Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16512 51ST AVE NE_BLD6473_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16512 51ST AVE NE Permit#:6473 Parcel#:31052800101000 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Mechanical systems for new warehouse building w/office. Valuation:138429.00 APPLICANT CONTRACTOR SINGH H/LALLI I/DHILLON D/S/R K Evergreen Refrigeration EVERGREEN REFRIGERATION 8520 79TH AVE NE 727 S Kenyon St 727 S KENYON ST MARYSVILLE,WA 98270 Seattle,WA 98108 SEATTLE,WA 98108 206-763-1744 206-763-1744 UC:602512953 EXP:05/31/2026 LIC:EVERGRL954R2 EXP:01/06/2026 MECHANICAL CONTRACTOR , PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2021 STORIES: 1 CONST.TYPE: ll1B DWELLING UNITS: OCC GROUP: S-2;Storage Low Hazard BUILDINGS: OCC LOAD: PERMIT APPROVAL . The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. j" 09/30/2025 � r 09/30/2025 Applicant Signature Date Building Official Date _ CONDITIONS Adhere to approved plans.Permit shall be onsite for inspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/30/2025 Web Only-Mechanical Commercial Plan Review $1,183.60 09/30/2025 Processing/Technology $25.00 09/30/2025 Air Handling Unit $15.00 09/30/2025 Diffusers $15.00 09/30/2025 Ductwork/Dryer Duct $25.00 09/30/2025 E)(haust/VentsNent Fans $105.00 09/30/2025 Mechanical Msc. $45.00 09/30/2025 Unit Heaters $75.00 09/30/2025 Unit Heaters>100 BTU/h $150.00 09/30/2025 Mechanical Msc. $25.00 09/30/2025 Credit Card Service $14.40 Total Due: $1,678.00 Total Payment: $1,678.00 Balance Due: $0.00 ' CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: 0 New Installation ❑ Addition ❑ Alteration ❑ Replaced ❑ Gas Piping Type I and Type II Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 16512 51 st Ave N E Project Valuation: $138,429.00 Lot#: Parcel ID No.: 31052800101000 Preferred Contact: O Owner 0 Contractor Installation of one(1)rooftop unit,one(1)energy recovery ventilator,five(5)electric wall heaters,six(6)electric unit heaters,seven(7) Project Description: exhaustfans,two(2)roof hoods,one(1)louver,ductwork,and grilles/diffusers. Owner Name: DHILLON DALJIT S&RAJINDER K&SINGH HARINDER&LALLI IQBAL Office No.: Email Address: Cell No.: Mailing Address: 8520 79th Ave NE City: Marysville State: WA Zip: 98270 Contractor Name: Evergreen Refrigeration Office No.: 206-763-1744 Email Address: alexb@evergreenhvac.com Cell No.: N/A Mailing Address: 727 S Kenyon St City: Seattle State: WA Zip: 98108 L&I Contractor License Number: EVE RGRL954R2 Expiration Date: 1/6/26 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable O CSST 71 Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8 O 3/4" O 1" 71 11/2" O 2" Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Alex Burkhart Alex Burkhart 4/30/25 Signature Print Name Date REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Air Handling Units 1 x $ 15.00 = $15.00 Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $15.00 Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) 1 x $ 25.00 = $25.00 Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans 7 x $ 15.00 = $105.00 Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired Air Conditioning Unit 15 100 Btu h x $ 15.00 = $ Gas Fired Air Conditioning Unit> 100 Btu h x $ 25.00 = $ Gas Fired Air Conditioning Unit> 500 Btu/hp x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping for each additional unit > 5 x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by 3 x $ 15.00 = $45.00 mechanical code,not otherwise specified Package Units:5 100 Btu > 100 Btu 1 x $ 25.00 $50.00 = $25.00 Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee all x $ 75.00 = $ Unit Heaters <_ 100 Btu h 5 x $ 15.00 = $75.00 Unit Heaters>100 Btu h 6 x $ 25.00 = $150.00 Variable Air Volume Boxes (part of Air x $ 10.00 = $ Conditioning System) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $480.00 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2024 Page 2 of 3 172NDSTME DUCT INSULATION TABLE PER TABLEC403.10.1.2 GOVERNING CODE INFORMATION GENERAL NOTES w wmmtEw� x DUCT SYSTEM DUCT LOCATION AND USE 2021 WSEC REQUIRED TYPICAL EXAMPLE 202I INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS INSULATION R-VALUES 2021 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS DUCTWORK 2021 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 2021 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS,ADD 2"TO EACH 2021 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC DIMENSION TO OBTAIN OUTSIDE DIMENSION.ADD 4'TO EACH DIMENSION IF THE DUCTWORK IS ON THE EXTERIOR OF THE BUILDING. OUTSIDE BUILDING ATTIC VENTED TO AMBIENT/ROOFTOP 1-5 SUPPLY/RETURN EXPOSED TO WEATHER/AMBIENT CONDITIONS R-8 DUCT 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND IS THE HEIGHT. SUPPLY/RETURN UNCONDITIONED SPACE R-6 ENCLOSED ATTIC W/0 VENT COMMISSIONING PLAN 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS W� UNCONDITIONED SPACE W/AMBIENT CONDITIONS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THEN 50,PER IMC 602.2.1. _ z SUPPLY/RETURN WITHIN IT50FIO OF DESIGN AIRFLOW TEMPERATURE R-3.3 DUCT WITHIN CEILING PLENUM 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN as ALL COMMISSIONING OF HEATING,VENTILATION AND AIR CONDITIONING SYSTEMS AS 0 112 INCHES AND 2 INCHES.DUCTWORK WHICH IS DESIGNED TO OPERATE AT SPIRAL DUCT IN OPEN CEILING REQUIRED BY SECTION C408"SYSTEM COMMISSIONING"OF THE 2021 WASHINGTON STATE PRESSURES ABOVE 112 WATER COLUMN SHALL BE SEALED IN ACCORDANCE WITH SUPPLY/RETURN EXPOSED DUCT WITHIN THE ZONE IT'S SERVING NONE TERMINATING IN SAME SPACE ENERGY CODE(WSEC)SHALL BE PERFORMED BY EVERGREEN REFRIGERATION,LLC.THE STANDARD RS-7. ' ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE SCOPE OF WORK DUCT THROUGH CEILING RETURN PLENUM COMMISSIONING COMPLIANCE CHECKLIST"SHOWN BELOW.AT THE COMPLETION OF THE 1.5 ALL DUCT GAUGES PER SMACNA,IMC 603-4. C DUCT WITHIN CONDITIONED SPACE,DOWNSTREAM OF ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC THE RETURN/EXHAUST R-8 BETWEEN ERV AND MOTORIZED DAMPER AT COMMISSIONING COMPLIANCE CHECKLIST" WILL BE REVIEWED WITH THE BUILDING 1.6 ALL DUCT SUPPORTS PER SMACNA,IMC 603-10. / ERV,UPSTREAM OF ISOLATION DAMPER ENVELOPE PENETRATION OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED.THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR PER WA STATE 8 LOCAL CODES. A DUCT THROUGH CEILING RETURN PLENUM ACCEPTED AS REQUIRED BY SECTION C408.1.3 OF WSEC. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. V RELIEF/EXHAUST DUCT WITHIN CONDITIONED SPACE, R-16 BETWEEN MOTORIZED DAMPER AND UPSTREAM OF ISOLATION DAMPER ENVELOPE PENETRATION INSULATION m N ru m OUTDOOR AIR LESS THAN 2.1 WHEN PRESENT,INSULATE OR LINE DUCTWORK PER WA.STATE ENERGY AND MECHANICAL sy1. 2800 CFM v rolect DUCT WITHIN CONDITIONED SPACE R-7 DUCT THROUGH CEILING RETURN PLENUM M-xnme: CODES. 0 ENERGY CODES. o 2.2 WHEN PRESENT,INSULATE REFRIGERANT&CONDENSATE PIPING PER STATE&LOCAL neerecs: 0 OUTDOOR AIR GREATER INSIDE CONDITIONED SPACE, DUCT FROM MOTORIZED DAMPER AT THAN 2800 CFM DOWNSTREAM OF MOTORIZED DAMPER R 8 ENVELOPE PENETRATION TO HVAC UNIT eNaoamnnoN u„a�,�,mmi==inning,mre:.innei: GENERAL CONTRACTOR DUCT FROM MOTORIZED DAMPER AT HVAC Tyvo orzw umwc....onexummr: 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP,CEILING, Y 3 N OUTDOOR AIR GREATER INSIDE CONDITIONED SPACE, THAN 2800 CFM DOWNSTREAM OF MOTORIZED DAMPER R-16 UNIT(LOCATED INSIDE BUILDING)TO FLOOR,AND WALL PENETRATIONS,INCLUDING WEATHERPROOF SEALING AND FIRE PROOF , ., 'w ENVELOPE PENETRATION POINT LININGS PER IMC&IBC. ❑ x ininy no mneo com xe(SECTION a03.6) 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL n¢0 3 suvvoanxc on+„wnense mo«er„1a0 6n Jewess„wsnrno 1O T.s owxsv BEFORE FRAMING OPENINGS. n v)a 3 AIR TERMINAL UNIT SCHEDULE SUPPLY OQamsNTs uu(a036zn�vss ex smnirxo ro me n 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION,PATCHING,AND PAINTING AS r�ox mio3.6s xes xEm,wo.Om REQUIRED FOR MECHANICAL WORK. xma¢io3.au xu sssx mwms° 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR ITEM MARK MANF. MODEL MATERIAL FINISH SIZE NOTES DIFFUSER SIZE mme owxex wunsou:so onr MECHANICAL WORK. �,TAIl. comm)ss(oNnrG c mmi 3.5 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL T' ❑ ° oxomrcvn.aw.o:xoeeaxavteiwemcewalsonioxc40e.t.z) EQUIPMENT. O WAS 7 J' SIZE RANGE vwu 3.6 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL 4 HNc t(' i VICINITY MAP omm)ssiOrv)Nc nmm, CANT STRIPS AND CURB INSULATION,AND SEAL AGAINST LEAKS T BORDER TYPE 36=T-BAR ❑ n-iuea(secmn ca08.r.3) �Q tj) CEILING DIFFUSER CD-I PRICE SMCD STEEL WHITE SEE SCHEDULE ocnorci.iswzom wmoiaa°aoa mocommi.oioaiaov 3.7 GENERAL CONTRACTOR T PROVIDE ALL CUTTING AND PATCHING OR T-BAR CEILING AS 5 BORDER TYPE 6=HARD LID REQUIRED FOR HVAC INSTALLATION. r 6"X 6" 0-100 CFM ❑ reasscsocrron c40s.z) 3.8 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR NOT TO SCALE CEILING GRILLE CG-I PRICE 80 ALUMINUM WHITE NECK SIZE SQ. BORDER TYPE 3=T-BAR x DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING 8"X 8" 101-250 CFM ❑ Toninv,oa)uzrmvona 6ounona is mmviete lsecnvn c40e.z.z) CODE,WHERE REQUIRED BY SECTION 707 OF IBC. NOTES: w nnrssoiwa aebn;enaes wim me mecnnmmiwmm. I.ADD MANUAL VOLUME DAMPER TO EACH SUPPLY DIFFUSER BRANCH. 10'X 10" 251-425 CFM mereereae:<,iceamme 0�2287❑ ,Tha`nmmeco,,,mi�ion;nyaevorcaem;ueammnOwrer ELECTRICAL O '�Cj ��4 z 2.ADD MANUAL VOLUME DAMPER TO EACH EXHAUST RETURN GRILLE BRANCH. G� 12'X 12" 426-650 CFM x.,unssynm:werei,Kivammmecommis:ioninyvrocoss(semonwaea) 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING,CONDUIT WILL BE PROVIDED `rSIONAL ❑ m eawa aebmenaes wmn me serriewmer ring.wsrem.anew nre aes<anm;n me BY ELECTRICAL CONTRACTOR. mm, m-d 1n1he ow,w.nm 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL DISCONNECTS,AND STARTERS FOR ELECTRICAL CONNECTIONS, MECHANICALEQUIPMEN HEAT PUMP PACKAGE EQUIPMENT SCHEDULE ❑ weave w,auvn my um ni r wom maaamm no cemmissie°i v 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES,LOADS AND LOCATIONS, m�(sernnn c4o6.4) WITH ERL MECHANICAL PLAN AND WITH FIELD LOCATIONS. FAN COOLING HEATING ELECTRICAHMCI ❑ m oxa/or ovmx,onc nynnvy roxeiu:.T- 4.4 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER.IF APPLICABLE. CURB xe a�r.mmr�nxmoonomcm cm��ss�ommny acr�rzmr'arearome C. 4.5 ELECTRICIAN TO PROVIDE APPURTENANCES IN ACCORDANCE WITH NEC 210.63,AND FILTER SIZES FILTER WEIGHT ALL OTHER APPLICABLE SECTIONS. MARK MANF. MODEL TONS AIRFLOW MIN.OSA ESP MOTOR TOTAL TOTAL COP COP STRIP M.C.A. WEIGHT NOTES sysrems naaroova sr...worei.-1.mo amm-.1.vvroa.o(somm c40ssl DRIVE TYPE SEER2 HSPF2 HEATER V 0 No.(LxWxD) TYPE (Ib) (Ib) ❑ PLUMBING (CFM) (CFM) (IN-WC) BHP (BTU/h) (BTU/h) (@47°) (@l7°) (kW) (A) ❑ mere nre nnrssoiaa aebmenaos wmn,ysm:mre mreaMe4o6wwoz ms,e nre aescanoa;n sne onocnoa wmmis:ionise aoaort manimammo ownor. 5.1 PLUMBING CONTRACTOR OFFSETS VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR ❑ mmi:q Systems were incluaee in qe cmnmus:o inS Fasess 0-.U08.6) INTAKES OR 3'ABOVE HIGHEST POINT OF INTAKE,IMC 401.4 5.2 CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. RTU-I CARRIER 50GCQJ06B2A6-8UOA0 1 5 1 2000 1 290 1 1 1.19 1 VANE AXIAL 1 61,930 1 16 1 57,040 1 3.8 2.7 1 T5 1 5.5 1 460 3 1 22 1 25 1 L.06'xl6-x2') MERV 13 1 115 1 648 1 1,2,3,4,5 ❑ m ,omne ae�vwc wemiemmmeowneorm.niq sysxm.mae are aescanea in me ammea ENERGY CODE COMPLIANCE NOTES: ❑ xomemozioo sy.tome were ineiueee in me eanmmioniny pN-0-.e40s.37 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY 2 CONDENSATE EC DRAIN TO APPROVED LOCATION BY PLUMBING CONTRACTOR. INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN 2.WIRING BY ELECTRICAL CONTRACTOR. ❑ m reore nnromiwaaora�ao:msnm Nmth q0 rea Wsecaon wz0.Tnore Oro e�oieoammo THE ZONE.AT MINIMUM ,EACH FLOOR SHALL BE CONSIDERED A ZONE. 3.UNIT COMES COMPLETE WITH AN ECONOMIZER AND NIGHT SETBACK THERMOSTAT. onamoa comm¢aon;ry aovorc m,6minoammo owiw. 6.2 OUTDOOR AIR SUPPLY,EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE PROVIDED WITH 4.INSTALL WITH FACTORY CURB.FIELD VERIFY LOCATION. CLASS IA MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF 5.PROVIDE WITH SINGLE POINT POWER CONNECTION. ❑ wN n xoxasreo�„ PER WSEC SECTION C403.7.8. .rromexwm rxEwe:«w�'oxs.nEEEco`.aro�LLrffE �E°" MECHANICAL CODE COMPLIANCE u rmwo cawnsmrvs rosmme: mre 71 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN. N ENERGY RECOVERY VENTILATOR SCHEDULE EXHAUST FAN SCHEDULE EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM.DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. V ELECTRICAL eeannunoN ❑ �.<mmnxu mm r.wnsn ox�im s.nre Exs�,coin�.noo,w eic r.,rens esow. x��,„ H M COOLING HEATING TEMP ELECTRICAL AIRFLOW ESP WEIGHT WA2021 N AIRFLOW ESP MOTOR WEIGHT MARK MANF. MODEL NOTES MARK MANF. MODEL (CFM) (IN-WC) (W) TOTAL TOTAL EFF. V 0 MCA MOCP Qb) NOTES (CFM) (IN-WC) V 0 MCA(A) (16) 0wmme owxm ox owms asw�mrerws 0ers 00 EFF.(%) EFF.(% M (A) (A) SYMBOL LEGEND w o z LU Q EF-I BROAN LIOOE 100 .25 120 .3 18.9 NOTE:NOT ALL SYMBOLS SHOWN ON THIS LEGEND MAY w Q ERV-1 LOSSNAY LGH-F300RVX2 300 235 50 63 65.5 208 4.3 15 75 EF-2 BROAN LIOOE 1 100 .25 120 1 .3 18.9 PERTAIN TO THIS PROJECT. = Q NOTES: NOTES: VENTILATION TABLE V) M 2!I.INCLUDES STANDALONE CONTROLLER AND BACKDRAFT DAMPERS. O I.SWITCHED TO OPERATE WITH ROOM LIGHTS BY ELECTRICAL CONTRACTOR. ROOM OSA OSA TOTAL O"X2On RECTANGULAR DUCT � O r-I ROOM OCCUPANT OCCUPANCY DESIGN AREA CFM/PERSON CFM/SF REO LU = Ln I'D (SF) [I] [I] OSA CFM N NAME DENSITY[I] (#PEOPLE) OSA CFM 10"0 ROUND DUCT Z ROOFTOP EXHAUST FAN SCHEDULE LOUVER SCHEDULE MOTORIZED DAMPER oe ROUND SPIRAL DUCT O O � iY AIRFLOW ESP MOTOR WEIGHT SCHEDULE MARK MANF. MODEL V 0 NOTES MARK MANF. MODEL SIZE FREE AREA LOCATION �TT] U Z '� Q (CFM) (IN-WC) HP (Ib) FT EQUIPMENT VOLTAGE LOBBY AND OPEN OFFICE 838 5 4 5 0.06 71 71 �-�-w-y-�"_'"-' FLEXIBLE DUCT CONFERENCE OFFICE 105 215 50 II 5 0.06 67 67 ® ® SUPPLY DUCT SECTION REF-I GREENHECK GB-I60-7 2,850 .125 460 3 .75 97 1 L-I I GREENHECK ESD-435 70"X70" 19.67 FIRE SPRINKLER ROOM REF-1 120 OFFICE 102 159 5 1 5 0.06 14 14 RETURN DUCT SECTION REF-2 GREENHECK GB-I60-7 2,850 .125 460 3 .75 97 REF-3 GREENHECK GB-160-7 2,850 .125 460 3 .75 97 I OFFICE 103 194 5 1 5 0.06 16 16 ® ® EXHAUST DUCT SECTION ZO REF-4 GREENHECK GB-160-7 2,850 .125 460 3 .75 97 OFFICE 104 213 5 1 5 0.06 18 18 F ROOF HOOD SCHEDULE ® SUPPLY DIFFUSER REF-5 GREENHECK GB-330-15 10,000 .125 460 3 1.5 252 2 BREAK Room 106 511 25 13 5 0.06 95 95 0! MARK MANF. MODEL CFM SIZE ® V) U RETURN/EXHAUST GRILLE NOTES: CORRIDOR 96 0 0 0 0.06 6 6 W 1.SWITCHED TO RUN CONTINUOUSLY BY ELECTRICAL CONTRACTOR. 2.SWITCHED TO RUN BY FIRE PUMP CONTRACTOR. IH-I GREENHECK FGI-4OX40 5,J00 40"x40' RESTROOM 107 64 0 0 0 0 0 0 0 $IDEWALL DIFFUSER PER IMC TABLE 403.3 WAREHOUSE FANS TO EXHAUST MINIMUM OF 0.06 CFM/FT' IH-2 GREENHECK FGI-4OX40 5,700 40"X40- RESTROOM 108 64 0 0 0 0 0 0 CEILING MOUNTED WAREHOUSE AREA=159,200 FT EXHAUST FAN MINIMUM EXHAUST ALLOWED=159,200 FT2 a 0.06 CFM=9,552 CFM/FTz<11,400 CFM=(4 FANS e 2,850 CFM) RESTROOM 109 64 0 0 0 0 0 0 INLINE FAN W ELECTRIC WALL HEATER SCHEDULE ELECTRIC UNIT HEATER SCHEDULE RESTROOM 0 64 0 0 0 0 0 0 MANUAL VOLUME DAMPER Q NOTES: ZONE DAMPER AIRFLOW HEATING ELECTRICAL WEIGHT FAN HEATING ELECTRICAL I.PER IMC 403.3 a TABLE 403.3.1.1. MARK MANF. MODEL INPUT NOTES MARK MANF. MODEL WEIGHT NOTES M MOTORIZED DAMPER (Y (CFM) V 0 (Ib) AIRFLOW MOTOR INPUT OUTPUT M.C.A. (lb)(kW) (CFM) HP (kW) (BTU/h) V 0 (A) 1--I PERMIT SET Iq BACKDRAFT DAMPER ■ LJ DATE: 4.30.25 EWH-I KING PAW1215 75 1.5 120 1 9.5 1,2,3 FIRE SMOKE DAMPER ISSUED FOR EH-I KING KFUH4860-3-2S3-ECM 4,284 (2).75 60 204,800 480 3 72.2 170 1,2 020V POWER REQ.) EWH-2 KING PAW1215 75 1.5 120 1 9.5 1,2,3 CONSTRUCTION ❑ EH-2 KING KB4840-3-PLTMX-FB 3,500 (2).25 40 136,500 480 3 48.1 100 1,2 � FIRE DAMPER EWH-3 KING PAW1215 75 1.5 120 1 9.5 1,2,3 City of Arlington DATE: ---- EH-3 KING KFUH4860-3-2S3-ECM 4,284 (2).75 60 204,800 480 3 72.2 170 1,2 T EWH-4 KING PAW1215 75 1.5 120 1 9.5 1,2,3 Building Department O THERMOSTAT AS BUILT EH-4 KING KFUH4860-3-2S3-ECM 4,284 (2).75 60 204,800 480 3 72.2 170 1,2 g p ❑ EWH-5 KING PAW1215 75 1.5 120 1 9.5 1,2,3 APPROVED ®D SMOKE DETECTOR DATE: ---- NOTES EH-5 KING KB4840-3-PLTMX-FB 3,500 (2).25 40 136,500 480 3 48.1 100 1,2 NORTHSOUND LOGISTICS : 1.WIRING BY ELECTRICAL CONTRACTOR. EH-6 KING KFUH4860-3-2S3-ECM 4,284 (2).75 60 204,800 480 3 72.2 170 1,2 Kevin Olander- 05/09/2025 O SENSOR COVER SHEET 2.WITH INTEGRAL THERMOSTAT. 3.PROVIDE WALL BOX. NOTES: NO changes authorized unless approved b LINE VOLTAGE DWG BY: JC .WIRING BY ELECTRICAL CONTRACTOR. g pp Y THERMOSTAT CKD BY: KT/AF 2.WITH INTEGRAL THERMOSTAT. the Building Official TC TIME CLOCK JOB NO.: 524380 ERV ERV CONTROLLER SHEET::M`/w, e EQUIPMENT TAG 00 1 250 FM C CD-I DIFFUSER/GRILLE TAG W SW> \ o r F O� W Z _ OSE ► � Y3V� aw O 3 UP TO UP TO TA xI REF-1� REF-2� Jv WAS w a O �0052287� z ,A, CISIE¢ SfONAL� EH EH EH (tx\ 2 3 U z M Q N JJ Ur W � UP TO � OO W Q IH-I � ¢ Q Q 2 O OO � H r4 Z -- --- -- -- -- - W O kD iY - --_ i------� r-------: r-------� r-------i r---- r r r � � r------� r----: r— � r-------i r---- r r----� r---� r-----� r-----i r-------i Z ,� Q z o e o e O a LA 0 0 0 o w LU Q PERMIT SET DATE: 4.30.26 ISSUED FOR CONSTRUCTION DATE: ---- AS BUILT City of Arlington DATE: --- Building Department NORTHSOUND LOGISTICS WEST HVAC PLAN APPROVED WEST HVAC PLAN 1 SCALE: 1/16°=1' Kevin Olander-05/09/2025 DWG BY: JC CKD BY: KT/AF 0 4' 8' 16 32' No changes authorized unless approved by JOB NO.: 524380 the Building Official SHEET: M201 W �\> SW> \ o r F OI W Z y (Y pW o aw 1 I W 3 z UP TO UP TO 1 REF-3 REF-4 _ ��,TAj� I � O WAS 1' NCT�� x I 03 5P x O �0052287� z ,A, CISIE¢ SfONAL� I I I EH EH 4 EH 6 5 I U z M � N W I UP TO d 0 Z IH-2 0 > I U Z Q z 2 � OF-- I Y- ----------,,I ---------,,I ---------,, - -- - --i - - -- Q 0 IW Z ,--i Q i I i i i I i i i i I I i i I I i i i 1 I I a I Z I I I a I I Ln I I 1 I I 1 I ~Q 1 I � M203 PERMIT SET DATE: 4.30.25 ISSUED FOR CONSTRUCTION ❑ DATE: ---- AS BUILT ❑ City of Arlington DATE: --- Building Department NORTHSOUND LOGISTICS 1 EAST HVAC PLAN APPROVED OVERALL FLOOR PLAN SCALE: 1/16°=1' Kevin Olander- 05/09/2025 DWG BY: JC CKD BY: KT/AF No changes authorized unless approved by JOB NO.: 524380 the Building Official SHEET: M202 W SW> \ o r F O� o S g EWH EWH 10"VENT TO ROOF 2 3 ERV B B e �v W 2"0 o a w 3 O 3 F- n�na 3 1 RESrRo DR S ix EF rog. --- — — FROM CG-I —J Y1 1 18 0 BYPASS RTU-I � .TA �P�oF WASy7NC 8 0 - CD- U 100 CFM 80 - 80 C M 5 F L 00 a 6"VENT ROOF g'0 6 0CD O PF �icy z m es cF �`rSrONAL� 100 CFM J 00 CF EF. 21 m m BREAK OOM � 10 CD- O`- 200 C M F-mRESTROOM O 8"0 m 77- F17 - 77 H E H 140 CG-I T IONFI RENCE ROOM ° U NIL d CD-I 200 C1 M ZD- Z N 6°g 8" Q U W ao CTcD-1 cD-1 J 0 Z - 00 CFM 200 CFI` Q J Q a TYP 2 D-I 5 70 FM 0 LU z 0 21fg O , 1 = In 0 0 EN 001 F CE D I o g L 75 FM OA Z 0Ln ZD-2 6„0 W Z Q LOB Y ZD-3 io EWH C 8 CD-' I80 M 200 C M Z O F „ a 4 40 6 6 0" cG 1 0" In = TYP 3 L T 80 D1 D-3 20 c M OA T z CD-I CD-I 2 CFM A 10 80 2 CFM A W Q M a"o CD-I 20 CF UP TO REF-5 OF ICE I8C CFM OFFICE 20D 1= OFFICE PERMIT SET 4 103 102 DATE: 4.30.25 SCREENED OPENING ISSUED FOR CONSTRUCTION DATE: ---- City of Arlington AS BUILT Building Department DATE: ---- APPROVED NORTHSOUND LOGISTICS FIRE SPRINKLER ROOM PLAN OFFICE FLOOR PLAN ENLARGED PLANS i 2 Kevin Olander-05/09/2025 DWG BY: JC SCALE: 1/4"=1' SCALE: 1/4"=1' CKD BY: KT/AF 2' 4 a o I z 4 e the Building Official ' ' No changes authorized unless approved by JOB -r: 524380 o SHEET: M 203 W SW> \ o r F O� a=M ► � Y3V� aw �¢O 3 n n a 3 TA J p WASy� 1 a O �0052287� z CISIE¢ rSrONAL U M U7 N 0 LU � 0 Z Z J > � g � Q z REF _ Ln C7 REF REF REF REF 5 O ,r4i _ 1 2 3 4 0 Ln / Z ,—i Q 0 E Ln IH IH 2 w RTU TYP ALL Q PERMIT SET DATE: 4.30.25 6"DOWN 16'DOWN ISSUED FOR TO EF-1,2 TO ERV-I CONSTRUCTION ❑ DATE: ---- AS BUILT ❑ DATE: -- NORTHSOUND LOGISTICS City of Arlington ROOF PLAN ROOF PLAN Burl APPROVED ent DWG BY: AF 1 CKD BY: KT/ SCALE: I/32P JOB NO.: 524380 Kevin Olander-05/09/2025 SHEET:N0 8' 16' 32' 64' No changes authorized unless approved by n� 04 the Building Official I Y' NOTE: SEE SUBMITTAL FOR nrm EXACT DIMENSIONS ucmasmurew.ausrre cvmmce«.cann«« 16 GA.GALVANIZED UNIT BASE RAIL CONSTRUCTION. NOMINAL ROOF s � OPENING J; SIZE -11" w` ATTACH TO �� 18 GA GALVANIZED UNIT 4 EACH 6„ \ STEEL OR #10 x /E H 0.064 ALUMINUM > _J� SCREW$ ATTACH 10 CURB HOLES HOLES 4 EACH#10 x I/2" I-I/4" TEK SCREWS C 2-5/8' C ROOF CURB COUNTER �'A FLASHING SEISMIC CLIP DETAIL TYP HOLD DOWN CLIP 12"-42' m ROOFING FELT MECHANICAL CURB LOCATIONS(TYP) (BY OTHERS) O E RET N �ppL� RIGID INSULATION i � i AIR yvvvv�yv (BY OTHERS) r� WOODEN NAILER w v o k Br v � 2"MOUNTING FLANGE. w O 3 vyy M xyy yy vv� y CANT STRIP CURB LEVELING MOUNT DIRECTLY (BV OTHERS) (BY OTHERS) y>R v R-13 INSULATION TO ROOF SUPPORT J�J�J�O w IN VOID SPACES STRUCTURE BY OTHERS TYP ATTACHMENT TO ��.TA7l. �py4 pF WASy�N 1� w STRUCTURE (BY OTHERS) ROOF CURB ROOF EXHAUST FAN CURB y NOT TO SCALE NOT TO SCALE 0 O �0052287� z cisr� v �`rSrONAL� UNIVERSAL CEILING City of Arlington LARGE MOUNTING MINIMUM 6" GRILLE BRACKET CLEARANCE Building Department To SIDE WALL ____ APPROVED 10�" ELECTRIC HEATER WALL CAN Kevin Olander-05/09/2025 No changes authorized unless approved by V) the Building Official —J Q U Q �- M MINIMUM 8"CLEARANCE F—I rV TO FLOOR 0 LLI BILL OF MATERIALS 0 O z z J > < TAG OTY ITEM Q z Q z A 1 HONEYWELL HZ322K TRUE ZONE D 0 B 3 HONEYWELL COMMERCIAL VISION PRO 8000 I�—I O L iim Beo C 3 BELIMO LMB-24-3—T ACTUATOR LMB2434 O Q ACTUATOR N Z D 1 LE 15550 TRANSFORMER7 a'�"`" Beiimo w J rn LMB26-3T ......��� LA ACTUATOR Q z 1�`I Q ELECTRIC HEATER MOUNTING WALL HEATER MOUNTING0 r w NOT TO SCALE 0 NOT TO SCALE a a m - V161 B L A \OEA�PNG�E B — m— HZ322K ® -- J ZO GIB45° WOOD JOIST PACKAGE L J —L a ROOFTOP UNIT m ® O' 3/8"LAG SCREW U O min] €� D � ~`" B243T SEQUENCE OF OPERATIONS ® m E.EIGE° M --� ° B ACTUATOR 3/8'STRUT NUT 2"SCREW OR 3/8"LAG BOLT u D m ® 12L— wr sysTBM 3/8"THREADED ROD -5/8"UNISTRUT R ®G. L Q ovemii sracem comroi �� m (2)3/8"FLAT WASHERS Roono a nmotle(Hearin Lz �i m �__—_ —_J_p n g,onli�g or venelarioN is tlarerminetl by Me naetls tithe —L roan me.ineiWe m�� ,t wiii instance,tlmore In a ling lineaarein need or coolingr lbanbearing, {{---mmm��- �pp jj roonop umr openae coo moee.Con versery,rc more.moss are in 1PPN0flM� nLmJ IlJ DUCTMATE VIBRATION 3/8"FENDER neee orneatmg amer man wdmq,men me rooftop Udr wiii operate " ISOLATION HANGER STEEL TENSION ins bearing made. d' BRACKET AND RUBBER PADDING inbareisnobaariegorcooungaemenabyenyoraezones,rbenroorcopannbe t PERMIT SET AIRCRAFT CABLE IF MOUNTING DISTANCE ane morns era aiaangagae,ane ma aappiy ran mngnaaamrnn Ladiiaeon moss). TO STRUCTURE IS GREATER THAN 12' ID TERM"ALSmewieaai mna coned aEVER VrRE a THa_RTHE 11RELEss ErR To TMILE`RESS TERA—TERIG—SINLY w,Ts DATE: 4.30.25 Deaths mode orppereeoa is eawbiiabm.men me znae dampers mrriwsemres ISSUED FOR ENERGY RECOVERY VENTILATOR rbera .,:re(in neee Drina as:o-ea mna cemperawre adppimmarare in neee tithe panem m �oeiingnrbaab- wiimoaaiae«parineiaiiyae,narp�irbn,in UNIT AND FILTER BOX CONSTRUCTION El Dinar ro mammm rbe eaairea:ona iamperawre aerpoima. me mna aamcers ramose moss and aranrn need Drina currem moss wiii ae�e DATE: ---- wiiydasm«wrbeirmiNmamposiripaa. AS BUILT As serpoin6 are reached and con:agpendv mna aamvera tines onrbe aymm brpaaa tla DATE:mpe matldare open in ortler w meidein eidlow Mmugb me rooftop unit and elm ro prevenn t exresaiva pressure builtlup in Ibe tludwoM. NORTHSOUND LOGISTICS DETAILS AND DIAGRAMS DWG BY: JC CKD BY: KT/AF TRUE ZONE-CONVENTIONAL JOB NO.: 524380 THREE ZONE HZ 322 SHEET: ERV SUSPENSION M 3 1 NOT TO SCALE uP0ATe0:Iziza Chvac-Full Commercial HVAC Loads Calculation Program Elite Software Development, Inc. Everqreen Refriqeration New Office Northsound Loqistics Seattle WA 98108-4327 Page 2 Building Summary Loads Building peaks in July at 1 pm. t g Load Area Sen %Tot Lat Sen Net %Net criptions Quan Loss Loss Gain Gain Gain Gain Roof 2,482 2,815 5.57 0 108 108 0.18 Wall 824 2,446 4.84 0 1,516 1,516 2.60 Glass 353 11,421 22.58 0 11,975 11,975 20.53 Floor Slab 0 0 0.00 0 0 0 0.00 Skin Loads 16,681 32.99 0 13,598 13,598 23.31 Lighting 1,590 0 0.00 0 5,430 5,430 9.31 Equipment 3,068 0 0.00 0 10,465 10,465 17.94 Pool Latent 0 0 0.00 0 0 0 0.00 People 31 0 0.00 6,109 7,636 13,745 23.57 Partition 1,200 3,300 6.53 0 1,650 1,650 2.83 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 688 0 0.00 7,630 5,271 12,901 22.12 Heat. Vent. 688 30,590 60.49 0 0 0 0.00 Cool. lnfil. 0 0 0.00 0 0 0 0.00 Heat. lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 0 0 0.00 Blow-Thru Fan 0 0 0.00 0 540 540 0.93 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 50,571 100.00 13,739 44,590 58,329 100.00 Building Sen %Tot Lat Sen Net %Net Summary Loss Loss Gain Gain Gain Gain Ventilation 30,590 60.49 7,630 5,271 12,901 22.12 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Room Loads 19,981 39.51 6,109 38,780 44,889 76.96 Plenum Loads 0 0.00 0 0 0 0.00 Fan/Duct/Misc Loads 0 0.00 0 540 540 0.93 Building Totals 50,571 100.00 13,739 44,590 58,329 100.00 Check Figures Total Building Supply Air (based on a 17' TD): 2,285 CFM Total Building Vent. Air (30.10% of Supply): 688 CFM Total Conditioned Air Space: 2,482 Sq.ft Supply Air Per Unit Area: 0.9206 CFM/Sq.ft Area Per Cooling Capacity: 510.6 Sq.ft/Ton J:\...\Elite-Northsound Revised Office-3.10.25-CE.CH8 Tuesday,April 1,2025,01:34 PM Chvac-Full Commercial HVAC Loads Calculation Program Elite Software Development,Inc. Everqreen Refriqeration New Office Northsound Loqistics Seattle WA 98108-4327 flL Pa e 3 Building Summary Loads cont'd Check Figures Cooling Capacity Per Area: 0.0020 Tons/Sq.ft Heating Capacity Per Area: 20.38 Btuh/Sq.ft Total Heating Required With Outside Air: 50,571 Btuh Total Cooling Required With Outside Air: 4.86 Tons J:\...\Elite-Northsound Revised Office-3.10.25-CE.CH8 Tuesday,April 1,2025,01:34 PM •� ml ":7ver reen CONTHvAcROLS S CONTROLS Refrigeration &HVAC DESIGN l4� INSTALLATION a/ SERVICE Heat Pump Package Equipment (RTU) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM RTU-1 5 Ton GCQ Heat pump 460-3ph Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.79g Page 3 of 15 Unit Report For 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM Unit Parameters Dimensions(ft. in.) &Weight(lb.)*** Unit Model: 50GCQJ06B2A6-8UOAO Unit Length: 6'2.375" Unit Size: 06(5 Tons) Unit Width: 3' 10.625" Volts-Phase-Hertz: 460-3-60 Unit Hei ht: 3' 5.375" Heating Type: HeatPump R454B Total O eratin Wei ht 763 Ib R-410A SUBMITTAL Refrigerant: NOT YET Heat Control: Two Stage Cooling Models AVAILABLE Weights and Dimensions are approximate. Weight does Duct Cfg: Vertical Supply/Vertical Return not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type- Thr w w Return Air Filter Quantity: 4 Return Air Filter Size:............................._____16 x 16 x 2 Selection includes construction throwaway filter into the base fan curve. Unit Configuration RA Smoke Detector Direct Drive-EcoBlue- Medium Static AI/Cu-AI/Cu Electromechanical -can be used with POL224 EcvonomizerONE Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging Warranty Information 5-Year compressor parts(STD.) 5-Year electric heater(STD.) 1-Year parts (STD.) 3-Year SystemVu controller No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50GCQJ06B2A6-8UOAO Rooftop Unit 1 Base Unit RA Smoke Detector Direct Drive- EcoBlue-Medium Static Ultra Low Leak Temp EconomizerONE with barometric relief Field Installed Accessories CRRFCURB001A01 14-inch Tall Roof Curb 1 CRWFSTCK001A00 Wifi Stick 1 CRHEATER333AOO Electric Heater 1 Packaged Rooftop Builder 1.79g Page 4 of 15 Certified Drawing for 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM NOTES'. �r ix.S DOCUNEni IS ixE PROPER iv OF UTC CL IRATE,CONTROLS SUB ISSION OF TN ESE DRAWINGS OR DOCUMENT S Cal'{P� ixnTC IIETCOxiExiS wILLNxOiDBfPDI SCLOSEDPORS USEDNDI i]ON DOES NOT CONST]iUiE PART PERFORMANCE OR 1. DIMENSIONS ARE IN INCHES, DIMENSIONS Qur r� W wlTxouT WRITTEN CoxsenT. AcccvTAxcE of coNTAACT. IN I ] AAE IN MILLIMETERS. 2.S . CENTER OF GRAVITY UNIT 1 N CONNECTION SIZES SOGCO*04 I 73 18 5/8 E8471 14721 A 1 3/8" 1351 DIA FIELD POWER SUPPLY HOLE 3. DIRECTION OF AIR FLOW SOGCO*OS 41 3/8 18 5/8 33-3/8 11051] [472] I648] B 2" [51] DIA POWER SUPPLY KNOCKOUT 4.$ ALL VIEW DRAWN USING 3RD ANGLE 50GC0*06 41 511 18 5/8 C 1 3/4" 1441 DIA GAUGE ACCESS PLUG [1051I [472] 3p-1/q D 7/8" I221 DIA FIELD CONTROL WIRING HOLE 18171 ECONOMIZER HOOD 3/4"-14 NPT CONDENSATE DRAIN 1 OPTIONAL) 16 E I I-5/8 14073 G 2 112 " 1641 DIA POWER SUPPLY KNOCK-OUT I6521 RETURN AIR THRU-THE-BASE CHART THESE HOLES REQUIRED FOR USE CRBTMPWR 008A00, C.A00 10-7/8 ♦ THREADED WIRE REO'D HOLE 12771 RETURN CONDUIT SIZE USE SIZES IMA%.) y AIA W 112' 115V 7/8' [22.2] HORIZONTAL % 112' 24V 7/8' [22.2] CONFIGURATION Y * 3/4' IPOWER 11 1/8' I28.63 Z** (009A00) 1/2" FPT I GAS 11 118' 128.61 44-1/8 I1121I E ALT. FOR 'THRU-THE-BASEPAN' FACTORY OPTION, Y CONDENSATE it-3/4 y FITTINGS FOR ONLY%,Y, d Z ARE PROVIDED W DRAIN OPENING 1451] IN BASEPAN SUPPLY 29-1/2 SUPPLY SELECT EITHER 3/4" OR 112' AIR 26-5/a 174g1 HOR AIR AL [675] * FOR POWER, DEPENDING ON WIRE SIZE IZONT Z 14-1/2 12-1/2 11 1/2 SEE THRU THE % CONFIGURATION ** 1008A001 PROVIDES 3/4' FPT THRU CURB [369] [318] 12931 BASE CHART FLANGE d FITTING. 6-1/4 1 0-1/B 2% 23-3/4 [256] [6031 12-1/8 3-114 2%25 [307] [81] [635] F�ig-3/8 K TOP 14(1 CONDENESSTATD E 2%4-5/8 DRAIN 10-7/8 [118] 2751 ELECTRICAL [25] DISCONNECT LOCATION ' CONDENSER CONTROL BO% COIL OPTIONAL ACCESS PANEL INDOOR BLOWER 25-3/4 y OPTIONAL A,B,G FACTORY ACCESS 17-3/8 11131 O710NNL FACTOR INSTALLED I441] RETURN ECONON®i N1000 INSTALLED DISCONNECT SUPPLY AIR AIR OUTSIDE CONVENIENCE AIR OUTLET D 11-7/8 19-1/2 [302] 21-1/4 6-5/8 E494] 15391 0 I I [168] 1 I I I 1 0 FILTER 3-3/4 — 46-5/8 HANCLL HANDLE 4 6-3/B 7 5-3/4 [95] [1186] 74-3/8 [146] [161] [177] [146] 26RE -7/8 BAROMETRIC LEFT east 82 I1 FLOWEF 17861 FRONT RETURN SUPPLY AIR AIR V CONFIGURATION ERTICAL VERTICAL CONFIGURATION O RIGHT ITC CLASSIFICATION SHEET3 08/15/DATE 1 SUPERCEDES U.S. ECC N:NSR 1 OF REV 506CO 04-06 SINGLE PACKAGE HEAT PUMP 48TC003351 _ 9 - Packaged Rooftop Builder 1.79g Page 5 of 15 Certified Drawing for 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM THIS DOCUMCNT IS THE PROPERTY OE OTC CLIMATE,CONTROLS SUBMISSION OF THESE DRAWINGS NDS OR DOCNME NTS C![TT�CT d SECURITY AND IS DELIVERED OPON THE EMPA[SS CONDITION GOES NOT CONS THESE RAWT PERFORMANCE OR STD. UNIT CORNER CORNEReWE'16H'T"1C1 CORNER THAT THE CONTINTI WILL NOT 11 DISCLOSED OR ISEI ACCEPTANCE OF CONINACT. UNIT WEIGHT+ WEIGHT (A1 WEIGHT IB1 WEIGHT (D) C.G. HEIGHT Cny-y�wrtxouT xflITTEx coxsexT. LBS. KG. LBS. KG. LBS. KG. LBS. KG. x Y506CO-04 475 215 128 58 120 54 117 53 36 19141 22 3/8 15681SOGC0+05147 67 148 67 35 3/8 I898I 22 5/16 I557150GC0+O6 596 270 163 74 148 67 149 68 35 3/8 18981 22 5/16 [5571 i6 1/2 [419] , STANDARD UNIT WEIGHT IS WITHOUT ELECTRIC HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES REFER TO THE PRODUCT DATA CATALOG. BACK WITH ECNOMIZER CORNER A CORNER B A38-1/8 [968] O BACK WITHOUT ECONOMIZER ECONOMIZER HOOD (OPTIONAL) OPTIONAL DOOR SWING x Q Y LEFT ' CORNER D CORNER C RIGHT X TOP FRONT NOTE: FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. CLEARANCE Z SERVICE WITH: SERVICE WITH: OPERATING SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE ® FRONT 48 [1219mm] 36 I914mm1 18 1457mm] LEFT 48 [1219mml 42 [1067mm[ 18 [457mm] I 0 Q Q I BACK W/0 ECON 48 11219mm1 42 [1067mm] 18 1457mm] BACK W/ECON 36 [914mm[ 36 [914mml 18 [457mm] FRONT RIGHT 36 [914mm] 36 1914mml 18 [457mm] TOP 72 [1829mml 72 [1829mm[ 72 [1829mm[ ITC CLASSIFICATION SHEET DATE SUPERCEDES REV S OGCO 04-06 SINGLE PACKAGE NEAT PUMP 48TC003351 _ U.S. ECC N:NSR 2 OF 3 08/15/19 Packaged Rooftop Builder 1.79g Page 6 of 15 Certified Drawing for 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM THIS DOCUMENT IS THE PROPERTY OE OTC CLIMATE,CONTROLS SOW MISSION OF THESE DRAWINGS NDS OR DOCNME NTS C![TT�CT d SECURITY AND IS DELIVERED UPON IIF EN PA[SS CONDITION GOES NOT CONSTITUTE RAWT PERFORMANCE OR Ofl THAT THE CONTENTS WILL NOT WE DISCLOSED OR USED ACCEPTANCE Of CONIRACT. o lMlr nol��WITHOUT WRITTEN CONSENT. (INSIDE THE BASEASE RAIL 8 SKIRT) 2-114 1571 2X 14 6]3/4 [ L/ 41-1/4 O 2z 1 [1o4n 1253 (INSIDE THE p BASERAILS) O3-1/4 21 3/I 823 36][18I 2z 1-3/8 [ 3-7/8 E993 INSIDE BASERAIL DIMENSIONS DETAIL C BOTTOM TYP 4 PLCS FILTER ACCESSPANEL CONDENSER e CONTROL BOX INDOOR BLOWER (TOOL—LES 1) pCOC E85 COIL COONDENSER ACCESS PANEL ACCESS PANEL IL PANEL O INDOOR COIL ACCESS PANEL .�. SEE DETAIL C 47.6] 7 1 I ICI 1 00 LEFT BACK 2-3/8 182 OI 11509.01 7-1/8 TYP [180.7I CURB FRONT WIDTH ITC CLASSIFICATION SHEET DATE SUPERCEDES REV S OGCO 04-06 SINGLE PACKAGE NEAT PUMP 48TC003351 _ U.S. EGG N:NSR 3 OF 3 08/15/19 Packaged Rooftop Builder 1.79g Page 7 of 15 Certified Drawing for 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM 8 7 6 5 4 3 2 1 ROOFOUFB NDIN POWERVIAMNG CONTROLWIRING ACCESSORYCONVENIENCE ACCESSORY# A 1�PPEDDISPSSQvEL® CgJFECTDRR(GPL:C. GASCONNECTIONttPE GASFITTING FITTING FITTING OURETWIRINGCOMECTOR 2.INSULATEDPANELS:25.4[1']THK.POLYURETHANEFOAM,44.5[1-N4]#DENSITY. CRRFWFJWA01 14" 3.DIMENSIONSIN[]AREINMILUMETERS. CF4PNFVVFWA01 THRUIHECLRB 314"[19]NPT [356] 4.ROOFCUFR18GAGESTEEL 3/4"[19]NPT 12"[12.7JNPT 12"[12.7]NPT 5AT 7rHDUGTWbWROCURB.(FLW GESOFD JOTRESTONCURB} CRRFWRBJWlvJt [610] 6SERVICECLEARANCE4FEErONEACHSIDE CR6RV WRDO 01 THRUTHEBOTTOM 12"[12.7]NPT 7.EMeECTIONOFARFLOW. &Cf.MNEC ORPAC AGECRBTAR RVA01 ISFORIHFUTFE-OUFWASTYPE P pffiTAPVVR703AD1EFORTFRI}THE-BOTiOMTYPEGASCON ECTIONS D 134" 1 [44.5] 1.00" 5.42" 11.96" [25.4] 113/4"[298.5]WIDE [137.71 [303.8] INSULATEDDECKPANELS W. z1.Ta° [552.21 89/16"[217.51WIDE INSLLATEDDECKPANEL N 13/4" [44.4] SECTION EE 1'4-13116" NCTE72 C 496�� PLATE [427]INSIDE [126.01 [1800.' SCALEO250 DTMFUTHEECLIRB [11 6 2"[50.8]aQ ASSEMBLV(IF REQUIRED) REUM (SEENOTE#8) OPEMNG 15.19" 0104144.51 [385.8] E E 3.00' 21.84' [76.2] [554.71 L J 32.19" [817.61 \AEW7' CORNERDEfAL 14.00" SIPPLYPIR 16.2] / SUPPLVAIR REIURNPR /`F 13/4 [355.6] Opp,, I407.2] .1( [44.41 13�4" 44.51 B 1.75" [44.5] 20A1" 3.00" GAg4=T NIT nAn [518.3] r/6.2] (SUPPLIEDWTTHCURB) 0] L(FIELDSUPPUED) 5,7-W 40.3. TYPICAL(4)SIDES [1711.3] [1033.5] (FIELDSUPPLIEDD) 7/16" [11] 3A W16" NTFRFLASHING [944.6] (FIELDSUPPLIED) ROOFINGFELT SEEMENPB" �(FIELDSUPPLIED) G ia P WT P+A (RELDSUPPLIED) [nssl O - OOFINGMATERIPLa '� Cemer srrsncuse nr. \- (FIELDSUPPLIED) wffi]TIEbt�ID �i.ns.e.A Trralwaae � PR]fi,TCN TpHYNb�At r��s E�rA�or�E��FORManoN co Jpj�� I 1 30EC NJG iSaR nRvrOCaRRi[R cORaORnn0 A "V Q2 hwlaWL } t } }= w Hs o�wRrr:r_�n�rHoaiinrio of FUCF L�j�a wnnrsATpNuxt$E TmE ur aRLY/�R RERFTINR IGIDINSULATION - 1041738 Y (FIELDSUPPUED) - B MWIFACRIRNC 004-007 BfB"HJIS - � 6WNANGIJU,EER REV OVERALLDIM.5'-73/8"WASS'-77/8;18GA T-005,Y-002 �FI� 48T 7 B A MATERLALWAI6GA;NAILFIELDSUPPLIEDWAS O422/13 MvL - - 1067898 MU 0611711, - - D sgTS.F WTTHCURB 9fFM6NSi M2ilR"Fi hxua QJTT3C4<LL6-ECf 0 NJ(R1RAlMJG 9 o66ZB.nICN fEV OVE 8Y CHKD PR'D ECTlJJ. PlRf7i WA MU Packaged Rooftop Builder 1.79g Page 8 of 15 Performance Summary For 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM Part Number:50GCQJ06B2A6-8UOAO Refrigerant: R-410A ARI SEER2: 16.00 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Operating Weight Base Unit Weight: 596 lb RA Smoke Detector: 7 lb Temp Ultra Low Leak Economizer w/Baro Relief: 35 lb Accessories 14-inch Tall Roof Curb: 115 lb Electric Heater: 10 lb Total Operating Weight: 763 lb Unit Unit Voltage-Phase-Hertz: 460-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 2000 CFM Site Altitude: 449 ft Cooling Performance Condenser Entering Air DB: 85.0 F Evaporator Entering Air DB: 77.9 F Evaporator Entering Air WB: 64.2 F Entering Air Enthalpy: 29.54 BTU/Ib Evaporator Leaving Air DB: 54.5 F Evaporator Leaving Air WB: 53.7 F Evaporator Leaving Air Enthal 22.54 BTU/Ib Gross Cooling Capacity: 61.93 MBH Gross Sensible Capacity: 49.69 MBH Compressor Power Input: 3.72 kW Coil Bypass Factor: 0.027 Mixed Air Outdoor Air Airflow: 420 CFM Outdoor Air DB: 85.0 F Outdoor Air WB: 65.0 F Outdoor Air Htg. Temp.: 23.0 F Return Air DB: 76.0 F Return Air WB: 64.0 F Return Air Htg. Temp.: 70.0 F Heating Performance Outdoor Ambient Temperature: 47.0 F Entering Air Indoor Coil DB: 60.1 F Leavina Air Indoor Coil DB: 87.0 F Total Heating Capacity: 57.04 MBH Integrated Heating Capacity: 57.04 MBH Heating Power Input: 3.11 kW High Temperature COP: 3.80 Low Temperature COP: 2.70 HSPF: 8.9 High Temperature COP2: 3.70 Packaged Rooftop Builder 1.79g Page 9 of 15 Performance Summary For 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM HSPF2: 7.5 Electric Heating Capacity: 5.50 kW Unit Leaving 7 it emp: 90.11 Suppiv Fan External Static Pressure: 1.00 in wg p ions ccessories Static Pressure Electric Heaters: 0.23 in wg Economizer: 0.12 in wg Application External Static(ESP + Unit Opts/Acc.): 1.35 in wg Fan RPM: 2245 Fan Power: 1.19 BHP Selected 11-M-RIPIWanger Selection includes construction throwaway filter into the base fan curve.This filter is not MERV Rated. Electrical Data Voltage Range: 414-506 Compressor#1 RLA: 8 Compressor#1 LRA: 55 Actual Electric Heater kW: 5.5 Electric Heater FLA: 7.2 Indoor Fan Motor Type: MED Indoor Fan Motor FLA(Total): 2.1 Power Supply MCA: 22 Power Supply MOCP (Fuse or HACR): 25 Disconnect Size FLA: 21 Disconnect Size LRA: 65 Electrical Convenience Outlet: None Outdoor Fan [Qty/FLA(ea)]: 1 /0.8 Electric Heater Part Number: 333A Electric Heater Number of Stages: 1 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 94.7 90.8 85.6 125 Hz 86.2 82.2 84.7 250 Hz 80.3 73.8 80.5 500 Hz 76.0 69.1 76.0 1000 Hz 73.2 70.6 72.4 2000 Hz 71.0 62.3 68.0 4000 Hz 66.2 55.3 62.8 8000 Hz 61.7 49.2 59.3 A-Weighted 79.8 74.5 79.0 Advanced Acoustics ' 3 Page 10 of 15 Performance Summary For 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 Ilk 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 L D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.79g Page 11 of 15 Performance Summary For 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM FanCurve zo OOffM\210 IM aum FFM 270CFFM 2EODF;FM 18 V- 1 M\" 7F"-� z 16 1�M N \\ I 1.4 ODBHP c .=12 � 1D ^L LL 77 sc U � \ .50BHP Q4 02- 0. BHP 0.75 H 1 OD- \ 00 02 04 06 08 10 12 1.4 16 18 20 22 24 26 28 30 Airflow(CFM-thousands) RPM=2245 BHP=1.19 MaximtnnRPM=2836 MaximumBHP=3.00 SC-SystemCutve RP-RatedPoint Packaged Rooftop Builder 1.79g Page 12 of 15 Unit Feature Sheet for 5 Ton GCQ Heat pump 460-3ph Project: Northsound Logistics 02/05/2025 Prepared By: 05:57AM WeatherMaster with.-c blue'technology 17SEFRP IPUMPL TS UpTo16.OSEER2,17.OSEER-3,4,5TONS WeateNbsb-501313QUnits PERFO�EATURES(mnfiuo 5000Qunilsarehigheffident§rig6pad<agedheatpump Sbndard000lingoperrati mrgeupb125 lF(52 1qand unilsthatareprewiredandpre-ctxargedwtlhPumr®R(R dowlib40 lF(4 LC).LowAmbientalbwsoodingoperation 410A)HFCrefrigerantTheunifsarefadorytestedinbdh damto-20 T(29 LC) heatingandcoolingmodes ModelshaveMosbgesof Ratedinacmrdara.-vAhAl-IRIStandards210240 cooling capadlycontrol. • DesignedinaocarlancewitliUixJermrciterse Laboratories Shandard1995 ListedbyULandCUL-Canada - - MAINTENANCEFEATURES u �. "� r Aocesspanelswitlieasygriphandles Innovafive,easystarting,no-sbipsaewteatureonunk a-q-iels �e _ t Two-inchdisposableretumairfilters �- TooHessfilteramessdoor NewUnitContrd boardfadlitating simplesafetydreuk Imubleshootirigandsimplifiedoontrdboxarrangernent INSTALLAl10NFEATURES AS H RA FieldConvertblefromverdcaltohor¢ontalairflow configurationonallmodels.NospedalkbNuired. Provisionsforthru-the-bottompowerentrycapatiilki Singlepcintelecbicoonrrectiom COMPLIANT Nron• Fullperimeterbaserailwilhbuik�nriggingadaptemand forktrud<slots Twostage000lingtoniostatrequiredandprovidegreat energyandcornfo tsdutions. STANDARDLIMITEDPARTSWARRANTY 5-yearoompressorparts 5-yearelectricheater use of me nHRi camffetl 3-yearSystemVu" controller TM Mark Ineicatas a 1-yearparts manufacturer's participation in the program For verification AVAILABLEOPTIONS: of certification for individual C US RTU-OpenMulli-protocd DirectD' bIContrd(DDC) pr�tlucts,u to anntliredory.org. systemavallable ThroL ghthebaseconnedxmfbrdechcava lableas option PERFOWANC'.EFEATURES Disoar>edandmnvene)ceoutletopbons Puron(R-410A)HFCrefigerant Mulfistaticindoa-fanmotorsystems MeetsandexceedsASHRAE90.1 energyetTiaency Smokedetedor,suppyardiorrehum levels Camsionmsistantoptior evapaatoran mxlar ser Two-stageeoolingcapac ycontrol coils SEER supto17.0andHSPFupto8.9 CO2Saw SEER2-1supb16.0andHSPF2rpb7.5 PhaseMonibrProtection Soundlevetsasbnras76d6 MERV-13Flters Exdusivenon-mrrosivemmpositeoonderisatepansin LavAmbia tOperationCatals aooxdarcewtiASHRAE62Sbndard,slcongd ; Hingedaooesspaneis sideorcenterdrain Integratedemrromoarsystem.LowaridULTRALav Pre-paintedexbdorpanelsandpiimer coatedinterior Leakversions panelstestedto500hourssaltspiaypmtecbon Caxleiisaboverbhswith TXVrefrigerantmeteringsystem SystemVuc Cols Direct DriveEcoBlue" Techndogylndoorfansystem usesVaneAbdalfandesignandebctronicaly commulatedmotor. NewUnkCon*dBoard WhintuWequid<fanspeed adjustinent Fulyinsulatedcabinet Packaged Rooftop Builder 1.79g Page 13 of 15 OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Energy Recovery Ventilator (ERV) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 ►i L• • RECOVERYENERGY • Job Name: System Reference: Date: GENERAL FEATURES ERV-1 Lossnay®cross-flow energy recovery core • Minimal cross contamination between entering and leaving air streams • Stand-alone remote controller(PZ-62DR-EA) • M-NET Connectivity ( External input bypass damper control • Stand alone or interlocks connects with all Mitsubishi Electric products • Four fan speeds • High efficiency DC Motor • Standard MERV 7 non-woven fabric filter,washable fiber • Optional high-efficiency MERV 14 and MERV 16 filters Specifications System Unit Type 0O Capacity CFM[m'/h] 300[510] Power source 208/230,1,60 Power Consumption kW 0.111-0.235 Current A 0.017/0.048 Starting Current A 6.1 MCA A 4.3 Maximum Overcurrent Protection(MOCP) A 15 Air Volume CFM[m3/h] 300-225-150-127[510-382-225-75 Fan Type x quantity 8-3/4 In.diameter centrifugal fan External Static pressure in.WG 0.06-0.25-0.56-1.0 Motor type EC Motor Temperature % 65.5-70-76-83 Exchange Efficiency Enthalpy Cooling % 50.0-53.5-58.0-65.0 Enthalpy Heating % 63.0-66.5-74.0-81.5 External finish Galvanized steel sheet External Dimensions In.[mm] 41-7/8 x 41-3/16 x 13-1132[1,063 x 1,046 x 331] Net weight Lbs[kg] 75[34] Energy Transfer Mechanism Lossnay®Core Heat Exchange Material Partition,spacing plate-cellulose fiber membrane Heat Exchange System Air-to-air total heat(sensible heat+latent heat)exchange,no moving parts Blower Type 8-3/4 In.diameter centrifugal fan Entering Air Temperature Operation Range •F['Cl 14 to 104[-10 to 401 Sound pressure level dB(A) 37.0-31.0-22.0-18.0 Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: 00- Wired Remote Controller Lossnay®ERV Remote Controller ❑ PZ-62DR-EA Control Interface Signal Output Terminal ❑ PZ-4GS-E Duct Accessories Duct Silencer ❑ PZ-200SS-E MERV 14 Filter ❑ PZ-50RFP-E Filter MERV 16 Filter ❑ PZ-50RFP2-E MERV 7 Filter(Included) ❑ PZ-50RF9-E Remote Sensor CO2 Sensor,Built-In ❑ PZ-70CSB-E CO2 Sensor,Wall Mount ❑ PZ-70GSW-E Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: II ' Air exhaust fan Position where duct direction change is Possible By-pass damper plate 4 1/2' (875 Ceiling suspension fixture u-) (4-9/16'X13/16' (4-15xHlovah _3 11/32' (85) EA _ ��I��, RA (exhaust air outlet ) ~ Illii° iil � — ~ (return air) I II II I I } IIII III IIIII LL7CO Lo `� � lli �i I II III III III II irT�il o o �i�Iit V 1 II II II L l ll� 111 IIII — o M—- i�l' 4'lll'IU J Ulllll' Ili'I co Lo r- L7 III III III IIIuI -1 N � 7I IIII III III Ilf I � � IIII III III IIII I M 0A III III IIII III IIII _ SA (outside air i ntake) b illli iilii illi \\ b (supply air) it q Core, o a 3 11/32' (8 ) L- air filter, CO `o Inspection Air Supply fan 1 3/16' (30) High-Efficiency filter, �N 1p5x1ng 1 5ft fan, �c 1.50X4501 Control box 13 1/32' (331) maintenance space d N � $ "` or more Maintenance cover Power Supply cable opening a 7/8' (124) High-Efficiency filter (sold separately) Lossnay core 34 15/16' attachment Position 3 1/8' (79) (888) 3 1/8' (79) 0HIL" LD co M N Air filterscD N 6 9 Position where duct direction change is Possible c1 co L_ Co a g UNIT SCALE 4�- inch(mm) N.T.S 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA uS FORM#LGH-F300RVX2-E-202203 1 Intertek Specifications are subject to change without notice. ©2022 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Rooftop Exhaust Fans (REF) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 LMGREENHECK REF 1-4 Printed Date: 03/28/2025 Job: Northsound Logistics Building Value in Air. Mark: 2850CFM REF (Belt) Model: GB-160-7 Model: GB-160-7 028.40 Belt Drive Centrifugal Roof Exhaust Fan 23.80 Dimensional 175 35.80 Quantity 4 Weight w/o Acc's(lb) 70 (12.00) Weight w/Acc's(lb) 78 Weight w/Acc's and Curb(lb) 97 Max T Motor Frame Size 145 Standard Curb Cap Size(in.) 22 x 22 22.00 SQ Roof Opening(in.) 18.5 x 18.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. Performance Requested Volume(CFM) 2,850 1.0 0.5 Actual Volume(CFM) 2,850 �2r FRpM Total External SP(in.wg) 0.125 Fan RPM 1021 0.8 0.4 Operating Power(hp) 0.44 Elevation(ft) 30 a' Airstream Temp.(F) 70 0.6 0.3 a Air Density(lb/ft3) 0.075 a� Drive Loss(%) 8.9 ` Tip Speed(ft/min) 4,445 0.4 aa0a 0.2 cu a. Static Eff.(%) 14 Misc Fan Data fn 0.2 �� 0.1 Fan Energy Index(FEI) - oQ Outlet Velocity(ft/min) 1,549 0� o g stem.._.._............._.. ...... .... ._.. 0.0 0.0 Motor 0 4 8 12 16 20 24 28 32 Motor Included Yes Volume (CFM)x 100 Size(hp) 3/4 Voltage/Cycle/Phase 460/60/3 G Operating Bhp point Enclosure ODP O Operating point at Total External SP Fan curve Motor RPM 1725 - - ---System curve Efficiency Rating Standard ------- Brake horsepower curve Windings 1 NEC FLA (Amps) 1.6 Min.Circuit Ampacity(MCA) 2 Notes: Max.Overcurrent Protection(MOP) 15 All dimensions shown are in units of in. *NEC FLA,MCA and MOP are for reference only—based on Short Circuit Current Rtg(SCCR) 5 kA tables 430.248 or 430.25 of National Electric Code 2020.Actual motor FLA may vary,for sizing thermal overload,consult factory. VRRTInGS MCA and MOP values shown only account for the motor,not accessories(damper actuator,field supplied VFD,etc). SOU11Lj POWOT b Octave B111Ci LwA-Aweighted sound power level,based on ANSI S1.4 y dBA-A weighted sound pressure level,based on 11.5 dBSound attenuation per Octave band at 5 ft-dBA levels are not licensed Data 62.5 125 250 500 1000 2000 4000 8000 LWA dBA Sones byAMCAInternational rEwop Sones-calculated using ANSI/AMCA 301 at 5 ft Inlet 75 1 79 81 1 71 67 65 60 54 76 64 13.4 The motor provided on this fan is inverter ready and meets NEMA MG1 Part 31.4.4.2 \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 1 of 11 LNGREENHECK Printed Date: 03/28/2025 Job: Northsound Logistics Building Value in Air. Mark: 2850CFM REF (Belt) Model: GB-160-7 Model: GB-160-7 Belt Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined aluminum wheel-Curb cap with prepunched mounting holes-Motor and drives isolated on shock mounts- Birdscreen-Ball bearing motors-Adjustable motor pulley-Adjustable motor plate-Fan shaft mounted in ball bearing pillow blocks-Bearings meet or exceed temperature rating of fan-Static resistant belts-Corrosion resistant fasteners- Sizes 141 and larger have internal lifting lugs. Selected Options &Accessories: Motor VFD Rated without Shaft Grounding Protection Standard Curb Cap Size-22 Square UL/cUL 705 Listed-"Power Ventilators" Switch, NEMA-1,Toggle, Junction Box Mounted&Wired in weather-protected motor compartment Foam Curb Seal(Factory Applied) Birdscreen:Galvanized,nom.84%Free Area Conduit Chase Qty 1 Unit Warranty: 1 Yr(Standard) Selected Sub Marks See individual submittals for full details GPI-22-G 12 \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 2 of 11 OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Exhaust Fans (EF) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 EF-1,2 BRa4a-4& N"" SPECIFICATION SHEET LIGHT COMMERCIAL ENERGY STAR° CERTIFIED CEILING MOUNT VENTILATORS MODELS L100E, o L150E, L200E, L250E & L300E Incredibly reliable. Unbelievably quiet. Offering the CFM TYPICAL SPECIFICATION choices you need atthe lowest sound levels in the industry. Ventilator shall be Broan Model L100E, (1-150E), (L200E), FEATURES (L250E), (L300E). GRILLE: Ventilator shall have galvanized steel housing insulated with • Conceals interior at least 1/2"of acoustic insulation.Housing to have adjustable • Low profile styling blends with any decor mounting brackets. • White plastic(optional metal grille,finished with white Automatic backdraft damper to be located within duct enamel paint is available- Model MG1) connector.Duct connector,blowerassembly,and wiring plate BLOWER: shall be adjustable for either horizontal or vertical installation. • Low RPM for quiet operation Blower unit shall be removable from housing and shall have • Resilient anti vibration mounts a dynamically balanced centrifugal-type blower wheel.Motor to be permanently lubricated and mounted with resilient anti- • Dynamically-balanced, centrifugal blower wheel for vibration mounts. quiet, efficient performance Air delivery shall be no less and sound levels no greater • Permanently lubricated,thermally protected motor than listed for each model.All air and sound ratings shall be • Plug-in motor rated at 120 VAC certified by AMCA and HVI.Units to be cULus Listed. • Designed for continuous operation HOUSING: amcca • Rugged,20 gauge galvanized steel ® «ruin' • 8"round duct connector • 1/2"acoustic insulation inside H V I D :ounD • Not for use in a cooking area CERTIFIED "!R • May be installed in ceiling or wall (size permitting) • 8-position mounting brackets for easy installation and greater adaptability to various mounting requirements • Automatic backdraft damper located within duct connector r� ew, ono • Factory-shipped in horizontal discharge position -easily T. o:P oMP°w converted to vertical discharge ® zoos 2oz� zoz� ACCESSORIES (available separately): • Model MG1 Metal Grille Cover Upgrade • Model RD1 Radiation Damper • Model 80L Electronic Speed Control (Internal) C&US Broan-NuTone LLC, 926 West State Street, Hartford,Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711 Venmar Ventilation ULC,550 Lemire Blvd., Drummondville, Quebec, Canada J2C 7W9 Broan-NuTone.ca 800-567-3855 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 22 K 1108087A PERFORMANCE RATINGS -LIGHT COMMERCIAL ENERGY STAR° CERTIFIED CEILING MOUNT VENTILATORS L100E, L150E, L200E, L250E & L300E AMCA LICENSED PERFORMANCE STATIC PRESSURE(Inches water gage) MODEL NO. 0.0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875 NOMINAL MAX.AMPS AC VOLTS RPM @60 Hz CFM Hor. 164 138 132 103 74 40 SONES Hor. 0.2 0.3 0.7 803 0.3 120 L100E CFM Ver. 168 138 131 101 73 38 SONES Ver. 0.1 0.2 0.8 799 0.3 120 CFM Hor. 238 214 209 183 154 122 77 972 0.4 120 SONES Hor. 1.0 1.0 1.1 L150E CFM Ver. 224 203 198 174 146 105 64 SONES Ver. 0.9 0.9 1.0 990 0.4 120 CFM Hor. 267 246 240 214 184 155 109 56 1031 0.5 120 SONES Hor. 1.5 1.5 1.7 L200E CFM Ver. 253 233 228 202 172 123 87 41 1063 0.5 120 SONES Ver. 1.4 1.3 1.5 CFM Hor. 296 277 272 249 223 195 160 108 51 SONES Hor. 1.9 1.9 1.8 1128 0.6 120 L250E CFM Ver. 280 263 259 237 212 185 142 89 40 1144 0.6 120 SONES Ver. 1.9 1.8 1.8 CFM Hor. 343 324 319 295 268 237 204 162 89 1189 0.7 120 SONES Hor. 3.0 2.9 2.7 L300E CFM Ver. 334 315 311 286 258 227 189 150 20 1207 0.7 120 SONES Ver. 2.9 2.7 2.6 Performance ratings including the effects of inlet grille and backdraft damper in the airstream.Speed(RPM)shown is nominal.Performance is based on actual speed test.The sound ratings shown are tested to 1/3 octave,Spherical Sones to AMCA 300.Values shown are for installation Type B:Free inlet fan sone levels.Performance shown is for Installation Type B:Unducted inlet,Ducted outlet. Broan-NuTone LLC certifies HVI PERFORMANCE QmCQ thatthe modelsshown herein RTIfIED are licensed to bear the : G O I AMCA Seal. The ratings MODEL NO. Ducting 0.1"PS 0.25"Ps shown are based on tests CFM Sones CFM/Watt CFM Sones fOU11D and procedures performed in accordance with AMCA Horizontal 130 0.3 4.9 97 0.8 RIR°' Publication 211 (and AMCA L100E Publication 311 if sound is Vertical 140 0.3 5.3 101 0.6 also certified)and comply with the requirements oftheAMCA Horizontal 200 1.0 4.6 168 1.4 Certified Ratings Program. L150E lHorizontal 210 0.7 4.9 178 1.0 230 1.3 4.4 198 1.5 L200E n u� uc 240 1.0 4.6 209 1.3 y a7 270 1.5 4.5 242 2.0 L250E All models are 270 1.4 4.5 242 1.5 UL Listed for use Horizontal 310 2.5 4.2 281 2.5 over bathtubs and L300E showers when Vertical 310 2.5 4.3 282 2.5 connected to a GFCI-protected branch circuit (ceiling mount only). O t chnol gi s CERTIFIED and procedures S comply p escribedwlth by new the testing ine WEIGHT 1 Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 P40DEL NO, SHIPPING WT. 14 Vin.static pressure, based on tests conducted in a state-of-the- L100E....................................................................18.9 lb. art test laboratory.Sones are a measure of humanly-perceived CERTIFIEDloudness,based on laboratory measurements. L200E....................................................................19.1lb. L250E....................................................................21.0 lb. L300E....................................................................21.2 lb. B R A Broan-NuTone LLC,926 West State Street, Hartford,Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711 r� Venmar Ventilation ULC,550 Lemire Blvd., Drummondville,Quebec,Canada J2C 7W9 Broan-Nutone.ca 800-567-3855 PERFORMANCE CURVES - LIGHT COMMERCIAL ENERGY STAR° CERTIFIED CEILING MOUNT VENTILATORS Horizontal Ducting 1.0 0.9 0.8 0.7 — .• '�� — -- -- -- -- -- -- -- — m 0.6 -- --- - --- --- --- --- --- --- -- L300E 3 a 0.4 -- --- —' --- --- --- --- -- -- -- —L200E —L150E 0.3 -- --- --' --- --- -- --- --- -- —L100E 0.2 0.1 0.0 — 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Airflow(CFM) Vertical Ducting 1.0 0.9 0.8 0.7 - -- — —- --- --- - - - —- -- -- --- --- -- -- -- 0.6 •'T -- -- --- --- --- --- --- --- --- -- L300E 3 $ $- 0.5 - -- — __ —_ - —_ - —_ —_ —_ —_ — ......L210E a 0.4 - --- — -- -- - -- -- -- -- — —L200E - _ —L150E 0.3 —L100E 0.2 0.1 0.0 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Airflow(CFM) 0ONO S,I�OUGTfop 2� I24 S(G) ��EG CON o ELECTRONIC SPEED RADIATION DAMPER CONTROL(INTERNAL) MODEL RD1 MODEL 80L (AVAILABLE SEPARATELY) (AVAILABLE SEPARATELY) ro coMv vswnr ro�%einiv iwTM I� I� I� I� zoos zo2t zoz� 0 yl amca Damn, PLASTIC GRILLE OPTIONAL V V� rD (included with METAL GRILLE CERTIFIED AIR all models) MODEL MG1 (available separately) NOTE: Dimensions shown are in inches. BR�IV® Broan-NuTone LLC,926 West State Street, Hartford,Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711 r� Venmar Ventilation ULC,550 Lemire Blvd., Drummondville,Qu6bec,Canada J2C 7W9 Broan-Nutone.ca 800-567-3855 OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Intake Hoods (IH) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 LMGREENHECK IH-1,2 Printed Date: 03/27/2025 Job: Northsound Logistics Building Value in Air. Mark: 5700CFM IH Model: FGI Model: FGI L -� Standard Construction Features: up -Precision formed locked rib construction. -Available in aluminum or galvanized steel construction. -0.5 in.galvanized steel mesh birdscreens. -Heavy gauge c galvanized steel support members. -Hood can be removed completely from the base or hinged open.-Units with a throat size exceeding 60 in.x 120 in.will have Base Height 12 in.galvanized bases as standard.-Recommended roof opening dimension is 1,75 at least 2.5 in.larger than the damper size. TL Curb Cep Width Curb Cap Length Dimensions Throat Throat Hood Hood Hood Curb Cap Curb Cap Width Length Width Length Height Width Length Weight Ship ID# Tag Qty Model TW(in.) TL(in.) A(in.) B(in.) C(in.) (in.) (in.) (lb) Assembled 2-1 2 FGI-40x40 40 40 67 72 23 46 46 172 Yes Performance Throat Volume Throat Area Velocity ID# Tag Qty (CFM) SP(in.wg) (ft2) min) 2-1 2 5,700 0.062 11.11 513 Construction Installation Insect Base Birdscreen Unit ID# Type Screen Height(in.) Material Material 2-1 Non-Ducted No 5 Galvanized Galvanized Accessories Texas Department of Florida Insurance Hood Supply High Wind Product Miami-Dade Product Insulation Tie Down ID# Filters Rated Approval# NOA# Evaluation Curb Seal (in.) Points 2-1 No No N/A N/A N/A No None No Roof Curbs Height Width Length ID# Model (in.) (in.) (in.) 2-1 GPI 12 46 46 \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 1 of 20 LMGREENHECK Printed Date: 03/27/2025 Job: Northsound Logistics Building Value in Air. Mark: 5700CFM IH Model: GPI Actual L Actual W Model: GPI 1.75 Roof Curb Standard Construction Features: Height -Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum-Straight Sided without a cant-2 in.mounting flange-3 lb density insulation-Height-Available from 12 in.to 42 in.as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be Flan e L greater than the"Actual'top outside dimension minus 2 in.. -The minimum roof Flange W opening dimension should be at least 2.5 in.more than the damper dimension or recommended duct size.-The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension.-Damper Tray is optional and must be specified. Tray size is same as damper size.-Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. General Sizing Undersizing Weight Shipped ID# Tag Qty Model Method (in.) (lb) Assembled Union Made 2-1 2 GPI-46-G12 Nominal 1.5 44 Yes No preference Dimensions Nominal Nominal Actual Actual Curb Outside Outside Outside Outside Height Width Length Width Length ID# (in.) (in.) (in.) (in.) (in.) 2-1 12 46 46 44.5 44.5 'May not be applicable Accessories Security Insulation I Insulation ID# Material Bars Liner (in.) R Value 2-1 Galvanized No No 1 R4.3 \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 2 of 20 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Louvers (L) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 LNGREENHECK L-1 Printed Date: 03/28/2025 Job: Northsound Logistics Building Value in Air. Mark: 10000CFM Louver Model: ESD-435 ESD-435 4 in. Frame, 35 deg Blade APPLICATION & DESIGN ESD-435 is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drain gutters in the head member and horizontal blades to channel water to the jambs where water is further channeled through vertical downspouts and out at the sloped sill. The ESD-435 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence. PRODUCT DETAILS Frame: 4 in.x 0.081 in. Frame Thickness Internal View Frame Type: Channel Blades: 0.081 in.Fixed Blade Thickness Material: Aluminum Sizing: 1/4 Inch Under Shape: Rectangular Construction: Mechanically Fastened OPTIONS & ACCESSORIES Finish: Mill Bird Screen: 0.75 in.x 0.05 in.,Flat Expanded Aluminum, Internal, Mill Finish Union Label: No Preference Warranty: 1 year Standard Product Warranty SUMMARY . • TAG QTY. W(in.) H(in.) FREE AREA FREE AREA SECT WIDE SECT HIGH SHIP SECT. 12-1 1 70 70 19.67 58.2 1 1 1 PERFORMANCE ID# TAG APPLICATION VOLUME(CFM) FREE AREA PRESSURE .-.- 12-1 Intake 10,000 509 0.042 989 "Calculated pressure drop does not include the effects of screens,filters or other accessories Total Louver Qty: 1 Total Weight(lb): 118 Louver Area(ft2): 34 Total Ship Sect.: 1 —Weight shown is an estimate only based on the default base product configuration without options or accessories. Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck.Options and accessories including,but not limited to,screens,filter racks,louver doors,and blankoff panels are not subject to structural analysis unless indicated otherwise by Greenheck.Unless specifically indicated,the following are NOT included in the quote provided:structural steel,installation hardware(anchors,angle clips,continuous angles,shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation,miscellaneous flashing,trim or enclosures,blank off panels,mullion covers or mullion hardware, hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals,any applicable taxes,stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 8 of 11 LMGREENHECK Printed Date: 03/28/2025 Job: Northsound Logistics Building Value in Air. Mark: 10000CFM Louver Model: ESD-435 Louvers Product Limited Warranty Thank you for purchasing Greenheck louvers.Greenheck warrants this equipment to be free from defect in material and workmanship for a period of 1 year from the date of product shipment.Any units or parts,which prove defective during the warranty period,will be repaired,or replaced at our option when returned to our factory,transportation prepaid. Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with removal or installation of product(s). The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer.This limited warranty will be void if payment from Customer is not received within a commercially reasonable time frame.GREENHECK MAKES NO OTHER WARRANTY,EITHER EXPRESS OR IMPLIED,REGARDING ITS PRODUCTS,OR ITS SELECTION AND APPLICATION, INCLUDING,BUT NOT LIMITED TO,COMPLIANCE WITH BUILDING CODES,SAFETY CODES,LAWS,MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE.This limited warranty is extended solely to the Customer. It is nontransferable and non-assignable,and the Customer shall not permit or authorize its employees,agents,representatives, or customers to claim,represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty,Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s)replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms,unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations,including,but not limited to,those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail,postage prepaid,return receipt requested to: Greenheck,Attn: Louver Sales,525 Western Road,Schofield,WI 54476. By proceeding to use our products and services on your project,you accept the terms of these limited warranties. \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 9 of 11 LNGREENHECK Printed Date: 03/28/2025 Job: Northsound Logistics Building Value in Air. Mark: 10000CFM Louver MD Model: VCD-23 VCD-23 Low Leakage 3V Blade Volume Control Damper APPLICATION & DESIGN The VCD-23 is a ruggedly built low leakage control damper intended for applications in low to medium pressure and velocity systems. A wide range of electric actuators are available. DAMPER RATINGS Pressure: Up to 5 in.wg-pressure differential channel Frame Velocity: Up to 3,000 ft/min Leakage: Class 1A @ 1 in.wg + + Class 1 @ up to 5 in.wg Temperature: Up to 250 F PRODUCT DETAILS Frame Type: Channel Frame Thickness: 16 ga 1 1.25 in. Material: Galvanized Height max (typical) Blade Type: 3V Blade Action: Opposed Blade Seal: TPE Axle/Linkage Material: Steel Axle Bearings: Synthetic width Jamb Seal Material: Stainless Steel \ 5 in. Damper Temp.Rating: 180 F Jackshafting: No Preference Actuator Sizing: Default SgFt •This drawing shows a general damper configuration and is not intended to depict the Ext.Shaft Length: Standard(6 in.) exact configuration of all dampers in this submittal. Multi-Section Fastening: Standard •Width and height furnished approximately 0.250 in.undersize. Sizing: Nominal Factory supplied actuators are sized for 1,500 ipm and a fully-closed differential pressure of 2 in.wc.Contact factory for actuator sizing on applications exceeding those levels. ACTUATOR INFORMATION • Dampers with an entered width less than 6.125 in. and a 12 gauge frame will be undersized by 118 in. Actuator Type: 120 VAC •Installation instructions available at www.greenheck.com. Operating Mode: TwoPosition Actuator Operation: Spring Return CODES APPROVED Fail Position: Closed IECC(International Energy Conservation Code) Auxiliary Switches: No compliant Spring Return Time: Standard The AMCA Certified Ratings Seal applies to Air OPTIONS & ACCESSORIES Leakage and Air Performance ratings. Union Label: No Preference SUMMARY ID# Tag Qty I Width Height Configuration Drive Arrangement: Actuator Mounting: Actuator Location: Actuator Qty: Drive- External Right Side 1 13-1 1 70.000 in. 70.000 in. CC-21-1FER-0 Actuator Mfr: Actuator Model: Act.Orientation: Standoff Size: Belimo AFBUP Perp Down 1.500 in. \\orca\Public\Daniel T\Winjobs\Northsound Logistics.gfcj CAPS 4.46.1122 Generated by:daniel@dorse.com Page 10 of 11 OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Electric Unit Heaters (EH) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 cking EH-2,5 Electronic HeaterKB PlatinurnX Series Model Code: 'KB 48 I i - With U.S.&G16WI a fik A:Series B:20-208V, 24-240/208V SMa 27-277V, 48-480V ^ � � - St_P C:kiloWatts(3-40) uMir D:-1=Single Phase PROTECTION -3=Three Phase i 6 -3MP=1-3 Phase e@uS E:-PLTMX=Electronic Controller+24V LISTED Remote Thermostat Provision F:Fuse Block Energy-Saving PlatinumX Electronic Temperature Controller • Auto Memory Feature: Patented Smart Limit Protection® Built-In Provision for Optional 24V Remote Thermostat returns units to last settings Permanent Lubricated Unit Bearing Motor Compatible with NEST/Any 24V WIFI Stat after power outage Universal Wall/Ceiling Bracket Included Remote Control Included with Wall Holder Adjustable Louvers to Direct Air 5-Year Limited Warranty Summer Fan Only&Timer Modes Built-In Fan Delay to Dissipate Heat High Mass Steel Fin Heat Exchanger The KB PlatinumX Horizontal Unit Heater King's KB PlatinumX series unit heaters are the most full-featured unit heaters on the market,with in-built electronic thermostat for accuracy and remote control for simple operation. Comes standard with a provision for adding an optional 24V thermostat for remote temperature control. Includes integrated summer fan only and thermostat timer modes,the KB PlatinumX has you covered. Designed for use as primary or supplemental heat sources in large or exposed areas, including high-rise buildings, stores,warehouses, garages,water treatment and fire room vaults to prevent freezing.Spiral finned steel elements and high CFM ensure even air distribution producing cooler element operation, prolonging heater life. By combining the highest quality components,with a dynamically balanced fan blade,the KB PlatinumX unit heater will provide years of trouble-free service. Includes universal wall/ceiling bracket for simple installation. PlatinurnX Electronic Controller Features •Electronic control for accuracy •Thermostat timer mode(1-9 Hours) •Summer Fan only mode 0 •Large LED display 5 oP' •y > works with •Built-In fan delay m m. •Built-In provision for optional 24V remote thermostat •Remote control and wall/ceiling bracket included or Any 24V •Heaters 25kW&above are ECO2S+2-stage heaters •Compatible with NEST/any 24V WIFI Stat WIFI Stat Engineering Specifications Contractor shall supply and install KB PlatinumX Series unit heaters manufactured by King Electrical Mfg.Company.Heaters shall be of the wattage and voltage as indicated on the plans. Aluminum Fan Blade:Axial flow-type fan mounted directly to the motor shaft for Construction:All exterior and interior metal enclosure parts are made from maximum efficiency. 20 gauge electrogalvanized Steel with a rust inhibiting baked enamel finish. Thermal Overload:Heaters shall be equipped with King's patented thermal overload Smooth rounded corners and protective edge trim give an attractive modern Smart Limit Protection(5,which disconnects elements and motor in the event normal appearance. operating temperatures are exceeded.If thermal overload trips due to abnormal Electronic Control:Up,down temperature mode.Start/Stop standard on operating temperatures,thermal overload shall remain open until manually reset by all heaters.Heaters 25kW&above area ECo@s+2-Stage heaters. turning the heater off for 15 minutes.Automatically reset of thermal overloads,which Auto Memory Feature:Returns Unit To Last Settings After Power Outage. allow the element to continue to cycle under abnormal conditions,will not be accepted. Adjustable Outlet Louver:Louvers direct air up or down as needed for the Internal Controls:Magnetic contactors are standard on all 480V heaters,all heating application. 2080-Phase,240V/1-Phase,277W1-Phase heaters above 6kW,and all 3-Phase Rear Intake Screen:Heavy gauge steel screen protects against foreign heaters. objects making accidental contact with the rotating fan blade. Provision For 24V Remote Thermostat:Includes terminals to connect an optional Spiral Fin Elements:The metal sheath element is copper brazed with spiral 24V 2-Stage Thermostat.Compatible with NEST/any 24V WIFI Stat fins then molded into a coil configuration.This combination produces the best Fusing:Internal circuit fusing is provided when the heater ampacity exceeds 48 Amps heat transfer while eliminating the potential for hot spots by positioning the to comply with N.E.C.standards.A fan delay is provided standard on models 12.5-kW element in the maximum airflow stream. and above to dissipate residual heat from the heating elements. Totally Enclosed Fan Motor:Permanently lubricated long life,unit bearing Easy Installation:A quick access panel located on the bottom of the heater allows with 20cc of oil.Epoxy-coated motor with enclosed rotor resists moisture and for quick wiring and easy maintenance for the life of the heater.Includes universal corrosion for long-lasting,trouble-free operation. wall/ceiling bracket for simple installation. Approvals:cULus(E41422) King Electrical Manufacturing Company 91311Oth Avenue South, 98108 phone 206.762.0400 fax 206.763.7738r chiking Electronic Unit HeaterKB PlafinumX Serip(z Ordering Information - single phase _ MODEL UPC KW BTUH PHASE VOLTS AMPS MOTOR CFM TEMP. AIR MAX. *SIZE WT. (000) HP RISE THROW MOUNT (Ibs.) HEIGHT KB2003-1-PLTMX 33188 3.3 11.3 1 208 15.9 16W** 520 20° 15ft. 8ft. A 30.5 KB2004-1-PLTMX 33191 4 13.7 1 208 19.2 16W** 520 24' 15ft. 8ft. A 30.5 KB2005-1-PLTMX 33194 5 17.1 1 208 24.0 16W** 520 300 15ft. 8ft. A 30.5 208V KB2007-1-PLTMX 33197 7.5 25.6 1 208 36.1 25W** 690 340 20ft. 9ft. B 45.0 KB2010-1-PLTMX 33200 9.98 34.1 1 208 48.0 35W** 800 39' 24ft. 1Oft. B 45.0 KB2012-1-PLTMX-FB 33221 12.5 42.7 1 208 60.1 50W** 935 42' 28ft. lift. C 50.0 KB2015-1-PLTMX-FB 33223 15 1 51.2 1 208 72.1 50W 1050 45' 33ft. 12ft. C 50.0 KB2403-1-PLTMX 33189 3.3 11.3 1 240/208* 13.8/11.9* 9W 520 20' 15ft. 8ft. A 30.5 KB2404-1-PLTMX 33192 4 13.5 1 240/208* 16.7/14.4* 9W 520 24' 15ft. 8ft. A 30.5 KB2405-1-PLTMX 33195 5 17 1 240/208* 20.8/18* 9W 520 300 15ft. 8ft. A 30.5 240V KB2407-1-PLTMX 33198 7.5 25.6 1 240/208* 31.3/27* 16W 690 340 20ft. 9ft. B 45.0 KB2410-1-PLTMX 33201 10 34.1 1 240/208* 41.7/36.1* 16W 800 40' 24ft. 1Oft. B 45.0 KB2412-1-PLTMX-FB 33222 12.5 42.7 1 240/208* 52.1/45.1* 35W 935 42' 28ft. lift. C 50.0 KB2415-1-PLTMX-FB 33224 15 1 51.2 1 1 240/208* 62.5/54.1* 50W 1050 45° 33ft. 12ft. C 50.0 KB2703-1-PLTMX 33190 3 10.2 1 277 10.8 9W 520 18' 15ft. 8ft. A 30.5 KB2704-1-PLTMX 33193 4 13.5 1 277 14.4 9W 520 24' 15ft. 8ft. A 30.5 277V KB2705-1-PLTMX 33196 5 17 1 277 18.1 9W 520 300 15ft. 8ft. A 30.5 KB2707-1-PLTMX 33199 7.5 25.6 1 277 27.1 16W 690 34' 20ft. 9ft. B 45.0 KB2710-1-PLTMX 33202 10 34.1 1 277 36.1 25W 800 1 40' 24ft. 1Oft. B 45.0 *Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V.**240V motor deratetl for 208V operation. Ordering Informatir three phase MODEL UPC KW BTUH PHASE VOLTS AMPS MOTOR CFM TEMP. AIR MAX. *SIZE WT. (000) HP RISE THROW MOUNT (Ibs.) HEIGHT KB2012-3-PLTMX 33211 12.5 42.7 3 208 34.7 50W** 935 42° 31ft. 12ft. C 50.0 KB2015-3-PLTMX 33213 15 51.2 3 208 41.6 50W 1050 450 33ft. 13ft. C 50.0 208V KB2020-3-PLTMX-FB 33225 20 68.3 3 208 55.5 1/4 HP 1750 36* 37ft. 14ft. E 60.0 KB2025-3-PLTMX-FB 33228 25 85.3 3 208 69.4 2 50W** 1870 42° 39ft. 15ft. F 85.0 KB2030-3-PLTMX-FB 33230 30 102.4 3 208 83.2 2 50W 2100 45° 41ft. 17ft. F 85.0 KB2412-3-PLTMX 33212 12.5 42.7 3 240/208* 30.1/26* 35W 935 42' 31ft. 12ft. C 50.0 KB2415-3-PLTMX 33214 15 51.2 3 240/208* 36.1/31.2* 50W 1050 45' 33ft. 13ft. C 50.0 KB2420-3-PLTMX-FB 33226 20 68.3 3 240/208* 48.1/41.6* 1/4 HP 1750 360 37ft. 14ft. E 60.0 240V KB2425-3-PLTMX-FB 33229 25 85.3 3 240/208* 60.1/52.0* (2)35W 1870 42° 39ft. 15ft. F 85.0 KB2430-3-PLTMX-FB 33231 30 102.4 3 240/208* 72.1/62.4* (2)50W 2100 45° 41ft. 17ft. F 85.0 KB2440-3-PLTMX-FB 33232 40 136.5 3 240/208* 96.2/83.2* (2)1/4 HP 3500 36° 43ft. 19ft. F 100.0 KB4820-3-PLTMX 33227 20 68.3 3 480 24.0 1/4 HP 1750 36* 37ft. 14ft. E 60.0 KB4825-3-PLTMX 33233 25 85.3 3 480 30.1 (2)35W 1870 42° 39ft. 15ft. F 85.0 480V KB4830-3-PLTMX 33234 30 102.4 3 480 36.1 (2)50W 2100 45° 41ft. 17ft. F 85.0 KB4840-3-PLTMX-FB 33235 40 136.5 3 480 48.1 (2)1/4 HP 3500 36° 43ft. 19ft. G 100.0 *Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V.**240V motor deratetl for 208V operation. chiking Electronic Unit HeaterKB PlatinurnX Series Ordering Informatie• multi-phase MODEL UPC KW BTUH PHASE VOLTS AMPS MOTOR CFM TEMP. AIR MAX. *SIZE WT. (000) HP RISE THROW MOUNT (Ibs.) HEIGHT KB2003-3MP-PLTMX 33203 3 10.2 1-3 208 14.4/8.3 16W** 520 18° 20ft. 8ft. C 45.0 208V KB2005-3MP-PLTMX 33205 5 17.1 1-3 208 24&13.9 16W** 520 30' 20ft. 8ft. C 45.0 KB2007-3MP-PLTMX 33207 7.5 25.6 1-3 208 36.1 &20.8 25W** 690 340 24ft. 9ft. C 46.5 KB2010-3MP-PLTMX 33210 9.98 34.1 1-3 208 48/27.7 35W** 800 390 29ft. lift, C 46.5 KB2403-3MP-PLTMX 33204 3 10.2 1-3 240/208* 12.5/7.2*&10.8/6.2* 9W 520 18' 20ft. 8ft, C 45.0 240V KB2405-3MP-PLTMX 33206 5 17.1 1-3 240/208* 20.8/18*&18/15.6* 9W 520 30' 20ft. 8ft. C 45.0 KB2407-3MP-PLTMX 33208 7.5 25.6 1-3 240/208* 31.2/27*&18/15.6* 16W 690 34' 24ft. 9ft. C 46.5 KB2410-3MP-PLTMX 33209 1 10 34.1 1 1-3 240/208* 41.7/36.1*&24.1/20.8* 25W 800 40' 29ft. lift. C 46.5 KB4803-3MP-PLTMX 33215 3 10.2 1-3 480 6.3/3.6 9W 520 18' 20ft. 8ft. C 45.0 480V KB4805-3MP-PLTMX 33216 5 17.1 1-3 480 10.4&6.0 9W 520 300 20ft. 8ft. C 45.0 KB4807-3MP-PLTMX 33217 7.5 25.6 1-3 480 15.6/9 16W 690 340 24ft, 9ft. C 46.5 KB4810-3MP-PLTMX 33218 10 34.1 1-3 480 20.8&12 25W 800 40' 29ft. lift. C 46.5 KB4812-3MP-PLTMX 33219 12.5 42.7 1-3 480 26&15 35W 935 42' 31ft. 12ft. C 50.0 KB4815-3MP-PLTMX 33220 15 51.2 1-3 480 31.3&18.1 50W 1050 45* 33ft. 13ft. C 50.0 *Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V.**240V motor derated for 208V operation. Field Mount Options ADD SUFFIX: UPC DESCRIPTION WT.(lbs.) DS32 13480 Disconnect Switch,Field Installed Kit,32 AMP,600V 2.0 DS63 13481 Disconnect Switch,Field Installed Kit,63 AMP,600V 2.0 DS80 13482 Disconnect Switch,Field Installed Kit,80 AMP,600V 2.0 DS100 13483 Disconnect Switch,Field Installed Kit,100 AMP,600V 5.0 Replacement Accessories MODEL UPC DESCRIPTION WT.(Ibs.) ECO2S-REMOTE 33489 ECO2S Replacement Infrared Remote Control 0.1 ECO2S-REMOTE-BRACKET 33490 ECO2S Replacement Infrared Remote Control Wall Mount Bracket .04 KBB-1 13484 Replacement Universal Wall/Ceiling Small Mounting Bracket(for heaters with size A heaters) 1.9 KBB-2 13485 Replacement Universal Wall/Ceiling Large Mounting Bracket(for heaters with size B and C) 2.6 KBB-3 13488 Replacement Universal Wall/Ceiling Large Mounting Bracket(for heaters with size F&G) 3.9 KBHS 13486 Replacement Hook Swivel 0.4 KBHK 13487 Replacement Hardware Kit 0.1 Rracket Selection Chart HEATER KW SIZE BRACKET DIMENSIONS BRACKET# USED WITH L W H A B C D E F X Y Z KBB-1 3 to 5 kW(1 phase) 12%2" 215/16" 101/16" 13/16" 7" 17/8" 17/8" 91/4" 17/8.. 3/a" 1" %2" KBB 2 7.5 to 10 kW(1 phase) 167/8" 215/16" 101/8" 11/4 7" 17/8" 15/8" 135/8" 15/8" 3/4" 1" 1%2" 3 to 20 kW(3 phase) KBB-3 25 to 40 kW(3 phase) 19%2" 43/16" 133/16" 15/16" 10" 17/8" 15/8" 161/4" 11/8" 11/16" 1" 2" CompanyKing Electrical Manufacturing 91311Oth Avenue South,Seattle,WA 98108 phone 206.762.0400 fax 206.763.7738 king Electronic Unit Heater KB PlatinumX Series Dimensional Data IF Double Unit Size F&G/ . L E Pearance mill��tsx� D C H B L A Y Height HEATER x Z X SIZE HEIGHT DEPTH WIDTH W A 16.5" ill, 15y' B 16.5 13.5" 15" KBB-1,KBB-2&KBB-3 - Unit heater brackets can be used for mounting C 16.5" 18" 15" /ZDepth on ceiling or wall.3/8"threaded hole on top of E 20.5" 23.8yy 15y' Width ---------- unit heater can also be used with threaded rod IF 18.5 18" 30 to drop the unit closer to the floor G 20.5" 23.8" 30" Refer to bracket selection chart. King Electrical Manufacturing Company 9131 1 Oth Avenue South,Seattle,WA 98108 phone 206.762.0400 fax 206.763.7738 www.king-electric.com chiking sssissssfisaEH-1 ,3,4,E q Air Velocity Heater KFUH ECO2SSeries Model KFUH 24 1 Shown with KFUH DIFFUSER. A:Series KFUH DIFFUSER 42' B:20-208V 24-240v required for this heater and is C:Kilowatts sold separately D:1 or 3-phase E:2-Stage heating F:Energy efficient motor(ECM) 4 1 C UL US LISTED ass , A ■Energy efficient ECM motor • Direct drive air over type motor ■ Ductable on intake and outlet as 2-Stage Energy-Saving Heating** ■ Adjustable louver hood(sold separately) ■ Fan-only relay ■Heavy duty open coil element ■ Quiet switching relays ■ 5 speeds ■Dual inlet industrial blower ■ Replaceable intake filter ■ 5-year limited warranty With U.S.&Global Materials as Horizontal or vertical mount ■ 24 Volt control The KFUH ECO2S High Air Velocity Unit Heater ENERGY SAVINGS meets MAXIMUM COMFORT with the ECM Motor&2-Stage Heating** The KFUH ECO2S Model adds a state of the art electronically controlled motor and 2 heating stages for added comfort and Maximum Energy Savings.The KFUH series commercial unit heater is an efficient,dependable unit heater perfectly suited for high ceiling applications such as warehouses,parking garages and docks.Offering 2-stage energy-saving heat output(-2S Models Only)when paired with a 2-stage 24V thermostat(purchased separately).The 5-speed,ECM motor and blower quietly delivers large volumes of air ranging from 832 to 4308 CFM minimum. With welded mounting channels on the unit,the heater may be mounted at any angle.Safety screens are provided at both the air intake and discharge aperature. The intake filter is replaceable.Thermostat may be ordered separately. FIELD WIRING.Terminal blocks are supplied for field wiring on all units.Consult the National Electric Code for proper wire size and service circuit breaker protection.CONTROL WIRING.Connect low voltage thermostat to terminals R and W on the low voltage terminal block.For fan only operation connect terminals R and G with a switch or thermostat fan switch.Unit shown with standard diffuser model#KFUH DIFFUSER ordered separately. Unit shown with standard diffuser model#KFUH DIFFUSER ordered separately. Additional diffusers are located on the 3rd page of this specification sheet. TWO STAGE COMFORT Why2 Stage is Better 2 Stage controlled Furnaces allow you to use less energy during mild Spring and Fall temperatures. It's like having a smaller furnace installed just for spring and fall,then when winter hits you have the reserve power of the second heating stage to fight off the cold weather. It also has the benefit of creating more even comfort temperatures. *Note: 2-stage heat output(-2S Models Only)when paired with a 2-stage 24V thermostat(purchased separately). The Fumace will run a percentage longer to reach the room temperature so the ECM motors efficiency is key to getting the most out of your Furnace. Two Stage Comfort 120e Yearly Savings 75 100% 00% 15%Typical 33%Max.Savings 70 60% 40% 20 65 0% Standard Furnace Two Stage ■Standard Furnace ■ Two Stage The KFUH ECO2S is more efficient and will save you up to 33% more per year versus standard furnace motors EnERGIGUIDE • Designed for extended life •Cooler operating temperature This Model keklescy 100.0 AFUE • Energy efficient •5 speeds • _ • Improved reliability as 15%2 Stage --- Least Most Efficient Efficient —= --- 100.0 100,0 1 1 1 1. • I � 1 � •i �i 1 1 �• • I�I� I• • i 1 1 cking High Air Velocity Unit Heater KFUH ECO2S Series Ordering Information- single phase "Eq THERMOSTAT TEMP. EFFECTIVE kilo BTUH CONTROL MOTOR RISE AIR WT. MODEL WATTS (000) PHASE VOLTS AMPS STAGE 1 STAGE 2 ELEMENTS VOLTAGE HP CFM RANGE THROW SIZE (lbs.) KFUH2004-1-ECM 3.8 12.8 1 208 18.3 4kW **N/A 1 24 1/3 708-1536 8-18 75ft. Fig.A 57 KFUH2005-1-ECM 5 17.1 1 208 24 5kW **N/A 1 24 1/3 708-1536 10-22 75ft. Fig.A 57 KFUH2008-1-2S1-ECM 8 27.3 1 208 38.5 4.25kW 3.75kW 2 24 1/3 708-1536 16-36 75ft. Fig.A 57 KFUH2010-1-2S1-ECM 10 34.1 1 208 48.1 5kW 5kW 2 24 1/3 708-1536 21-45 75ft. Fig.A 65 KFUH2012-1-2S1-ECM 12 41 1 208 57.7 7.5kW 4.5kW 3 24 1/3 708-1536 25-54 75ft. Fig.A 74 KFUH2015-1-2S1-ECM 15 51.2 1 208 72.1 10kW 5kW 3 24 1/3 708-1536 31-67 75ft. Fig.A 74 KFUH2018-1-2S1-ECM 17.3 58.9 1 208 83.2 8.65kW 8.65kW 4 24 1/3 708-1536 35-77 75ft, Fig.B 74 KFUH2020-1-2S1-ECM 20 68.3 1 208 96.2 10kW 10kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH2025-1-2S1-ECM 25 85.3 1 208 120.2 15kW 10kW 5 24 1/2 1258-1771 45-63 90ft. Fig.B 81 KFUH2030-1-2S1-ECM 30 102.4 1 208 144.2 20kW 10kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH2404-1-ECM 4 13.7 1 240/208* 16.7/14.4* 4kW **NA 1 24 1/3 708-1536 8-18 75ft. Fig.A 57 KFUH2405-1-ECM 5 17.1 1 240/208* 20.8/18* 5kW **N/A 1 24 1/3 708-1536 10-22 75ft. Fig.A 57 KFUH2408-1-2S1-ECM 8 27.3 1 240/208* 33.3/28.8* 4kW 4kW 2 24 1/3 708-1536 16-36 75ft. Fig.A 57 KFUH2410-1-2S1-ECM 10 34.1 1 240/208* 41.7/36.1* 5kW 5kW 2 24 1/3 708-1536 21-45 75ft. Fig.A 65 KFUH2412-1-2S1-ECM 12 41 1 240/208* 50/43.3* 5.75kW 5.75kW 2 24 1/3 708-1536 25-54 75ft. Fig.A 74 KFUH2415-1-2S1-ECM 15 51.2 1 240/208* 62.5/54.1* 10kW 5kW 3 24 1/3 708-1536 31-67 75ft. Fig.A 74 KFUH2418-1-2S1-ECM 17.3 58.9 1 240/208* 72.1 /62.4* 11.5kW 5.75kW 3 24 1/3 708-1536 35-77 75ft. Fig.A 74 KFUH2420-1-2S1-ECM 20 68.3 1 240/208* 83.3/72.1* 10kW 10kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH2425-1-2S1-ECM 25 85.3 1 240/208* 104.2/90.1* 15kW 10kW 5 24 1/2 1258-1771 45-63 90ft. Fig.B 81 KFUH2430-1-2S1-ECM 30 102.4 1 240/208* 125/108.2* 20kW 10kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH2435-1-2S1-ECM 34.5 117.7 1 240/208*143.8/124.4* 23kW 11.5kW 6 24 3/4 1592-2142 52-69 110ft. Fig.B 85 KFUH4804-1-ECM 4 13.7 1 480 8.3 4kW **N/A 1 24 1/3 708-1536 8-18 75ft. Fig.A 57 KFUH4805-1-ECM 5 17.1 1 480 10.4 5kW **N/A 1 24 1/3 708-1536 10-22 75ft. Fig.A 57 KFUH4808-1-2S1-ECM 8 27.3 1 480 16.7 4kW 4kW 2 24 1/3 708-1536 16-36 75ft. Fig.A 57 KFUH4810-1-2S1-ECM 10 34.1 1 480 20.8 5kW 5kW 2 24 1/3 708-1536 21-45 75ft. Fig.A 65 KFUH4812-1-2S1-ECM 12 41 1 480 25 8kW 4kW 3 24 1/3 708-1536 25-54 75ft, Fig.A 74 KFUH4815-1-2S1-ECM 15 51.2 1 480 31.3 10kW 5kW 3 24 1/3 708-1536 31-67 75ft. Fig.A 74 KFUH4818-1-2S1-ECM 17.3 58.9 1 480 36 11.5kW 5.75kW 3 24 1/3 708-1536 35-77 75ft. Fig.A 74 KFUH4820-1-2S1-ECM 20 68.3 1 480 41.7 15kW 5kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH4825-1-2S1-ECM 25 85.3 1 480 52.1 15kW 10kW 5 24 1/2 1258-1771 45-63 90ft. Fig.B 81 KFUH4830-1-2S1-ECM 30 102.4 1 480 62.5 20kW 10kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH4835-1-2S1-ECM 34.5 117.8 1 480 71.9 23kW 11.5kW 6 24 3/4 1592-2142 52-69 110ft. Fig.B 85 *Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V. **Not Available in 2-Stage. Ordering Information- three phase THERMOSTAT TEMP. EFFECTIVE kilo BTUH CONTROL MOTOR RISE AIR WT. MODEL WATTS (000) PHASE VOLTS AMPS STAGE 1 STAGE 2 ELEMENTS VOLTAGE HP CFM RANGE THROW SIZE (lbs.) KFUH2005-3-ECM 5 17.1 1 3 208 13.9 5kW **N/A 1 24 1/3 708-1536 8-18 75ft. Fig.A 57 KFUH2008-3-2S3-ECM 8 27.3 3 208 20.8 4kW 4kW 2 24 1/3 708-1536 8-18 75ft. Fig.A 57 KFUH2010-3-2S3-ECM 10 34.1 3 208 27.7 5kW 5kW 2 24 1/3 708-1536 8-18 75ft. Fig.A 65 KFUH2012-3-2S3-ECM 12.4 42.3 3 208 34.4 7.5kW 3.75kW 3 24 1/3 708-1536 8-18 75ft. Fig.A 74 KFUH2015-3-2S3-ECM 15 51.2 3 208 41.6 10kW 5kW 3 24 1/3 708-1536 8-18 75ft. Fig.A 74 KFUH2020-3-2S3-ECM 20 68.3 3 208 55.5 15kW 5kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH2025-3-2S3-ECM 25 85.3 3 208 69.4 15kW 10kW 5 24 1/2 1258-1771 36-50 90ft. Fig.B 81 KFUH2030-3-2S3-ECM 30 102.4 3 208 83.3 20kW 10kW 6 24 3/4 1592-2141 44-60 110ft. Fig.B 85 KFUH2040-3-2S3-ECM 40 136.5 3 208 111 20kW 20kW 8 24 2 x1/2 2516-3542 36-50 90ft. Fig.C 152 KFUH2050-3-2S3-ECM 50 170.7 3 208 138.8 25kW 25kW 10 24 2 x1/2 2516-3542 36-50 90ft. Fig.C 162 KFUH2060-3-2S3-ECM 60 204.8 3 208 166.5 30kW 30kW 12 24 2 x3/4 2516-3542 1 44-60 110ft. Fig,C 1 170 KFUH2405-3-ECM 5 17.1 3 240/208* 12/10.4* 5kW **N/A 1 24 1/3 1258-1771 36-50 90ft. Fig.A 57 KFUH2410-3-2S3-ECM 10 34.1 3 240/208* 24/20.8* 5kW 5kW 2 24 1/3 1258-1771 36-50 90ft. Fig.A 65 KFUH2412-3-2S3-ECM 12 41 3 240/208* 28.9/25* 6kW 6kW 3 24 1/3 1258-1771 36-50 90ft. Fig.A 74 *Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V. **Not Available in 2-Stage. ManufacturingKing Electrical Company 9131Oth Avenue South,Seattle,WA 98108 phone 206.762.0400 fax 206.763.7738 chiking High Air Velocity Unit Heater KFUH ECO2S Series Ordering Informati,..- three phase THERMOSTAT TEMP. EFFECTIVE kilo BTUH CONTROL MOTOR RISE AIR WT. MODEL WATTS (000) PHASE VOLTS AMPS STAGE 1 STAGE 2 ELEMENTS VOLTAGE HP CFM RANGE THROW SIZE (lbs.) KFUH2415-3-2S3-ECM 15 51.2 3 240/208` 36.1 /31.2- 10kW 5kW 3 24 1/3 1258-1771 1 36-50 90ft. Fig.A 74 KFUH2418-3-ECM 17.3 58.9 3 240/208' 41.6/36 17.25kW "N/A 3 24 1/3 1258-1771 36-50 90ft. Fig.A 74 KFUH2420-3-2S3-ECM 20 68.3 3 240/208" 48.1 /41.6* 10kW 10kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH2425-3-2S3-ECM 25 85.3 3 240/208' 60.1 /52" 15kW 10kW 5 24 1/2 1258-1771 36-50 90ft. Fig.B 81 KFUH2430-3-2S3-ECM 30 102.4 3 240/208' 72.2/62.5" 20kW 10kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH2435-3-2S3-ECM 34.5 117.8 3 240/208' 83/71.8* 17.25kW 17.25kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH2440-3-2S3-ECM 40 136.5 3 240/208" 96.2/83.3" 20kW 20kW 8 24 2 x 1/2 2516-3542 36-50 90ft. Fig.C 152 KFUH2450-3-2S3-ECM 50 170.7 3 240/208* 102.3/104* 25kW 25kW 10 24 2 x 1/2 2516-3542 36-50 90ft. Fig.C 162 KFUH2460-3-2S3-ECM 60 204.8 3 240/208'144.3/124.9` 30kW 30kW 12 24 2 x 3/4 3184-4284 44-60 110ft. Fig.C 170 KFUH2470-3-ECM 70 239 3 240/208*168.4/145.7* 70kW *'N/A 12 24 2 x 3/4 3184-4284 44-60 110ft. Fig.C 170 KFUH4805-3-ECM 5 17.1 3 480 7.2 5kW "N/A 1 24 1/3 1258-1771 36-50 90ft. Fig.A 57 KFUH4810-3-2S3-ECM 10 34.1 3 480 12.0 5kW 5kW 2 24 1/3 1258-1771 36-50 90ft. Fig.A 65 KFUH4812-3-ECM 12 41 3 480 14.4 12kW "N/A 3 24 1/3 1258-1771 36-50 90ft. Fig.A 74 KFUH4815-3-2S3-ECM 14.4 51.2 3 480 17.3 10kW 5kW 3 24 1/3 1258-1771 36-50 90ft. Fig.A 74 KFUH4818-3-ECM 18 58.9 3 480 21.7 17.3kW **N/A 3 24 1/3 1258-1771 36-50 90ft. Fig.A 74 KFUH4820-3-2S3-ECM 20 68.3 3 480 24.1 10kW 10kW 4 24 1/2 1258-1771 36-50 90ft. Fig.B 76 KFUH4825-3-2S3-ECM 25 85.3 3 480 30.1 15kW 10kW 5 24 1/2 1258-1771 36-50 90ft. Fig.B 81 KFUH4830-3-2S3-ECM 30 102.4 3 480 36.1 20kW 10kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH4835-3-2S3-ECM 34.5 117.8 3 480 41.5 17.25kW 17.25kW 6 24 3/4 1592-2142 44-60 110ft. Fig.B 85 KFUH4840-3-2S3-ECM 40 136.5 3 480 48.1 20kW 20kW 8 24 2 x 1/2 2516-3542 36-50 90ft. Fig.C 152 KFUH4850-3-2S3-ECM 50 170.7 3 480 60.1 25kW 25kW 10 24 2 x 1/2 2516-3542 36-50 90ft. Fig.C 162 KFUH4860-3-2S3-ECM 60 204.8 1 3 480 72.2 30kW 30kW 12 24 2 x 3/4 3184-4284 44-601 110ft. Fig.C 17 KFUH4870-3-ECM 70 239 1 3 480 84.2 70kW ""N/A 12 24 2 x 3/4 3184-4284 44-601 110ft. Fig,C 170 'Dual rated heaters will draw 13%less amps and 25%less wattage when operated at 208V. **Not Available in 2-Stage. Cnn+nw Ir•n"1Qd Options ADD SUFFIX DESCRIPTION WEIGHT(lbs.) -T Factory Installed 1-Stage Stat(SPST).Temperature range 40F to 100F(For 1-Stage Models Only) N/A -2TS Factory Installed 2-Stage Stat(DPST).Temperature range 40F to 100F(For 2-Stage:-251&-2S3 Models Only) N/A -SF Factory Installed Summer Fan Switch N/A -DS32 Factory Installed 32 Amp,3-Pole Non-Fused Locking Disconnect Switch N/A -DS63 Factory Installed 63 Amp,3-Pole Non-Fused Locking Disconnect Switch NA -DS80 Factory Installed 80 Amp,3-Pole Non-Fused Locking Disconnect Switch N/A -DS100 Factory Installed 100 Amp,3-Pole Non-Fused Locking Disconnect Switch N/A -3/4 Sub 3/4 HP Motor for 20kW&25kW Models Only N/A Accessories MODEL UPC DESCRIPTION WEIGHT(lbs.) KFUH-DIFFUSER 15741 Standard KFUH Air Diffuser 5.0 KFUH-RD 15743 Radial Diffuser for Wide Pattern Heat Dispersion 4.0 KFUH-90D 15728 Right Angle Elbow(90°)Diffuser with Adjustable Louvers 15.0 KFUH-90RD 15729 Right Angle Elbow(90°)with Radial Diffuser 14.0 1 F85U-22PR 19054 2-Stage,24V 7 Day Programmable Thermostat 44F-95F(For use with 2-stage heaters) 1.0 1F85U-22NP 19044 2-Stage,24V Non-Programmable Thermostat 44F-95F(For use with 2-stage heaters) 1.0 1E30N-91O 55379 1-Stage,24V Thermostat Mercury Free-Vertical 45F-90F(For use with 1-stage heaters) 1.0 Manufacturingl" r r King Electrical Company 9131Oth Avenue South, 98108 phone 206.762.0400 fax 206.763.7738 cking High Air Velocity Unit Heater KFUH ECO2S Series I � W-W Air Flow Chat Air Flow Chart Air Flow Chart (For 4 to 17.3kW Units with 1/3HP ECM Motor) (For 20 to 50kW Units with 1/2HP ECM Motor) (For 20 to 70kW Units with 3/4HP ECM Motor) MODEL KW TORQUE CFM RISE MODEL KW TORQUE CFM RISE MODEL KW TORQUE CFM RISE (F) (F) (F) (1)15.5 1,258 50 (1)26.0 1,592 1 40 KFUH**04 4 9.4 919 14 KFUH**20 20 KFUH**20 20 30.0 1,789 35 12.0 1,085 12 22.5 1,575 40 (Optional) mm 17.0 1,320 10 26.0 1,690 37 3/4 HP 40.5 2,080 30 20.0 1,536 8 30.0 1,771 36 45.0 2,142 30 15.5 1,258 63 (1)26.0 1,592 50 9.4 919 17 19.0 1,466 54 30.0 1,789 44 KFUH**05 5 12.0 1,085 15 KFUH**25 25 (1)22.5 (Optional) 1,575 50 KFUH 25 17.0 1,320 12 3/4 HP 40.5 2,080 38 20.0 1,536 10 30.0 1,771 45 45.0 2,142 37 (1)6.8 708 36 (1)15.5 2,516 50 (1)26.0 1,592 60 KFUH-40 40 30.0 1,789 53 KFUH**08 8 12.0 1,085 23 22.5 3,150 40 KFUH**30 30 35.0 1,814 52 17.0 1,320 19 26.0 3,380 37 20.0 1,536 16 30.0 3,542 36 45.0 2,142 44 (1)6.8 708 45 15.5 2,516 63 26.0 1,592 69 19.0 2,932 54 (1)30.0 1,789 62 KFUH**10 10 12.0 1,085 29 KFUH**50 50 (1)22.5 3,150 50 KFUH**35 35 35.0 1,814 61 17.0 1,320 24 20.0 1,536 21 30.0 3,542 45 45.0 2,1421 52 6.8 708 54 (1)26.0 3,184 60 30.0 3,578 53 KFUH**12 12 (2)12.0 1,085 35 KFUH**60 60 35.0 3,628 52 17.0 1,320 29 20.0 1,536 25 45.0 4,284 44 6.8 708 67 26.0 3,184 69 (1)9.4 919 52 (1)30.0 3,578 62 KFUH**15 15 ** 35.0 3628 61 KFUH 70 70 17.0 1320 36 20.0 1536 31 45.0 4,284 52 6.8 708 77 1 9.4 919 59 KFUH**18 17.3 12.0 1,085 50 i i • 20.0 11,536 35 (A)**Represents the voltage,20=208V,24=24OV,48=48OV. (D)(1)=Stage 1 Torque Settings (2)=Stage 2 Torque Settings Voltage of the KF/KFS unit does not affect the data in this table. /(2)=Default for Single Stage KFUH (B)NR=Not Recommended,Temperature Rise is above maximum design parameter. (E)Blower:10"diameter,8"wide (C)The highlighted cells are the factory default torque setting for each model. The ECM motor has 5 field adjustable torque settings,allowing for a wide range of design choices. Engineering Specification Contractor shall supply and install KFUH ECO2S Series unit heaters manufactured by King Electrical Mfg.Company. Heaters shall be of the wattage and voltage as indicated on the plans. Transformer:Each unit is equipped with a heavy duty low voltage(24 Volt) This low noise,5 speed motor is designed for use with air conditioning transformer for the thermostat control circuit. capability as well as heating.Very quiet operating.60 second fan delay. 2-Stage Heating:2-stage energy-saving heat output(-2S Models Only)when Overcurrent Protection:208&240 volt KFUH ECO2S models have 60 amp paired with a 2-stage 24V thermostat(purchased separately), circuit breakers with single strike terminal block.Units over 48 amps have 60 Heating Elements:Quick heating,long life Ni-Chrome elements are sized to amp fusing. provide proper watt density for maximum heat dissipation by fan-forced air Limit Control:Integral automatic high temperature limit control in each convection currents. heating element bank prevents the delivery of air at unsafe temperatures. Terminal Block:For single strike field wiring. 20-35 kW use a manual reset limit control to completely shut the unit heater Low Voltage Terminal Block:For 24 Volt control, off should overtemperature occur. Air Filter:Convenient access for replacement of standard 16"x 20"x 1"filter. Fan Relay:Heavy duty fan relay standard with summer fan operation. Motor:Energy Saving,Long life,thermally protected,permanently lubricated, Approvals:cULus Certified for US&Canada direct drive ECM motor-no belts to adjust or slip. • 1 �. ' 1 0 I ': 1. 0 1 1• • I�11 1. cking High Air Velocity Unit Heater KFUH ECO2S Series Dimensional Data FIGURE A I I FIGURE B - 30Yz" I 'N--►I 37Yz" 26" 1/2" 13" 16" Mounting 16" Mounting Holes Holes 11/2 1�5„y 5„ P/z" 5" 5"�I 20" 20" 16"x 20"x 1" 16"x 20"x 1" Filter Filter Double Case Mounting FIGURE C 16 37.5" Horizontal Flow 16" Ceiling Mounted Top of Unit 7 Tap of Unit o 0 20" Knockout Access Panels Located on �� Power Knockouts Vertical Flow Bottom of Units Wall or Post Mounted Diffusers KFUH-90RD KFUH-90D Aidl d. 1 1W&M ': 1: I 1 I• • 1�11 1• . • 1 OW 1 Ever �een CONTROLS Refrigeration &HVAC DESIGN INSTALLATION SERVICE Electric Wall Heaters (EWH) 727 SOUTH KENYON ST.-SEATTLE, WA. 98108 (206) 763-1744 -FAX(206) 763-2389 cking Wall HeaterpAw series Pic-A-Watt Model Code: A:Wall Heater - B:12-120V 24-240V 20- 2 -2 ) C:Wattss(25(250 too 225050) D:Interior&Grill - E:Right Hand Feed VP Pivkwatt r c&us S � ,`•yam LISTED aaorecnoH Pic-A-Watt'Element •Whisper Quiet �R •Standard color:white Squirrel Cage Blower ■ Multiple wattages 250-2250 (optional almond color available) C-Frame Motor 20 gauge powder-coated grill • 120,208,240,or 277 Volts )4W Patented Smart Limit Protection' Wall can with QuickSetT°'stud alignment tabs •5 Year Warranty i ne rH w benes The Original Multi-Watt steel fin heater and our most popular heater for single family residences and upscale condominiums. King's exclusive Pic-A-Watt steel fin element allows customers to select from a range of wattage options,tailoring the heater to an area's specific heating requirements. Perfect for large living areas yet whisper quiet enough for bedrooms.The premium combination of an efficient high-mass steel element and whisper quiet squirrel cage blower, offers top of the class performance and years of trouble -free operation. PAW comes with five year warranty and 20+year history of reliability. For best results use with an electronic line voltage wall thermostat.Also available with a built-in thermostat.The wall can shall be 20 gauge electro-galvanized steel and contain knockouts through which power leads are brought.The wall can shall be able to mount directly to wall studs in new or existing construc- tion.The wall can shall be provided with QuickSetTM stud alignment tabs, used for maintaining proper depth during new installation.The wall can shall be supplied with a factory installed ground wire. Clearance:6"to a side all, 4"from floor minimum. Ordering Information MODEL UPC VOLTS WATTS AMPS SHIP WEIGHT Ibs PAW2022 00512 208 500.750.1000.1250.1500.1750.2250 2.4-10.8 9.5 PAW2422 16300 240 500.750.1000.1250.1500.1750.2250 2.1-9.4 9.5 PAW2720 16302 277 1000.2000 3.6-7.2 9.5 Engineering Specifications Contractor shall supply and install PAW Series in-wall forced-air electric heaters manufactured by King Electrical Mfg. Company, of the wattage and voltage as indicated on the plans. and motor in the event normal operating temperatures are exceeded. Ratings:Heaters shall be available in wattages of 250 to 2,250 If thermal overload trips due to abnormal operating temperatures,thermal at 120,208,240,or 277 Volts. overload shall remain open until manually reset by turning the heater off Blower and Motor:A whisper quiet tangential blower,delivering 75 for 15 minutes.Automatic reset of thermal overloads,which allow the CFM,shall be driven by a shaded pole,permanently lubricated,C-frame element to continue to cycle under abnormal conditions,will not be type motor with impedance protection and sealed bearings.Motors shall accepted. be the same voltage as the heater. Grill:The grill shall be a louvered,one-piece design with rounded edges Elements:Element assemblies shall consist of three steel sheathed on all four sides,with rounded corners to prevent snags from contact with heating tubes in a furnace-brazed,plate-finned,block design.Each other materials.The grill shall be epoxy powder-coated in white or sheathed tube shall contain coiled Ni-Chrome wire embedded in an almond. insulator of Magnesium Oxide.The element assembly shall provide up to Wall Can:The wall can shall be 20 gauge electro-galvanized steel and seven(7)possible wattage configurations available for selection during shall contain a minimum of three(3)knockouts.The wall can shall have field installation.The use of external resistors,diodes,or other weak links a depth gauge indicator,and a factory installed,insulated and stranded to obtain multiple wattages will not be acceptable. copper ground-wire.Minimum 4"clearance to floors and 6"sidewalls. Thermal Overload:Heaters shall be equipped with King's patented Zero clearance to combustibles in the wall. thermal overload Smart Limit Protection®,which disconnects elements Approvals:cULus(E41422) ManufacturingKing Electrical Company 9131Oth Avenue South, `98108 phone 206.762.0400 fax 206.763.7738 1 chiking Wall HeaterpAw series Pic-A-Watt Dimensional Data BOTTOM =knockout location } LEFT 4" FRONT SIDE I GRILL 1„ f 1 ,2-,� 1 1-3/4" TOP 7-,/2" nP f + �4" � 13-1/2" Options ADD SUFFIX DESCRIPTION WEIGHT Ibs -A Almond Color 9.5 -1 Interior and Grill Only(no wall can) 7.5 -H Interior Only(no can or grill) 7.5 -U ULTRA GRILL Custom Bar Grill(not available with built-in thermostat) 12.0 -RF Right Hand Feed 9.7 -SS Stainless Steel Grill 9.6 -OGA 13"H x 13.5"W Retrofit Grill 10.0 -OGB 8.5"H x 17"W Retrofit Grill 10.0 Accessories MODEL UPC DESCRIPTION WEIGHT Ibs PAWIC 00515 Recess Wall Can 2.5 PAWF 16319 Recess Can with Flange(remodel) 2.0 PAWS 16305 PIC-A-WATT®Surface Can-White 5.5 13.5"L x4.5"Wx7.5"H PAWS-A 19298 PIC-A-WATTO Surface Can-Almond 5.5 13.5"L x 4.5"W x 7.5"H PAWG 16304 Grill-White 1.0 PAWG-ALMOND 16335 Grill-Almond 1.0 PAWG-SS 16330 Grill-Stainless Steel 1.0 PAWOG-A 00555 13"H x 13.5"W x.5"D Retrofit Grill 3.0 PAWOG-B 00560 8.5"H x 17"W x.5"D Retrofit Grill 3.0 ULTRA-W 18740 Ultra Grill-White 4.0 ULTRA-A 18745 Ultra Grill-Almond 4.0 TKIT-1 BW 20654 Built-in Single Pole Single Throw Thermostat Kit,Bright White 0.5 TKIT-2BW 20655 Built-in Double Pole Single Throw Thermostat Kit,Bright White 0.5 TKIT-1 11058 Built-in Single Pole Single Throw Thermostat Kit,Almond 0.5 TKIT-2 11059 Built-in Double Pole Single Throw Thermostat Kit,Almond 0.5 MINIMUM CLEARANCE Zero clearance to insulation 4" above floor 6"from adjacent wall PAW ULTRA Upgrade any PAW series heater with the ultra grill. Its sleek and modern design compliments 0 more luxurious spaces. .i Kin •Electrical Manufacturing Company 91311Oth Avenue South, 98108 phone 206.762.0400 fax 206.763.7738 www.king-electric.com cking Wall HeaterpAw series PIC-A-Waft Options &Accessories Exploded view PAWS Surface Wall Enclosure 13.5"L x4.5"Wx7.5"H PAWOG-B Oversize Grill PAWG-SS Stainless Steel PAWOG-A Oversize Grill ZOES�� .� 8.5"Hx17"W 7.125"H x 13.625"W 13"Hx13.5"W ULTRA Grill TKIT Thermostat For Wall Heaters h � 7.25"H x 15.875"W King Electrical Manufacturing Company9131Oth Avenue South,Seattle,WA 98108 phone 206.762.0400 fax 206.763.7738 1 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Project: Northsound Logistics-2021 WSEC 51 st Ave NE Arlington,WA 98223 Date: 2025-04-30 Applies Code Section Code Provision Compliance Information Required In Permit Location in Building Department Documentation Documents Notes SCOPE C103.6.3 Construction For a shell&core or tenant space(first build- 7- documents-General out)project,indicate if there is no mechanical scope included in the project. C103.1 Construction For an alteration project,indicate if there is documents-General no mechanical scope included in the project. PERFORMANCE CRITERIA&SYSTEM DESIGN NA C403.1 Exempt process Identify equipment used by manufacturing, equipment industrial or commercial processes that are not for space conditioning or maintaining comfort and amenities for occupants;identify provisions applicable to this equipment per C403.1 exception C403.1.1 HVAC total system For systems serving office(including medical performance ratio office),retail,library,or education (TSPR) occupancies,or serving R-2 dwelling units or common areas,provide a TSPR report that demonstrates the proposed design ratio is equal to or greater than the standard reference design ratio,or exception applied NA C403.1.2 Calculation of heating Provide load calculations in accordance with and cooling loads ASHRAE Std 183 or equivalent,using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery NA C403.1.3 Data centers Provide documentation that demonstrates that data center systems comply with the maximum allowed Design MLC and Annualized MLC per ASHRAE 90.4-2019. NA C403.2.1 Zone isolation If there are HVAC zones that are intended to C403.4.2.2 be occupied non-simultaneously,identify isolation zone areas on plans;if multiple zones intended to be occupied simultaneously will be combined into a single isolation zone, include on plans that the combined zone area does not exceed 25,000 sf and does not include more than one floor;or exception applied NA C403.2.1 Zone isolation Indicate locations of associated zone isolation C403.4.2.2 dampers in HVAC and DOAS distribution systems and exhaust systems NA C403.2.1 Zone isolation Refer to HVAC Controls section in C403.4.2.2 Requirements List for applicable automatic setback and shutdown controls requirements EQUIPMENT SELECTION&PERFORMANCE Page 1132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C403.3.2.6 Electric heating/ Verify all packaged and split electric M001 cooling equipment equipment with>6,000 Btu/h cooling capacity and any amount of heating is a heat pump with reverse-cycle defrost and operates in heat pump mode when outdoor air temperature is>25 degree F;include in equipment schedules NA C403.3.2.6 Electric heating/ Verify electric heat in the main supply duct cooling equipment before VAV boxes served by cooling only systems>6,000 Btu/h is a heat pump with reverse-cycle defrost and operates in heat pump mode when outdoor air temperature is >25 degree F;include in equipment schedules. NA C401.3 HVAC Heating Fuel For all heating equipment,identify whether it C403.1.4 qualifies for the C403.1.4 general prescriptive path,a C403.1.4 exception,or for the C401.3 Fossil Fuel Heating path;for equipment qualifying for the C403.1.4 general prescriptive path by exception,document the exception and provide supporting information NA C401.3 HVAC Heating Fuel For projects with equipment utilizing the C403.1.4 C401.3 Fossil Fuel Heating path,provide an C406.1 accounting of the total heating capacity and the C401.3 equipment heating capacity for each distinct area utilized in the C406 calculation. NA C403.1.4 HVAC Heating Fuel, To qualify for exception 2,provide a list of exception 2 Dwelling each separate space in the dwelling or sleeping and sleeping units unit,indicate the number of exterior walls the space has,the presence of fenestration,and the allowed watts;document the heat provided in each space is below the allowed capacity in the space NA C403.1.4 HVAC Heating Fuel, To qualify for exception 5,provide exception 5 Air-to-air documentation that the heat pump is sized to heat pumps meet the heating load at an outdoor air temperature<_32°F and has a ratio of heating capacity at 47°F to supplemental resistance heat capacity>_2.0 in zone 4 and>_ 1.0 in zone 5;indicate unit control by either a thermostat designed for heat pump use,a multistage thermostat with an outdoor air temperature thermostat wired to energize supplemental heat only on the last stage or heating and when the outdoor air temperature is<_32°F,or equipment is NAECA rated with integral control Page 2132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.1.4 HVAC Heating Fuel, To qualify for exception 6,provide exception 6 Air-to- documentation that building heating is water heat pumps provided by air-to-water heat pumps with a heating capacity>_75%of the design heating load at 29'F;indicate controls configured to lock out supplemental heat when the outdoor air temperature is>36°F unless the hot water supply set point has not been maintained for 20 minutes;indicate controls configured to use the compressor as the first stage of heating down to the compressor minimum rated temperature except during start up and defrost NA C403.1.4 HVAC Heating Fuel, To qualify for exception 7,provide exception 7 Ground documentation building heating provided by source heat pumps ground source heat pumps;;indicate controls configured to lock out supplemental resistance heat when the source-side entering water temperature is>_42°F unless the hot water supply set point has not been maintained for 20 minutes;indicate controls configured to use the compressor as the first stage of heating;indicate the ground source heat exchanger shall be sized so heat pump annual output is>_70%for the total annual heating output based upon the final year of a 30-year simulation using IGSHPA listed software NA C403.1.4 HVAC Heating Fuel, To qualify for exception 8,document the exception 8 Small capacity or area served for the electric systems resistance and fossil fuel systems and demonstrate that it is<_5%of the building total heating capacity or area NA C401.3.6 Electrification For all equipment following the fossil fuel readiness path,indicate on plans that spare electrical branch circuit and service entrance conduit is installed and sized to support future conversion of fossil fuel heaters to heat pumps;indicate on plans additional room in the electric room and transformer rooms and vaults be provided and sized to accommodate future service upgrades for conversion of all fossil fuel equipment to heat pumps. NA C403.3.1 Equipment and Indicate that output capacities of heating and system sizing cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads;note exceptions applied YES C403.3.2 HVAC equipment Provide equipment schedules on plans and in M001 C403.9.1 performance WSEC mechanical equipment compliance requirements reports;indicate equipment type,calculated (efficiency) loads,capacity,rated and WSEC minimum efficiencies for all heating and cooling equipment;include supply and ventilation air cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency(manufacturer rated) Page 3132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C405.8 Electric motor List all motors> 1/12 hp(that are not integral efficiency to a rated piece of equipment)in the mechanical or electrical equipment schedules on plans;indicate motor type and applicable efficiency table,hp,rpm,number of poles and rated efficiency,or exception applied NA C403.3.2.1 Gas and oil-fired For gas and oil fired forced air furnaces with forced air furnace capacity>225,000 Btu/h and all unit heaters, and unit heaters indicate in equipment schedule intermittent ignition or IID,flue or draft damper,and rated jacket loss NA C403.3.3 Hot gas bypass For cooling equipment with hot gas bypass, limitation for DX provide either multiple step unloading or cooling equipment continuous capacity modulation;indicate bypass capacity per Table C403.3.3 NA C403.3.2.7 Humidification For cooling systems with humidification equipment that are also required to have air economizer,indicate humidifier is adiabatic (direct evaporative or fog atomization),or exception applied C403.3.2 Hydronic equipment Refer to Requirements List section Hydronic Systems-Equipment Selection& Performance for selection criteria specific to chillers and boilers NA C403.9 Heat rejection Refer to Requirements List section Heat equipment Rejection Systems-Equipment Selection& Performance for selection criteria specific to cooling towers,dry coolers and condensers (air-cooled and evaporative) NA C403.13 Dehumidification in Indicate dehumidification equipment serving spaces for plant plant growth spaces and which C403.13 growth compliance option is met EQUIPMENT SELECTION&PERFORMANCE-DEDICATED OUTSIDE AIR SYSTEMS(DOAS) NA C403.3.5.5 DOAS supplemental If DOAS has heating capability,indicate C403.7.3 heating and cooling hearing controlled to limit supply air to<_ 55°F.If heating is used for defrost control, indicate heat is to be locked out when outdoor air temperature is<_35'F,modulates to 10% of peak capacity.Provide sizing calculations that show heating capacity sized at design temperatures to prevent damage to unit and heat supply air<_55°F. NA C403.3.5.5 DOAS supplemental If DOAS has cooling capability,indicate heating and cooling cooling coil is used only for dehumidification only,is sized to meet the peak dehumidification requirement at design conditions,and is controlled to maintain supply air or zone relative humidity. Page 4132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com YES C403.3.5 Dedicated outdoor air For buildings with occupancies required to M203 C403.3.5.4 systems comply with the DOAS provisions per Table C403.3.5,identify on plans all occupancies in the building and indicate which occupied spaces are required to have ventilation air delivered by a DOAS;or exception applied NA C403.3.5 Dedicated outdoor air If natural ventilation exception is applied, C403.3.5.4 systems identify these spaces on plans;indicate operable window area complies with IMC Section 402;provide documentation describing how required ventilation will be provided during all occupied hours,including during inclement weather NA C403.3.5 Dedicated outdoor air If high efficiency VAV exception is applied, C403.3.5.4 systems identify these spaces on plans;refer to Single Zone VAV section for Groups A-1,A-2 and A-3 occupancy classifications,or Multiple Zone VAV for other than Groups A-1,A-2 and A-3(per Table C403.3.5) NA C403.3.5 Dedicated outdoor air If compliance with the DOAS provisions is C403.3.5.6 systems deemed to be impractical,provide documentation that demonstrates the alternate design strategy applied that achieves a comparable level of energy efficiency,as pre- approved by the AHJ NA C403.3.5 Dedicated outdoor air Refer to Requirements List section after systems Multiple-Zone Air Systems for High Efficiency Multiple-Zone VAV Systems exception to C403.3.5 DOAS NA C403.3.5 Dedicated outdoor air Refer to Requirements List section after High systems Efficiency Multiple-Zone Air Systems for High Efficiency Single-Zone VAV Systems exception to C403.3.5 DOAS YES C403.3.5.1 DOAS energy For all DOAS systems,indicate exhaust air M001 recovery method and ER method and basis of rated effectiveness effectiveness (sensible or latent);indicate>_68%sensible or >_60%enthalpy recovery ratio at design conditions;or exception applied NA C403.3.5.2 DOAS fan power For DOAS with no fans or fan arrays with input power>_ 1kW,indicate total system fan power does not exceed 1 watt per cfm NA C403.3.5.2 DOAS fan power For DOAS with any fans or fan arrays with input power>_ 1kW,indicate total system fan power complies with fan power limitation per Section C403.8.1 NA C403.3.5.3 Heating/cooling Indicate systems and equipment associated system fan controls with the delivery of zone level heating and with DOAS cooling(fans,hydronic pumps,primary air dampers,etc.)are configured to shut off,and central equipment is configured to turn down, when there is no call for heating or cooling in the zone they serve Page 5132 Mechanical Requirements • • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.3.5.3 Heating/cooling If applying Exception to heating/cooling fans system fan controls used for air mixing in the space during with DOAS deadband periods,include fan watts per cfm in equipment schedule YES C403.3.5.4 Decoupled DOAS Indicate method of delivery of DOAS supply M203 supply air air to the occupied space(directly into space, downstream of terminal heating/cooling coils);or exception applied NA C403.6.5 Multiple zone DOAS For DOAS serving multiple zones with DDC controls,indicate controls configured to reduce the volume of outdoor air in each zone independently when the zone is unoccupied; or exception applied ADDITIONAL ENERGY EFFICIENCY MEASURE-DEDICATED OUTSIDE AIR SYSTEMS(DOAS) C406.2.2.6 High performance For all building occupancies,to comply with DOAS-Energy this additional efficiency credit,demonstrate recovery compliance withC403.3.5 effectiveness and fan power C406.2.2.6 High performance Indicate energy recovery sensible DOAS-Energy effectiveness of all DOAS is>_80% recovery effectiveness and fan power C406.2.2.6 High performance For each system,indicate that total system fan DOAS-Energy power does not exceed 0.769 watts per cfm or recovery is<_80%of the fan power allowance for a effectiveness and fan constant volume system calculated per power C403.8.1 FANS AND FAN CONTROLS YES C403.8.1.2 Fan power limitation For all HVAC fan systems associated with M001 conditioned space and containing 1 or more fans with electrical input>_1 kW shall provide the total nameplate hp and the fan system electrical input power calculated per C403.8.1.2 in equipment schedules on project plans NA C403.8.1.1 Fan power limitation For all HVAC and DOAS systems associated with conditioned space with 1 or more fans with electrical input power> 1 kW,provide fan system electrical input power calculations per Section C403.8.1.2 to verify it complies with fan power budget per Section C403.8.1.1 NA C403.8.2 Motor nameplate hp For HVAC systems with total fan motor nameplate hp>5hp,indicate fan motors specified are the smallest available motor hp size greater than fan bhp,note exceptions applied Page 6132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C405.8 Fractional hp fan For all fractional hp fan motors(1/12-<1 motors hp),indicate that motors comply with applicable WSEC efficiency tables;if motor type is not listed in an efficiency table, indicate whether fan has an electronically commutated motor,has motor rated efficiency of at least 70%,or exception applied NA C403.8.3 Fan efficiency For individual fans or fan arrays,indicate in equipment schedule that rated FEI for all applicable fans part of a variable-air volume system is>_0.95 and>_ 1.0 in all other systems,or exception applied;indicate these fans are sized at the design point of operation C403.8.4 Low-capacity For all ventilation system fans with motors<_ ventilation fans 1/12 hp,indicate in equipment schedule the fan flow rate and efficacy(cfm/watt),or exception applied;refer to Table C403.8.4 NA C403.2.4 Variable flow For fan motors>_5 hp,indicate method of capacity-fans variable flow control(VSD or equivalent method)in equipment schedule,or exception applied NA C403.8.5.1 Fan airflow control For DX air handling units with cooling capacity>42,000 Btu/h and evaporative and chilled water air handling units with fan>_ 0.25 hp,indicate whether system is single zone or multiple zone and related control method(cooling capacity controlled in response to space temperature,space temperature is controlled by modulating supply airflow,or both) NA C403.8.5.1 Fan airflow control For mechanical cooling systems(includes DX and chilled water coils)that control cooling capacity in response to space temperature- Provide a minimum of two stages of fan control;indicate minimum fan speed is<_ 66%of full speed drawing<_40%of full speed fan power during periods of low cooling or ventilation only NA C403.8.5.1 Fan airflow control For other mechanical cooling systems (includes DX and chilled water coils)that control space temperature by modulating airflow(in lieu of,or in addition to, controlling capacity in response to space temperature)-Provide fan controls for modulating supply airflow;indicate minimum fan speed is<_50%of full speed drawing<_ 30%of full speed fan power during periods of low cooling or ventilation only;or exception applied NA C403.8.6 Large-diameter Where provided,indicate large-diameter ceiling fans ceiling fans to be tested and labeled in accordance with AMCA 230. ADDITIONAL ENERGY EFFICIENCY MEASURE-IMPROVED HVAC TSPR Page 7132 Mechanical Requirements • • i of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C406.2.2.1 Improved HVAC To comply with this additional efficiency TSPR credit,indicate systems are required to provide a TSPR report per C403.1.1; demonstrate that the proposed design ratio is at minimum 5%higher than the standard reference design ratio;for projects prorating the credit the TSPR report must show the proposed design exceeds the claimed increase used for proration ADDITIONAL ENERGY EFFICIENCY MEASURE-MORE EFFICIENT HVAC EQUIPMENT COOLING AND FAN PERFORMANCE C406.2.2.2 More efficient To comply with this additional efficiency cooling and fan credit,provide a list of all cooling equipment performance in the building or credit area and calculations that demonstrate(based on cooling output capacity)that 90%or more of all HVAC cooling equipment serving conditioned floor areas are listed in the tables of Section C403.3.2 NA C406.2.2.2 More efficient In addition to system selection requirement, C406.2.2.2.1 cooling and fan demonstrate that 90%or more of all HVAC performance cooling capacity serving conditioned floor areas in the building or credit area is delivered by equipment at least 5%better than the listed WSEC efficiency,seasonal or annualized where available other wise use full load efficiency C406.2.2.2 More efficient For projects prorating the credit in C406.2.2.2.1 cooling and fan accordance with Equation 4-15 include performance calculations for equipment representing at least 90%of the cooling capacity in the building or credit area that demonstrate the capacity weighted average better than code efficiency;for equipment with multiple requirements the seasonal or annualized efficiency shall be used C406.2.2.2 More efficient In addition to system selection and efficiency C406.2.2.2.3 cooling and fan requirements,if fan energy is not included in performance equipment rating or if it is but the fan has been upsized from rated conditions, demonstrate fan power is<_95%of the allowed fan power in Section C403.8.1. ADDITIONAL ENERGY EFFICIENCY MEASURE-MORE EFFICIENT HVAC EQUIPMENT HEATING PERFORMANCE NA C406.2.2.3 More efficient To comply with this additional efficiency HVAC equipment credit,provide a list of all heating equipment heating performance in the building or credit area and calculations that demonstrate that 90%or more of all HVAC heating capacity serving conditioned floor area is delivered by equipment listed in the tables of Section C403.3.2 Page 8132 Mechanical Requirements • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C406.2.2,3 More efficient In addition to system selection requirement, C406.2.2.3.2 HVAC equipment demonstrate that 90%or more of all HVAC heating performance heating capacity serving the building or credit area is delivered by equipment at least 5% better than the listed WSEC efficiency, seasonal or annualized where available other wise use full load efficiency NA C406.2.2.3 More efficient For projects prorating the credit in C406.2.2.3.2 HVAC equipment accordance per Equation 4-16 include heating performance calculations for equipment representing at least 90%of the heating capacity serving the building or credit area that demonstrate the capacity weighted average better than code efficiency;for equipment with multiple code requirements the seasonal or annualized efficiency shall be used NA C406.2.2.3 More efficient In C402.1.1 low energy and C402.1.1.2 semi- C406.2.2.3.2 HVAC equipment heated spaces demonstrate that 90%of the heating performance heating capacity in the building or area is provided by electric infrared or gas-fired radiant equipment for localized heating applications. VENTILATION,EXHAUST&ENERGY RECOVERY NA C403.7.1.2 Demand control For each required demand control ventilation ventilation design system,indicate outdoor air automatically changes in response to a CO2 sensor and utilizes a variable speed fan control to reduce systems flow;or exception applied YES C403.2.2.1 Ventilation If mechanically delivered,indicate that M001 ventilation systems are configured to provide not more than 150%of,but at least the minimum required volume of outdoor air to each zone per IMC,ASHRAE 62.1 or other applicable code(WAC,OSHA,etc.);or exception applied C403.2.2.1 Ventilation If delivered via natural ventilation,identify required elements per IMC including: minimum openable area to the outdoors or qualifying adjoining spaces;criteria for ensuring required ventilation is provided during all occupied hours of the year (including during inclement outdoor conditions) NA C403.2.2.2 Exhaust Indicate that exhaust systems are configured to provide not more than 150%of,but at least the minimum required volume from each zone per IMC,or other applicable code (WAC,OSHA,etc.);or exception applied NA C403.4.2.4 Exhaust system off- Refer to Requirements List section HVAC hour controls Controls for off-hour controls requirements for exhaust systems Page 9132 Mechanical Requirements • • 10 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.7.6.1 Balanced ventilation For Group R-2 dwelling and sleeping units, for Group R-2 indicate that each habitable space is provided occupancy with a balanced ventilation system;indicate system is provided with energy recovery with >_60%sensible recovery effectiveness NA C403.7.1.1 Demand control Identify spaces with ventilation provided by ventilation single zone system with air economizer;for each space indicate controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA C403.7.1.1 Demand control Provide list of spaces with IMC ventilation ventilation occupant load and the occupant outdoor airflow rate listed;for spaces with occupant load>_ 15 people/1,000 sf per IMC or occupant air flow rate>_ 15 cfm/person indicate controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception NA C403.7.2 Occupancy sensors For gyms,classrooms,auditoriums, conference rooms and other spaces with occupant load>_25 people/1,000 sf per IMC, that have an area>500 sf,indicate occupancy- based ventilation air control when space is unoccupied and method(closes outdoor air damper or shuts-off equipment);or alternate means provided to automatically reduce ventilation air when space is partially occupied;or exception applied NA C403.7.3 Ventilation air For ventilation air systems with supplemental heating control heating capacity that operate in conjunction with heating and cooling systems,indicate that ventilation air is tempered(via heating or heat recovery)to no greater than 55'F when the space conditioning system is in cooling mode C403.7.4.2 Ventilation controls Indicate method of ventilation and exhaust for Group R-1 isolation for each guest room and automatic guestrooms controls that are configured to turn off ventilation and exhaust airflow when each room is unoccupied C403.8.4 Group R occupancy Refer to Requirements List section Fans& exhaust fan efficacy Fan Controls C403.7.5 Enclosed loading For enclosed loading docks,indicate C403.7.5.1 dock ventilation ventilation/exhaust system method of activation(gas detection system for CO and NO2,or occupancy sensors),and control method(staged or modulating);if total ventilation system fan motor nameplate horsepower is>5 hp,indicate VSD or equivalent motor drives Page 10132 Mechanical Requirements • • 11 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.7.5 Enclosed parking For enclosed parking garages,indicate C403.7.5.2 garage ventilation ventilation/exhaust system activated by gas detection system for CO and NO2,and control method(staged or modulating);or exception applied;if total ventilation system fan motor nameplate horsepower is>5 hp, indicate VSD or equivalent motor drives NA C403.7.6.2 Ventilation/exhaust For systems with design ventilation air> systems energy 5,000 cfm,or design supply air cfm and% recovery ventilation air exceeding the values in Tables C403.7.6(1)or(2),indicate exhaust air energy recovery method;or exception applied with supporting calculations NA C403.7.6.2 Ventilation/exhaust For rooms served by multiple systems with systems energy aggregate design ventilation air>5,000 cfm, recovery or aggregate design supply air cfm and% ventilation air exceeding the values in Tables C403.7.6(1)or(2),indicate exhaust air energy recovery method;or exception applied with supporting calculations NA C403.7.6.2 Ventilation/exhaust Indicate energy recovery rated sensible systems energy recovery effectiveness>68%or a enthalpy recovery recovery ratio>60% C403.7.7.1.1 Kitchen exhaust hood Indicate on plans the type,duty,UL rating and C403.7.7.1.2 system exhaust airflow rate of each kitchen hood C403.7.7.1.3 C403.7.7.1.1 Kitchen exhaust hood Provide calculations that show a balanced C403.7.7.1.2 system accounting of total kitchen exhaust(include C403.7.7.1.3 all hoods)with%of:supply air,transfer air from adjacent spaces,and make-up air C403.7.7.1.1 Kitchen exhaust hood For hoods with make-up air drawn directly C403.7.7.1.2 system into the exhaust air cavity of each hood, C403.7.7.1.3 indicate that replacement air does not exceed 10%of hood exhaust airflow rate C403.7.7.1.1 Kitchen exhaust hood For kitchens with total hood exhaust C403.7.7.1.2 system exceeding 2,000 cfm,indicate that each hood C403.7.7.1.3 is UL 710 rated and maximum exhaust airflow rate of each hood is per Table C403.7.7.1.2;or exception applied C403.7.7.1.1 Kitchen exhaust hood For kitchens with total hood exhaust C403.7.7.1.2 system exceeding 2,000 cfm,indicate demand control C403.7.7.1.3 kitchen ventilation configured to a minimum 50%reduction in exhaust and replacement air system flows in response to alliance operation; or exception applied C403.7.7.2 Laboratory exhaust For buildings with total lab exhaust>5,000 systems energy cfm,indicate method of energy recovery used recovery to pre-condition laboratory make-up air; energy recovery effectiveness(min 25'F increase in outside air temperature);or alternative method per exception(VAV exhaust,semi-conditioned makeup,or CERM calculation) Page 11132 Mechanical Requirements • • 12 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.7.7.3 Transfer air For spaces where conditioned supply air is utilized as transfer air to balance mechanical exhaust,indicate basis of transfer airflow (supply required to meet loads,health/safety requirement,air that would normally be exhausted);or exception applied NA C403.7.8.1 Shutoff dampers for Indicate locations of outdoor air intake, C403.7.8.3 building isolation exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized,or gravity and exception applied (include leakage rating,cfm/sf) C403.7.8.1 Shutoff dampers for Indicate location of stairway and elevator C403.7.8.3 stairway and elevator hoistway shaft vent dampers on plans;verify hoistway shaft vents dampers are Class 1 motorized;or exception applied NA C403.7.8.2 Shutoff dampers for Indicate locations of return air dampers that C403.7.8.3 return air are integral to airside economizer operation; verify dampers are motorized;indicate whether dampers are Class 1,or within packaged equipment eligible for leakage rating exception(include leakage rating, cfm/sf) NA C403.7.8.4 Damper actuation Indicate automatic controls configured to close outdoor air intake,exhaust and relief outlet dampers during unoccupied equipment operation;not including economizer cooling, night flush or IMC required outdoor air/ exhaust C403.7.8.4 Damper actuation Indicate method of activation of stairway and elevator hoistway shaft vent dampers(fire alarm or interruption of power) C404.11.4 Exhaust system For buildings with pools or spas with water energy recovery for surface area>200 sf,indicate exhaust air heated indoor pools energy recovery method and use of waste heat and permanent spas (preheat ventilation air,pool water or service hot water);or exception applied C404.11.4 Exhaust system Indicate energy recovery system has the rated energy recovery for effectiveness and is configured to decrease heated indoor pools the exhaust air temperature at design and permanent spas conditions by>_36°F HVAC CONTROLS YES C403.4.1 Thermostatic controls Indicate locations of thermostatic and M203 (thermostats and humidity control devices and the zones they humidistats) serve on plans,including perimeter system zones Page 12132 Mechanical Requirements • • 13 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.4.1 Thermostatic controls Where adjacent(neighboring)zones are (thermostats and controlled by separate thermostats(including humidistats) perimeter systems used to offset heat gain or loss),and are connected by permanent openings> 10%of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes(one in heat,other in cool);applies to adjacent perimeter zones,adjacent nonperimeter zones,and adjacent perimeter and nonperimeter zones C403.4.1 Thermostatic controls If applying Exception 2 to interior zones (thermostats and adjacent to perimeter zones,indicate that humidistats) setpoints and deadband settings in these zones are coordinated so cooling in an interior zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating NA C403.4.1 Thermostatic If applying Exception 3 for DOAS,indicate controls(thermostats supply air temperature heating setpoint is<_ and humidistats) 65°F and cooling setpoint is>_72°F,or method of supply air temperature reset NA C403.4.1.1 Heat pump Indicate staged heating operation with supplementary heat compression as the first stage of heating and supplemental heating controlled with outdoor lock-out temperature set to 40°F or less,or indicate exception applied and specify equipment meeting the exception requirements C403.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling C403.4.1.3 Setpoint overlap If separate heating and cooling thermostatic restriction control devices are used to serve a zone, (thermostats) indicate locations of both thermostatic control devices and the zone they serve on plans C403.4.1.3 Setpoint overlap Indicate a limit switch,mechanical stop or restriction DDC control with programming to prevent (thermostats) simultaneous heating and cooling NA C403.4.1.4 Heated or cooled Indicate thermostatic controls within heating vestibules or cooled vestibules with a heating setpoint<_ 60°F and cooling setpoint>_85'F;indicate controls are configured to turn off heating when outdoor temperature is>45°F;or note exception applied NA C403.4.1.4 Heated air curtains Indicate controls are configured to turn off air curtain heating when outdoor temperature is> 450F Page 13132 Mechanical Requirements • • 14 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.4.1.6 Door switches for Doors required to have opening switches for HVAC system HVAC thermostatic control to the outdoors thermostatic control from a conditioned space and are>48 sf, indicate automatic controls configured to setback the HVAC system(s)when the door is open for>5 minutes;indicate method of HVAC system setback control(turns off the HVAC system or resets the heating setpoint to 55°F and cooling setpoint to 85'F),or exception applied(either C402.5.11 or C403.4.1.6) YES C403.4.2 Automatic setback Indicate zone thermostatic controls configured M001 C403.4.2.1 and shutdown with required automatic setback and manual C403.4.2.2 override functions,setback temperatures,and control method(automatic time clock or 7 day programmable controls);note exceptions applied NA C403.4.2.3 Automatic(optimum) Indicate all HVAC systems are provided with start and stop automatic start and stop controls;indicate start controls are configured to adjust the equipment start time as required to bring each area served up to design temperature just prior to scheduled occupancy;indicate stop controls are configured to reduce heating setpoint and increase cooling setpoint by at least 2°F prior to scheduled unoccupied periods NA C403.4.2.4 Exhaust system off- For exhaust systems serving conditioned hour controls spaces in all occupancies other than Group R, indicate method of control and that controls are configured to turn exhaust systems on and off in concert with the ventilation air systems providing their make-up air,or exception applied NA C403.4.2.5 Transfer and For transfer fan or mixing fan systems serving destratification fan conditioned spaces in all occupancies other system off-hour than Group R,indicate method of control and controls that controls are configured to turn fans on and off in concert with the associated HVAC systems,or exception applied NA C403.4.7 Combustion heating For combustion heating equipment other than equipment boilers or radiant heaters with output capacity >225,000 Btu/h,indicate modulating or staged combustion control NA C403.4.7.1 Combustion Indicate controls that are configured to limit decorative vented operation of combustion appliance,fireplace appliance, and fire pit to< 1 hour without override,or combustion fireplace that occupancy sensor controls are provided and fire pit controls Page 14132 Mechanical Requirements • • 15 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.7.4.1 Temperature setpoint For hotels/motels with over 50 guest rooms, controls for Group indicate automatic controls for HVAC R-1 guestrooms equipment serving guest rooms are configured to setback(heating)and set-up(cooling) temperature setpoint by at least 4°F when room is rented and unoccupied,and adjust setpoint to 60°F(heating)and 80°F(cooling) when room is unrented/vacated;indicate control method-activated by room entry, occupancy sensor or networked guestroom control system C403.7.4.2 Ventilation controls Refer to Requirements List section for Group R-1 Ventilation,Exhaust&Energy Recovery guestrooms C403.4.9 Thermostatic controls For primary space conditioning systems, C403.4.10 for Group R2/R3 indicate 5-2 programmable thermostats dwelling units and capable of two setback periods per day; Group R2 sleeping indicate each non-primary system is provided units with at minimum an adjustable thermostat,or exception applied.For all thermostats indicate purpose(heating only,cooling only,or both) and required temperature range;indicate thermostats are configured for at minimum a 5°F deadband NA C403.5.1 DX air handler For DX air handlers with cooling capacity variable cooling 65,000 Btu/h,indicate number of cooling control(Located stages provided and method(multiple under Integrated compressors and/or variable speed Economizer Control) compressors);indicate minimum displacement(capacity reduction)as%of full load;indicate thermostats are configured with the same number of cooling stages and displacement NA C403.5.1 DX air handler Indicate control method(cooling capacity variable cooling controlled in response to space temperature, control(Located space temperature controlled by modulating under Integrated supply airflow,or both) Economizer Control) NA C403.4.11.1 DDC system Provide central and zone level DDC controls C403.4.11.2 applications,controls as required based on system application, C403.4.11.3 and display capacity or size thresholds and other qualification per Table C403.4.11.1 NA C403.4.11.1 DDC system Identify all DDC system input/output control C403.4.11.2 applications,controls points in project documents C403.4.11.3 and display NA C403.4.11.1 DDC system Indicate control capability includes C403.4.11.2 applications,controls monitoring zone and system level demand for C403.4.11.3 and display fan pressure,pump pressure,heating and cooling;indicate capability to transfer demand information from zones to air/hydronic distribution system controllers,and to central plant systems and equipment controllers Page 15132 Mechanical Requirements • • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.4.11.1 DDC system Indicate system has the capability and is C403.4.11.2 applications,controls configured for trending and graphically C403.4.11.3 and display displaying input/output points NA C403.4.11.4 DDC demand For buildings with>780,000 Btu/h of response setpoint mechanical cooling,indicate controls are adjustment configured to automatically increase the cooling setpoint and decrease the heating setpoint>_2°F based upon a binary input to the control system approved by the utility NA C403.4.1.7 Demand responsive Indicate thermostatic controls for heating or controls cooling systems are provided with demand response controls are capable of increasing the cooling setpoint and decreasing the heating setpoint<_4°F;indicate the controls are capable of receiving and responding automatically to a demand response signal. NA C403.2.3 HVAC System Fault For buildings>_ 100,000 square feet,indicate detection and HVAC systems have fault detection and diagnostics diagnostics with sensors and communications to automatically identify HVAC system faults, provide prioritized recommendations for repair,and communicate faults and recommendations to remotely located authorized personnel. ADDITIONAL ENERGY EFFICIENCY MEASURE-DWELLING UNIT HVAC CONTROLS NA C406.2.1 Dwelling unit HVAC To comply with this additional efficiency controls credit,provide control design for a manual main control or occupancy sensor based controls,or provide control specification and product cut sheets demonstrating compliance with learning thermostat or geographic sensing options. ADDITIONAL EFFICIENCY CREDIT-FAULT DETECTION AND DIAGNOSTICS NA C406.2.2.7 Fault detection and To comply with this additional efficiency diagnostics credit,demonstrate HVAC controls comply with items 1 through 6 in Section C403.2.3; only buildings not required to comply with Section C403.2.3 or C403.6.10(16)can use this credit LOAD MANAGEMENT MEASURE-HVAC LOAD MANAGEMENT NA C406.3.2 HVAC load To comply with this additional efficiency management credit,indicate automatic controls connected to central DDC having digital input capable of being activated by external utility signal; where utility real-time demand or pricing program exists indicate system configured to utilize this signal;otherwise indicate building demand monitoring installed and controls configured to utilize demand signals Page 16132 Mechanical Requirements • • 17 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C406.3.2 HVAC load Indicate electric cooling controls configured management to gradually increase the cooling setpoint by at least 30F over 3 hours during summer peak periods;,indicate electric heating controls configured to gradually decrease the heating setpoint by at least 3°F over 3 hours during winter peak periods DUCTWORK,SHAFTS AND PLENUMS YES C403.10.1.1 Duct construction Indicate on plans that all ductwork is M001 C403.10.2 constructed and sealed per IMC NA C403.10.1.1 Duct construction For outdoor air ductwork,also indicate on C403.10.2 plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC YES C403.10.2.1 Duct pressure Identify location of low,medium and high M203 C403.10.2.2 classifications pressure ductwork on plans C403.10.2.3 NA C403.10.2.3 High pressure duct Indicate high pressure duct leakage testing leakage test requirements on plans;provide test results to jurisdiction when completed YES C403.10.1.1 Duct insulation For outdoor air ductwork located within M001 C403.10.1.2 conditioned space(upstream or downstream of shutoff damper),identify climate zone, duct airflow,and indicate ductwork insulation R-value per Table C403.10.1.1 on plans;or exception applied YES C403.10.1.1 Duct insulation For supply and return air ductwork located M001 C403.10.1.2 within unconditioned space or outdoors, identify climate zone and indicate ductwork insulation R-value per Table C403.10.1.2 on plans;or exception applied YES C403.10.1.1 Duct insulation For supply air ductwork located within M001 C403.10.1.2 conditioned space,identify on plans if design supply air temperature is<55°F or>105°F; indicate ductwork insulation R-value per Table C403.10.1.2 on plans;or exception applied YES C403.10.1.1 Duct insulation For return and exhaust air ductwork located M001 C403.10.1.2 within conditioned space(upstream of the shutoff damper)and downstream of an energy recovery media,indicate ductwork insulation R-value per Table C403.10.1.2;or exception applied YES C403.10.1.1 Duct insulation For exhaust and relief air ductwork located M001 C403.10.1.2 within conditioned space and downstream of the shutoff damper,indicate ductwork insulation R-value per Table C403.10.1.2;or exception applied NA C403.10.1.1 Shaft and plenum For outdoor air shafts and plenums,indicate C402.1.3 insulation on plans that the R-value of insulation on these elements complies with Table C402.1.3 for steel-framed walls Page 17132 Mechanical Requirements • • i of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com PIPING C403.10.3 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches)on hydronic piping plans;or exception applied C403.10.3.1 Protection of piping Indicate method of protection of pipe insulation insulation from damage/degradation on hydronic piping plans NA C403.10.4 HVAC refrigerant Indicate refrigerant piping insulation to be piping insulation installed on all hot gas lines and on some liquid lines per C403.10.4;indicate insulation conductivity<0.26 Btu x in/(h x ft2 x°F) ECONOMIZERS YES C403.5 Air economizer Identify all cooling systems requiring air M001 required economizer controls in equipment schedules on plans and in WSEC mechanical equipment compliance reports NA C403.5 Air economizer Indicate all systems utilizing air economizer exceptions exceptions in WSEC mechanical equipment compliance report,including those with water- side economizer in lieu of air economizer; indicate on plans and in WSEC mechanical equipment compliance reports all eligible exception(s)taken and measures to comply with exception(s) NA C403.4.1 Integrated Indicate air and water-side economizers are C403.5.1 economizer operation configured for partial cooling operation even -air and water where additional mechanical cooling is required to meet the load NA C403.4.1 Integrated For DX air handlers with single or multiple C403.5.1 economizer operation stages of mechanical cooling;indicate controls -air and water are configured with air economizer as the first stage of cooling NA C403.4.1 Integrated Refer to Requirements List section HVAC C403.5.1 economizer operation Controls for additional requirements for DX -air and water air handlers NA C403.5.2 Economizer heating Verify control method of HVAC systems with system impact-air economizers does not increase building and water heating energy usage during normal operation NA C403.5.3.1 Air economizer Indicate modulating outdoor air and return air capacity dampers are configured to provide up to 100%outdoor air for cooling NA C403.5.1 Air economizer Indicate that economizer controls are C403.5.3.2 controls and configured to provide partial economizer integrated operation cooling when additional mechanical cooling is also required to meet the cooling load NA C403.5.1 Air economizer Indicate that control of economizer dampers C403.5.3.2 controls and is not based only on mixed air temperature;or integrated operation exception applied for systems with cooling capacity<65,000 Btu/h Page 18132 Mechanical Requirements • • 19 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.5.3.3 Air economizer high Indicate high limit shut-off control method limit controls and required high limit per Table C403.5.3.3 NA C403.5.3.4 Relief of excess Refer to Requirements List section outdoor air Ventilation,Exhaust&Energy Recovery NA C403.5.3.4 Relief of excess Indicate relief air outlets are sized and outdoor air configured to relieve excess building air during air economizer operation to prevent building over-pressurization NA C403.5.3.4 Relief of excess Indicate relief air outlet are located to avoid outdoor air recirculation into the building C403.5.4.1 Water economizer For eligible systems where water-side capacity economizer may be provided in lieu of air economizer,indicate system is capable of 100%design cooling capacity at 50°F db/ 45°F wb outdoor air temperatures;indicate if threshold for 100%design cooling capacity via economizer must be lowered to 45°F db/ 40°F wb due to dehumidification requirements C403.5.4.2 Water economizer Indicate that the pressure drop across maximum pressure precooling coils and heat exchangers in water drop economizer systems do not exceed 15 feet (4572 mm) NA C403.5.5 DX equipment For DX air handlers with economizer and economizer fault cooling capacity>_54,000 Btu/h,provide a detection and fault detection and diagnostics(FDD)system diagnostics to monitor economizer system operation and report faults HYDRONIC SYSTEMS-EQUIPMENT SELECTION&PERFORMANCE C403.3.2.3 Maximum air cooled For chilled water plants and buildings with> chiller capacity 500 tons of cooling capacity,indicate air- cooled chiller capacity is< 100 tons,or exception applied C403.3.2.2 Large capacity For buildings>_300 tons of cooling capacity, cooling systems indicate method of multi-stage or variable capacity control(VSD,multiple staged compressors,or max capacity of any single unit C403.3.2.4 Non-standard water- For water-cooled centrifugal chillers not cooled centrifugal designed for operation at standard conditions, chillers provide calculations documenting maximum full load and part load rated equipment performance requirements C403.3.3 Hot gas bypass For cooling equipment with hot gas bypass, limitation for chillers provide either multiple step unloading or continuous capacity modulation;indicate bypass capacity per Table C403.3.3 C403.4.3 Large capacity boiler For hydronic systems with only a single boiler C403.3.4.4 systems that has>500,000 Btu/h input capacity, indicate multi-stage or modulating burner Page 19132 Mechanical Requirements • • 20 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.4.3 Large capacity boiler For boiler system(single or multiple)with> C403.3.4.4 systems 1,000,000 Btu/h input capacity,indicate turndown ratio per Table C403.3.4.4 and method(multiple single input boilers, modulating boilers,or combination) NA C403.3.4.1 Large capacity boiler For all boiler systems with input capacity>_ systems 2,500,000 Btu/h and all systems where one stack serves 2 or more boilers with a combined input capacity>_2,500,000 Btu/h, indicate combustion air positive shut-off is provided to restrict airflow through the combustion chamber during standby(e.g.flue or vent damper). NA C403.3.4.2 Large capacity boiler For boiler systems with combustion air fans> systems 10 hp,indicate variable speed fan NA C403.3.4.3 Large capacity boiler For boiler systems with input capacity>_ systems 5,000,000 and a steady state full-load combustion efficiency<90 percent,indicate combustion air volume to be automatically controlled to limit stack-gas oxygen concentrations specified in Table C403.3.4.3. List exception if it applies. NA C403.3.4.5 High capacity space For gas hot water space heating systems with C403.3.4.5.1 heating gas boiler >_ 1,000,000 Btu/h and< 10,000,000 Btu/h C403.3.4.5.2 system(new capacity,indicate boiler thermal efficiency>_ buildings) 90 percent;coils and heat exchangers sized at design conditions to have a boiler return water temperature<_ 120°F;values and controls to ensure under all operating conditions the water temperature entering the boiler is<_ 120°F or the supply water recirculating directly into the return system is<20 percent of design flow of the operating boilers. C403.2.4 Variable flow For pump motors>_5 hp,indicate method of capacity-pumps variable flow control(VSD or equivalent method)in equipment schedule,or exception applied NA C403.3.7 Hydronic system flow Indicate chilled water and condenser water rate flow types and operating hours,and maximum flow rates in less than or equal to Table C403.3.7. NA C403.3.8.1 Chilled-water coil Indicate chilled-water coils sized to provide a selection 15°F difference between leaving and entering water temperature and a minimum 57°F leaving water temperature at design conditions.,or exception applied NA C403.3.8.2 Hot-water coil Indicate hot-water coils sized to provide a selection 20°F difference between leaving and entering water temperature and a maximum I I8°F entering water temperature at design conditions.,or exception applied Page 20132 Mechanical Requirements • • 21 of 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C403.4.12 Pressure independent For heating and cooling water coils with a control valves design flow>5 gpm,indicate modulating pressure independent control values are provided HYDRONIC SYSTEMS-CONTROLS C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.3.2 Two-pipe changeover Indicate changeover deadband is> 15°F systems outdoor air temperature;indicate controls are configured so that heating/cooling modes are active for at minimum 4 hours before changeover and that the delta between heating /cooling supply temperatures at changeover point is C403.4.1.5 Heating water For hot water boilers that provide building temperature setback heating via one-or two-pipe systems,indicate controls that provide heating water temperature setback based on outdoor temperature C403.4.4 Hydronic system part For heating and chilled water systems with>_ load controls and 300,000 Btu/h output capacity,indicate supply-water system controls are configured to temperature reset automatically reset supply water temperature based upon demand;or exception applied C403.4.4 Hydronic system part Indicate automatic pump flow controls are load controls and configured to reduce system flow rate by supply-water 50%,or the maximum allowed by the temperature reset equipment manufacturer,based upon the heating or cooling loads;or describe why not required C403.4.4 Hydronic system part For hydronic systems with output capacity Z load controls and 300,000 Btu/h that serve heating water supply-water systems,chilled water systems and water- temperature reset cooled unitary air conditioners,indicate that pumps are provided with a variable speed drive if one of the following conditions apply: 1)System pump motor hp is>_2 hp and pumps are designed to operate continuously or per time schedule;2)System pump motor hp is>_7.5 hp and pumps are controlled by automatic DDC configured to only operate pumps when there is a call for zone heating or cooling C403.4.4 Hydronic system part Where variable speed drives are required, load controls and indicate system is configured so that pump supply-water motor power is<30%of design wattage at temperature reset 50%of design flow rate;indicate pump flow is controlled to maintain one control valve nearly wide open,or to maintain a minimum differential pressure;or exception applied Page 21132 Mechanical Requirements • • 22 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.4.6 Hydronic system For individual pumps required to have variable pump flow variable speed controls,indicate manner of control pump speed control(differential pressure, static pressure setpoint,zone heating or cooling demand,or based on the relationship between variable speed controller frequency and power) C403.4.5 Chiller/boiler plant Indicate controls are configured to pump isolation automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use C403.4.3.3.1 Water loop heat Indicate method of water loop temperature pump-temperature control(central plant equipment controls are deadband configured to provide>_20'F water supply temperature deadband between heat rejection and heat addition modes,or controls are configured for system loop temperature optimization C403.4.3.3.2 Water loop heat Indicate type of cooling tower(open-or pump-heat rejection closed-circuit)in equipment schedule; equipment indicate whether the cooling tower is used directly in the heat pump loop or in conjunction with a separate heat exchanger; indicate method used to limit system heat loss when heat rejection is not needed C403.4.3.3.3 Water loop heat For hydronic heat pump systems with total pump-isolation system power> 10 hp,indicate 2-way valves isolation valves on each heat pump and variable flow system control HEAT REJECTION SYSTEMS-EQUIPMENT SELECTION&PERFORMANCE C403.9.1.3 Centrifugal fan open- For open-circuit centrifugal fan cooling circuit cooling towers towers with>_ 1,100 gpm capacity,indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers HEAT REJECTION&RECOVERY-CONTROLS C403.9.1.1 Fan speed control For each fan powered by an individual motor C403.9.1.2 or array of motors,with total connected fan power>_5 hp(including motor service factor),indicate method of automatic fan speed control(adjusted based on leaving fluid temperature or condenser temperature/ pressure of heat rejection device);verify fan selection provides<_30%design wattage at 50%design airflow C403.9.1.1 Fan speed control For multiple-cell heat rejection equipment C403.9.1.2 with VSD,indicate controls are configured to ramp all fans in unison(not staged on/off operation) Page 22132 Mechanical Requirements • • 23 of 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.9.1.4 Cooling tower flow For open-circuit cooling towers configured turndown with multiple-or variable-speed condenser water pumps,indicate system is designed so all cells can be run in parallel;indicate method of condenser pump turn down control C403.9.2.1 Heat recovery for For buildings with 24-hour operation and> service water heating 1,500,000 Btu/h of heat rejection capacity and design service hot water load>250,000 Btu/h,indicate condenser heat recovery to pre- heat service water;or exception applied. Provide calculations showing the amount of recovered heat that is utilized(60%of peak heat rejection load or pre-heat service water to 85°F). C403.9.2.2 Steam condensate For buildings with on-site steam heating systems heat recovery systems,indicate condensate water heat recovery and use of recovered heat C403.9.2.2 Steam condensate For buildings that use off-site generated steam systems heat recovery where condensate is not returned to the source,indicate on-site condensate water heat recovery C403.9.2.3 Refrigeration For buildings with food service,meat or deli condenser heat departments that have>_500,000 Btu/h of recovery remote refrigeration capacity for coolers/ freezers,indicate condenser heat recovery and use of captured energy(service water heating, space heating,or dehumidification reheating) C403.9.2.3 Refrigeration For buildings with>40,000 sf conditioned condenser heat floor area and>_ 1,000,000 Btu/h of remote recovery refrigeration capacity,indicate condenser heat recovery to pre-heat service water;indicate remaining recovered heat is applied to space heating or dehumidification reheating C403.9.2.4 Condenser heat For buildings that operate>70 hour per week, recovery for space that are not served by a DOAS with energy heating recovery,and have> 1,500,000 Btu/h of heat rejection capacity and z 0.45 cfm per sf of design minimum supply airflow with reheat, indicate condenser heat recovery is provided for space heating that complies with Sections C403.9.2.4.1 or C403.9.2.4.2 or C403.9.2.4.4 C403.9.2.4.1 Water to water heat Indicate that 90%or more of the total C403.9.2.4.4 recovery building space heating and ventilation air design loads are served by heat energy rejected from either a heat recovery chiller or the cooling loop of water to water heat pump equipment C403.9.2.4.2 Exhaust heat recovery Indicate that waste heat is recovered from least 90%of the total building exhaust airflow such that leaving exhaust air temperature while in heat recovery mode is 55'F dry bulb; note exhaust air systems eligible for exception to this requirement Page 23132 Mechanical Requirements • • 24 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.9.2.4.3 Process heat recovery In spaces with 5 watts per sf year-round cooling loads from lights and equipment, indicate these spaces are served by water- cooled equipment configured for heat recovery C403.9.2.4.3 Process heat recovery If these spaces are served by economizer(air or water),indicate automatic controls are configured to disable economizer operation while system is in heat recovery mode ADDITIONAL ENERGY EFFICIENCY MEASURE-IMPROVED LOW CARBON DISTRICT ENERGY SYSTEMS(10%) NA C406.2.2.4 Improved low-carbon Provide calculations showing 90%or more of district energy the annual service water and space heat systems(10 percent energy use or 90%or more of the annual better). service water heat,space heat and space cooling energy use is met by a district energy exchange system complying with C406.2.2.4.1 or a district energy heating and/or cooling system complying with C406.2.2.4.2;provide documentation the system is operational and is in accordance with this section prior to the final inspection. NA C406.2.2.4.1 Improved low-carbon Provide calculations and documentation that district energy 45%of the annual district-system-net-load- exchange systems(10 met(sum of heating and cooling energy percent better) provided to attached buildings)comes from heat recovery between connected buildings, waste heat,or renewable energy resources; and no more than 25%of the annual heat input to the system comes from fossil fuel or electric-resistance sources. NA C406.2.2.4.2 Improved low-carbon Provide calculations and documentation that district energy distribution losses are less than or equal to 5% heating and cooling of the annual load delivered to buildings or heating only served by the system;and that the system systems(10 percent complies with one of the following: 1)45%of better) the annual district-system-net-load-met(sum of heating and cooling energy provided to attached buildings)comes from heat recovery between connected buildings,waste heat,or renewable energy resources and no more than 25%of the annual heat input to the system comes from fossil fuel or electric-resistance sources,or,2) 10%or less of the system annual heat input to the system comes from fossil fuels,electric-resistance sources,or heat pump sources with an annual COP<3 ADDITIONAL ENERGY EFFICIENCY MEASURE-IMPROVED LOW CARBON DISTRICT ENERGY SYSTEMS(20%) Page 24132 Mechanical Requirements • • 25 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com NA C406.2.2.5 Improved low-carbon Provide calculations showing 90%or more of district energy the annual service water and space heat systems(20 percent energy use or 90%or more of the annual better). service water heat,space heat and space cooling energy use is met by a district energy exchange system complying with C406.2.2.4.1 or a district energy heating and/or cooling system complying with C406.2.2.4.2;provide documentation the system is operational and is in accordance with this section prior to the final inspection. NA C406.2.2.5.1 Improved low-carbon Provide calculations and documentation that district energy 50%of the annual district-system-net-load- exchange systems(20 met(sum of heating and cooling energy percent better) provided to attached buildings)comes from heat recovery between connected buildings, waste heat,or renewable energy resources; and no more than 10%of the annual heat input to the system comes from fossil fuel or electric-resistance sources. NA C406.2.2.5.2 Improved low-carbon Provide calculations and documentation that district energy distribution losses are less than or equal to 5% heating and cooling of the annual load delivered to buildings or heating only served by the system;and that the system systems(20 percent complies with one of the following: 1)50%of better) the annual district-system-net-load-met(sum of heating and cooling energy provided to attached buildings)comes from heat recovery between connected buildings,waste heat,or renewable energy resources and no more than 25%of the annual heat input to the system comes from fossil fuel or electric-resistance sources,or,2) 10%or less of the system annual heat input to the system comes from fossil fuels,electric-resistance sources,or heat pump sources with an annual COP<4 LOAD MANAGEMENT MEASURE-COOLING ENERGY STORAGE NA C406.3.5 Cooling energy To comply with this additional efficiency storage credit,indicate automatic controls connected to central DDC having digital input capable of being activated by external utility signal; where utility real-time demand or pricing program exists indicate system configured to utilize this signal;otherwise indicate building demand monitoring installed and controls configured to utilize demand signals NA C406.3.5 Cooling energy Provide calculation of ice or chilled water storage storage capacity with standby loss< 1.5%per day;indicate automatic controls to activate storage to reduce peak period electric demand;provide calculation of storage capacity MULTIPLE ZONE AIR SYSTEMS Page 25132 Mechanical Requirements • • • of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.6.1 Air systems serving Identify supply air systems serving multiple multiple zones zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control;or provide supporting documentation for applied exception to VAV C403.6.1 VAV air terminal Provide equipment schedules on plans that list primary supply all VAV air terminals and types(fan-powered airflow series and parallel air terminals,single duct and dual duct air terminals,etc.) C403.6.1 VAV air terminal For each air terminal include:maximum primary supply primary supply airflow rates during zone peak airflow heating and zone peak cooling;maximum terminal airflow during reheating,recooling or mixing;minimum ventilation airflow rate,and the basis for these values;if IMC or ASHRAE 62.1 multiple zone equation is the basis for minimum flow rates,provide this calculation on plans C403.6.2 Single duct VAV Indicate single duct terminal units are terminal units configured to reduce primary supply air before reheating or recooling C403.6.3 Dual duct systems- For systems with separate warm air and cool terminal units air ducts,indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct C403.6.8 VAV system static- Indicate locations of duct static pressure C403.6.9 pressure sensors and sensors on plans;include at least one sensor DDC set points per major duct branch;verify controller setpoint pressure at each sensor is<_ 1.2 inch w.g. C403.6.8 VAV system static- For systems with zone level DDC,indicate C403.6.9 pressure sensors and controls are configured to monitor zone DDC set points damper positions and reset static pressure setpoint based on the zone requiring most pressure;include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic,and allows building operators to exclude zones from reset logic C403.6.4 VAV system supply Indicate controls automatically reset supply air reset air temperature in response to building loads or outdoor air temperature;or exception applied NA C403.6.4 VAV system supply Indicate zones expected to experience air reset relatively constant loads and that maximum air flow is designed to deliver peak capacity at the fully reset supply air temperature. C403.6.5 Multiple-zone VAV For systems with zone level DDC controls, system ventilation indicate controls are configured to optimization controls automatically reduce outdoor airflow in response to changes in system ventilation efficiency;or exception applied Page 26132 Mechanical Requirements • • 27 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.6.6 Parallel fan powered Indicate controls automatically activate or VAV air terminals shut off the air terminal fan based on call for heating and/or ventilation;indicate controls are configured to activate the terminal fan as the first stage of heating prior to activating the heating coil;indicate control method of primary air during warmup or temperature setback mode HIGH EFFICIENCY MULTIPLE-ZONE VAV SYSTEMS-EXCEPTION TO C403.3.5 DOAS,MUST COMPLY WITH ALL 15 PROVISIONS TO BE ELIGIBLE C403.6.10, Minimum area served Indicate that each high efficiency multiple- Item 1 and zoning zone VAV systems serves an area>_3,000 sf and includes>_5 zones C403.6.10, Air economizer Indicate system is configured for 100%air Item 2 economizer operation and complies with all related economizer requirements per C403.5 (without economizer exceptions) C403.6.10, Direct digital controls Provide DDC controls for all components of Item 3 (DDC) system per C403.4.11 (regardless of system size);identify all DDC system input/output control points;indicate capability for trending and graphical display C403.6.10, Supply and outdoor For systems with minimum required outdoor Items 4 and 5 airflow measurement air>2,500 cfm,provide an airflow and control monitoring station that is configured to measure outdoor air intake under all load conditions;indicate control sequence that increases or reduces outdoor air cfm based on VAV terminal feedback of ventilation efficiency(per C403.6.5 without exceptions) or and DCV(per C403.7.1) C403.6.10, Supply and outdoor Provide a supply airflow monitoring station Items 4 and 5 airflow measurement that is configured to measure supply air and control delivered to VAV terminals under all load conditions C403.6.I0,I Zone isolation and Verify maximum area served by a single VAV tem 6 maximum area served system is<_50,000 sf,or one entire floor, whichever is greater;in addition if a system serves>25,000 sf,that includes areas that are expected to be occupied non-simultaneously, indicate zone isolation controls per C403.2.1 C403.6.10, Interior/exterior Verify that VAV terminals serving interior Item 7 zone design supply air cooling driven loads are sized per a design temperature supply air temperature that is 5'F higher than VAV terminals serving exterior zones while in cooling mode C403.6.10, Maximum air Identify all air terminals with minimum Item 8 terminal inlet velocity primary airflow setpoints>50%of maximum setpoint in mechanical equipment schedule for these air terminals indicate inlet velocity does not exceed 900 fpm Page 27132 Mechanical Requirements • • i of 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.6.10, Maximum allowable For each fan system serving a multiple-zone Item 9 system brake VAV HVAC,provide calculations that verify horsepower fan system electrical input power is<_90%of the fan power budget in accordance with Section C403.8.1.1 C403.6.10, Fan-powered terminal Indicate all series and parallel fan-powered Item 10 unit motor and terminals have electronically commutated control motors(ECM);indicate DDC control system is configured to vary air terminal fan speed as a function of the load;indicate fan speed during periods of low heating,low cooling,or ventilation-only mode is<66%of peak design air flow,or provide supporting documentation for applied exception C403.6.10, Application of single Indicate VAV terminal types on plans;verify Item 11 duct and fan-powered fan-powered terminal units only serve terminal units perimeter zones with envelope loads and interior zones with high occupant density and DCV per C403.7.1;verify all other zones are served by single duct terminal units C403.6.10, Fan-powered terminal Indicate DDC controls are configured to Item 12 unit primary air reset automatically reset the primary supply air cfm setpoint of all fan-powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband mode, based upon the VAV air handling unit minimum ventilation air fraction C403.6.10, Controls for high For zones> 150 sf with high occupant density Item 13 occupant density (>_25 people/1000 sf),indicate zone is spaces served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint based on measured CO2;also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by>_5°F when space in unoccupied C403.6.10, Dedicated cooling For data centers and server,electronic Item 14 systems serving data equipment,telecom or similar spaces with centers and server, design cooling loads>5 W/sf,indicate spaces electronic equipment are served by dedicated cooling systems that and telecom spaces are independent of the HPVAV systems serving the rest of building C403.6.10, Dedicated cooling Indicate dedicated cooling systems are Item 14 systems serving data configured for 100%air economizer centers and server, operation and comply with all related electronic equipment economizer requirements per C403.5(without and telecom spaces economizer exceptions),or heat recovery per C403.5,Exception 9 C403.6.10, Central plant Indicate whether systems are served by a high Item 15 efficiency efficiency heating water plant,or a high efficiency chilled water plant Page 28132 Mechanical Requirements • • 29 of 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.6.10, Central plant if complying via high efficiency heating water Item 15 efficiency plant:Indicate all VAV terminals have hydronic heating coils served by a heating water system with either gas-fired boiler(s) with thermal efficiency(Et)Z 92%,air-to- water heat pumps,or heat recovery chillers; indicate hydronic heating coils are sized per a maximum 120°F entering water temperature during peak demand C403.6.10, Central plant If complying via high efficiency chilled water Item 15 efficiency plant:Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25%per Table C403.3.2(7) (note water-cooled IPLV is max,all others are min);indicate smallest chiller or compressor in plant is<20%of the total plant capacity, or provide thermal storage sized for>20%of total plant capacity C403.6.10, Fault detection and Indicate DDC system includes automatic fault Item 16 diagnostics detection and diagnostics(FDD)configured to monitor operation and provide fault reporting of all required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HIGH EFFICIENCY SINGLE-ZONE VAV SYSTEMS-EXCEPTION TO C403.3.5 DOAS,MUST COMPLY WITH ALL 8 PROVISIONS TO BE ELIGIBLE C403.12, Air economizer Indicate system is configured for 100%air Item 1 economizer operation and complies with all related economizer requirements per C403.5 (without economizer exceptions) C403.12, Direct digital controls Provide DDC controls for all components of Item 2 (DDC) system per C403.4.11 (regardless of system size);identify all DDC system input/output control points;indicate capability for trending and graphical display C403.12, Outdoor airflow For systems with minimum required outdoor Item 3 measurement and air> 1,000 cfm,provide an airflow control monitoring station that is configured to measure outdoor air intake under all load conditions;indicate controls that adjust outdoor air cfm via DCV per C403.7.1 C403.12, Maximum allowable For each fan system serving a single-zone Item 4 fan power VAV system,provide calculations that verify fan system electrical input power is<_90%of the fan power budget in accordance withC403.8.1.1 C403.12, Supply airflow Provide controls that adjust supply airflow Item 5 control based on the heating and cooling loads; indicate control sequence that limits minimum fan speed to 30%of peak design airflow or required ventilation during unoccupied mode, whichever is less Page 29132 Mechanical Requirements • • 30 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.12, Controls for high For zones> 150 sf with high occupant density Item 6 occupant density (>_25 people/1000 sf),indicate DCV control spaces that resets ventilation setpoint based on measured CO2;also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by>_5°F when space in unoccupied C403.12, High efficiency Indicate which system performance option is Item 7 system option applied-high efficiency DX cooling and heat pump or high efficiency gas heating;or heating coils served by a high efficiency heating water plant;or cooling coils served by high efficiency chilled water plant C403.12, High efficiency If complying via high efficiency DX:Indicate Item 7 system option full load and part load rated cooling efficiency exceeds WSEC listed efficiency by at least 15%;if heating is supplied by a gas-fired furnace,indicate thermal efficiency(Et)is>_ 90%;if system is a heat pump,indicate heating efficiency(HSPF or COP)exceeds WSEC listed efficiency by at least 10%; control of cooling and heating coil output shall be configured with a minimum of 2-stages or modulating C403.12, High efficiency If complying via high efficiency heating water Item 7 system option plant:Indicate hydronic heating coils are served by a heating water system with either gas-fired boiler(s)with thermal efficiency (Et)>92%,air-to-water heat pumps,or heat recovery chillers;indicate hydronic heating coils are sized per a maximum 120°F entering water temperature during peak demand C403.12, High efficiency If complying via high efficiency chilled water Item 7 system option plant:Indicate cooling coils are served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.3.2(7)(note water-cooled IPLV is max,all others are min);indicate smallest chiller or compressor in plant is<_ 20%of the total plant capacity,or provide thermal storage sized for>_20%of total plant capacity C403.12, Fault detection and Indicate DDC system includes automatic fault Item 8 diagnostics detection and diagnostics(FDD)configured to monitor operation and provide fault reporting of all required parameters for all HPVAV single-zone air systems EXTERIOR HEATING SYSTEMS C403.11.1 Heating outside a Indicate systems providing hearing in non- building enclosed outdoor occupied spaces are radiant systems Page 30132 Mechanical Requirements • • 31 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C403.11.1 Heating outside a Indicate occupancy sensing or timer switch building controls configured to automatically shut off heating system when area served is unoccupied C403.11.2 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F C403.11.3 Freeze protection Indicate automatic controls to shut off system system controls when outdoor temperature exceeds 40°F,or conditions protect fluid from freezing HVAC EQUIPMENT ENERGY USE METERING NA C409.3.1 HVAC equipment For new buildings and building additions> energy use metering 25,000 sf,verify energy use metering of all equipment used to provide space heating and cooling,dehumidification and ventilation will be provided per C409;indicate equipment eligible for exception DOCUMENTATION AND SYSTEM SPECIFIC REQUIREMENT TO SUPPORT COMMISSIONING(CX) C408.1 Scope of mechanical For buildings with areas required to comply systems with C403.3.5(DOAS)or with>_ 180,000 commissioning Btu/h total output cooling capacity or >240,000 Btu/h total output heating capacity or energy recovery equipment>_300 cfm, indicate that all mechanical systems regardless of individual capacity are required to be commissioned;or provide building heating/ cooling capacity calculation demonstrating eligibility for exception C408.1 Scope of mechanical Indicate that all systems,equipment and systems controls for which the WSEC requires control commissioning functions and/or configuration to perform specific functions are included in the Cx scope C408.1.1 Commissioning Indicate in plans and specifications that Cx C408.1.4.1 requirements in per C408 is required for all applicable construction mechanical systems documents C408.1.1 Commissioning Include general summary that includes at C408.1.4.1 requirements in minimum:narrative description of activities, construction responsibilities of the Cx team,schedule of documents activities including verification of project close out documentation per C103.6,and conflict of interest plan(if required) C408.1.1 Commissioning Include in general summary that a Cx project C408.1.4.1 requirements in report or Compliance Checklist(Figure construction C408.1.4.1)shall be completed by the documents Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Page 31132 Mechanical Requirements • • 32 of 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2025 NEEA,All rights reserved The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the Washington State Energy Code,Commercial Provisions. For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com C408.1.2.2 Functional Identify in plans and specifications the performance testing intended operation of all equipment and criteria controls during all modes of operation, including interfacing between new and existing-to-remain systems C408.2.2 Air system and Indicate in plans that air and fluid flow rates hydronic system shall be tested and balanced within the balancing tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses,then adjusted to meet design flow conditions C408.2.2.1 Air system balancing Indicate devices that provide the capability to devices balance all supply air outlets,zone terminals and air handling equipment requiring system balancing C408.2.2.2 Hydronic system Indicate devices that provide the capability to balancing devices isolate,balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps;or exception applied PROJECT CLOSE OUT DOCUMENTATION YES C103.6 Documentation and Indicate in plans that project close out M001 project close out documentation and training of building submittal operations personnel is required for all requirements mechanical components,equipment and systems governed by this code;indicate close out documentation shall include:record documents,O&M manuals,applicable WSEC mechanical equipment compliance reports and calculations Page 32132