HomeMy WebLinkAbout16607 Smokey Point Blvd_BLD6633_2026 i FIRE ALARM PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: 0 New Installation ❑ System Modification ❑ Phased Installation Property Address: 16607 smokey Pt Blvd,Arlington Suite No.: Project Valuation: 33191 Lot#: Parcel ID No.: 31052800204300 Preferred Contact: 71 Owner 0 Applicant 71 Contractor Project Description: Les Schwab-114015943-13 installing replacement FA system Owner Name: SFP-B LTD PTNSP Phone No.: Email Address: Cell No.: Mailing Address: PO BOX 5350 City: Bend State: OR Zip:97708-5350 Applicant Name: Johnna Lambert Phone No.: 503-201-4772 Email Address: johnna.lambert@jci.com Cell No.: 503-201-4772 Mailing Address: 7815 S. 180th Street Cit :Kent State:WA Zip:98032 Contractor Name: Johnson Controls Security Solutions, LLC phone No.: 503-201-4772 Email Address: johnna.lambert@jci.com Cell No.: 503-201-4772 Mailing Address: 7815 S. 180th Street City: Kent State: WA zip: 98032 L&I Contractor License Number: JOHNSCS7725H Expiration Date: 8/8/25 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: 0 Complete and Scaled Plans 0 Specification Sheets 0 Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ ✓❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $350.00 = $350.00 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $200.00 PERMIT FEE SUBTOTAL $550.00 PERMIT FEE TOTAL $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ l hereby certify that I am the ❑ Owner, ❑■ Applicant, ❑ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance ith the laws,rules and re ulation of the State of Washington,and the City of Arlington. Johnna Lambert 7/18/25 rto e Print Name Date REV2.2024 Page 2 of 2 DF-52417:D•B-90 ANN-80 FIre-LiTeUALarms so-Character Serial LCD Annunciator by Honeywell Annunciators General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ- ` ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, orderANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type,zone, independent point alarm,trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized , operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required,which saves time during system commissioning. Features Supervisory • Alarm Silenced • Listed to UL Standard 864,9th Edition • Backlit 80-character LCD display(20 characters x 4 lines) Specifications • Mimics all display information from the host panel Operating voltage range: 18 VDC to 28 VDC • Control switches for System Acknowledge, Signal Silence, Drill, Current consumption @ 24 VDC nominal (filtered and non- and Reset resettable):40 mA maximum • Control switches can be independently enabled or disabled at the Ambient temperature:320F to 120OF(0°C to 49°C) FACP Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± • Keyswitch enables/disables control switches and mechanically 2°C(90°F±3°F) locks annunciator enclosure 5.375" (13.65 cm.) high x 6.875" (17.46 cm.)wide x 1.375" (3.49 • Keyswitch can be enabled or disabled at the FACP cm.)deep • Enclosure supervised for tamper For use indoors in a dry location • System status LEDs for AC Power,Alarm, Trouble, Supervisory, All connections are power-limited and supervised and Alarm Silence • Local sounder can be enabled or disabled at the FACP The ANN-Bus • ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- • Displays device type identifiers, individual point alarm, trouble, IARY POWER SUPPLY supervisory,zone,and custom alpha labels The ANN-Bus can be powered by an auxiliary power supply when • Time-and date display field the maximum number of ANN-Bus devices exceeds the ANN-Bus • Surface mount directly to wall or to single, double, or 4" square power requirements. See the FACP manual for more information. electrical box ANN-BUS DEVICE ADDRESSING • Semi-flush mount to single, double, or 4" square electrical box. Each ANN-Bus device requires a unique address (ID Number) in Use ANN-SB80KIT for angled view mounting order to communicate with the FACP.A maximum of 8 devices can • Can be remotely located up to 6,000 feet (1,800 m) from the be connected to the FACP ANN-Bus communication circuit. See the panel FACP manual for more information. • Backlight turns off during AC loss to conserve battery power but WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT will turn back on if an alarm condition occurs • May be powered by 24 VDC from the host FACP or by remote The ANN-80 connects to the FACP ANN-Bus communications cir- power supply(requires 24 VDC) cuit.To determine the type of wire and the maximum wiring distance • Up to eight ANN-80s can be connected on the ANN-Bus that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is Controls and Indicators calculated by adding the individual worst case currents for each • AC Power module. • Alarm NOTE: For total worst case current draw on a single ANN-Bus refer to • Trouble appropriate FACP manual. DF-52417:D•3/15/2018—Page 1 of 2 WIRE REQUIREMENTS:POWER CIRCUIT Agency Listings and Approvals • 14 to 18 AWG (0.75-2.08 mm2)wire for 24 VDC power circuit is The listings and approvals below apply to the ANN-80. In some acceptable. Power wire distance limitation is set by 1.2 volt maxi- cases, certain modules may not be listed by certain approval agen- mum line drop form source to end of circuit. cies, or listing may be in process. Consult factory for latest listing • All connections are power-limited and supervised. status. • A maximum of eight ANN-80 modules may be connected to this UL: S2424 circuit. FM approved Ordering Options CSFM: 7120-0075:0211 ANN-80: Red 80 character LCD Annunciator. MEA:442-06-E ANN-80-W:White,80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Fire-Lite®Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING L I T 8 MANUFACTURING T E M S For more information,contact Fire-Lite Alarms.Phone: 800 627-3473,FAX: 877 699-4105. QUALITY SYSTEMS � ) � ) Country of Origin:USA www.firelite.com Page 2 of 2—DF-52417:D•3/15/2018 TG - 7 FS CELLULAR ALARM C O M M U N I C A T O R LTE -V FOR LTE NETWORKS T E LG UA R D P/N : TG7LVF01 COMMERCIAL FIRE PRODUCT FEATURES Certified for use on Verizon's LTE network for long, sunset-free installation. Meets UL 864 requirements for sole, primary or backup path communications. Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. Telguard Portal Telguard Cellular Service Advanced Reliability Telguard makes adopting cellular Telguard Cellular Service provides • Features the ability to utilize easy with a secure Internet portal. Verizon LTE network coverage multiple cellular technologies to The straightforward web interface for all Telguard units. Telguard's increase availability and reduce allows security dealers and central Communication Center is UL false alarms. stations to quickly and efficiently compliant and provides seamless • Automatic self-tests with central access Telguard based services 24/7. connectivity between the alarm station notification ensure the This advanced tool has multi-level panel, the Telguard family of cellular system is operating. user authorization and provides products and the central station. management of Tel uard Technical Su • Available relay output for tripping total account mana g g Support provides UL Listed Telguard cellular alarm a single point of contact for both the alarm control panel when a communicators. cellular service and Telguard product trouble condition occurs. questions. TG - 7FS CELLULAR ALARM COMMUNICATOR LTE -V FOR LTE NETWORKS TELGUARD f ») Power gl I)) • Transmit Power: ® LTE Telguard ■�■ ITlI 200mW in all bands. "°°w°" °mC,nt,r °^ Power Consumption: Al.—Pane, T.,FS �' cencraiScac°n 60mA(Standby) LTE-V 250mA(Transmission). C Land— Transformer:Transformer: 12VAC, 800mA `Optional) UL listed plug-in. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for Radio Transceiver superior in-building penetration. • LTE Bands: 4&13. • Antenna: 9" dipole with 2dBi gain Telguard products are easy to install, economical, and UL Listed. 12 ft of cable and universal mounting bracket. Accessories • FCC part 15,27 and 68 compliant. • ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. Physical Details • HGDL-O: High gain directional antenna. • EXDL-0: External antenna. • TG-7FS LTE-V: 7.5"H x 11.5"W x 3.5"D. • Shipping Weight: 8lbs. • Operating Environment: OOC to+50°C; up to 95% humidity (non-condensing). Standard Features UL Listings Commercial Fire Commercial Burglary Residential • Full data reporting. 864 • Control units& 365 Police Station 985 • Household fire accessories for fire connected burglar warning systems • Automatic self-test(60 min.&daily). alarm systems alarm units and 1023 • Household burglar • Power supply with battery harness. systems alarm systems • Locking, red metal enclosure. 1610 • Central station burglar • Two programmable supervisory alarm units; trip outputs. Line security servcies • Supports virtually all alarm formats For the most current product specifications and UL Listings visit www.Telguard.com. (Contact ID, SIA2,and others) using dial capture for universal SECURITY panel compatibility. SIGNALING ��/��� Executive Strategic • Telephone line monitor built-in, U �U4 % �I . I SECURITTYIC verimA mo with Standard Line Security. O o ASSOCIATION" NFPA' Partner NETWORK � LISTED INTERNATIONAL Gold CERTIFIED Telguard,a Division of Telular Corporation•3225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339• USA 800-229-2326,Option 5•www.Telguard.com •Copyright©2017 Telular Corporation•All Rights Reserved mzonR,,A o FIRE ALARM NOTES Johnson o Controls 1. ALL APPLICABLE CODES SHALL BE OBTAINED PRIOR TO START OF WORK JOHNSON CONTROLS 2. THE SYSTEM SHALL BE LOW VOLTAGE,PROTECTED PREMISES FIRE ALARM/CENTRAL STATION SERVICE,ALARM SIGNALS SHALL BE RECEIVED AT JCI'S CENTRAL GLOBAL CENTER OF EXCELLENCE STATION AT: 142M E EXPOSITION AVE#1A AURORA,CO 80012 14200 E.EXPOSITION AVE. AURORA, OR $0012 �� 1-en-33o-7aoa 3. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING TO THE REQUIREMENTS OF NFPA72 AND THE MANUFACTURES INSTRUCTIONS. 4. ALL CABLE SHALL BE RATEDED TH FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. [L::117ES 5. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. lei 6. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 10%.(SEE CALCULATIONS). .-------._ w The Lodge Apartments Q. E 7. ALL FIRE ALARM DEVICES ARE TO BE U.L LISTED AND COMPATIBLE. h 1-1,PI NE i - CENTER OF EX 8. ALL WIRE IS TO BE IN CONDUIT FROM DEVICE BACK BOX TO ABOVE FALSE CEILING OR TO THE BAR JOIST.WIRE MAY RUN EXPOSED HORIZONTALLY,BUT MUST BE una eeaury 0. vaimers Auey I-�-�- CELLENCE NETWORK 1'ramsr Na AV SUPPORTED PER NFPA 70 REQUIREMENTS. enlamm �" 0HealhRsml okayPaintI IDI:Insulatil9. ALL WIRE SHALL BE POWER LIMITED,FPLP UNLESS OTHERWISE NOTED. Hobby Lobby 0 O Bonefish Grill ,bre Pams .AQ -Distributorsli 10. WIRE ROUTING SHOWN IS DIAGRAMMATICAL AND DOES NOT REPRESENT ACTUAL RUNS.WIRE LAYOUT IS SUBJECT TO CHANGE AS NEEDED BY THE INSTALLING - KErvLaN: CONTRACTOR. CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS OR PANELS MAXIMUM SIGNAL LINE CIRCUIT Cmmbl-Marysville Q Amazon Fulfillment CenterPAE20 Galbi Burger Walmari SupercenleFO CAPABILITIES. ® a�r9es,saes, o. Best Buy 0 —and Dnnks 11. UNLESS OTHERWISE REQUIRED BY AHJ;ANNUNCIATOR/KEYPAD$TO BE MOUNTED AT 54"ABOVE THE FINISHED FLOOR TO THE TOP OF THE UNIT. LES SCHWAB TIRE CENTER 12. MANUAL PULL STATIONS SHALL BE INSTALLED WITH THE OPERATIONAL PORTION 42-48 INCHES ABOVE FINISHED FLOOR. ImP Dent '0 o Reillyy Auto Parts Target 0 oReilly Aum Parts 13. ALL VISUAL DEVICES SHALL HAVE THE CANDELA SET PER APPROVED PRINTS.CANDELA VALUE NOTED NEAR THE DEVICE ON DRAWINGS. - 8 LakaW, "Passing 14. CEILING MOUNTED NOTIFICATION DEVICES ARE NOTED WITH A"C". •Les Schwab Tire Cente+ 15. DESIGN IS BASED ON:CONTRACT DRAWINGS,ENGINEERED PROVIDED PLANS,SITE SURVEY.ALL EQUIPMENT IN THIS DESIGN SHALL BE INSTALLED PER ITS LISTED Coslcu wholesale 0 0 tea Gas station aem PI NE USE. Public Storage m 16607 SMOKEY POINT BLVD. pet- " 000,dt Deets 16. DEVICE LOCATIONS ARE BASED UPON APPLICABLE CODE,MANUFACTURES INSTALLATION INSTRUCTIONS,AND ACCEPTED INSTALLATION PRACTICES.SHOULD ANY suPP is sroaee CONTACT INFORMATION: av amm UNKNOWN CONDITION BE DISCOVERED DURING INSTALLATION WHICH CONFLICTS WITH APPLICABLE CODE,IT SHALL BE BROUGHT TO THE ATTENTION JCI IN WRITING PRIOR TO INSTALLATION. ARLINGTON, WA 98223. 17. THE TOTAL SOUND PRESSURE LEVEL PRODUCED BY COMBINING THE AMBIENT SOUND PRESSURE LEVEL WITH ALL AUDIBLE NOTIFICATION APPLIANCES OPERATING SHALL NOT EXCEED 110 DBA AT THE MINIMUM HEARING DISTANCE. Gissbe 18. A FIRE ALARM SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 DBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND Twin Labe 0 Marysville Toyota Caseade E LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS. Park Bi K�nk�ll Ford hj�ysvi — Forresterwoodshafts ■■RR SHEET INDEX VICINITY MAP SCALE:NTS ABBREVIATIONS IN INCHES SHEET DESCRIPTION SYMB DESCRIPTION KW KILOWATT FA000 COVERSHEET LVL LEVEL AFF ABOVE FINISHED FLOOR MAX MAXIMUM FA101 DEVICE PLACEMENT PLAN AFG ABOVE FINISHED GRADE MIN MINIMUM AMP AMPERE MNS MASS NOTIFICATION SYSTEM AUX AUXILIARY MTD MOUNTED AWG AMERICAN WIRE GAUGE N4 NEMA4-NON CORROSION-PROOF ENCLOSURE BFG BELOW FINISH GRADE N4X NEMA4-CORROSION-PROOF 3 e BLDG BUILDING ENCLOSURE N12 NEMA 12-SEALED ENCLOSURE g� C CEILING MOUNTED NAC NOTIFICATION APPLIANCE CIRCUIT s CIRC CIRCUIT # NUMBER 5= PNL PANEL COND CONDUIT PH PHASE i SCOPE OF WORK e= ON DOWN PS POWER SUPPLY z DWG DRAWING CITY QUANITITY THE NEW SYSEW FIRE TEM SHALLM. INCLUDE: SEC SECONDARY 8`- DEGREE SLC SIGNAL LINE CIRCUIT • AN ADDRESSABLE FIRE ALARM CONTROL UNIT. j-E �A ELEC ELECTRICAL TEMP TEMPERATURE • AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. EXT EXTERIOR • A DOCUMENT BOX IS TO BE INSTALLED BY THE CONTROL UNIT. 6 TYP TYPICAL • A FIRE ALARM ANNUNCIATOR 15 TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. .� EX EXISTING DEVICE V VOLTAGE • A SMOKE DETECTOR IS TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT E. EQUIP EQUIPMENT VAC VOLTAGE ALTERNATING CURRENT THE ELECTRICAL ROOM. % • MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN T OF EGRESS DOORS. L= XP EXPLOSION PROOF W WATTS • WALL-MOUNTED HORN/STROBES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. FA FIRE ALARM VIP WEATHERPROOF • WALL-MOUNTED STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. WG WIRE GUARD • A WEATHER-PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE SPRINKLER ROOM. FL FLOOR • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. 2 c FT FEET WE) WIRELESS DEVICE • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. W/ WITH • 120VAC SURGE SUPPRESSORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. a5 GND GROUND • MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS. THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES. et E= THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM Ft EXISTING DUCT DETECTORS. 3' THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN t e ALARM CELLULAR COMMUNICATOR. €E THE BUILDING IS FULLY SPRINKLERED. 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-P510 OWN so g$ 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R Y 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN P2 z" 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN e= ISSUE LOG: 2 SOP SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D ya 7 OF FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG �g e� $ AIM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D EF s 2 AIM D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D - - r' CODE ANALYSIS x 4 BUILDING OCCUPANCY TYPE M,B,S-1 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D ax NUMBER OF STORIES TWO(2) ;.g PROJECT AREA 16 404 SQ.Fr. 8 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 2.5"D C TYPE OF SYSTEM ADDRESSABLE INITIATION Fit CONVENTIONAL NOTIFICATION € LISTING AGENCIES(UL,FM,MEA,ULC) UL 864 9 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D WIRING TYPES OPEN CEILING,CONDUIT X TYPE OF COMMUNICATION REMOTE STATION 10 HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED LES SCHWAB €� AUDIBLE NOTIFICATION TEMPORAL3 WP e VISUAL NOTIFICATION PUBLIC MODE BUILDING SPRINKLER SYSTEM FULLY SPRINKLERED 1 55 SURGE SUPPRESSOR DITEK DTK-120HW OWN F E STANDARDS NFPA 72(2019),NFPA 70(2017) LES SCHWAB TIRE CENTER s APPLICABLE CODES IBC(2018),IFC(2018),IMC(2018)ASME/ANSI A717.1(2017) 2 SMOKE DETECTOR-DUCT EXISTING V 05 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING 16607 SMOKEY POINT BLVD. 1 KB KNOX BOX EXISTING ARLINGTON,WA 98223. �q QR} DESIGNED BY: P.ROJAS frt DRAWING ACCEPTANCE 2 f V y FLOW DETECTOR/SWITCH EXISTING DRAWN BY: P.ROJAS CHECKED BY: M/25/2025 S� THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JOHNSON CONTROLS EQUIPMENT AND IS NOT TO 1 HP HIGH AIR PRESSURE SWITCH EXISTING JOB/CASE#: 1-91ZJW I BE USED FOR ANY OTHER PURPOSES.IT IS THE RESPONSIBILITY OF THE LOCAL JOHNSON CONTROLS SALES B SERVICE OFFICE(SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. RECORD DRAWINGS CONS 1 LP LOW AIR PRESSURE SWITCH EXISTING OT FOR TRUCTION ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JOHNSON A CONTROLS OFFICE AT THE ADDRESS LISTED ABOVE. a g 11 >< VALVE-GENERAL EXISTING MONITORING LOCATIONS SHEET: aR ` JOHNsoN coNrnoLB ALARM SERVICE CO:544525 e 14zoo EXPOSITION AVE. UL LISTING:5994-183 1 f� SIAMESE FIRE DEPARTMENT CONNECTION EXISTING ._ AURORA,CO.10012 1-800-428-7124 COVER SHEET �e � DEVICE LEGEND 0o L s$ o FA000 �a I I •I 1 •1 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:4/25/2025 6:24:23 p.m. LAST SAVED BY:JROJASPH FILE PATH:C:\Users\jrojasph\DownLoads\LSTC_Arlington_WA_FA_DD01_Estimate.dwg o ir o zo Johnson c 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-2DOX OWN controls 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN JOHNSON CONTROLS GLOBAL CENTER OF EXCELLENCE 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R 142M E EXPOSITION AVE#1A AURORA,CO 80012 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN 1-877-330-7404 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN 2 OS p SMOKE DETECTOR.PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D 7 F� FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG CENTER OF ExCEUENCE NETWORK 8 NM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D 2 aM D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D KEvPIAN: FIRED 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D II >< P UMPI 8 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQx 2.5"D u MM10 "' I 9 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D AM V 1 Wp� HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2R1 INCLUDED / m®�— 9 AN NM A� 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN CONTACT INFORMATION: / ©W-1- ISPRINKLER 2 I SMOKE DETECTOR-DUCT EXISTING FACU FAC NAC DOC SS F / o F 2 ®RTSREMOTE ALARM INDICATING AND TEST SWITCH EXISTING 1 AIM 2 AIM 4 95 CID P31 KB KNOX60X EXISTING ROOM QR} 2 f V y FLOW DETECTOR/SWITCH EXISTING ELEC.ROOM �/ CEILING OVER OP 1 HP HIGH AIR PRESSURE SWITCH EXISTING SHOWROOM IS 95 CD 75 CD BELOW ° AUGMENT BAYS 1 LP LOW AIR PRESSURE SWITCH EXISTING PARTS OFFICE 11 VALVE-GENERAL EXISTING SHOWROOM Q p STORAGE RM. 1 . 1 . SIAMESE FIRE DEPARTMENT CONNECTION EXISTING AUGMENT FIT OFF CE Y 3 E STAIRS STAIRS e� 8> E>�3� s= GENERAL NOTE PARTS ROOM HALL 11 ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. e= REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT z LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP g`- CALCULATIONS. 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD 'E F VERIFIED. 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 $9 (NATIONAL ELECTRIC CODE). Eh 95 CD 5)WHERE CONDUIT 15 REQUIRED,MINIMUM SIZE SHALL BE 3/4". _ 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE €m rC RTU ki 95 CD PATH. F 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE AN5 ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. II 11 p RT RTS CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO WAREHOUSE - 135 CD DIAGONAL RUNS ARE PERMITTED. 2€ HALL 135 CD WAREHOUSE UNLOADING 30 CD% BI THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. g` SALES AREA f —— RTU#2 Y§ I aN 5 I go L11 D RT RTS _------- 3' N _ LocKERRM. FLAG NOTES J. 5 5 CD ® NEW FIRE ALARM CONTROL UNIT SHALL BE CONNECTED TO DEDICATED 1 120 VAC POWER.LABEL CKT BREAKER"FIRE ALARM". ��'t3 WOMEN '$ \15 F 2 FIRE ALARM CONTROL UNIT SHALL COMMUNICATE TO MONITORING ® STATION VIA SOLE PATH CELLULAR COMMUNICATION. .g 8 SERVICE ROOM S PEIRVVIISIONDULE FOR FIRE ALARM CELL DIALER COMMUNICATOR TROUBLE aT 15 RESTRM. 15 MEN 10 Hp MONITOR MODULE FOR NAC POWER SUPPLY TROUBLE SUPERVISION. x e 30 CD AIM LP DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF WATERFLOW ISSUE LOG: SWITCH. INSTALL EXTERIOR HORN STROBE NEXT TO THE SPRINKLER ROOM. 95 CD ya ®i 10 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVES. F g ®8 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVE. e 75 CD MONITOR MODULE INSTALLED FOR SUPERVISION OF FIRE PUMP. SALES AREA 9 SERVICE BAYS 10 PRESSURE SWITCH DUAL MONITOR OAT THE DRY DULE LSYSTEM RISER.LED FOR RVISION OF HI/LOW AIR E� 2 N D LEVEL CLOUNGER 11 FMONITORIELD VERIFY DILLE ONSUPERVISION OF EXISTING DUCT DETECTORS. g4 „k e5 gg .0 FROM FACU 5 AD 75 CD F FAA x KB WIRE CHART COL SCHWAB SYMBOL CIRCUIT DESCRIPTION MAIN LEVEL SLC CIRCUIT MINIMUM SIZE< TYPE AND TYPE OF WIRE F A SIGNALING LINE CIRCUIT 2 (POWER LIMITED) -#18AWG LES SCHWAB TIRE CENTER s ANNUNCIATOR DATA BUS AD ANN (BLK/RD=DATA) 4418AWG (WHT/GRN=PWR) E R NOTIFICATION APPLIANCE TRIP CKT. =g C TRIP (COMBINED HORN B VISUAL CIRCUIT) 2-#14AWG aF 88 INITIATING DEVICE CIRCUIT 16607 SMOKEY POINT BLVD. D IDC (NON-INTELLIGENT DEVICES) 2-#18AWG ARLINGTON,WA 98223, g§ P POWER 24V NON-RESETTABLE POWER 2414AWG DESIGNED BY: P.ROJAS RT TEST REMOTE TEST STATION TEST 441— DRAWN BY P.ROJAS 5 CHECKED BY: 04/25/2025 Z ZONE 2-.ZONE CIRCU (NON-INTELLIGENT DEVICES) IT 2- JOB/CASE#: 1-91ZJWV1 SH=SHIELDED 'WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED NOT FOR �$ CONSTRUCTION A� C SHEET: e,R 5£ DEVICE PLACEMENT PLAN �e H�1 DEVICE PLACEMENT PLAN o� N U 5CALE 1�8=1 8' N FEE 1 0 6 FA O Wo s$ o �a • •I•.•I• •1 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/21/2025 6:24:27 p.m. LAST SAVED BY:JROJASPH FILE PATH:1:\Users\jrojasph\Downloads\LSTC_Artington_WA_FA_DD01_Estimate.dwg 5t FIRE ALARM NOTES Johnson Controls 1. ALL APPLICABLE CODES SHALL BE OBTAINED PRIOR TO START OF WORK 2, THE SYSTEM SHALL BE LOW VOLTAGE,PROTECTED PREMISES FIRE ALARM/CENTRAL STATION SERVICE,ALARM SIGNALS SHALL BE RECEIVED AT JCI'S CENTRAL JOHNSON CONTROLS S STATION AT: GLOBAL CENTER OF EXCELLENCE 142M E EXPOSITION AVE YtA 14200 E.EXPOSITION AVE. " AURORA,co 80012 k,''" AURORA,COLORADO 80012 ' J-877-330-7404 3. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING TO THE REQUIREMENTS OF NFPA72 AND THE MANUFACTURES INSTRUCTIONS. 4. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 5. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. 6. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 10%.(SEE CALCULATIONS). 3` 7. ALL FIRE ALARM DEVICES ARE TO BE U.L LISTED AND COMPATIBLE. - 8. ALL WIRE IS TO BE IN CONDUIT FROM DEVICE BACK BOX TO ABOVE FALSE CEILING OR TO THE BAR JOIST.WIRE MAY RUN EXPOSED HORIZONTALLY,BUT MUST BE _•; - I. :. ` .. EXCELLENCE NENJORK SUPPORTED PER NFPA 70 REQUIREMENTS. - 3 ana onal -a i .m,vskav I' . € le.9uiatr 9. ALL WIRE SHALL BE POWER LIMITED,FPLP UNLESS OTHERWISE NOTED. 10. WIRE ROUTING SHOWN 15 DIAGRAMMATICAL AND DOES NOT REPRESENT ACTUAL RUNS.WIRE LAYOUT IS SUBJECT TO CHANGE AS NEEDED BY THE INSTALLING CONTRACTOR. CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS OR PANELS MAXIMUM SIGNAL LINE CIRCUIT ." KEYRnN. CAPABILITIES. 11. UNLESS OTHERWISE REQUIRED BY AHJ;ANNUNCIATOR/KEYPADS TO BE MOUNTED AT 54"ABOVE THE FINISHED FLOOR TO THE TOP OF THE UNIT, LES SCHWAB TIRE CENTER 12. MANUAL PULL STATIONS SHALL BE INSTALLED WITH THE OPERATIONAL PORTION 42-48 INCHES ABOVE FINISHED FLOOR. F __ 13. ALL VISUAL DEVICES SHALL HAVE THE CANDELA SET PER APPROVED PRINTS.CANDELA VALUE NOTED NEAR THE DEVICE ON DRAWINGS. 14. CEILING MOUNTED NOTIFICATION DEVICES ARE NOTED WITH A"C". # - v Les Bohrr L 15. DESIGN IS BASED ON:CONTRACT DRAWINGS,ENGINEERED PROVIDED PLANS,SITE SURVEY.ALL EQUIPMENT IN THIS DESIGN SHALL BE INSTALLED PER ITS LISTED ?OD;iiml DIBs ,StrJDen NPrAB- '*, USE. 16607 SMOKEY POINT BLVD.16. DEVICE LOCATIONS ARE BASED UPON APPLICABLE CODE,MANUFACTURES INSTALLATION INSTRUCTIONS,AND ACCEPTED INSTALLATION PRACTICES.SHOULD ANY - 1 e -1s r1e=s; �.L _ CONTACT INFORMATION: UNKNOWN CONDITION BE DISCOVERED DURING INSTALLATION WHICH CONFLICTS WITH APPLICABLE CODE,IT SHALL BE BROUGHT TO THE ATTENTION JCI IN w •.... WRITING PRIOR TO INSTALLATION. ARLINGTON, WA 98223. 17. THE TOTAL SOUND PRESSURE LEVEL PRODUCED BY COMBINING THE AMBIENT SOUND PRESSURE LEVEL WITH ALL AUDIBLE NOTIFICATION APPLIANCES OPERATING - v, SHALL NOT EXCEED 110 DBA AT THE MINIMUM HEARING DISTANCE. - ,s`MeryS mkT6yeta 18, A FIRE ALARM SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 DBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS. - `i,A .. Farar41S8i II FOTd SHEET INDEX gsaE Waoda e c " SHEET DESCRIPTION 1;1 VICINITY MAP I SCALE:NT S ABBREVIATIONS IN INCHES FA000 COVER SHEET SYMB DESCRIPTION KW KILOWATT FA101 DEVICE PLACEMENT PLAN LVL LEVEL FA201 RISER DIAGRAM&CALCULATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUM AEG ABOVE FINISHED GRADE MIN MINIMUM FA301 PRODUCT TYPICALS �--4 AMP AMPERE MNS MASS NOTIFICATION SYSTEM GIBBENS DRAKE SCOTT,INC sane.es,�-aeaa,sores lao BA owN,>nlsso:sal wm AUX AUXILIARY MTD MOUNTED AWG AMERICAN WIRE GAUGE N4 NEMA4-NON CORROSION-PROOF y ENCLOSURE 8 BEG BELOW FINISH GRADE NEMA4-CORROSION-PROOF g. N4X ENCLOSURE t BLDG BUILDING N12 NEMA 12 SEALED ENCLOSURE C CEILING MOUNTED NAC NOTIFICATION APPLIANCE CIRCUIT CIRC CIRCUIT # NUMBER SCOPE OF WORK sg PNL PANEL NEW FIRE ALARM SYSTEM. .a '�53isy C PH PHASE CONO CONDUIT THE NEW SYSTEM SHALL INCLUDE: 'PO kFT'I%1EpS G. k ON DOWN PS POWER SUPPLY • AN ADDRESSABLE FIRE ALARM CONTROL UNIT. ak DWG DRAWING QTY QUANITITY AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. SEC SECONDARY • A DOCUMENT 60%IS TO BE INSTALLED BY THE CONTROL UNIT. DEGREE SLC SIGNAL LINE CIRCUIT A FIRE ALARM ANNUNCIATOR IS TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. if° • A SMOKE DETECTOR IS TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT ELEC ELECTRICAL TEMP TEMPERATURE� THE ELECTRICAL ROOM.� EXT EXTERIOR MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN 5 OF EGRESS DOORS. TYP TYPICAL • HORN/ST0.0BES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. �$ EX EXISTING DEVICE V VOLTAGE STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. t? A WEATHER-PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE SPRINKLER ROOM. EQUIP EQUIPMENT VAC VOLTAGE ALTERNATING CURRENT • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. S XP EXPLOSION PROOF W WATTS • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. FIRE ALARM SYMBOLS L' I WP I WEATHERPROOF • 120VAC SURGE SLJPPRE55ORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. FA FIRE ALARM • MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS. FL FLOOR LNG WIRE GUARD QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX -�� WE WIRELESS DEVICE FT FEET THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES. 8 GND GROUND WI WITH 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM B EXISTING DUCT DETECTORS. THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ALARM CELLULAR COMMUNICATOR. g THE BUILDING IS FULLY SPRINKLERED. 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R s� BEFORE INSTALLATION OF ANY SYSTEM COMPONENT,THE INSTALLATION TECHNICIANS SHALL CONFER AND COORDINATE WITH THE GENERAL CONTRACTOR AND ALL OTHER APPLICABLE TRADES TO ENSURE THE INSTALLATION LOCATION WILL NOT CONFLICT WITH OTHER TRADES. 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN gb ALL WIRE SHALL BE OPEN-RAN OR CONCEALED IN THE WALLS OR CEILINGS.WHERE THE WIRE IS BELOW 10',IT SHALL BE INSTALLED IN W'EMT CONDUIT. R"g 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN § UPON AHJ'S ACCEPTANCE OF THE NEW SYSTEM,THE EXISTING SYSTEM SHALL BE REMOVED. 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQ x 2.5"D s" 7 ❑F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG E� ISSUE LOG: �� MUM DATE INT OESCRIMION 4 - B ADA ADDRESSABLE INPUT MODULE FIRELITE MMF-300 V SQ x 2.5"U DPo�ansrzs PRo aaroosm uvour ;i soos 7issas xAD sIwF PPAwImc i� FIRE ALARM MATRDI I SEQUENCE OF OPERATION 2 aI D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 V SQ x 2.5"D SYSTEM OUTPUTS e, 1 ®to ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300.10 4"SQx 2.5"D F z O 5 ~ a O 2 ® ADDRESSABLE OUTPUT MODULE FIRELITE CRF-300 4"SQ x 2.5"D sa a Ei O CODE ANALYSIS O z 0 BUILDING OCCUPANCY TYPE M,B,S-1 o m ? 0 8 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 2.5"D p NUMBER OF STORIES TWO(2) o 1. z z z qq O $ PROJECT AREA 16 404 SQ.FT. 8 p ' 0 0 1= 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQ x 2.5"D w c$ TYPE OF SYSTEM ADDRESSABLE INITIATION B CONVENTIONAL NOTIFICATION m a 4a z m z C LISTING AGENCIES(UL,FM,MEA,ULC) UL 964 J as o w Y m 0'. w 0 F X j u 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D WIRING TYPES OPEN CEILING,CONDUIT I�'F ; S 4 ✓i O ,o a z z v, a z '= u � zw w TYPE OF COMMUNICATION REMOTE STATION w O a p g O I- F O t§ ¢ Z5z r- i N i E z a z o y a m g 1 HORN/STROBE•WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED Y AUDIBLE NOTIFICATION TEMPORAL3 9 z dq z q¢ a ¢� w 0 w a z WP g n VISUAL NOTIFICATION PUBLIC MODE o N E m O O O m 0 m o I N a g 0 Z o g= a z m r a I= rc z E w z > rc z a rc z 2 0 rc z 1 SS SURGE SUPPRESSOR DITEK DTK•120HW OWN BUILDING SPRINKLER SYSTEM FULLY SPRINKLERED D g ❑ I_ w z 0 z O 0 0. 0 0 zo 0 0 0 � o_ )8 F H O F V , 4J a 2 0 u I STANDARDS- NFPA 72(2019),NFPA 70(2017) ? O F S Z5 ti u F 5 LC F u F N ¢ r t LES SCHWAB TIRE CENTER D' I' Z W a 2 2 N 2 Z UJ 6 2 y M Z UJ Z O Z o Z B, 0 M M a . w > o > o a a w 2 S SMOKE DETECTOR-DUCT EXISTING APPLICABLE CODES IBC(2018),IFC(2018),IMC(2018)ASME/ANSI A117.1(2017) 0 s O , m z C7 O o z G O Z ¢ z o w O E- < z ;j z z z & z z z w 'ni` w w a w z z -' z > a arc a s rq a ft ti < Er F Z LL > gs < m o w F o w s w g z a F m 0 a o a 00 a 4 C, a o < 0 � a > j 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING D' �J O W N O G w O C J w O U d' O w O w U �' 0 O 0 0 16607 SMOKEY POINT BLVD. $ SYSTEM INPUTS c0 o z m > cT a a m 1- a m F a m t- a m 1- If a '� a 2 ¢ a CONTROL UNIT FUNCTIONS 1 KB KNOX BOX EXISTING ARLINGTON,WA 98223. g� SYSTEM RESET(ONE S_YS_TEM_S_NORM4L" X _ 2 �; �_ SYSTEM SILENCE X X� .._......_,..,......__»._.._..-... ._ .». ._._ ._.. - --. � FLOW DETECTOR/SWITCH EXISTING ONE POINT FOR RESET) _ X X � � DESIGNED BY: P.ROJAS DRAWN BY. P.ROJAS s DRAWING ACCEPTANCE ALARM DEVICES THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JOHNSON CONTROLSE EQUIPMENT AND IS NOT TO ___ WATERFLOW SWITCHES _ _ X _ _X X %_ X __ o MANUAL PULL STATIONS % ,__ _ X X x_ _X __ 1 HP HIGH AIR PRESSURE SWITCH EXISTING JOB r EASE x: 1-9lzlwvl BE USED FOR ANY OTHER PURPOSES.IT IS THE RESPONSIBILITY OF THE LOCAL JOHN50N CONTROLS SALES&SERVICE OFFICE(550) - _._....__.. .._. .,-.._..._..._.._........._._......_. .- ._.. _- _-. ... ......_- _...... ..... ..... TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO SMOKE DETECTORS % X X % X = RELEASING THEM TO THE FIELD. SUPERVISORY DEVICES Ep SPRINKLER TAMPER SWITCHES x x x 1 LP LOW AIR PRESSURE SWITCH EXISTING g RECORD DRAWINGS `""JIRPRESSURESV4TCHEs` ._.-�. z_. ❑ SHOP DRAWINGS "o ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JOHNSON I(NOX BOX TAMPER SWITCH _ � % X X & CONTROLS OFFICE AT THE ADDRESS LISTED ABOVE. -DUCT SMOKE DETECTORS % % X % .S a 1 VALVE-GENERAL EXISTING s R MONITORING LOCATIONS TROUBLE FUNCTIONS SHEET. P1 OSS OF DIALTONE OR CELL DIALER C0 ECT X X X ».. JOHNSON CONTROLS ALARM SERVICE CO:144525 _ sy 14200 EXPOSITION AVE. uL USnNG:599aa e3 _FIRE ALARnn sysrEMAC PowER FAILIP _,. _ _.__ __ x_ X _- 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING # AURORA,CO.80012 FIRE ALARM SYSTEM LOW BATTE X_ % _ _ % �- --+ COVER SHEET _ _-_ 7-800.428.7124 - ABNORMAL CIRCUIT OR X % X YX sg 3 ORDER OF OPERATION /1 DEVICE LEGEND n FA000 1 •I•• 1 ••1• 1 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:07 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_Arlington_WA_FA-DD01_1-91 ZJWVI.dwg 60 FIRE ALARM SYMBOLS ,OI1nSOn CITY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX Controls 1 FAN FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN ee N CONTROLS GLOBAL 6 GLOBAL CENTER OF EXCELLENCE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN 142M E EXPOSITION AVE#1A AURORA,CO W12 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SBBOKIT-R 1-877-330-7404 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN 1 DOL FIRE ALARM DOCUMENT BOX SPACE AGE SSUG0672 OWN is 2 QP SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.51) CENTER OF E%CELLENCE NETWORK 7 �F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG 8 Ana ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D NEYPLAN: ><MM223 RED FI 2 AIrAD DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx2.5"D /I M21 PUMP UM IAA 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4'SQx 251) �M20 1 / 7MM 10PMiB i ^ 2 0® ADDRESSABLE OUTPUT MODULE FIRELITE CRF-300 4"SQx 2.5"D M17 o I� ¢ >1 MI6 M;1 IM~ * a R STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 251) M15 5 M14�r ♦ t 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"IQ x 2.5"D EO � L M A 9 73 M' 8 c CONTACT INFORMATION: _ 1 M_ 6 — — _...- / 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SO x 2.5"D / 110 — Pr_ / _ i HORN/STROBE-WALLMOUNT-WEATHERPROOF SYSTEM SENSOR P1RK INCLUDED FACU FAC NAC DOC IS AA F 24 A FAA / F A � WP 1 AI AIM Tj�� n C70 C70 �_ C70 95 CD I 1 55 SURGE SUPPRESSOR DITEK DTK-120HW OWN D 3 2 -✓ 'o ¢ > SPRINKLER ROOM SMOKE DETECTOR-DUCT EXISTING MECH.RM. TO FACU > a C TO FACU ROOM S D02 TO FACU - ¢ 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING CEILING OVER SHOWROOM IS _ _.� 75 CD 1 KB KNOX BOX EXISTING BELOW _ ALIGMENT BAYS a PARTS A A ¢ 2 r R, ROW DETECTOR/SWITCH EXISTING -----"_— -_'�_-- OFFICE "�V/" STORAGE RM. o SHOWROOM 1 HP HIGH AIR PRESSURE SWITCH EXISTING �GffiHHNB DRAKE SCOT'F,INC ALIGMENT FIT vMzo�.cazm",mis�i�sdlii� ��1yyy MGR'S 1 LP LOW AIR PRESSURE SWITCH EXISTING ¢ OFFICE - ¢ 11 >I VALVE-GENERAL EXISTING 30 CD C10 1 F�y SIAMESE FIRE DEPARTMENT CONNECTION IXISTING r EOL P HALL a5 TO FACU ! - PARTS ROOM GENERAL NOTE p a 1)ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROMTHE FACU TO OPERATE. TLo-N FROM 2N a REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT F M03 LEVEL - LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS. g 95 CD a 1 55 CD ¢ 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD =f VERIFIED. —L C 4)ALL FRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 RTU#1 _ — M04 — a M30 F (NATIONAL ELECTRIC CODE). 11 MA5 D—$——RT RTS TO FACU -�-C7- 55)WHERE CONDUFF IS REQUIRED,MINIMUM SIZE SHALL BE 3/4". $ 1 )ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE PATH. WAREHOUSE 150 CD 3 135 CD 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE C7—C7—C7 C7 C7 C7 C7 C7 C7 ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. q` —a —¢ ���CCC CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO RTU#2 WAREHOUSE UNLOADING DIAGONAL RUNS ARE PERMITTED. eSALES AREA t7 4 MOB S ¢ 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. 1 —_RT u �AJ a - �91 CD �LOCKER RM. FLAG NOTES u SERVICE ROOM ¢ NEW FIRE ALARM CONTROL UNIT SHALL BE CONNECTED TO DEDICATED eX' WOMEN 120 VAC POWER,LABEL CKT BREAKER"FIRE ALARM". 5y F 2 FIRE ALARM CONTROL UNIT SHALL COMMUNICATE TO MONITORING 8 I O STATION VIA SOLE PATH CELLULAR COMMUNICATION. TO FACU O MONITOR MODULE FOR FIRE ALARM CELL DIALER COMMUNICATOR TROUBLE �g 15 SUPERVISION. k RESTItM. t5 MEN a HP MONITOR MODULE FOR NAC POWER SUPPLY TROUBLE SUPERVISION. B a 0 CD 1 LP M27 DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF WATERFLOW ISSUE LOG: .� 0SWITCH. INSTALL EXTERIOR HORN STROBE NEXT TO THE SPRINKLER ROOM, 000+a ms PR m—I.ur pp f a EOL F C9—C9—C9—C9—C9 C9 C9 C9 O7 som n Ao zl+oP ow+ww, 5R 10 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVES. $ 115 CD M2 F 5 I ¢ C 0MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVE. _� EOL m 75 CD O MONITOR MODULE INSTALLED FOR SUPERVISION OF FIRE PUMP. SALES AREA >:E a DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF HI/LOW AIR Y 2 N D LEVEL CUSTOMER SERVICE BAYS a 1 PRESSURE SWITCH AT THE DRY SYSTEM RISER. ag O MONITOR MODULE FOR SUPERVISION OF EXISTING DUCT DETECTORS. � LOUNGE 11 FIELD VERIFY LOCATION. ¢ QADDRESSABLE RELAY MODULE FOR HVAC SHUTDOWN,FIELD VERIFY LOCATION. og I a A-AA AA �AAAAA-A-A-A-A-A-A� FROM 9 - FACU €,x AD M25 F FAA C9-C9-C9-C9 C9 C9 EOL WIRE CHART CIIRRCPET ANDI ITYPE OFI IWIRE -�'�.••�.____ MAIN LEVEL SYMBOL CIRCUIT DESCRIPTION 's€ A slc 2-#IBAWG LES SCHWAB TIRE CENTER SIGNALING LINE CIRCUIT (POWER LIMITED) AD ANN (BLKANN/II RD-DA A)ATOR BUS 4-#1BAWG (WHT/GRN=PWR) 25 C TRIP NOTIFICATION APPLIANCE TRIP CRT. 2-#14AWG D IDC (COMBINED HORN @ VISUAL CIRCUIT) 2#IaAWG INITIATING DEVICE CIRCUIT /6607 SMOKE Y POINT BLVD. g P (NON-INTELLIGENT DEVICES) ARLINGTON,WA 98223. t"$ P POWER 24V NON-RESE TABLE POWER 2414AWG DESIGNED BY: P.ROJAS RT TEST REMOTE TEST STATION TEST 4-418AWG DRAWN BY: P.ROJAS 8 CHECKED BY: 04/25/2025 Ell IN=SHIELDED *WIRE MUST BE SHIELDED AS INDICATED TW-TWISTED �F JOB/CASE> 1-91ZJWV1 gb i� SHEET'. 5e `o$ A DEVICE PLACEMENT PLAN DEVICE PLACEMENT PLAN a� N U/� ° 4 B' FA101 I•,..•I•..I..•1 30'X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:10 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_ArtingtDILWA_FA-DD01 1-91ZJWV1.dwg FRCP BATTERY CALCULATIONS j Total Total Qry Part# Dsacnpdon Standby Ajar. Standby Ajar. CIRCUIT LOAD$VOLTAGE DROP CALCULATIONS Jo nson I' 1 ES-200X Fire Al Pa 0.14100 0.25700 0.1410 0.2$ Source: NAG#1 Controls 1 PWRM0024 OpliO 124 13Am T f (inside. panel) 0.00700 0.00800 O.W70 0. Circuit Number: 1 IPOTS-COM POTS i(tPIde the panel) 0.04000 0.0410G 0.0400 (i Device Description Standby Alarm C5 C6 C7 CS C9 C70 1 ANN-80 Remote Annunciefor 0.01500 0.04000 0.01W 0. JOHNSON CONTROLS 2 S0365 Phslcelecblc Smoke D-tor MOOOSD OAo450 10004 0,009C SRLED WALL MOUNT STROBE RED(15 od) 0.00000 0.01800 0 0 1 0,018 2 0.036 0 0 0 D 0 0 GLOBAL CENTER OF EXCELLENCE u 7 BG-12LX Menu lP llSmeon D.00IAB G.005G0 0.0028 0. SRLED WALL MOUNT STROBE RED(30 cd) _- _ _ _ 000000 002200 0 0 0_ -O 1 0,022 1 0.022 1 0.022 0 0 14200 E EXPOSITION AVE#1A __ __._______________________ .__...__._._.__. ..._..___ _____..-_._ _____.__. _ ___ _ _____... .._...___ ___.__.... FIRE ALARM SYMBOLS 8 MMF.300 Writor Module with LED(Full Sire) - O.WIX?6 05MO-0 Ota 0. BREED________ WALL MOUNT STROBE RED(75 Ed) 000000 007000 0 0 0 0 O 0 1 0.07 1 0.07 0 0 AURORA,CO 80012 '.. _ _____- ________. _____.___------------------- _...___ _......._ __.. ._. _.._..._.__----------0 0 0 0 0 D 0 0 0 0 QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX 1-877-330-740a 1 M.F-30D-10 Ten-hpa Not NDodue ___ 0.00035 0.00550 1,1111 PCZRLED CEILING MOUNT STROBE RED 0.00000 0.12aD0 0 0 0 0 O 0 0 0 0 0 2 0.24 SPARE 1 FL-PS10 .. NAC 13oosto,Power supply(Trggor Cuneaj u.oODm 0.00200 0.0000 ¢ PC2RLED CELING MOUNT HORN STROBE RED(150 ed) 0.00000 0.18900 0 0 0 0 1 0.189 0 0 0 0 0 0 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN P2RLE0 WALL MOUNT HORN STROBE RED(75 cd) 000000 0.087tp 0 0 0 0 0 0 1 0087 0 -- 1 0.087SMntltry Current Thal Hoes= 02529 %24 = 6. P2RLE0 WALL MOUNT HORN STROBE RED(95 d) OOOWO 009200 0 0 2 0184 0 0 0 0 1 0.092 O 0 (H.Pre P2RLEO WALLMOUNT HORN STROBE RED(135 cd) 000000 _ 018900 0 0 0__ 0 1 0189 0 0 0 0 0 0 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWNis Alum Current Total Mnua,= 0.5603 X 083 0.0 P2R WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 1 0212 0 0 0 0 0 0 0 0 0 0 (S Mna) #Devices 1 D.212 3 0.202 5 0.436 3 0.179 3 0.184 3 0.327 -C- 0 Total = 6.11 Circu@Amps 0.212 0.202 0.436 0.179 20.184 0.327 O.ODD 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R XELLENCE NETWORK 2O%BaBerySafetywrgin 1.zzsi Circuit Length HO 100 100 250 100 l) ISO 0 Tote:Vokage Drop(14ai 0.14 0.1] 0.70 a 5 0.38 0.00 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN Total AN Rated Batteries Needed • T.3 Total EOL Voka a 14 a 20.26 20.27 19.70 20.29 06 20.02 20.40 Total AM Rated Batteries Supplied r 12 NOTE: VOLTAGE FORMULA USED IS: 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN KEYPLAN: NAC#1 BATTERY CALCULATIONS VD=LENGTH CIRCUIT MEASURED ONE-WAY IN FT. X LOAD IN AMPERES X RESISTANCE 00316 FOR 14AWG X 2 FOR RETURN RESISTANCE)Qry Part# Description Standby Am'.warm Stdby an Alarm 2 SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D 4 SRLED WALL MOl2JTSTROBE RED(15cd) _ 0.00000 0.01800 TeGOCOD T oa ( ) ( ) ( ) (WIRE RESISTANCE VALUES REFERENCED FROM NEC TABLE 8 2 SRLED WALL MOUNT STROBE RED(304 0.00000 0.02200 00000 0,0440 2 BRLED WALLMOLNTSTROBERED(75cd) GOOOCO (107000 0.0000 0.1400 7 ❑F FIRE ALARM PULLSTATION FIRELITE BG-12LX IGANG 1 FURLED RED 0.00000 Q08700 OOWO_ DD87_ TG-7FS-V BATTERY CALCULATIONS____ 2 PC2RLED _CEILING MOUNT HORN STROBE RED (115 d) 0.00000 ¢1Xp0 00000 0.29 Total Tatel 1 PC2RLED CEILING MOUNT HORN STROBE RED(150 d) I 0.mo0G o.1rmGG o.0000 0.�- 8 alN ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx2.5"D 1 P2RLED WALL MOUNT HORNSTROSE RED(75 d) GOODDO 0.05700 0.0000 0.08 City Part Description Standby Alum Standby Alarm 3 P2RLED WALL NO,HORN STRODE RED Diii 0BOOM 0OWOO 00000 02760 1 TG7FS-V Cell Dialer Communicator 0.08300 0.23000 0.083<T 0.2300 1 P2RLE0 WALL MOINYT FERN STROBE RED(135 cdJ 0.00000 0.1e9oo 0.00Do D.1 0.0630 023DO 2 ant DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D 1 p2i._ _____ .._ _._ _ ._..__._ _._ _ _ _ 1 P2R WPi1 MJUNR HORNSTROBE RED(110 cd) O.000W 0.2120D 0.0000 0.21 ___ .....___._ _._._..._... .._._._-__. _..___._..--------------I _________ ___._...... _.._.._-.._._.. D O.OWO 5 Standby Current Total Hours= 0.0830 X 24 = 1.9920 CONTACT INFORMATION: Standby Cu II:Taal Hours• O.0000 X24 = D.GD (Hours) 1 AIM 10 ADDRESSABLE INPUT MODULE-10INPUTS FIRELITE MMF-300.10 4"SQx 2.5"D (Fours) Alan Current Total Minutes= 0.2300 X.DB3 - 0.0191 Alarm Current Taal Mputes= 1.5380 X.083 D.1275 (5 Mine) (5 Mns) Total = 2.0111 2 ®0 ADDRESSABLE OUTPUT MODULE FIRELITE CRT300 4"SQx 2.5"p Total 0,127 '.. 20%Bedery savory Margin - = 0.02 20%Battery Safety Margin = CAM 8 � STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED TSQx 2.5"D Total AN Rated Batteries Needed = D.ISW Total AH Rated Batteries Needed m 2A133 Total AI Rated ast ariee Su Ilea 7 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQx 2.5"D Total AH Rated Batteries supplied 7 C 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D A CALCULATIONS I WP1§ HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN G�ffiHENS DRAKE BCOTT,INC a.s5msmrsr�su��D 2 � SMOKE DETECTOR-DUCT EXISTING CIR5 WP EOL z[o E 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING 8. FPLP CIR6 15 CD 95 CD 95 CD 1 KB KNOX BOX EXISTING p 14 AWG $ 2COND 2 y FLOW DETECTOR/SWITCH EXISTING 'E FPLP ° Q, Ey A 531:2 O. E E b: CIR7 15 CD 15 CD 150 CD 30 CD 135 CID �O k6C1S1'E93' is EOL - I HP HIGH AIR PRESSURE SWITCH EXISTINGfSJOy,ALy.C' 14 AWG C b= 2 LOND &€ FPO ® LOW AIR PRESSURE SWITCH EXISTING J5. ORB30CD 75CD 75CD = EOL 2 00 D 11 VALVE-GENERAL EXISTING 8 2 CON FPLP p p CIR9 95 CD 7s co oCo 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING 14AWG EOL E 5 E 2 COND g^ FPLP CIR10 75CD 115CD 115CD PPP EOL FIRE PUMP 8§ 2COND C C C E RTU1 RTU2_�_ - FPLP DG1 MD1 M02 M03 �M04 M05 1 FM06 M0/ o02 MOB M09 MID #1 ClRii SLC LOOP A S F I I I S AD GENERAL NOTE EOL SPARE 18 AWS/2 COND,FPLP I11 ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. 74 AWG P0"Ta PuuNINNG REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. 2 COND NO CFIANGES TO FACU EXISTING NOTIFICATION APPLIANCE CIRCUITS I S EOL I 8 EOL c5 C6 C7 CB Cs clo clo FPtP T2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP TO EXISTING NOTIFICATION APPLIANCES, CIR4 EOL EOL EOL CALCULATIONS. E4 D0 NOT MODIFY CIRCUIT. 1 CA I__Rom_J -R�_ L J 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD d ONG FPLP VERIFIED. s= 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 $ NAC#1 (NATIONAL ELECTRIC CODE). FL PSI O M26 M25 M24 M13 5)WHERE CONDUIT 15 REQUIRED,MINIMUM SIZE SHALL BE 3/4". s TO EXISTING NOTIFICATION aPPupncEs. OR3 10 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE R 00 NOT MODIFY CIRCUIT. 14 AWG PATH, 2 COND EOL 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE e EOL . FPtP ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. BATTERY BATTERY sz1 D D MZD D role G D CABLES TURNS SHALL BE ROUTED AT 90 DEG,ANGLES TO THE BUILDING.NO g 11V 7AH 12V 7AH M2 1 m1 a + +nu� > a C< D< � M I rn I m DIAGONAL RUNS ARE PERMITTED. 2 ,CIR2. � � � � � 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. "y g DEDICATED 120 VAC TO EXISTING NOTIFlCATIONAPPUANCES. EOL EOL EOL EOL EOL EOL EOL EOL EOL EOL @= 20 NAP CIRCUIT(LOCKED) DO NOT MODIFY CIRCUIT. 14 AWG ISSUE LOG: (BY OTHERS) 2 CON D Dn/E IKI01 S•. FPIP M29 AGO M31 DDD1 Oa/a5/zs Pa POPOM uvw y5y �M-28 F F wan D D 5HOP PPAAn q• CIR1 - �M-27TO IXi5TING NmIFlCATIDN APPLIANCES.DO NOT MODIFY CIRCUIT. tq AWG y g 2 COND F FPLP ' •a WIRE CHART -cr cz c3 cq p CIRCUIT ,MIANDTYPE ONIMUMF WIRE Sli --..-- ---. --.. TYPE SYMBOL CIRCUIT DESCRIPTION - E 8 FAA SIGNALING LINE CIRCUIT - A SLC (POWER LIMITED) 2418AWG 8 m CON FIRE LITE gFPLPO \\<3`/ ANNUNCIATOR DATA BUS b ES-20OX \ AD ANN (BLK/RD=DATA) 4-#18AWG a TG-7FS-V BASIC SYSTEM FUNCTIONAL 6 TRIP CIRCUIT (WHT/GRN=PWR) t FACU u CELL OPERATION NOTIFICATION APPLIANCE TRIP CKT. MCBL-7 UNIT C TRIP 2-#14AWG e a (COMBINED HORN B VISUAL CIRCUIT) gE SS TG-7FS-V U.L.LISTED CENTRAL STA'NON WHEN A FIRE ALARM CONDITION (ALARM, SUPERVISORY OR TROUBLE) ISSCH DETECTED,THE FIRE ALARM CONTROL UNIT GOES OFF-HOOK TO DIAL THE INITIATING DEVICE CIRCUIT - H BATTERY BATTERY JOH EXPOSIIOROLS D IDC N 2-#i BAWL 14200 E EXPOSITION BLVD. CENTRAL STATION.THE DIALER CAPTURE MODULE DETECTS THE THE FIRE (ON-INTELLIGEN7 DEVICES) `c 12V 12aH 12V 12AH MCBL-7 CONDITION AND PROVIDES THE FIRE PANEL WITH A DIAL TONE WHEN THE FIRE g° ® AURORA,CO 80012 PHONE PANEL DETECTS THE DIAL TONE,IT BEGINS DIALING THE CENTRAL STATION.THE P POWER 24V NOWRESETTABLE POWER 2414AWG eR 1.800428J124 DIALER CAPTURE MODULE CONSIDERS THE THREE SECOND PERIOD AFTER "AW4my y HArf' ;< 2D AMP CIR UIT(LOc EDI DIALING AS THE NUMBER DIALING HAS BEEN COMPLETED.AFTER THE DIALING 15 L RT TEST REMOTE TEST STATION TEST 4-1118AW1 (BY OTHERS) SS000672 COMPLETED,THE DIALER CAPTURE MODULE RETURNS A HANDSHAKE TO THE ; FIRE PANEL.THE FIRE PANEL THEN SENDS THE CONTACT ID REPORTS TO THE 20 AMP CI CUIT(LOCED) DIALER CAPTURE MODULE,WHICH IN TURN SENDS A KISS-OFF AFTER THE $H=SHIELDED g (BY OTHERS) REPORT IS SUCCESSFULLY RECEIVED FROM THE FIRE PANEL. THE DIALER 'WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED B- CAPTURE MODULE SENDS THE CONTACT ID REPORTS TO THE COMMUNICATIONS SYSTEM MODULE.WHEN ALL THE REPORTS ARE SENT,THE FIRE PANEL GOES ON-HOOK. DOCUMENTATION THE COMMUNICATIONS MODULE THEN TRANSMITS THE MESSAGES TO THE LES SCHWAB TIRE CENTER ysR AS-BUILT DRAWINGS CENTRAL STATION. �2 E5 . 166D7 SMOKEY POINT BLVD I 8 ARLINGTON,WA 98223. �e DESIGNED BY: P.ROJAS BY: P.ROJAS €� CHECKED BY: 04/25/2025 6 JOB/CASE#: 1-917JWV1 F5 SHOP DRAWINGS fig^ RISER DIAGRAM NOTE o a DEVICE WIRING SHOWN IS CONCEPTUAL.POINT TO POINT CONNECTIONS MAY VARY.REFER TO FLOOR PLANS FOR REQUIRED EQUIPMENT LOCATIONS.THE ELECTRICAL CONTRACTOR SHALL REFERENCE EQUIPMENT s= INSTALLATION DOCUMENTS,DRAWING TERMINATION DETAILS,AND RISER DIAGRAM FOR COMPLETE EQUIPMENT INSTALLATION. SHEET, i SHOULD ANY CONFLICT ARISE BETWEEN DESIGNED PLANS,BATTERY CALCULATIONS,VOLTAGE DROPS,AND ACTUAL INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF JCI IN WRITING UPON DISCOVERY AND PRIOR To ELECTRICAL ROUGH. RISER DIAGRAM rt CALCULATIONS RISER DIAGRAM x2 B ¢s GG FA201 3b ppG� Ie 1­I...I...I.r.1 30"X42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/202512:11:12 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTCfdOngton_WA_FA_DD01_i-91 ZJWVI.dwg FIRE RATED CONCRETE BLOCKWALL FIRE RATED GPY. WALLBOARD FIRE RATED GPY. WALLBOARD CEILING TO WALL TRANSITION AND OPEN WIRING A C-AJ-1045 W-L-1001 W-L-3149 Johnson CONDUIT PENETRATION U.L.C-AJ-1045 Controls CONDUIT PENETRATION U.L.W-L-1001 JOIN SON CONTROLS i OR 2 HOUR RATED CONCRETE GLOBAL CENTER OF BLOCK WALL ASSEMBLY 3M FIRE BARRIER CP 25W6+CAULK OR EQUAL 1 OR 2 HOUR RATED GYP. Aj 3M FIRE BARRIER a2OD E,CO 80012 AVE n1aNCE WALLBOARD ASSEMBLY CP FIRE25W B CAULK OR EQUAL CABLE PENETRATION U.L.W L-3149 AURORA,co Boo12 1-8F/-330-7404 1 OR 2 HOUR RATED GYP. WALLBOARDASSEMBLY 3M FIRE BARRIER CP 25W1+CAULK OR EQUAL PACKING MATERIAL CABLE OR CONDUIT CABLE BUNDLE CENTER OF EXCELLENCE NETWORK FIRE ALARM WIRE NOTES: NOTES: NOTES: 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALLASSEMBLY. CONDUIT CONDUIT SHALL BE INSTALLED AT CENTER OF STUD CAVITY WIDTH AND KEYPLAN: 1 SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2 THE ANNULAR SPACE BETWEEN CABLEICABLE BUNDLE AND PERIPHERY OF OPENING SHALL BE 2 THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE 0 TO 1-3/8" CAULK FILL MATERIAL SHALL COMPLETELY FILL ANNULAR SPACE D TO ill. 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. BETWEEN CONDUIT AND WALL;AND WITH A WIDTH OF 1/4"DIAMETER 3 MAXIMUM OF A 1"DIAMETER CABLE BUNDLE PER FIRESTOP SYSTEM. PACKING MATERIAL-MINIMUM 4"THICKNESS OF MINIMUM 8 PCF MINERAL 2 BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS OF CAULK MATERIAL-MINIMUM 5/8"THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, WOOL BATT INSULATION SHALL BE FIRMLY PACKED INTO OPENING AS A THE WALL. FOR CONDUIT 1"DIAMETER AND SMALLER,ANNULAR SPACE 4 AT THE CI AB BOTH SURFACES LBOARD INTERFACE AT POINT CUM 112"DIAMETER LOCATION BOTH SIDES O LIE FLUSH BEAD OF CAULK APPLIED D L. 4 PERMANENT FORM. PACKING MATERIAL SHALL BE RECESSED FROM BOTH SHALL BE 0 TO 3/16". FOR CONDUIT 4"DIAMETER AND SMALLER, NOTES: SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED ANNULAR SPACE SHALL BE 0 TO 1-1/2". 5 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. THICKNESS OF CAULK MATERIAL, 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. 1 CONDUIT SHALL BE USED FOR ALL EXPOSED FIRE ALARM CABLING INSTALLED BELOW JOISTS AND BEAMS. 5 CAULK MATERIAL-MINIMUM 1/2"THICKNESS OF FILL MATERIAL SHALL BE 4 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. 2 CONDUIT SHALL BE A MINIMUM OF 3/4". APPLIED WITHIN THE ANNULUS,FLUSH WITH BOTH SURFACES OF THE WALL. CONTACT INFORMATION: DEVICE MOUNTING HEIGHTS POWER DISCONNECT DROP CEILING Et J BOX PHONE CONNECTION DEVICE MOUNTING HEIGHT REFERENCE(PER NFPA 72) I monwn°exz� nawrx DMARC } 1-0115—DEVICE LINE i+T+I ux.+surFMExn RJ 31X BLOCK RED GREEN FIRE AWUI PANEL FIRE 4LAflu,PANEL BLACK s m,ry aer°m"xrs x YELLOW RJ CORD RJ 31X BLOCK }s my.uus uxeu,z — sxnu eervmu�rlireceuxe roexx 000R e°nw, =o�� ± �!oD musaumsunsxoxm � � LINE TO PHONES �ANPP 1 yII 1 �Quo El 1—Er rxe RED F BwxTM w xrin To enovr rixls an anon nr,cnrcr MTAGON JUN TION E. GREEN I I TELCO LINE GIBBENS DRAKE:SCOTT,LNC BLACK sv esiREe B1 Txan iu exrae=°orview BDsalPrlou 90� CONDUIT RJ CORD xAreOwN,narssotin:Hl±±xx _ �Auun ruusrnn oN DISTRIBUTION PANEL YELLOW Asr Nwu l+°e a na•a;"MF..NnLN,Em IIIIII IIIIII OR RJ CORD — 0 o N .PFA—TRO=°. pro IIIIIIIII O IIIIIIII( .x M.x ern=.,ax��con.o=r.,xc ,wx w,", IrL�IIL7 col+DNrt 4 z 2 z Cr=• TA4 cRwnaN +' PRIMARY PORT CEPIICIRCUTATREALOCKED b —11—Ell 11T11 Ill— go weu KER FIRE ALARM DISCONNECT TO DEDICATED LOCKED BRANCH E ToaRculr lzB vpuzOAMP souacE O 4G15'iti'N '' E mrnnusr rnrr o-r,F sworcr mrcron..c PRIMARY PORT SECONDARY PORT NMI BURGLAR PANELHEAT C11CFOR '-Sy Tx—T s°ceor ne s"Des macron ac OOO FIRE ALARM PANEL SQUARE _ orncauuc ITI.}x, LUNCTIC,ox .",�io - - a•F- •� 7 fe- - I• -} - rill joixwxpoe a.�cPP° 'crow iie?�i ouiiocu�ixm�oW ciiuNe €62 DEVICE WIRING STROBE - HORN/STROBE DEVICE WIRING AUDIBLE DEVICE WIRING OS&Y TAMPER SWITCH GATE VALVE WATERFLOW Et BUTTERFLY TAMPER SWITCHES `BF �a1a°coNDmr R€ g€ i nr..aR : Rw:Po FLOW S}yITCH S a£ ,zs°,C Anu,arax[aeWrvueNrl �t BREAK WIRE s" BREAK WIRE DO NOT LOOP 1 rz•wP FIEx coNDurt a€ ( r FIRE RATED DO NOT LOOP / sPaINKLta wsEx CABLE STROBE STROBE/HORN + .n O O �= PRECEDING HORN _ \ OR EDE CONDUIT ,2 1-N 0 RESISTOR + + OR POWER SUPPLY 4Raaxw�EGyER NEXT HORN OR EOL a AT LAST FIRE RATED CABLE Q' 0' DEVICE PRECEDING OR CONDUIT EOL BREAK WIRE o FROM STROBEST DO NOT LOOP p swcn,�,m BurrERav TawER SWITCH RESISTOR . � gDEVICE OR SUPPLY AT LAST + rz•wP xcoNDUIT $ DEVICE g s � ISSUE LOG: & PRECEDING STROBE xx,N,r Nnxur ate" —N —1 INT DESCRIPTION _ Pow OR POWER SUPPLY NEXT STROBE OR EOLPRO —11 WAUL _s NOTES: v$ 3X o� €^c $q FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION HEAT DETECTOR Ev CELL-CAB-FL HONEYWELL HWF2-COM TELGUARD TG-7FS 5601P €_ A=3 1l2"Octagonal box B=4"Octagonal box 5 C G=Single 0: 4"square With gangD.Z boz antl flu-EUlla .r ring °g ANTENNA 1MI�Ipl1�1 Y D=Directly to WaILICeiling o w�MP->t REMOTE SURFAC&fAOUNT p d e ANTENNA INCOMING 0 e o P R TELco A D y 5 N U TE PHONE E BATTERY WIRING i p F, SHOULD BE AT LEAST ©� © B E� °0 1/4"APART FROM AC 0 © 8= WIRES O B V � A ,�! LES SCHWAB TIRE CENTER ms O ® ! �•� BATTERY DIGITAL TG-7F5 e A FLUSH-MOUNT goaeTo O + � ❑ D t O tocrcwaSHEan NT n,11I r D 00 rxcr°,�°,`,°� ALARM PANEL IM WIHDa Diagram-Siaala OlrauKM h,: 16607 SMOKEY POINT BLVD. xe O ARLINGTON,WA 98223. 5 p •Off, 0 (N.C.) O ® $ STC1 TAMPER ,J 4 E C�niro Auxiliary DESIGNED BY: P.ROJAS o U aTBtOM e�nx U 3 2_ Panal OR (N.O.) SWITCH R S IE-„a- D a� CONNECTOR _ DRAWN BY: P.ROJAS ssIf - CHECKED BY: 04/26/2026 I,ISE O O O EARTH GROUND JOB/CASE k: 1-912JWV1 AMP 0 IM L AC(12V BOOMA) wiHaa Diaaeam-Bum ciRmt Mogul.: = _ 7ANBATTERY CONNECTOR p TRIP INPUT reinstall tloor O O + H P DRAWINGS Co.. EOL OR Auxiliary Auxiliary g NOTE:WHEN USING THIS SCHEME,THE USE OF THE PRIMARY OR SECONDARY DIALER TO Panel Auxiliary Auxiliary Device Device a e NOTE:THE CELL-MOD(C)/CELL-CAB-FL OFFERS AN OPTIONAL GSM COMMUNICATOR CARD FOR CENTRAL STATION REPORTING.IT MOUNTS CONNECT TO TELCO IS WHAT DETERMINES WHETHER THE TG-7 IS MEANT TO WORK AS A Device Device SHEET: IN ITS OWN PLASTIC ORMETAL ENCLOSURE.USE OF THE CELL-MOD(C):CELL CAB FL REQUIRES THE IPOTS-COM COMMUNICATOR. BACK-UP OR PRIMARY COMMUNICATOR. USE EITHER AC POWER(FROM ADAPTER)WITH BATTERY OR USE DC POWER(FROM PANEL). 0 PRODUCT TYPICALS PRODUCT TYPICALS o FA301 o �a I I•r•I• I I 30"X 42'-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:14 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_ArttngtoD_WA_FA_DD01_1-91ZJWV1.Owg Johnson Controls PRODUCT DATA SUBMITTAL FIRE ALARM SYSTEM PRODUCT DATA SUBMITTALS PREPARED FOR: 1Es semwAB7 Les Schwab Tire Centers 16607 Smokey Point Blvd. Arlington, WA 98223 GIBBENS DRAKE SCOTT, INC 9201 E.63rd STREET,SUITE 100 0 a RAYTOWN,MISSOURI 64133 H / � 53I?2 � (,• ENGINEERING � �GtS1�� Ci4 Ss�U`A.1. `'' Prepared By: "aa as JOHNSON CONTROLS INTERNATIONAL 14200 E. EXPOSITION AVE., AURORA, COLORADO 80012 Johnson Controls I Product Information Table of Contents Item # Fire Alarm Control Panel & Panel Components 1 ES-20OX FIRE ALARM CONTROL PANEL 2 ANN-80 FIRE ALARM ANNUNCIATOR 3 TG-7FS-V CELL DIALER COMMUNICATOR 4 HPF-PS10 FIRE ALARM POWER SUPPLY 5 1 SS000672 IFIRE RECORDS DOCUMENT BOX Initiating Devices 6 1 SD365 JINTELLIGENT PHOTO SMOKE DETECTOR 7 1 BG-12LX IINTELLIGENT MANUAL PULL STATION Supervising Modules, Relays and Ancillary Equipment 8 MMF-300 INTELLIGENT MONITOR MODULE 9 MMF-300-10 INTELLIGENT 10-INPUT MONITOR MODULE 10 CRF-300 ADDRESSABLE CONTROL MODULE 11 MDF-300 DUAL INTELLIGENT MONITOR MODULE 12 DTK-120HW 120 VAC SURGE SUPPRESSOR Notification Appliances 13 SRLED MULTI-CANDELA WALL MOUNT STROBE RED 14 PC2RLED MULTI CANDELA CEILING MOUNT HORN STROBE RED 15 P2RLED MULTI CANDELA WALL MOUNT HORN STROBE RED 16 P2RK MULTI-CANDELA WALL MOUNT HORN STROBE WEATHERPROOF RED D F-60957:C Es-Zoox FIre.LiTeALarms Intelligent Addressable FACP with Communicator by Honeywell Addressable Fire Alarm Control Panels General The ES-20OX is the latest intelligent addressable Fire Alarm Control Panel (FACP)from Fire-Lite Alarms and is a direct replacement for the MS-92000DLS. The ES-20OX comes with a pre-installed com- municator and supports up to 198 addressable devices (99 detec- tors and 99 modules).With an extensive list of powerful features,the ES-20OX programs just like Fire-Lite's other addressable products, yet fits into applications previously served only by conventional pan- els. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator.The POTS transmits system status(alarms,troubles, AC loss, etc.)to a Central Station via the public switched telephone network.The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines.Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line.Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- Alarm verification selection per detector point ages by means of a USB flash drive. Maintenance alert warns when smoke detector dust accumula- The power supply and all electronics are contained on a circuit tion is excessive board supported on a new quick install chassis and housed in a One-person audible or silent walk test with walk-test log and metal cabinet. Available accessories include local and remote printout upload/download software, remote annunciators, and reverse polar- System alarm verification selection per detector point ity/city box transmitter(4XTMF). PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA Features 72 compliant) • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus • Listed to UL Standard 864, 10th edition Remote Acknowledge, Alarm Silence, Reset and Drill via • Pre-installed IPOTS-COM Ethernet IF and POTS(Plain Old Tele- addressable modules or remote annunciator phone Service)Central Station Communicator over AlarmNet Upload/Download of program and data via USB with optional FS- • Optional CELL-MOD or CELL-CAB-FL GSM Central Station Tools Programming Utility Communicator over AlarmNet® • Automated activation of the ECC-50/100 Emergency Command SLC COMMUNICATION LOOP Center Supports LiteSpeedTm and CLIP protocols • ECC-FFT Firefighter Telephone option SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with • Compatible with SWIFT®wireless devices twisted, unshielded wire • Auto-programming (learn mode) reduces installation time. Single addressable SLC loop which meets NFPA Class B and Reports two devices set to the same address Class A requirements • Four built-in, independently programmable Style Z (Class A) or Style Y(Class B)NAC circuits 198 addressable device capacity (99 addressable detectors and • Selectable strobe synchronization for System Sensor, Wheelock, 99 modules) and Gentex devices Compatible with Fire-Lite's addressable devices (refer to the • Notification Appliance Circuit End of Line resistor matching SLC Wiring Manual) • Four programmable function keys for ease of maintenance NOTIFICATION APPLIANCE CIRCUITS(NACS) • Two programmable relays and one fixed trouble relay • Built-in Programmer Four independently programmable output circuits.Circuits can be • Integral 80-character LCD display with backlighting configured for the following outputs: • Real-time clock/calendar with automatic daylight savings control —Style Y(Class B) • History file with 1,000 event capacity —Style Z(Class A) • Addressable sounder base compatibility Silence Inhibit and Autosilence timer options • Multi-criteria detector (smoke, heat, CO) with programmable Continuous, March Time, Temporal, or California code for main response circuit board NACs with two-stage capability • Control module delay timer Selectable strobe synchronization per NAC • Automatic detector sensitivity testing(NFPA 72 compliant) • Automatic device type-code verification 2.5 A special application,250mA regulated,total power for NACs • Point trouble identification NOTE:Maximum or total 24VDC system power shared between all NAC • Waterflow selection per module point circuits and the ANN-BUS is 2.7 A DF-60957:C•7/16/2018—Page 1 of 4 firealarm resources.com PROGRAMMING AND SOFTWARE PRN Series: UL listed compatible event printer. Uses tractor-fed • Autoprogramming(learn mode)reduces installation time paper. • Custom English labels (per point) may be manually entered or OPTIONAL MODULES selected from an internal library file • Two programmable Form-C relay outputs 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and • 99 software zones trouble. Includes a disable switch and disable trouble LED. • Continuous fire protection during online programming PWRMOD24 Power Expander Module: Optional power module. • Program Check automatically catches common errors not linked Increases alarm power output to 6 amps. to any zone or input point COMPATIBLE ANNUNCIATORS • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools,a Windows®-based software package,and ANN-80: Remote LCD annunciator mimics the information dis- upload/download system programming locally. Offline program- played on the FACP LCD display. Recommended wire type is un- ming requires an ethernet connection. FS-Tools is available on shielded. www.firelite.com. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- User interface shielded. For use in FM applications only. LED INDICATORS ANN-1/0: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) • Fire Alarm (red) ANN-LED:Annunciator Module provides three LEDs for each zone: • CO Alarm(red) Alarm,Trouble,and Supervisory.Ships with red enclosure. (See DF- • AC Power(green) 60241.) • Supervisory(yellow) ANN-RLED: Provides alarm(red)indicators for up to 30 input zones • Trouble(yellow) or addressable points. (See DF-60241.) • Ground fault(yellow) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) • Battery fault(yellow) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- Disabled(yellow) nection for a serial or parallel printer. (See DF-52429.) • Maintenance(yellow) ADDRESSABLE DEVICES • Communication(yellow) All feature a polling LED and rotary switches for addressing. • Alarm Silenced (yellow) SD365: Addressable low-profile photoelectric smoke detector. Lite- • F1-F4 Programmable Function Keys(yellow) Speed only. KEYPAD SD365-IV: Addressable low-profile photoelectric smoke detector. • 16 key alpha-numeric pad Ivory. LiteSpeed and CLIP mode. • Acknowledge SD365T:Addressable low-profile photoelectric smoke detector with Alarm Silence thermal sensor. LiteSpeed only. • SD365T-IV: Addressable low-profile photoelectric smoke detector • Drill (Manual Evacuate) with thermal sensor. Ivory. LiteSpeed and CLIP mode. • Four(4)programmable function keys SD365R: Remote test capable addressable photoelectric smoke • Reset(lamp test) detector for use with DNR(W)duct detector housing.LiteSpeed only. PRODUCT LINE INFORMATION SD365R-IV: Remote test capable addressable photoelectric smoke ES-20OX:Addressable Fire Alarm Control Panel with one SLC loop. detector for use with DNR(W) duct detector housing. Ivory. Lite- Includes main circuit board with display, pre-installed communicator, Speed and CLIP mode. chassis with transformer, backbox with door, plastic bag containing H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. screws, cables, key,etc. (For ES-200XC, refer to DF-60958.) H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed FS-Tools: Programming software for Windows®-based PC com- and CLIP mode. puter.Available for download at www.firelite.com. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- CELL-CAB-FL/CELL-MOD: Optional GSM communicators. Speed only. IPOTS-COM: Dual technology (POTS and IP) communicator. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. (replacement board) LiteSpeed and CLIP mode. DP-ES-R: Optional dress panel for the ES-200X. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. TR-CE: Optional trim ring for semi-flush mounting. LiteSpeed only. BB-2F: Optional cabinet for one or two modules. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 Ivory. LiteSpeed and CLIP mode. chassis. Legacy Devices BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- CP355:Addressable low-profile ionization smoke detector. 75. SD355:Addressable low-profile photoelectric smoke detector. BB-55F: Battery box, houses two 55 AH batteries SD355T:Addressable low-profile photoelectric smoke detector with CHS-6:Chassis,mounts up to six multi-modules in a BB-6F cabinet. thermal sensor. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to SD355R: Remote test capable addressable photoelectric smoke 75 AH. detector for use with DNR(W)duct detector housing. CHG-120F: Remote battery charging system for lead-acid batteries SD355CO: Addressable, low-profile device that provides fire, heat, with a rating of 55 to 120 AH. Requires additional BB-55F for mount- and carbon monoxide(CO)detection. ing. BAT Series: Batteries,see data sheet DF-52397. H355: Fast response, low-profile heat detector. Page 2 of 4—DF-60957:C•7/16/2018 firealarm resources.com H355R: Fast-response, low-profile heat detector with rate-of-rise SW/FT Wireless Devices option. W-GATE: LiteSpeed Wireless Gateway H355HT: Fast-response, low-profile heat detector that activates at W-SD355: LiteSpeed intelligent,wireless photo detector. 190'F/88'C. W-H355R: LiteSpeed intelligent wireless rate of rise(135°) heat AD355: Low-profile, intelligent, "Adapt' multi-sensor detector detector. (13350LP base included). W-SD355T: Intelligent wireless photo/heat detector. B20OS: Programmable, addressable sounder base. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) B200SR:Addressable sounder base. heat detector. BEAM355: Intelligent beam smoke detector. W-MMF: LiteSpeed Intelligent wireless monitor module. BEAM355S: Intelligent beam smoke detector with integral sensitiv- W-CRF: LiteSpeed Intelligent wireless relay module. ity test. W-BG12LX: LiteSpeed Intelligent wireless pull station. D355PL: InnovairFlex low-flow non-relay duct-detector housing; WAV-RL,WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV includes SD355R. bases. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order W-USB: Wireless USB radio/antenna dongle that plugs into the SD355R/SD365R separately.) USB port of a PC running SWIFT Tools. DNRW: InnovairFlex low-flow non-relay duct-detector housing, with SWIFT Tools: Programming and diagnostic utility for the Wireless NEMA-4 rating.Watertight.(Order SD355R/SD365R separately.) Gateway and devices.Available for download from firelite.com. Addressable Modules NOTE: For more information on Compatible Addressable Devices for MMF-300: Addressable Monitor Module for one zone of normally- use with the ES-200X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 open dry-contact initiating devices. Mounts in standard 4.0" (10.16 (DF-52386), BG-12LX(DF-52013), CMF-300-6 (DF-52365), CRF-300-6 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 ule may be configured for either a Style B(Class B)or Style D(Class Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 A)IDC. Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- (DF-52356), SD355ISD355T (DF-52384), and SLC Wiring Manual vides two Style B(Class B)only IDCs. (51309). MMF-301: Miniature version of MMF-300. Excludes LED and Style NOTE:Legacy 300 Series detection devices such as the CP300/CP350, D option.Connects with wire pigtails. May mount in device backbox. SD300(T)/SD350(T)and older modules such as the M300, M301, M302, MMF-302: Similar to MMF 300.Addressable Monitor Module for one C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard zone of conventional two-wire detectors. Requires resettable 24 CLIP protocol. Please consult factory for further information on previous VDC power. Refer to the Device Compatibility Document for listed 300 Series devices. compatible devices and quantity limitation. ADDRESSABLE DEVICE ACCESSORIES CMF-300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts End-of-Line Resistor Assembly (R-47K and R-3.9K): The directly to a 4.0" (10.16 cm.) electrical box. NAC option requires 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, external 24 VDC to power notification appliances. and CMF-300 module circuits. The 3.9k ohm assembly supervises CRF-300: Addressable relay module containing two isolated sets of the MMF-302 module circuit. These resistors are included with each Form-C contacts, which operate as a DPDT switch. Mounts directly module. to a 4.0"(10.16 cm.)box,surface mount using the SMB500. Power Supervision Relay: Supervises the power to 4-wire smoke BG-12LX: Addressable manual pull station with interface module detectors and notification appliances. mounted inside. Wiring Requirements 1300:This module isolates the SLC loop from short circuit conditions While shielded wire is not required, it is recommended that all SLC (required for Style 6 or 7 operation). wiring be twisted-pair to minimize the effects of electrical interfer- ISO-6: Six-fault isolator module. Mount one or two modules in a ence. Refer to the panel manual for wiring details. BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except the MMF-301 and M 301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module(Form-C relays). Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. DF-60957:C•7/16/2018—Page 3 of 4 firealarm resources.com SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Intelligent Signaling Line Circuits................................................1 This system meets NFPA requirements for operation at 0—49°C/32 • Addressable device capacity..................................................198 —120°F and at a relative humidity 93%±2%RH(noncondensing)at Programmable software zones.................................................99 32°C ± 2°C (90oF ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely • Annunciators.............................................................................16 affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in Electrical Specifications an environment with a normal room temperature of 15—27°C/60— AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, 80oF. auto-sensing- no switch required. Wire size: minimum 14 AWG NFPA Standards (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger The ES-20OX complies with the following NFPA 72 Fire Alarm Sys- Capacity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH tems requirements: batteries.) —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- Communication Loop: Supervised and power-limited. sory). Notification Appliance Circuits: Terminal Block provides connec- —AUXILIARY (Automatic, Manual and Waterflow) (requires tions for four NACs, Style Y(Class B)or Style Z (Class A). Special 4XTMF). Application power. Power-limited, supervised circuitry. Maximum —REMOTE STATION (Automatic, Manual and Waterflow) signaling current per circuit: 2.5 amps special application, 250mA (Where a DACT is not accepted,the alarm,trouble and supervi- regulated. End-of-Line Resistor: 4.7k ohm, % watt (P/N 71252 UL sory relays may be connected to UL 864 listed transmitters. For listed)for Style Y(Class B)NAC; system capable of 1.9 kQ-22 kQ reverse polarity signaling of alarm and trouble, 4XTMF is ELR range. Refer to the Fire-Lite Device Compatibility Document for required.) listed compatible devices. —PROPRIETARY(Automatic, Manual and Waterflow). Two Programmable Relays and One Fixed Trouble Relay: Con- —CENTRAL STATION (Automatic, Manual and Waterflow, and tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Sprinkler Supervised). Form-C relays, non-power-limited, non-supervised. —OT, PSDN (Other Technologies, Packet-switched Data Net- work) Cabinet Specifications —IBC 2012,IBC 2009, IBC 2006,IBC 2003, IBC 2000(Seismic). Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" —CBC 2007(Seismic) (1.82 cm.)deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" Agency Listings and Approvals (55.88 cm.)high x 19.65"(49.91 cm.)wide. The listings and approvals below apply to the basic ES-20OX control panel. In some cases, certain modules may not be listed by certain Shipping Specifications approval agencies, or listing may be in process. Consult factory for Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high latest listing status. x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. UL: S624 • FM approved • CSFM: 7165-0075:500 • FDNY: COA#6261 NOTE:See DF-60958 for ULC-listed model. AlarmNet@, Fire-Lite@ Alarms, SWIFT@, and System Sensor@ are registered trademarks of Honeywell International Inc.Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING S MANUFACTURING QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www.firelite.com Page 4 of 4—DF-60957:C•7/16/2018 firealarmresources.com df-52417:c•B-90 ANN-80 Flrelffe Marms 80-Character LCD Serial Annunciator by Honeywell Annunciators General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions.The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed,filtered power supply. ANN-80 is red;for white,order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features • Listed to UL Standard 864,9th Edition. • Backlit 80-character LCD display(20 characters x 4 lines). • Supervisory • Mimics all display information from the host panel. • Alarm Silenced • Control switches for System Acknowledge, Signal Silence, Drill,and Reset. Specifications • Control switches can be independently enabled or disabled • Operating voltage range: 18 VDC to 28 VDC. at the FACP. • Current consumption @ 24 VDC nominal(filtered and non- • Keyswitch enables/disables control switches and mechani- resettable):40 mA maximum. cally locks annunciator enclosure • Ambient temperature:32°F to 120°F(0°C to 49°C). • Keyswitch can be enabled or disabled at the FACP. • Relative humidity: 93%±2% RH (noncondensing) at 32°C • Enclosure supervised for tamper. ±2'C(90°F±3°F). • System status LEDs for AC Power, Alarm, Trouble, Supervi- • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" sory,and Alarm Silence. (3.49 cm.)deep. • Local sounder can be enabled or disabled at the FACP. • For use indoors in a dry location. • ANN-80 connects to the ANN-BUS terminal on the FACP and • All connections are power-limited and supervised. requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- Agency Listings and Approvals ble,supervisory,zone,and custom alpha labels. • Time-and date display field. The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval • Surface mount directly to wall or to single, double, or 4" agencies, or listing may be in process. Consult factory for latest square electrical box. listing status. • Semi-flush mount to single, double, or 4" square electrical . UL: S2424 box. Use ANN-SB80KIT for angled view mounting. • Can be remotely located up to 6,000 feet(1,800 m)from the FM approved panel. • CSFM: 7120-0075:211 • Backlight turns off during AC loss to conserve battery power • MEA:442-06-E but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote The ANN-BUS power supply(requires 24 VDC). • Up to eight ANN-80s can be connected on the ANN-BUS. POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY Controls and Indicators The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the • AC Power ANN-BUS power requirements. See the FACP manual for more • Alarm information. • Trouble df-52417:c•05/22/09—Page 1 of 2 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw, the following Each ANN-BUS device requires a unique address (ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP A maximum of 8 devices located from the FACP on a single wire run. The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum. In general,the wire length is lim- See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk (`). Maxi- The ANN-80 connects to the FACP ANN-BUS communications mum length can never be more than 6,000 feet (1,800 m), circuit. To determine the type of wire and the maximum wiring regardless of gauge used. See table below. distance that can be used with FACP ANN-BUS accessory mod- WIRE REQUIREMENTS: POWER CIRCUIT ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0.75 -2.08 mm2)wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. Power wire distance limitation is set by 1.2 case currents for each module. volt maximum line drop form source to end of circuit. NOTE: For total worst case current draw on a single ANN-BUS • All connections are power-limited and supervised. refer to appropriate FACP manual. • A maximum of eight ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. '6,000 ft. '6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80: Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SB80KIT R: Red surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB80KIT W: White surface mount backbox with angled ® B A + - wedge. TB1 4 3 2 1 ANN-BUS Device + A B O MS-905OUD TB3 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device FireLite®Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-52417:c•05/22/09 TG , 7FS CELLULAR ALARM COMMUNICATOR TELGUARD LTE - V FOR LTE NETWORKS .kMETEIC t�1 COMMERCIAL FIRE PRODUCT FEATURES F Certified for use on Verizon's LTE network for sunset-free installations. II• Meets UL 864 requirements for sole, primary or backup path communications. II• Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS CDMA transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LTE-V can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new five or sixty minute supervision modes. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. TeIguard Portal TeIguard Cellular Service Advanced Reliability providesTeIguard makes adopting cellular TeIguard Cellular Service portal.easy with a secure Internet - The straightforward web interface for all TeIguard units. - • reduce allows security dealers and central Communication Center is UL false alarms. stations o quickly and efficiently compliant and . . betweenaccess TeIguard based services 24/7. connectivity This advanced .. user authorization d provides products - central station. controltotal account management of TeIguard Technical Support provides . Available relay output for tripping UL Listed TeIguard cellular alarm a single point of contact for both the alarm panel communicators. cellular service and TeIguard product trouble condition occur questions. TG , 7FS CELLULAR ALARM COMMUNICATOR TELGUARD LTE - V FOR LTE NETWORKS AMETEK° Power:Power Transmit LWEa Telguard IWI •• •. • Net'War Communication ce Center • Power Consumption: Alarm Panel TG-]FS Central Station Fire 41 •• LTEN •• • with ' L-dline supervision (OPtionan • Source: 8OOmA UL listed plug-in transformer •'• Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for Radio superior in-building penetration. . Antenna: • dipole with 2dBiTelguard products are easy to install, economical, and UL Listed. cable and universal mounting bracket. Accessories .. • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. Physical Details • HGD-0: High gain directional antenna. • EXD-0: External antenna. Shipping8lbs. Operating •• +50OC; up to 95% humidity (non-condensing). Standard - UL Listings Commercial Fire Commercial Burglary Residential Full data reporting. 864 • Control units& 365 Police Station 985 Household fire accessories for fire connected burglar warning systems Automatic alarm systems alarm units and 1023 • Household burglar • minute,•• • daily). systems alarm systems Power •• battery harness. 1610 Central station burglar Locking, _• metal enclosure. alarm units; Two programmable supervisory Line security servcies trip outputs. For the most current product specifications and UL Listings visit www.Telguard.com. Supports • (Contact • and others) usin ial pane• •• •. •capture • universal SIGNALING Do Telephone • monitor • • �� ELECTRONIC :O• SECURITY verizon� with Standard NFPX+rvtok // ASSOCIATION'" network certified ���� Executive Strategic Partner LISTED INTERNATIONAL GOIA Telguard,a Division of Telular Corporation • 3225 Cumberland Blvd SE •Suite 300 •Atlanta,GA 30339 • USA 800.229.2326 I telguard.com •Copyright©2019 Telguard,a Business Unit of AMETEK, Inc. •All Rights Reserved 072019R.vX �J NOT 1 F 1 E R° by Honeywell HPF-PS6/HPF-PS10 Series 6/10 Amp, 24 Volt Power Supplies General The HPF-PS Series is a remote power supply line from Honeywell and is a direct replacement for the PSE and FCPS Series. The HPF-PS6(B)(E) is a 6 amp and the HPF-PS10(B)(E) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a stand- alone power supply.The HPF-PS Series provides 24 VDC power for NACs(notification appliance circuits)configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync pro- tocol options. The HPF-PS Series also provides auxiliary power, constant or resettable,suited for detectors,annunciators, door hold- ers, and other fire alarm system peripherals. The HPF-PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to m 33 AH batteries in a separate cabinet. The HPF-PS6E and HPF-PS10E are models rated for 240V operation. Features • Up to five(6 amp model)or seven(10 amp model)independently- configurable, power-limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non-resettable 24V auxil- iary power —door holder power • Converts from Class B to Class A wiring without losing any out Battery charger may be disabled via DIP switch for applications puts using the ZNAC-PS converter card(sold separately) requiring larger batteries and external battery charger • Optimal for powering four-wire smoke detectors, annunciators, Removable terminal blocks accommodate up to 12 AWG and other system peripherals requiring regulated power (3.1 mm2)wire • Configurable for ANSIO Temporal 3 or Temporal 4 coded output Works with any UL 864 FACP which utilizes an industry-standard • UL-Listed NAC synchronization using System Sensor@, Whee- reverse-polarity notification circuit lock@, Gentex0,or AMSECOO appliances Optional devices include addressable control, monitor, and relay • Synchronization can be triggered from FACP NAC/remote sync modules and power-supervision relay(EOLR-1) outputs, cascaded power supply, or a control module, single or multi,which may be housed within the power supply cabinet Standards and Codes • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model)fully-isolated input/ The HPF PS Series comply with the following standards: control circuits which can be programmed to any output • NFPA 72 National Fire Alarm Code • Two Form C normally-closed trouble relays for AC Trouble and • UL 864 Standard for Control Units for Fire Alarm Systems (NAC General Trouble, Ground Fault relay available on Canadian mod- expander mode), 10th Edition els only • UL 1481 Power Supplies for Fire Alarm Systems • 6 or 10 amp full load output, respectively, with 3 A maximum/cir- . IBC 2009(when using SEISKIT-MULTI-1) cuit • CBC 2007(when using SEISKIT-MULTI-1) • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support Agency Listings and Approvals • Wide range end-of-line supervision value(normal:2K-27K ohms) These listings and approvals apply to the modules specified in this • Selectable earth fault detection(enable or disable) document. In some cases, certain modules or applications may not • AC trouble report delay timer be listed by certain approval agencies, or listing may be in process. • Completely configurable via onboard DIP switches, no extra soft- Consult factory for latest listing status. ware required • UL Listed:S24562(HPF-PS/E Series), • Self-contained in compact, locking cabinet constructed of heavy S635, S674(PSE Series,discontinued) gauge steel with a corrosion-resistant powder coat chip and . ULC Listed: S24562 (HPF-PS Series), scratch-resistant finish S635(PSE-6C/PSE-10C discontinued) • Cabinet designed with ten double knockouts and a removable • CSFM Approved:7315-1637:0505(HPF-PS Series), door for ease of installation and wiring 7315-0028:0513(PSE Series,discontinued) • Includes integral battery charger capable of charging up to 33 AH • FDNY COA:2022-TMCOAP-002231-AMND (HPF-PS Series), batteries 2021-TMCOAP-001761-CERT(PSE Series,discontinued) • Cabinet can house two 7 AH or 18 AH batteries • FM Approved DN-610920•8/15/2023—Page 1 of 2 SPECIFICATIONS Primary(AC)Power: Ordering Information • HPF-PS6(B): 120 VAC, 50/60 Hz,5.OA maximum HPF-PS6: 6.0 A, 120 VAC remote charger power supply in a lock- • HPF-PS10(B): 120VAC,50/60 Hz,6.2 A maximum able, metal enclosure, red • HPF-PS6E:240 VAC,50/60 Hz,2.7A maximum HPF-PS6B: 6.0 A, 120 VAC remote charger power supply in a�ock- Commandock- • HPF-PS10E:240 VAC,50/60 Hz,3.5A maximum able, metal enclosure, black • Wire Size:#12-14 AWG with 600 V insulation HPF-PS6E: 6.0 A,240 VAC remote charger power supply in a Input Circuit: able, metal enclosure, red • Trigger Input Voltage: 9 to 32 VDC HPF-PS10: 10.0 A, 120 VAC remote charger power supply in a • Trigger Current:2.0 mA(16-32 V); Per Input: 1.0 mA(9- 16 V) lockable, metal enclosure, red Trouble Contact Rating: 4 A at 24 VDC HPF-PS10B: 10.0 A, 120 VAC remote charger power supply in a Output Circuits: lockable, metal enclosure, black HPF-PS10E: 10.0 A, 240 VAC remote charger power supply in a • 24 VDC filtered, regulated lockable, metal enclosure, red • HPF-PS6(B): TB8-TB9— 1A Regulated, 3A special applications; ZNAC-PS: Optional Class A output converter module TB10-TB12—0.3A Regulated,3A special applications • HPF-PS1 O(B): TB8-TB11 — 1.5A Regulated, 3A special applica- 50152254-001: Hardware kit for Canadian applications tions;TB12-TB14—0.3A Regulated,3A special applications 17045: Alternate NOTIFIER lock set • 6.0 A (HPF-PS6) or 10.0 A (HPF-PS10) maximum total continu- FCM-1: Addressable Control Module for one Class B or Class A ous current for all outputs zone of supervised, polarized Notification Appliances. Notification Secondary Power(Battery)Charging Circuit: Appliance Circuit option requires external 24 VDC to power notifica- • Supports lead-acid batteries only tion appliances. • Float-charge voltage:27.6 VDC FRM-1: Addressable relay module containing two isolated sets of • Maximum current charge: 1.5 A Form-C contacts,which operate as a DPDT switch • Maximum battery capacity: 18 AH (inside cabinet) FMM-1:Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end- • Maximum battery charging capacity:33 AH (external cabinet) of-line resistor. Module may be configured for either a Class B or Physical: Class A IDC. • Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.8H x 36.83W x FDM-1: Dual Monitor Module. Same as FMM-1 except it provides 8.9D) two inputs for Class B wiring only • Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two FDRM-1: Provides two monitored inputs and two Form-C relays. 18 AH batteries is 39 pounds(17.7 kg) Functions in Class B wiring only. XP6-C: Six-circuit supervised control module XP6-R: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required, see BAT Series data sheet DN-6933). BAT-12180-BP: Battery, 12 volt, 18AH,2-pack BAT-12330: Battery, 12 volt,33AH SEISKIT-MULTI-1: Seismic kit for the HPF-PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. I® 9Y11M9IIN1 a mmem oNs QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIERO and System Sensor(D are registered trademarks of Honeywell International,Inc.Wheelock®is a registered trademark of Cooper Tech- nologies Company.Gentex0 is a registered trademark of Gentex Corpora- tion. AMSECO®is a registered trademark of Potter Electric Signal 12 Clintonville Road Company,LLC.ANSI®is a registered trademark of the American National Northford,CT 06472 Standards Institute,Inc. NOT 1 F 1 E R 203.484.7161 02023 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. by Honeywell www.notifier.com Country of Origin:USA 0 S� �G ;40V FD FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this DOCUMENTSFIRE ALARM product allows you to do just that. NFPA 72 2010 Records / Programs . section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and Standard Features: documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and • 2 Key ring hooks to hold system keys reference. Inside the cover it has a organized note • Business card holder for key contacts Overall Dimensions are 12" x 13" tall and table that allows for documentation for passwords • 2 '/4 deep and other critical system information. • 16 gauge steel box and cover for security • Durable powercoat baked on finish other colors available • Standard 3/4"cat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 1" high "Fire Alarm Documents" • Legend sheet for passwords and system information ISO 9001 � I rr� REGISTERED , Space Age Electronics, Inc. COMPANY ADA www.Isae.com 800.486.1723 Toll Free NFP� Made In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 No Excuses, ED0447 LT10505 Rev.B 1/2 ,lust Solutions! rSPACEAGE LECTRONICS, INC. Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure.A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. m amao,a, ,O(ah,o) mox Property Information Minimum Required Documentation(SIG-FUN) Key Ring �p.m N.�o E�e1P �a,'a,`�o® - - - HooksNIA�ppa oEc-0,a,-,- ■ Certifications nrd Ap prroontr „wn o�piwaa o.a..ro an '�o-a'am comma age mam `r 16.1 System Installation Contractor ...aa mgo. a�..� aq�. uoumm mao-i:o.caRaamm,m �� own o�oioaae o.a.ao� Business --- o�a a arlow,. mppap mapm p�m mo Card Holder 6SAathoriyNavingJudadidion: �` Qa- Sare o wn o f �w.o�aaaaa o,ar loaw. �.�w cm�� Ia FPn�m�aam���.aa namm. ae�a,a�a win a o1,11�=,,.,p%1�1aiw1g 1-11 cawnn r.. ,.az NA wnoEc , m, 01 As-- Equipment Information om rascwpi emwina _ - o Ion NIAo ena«ea a,,.row marenca n a anw wi l spewnga Eiectronka.inc. se cvrockaae aoea ste g, wssa sooaesrrss wuw.taea.wm LT10 4 R-1 Legend sheet for storing system information - including contacts,sign-off,maintenance & test information,and alternate locations of additional records. Ordering Information: Part # Description / SS000672 Fire Document Box RED •/ Space Age Electronics, Inc. SS000673 Custom screening with your Logo www.Isae.com 800 4486.1723 Toll Free Check out our Infinity line eFAD single gang 2 Gig digital storage 508.485.0966 Local solutions (IAMEFAD) 508.485.4740 Fax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0447 LT10505 Rev.B 2/2 DF-61010:C sD365 Series Fire•LiTeALarms Addressable Photoelectric Smoke Detectors 8 by Honeywell Addressable Devices The Fire-Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke detectors are designed for both perfor- mance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. � Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary,decimal address switches,provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A)and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features • Plugs into separate base for ease of installation and maintenance SLC LOOP: • Separate base allows interchange of photoelectric, ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring OPTIONS: • Compatible with LiteSpeedTm and CLIP protocol systems • Optional relay,isolator,and sounder bases • Stable communication technique with noise immunity Installation ADDRESSING: SD365 Series plug-in intelligent smoke detectors use a detachable • Addressable by device base to simplify installation, service and maintenance. Installation • Rotary,decimal addressing instructions are shipped with each detector. (Refer to the Fire-Lite panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE: is at least 1.5" (3.81 cm) deep. For a chart of compatible junction • Sleek, low-profile,stylish design boxes, see DF-60059. Unique single source design to respond quickly and dependably NOTE: Because of the inherent supervision provided by the SLC loop, • end-of-line resistors are not required. Wiring 7-taps"or branches are to a broad range of fires permitted for Class`B"wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the 1300(A) installation • Built-in tamper resistant feature sheet 156-3626 for device limitations between isolator modules and isola- tor bases. • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the Construction detector LED: 12-[pause]-1(LiteSpeed systems only) These detectors are constructed of fire-resistant plastic.The SD365 • Built-in functional test switch activated by external magnet Series plug-in intelligent smoke detectors are designed to commer- • Removable cover and insect-resistant screen for simple field cial standards and offer an attractive appearance. cleaning • Expanded color options Operation OPERATION: Each SD365 Series detector uses one of the panel's addresses (total limit is panel dependent)on the Fire•Lite Signaling Line Circuit • Designed to meet UL 268 7th Edition (SLC). It responds to regular polls from the control panel and reports • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- its type and the status. If it receives a test command from the panel old level (or a local magnet test), it stimulates its electronics and reports an • LED "blinks"when the unit is polled (communicating with the fire alarm. It blinks its LEDs when polled and turns the LEDs on when panel)and latches in alarm. commanded by the panel. The SD365 Series offers features and • Low standby current performance that represent the latest in smoke detector technology. MECHANICALS: Detector Sensitivity Test • Sealed against back pressure Each detector can have its sensitivity tested (required per NFPA 72, • SEMS screws for wiring of the separate base Chapter 14 on Inspection, Testing and Maintenance)when installed/ • Designed for direct-surface or electrical-box mounting connected to an Fire-Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DF-61010:C•5/28/2020—Page 1 of 3 Product Line Information B200SA-WH:Same as B200S-WH, ULC listing NOTE:"-IV"suffix indicates CLIP and LiteSpeed device. B200SA-IV: Same as B200S-IV, ULC listing NOTE:`A"suffix indicates Canadian version. B200SCOA-WH: White, Intelligent, programmable sounder base in SD365:White,low-profile intelligent photoelectric sensor, LiteSpeed Segls French es detector (required in Canada for ULC applications with CO only SD365A: Same as SD365 but with ULC listing B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO SD365-IV: Ivory, low-profile intelligent photoelectric sensor Series detector applications, ULC listing SD365A-IV: Same as SD365-IV but with ULC listing B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- SD365T:White,same as SD365 but includes a built-in 135°F(57°C) 10% with a square wave or its equivalent; designed to meet the fixed-temperature thermal device, LiteSpeed only NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) SD365TA:Same as SD365T but with ULC listing B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F sounder base. Produces a fundamental frequency of 520 Hz +/- (57°C)fixed-temperature thermal device 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) SD365TA-IV: Same as SD365T-IV but with ULC listing B200SR-WH: White, Intelligent sounder base capable of producing SD365R: White, low-profile intelligent photoelectric sensor, remote sound output with ANSI Temporal 3 or continuous tone. Intended for test capable,for use with DNR/DNRW, LiteSpeed only retrofit applications. (CSFM: 7300-1653:0213) SD365RA: Same as SD365R but with ULC listing, for use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA sound output with ANSI Temporal 3 or continuous tone. Intended for SD365R-IV: Ivory,low-profile intelligent photoelectric sensor,remote retrofit applications. (CSFM: 7300-1653:0213) test capable,for use with DNR/DNRW B200SRA-WH: Same as B200SR-WH with, ULC listing SD365RA-IV:Same as SD365R-IV but with ULC listing,for use with B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing DNRA B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NOTE:For details on intelligent bases,see DF-60059. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-6:White, 6"base,standard flanged low-profile mounting base tions. (CSFM: 7300-1653:0238) (CSFM:7300-1653:0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base (CSFM:7300-1653:0109) 10% with a square wave or its equivalent; designed to meet the B300A-6: Same as B300-6, ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B30OA-6-IV: Ivory, 6" standard flanged low-profile mounting base,ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6,package contains 10 TR300:White, replacement flange for B210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A)base base. UL/ULC listed (CSFM: 7300-1653:0109) RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box. For use with B501(A)and B300-6(A). UL/ULC listed (CSFM:7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00:Test magnet with telescoping handle base. UL/ULC listed (CSFM: 7300-1653:0109) CK300: Color Kit(includes cover and trim ring),white, 10-pack B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 CK300-IV: Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-WH:White, relay base(CSFM: 7300-1653:0216) CK300-BL: Color Kit(includes cover and trim ring), black, 10-pack B224RB-IV: Ivory, relay base(CSFM:7300-1653:0216) B224RBA-WH:White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B20OS-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses LiteSpeed protocol. (CSFM:7300-1653:0213) B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) Page 2 of 3—DF-61010:C•5/28/2020 SYSTEM SPECIFICATIONS Sensitivity: Listings and Approvals • UL Applications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the SD365 Series detectors. • ULC Applications:0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0" (51 mm) high; base determines diameter approval agencies, or listing may be in process. Consult factory for —B300-6:6.1" (15.6 cm)diameter latest listing status. —B501:4" (10.2 cm)diameter • UL/ULC Listing: S1059 For a complete list of detector bases see DF-60983 • FM Approved • CSFM:7272-0075:0502 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SD365:32°F to 122°F(0°C to 50°C) • SD365T Series: 32°F to 100°F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20oC to 70oC) UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135OF(57°C), rate-of- rise detection 15°F(8.3°C)per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(o ne communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS Fire-Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. LiteSpeedTM is a trademark, and Fire•LiteO Alarms and System Sensor® are registered trademarks of Honeywell International Inc. 02020 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING&MANUFACTURING QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61010:C•5/28/2020 DF-52013:C1 •E-100 BG.12Lx FIM-LITe ALarms Addressable Manual Pull Station by Honeywell Addressable Devices General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for . Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features PUSH IN • Maintenance personnel can open station for inspection and IPULLDOWNI address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4" (10.16 cm)square electrical box. • Smooth dual-action design. N a' • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTT- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Weight: 9.6 oz. (272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC loop current:230 NA. Specifications • Temperature Range:32°F to 120°F(0°C to 49°C) Manual Fire Alarm Stations shall be non-coded, with a key- • Relative Humidity: 10%to 93%(noncondensing) operated reset lock in order that they may be tested, and so • For use indoors in a dry location designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- tion shall automatically condition itself so as to be visually Installation detected as activated. Manual stations shall be constructed of The BG-12LX will mount semi-flush into a single-gang,double- red-colored polycarbonate material with clearly visible operat- gang,or standard 4" (10.16 cm)square electrical outlet box,or ing instructions provided on the cover. The word FIRE shall will surface mount to the model SB-10 or SB-1/0 surface back- appear on the front of the stations in white letters, 1.00 inches box. If the BG-12LX is being semi-flush mounted, then the (2.54 cm) or larger. Stations shall be suitable for surface optional trim ring (BG12TR) may be used. The BG12TR is mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within DF-52013:C1 •8/16/10—Page 1 of 2 the limits defined by the Americans with Disabilities Act(ADA) Agency Listings and Approvals or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. In some cases,certain modules or applications may not be listed by certain approval agencies,or listing may be in pro- Manual stations shall connect with two wires to one of the con- cess.Consult factory for latest listing status. trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the UL Listed:S711 state of the manual switch. Manual stations shall provide • MEA:67-02-E address setting by use of rotary decimal switches. • CSFM: 7150-0075:0184 • FDNY: Product Line Information • FM Approved BG-12LX: Dual-action addressable pull station. Includes key Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; locking feature. 6,632,108. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Flre•Llte is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:C1•8/16/10 DF-52121:E•E-325 MMF-300(A) Series, Fire•�iTe�ALarms MDF-300 Addressable Monitor Modules by Honeywell Addressable Devices General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices,such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors • ®5E •ary= E.. (MMF-302(A)). MMF-300(A)is a standard-sized module(typically mounts to a s 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. ••oA,.,N ._�,... ..,..,_• MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 aa, cm) H x 2.75" (6.985 cm)W x 0.65" (1.651 cm) D that super- vises a Style B(Class B)circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. o MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B (Class B)or Style D (Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided)terminates the Style B circuit. No resistor is required Fire-Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. power required. Maximum current draw: 5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 375 pA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels,01 —99 on other compatible systems. • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range: 32°F to 120°F(0°C to 49°C). gent, two-wire systems, where the individual address of each Humidity range: 10%to 93%noncondensing. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit (IDC) for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-301(A) Mini Monitor Module MMF-300(A)APPLicAmNs Built-in type identification automatically identifies this device Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally- Powered directly by two-wire SLC loop. No additional open dry-contact alarm activation devices. May also be used power required. to monitor normally-open supervisory devices with special High noise(EMF/RFI)immunity. DF-52121:E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring. Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on MS-9600 series source. panels, 01 —99 on other compatible systems High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 AD 1 Direct-dial entry entry of address: 01 — 159 on MS-9600 13 2 2 series panels,01 —99 on other compatible systems. 11 0 4 LOOP O 3 LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. 10 9 $ 7 6 Ll 5 9 $ 7 6 5 TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status `s (normal, open, or alarm) of one full zone of conventional UJ flu Q detectors back to the control panel. All two-wire detectors 0 m being monitored must be UL compatible with the module.The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS L Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B (Class B)or Style D (Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A) OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC). A flashing LED detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices. May also be used panel. The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop). supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device MMF-302(A) SPECIFICATIONS Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit. Maximum current draw: 5.1 mA(LED on). MMF-301(A) OPERATION Maximum IDC wiring resistance: 25 Ohms. Each MMF-301(A) uses one of the available module Average operating current: 270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds, 3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance: 3.9K Ohms. MMF-301(A) SPECIFICATIONS External supply voltage(between Terminals T10 and T11): Nominal operating voltage: 15 to 32 VDC. • DC voltage:24 volts power limited. Average operating current: 350 pA, 1 communication every Ripple voltage:0.1 Vrms maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Current:90 mA per module maximum. Shorted). Temperature range: 32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:450 NA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance:47K Ohms. Temperature range: 32'F to 120'F(0°C to 49'C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire Wire length: 6"(15.24 cm)minimum. alarm and supervisory devices. The module has a single panel- controlled LED. MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. Page 2 of 4—DF-52121:E•07/30/2015 NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- MDF-300(A): Monitor module, dual, two independent Class B cuits ONLY. Style D (Class A) IDC circuits are NOT supported in circuits. any application. SM6500: Optional surface-mount backbox. MDF-300(A) SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring Normal operating voltage range: 15 to 32 VDC. Manual, PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current: 750 pA(LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range: 32'to 120°F(0'to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM: 7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:A"suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module,two-wire detectors. DF-52121:E•07/30/2015—Page 3 of 4 Fire•Lite@ is a registered trademark and LiteSpeedTm and FireWatchTm are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52121:E•07/30/2015 DF-52347:A•E-900 MMF-300-1 O(A) Flre•LITe'ALarms Ten-Input Monitor Module by Honeywell Addressable Devices General The MMF-300-10 ten-input monitor module is an interface m m mm m between a control panel and normally open contact devices 0 ® mm ©m om in intelligent alarm systems such as pull stations, security contacts,or flow switches. The first address on the MMF-300-10 is set from 01 to 150 _ and the remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for dis- abling a maximum of two unused addresses. The supervised state (normal, open, or short) of the moni- tored device is sent back to the panel. A common SLC input is used for all modules,and the initiating device loops share a common supervisory supply and ground — otherwise each monitor operates independently from the others. Each MMF-300-10 module has panel-controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. NOTE: Unless otherwise specified,the term MMF-300-10 is used in this data sheet to refer to both the MMF-300-10 and the MMF- 300-10A(ULC-listed version). Features Mounting options: • Listed to UL Standard 864, 9th edition. —CHS-6 chassis: Up to 6 modules. • Ten addressable Class B or five addressable Class A initi- —BB-6F cabinet: Up to 6 modules. ating device circuits. —BB-2F cabinet: One or two modules. • Removable 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2) Wire gauge: 12 AWG (3.25 mm2)to 18 AWG (0.9 mmz). plug-in terminal blocks. Power-limited circuits must employ type FPL, FPLR, or p Y Yp • Status indicators for each point. FPLP cable as required by Article 760 of the NEC. • Unused addresses may be disabled. MMF-300-10 is shipped in Class B position; remove shunt • Rotary address switches. for Class A operation. • Class A or Class B operation. Maximum SLC wiring resistance: 40 or 50 ohms, panel • Flexible mounting options. dependent. • Mounting hardware included. Maximum IDC wiring resistance: 1500 ohms. Specifications Maximum IDC voltage: 10.2 VDC. Standby current: 3.5 mA (SLC current draw with all Maximum IDC current: 240 µA. addresses used; if some addresses are disabled, the standby current decreases). Alarm current: 55 mA(assumes all ten LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 49°C) for UL applications;—10°C to+55°C for EN54 applications. Humidity: 10% to 85% noncondensing for UL applications; 10%to 93%noncondensing for EN54 applications. Dimensions: 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25" (31.75 mm)deep. Shipping weight: 0.76 lb. (0.345 kg) including packaging. DF-52347:A•05/15/2009—Page 1 of 2 Agency Listings and Approvals The listings and approvals below apply to the MMF-300- 10(A)Ten-Input Monitor Module. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. • UL Listed:S2424 • ULC Listed: S2424 • CSFM approved:7300-0075:205 • FM approved • MEA approved:55-02-E Product Line Information / MMF-300-10:Ten-input monitor module. �/ MMF-300-10A: Same as above with ULC Listing. BB-2F: Optional cabinet for one or two modules. Dill sions, DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm) deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm] including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm); CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312" (18.5725 cm) high interior overall x 2.156" (5.4762 cm)deep overall. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm)wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm)deep. CHS-6: Chassis, mounts up to six modules in BB-6F. FireLite@ Alarms@ and System Sensor@ are registered trademarks of Honeywell International Inc. Microsoft@ and Windows@ are registered trademarks of the Microsoft Corporation. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Made in the U.S.A. www.firelite.com Page 2 of 2—DF-52347:A•05/15/2009 df-60379:A1 •E-400 CRF.300(A) Firelffe Alarms Relay Module by Honeywell Addressable Devices General The CRF-300(A)Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming,on a select basis. �M LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- ""'o Uffin munication between analog intelligent devices. Intelligent .<,,., •�-,* devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The •• �':".•..^� net effect is response speed greater than five times that of other designs. „ Features • Built-in type identification automatically identifies these o devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is CRF-300(A) received from the control panel and turns on in steady red when activated. • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. Specifications • Direct-dial entry of address: 01—159 for MS-9600(A)series Normal operating voltage: 15 to 32 VDC. panels,01 —99 on MS-92000DLS(A)and MS-9050UD(A). Maximum SLC current draw: 6.5 mA(LED on). Applications Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode)with LED flashing. The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. for door holders,Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Temperature range: 32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%non-condensing. Construction Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x • The face plate is made of off-white heat-resistant plastic. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x • Controls include two rotary switches for direct-dial entry of 2.125" (5.398 mm)deep box. address setting. • The CRF-300(A)is configured for a single Class B(Style Y) Relay Contact Ratings or Class A(Style Z)Notification Appliance Circuit. Maximum Current • The CRF-300(A) provides two Form-C dry contacts that Load Description Application Voltage Rating switch together. Resistive Non-Coded 30 VDC 3.0 A Operation Resistive Coded 30 VDC 2.0 A Each CRF-300(A)uses one of the addresses on a SLC loop. It Resistive Non-Coded 110 VDC 0.9 A responds to regular polls from the control panel and reports its Resistive Non-Coded 125 VAC 0.9 A type and status, including the open/normal/short status of its Notification Appliance Circuit(NAC).The LED blinks with each Inductive(L/R=5ms) Coded 30 VDC 0.5 A poll received. On command, it activates its internal relay. Inductive(L/R=2ms) Coded 30 VDC 1.0 A NOTE:Open/short supervision is suspended with the CRF-300. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. df-60379:A1•08/04/09—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424 • ULC: S2424 • FM approved • CSFM: 7300-0075:185 • MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. : Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual,document 51309. LiteSpeedTM is a trademark and Fire-Lite®Alarms is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. S 0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-60379:A1•08/04/09 DF-52121:E•E-325 MMF-300(A) Series, Fire•�iTe�ALarms MDF-300 Addressable Monitor Modules by Honeywell Addressable Devices General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices,such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors • ®5E •ary= E.. (MMF-302(A)). MMF-300(A)is a standard-sized module(typically mounts to a s 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. ••oA,.,N ._�,... ..,..,_• MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 aa, cm) H x 2.75" (6.985 cm)W x 0.65" (1.651 cm) D that super- vises a Style B(Class B)circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. o MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B (Class B)or Style D (Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided)terminates the Style B circuit. No resistor is required Fire-Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. power required. Maximum current draw: 5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 375 pA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels,01 —99 on other compatible systems. • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range: 32°F to 120°F(0°C to 49°C). gent, two-wire systems, where the individual address of each Humidity range: 10%to 93%noncondensing. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit (IDC) for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-301(A) Mini Monitor Module MMF-300(A)APPLicAmNs Built-in type identification automatically identifies this device Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally- Powered directly by two-wire SLC loop. No additional open dry-contact alarm activation devices. May also be used power required. to monitor normally-open supervisory devices with special High noise(EMF/RFI)immunity. DF-52121:E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring. Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on MS-9600 series source. panels, 01 —99 on other compatible systems High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 AD 1 Direct-dial entry entry of address: 01 — 159 on MS-9600 13 2 2 series panels,01 —99 on other compatible systems. 11 0 4 LOOP O 3 LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. 10 9 $ 7 6 Ll 5 9 $ 7 6 5 TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status `s (normal, open, or alarm) of one full zone of conventional UJ flu Q detectors back to the control panel. All two-wire detectors 0 m being monitored must be UL compatible with the module.The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS L Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B (Class B)or Style D (Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A) OPERATION existing systems. Each MMF-302(A) uses one of the available module MMF-301(A)APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC). A flashing LED detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices. May also be used panel. The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop). supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device MMF-302(A) SPECIFICATIONS Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit. Maximum current draw: 5.1 mA(LED on). MMF-301(A) OPERATION Maximum IDC wiring resistance: 25 Ohms. Each MMF-301(A) uses one of the available module Average operating current: 270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds, 3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance: 3.9K Ohms. MMF-301(A) SPECIFICATIONS External supply voltage(between Terminals T10 and T11): Nominal operating voltage: 15 to 32 VDC. • DC voltage:24 volts power limited. Average operating current: 350 pA, 1 communication every Ripple voltage:0.1 Vrms maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Current:90 mA per module maximum. Shorted). Temperature range: 32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:450 NA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance:47K Ohms. Temperature range: 32'F to 120'F(0°C to 49'C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire Wire length: 6"(15.24 cm)minimum. alarm and supervisory devices. The module has a single panel- controlled LED. MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. Page 2 of 4—DF-52121:E•07/30/2015 NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- independent Class B MDF-300 A : Monitor module, dual, two inde ` ( ) N cuits ONLY. Style D (Class A) IDC circuits are NOT supported in circuits. any application. SMB500: Optional surface-mount backbox. MDF-300(A) SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring Normal operating voltage range: 15 to 32 VDC. Manual, PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current: 750 pA(LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range: 32'to 120°F(0'to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM: 7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:A"suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module,two-wire detectors. DF-52121:E•07/30/2015—Page 3 of 4 Fire•Lite@ is a registered trademark and LiteSpeedTm and FireWatchTm are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52121:E•07/30/2015 DTK-HW Series DITEK Parallel Connected Surge Protective Device Surge Protection nITIEK's r)TK-HW SeriF, of surge protective devices are designed and manufactured to meet the standards of the life safety industry. These compact, parallel-mount SPD's are • available for 120V, 240V and 120/240V systems; and are widely used to protect fire alarm panels and other dedicated branch circuit loads. Their small footprint enables installation in a variety of locations. j Product Features Technical Specifications > Approved for 20A circuit breakers Part Number: DTK-120HW DTK-240HW DTK-120/240HW NEMA 4X weatherproof enclosure Single 0 Single 0 Split 0 allows for use in harsh environments Voltage Configuration: (2W +G) (2W +G) (3W +G) Diagnostic LED provides positive 120VAC 240VAC 120/240VAC indication of system power and SPD MCOV: 150V/300V 320V/640V 150V/300V function Complies with ANSI/IEEE C62.41 Voltage Protection 700V L-G, L-N 1200V L-G, L-N 700V L-G, L-N and C62.45 Category B standards Rating: 1500V N-G 2000V N-G 1500V L-L, N-G Surge Current Rating: 50,000A 50,000A 100,000A Applications SCCR: 100,OOOA > Fire Alarm Control Panels Nominal Discharge 10kA Residential Electrical Panels Current Rating (In): Equipment Panels Pumps, Motors, Lift Pump Stations connection Method: ��3/4" NPT Male, 18-inch 12 AWG Leads Housing: r NEMA 4X Polycarbonate Accessories Operating IN -31°F- 176°F(-35°C-80oC) > Flush Mount Kit— DTK-FMK Temperature: Maximum Humidity: 95% non-condensing Dimensions: 3.5" L x 1.89"W x 3.4" H (88.9 mm x 48.3 mm x 86.4 mm) Weight: J■ 0.55 lb (0.25 kg) Pertifications: �UL1449 4th Edition, CSA C22.2 No. 269.1-17 SPD Type: ■IM— Type 1 Warranty: -■ 10 Year Limited Warranty MADE IN C UL US LISTED D, S. A. DITEK Surge Protection, Largo, FL 33771 ♦ Sales: 800-753-2345 ♦ www.diteksurgeprotection.com ♦ SPS-100057-001 Rev 18 01/22 Every precaution has been taken to ensure that this literature is accurate and complete.DITEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. SYSTEM SENSOR° r L-Series and L-Series with LED Indoor Selectable F I I I R 9 Horns, Strobes and E Horn Strobes System Sensor L-Series and L-Series with LED audible r visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter(DVM)diagnostic test points for Horn strobes,and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15,30,75,95, wall or ceiling mount,standard or compact sizes, red or white color 115, 150,and 177 choices, bezel kits for alternate markings and languages,and LED • Rotary switches for candela,tone and volume selections color lenses for distinctive visual signaling. In addition,installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela,tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert,SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify • Synchronization through use of UL approved power supplies that installation.All devices feature plug-in designs with minimal intrusion support System Sensor Sync protocol or System Sensor MDL3 into the back box,making installations fast and foolproof while Sync Module virtually eliminating costly and time-consuming ground faults.The • Horns,Strobes and Horn Strobes listed for wall or ceiling use universal mounting plate includes an onboard shorting spring,so installers can test wiring continuity before the device is installed. In addition,the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without SIGNALING SIGNALING removing the appliance from the wall or ceiling.The DVM test points F M ti are discreetly located on the face of the notification appliance which 60 U5 LISTED LISTED LISTED APPROVED enable faster troubleshooting and end of line(EOL)voltage checks Horn Strobes Horns: Horns; 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: 54011 S4011 FM23FPUS0195 7135-1653:0503 55512,54011 7135-1653:0526 during troubleshooting. AVDS916-01•10/03/2023•Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage,LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage,Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range,LED Strobes and Horn Strobes 16 to 33 V(24 V nominal) Operating Voltage Range,Horns 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UUULC Current Draw Data, Horn Tones, and Sound Output Data UIJULC Maxmimurn Strobe Current Draw(mA) UUULC Maxmimum Horn Current Draw(mA RMS) Candela 16-33 Volts 8-17.5 Volts 16-33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UUULC Maximum Horn Strobe Current Draw(mA)and Sound • .: Current Draw(mA RMS),Horn Strobe, Sound Candela Range(15-185 cd) Output (d BA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01•10/03/2023•Page 2 L-Series with LED Dimensions:Wall-Mounted Equipment 2.07" (63 mm) -� 3.46" 3.46" 1.25' m 88 mm 1.2 3.57" 1 88 mm 32 mm (9.1 cm) (3.9 c cm) (31.8 mm) no °• 00o• 5.38"5.27' o00o Oo00000o0o0op133.9 mm3..27" 3.7 cm)133.9014Y I I lei 2, L�® �� A0617-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls(SBBGRL,SBBGWL) 2.07" 4.7" 1. 4.T' 1 B mm) 119 mm 32 mm (424 ) 1.85" 119 mm 1.25" 14.8" (4.69 cm) 06°0°0°0°0010 a�o LIP 00000•.°oo. •d0°a oo 00000°o°a°o •o a o•4 a 00000 004004 144 5.mm aoo 0 0 5.67' .a.o. r .o.o.o0 5.78" O 1.mm oa0000o0�00 (14.68 CM)00000000000 ° o0000000000 1® ®® A0613-00 A0549-00 A0554-01 Strobes,Horn Strobes Horn Surface Mount Back Box for Walls for Walls(SBBRUSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 2.07" 6.92"diam. 2.5' (52.6 mm) (175.77 mm) (64 mm) 6.83"diam. 1.25" (173.5 mm) (31.8 mm) O O o C= o- O C=) 0 0 0 ® o o Q o 0 o 0 A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings(SBBCRL,SBCWL) AVDS916-01•10/03/2023•Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P21FILED 2-Wire,Horn Strobe,Wall,Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire,Horn Strobe,Wall,Red,Bilingual LENS-133 Lens LED Blue Wall/Ceiling P2WLED 2-Wire,Horn Strobe,Wall,White LENS-133 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire,Horn Strobe,Wall,White,Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire,Compact Horn Strobe,Wall,Red Accessories P2GRLED-B 2-Wire,Compact Horn Strobe,Wall,Red,Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire,Compact Horn Strobe,Wall,White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire,Compact Horn Strobe,Wall,White, SBBWL Wall Surface Mount Back Box,Red Bilingual SBBWL Wall Surface Mount Back Box,White P2RLED-P 2-Wire,Horn Strobe,Wall,Red,Plain SBBGRL Compact Wall Surface Mount Back Box,Red P2WLED-P 2-Wire,Horn Strobe,Wall,White,Plain SBBGWL Compact Wall Surface Mount Back Box,White P2RLED-SP 2-Wire,Horn Strobe,Wall,Red,FUEGO TRC-2 Universal Ceiling Trim Ring,Red P2WLED-SP 2-Wire,Horn Strobe,Wall,White,FUEGO TRC-2W Universal Ceiling Trim Ring,White PC2RLED 2-Wire,Horn Strobe,Ceiling,Red SBBGRL Ceiling Surface Mount Back Box,Red PC2RLED-B 2-Wire,Horn Strobe,Ceiling,Red,Bilingual SBBCWL Ceiling Surface Mount Back Box,White PC2WLED 2-Wire,Horn Strobe,Ceiling,White Bezelst PC2WLED-B 2-Wire,Horn Strobe,Ceiling,White,Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe,Wall,Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe,Wall,Red,Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe,Wall,White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe,Wall,White,Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe,Compact,Wall,Red SGRLED-B Strobe,Compact,Wall,Red,Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe,Compact,Wall,White All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. SGWLED-B Strobe,Compact,Wall,White,Bilingual All-ALERT models have"ALERT'marking on cover. SRLED-P Strobe,Wall,Red,Plain All-B models have"FIRE/FEU"marking on cover for use in Canadian SWLED-P Strobe,Wall,White,Plain applications. SRLED-SP Strobe,Wall,Red,FUEGO Amber lenses are not for use in Canadian applications SWLED-CLR- Strobe,Wall,White,ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe,Wall,White,ALERT,Amber Lens SCRLED Strobe,Ceiling,Red Notes for Bezels: SCRLED-B Strobe,Ceiling,Red,Bilingual tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL SCRLED-P Strobe,Ceiling,White,Plain (ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP SCWLED Strobe,Ceiling,White (FUEGO),-SPE(FUEGO/FIRE). SCWLED-B Strobe,Ceiling,White,Bilingual SCWLED-P Strobe,Ceiling,White,Plain SCWLED-CLR- Strobe,Ceiling,White,ALERT ALERT L-Series Horns HRL* Horn,Red HRLA* Horn,Red,Plain, ULC HWL* Horn,White HWLA* Horn,White,Plain,ULC HGRL* Compact Horn,Red HGRLA* Compact Horn,Red,Plain,ULC HGWL* Compact Horn,White HGWLA* Compact Horn,White,Plain,ULC 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. www.systemsensor.com SYSTEM 3333 Unity Drive, Mississauga,ON L5L 3S6 Canada ©2023 System Sensor. Phone:800 SENSOR2•Fax:905 812-0771 Product specifications subject to change without notice.Visit systemsensorcom SENSOR w or current product information,including the latest version of this data sheet. www.systemsensor.ca AVDS916-01.10/03/2023 SYSTEM SENSOR° r L-Series and L-Series with LED Indoor Selectable F I I I R 9 Horns, Strobes and E Horn Strobes System Sensor L-Series and L-Series with LED audible r visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter(DVM)diagnostic test points for Horn strobes,and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15,30,75,95, wall or ceiling mount,standard or compact sizes, red or white color 115, 150,and 177 choices, bezel kits for alternate markings and languages,and LED • Rotary switches for candela,tone and volume selections color lenses for distinctive visual signaling. In addition,installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela,tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert,SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify • Synchronization through use of UL approved power supplies that installation.All devices feature plug-in designs with minimal intrusion support System Sensor Sync protocol or System Sensor MDL3 into the back box,making installations fast and foolproof while Sync Module virtually eliminating costly and time-consuming ground faults.The • Horns,Strobes and Horn Strobes listed for wall or ceiling use universal mounting plate includes an onboard shorting spring,so installers can test wiring continuity before the device is installed. In addition,the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without SIGNALING SIGNALING removing the appliance from the wall or ceiling.The DVM test points F M ti are discreetly located on the face of the notification appliance which 60 U5 LISTED LISTED LISTED APPROVED enable faster troubleshooting and end of line(EOL)voltage checks Horn Strobes Horns: Horns; 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: 54011 S4011 FM23FPUS0195 7135-1653:0503 55512,54011 7135-1653:0526 during troubleshooting. AVDS916-01•10/03/2023•Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage,LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage,Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range,LED Strobes and Horn Strobes 16 to 33 V(24 V nominal) Operating Voltage Range,Horns 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UUULC Current Draw Data, Horn Tones, and Sound Output Data UIJULC Maxmimurn Strobe Current Draw(mA) UUULC Maxmimum Horn Current Draw(mA RMS) Candela 16-33 Volts 8-17.5 Volts 16-33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UUULC Maximum Horn Strobe Current Draw(mA)and Sound • .: Current Draw(mA RMS),Horn Strobe, Sound Candela Range(15-185 cd) Output (d BA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01•10/03/2023•Page 2 L-Series with LED Dimensions:Wall-Mounted Equipment 2.07" (63 mm) -� 3.46" 3.46" 1.25' m 88 mm 1.2 3.57" 1 88 mm 32 mm (9.1 cm) (3.9 c cm) (31.8 mm) no °• 00o• 5.38"5.27' o00o Oo00000o0o0op133.9 mm3..27" 3.7 cm)133.9014Y I I lei 2, L�® �� A0617-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls(SBBGRL,SBBGWL) 2.07" 4.7" 1. 4.T' 1 B mm) 119 mm 32 mm (424 ) 1.85" 119 mm 1.25" 14.8" (4.69 cm) 06°0°0°0°0010 a�o LIP 00000•.°oo. •d0°a oo 00000°o°a°o •o a o•4 a 00000 004004 144 5.mm aoo 0 0 5.67' .a.o. r .o.o.o0 5.78" O 1.mm oa0000o0�00 (14.68 CM)00000000000 ° o0000000000 1® ®® A0613-00 A0549-00 A0554-01 Strobes,Horn Strobes Horn Surface Mount Back Box for Walls for Walls(SBBRUSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 2.07" 6.92"diam. 2.5' (52.6 mm) (175.77 mm) (64 mm) 6.83"diam. 1.25" (173.5 mm) (31.8 mm) O O o C= o- O C=) 0 0 0 ® o o Q o 0 o 0 A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings(SBBCRL,SBCWL) AVDS916-01•10/03/2023•Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P2RLED 2-Wire,Horn Strobe,Wall,Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire,Horn Strobe,Wall,Red,Bilingual LENS-133 Lens LED Blue Wall/Ceiling P2WLED 2-Wire,Horn Strobe,Wall,White LENS-133 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire,Horn Strobe,Wall,White,Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire,Compact Horn Strobe,Wall,Red Accessories P2GRLED-B 2-Wire,Compact Horn Strobe,Wall,Red,Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire,Compact Horn Strobe,Wall,White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire,Compact Horn Strobe,Wall,White, SBBWL Wall Surface Mount Back Box,Red Bilingual SBBWL Wall Surface Mount Back Box,White P2RLED-P 2-Wire,Horn Strobe,Wall,Red,Plain SBBGRL Compact Wall Surface Mount Back Box,Red P2WLED-P 2-Wire,Horn Strobe,Wall,White,Plain SBBGWL Compact Wall Surface Mount Back Box,White P2RLED-SP 2-Wire,Horn Strobe,Wall,Red,FUEGO TRC-2 Universal Ceiling Trim Ring,Red P2WLED-SP 2-Wire,Horn Strobe,Wall,White,FUEGO TRC-2W Universal Ceiling Trim Ring,White PC2RLED 2-Wire,Horn Strobe,Ceiling,Red SBBGRL Ceiling Surface Mount Back Box,Red PC2RLED-B 2-Wire,Horn Strobe,Ceiling,Red,Bilingual SBBCWL Ceiling Surface Mount Back Box,White PC2WLED 2-Wire,Horn Strobe,Ceiling,White Bezelst PC2WLED-B 2-Wire,Horn Strobe,Ceiling,White,Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe,Wall,Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe,Wall,Red,Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe,Wall,White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe,Wall,White,Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe,Compact,Wall,Red SGRLED-B Strobe,Compact,Wall,Red,Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe,Compact,Wall,White All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. SGWLED-B Strobe,Compact,Wall,White,Bilingual All-ALERT models have"ALERT'marking on cover. SRLED-P Strobe,Wall,Red,Plain All-B models have"FIRE/FEU"marking on cover for use in Canadian SWLED-P Strobe,Wall,White,Plain applications. SRLED-SP Strobe,Wall,Red,FUEGO Amber lenses are not for use in Canadian applications SWLED-CLR- Strobe,Wall,White,ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe,Wall,White,ALERT,Amber Lens SCRLED Strobe,Ceiling,Red Notes for Bezels: SCRLED-B Strobe,Ceiling,Red,Bilingual tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL SCRLED-P Strobe,Ceiling,White,Plain (ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP SCWLED Strobe,Ceiling,White (FUEGO),-SPE(FUEGO/FIRE). SCWLED-B Strobe,Ceiling,White,Bilingual SCWLED-P Strobe,Ceiling,White,Plain SCWLED-CLR- Strobe,Ceiling,White,ALERT ALERT L-Series Horns HRL* Horn,Red HRLA* Horn,Red,Plain, ULC HWL* Horn,White HWLA* Horn,White,Plain,ULC HGRL* Compact Horn,Red HGRLA* Compact Horn,Red,Plain,ULC HGWL* Compact Horn,White HGWLA* Compact Horn,White,Plain,ULC 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. www.systemsensor.com SYSTEM 3333 Unity Drive, Mississauga,ON L5L 3S6 Canada ©2023 System Sensor. Phone:800 SENSOR2•Fax:905 812-0771 Product specifications subject to change without notice.Visit systemsensorcom SENSOR w or current product information,including the latest version of this data sheet. www.systemsensor.ca AVDS916-01.10/03/2023 SYSTEM SENSOR° Outdoor Selectable- Output Horns, Strobes, 0 and Horn Strobes for Wall Applications SpectrAlert*Advance outdoor audible visible products SPECTF'A Bert C E are rich with features that cut installation times and A Q V A N maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, •Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic •Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed devices,SpectrAlert Advance can meet virtually any application •Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. •Field-selectable candela settings:15,15/75,30,75,95,1 10,1 15,135, 150,177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes,and •Automatic selection of 12-or 24-volt operation at 15 and 15/75 horn strobes for wall applications include a variety of features that candela increase application flexibility and simplify installation.First,field- Rotary switch for horn tone and three volume selections selectable settings,including candela,automatic selection of 12-or 24-volt operation,horn tones,and three volume options enable •Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. Rated from—40°F to 151°F •Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes •Plug-in design with minimal intrusion into the back box an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without •Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill OU holes for screw-in mounting.Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED F M MEA 7125-1653:188(outdoor strobes) approved 7II5-,653:,88(homstrobes, knock-outs at the back.Ascrew-in NPT plug with an 0-ring gasket 54011(chimes,horn strobes,horns) APPROVED pp chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01200 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non Temporal High 57 56 69 75 95 NA NA 181 176 Non Temporal Medium 42 50 60 69 110 NA NA 202 195 Non Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(115-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn Strobe Output(dBA) ratings must be reduced in accordance with this table. 8-17.5 16-33 24-Volt Nominal Strobe Output(cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 3ZF 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non Temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non Temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 78 85 85 90 90 97 98 150 1150 9t Coded Low 75 75 81 81 88 85 96 92 177 1177 tSettings 7,8,and 9 are not available on 2-wire horn strobe. 185 1185 AVDS01200 SpectrAlert Advance Diagrams 4.7" 2.5" 5.6" O 0 Wall-Mount Horn Strobes ® ® Wall Plastic Weatherproof Back Box 1P Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic outdoor back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic outdoor back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic outdoor back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic outdoor back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic outdoor back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic outdoor back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120V(includes plastic outdoor back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic outdoor back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic outdoor back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic outdoor back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic outdoor back box) Horns HRKt Horn,Red,Outdoor(includes plastic outdoor back box) Accessories SA-WBB Red Separate Ship,Wall-Mount,Outdoor Back Box,Metal SA-WBBW White Separate Ship,Wall-Mount,Outdoor Back Box,Metal Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. m2cha System Sensor. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subjec[to hangewithout notice.Visit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformAVDS 1200-6/11.test ersionokhis data sheet. AVD501200.6/11•#2813 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT Er 16607 SMOKEY POINT BLVD Permit#:6633 Parcel#:31052800204300 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:NEW FIRE ALARM SYSTEM. Valuation:33191.00 APPLICANT CONTRACTOR SFP-B LTD PTNSP Johnson Controls Security Solutions,LLC/ Johnson Controls Security Solutions,LLC Johnna Lambert PO BOX 5350 7815 S. 180th Street 7815 S 180th St BEND,OR 97708-5350 Kent,WA 98032 Kent,WA 98032 5032014772 503 201 4772 LIC:601636830 EXP:07/31/2026 LIC:JOHNSCS7725H EXP:08/08/2027 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 2 CONST.TYPE: 1B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: _ PERMIT APPROVAL _ The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 2 ail • 09/09/2025 9/91 6 Applicant SiAnature Date Building Official Date - CONDITIONS ■ Adhere to the approved plans.Approved plans shall be onsite for inspection. Call for inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/09/2025 Web Only-Fire System Plan Review $200.00 09/09/2025 Credit Card Service $6.00 09/09/2025 Processing/Technology $25.00 09/09/2025 FRCP/Transmitter-New $200.00 09/09/2025 Fire Plarm System Permit $350.00 Total Due: $781.00 Total Payment: $781.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail o FIRE ALARM NOTES Johnson Controls 1. ALL APPLICABLE CODES SHALL BE OBTAINED PRIOR TO START OF WORK JOHNSON CONTROLS 2. THE SYSTEM SHALL BE LOW VOLTAGE,PROTECTED PREMISES FIRE ALARM/CENTRAL STATION SERVICE,ALARM SIGNALS SHALL BE RECEIVED AT JCI'S CENTRAL GLOBAL CENTER OF EXCELLENCE STATION AT: 142M E EXPOSITION AVE#1A 14200 E.EXPOSITION AVE. AURORA,co eoolz DO AL BERATED OR THE ENVIRONMENT li' � �� �� 1-ena3o-7404 3. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING TO THE REQUIREMENTS OF NFPA72 AND THE MANUFACTURES INSTRUCTIONS. i4. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED.5. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. 6. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 10%.(SEE CALCULATIONS). 7. ALL FIRE ALARM DEVICES ARE TO BE U.L LISTED AND COMPATIBLE. The Lodge Apartments Q 2 E 17 1NE a B. ALL WIRE IS TO BE IN CONDUIT FROM DEVICE BACK BOX TO ABOVE FALSE CEILING OR TO THE BAR JOIST.WIRE MAY RUN EXPOSED HORIZONTALLY,BUT MUST BE Una Beauty GoPainters Alley N 'a - CENTER of Ex ceuENGE NETwoRK 1 lahsr NE Benjamin Moore ®. SUPPORTED PER NFPA 70 REQUIREMENTS. Benjamin �% ©Skagit Regional Health-Smokey Point IDl:lnsulati, 9. ALL WIRE SHALL BE POWER LIMITED,FPLP UNLESS OTHERWISE NOTED. Hobby Lobby Q O Bonefish Grill M°ure Pa�ats Q Distributors Ii ouaaan cull® 10. WIRE ROUTING SHOWN IS DIAGRAMMATICAL AND DOES NOT REPRESENT ACTUAL RUNS.WIRE LAYOUT IS SUBJECT TO CHANGE AS NEEDED BY THE INSTALLING Crumb)-Ma II Amamn Fulfillment KEYPLAN: CONTRACTOR. CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS OR PANELS MAXIMUM SIGNAL LINE CIRCUIT Marysville� Center PAE2 CAPABILITIES. Galbi Burger Walmart Supereeni ®eur9=,skis:, Best BUY 0, and Daaks 11. UNLESS OTHERWISE REQUIRED BY INS ANNUNCIATOR/KEYPADS TO BE MOUNTED-4 5IN ABOVE THE FINISHED FLOOR TO THE TOP OF THE UNIT. LES S C H WA B TIRE CENTER jLakewo.. 12. MANUAL PULL STATIONS SHALL BE INSTALLED WITH THE OPERATIONAL PORTION 42-48 INCHES ABOVE FINISHED FLOOR. Target Qen,Q 0 p'Reiylq Auto Parts irts 13. ALL VISUAL DEVICES SHALL HAVE THE CANDELA SET PER APPROVED PRINTS.CANDELA VALUE NOTED NEAR THE DEVICE ON DRAWINGS. sing14. CEILING MOUNTED NOTIFICATION DEVICES ARE NOTED WITH A"C". o •Les Schwab Tire Center Coster,Wholesale15. DESIGN IS BASED ON:CONTRACT DRAWINGS,ENGINEERED PROVIDED PLANS,SITE SURVEY.ALL EQUIPMENT IN THIS DESIGN SHALL BE INSTALLED PER ITS LISTED eo area Gas Station 1-1,PI NE USE. Public Storage ,e a o� 16. DEVICE LOCATIONS ARE BASED UPON APPLICABLE CODE,MANUFACTURES INSTALLATION INSTRUCTIONS,AND ACCEPTED INSTALLATION PRACTICES.SHOULD ANY (7 8 Vt 16607 SMOKEY POINT BLVD. petso n age= P P o CONTACT INFORMATION: UNKNOWN CONDITION BE DISCOVERED DURING INSTALLATION WHICH CONFLICTS WITH APPLICABLE CODE,IT SHALL BE BROUGHT TO THE ATTENTION JCI IN WRITING PRIOR TO INSTALLATION. ARLINGTON, WA 98223. 17. THE TOTAL SOUND PRESSURE LEVEL PRODUCED BY COMBINING THE AMBIENT SOUND PRESSURE LEVEL WITH ALL AUDIBLE NOTIFICATION APPLIANCES OPERATING SHALL NOT EXCEED 110 DBA AT THE MINIMUM HEARING DISTANCE. Gissber 18. A FIRE ALARM SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 DBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND Twin La 8 Marysville Toyota LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS. CascadeParkB1 'f II Ford G of 'rysvillev SHEET INDEX FDrreste wDodBnaes � _ SHEET DESCRIPTION VICINITY MAP ABBREVIATIONS IN INCHES FA000 COVER SHEET scALL.H s KW KILOWATT FA101 DEVICE PLACEMENT PLAN SYMB DESCRIPTION LVL LEVEL FA201 RISER DIAGRAM R CALCULATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUM FA301 PRODUCT TYPICALS AFG ABOVE FINISHED GRADE MIN MINIMUM AMP AMPERE MNS MASS NOTIFICATION SYSTEM City of Arlington AUX AUXILIARY MTD MOUNTED AWG AMERICAN WIRE GAUGE N4 NEMA4-NON CORROSION-PROOF Building Department Y ENCLOSURE APPROVED BFG BELOW FINISH GRADE N4X NEMA4-CORROSION-PROOF e BLDG BUILDING ENCLOSURE Kevin Olander-01/23/2026 N12 NEMA 12-SEALED ENCLOSURE g C CEILING MOUNTED NAC NOTIFICATION APPLIANCE CIRCUIT CIRC CIRCUIT # NUMBER SCOPE OF WORK No changes authorized unless approved by it PNL PANEL NEW FIRE ALARM SYSTEM. the Building Official V PH PHASE COND CONDUIT THE NEW SYSTEM SHALL INCLUDE: e= ON DOWN PS POWER SUPPLY AN ADDRESSABLE FIRE ALARM CONTROL UNIT. tm DWG DRAWING OTY QUANTITY • AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. z SEC SECONDARY A DOCUMENT BOX IS TO BE INSTALLED BY THE CONTROL UNIT. DEGREE SiIGNAL LINE CIRCUIT • A FIRE ALARM ANNUNCIATOR IS TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. ° A SMOKE DETECTOR 15 TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT ELEC ELECTRICAL TEMP TEMPERATURE THE ELECTRICAL ROOM. EXT EXTERIOR MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN 5'OF EGRESS DOORS. eg TYP TYPICAL • HORN/STROBES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. 8 EX EXISTING DEVICE V VOLTAGE • STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. E EQUIP EQUIPMENT VAC VOLTAGE ALTERNATING CURRENT • A WEATHER-PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE SPRINKLER ROOM. as • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. 5 XP EXPLOSION PROOF W WATTS • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. FIRE ALARM SYMBOLS FA I FIRE ALARM WP I WEATHERPROOF • 120VAC SURGE SUPPRESSORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. _V WIRE GUARD • MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS. QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX FL FLOOR WD WIRELESS DEVICE € FT FEET THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES. W/ WITH 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN GND GROUND v€ THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM&EXISTING DUCT DETECTORS. § THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ALARM CELLULAR COMMUNICATOR. &; ,a THE BUILDING IS FULLY SPRINKLERED. s m 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R c= BEFORE INSTALLATION OF ANY SYSTEM COMPONENT,THE INSTALLATION TECHNICIANS SHALL CONFER AND COORDINATE WITH THE GENERAL CONTRACTOR AND ALL OTHER APPLICABLE TRADES TO ENSURE THE INSTALLATION LOCATION WILL NOT CONFLICT WITH OTHER TRADES. 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN ALL WIRE SHALL BE OPEN-RAN OR CONCEALED IN THE WALLS OR CEILINGS.WHERE THE WIRE IS BELOW 10',IT SHALL BE INSTALLED IN Y"EMT CONDUIT. 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN 4E - UPON AHJ'S ACCEPTANCE OF THE NEW SYSTEM,THE EXISTING SYSTEM SHALL BE REMOVED. Y "€ 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D Eaz 7 FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG ISSUE LOG: �^ 6 AIM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D gE fr§ FIRE ALARM MATRIX/SEQUENCE OF OPERATION 2 AIM D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D x SYSTEM OUTPUTS e 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQ x 2.5"D Z o z s i o 0 8 \4 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 2.5"D - - o s� CODE ANALYSIS w Z O B BUILDING OCCUPANCY TYPE M,B,5.1 o w u 0 4 �o HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQ x 2.5"D z C a� NUMBER OF STORIES TWO(2) 0 i o Ca Z e$ PROJECT AREA 16 404 SQ.FF. ¢ o ' o 0 5 10 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D s YG r O > z w ca TYPE OF SYSTEM ADDRESSABLE INITIATION&CONVENTIONAL NOTIFICATION w z z F ac z LISTING AGENCIES(UL,FM,MEA,ULC) UL 864 o w m o w o ¢ G°1 ° 1 HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED WIRING TYPES OPEN CEILING,CONDUIT w 1 r0 �' w Z w J Z Z WP w a a z _ Z _ z - _ z w w TYPE OF COMMUNICATION REMOTE STATION ¢ o z i i ° i a i o ti a m a 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN AUDIBLE NOTIFICATION TEMPORAL 3 w w ❑ ❑ O ¢ a a c qa Z qa z •1 ❑ w Z 3 LES SCNWAB E8 VISUAL NOTIFICATION PUBLIC MODE O ran I m O o o c 2 y ❑ i Oo a w z m ac a re z o! z a z z z w ❑ o Z z 2 �5 SMOKE DETECTOR-DUCT EXISTING BUILDING SPRINKLER SYSTEM FULLY SPRINKLERED O ❑ H w z Z O O_ z O O_ O O o O O_ H ¢ 0 ¢ i ❑ r r O r F o r ul O w❑ o Z Z fir U) ❑ ¢ ¢ N ¢ ¢ j ¢ > W w ul FE STANDARDS NFPA 72(2019),NFPA 70(2017) O ❑ w w ❑ O r ❑ O r g r r 'w H F LES SCHWAB TIRE CENTER @= z ¢ f Z to 'i Z to R' Z ul ra Z w Z m O w Z -s APPLICABLE CODES IBC 2018,IFC 2018,IMC 2018 ASME/ANSI A717.1 2017 w p o re ❑ ❑ O ❑ O i ❑ O 0 > O F ❑ E O H ❑ 2 ® REMOTE ALARM INDICATING AND TEST SWITCH EXISTING ( 1 ( 1 ( ) ( I 3 O O r o H w g z z g z z z z o z z z w w z o O RTS W. O O 3 O `a W W O W W O N ual O N W tz w - w LL K 2 Z > Z Z Z Z N H U ¢ tZ z z > a w w a w a s 0o a 0o Z a 0o 0 , I La 0 La w 1 KB KNOX BOX EXISTING w � Z O F iL f w f w f w ti z I U ti ti D: O O O O U O U O U O U O w U U O U U 16607 SMOKEY POINT BLVD. SYSTEM INPUTS 0 ❑ Z w > o a ¢ m r a m ram ram I- ¢ ¢ r? ¢ w ¢ ¢ 2 FLOW DETECTOR/SWITCH EXISTING ARLINGTON,WA 98223. CONTROL UNIT FUNCTIONS "ALL SYSTEMS NORMAL" X B SYSTEMSILENCE i X I X DESIGNED BY: P.ROJAS a& SYSTEM RESET ONE POINT FOR RESET I I x I I x 1 HP HIGH AIR PRESSURE SWITCH EXISTING DRAWN BY: P.ROJAS s`a DRAWING ACCEPTANCE ALARM DEVICES CHECKED BY: 04/25/2025 s WANUAL PULL STATIONS ES X X X X X 52 THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JON CON CONTROLS EQUIPMENT AND IS NOT TO MANUAL PULL STATIONS X X X X X 1 LP LOW AIR PRESSURE SWITCH EXISTING JOB CASE#: 1-91ZJWV1 BE USED FOR ANY OTHER PURPOSES.IT IS THE RESPONSIBILITY OF THE LOCAL CE WITH CONTROLS SALES 6 SERVICE OFFICE(SS0) SMOKE DETECTORS X X X X X TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. SUPERVISORY DEVICES RECORD DRAWINGS SPRINKLERTAMPER SWITCHES X X X 11 VALVE-GENERAL EXISTING ➢$ D AIR PRESSURE SWITCHES X X X SHOP RAWINGS ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JOHNSON KNOX BOX TAMPER SWITCH X X X p q A� CONTROLS OFFICE AT THE ADDRESS LISTED ABOVE. DUCT SMOKE DETECTORS X X X X V 1 1 y SIAMESE FIRE DEPARTMENT CONNECTION EXISTING SHEET: MONITORING LOCATIONS TROUBLE FUNCTIONS LOSS OF DIAL TONE OR CELL DIALER CONECTION X X X `-; JOHNSON CONTROLS ALARM SERVICE CO:544525 FIRE ALARM SYSTEM AC POWER FAILURE X X X 1420D EXPOSITION AVE. ILL LISTING:S994-183 AURORA,CO.80012 FIRE ALARM SYSTEM LOW BATTERY X X x COVER SHEET 1-8Do-428-7124 ABNORMAL CIRCUIT OR DEVICE X X X �e 3 ORDER OF OPERATIONS DE VICE EVICE LEGEND L s$ o� FA000 �a . I •I. I •I 30"X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1181202,5 1:36:41 PM LAST SAVED BY:JARAIZM FILE PATH:C:\Users\jarai—WireDrive-Johnson ContmLs\Desktop\hhh\LSTC_ArLington_WA_FA_DD01_1-91 ZJWV11-REWORKED.di o o FIRE ALARM SYMBOLS Johnson QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBO% Controls u 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20DX OWN JOHNSON CONTROLS GLOBAL CENTER OF EXCELLENCE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN 142M E EXPOSITION AVE#1A AURORA,CO 80012 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R 1-877-330-7404 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN �✓ 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SSUOD672 OWN 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D CENTER OF ExCELLENCE NERNORK 7 ❑F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG 6 aM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D KEYPLAN: �M20 FIRES 2 aMD DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx2.5"D M79 IIM18 PUMP I 1 aM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D M17 I �M76 M15 i z aM10 '^ I B M STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQx 2.5"D M14 MOS 1 I I¢ MI AIMFS�, ¢ 30 ¢ I 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4-SIX 2.111 M72 C �DQ M71 5 �o HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D 4AFAA I AIM M1AO AIM AIM AIMMO51 CONTACT INFORMATION: A 9 07 M 6/ 1 WPICJ� HORN/STROBE-WALL MOUNT-WEATHERPROOF1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN AA F M / F AAC/ 2 S SMOKE DETECTOR-DUCT EXISTING 95 CD ¢ S RINKLER ROOM TO FACU 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING CEILING OVER 75 CD SHOWROOM IS JB BELOW ¢ o C TO FACU D02 ¢ 1 KB KNO%BOX EXISTING OOM S OOM p TO P FACU LL 2 FLOW DETECTOR/SWITCH EXISTING DO S 1 ALIGMENT BAYS M03 DO u ¢ PARTS ¢ 1 F HP y HIGH AIR PRESSURE SWITCH EXISTING n AIM S I RTU aM LL ^ - OFFICE L-- D_—RT_�" 3 i RTS ®M01 SHOWROOM CB C8 C8 C8 CB AM i I - \75 CD 1 LP LOW AIR PRESSURE SWITCH EXISTING a M02 ¢ o `-'_ ALIGMENT FIT a 11 DQ VALVE-GENERAL EXISTING SS OFF CE g a STORAGE RM. 1 Y, IRS SIAMESE FIRE DEPARTMENT CONNECTION EXISTING e I �C9C9 C9C9� TA �30 CD a> s 2� E� HALL ¢ ¢ PARTS ROOM TO FACU ^ n � � I GENERAL NOTE 1)ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. g REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. TO MAIN I FROM 2N a 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT €o F M04 LEVEL LEVEL I LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS. e 95 CD I 115 CD 3)DEVCE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD g @ a ° a VERIFIED. C TO FACU M27 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 Ea 30 CD (NATIONAL ELECTRIC CODE). 5 ¢ ¢ F 5)WHERE CONDUIT IS REQUIRED,MINIMUM SIZE SHALL BE 3/4-. a 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE PATH. d c WAREHOUSE 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE 150 CD € a HALL V C9 u a ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. v€ C WAREHOUSE UNLOADING I CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO SALES AREA n DIAGONAL RUNS ARE PERMITTED. c I I 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. i8 a a s 8 a Ll>JC\D 5 CD 95CD LOCKERRM. FLAG NOTES NEW FIRE ALARM CONTROL UNIT SHALL BE CONNECTED TO DEDICATED 120 VACPOWER.LABEL CKT BREAKER"FIRE ALARM. 15 O STATION FIRE VIAL OLEROL ATHNIT SHALL COMMUNICATE TO CELLULAR COMMUNATION.MONITORING MONITOR MODULE FOR FIRE ALARM CELL DIALER COMMUNICATOR TROUBLE 15SUPERVISION. 5MEN MONITOR MODULE FOR NAC POWER SUPPLY TROUBLE SUPERVISION. DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF WATERFLOW ISSUE LOG: SWITCH.- (D INSTALL EXTERIOR HORN STROBE NEXT TO THE SPRINKLER ROOM. g E ¢ EOL SCRIPTION 75 CD ®i 10 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVES. fr§ 115 CD EOL C9 F g ¢ C C7 C7 C7 M23 ®8 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVE. e ¢ MONITOR MODULE INSTALLED FOR SUPERVISION OF FIRE PUMP. F F DUAL MONITOR SALES AREA 5 ¢ SERVICE BAYS 10 MODULE INSTALLED FOR SUPERVISION OF HI/LOW AIR PRESSURE SWIT HAT THE DRY SY SYSTEM RISER. b;= 2 N D LEVEL CLOUNGER ¢ 11 FIEELNITOR D MODULE OCAT ONSUPERVISION OF EXISTING DUCT DETECTORS. g� a EN ^B YGLi ¢ A gg FROM 75 CO ¢ 5 FACU C7- ` AD -x M22 F FAA AAA AA -, AAAAAAAAJ KB p WIRE CHART ®LES SCHWAB; MAIN LEVEL CIRCUIT MINIMUMSIZE< SYMBOL CIRCUIT DESCRIPTION TYPE AND TYPE OF WIRE g A SIGNALING LINE CIRCUIT A SLC (pOWERLIMITED) 2-#18AWG LES SCHWAB TIRE CENTER s - City of Arlington ANNUNCIATOR DATA BUS AD ANN (BLK/RD=DATA) 4-#18AWG Building Department (WHT/GRN=PWR) APPROVED C TRIP NOTIFICATION APPLIANCE TRIP CKT. 2#14AWG `R (COMBINED HORN B VISUAL CIRCUIT) 16607 SMOKEY POINT BLVD. Kevin Olander-01/23/2026 INITIATING DEVICE CIRCUIT D IDC (NON-INTELLIGENT DEVICES) 2-#18AWG ARUNcioN,WA 98223. = No changes authorized unless approved by P POWER 24V NON-RESETTABLE POWER 2-#14AWG �^ DESIGNED BY: P.ROJAS a� the Building Official RT TEST REMOTE TEST STATION TEST 4-#18AWG DRAWN BY: P.ROJAS 5CHECKED BY: N/25/2025 e� SH=SHIELDED "WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED JOB/CASE u: 1-91ZJWV1 SHOP DRAWINGS AIR e SHEET: 5E DEVICE PLACEMENT PLAN �e A�1 DEVICE PLACEMENT PLAN o s s$x N SCALE 1 8=1.8' N FEET) O � 6 rAA o� �a • 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:46 PM LAST SAVED BY:JAAIZM FILE PATH:CAUsers\jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_ArLington_WA_FA_DD01_1.91 ZJWV1-REWORKED.dwg o FACP BATTERY CALCULATIONS Alarm i Tptal Total CIRCUIT LOAD&VOLTAGE DROP CALCULATIONS Johnson Dry Part# DescriPllon Standby Alarm stlntleY 0 1 ES-200X Fire NarmParel 0.14100 0.25700 0.1410 0.00 Source: NAC#1 Controls 1 PWR 1324 Optional 24.1t 3 Amp Tmmformer(imkle the"" 0.00700 DOD800 0.0070 0.0080 Circuit Number' 1 IPOTSCOM POTS-ormanicaror(inside the panel) 0.woo 0.04100 awo awo Device DeacrI tlon Standby Alarm C5 C6 C7 C8 C9 JOHNSON CONTROLS 1 AN Remote Pnnunciator 0.0150D 0.woo 0,0150 0.040D wit2 SD365 Ph-electdo Smoke Detector 0.00020 DOMED ODOM 0.0090 WALL MOUNT STROBE RED(15 cd) 000000 0.01800 1 0018 2 0036 0 0 0 0 0 0 GLOBAL CENTER OF EXCELLENCE 7 BG12LX M ll-I Pull Station 0.00038 0.00500 DOOM DOWD ALL MOUNT STROBE RED(30 cd) 0.00000 0.02200 0 0 0 0 0 0 0 0 3 0.066 FIRE ALARM SYMBOLS 142M E EXPOSITION AVE MIA 8 MvF3 odule 00 Wnitor Mh LED(Full S¢e) 0.00038 0.00500 0.0030 0.0400 WA L MOUNT STROBE RED(75 cd) 000000 007000 0 0 0 0 1 007 1 007 0 0 AURORA,CO 8W12 2 MDF300 Dual Mbnitor Mbdule 0.00075 0.00640 0,0015 0.0128 I OEILING MOUNT HORN STROBE RED(75 cd) 000000 0.08700 0 0 0 0 1 0.087 0 0 0 0 QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX 1 MhF3oP10 Ten-Input Monitor Mlotlule 000035 0.00550 o.olxl4 0.0055 I CEILING MOUNT HORN STROBE RED If 15 cd) 0.00000 0.12000 0 0 0 0 2 0.24 0 0 0 0 1-87]-330-7404 1 FL-PS10 NAC BD.-Power Supply(Trgger Current) acoolo0 0.=w 0.0000 0.0020 SPARE SPARE CEILING MOUNT HORN STROBE RED(1 d)cd) 000000 0.08700 0 0 0 0 0 0 0 0 1 0.087 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN 0.2529 0.5603 ALL MOUNT HORN STROBE RED(75 cd) 000000 0.08700 0 0 0 0 0 0 0 0 1 0.087 �L, WALL MOUNT HORN STROBE RED(95 cd) 0.00000 0.09200 2 0.184 0 0 0 0 1 0.092 0 0 r��` Standby Current Total Hours- 0.2529 X 24 = 6.0690 ��, Ours) ALL MOUNT HORN STROBE RED(135 cd) 000000 alesoo 0 0 0 0 0 0 0 0 1 a18s 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ���''� Alarm Current Total Ml= 0.5603 X.083 - o.ows WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 0 0 1 0.212 0 0 0 0 0 0 (S Mns) #Devices 3 0202 3 0248 4 0.397 2 0.162 6 0531 0 0ED0 ITotal 6.1155 Ciruh Amps 0202 0248 0397 0162 G.531 0000 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R CELLENCE NEIVIORK 20 Badery safety rM6 - 1 z231 Cil Length(ft) 80 200 300 270 300 180 Total Voltage Drop(14awg) 0.10 0.32 0.76 0.28 1.02 0.00 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN Total ANRates Baneries Needed = 7.3386 Total EDE Volta a 14 aw 20.30 20.08 19.64 20.12 19.38 20.40 Total AN Rated Batteries Supplied F 12 NOTE: VOLTAGE FORMULA USED IS: 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN KE P AN: NAC#1 BATTERY CALCULATIONS Total VD=LENGTH(CIRCUIT MEASURED ONE-WAY IN FT.)X LOAD(IN AMPERES)X RESISTANCE(.00316 FOR 14AWG)X 2(FOR RETURN RESISTANCE) Total Dty Part# Description snnaby warm snnany warm 2 OP SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D 4 SRLED WALLMOUNTSTROBE RED(15od) 0.00000 0.01800 0.0000 0.07zo WIRE RESISTANCE VALUES REFERENCED FROM NEC TABLE 8 2 SRLED WALLMOUNTSTROBE RED(30cd) 0.000DO 0.0220D 00000 0.0440 2 SRLED WALL MOUNT STROBE RED(75 od) 0.00000 0.07WO 0.0000 0.1400 7 �F FIRE ALARM PULLSTATION FIRELITE BG-12LX IGANG 1 PC2RLED CEILING MOUNT HORN STROBE RED(75 pd) 0.00000 0.08700 O.ODDO 00870 TG-7FS-V BATTERY CALCULATIONS 2 PC2RLED CEILING MOUNT HORN STROBE RED n 15 cd) 0.00000 0.12WO 0.0000 0.2400 1 PC2RLED CEILING MOUNT HORN STROBE RED nED cd) 0.00000 Dial 0.0000 0.1890 Total Total 6 AIM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D 1 P2RLED WALL MOUNT HORN STROBE RED(75 cd) 0.00000 0.08700 00000 0.0870 Qty Part# Description Stantlby Alarm Stand by Alarm 3 P2RLED WALL MOUNT HORN STROBE RED(95 cd) 0.00000 0.09200 0.0000 0.2760 1 TG7FS-V Cell Dialer Communicator 0.08300 023000 0.0830 02300 1 P2RLED WALL MOUNT HORN STROBE RED(135cd) 0.00000 0.18900 0.0000 0.1890 0.0830 02300 2 AIM DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D 1 P2R WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 0.0000 0.2120 D 0 00001 1.5360 Standby Current Total Hours= 0G83G X 24 = 1.9920 CONTACT INFORMATION: Standby Cx°erd T-1 Fbx,s= o000o x. = 0OWD (Hours) 1 AIM 70 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D (Hours) Alarm Current Total Minutes= 02300 X G83 - 0.0191 Alarm Current Total Minutes= 1 53Go x 0a3 = o 1275 (5 Mins) / (5 Mns) Total = 2.0111 8 ,4. STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQx 2.5"D Tutal = 0.1275 20%B,sery Safety M agin - 0.0255 20%Battery Safety Margin = 0.4022 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQx 2.5"D C Total AN Rated Batteries Needed = D.153D Total AH Rated Batteries Needed = 2.4133 5 � HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D Total AH Rated Baaeries Supplied F 7 Total AH Rated Batteries Supplied 7 1 WP�'O HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED A' CALCULATIONS CALCULATIONS 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN 2 'S SMOKE DETECTOR-DUCT EXISTING 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING 95 CD 95 CD 15CD CIR5 EOL 14AWG Ra 1 KB KNOX BOX EXISTING % 2 COND FPLP QQ CIR6 110 CD 2 r V FLOW DETECTOR/SWITCH EXISTING rt $S EOL 14AWG s 2 COND xe 1 HP HIGH AIR PRESSURE SWITCH EXISTING FPLP 9a y CIR7 75 CD 115 CD 115 CD 75 CD EOL 1 LP LOW AIR PRESSURE SWITCH EXISTING N= 14AWG C C C RE c z CONE, == FPLP 11 VALVE-GENERAL EXISTING % 95 CD CIRB 75 CD _ 14AWG ARE 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING E 2 COND FPLP E E 135 CD 75 CD 150 CD E.m CIR9 30 CD \130 CID � _30 CD � EDE Y$ 14AWG C r�RE 2 COND FPLP %C CIR10 ar CO14A D SPARE FIRE PUMP 2 2 CONE, C_RTU 1_�_ F FPLP DOI Moi M02 I M03 M04 DOz MOS Mae .7 stuooP A F s GENERAL NOTE v8 CIR11 EOL SPARE 18 AWG/2 CONE,,FPLP P I ant D I P RavERaul M DD14A 11 ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. E; 2CO D a I P- PowTR MOH Aw9 REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. _= 2COND NO CHANGES TO FACU EXISTING NOTIFICATION APPLIANCE CIRCUITS I S EOL s m cs c6 o ca c9 ClD C10 �� I RT I s x s x n 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT S= T xl IN 0 IC to AP E5 Cl I I LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP RTS �EDLio uEEOLo w E0� EOLy EOL CALCULATIONS. D N M FY IR IT. q 0 G L___J 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD VERIFIED. 5= 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 _- NAC#1 IN ELECTRIC CODE). ° FL-PSio M23 M22 M21 M10 5)WHERE CONDUIT IS REQUIRED,MINIMUM SIZE SHALL BE 3/4". E sT IF AT N L c F F F ant aN 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE 0 T DI C U 4 A G D PATH. Y z N EOL 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE BATTERY BATTERY EOL FP ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. i" 12V 7AH iZV 7AH Re D D D D D D D D D D CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO M:o� Mid M,� MtT NrsI MtI MINI NnI Mtx� Mt� DIAGONAL RUNS ARE PERMITTED. 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. keg DEDICATED 120 VAC 0 IS NG on'IC 0 P EOL EOL EOL EOL EOL EOL EOL EOL EOL EOL 20 AMP CIRCUIT(LOCKED) D 0 0 FY R T. A ISSUE LOG: (BY OTHERS) 2 N -E Na DESCRIP'n N FP M26 M27 M28 INDI 0-PRO PRO-D LAYOUT ;W5 F F AIM D CI ;M24 DE TI N IF AT LI C 0 T DI CI UI 4 G F% 2 0 FP e WIRE CHART C C C3 C4 A SYMBOL CIRCUIT CIRCUIT DESCRIPTION >MINIMUM SIZE< 9 TYPE AND TYPE OF WIRE - - w= is Awc ^^ A SLC SIGNALING LINE CIRCUIT 2.#18AWG 4 COND /�/ (POWER LIMITED) FIRE LITE FPLP `\�()�� ANNUNCIATOR DATA BUS ES-20OX \ TG-7FS-V BASIC SYSTEM FUNCTIONAL AD ANN (BLK/RD=DATA) 4-#i 8AWG TRIP CIRCUIT (WHT/GRN=PWR) ea FACU CELL OPERATION NOTIFICATION APPLIANCE TRIP CKT. MCBL-] UNIT C TRIP COMBINED HORN B VISUAL CIRCUIT) 2'#14AWG G U.L.LISTED CENTRAL STATION ( SS TG7FSV WHEN A FIRE ALARM CONDITION (ALARM, SUPERVISORY OR TROUBLE) I5 DETECTED,THE FIRE ALARM CONTROL UNIT GOES OFF-HOOK TO DIAL THE INITIATING DEVICE CIRCUIT BATTERY BATTERY JOHNSON CONTROLS D IDC 2-#18AWG 4 14200 E IXPOSITION BLVD. CENTRAL STATION.THE DIALER CAPTURE MODULE DETECTS THE OFF-HOOK (NON-INTELLIGENT DEVICES)12V 12AH 12V 12AH MCBL-] a CONDITION AND PROVIDES THE FIRE PANEL WITH A DIAL TONE WHEN THE FIRE AURORA,CO28-72 PHONE PANEL DETECTS THE DIAL TONE,IT BEGINS DIALING THE CENTRAL STATION.THE P POWER 24V NON-RESETTABLE POWER 2-#14AWG xx 1-Bm-428-]i24 DIALER CAPTURE MODULE CONSIDERS THE THREE SECOND PERIOD AFTER rc Qnu��/A d DEDICATED RIL VAC DIALING AS THE NUMBER DIALING HAS BEEN COMPLETED.AFTER THE DIALING IS ®LES SCHWAB 20 AMP Y OTHT(LOCKED) f RT TEST REMOTE TEST STATION TEST 4-#1 BAWG (BY OTHERS) SS000672 COMPLETED,THE DIALER CAPTURE MODULE RETURNS A HANDSHAKE TO THE FIRE PANEL.THE FIRE PANEL THEN SENDS THE CONTACT ID REPORTS TO THE DEDICATED 120 VAC DIALER CAPTURE MODULE,WHICH IN TURN SENDS A KISS-OFF AFTER THE SH=SHIELDED 20 AMP CIRCUIT(LOCKED) REPORT IS SUCCESSFULLY RECEIVED FROM THE FIRE PANEL. THE DIALER 'WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED (BY OTHERS) CAPTURE MODULE SENDS THE CONTACT ID REPORTS TO THE COMMUNICATIONS F E SYSTEM MODULE.WHEN ALL THE REPORTS ARE SENT,THE FIRE PANEL GOES ON-HOOK. LES SCHWAB TIRE CENTER DOCUMENTATION THE COMMUNICATIONS MODULE THEN TRANSMITS THE MESSAGES TO THE s AS-BUILT DRAWINGS CENTRAL STATION. a.� 16607 SMORIN POINT BLVD. Y`q R A ARLINGTON,WA 98223. Y` DESIGNED BY: P.ROJAS DRAWN BY: P.ROJAS 5 t CHECKED BY: 04/25/2025 S� City of Arlington OB/CASE#: 1-91ZJWV1 Building Department APPROVED SHOP DRAWINGS RISER DIAGRAM NOTE Kevin Olander-01/23/2026 DEVICE WIRING SHOWN IS CONCEPTUAL.POINT TO POINT CONNECTIONS MAY VARY.REFER TO FLOOR PLANS FOR REQUIRED EQUIPMENT LOCATIONS.THE ELECTRICAL CONTRACTOR SHALL REFERENCE EQUIPMENT "- INSTALLATION DOCUMENTS,DRAWING TERMINATION DETAILS,AND RISER DIAGRAM FOR COMPLETE EQUIPMENT INSTALLATION. NO Changes authorized unless approved by SHEET: i SHOULD ANY CONFLICT ARISE BETWEEN DESIGNED PLANS,BATTERY CALCULATIONS,VOLTAGE DROPS,AND ACTUAL INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF JCI IN WRITING UPON DISCOVERY AND PRIOR the Building Official TO ELECTRICAL ROUGH. RISER DIAGRAM Ft �e B CALCULATIONS RISER DIAGRAM o� s$ o� FA201 �a 1• •I• •1 30"X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:51 PM LAST SAVED BY:JARAIZM FILE PATH:C:\Users\jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_Arlington_WA_FA_DD01_1-91ZJWV1-REWORKED.dwg o o c. FIRE RATED CONCRETE BLOCKWALL FIRE RATED GPY. WALLBOARD FIRE RATED GPY. WALLBOARD CEILING TO WALL TRANSITION AND OPEN WIRING �� �I C-AJ-1045 W-L-1001 W-L-3149 Johnson CONDUIT PENETRATION U.L.C-AJ-1045 Controls CONDUIT PENETRATION U.L.W-L-1001 GLOBAL JOHNSON CONTROLS 1 OR 2 HOUR RATED CONCRETE BLOCK WALL ASSEMBLY 3M FIRE BARRIER CP 25WB+CAULK OR EQUAL 1 OR 2 HOUR RATED GYP. 3M FIRE BARRIER 142E EXPOSITION AVE#1AR OF NCE WALLBOARD ASSEMBLY CP 25WB+CAULK OR EQUAL CABLE PENETRATION U.L.W-L-3149 AURORA,CO 80012 1-877-330-7404 1 OR 2 HOUR RATED GYP, WALLBOARD ASSEMBLY 3M FIRE BARRIER CP ZSWB+CAULK OR EQUAL 71 PACKING MATERIAL CABLE OR ' CONDUIT CABLE BUNDLE CENTER OF EXCELLENCE NETWORK FIRE ALARM WIRE NOTES: NOTES: NOTES: 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 0 CONDUIT SHALL BE INSTALLED AT CENTER OF STUD CAVITY WIDTH AND 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. CONDUIT KEY 1 PLAN: 2 THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2 THE ANNULAR SPACE BETWEEN CABLE/CABLE BUNDLE AND PERIPHERY OF OPENING SHALL BE BE 0 TO 1-3/8" 0 TO 1". CAULK FILL MATERIAL SHALL COMPLETELY FILL ANNULAR SPACE px 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. BETWEEN CONDUIT AND WALL;AND WITH A WIDTH OF 1/4"DIAMETER 3 MAXIMUM OF V DIAMETER CABLE BUNDLE PER FIRESTOP SYSTEM. PACKING MATERIAL-MINIMUM 4"THICKNESS OF MINIMUM 8 PCF MINERAL 2 BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS OF CAULK MATERIAL-MINIMUM 5/8"THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, THE WALL. FOR CONDUIT 1"DIAMETER AND SMALLER,ANNULAR SPACE 4 FLUSH WITH BOTH SURFACES OF THE WALL.MINIMUM 1/2"DIAMETER BEAD OF CAULK APPLIED WOOL BATT INSULATION SHALL BE FIRMLY PACKED INTO OPENING AS A SHALL BE O TO 3/16". FOR CONDUIT 4"DIAMETER AND SMALLER, AT THE CABLE/WALLBOARD INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. NOTES" 4 PERMANENT FORM. PACKING MATERIAL SHALL BE RECESSED FROM BOTH ANNULAR OF(1)CONDUIT PER FIRE TOP SYSTEM.SPACE SHALL BE 0 TO 1-1/2". 5 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. THICKNESS OF CAULK MATERIAL. 3 M SURFACES OF WALLAS REQUIRED TO ACCOMMODATE THE REQUIRED 1 CONDUIT SHALL BE USED FOR ALL EXPOSED FIRE ALARM CABLING INSTALLED BELOW JOISTS AND BEAMS. 5 CAULK MATERIAL-MINIMUM 1/2"THICKNESS OF FILL MATERIAL SHALL BE 4 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. 2 CONDUIT SHALL BE A MINIMUM OF 3/4". APPLIED WITHIN THE ANNULUS,FLUSH WITH BOTH SURFACES OF THE WALL. CONTACT INFORMATION: DEVICE MOUNTING HEIGHTS POWER DISCONNECT DROP CEILING Et J BOX PHONE CONNECTION DEVICE MOUNTING HEIGHT REFERENCE(PER NFPA 72) .I M x ce sm"ii.o°cw'wsnErz �0M11 DMARC JVL U u IV�oAe xrry uuwPansxno LINE I- RJ 31X BLOCK r nRE aLaRM PANEL FlaE atARM PANEL RED GREEN BLACK a mw eaow Nuisx YELLOW 6 RI CORD RI 31X BLOCK �xevis -la�Y:� °PE LINE TO PHONES n0u iwiLTM�"rTMe cEluxc � romT000aeo•wix ILIs-JI x acme � � O o RED GREEN � w<A rv�P+T� ocTAcoN JUN T'.eax TELCO LINE 9 e L. xNAll—El"'Cx s 1 } au xnn Txax TaPnxovE nxlsxro wax xElcxror a BLACK B R CORD max inu,r xn°°rrtEw ® CONDUIT \ DISTRIBUTION PANEL YELLOW OR RJ CORD FIRE&AW CONTROL PANEL 3eiexxEx�.P,.eaxrxaLP.xr.�x xx.maRxxro IIII O IIIII $$ 0 vsxr°rxuxwx.c°maaLvnx¢sxnu xmxun max w'x (�J�'I CONDUN r� "' PRIMARY PORT E$ DEDIUTED LOCKE 6 CIRCUIT SRELX D g`" O WVLL FIRE ALARM DISCONNECT CO DEDIWED UO VACo30AM BRANCH E e / T�cunm rwr­1 —1 uc CIRCUIT PRIMARY PORT SECONDARY PORT ' HEAT DETECTUR BURGLAR PANEL = m oc -1xR.1TU w PerecmRuc 8 E 000 FIRE ALARM PANEL 40TEG'. SQUARE ar THEcauxc HacUra.i x, JUNCTION Box EGI E5 s" PETEET°xssx"DUL°urz°°xmE CELxa `"` �a DEVICE WIRING STROBE — HORN/STROBE DEVICE WIRING AUDIBLE DEVICE WIRING OS&Y TAMPER SWITCH GATE VALVE WATERFLOW Et BUTTERFLY TAMPER SWITCHES t/P CONDUIT eC u€ "E! cove Tsxnza wrEwisEP FLOWSWITCH u£ / �rszn,[uuxcrox°x za°ivu[rn $= BREAK WIRE I/ s" DO NOT LOOP ""`°`°"" 1/2 WP FLEX CONDOM Ba BREAK WIRE w FIRE RATED DO NOT LOOPrax . SPRINKLER RISER v CABLE STROBE STROBE/HORN + w" O O S T OR EOL _ O O 45 BOX W/COVER PRECEDING HORN O O s ,�, '-"0 CONDUIT +z '-"0 RESISTOR + - + OR POWER SUPPLY NEXT HORN OR EOL °? AT LAST FIRE RATED CABLE q B3 03 DEVICE OR CONDUIT PRECEDING _ EOL BREAK WIRE o / FROM STROBE DO NOT LOOP ° BUTTERFLY TAMPER SNITCH RESISTOR LAST ors. w"rxv�Ea, / e` DEVICE OR POWER AT LAST + _ vrwPFLrxcoNDulr e SUPPLY DEVICE PRECEDING STROBE ISSUE LOG: j DATE INT D SCRIPTI N �= axNaxcaxaan ��NxENPW axxN�a�awaa s= OR POWER SUPPLY NEXT STROBE OR EOL gE :<xa,a�.aP"c axN��a ranwa +r=e WALL NOTES: EgALL 5Y5 9� �o 9 FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION HEAT DETECTOR CELL-CAB-FL HONEYWELL HWF2-COM TELGUARD TG-7FS 5601 P i5 A=31/2-Cetagonalbm - - 9; B=4"Octagonal box - - ED C=Single gang toz and 4"square with plaster dng g SON d1IINR ANTENNA BMx +) Bozaxxebp REMOTE D=Directly to Wall/Ceiling SURFACE-MOUNT 5 ANTENNA ANTE PIER �• INCOMING O 5` TELCO p INS PLATE A c SCHWAB nu A u PHONE p `l�.J, ®�J�V SCHW�B BATTERY WIRING 3 SHOULD BEAT LEAST (D © B A'T :sa 1/4"APART FROM AC O _ WIRES By gE '"'°'"'�'"- TELGUARD �' LES SCHWAB TIRE CENTER s O ® ua r DIGITALTG-7FS Oa dA FLUSH40UM ° BATTERV /1 a5 gFaBriagBaFala; .a, ❑ W C p :oo""off o City R D KWAaHERlington AND NUT i- , ou a ;° O Building fDerpartment ® °„Do ALARM PANEL A ® SIM WlrinR Diagram-aiRRle Olrcult Models: APPROVED 16607 SMOKEY POINT BLVD. Y` ° ano a - _ + ARLINGTON,WA 98223. '°� 1 t ]� STC2 Kevin Olander-01/23/2026 N.C.) e O ® Sq _ $ STC1 TAMPER P3, DESIGNED BV: P.ROJAS (, i z ' o Control Auxiliary E IPOTs-com �t18 woN4❑ (N.O.) SWITCH o Panel EOL OR Device 3a To SACKaox dfg '" I 000"`-000JJJJBB fl o� gATTERy _ No changes authorized unless approved by DRAWN BY P.ROJAS CONNECTOR _ the Building Official CHECKED BY: 04/25/2025 ;5 o EARTH GROUND g ai @� ,- FF, JOB/CASE#: 1-91ZJMI O OO III WY a AC(12V BOOMA) WIH,g Olaaram-Dual OIrcWf Mo4elc: GE L�JL-,Y= BATTERY CONNECTOR TRIP INPUT + SHOP DRAWINGS raInetall door m. Control EOL OR Auxary Auxary �B NOTE:WHEN USING THIS SCHEME,THE USE OF THE PRIMARY OR SECONDARY DIALER TO Panel Auzlllary Auxiliary Device Device e NOTE:THE CELL-MOD(C)/CELL-CAB-FL OFFERS AN OPTIONAL GSM COMMUNICATOR CARD FOR CENTRAL STATION REPORTING.IT MOUNTS CONNECT TO TELCO IS WHAT DETERMINES WHETHER THE TG-71S MEANT TO WORK AS A Device Device SHEET: IN ITS OWN PLASTIC ORMETAL ENCLOSURE.USE OF THE CELL-MOD(C)/CELL-CAB-FL REQUIRES THE IPOTS-COM COMMUNICATOR. BACK-UP OR PRIMARY COMMUNICATOR. - USE EITHER AC POWER(FROM ADAPTER)WITH BATTERY OR USE DC POWER(FROM PANEL). 5E PRODUCT TYPICALS �6 A PRODUCT TYPICALS o� o� FA301 �a • 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:55 PM LAST SAVED BY:JARAIZM FILE PATH:CAUsers\jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_Arlington_WA_FA_DD01_1.91 ZJWV1-REWORKED.dwg Permit#: 6633 Permit Date: 07/18/25 Permit Type: FIRE ALARM Project Name: Les Schwab-114015943-13 Applicant Name: Johnson Controls Security Solutions, LLC/Johnna Lambert Applicant Address: 7815 S. 180th Street Applicant, City, State, Zip: Kent,WA 98032 Contact: Johnna Lambert Phone: 5032014772 Email:johnna.lambert@jci.com Scope of Work: NEW FIRE ALARM SYSTEM. Valuation: 33191.00 Square Feet: 16404 Number of Stories: 2 Construction Type: 113 Occupancy Group: B; Business ID Code: Permit Issued: 09/09/2025 Permit Expires: 09/09/2026 Form Permit Type: FIRE ALARM Civic Plus Number: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052800204300 16607 SMOKEY POINT SFP-B LTD PTNSP 552 Tires,Batteries BLVD &Accessories Contractors Contractor Primary Contact Phone Address Contractor Type License License# Johnson Controls Johnna Lambert 503 201 4772 7815 S 180th St CONSTRUCTION COA 601636830 Security Solutions,LLC CONTRACTOR Johnson Controls Johnna Lambert 503 201 4772 7815 S 180th St CONSTRUCTION L&I JOHNSCS7725H Security Solutions,LLC CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Fire Alarm Tested,5 minute FA00.FIRE ALARM ring down,all points 06/05/2026 FINAL reported for pulls,smokes, 07/10/2026 07/10/2026 FIRE Approved heat,waterflow,fire pump, and backflow 05/26/2026 FA00.FIRE ALARM scheduled for 9:30am 05/29/2026 05/29/2026 FIRE Canceled FINAL 05/26/2026 FA00.FIRE ALARM scheduled for 9:30am 05/29/2026 FIRE Assigned FINAL 03/02/2026 FA00.FIRE ALARM Scheduled for 9:30am 03/09/2026 FIRE Canceled FINAL 03/02/2026 FA00.FIRE ALARM Scheduled for 9:30am 03/09/2026 BUILDING Canceled FINAL Scheduled for loam FA00.FIRE ALARM Fire on site at 10:00 no O1/28/2026 02/O5/2026 02/04/2026 BUILDING Canceled FINAL representative from alarm Co on site O1/28/2026 FA00.FIRE ALARM Scheduled for loam 02/05/2026 FIRE Canceled FINAL 11/04/2025 FA00.FIRE ALARM Scheduled for 9am 11/13/2025 BUILDING Canceled FINAL 11/04/2025 FA00.FIRE ALARM Scheduled for 9am 11/13/2025 FIRE Canceled FINAL Plan Reviews Date Review Type Description Assigned To Review Status 08/27/2025 FIRE ALARM Pending fire approval. BUILDING Approved with Conditions 08/27/2025 FIRE ALARM FIRE Approved O1/21/2026 FIRE ALARM Revisions were made in the field that were not part of the BUILDING Approved approved plans. 01/21/2026 FIRE ALARM Revisions were made in the field that were not part of the FIRE Approved approved plans. Fees Fee Description Notes Amount Enter 1 if permit is for:fire alarm,or fire Web Only-Fire System Plan Review sprinkler $200.00 Credit Card Service $6.00 Processing/Technology $25.00 FACP/Transmitter-New $200.00 Fire Alarm System Permit NFPA 72- 105.7.3 $350.00 Credit Card Service $17.25 Permit Extension $110.00 Credit Card Service $3.30 Total $911.55 Attached Letters Date Letter Description 09/09/2025 Building Permit 07/18/2025 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 07/21/2025 XBP Conf: $200.00 237766608 07/21/2025 Johnna Lambert 237766608 Hannah Hardwick $6.00 09/09/2025 XBP Conf: $575.00 242432913 09/09/2025 Johnna Lambert 242432913 Hannah Hardwick $17.25 03/09/2026 Tammi Lankenau 307700571 $3.30 03/09/2026 XBP Con£ $110.00 307700571 Outstanding Balance $0.00 Notes Date Note Created By: 03/02/2026 sent expiration notice Hannah Hardwick 02/02/2026 Expiration Notice LaNay Pray 08/27/2025 Revised plans received. Kristin Foster 08/05/2025 Emailed fire comments for revisions. Kristin Foster NEW FIRE ALARM SYSTEM.THE NEW SYSTEM SHALL INCLUDE: •AN ADDRESSABLE FIRE ALARM CONTROL UNIT. -AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. •A DOCUMENT BOX IS TO BE INSTALLED BY THE CONTROL UNIT. •A FIRE ALARM ANNUNCIATOR IS TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. •A SMOKE DETECTOR IS TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT THE ELECTRICAL ROOM. •MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN 5' OF EGRESS DOORS. •WALL-MOUNTED HORN/STROBES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. •WALL-MOUNTED STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. •A WEATHER- PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE 07/18/2025 Kristin Foster SPRINKLER ROOM. •MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. •MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. • 120VAC SURGE SUPPRESSORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. •MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS.THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES.THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM&EXISTING DUCT DETECTORS.THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE ALARM CELLULAR COMMUNICATOR.THE BUILDING IS FULLY SPRINKLERED. 07/18/2025 Contractor needs COA license prior to issuance.Sent the link to add it as an endorsement. Kristin Foster Uploaded Files Date File Name 01/26/2026 30411239-Approved As-Builts.pdf O1/21/2026 30358041-Les Schwab-114015943-13 AS BUILT revisions.pdf 09/09/2025 28181271-20250909 BLD6633 IssuedPermit.pdf 08/27/2025 28007762-20250826 BLD6633 RevisedSubmittalBooklet.pdf 08/27/2025 28007760-20250826 BLD6633 RevisedPlans.pdf 07/18/2025 27407802-20250718 BLD6633 Data Sheet.pdf 07/18/2025 27407803-20250718 BLD6633 Cut Sheet.pdf 07/18/2025 27407804-20250718 BLD6633 Plans.pdf 07/18/2025 27407805-20250718 BLD6633 Application.pdf o FIRE ALARM NOTES Johnson Controls 1. ALL APPLICABLE CODES SHALL BE OBTAINED PRIOR TO START OF WORK JOHNSON CONTROLS 2. THE SYSTEM SHALL BE LOW VOLTAGE,PROTECTED PREMISES FIRE ALARM/CENTRAL STATION SERVICE,ALARM SIGNALS SHALL BE RECEIVED AT JCI'S CENTRAL GLOBAL CENTER OF EXCELLENCE STATION AT: 142M E EXPOSITION AVE#1A 14200 E.EXPOSITION AVE. AURORA,co eoolz DO AL BERATED OR THE ENVIRONMENT li' � �� �� 1-ena3o-7404 3. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING TO THE REQUIREMENTS OF NFPA72 AND THE MANUFACTURES INSTRUCTIONS. i4. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED.5. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. 6. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 10%.(SEE CALCULATIONS). 7. ALL FIRE ALARM DEVICES ARE TO BE U.L LISTED AND COMPATIBLE. The Lodge Apartments Q 2 E 17 1NE a B. ALL WIRE IS TO BE IN CONDUIT FROM DEVICE BACK BOX TO ABOVE FALSE CEILING OR TO THE BAR JOIST.WIRE MAY RUN EXPOSED HORIZONTALLY,BUT MUST BE Una Beauty GoPainters Alley N 'a - CENTER of Ex ceuENGE NETwoRK 1 lahsr NE Benjamin Moore ®. SUPPORTED PER NFPA 70 REQUIREMENTS. Benjamin �% ©Skagit Regional Health-Smokey Point IDl:lnsulati, 9. ALL WIRE SHALL BE POWER LIMITED,FPLP UNLESS OTHERWISE NOTED. Hobby Lobby Q O Bonefish Grill M°ure Pa�ats Q Distributors Ii ouaaan cull® 10. WIRE ROUTING SHOWN IS DIAGRAMMATICAL AND DOES NOT REPRESENT ACTUAL RUNS.WIRE LAYOUT IS SUBJECT TO CHANGE AS NEEDED BY THE INSTALLING Crumb)-Ma II Amamn Fulfillment KEYPLAN: CONTRACTOR. CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS OR PANELS MAXIMUM SIGNAL LINE CIRCUIT Marysville� Center PAE2 CAPABILITIES. Galbi Burger Walmart Supereeni ®eur9=,skis:, Best BUY 0, and Daaks 11. UNLESS OTHERWISE REQUIRED BY INS ANNUNCIATOR/KEYPADS TO BE MOUNTED-4 5IN ABOVE THE FINISHED FLOOR TO THE TOP OF THE UNIT. LES S C H WA B TIRE CENTER jLakewo.. 12. MANUAL PULL STATIONS SHALL BE INSTALLED WITH THE OPERATIONAL PORTION 42-48 INCHES ABOVE FINISHED FLOOR. Target Qen,Q 0 p'Reiylq Auto Parts irts 13. ALL VISUAL DEVICES SHALL HAVE THE CANDELA SET PER APPROVED PRINTS.CANDELA VALUE NOTED NEAR THE DEVICE ON DRAWINGS. sing14. CEILING MOUNTED NOTIFICATION DEVICES ARE NOTED WITH A"C". o •Les Schwab Tire Center Coster,Wholesale15. DESIGN IS BASED ON:CONTRACT DRAWINGS,ENGINEERED PROVIDED PLANS,SITE SURVEY.ALL EQUIPMENT IN THIS DESIGN SHALL BE INSTALLED PER ITS LISTED eo area Gas Station 1-1,PI NE USE. Public Storage ,e a o� 16. DEVICE LOCATIONS ARE BASED UPON APPLICABLE CODE,MANUFACTURES INSTALLATION INSTRUCTIONS,AND ACCEPTED INSTALLATION PRACTICES.SHOULD ANY Q 8 Vt 16607 SMOKEY POINT BLVD. petso n age= P P o CONTACT INFORMATION: UNKNOWN CONDITION BE DISCOVERED DURING INSTALLATION WHICH CONFLICTS WITH APPLICABLE CODE,IT SHALL BE BROUGHT TO THE ATTENTION JCI IN WRITING PRIOR TO INSTALLATION. ARLINGTON, WA 98223. 17. THE TOTAL SOUND PRESSURE LEVEL PRODUCED BY COMBINING THE AMBIENT SOUND PRESSURE LEVEL WITH ALL AUDIBLE NOTIFICATION APPLIANCES OPERATING SHALL NOT EXCEED 110 DBA AT THE MINIMUM HEARING DISTANCE. Gissber 18. A FIRE ALARM SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 DBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND Twin La 8 Marysville Toyota LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS. CascadeParkB1 'f II Ford G of 'rysvillev SHEET INDEX FDrreste wDodBnaes � _ SHEET DESCRIPTION VICINITY MAP ABBREVIATIONS IN INCHES FA000 COVER SHEET scALL.H s KW KILOWATT FA101 DEVICE PLACEMENT PLAN SYMB DESCRIPTION LVL LEVEL FA201 RISER DIAGRAM i CALCULATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUM FA301 PRODUCT TYPICALS AFG ABOVE FINISHED GRADE MIN MINIMUM AMP AMPERE MNS MASS NOTIFICATION SYSTEM AUX AUXILIARY MTD MOUNTED AWG AMERICAN WIRE GAUGE N4 NEMA4-NON CORROSION-PROOF Y ENCLOSURE BFG BELOW FINISH GRADE N4X NEMA4-CORROSION-PROOF 3 e BLDG BUILDING ENCLOSURE N12 NEMA 12-SEALED ENCLOSURE g C CEILING MOUNTED NAC NOTIFICATION APPLIANCE CIRCUIT CIRC CIRCUIT # NUMBER SCOPE OF WORK 5= PNL PANEL NEW FIRE ALARM SYSTEM. V COND CONDUIT PH PHASE THE NEW SYSTEM SHALL INCLUDE: e= ON DOWN PS POWER SUPPLY AN ADDRESSABLE FIRE ALARM CONTROL UNIT. tm DWG DRAWING OTY QUANTITY • AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. z SEC SECONDARY A DOCUMENT BOX IS TO BE INSTALLED BY THE CONTROL UNIT. DEGREE SiIGNAL LINE CIRCUIT • A FIRE ALARM ANNUNCIATOR IS TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. ° A SMOKE DETECTOR 15 TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT ELEC ELECTRICAL TEMP TEMPERATURE THE ELECTRICAL ROOM. EXT EXTERIOR MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN 5'OF EGRESS DOORS. eg TYP TYPICAL • HORN/STROBES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. 8 EX EXISTING DEVICE V VOLTAGE • STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. E EQUIP EQUIPMENT VAC VOLTAGE ALTERNATING CURRENT • A WEATHER-PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE SPRINKLER ROOM. as • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. 5 XP EXPLOSION PROOF W WATTS • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. FIRE ALARM SYMBOLS FA FIRE ALARM WP WEATHERPROOF • 120VAC SURGE SUPPRESSORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. WG WIRE GUARD • MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS. QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX FL FLOOR WD WIRELESS DEVICE € FT FEET THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES. W/ WITH 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN GND GROUND v€ THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM ft EXISTING DUCT DETECTORS. § THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ALARM CELLULAR COMMUNICATOR. &; ,a THE BUILDING IS FULLY SPRINKLERED. s m 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R c= BEFORE INSTALLATION OF ANY SYSTEM COMPONENT,THE INSTALLATION TECHNICIANS SHALL CONFER AND COORDINATE WITH THE GENERAL CONTRACTOR AND ALL OTHER APPLICABLE TRADES TO ENSURE THE INSTALLATION LOCATION WILL NOT CONFLICT WITH OTHER TRADES. 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN ALL WIRE SHALL BE OPEN-RAN OR CONCEALED IN THE WALLS OR CEILINGS.WHERE THE WIRE IS BELOW 10',IT SHALL BE INSTALLED IN Y"EMT CONDUIT. 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN 4E - UPON AHJ'S ACCEPTANCE OF THE NEW SYSTEM,THE EXISTING SYSTEM SHALL BE REMOVED. Y "€ 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D Ea 7 FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG ISSUE LOG: �^ 6 AIM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D gE fr§ FIRE ALARM MATRIX/SEQUENCE OF OPERATION 2 AIM D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D x SYSTEM OUTPUTS e 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQ x 2.5"D Z o z s i o 0 8 \4 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 2.5"D - - o s� CODE ANALYSIS w z O B BUILDING OCCUPANCY TYPE M,B,5.1 o w u o 4 �o HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQ x 2.5"D z C NUMBER OF STORIES TWO(2) ¢ zo i oti Ca z e$ PROJECT AREA 16 404 SQ.FF. ¢ o ' o i_ 0 5 o HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D s G r f O L. z w U TYPE OF SYSTEM ADDRESSABLE INITIATION 8:CONVENTIONAL NOTIFICATION w z z a, w z 11 iLISTING AGENCIES(UL,FM,MEA,ULC) UL 864 o w m o w o ¢ G°1 le ° 0 1 HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED Ja� WIRING TYPES OPEN CEILING,CONDUIT w O �' �' z J z WP J a Q z _ z _ z - , = z w w TYPE OF COMMUNICATION REMOTE STATION ¢ o z i 0 w ° i a i o ti a m a 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN AUDIBLE NOTIFICATION TEMPORAL 3 w w ❑ ❑ O a s a o qa Z qa z •1 ❑ w z 3 LES SCNWAB E8 VISUAL NOTIFICATION PUBLIC MODE O ran I m O o o c 2 y ❑ z Oo a w z m H d re z o! z a z z z w ❑ o z z 2 �5 SMOKE DETECTOR-DUCT EXISTING BUILDING SPRINKLER SYSTEM FULLY SPRINKLERED O ❑ H w z i O O_ z O O_ O O O O O_ H ¢ a i ❑ r r O r F tJ r ul O w❑ 0 O Z Z fir U) ❑ a a N a a j a > W w ul FE STANDARDS NFPA 72(2019),NFPA 70(2017) O o: ❑ w ❑ O r ❑ O r g r r y H F LES SCHWAB TIRE CENTER @= z z a f Z to `i Z to R' Z w rD Z In Z N1 O w z -s APPLICABLE CODES IBC 2018,IFC 2018,IMC 2018 ASME/ANSI A717.1 2017 p o c, ❑ o: ❑ O ❑ O i ❑ O > > O F ❑ E O H ❑ 2 ® REMOTE ALARM INDICATING AND TEST SWITCH EXISTING ( 1 ( 1 ( ) ( I 3 O O r o H w g z z g z z z z O z z z w w z o O RTS F O O 3 O `a W W O W W O N W O N W O w - 0 w I K 2 Z > Z Z Z Z N H U a z z > aUww a w s 0 a s La 0 La w KNOX BOX EXISTING o WdW Wf W WZ C, ZI F F O O O O U O U O L O L O w 16607 SMOKEY POINT BLVD. 0z m > ❑ a ¢ ra ra r aSYSTEMINPUTS O 2 FLOW DETECTOR/SWITCH EXISTING ARLINGTON,WA 98223. CONTROL UNIT FUNCTIONS "ALL SYSTEMS NORMAL" X B SYSTEMSILENCE X X DESIGNED BY: P.ROJAS a& SYSTEM RESET ONE POINT FOR RESET x x 1 HP HIGH AIR PRESSURE SWITCH EXISTING DRAWN BY: P.ROJAS s`a DRAWING ACCEPTANCE ALARM DEVICES s CHECKED BY: 04/25/2025 WANUAL PULL STATIONS ES X X X X X 52 THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JON CON CONTROLS EQUIPMENT AND IS NOT TO MANUAL PULL STATIONS X X X X X 1 LP LOW AIR PRESSURE SWITCH EXISTING JOB/CASE#: 1-91ZJWV1 BE USED FOR ANY OTHER PURPOSES.IT IS THE RESPONSIBILITY OF THE LOCAL JOHNSON CONTROLS SALES @SERVICE OFFICE(SS0) SMOKE DETECTORS X X X X X TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. SUPERVISORY DEVICES s RECORD DRAWINGS SPRINKLER TAMPER SWITCHES X X X 11 VALVE-GENERAL EXISTING ➢$ AIR PRESSURE SWITCHES X X X SHOP DRAWINGS ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JOHNSON KNOX BOX TAMPER SWITCH X X X p q A� CONTROLS OFFICE AT THE ADDRESS LISTED ABOVE. DUCT SMOKE DETECTORS X X X X V MONITORING LOCATIONS TROUBLE FUNCTIONS 1 1 y SIAMESE FIRE DEPARTMENT CONNECTION EXISTING SHEET: LOSS OF DIAL TONE OR CELL DIALER CONECTION X X X `-; JOHNSON CONTROLS ALARM SERVICE CO:544525 FIRE ALARM SYSTEM AC POWER FAILURE X X X 1420D EXPOSITION AVE. ILL LISTING:S994-183 AURORA,CO.80012 FIRE ALARM SYSTEM LOW BATTERY X X x COVER SHEET 1-800-428-7124 ABNORMAL CIRCUIT OR DEVCE X X X �e 3 ORDER OF OPERATIONS DE VICE EVICE LEGEND L s$ FA000 o� �a 1 •I. 1 •1 30"X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:41 PM LAST SAVED BY:JARAIZM FILE PATH:C:\Users\jaraizm\OneDrive-Johnson ContmLs\Desktop\hhh\LSTC_ArLington_WA_FA_DD01_1-91ZJWV1-REWORKED.dwg o o o FIRE ALARM SYMBOLS 'Johnson �� �� Approved QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBO% Controls Steve Goforth,Fire Marshal 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-200X OWN �1 JOHNSON CONTROLS Subject to Field Review GLOBAL CENTER OF EXCELLENCE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN 142M E EXPOSITION AVE#1A `J AURORA,CO 8DO12 01/26/2026 10:58:01 AM 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SBSOKIT-R 1-877-330-7404 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-1 OWN �✓ 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SSUOD672 OWN 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D CENTER OF ExCELLENCE NERNORK 7 �F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG 6 aM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D KEYPLAN: �M20 FIRES 2 aMD DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx2.5"D M79 II r",M18 PUMP I 1 uM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D M17 IMIS i z aM10 MI5 '^ I 8 M STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQx 2.5"D M14 MOS 1 I I¢ >M13 AIMF�, ¢ 30 ¢ I 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQx 2.5"D M12 S C �DQ M71 � 5 �o HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D EOL I AIM M10 AIM AIM AIMMO51 CONTACT INFORMATION: I A 9 07 M 6 I�p 6 / 1 WP HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENIOR P2RK INCLUDED WP / 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN MECH.RM. AA F M21 A FAA MF AA C/� Z �S SMOKE DETECTOR-DUCT EXISTING ¢ L J, 95 CD ¢ 5 RINKLER ROOM TOFU 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING CEILING OVER 75 CD SHOWROOM IS JB BELOW ¢ o C TO FACU LEC. S D02 ¢ 1 KB KNO%BOX EXISTING OOM p TO JDOI�MIE-) FACU RTU#1LL 2 FLOW DETECTOR/SWITCH EXISTING __ ALIGMENT BAYS¢ ¢ 1 HP HIGH AIR PRESSURE SWITCH EXISTING RTUL-- D_—RT_�" i RTS SHOWROOM CB CB C8 C8C8 i - \75 CD 1 LP LOW AIR PRESSURE SWITCH EXISTING ¢ o `-'_ ALIGMENT FIT a 11 DQ VALVE-GENERAL EXISTING SS OFF CE g a STORAGE R 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING I �C9C 9�9 C9 C9C9� ,:E STAIRS ¢ TAIRS �30 CD a> s 2� E� HALL ¢ ¢ PARTS ROOM TO FACU I GENERAL NOTE 1)ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. gIR REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. TO MAIN I FROM 2N a 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT €o F M04 LEVEL LEVEL I LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS. E� 95 CD I 115 CD 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD g @ a ° a VERIFIED. C TO FACU M27 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 Ea 30 CD (NATIONAL ELECTRIC CODE). 5 ¢ ¢ F 5)WHERE CONDUIT IS REQUIRED,MINIMUM SIZE SHALL BE 3/4". a 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE PATH. d c WAREHOUSE 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE 150 CD € a HALL V C9 u a ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. v€ C WAREHOUSE UNLOADING I CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO n DIAGONAL RUNS ARE PERMITTED. SALES AREA c I I 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. i8 a a s 8 a Ll>JCD 1 CD 95 CD LOCKERRM. FLAG NOTES NEW FIRE ALARM CONTROL UNIT SHALL BE CONNECTED TO DEDICATED 120 VACPOWER.LABEL CKT BREAKER"FIRE ALARM". 5 O STATION FIRE ALAVIAC OLEROL ATHNIT SHALL COMMUNICATE TO CELLULAR COMMUNATION.MONITORING MONITOR MODULE FOR FIRE ALARM CELL DIALER COMMUNICATOR TROUBLE 15SUPERVISION. 15 MONITOR MODULE FOR NAC POWER SUPPLY TROUBLE SUPERVISION. DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF WATERFLOW ISSUE LOG: - SWITCH. � INSTALL EXTERIOR HORN STROBE NEXT TO THE SPRINKLER ROOM. g E ¢ EOL �"9 75 CD ®i 10 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVES. fr§ 115 CD EOL C9 F g ¢ C C7 C7 C7 M23 ®8 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVE. e ¢ MONITOR MODULE INSTALLED FOR SUPERVISION OF FIRE PUMP. SALES AREA 5 ¢ SERVICE BAYS 10 PRESSURE SWITCHDUAL MONITOR ODULE INSTALLED FOR AT THE DRY SYSTEM RISER.RVISION OF HI/LOW AIR b;= 2 N D LEVEL CLOUNGER ¢ 11 FIEELD VERIFYDOCAT LOCATION. OF EXISTING DUCT DETECTORS. g� a a� ^B YGLij1M22 AFROM 75 CFACU C7- ADF FAA AAA AA -, AAAAAAAAJB ! p WIRE CHART ®LEs SCHWAB; MAIN LEVEL CIRCUIT �MINIM2-#18AUMSIZE< SYMBOL CIRCUIT DESCRIPTION TYPE AND TYPE OF WIRE g A SIGNALING LINE CIRCUIT A SLC (POWER LIMITED) 2-#18AWG LES SCHWAB TIRE CENTER s ANNUNCIATOR DATA BUS AD ANN (BLK/RD=DATA) 4-#18AWG a,§ (WHT/GRN=PWR) NOTIFICATION APPLIANCE TRIP CKT. ER C TRIP (COMBINED HORN B VISUAL CIRCUIT) 2-#14AWG A 16607 SMORIN POINT BLVD. D IDC INITIATING DEVICE CIRCUIT 2#iBAWG (NON-INTELLIGENT DEVICES) ARUNcioN,WA 98223. P POWER 24V NON-RESETTABLE POWER 2-#14AWG DESIGNED BY: P.ROJAS RT TEST REMOTE TEST STATION TEST 4-#18AWG DRAwN BY: P.ROJAS 5CHECKED BY: 04/25/2025 e� SH=SHIELDED "WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED JOB/CASE u: 1-91ZJVN1 SHOP DRAWINGS ALB e SHEET: 5E DEVICE PLACEMENT PLAN �e A�1 DEVICE PLACEMENT PLAN o s s$x N SCALE 18 1.8' N FEET) O � 6 rAA o� �a 11 I •11 I •1 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:46 PM LAST SAVED BY:JAAIZM FILE PATH:CAUsers\jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_ArLington_WA_FA_DD01_1.91 ZJWV1-REWORKED.dwg o FACP BATTERY CALCULATIONS Alarm i Tptal Total CIRCUIT LOAD&VOLTAGE DROP CALCULATIONS Johnson Dry Part# DescriPllon Standby Alarm stlntleY 0 1 ES-200X Fire NarmParel 0.14100 0.25700 0.1410 0.00 Source: NAC#1 Controls 1 PWR 1324 Optional 24.1t 3 Amp Tmmformer(imkle the"" 0.00700 DOD800 0.0070 0.0080 Circuit Number' 1 IPOTSCOM POTS-ormanicaror(inside the panel) 0.woo 0.04100 awo awo Device DeacrI tlon Standby Alarm C5 C6 C7 C8 C9 JOHNSON CONTROLS 1 AN Remote Pnnunciator 0.0150D 0.woo 0,0150 0.040D wit2 SD365 Ph-electdo Smoke Detector 0.00020 DOMED ODOM 0.0090 WALL MOUNT STROBE RED(15 cd) 000000 0.01800 1 0018 2 0036 0 0 0 0 0 0 GLOBAL CENTER OF EXCELLENCE 7 BG12LX M ll-I Pull Station 0.00038 0.00500 DOOM DOWD ALL MOUNT STROBE RED(30 cd) 0.00000 0.02200 0 0 0 0 0 0 0 0 3 0.066 FIRE ALARM SYMBOLS 142M E EXPOSITION AVE MIA 8 MvF3 odule 00 Wnitor Mh LED(Full S¢e) 0.00038 0.00500 0.0030 0.0400 WA L MOUNT STROBE RED(75 cd) 000000 007000 0 0 0 0 1 007 1 007 0 0 AURORA,CO 8W12 2 MDF300 Dual Mbnitor Mbdule 0.00075 0.00640 0,0015 0.0128 I OEILING MOUNT HORN STROBE RED(75 cd) 000000 0.08700 0 0 0 0 1 0.087 0 0 0 0 QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX 1 MhF3oP10 Ten-Input Monitor Mlotlule 000035 0.00550 o.olxl4 0.0055 I CEILING MOUNT HORN STROBE RED If 15 cd) 0.00000 0.12000 0 0 0 0 2 0.24 0 0 0 0 1-87]-330-7404 1 FL-PS10 NAC BD.-Power Supply(Trgger Current) acoloo0 0.=w 0.0000 0.0020 SPARE SPARE CEILING MOUNT HORN STROBE RED(1 d)cd) 000000 0.08700 0 0 0 0 0 0 0 0 1 0.087 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN 0.2529 0.5603 ALL MOUNT HORN STROBE RED(75 cd) 000000 0.08700 0 0 0 0 0 0 0 0 1 0.087 �L, WALL MOUNT HORN STROBE RED(95 cd) 0.00000 0.09200 2 0.184 0 0 0 0 1 0.092 0 0 r��` Standby Current Total Hours- 0.2529 X 24 = 6.0690 ��, Ours) ALL MOUNT HORN STROBE RED(135 cd) 000000 alesoo 0 0 0 0 0 0 0 0 1 a18s 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ���''� Alarm Current Total Ml= 0.5603 X.083 - o.ows WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 0 0 1 0.212 0 0 0 0 0 0 (S Mns) #Devices 3 0202 3 0248 4 0.397 2 0.162 6 0531 0 0ED0 ITotal 6.1155 Ciruh Amps 0202 0248 0397 0162 G.531 0000 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R CELLENCE NEIVIORK 20 Badery safety rM6 - 1 z231 Cil Length(ft) 80 200 300 270 300 180 Total Voltage Drop(14awg) 0.10 0.32 0.76 0.28 1.02 0.00 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN Total ANRates Baneries Needed = 7.3386 Total EDE Volta a 14 aw 20.30 20.08 19.64 20.12 19.38 20.40 Total AN Rated Batteries Supplied F 12 NOTE: VOLTAGE FORMULA USED IS: 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN KE P AN: NAC#1 BATTERY CALCULATIONS Total VD=LENGTH(CIRCUIT MEASURED ONE-WAY IN FT.)X LOAD(IN AMPERES)X RESISTANCE(.00316 FOR 14AWG)X 2(FOR RETURN RESISTANCE) Total Dty Part# Description snnaby warm snnany warm 2 OP SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D 4 SRLED WALLMOUNTSTROBE RED(15od) 0.00000 0.01800 0.0000 0.07zo WIRE RESISTANCE VALUES REFERENCED FROM NEC TABLE 8 2 SRLED WALLMOUNTSTROBE RED(30cd) 0.000DO 0.0220D 00000 0.0440 2 SRLED WALL MOUNT STROBE RED(75 od) 0.00000 0.07WO 0.0000 0.1400 7 �F FIRE ALARM PULLSTATION FIRELITE BG-12LX IGANG 1 PC2RLED CEILING MOUNT HORN STROBE RED(75 pd) 0.00000 0.08700 O.ODDO 00870 TG-7FS-V BATTERY CALCULATIONS 2 PC2RLED CEILING MOUNT HORN STROBE RED(115 cd) 0.00000 0.12WO 0.0000 0.2400 1 PC2RLED CEILING MOUNT HORN STROBE RED(15o cd) 0.00000 Dial 0.0000 0.1890 Total Total 6 AIM ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D 1 P2RLED WALL MOUNT HORN STROBE RED(75 cd) 0.00000 0.08700 00000 0.0870 Qty Part# Description Stantlby Alarm Stand by Alarm 3 P2RLED WALL MOUNT HORN STROBE RED(95 cd) 0.00000 0.09200 0.0000 0.2760 1 TG7FS-V Cell Dialer Communicator 0.08300 023000 0.0830 02300 1 P2RLED WALL MOUNT HORN STROBE RED(135cd) 0.00000 0.18900 0.0000 0.1890 0.0830 02300 2 AIM DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D 1 P2R WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 0.0000 0.2120 D 0 00001 1.5360 Standby Current Total Hours= 0G83G X 24 = 1.9920 CONTACT INFORMATION: Standby Cx°erd T-1 Fbx,s= o000o x. = 0OWD (Hours) 1 AIM 70 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4"SQx 2.5"D (Hours) Alarm Current Total Minutes= 02300 X G83 - 0.0191 Alarm Current Total Minutes= 1 53Go x O8s = o 1275 (5 Mins) / (5 Mns) Total = 2.0111 8 ,4. STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQx 2.5"D Tutal = 0.1275 20%B,sery Safety M agin - 0.0255 20%Battery Safety Margin = 0.4022 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQx 2.5"D C Total AN Rated Batteries Needed = D.153D Total AH Rated Batteries Needed = 2.4133 5 � HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQx 2.5"D Total AH Rated Baaeries Supplied F 7 Total AH Rated Batteries Supplied 7 1 WP�'O HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED A' CALCULATIONS CALCULATIONS 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN 2 'S SMOKE DETECTOR-DUCT EXISTING 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING 95 CD 95 CD 15CD CIR5 EOL 14AWG Ra 1 KB KNOX BOX EXISTING % 2 COND FPLP QQ CIR6 110 CD 2 r V FLOW DETECTOR/SWITCH EXISTING r� $S EOL 14AWG s 2 COND xe 1 HP HIGH AIR PRESSURE SWITCH EXISTING FPLP 9a y CIR7 75 CD 115 CD 115 CD 75 CD EOL 1 LP LOW AIR PRESSURE SWITCH EXISTING N= 14AWG C C C RE c z CONE, == FPLP 11 VALVE-GENERAL EXISTING % 95 CD CIRB 75 CD _ 14AWG ARE 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING E 2 COND FPLP E E 135 CD 75 CD 150 CD E.m CIR9 30 CD \130 CID � _30 CD � EDE Y$ 14AWG C r�RE 2 COND FPLP %C CIR10 ar CO14A D SPARE FIRE PUMP 2 2 CONE, C_RTU 1_�_ F FPLP DOI Moi M02 I M03 M04 DOz MOS Mae .7 stuooP A F s GENERAL NOTE v8 CIR11 EOL SPARE 18 AWG/2 CONE,,FPLP P I ant D I P RavERaul M DD14A 11 ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. E; 2CO D a I P- PowTR MOH Aw9 REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. _= 2COND NO CHANGES TO FACU EXISTING NOTIFICATION APPLIANCE CIRCUITS I S EOL s m cs c6 o ca c9 ClD C10 �� I RT I s x s x n 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT S= T xl IN 0 IC to AP E5 CI I I LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP RTS �EDLio uEEOLo su E0� EOLy EOL CALCULATIONS. D N M FV IR IT. q 0 G L___J 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD VERIFIED. 5= 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 _- NAC#1 IN ELECTRIC CODE). ° FL-PSio M23 M22 M21 M10 5)WHERE CONDUIT IS REQUIRED,MINIMUM SIZE SHALL BE 3/4". E sT IF AT N L c F F F ant aN 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE 0 T DI C U 4 A G D PATH. Y z N EOL 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE BATTERY BATTERY EOL FP ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. i" 12V 7AH iZV 7AH Re D D D D D D D D D D CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO M:o� Mid M,� MtT NrsI MtI MINI NnI Mtx� Mt� DIAGONAL RUNS ARE PERMITTED. 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. keg DEDICATED 120 VAC 0 IS NG on'IC 0 P EOL EOL EOL EOL EOL EOL EOL EOL EOL EOL 20 AMP CIRCUIT(LOCKED) D 0 0 FY R T. A ISSUE LOG: (BY OTHERS) 2 N -E Na DESCRIP'n N FP M26 M27 M28 INDI 0-PRO PRO-D LAYOUT ;W5 F F AIM D CI ;M24 DE TI N IF AT LI C 0 T DI CI UI 4 G F% 2 0 FP e WIRE CHART C C C3 C4 A SYMBOL CIRCUIT CIRCUIT DESCRIPTION >MINIMUM SIZE< 9 TYPE AND TYPE OF WIRE - - w= is Awc ^^ A SLC SIGNALING LINE CIRCUIT 2.#18AWG 4 COND /�/ (POWER LIMITED) FIRE LITE FPLP `\�()�� ANNUNCIATOR DATA BUS ES-20OX \ TG-7FS-V BASIC SYSTEM FUNCTIONAL AD ANN (BLK/RD=DATA) 4-#i 8AWG TRIP CIRCUIT (WHT/GRN=PWR) ea FACU CELL OPERATION NOTIFICATION APPLIANCE TRIP CKT. MCBL-] UNIT C TRIP COMBINED HORN B VISUAL CIRCUIT) 2'#14AWG G U.L.LISTED CENTRAL STATION ( SS TG7FSV WHEN A FIRE ALARM CONDITION (ALARM, SUPERVISORY OR TROUBLE) I5 DETECTED,THE FIRE ALARM CONTROL UNIT GOES OFF-HOOK TO DIAL THE INITIATING DEVICE CIRCUIT BATTERY BATTERY JOHNSON CONTROLS D IDC 2-#18AWG 4 14200 E IXPOSITION BLVD. CENTRAL STATION.THE DIALER CAPTURE MODULE DETECTS THE OFF-HOOK (NON-INTELLIGENT DEVICES)12V 12AH 12V 12AH MCBL-] a CONDITION AND PROVIDES THE FIRE PANEL WITH A DIAL TONE WHEN THE FIRE AURORA,CO2 PHONE PANEL DETECTS THE DIAL TONE,IT BEGINS DIALING THE CENTRAL STATION.THE P POWER 24V NON-RESETTABLE POWER 2-#14AWG xx 1-Bm-428-728-]i24 DIALER CAPTURE MODULE CONSIDERS THE THREE SECOND PERIOD AFTER rc Qnu��/A d IL OCKED) DIALING AS THE NUMBER DIALING HAS BEEN COMPLETED.AFTER THE DIALING IS ®LES SCHWAB 20 AMP Y DEDICATED OTHT R(L VAC f RT TEST REMOTE TEST STATION TEST 4-#1 BAWG SS000672 (B OTHERS) COMLETED,THE DIALER CAPTURE MODULE RETURNS A HANDSHAKE TO THE FIREP PANEL.THE FIRE PANEL THEN SENDS THE CONTACT ID REPORTS TO THE DEDICATED 120 VAC DIALER CAPTURE MODULE,WHICH IN TURN SENDS A KISS-OFF AFTER THE SH=SHIELDED 20 AMP CIRCUIT(LOCKED) REPORT IS SUCCESSFULLY RECEIVED FROM THE FIRE PANEL. THE DIALER 'WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED (BY OTHERS) CAPTURE MODULE SENDS THE CONTACT ID REPORTS TO THE COMMUNICATIONS F E SYSTEM MODULE.WHEN ALL THE REPORTS ARE SENT,THE FIRE PANEL GOES ON-HOOK. LES SCHWAB TIRE CENTER DOCUMENTATION THE COMMUNICATIONS MODULE THEN TRANSMITS THE MESSAGES TO THE s AS-BUILT DRAWINGS CENTRAL STATION. a.� 16607 SMORIN POINT BLVD. Y`q R A ARLINGTON,WA 98223. Y` DESIGNED BY: P.ROJAS DRAWN BY: P.ROJAS 5 CHECKED BY: 04/25/2025 S� JOB/CASE#: 1-91ZJWV1 EE SHOP DRAWINGS RISER DIAGRAM NOTE DEVICE WIRING SHOWN IS CONCEPTUAL.POINT TO POINT CONNECTIONS MAY VARY.REFER TO FLOOR PLANS FOR REQUIRED EQUIPMENT LOCATIONS.THE ELECTRICAL CONTRACTOR SHALL REFERENCE EQUIPMENT "- INSTALLATION DOCUMENTS,DRAWING TERMINATION DETAILS,AND RISER DIAGRAM FOR COMPLETE EQUIPMENT INSTALLATION. SHEET: SHOULD ANY CONFLICT ARISE BETWEEN DESIGNED PLANS,BATTERY CALCULATIONS,VOLTAGE DROPS,AND ACTUAL INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF JCI IN WRITING UPON DISCOVERY AND PRIOR TO ELECTRICAL ROUGH. RISER DIAGRAM Ft �e B CALCULATIONS RISER DIAGRAM o� s$ o� FA201 �a 1• •I• •1• •1 30"X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/8/2026 1:36:51 PM LAST SAVED BY:JARAIZM FILE PATH:C:\Users\jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_Arlington_WA_FA_DD01_1-91ZJWV1-REWORKED.dwg o o c. FIRE RATED CONCRETE BLOCKWALL FIRE RATED GPY. WALLBOARD FIRE RATED GPY. WALLBOARD CEILING TO WALL TRANSITION AND OPEN WIRING �� �I C-AJ-1045 W-L-1001 W-L-3149 Johnson CONDUIT PENETRATION U.L.C-AJ-1045 Controls CONDUIT PENETRATION U.L.W-L-1001 GLOBAL JOHNSON CONTROLS 1 OR 2 HOUR RATED CONCRETE BLOCK WALL ASSEMBLY 3M FIRE BARRIER CP 25WB+CAULK OR EQUAL 1 OR 2 HOUR RATED GYP. 3M FIRE BARRIER 142E EXPOSITION AVE#1AR OF NCE WALLBOARD ASSEMBLY CP 25WB+CAULK OR EQUAL CABLE PENETRATION U.L.W-L-3149 AURORA,CO 80012 1-877-330-7404 1 OR 2 HOUR RATED GYP, WALLBOARD ASSEMBLY 3M FIRE BARRIER CP ZSWB+CAULK OR EQUAL 71 PACKING MATERIAL CABLE OR ' CONDUIT CABLE BUNDLE CENTER OF EXCELLENCE NETWORK FIRE ALARM WIRE NOTES: NOTES: NOTES: 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 0 CONDUIT SHALL BE INSTALLED AT CENTER OF STUD CAVITY WIDTH AND 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. CONDUIT KEY 1 PLAN: 2 THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2 THE ANNULAR SPACE BETWEEN CABLE/CABLE BUNDLE AND PERIPHERY OF OPENING SHALL BE BE 0 TO 1-3/8" 0 TO 1". CAULK FILL MATERIAL SHALL COMPLETELY FILL ANNULAR SPACE px 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. BETWEEN CONDUIT AND WALL;AND WITH A WIDTH OF 1/4"DIAMETER 3 MAXIMUM OF V DIAMETER CABLE BUNDLE PER FIRESTOP SYSTEM. PACKING MATERIAL-MINIMUM 4"THICKNESS OF MINIMUM 8 PCF MINERAL 2 BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS OF CAULK MATERIAL-MINIMUM 5/8"THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, THE WALL. FOR CONDUIT 1"DIAMETER AND SMALLER,ANNULAR SPACE 4 FLUSH WITH BOTH SURFACES OF THE WALL.MINIMUM 1/2"DIAMETER BEAD OF CAULK APPLIED WOOL BATT INSULATION SHALL BE FIRMLY PACKED INTO OPENING AS A SHALL BE O TO 3/16". FOR CONDUIT 4"DIAMETER AND SMALLER, AT THE CABLE/WALLBOARD INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. NOTES" 4 PERMANENT FORM. PACKING MATERIAL SHALL BE RECESSED FROM BOTH ANNULAR OF(1)CONDUIT PER FIRE TOP SYSTEM.SPACE SHALL BE 0 TO 1-1/2". 5 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. THICKNESS OF CAULK MATERIAL. 3 M SURFACES OF WALLAS REQUIRED TO ACCOMMODATE THE REQUIRED 1 CONDUIT SHALL BE USED FOR ALL EXPOSED FIRE ALARM CABLING INSTALLED BELOW JOISTS AND BEAMS. 5 CAULK MATERIAL-MINIMUM 1/2"THICKNESS OF FILL MATERIAL SHALL BE 4 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. 2 CONDUIT SHALL BE A MINIMUM OF 3/4". APPLIED WITHIN THE ANNULUS,FLUSH WITH BOTH SURFACES OF THE WALL. CONTACT INFORMATION: DEVICE MOUNTING HEIGHTS POWER DISCONNECT DROP CEILING Et J BOX PHONE CONNECTION DEVICE MOUNTING HEIGHT REFERENCE(PER NFPA 72) II M x ce sm"ii.o°cw'wsnErz D0M11 DMARC JVL U u IV�oAe xPPy uuwPansxno LINE I- RJ 31X BLOCK nRE aLaRM PANEL FlaE atARM PANEL RED GREEN BLACK a mw eaow Nuisx YELLOW 6 RI CORD RI 31X BLOCK �xevis -la�Y:� °PE LINE TO PHONES n0u i�aLTM�M,tiE CEluue � romT000xeo•wix ILIs-JI x acme � � O o RED GREEN � w<A rv�P+T� ocTAcoN JUN T'.sax TELCO LINE 9 0 L. xNAll—El"'Cx s 1 } au xnn Txax TaPnxovE nxlsxeo wax xElexroF O BLACK B R CORD max inu,r xn°°rrtEw ® CONDUIT \ DISTRIBUTION PANEL YELLOW OR RJ CORD FIRE&AW CONTROL PANEL 3eiexxEx�.P,.eaxlxaLP.xa�x xx.maRxxro IIII O IIIII $$ 0 vsxr°rxuxwx.c°mxaLvnx¢sxnu xmaEun max w'x (�J�'I CONDUN r� "' PRIMARY PORT E$ DEDIUTED LOCKE 6 CIRCUIT SRELX D g`" O WVLL FIRE ALARM DISCONNECT CO DEDIWED UO VACo30AM BRANCH E e / T�cunm ewe­1 —1 uc CIRCUIT PRIMARY PORT SECONDARY PORT HEAT DETECTUR z m oc -ExR.1TU wug—Ruc BURGLAR PANEL 8 E O00 FIRE ALARM PANEL 40TEG'. SQUARE aFTHEcauxc HacUTa.i x, JUNCTION Box EGI E5 s" PETEETgxssx"DULgurz°gxmE CELxa `"` �a DEVICE WIRING STROBE — HORN/STROBE DEVICE WIRING AUDIBLE DEVICE WIRING OS&Y TAMPER SWITCH GATE VALVE WATERFLOW Et BUTTERFLY TAMPER SWITCHES 1/P CONDUIT eC u€ "E! cove Tsxnzx wrEwlsEP FLOWSWITCH u£ / IPszn,[uuxaT°x°x z9Nlvu[xrl $= BREAK WIRE I/ s" DO NOT LOOP ""`°`°"" 1/2 WP FLEX CONDOM Ba BREAK WIRE w FIRE RATED DO NOT LOOP ax 1. SPRINKLER RISER v CABLE STROBE STROBE/HORN + w" O O S T OR EOL _ O O 45 BOX W/COVER PRECEDING HORN O O s ,�, '-"0 CONDUIT +z '-"0 RESISTOR + - + OR POWER SUPPLY NEXT HORN OR EOL °? AT LAST FIRE RATED CABLE q B3 03 DEVICE OR CONDUIT PRECEDING _ EOL BREAK WIRE o / FROM STROBE DO NOT LOOP p BUTTERFLY TAMPER SNITCH RESISTOR LAST ors. w"PxvlEm / e` DEVICE OR POWER AT LAST + _ vrwPFLrxcoNDulr e SUPPLY DEVICE T; PRECEDING STROBE ISSUE LOG: �= axNalxcaxaan ��NxEmPW axxN�a�awaa s= OR POWER SUPPLY NEXT STROBE OR EOL gE :<xo,a�wPW axN��a Eanwa +r=e WALL NOTES: EgALL 5Y5 9� �o 9 FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION HEAT DETECTOR CELL-CAB-FL HONEYWELL HWF2-COM TELGUARD TG-7FS 5601 P i5 A=31/2-Cetagonalbm - - 9; B=4"Octagonal box - - ED C=Single gang toz and 4"square with plaster Nng g SO dmE ANTENNA BMx +) Bozaxxebp REMOTE D=Directly to Wall/Ceiling SURFACE-MOUNT 5 ANTENNA ANTE PIER �• INCOMING O 5` TELCO p INS PLATE A c SCHWAB nu A u PHONE p `l�.J, ®�J�V SCHW�B BATTERY WIRING 3 SHOULD BEAT LEAST (D © B CT :sa 1/4"APART FROM AC O _ WIRES By gE '"'°'"'�'"- TELGUARD �' LES SCHWAB TIRE CENTER s O ® ua r DIGITALTG-7FS Oa dA FLUSH40UM O BATTERV /1 a5 gFaBri agBaFala; .a, ❑ W C 0 So o LOOKwAaHERAND NUT °eves° �_ ❑ �— e e o R 0 �• o DD .w°U wTTaiO ALARM PANEL A ® SIM Wlring Dlagrem-Single Clrcglt Motlels: 16607 SMOKEY POINT BLVD. Y` O .no R - _ + ARLINGTON,WA 98223. .g.Rp�y O + ! STC2 e •e� $ STC1) TAMPER a (� (, i z ' o Control Auxiliary DESIGNED BV: P.ROJAS E IPOTs-com �18 wa4❑ (N.O.) SWITCH o Panel EOL OR Device lit-JJJBB fl o� BATTERY DRAWN BY. P.ROJAS 5 TO BACKeox d¢gg CONNECTOR H _ CHECKED BY: 04/25/2025 ;5 o EARTH GROUND Rim ,- we JOB/CASE#: 1-91ZJMI O O O III "Bill BAIIWY a AG(12V BOOM,) WIHno Olagram-DuaICIx.RMg4"Ic: GE L�JL-,Y= BATTERY CONNECTOR 5$ - a"M°"9 TRIP INPUT + FelnBtall dDDF o o ,m,,, SHOP DRAWINGS xo Control EOL OR Auxiliary Auxiliary �B NOTE:WHEN USING THIS SCHEME,THE USE OF THE PRIMARY OR SECONDARY DIALER TO Panel Auzlllary Auxiliary Device Device e NOTE:THE CELL-MOD(C)/CELL-CAB-FL OFFERS AN OPTIONAL GSM COMMUNICATOR CARD FOR CENTRAL STATION REPORTING.IT MOUNTS CONNECT TO TELCO IS WHAT DETERMINES WHETHER THE TG-71S MEANT TO WORK AS A Device Device SHEET: IN ITS OWN PLASTIC ORMETAL ENCLOSURE.USE OF THE CELL-MOD(C)/CELL-CAB-FL REQUIRES THE IPOTS-COM COMMUNICATOR. RACK-UP OR PRIMARY COMMUNICATOR. - USE EITHER AC POWER(FROM ADAPTER)WITH BATTERY OR USE DC POWER(FROM PANEL). 5E PRODUCT TYPICALS �6 A PRODUCT TYPICALS o� a H FA301 is I •I. I •I IT X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:1/B/2026 1:36:55 PM LAST SAVED BY:JARAIZM FILE PATH:C:\US111jaraizm\OneDrive-Johnson Controls\Desktop\hhh\LSTC_Arlington_WA_FA_DD01_1.91 ZJWV1-REWORKED.dwg 5t FIRE ALARM NOTES Johnson Controls 1. ALL APPLICABLE CODES SHALL BE OBTAINED PRIOR TO START OF WORK 2, THE SYSTEM SHALL BE LOW VOLTAGE,PROTECTED PREMISES FIRE ALARM/CENTRAL STATION SERVICE,ALARM SIGNALS SHALL BE RECEIVED AT JCI'S CENTRAL JOHNSON CONTROLS S STATION AT: GLOBAL CENTER OF EXCELLENCE 142M E EXPOSITION AVE YtA 14200 E.EXPOSITION AVE. " AURORA,co 80012 k,''" AURORA,COLORADO 80012 ' J-877-330-7404 3. ALL FIRE ALARM DEVICES ARE TO BE INSTALLED ACCORDING TO THE REQUIREMENTS OF NFPA72 AND THE MANUFACTURES INSTRUCTIONS. 4. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 5. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN UP OF ALL TRADES IS COMPLETE AND FINAL. 6. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 10%.(SEE CALCULATIONS). 3` 7. ALL FIRE ALARM DEVICES ARE TO BE U.L LISTED AND COMPATIBLE. - 8. ALL WIRE IS TO BE IN CONDUIT FROM DEVICE BACK BOX TO ABOVE FALSE CEILING OR TO THE BAR JOIST.WIRE MAY RUN EXPOSED HORIZONTALLY,BUT MUST BE _•; - I. :. ` .. EXCELLENCE NENJORK SUPPORTED PER NFPA 70 REQUIREMENTS. - 3 ana onal -a i .m,vskav I' . € le.9uiatr 9. ALL WIRE SHALL BE POWER LIMITED,FPLP UNLESS OTHERWISE NOTED. 10. WIRE ROUTING SHOWN 15 DIAGRAMMATICAL AND DOES NOT REPRESENT ACTUAL RUNS.WIRE LAYOUT IS SUBJECT TO CHANGE AS NEEDED BY THE INSTALLING CONTRACTOR. CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP CALCULATIONS OR PANELS MAXIMUM SIGNAL LINE CIRCUIT ." KEYRnN. CAPABILITIES. 11. UNLESS OTHERWISE REQUIRED BY AHJ;ANNUNCIATOR/KEYPADS TO BE MOUNTED AT 54"ABOVE THE FINISHED FLOOR TO THE TOP OF THE UNIT, LES SCHWAB TIRE CENTER 12. MANUAL PULL STATIONS SHALL BE INSTALLED WITH THE OPERATIONAL PORTION 42-48 INCHES ABOVE FINISHED FLOOR. F __ 13. ALL VISUAL DEVICES SHALL HAVE THE CANDELA SET PER APPROVED PRINTS.CANDELA VALUE NOTED NEAR THE DEVICE ON DRAWINGS. 14. CEILING MOUNTED NOTIFICATION DEVICES ARE NOTED WITH A"C". # - v Les Bohrr L 15. DESIGN IS BASED ON:CONTRACT DRAWINGS,ENGINEERED PROVIDED PLANS,SITE SURVEY.ALL EQUIPMENT IN THIS DESIGN SHALL BE INSTALLED PER ITS LISTED ?OD;iiml DIBs ,StrJDen NPrAB- '*, USE. 16607 SMOKEY POINT BLVD.16. DEVICE LOCATIONS ARE BASED UPON APPLICABLE CODE,MANUFACTURES INSTALLATION INSTRUCTIONS,AND ACCEPTED INSTALLATION PRACTICES.SHOULD ANY - 1 e -1s r1e=s; �.L _ CONTACT INFORMATION: UNKNOWN CONDITION BE DISCOVERED DURING INSTALLATION WHICH CONFLICTS WITH APPLICABLE CODE,IT SHALL BE BROUGHT TO THE ATTENTION JCI IN w •.... WRITING PRIOR TO INSTALLATION. ARLINGTON, WA 98223. 17. THE TOTAL SOUND PRESSURE LEVEL PRODUCED BY COMBINING THE AMBIENT SOUND PRESSURE LEVEL WITH ALL AUDIBLE NOTIFICATION APPLIANCES OPERATING - v, SHALL NOT EXCEED 110 DBA AT THE MINIMUM HEARING DISTANCE. - ,s`MeryS mkT6yeta 18, A FIRE ALARM SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 DBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS. - `i,A .. Farar41S8i II FOTd SHEET INDEX gsaE Waoda e c " SHEET DESCRIPTION 1;1 VICINITY MAP I SCALE:NT S ABBREVIATIONS IN INCHES FA000 COVER SHEET SYMB DESCRIPTION KW KILOWATT FA101 DEVICE PLACEMENT PLAN LVL LEVEL FA201 RISER DIAGRAM&CALCULATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUM AEG ABOVE FINISHED GRADE MIN MINIMUM FA301 PRODUCT TYPICALS �--4 AMP AMPERE MNS MASS NOTIFICATION SYSTEM GIBBENS DRAKE SCOTT,INC sane.es,�-aeaa,sores lao BA owN,>nlsso:sal wm AUX AUXILIARY MTD MOUNTED AWG AMERICAN WIRE GAUGE N4 NEMA4-NON CORROSION-PROOF y ENCLOSURE 8 BEG BELOW FINISH GRADE NEMA4-CORROSION-PROOF g. N4X ENCLOSURE t BLDG BUILDING N12 NEMA 12 SEALED ENCLOSURE C CEILING MOUNTED NAC NOTIFICATION APPLIANCE CIRCUIT CIRC CIRCUIT # NUMBER SCOPE OF WORK sg PNL PANEL NEW FIRE ALARM SYSTEM. .a '�53isy C PH PHASE CONO CONDUIT THE NEW SYSTEM SHALL INCLUDE: 'PO kFT'I%1EpS G. k ON DOWN PS POWER SUPPLY • AN ADDRESSABLE FIRE ALARM CONTROL UNIT. ak DWG DRAWING QTY QUANITITY AN EXTERNAL FIRE ALARM CELLULAR COMMUNICATOR IS TO BE INSTALLED BY THE CONTROL UNIT. SEC SECONDARY • A DOCUMENT 60%IS TO BE INSTALLED BY THE CONTROL UNIT. DEGREE SLC SIGNAL LINE CIRCUIT A FIRE ALARM ANNUNCIATOR IS TO BE INSTALLED AT THE FRONT ENTRANCE AND AT THE EXIT OF THE SPRINKLER ROOM. if° • A SMOKE DETECTOR IS TO BE INSTALLED ABOVE THE CONTROL UNIT AND REMOTE NAC BOOSTER POWER SUPPLIES,AND AT ELEC ELECTRICAL TEMP TEMPERATURE� THE ELECTRICAL ROOM.� EXT EXTERIOR MANUAL PULL STATIONS ARE TO BE INSTALLED WITHIN 5 OF EGRESS DOORS. TYP TYPICAL • HORN/ST0.0BES ARE TO BE INSTALLED THROUGHOUT THE FACILITY. �$ EX EXISTING DEVICE V VOLTAGE STROBES ARE TO BE INSTALLED IN SMALL ROOMS AND BATHROOMS THROUGHOUT THE FACILITY. t? A WEATHER-PROOF HORN/STROBE SHALL BE INSTALLED OUTDOORS NEXT TO THE SPRINKLER ROOM. EQUIP EQUIPMENT VAC VOLTAGE ALTERNATING CURRENT • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE SPRINKLER WATER-FLOW SWITCHES. S XP EXPLOSION PROOF W WATTS • MONITORING MODULES SHALL BE PROVIDED TO SUPERVISE THE FIRE PUMP SYSTEM. FIRE ALARM SYMBOLS L' I WP I WEATHERPROOF • 120VAC SURGE SLJPPRE55ORS SHALL BE PROVIDED TO PROTECT AC CIRCUITS USED FOR FIRE ALARM EQUIPMENT. FA FIRE ALARM • MONITOR MODULES SHALL BE PROVIDED FOR SUPERVISION OF THE EXISTING DUCT DETECTORS. FL FLOOR LNG WIRE GUARD QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX -�� WE WIRELESS DEVICE FT FEET THE NEW FIRE ALARM SYSTEM SHALL MONITOR AND CONTROL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES. 8 GND GROUND WI WITH 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN THE NEW FIRE ALARM SYSTEM SHALL ALSO MONITOR THE FIRE PUMP SYSTEM,SPRINKLER SYSTEM B EXISTING DUCT DETECTORS. THE NEW FIRE ALARM SYSTEM SHALL COMMUNICATE TO THE MONITORING STATION VIA THE NEW EXTERNAL SOLE PATH FIRE 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN ALARM CELLULAR COMMUNICATOR. g THE BUILDING IS FULLY SPRINKLERED. 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R s� BEFORE INSTALLATION OF ANY SYSTEM COMPONENT,THE INSTALLATION TECHNICIANS SHALL CONFER AND COORDINATE WITH THE GENERAL CONTRACTOR AND ALL OTHER APPLICABLE TRADES TO ENSURE THE INSTALLATION LOCATION WILL NOT CONFLICT WITH OTHER TRADES. 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN gb ALL WIRE SHALL BE OPEN-RAN OR CONCEALED IN THE WALLS OR CEILINGS.WHERE THE WIRE IS BELOW 10',IT SHALL BE INSTALLED IN W'EMT CONDUIT. R"g 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN § UPON AHJ'S ACCEPTANCE OF THE NEW SYSTEM,THE EXISTING SYSTEM SHALL BE REMOVED. 2 OS P SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQ x 2.5"D s" 7 ❑F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG E� ISSUE LOG: �� MUM DATE INT OESCRIMION 4 - B ADA ADDRESSABLE INPUT MODULE FIRELITE MMF-300 V SQ x 2.5"U DPo�ansrzs PRo aaroosm uvour ;i soos 7issas xAD sIwF PPAwImc i� FIRE ALARM MATRDI I SEQUENCE OF OPERATION 2 aI D DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 V SQ x 2.5"D SYSTEM OUTPUTS e, 1 ®to ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300.10 4"SQx 2.5"D F z O 5 ~ a O 2 ® ADDRESSABLE OUTPUT MODULE FIRELITE CRF-300 4"SQ x 2.5"D sa a Ei O CODE ANALYSIS O z 0 BUILDING OCCUPANCY TYPE M,B,S-1 o m ? 0 8 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ x 2.5"D p NUMBER OF STORIES TWO(2) o 1. z z z qq O $ PROJECT AREA 16 404 SQ.FT. 8 p ' 0 0 1= 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQ x 2.5"D w c$ TYPE OF SYSTEM ADDRESSABLE INITIATION B CONVENTIONAL NOTIFICATION m a 4a z m z C LISTING AGENCIES(UL,FM,MEA,ULC) UL 964 J as o w Y m 0'. w 0 F X j u 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D WIRING TYPES OPEN CEILING,CONDUIT I�'F ; S 4 ✓i O ,o a z z v, a z '= u � zw w TYPE OF COMMUNICATION REMOTE STATION w O a p g O I- F O t§ ¢ Z5z r- i N i E z a z o y a m g 1 HORN/STROBE•WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED Y AUDIBLE NOTIFICATION TEMPORAL3 9 z dq z q¢ a ¢� w 0 w a z WP g n VISUAL NOTIFICATION PUBLIC MODE o N E m O O O m 0 m o I N a g 0 Z o g= a z m r a I= rc z E w z > rc z a rc z 2 0 rc z 1 SS SURGE SUPPRESSOR DITEK DTK•120HW OWN BUILDING SPRINKLER SYSTEM FULLY SPRINKLERED D g ❑ I_ w z 0 z O 0 0. 0 0 zo 0 0 0 � o_ )8 F H O F V , 4J a 2 0 u I STANDARDS- NFPA 72(2019),NFPA 70(2017) ? O F S Z5 ti u F 5 LC F u F N ¢ r t LES SCHWAB TIRE CENTER D' I' Z W a 2 2 N 2 Z UJ 6 2 y M Z UJ Z O Z o Z B, 0 M M a . w > o > o a a w 2 S SMOKE DETECTOR-DUCT EXISTING APPLICABLE CODES IBC(2018),IFC(2018),IMC(2018)ASME/ANSI A117.1(2017) 0 s O , m z C7 O o z G O Z ¢ z o w O E- < z ;j z z z & z z z w 'ni` w w a w z z -' z > a arc a s rq a ft ti < Er F Z LL > gs < m o w F o w s w g z a F m 0 a o a 00 a 4 C, a o < 0 � a > j 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING D' �J O W N O G w O C J w O U d' O w O w U �' 0 O 0 0 16607 SMOKEY POINT BLVD. $ SYSTEM INPUTS c0 o z m > cT a a m 1- a m F a m t- a m 1- If a '� a 2 ¢ a CONTROL UNIT FUNCTIONS 1 KB KNOX BOX EXISTING ARLINGTON,WA 98223. g� SYSTEM RESET(ONE S_YS_TEM_S_NORM4L" X _ 2 �; �_ SYSTEM SILENCE X X� .._......_,..,......__»._.._..-... ._ .». ._._ ._.. - --. � FLOW DETECTOR/SWITCH EXISTING ONE POINT FOR RESET) _ X X � � DESIGNED BY: P.ROJAS DRAWN BY. P.ROJAS s DRAWING ACCEPTANCE ALARM DEVICES THIS DRAWING IS TO BE USED ONLY FOR THE PURPOSE OF PLACING AND LOCATING JOHNSON CONTROLSE EQUIPMENT AND IS NOT TO ___ WATERFLOW SWITCHES _ _ X _ _X X %_ X __ o MANUAL PULL STATIONS % ,__ _ X X x_ _X __ 1 HP HIGH AIR PRESSURE SWITCH EXISTING JOB r EASE x: 1-9lzlwvl BE USED FOR ANY OTHER PURPOSES.IT IS THE RESPONSIBILITY OF THE LOCAL JOHN50N CONTROLS SALES&SERVICE OFFICE(550) - _._....__.. .._. .,-.._..._..._.._........._._......_. .- ._.. _- _-. ... ......_- _...... ..... ..... TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO SMOKE DETECTORS % X X % X = RELEASING THEM TO THE FIELD. SUPERVISORY DEVICES Ep SPRINKLER TAMPER SWITCHES x x x 1 LP LOW AIR PRESSURE SWITCH EXISTING g RECORD DRAWINGS `""JIRPRESSURESV4TCHEs` ._.-�. z_. ❑ SHOP DRAWINGS "o ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE JOHNSON I(NOX BOX TAMPER SWITCH _ � % X X & CONTROLS OFFICE AT THE ADDRESS LISTED ABOVE. -DUCT SMOKE DETECTORS % % X % .S a 1 VALVE-GENERAL EXISTING s R MONITORING LOCATIONS TROUBLE FUNCTIONS SHEET. P1 OSS OF DIALTONE OR CELL DIALER C0 ECT X X X ».. JOHNSON CONTROLS ALARM SERVICE CO:144525 _ sy 14200 EXPOSITION AVE. uL USnNG:599aa e3 _FIRE ALARnn sysrEMAC PowER FAILIP _,. _ _.__ __ x_ X _- 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING # AURORA,CO.80012 FIRE ALARM SYSTEM LOW BATTE X_ % _ _ % �- --+ COVER SHEET _ _-_ 7-800.428.7124 - ABNORMAL CIRCUIT OR X % X YX sg 3 ORDER OF OPERATION /1 DEVICE LEGEND n FA000 1 •I•• 1 ••1• 1 30"X 42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:07 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_Arlington_WA_FA-DD01_1-91 ZJWVI.dwg FIRE ALARM SYMBOLS ,OI1nSOn 60 l� CITY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX Controls North County RFA JOHNSON CONTROLS 1 FAN 1 FIRE ALARM CONTROL UNIT FIRELITE ES-200X OWN EIAP PROVED PPRO\/ED GLOBAL CENTER OF EXCELLENCE Y 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWN 142M E EXPOSITION AVE AA ❑APPROVED AS CORRECTED AURORA,CO W12 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE MN-80 ANN-SB8OKIT-R 1-877-330-7404 ❑ REVISE AND RESUBMIT 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN ❑ REJECTED 1 DOL FIRE ALARM DOCUMENT BOX SPACE AGE SSUG0672 OWN ❑ FOR INFORMATION ONLY 2 Qp SMOKE DEFECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.51) is CENTER OF E%CELLENCE NETWORK 7 �F FIRE ALARM PULLSTATION FIRELITE BG-12LX 1 GANG 8 Ana ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx 2.5"D Subject To Field Review KEYPLAN: ><M223 E FIR 2 AIMD DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4'SQx2.S"D M /I M21 PUMP UM I�tA P! 1 AIM 10 ADDRESSABLE INPUT MODULE-10 INPUTS FIRELITE MMF-300-10 4'SQx 251) �M20 1 / 7 MM 10�M1B i ^ BY sgoforth DATE 9/8/2025 2 0® ADDRESSABLE OUTPUT MODULE FIRELITE CRF-300 4"SQz2.5"D M17 o I� ¢ ><M16 Mil IM~ * a 6 STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED 4"SQ z 2 51) �M15 5 M14�r ♦ t 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLE0 4"SQx 2.5"D M13 � c coNracT INFORMATION:INFORMATION:EOL _ A 9 1 M 8_ 6 — — _...- / 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D / 110 Pr_ / _ i HORN/STROBE-WALLMOUNT-WEATHERPROOF SYSTEM SENSOR P1RK INCLUDED FACU FAC NAC DO SS AA F 24 A 7 FAA / F A � WP 1 AI AIM C5 �-C1. D I�I _ /� C10 C70 I 1 55 SURGE SUPPRESSOR DITEK DTK-120HW OWN 3 2 -✓ 'o ¢ > SPRINKLER ROOM 2 �5 SMOKE DETECTOR-DUCT EXISTING MECH.RM. TO FACU a C TO FACU ROOM S D02 TO FACU - ¢ 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING CEILING OVER SHOWROOM IS _ _.� a 75 CD 1 KB KNOX BOX EXISTING BELOW _ ALIGMENT BAYS A A s a _ PARTS 2 r R, FLOW DETECTOR/SWITCH EXISTING "V� STORAGE RM. o SHOWROOM �� �� 1 HP HIGH AIR PRESSURE SWITCH EXISTING �GffiHHNB DRAKE SCOT'F,INC 9x'nrro6azm",�me�i sdiii� ALIGMENT FIT ��1yyy¢ MGR'S � 1 LP LOW AIR PRESSURE SWITCH EXISTING � ¢ OFFICE - ¢ 11 VALVE-GENERAL EXISTING STAIRS TC10t l y SIAMESE FIRE DEPARTMENT CONNECTION EXISTING +a 5A22 kFST£Y'4,14 P HALL �'SS10uALY`G a5 TO FACU ! - PARTS ROOM GENERAL NOTE 3s a 1)ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. TL L OEVEN FROM 2N a REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. 2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT F M03 LEVEL - LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP g - i ¢ CALCULATIONS. g 95 CD a 115 CD ¢ 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD =f VERIFIED. —L C 4)ALL FRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 RTU#1 _ � M30 F (NATIONAL ELECTRIC CODE). i 11 MA5 D—S——RT RTS TO FACU -�-C7- 55)WHERE CONDUCT IS REQUIRED,MINIMUM SIZE SHALL BE 314". )ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE PATH. 1 WAREHOUSE 150 CD 3 135 CD 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE C7—C7—C7 C7 C7 C7 C7 C7 C7 ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. q` —a —¢ ���CCC CABLES TURNS SHALL BE ROUTED AT 90 DEG.ANGLES TO THE BUILDING.NO RTU#2 WAREHOUSE UNLOADING DIAGONAL RUNS ARE PERMITTED. eSALES AREA t7 4 M06 S ¢ 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. 1 — RTr u �A: a - �91 CD 0 FLAG NOTES LOCKER RM. u SERVICE ROOM ¢ NEW FIRE ALARM CONTROL UNIT SHALL BE CONNECTED TO DEDICATED eX' WOMEN 120 VAC POWER,LABEL CKT BREAKER"FIRE ALARM". 59 F 2 FIRE ALARM CONTROL UNIT SHALL COMMUNICATE TO MONITORING 8 I O STATION VIA SOLE PATH CELLULAR COMMUNICATION. TO FACU O MONITOR MODULE FOR FIRE ALARM CELL DIALER COMMUNICATOR TROUBLE SUPERVISION. k RESTItM. tSMEN a HP MONITOR MODULE FOR NAC POWER SUPPLY TROUBLE SUPERVISION. B a 0 CD 1 LP 0M27 DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF WATERFLOW ISSUE LOG: .� SWITCH. EOL C9 INSTALL EXTERIOR HORN STROBE NEXT TO THE SPRINKLER ROOM, 000+a ms PR m—I.ur pp f a —C9—C9 C9 C9 C9 C9 C9 som n Ao zl+oP ow+ww, 5� O7 10 MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVES. $ 115 CD M2 F 5 I ¢ C 0MONITOR MODULE INSTALLED FOR SUPERVISION OF GATE VALVE. _� EOL m 75 CD O MONITOR MODULE INSTALLED FOR SUPERVISION OF FIRE PUMP. SALES AREA a DUAL MONITOR MODULE INSTALLED FOR SUPERVISION OF HI/LOW AIR Y 2 N D LEVEL CUSTOMER SERVICE BAYS a 1 PRESSURE SWITCH AT THE DRY SYSTEM RISER. ag O MONITOR MODULE FOR SUPERVISION OF EXISTING DUCT DETECTORS. � LOUNGE 71 FIELD VERIFY LOCATION. ¢ QADDRESSABLE RELAY MODULE FOR HVAC SHUTDOWN,FIELD VERIFY LOCATION. og I s"i a A-AA AA �-AAAAA-A-A-A-A-A-A� FROM � - FACU €,x AD �75 CD � M25 F FAA L9,9-0-0-0-C9 EOL WB WIRE CHART CIIRRCPET ANDI ITYPE OFI IWIRE -�'�.••�.____ MAIN LEVEL SYMBOL CIRCUIT DESCRIPTION 's€ A slc 2-#iBAWG LES SCHWAB TIRE CENTER SIGNALING LINE CIRCUIT (POWER LIMITED) AD ANN (BLKANN/II RD-DA A)ATOR BUS 4-#1BAWG (WHT/GRN=PWR) 25 C TRIP NOTIFICATION APPLIANCE TRIP CRT. 2-#14AWG D IDC (COMBINED HORN @ VISUAL CIRCUIT) 2#1BAWG INITIATING DEVICE CIRCUIT /6607 SMOKE Y POINT BLVD. g P (NON-INTELLIGENT DEVICES) ARLINGTON,WA 98223. t"$ P POWER 24V NON-RESE TASLE POWER 2414AWG DESIGNED BY: P.ROJAS RT TEST REMOTE TEST STATION TEST 4-#18AWG DRAWN BY: P.ROJAS �8 CHECKED BY: 04/25/2025 *WIRE MUST BE SHIELDED AS INDICATED TW-TWISTED�F OR CASE 1-91ZJWV1 gb i� SHEET'. 5e `o$ A DEVICE PLACEMENT PLAN DEVICE PLACEMENT PLAN a� N ° 4 B' 16, FA101 I•."I..•I•..I..•I 30'X 42"-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:10 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_ArtingtDILWA_FA-DD01 1-91ZJWV1.dwg FRCP BATTERY CALCULATIONS j Total Total Qry Part# Dsacnpdon Standby Ajar. Standby Ajar. CIRCUIT LOAD$VOLTAGE DROP CALCULATIONS Jo nson I' 1 ES-200X Fire Al Pa 0.14100 0.25700 0.1410 0.2$ Source: NAG#1 Controls 1 PWRM0024 OpliO 124 13Am T f (inside. panel) 0.00700 0.00800 O.W70 0. Circuit Number: 1 IPOTS-COM POTS i(tPIde the panel) 0.04000 0.0410G 0.0400 (i Device Description Standby Alarm C5 C6 C7 CS C9 C70 1 ANN-80 Remote Annunciefor 0.01500 0.04000 0.01W 0. JOHNSON CONTROLS 2 S0365 Phslcelecblc Smoke D-tor MOOOSD OAo450 10004 0,009C SRLED WALL MOUNT STROBE RED(15 od) 0.00000 0.01800 0 0 1 0,018 2 0.036 0 0 0 D 0 0 GLOBAL CENTER OF EXCELLENCE u 7 BG-12LX Menu lP llSmeon D.00IAB G.005G0 0.0028 0. SRLED WALL MOUNT STROBE RED(30 cd) _- _ _ _ 000000 002200 0 0 0_ -O 1 0,022 1 0.022 1 0.022 0 0 14200 E EXPOSITION AVE#1A __ __._______________________ .__...__._._.__. ..._..___ _____..-_._ _____.__. _ ___ _ _____... .._...___ ___.__.... FIRE ALARM SYMBOLS 8 MMF.300 Writor Module with LED(Full Sire) - O.WIX?6 05MO-0 Ota 0. BREED________ WALL MOUNT STROBE RED(75 Ed) 000000 007000 0 0 0 0 O 0 1 0.07 1 0.07 0 0 AURORA,CO 80012 '.. _ _____- ________. _____.___------------------- _...___ _......._ __.. ._. _.._..._.__----------0 0 0 0 0 D 0 0 0 0 QTY SYMB DESCRIPTION MANUFACTURER MODEL BACKBOX 1-877-330-740a 1 M.F-30D-10 Ten-hpa Not NDodue ___ 0.00035 0.00550 1,1111 PCZRLED CEILING MOUNT STROBE RED 0.00000 0.12aD0 0 0 0 0 O 0 0 0 0 0 2 0.24 SPARE 1 FL-PS10 .. NAC 13oosto,Power supply(Trggor Cuneaj u.oODm 0.00200 0.0000 ¢ PC2RLED CELING MOUNT HORN STROBE RED(150 ed) 0.00000 0.18900 0 0 0 0 1 0.189 0 0 0 0 0 0 1 FACU FIRE ALARM CONTROL UNIT FIRELITE ES-20OX OWN P2RLE0 WALL MOUNT HORN STROBE RED(75 cd) 000000 0.087tp 0 0 0 0 0 0 1 0087 0 -- 1 0.087SMntltry Current Thal Hoes= 02529 %24 = 6. P2RLE0 WALL MOUNT HORN STROBE RED(95 d) OOOWO 009200 0 0 2 0184 0 0 0 0 1 0.092 O 0 (H.Pre P2RLEO WALLMOUNT HORN STROBE RED(135 cd) 000000 _ 018900 0 0 0__ 0 1 0189 0 0 0 0 0 0 1 NAC NAC BOOSTER POWER SUPPLY FIRELITE HPF-PS10 OWNis Alum Current Total Mnua,= 0.5603 X 083 0.0 P2R WALL MOUNT HORN STROBE RED(110 cd) 0.00000 0.21200 1 0212 0 0 0 0 0 0 0 0 0 0 (S Mna) #Devices 1 D.212 3 0.202 5 0.436 3 0.179 3 0.184 3 0.327 -C- 0 Total = 6.11 Circu@Amps 0.212 0.202 0.436 0.179 20.184 0.327 O.ODD 2 FAA FIRE ALARM ANNUNCIATOR FIRELITE ANN-80 ANN-SB80KIT-R XELLENCE NETWORK 2O%BaBerySafetywrgin 1.zzsi Circuit Length HO 100 100 250 100 l) ISO 0 Tote:Vokage Drop(14ai 0.14 0.1] 0.70 a 5 0.38 0.00 1 FAC FIRE ALARM COMMUNICATOR TELGUARD TG-7FS-V OWN Total AN Rated Batteries Needed • T.3 Total EOL Voka a 14 a 20.26 20.27 19.70 20.29 06 20.02 20.40 Total AM Rated Batteries Supplied r 12 NOTE: VOLTAGE FORMULA USED IS: 1 DOC FIRE ALARM DOCUMENT BOX SPACE AGE SS000672 OWN KEYPLAN: NAC#1 BATTERY CALCULATIONS VD=LENGTH CIRCUIT MEASURED ONE-WAY IN FT. X LOAD IN AMPERES X RESISTANCE 00316 FOR 14AWG X 2 FOR RETURN RESISTANCE)Qry Part# Description Standby Am'.warm Stdby an Alarm 2 SMOKE DETECTOR-PHOTOELECTRIC FIRELITE SD365 4"SQx 2.5"D 4 SRLED WALL MOl2JTSTROBE RED(15cd) _ 0.00000 0.01800 TeGOCOD T oa ( ) ( ) ( ) (WIRE RESISTANCE VALUES REFERENCED FROM NEC TABLE 8 2 SRLED WALL MOUNT STROBE RED(304 0.00000 0.02200 00000 0,0440 2 BRLED WALLMOLNTSTROBERED(75cd) GOOOCO (107000 0.0000 0.1400 7 ❑F FIRE ALARM PULLSTATION FIRELITE BG-12LX IGANG 1 FURLED RED 0.00000 Q08700 OOWO_ DD87_ TG-7FS-V BATTERY CALCULATIONS____ 2 PC2RLED _CEILING MOUNT HORN STROBE RED (115 d) 0.00000 ¢1Xp0 00000 0.29 Total Tatel 1 PC2RLED CEILING MOUNT HORN STROBE RED(150 d) I 0.mo0G o.1rmGG o.0000 0.�- 8 alN ADDRESSABLE INPUT MODULE FIRELITE MMF-300 4"SQx2.5"D 1 P2RLED WALL MOUNT HORNSTROSE RED(75 d) GOODDO 0.05700 0.0000 0.08 City Part Description Standby Alum Standby Alarm 3 P2RLED WALL NO,HORN STRODE RED Diii 0BOOM 0OWOO 00000 02760 1 TG7FS-V Cell Dialer Communicator 0.08300 0.23000 0.083<T 0.2300 1 P2RLE0 WALL MOINYT FERN STROBE RED(135 cdJ 0.00000 0.1e9oo 0.00Do D.1 0.0630 023DO 2 ant DUAL ADDRESSABLE INPUT MODULE FIRELITE MDF-300 4"SQx 2.5"D 1 p2i._ _____ .._ _._ _ ._..__._ _._ _ _ _ 1 P2R WPi1 MJUNR HORNSTROBE RED(110 cd) O.000W 0.2120D 0.0000 0.21 ___ .....___._ _._._..._... .._._._-__. _..___._..--------------I _________ ___._...... _.._.._-.._._.. D O.OWO 5 Standby Current Total Hours= 0.0830 X 24 = 1.9920 CONTACT INFORMATION: Standby Cu II:Taal Hours• O.0000 X24 = D.GD (Hours) 1 AIM 10 ADDRESSABLE INPUT MODULE-10INPUTS FIRELITE MMF-300.10 4"SQx 2.5"D (Fours) Alan Current Total Minutes= 0.2300 X.DB3 - 0.0191 Alarm Current Taal Mputes= 1.5380 X.083 D.1275 (5 Mine) (5 Mns) Total = 2.0111 2 ®0 ADDRESSABLE OUTPUT MODULE FIRELITE CRT300 4"SQx 2.5"p Total 0,127 '.. 20%Bedery savory Margin - = 0.02 20%Battery Safety Margin = CAM 8 � STROBE-WALL MOUNT RED SYSTEM SENSOR SRLED TSQx 2.5"D Total AN Rated Batteries Needed = D.ISW Total AH Rated Batteries Needed m 2A133 Total AI Rated ast ariee Su Ilea 7 4 HORN/STROBE-CEILING MOUNT RED SYSTEM SENSOR PC2RLED 4"SQx 2.5"D Total AH Rated Batteries supplied 7 C 5 HORN/STROBE-WALL MOUNT RED SYSTEM SENSOR P2RLED 4"SQ x 2.5"D A CALCULATIONS I WP1§ HORN/STROBE-WALL MOUNT-WEATHERPROOF SYSTEM SENSOR P2RK INCLUDED 1 SS SURGE SUPPRESSOR DITEK DTK-120HW OWN G�ffiHENS DRAKE BCOTT,INC a.s5msmrsr�su��D 2 � SMOKE DETECTOR-DUCT EXISTING CIR5 WP EOL z[o E 2 ®RTS REMOTE ALARM INDICATING AND TEST SWITCH EXISTING 8. FPLP CIR6 15 CD 95 CD 95 CD 1 KB KNOX BOX EXISTING p 14 AWG $ 2COND 2 y FLOW DETECTOR/SWITCH EXISTING 'E FPLP ° Q, Ey A 531:2 O. E E b: CIR7 15 CD 15 CD 150 CD 30 CD 135 CID �O k6C1S1'E93' is EOL - I HP HIGH AIR PRESSURE SWITCH EXISTINGfSJOy,ALy.C' 14 AWG C b= 2 LOND &€ FPO ® LOW AIR PRESSURE SWITCH EXISTING J5. ORB30CD 75CD 75CD = EOL 2 00 D 11 VALVE-GENERAL EXISTING 8 2 CON FPLP p p CIR9 95 CD 7s co oCo 1 SIAMESE FIRE DEPARTMENT CONNECTION EXISTING 14AWG EOL E 5 E 2 COND g^ FPLP CIR10 75CD 115CD 115CD PPP EOL FIRE PUMP 8§ 2COND C C C E RTU1 RTU2_�_ - FPLP DG1 MD1 M02 M03 �M04 M05 1 FM06 M0/ o02 MOB M09 MID #1 ClRii SLC LOOP A S F I I I S AD GENERAL NOTE EOL SPARE 18 AWS/2 COND,FPLP I11 ALL ADDRESSABLE DEVICES REQUIRE SLC LOOP FROM THE FACU TO OPERATE. 74 AWG P0"Ta PuuNINNG REFER TO RISER/ONE-LINE DIAGRAM FOR REFERENCE. 2 COND NO CFIANGES TO FACU EXISTING NOTIFICATION APPLIANCE CIRCUITS I S EOL I 8 EOL c5 C6 C7 CB Cs clo clo FPtP T2)WIRE RUNS ARE DIAGRAMMATIC.ACTUAL INSTALLATION MAY VARY.CIRCUIT LENGTH SHALL NOT EXCEED DISTANCES PROVIDED IN VOLTAGE DROP TO EXISTING NOTIFICATION APPLIANCES, CIR4 EOL EOL EOL CALCULATIONS. E4 D0 NOT MODIFY CIRCUIT. 1 CA I__Rom_J -R�_ L J 3)DEVICE LOCATIONS ARE APPROXIMATE,EXACT LOCATIONS SHALL BE FIELD d ONG FPLP VERIFIED. s= 4)ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED PER NEC ARTICLE 760 $ NAC#1 (NATIONAL ELECTRIC CODE). FL PSI O M26 M25 M24 M13 5)WHERE CONDUIT 15 REQUIRED,MINIMUM SIZE SHALL BE 3/4". s TO EXISTING NOTIFICATION aPPupncEs. OR3 10 6)ALL CABLES SHALL BE RUN UNEXPOSED THROUGHOUT THE ENTIRE CABLE R 00 NOT MODIFY CIRCUIT. 14 AWG PATH, 2 COND EOL 7)OPEN RUN CABLES CONCEALED ABOVE CEILING OR UNDER FLOORS SHALL BE e EOL . FPtP ROUTED UNIFORMLY AND PERPENDICULAR TO THE BUILDING STRUCTURE. BATTERY BATTERY sz1 D D MZD D role G D CABLES TURNS SHALL BE ROUTED AT 90 DEG,ANGLES TO THE BUILDING.NO g 11V 7AH 12V 7AH M2 1 m1 a + +nu� > a C< D< � M I rn I m DIAGONAL RUNS ARE PERMITTED. 2 ,CIR2. � � � � � 8)THE CIRCUIT PATHWAYS ARE DIAGRAMMATIC FOR EASE OF ILLUSTRATION. "y g DEDICATED 120 VAC TO EXISTING NOTIFlCATIONAPPUANCES. EOL EOL EOL EOL EOL EOL EOL EOL EOL EOL @= 20 NAP CIRCUIT(LOCKED) DO NOT MODIFY CIRCUIT. 14 AWG ISSUE LOG: (BY OTHERS) 2 CON D Dn/E IKI01 S•. FPIP M29 AGO M31 DDD1 Oa/a5/zs Pa POPOM uvw y5y �M-28 F F wan D D 5HOP PPAAn q• CIR1 - �M-27TO IXi5TING NmIFlCATIDN APPLIANCES.DO NOT MODIFY CIRCUIT. tq AWG y g 2 COND F FPLP ' •a WIRE CHART -cr cz c3 cq p CIRCUIT ,MIANDTYPE ONIMUMF WIRE Sli --..-- ---. --.. TYPE SYMBOL CIRCUIT DESCRIPTION - E 8 FAA SIGNALING LINE CIRCUIT - A SLC (POWER LIMITED) 2418AWG 8 m CON FIRE LITE gFPLPO \\<3`/ ANNUNCIATOR DATA BUS b ES-20OX \ AD ANN (BLK/RD=DATA) 4-#18AWG a TG-7FS-V BASIC SYSTEM FUNCTIONAL 6 TRIP CIRCUIT (WHT/GRN=PWR) t FACU u CELL OPERATION NOTIFICATION APPLIANCE TRIP CKT. MCBL-7 UNIT C TRIP 2-#14AWG e a (COMBINED HORN B VISUAL CIRCUIT) gE SS TG-7FS-V U.L.LISTED CENTRAL STA'NON WHEN A FIRE ALARM CONDITION (ALARM, SUPERVISORY OR TROUBLE) ISSCH DETECTED,THE FIRE ALARM CONTROL UNIT GOES OFF-HOOK TO DIAL THE INITIATING DEVICE CIRCUIT - H BATTERY BATTERY JOH EXPOSIIOROLS D IDC N 2-#i BAWL 14200 E EXPOSITION BLVD. CENTRAL STATION.THE DIALER CAPTURE MODULE DETECTS THE THE FIRE (ON-INTELLIGEN7 DEVICES) `c 12V 12aH 12V 12AH MCBL-7 CONDITION AND PROVIDES THE FIRE PANEL WITH A DIAL TONE WHEN THE FIRE g° ® AURORA,CO 80012 PHONE PANEL DETECTS THE DIAL TONE,IT BEGINS DIALING THE CENTRAL STATION.THE P POWER 24V NOWRESETTABLE POWER 2414AWG eR 1.800428J124 DIALER CAPTURE MODULE CONSIDERS THE THREE SECOND PERIOD AFTER "AW4my y HArf' ;< 2D AMP CIR UIT(LOc EDI DIALING AS THE NUMBER DIALING HAS BEEN COMPLETED.AFTER THE DIALING 15 L RT TEST REMOTE TEST STATION TEST 4-1118AW1 (BY OTHERS) SS000672 COMPLETED,THE DIALER CAPTURE MODULE RETURNS A HANDSHAKE TO THE ; FIRE PANEL.THE FIRE PANEL THEN SENDS THE CONTACT ID REPORTS TO THE 20 AMP CI CUIT(LOCED) DIALER CAPTURE MODULE,WHICH IN TURN SENDS A KISS-OFF AFTER THE $H=SHIELDED g (BY OTHERS) REPORT IS SUCCESSFULLY RECEIVED FROM THE FIRE PANEL. THE DIALER 'WIRE MUST BE SHIELDED AS INDICATED TW=TWISTED B- CAPTURE MODULE SENDS THE CONTACT ID REPORTS TO THE COMMUNICATIONS SYSTEM MODULE.WHEN ALL THE REPORTS ARE SENT,THE FIRE PANEL GOES ON-HOOK. DOCUMENTATION THE COMMUNICATIONS MODULE THEN TRANSMITS THE MESSAGES TO THE LES SCHWAB TIRE CENTER ysR AS-BUILT DRAWINGS CENTRAL STATION. �2 E5 . 166D7 SMOKEY POINT BLVD I 8 ARLINGTON,WA 98223. �e DESIGNED BY: P.ROJAS BY: P.ROJAS €� CHECKED BY: 04/25/2025 6 JOB/CASE#: 1-917JWV1 F5 SHOP DRAWINGS fig^ RISER DIAGRAM NOTE o a DEVICE WIRING SHOWN IS CONCEPTUAL.POINT TO POINT CONNECTIONS MAY VARY.REFER TO FLOOR PLANS FOR REQUIRED EQUIPMENT LOCATIONS.THE ELECTRICAL CONTRACTOR SHALL REFERENCE EQUIPMENT s= INSTALLATION DOCUMENTS,DRAWING TERMINATION DETAILS,AND RISER DIAGRAM FOR COMPLETE EQUIPMENT INSTALLATION. SHEET, i SHOULD ANY CONFLICT ARISE BETWEEN DESIGNED PLANS,BATTERY CALCULATIONS,VOLTAGE DROPS,AND ACTUAL INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF JCI IN WRITING UPON DISCOVERY AND PRIOR To ELECTRICAL ROUGH. RISER DIAGRAM rt CALCULATIONS RISER DIAGRAM x2 B ¢s GG FA201 3b ppG� Ie 1­I...I...I.r.1 30"X42"-ARCH E1 SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/202512:11:12 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTCfdOngton_WA_FA_DD01_i-91 ZJWVI.dwg FIRE RATED CONCRETE BLOCKWALL FIRE RATED GPY. WALLBOARD FIRE RATED GPY. WALLBOARD CEILING TO WALL TRANSITION AND OPEN WIRING A C-AJ-1045 W-L-1001 W-L-3149 Johnson CONDUIT PENETRATION U.L.C-AJ-1045 Controls CONDUIT PENETRATION U.L.W-L-1001 JOIN SON CONTROLS i OR 2 HOUR RATED CONCRETE GLOBAL CENTER OF BLOCK WALL ASSEMBLY 3M FIRE BARRIER CP 25W6+CAULK OR EQUAL 1 OR 2 HOUR RATED GYP. Aj 3M FIRE BARRIER a2OD E,CO 80012 AVE n1aNCE WALLBOARD ASSEMBLY CP FIRE25W B CAULK OR EQUAL CABLE PENETRATION U.L.W L-3149 AURORA,co Boo12 1-8F/-330-7404 1 OR 2 HOUR RATED GYP. WALLBOARDASSEMBLY 3M FIRE BARRIER CP 25W1+CAULK OR EQUAL PACKING MATERIAL CABLE OR CONDUIT CABLE BUNDLE CENTER OF EXCELLENCE NETWORK FIRE ALARM WIRE NOTES: NOTES: NOTES: 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 1 CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALLASSEMBLY. CONDUIT CONDUIT SHALL BE INSTALLED AT CENTER OF STUD CAVITY WIDTH AND KEYPLAN: 1 SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2 THE ANNULAR SPACE BETWEEN CABLEICABLE BUNDLE AND PERIPHERY OF OPENING SHALL BE 2 THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE 0 TO 1-3/8" CAULK FILL MATERIAL SHALL COMPLETELY FILL ANNULAR SPACE D TO ill. 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. BETWEEN CONDUIT AND WALL;AND WITH A WIDTH OF 1/4"DIAMETER 3 MAXIMUM OF A 1"DIAMETER CABLE BUNDLE PER FIRESTOP SYSTEM. PACKING MATERIAL-MINIMUM 4"THICKNESS OF MINIMUM 8 PCF MINERAL 2 BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS OF CAULK MATERIAL-MINIMUM 5/8"THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, WOOL BATT INSULATION SHALL BE FIRMLY PACKED INTO OPENING AS A THE WALL. FOR CONDUIT 1"DIAMETER AND SMALLER,ANNULAR SPACE 4 AT THE CI AB BOTH SURFACES LBOARD INTERFACE AT POINT CUM 112"DIAMETER LOCATION BOTH SIDES O LIE FLUSH BEAD OF CAULK APPLIED D L. 4 PERMANENT FORM. PACKING MATERIAL SHALL BE RECESSED FROM BOTH SHALL BE 0 TO 3/16". FOR CONDUIT 4"DIAMETER AND SMALLER, NOTES: SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED ANNULAR SPACE SHALL BE 0 TO 1-1/2". 5 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. THICKNESS OF CAULK MATERIAL, 3 MAXIMUM OF(1)CONDUIT PER FIRE TOP SYSTEM. 1 CONDUIT SHALL BE USED FOR ALL EXPOSED FIRE ALARM CABLING INSTALLED BELOW JOISTS AND BEAMS. 5 CAULK MATERIAL-MINIMUM 1/2"THICKNESS OF FILL MATERIAL SHALL BE 4 CONSULT CURRENT U.L.FIRE RESISTANCE DIRECTORY FOR DETAILS. 2 CONDUIT SHALL BE A MINIMUM OF 3/4". APPLIED WITHIN THE ANNULUS,FLUSH WITH BOTH SURFACES OF THE WALL. CONTACT INFORMATION: DEVICE MOUNTING HEIGHTS POWER DISCONNECT DROP CEILING Et J BOX PHONE CONNECTION DEVICE MOUNTING HEIGHT REFERENCE(PER NFPA 72) I monwn°exz� nawrx DMARC } 1-0115—DEVICE LINE i+T+I ux.+surFMExn RJ 31X BLOCK RED GREEN FIRE AWUI PANEL FIRE 4LAflu,PANEL BLACK s m,ry aer°m"xrs x YELLOW RJ CORD RJ 31X BLOCK }s my.uus uxeu,z — sxnu eervmu�rlireceuxe roexx 000R e°nw, =o�� ± �!oD musaumsunsxoxm � � LINE TO PHONES �ANPP 1 yII 1 �Quo El 1—Er rxe RED F BwxTM w xrin To enovr rixls an anon nr,cnrcr MTAGON JUN TION E. GREEN I I TELCO LINE GIBBENS DRAKE:SCOTT,LNC BLACK sv esiREe B1 Txan iu exrae=°orview BDsalPrlou 90� CONDUIT RJ CORD xAreOwN,narssotin:Hl±±xx _ �Auun ruusrnn oN DISTRIBUTION PANEL YELLOW Asr Nwu l+°e a na•a;"MF..NnLN,Em IIIIII IIIIII OR RJ CORD — 0 o N .PFA—TRO=°. pro IIIIIIIII O IIIIIIII( .x M.x ern=.,ax��con.o=r.,xc ,wx w,", IrL�IIL7 col+DNrt 4 z 2 z Cr=• TA4 cRwnaN +' PRIMARY PORT CEPIICIRCUTATREALOCKED b —11—Ell 11T11 Ill— go weu KER FIRE ALARM DISCONNECT TO DEDICATED LOCKED BRANCH E ToaRculr lzB vpuzOAMP souacE O 4G15'iti'N '' E mrnnusr rnrr o-r,F sworcr mrcron..c PRIMARY PORT SECONDARY PORT NMI BURGLAR PANELHEAT C11CFOR '-Sy Tx—T s°ceor ne s"Des macron ac OOO FIRE ALARM PANEL SQUARE _ orncauuc ITI.}x, LUNCTIC,ox .",�io - - a•F- •� 7 fe- - I• -} - rill joixwxpoe a.�cPP° 'crow iie?�i ouiiocu�ixm�oW ciiuNe €62 DEVICE WIRING STROBE - HORN/STROBE DEVICE WIRING AUDIBLE DEVICE WIRING OS&Y TAMPER SWITCH GATE VALVE WATERFLOW Et BUTTERFLY TAMPER SWITCHES `BF �a1a°coNDmr R€ g€ i nr..aR : Rw:Po FLOW S}yITCH S a£ ,zs°,C Anu,arax[aeWrvueNrl �t BREAK WIRE s" BREAK WIRE DO NOT LOOP 1 rz•wP FIEx coNDurt a€ ( r FIRE RATED DO NOT LOOP / sPaINKLta wsEx CABLE STROBE STROBE/HORN + .n O O �= PRECEDING HORN _ \ OR EDE CONDUIT ,2 1-N 0 RESISTOR + + OR POWER SUPPLY 4Raaxw�EGyER NEXT HORN OR EOL a AT LAST FIRE RATED CABLE Q' 0' DEVICE PRECEDING OR CONDUIT EOL BREAK WIRE o FROM STROBEST DO NOT LOOP p swcn,�,m BurrERav TawER SWITCH RESISTOR . � gDEVICE ORSU PLY AT LAST + rz•wP xcoNDUIT $ DEVICE g s � ISSUE LOG: & PRECEDING STROBE xx,N,r Nnxur ate" —N —1 INT DESCRIPTION _ Pow OR POWER SUPPLY NEXT STROBE OR EOLPRO —11 WAUL _s NOTES: v$ 3X o� €^c $q FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION FIRE ALARM COMMUNICATOR CONNECTION HEAT DETECTOR Ev CELL-CAB-FL HONEYWELL HWF2-COM TELGUARD TG-7FS 5601P €_ A=3 1l2"Octagonal box B=4"Octagonal box 5 C G=Single 0: 4"square With gangD.Z boz antl flu-EUlla .r ring °g ANTENNA 1MI�Ipl1�1 Y D=Directly to WaILICeiling o w�MP->t REMOTE SURFAC&fAOUNT p d e ANTENNA INCOMING 0 e o P R TELco A D y 5 N U TE PHONE E BATTERY WIRING i p F, SHOULD BE AT LEAST ©� © B E� °0 1/4"APART FROM AC 0 © 8= WIRES O B V � A ,�! LES SCHWAB TIRE CENTER ms O ® ! �•� BATTERY DIGITAL TG-7F5 e A FLUSH-MOUNT goaeTo O + � ❑ D t O tocrcwaSHEan NT n,11I r D 00 rxcr°,�°,`,°� ALARM PANEL IM WIHDa Diagram-Siaala OlrauKM h,: 16607 SMOKEY POINT BLVD. xe O ARLINGTON,WA 98223. 5 p •Off, 0 (N.C.) O ® $ STC1 TAMPER ,J 4 E C�niro Auxiliary DESIGNED BY: P.ROJAS o U aTBtOM e�nx U 3 2_ Panal OR (N.O.) SWITCH R S IE-„a- D a� CONNECTOR _ DRAWN BY: P.ROJAS ssIf - CHECKED BY: 04/26/2026 I,ISE O O O EARTH GROUND JOB/CASE k: 1-912JWV1 AMP 0 IM L AC(12V BOOMA) wiHaa Diaaeam-Bum ciRmt Mogul.: = _ 7ANBATTERY CONNECTOR p TRIP INPUT reinstall tloor O O + H P DRAWINGS Co.. EOL OR Auxiliary Auxiliary g NOTE:WHEN USING THIS SCHEME,THE USE OF THE PRIMARY OR SECONDARY DIALER TO Panel Auxiliary Auxiliary Device Device a e NOTE:THE CELL-MOD(C)/CELL-CAB-FL OFFERS AN OPTIONAL GSM COMMUNICATOR CARD FOR CENTRAL STATION REPORTING.IT MOUNTS CONNECT TO TELCO IS WHAT DETERMINES WHETHER THE TG-7 IS MEANT TO WORK AS A Device Device SHEET: IN ITS OWN PLASTIC ORMETAL ENCLOSURE.USE OF THE CELL-MOD(C):CELL CAB FL REQUIRES THE IPOTS-COM COMMUNICATOR. BACK-UP OR PRIMARY COMMUNICATOR. USE EITHER AC POWER(FROM ADAPTER)WITH BATTERY OR USE DC POWER(FROM PANEL). 0 PRODUCT TYPICALS PRODUCT TYPICALS o FA301 o �a I I•r•I• I I 30"X 42'-ARCH El SIZE GCOE TEMPLATE:3.2 LAST PRINTED:8/19/2025 12:11:14 PM LAST SAVED BY:LUCAS.FOSTER FILE PATH:K:\20256343\20256343.DWG\LSTC_ArttngtoD_WA_FA_DD01_1-91ZJWV1.Owg