ft.[4.07LPM/sq.m]over the"design area"comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. Vwww.senjusprinkler.com Page 4 of 8 Document No.U08516A•12-15-2025 Table A. NFPA 13D & 13P Wet Pipe Hydraulic Design Criteria for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Maximum Ordinary Temperature Intermediate Temperature Coverage Spacing Rating 162°F(72°C) Rating 205°F(96°C) Deflector to Installation Minimum Area(,) Spacing Ft.xFt. Ft' Flow(b)GPM PressureN Flow(b)GPM Pressure"� Ceiling Type Ft.�m) (m x m) (m) (LPM) PSI(bar) (LPM) PSI(bar) 12 x 12 12 13 7.0 13 7.0 Smooth (3.7 x 3.7) (3.7) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8 to 7/8 Inches. 14 x 14 14 13 7.0 13 7.0 (4.3 x 4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per 16 x 16 16 13 7.0 13 7.0 NFPA 13D, Concealed 8 (4.9 x 4.9) (4.9) (49.2) (0.48) (49.2) (0.48) 13R or 13. (2.4) 18 x 18 18 17 12.0 17 12.0 Installed in (5.5 x 5.5) (5.5) (64.4) (0.83) (64.4) (0.83) beam 3/8 to 7/8 inches 20 x 20 20 21 18.4 21 18.4 below bottom (6.1 x 6.1) (6.1) (79.5) (1.27) (79.5) (1.27) of beam. a. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. b. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet(2.4m).The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation,sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation.After the installation is completed,the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft•lbs(9.5 to 19.0 N•m)to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque,this could result in damage to the sprinkler inlet,which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Removal Tool for RC to the left with force when placing the two hook arms into place.The installed sprinkler may become loosened,which may cause water leakage. Vwww.senjusprinkler.com Page 5 of 8 Document No.U08516A•12-15-2025 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical FlameGuard®Technical Information FlameGuard F ENGINEERING GUIDE Contact Spears® for any Information not found. Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 14 See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH—FG-1—T.htm 1/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical �Ptif, FlameGuard® System Overview Complete System of Pipe, Fittings $ Solvent Cement Corrosion Resistant•Superior Flow•Ease of Installation 9 M FIRE SMNKUR MOW" Spears° FlameGuard° CPVC Fire Sprinkler Products provide a cost effective alternative to metal systems with advantages of high corrosion resistance, improved system hydraulics, ease of installation and quick assembly with readily available tools. CPVC Fire Sprinkler Systems are based on proven products that have been in continuous service for over 40 years. Spears° FlameGuard° products are approved by UL°, FM° Global, LPCB and Certified by NSF International for potable water use. Check local codes for restrictions and limitations. ;��, .. Stu •r -+. ndlu �q Page 15 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 2/40 12/2/25,3:17 PM Spears@ Super Sourcebook FlameGuard®Technical FlameGuard® System Overview hPlr�Rk _J Spears° FlameGuard° . . . The Leader in Innovative CPVC Fire Sprinkler System Products Easy Installation for Lower Costs Corrosion Resistant CPVC Material Does Not FlameGuard° CPVC system installations significantly reduce Sustain Biological Growth costs over conventional metal piping by virtually eliminating Unlike metal systems, FlameGuard°CPVC products never rust, prefabrication. Systems can be fully installed on site using scale or pit and do not sustain biological growth - a cause of solvent cement joining methods. Microbiologically Influenced Corrosion (MIC) which can destroy metal fire sprinkler systems from the inside out. UL®Listed for U.S.and Canada in NFPA 13,1311&13D Systems Superior Flow Characteristics for Lower FlameGuard° CPVC Fire Sprinkler Products are ULO listed for Friction Losses U.S. and Canada applications for Light Hazard occupancies as The smooth-wall interior surfaces of FlameGuard° CPVC defined in NFPA 13,Residential occupancies up to and including systems result in reduced friction loss over metal systems. The 4-stories as defined in NFPA 13R, and Residential occupancies design flow characteristics remain constant throughout the life of for one and two family dwellings and manufactured homes as the product because there is no interior corrosion in the system defined in NFPA 13D.Consult Spears®FlameGuard®CPVC Fire due to microbiological activity. Sprinkler Products Installation Instructions and NFPA Standards for additional applications including air plenum, system risers, Pressure Rated to 175 psi(1.21 Mpa)@ 150°F(66°C) concealed, exposed, underground, combustible attic, garage, FlameGuard°CPVC Products are produced in combinations of basement and low pressure dry piping installations. Schedule 40 and Schedule 80 Fitting configurations conforming to ASTM F 438 or F 439 standards and FlameGuard°SDR 13.5 Full Limited Lifetime Warranty CPVC Fire Sprinkler Pipe conforming to ASTM F 442 standards. FlameGuard° CPVC Fire Sprinkler Products carry a limited ULO Rated working pressure is 175 psi(1.21Mpa)@ 150°F lifetime warranty against defects in material or workmanship. (66°C)(LPCB rated to 120°F)(49°C). Consult Spears®warranty for additional details. Pioneer in Molded-in Metal Insert Head Adapters Spears® pioneered the development of the FlameGuard° molded-in-place metal thread insert for connection of sprinkler heads to CPVC fire sprinkler systems, plus 01 Metal FIPT threaded female adapters for metal-to-plastic transitions. Developed the Special Reinforced (SR) Head Adapters 41# Spears® FlameGuard°continuous improvement program developed the technology to produce a superior patented plastic threaded fitting - the Special Reinforced (SR) Design. This unique design incorporates a patented thermoplastic compression process that equalizes stresses generated by tapered thread joint make-up.All CPVC plastic body and threads provide a more uniform construction and improved corrosion resistance. Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 16 See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 3/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical �Ptif, FlameGuard® System Overview Now,the Revolutionary TorqueSafe'" Gasket Sealed Head Adapter • Requires NO Thread Sealants • Eliminates Stress • Prevents Over Tightening • Provides Easy Frame Alignment Spears'revolutionary design features a special molded-in-place Brass Thread Insert fitted with an elastomer gasket seal at the base of the threads. The gasket seal allows a modified thread design that eliminates radial stress and associated problems typical with tapered thread joint make up. The insert is designed to rotate for easy sprinkler frame alignment without overtightening. Patent No.7,458,613. Full Assortment of Specialty Products&Fitting Configurations Spears' FlameGuard° provides the specialty fittings needed in today's fire sprinkler systems, such as the adjustable drop nipple for fine-tuning to finished ceiling height, and ringed head adapter for ease of locating during installation. Plus, Spears' FlameGuard° line offers a full assortment of CPVC fire sprinkler fitting configurations including Tees, Elbows, Flanges, Couplings, Repair Couplings, Caps, Male Adapters, Grooved Coupling Adapters and Unions, sizes 3/4" through 3"and an expanded assortment of GripLoCTM Couplings, Repair Couplings, Tees, 90' Elbows and Caps. Complete Size Range of CPVC Pipe 'k �� - . Spears® FlameGuard® CPVC Fire Sprinkler Pipe is available in sizes 3/4" to 3". Conforms to ASTM F 442 standard for SDR 13.5 CPVC pipe. Spears'Solvent Cements&Thread Sealant FlameGuard°products should be installed using Spears°FS-5 One-Step Solvent Cement. For threaded joints, use Spears° BLUE 75— Thread Sealant that has been tested for compatibility with FlameGuard° CPVC Fire Sprinkler Products. Spears'TorqueSafe'M Gasket Sealed Adapter requires no sealant. Consult sprinkler head manufacturer prior to use. A. iY, •u Page 17 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH—FG-1—T.htm 4/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical 101, FlameGuard® General Information Er3 The information contained in this section is based on current information and product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spearse Technical Services Department[West Coast:(818)364-1611-East Coast:(678)985-1263]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems.Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system.All installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY,all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears®Manufacturing Company FlameGuard®CPVC Fire Sprinkler Piping Products Installation Instructions-FG-3 NOTE - Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears®Regional Distribution Center. SOLVENT CEMENT CONNECTIONS - Spears® Manufacturing Company recommends the use of Spears® FS-5 One Step solvent cement for joining Spears®products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION - Spears® Manufacturing Company recommends the use of Spears® BLUE 75Tm Thread Sealant. This product has been tested by Spears®and the sealant manufacturer for compatibility with the Spears® CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product.WARNING:OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing-generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft.lbs.of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS -This type of connection can only be made with Spears®TorqueSafe' style Gasket Sealed Female Sprinkler Adapters.DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug is all that is needed to seal this special connection. Installation Training Available-Contact Spears®Technical Services for Details FlameGuard° Products must be installed in accordance with Spears®CPVC Fire Sprinkler Piping Products Installation Instructions, National Fire Protection Association Standards 13, 13R, 13D, and in accordance with local codes. Code requirements and field conditions may differ.It is the responsibility of the installing contractor to ensure that the product is suitable to meet these requirements. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of M=Outside diameter of socket/thread hub;±1/16 inch. socket/thread;90°elbows,tees,crosses;±1/32 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 H=Intersection of center lines to face of fitting;90°elbows tees,crosses; inch. ±1/32 inch. Q=Width of flats;±1/16 inch. J = Intersection of center lines to bottom of socket/thread; 45' elbows; W=Height of cap;±1/16 inch. ±1/32 inch L=Overall length of fittings;±1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5 ASTM F 442 Part Number Nominal Size Average O.D. Average I.D. Approx.Weight Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 19.1 1.050 26.7 .874 22.5 0.168 CP-010 1 25.4 1.315 33.4 1.101 28.2 0.262 CP-012 1-1/4 31.8 1.660 42.2 1.394 35.6 0.418 CP-015 1-1/2 38.1 1.900 48.3 1.598 40.7 0.548 CP-020 2 50.8 2.375 60.3 2.003 50.9 0.859 CP-025 2-1/2 63.5 2.875 73.0 2.423 61.5 1.257 CP-030 3 76.2 3.500 88.9 2.950 75.0 1.867 "Lead Free"low lead certification-unless otherwise specified, all Spears®FlameGuard®fittings specified here-in are certified by NSF International to ANSI/NSF® Standard 61, Annex G and is in compliance with California's Health & Safety Code Section 116825 (commonly known as AB1953)and Vermont Act 193.Weighted average lead content—0.25%.Spears®PVC and CPVC Pipe, Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems. Spears®offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications. However, certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 18 See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 5/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical i�PE fk FlameGuard®TorqueSafeTm Gasket Sealed Sprinkler Head Adapters w/Brass Thread Inserts The CPVC Fire Sprinkler Head Adapter You've Been Waiting For... • Eliminates Radial Stress • Requires NO Thread Sealants • Eliminates Sealant Incompatibility • Prevents OverTightening • Provides Easy Frame Alignment • UL° Listed for U.S. and Canada • FM°Approved Spears' TorqueSafe'M revolutionary design features a special molded-in-place Brass Thread Insert fitted with an elastomer gasket seal at the base of the threads. The gasket seal allows a modified thread design that eliminates radial stress and associated problems typical with tapered thread joint make up. The insert is designed to rotate during head installation for easy sprinkler frame alignment without over tightening. r '• No Sealant=No More Problem's. Using incompatible thread pastes and pipe dopes is the major cause of environmental stress cracking in plastics. Tape sealants CPVC are far too frequently improperly or excessively applied. These Body problems are fully eliminated. .ti Y•• fi Brass I NO-Stress Thread Design Thread The modified straight thread design is engineered to provide a tight Insert joint at full engagement without radial stress from tapered thread _ expansion.An internal gasket retaining lip serves as a positive stop against overtightening. No stress assures years of long,trouble free EPDM service. Gasket Spinkler Gasket Sealing Male An EPDM gasket has been engineered for sealing against the Thread sprinkler head. The NPT male thread starts on all sprinkler heads provide a uniform surface for positive, reliable seal. Hundreds of tests have been performed using virtually all brands of heads and .S� even rough, galvanized pipe nipples without any damage or loss of += sealing. Pr} t �! 1 � { t Patent No.7, ,613 Page 49 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH—FG-1—T.htm 36/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuarde Technical FlameGuard®TorqueSafeTm Gasket Sealed Sprinkler Head Adapters w/Brass Thread Inserts Simply Hand Install Head &Align Wrench Alignment If necessary for alignment, rotate sprinkler head clockwise until frame is properly aligned.Gasket will compress or brass will rotate with sprinkler head until aligned.Caution:DO NOT use back-up wrench on brass insert hex. 1 R fi rr 1 T({ Pi R�tNE a!r"grass s) Krass"' / insert insert Gasket will compress,or Brass -�.. will rotate with Sprinkler Head to allow alignment i 00 NOT Haserse or Sack up,Threaded Assemhiv,it ovur-adlusted,conittme to rotate clacitwtse until orowiv allgned. Installing Concealed Sprinkler Escutcheons Fulfuw these steps to assure extra tirm seating of Head 1. Install Sprinkler Head/Escutcheon. 2.Tighten Sprinkler Head/Escutcheon with manufacturer's wrench until snug. Manufacturer's wrench install Cover Finger Tight 3. Install Escutcheon Rover y� i Made m the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 50 See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH—FG-1—T.htm 37/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuard®Technical FlameGuard®SofTorqueTM SR One-Piece Gasket Sealed, Special Reinforced Sprinkler Head Adapter TM Introducing SofTorque SR. . . The U1 iMate VPV;Fire Sprinkler Head Adapter, Spears°Combines Patented Special Reinforced (SR) Plastic Thread & Gasket Sealed Technology. . . • Unitized One-Piece Design • NO Lead -NSF®Certified • NO Radial Stress • NO Paste or Tape Sealants • NO Leaks • NO OverTightening • Provides Easy Frame Alignment • Suitable For Multipurpose Systems • FM°Approved Patented Easiest Installation, Finger Tight Plus 1-Turn Then Align Sprinkler Head Spears' new SofTorqueTM SR design features a special formed-in-place elastomer gasket seal at the base of Special Reinforced (SR)plastic threads. The thread design and gasket seal eliminate radial stress typical in tapered thread joint make up, plus gasket compresses to allow sprinkler frame alignment without overtightening. Special SR design provides additional strength and thread reinforcement.Available in size 1"Socket x 1/2"SR FIPT, Spears' Part Number 4235-130GSR. For additional sizes and configurations,contact Spears'. Unitized Construction One-Piece all CPVC construction eliminates potential for problems from conventional 2-piece construction designs. No metal water contact eliminates corrosion. NO Lead -NSF®Certified All plastic construction is NSF® Standard 61 Annex G, Certified Lead Free in compliance with US Safe Drinking Water Act(SDWA) Special Gasket Sealing&Alignment Feature EPDM gasket has been engineered not only for proper sealing, but provides proportional compression as threads are tightened for -,..>., -,�..r sprinkler head frame or sidewall deflector alignment. No Sealant= No More Problems. Eliminates problems from incompatible thread pastes and pipe dopes or improperly applied thread tape. Reinforced No Stress Thread Design Spears®patented Special Reinforced (SR)thread design eliminates ,` -` +6 "'r` radial stress and reinforces against splitting plastic threads. No stress assures years of long,trouble free service. Page 51 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 38/40 12/2/25,3:17 PM Spears®Super Sourcebook FlameGuarde Technical FlameGuard®QuickTorqueTM SR Gasket Sealed, Special Reinforced Sprinkler nPk'ilf� Head Adapter with Metal Threads QuickTorque TM The One Head Adapter That Has It ALL Spears° New FlameGuard° QuickTorqueTI CPVC Sprinkler Head Adapter uses a combination of high-strength materials to provide the most reliable, worry-free adapter in the industry: CPVC Body for Unsurpassed Corrosion Resistance High grade EPDM Gasket for Reliable Sealing Metal Thread & Exterior Reinforcement for Superior Strength x' E The thread design and gasket seal eliminate radial stress found in tapered thread joint make up, the gasket compresses to allow sprinkler frame alignment without over tightening. 4235-101GMR 3/4"xl/2" 4235-13OGMR 1"x1/2" I*11 t c�clllkti:%ti� �uNl ✓Metal Thread Eliminates Cross Threading ThfF'B0q,'- . r6"f0fk� rrlUnt ✓Requires NO Thread Sealant r i ✓High Grade EPDM Compression Gasket j • S.` �`g.D ;?+�.1�V,,;h� `� Allows Quick, Easy Head Alignment ✓Easiest Installation, Finger Tight Plus 4 1-Turn Then Align Sprinkler Head ✓NSF®Certified Lead-Free for Use in F . Potable Water Systems-Suitable for Use in Multi-purpose Systems fit_, 4 Progressive Products From Spears° M!ltit' "ftiYglS ^' Innovation & Technology �!%I., Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 52 See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 39/40 12/2/25,3:17 PM Spears®Super Sourcebook i F' FlameGuard®Technical ff FlameGuard®QuickTorqueTM SR Gasket Sealed, Special Reinforced Sprinkler Head Adapter with Metal Threads 74.�fAi+i�lBt«O p 4 .�BL E ti rNAFAO SGUN 75 DO NOT USE THREAD SEALANT Tighten One Additional Turn Using Wrench "Mic Hand Tighten Only EPDM Gasket Metal Threads Gasket Sealed Align Sprinkler Head Horizontally / 00 l Align Sprinkler Head Horizontally Page 53 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company See Spears®Product Sourcebook for product offerings 63.156.201.111/SMC/FGTECH FG-1 T.htm 40/40 GHS SAFETY DATA SHEET SPEAKS Date Revised: JAN 2024 Spears®FS-5 One-Step Low VOC Cement for CPVC Fire Sprinkler Systems Supersedes: APRIL 2020 SECTION I-PRODUCTAND COMPANYIDENTIFICATION PRODUCT NAME: Spears®FS-5 One-Step Low VOC Cement CPVC Fire Sprinkler Systems PRODUCT USE: Solvent Cement for CPVC Plastic Pipe MANUFACTURER: Spears®Manufacturing Company SUPPLIER: 15853 Olden Street,Sylmar,CA 91342 Tel.818-364-1611 EMERGENCY:Transportation/Medical Issues:Tel.800-535-5053 or 352-323-3500(outside of USA)INFOTRAC SECTION 2 -HAZARDS IDENTIFICATION GHSCLASSIFICATION: Health Environmental Physical Acute Toxicity: Category 4 Acute Toxicity: None Known Flammable Liquid Category 2 Skin Irritation: Category 3 Chronic Toxicity: None Known Skin Sensitization: NO Eye: Category 2B GHS LABEL: O O O Signal Word: WHMISCLASSIFICATION: CLASS B,DIVISION 2 Danger Hazard Statements Precautionary Statements H225:Highly flammable liquid and vapor P210:Keep away from heattsparks/open flames/hot surfaces-No smoking H319:Causes serious eye irritation P261:Avoid breathing dust/fume/gas/mist/vapors/spray H332:Harmful if inhaled P280:Wear protective gloves/protective clothing/eye protection/face protection H335:May cause respiratory irritation P337+P313:Get medical advice/attention H336:May cause drowsiness or dizziness P403+P233:Store in a well ventilated place.Keep container tightly closed H351:Suspected of causing cancer P501:Dispose of contents/container in accordance with local regulation EUH019:May form explosive peroxides SECTION 3-COMPOSITION/INFORMATION ON INGREDIENTS CAS# EINECS# REACH CONCENTRATION Pre-registration Number %by Weight Tetrahydrofuran(THF) 109-99-9 203-726-8 05-2116297729-22-0000 30-60 Methyl Ethyl Ketone(MEK) 78-93-3 201-159-0 05-2116297728-24-0000 2-25 Cyclohexanone 108-94-1 203-631-1 05-2116297718-25-0000 5-15 Acetone 67-64-1 200-662-2 05-2116297713-35-0000 1-5 All of the constituents of this adhesive product are listed on the TSCA inventory of chemical substances maintained by the US EPA,or are exempt from that listing. *Indicates this chemical is subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right-to-Know Act of 1986(40CFR372). #indicates that this chemical is found on Proposition 65's List of chemicals known to the State of California to cause cancer or reproductive toxicity. SECTION 4 -FIRST AID MEASURES Contact with eyes: Flush eyes immediately with plenty of water for 15 minutes and seek medical advice immediately. Skin contact: Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water. If irritation develops,seek medical advice. Inhalation: Remove to fresh air. If breathing is stopped,give artificial respiration. If breathing is difficult,give oxygen. Seek medical advice. Ingestion: Rinse mouth with water. Give 1 or 2 glasses of water or milk to dilute. Do not induce vomiting. Seek medical advice immediately. Likely Routes of Exposure: Inhalation,Eye and Skin Contact Acute symptoms and effects: Inhalation: Severe overexposure may result in nausea,dizziness,headache. Can cause drowsiness,irritation of eyes and nasal passages. Eye Contact: Vapors slightly uncomfortable. Overexposure may result in severe eye injury with corneal or conjunctival inflammation on contact with the liquid. Skin Contact: Liquid contact may remove natural skin oils resulting in skin irritation. Dermatitis may occur with prolonged contact. Ingestion: May cause nausea,vomiting,diarrhea and mental sluggishness. Chronic(long-term)effects: Category 2 Carcinogen SECTION 5 -FIREFIGHTING MEASURES Suitable Extinguishing Media: Dry chemical powder,carbon dioxide gas,foam,Halon,water fog. HMIS NFPA 0-Minimal Unsuitable Extinguishing Media: Water spray or stream. Health 2 2 1-Slight Exposure Hazards: Inhalation and dermal contact. Flammability 3 3 2-Moderate Combustion Products: Oxides of carbon,hydrogen chloride and smoke. Reactivity 0 0 3-Serious PPE B 4-Severe Protection for Firefighters: Self-contained breathing apparatus or full-face positive pressure airline masks. SECTION 6 -ACCIDENTAL RELEASE MEASURES Personal precautions: Keep away from heat,sparks and open flame. Provide sufficient ventilation,use explosion-proof exhaust ventilation equipment or wear suitable respiratory protective equipment. Prevent contact with skin or eyes(see section 8). Environmental Precautions: Prevent product or liquids contaminated with product from entering sewers,drains,soil or open water course. Methods for Cleaning up: Clean up with sand or other inert absorbent material. Transfer to a closable steel vessel. Materials not to be used for clean up: Aluminum or plastic containers. SECTION 7 -HANDLING AND STORAGE Handling: Avoid breathing of vapor,avoid contact with eyes,skin and clothing. Keep away from ignition sources,use only electrically grounded handling equipment and ensure adequate ventilation/fume exhaust hoods. Do not eat,drink or smoke while handling. Storage: Store in ventilated room or shade below 33°C(90*F)and away from direct sunlight. Keep away from ignition sources and incompatible materials:caustics,ammonia,inorganic acids,chlorinated compounds,strong oxidizers and isocyanates. Follow all precautionary information on container label,product bulletins and solvent cementing literature. Page 1 of 2 FS5-6-0124 SECTION 8-PRECAUTIONS TO CONTROL EXPOSURE/PERSONAL PROTECTION EXPOSURELIMITS: OSHA CAL/OSHA CAL/OSHA Component ACGIHTLV ACGIHSTEL OSHAPEL OSHASTEL: PEL-Ceiling PEL Ceiling AL/OSHA STEL Tetrahydrofuran(THF) 50 ppm 100 ppm 200 ppm N/E N/E 200 ppm N/E 250 ppm Methyl Ethyl Ketone(MEK) 200 ppm 300 ppm 200 ppm N/E N/E 200 ppm N/E 300 ppm Cyclohexanone 20 ppm 50 ppm 50 ppm N/E N/E 25 ppm N/E N/E Acetone 500 ppm 750 ppm 1000 ppm N/E N/E 500 ppm 3000 ppm 750 ppm Engineering Controls: Use local exhaust as needed. Monitoring: Maintain breathing zone airborne concentrations below exposure limits. Personal Protective Equipment(PPE): Eye Protection: Avoid contact with eyes,wear splash-proof chemical goggles,face shield,safety glasses(spectacles)with brow guards and side shields,etc. as may be appropriate for the exposure. Skin Protection: Prevent contact with the skin as much as possible.Butyl rubber gloves should be used for frequent immersion. Use of solvent-resistant gloves or solvent-resistant barrier cream should provide adequate protection when normal adhesive application practices and procedures are used for making structural bonds. Respiratory Protection: Prevent inhalation of the solvents. Use in a well-ventilated room. Open doors and/or windows to ensure airflow and air changes. Use local exhaust ventilation to remove airborne contaminants from employee breathing zone and to keep contaminants below levels listed above. With normal use,the Exposure Limit Value will not usually be reached.When limits approach,use respiratory protection equipment. SECTION 9 -PHYSICAL AND CHEMICAL PROPERTIES Appearance: Red,heavy syrupy liquid Odor: Ether-Like Odor Threshold: 0.88 ppm(Cyclohexanone) pH: Not Applicable Melting/Freezing Point: -108.5-C(-163.3'F)Based on first melting component:THF Boiling Range: 66°C(151°F)to 156°C(313°F) Boiling Point: 66°C(151°F)Based on first boiling component:THF Evaporation Rate: >1.0(BUAC=1) Flash Point: -20°C(-4°F)TCC based on THF Flammability: Category 2 Specific Gravity: 0.857±0.01 @ 23GC±20(730F±3.60) Flammability Limits: LEL:1.1%based on Cyclohexanone Solubility: Solvent portion soluble in water. Resin portion separates out. UEL:11.8%based on THF Partition Coefficient n-octanol/water: Not Available Vapor Pressure: 129 mm Hg @ 20°C(68°F)based on THF Auto-ignition Temperature: 321°C(610°F)based on THF Vapor Density: >2.0(Air=1) Decomposition Temperature: Not Applicable Other Data:Viscosity: Heavy bodied VOC Content: When applied as directed,per SCAQMD Rule 1168,Test Method 316A,VOC content is:<490 g/I. SECTION 10 -STABILITY AND REACTIVITY Stability: Stable Hazardous decomposition products: None in normal use. When forced to burn,this product gives off oxides of carbon,hydrogen chloride and smoke. Conditions to avoid: Keep away from heat,sparks,open flame and other ignition sources. Incompatible Materials: Oxidizers,strong acids and bases,amines,ammonia SECTION 11 -TOXICOLOGICAL INFORMATION Toxicity: LD50 LC50 Target Organs Tetrahydrofuran(THF) Oral:2842 mg/kg(rat) Inhalation 3 hrs.21,000 mg/m3(rat) STOT SE3 Methyl Ethyl Ketone(MEK) Oral:2737 mg/kg(rat),Dermal:6480 mg/kg(rabbit) Inhalation 8 hrs.23,500 mg/m3(rat) STOT SE3 Cyclohexanone Oral:1535 mg/kg(rat),Dermal:948 mg/kg(rabbit) Inhalation 4 hrs.8,000 PPM(rat) Acetone Oral:5800 mg/kg(rat) Inhalation 50,100 mg/m3(rat) STOT SE3 Reproductive Effects Teratogenicity Mutagenicitv Embryotoxicity Sensitization to Product Synergistic Products Not Established Not Established Not Established Not Established Not Established Not Established SECTION 12 -ECOLOGICAL INFORMATION Ecotoxicity: None Known Mobility: In normal use,emission of volatile organic compounds(VOC's)to the air takes place,typically at a rate of<490g/I. Degradability: Biodegradable Bioaccumulation: Minimal to none. SECTION 13 -WASTE DISPOSAL CONSIDERATIONS Follow local and national regulations. Consult disposal expert. SECTION 14 -TRANSPORT INFORMATION Proper Shipping Name: Adhesives Hazard Class: 3 EXCEPTION for Ground Shipping Secondary Risk: None DOT Limited Quantity: Up to 1 L per inner packaging,30 kg gross weight per package. Identification Number: UN 1133 Consumer Commodity:Depending on packaging,these quantities may qualify under DOT as"ORM-D" Packing Group: PG II Label Required: Class 3 Flammable Liquid TOG INFORMATION Marine Pollutant: NO TDG CLASS: FLAMMABLE LIQUID 3 SHIPPING NAME: ADHESIVES UN NUMBER/PACKING GROUP: UN 1133,PG II SECTION 15 -REGULATORY INFORMATION Precautionary Label Information: Highly Flammable,Irritant Ingredient Listings: USA TSCA,Europe EINECS,Canada DSL,Australia Symbols: F,Xi AILS,Korea ECL/TCCL,Japan MITI(ENCS)CA Prop65- Cancer Risk Phrases: R11:Highly flammable. R66:Repeated exposure may cause skin dryness or cracking R36/37:Irritating to eyes and respiratory system. R67:Vapors may cause drowsiness and dizziness S25:Avoid contact with eyes Safety Phrases: S2:Keep out of the reach of children S26:In case of contact with eyes,rinse immediately with plenty of water and seek medical advice. S9:Keep container in a well-ventilated place. S33:Take precautionary measures against static discharges. S16:Keep away from sources of ignition-No smoking. SECTION 16 -OTHER INFORMATION Specification Information: Department issuing data sheet: Environmental Health&Safety All ingredients are compliant with the requirements of the European E-mail address: EHSlnfo@SpearsMfg.net Directive on RoHS(Restriction of Hazardous Substances). Training necessary: Yes,training in practices and procedures contained in product literature. Reissue date/reason for reissue: 01/17/24/Updated GHS Standard Format Intended Use of Product: Solvent Cement for CPVC Plastic Pipe This product is intended for use by skilled individuals at their own risk.The information contained herein is based on data considered accurate based on current state of knowledge and experience.However,no warranty is expressed or implied regarding the accuracy of this data or the results to be obtained from the use thereof. Page 2 of 2 FS5-6-0124 ASC / Engineered Solutions Fig. 186 Two Hole Pipe Strap (Formerly Afcon Fig. 510) Size Range:3/4"through 3" Material:Carbon Steel Finish: Pre-Galvanized per ASTMA653 Service:Hanger for CPVC,steel,&copper pipe in the horizontal position on the bottom and side 4 of structural wood beams,composite beams and Steel20 Ga.(min.)(Fig.A,C respectively).Can be al us used as a restrainer when installed on top of structural wood beams(Fig.B),for limiting pipe usrED movement due to thrust loads during sprinkler system start-up.It can also be used as a guide to limit movement for pipe in the vertical position.When used on composite wood beams,web thickness must be 3/8"or greater. Approvals:cULus Listed t Installation: • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. • Do not make adjustments to hanger mounting flanges that result in clamping the pipe to the mounting surface.Pipe must be allowed to move freely through hanger. • Steel applications require two(2)#14 x T'hex washer head self-drilling TEK screws.Not Supplied.Part Number STD-0090. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface. Easily attaches to wood structure with#10 x T'hex washer head self threading screw supplied with product.No pre-drilling required. Retaining dimples hold the strap onto the pipe for ease of installation.(Not shown). Ordering:Specify pipe size,figure number,and description. E f — A mC \ < , 7114\ I Fig.A Fig.B Fig.C Fig.186:Dimensions(in)•Weight(lbs) Approx. Pipe Size A B 0C E F Weight/100(lbs) 3/4 1 213/16 11A 5 1 11/4 31/4 11/2 6 1'A 16/16 33/8 TA 111/16 7 11/2 19/16 31/8 1/4 21A 8 2 113/16 46/16 29/16 9 21/2 21/4 58/8 21/8 14 13/16 3 21/8 66h6 31/2 17 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-3.19 page 1 SS-SUB-186-0120230424 Pipe Hangers ♦ Supports AS C )S, Engineered Solutions Two Hole Standoff Hanger and Restrainer Fig. 188R (Formerly Afcon Fig. 514) Size Range:W'through 2" Material:Carbon Steel �, f Finish:Pre-Galvanized per ASTMA653 Service: • Hanger and surge restraint for horizontal CPVC,steel,and copper piping when �' ;;Y��I� installed on the top,bottom,and side of the supporting structure. P PP g • Guide for vertical CPVC,steel,and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. � •�, ����, � +��,� • May be installed with concrete,steel structural members,and other structural members with fasteners which comply with the requirements of NFPA 13. C Ills Approvals:cULus Listed Patents:No.6,648,278 61SfEU Installation: Snap hanger over pipe.If needed,squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eLiminates0A 0 , Easily attaches to wood structure with#10 x T'hex washer head self-threading screw supQ;+edl iifli.glow C:;; Z.. '- No pre-drilling required. • Bottom of pipe is offset T/2"from the structure.Eliminates wooden spacer blocks. Ordering:Specify CPVC pipe size,figure number and description. Hanger& Restrainer 77 11� 1.50 }3 J Hanger& Guide& 11/ Restrainer O Restrainer r r �I :. Installation-Backing Nut Hanger=1-At top fastener Restraint=2-On each fastener Per NFPA-13D and NFPA-13R ANVIL An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: s5-9.18 page 1 SS-SUB-188R-v0120220629 I U Z�O ASC Pipe Hangers & Supports WJF V.. .j Engineered Solutions Two Hole Standoff Hanger and Restrainer (cont.) Fig. 188R (Formerly Afcon Fig. 514) ° ° a B a d A d a ° d ° a as d .d ° E 0 + 0c d ° d d C d d d � dQQ d d Q Q d. F D G Hanger and Restrainer Fig.188R:Dimensions(in)•Weight(lbs) CPVC Max.Hanger Approx. Pipe Size A B 0C D E F G Spacing(ft) Weight/100(Lbs) 'A 28/4 31/2 1/4 2 1 21/8 Th 551/2 11 1 213/16 31/2 1/4 23/16 1 2"/16 Th 6 12 TA 213/16 31/2 'A 26/6 1 31/4 11/2 61/2 13 Th 36/8 41/4 1/4 2716 1 31/2 Th 7 14 2 Y/16 4% 1/4 211/16 1 4 Th 8 16 Fig.188R:Listed Fasteners Pipe Wood and Composite Beams Steel(18ga.Minimum) CPVC Screw Supplied or#10 x T'TEK Screw #14 x 1"TEK Screw or 1/d'x T'TEK Screw Steel&Copper #14 x 1"TEK Screw or 1/4'x 11/2"Lag Screw #14 x 1"TEK Screw or 1/4'x 1"TEK Screw '0 ANVI L. '44UP' An ASC Engineered Solution SS-9.18 page 2 SS-SUB-188R-v0120220629 Pipe • ♦ Supports 'k) / Engineered Solutions Two Hole 900 Side Mount Strap Fig. 187 (Formerly Afcon Fig. 511) Size Range:3/a'through 2" Material:Carbon Steel I Finish: Pre-Galvanized per ASTM A653 G Service:Hanger for CPVC pipe in the horizontal position on the bottom of structural wood beams and Steel20 Ga.(min.)(Fig.A).Can be used as a restrainer,only in Steel20 Ga.(min)(Fig.B). During installation,adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger,minimizing vertical pipe movement. j Approvals:ULand ULC Listed. ) Installation • Snap hanger over pipe. Secure hanger to mounting surface with screws provided. i Do not anchor tightly to mounting surface.Pipe must be allowed to move freely through hanger. Steel applications require two(2)#14 x T'hex washer head self-drilling TEK screws. Not Supplied.Part Number STD-0090. c @us Features: LISTED • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with#10 x 1"hex washer head self threading screw supplied with product. No pre-drilling required. Ordering:Specify CPVC pipe size,figure number and description. A — OC — - B F . V I- E Fig.A Fig.B Fig.187:Dimensions(in)•Weight(lbs) CPVC A B 0C E F Max.Hanger Approx. Pipe Size Spacing(ft.) Weight/100(lbs) 3/4 16/16 11/2 3/16 13/16 21/2 51/2 5 1 1 19/16 3/16 13/16 23/4 6 6 11/4 VA6 1'A 3/16 13/16 31/4 61/2 7 Th VA6 111/16 3/16 13/16 31/2 7 8 2 19/16 21/8 3/16 13/16 313/1fi 8 9 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-11.19 page 1 SS-SUB-187-v0120230424 RESIDENTIAL&COMMERCIAL FIRE PUMP SPECIALISTS 6040 NE 11—ITH AVE. PORTLAND,OR 9722#3 S -878-8055 WWW.TALC0FIRE.CC_%M t' ,WTALCO ... , 00 HOME HYDRANT NFPA-1 3D Packaged Residential Fire Pump & Tank U.S. Patents #8,678,032 & 8,905,069 H H 150S P 29 r .:. PAM 350 Gallon Water Tank J) Tank Drain !/"q 2 '(GHT) sir) Overflow Fitting 1 "(FNPT) I) Auto-Fill Valve �/�"(FNPT A - r. "J 1 .5HP Electric Motor 240 Volt Single-Phase '10.9 Amp (Full Load) iV- �A 1 Discharge (FNP'T) 77 - ��� Strad Riser Control System Isolation Ball Valve k 05, Test Line/System Drain ') Pressure Gauge 41 (73 Flow Switch (Optional) rl �, (;') .PresSLire Switch Cq) Run-Time Controller Discharge Check Valve Suction Shut-off Valve 49 PerformancePerformance vaiaaE t-,aserlon multiple pump testy .Not for cerldficabon pljrj�osqS A-s �30 35 PM 0 1- 20 25 : 40 45 50 PSI 55 52 51 50 148 46 4�3- 40 O & M INSTRUCTION MANUAL HOME HYDRANT. TALCO FIRE SYSTEMS U.S. PATENTS 48,678,033 8 4899059069 OVERALL VIEW OF HOME HYDRANT SHUT-OFF VALVE TEST VALVE PRESSURE GAUGE FLOW SWITCH (OPTIONAL) PRESSURE SWITCH CONTROLBOX CHECK VALVE HOME HVDRAN TEST CONNECTION AUTOMATIC FILL VALVE TANK DRAIN SUCTION VALVE 2 IMPORTANT SAFETY INFORMATION THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE UNIT. UNIT NOT DESIGNED FOR USE WITH HAZARDOUS LIQUIDS OR FLAMMABLE GASES. THESE CAN CAUSE FIRE, BURNS, DAMAGE, OR FATALITIES. To avoid serious or fatal injury, or major property damage, read and follow all safety instructions in this manual and on the product. The following SAFETY SYMBOLS in the manual or on the product warn of HAZARDS that can cause fatality, personal injury, or property damage as described below. �& Warns of ELECTRICAL HAZARDS that can cause fatality, serious personal injury, or major property damage. CAUTION Warns of NON-ELECTRICAL HAZARDS that can cause personal injury or property damage. Warns of common installation mistakes. This symbol may denote both ELECTRICAL HAZARDS i� and NON-ELECTRICAL HAZARDS. 3 Preparation: 1.1 Inspect unit for damage. Report damage to carrier or distributor immediately. CAUTION 1.2 When moving the unit over rough or uneven surfaces it is recommended that the unit is carefully laid on its back, pump and piping facing upwards. Using ratcheting straps, or other similar straps, wrap them around the indentations on each end of the tank. On the four corners at each ratcheting strap pass a rope or strap under the ratcheting strap and tie it in a loop to make a lifting handle. Ensure the ratcheting straps are tight so they do not slip off the tank during the moving operation. Use a pipe or 2x4 passed through the loop to pick unit up to move it. (see example pictures on previous page) A 1.3 Electrical supply must be a separate branch circuit with fuses or circuit breakers, wire sizes, etc. per national and local electrical codes. Adhere to all applicable laws, standards, and codes when wiring. Installation by a licensed electrical contractor is recommended. 1.4 The TALCO Home Hydrant must be installed in such a manner that the tank is readily accessible for regular maintenance or replacement in case of tank failure. Do not install the unit in a manner that requires removal of any wall or portion of the structure. 1.4.1 TALCO FIRE SYSTEMS will not be held liable for any cost that may incur due to removal or replacement of walls, doors, etc. in order to replace the tank or any equipment that may require service or replacement, or fail while in service due to improper installation; including, but not limited to, installation in an unprotected area. CAUTION 1.5 Units shall be installed in a location that protects them from direct sunlight, inclement weather in general, and freezing temperatures in particular. Installation in a secured room is strongly recommended to prevent vandalism or tampering with control settings. Not following the guidelines above may cause the unit to malfunction or fail prematurely. A&1.5.1 Home Hydrant systems are not designed for unprotected outdoor installation. CAUTION 1.6 It is imperative that the surface the Home Hydrant is installed on is capable of supporting the weight of the unit when full of water, and is level and solid in nature. Do not install the unit on gravel, dirt, grass, or other substrates which may shift or contain materials which may puncture the tank. 1.6.1 Fresh water weighs approximately 8.34 pounds per gallon. Use caution when deciding where to place a Home Hydrant. Never attempt to move a unit that is full of water. 5 Talco Home Hydrant Wiring Diagram 230V, 1-Phase supply w/ Ground E 12 BLACK L1 T1 Mi 1.3 RED L2 T2e L2 :.. ..:.....::..::• PUMP 1.4 T 7 VAC 10 1 Pump Connection JAMPMAX 1.5 (Connect to motor contactor as shown) 1.6 BROWN 2 3 I DELAY ON BREAK PT TIMER # ABB KSDB611505 PS 6 1.7 ;` WHITE 1.8 HAND MOTOR 9 OFF M1 CONTACTOR ONTA TOR1. 10-80 2 1.- AUTO 1 Al A2 PT 1.10 1.11 1.12 Pressure switch is factory wired. 1.13 Do not modify. Field connections inside main controller. 1.14 1.15 116 1.17 1.18 AUTO - \ OFF HA!' 6 1.19 e � 1.20 1.21 C i 1.22 . 1.23 1.24 EDW-WD-OEM-3 JaMod .•rm Rev.2.0 @ 6119107 1.25 16 FIRE SPRINKLER PERMIT APPLICATION For Instruction/Checklist,please click here Site Address: 18304 Cedarbough Loop Project Name: I Weikianos AFH Project Valuation: $11,000 Preferred Contact: O Owner Applicant Contractor Project Description: i Owner Details Owner Name: I Weikianos Dessalgn Office No.: 206-596-1779 Email Address: weikidessalgn@gmail.com Cell No.: 206-596-1779 Mailing Address: 118304 Cedarbough Loop City: Arlington State: I WA Zip: 198223 Contractor Details Contractor Name: I Raven Fire Protection Office No.: 253-387-1090 Email Address: info@ravenfp.com Cell No.: 253-576-2314 Mailing Address: 13204 Crystal Ridge Dr SE City: Puyallup State: WA Zip: 198372 L&I Contractor License Number: I RAVENFP750-PN Expiration Date: 10/15/2027 Primary Contact Information First Name I Ira Last Name Potter Email Address I ipotter@ravenfp.com O TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ E:::— 3to5 $ 125.00 = $ � 6to 10 $ 175.00 = $ � 11 to20 $ 225.00 = $ � 21 to 40 $300.00 = $ 41 to 100 $375.00 11 = $ 101 to 200 $475.00 11 = $ 201 to 300 $575.00 IF-= $ > 300 $600.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $600.00 + $ $ Hydraulically Designed Systems Yes O /No ❑ Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ❑ IF NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $ 375.00 — $ 101 to 200 $ 475.00 = $ 201 to 300 $ 600.00 — $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ Hydraulically Designed Systems Yes O / ❑ No Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ OIF RESIDENTIAL(NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $ 175.00 = $ 175 11 to 25 $ 225.00 — $ 26+ $ 275.00 — $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ *NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% _ $ PERMIT FEE SUBTOTAL $ O HOOD SUPPRESSION SYSTEM Type of System Cost per Unit Subtotal Pre-Engineered $ 200.00 — $ Custom Engineered $ 275.00 — $ 26+ $ 275.00 — $ > 300 F $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ *NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ HOOD SUPPRESSION SYSTEM Type of System No. of Unit Cost per Unit Subtotal Pre-Engineered x $ 200.00 — $ Custom Engineered l X $ 275.00 $ PERMIT FEE SUBTOTAL $ STANDPIPE SYSTEM Standpipe Type of No. of Unit Cost per Unit Subtotal Class I—new or existing x $ 150.00 — $ Class II—new or existing x $ 150.00 — $ PERMIT FEE $ SUBTOTAL FIRE PUMP Type of FIRE No. of Unit Cost per Unit Subtotal PUMP Fire PUMP $ 300.00 — $ x PERMIT FEE $ SUBTOTAL SPRAY BOOTHS (105.7) & INDUSTRIAL OVENS (105.7.7) NOTE: SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Unit Cost per Unit Subtotal Pre-Engineered _ $ 150.00 — $ w/documents x Site-built or used w/o $ 250.00 — $ documents x Industrial Oven $ 250.00 — $ x PERMIT FEE $ SUBTOTAL Plan review fee due at time of submittal TOTAL PERMIT FEE 1 $ 175 PLAN REVIEW FEE $ 200 Processing/Technology Fee $25.00 TOTAL $ 400 I hereby certify that I am the O Owner Applicant Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Print Name: Ira Potter Date: 04/06/2026 4rtk( tot( WASHINGTON Permit Information - - , 1 'nformat;^ Permit# 26-0266 Parcel # 00738500402400 Building ID Location 18304 CEDARBOUGH LOOP Permit Type Fire Permit Use Fire Sprinkler Zone Permit # Subdivision Applicant Name Ira Potter Address 3204 Crystal Ridge Dr SE Applicant Email ipotter@ravenfp.com Phone 2535762314 Cell Owner Name Weikianos Dessalgn Address 18304 Cedarbough Loop Owner Email weikidessalgn@gmail.com Phone 206 370 4633 Cell 206-596-1779 Contractor Raven Fire Protection Address 3204 Crystal Ridge Dr SE Contractor Email info@ravenfp.com Phone Cell 253-576-2314 Property Information Type/Improveme Accessory/Struct nt ure Current Use Proposed Use Current Zoning 0 Proposed Zoning Project Cost 11000 Project Value 11000 Current Use And Uploaded to laserfiche- Installation of a new NFPA 13D sprinkler system composed primarily of CPVC pipe and Proposed fittings. 20 sprinkler heads total. Changes Lot Width Lot Depth Map Number Total Area of Building & Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions/ Variances @ Community Development Online Portal Page 1 of 6 July 15, 2026 02:04PM WASHINGTON Structure Information Structure Type # of Stories Usable Floor Area (Sq Ft) Structure Height # of Units Load per Floor (Lbs) Sign Dimensions # of Bedrooms # of Bathrooms Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth Material Foundation Information Setbacks Front& 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width # of Off Street # of Off Street Parking Loading Miscellaneous Information ©Community Development Online Portal Page 2 of 6 July 15, 2026 02:04PM WASHINGTON Contractors License # Business Name Type Contact RAVENFP750PN Raven Fire Protection General Contractor Ira Potter ©Community Development Online Portal Page 3 of 6 July 15,2026 02:04PM WASHINGTON Inspections Inspection # Inspection Type Status Date Inspector 26-0331 Fire -Other Incomplete May 19, 2026 Kevin Olander 26-0335 Fire -Aboveground Pass May 20, 2026 Kevin Olander Cover ©Community Development Online Portal Page 4 of 6 July 15,2026 02:04PM 4rtk( tot( WASHINGTON Contacts Contact Name Type Project Address Phone Weikianos Dessalgn Owner 18304 Cedarbough Loop 206 370 4633 Raven Fire Protection Contractor 3204 Crystal Ridge Dr Se, 253-387-1090 Puyallup, WA 98372 Raven Fire Protection Others 3204 Crystal Ridge Dr Se, 253-387-1090 Puyallup, WA 98372 Ira Potter Applicant 3204 Crystal Ridge Dr SE 253-576-2314 ©Community Development Online Portal Page 5 of 6 July 15, 2026 02:04PM 4rtk( tot( WASHINGTON Fees Fee Type Date Debit Credit Balance Permit Fees April 7, 2026 $200.00 $200.00 $200.00 $0.00 $200.00 $-200.00 T O T A L $200.00 $400.00 $-200.00 ©Community Development Online Portal Page 6 of 6 July 15, 2026 02:04PM City of Arlington 14 (11 (0/1 18204 59th Avenue NE, Arlington, • • Washington 98223 Phone: 360-403-3551 jNG� WASHINGTON C Invoice Number: 26-0450 INVOICE Invoice Date: May 1, 2026 Account Number: 2852737731 Bill To: Invoice Questions? Ira Potter Phone: 360-403-3551 3204 Crystal Ridge Dr SE Email: ced@arlingtonwa.gov Invoice Due Date: May 1, 2026 Record Number: Permit A26-0266 Parcel Number: 00738500402400 Location: 18304 CEDARBOUGH LOOP Date Description Paid Date Amount Paid Balance April 7, 2026 Processing/Technology(320.341.43.00.02) $25.00 May 1, 2026 Fire Sprinkler Residential System(006.322.10.00.01) $175.00 TOTAL: Permit Fees $200.00 $200.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by May 1, 2026 Number Number This Invoice 26-0450 2852737731 1$200.00 Ira Potter 3204 Crystal Ridge Dr SE TY O City of Arlington 18204 59th Avenue NE, Arlington, • • 1114r(" too Washington 98223 Phone: 360-403-3551 1 G,�0 WASHINGTON N Invoice Number: 26-0352 INVOICE Invoice Date: April 7, 2026 Account Number: 2852737731 Bill To: Invoice Questions? Ira Potter Phone: 360-403-3551 3204 Crystal Ridge Dr SE Email: ced@arlingtonwa.gov Invoice Due Date: April 7, 2026 Record Number: Permit A26-0266 Parcel Number: 00738500402400 Location: 18304 CEDARBOUGH LOOP Date Description Paid Date Amount Paid Balance April 7, 2026 Fire System Plan Review(006.345.83.00.02) $200.00 TOTAL: Permit Fees $200.00 $200.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by April 7, 2026 Number Numb This Number Invoice 26-0352 2852737731 1$200.00 Ira Potter 3204 Crystal Ridge Dr SE WASHINGTON Permit #26-0266 Location:18304 CEDARBOUGH LOOP Routing Details ✓ Department: Permit Tech Intake Review - Approved: April 13, 2026 - Status: Approved Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at April 7, 2026 10:47AM Status: Pending Activity Type: Application Sent Hello, The City of Arlington requires any contractor working within City limits obtain a business license. Please log in to your Department of Revenue account and add the City of Arlington as an endorsement. If your business is located outside of city limits, you will add a Non-Resident City of Arlington endorsement. https:Hdor.wa.gov/manage-business/city-endorsements/arlington Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at April 7, 2026 10:48AM Status: Pending Activity Type: Pending Payment Hello, Your invoice for the plan review fee is now ready for payment. Plan review fees are due at time of submittal and prior to processing for review.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment for prompt processing of your submittal. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at April 13, 2026 04:22PM Status: Approved @ Community Development Online Portal Page 1 of 5 July 15, 2026 02:06PM liptiot tot( WASHINGTON Activity Type: Application Sent Application is ready for review. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 ✓ Department: Permit Tech Final Approval - Approved: July 15, 2026 - Status: Closed Manual Update- Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at April 7, 2026 10:38AM Status: In Progress Activity Type: Documents Review The following permit has been updated manually. Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at April 30, 2026 03:06PM Status: In Progress Activity Type: In Review CC: 1st Review Fire (Department) Application is ready for review. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at May 1, 2026 02:11PM Status: Pending Activity Type: Pending Payment Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment and I'll provide a copy of your issued permit and approved documents. @ Community Development Online Portal Page 2 of 5 July 15, 2026 02:06PM 4rtk( tot( WASHINGTON Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at May 4, 2026 09:59AM Status: Approved Activity Type: Application Sent Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Permit #26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at May 4, 2026 10:01AM Status: Approved Activity Type: Permit Issued Hello, Please find attached the issued building permit. Please review any conditions and reach out should you have any questions. Inspection request instructions can be found on the permit. Admin - Hannah Hardwick City of Arlington Fire Permit Technician II hhardwick@arlingtonwa.gov 360-403-3549 Manual Closure - Permit#26-0266 Location:18304 CEDARBOUGH LOOP- by Admin - Hannah Hardwick- Fire Permit Technician II at July 15, 2026 02:04PM Status: Closed Activity Type: Documents Review The following permit has been closed manually. Permit#26-0266 Location:18304 CEDARBOUGH LOOP ✓ Department: 1st Review Building - Approved: April 30, 2026 - Status: Approved Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Kevin Olander- Building Official at April 30, 2026 03:04PM Status: Approved Activity Type: Application Sent Kevin Olander City of Arlington Building Official kolander@arlingtonwa.gov 3604033433 ©Community Development Online Portal Page 3 of 5 July 15, 2026 02:06PM 4rtk( tot( WASHINGTON ✓ Department: 1st Review Fire - Approved: May 1, 2026 - Status: Approved Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP- by Steve Goforth -Assistant Chief/Community Risk Reduction at May 1, 2026 12:05PM Status: Approved Activity Type: Application Sent NCRFA Approved Steve Goforth North County Regional Fire Authority Assistant Chief/Community Risk Reduction sgoforth@northcountyfireems.com 360-629-2184 @ Community Development Online Portal Page 4 of 5 July 15, 2026 02:06PM 4rtk( tot( WASHINGTON Record Actions New Permit Application #A26-0266 Location: 18304 CEDARBOUGH LOOP By Admin - Hannah Hardwick- Fire Permit Technician II at April 7, 2026 10:33AM Hello, A new permit application has been submitted for review. Please login to your CIVICGov Web Application account and visit the link below to view the permit details. https://www.civicgov4.com/wa_arlington/permits/details/394 If you cannot click on the link above, please copy and paste the entire link in the browser address bar. Sincerely, CIVICGov Team. Manual Update- Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP By Admin - Hannah Hardwick- Fire Permit Technician II at April 7, 2026 10:38AM The following permit has been updated manually. Permit Application #A26-0266 Location:18304 CEDARBOUGH LOOP Condition #1 Added By Admin - Hannah Hardwick- Fire Permit Technician II at May 4, 2026 09:59AM Condition: Adhere to approved plans. Condition #2 Added By Admin - Hannah Hardwick- Fire Permit Technician II at May 4, 2026 09:59AM Condition: Permit shall be onsite for inspections. Condition #3 Added By Admin - Hannah Hardwick- Fire Permit Technician II at May 4, 2026 10:00AM Condition: Call for inspections. Inspection #26-0331: Result- Incomplete By Kevin Olander- Building Official at May 19, 2026 11:02AM Fire-Other Inspection #26-0331: Result- Incomplete Onsite contact is Ira Potter 253-576-2314, Cover Bucket Inspection. Inspection #26-0335: Result- Pass By Kevin Olander- Building Official at May 20, 2026 04:41PM Fire-Aboveground Cover Inspection #26-0335: Result- Pass On-site contact is Alex 253-883-7354. Scheduled for 10 AM. Manual Closure - Permit#26-0266 Location:18304 CEDARBOUGH LOOP By Admin - Hannah Hardwick- Fire Permit Technician II at July 15, 2026 02:04PM The following permit has been closed manually. Permit#26-0266 Location:18304 CEDARBOUGH LOOP ©Community Development Online Portal Page 5 of 5 July 15, 2026 02:06PM 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Fire - Fire Sprinkler Permit Parcel:00738500402400 Permit#:26-0266 Permit Address:18304 CEDARBOUGH LOOP Date Issued:May 4,2026 Description of Work:Installation of a new NFPA PERMIT EXPIRES 180 DAYS 13D sprinkler system composed primarily of CPVC AFTER DATE OF ISSUANCE. pipe and fittings.20 sprinkler heads total. Valuation:$11000 Code Year:2021 OWNER APPLICANT CONTRACTOR Weikianos Dessalgn Ira Potter Raven Fire Protection 18304 Cedarbough Loop 3204 Crystal Ridge Dr SE 3204 Crystal Ridge Dr SE 206 370 4633 2535762314 info@ravenfp.com weikidessalgn@gmail.com ipotter@ravenfp.com registration number PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved plans. 2.) Permit shall be onsite for inspections. 3.) Call for inspections. INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance April 7, 2026 ProcessingfIechnology(320.341.43.00.02) $25.00 April 7, 2026 Fire System Plan Review(006.345.83.00.02) $200.00 May 1, 2026 Fire Sprinkler Residential System(006.322.10.00.01) $175.00 TOTAL: Permit Fees $400.00 $400.00 Credit/Debit Card 521 Payment Successful April 12, 2026 $200.00 $200.00 Credit/Debit Card 619 Payment Successful May 2, 2026 $200.00 $0.00 NOTE: SCOPE OF WORK: SPRAY FOAM INSULATION 2 x DIAMETER OF THE RA CREWS 1/3 DEPTH E N SHALL HAVE NO CONTACT FOUR#10 x 1%" LARGEST HOLE(MINIMUM) THIS PROJECT WILL CONSIST OF THE INSTALLATION OF A NEW RESIDENTIAL ROOF SHEATHING WITH CPVC PIPING. SHEET METAL SPRINKLER SYSTEM.POINT OF CONNECTION WILL BEAT THE DISCHARGE VALVE OF S ———— ALLOWED HOLE ZONE THE TALCO HH3 TANK/PUMP SYSTEM, EXCLUSIONS: FIRE PROTECTION FIG.511 — — HANGER I PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT 2"PIPE, 1 n2-3' MAXIMUM ELECTRICAL WIRING OF ANY KIND,INC LUDING BUT NOT LIMITED TO WATER FLOW 3204 Crystal Ridge Dr SE SWITCH,ELECTRIC BELL,AND TAMPER SWITCH / Puyallup,WA 98372 CENTRALSTATION MONITORING EQUIPMENT,WIRING AND SERVICES 2xDIAMETERMI THE Phone:253-387-109 7-1090 CPVC PIPING LVLAND PSL LARGEST HOLE(MINIMUM) ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO:BACKFILL,SELECT FILL, BATT INSULATION INSTALLATION REQUIREMENTS:STAPLE LSL HOLE ZONE HOLEZONE 1/3 DEPTH BREAKING PATCHING,SAW CUTTING,LAWN REPAIR,LANDSCAPING,TREE REMOVAL, www.ravenfp.com BATTS A MINIMUM OF EVERY SIN.WHERE JOISTWIDTHS / STERILIZATION,DEVELOPMENT FEES AND CITY CONNECTION. LIC#RAVENFP750PN EXCEED Fr.,EXTEND INSULATION 2 FT ON BOTH SIDES O THE WATER-FILLED PIPE.EXTEND INSULATION 6 IN.FROM ROOF RAFTERS CLOSED CELL SPRAY FOAM ROOF RAFTERS d —— —— GENERAL NOTES: —— —— THE ENDS OF THE WATER-FILLED PIPE.WHERE MULTIPLE INSULATION ABOVE CPVC PIPING ' 1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. LAYERS OF BATT INSULATION ARE INSTALLED,IT IS MOST .............................. EFFECTIVE TO CROSS-LINK BATTS TO COVER GAPS. LVLAND PSL w�axlMurox ar-T AL OWED HOLEZ NE 2. HEATTO BE PROVIDED BYTHE OWNER ATALLTIMES FOR WET TYPE SPRINKLER eexrlFle�reoFCOMFere d A SYSTEMS. ' FIRE a.IRKLERa TEMSRC LSL ALLOWED HOLE ZONE 3. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIREPROTECTION SYSTEM AT CLOSED CELL INSULATION AT ROOF CPVC,STEEL-HANGER FIG.511 ALLOWED HOLE ZONE OR ANY APEDKEENANCESTHEREOF. ��a"•""np s m� ATTIC INSULATION DETAIL NI i 4. ALL PI PE TO BE CPVC U.N.O. ---�5 0a/04I2026 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF SS S4 FT.AND LESS �.......�..'r ..........R"'.....i (NFPA 13D 2019 8.3.2). FIG.514 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, HANGER AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: (2) 'HEX HANGERS-PIPE HANGERS SHALL BE SIZED,SPACED AND INSTALLED 1 THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ FT TRUSS BTM CHORD HEADSCREWS AS ) UNFACED REQUIRED BY NFPA STANDARDS. 2)THE WALLS AND CEILING ARE SURFACED WITH NONCOMBUSTIBLE OR FIBERGLASS -NO OTHER PIPING ANDIOR DEVICES ARE TO BE ATTACHED TO THE LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN EPA 220.(NFPA 13D 2019) BATT INSULATION SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN PIPE BACKING NUT 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES, FIG.29 _ SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. CARPORTS,AND SIMILAR STRUCTURES.(NFPA 13D 2019) HANGER� 1 -THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. PENTHOUSE EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED •'•� -SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT USED FOR THIS INSTALLATION. VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS,CRAWL CPVC PIPE \ NFPA 13(2010)TABLE 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED (2)5l16"HEX \LX (R-In) FOR LIVING PURPOSES.(NFPA 13D 2019) HEADSCREWS 9. SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS(REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR ACCESSED FROM OUTDOORS WHERE THE PIPE TYPE NOMINAL PIPE SIZE(IN-)J/ CLOSETDOES NOT HAVE A DOOR OR UNPROTECTED PENETRATIONS DIRECTLY PIPE \ INTO THE DWELLING UNIT.(NFPA 13D 2019) CPVC BTM CHORD OF TRUSS 1 1/ 1A 2 2% 3 5-6 6-0 6-6 7-0 5-0 9-0 10-0 10. AMAIN DRAIN ISTO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH (2)5l16"HEX (2)5/16"HEX NFPA 13D 2019.HUB-DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. HEADSCREWS HEADSCREWS 11, NO GYP,BD.CEILINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL TENTING OVER CPVC PIPING EATON INSPECTION IS COMPLETE. CPVC,STEEL-HANGER FIG 29 CPVC,STEEL-HANGER FIG.514 PIPE HANGERS SPACING 12. MAXIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 16'X16'.MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14'X14'.MAXIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 16'X20'.U.N.O. INSTALLATION AND HANGER DETAILS 13, MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-DO.C.MINIMUM DRY SIDEWALL SPRINKLER SPACING 6-OO.C'.MINIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 8-OO.C. 14. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D 2019 15. PIPE SHALL BE REQUIRED TO REMAIN ON A 2/,"CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES, 16. IT5.6.1)SPRINKLERS INSTALLED WHERE MAXIMUM AMBIENT CEILING TEMPERATURES DO NOT EXCEED 100 DEGREES FAHRENHEIT SHALL BE ORDINARY TEMPERATURE-RATED OF INTERMEDIATE TEMPERATURE RATED SPRINKLERS THROUGHOUT UNLESS MODIFIED BY REQUIREMENTS OF 7.5.6.3 WATER SUPPLY INFORMATION: WATER SUPPLY INFORMATION IS PER PUMP AND TANK MANUFACTURER DATA ATALCO FIRE SYSTEMS (E)BEDROOM B CL (E)BEDROOM C (E)LIVING W&D HALL (N)BEDROOM D HOME HYDRANT HH3-150SP 2 ® 350 Gallon Water Tank ill�sor 1)Tank D2in�"(OHT) _ Iq ewtt ®OverRow Fitting 1"(FNPT) Q3 Auto-Fill Valve a"(FNFr ® Revisions 1.51HP Electric MotorIs 240 Volt Single-Phase 10.9 Amp(Full Load) -� BUILDING SECTION"A" 1/4"=1'-0e smartlftlserr11(Fo Sys mm 77 © Contract Name: (44)Isolation Bell Valve I o Weikainos Adult ®Test Line/System Drain 0 2' 4' 6' aPressureGauge ® Family Home 1/4"GRAPHIC SCALE � (Optional)Flow Switch(a)Pressure Switch 11 9 Run-Time Controller Discharge Check Valve y 1 7 , Suction Shut-off Valve Approved 49 - Performance ' 1 Steve Goforth,Fire Marshal GPM 0 20 25 30 35�40 45b 50 18304 Cedarbough Lp Subject to Field Review I PSI 155 52 51 50 48 46 43 1 40 Arlington,WA 98223 05/01/2026 12:01:36 PM Drawing Title FIRE SPRINKLER PLAN Date: 04/04/2026 Job Number: 10-0015 Designer: C.Pleasant S P R I N K L E R S U M M A R Y S Y S T E M D E S I G N C R I T E R I A PARCEL# 00738500402400 TYPE MODEL# SIN FINISH TEMP. ORIFICE K-FACTOR MAX.SO.FT. MIN.SPACING OTY. TYPE SYSTEM: X❑WET ❑DRY ❑PA NFPA STANDARD: ❑#13 ❑#13R❑#13D❑X O RESIDENTIAL CONCEALED PENTENT(SENJU) RC-RES SS8464 WHITE 205' 1/2" 4.9 16'X 16' 8'-0' 21 NFPA EDITION: 2025 Drawing No. x Sprinklers-ARE-NOT required to be located in the center or quarter points of ceiling tiles. F P NO 0 01 II YV OCCUPANCY: RESIDENTIAL HAZARD: RESIDENTIAL SITE PLAN PIPE TYP E S AND FITTING TYEll] N.T.S TOTAL SPRINKLERS INSTALLED THIS PROJECT= 21 PIPING: CPVC FITTINGS: CPVC SCOPE OF WORK: THIS PROJECT WILL CONSIST OF THE INSTALLATION OF A NEW RESIDENTIAL RA EN SPRINKLER SYSTEM.POINT OF CONNECTION WILL BE AT THE DISCHARGE VALVE OF THE TALCO HH3 TANKRUMP SYSTEM. EXCLUSIONS: FIRE PROTECTION PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT (E)DECK ELECTRICAL WIRING OF ANY KIND,INC LUDING BUT NOT LIMITED TO WATER FLOW 3204CrystalRid eDrSE (E)SUNROOM SWITCH,ELECTRIC BELL,AND TAMPER SWITCH g Puyallup,WA 98372 CENTRAL STATION MONITORING EQUIPMENT,WIRING AND SERVICES Phone:253-387-1090 ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO:BACKFILL,SELECT FILL, www.ravenfp.com PATCHING,SAW CUTTING,LAWN REPAIR,LANDSCAPING,TREE REMOVAL, WWW. p.COm DN STERILIZATION,DEVELOPMENT FEES AND CITY CONNECTION. LIC#RAVEN FP750PN 8'-0" 2'-7" 6'-4" 8'-0" 2'-3^ 7'-91, 4'-4" 15'-` 8' � GENERAL NOTES: (E) 1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED, -.as�eERTIF�elTE of eo xFETEMC LIT, o 2. HEAT TO BE PROVIDED BY THE OWNER AT ALL TIMES FOR WET TYPE SPRINKLER F �x SYSTEMS. FIRE SPRINKLER SYSTEMS e (E)C 3. H R E PROTECTION CONTRACTO R SHALL NOT BE RESPONSI BEE FOR TH E AS I CITY o N OFFICE OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE PROTECTION SYSTEM ( ) O (E)KITCHEN OR ANY APPURTENANCES THEREOF ' RnvExR i 0 4. ALL PIPE TO BE CPVC U.N.O. - - 04/04I2026 E BE R M A R... °0 0 _ I ( ) ❑ 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF555O.FT.ANDLE55 R ......... (E)FA ILYROOM NUMB (NFPA13D20198.3.2). 6. SPRINKLERS SHALL NOT BE REgUIRED IN CLOTHES CLOSETS,LINEN CLOSETS, Cn AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: (E) ATH ~� 3-O ® 2)THE WALLS AND CEILING ARE SURCE DOES NOT ACDEWITH NONCOMBUSTIBLE OR I2-5 LIMITED-COMBUSTIBLE MATERIALS AS DEFINED IN FPA 220.(NFPA 13D 2019) J ~ 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES, TANK SHED °N CARPORTS,AND SIMILAR STRUCTURES.(NFPA 13D 2019) RESIDENTIAL FIRE T rC7 SETPUMP &TANK 0 Q.FT Co 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE, HH3-15OSP I -��i _ In (N)BATH --o PENTHOUSE EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED CLOSET CLOSET �' IE)PONYMUL VENTILSPACESATION TIONEQUI1)DICATED MEET,EICULI FLOOROANDCONTAINI ELEVATOR RSHAFS,DWELLIN UNIT (E) ATH 7 SQ 9 SQ U VENTI ATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS,CRAWL 1O3 1 1 0 SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED (()) 62F FOR LIVING PURPOSES.(NFPA 13D 2019) UM I I 0-8 I I 9. SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR -� 9-3 ,„w 9-7 9-4 8-D CLOSETS(REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE A DOOR OR UNPROTECTED PENETRATIONS DIRECTLY CLOSET CNA ROOM N INTO THE DWELLING UNIT.(NFPA 13D 2019) v v I cv 10 SQ.FT `" 9'-4)r 1~cv ((E)BEDROOM 10. AMAIN DRAIN LETO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH J lO2 ° NFPA 13D 2019.HUB-DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. I2 5 1 11. NO GYP.BD.CE ICINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL - (E)LI NG T """"" INSPECTION IS COMPLETE. FUR. f 12, MAXIMUM RESIDENTIAL PENDENT SPRINKLER MAXI SPACINGRESIDENTIAL DENTI'.MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14'X14'.MAXIMUM RESIDENTIAL SIDEWALL °i I���,ryl ~+ SPRINKLER SPACING I6'X20'.U.N.O. E)BEDROOM (E)BEDROO C J e�P w T 13. MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-OO.C'.MINIMUM DRY _ ILJf 1 I-l�l SIDEWALL SPRINKLER SPACING 6-00.C'.MINIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 8-OO.C. CLOSET 3 8 -7 A 10 SQ F .J 14. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D 2019 _1• g'_5y^ w g (N I BEDROOM D [j - 6 15. PIPE SHALL BE REQUIRED TO REMAIN ON A 2/"CENTERLINE ON THE TOP OF j., THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE ULU \ PRIORITY OVER OTHER TRADES. —ROBE ATT \ 16. (7.5.6.1)SPRINKLERS INSTALLED WHERE MAXIMUM AMBIENTCEILING LIT ACC. ` Co TEMPERATURES DO NOT EXCEED 100 DEGREES FAHRENHEIT SHALL BE ORDINARYTEMPERATURE-RATED OF INTERMEDIATE TEMPERATURE RATED 8-0• 6-4^�rl 2'-7` 8-D^ ` SERINKEER5 THROUGHOUT UN LESS MODIFIED BY REQUIREMENTS OF 7.5.6.3 �E PORCH �i � DIN naoRoeL - I 1 4- H� H1 (E)RAMP (N) EDROOM F (N BEDROON E REMOTE AREA 1 � ReVISIOnS Contract Name: Weikainos Adult SPRINKLER LAYOUT Family Home 1/4"=1'-0.. 0 1/42 GRAPHIC SCALE B WEIKAINOS AFH 18304 Cedarbough Lp REMOTE AREA 1 Arlington,WA 98223 HYDRAULIC CALC. INFORMATION NEW HYDRAULIC PIPE SIZES GROUND FLOOR Drawing Title NFPA 13D FIRE SPRINKLER PLAN PIPE SIZE 1' 2 HEADS HYDRAULIC DESIGN DATA 1' BRANCHLINES Hazard Class. RESIDENTIAL 1' MAIN s stem area 2t 92 SQ.FT. I' PUMP CONNECTION E""T e WET Calc'd Oansit 0.05 GPM SQ.FT. Remote Area Si- 238.2 SQ.FT. PIPE SIZES ARE BASED ON THE HYDRAULIC Covers a Per Head 256 SQ.FT. CALCULATION OF THE GROUND FLOOR REMOTE AREA. Demand 26.0 GPM® 21.3 PSI CALCULATIONS PROMDE A 29,42 PSI SAFETY FACTOR(58.0%). 0 Denotes Reference Points Date: 04/04/2026 Job Number:10-0015 Designer: C.Pleasant S P R I N K L E R S U M M A R Y S Y S T E M D E S I G N C R I T E R I A PARCEL# 00738500402400 TYPE MODEL# SIN FINISH TEMP. ORIFICE K-FACTOR MAX.SQ.FT. MIN.SPACING OTY. TYPE SYSTEM: X❑WET ❑DRY ❑PA NFPA STANDARD: ❑#13 ❑#13R❑#13D❑X O RESIDENTIAL CONCEALED PENTENT(SENJU) RC-RES SS8464 WHITE 205' 1/2^ 4.9 16'X 16' 8'-0. 21 NFPA EDITION: 2025 Drawing No. Tp Sprinklers-ARE NOT-required to be located in the center or quarter points of ceiling tile!. F P 002 YV OCCUPANCY: RESIDENTIAL HAZARD: RESIDENTIAL P I P E T Y P E S A N D F I T T I N G T Y P E S TOTAL SPRINKLERS INSTALLED THIS PAGE = 21 PIPING: CPVC FITTINGS: CPVC