18725 67TH AVE NE_PA26-0153_2026
DA Area:::: �,l.69 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ S 06 I Design Area 7 Wei System EA Roo SALON TENANT SPACE ATIO Demand Calculations using Hazen-Williams Method Occupancy Classification: LH JI Design Area Density: 0.1 x m Additional Outside Hose: 250 Design Area Size: 1500 Notes: PER NFPA#13 2019 S I I AREA OF WORK TA ION I 72 T I I II I SCOPE OF WORK BY BURNS FIRE SYSTEMS THIS SUBMITTAL IS FOR THE MODIFICATION OF SPRINKLER PROTECTION TO EXISTING SPACE TO 70 CONFORM WITH NEW CEILING PLAN. SPACING OF SPRINKLERS IN ACCORDANCE WITH NFPA#13. ALL N EXISTING SYSTEM RISER ROOM NEW EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH NFPA STANDARDS. 1 7 NEW OR REPLACED SPRINKLERS TO MATCH K-FACTOR, TEMPERATURE RATING, FINISH AND KEY PLAN RESPONSE CHARACTERISTICS OF EXISTING SPRINKLERS. S 1 / 1 SCALE: N.T.S. S T N 7 0 0 (18) TOTAL RELOCATED 70 PENDANT HEADS SUPPLIED FROM EXISTING 1" 13 OUTLETS t70 02 , (2) TOTAL ADDED > 1 NEW PENDANT HEADS SUPPLIED FROM NEW MECHANICAL TEE SPRINKLERS SPACED IN ROOMS IN ACCORDANCE WITH NFPA 13 SMALL ROOM RULE 061 10.2.5.2.3*The requirements of 10.2.5.2.1 shall not apply within small rooms as defined in 710 3.3.196 4�s 10.2.5.2.3.1 sprinklers shall be permitted to be located not more than 9 ft(2.7 m)from any single wall. 10.2.5.2.3.2 sprinkler spacing limitations of 10.2.5 and area limitations of Table 10.2.4.2.1(a) \ 1 shall not be exceeded. 7 S T 1 STATION 9 S1 ALL PIPING SHOWN IS EXISTING AND TO REMAIN U.N.O. - City of Arlington o R s Building Department 1 7 APPROVED Calculation results for Design Area 7 - SALON TENANT SPACE Kevin Olander-02/26/2026 This system as shown on company print no dated No changes authorized unless approved by for Ironwood Apartments Building 1 at 18725 67th Ave NE S7 2 the Building Official contract no is designed to discharge at a rate of 0.1 gpm/ft2(L/min/m2)of floor area over R a maximum area of 1500 ft2 when supplied with water at a rate of 263.3 gpm at 60.1 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: LH Number of heads flowing: 15 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 22.17 ft/s Storage arrangement: Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 60.1 psi Flow from Overhead sprinklers: 263.3 gpm Pressure Available at Source: 78.8 psi — - Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 18.8 psi Flow from Outside Hoses: 0 gpm i (A" t3' Other fixed flows: 0gpmTotal flow in system piping: 263.3 gpm Additional flow at/beyond source: 250 gpmL-4Total of all flows: 513.3 gpm OFIRE PROTECTIONPLAN Floor First N CERT. #151760 Jennifer Yates C.E.T. N.I.C.E.T. Level III N NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN DATE DESCRIPTION BY BFPS, INC Ironwood Bldg 1 Salon T. I, E7- WASNINOTONSTATE� ������ SYM CNT POSITION FINISH TEMP K NPT SIN MPG. MODEL PERMIT NO. W O E 31'� FIRE SPRINKLER SYSTEMS E TENCY ®'zo PENo WHITE Tss s.eo /z vKsoz wKwc vKsoz David Yates P.O.B. 1110 18725 67th Ave NE David aces Level3 • CONTRACT No. GRANITE FALLS, WA APPROVAL CITY OF ARLINGTON . Bums Fire Protection Systems,Inc. : Arlington, WA 98223 S ; BURNSFPS41 qU ; DRAWN By J. V-0" 2;9i26 � 425-388-0124 SCALE 1/4" = 1'-0" DATE 2/9/26 Dole DESIGN QUESTIONS 360-580-1062 CONTRACTOR: RNSED FP 1 PLOTTED Agftk FIRE SPRINKLER PERMIT APPLICATION sw Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Type of Permit: ❑ New Installation 10 System Modification ❑ Phased Installation Property Address: 18725 67th Ave N E Suite No.: Project Valuation: Lot#: Parcel ID No.: 31052300200500 Preferred Contact: 0 Owner 0 Applicant O Contractor Project Description: Owner Name: Grandviews Ironwood Place LLC Phone No.: Email Address: gv@grandview Cell No.: 20505 Olympic PI NE Ste 101 Mailing Address: city: Arlington State: WA Zip: 98223 Applicant Name: Keith Kyle I Audra Williams Phone No.: O - 360-691-2235 Email Address: keith(a-_)burnsfire.com I audrap_burnsfire.com Cell No.: K - 425-905-5780 Mailing Address: PO Box 1110 City: Granite Falls State: WA zip: 98252 Contractor Name: Burns Fire Protection Systems, Inc. Office No.: 360-691-2235 Email Address: keith@burnsfire.com I audra@burnsfire.com Cell No.: 425-905-5780 Mailing Address: PO Box 1110 City: Granite Falls State: WA Zip: 98252 L&I Contractor License Number: BURNSFP841 DU Expiration Date: 12-31-2026 SUBMITTAL REQUIREMENTS:Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: ❑ Complete and Scaled Plans ❑ Hydraulic Calculations ❑ Equipment Specifications for Each Fire Sprinkler Permit Application ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) **DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers,Valves, Pull Stations,and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00&over—based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application-review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 375 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = 49 $600.00 + $ _ $ 375.00 Hydraulically Designed Systems Yes ® / No ❑ Yes=Permit Fee x 2 $ 375.00 PERMIT FEE SUBTOTAL $750.00 NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices= $625.00 + Is I _ $ Hydraulically Designed Systems Yes ❑ / No ❑ Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26+ $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced SO% _ $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I-new or existing x $150.00 = $ Class II-new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS(105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No.of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $750.00 PLAN REVIEW FEE $272.29 Processing/Technology Fee $25.00 TOTAL $ 1,047.29 1 hereby certify that I am the ❑Owner, ®Applican4 ®Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Keith Kyle 02-09-2026 Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 CALCULATION SUMMARY Project Name: Ironwood Apartments Building 1 Project Location: 18620 Woodlands Way Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ftz) (psi) (gpm) # (gpm) (psi) 7 Demand (HW) LH 1500 513.3 Required 0.1 9 16.8 15 250 18.8 60.1 •.....•.•..•...••..............• Expkes WASHINGTON STATE a 31.26 CERTIFICATE OF COMPETENCY; • FIRE SPRINKLER SYSTEMS e David Yates 2805-0898-C Level • Burns Fire Protection Systems, Inc. BURNSFP841 U ' a 2/9/26 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Date 2/9/2026 Building 1.dwg Page 1 Copyright©2002-2012 Tyco Fire Protection Products HYDRAULIC CALCULATIONS for Job Information Project Name: Ironwood Apartments Building 1 Contract No. : City: Arlington, WA 98223 Project Location: 18620 Woodlands Way Date:2/9/2026 Contractor Information Name of Contractor: Address: City: Phone Number: E-mail: Name of Designer: Authority Having Jurisdiction: Design Remote Area Name 7 Remote Area Location SALON TENANT SPACE Occupancy Classification LH Density(gpm/ft2) 0.1 Area of Application(ft2) 1500 Coverage per Sprinkler(ft2) 168 Number of Calculated Sprinklers 15 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 513.3 Required Pressure at Source(psi) 60.1 Type of System Wet Volume-Entire System (gal) 7221.3 gal Water Supply Information Date Location CITY OF ARLINGTON Source W 1 Notes PER NFPA#13 2019 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job: Ironwood Apartments Building 1 Node Labels: Off Pipe Labels: Off Diagram for Design Area : 7 (Optimized Hvdraulic Simolified) File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 3 Job: Ironwood Apartments Building 1 Hydraulic Analysis for : 7 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.8 513.3 60.1 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) 250 Other(custom defined) Hose Flow(gpm) ...............................................................................................I............................................................................................................................................................................................................................................................................................................................................ Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 263.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 ............................................................................................................................................................................................................................................................................................................................................................................................................................................. Total Sprinkler Flow(gpm) 263.3 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 60.1 W1 -Flow(gpm) 263.3 Demand w/o System Pump(s) N/A File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job: Ironwood Apartments Building 1 Hydraulic Analysis for : 7 a Supply i Supply;Safety Pressure f System Demand f Add.Out. Hose O Available At Source 100 78.8 psi @ 513.3 gpm 80 _ �_�► S2 7 —�-.�� ���� 63.493 D2 Q 6 D3 —� L 7 50 N N d d 40 30 20 D1 1 0 0 15002000 2500 3000 3500 4000 4500 5000 550 Flow, gpm File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Date 2/9/2026 Building 1.dwg Page 5 Copyright©2002-2012 Tyco Fire Protection Products Job: Ironwood Apartments Building 1 Hydraulic Analysis for : 7 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 5.6 D2 System Demand 263.3 60.1 D3 System Demand+Add.Out.Hose 513.3 60.1 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.9 309.3 18.8 513.3 Supply;Safety Pressure 71 290.9 10.9 513.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ftz) (gpm) (psi) (gpm/ft2) (gpm) (psi) 701 Overhead 168 5.6 0.1 16.8 9 0.1 16.8 9 Sprinkler 702 Overhead 168 5.6 0.1 16.8 9 0.101 17 9.2 Sprinkler 703 Overhead 168 5.6 0.1 16.8 9 0.1 16.8 9 Sprinkler 704 Overhead 168 5.6 0.1 16.8 9 0.101 17 9.2 Sprinkler 705 Overhead 168 5.6 0.1 16.8 9 0.103 17.3 9.6 Sprinkler 706 Overhead 168 5.6 0.1 16.8 9 0.101 16.9 9.2 Sprinkler 707 Overhead 168 5.6 0.1 16.8 9 0.104 17.5 9.8 Sprinkler 708 Overhead 168 5.6 0.1 16.8 9 0.104 17.5 9.8 Sprinkler 709 Overhead 168 5.6 0.1 16.8 9 0.105 17.7 9.9 Sprinkler 710 Overhead 168 5.6 0.1 16.8 9 0.107 18 10.3 Sprinkler 711 Overhead 168 5.6 0.1 16.8 9 0.105 17.6 9.8 Sprinkler 712 Overhead 168 5.6 0.1 16.8 9 0.108 18.2 10.6 Sprinkler File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 713 Overhead 168 5.6 0.1 16.8 9 0.109 18.3 10.7 Sprinkler 714 Overhead 168 5.6 0.1 16.8 9 0.111 18.6 11 Sprinkler 715 Overhead 168 5.6 0.1 16.8 9 0.108 18.2 10.6 Sprinkler File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job: Ironwood Apartments Building 1 Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft 9pm/psil/2 gpm ft2 psi psi gpm gpm/ft2 psi gpm 701 Overhead Sprinkler 5.6 16.8 168 9 9 10 HEAD Open 0 0.1 -5.6 16.8 703 Overhead Sprinkler 5.6 16.8 168 9 9 10 HEAD Open 0 0.1 -5.6 16.8 706 Overhead Sprinkler 5.6 16.9 168 9.2 9 10 HEAD Open 0.1 0.101 -5.6 16.8 704 Overhead Sprinkler 5.6 17 168 9.2 9 10 HEAD Open 0.2 0.101 -5.6 16.8 702 Overhead Sprinkler 5.6 17 168 9.2 9 10 HEAD Open 0.2 0.101 -5.6 16.8 705 Overhead Sprinkler 5.6 17.3 168 9.6 9 10 HEAD Open 0.5 0.103 -5.6 16.8 707 Overhead Sprinkler 5.6 17.5 168 9.8 9 10 HEAD Open 0.7 0.104 -5.6 16.8 708 Overhead Sprinkler 5.6 17.5 168 9.8 9 10 HEAD Open 0.7 0.104 -5.6 16.8 711 Overhead Sprinkler 5.6 17.6 168 9.8 9 10 HEAD Open 0.8 0.105 -5.6 16.8 709 Overhead Sprinkler 5.6 17.7 168 9.9 9 10 HEAD Open 0.9 0.105 -5.6 16.8 710 Overhead Sprinkler 5.6 18 168 10.3 9 10 HEAD Open 1.2 0.107 -5.6 16.8 715 Overhead Sprinkler 5.6 18.2 168 10.6 9 10 HEAD Open 1.4 0.108 -5.6 16.8 712 Overhead Sprinkler 5.6 18.2 168 10.6 9 10 HEAD Open 1.4 0.108 -5.6 16.8 713 Overhead Sprinkler 5.6 18.3 168 10.7 9 10 HEAD Open 1.5 0.109 -5.6 16.8 714 Overhead Sprinkler 5.6 18.6 168 11 9 10 HEAD Open 1.8 0.111 -5.6 16.8 100 Node 10.5 12.29 NODE -6.6 097 Node 10.5 12.29 NODE -6.6 102 Node 10.5 12.29 NODE -6.6 094 Node 10.7 12.29 NODE -6.6 105 Node 10.7 12.29 NODE -6.6 003 Node 11.2 12.29 NODE -6.6 072 Node 11.5 12.29 NODE -6.6 068 Node 11.5 12.29 NODE -6.6 075 Node 11.6 12.29 NODE -6.6 065 Node 11.7 12.29 NODE -6.6 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job: Ironwood Apartments Building 1 Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft 9pm/psi1/2 gpm ft2 psi psi gpm gpm/ft2 psi gpm 061 Node 12.1 12.29 NODE -6.6 086 Node 12.3 12.29 NODE -6.6 084 Node 12.4 12.29 NODE -6.6 128 Node 12.5 12.29 NODE -6.6 131 Node 12.5 12.29 NODE -6.6 135 Node 12.6 12.29 NODE -6.6 121 Node 12.8 12.29 NODE -6.6 138 Node 13 12.29 NODE -6.6 030 Node 20.9 12.29 NODE -6.6 035 Node 21.2 12.29 NODE -6.6 169 Node 22.2 12.29 NODE -6.6 175 Node 24.2 12.29 NODE -6.6 658 Node 39.3 12.29 NODE -6.6 662-0 Node 46.4 6.24 NODE -4 662-I Node 47.9 5.92 NODE -3.9 663 Node 51.7 3.5 NODE -2.8 666-0 Node 52.5 2.73 NODE -2.5 666-I Node 58.2 0.73 NODE -1.6 667 Node 58.3 0.5 NODE -1.5 669 Node 60 -3 NODE 0 672 Node 60.1 -3 NODE 0 671 Node 60.1 -3 NODE 0 W1 Supply -263.3 60.1 -3 SUPPLY 0 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job: Ironwood Apartments Building 1 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 701 10 5.6 16.8 1 lx(tee-Br)=5 19.54 120 9 Flex-48" 097 12.29 16.8 1.049 1x(90 ell)=2 7 0.0939 -1 26.54 2.5 097 12.29 7.5 1.5 12 120 10.5 094 12.29 24.3 1.728 0 0.0164 0 12 0.2 094 12.29 16.9 1.5 lx(tee-Br)=11.29 25.2 120 10.7 086 12.29 41.3 1.728 11.29 0.0437 0 36.49 1.6 086 12.29 0 2 10 120 12.3 084 12.29 41.3 2.203 0 0.0134 0 10 0.1 084 12.29 29.8 2 10 120 12.4 121 12.29 71.1 2.203 0 0.0366 0 10 0.4 121 12.29 17.5 2 2x(tee-Br)=27.28 180.14 120 12.8 175 12.29 88.6 2.203 27.28 0.055 0 207.41 11.4 175 12.29 174.8 2 lx(tee-Br)=13.64 22.84 120 24.2 658 12.29 263.3 2.203 13.64 0.4138 0 36.48 15.1 658 12.29 0 2.5 2x(90 ell)=12.79 16.54 120 39.3 662-0 6.24 263.3 2.705 12.79 0.1523 2.6 29.33 4.5 662-0 6.24 0 2.5 0.32 46.4 Btfly149225 662-I 5.92 263.3 0 0 4.2489 0.1 *** 0.32 1.4 662-I 5.92 0 2.5 lx(tee-Br)=16.07 2.42 120 47.9 663 3.5 263.3 2.705 16.07 0.1523 1 18.49 2.8 663 3.5 0 4 lx(tee-Br)=23.41 4.77 120 51.7 666-0 2.73 263.3 4.31 23.41 0.0158 0.3 28.19 0.4 666-0 2.73 0 4 2 52.5 Ames 666-I 0.73 263.3 0 0 2.4252 0.9 Deringer 30 2 4.9 *** 666-I 0.73 0 4 0.23 120 58.2 667 0.5 263.3 4.31 0 0.0158 0.1 0.23 0 667 0.5 0 6 lx(tee-Br)=43.72 45.5 140 58.3 669 -3 263.3 6.4 1x(90 ell)=17.45 61.17 0.0017 1.5 106.67 0.2 669 -3 -50.9 12 98 140 60 671 -3 212.5 12.64 0 0.0000 0 98 0 671 -3 50.9 12 0.5 140 60.1 W 1 -3 263.3 12.64 0 0.0001 0 0.51 1 0 W1 60.1 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job: Ironwood Apartments Building 1 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 703 10 5.6 16.8 1 lx(tee-Br)=5 19.54 120 9 Flex-48" 102 12.29 16.8 1.049 1x(90 ell)=2 7 0.0939 -1 26.54 2.5 102 12.29 9.4 1.5 12 120 10.5 105 12.29 26.2 1.728 0 0.0189 0 12 0.2 105 12.29 17 1.5 10 120 10.7 003 12.29 43.2 1.728 0 0.0475 0 10 0.5 003 12.29 17.3 1.5 lx(tee-Br)=11.29 98.46 120 11.2 030 12.29 60.5 1.728 11.29 0.0887 0 109.75 9.7 030 12.29 0 2 10 120 20.9 035 12.29 60.5 2.203 0 0.0272 0 10 0.3 035 12.29 58.4 2 10 120 21.2 169 12.29 119 2.203 0 0.095 0 10 0.9 169 12.29 55.8 2 10.48 120 22.2 175 12.29 174.8 2.203 0 0.1937 0 10.48 2 175 24.2 Path No: 3 706 10 5.6 16.9 1 lx(tee-Br)=5 19.54 120 9.2 Flex-48" 094 12.29 16.9 1.049 1x(90 ell)=2 7 0.0954 -1 26.54 2.5 094 10.7 Path No: 4 704 10 5.6 17 1 lx(tee-Br)=5 19.54 120 9.2 Flex-48" 105 12.29 17 1.049 1x(90 ell)=2 7 0.0957 -1 26.54 2.5 105 10.7 Path No: 5 702 10 5.6 17 1 lx(tee-Br)=5 18.79 120 9.2 Flex-48" 100 12.29 17 1.049 5 0.0958 -1 23.79 2.3 100 12.29 -7.5 1.5 6.47 120 10.5 102 12.29 9.4 1.728 0 0.0028 0 6.47 0.0 102 10.5 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job: Ironwood Apartments Building 1 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 6 705 10 5.6 17.3 1 lx(tee-Br)=5 19.54 120 9.6 Flex-48" 003 12.29 17.3 1.049 1x(90 ell)=2 7 0.0993 -1 26.54 2.6 003 11.2 Path No: 7 707 10 5.6 17.5 1 lx(tee-Br)=5 19.54 120 9.8 Flex-48" 072 12.29 17.5 1.049 1x(90 ell)=2 7 0.1015 -1 26.54 2.7 072 12.29 -5.3 1.5 12 120 11.5 075 12.29 12.3 1.728 0 0.0046 0 121 1 0.1 075 12.29 17.6 1.5 lx(tee-Br)=11.29 25.2 120 11.6 084 12.29 29.8 1.728 11.29 0.0239 0 36.49 0.9 084 12.4 Path No: 8 708 10 5.6 17.5 1 lx(tee-Br)=5 19.54 120 9.8 Flex-48" 068 12.29 17.5 1.049 1x(90 ell)=2 7 0.1016 -1 26.54 2.7 068 12.29 5.3 1.5 12 120 11.5 065 12.29 22.8 1.728 0 0.0145 0 12 0.2 065 12.29 17.7 1.5 10 120 11.7 061 12.29 40.5 1.728 0 0.0421 0 101 1 0.4 061 12.29 18 1.5 lx(tee-Br)=11.29 98.46 120 12.1 035 12.29 58.4 1.728 11.29 0.083 0 109.75 9.1 035 21.2 Path No: 9 711 10 5.6 17.6 1 lx(tee-Br)=5 19.54 120 9.8 Flex-48" 075 12.29 17.6 1.049 1x(90 ell)=2 7 0.102 -1 26.54 2.7 075 11.6 Path No: 10 709 10 5.6 17.7 1 lx(tee-Br)=5 19.54 120 9.9 Flex-48" 065 12.29 17.7 1.049 1x(90 ell)=2 7 0.103 -1 26.54 2.7 065 11.7 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job: Ironwood Apartments Building 1 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 11 710 10 5.6 18 1 lx(tee-Br)=5 19.54 120 10.3 Flex-48" 061 12.29 18 1.049 1x(90 ell)=2 7 0.1062 -1 26.54 2.8 061 12.1 Path No: 12 715 10 5.6 18.2 1 lx(tee-Br)=5 19.54 120 10.6 Flex-48" 128 12.29 18.2 1.049 1x(90 ell)=2 7 0.1089 -1 26.54 2.9 128 12.29 -0.8 1.5 lx(tee-Br)=11.29 25.2 120 12.5 121 12.29 17.5 1.728 11.29 0.0089 0 36.491 1 0.3 121 12.8 Path No: 13 712 10 5.6 18.2 1 lx(tee-Br)=5 19.54 120 10.6 Flex-48" 131 12.29 18.2 1.049 1x(90 ell)=2 7 0.1089 -1 26.54 2.9 131 12.29 0.8 1.5 12 120 12.5 135 12.29 19 1.728 0 0.0103 0 12 0.1 135 12.29 18.3 1.5 12 120 12.6 138 12.29 37.2 1.728 0 0.0361 0 12 0.4 138 12.29 18.6 1.5 lx(tee-Br)=11.29 108.46 120 13 169 12.29 55.8 1.728 11.29 0.0764 0 119.751 1 9.1 169 22.2 Path No: 14 713 10 5.6 18.3 1 1x(tee-Br)=5 19.54 120 10.7 Flex-48" 135 12.29 18.3 1.049 1x(90 ell)=2 7 0.1099 -1 26.54 2.9 135 12.6 Path No: 15 714 10 5.6 18.6 1 1x(tee-Br)=5 19.54 120 11 Flex-48" 138 12.29 18.6 1.049 1x(90 ell)=2 7 0.1132 -1 26.54 3 138 13 File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job: Ironwood Apartments Building 1 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 16 669 -3 0 12 2x(90 ell)=94.86 882.87 140 60 672 -3 50.9 12.64 10x(45ell)=228.37 323.24 0 0 1206.1 0 672 -3 0 12 1x(tee-Br)=105.4 94.1 140 60.1 671 -3 50.9 12.64 105.4 0 0 199.51 1 0 671 60.1 Path No: 17 100 12.29 0 1.5 5.53 120 10.5 097 12.29 7.5 1.728 0 0.0019 0 5.53 0.0 097 10.5 Path No: 18 072 12.29 0 1.5 12 120 11.5 068 12.29 5.3 1.728 0 0.001 0 12 0.0 068 11.5 Path No: 19 128 12.29 0 1.5 12 120 12.5 131 12.29 0.8 1.728 0 0.0000 0 12 0 131 12.5 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 22.17 ft/s occurs in the following pipe(s): (658-175) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job: Ironwood Apartments Building 1 Device Graphs Pressure vs. Flow Function Design Area:7; Supply Ref.:W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 a 50 N 45 N N 40 d 35 30 25 20 l5 10 5 0 0 00 0 0 0 0 N o 0 0 0 Flow,gpm Pressure Loss Function Design Area: 7; BFP Ref.: 1022 (Ames Deringer 30, Size = 4); Inlet Node: 666-I; Outlet Node: 666-0 17.15 16.15 15.15 14.15 13.15 12.15 N 11.1 Z 10.15 N 3 9.1 1A y 8.1 Il 7.1 6.1 4.9 psi @ 263.3 gpm 5.1 4.1 3.1 2.1 1.1 0.1 0 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm File:D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright©2002-2012 Tyco Fire Protection Products Page 15 Job: Ironwood Apartments Building 1 Device Graphs Pressure Loss Function Design Area: 7; Valve Ref.: 1021 (Btfly149225, Size= 2.5); Inlet Node: 662-I; Outlet Node: 662-0 2s 2.3 .N a ti 1-8 w 1.4 psi @ 263.3 gpm Yl N d 3 0.8 0.3 Flow,gpm File: D:\dwg2\burns\1 Apartment Projects\Ironwood Apartments Building 1 Arlington\Salon TI\Ironwood Apartments Building 1.dwg Date 2/9/2026 Copyright @ 2002-2012 Tyco Fire Protection Products Page 16 Burns Fire Protection Systems, Inc. P.O. Box 1110 Granite Falls, WA 98252 PH: (425) 388-0124 Ironwood - Salon TI 18725 67th Ave NE Arlington, WA 98223 Item No DESCRIPTION MANUFACTURER MFG. NO. FINISH REMARKS Sprinkler Head Viking VK302 Flex Hose Victaulic AH2 Chr Steel Pipe Bull Moose Sch 10/40 1 Eddy Flow Blk Sammy Screw All Buildex Hangers Caddy Grooved Coupling Victaulic 009H Orange Grooved Fitting Victaulic Orange Mech Tee Tyco 730 Orange Threaded Fittings Shurjoint Blk Page 1 of 6 ® MICROFAST° QUICK NIKJNG4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfast° Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) 2. LISTINGS AND APPROVALS c6l. cULus Listed: Category VNIV M FM Approved: Class Series 2000 vds VdS Approved: Certificates G414009 and G414010 LPCB Approved LPCB C C CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Viking Technical Data may be found on Rated to 175 psi (12 bar)water working pressure The Viking Corporation's Web site at Factory tested hydrostatically to 500 psi (34.5 bar) http://www.vikinggroupinc.com. Thread size: 1/2" NPT, 15 mm BSP The Web site may include a more recent Nominal K-Factor: 5.6 U.S. (80.6 metric"*) edition of this Technical Data Page. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) `cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, and ENT=JN Temperature Suffix: 135 °F (68 °C) =A, 155 °F (68 °C)= B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C)= G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C)temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Form No. F_033314 Rev 14.1 (New Page) Page 2 of 6 ® MICROFAST° QUICK NIKJNG4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A%"ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast°Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat Clip JR Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 14.1 Page 3 of 6 N41KJNG4 ® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature z Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. a The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE,and ENT coatings. For ENT coated automatic sprinklers,the waterway is coated Sprinkler wrench 16036W/B** for recessed pendent sprinklers **A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F_033314 Rev 14.1 Page 4 of 6 ® MICROFAST° QUICK NIKJNG4 RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY The Viking Microfast®Quick Response q1zFinish Pendent Sprinkler VK302 Escutcheon(if applicable) Maximum 175 PSI(12 Bar)WWP Base Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Part SIN p Style (Refer also to Design Criteria.) Number NPT BSP U.S. metricz Inches mm cULus" I VdS I LPCB I C L`' 12979 VK302 Pendent 1/2" 15 mm 5.6 1 80.6 2-1/4 58 A1Z, B1Y,C2X, D2 I A3 I A3Z,B3Y I D3Z,C3Y Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 1 X - Standard surface-mounted escutcheon or the °C), 200 OF(93°C),286 OF(141 °C) - Brass, Chrome, White Viking Micromatic°Model E-1 Recessed Escutcheon B- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 Polyester Black Polyester Y - Standard surface-mounted escutcheon or the °C), and 200 OF(93°C) and Black PTFE 2-ENT' Viking Microfast® Model F-1 Adjustable Escutcheon, or C- 155 OF (68 °C), 175 OF (79 °C), and 200 OF 3 - Brass, Chrome, White recessed with the Viking Micromatic° Model E-1 or E-2 (93-C) Polyester56, and Black Recessed Escutcheon D- 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 Polyester56 Z - Standard surface-mounted escutcheon or the °C),286 OF(141 °C) Viking Microfast°Model F-1 Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Other approvals may be in process. ^Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. s Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. DESIGN CRITERIA- UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast°Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 14.1 Page 5 of 6 N41KJNG4 ® MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast®Quick Response ;�Finish Pendent Sprinkler VK302 A1xF Escutcheon(if applicable) Maximum 175 PSI (12 Bar)WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' Style NPT I BSP U.S. metric2 Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 112" 15 mm 5.6 80.6 2-1A 58 A1Z,B1Y, D2X,C2 Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200 °F Viking Micromatic® Model E-1 Recessed (93°C), 286°F(141 °C) Approved Finishes Escutcheon B- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1-Brass,Chrome,White Polyester", Y - Standard surface-mounted escutcheon or the 200°F(93°C) and Black Polyester' Viking Microfast°Model F-1 Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2-ENT5 or recessed with the Viking Micromatic®Model E-1 °F(141 °C) or E-2 Recessed Escutcheon D- 155°F(68°C), 175°F(79°C),200°F(93°C) Z - Standard surface-mounted escutcheon or the Viking Microfast®Model F-1 Adjustable Escutcheon Footnotes ' Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfast®Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Form No. F_033314 Rev 14.1 Page 6 of 6 G MICROFAST° QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) _N411UW4J The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ceiling Opening Size: mm) 2-5/16" (58.7 mm) minimum (15 m 1/ 2-1/2" (63.5 mm) maximum N PT` 2-1/8" l (54 mm) T T 1-1/2 2-1/4" F i 1-3/4" 2" (38 mm) (57 mm) (51 mm) Min. (44.5 mm) Max. - .�•e� Installed with a standard Installed with a Microfast Note:At maximum,adapter is 1/8" surface-mounted Model F-1 Adjustable exposed 1/2"(12.7 mm)from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Ceiling Opening Size: ___ 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" 2-1/8" (54 mm) (54 mm) f 1-1/8" ♦ 1-1/8" 1-377 /4" (28.6 mm) 2"" (28.6 mm) (44.5 mm) -" Min. (51 mm) Min. Max. Max. r� Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 Rev 14.1 (New Page) Victaulic° VicFlexT" Sprinkler Fittings ✓ctaullcg Series AH2 and AH2-CC Braided Flexible Hoses 10.85 &Flex TM I Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1'YDN25 ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.757140 mm straight reducer. Series AH2-CC 17DN25 ID Braided Hose: 31, 36, 48, 60, 727790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. Connections • From Branchline • 3/4720mm BSPT female thread (VdS only) • 11/4"/32mm BSPT female thread (LPCB only) • 1725mm NPT or BSPT female Thread • 1725mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) • No. 116 CPVC Adapter (1"/25mm Female CPVC Socket x 1725mm Grooved IGS) • No. 142 Welded Outlet • Style 922 Outlet-T • Style 920N Mechanical-T Outlet • No. 65 Grooved End of Run Fitting • Hose Inlet • 1725mm Grooved IGS • 1725mm NPT or BSPT male thread • 3/4720mm BSPT male thread (VdS only) • 11/4"/32mm BSPT male thread (LPCB only) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 10.85 5839 Rev AL Updated 02/2022 0 2022 Victaulic Company.All rights reserved. 1 Actaull& victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) • Sprinkler Reducer • Sprinkler Connection: 1/2" and 3/4Y15mm and 20mm NPT or BSPT female thread • Straight Lengths: 5.75", 9", 137140mm, 230mm, 330mm • 90' Elbows • Standard Short • Low Profile Short • Standard Long • Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB10 for Armstrong@ TechZone'" ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90' low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm. • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature • 225°F/107°C • 150°F/650C (No. 116 CPVC Adapter) Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) • 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius • T/178mm (FM/CCCf Approval) • 2751 mm (cULus Listed) • T/76.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaul;c° victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors • FM (1/2715 mm reducer) K5.6/8,1 (S.I.), (3/4/20 mm reducer) K14.0/20,2 (S.I.) • cULus (1/2715 mm reducer) K8.0/11,5 (S.I.), (3/4/20 mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2715mm reducer) K5.6/8,1 (S.I.), (3/4Y20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS FM C@ US VdS OLpCB CCC V ` E LISTED �G 2809 NOTE • The VicFlex Series AH2 Hose has been tested and evaluated by Spears@ for acceptable use with Spears@ CPVC Products and is therefore covered under the Spears@ FlameGuard@ Installer Protection Plan. 3.0 SPECIFICATIONS — MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (1/2 Y15 mm or 3/4720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (1/2 Y15 mm or 3/4720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:' Grade "E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. ' Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Item Description z 1 Flexible Hose 5 1 6 g 7 3 4 9 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple A 6 Braid B 7 Collar/Weld Fitting 8 Sleeve 9 Reducer Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose Item Description 1 Flexible Hose iL 2 Isolation Rin 6 B 7 3 4 (4) 3 Gasket 4 Nut _ 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting A 8 Sleeve B 9 Reducer Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1219 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaul�c° victaulic.com 4.0 DIMENSIONS (CONTINUED) Standard Reducer 5.755/140 mm straight reducer Optional Reducers 2.62/ —s 66.5 mm 2.627 66.5 mm 7.257 184.2 mm 5.50"/ 6.577 139.7 mm � 166.9 mm 0"/ � 127.7.0 mm 9.07229 mm straight reducer 4.837 3.25v 122.7 mm 82.6 mm I 13.07330 mm straight reducer Short 90'elbow reducer Long 90'elbow reducer NOTE • The Short 90'elbow reducer is typically used with concealed sprinklers while the longer 90'elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile 5.257 J11 "/ 133 mm 3.507 3m 2.84"/ 89 mm 92 1.887 72 mm 48 mm Lmrn / 1.4"/36 mm Short 90'elbow reducer Long 90'elbow reducer NOTE • Style AB11:When low profiles elbows are with the Style AB11 bracket,the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter �Lto� NOTES • E to E is 3.0"/76.0 mm • The No. 116 CPVC Adapter has 2 ft.(0.6 m)EQL of 1"Schedule 40 pipe. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic° victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB2 s • Suspended Ceilings • Hard-Lid Ceilings a z Item Description 1 24"/610mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed Style AB3 • Surface Mount Applications • FM/LPCB Approved Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system 3 Item Description 1 24"/610mm or 48"/1219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket s 3 End Bracket for Hat Furring Channel NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaul�c° victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610mm or 48"/1219 mm Square Bar 2 2 Patented Vertically Adjustable Center Bracket 3 End Bracket ® n NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed. Style AB7 3 • Suspended Ceilings I • Hard-Lid Ceilings Item Description z 1 24"/610mm or 48'71219 mm Square Bar 2 Patented 1-Bee2®Center Bracket ® t 3 End Bracket NOTE • Both sizes FM/VdS/LPCB Approved. 3 Style AB7 Adjustable 3 • Suspended Ceilings • Hard-Lid Ceilings z Item Description t 1 700mm or 1400mm Square Bar 2 Patented 1-Bee20 Center Bracket 3 End Bracket(adjustable) NOTE • Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctaul�c° victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB10 • Suspended ceilings 3 2 • Armstrong®TechZone" ' ® ® 3 Item Description 1 6"/152 mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved,cULus listed. 3 Style AB11 • Suspended ceilings • Hard-Lid ceilings z Item Description 1 24"/610mm or 48"/1219 mm Square Bar 1 2 Patented 1-Bee2®Center Bracket 3 End Bracket 3 NOTE • FM/VdS Approved,cULus listed. Style AB12 •-� z • Suspended ceilings .. • Hard-Lid ceilings Item Description \ 1 t le A1312 Bracket Body 2 #2 Square Drive Set Screw NOTE • FM/VdS Approved. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaul�c° victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount • Cantilever mount • Temporary mount in exposed ceilings z Item Description 1 Style ABBA M unting Plate 2 Style ABBA Square Bar 3 Cap Screw,Serated Flange,M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body 5 Cap Screw,Serated Flange,M6 x 1 x 15.24, ° T25 Torx Drive Recessed NOTE • FM Approved. Style ABMM 2 • Surface mount • Stand-off mount ®® Item Description �O i 1 Style ABMM Bracket Body 2 Cap Screw,Serated Flange,M6 x 1 x 15.24, T25 Torx Drive Recessed NOTE • FM Approved. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 9 ✓ctaul�c° victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket rR See�T Table L Bracket Assembly Style AB2 II II 437 Ill r 23/s"/60.33 mm rn M 2— 2750.80 mm 5/e"/1 5 9 mm 1.7/43 mm i Typical ceiling grild T Finished' surface See note 247610 mm or 48'71219 mm on Center V2707 3/4"A 9 MM MAX.RECESS V2707 MAX.EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4" 1/2'. 3/4.. 1/2" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4"Max Recess 1/2"Max Recess 3/4"Max Recess 1/2"Max Recess inches inches inches inches inches inches inches inches Minn I mm mm mm mm mm mm MM "R"Minimum 2.0 3.0 7.0 —Bend Radius 50 80 175 "A"Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space NOTE 0 Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 (D 2022 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctaulic° victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket R See chart A See Chart Bracket #10 Screw Assembly 3 Style AB2 2'%e768 mm �1.874 mm max.hole I I 21/B760 mm l l min.hole 2"x 4" I I I 9 Stud I I I 3/z„/ 89mm I p Q I I I I I I I I I Finished SA°/16 mm — Typical 167406 mm C/C ceiling Typical drywall V38'/z"/13 mm MAX.RECESS V38 MAX.EXTENSION Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4"1 20mm 1/2"1 13mm 3/4'1 20mm 3/4'1 20mm 1/2"1 13mm 3/4"1 20mm 3/4'1 20mm 1/2'1 13mm 3/4"1 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 11 1 7.0 Bend Radius 50 80 175 "A"Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4'1 20mm 3/4"1 20mm 1/2"1 13mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R"Minimum Bend Radius "A"Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 11 ✓ctaulic° victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket R See chart A See Chart Bracket assembly Style AB4 a II II 4.1 V 21/e'"/60 mm Typical Hat i 104 mm max.hole Channel I 2r 2"/51 mm #10Screw grid 1 min.hole II II — II EEC '/8723 mm I Finished ,U ceiling 1/8716 mm Typical drywall Typical 167406 mm C/C V271/4'719 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/a' 1/i' 3/a" 1/i' V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4'Max Recess 1/2"Max Recess 3/4'Max Recess 1/2"Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R"Minimum 2.0 2.0 3.0 3.0 7.0 7.0 _ Bend Radius 50 50 80 80 175 175 "A"Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctaul�c° victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket R See chart A See chart Bracket assembly ly Style ABS 23/ 57 mm 2'/e"/60mm 2"x max.hole 1I 1 - 1 1 i 35/e'/ 2"/51 mmmetal stud � 92 mm min.hole II II II II II II II II 9— II II II II II II II II I Finished 1/8716 mm ceiling Typ.Drywall Typical16"/406 mm C/C V27IW719 mm MAX.RECESS V27 MAX.EXTENSION Hose Clearance Chart _ Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4"120mm 1/2"113mm 3/4'120mm 3/4"120mm 1h"113mm 3/a"120mm 3/4"120mm 1/2"113mm 3/4"120mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R"Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A"Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 3/4"120mm 1/2"113mm 3/4"1 20mm 1/2"1 13mm 1/2"1 13mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R"Minimum Bend Radius "A"Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctaulic° victaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 21/8760 mm 21%6768 mm 11 Bracket max.hole max.hole Assembly 2751 mm 21/8760 mm A Style AB11 min.hole min.hole See Chart 6 m 76 mm ff ff II II 1.7"/43 mm Finished 1m m4am Typical 1/8715.9 mm ceiling face ceiling grid Typical ceiling tile See Note 247610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 3/4!'120mm 1/2"1 13mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaulic° victau|ic.com 4.9 DIMENSIONS Clearances Style 4Bl2 and ABBABracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight5757I40mm Reducer Ceiling Face 11A inch/ Nominal length Unfinished lee"T:a'ble A inch/ 2. —_ "=m 3 m Sel� i i 'i 'B'SeeTabla Finished Face of Typical Ceiling Typical Ceiling =,",°r,,,°°MAX.RECESS ,no *n° MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer Recessed* Concealed Recessed Concealed oncealed Recessmemd Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches Bottom f Gate ~Adjvmam/xv will u*limited Style ABK8N4Bracket Stand-off Dimensions 2.227 3.937 0.287 r"1947 loomm 75 mm m.8os83y Rev m' Updated o2/e02u 0u02uvictaulic Company.All rights reserved. victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C 33/a/ 95.3 mm I a 3 2 B A 'I 23/a"/60 m m max.hole 2"/51 mm min.hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm mm mm WaliThickness 2 4 6 8 10 2 4 6 8 10 "A" 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 "C" 294 376 478 243 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 1 300 Bend Radius 7 8 "R" 0 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 16 ✓ctaulic° victaulic.com 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart + rchart AA See chartee chart %A ero (i, 1/8i3,7 Style 922 Threaded Style 922 Mechanical Tee Grooved Outlet Mechanical Tee Outlet + 2750 mm 2/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R Bend Radius 80 100 125 150 175 R Bend Radius 80 100 125 150 175 A Min. 9.4 10.4 11.4 12.4 13.4 A Min. 7.7 8.7 9.7 10.7 11.7 238 263 289 314 339 197 222 247 273 298 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 17 '✓ctaulic° victaulic.com 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart A A See chart See chart i®9ce ro i Female Threaded Weld Outlet No.142 Grooved Weld Outlet 2750 mm 2750 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm Minimum 3 4 5 6 7 Minimum 3 4 5 6 7 R Bend Radius 80 100 125 150 175 R Bend Radius 80 100 125 150 175 A Min. 9.4 10.4 11.4 12.4 13.41 A Min. 8.1 9.1 10.1 11.1 12.1 239 264 290 315 341 205 231 256 281 307 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 18 ✓ctaulic° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA c �L us Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers LISTED Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1733.7mm Sch.40 pipe inches inches feet mm Type DN meters Max Bends 31 1/2 790 15.0 3 Straight DN15 4 6 790 31 Straight1/2 4 DN15 4.9 31 790 3 Straight DN20 5.8 3/4 790 31 Straight DN20 6.10 4 915 3 Straight DN 15 5.5 36 1/2 915 Straight DN15 6.4 5 915 Straight 3/4 2DN20 6.4 3 36 915 Straight DN20 3/4 27.0 3.0 5 148 220 Straight DN15 6.4 3 48 1220 Straight DN15 9?8 8 3/4 148 220 Straight DN20 2.9 6.0 3 1220 48 Straight DN20 11.33 8 60 1525 Straight DN15 872 3 60 15225 Straight 10 DN15 14.060 1525 Straight DN20 872 3 60 15225 Straight 10 DN20 14.072 1830 Straight 3 DN15 9.472 1830 Straight1/2 12 DN15 16.872 1830 Straight DN20 9.10 3 72 1830 Straight DN20 18.3 12 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 19 ✓ctaulic° victaulic.com 5.0 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) c&us Series AH2 and AH2-CC Braided Hose with 90' Low Profile Elbows LISTED Style AB11 VicRex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1733.7mm Sch.40 pipe inches inches feet mm Type DN meters Max Bends 31 790 LP1/2 0 3 Elbow DN15 5.5 7910 LP Elbow 1/2 DN15 27.30 4 790 3/4 1 3 31 LP Elbow DN20 6.4 790 LP Elbow 3/4 DN20 27.30 4 915 LP Elbow DN15 5.836 3 915 LP Elbow DN15 1/2 27.9 6.0 5 915 LP Elbow 3/4 DN20 27.0 3.0 3 36 915 LP Elbow DN20 8 3/4 850 5 148 220 LP Elbow DN15 27.0 3.0 3 1220 48 LP Elbow1/2 8 DN15 13.1148 122 0 3 0 LP Elbow DN20 9.1 48 1220 LP Elbow DN20 12.860 8 1525 LP 0 3 Elbow DN15 8.5 60 1525 LP Elbow DN15 14.9 10 60 1525 LP Elbow DN20 9.4 3 60 15225 LP Elbow DN20 155.2 10 72 1830 LP Elbow DN15 9.472 3 LP1/2 12 Elbow DN15 19.8 1830 172 830 LP Elbow DN20 11.0 3 72 3/4 1830 LP Elbow DN20 19.22 3.0 12 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 20 ✓ctaul�c° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2751 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 '/2 11.0 13.0 15.0 16.0 790 DN15 3.4 4.0 4.6 4.9 31 3/4 12.0 14.0 19.0 20.0 790 DN20 3.7 4.3 5.8 1 6.1 36 '/2 14.0 16.0 18.0 19.0 21.0 915 DN15 4.3 4.9 5.5 5.8 6.4 36 3/4 17.0 19.0 21.0 22.0 23.0 915 DN20 5.2 5.8 6.4 6.7 7.0 48 '/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 1220 DN15 5.5 5.8 6.4 7.0 7.6 8.2 9.1 9.8 48 3/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 1220 DN20 6.4 7.3 1 7.9 8.5 9.4 10.1 10.7 11.3 60 '/2 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 1525 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 1525 DN20 7.0 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 72 1/2 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 1 7.9 1 8.5 1 9.1 1 10.1 1 11.3 12.2 13.4 14.6 15.5 16.5 17.4 18.3 NOTES • Values for use with 5.757140mm straight reducers. • The values in this table are provided by the manufacturer for reference only.For friction loss data in accordance with the UL Certification,please refer to pages 19 and 20 of this publication. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 21 ✓ctaulic° victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, ABS, AB7, AB7 Adj., ABB, AB1O, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90'Bends Stainless Steel Outlet 1733.7mm at 77178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/z 13.8 15 4.2 31 5.6 Straight 790 8.1 1/22 15 23.5 90°Elbow 7.1 1/z 15 16.6 36 5.6 Straight 5.1 2 915 8.1 1/2 25.6 15 90°Elbow 7.8 1h2 23.4 15 71 48 5.6 Straight 1220 8.1 1/23 15 30.7 90'Elbow 9'3 1/z 15 30.2 60 5.6 Straight 9.2 4 1525 8.1 1/2 35.9 15 10.9 90'Elbow 1/z 15 37.0 72 5.6 Straight 11.3 4 1830 8.1 1/2 41.1 15 12.5 90'Elbow 3/4 16.8 20 5.1 31 8.0 Straight 2 790 11.5 3/4 16.8 20 90'Elbow 5.1 3/4 20 20 6.0 36 8.0 Straight 2 915 11.5 3/4 19.7 20 90°Elbow 6.0 3/4 20 27.8 48 8.0 Straight 8.4 1220 11.5 3/4 3 20 26.6 90'Elbow 8.1 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90'bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 2400,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 22 ✓ctaulic° victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, ABS, AB7, AB7 Adj., ABB, AB1O, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 90'Bends Stainless Steel Outlet 1'733.7mm at 7/178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 20 35.7 60 8.0 Straight 10.9 4 1525 11.5 3/4 33.6 20 10.2 90°Elbow 3/4 20 43.5 72 8.0 Straight 13.2 4 1830 11.5 3/4 40.6 20 12.2 90°Elbow 3/4 16.5 20 5.0 31 11.2 Straight 2 790 16.1 3/4 17.8 20 90°Elbow 5.4 3/4 20 19.5 36 11.2 Straight 5.9 2 915 16.1 3/4 20.7 20 90°Elbow 6.3 3/4 20 26.7 48 11.2 Straight 8.1 3 1220 16.1 3/4 27.9 20 90°Elbow 8.5 3/4 20 33.9 60 11.2 Straight 10.3 4 1525 16.1 3/4 35 20 10.7 90°Elbow 3/4 20 41.3 72 11.2 Straight 12.5 4 1830 16.1 3/4 42.2 20 12.8 90°Elbow 3/4 20 14.9 31 14.0 Straight 4.5 2 790 20.2 3/4 15.5 20 4.72 90°Elbow FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30'bends and two 900 bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 23 ✓ctaulic° victaulic.com 5.1 PERFORMANCE — FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, ABS, AB7, AB7 Adj., ABB, AB1O, AB12, ABBA and ABMM WcFlex Brackets Maximum Equivalent Number Length of Length of of 90'Bends Stainless Steel Outlet 1733.7mm at T/178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 20 19.4 9 36 14.0 Straight 5' 2 915 20.2 3/4 19.6 20 90'Elbow 5.9 3/4 20 30.3 48 14.0 Straight 9'2 3 1220 20.2 3/4 29.5 20 90'Elbow 8.9 3/4 20 33.9 60 14.0 Straight 10.3 4 1525 20.2 3/4 34.1 20 10.4 90'Elbow 3/4 20 37.5 72 14.0 Straight 11.4 4 1830 20.2 3/4 38.6 20 11.7 90'Elbow FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90'bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 24 ✓ctaulic° victaulic.com 5.2 PERFORMANCE - FRICTION LOSS DATA FM Series AH2 Braided Hose with 90' Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 90'Bends Stainless Steel Outlet 1733.7mm at 7'7178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 1/2 13.7 2 790 8.1 15 4.2 36 5.6 1/2 17.0 2 915 8.1 15 5.2 48 5.6 1h 25.0 3 1220 8.1 15 7.6 60 5.6 1/2 33.0 4 1525 8.1 15 10.1 72 5.6 1h 41.1 4 1830 8.1 15 12.5 31 8.0 3/4 13.6 2 790 11.5 20 4.14 36 8.0 3/4 16.9 2 915 11.5 20 5.2 48 8.0 3/4 27.8 3 1220 11.5 20 8.5 60 8.0 3/4 32.6 4 1525 11.5 20 9.9 72 8.0 3/4 40.6 4 1830 11.5 20 12.4 31 11.2 3/4 13.7 2 790 16.1 20 4.2 36 11.2 3/4 17.0 2 915 16.1 20 5.2 48 11.2 3/4 24.9 3 1220 16.1 20 7.6 60 11.2 3/4 32.9 4 1525 16.1 20 10.0 72 11.2 3/4 40.9 4 1830 16.1 20 12.5 31 14.0 3/4 13.5 2 790 20.2 20 4.1 36 14.0 3/4 16.8 2 915 20.2 20 5.1 48 14.0 3/4 24.7 3 1220 20.2 20 7.5 60 14.0 3/4 32.7 4 1525 20.2 20 9.9 72 14.0 3/4 40.7 4 1830 20.2 20 12.4 FM NOTES • The Series AH2 hose has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 standard for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characteristics,vibration resistance, leakage,mechanical and hydrostatic strength. • EXAMPLE:A 48-inch hose installed with two 30'bends and two 90'bends is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 25 ✓ctaulic° victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA VdS Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 DIN 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90'Bends at mm DIN meters 3776.2 mm Bend inches inches feet Radius DN15 790 '/2 5.5 3 31 DN20 18.0 3/4 DN15 915 1/2 6.4 3 36 DN20 21.0 3/4 DN15 1220 1/2 8.5 3 48 DN20 27.9 3/4 DN15 1525 1/2 10.7 4 60 DN20 35.1 3/4 DN15 1830 1/2 12.8 4 72 DN20 42.0 3/4 VdS Ceiling Manufacturers List AB2,AB7,AB10,AB11 AB4 AB5,AB8 1.AMF No specific approval 1.Hilti 2.Armstrong 2.Knauf 3.Chicago Metallic 3.Lafarge 4.Dipling 4.Lindner 5.Durlum 5.Rigips 6.Geipel 7.Gema-Armstrong 8.Hilti 9.Knauf 10.Lafarge 11.Linder 12.Odenwald 13.Richter 14.Rigips 15.Rockfon Pagos 16.Suckow&Fischer 17.USG Donn 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 26 ✓ctaul�c° victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA OLPCBSeries AH2 and AH2-CC Braided Hose Series AH2 Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, Style AB2, AB3, AB4, AB5, AB7, AB8, AB1O aR and AB1O Brackets and AB12 Brackets Length of Tquivalent Length Maximum Stainless of steel pipe Number of Equivalent Length of Steel according to 90°Bends at Length of 1'733.7 mm Sch.40 Pipe Flexible Outlet EN 10255 DN 25 3'176.2 mm Flexible Hose Size (33,7 x 3,25) Bend Radius Hose Straight Configuration Bend Configuration mm mm inches meters mm meters meters inches type feet inches feet feet 15 mm 1/2 790 Straight _ 1.8 2 790 0.87 2.70 31 20mm 6.0 31 2.9 8.9 3/4 Straight 15mm 1/2 915 Straight 3.6 3 915 1.00 2.80 36 20mm 11.9 36 3.3 9.2 3/4 Straight 15mm 1/2 1220 Straight 4.3 1220 2.23 4.66 48 20mm 14.0 3 48 7.3 15.3 3/4 Straight 15mm 1/2 1525 Straight 4.1 3 1525 2.90 6.5 60 20mm 13.6 60 9.5 21.3 3/4 Straight 15mm 1/2 1830 Straight 5.5 3 1830 3.31 7.16 72 20mm 18.1 72 10.9 23.5 3/4 Straight 111111 CCCF NOTE • Friction loss data is in accordance with G135135.16 tested at a flow rate of 114 liters per minute(30 gallons per minute). 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 27 ✓ctaulic° victaulic.com 6.0 NOTIFICATIONS A WARNING • Read and understand all instructions before attempting to install Y� any Victaulic products. ), • Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. A WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. • It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 28 '✓ctaulic® victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m Ib N Ib/linearft N/linearm 31/790 6 5. 23 2.6 38 0.8 36/915 �9 5.5 25 2.8 40 48/1220 1 2 6.3 28 3.1 46 60/1525 1 5 7.0 31 3.5 51 72/1830 1 8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 36/915 0 9 6.4 29 1.6 23 48/1220 1 2 7.2 32 1.8 26 60/1525 15 7.9 35 2.0 29 72/1830 1 8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min.Allowable Uniform Load Suspension System ft/m Ib/linearft N/linearm Light 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 29 ✓ctaulic° victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends %dus 2X nimum 90. Minimum d radius bend radius \ OR Minimum I OR bend radius I __ Minimum bend radius Minimum ------------ — — Minimum ( bend radius bend radius 'I Minimum bend radius -- Minimum 1 bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. -VicFlex-AB1-AB2 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM I-RES User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10,I-VICFLEX-AB4, or waive any provision of Victaulic Company's standard conditions of sale,installation I-VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.85 5839 Rev AL Updated 02/2022 ©2022 Victaulic Company.All rights reserved. victaulic.com 30 ✓ctauliilce BULL MOOSE® EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET TUBE APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based • ASTM A795,Type E, Grade A paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate,the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain • NFPA-14 minimal bacterial count after multiple flushes (25) of the pipe. • CIVIL DEFENSE APPROVAL— • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC&FM listed for roll-groove, plain-end and welded joints for wet, dry, Every length of BUII Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer,type • LEED v4 Certified of pipe,size,and length. mom 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4,310 7 JEMPtVWe'11gJnT(10F1.222 1.844 2.330 2.809 3.361 4,968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7,144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY U1 C U1 FM L SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments O Eddy Flow-Black Eddy Flow-Hot Dip Galvanized BULLT/[OOSETUBE. - 00 00 Schedule • and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal .- Size (in) Nominal O.D. 1 1.315 1.097 1.41 Ibs/ft 91 1 1/4 1.660 1.442 1.81 Ibs/ft 61 1 1/2 1.900 1.682 2.09 Ibs/ft 61 2 2.375 2.157 2.64 Ibs/ft 37 2 1/2 2.875 2.635 3.53 Ibs/ft 30 3 3.500 3.260 4.34 Ibs/ft 19 4 4.500 4.260 5.62 Ibs/ft 19 Schedule 40 Pipe 116� Nominal Pipe Size (in) Nominal O.D. (in) 1 1.315 1.049 1.68 Ibs/ft 70 1 1/4 1.660 1.380 2.27 Ibs/ft 51 1 1/2 1.900 1.610 2.72 Ibs/ft 44 2 2.375 2.067 3.66 Ibs/ft 30 2 1/2 2.875 2.468 5.80 Ibs/ft 30 3 3.500 3.068 7.58 Ibs/ft 19 4 4.500 4.026 10.80 Ibs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. QiIZ 1819 Clarkson Road Foradditonal inforpmation, C �L usA Chesterfield, MO 63017 contact our salesperson (800)325-4467 today at(800)325-4467 or LISTED BULL MOOSE TUBE COMPANY FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada F M A UP- company e-mail: sales(c�bullmoosetube.com call(800)882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 t t tllll &64mmys 20184019 � + Product Catalog Ap TABLE OF CONTENTS Sammys°for Wood .......................................................................................................................... 4 Sidewinder"for Wood....................................................................................................................... 5 Sammys Swivel Head" for Wood......................................................................................................5 Sammys°for Steel............................................................................................................................ 6 Sidewinder"for Steel........................................................................................................................ 7 Sammys Swivel Head'm for Steel....................................................................................................... 7 SammyX-PressO............................................................................................................................... 8 SammyX-Press SidewinderTM............................................................................................................ 8 SammyX-Press Swivel'm................................................................................................................... 9 Sammy X-Press It° Installation Tool .................................................................................................. 9 Sammys°for Concrete................................................................................................................... 10 Sidewinder"for Concrete ................................................................................................................ 10 Sammys Swivel HeadT11 for Concrete................................................................................................11 Concrete/Wood Installation Kit........................................................................................................ 11 SammysToggleTM............................................................................................................................ 12 Dektite° Pipe Flashing..................................................................................................................... 12 Sammys X-Press° Pole Tool Kit...................................................................................................... 13 SammysPole ToolTM......................................................................................................................... 13 Approvalsand Listings.................................................................................................................... 14 SpecialNotes .................................................................................................................................. 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used.Allowance for special characteristics in materials,differences in materials,differences in types of materials being joined,unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered.Due to possible differences in specifications,applications,and interpretation of results,purchasers and specifiers must make their own evaluation of the products,to determine the suitability of these products for intended use.All warranties of Buildex products,expressed or implied,including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following:Buildex will repair or replace any product which,within twelve months after sale by Buildex or its distributors,is found by Buildex to be defective in material or workmanship-normal wear and tear accepted.This is the sole warranty of Buildex and the sole remedy available to distributor or buyer.Buildex shall not be liable for any injury,loss or damage,direct,indirect,or consequential,arising out of the use of,or the inability to use,any Buildex product. INSTALLATION • • ' WOOD & STEEL INSTALLATION STEP INTO WOOD&STEEL: INSTALLATION STEP •' •MTO WOOD&STEEL: 1.Insert the appropriate nut driver into a 318"or 1/2°portable drill. 1.Insert the appropriate nut driver into a 318"or 112"portable drill. 2.Insert the SAMMYS®into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.Begin installation when the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins freely on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114"318",112"or metric all thread rod,bolt stock.(The 112"requires the#14SW red nut driver) 4.The unit is now ready to receive 114",318",M10,M8 or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximumpullout in purlin steel. Note:When installing SWDR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximum pullout in purlin steel. INSTALLATION • FOR CONCRETE INSTALLATION STEPS- =INTO CONCRETE: INSTALLATION STEPS = INTO CONCRETE: 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit,pre-drill the concrete member to a depth of 2"with a carbide tip bit,pre-drill the concrete member to a depth of 2"with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2.After pre-drilling has been completed,install the SLEEVE TOOL over 2.After pre-drilling has been completed,install the SLEEVE TOOL the bit(the bit should remain in the drill),and insert the#14(black) over the bit(the bit should remain in the drill),and insert the#14SW(red) nut driver(p/n 8113910)into the opposite end(see Vertical Installation nut driver(p/n 8114910)into the opposite end. note above). 3.Insert the SWC screw into the nut driver. 3.Insert the CST screw into the nut driver. 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill drill mode and begin insertion.When the nut driver spins free on the mode and begin insertion.When the nut driver spins freely on the SWC screw,installation is complete.Stop and remove drill. CST screw,installation is complete.Stop and remove drill. 5.The SWC screw is ready to receive 114"318"or metric all thread rod 5.The concrete screw is ready to receive 114",318°112",or metric all or bolt stock. thread rod or bolt stock.(#14SW red nut driver used with 112"screw) Note:Use a 1200 maximum RPM drill for installation. Note:Use a 1200 maximum RPM drill for installation. Note:Do not install concrete screws while the drill unit is in impact mode— Note:Do not install concrete screws while the drill unit is in impact mode— doing so will destroy the pullout factor of the fastener doing so will destroy the pullout factor of the screw. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 3 To find a distdbutor near you,call 800-848-5611 SAMMYS° FOR WOOD SAMMYS' FOR WOOD - Vertical Application Application Product Features Not less than Wood Flooring 2"nominal width •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill. (2-1/2") (depth or side Wood Joist'thickness f vertical member) _ •Saves time from traditional methods. Double Sheetrock Ceiling •Reduces installation costs. Assembled in the U.S.A. Composite Truss Consult truss manufacturer for recommended installation point. *Pre-dtilfing may be required for GST :r View our installation videos! 0YOUTUbe Rod Part Model Screw Ultimate UL Test FM Test Box Case Approvals Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Gty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 L 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) O 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 #14 Black 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 Nut Driver v 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Part#8113910 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 w � rr AIf SSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 SIDEWINDER@ FOR WOOD -Horizontal ApplicationApplication o Product„ 5 Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5'pipe •Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. •Assembled in the U.S.A. :r View our installation videos! O YOUTUk HORIZONTALApprovals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Shear(Ibs) Load(Ibs) Gty QtY . VIL 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 Q. 3/8" 8022925 SWG 25-380 318 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL HEAD Tm FOR WOOD Swivel Application Application Product Features r..•an c.*00°.,,,.10", •Eliminates distortion of threaded rod. ", •Accommodates up to 3'%"x 12 pitch roof. •Allows 17°deflection from vertical. ..a •Saves time from traditional methods. •Reduces installation costs. �rre� •*. Assembled in the U.S.A.Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case • Size Number .• City e #14 Black SWIVEL MOUNT Nut Driver 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#81139101 1903 Dim.Lumber 1500 33/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 May require pre-drilling;consult joist manufacturer. Dim.Lumber #14 SH Orange ••will not swivel until installed with black nut driver. • Nut Driver Part#8273910 To find.distributor near y• 800-848-5611 SAMMYS® FOR STEEL SAMMYS' FOR STEEL - Vertical Application Application Product Features •Made with Teks®self-drilling fasteners- no pre-drilling required. •Installs into steel range from ` 20 gauge—1/2"thicknesses. �' •Saves time from traditional methods. •Reduces installation costs. •Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. •A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance,the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. ,► •Assembled in the U.S.A. P�►�.O�►JL� � View our installation videos! MuTube Approvals Rod Part Model Screw Ultimate ILL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x V TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4'. 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 _ 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 0 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-112"TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 �} 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 i 0 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) #14 Black 3/8" 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 Nut Driver Y 0 3/8" 8046957 TEK 50 12-24 x 1-112"TEKS 5 3125 (3/16") 1500 1475 .250"-l/4" 1/2" 25 125 Part#8113910 446 (20 ga.) .::--•� 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 g70 (16 ga.) .188"-3/16" 1/4" 25 125 .. 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 s � oHS 00"I ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. ProductSIDEWINDERI FOR STEEL -Horizontal Application Application •Made with Teks°self-drilling fasteners-no pre-drilling required. NO •Installs into steel range from 20 gauge—1/2"thicknesses. }�� •A standard screwgun with a depth sensitive nosepiece should be used to install Teks.For optimal fastener performance,the screwgun should be a -- minimum of 6 amps and have an RPM range of 0-2500. Y0 •Saves time from traditional methods. J •Reduces installation costs. W •Quick to install using the Sammys Nut Driver with an View our W 18V cordless drill/driver. installation videos! •Asembled in the U.S.A. 0 YothbeApprovals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case y Size Number D- Qty Qty HORIZONTAL MOUNT 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 v 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8054957 SWDR 1-1/2* 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 3/8" 8056957 SWDR 516* 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL .Tm • - STEEL Application Application Product Features •Eliminates distortion of threaded rod in sloped roof applications. r •Accommodates 3-1/2 x 12 pitch. • •Installs into angled z-purlin;allows threaded rod to hang plumb. •Allows 17°deflection from vertical. •Asembled in the U.S.A. 1 View our installation videos! CYoubbe Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case Size Number •. Qty Qty SWIVEL MOUNT M #14Black " 81379 11TEK S 3 X 1" ( ) Nut 3/8 57 SH-DSTR 1* Driver TEK 3220 3/16" 1500 1475 .035" 3/16" 25 125 Nut Part#8113910 2368(1/2"steel Vertical) 3/8" 8268957 SH-TEK 50 12-24 x 1-5/8" 1306(45°off Vertical) 1500(Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281(3/16"HISS) 850(45°off Vertical) 2-1/2" 1585(3/16"HISS 45°off Vertical) *Does not comply with ROHS requirements/Includes retaining nut #14 SH Orange • Nut Driver Part#8273910 SA MMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel SAMMYX-PRESSOApplication ProductApplication •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin •No retaining nut required. � (22 ga.-1/8"). •Provides design flexibility. •Installs in seconds with Sammy X-Press It®Tool, saving time&installation costs. •Assembledin the U.S.A. •Use in applications where access to the back of View our the installed fastener is prohibited.is.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. Woubbe DescriptionApprovals Rod Part Model Size Number Pullout(lbs) Load(lbs) Thick Load(lbs) Thick Thick • QtY MOUNTVERTICAL Sammy 185(Luminaire) .027 NL 1/4" 8181922 XP 200 X-P ess 200 1146(22 ga) 250(Luminaire) .056" .125" 25 125 Metal Deck ■ 850(2%"Pipe) .027" 940 (2"Pipe) 029" X-Press 20 250 3/8" 8150922 XP 20 Sammy 1146(22 ga) 250(Luminaire)(Luminaire) .0.056"" 1475(4"Pipe) .104" .125" 25 125 Metal Deck 283(Conduit&Cable) .029" 1500(4"Pipe) .060" 3/8" 8153922 XP 35 X Pr ss 35 1783(16 ga) 250(Luminaire) .056" 4775((4"PI pe) .1104" .125" 25 125 Purlin 416(Conduit&Cable) .059" T Pre-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2%Pipe) 25 125 (Pre-Pour) X-Press 20 Post-Pour Range II LWC<_35 PCF(lbs/ft3) Metal Deck (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibs/ft') —J—�VVE Lr -�- Lr'� SAMMYX-PRESS SIDEWINDER'" - Horizontal Application Application Product •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. provide horizontal attachment in: 16 ga-3/16"steel-purlin,tubular steel. •No retaining nut required. •Installs in seconds with Sammy X-Press It®Tool, •Provides design flexibility. saving time&installation costs. •Assembled in U.S.A.of •Use in applications where access to the back of Canadian Steel the installed fastener is prohibited;ie.metal roof View our deck,tubular steel,or vapor barrier fabric. installation videos! 0 Youbbe DescriptionApprovals Rod Part Model Size NumberShear(Ibs) Load(lbs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT 1250(3%'Pipe) 3/8" 8293957 SWXP 35 Sidewinder 1798(16 ga) 80 (Luminaire) .059" .125" 25 125 Metal rlin in X-Press 35 416(Conduit&Cable) Pu � S ASSEMBLER U.S A. TM SAMMYX-PRESSA . . ProductApplication •The Sammy X-Press Swivel allows you •Less jobsite material needed. to hang plumb in extreme roof pitches: 89*in z-purlin •No retaining nut required. 45'in metal deck for 12/12 pitch � •Provides design flexibility. EREM •Installs in seconds with Sammy X-Press It®Tool, f)10' n 1 G saving time&installation costs. •Assembled in the U.S.A. V�p1�NT •Use in applications where access to the back of View our the installed fastener is prohibited.ie.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. MOW— O — DescriptionApprovals Rod Part Model Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty MOUNTSWIVEL 750(2"Pipe) Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) Metal Deck/ 3/8" 8294922 SXP 20 80 @ 45°(Luminaire) .029" 635(2"Pipe) .029" .125" 25 125 X-Press 20 829(45°Off Vert) 283 Vertical(Conduit&Cable) Pudin 11J 233 @ 45°(Conduit&Cable) 'W 1250(3-1/2"Pipe) 250 Vertical(Luminaire) ? 3/8" 8295922 SXP 35 Swivel 1675(16 ga Vert) 80 @ 90°(Luminaire) '059° '029" .125" 25 125(Luminaire) Metal Deck/ X-Press 35 1558(89°Off Vert) 500 Vertical(Conduit&Cable) 635(2"Pipe) Purlin 333 @ 89°(Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vert) Pudin 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) Metal Deck/ X-Press 3.5 1558(89°Off Vert) .060" .125" 25 125 Pudin • SAMMYX- - - © • • • Application Product ` •The Sammy X-Press expands to provide direct vertical attachment in: metal deck(22-16 gauge) y4 J t z-purlin(18-16 gauge) •Assembled in the U.S.A. View our installation videos! 0 Youbbe DescriptionPart Number Model 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64"Drill Bit 1 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. 1 1 • To find-distributor near y• 800-848-5611 SAMMYS° FOR CONCRETE SAMMYS@ FOR CONCRETE — Vertical Application Application Product Features •Easy two step process(Drill hole& *•4��'4 ,d o d v; �•4,'Q drive Sammys concrete anchor). ?" 'a r 4?" a •1W pre-drilled pilot hole required. . 7 ` .D `ad•`aJ�A�• :d `pd• •� •Concrete Installation Tool available for CC a one tool installation process. •Assembled in the U.S.A. -j .f••'ft••r ••r•' � j•• fir View our ... installation videos! 0YOUTUbe Size Number Descriptions Pullout(lbs)* Load(lbs)Approvals Rod Part Model Screw Ultimate I'M Test Box Case VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part#8113910 — #14SW Red 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 36-EFM 3/8" 8306957 CCST 516 5116-14 x 2-1/2" 857** 25 125 Part#8114910 For complete performance data see ICC Report ESR-3699 Tested in 3000 PSI concrete **Pullout strength for Cracked Concrete and Seismic Zones A-F ProductSIDEWINDEW FOR CONCRETE - Horizontal Application Application �' •Easy two step process(Drill hole&drive •4• U°• Sammys concrete anchor). � I I • C p '�' o'P Z •'/<"pre-drilled pilot hole required. •Concrete Installation Tool available for a one tool D., -p. • C installation process. d ri ol77`4; , a o � •Assembleded in the U.S.A. View our installation videos! OYNTUM Approvals Rod Part Model Screw Ultimate FM Test Box Case Size Number 1• Qty Qty HORIZONTAL MOUNT 0 3/8" 8061957 SWC 20 5/16 x 1-3/4" 2450 1475 25 125 O 369gEFM 3/8" 8307957 SW-CCST 516 5/16-14 x 2-1/2" 857** 25 125 #14SW Red Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Nut Driver Part#8114910 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.ASSEMBLED U.S.A. �S free.Installation n t onis then complete.rWarranty requires thecuse ltof the appropriate nut driver for installations.continue drilling until nut driver spins OZZHH'yo SAMMYS SWIVEL HEAD Tm FOR CONCRETE Swivel Application Application Product Features •Installs vertically and swivels up to 89°in wood& concrete structures. •:moo s..�:=.P' Eliminates distortion of threaded rod. •1/4"pre-drilled pilot hole required. •Concrete installation tool available for a one piece installation process. •Assembled in the U.S.A. Approvals Rod Part Model Screw Ultimate Box Case Size Number .• Qty Qty SWIVEL MOUNT 2537 in 3000 psi concrete 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1459 @ 45°off vertical in 3000 psi concrete 25 125 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete FM 3/8" 8308957 SH-CCST 516 5/16-14 x 2-1/2" 857** 25 125 Note:UL Listed for wood-see page 5 #14 SH Orange Nut Driver Part#8273910 *Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Uj CONCRETE I WOOD INSTALLATIONLLI Ct V Application Z 'CRotary Hammer Drill into concrete Hammer Drill into concrete (b) b (9) (d) (h) (gam (e) (h) -sepiao, (C) (c) (a) Part Number Description Each Qty • 8122910 Concrete Installation Kit(a) 1 Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 8114910 #14 SW Red Nut Driver(c) 1 8116910c #250 Bit(1/4")(d) 1 8117910 SIDS Bit(1/4")(e) 1 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 8098910 SL 250 Sleeve(h) 1 To find a distributor near you,call 800-848-5611 ACCESSORIES SAMMYS TOGGLE TM Application Installation Steps 1.Pre-drill a 5/8"hole with a regular drill or hole saw. 4N, 2.Insert SST screw into#14 black nut driver.With wing nut and washer on bolt,insert wing nut through surface,and begin J installation. 3.When bolt is secure and nut driver spins free,stop drill motor and remove. Pre-Cast Hollow Core 4.SST screw is now ready to receive 114",3/8",or Metric all Concrete thread rod or bolt stock. o. r D• e ty 'Size Part Number Model • 450 (Lath&Plaster)' 3/8" 8064925 SST 30 1/4 x 3" 404 (2 Layers 5/8 Rock) 25 125 #14 Black Nut Driver Part#8113910 PIPE Application ,r •Complies with NFPA 13 Code Changes. •Flashing for dry pendant sprinklers subject to 4-f�RTITE 51 AY �p TO extreme temperature changes. CODE s •One piece construction is easy to install. --- with a qui<har, •Pipe diameter markings ensure accurate fit. U ARM more efficient war HOLE to fl4sh your •EPDM temperature range of-65OF to+250°F. refri9crationifreaicy units. tresrtUlTEo FREEZER STRUCTURE t—Nn fif>fU�118 Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4003910 1 1/4"-2" 4-3/4" 3" 10 4004910 2 1-3/4"-3-1/4" 6-1/4" 4" 10 . 1. - 1 11. 611 11. oil SAMMYX-PRESS POLE TOOL • Application Product Features Speed your labor by 25% Work from the ground up It �w No scaffolding,ladders,or lifts v Perfect for working in tight spaces,through ceiling grid, --— and high vaulted ceilings For use installing Works with any Sammy X-Press product t Sammy X-Press anchors from the ground up! View our installation videos! p YouTube r Part Number Model Description Box Qty 1 XPKIT* XPKIT Sammy X-Press Pole Tool Kit 1 3/4"electdcal conduit needed for pole tool assembly • ji• SAMMYS �. POLE TOOL TIM Installation , Product Speed your labor by 25% 1 2 3 Insert •Work from the ground up adjust! here No scaffolding,ladders,or lifts Perfect for working in tight spaces,through ceiling grid, Adjust the Pole Tool to length. Load rod and Sammys into The socket will spin free and high vaulted ceilings The adjusting pin must be 18" Pole Tool. when the screw is completely below the base or the pin may installed.Pull down to remove •Works with any Vertical SAMMYS:Wood,Steel,or interfere with the rod. the Pole Tool. Concrete • Part Number Description Box Qty Pole 6'-18' 1 W W O 0 W V V Q • APPROVALS Part Numberr . ..• Mount UL Max ULTest UIL Min Wood FM Max FM Test FM Min Wood _ 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2' 8068925 GST20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-112' 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG25-380 3/8" Horizontal 3-1/2"-4"* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3"** 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45"Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1475 1-1/2" SAMMYS FOR STEEL-PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 318" 17'Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK50 3/8" Vertical 2-1/2" 850 70*Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89' 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE-PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC<_35 PCF(lbs/fC) Part Model .. Mount UL Load UL Min Steel SAMMYS Number Size Direction Rating(Ibs) Thickness 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 318" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8' Vertical 170 .027" 45' 80 .027" 8295922 SXP 35 3/8' Vertical 250 .060" 90* 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" Part Model Rod Mount UL Load UL Min.Steel Listed Application Number Size Direction Rating(Ibs) Thickness SAMMYS FOR CONDUIT, 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 1/4"or 3/8" Onto Vertical Rod UL Listed 4S16-Cable Hanger,Cat.No.C-Z2000 Plenum Rated, Complies w/NEC Standards GaugesSheet Steel Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber orjoist allowed by UL is 4" UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum pipe size in wood timber or'oisl allowed to UL is 3" SPECIAL NOTES • Engineering Note • In 1996,the anchors listed by UL were tested in plate steel that measured.188"and.118".Subsequent testing was done for z-purlin applications in May 1997 using(.037")or 20 gauge steel.Most recently in 2008,testing with the new Sammy X-Press®was completed using(.030")or 22 gauge steel metal deck. Sammys®Nut Drivers Special nut drivers were designed to be used with Sammys.When the appropriate nut drivers are used for installation,the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure. Steel Screws Due to variations in hardness of certain metals,it should be noted that our self-drilling screws for steel will experience different drill speeds.500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist.UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a composite joist.Penetration of the upright center web is permitted by some joist manufacturers.Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot hole 1/8"smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7132" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers,and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards.Check with your local(AHJ)Authority Having Jurisdiction to confirm application and usage. UL Listings/FM Approvals UL and FM reports are available at www.itwbuildex.com �uLD 5 O • 111B RAKER ALSO LISTED AS CONDUIT AN O CABLE HARD WARE ALSO USMB AS ANCHOR FOR LUMINAIRE B., Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats:.dwg,.dxf,and.igs. Assembled in the U.S.A. Products Contact Information As—bledUSA Technical Assistance:(800)848-5611 Option#6(x 3259) Customer Service:(800)848-5611 Option#1 • J Q Q. Q. Q 15 To find a distributor near you,call 800-848-5611 115 Standard Duty - i The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines,including CPVC pipes, in fire sprinkler systems.A knurled insert nut helps simplify vertical adjustments and flared edges on the base(1/2"to 4"sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe(1/2"to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non-insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA°for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society(MSS)SP-58(Type 10) �- -RS C 8 A OD �F Material:Steel FM Finish: Pregalvanized C UL US wv►•oveo Outer Diameter Rod Size Static Load Part Number Pipe Size OD RS A f3 C F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 3001b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 1b cULus,FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16'* 3001b cULus,FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 1b cULus,FM 1150150EG 1 1/2" 1.900" 3/8" 3 13/16" 1 5/8" 15/16" 300 lb cULus,FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 lb cULus,FM 1150250EG 2 1/2" 2.875" 3/8" 5 15/16" 3 7/16" 2" 5251b cULus,FM 115030DEG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 lb cULus,FM 1150350EG 3 1/2" 4.000" 3/8" 7 1/16" 3 3/4" 1 15/16" 585 lb cULus,FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 lb cULus,FM 1150500EG 5" 5.563" 1/2" 9 13/16" 4 3/4" 2 1/4" 1,000[b cULus,FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 lb cULus.FM 1150800EG 8" 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus,FM nJent CADDY FM is a registered certification mark of FM Approvals LLC,LTD.NFPA is a registered trademark of National Fire Protection Association,Inc.UL,UR,cUL,cUR,cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials,Instruction sheets are available at www.erico.com and from your nVent customer service representative.Improper installation,misuse,misapplication or other failure to completely follow nVent'a instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ®2019 nVent All rights reserved nVent,nVent CADDY,nVent ERICO,nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners.nVent reserves the right to change specifications without prior notice. v, mkiri CADDY FireLock EZ° Rigid Coupling C&f FM yds ilu4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining.The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Nominal Size 11/a 175 365 365 365 365 32 1206 2517 2517 2517 2517 11h 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 21h N/A 365 365 365 365 65 2517 2517 2517 2517 76.1mm N/A N/A 365** 365 365 2517** 2517 2517 3 N/A 365 365 365 365 80 2517 2517 2517 2517 4 365 365 365 365 100 N/A 2517 2517 2517 2517 165.1mm N/A N/A 290** 232 300 1999** 1600 2068 6# N/A 290 365 232 365 150# 1999 2517 1600 2517 rt Listed/Approved for wet and dry pipe systems(>—40°F/-400C). Please refer to the Victaulic Installation Manual(1-009H_009_009V.pdf)for details concerning when supplemental lubrication is required. *` EN-10219(L)for 76.1mm size;EN-10255(M)for 165.1mm size # Regional availability only Speciality Pipe Pipe Size psi/ a Pipe Size psi/ Pipe Size /kPa BLT 1 Ya—2 300 300 EZT 1/a—2 300 300 MT 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 DF 1 Ya—4 300 300 FF 1 Ya—4 300 300 MLT 1 Ya—2 N/A 300 2068 2068 2068 2068 2068 DT 1 Ya—2 300 300 FLF 1 Ya—4 N/A 300 ST 1'/a—2 N/A 300 2068 2068 2068 2068 EF 1 Ya—4 175 175 FLT 1 Ya—2 N/A 300 STF 1'/a—4 N/A 300 1206 1206 2068 2068 EL 1 Ya—2 300 300 FLTL 1 Ya—2 N/A 300 TF 2Ya—4 N/A 300 2068 2068 1 2068 1 1 2068 ET40 1'/a—2 300 300 GL 1 Ya—2 300 300 WLS 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 EZF 3-4 300 300 MF 1'/a-4 300 300 WST 1'/a-2 N/A 175 2068 2068 2068 2068 1206 XL 1'/a—2 300 300 2068 2068 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC_tau I1C REV_F 10.61_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.61 FireLook EZ° Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS No.-Size Dimensions-Inches/mm L�a e m b I ed ss St R1.660365 condition) Joint Assembled M Inches X 1 Ya 790 0.10 1 2 -3/8 x 2 1 2.95 1 4.77 2.70 1 4.63 1.93 1.4 32 42.4 2517 1 3514 2.54 -M10 x 2 75 121 69 1 118 49 1 0.7 1'/2 1.900 365 1035 0.10 2 -3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 -M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.375 365 1616 0.12 2 -3/8x2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 -M10 x 2 96 140 88 138 49 0.9 2'/2 2.875 365 2370 0.12 2 -3/8 x 2'/2 4.29 6.09 3.92 5.85 1.93 2.1 Y E L 65 73.0 2517 10542 3.05 M10 x 2'/2 109 155 100 149 49 1.0 76.1 mm 3.000 365 2580 0.12 2 -1/8 x 2 1/24.40 6.31 4.05 5.90 1.93 2.1 76.1 2517 11476 3.05 M10 x 2'/2 112 160 103 150 49 1.0 X 3 3.500 365 3512 0.12 2 -3/8 x 2'/2 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 M10 x 2'/2 125 170 116 164 49 1.0 _ 4 4.560 365 5805 0.17 2 -3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 M10 x 2'h 151 199 141 190 55 1.3 STYLE 009H JOINT ASSEMBLED 165.1 mm 6.500 290 9623 0.17 2 -1A x 3 Ya 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 M16 x 3 Ya 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 1 2 -1A x 3 1/47.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 -M16 x 3 Ya 1 202 281 195 305 54 2.69 Working Pressure and End Load are total,from all internal and external loads,based on standard weight (ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown in the chart on page 1,specific to pipe schedule and size. t The allowable pipe separation dimension shown is for system layout purposes only.Fire Lock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel(North America,Asia Pacific) • Red enamel(Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade"E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.9UI1C® 10.61_2 REV_F FFireLock EZ° Rigid Coupling STYLE 009H GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps con- taining the"QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling.There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade "E"Type A gaskets.These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop,that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.61 5731 REV F UPDATED 10/2011 �CtaLlIiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.61 FireLock° Fittings <&> @ LPCB See Victaulic publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-l. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC._tau IiC REV_I 10.03_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings DIMENSIONS �-CtoE� toE� I u CtoE WC - o o , •� TEto E oo tE �<e NO.001 NO.003 NO.002 NO.006 Size ,. 'Elbow 45'Elbow Straight Tee Cap Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness"T" Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs 1 Y4 1.660 0.8 0.3 32 42.4 21 1 0.1 1'/2 1.900 - - - - - 0.82 0.4 40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 L2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 1 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id 10.03_2 REV_I IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings FLOW DATA Size Equivalent Feet/meters of Straight Pipe t Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches �� �0 0.Elbow Elbow Branch Run 1'/4 I 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 Yz 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2'/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id REV-1 10.03_3 A . r�FireLockO Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009WO09H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV I UPDATED 2/2010 �CtaLJIIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 Mechanical-T° Bolted Branch Outlets SEE FM �c Vd3 LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 115 top housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30OF to+230°F/-340C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+820C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iIIIIC 1I1C® REV_O 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Appr x. Size Dimensions Weight Each minal Size D. Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs. L, F Y �Z� �� - - 2 x 1/2(a)d 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4(a)❑ 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a)n 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 w 25 3450 38.1 47 64 41 136 70 1.4 1 Y4(a)to g20N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 C5- I? 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y �Z� 65 x Yz(a)§d 920N 500 L50 2.21 2.74 _ 1.82 143 2.0 1 A 65 a) 3450 1.5 .1 70 46 1.6 70 1.4 3/a(a)§d 920N 500 i 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 _ LF 20 3450 38.1 55 70 46 143 70 1A T 1(a)§n 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 25 920N 3450 38.1 52 70 46 143 70 1.4 1'/4 t(a)0 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 1 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1�/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 Yz(a)a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 /2(a)0 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6--r • Sizes from 2 x 1/2'/50 x 15 mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)o 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3/2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/2"BSPT clearly on order. §Vds approved for fire protection services o-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St'le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. 'tl e Ma rk 920 or E Y �Z m m 920N -0.00 TABLE CONTINUED FROM PAGE 2 - 4 1/2(a)❑ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 r I 3/4(a)❑ 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 w 1(a)a 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 _ 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y4(a)tM 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 1/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2(a)to 920N 4 0 63.5 83 102 100 68 17 99 2.3 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 w 3450 69.9 73 102 68 186 118 2.9 1? 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)o 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)o 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 - 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 1 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use rig(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1/2750 x 15 mm 3450 699 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 _ 80 920 3450 88.9 97 1 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com iiiCtaILJIiiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions minal Size, Inches +0.13 Inches Inches Inches Inches Inches Inch'7h or es D. es y �Z� 0r mm mm mm mm mm m TABLE CONTINUED FROM PAGE 3 - 1 Yz t 500 2.00 3.78 4.50 3.30 8.23 3.25 1 7.0 i 139.7 x 40 920N 3450 50.8 96 114 - 84 209 83 3.2 - T 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- 50 3450 63.5 95 114 84 209 99 4.1 w 6 1 Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'/z(a)trl 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 5 920 4 0 69.9 110 130 130 94 10.51 118 8.3 3.4 '� 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 76.1 mm 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 T 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 w 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 1 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 108.Omm 920 3450 114.3 1 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 _ Mechanical-T cross assemblies 100 920 3450 114.3 96.80 1 146 92 239 159 ' 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with H DPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2Y50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2'BSPT clearly on order. §Vds approved for fire protection services a-PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_4 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. E Y �Z mm 920N -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 - 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 x 25 920N 3450 38.1 99 116 96 237 70 3.6 V - - 1�/4II 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 w 1/2(a)tR 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3(a)t o 920 4 0 88.9 110 140 130 92 10.51 135 10.2 8.8 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V T 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 TL 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 + 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 w 200 x 50 920 3450 69.9 138 157 159 122 316 1 114 5.3 5.3 2Y2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.7s 6.38 4.81 12.42 6.25 is.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal t Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services rt-PCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com iiictauliiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and (2)for the Style 920,920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for CvrKV Values: AP = Qz Where: AP = Qz Where: O C 2 Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(psi) V AP=Pressure Drop(Bar) Q = C x AP C =Flow Coefficient Q = K„x AP K =Flow Coefficient j Exaggerated for clarity OutletEquivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K,Values NOMINq AL • . � GROOVED '/z 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1'/< 1.660 50 48 32 42.7 5/z 6 42.9 41.1 1 Y2 1.900 53 53 40 48.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2'/2 2.875 1 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 1 1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. 1"FireLock-Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'dUI1C° 11.02_6 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Pi Run Size xt�al Outlet SizeJpe Rated Working Pressures—psi/kPa Size m Diameter S FTEW_ �O(Style920) (Style 920N) Inches/m Inches/mm *Inches mm ScPheldule UL IJLC dQ 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5Y125mm,67150mm and 87200 mm diameter pipe.The Style 931 comes with a 21h"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. X.A—c—tSUIiC® REV_O 11.02_7 rM1 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 L+tc�u�lC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 0 11.02_L �ZTISHURJOINTR) Threaded Fittings 1-01 www.shurjoint.com c&us FM 'W'. APNIINfO For Fire Protection pressure rating,listing,and approval information,visitShurjointwebsite, www.shurioint.com THREADED FITTINGS for details or contact your SHURJOINT Representative. Shurjoint offers a complete range of ductile iron Class 300 threaded fittings in sizes from %"to 2%". Material: Ductile iron ASTM A536 Gr. 65-45-12 and or Shurjoint ductile iron threaded fittings are 100% air ASTM A395 Gr. 65-45-15. tested underwater to ensure leak-free performance. Dimensions:ANSI B16.3 Class 150 except bushings and The Shurjoint ductile iron fitting series is UL listed plugs(1316.14), unions (B16.39)and companion flanges and FM approved, making them the right choice for (616.42). Please note wall thickness dimensions are fire protection and other general application services. subordinate to Shurjoint UL and FM pressure rating listings and approvals Threads:ANSI B1.20.1 NPT or ISO-7(BSPT) Finish: Black or electro-zinc plated • General Dimensions ' L These dimensions apply to all standard fittings, both straight and reducing. For center-to-face dimensions(*), - see fitting tables. Ductile Iron Class 300 threaded fittings are designed to the y. ' same dimensions as that of Class 150 malleable iron J E + H fittings.Though due to the superior strength characteristics, J ductile Iron fittings carry a much higher pressure rating. B j Laboratory tests confirm Shurjoint ductile iron fittings have T passed hydrostatic test pressures exceeding 6,000 psi/ 414 Bar,which is equal to four times the 1,500 psi/103 Bar as specified by ANSI B16.3 for 1%"—2"sizes. Size Band O.D. Band Width Thread Length(min) in in in in '/2 1.02 0.25 0.43 3/4 1.46 0.27 0.50 1 1.77 0.30 0.58 1'/4 2.15 0.34 0.67 1'/2 2.43 0.37 0.70 2 2.96 0.42 0.75 2%2 3.59 0.48 0.92 Installers who have not used DI threaded fittings before Burst pressure testing of DI threaded fittings(2") 0 should be instructed that the fittings are stronger than the pipe in most cases. In general DI threaded fittings require about a one-half turn less than cast iron fittings. Refer to the installation instructions for fiuther detail. Pressure-Temperature Ratin ANSI 11316.3&B16.14 Nom. Working Pressure • Rating @1 -G) Working Pressure Class �z —1":2000 psi/140 Bar 300 1%4"—2": 1500 psi/105 Bar 300 psi(20 Bar) 2'/2": 1000 psi/70 Bar *Proof test pressure:1.5 times the working pressure,non-shock cold water. I-01-1/6 Rev G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 811 ELBOW 900 Model . . 0' A--I size A Wt. BoxQ'ty in in Lbs PCs J '/2 1.12 0.25 240 L '/4 1.31 0.35 120 I 1 1.50 0.57 70 1'/4 1 1.75 1 0.97 1 40 1'/2 1 1.94 1 1.17 1 30 2 1 2.25 1 1.83 1 20 2'/2 2.70 3.34 1 10 MODEL 812 REDUCING ELBOW 900 ElbowModel 812 Reducing 90' B _ Size A B W. Box Q'ty in in in Lbs PCs ,. '/4X'/2 1.20 1.22 0.35 160 1 x'/2 1.26 1.36 0.46 110 1 x'/4 1.18 1.45 0.57 90 L P/4 x'/2 1.34 1.53 0.64 75 1'/4 x 1/4 1 1.45 1.62 0.68 60 1'/4 x 1 1.58 1.67 0.81 55 P/2 x'/2 1.41 1.66 0.84 45 1'/2 x'/4 1.52 1.75 0.90 45 1'h x 1 1.65 1.80 0.95 40 P/2 x P/4 1.82 1.88 1.10 35 2x3/4 1.60 1.97 1.19 1 30 2 x 1 1.73 2.02 1 1.47 25 2x11/2 2.02 2.16 1 1.61 20 2'/2 x 2 2.39 2.60 2.93 15 MODEL 813 ELBOW 450 ElbowModel 813 450 Size A Wt. Box Q'ty f in in Lbs PCs '/2 0.88 0.22 250 3/4 0.98 0.33 150 1 1.12 0.55 90 1'/4 1.29 0.84 50 P/2 1.43 0.92 35 2 1.68 1.63 18 2'/2 1 1.95 2.42 12 I-01-2/6 Rev.G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 814 TEE Model Tee - 1 Size A Wt. Box Q'ty m in Ibs PCs A '/z 1.12 0.31 150 '/a 1.31 0.48 90 1 1.50 0.81 60 1.75 1.28 35 A A� 1.94 1.72 24 01 2 2.25 2.57 12 2.70 4.44 8 MODEL 815 REDUCING TEE Model 815 Reducing Tee Size A B C W. Box in in in in Lbs PCs '/a %z 1.20 1.20 1.22 0.46 95 Yz 1 1.50 1.36 1.50 0.71 55 1 /z 1.26 1.20 1.36 0.59 80 1 '/a '/a 1.37 1.31 1.45 0.66 65 1 1.50 1.45 1.50 0.77 55 1 /z 1.26 1.26 1.36 0.64 1 65 ` '/a 1.37 1.37 1.45 0.75 60 '/z 1.34 1.26 1.53 0.79 50 1 '/a 1.45 1.37 1.62 0.88 50 1 1.58 1.50 1.67 1.01 45 1'/a 1'/a 1.75 1.67 1.75 1.25 40 '/z 1.34 1.34 1.53 0.84 45 1'/a '/a 1.45 1.45 1.62 0.99 45 1 1.58 1.58 1.67 1.12 40 '/z 1.44 1.31 1.69 0.92 40 '/a 1.50 1.37 1.75 1.01 40 1 1 1.65 1.50 1.80 1.19 30 1'/a 1.82 1.67 1.88 1.54 30 1%z 1.94 1.80 1.94 1 1.54 30 1'/ %z 1.41 1.34 1.66 1.08 40 1'A '/a 1.52 1.45 1.75 1.14 40 1 1.65 1.58 1.80 1.39 30 %z 1.41 1.41 1.66 1.10 35 1'/z '/a 1.52 1.52 1.75 1.17 35 1 1.65 1.65 1.80 1.36 30 1'/a 1.82 1.82 1.88 1.56 30 1 2 2.25 2.02 2.25 2.13 15 1'/a 2 2.25 2.10 2.25 2.22 15 %z 1.49 1.41 1.88 1.52 30 '/a 1.60 1.52 1.97 1.47 25 1'/z 1 1.73 1.65 2.02 1.63 20 2 1%z 2.02 1.94 2.16 2.09 20 2 1 2.25 2.16 2.25 2.33 15 '/z 1.49 1.49 1.88 1.56 20 1.60 1.60 1.97 1.61 20 2 1 1.73 1.73 2.02 1.80 20 P/a 1.90 1.90 2.10 2.09 20 1%z 2.02 2.02 2.16 2.24 15 2'/z 2 1 '/a 1.74 1.60 2.32 2.35 15 1-01-3/6 Rev.G 20120315 TSHURJOINT R' Threaded Fittings 1-01 www.shugant.com MODEL 815 BULLHEAD TEE Model 815 Bullhead Tee Size A B C At. Box C in in in in Lbs PCs '/4 '/4 1 1.45 1.45 1.37 0.66 65 1 1 1'/4 1.67 1.67 1.58 0.97 45 1'/z 1.80 1.80 1.65 1.15 35 1 1'/z 1.88 1.80 1.82 1.43 30 1'/4 1,/4 1%z 1.88 1 1.88 1.82 1 1.52 30 2 2.10 2.10 1.90 1.80 24 1 Yz 1'/4 2 2.16 2.10 2.02 1.94 20 1'/z 2 2.16 2.16 2.02 2.00 20 2 2 2%z 2.60 2.60 2.39 3.61 10 MODEL 816 REDUCING COUPLING Model 816 Reducing Coupling Size A Wrench Size At. Box in in in Lbs PCs : s '/4 x'/z 1.63 1'/4 0.37 150 1 x Yz 1.69 1 1/4 0.37 140 } 1 x'/4 1.37 1'/z 0.48 120 1'/4 x 3/4 2.06 1-'/z 0.59 80 1'/4 x 1 2.06 0.66 60 lYzxl 2.31 0.84 50 P/z x P/4 2.31 0.92 45 2 x 1 2.81 1.23 35 2 x 1'/4 2.81 1.28 30 2 x 1'/z 2.81 1.66 30 2'/z x 2 3.25 - 2.24 18 MODEL 817 CROSS B B--I . • - � size A B W. Box Q'ty A in in in Lbs PCs 1 1/2 1.12 1.12 0.48 90 1- 3/4 1.31 1.31 0.77 60 A 1 1.50 1.50 0.95 45 1'/4 1.75 1.75 1.43 25 1%z 1.94 1 1.94 1 1.87 1 20 2 2.25 2.25 2.86 10 A�A Model 817 Reducing Cross Size A B W. Box Qty in in in Lbs PCs 1'/xl'/a 1A 1.67 1.58 1.25 30 1'/A1 YAW 1.80 1.65 1.47 24 2x2xl xl 2.02 1.73 1.94 16 I-014/6 Rev G 20120315 TSHURJOINTR Th - " ' - ' Fittings 1-01 www.shugant.com MODEL 818 STRAIGHT COUPLING ,- Model 818 Straight Coupling Size A Wrench Size W. Box Q'ty i in in in Lbs PCs + I A /2 1.38 1'8 0.18 360 i I '/4 1.61 1%" 0.26 200 1 1.77 111/16" 0.42 110 1'/4 2.00 2" 0.57 75 1'/z 1 2.20 1 2'/4" 1 0.77 1 60 2 1 2.60 1 23/4" 1 1.17 1 30 2'/2 3.00 3%" 2.11 18 MODEL 820 CAP Model i Cap r size A VV1. Box Q'ty in m in Lbs Ya 0.89 0.14 500 I. '/4 1.00 0.20 300 1 1.18 0.33 180 1'/4 1.32 0.46 110 1'/z 1.38 1 0.57 80 2 1.48 1 0.88 1 45 2Y2 1.77 1.54 25 MODEL 825 EXTENSION PIECE Model Size A Wt. Box Q'ty in in Lbs PCs '/2 x 1'/zL 1.50 0.18 300 '/2 x 2L 2.00 0.22 250 t".., 3/4x1Y2L 1.50 0.22 250 '� 6 '/4 x 2L 2.00 0.26 200 f: AA MODEL 831 LONG STREET ELBOW 900 ElbowModel 831 Long Street • i ' all% size A B W. Box Q'ty in in in Lbs PCs i 1 x'/2M 1.50 3.00 0.66 80 g 1 x 1M 1.50 3.00 0.81 60 I-01-5/6 Rev.G 20120315 TSHURJOINTR Threaded Fittings 1-01 www.shugant.com MODEL 832 LONG STREET TEE Model 832 Long Street Tee C size A B C Wt I Box Q'ty in in in in Lbs Pes 1 x'/2XIM 1.50 1.40 3.00 0.91 50 -t-- IX1x1M 1.50 1.50 3.00 1.03 45 MODEL 827 HEX BUSHING Model 827 Hex Bushing Size A Wt. Box Q'ty in in Lbs PCs A I X'/2 1.06 0.20 280 1 x3/4 1.06 0.18 280 qW, 1'/4 X I 1.18 0.29 150 1'/2 x 1 1.26 0.53 100 Ph x P/4 1 1.26 0.37 100 2 x 1 1 1.34 0.75 80 2 x 1'/4 1 1.34 0.75 80 2 x 1'/2 1 1.34 0.64 80 MODEL 819 PLUG Model 819 Plug size A Wt. BoxQty in in Lbs PCs '/2 0.93 0.09 500 3/4 1.13 0.18 300 1 1.25 0.25 200 A 1'/4 1.36 0.42 110 1 Y2 1.45 0.59 80 2 1 1.50 1 0.95 1 45 General Notes: • Pressure ratings listed are CWP(cold water pressure)or rnaximum Aurking pressure widen the service temperature range ofthe gasket used in the coupling.This rating may occasionally differ from maximum NNurking pressures listed and/or approved by UT,ULC,and/or FM as testing conditions and test pipes differ.For additional information contact Shurjoint.. • NVhximum wutidng pressures and end loads listed are total of internal and extemal pressures and loads based on Sch. 10 steel pipe with roll grooves toANSFAWWAC606-07 specifications.For information on other pipe schedules contact Shurjoint.. • For one time field test only the maximum joint vwrking pressure may be increased 1'/2 times the figures shown. • Warning:Piping systems must always be depressurized and drained before attempting disassembly and or removal ofany components. • Shurjoint reserves the right to change specifications,designs and or standard equipment without notice and without incurring any obligations. Job Name: System No. Location: Contractor: Approved: Date: Engineer: Approved: Date: Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,please contact Shurjoint Technical Service.Shurjoint reserves the right to change or modify product design, construction, specifications,or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. I-01-6/6 Rev.G20120315 18204 59th Avenue NE • op ' • 14 Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Fire - Fire Sprinkler Permit Parcel:31052300200500 Permit#:26-0153 Permit Address:18725 67TH AVE NE Date Issued:February 26,2026 Description of Work:Fire Sprinklers for Salon PERMIT EXPIRES 180 DAYS Tenant Improvement AFTER DATE OF ISSUANCE. Valuation:$9600 Code Year: OWNER APPLICANT CONTRACTOR GRANDVIEWS IRONWOOD LLC Burns Fire Protection Systems,Inc Burns Fire Protection 20505 OLYMPIC PL NE SUITE 101 ARLINGTON, PO Box 1110 PO Box 1110,Granite Falls,WA 98252 WA,98223 3606912235 4253880124 audra@burnsfire.com audra@burnsfire.com registration number:BURNSFP841DU PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved plans. 2.) Permit shall be onsite for inspections. 3.) Call for inspections. INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance February 11, Processing/Technology(320.341.43.00.02) $25.00 2026 February 11, Fire System Plan Review(006.345.83.00.02) $200.00 2026 February 26, Fire Alarm System Permit(006.322.10.00.01) $750.00 2026 TOTAL: Permit Fees $975.00 $975.00 Credit/Debit Card 312 Payment Successful February 11, 2026 $200.00 $775.00 Credit/Debit Card 368 Payment Successful February 26, 2026 $775.00 $0.00 DA Area:::: �,l.69 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ S 06 i Design Area 7 Wei System EA ROO SALON TENANT SPACE ATIO Demand Calculations using Hazen-Williams Method Occupancy Classification: LH JI Design Area Density: 0.1 x m Additional Outside Hose: 250 Design Area Size: 1500 Notes: PER NFPA#13 2019 S I I AREA OF WORK TA ION I 72 T I I II I SCOPE OF WORK BY BURNS FIRE SYSTEMS THIS SUBMITTAL IS FOR THE MODIFICATION OF SPRINKLER PROTECTION TO EXISTING SPACE TO 70 CONFORM WITH NEW CEILING PLAN. SPACING OF SPRINKLERS IN ACCORDANCE WITH NFPA#13. ALL N EXISTING SYSTEM RISER ROOM NEW EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH NFPA STANDARDS. 1 7 NEW OR REPLACED SPRINKLERS TO MATCH K-FACTOR, TEMPERATURE RATING, FINISH AND KEY PLAN RESPONSE CHARACTERISTICS OF EXISTING SPRINKLERS. S 1 / 1 SCALE: N.T.S. S T N 7 O (18) TOTAL RELOCATED 70 PENDANT HEADS SUPPLIED FROM EXISTING 1" 13 OUTLETS t70 02 , (2) TOTAL ADDED > 1 NEW PENDANT HEADS SUPPLIED FROM NEW MECHANICAL TEE SPRINKLERS SPACED IN ROOMS IN ACCORDANCE WITH NFPA 13 SMALL ROOM RULE 061 10.2.5.2.3*The requirements of 10.2.5.2.1 shall not apply within small rooms as defined in 710 3.3.196 4�s 10.2.5.2.3.1 sprinklers shall be permitted to be located not more than 9 ft(2.7 m)from any single wall. 10.2.5.2.3.2 sprinkler spacing limitations of 10.2.5 and area limitations of Table 10.2.4.2.1(a) \ 1 shall not be exceeded. 7 S T 1 STATION 9 S1 A I ALL PIPING SHOWN IS EXISTING AND TO REMAIN U.N.O. - Approved o R s Steve Goforth,Fire Marshal Calculation results for Design Area 7 - SALON TENANT SPACE �l 9 1 � Subject to Field Review This system as shown on company print no dated o� for Ironwood Apartments Building 1 at 18725 67th Ave NE S7 2 02/25/2026 2:17:28 PM contract no is designed to discharge at a rate of 0.1 gpm/ft2(L/min/m2)of floor area over R a maximum area of 1500 ft2 when supplied with water at a rate of 263.3 gpm at 60.1 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: LH Number of heads flowing: 15 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 22.17 ft/s Storage arrangement: Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 60.1 psi Flow from Overhead sprinklers: 263.3 gpm Pressure Available at Source: 78.8 psi — - Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 18.8 psi Flow from Outside Hoses: 0 gpm 3. Other fixed flows: 0 gpm S4 Total flow in system piping: 263.3 gpm Additional flow at/beyond source: 250 gpm - 1 A.1i—4 Total of all flows: 513.3 gpm OFIRE PROTECTIONPLAN Floor First N CERT. #151760 Jennifer Yates C.E.T. N.I.C.E.T. Level III N NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN DATE DESCRIPTION BY BFPS, INC Ironwood Bldg 1 Salon T. I, E7- WASNINOTONSTATE� ������ SYM CNT POSITION FINISH TEMP K NPT SIN MPG. MODEL PERMIT NO. W O E 31'� FIRE SPRINKLER SYSTEMS ETENCY ®'zo PENo WHITE Tss s.eo /z vKsoz wKwc vKsoz David Yates P.O.B. 1110 18725 67th Ave NE David aces Level • CONTRACT No. GRANITE FALLS, WA APPROVAL CITY OF ARLINGTON . Bums Fire Protection Systems,Inc. : Arlington, WA 98223 S ; BURNSFPS41 qU ; DRAWN By J. 1'-0" 2;9i26 � 425-388-0124 SCALE 1/4" = 1'-0" Dole DESIGN QUESTIONS 360-580-1062 CONTRACTOR: RENSED DATE 2/9/26 FP 1 PLOTTED