Loading...
HomeMy WebLinkAbout16410 SMOKEY POINT BLVD STE 101_BLD6460_2026 i FIRE ALARM PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: 0 New Installation ❑ System Modification ❑ Phased Installation Property Address: 16410 SMOKEY POINT BLVD Suite No.: Project Valuation: 20000 Lot#: Parcel ID No.: 31 05529001 00800 Preferred Contact: O Owner 0 Applicant 0 Contractor Project Description: FULL BUILDING FIRE ALARM SYSTEM UPGRADE Owner Name: SMOKEY POINT PROFESSIONAL GROUP Phone No.: 4252395074 Email Address: DALE.DUSKIN@ME.COM Cell No.: 4252395074 Mailing Address: 1505 E 5TH ST city: ARLINGTON state: WA Zip: 98223 Applicant Name: NICK CHANDLER w/ FIRE PROTECTION INC phone No.: 4252909600 Email Address: NICK@FPISEATTLE.COM Cell No.: 4252909600 Mailing Address: 17410 ASH WAY, Ste 8 Cit : LYNNWOOD State: WA Zip: 98037 Contractor Name: NICK CHANDLER w/ FIRE PROTECTION INC phone No.: 4252909600 Email Address: NICK@FPISEATTLE.COM Cell No,: 4252909600 Mailing Address: 17410 ASH WAY, Ste 8 city: LYNNWOOD State: WA zip: 98037 L&I Contractor License Number: F I RE P I*021 M L Expiration Date: 07.3 1 .2025 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: 0 Complete and Scaled Plans 0 Specification Sheets 0 Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal Less than $5,000.00 = $200.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER Modification $125.00 = $ PERMIT FEE SUBTOTAL $ ✓❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices" Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $ PERMIT FEE TOTAL $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the ❑ Owner, ❑■ Applicant, ❑■ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Digitally signed by Nick Chandler DIN:cn=Nick Chandler, m NICK CHANDLER 4. 15.2025 email=nick@fpiseattle.com Date:2025.04.15 14:25:49-07'00' Signature Print Name Date REV2.2024 Page 2 of 2 NEW FIRE ALARM CONTROL PANEL Honeywell Analog and Networking Systems Do GWF-7075 Intelligent Fire Alarm Control Panel General The Gamewell-FCI®,GWF-7075 is an Addressable Fire Alarm Control Panel(FACP). The GWF-7075 has a signaling line circuit(SLC)loop that is used to connect the addressable detectors.The SLC loop is capable of supporting up to 75 detectors and 75 modules using the System Sensor'Velociti®Protocol,and it also offers the built-in support for the SWIFTT"wireless fire alarm devices. The GWF-7075 is equipped with two configurable Notification Appliance Circuits (NACs)that support a maximum output of 2.5A.This panel communicates with the built-in,dual-line digital and IP communicator including an optional cellular communication module. The GWF-7075 fire alarm control panel offers the following powerful features: • detector sensitivity • pre-trouble maintenance alert • day/night thresholds • calibration trouble alert GWF-7075 • drift compensation The GWF-7075 panel supports a variety of devices,including the following accessories: • RA-1000 Remote Annunciator • 5880-LED I/O Module • GFPS-6S Intelligent Remote Power Supply • 5824 SeriaVParallel Printer Interface Module(for printing system reports) FEATURES & BENEFITS • Built-in support for up • Contains a built-in USB • System programmable Supports up to four Offers a built-in to 75 detectors and 75 interface used for from the front panel SWIFT-wireless synchronization for modules operating in programming • Provides a built-in dual gateways.Each some models, Velociti°mode . Includes the phone line,digital gateway may include Note:To identify the • Offers a four line LCD programmable date alarm communicator/ up to 49 wireless compatible models,refer display with 40 setting for Daylight transmitter(DACT),I devices to the Compatibility characters per line Saving Time or optional cellular Supports Class B(Style Addendum to Gamewell- • Available in a red or a • Uses a JumpStart Auto technologies 4)and Class A(Style 6 FCI Manuals, black cabinet Programming°feature Firmware can be or Style 7 configuration P/N:9000-0427-L8. • GWF-7075 can be for easy programming upgraded in the field for SLC,and SBUS surface or flush • Reports events to the mounted Central Station by point or by zone Optional Accessories COMPATIBLE DEVICES RA-1000: Remote Annunciator For a list of compatible devices,refer to the following The RA-1000 is a remote annunciator used to operate documents: the GWF-7075 Fire Alarm Control Panel(FACP).It • Compatibility Addendum for Gamewell-FCI connects to the control panel via the RS-485 system Manuals,P/N:9000-0427-L8 bus.The RA-1000 is equipped with five status LEDs • SWIFT''Intelligent Wireless Detectors, which indicate: P/N:9021-60818 • Alarm • AC Power Loss • SWIFT'Intelligent Wireless Modules, • System Silenced • Trouble P/N:9021-60819 • Supervisory • SWIFT TM Wireless Gateway,P/N:9021-60824 GFPS-6S: Intelligent Remote Power Supply ORDERING INFORMATION The GFPS-6S intelligent power supply delivers 6A of Notification Appliance Circuit(NAC)power and offers GWF-7075: Intelligent Fire Alarm Control Panel.Red GWF-7075B:Intelligent Fire Alarm Control Panel, built-in synchronization for some appliances Black developed by the following manufacturers. SBUS Accessories • System Sensor' • FaradayT" RA-1000:Remote Annunciator(Black) • Gentex° • AMSECOT"' Dimensions: 7.4"H x 9.1"W x 1.5" • WheelockTI (18.8 x 23.1 x 3.8)cm Note:Sync Feature Restriction:Notalldevices can usetheSync RA-1000R:Remote Annunciator(Red) Feature.To ensure thatthe selected device works with the Sync GFPS-6S:Intelligent Remote Power Supply Feature,referto the Compatibility Addendum to Gamewell-FCI Manuals,P/N:9000-0427-1-8. Dimensions:16"H x 12.25"W XD (40.6 x 30.9 x 7.6)cm The GFPS-6S provides its own AC power connection, 5824:Serial/Parallel Module battery charging circuit,and backup battery for use Dimensions: 6"H x 7.75"W x 1.44"D with the GWF-7075 FACP.The output circuits can be (15.0 x 19.4 x 3.6)cm programmed as NACs or as auxiliary power 5880:LED 1/0 Module (configurable for constant,resettable,or door holder Dimensions: 7.75"H x 6"W x 1.94"D power). (19.4 x 15.0 x 4.8)cm 5220: Direct Connect Module 5824: Serial/Parallel Module Dimensions: 1.31"H x 6.5"W x 2.13"D The 5824 is equipped with one parallel and one RS- (3.33 x 16.51 x 5.40)cm Miscellaneous Accessories 232 serial port that allows the GWF-7075 to connect to HFSS:Software Suite.Provides programming,upload/ virtually any standard PC-compatible printer to download and event reporting generate reports on site. BB-17F:Remote Battery Box Cabinet.Holds up to two 18 Amp Hour batteries. 5880: LED I/O Module Dimensions: 16"W x 10"H x 6"D The 5880 provides 40 programmable LED outputs and (40.64 W x 25.40 H x 15.24 D)cm eight supervised dry contact inputs.These devices CELL-MOD: Cellular Communicator in Plastic offer an effective way to customize remote Enclosure annunciation.The GWF-7075 supports up to eight 5880 modules to offer maximum flexibility. 5220: Direct Connect Module The 5220 is a direct connect module used to connect a fire alarm control panel(FACP)to a city box or polarity reversal communicator. CELL-MOD:Cellular Fire Alarm Communicator (Plastic Enclosure) The CELL-MOD houses the GSM communicator inside a plastic enclosure that may or may not require an external antenna depending on the installation environment. 2 GWF-7075 Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and PHYSICAL: The GWF-7075 is designed to comply with the certifications,please visit: Overall Dimensions: 15.12"H x 12.71"W x 3.33"D following standard: http://www.gamewell- 38.40 H x 32.28 W x 8.46 D cm UL Standard: UL 864 9th Edition fci.com/en-US/ documentation/Pages/ Weight: 25 lbs. NFPA STANDARDS Listings.aspx Color: Red or Black NFPA 13 Sprinkler Gamewell-FCI°,System Environmental Operating Temperature: 32o Ftol20o F NFPA 15 Water Spray Sensor'and Velociti°are (0°C to 49°C) registered trademarks and Humidity: 0 to 93%relative humidity NFPA 16 Foam Water SWIFT-is a trademark of (non-Condensing) NFPA 70 Honeywell International,Inc. NFPA 72 AMSECOTM is a registered ELECTRICAL: Central Station trademark of Kobishi America GWF-7075 Primary AC: 120 VAC C 60 Hz, Remote Signaling Inc. 900mA Total Local Protective Signaling Systems Asco®is a registered Accessory Load: 2.5A @ 27.4 VDC Class A Auxiliary Protected Premises Unit&Water Deluge trademark of Asco Power Power-Limited Releasing Service Technologies Inc. NAC Power: 1A per NAC,2.5A Total AGENCY LISTINGS AND APPROVALS Farraday-is a trademark of Aux Power: 27.4 VDC Faraday LLC. Form C Trouble&Alarm Relay: 2.5A @ 27.4 VDC, These listings and approvals apply to the modules Gentex°is a registered specified in this document.In some cases,certain trademark of Gentex Resistive modules or applications may not be listed by certain Corporation Inc. Standby Current: 165 mA approval agencies,or listing may be in process. Alarm Current: 310 mA Consult factory for latest listing status. Microsoft,Windows®,and the Battery Charging Capacity: 7 to 35 AH UL:S1869 Windows Logo'are registered trademarks or trademarks of Battery Size: 7 A/H maximum allowed in the control CSFM:7165-1703:0500 Microsoft Corporation. panel cabinet.Larger capacity batteries can be housed FD NY:COA-6255 ULI in the BB-17F accessory cabinet. OSHPD(CA) of a registered trademark of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES Approved Releasing Solenoids: Inc. This system meets NFPA requirements for operation at 0 Asco°T821OA107 24 VDC 3 A max.0 Hz Wheelock'"is a trademark of —491C/32—120°F and at a relative humidity 93% 2% Asco°821OG207 24 VDC 3 A max.0 Hz Cooper-Wheelock Inc. RH(noncondensing)at 32°C 2°C(90°F 3°F). ISO 9001 Certification However,the useful life of the system's standby batteries This document is not intended and the electronic components maybe adversely affected to be used for installation by extreme temperature ranges and humidity. Therefore, purposes.We tryto keep our product information up-to- it is recommended that this system and its peripherals be date and accurate.We cannot installed in an environmentwith a normal room coverall specific applications temperature of 15—27°C/60—80°F. or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's GWF-7075 and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 Honeywell 9021-60966 C 05/19 www.honeywell.com ©2019 Honeywell International Inc. NEW REMOTE POWER SUPPLY IPF� PS 6 Amp and 10 Amp, 24 Volt Power Supplies The HPF-PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The HPF-PS Series is a remote power supply line from Honeywell and is a direct replacement for the GFPS6/9.The HPF-PS6(B)is a 6 amp and the HPF-PS10(B)is a 10 amp,remote power supplies with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a standalone power supply.The HPF-PS Series provides 24 VDC power for NACs(notification appliance circuits)configured as either Class B or Class A (requires the ZNAC-PS option card)with multiple sync protocol options.The HPF-PS Series also provides auxiliary power,constant or resettable,suited ford etectors,annunciators,door holders,and other fire alarm system peripherals.The HPF-PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five(6 amp model)or seven(10 amp • 6 or 10 amp full load output,respectively, HPF-PS6110 model)independently-configurable,power- with 3 A maximum/circuit limited output circuits for: • Individual NAC power and trouble LEDs for —Class B and/or Class A NACs diagnostic efficiency —Class B and/or Class A resettable or non- • Trouble history mode for diagnostic support resettable 24V auxiliary power • Wide range end-of-line supervision value —door holder power (normal:2-27K ohms) • Converts from Class B to Class A wiring • Selectable earth fault detection(enable or without losing any outputs using the disable) ZNAC-PS converter card(sold separately) • AC trouble report delay timer POWER SUPPLY • Optimal for powering four-wire smoke • Completely configurable via onboard DIP detectors,annunciators,and other system switches,no extra software required peripherals requiring regulated power • Self-contained in compact,locking cabinet • Optional addressable control,monitor,and constructed of heavy gauge steel with a relay modules and power-supervision relay corrosion-resistant powder coat chip and (EOLR-1) scratch-resistant finish • Configurable for ANSI°Temporal or • Cabinet designed with ten double Temporal 4 coded output knockouts and a removable door for ease of • UL-Listed NAC synchronization using installation and wiring System Sensor',Wheelock',Gentex°,or • Includes integral battery charger capable of HPF-PS6110B AMSECO°appliances charging up to 33 AH batteries • Synchronization can be triggered from • Cabinet can house two 7 AH or 18 AH FACP NAC/remote sync outputs,cascaded batteries power supply,or a control module,single or • Battery charger may be disabled via DIP multi,which may be housed within the switch for applications requiring larger power supply cabinet batteries and external battery charger • Ability to cascade up to four power supplies • Removable terminal blocks accommodate • Two(6 amp model)orthree(10 amp model) up to 12 AWG(3.1mm2)wire fully-isolated input/control circuits which . Works with any UL 864 FACP which utilizes can be programmed to any output an industry-standard reverse-polarity• Two Form Cnormally-closed trouble relays notification circuit HonGHoneywellfor AC Trouble and General Trouble bommw amewell ORDERING INFORMATION HPF-PS6:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS6B:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black HPF-PS10:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS1013:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black ZNAC-PS:Optional Class A converter card,sold separately 50152254-001:Hardware kit for Canadian applications 17070:Alternate Gamewell-FCI lock set AOM-2SF:Addressable Control Module for one Class B or Class A zone of supervised,polarized Notification Appliances.Notification Appliance Circuit option requires external 24VDC to power notification appliances. AOM-2RF:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch AMM-4F:Addressable Monitor Module for one zone of normally open dry-contact initiating devices.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Class B or Class A AMM-21F:Dual Monitor Module.Same as AMM-4F except it provides two inputs for Class B wiring only AMM-2RIF:Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only MMO-6SF:Six-circuit supervised control module MMO-6RF:Six Form-C relay control module EOLR-1:12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP:Battery,12 volt,7.0 AH,5-pack(two required) BAT-12180-BP:Battery,12 volt,18AH,2-pack BAT-12330:Battery,12 volt,33AH SEISKIT-MULTI-1:Seismic kit for the HPF-PS Series.Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3—9021-61096:D•8/15/2023 HPF - _ SERIES TECHNICAL SPECIFICATIONS PRIMARY(AC) Puvvr-K STANDARDS AND CODES H PF-PS6(B):120 VAC,50/60 Hz,5.OA The HPF-PS complies with the following Gamewell-FCII and System Sensor' maximum standards: are trademarkof Honeywell HPF-PS10(B):120VAC,50/60 Hz,6.2 A NFPA 72:National Fire Alarm Code International,Inc.Wheelock"is a maximum UL 864:Standard for Control Units for Fire Technologiesregistered trademark�• _ o Wire Size:#12-14 AWG with 600 V Alarm Systems(NAC expander mode) is insulation UL 1481:Power Supplies for Fire Alarm a registered trademark of Gentex Corporation. • COMMAND INPUT CIRCUIT Systems registered trademark of Potter Trigger Input Voltage:9 to 32 VDC AGENCY LISTINGS AND Electric Signal Company, Trigger Current:2.0 mA(16-32 V);Per APPROVALS ANSI'is a registered trademark of Input:1.0 mA(9-16 V) These listings and approvals apply to the the American National •• • RELAY CIRCUITS modules specified in this document.In Institute, Inc. some cases,certain modules or @2023 , Honeywell Trouble Contact Rating:4 A at 24 VDC applications may not be listed by certain reserved.Inc.All rights OUTPUT CIRCUITS approval agencies,or listing may be in process.Consult factory for latest listing Unauthorized ' document • 24 VDC filtered status. is strictlyprohibited. • HPF-PS6(B):TB8-TB9—1A Regulated,3A UL Listed:S24562 This document is not intended be special applications;T610-TI312—0.3A CSFM:7315-1637:0505 used for Regulated,3A special applications FDNY COA: • • our installationproduct • HPF-PS10(B):TB8-TB11-1.5A Regulated, 2022-TMCOAP-002231-AMND up-to-date and accurate.We 3A special applications;TB12-TB14—0.3A FM Approved cover all specificapplications or Regulated,3A special applications anticipate all requirements.• 6.0 A(HPF-PS6(B))or 10.0(HPF-PS10(B)) specifications _ctto change maximum total continuous currentfor all without notice. outputs SECONDARY POWER(BATTERY) Country of origin:USA CHARGING CIRCUIT • Supports lead-acid batteries only • Float-charge voltage:27.6 VDC • Maximum current charge:1.5 A • Maximum battery capacity:18 AH(inside cabinet) • Maximum battery charging capacity:33 AH (external cabinet) PHYSICAL Dimensions:20.0"H x 14.5"W x 3.5"D(cm: 50.8H x 36.83W x 8.9D) Weight:with two 7Ah batteries is 24 pounds (10.9 kg),with two 18 AH batteries is 39 pounds(17.7 kg) Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 9021-61096 1 D 1 08-23 QGamewell www.gamewell-fci.com ©2023 Honeywell International Inc. NEW WIRELESS COMMUNICATOR ES CORPORATION O 7707 Fire Subscribers ' IntelliNet Feature Highlights • Offers flexible power and configuration options. Engineered for backward compatibility with legacy systems. Enables future ready capabilities. • Provides instant Subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button. Includes dual communication/multiple • communication technology(reporting over RF and c U` W I P). • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets, and PCs. Key Benefits Built upon the solid foundation of AES-IntelliNet°patented mesh radio technology for use in private licensed wireless networks. • Protects Subscriber units against unauthorized access and rogue activity with a password protected Dealer Code. • Makes programming and streamlined troubleshooting easy with user friendly interface. • Adds integrated supervision of 7794A AES-IntelliPro full data module. • Provides versatile power options. Models SubscriberslntelfiNeOl 2.0 Fire 7707P-88-M IntelliNet 2.0 Fire Subscriber,8-Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber,8-Zone with 7794A AES-IntelliPro and Integrated Onboard Local Annunciator, plus Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised)with 7707P 44 M Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber,4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro and Integrated oOnboard Local Annunciator, plus Multiple Communication Technologies MCT, Red Enclosure aes-corp.com Technical Specifications DIMENSIONS ALARM SIGNAL INPUTS/ZONES ANNUNCIATOR 13"H x 8.5"W x 4.5"D 8 Individually programmable Integrated Local Annunciator (33cm H x 21.5cm W x 11.4cm D) E.O.L.type zone inputs • 4x4 Option with 4 reverse PROGRAMMING INTERFACE WEIGHT polarity input and 4 Web browser capable device • 15.85 Ibs(7.2 kilograms)with individually programmable accessible via smartphone,tablet, 12Ah battery E.O.L.type zone inputs laptop,or PC • 7 Ibs(3.2 kilograms)excluding Optional 7794A AES-IntelliPro battery for full data via Contact POWER OUTPUT ID, Pulse, Modem Ile,and 2 or 5 Watts RADIO FREQUENCY Modem Illa2 Contact AES for other options Standard Frequency Range: 450-470 MHz UL LISTINGS ENCLOSURE MATERIAL Contact AES for other UHF UL 864 Standard for Control Metal with paint finish and VHF frequencies Units and Accessories for Fire Alarm Systems, Edition 10 FINISH COLOR ANTENNA ULC 5559-04 Equipment for Red 2.5 dB Tamper resistant antenna Fire Signal Receiving Centers included and Systems, Edition 1 VISUAL INDICATORS • Front panel LCD(2 x 20 POWER INPUT TROUBLE OUTPUT—ACK alphanumeric character backlit • 16.5V AC Class 2 Transformer DELAY/ANTENNA CUT display) Transformer not included Form C relay,fail secure, Power and Trouble LEDs(ALM, • 24V DC External Regulated rated 24V DC 1A resistive, Trouble,Tx, Rx,WA) Power Supply unsupervised Menu/Silence button • 24V DC Regulated Power Supply from FACP AUX Power RESET BUTTON Located on main circuit board BACKUP BATTERY 12 Ah with 7794A; 6 Ah without, OPERATING TEMPERATURE UL recognized lead acid gel cell 32 to 120°F(0 to 49°C) battery Size based on Subscriber STORAGE TEMPERATURE configuration 14 to 140'F(-10 to 60'C) CURRENT CONSUMPTION RELATIVE HUMIDITY Backup Battery Power 0 to 93%, non-condensing • Standby=.190A • Transmit=.752A PORTS • Optional 7794A= .165A, (1) Ethernet Standby and Alarm (2) USBs f in o aes-corp.com AES Corporation 285 Newbury St. I Peabody, MA 01960 United States O 2023 AES Corporationand AES-IntelliNet@ are registered trademarks ofAES Corporation. / - 10252023 BATTERY CALCULATIONS 1)Select the AES model from the AES Model field. 2)Select if Intellipro is installed 3)Select if Ethernet Cable is installed during normal operation. (Only applies to 2.0 subscribers) 4)Select if 7762 is installed (Only applies to 7788F) 5)Enter the#of hours of backup time required.AES products are UL listed for 24 hours operation on battery backup. 6)The calculator will return the recommended minumum battery capacity and max primary input DC and AC current BACKUP BATTERY CALCULATIONS AES Model 7794A Ipro Ethernet Cable #Hours Backup Installed Installed Time 7177 Yes Yes No 24 Standby Current Intellipro Current Ethernet Current 7762 Current Total Standby (Amps) (Amps) (Amps) (Amps) Current(Amps) 0.175 + 0.165 + 0.015 + 0.000 = 0.355 #Hours Backup Standby Current Required Standby Time (Amps) Capacity (Amp-Hours) 24 x 0.355 = 8.52 Transmit/Alarm Required Alarm Required Alarm Current(Amps) Time(Hours) Capacity (Amp-Hours) 0.786 x 0.25 = 0.20 Required Standby Required Alarm Total Required Capacity Capacity Backup Capacity (Amp-Hours) (Amp-Hours) (Amp-Hours) 8.52 + 0.20 = 8.72 Total Required Recommended BackupCapacity *Recommended Minimum Battery p y Safety Factor Capacity ***The battery requirements presented here are (Amp-Hours) *** only AES recommendations. (Amp-Hours) 8.72 x 125% = 10.9 NEW REMOTE ANNUNCIATOR Honeywell 17075 Series 829 ewell M M RA-1000 Remote Annunciator General The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels(FACPs).The RA-1000's keypad and display match the built-in annunciator of the GWF-7075 fire alarm control panel.The remote annunciator connects to the fire alarm control panelvia the RS-485 system bus.When the system is in normal operation and has AC power,the Power LED is lit and all other LEDs are off.When any of the following conditions occur,the following LEDs turn on: lir • Alarms • Supervisories, • Troubles • System Silenced • AC power losses V V v Q Installation © uvv The RA-1000 can be surface or flush-mounted.Use the optional trim ring for surface © V V V 0 ■ mounts.The flush-mount electrical box is optional.Ifyou require an electrical box,use O Gl O a 4S,single-gang or double-gang box. Compatibility The RA-1000 is compatible with the following FACPs: RA-1000 • GWF-7075 Intelligent Fire Alarm Control Panel Ordering Information RA-1000R:Remote Annunciator.Four line LCD annunciatorwith 20 characters per line,red. RA-1000:Remote Annunciator.Four line LCD annunciatorwith 20 characters per line, g ray. Accessories: 5860TR:Red Trim Ring for surface mounting. 5860TG:Gray Trim Ring for surface mounting. FEATURES & BENEFITS • Enclosure available in Includes the following The remote Provides an on-board Use wiring lengths up red or light gray five status LEDs: annunciator operation piezo sounder with to 6,000 ft.from the • Produces audio - alarm and appearance is audio that broadcasts FACP(depending on feedback identical to the alarms,troubles,and the wire gauge and the - supervisory GWF-7075 built-in supervisories number of devices on • Accepts the user codes - trouble annunciator the SBUS) or the fire fighter's key - silence • Installs up to eight RA- • Offers an RS-485 - AC power conditions 1000s per GWF-7075 interface to the panel Has an 80-character backlit LCD display ' Supports a • Displays large keypad simultaneous use of buttons for system that shows 4 lines with multiple RA-1000s reset and silence 20 characters on each line RA-1000 RA-1000 RA-1000 Note 1:Install up to 8 RA-1000s per System for the GWF-7075. Note 2:Includes an 80-character backlit LCD display. (4 lines with 20 characters each). Note 3:Use wiring lengths up to 6,000 ft.from the fire alarm control panel. Figure 1 RA-100 Panel Setup 2 RA-1000 Technical Specifications SYSTEMS Standards For a complete listing of all compliance approvals and Physical: The GFPS-6S is designed to comply with the following certifications,please visit: Height: 7.4"(18.8 cm) standard: http://www.gamewell- Width: 9.1"(23.1 cm) UL Standard:864 9th Edition and 1481 fci.com/en-US/ documentation/Pages/ Depth: 1.5"(3.8 cm) Agency Listings and Approvals Listings.aspx Shipping Weight: 2.8 lbs(1.3 kg) These listings and approvals applyto the modules Gamewell-FCI°and Color: specified in this document.In some cases,certain Honeywell'are registered RA-1000R: Red modules or applications may not be listed by certain trademarks and FarenhyteT"is RA-1000: Gray a trademark of Honeywell Electrical: approval agencies,or listing may be in process. International,Inc. Operating Voltage: 24 VDC Consult factory for latest listing status. Gentex°is a registered Standby Current: 20 mA max UL: 864 trademark of Gentex Alarm Current: 25 mA 1481 listed Corporation. Wiring Distance: 6,000 max.from FACP(depending on CSFM approved Jumpstart is a registered wire gauge and number of devices on the SBUS) M EA approved trademark of Silent Knight. Environmental: ISO 9001 Certification Microsoft,Windows®,and the Operating Temperature: 320E-120OF(0°C—49°C) Windows Logo°are registered Humidity: 10%—93%non-condensing trademarks or trademarks of TEMPERATURE AND HUMIDITY RANGES Microsoft Corporation. This system meets NFPA requirements for operation at 0 System Sensor'is a registered —491C/32—120°F and at a relative humidity 93% 2% trademark of System Sensor. RH(noncondensing)at 32°C 2°C(90°F 3°F). UL®is a registered trademark However,the useful life of the system's standby batteries of Underwriter's Laboratories and the electronic components may be adversely affected Inc. by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be Wheelock'is a registered installed in an environmentwith a normal room trademarkofWheelock,Inc. temperature of 15—27°C/60—80°F. This document is not intended to be used for installation purposes.We tryto keep our product information up-to- date and accurate.We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's RA-1000 and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9021-601007 1 A 1 11/17 H o n eywe I I www.honeywell.com ©2017 Honeywell International Inc. NEW ADDRESSABLE SMOKE DETECTORS Honeywell I Addressable Devices ^2amSewell l Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti°Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern bright white color,the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. / The Velociti Series 3 smoke detectors are intelligent addressable detectors with point J ID capabilitythat enable each detector address to be setwith rotary address switches I / providing exact device locations.The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern z design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series°and S3 Series panels support both the Velociti°and CLIPT"protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotaryaddress Includes dual LEDs for Offers expanded color Standard 268 7th functionaltest switch switches(01-159) 3601 visibility options Edition activated by external • Supplies optional relay, • Designed with a new magnet isolator,or sounder profile to offer modern • Supports a low standby bases(standard or low and improved current frequency) aesthetics Ordering Information Ordering Information NOTE: AV"suffix indicates Ivory color model. Accessories NOTE:"-BL'suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. ASD-PL3:Photoelectric smoke detector,bright white, TR300:Accessory Flange Ring for B300 6"Base,bright Velociti white ASD-PL3R:Photoelectric smoke detector,remote test TR300-IV:Accessory Flange Ring for B300 6"Base,ivory capable,for use with DNR(W)duct smoke detectors,bright RA10OZ: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with B501 and 3300-6. sensing,bright white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV:Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF CLIP Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,referto Data Sheet M02-04-01: Detectortest magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR213: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high B501-WHITE: 4"Flangeless mounting base,bright white ceiling applications. B501-WHITE-BP:4"Flangeless mounting base bulk pack, XP-4: Extension pole for XR2B.Shipped with three,5-foot bright white (1.524,m)sections. B501-IV: 4"Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,brightwhite B300-6-IV:6°Flanged mounting base,ivory B300-6-BP:6°Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,bright white B200SR-IV:Standard sounder base,ivory B20OS-WH:Intelligent addressable sounder base,bright white B20OS-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, bright white B200SR-LF-IV:Standard low frequency sounder base, ivory B20OS-LF-WH:Intelligent addressable low frequency sounder base,bright white B20OS-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white B224BI-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti° Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Photoelectric Intelligent Detector: The Velociti°Series 3 Photoelectric Detectors are certifications,please visit: Physical Specifications designed to comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3 Series®,Velociti®and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI°are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of Honeywell Operating Temperature Range: approval agencies,or listing may be in process. International Inc. Photo:321 F to 1221 F(01 C to 501 C) Consult factory for latest listing status. UL®is a registered trademark Photo in Duct Applications:-41 F to 1581 F UL:S2332 of Underwriter's Laboratories (-20°C to 70'C) FM:3023594 Inc. Photo with Thermal:32'F to 100'F(0'C to 381 C) M EA FDNY:COA-219-02-E Vol.VI This document is not intended Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to be used for installation non-condensing ISO 9001 Certification purposes.Wetryto keep our Rate-of-Rise Detection:Responds to greater than product information up-to- 150F/minute or 1350F(8.3°C/minute or 57°C date and accurate.We cannot Range: 0 to 4,000 ft/min cover all specific applications Air Velocity g or anticipate all requirements. (0to 1219.2 m/min) All specifications are subjectto Electrical Specifications change without notice. Voltage Range: 15 to 32 VDC Standby Current(C 24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA @ 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti®Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0617 I K 104/2018 Honeywell www.honeywell.com ©2018 Honeywell International Inc. NEW ADDRESSABLLE PULL STATIONS Honeywell I Addressable Devices QGamewell 2 � n. MS-7 Series Manual Fire Alarm Pull Stations General The Gamewell-FCI,MS-7 Series man ualfire alarm pull stations are available in a wide . variety of configurations.The pull stations comply with the Americans with Disabilities Act(ADA)5-lb.maximum pull force requirement.Operating instructions and Braille text are engraved in the handle.All pull stations include a key lock/resetwhich is keyed PUSH IN alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull PULL DOWN stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti'Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the pull station causes its assigned address to register at the fire alarm control panel.The door contains an LED which flashes no � green in normal condition and lights steady red when the station has been activated.* The station features screwterminals. MS-7Series MS-7ASF Velociti Addressable Station The MS-7ASFVelocitia Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the station causes its assigned address to register at the control panel.The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.*The station features screw terminals. The Velociti'Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and focuses on the single device.The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels.It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations • The pull stations(MS- • Offers surface or semi- Includes a tumbler lock *Only the red LED is compatible with all 7LOB)are Listed for flush mounting for test and reset keyed operative in panels that Gamewell-FCI analog outdoor applications alike with analog do not operate in Velociti addressable fire alarm • Shock and vibration addressable fire alarm mode controls • Complies with ADA pull resistant controls force requirements • Conventional stations • Both single and double suitable for use with action pull stations any UL Listed control available panel MS-7S Single Action Station NYC-Plate The MS-7S single action pull station is used with The NYC-Plate provides the backplate for the manual conventional fire alarm control panels.It features a set pull station.(See Figure 1). of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station,with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for usewith the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems.It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort Figure 1 NYC-Plate The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities Ordering Information and Flex Series releasing systems where system abort MS-7:Double action station capabilities are required.It consists of the following: MS-7AF**:Velociti addressable double action station • An MS-7LR mounted on a plate with an abort switch MS-7ASF**:Velociti addressable single action station • LED indicators that signal system normal and MS-7S:Single action station,wire leads system activated status MS-7LOB Double Action Station(Listed for Outdoor MS-7SP:Double action station,English and Spanish Applications) instructions The MS-7LOB station must be mounted on a Model MS-7LR:Agent release station,dual-action SB-I/0 backbox.In retrofit applications,the pull MS-7LRA:Agent release station with abort switch, station is UL Listed for use with the WP-10 backbox.It LED indicators,dual-action is intended for use with conventional control panels MS-7LOB:Double action station,outdoor use and has a set of single pole contacts and screw (Includes SB-I/0-Indoor/outdoor use backbox) terminals. SB-I/O:Indoor/outdoor use backbackbox Mounting The MS-7 interior pull stations may be surface SB-10:Surface backbox mounted or semi-flush mounted on a standard BG12TR:Trim ring for semi-flush mount,plastic double-gang,or4-inch(10.2 cm)square electrical box. NY-PLATE:NYC backplate for manual pull station An optional trim ring(BG12TR)may also be used for semi-flush mounting. **For use with the Gamewell-FCI analog addressable control panels only. 2 MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all The MS-7 Series is designed to com with the following compliance approvals and l Material:Lexan® g py g certifications,please visit: Contact Ratings:0.25 amps.C 30 VAC/VDC(resistive) standard: http://www.gamewell- Dimensions:5 5/8"H x 41/4"W x 11/4°D UL Standard:UL 864 9th Edition fci.com/en-US/ (14 x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx Operating Temperature: These listings and approvals apply to the modules (MS-7AF,MS-7ASF):320 to 1200 F(01 to 491 0L Is a registered specified in this document.In some cases,certain trademark of GE Plastics,a (MS-7 LOB):-300 to 1500 F(-351 to 661 C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies,or listing may be in process. Company. (MS-7AF,MS-7ASF):10 to 93%(non-condensing) Consult factory for latest listing status. g UL:S2465 Velociti°and Gamewell-FCI (MS-7LOB):85% 5%C 86° 3.60(300 20 C) are registered trademarks of Alarm Current:.0030 amp.0.007 for LED FM:3023594 Honeywell International Inc. Supervisory Current: MEA FDNY:67-02-E Vol.VI I UL°is a registered trademark (MS-7AF,MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. This system meets NFPA requirements for operation at 0 7160-1703:0170 This document is not intended —491C/32—120°F and at a relative humidity 93% 2% 7160-1703:0109 to be used for installation RH(noncondensing)at 32°C 2°C(90°F 3°F). ISO 9001 Certification purposes.We tryto keep our However,the useful life of the system's standby batteries product information up-to- and the electronic components maybe adversely affected date and accurate.We cannot coverall specific applications by extreme temperature ranges and humidity. Therefore, or anticipate all requirements. it is recommended that this system and its peripherals be All specifications are subjectto installed in an environmentwith a normal room change without notice. temperature of 15—270C/60—80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 H o n eywe I I www.honeywell.com ©2017 Honeywell International Inc. NEW ELEVATOR RECALL RELAYS Honeywell I Addressable Devices 827 2 � n. Velociti Series"' AOM-2RF Addressable Output Relay Control Module General The Gamewell-FCI Velociti®Series,addressable output relay control module(AOM- 2RF)allows a Gamewell-FCI analog addressable fire alarm control panel to switch r_1 discrete relay contacts by code command.The relay provides two isolated sets ofForm-C contacts which transfer simultaneously.Circuit connections to the relay ' contacts are not supervised by the module. The Velociti®Series use a communication protocol that substantially increases the �• �� ~~ speed of communication between the SLC devices and certain Gamewell-FCI analog 1/I 1ll addressable fire alarm control panels.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and concentrates on the single device.The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any AOM-2RF Gamewell-FCI analog addressable fire alarm control panel.The module contains a panel controlled LED.The AOM-2RF is designed to mount in a 4"(10.16 cm)square junction box 21/8"(5.53 cm)deep. Ordering Information AOM-2RF:Addressable output relay control module Table 1 lists the relay contact ratings. CURRENT MAXIMUM LOAD RATING VOLTAGE DESCRIPTION APPLICATION 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30 UDC Inductive Coded (L/R=5ms) 1A 30 VDC Inductive Coded (L/R=2ms) 0.5A 125 VAC Inductive Non-Coded (PF=.35) 0.7A 75 VAC Inductive Non-Coded Table 1:Relay Contact Ratings FEATURES & BENEFITS • Listed under UL® Provides visual rotary, Includes a bi-color LED Designed as a compact Note 1:Only the red LED Standard864 decimal switch that flashes green size to allow easy is operative in panels that addressing(01-159) wheneverthemoduleis installation donotoperateinVelociti® • Offers two sets of Form addressed,and lights mode "C"contacts stead red upon p on Note 2:The bi-color LED activation* functionality is not available on the GWF-7075 panel. Velociti Series° AOM-2RF Technical Specifications SYSTEMS STANDARDS For a complete listing of all The Velociti Series AOM-2RF is designed to comply with compliance approvals and ° Supervisory Current:.000375 amps. g p y certifications,please visit: Alarm Current:.0065 amps. the following standard: http://www.gamewell- Operating Temperature:321 to 1201 F(00 to 49'C) UL Standard:UL 864 9th Edition fci.com/en-US/ o AGENCY LISTINGS AND APPROVALS documentation/Pages/ Relative Humidity:10 to 93/o relative humidity(non- Listings.aspx condensing) These listings and approvals apply to the modules Velocitio Series and Gamewell- Dimensions:41/2"H x 4"W x 1 1/4" specified in this document.In some cases,certain FCI°are registered trademarks (11.4 x 10.2 x 3.2 cm) modules or applications may not be listed by certain of Honeywell International Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies,or listing may be in process.Consult factory for latest listing status. UL°is a registered trademark This system meets NFPA requirements for operation at 0 of Underwriter's Laboratories —49°C/32—120°F and at a relative humidity 93% 2% UL:S1913 Inc. RH(noncondensing)at 32°C 21C(90°F 319. FM:3023594 However,the useful life of the system's standby batteries M EA FDNY:219-02-E Vol.VI This document is not intended and the electronic components maybe adversely affected CSFM:7300-1703:0102 to be used for installation by extreme temperature ranges and humidity. Therefore, purposes.We tryto keep our ISO 9001 Certification product information up-to- it is recommended that this system and its peripherals be date and accurate.We cannot installed in an environment with a normal room coverall specific applications temperature of 15—271C/60—80°F. or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Ga mewell-FCI's Velociti Series°AOM-2RF and other products available by visiting www.Gameweit-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0625 1 H 108/18 H o n eywe I I www.honeywell.com ©2018 Honeywell International Inc. NEW INTERIOR OCCUPANT NOTIFICATION DEVICES SYSTEM -f SENSOR° i �.y F L-Series and L-Series with LED Indoor Selectable F I F I R R Horns, Strobes and E E Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. -- Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter(DVM)diagnostic test points for Horn strobes,and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics. LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15,30,75,95, wall or ceiling mount,standard or compact sizes, red or white color 115, 150,and 177 choices, bezel kits for alternate markings and languages,and LED • Rotary switches for candela,tone and volume selections color lenses for distinctive visual signaling. In addition,installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela,tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert,SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify • Synchronization through use of LIL approved power supplies that installation.All devices feature plug-in designs with minimal intrusion support System Sensor Sync protocol or System Sensor MDL3 into the back box,making installations fast and foolproof while Sync Module virtually eliminating costly and time-consuming ground faults.The • Horns,Strobes and Horn Strobes listed for wall or ceiling use universal mounting plate includes an onboard shorting spring,so installers can test wiring continuity before the device is installed. In addition,the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without SIGNALING SIGNALING removing the appliance from the wall or ceiling.The DVM test points F M ti are discreetly located on the face of the notification appliance which COU5 LISTED LISTED LISTED APPROVED enable faster troubleshooting and end of line(EOL)voltage checks Horn Strobes Horns: Horns; 3057072 7300-1653:0525 while greatly reducing the risk of misplacing or damaging appliances and Strobes: 54011 S4011 FM23FPUS0195 7135-1653:0503 55512,54011 7135-1653:0526 during troubleshooting. AVDS916-01•10/03/2023•Page 1 L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage,LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage,Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range,LED Strobes and Horn Strobes 16 to 33 V(24 V nominal) Operating Voltage Range,Horns 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UUULC Current Draw Data, Horn Tones, and Sound Output Data UIJULC Maxmimurn Strobe Current Draw(mA) UUULC Maxmimum Horn Current Draw(mA RMS) Candela 16-33 Volts 8-17.5 Volts 16-33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 95 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 — 110 3.1 KHz Non-Temporal Low 28 29 54 177 115 Coded High 43 47 54 185 120 — 3.1 KHz Coded High 42 43 54 UUULC Maximum Horn Strobe Current Draw(mA)and Sound • .: Current Draw(mA RMS),Horn Strobe, Sound Candela Range(15-185 cd) Output (d BA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVDS916-01•10/03/2023•Page 2 L-Series with LED Dimensions:Wall-Mounted Equipment 2.07" (63 mm) -� 3.46" 3.46" 1.25' m 88 mm 1.2 3.57" 1 88 mm 32 mm (9.1 cm) (3.9 c cm) (31.8 mm) no °• 00o• 5.38"5.27' o00o Oo00000o0o0op133.9 mm3..27" 3.7 cm)133.9014Y I I lei 2, L�® �� A0617-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Surface Mount Back Box for Wall for Walls(SBBGRL,SBBGWL) 2.07" 4.7" 1. 4.T' 1 B mm) 119 mm 32 mm (424 ) 1.85" 119 mm 1.25" 14.8" (4.69 cm) 06°0°0°0°0010 a�o LIP 00000•.°oo. •d0°a oo 00000°o°a°o •o a o•4 a 00000 004004 144 5.mm aoo 0 0 5.67' .a.o. r .o.o.o0 5.78" O 1.mm oa0000o0�00 (14.68 CM)00000000000 ° o0000000000 1® ®® A0613-00 A0549-00 A0554-01 Strobes,Horn Strobes Horn Surface Mount Back Box for Walls for Walls(SBBRUSBBWL) L-Series with LED Dimensions: Ceiling-Mounted Equipment 2.07" 6.92"diam. 2.5' (52.6 mm) (175.77 mm) (64 mm) 6.83"diam. 1.25" (173.5 mm) (31.8 mm) O O o C= o- O C=) 0 0 0 ® o o Q o 0 o 0 A0608-00 A0546-00 Strobes and Horn Strobes Surface Mount Back Box for Ceilings for Ceilings(SBBCRL,SBCWL) AVDS916-01•10/03/2023•Page 3 L-Series with LED: Ordering Information Model Description Model Description L-Series with LED Horn Strobes LED Lenses P21FILED 2-Wire,Horn Strobe,Wall,Red LENS-A3 Lens LED Amber Wall/Ceiling P2RLED-B 2-Wire,Horn Strobe,Wall,Red,Bilingual LENS-133 Lens LED Blue Wall/Ceiling P2WLED 2-Wire,Horn Strobe,Wall,White LENS-133 Lens LED Green Wall/Ceiling P2WLED-B 2-Wire,Horn Strobe,Wall,White,Bilingual LENS-R3 Lens LED Red Wall/Ceiling P2GRLED 2-Wire,Compact Horn Strobe,Wall,Red Accessories P2GRLED-B 2-Wire,Compact Horn Strobe,Wall,Red,Bilingual TR-2 Universal Wall Trim Ring Red P2GWLED 2-Wire,Compact Horn Strobe,Wall,White TR-2W Universal Wall Trim Ring White P2GWLED-B 2-Wire,Compact Horn Strobe,Wall,White, SBBWL Wall Surface Mount Back Box,Red Bilingual SBBWL Wall Surface Mount Back Box,White P2RLED-P 2-Wire,Horn Strobe,Wall,Red,Plain SBBGRL Compact Wall Surface Mount Back Box,Red P2WLED-P 2-Wire,Horn Strobe,Wall,White,Plain SBBGWL Compact Wall Surface Mount Back Box,White P2RLED-SP 2-Wire,Horn Strobe,Wall,Red,FUEGO TRC-2 Universal Ceiling Trim Ring,Red P2WLED-SP 2-Wire,Horn Strobe,Wall,White,FUEGO TRC-2W Universal Ceiling Trim Ring,White PC2RLED 2-Wire,Horn Strobe,Ceiling,Red SBBGRL Ceiling Surface Mount Back Box,Red PC2RLED-B 2-Wire,Horn Strobe,Ceiling,Red,Bilingual SBBCWL Ceiling Surface Mount Back Box,White PC2WLED 2-Wire,Horn Strobe,Ceiling,White Bezelst PC2WLED-B 2-Wire,Horn Strobe,Ceiling,White,Bilingual BZR Wall Red Bezel Kit L-Series with LED Strobes BZW Wall White Bezel Kit SRLED Strobe,Wall,Red BZGR Compact Wall Red Bezel Kit SRLED-B Strobe,Wall,Red,Bilingual BZGW Compact Wall White Bezel Kit SWLED Strobe,Wall,White BZRC Horn Strobe Ceiling Red Bezel Kit SWLED-B Strobe,Wall,White,Bilingual BZWC Horn Strobe Ceiling White Bezel Kit SGRLED Strobe,Compact,Wall,Red SGRLED-B Strobe,Compact,Wall,Red,Bilingual Notes for L-Series With LED Horn Strobes and Strobes: SGWLED Strobe,Compact,Wall,White All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. SGWLED-B Strobe,Compact,Wall,White,Bilingual All-ALERT models have"ALERT'marking on cover. SRLED-P Strobe,Wall,Red,Plain All-B models have"FIRE/FEU"marking on cover for use in Canadian SWLED-P Strobe,Wall,White,Plain applications. SRLED-SP Strobe,Wall,Red,FUEGO Amber lenses are not for use in Canadian applications SWLED-CLR- Strobe,Wall,White,ALERT Notes for L-Series Horns: ALERT *Horn-only models are listed for wall or ceiling use. SWLED-ALERT Strobe,Wall,White,ALERT,Amber Lens SCRLED Strobe,Ceiling,Red Notes for Bezels: SCRLED-B Strobe,Ceiling,Red,Bilingual tEach bezel pack ships in a package of 5. Add one of the following extensions for print/language options:-F(FIRE),-AL SCRLED-P Strobe,Ceiling,White,Plain (ALERT),-EV(EVAC),-AG(AGENT),-P(Plain),-FR(FEU),-PG(FOGO),-SP SCWLED Strobe,Ceiling,White (FUEGO),-SPE(FUEGO/FIRE). SCWLED-B Strobe,Ceiling,White,Bilingual SCWLED-P Strobe,Ceiling,White,Plain SCWLED-CLR- Strobe,Ceiling,White,ALERT ALERT L-Series Horns HRL* Horn,Red HRLA* Horn,Red,Plain, ULC HWL* Horn,White HWLA* Horn,White,Plain,ULC HGRL* Compact Horn,Red HGRLA* Compact Horn,Red,Plain,ULC HGWL* Compact Horn,White HGWLA* Compact Horn,White,Plain,ULC 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. www.systemsensor.com SYSTEM 3333 Unity Drive, Mississauga,ON L5L 3S6 Canada ©2023 System Sensor. Phone:800 SENSOR2•Fax:905 812-0771 Product specifications subject to change without notice.visit systemsensorcom SENSOR w or current product information,including the latest version of this data sheet. www.systemsensor.ca AVDS916-01.10/03/2023 NEW EXTERIOR OCCUPANT NOTIFICATION DEVICE SYSTEM SENSOR° L-Series Outdoor Horns and L-Series with LED Outdoor Quo Strobes and Horn Strobes System Sensor L-Series and L-Series with LED Outdoor ,I audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series Outdoor and L-Series with LED Outdoor platforms offer the most versatile and easy-to-use • Weatherproof per NEMA 4X, IP56 as a standalone device line of Weatherproof Horns, Horn Strobes,and Strobes that can meet • Rated from—40°F to 151°F virtually any application requirement, including indoor,outdoor,wet, • Electrically compatible with Legacy SpectrAlert Advance and dry,and washdown environment applications in temperatures from SpectrAlert devices at 16-33 VDC —40oF to 151°F. • Field-selectable candela settings on wall units: 15, 30, 75, 95, The L-Series Outdoor and L-Series with LED Outdoor appliances 110, 135,and 185 are NEMA 4X and IP56 rated without having to seal the backbox. • Field-selectable candela settings on celiling units: 15,30,75,95, Additional caulk or sealant are not required on the backbox for a 115, 150,and 177 faster,cleaner installation.The L-Series platform offers a modern aesthetic across the Indoor and Outdoor platform and design • Rotary switches for candela,horn,and volume variations across applications:wall or ceiling mount,red or white • Mounting plates with wirenuts are provided to make the color choices,LED colored lenses for distinctive visual signaling. connection between the field wiring and the mounting plates In addition, installers can easily adjust appliances through field • Synchronization through use of UL approved power supplies selectable candela,tone,and volume selections using rotary that support System Sensor Sync or System Sensor MDL Sync switches. Module LED technology offers significantly lower current draw compared • Tamper-resistant construction to older Xenon bulbs across a full candela range.This improves • Listed for ceiling or wall mounting design flexibility for notification appliance circuits(NACs)while also • Compact size for Wall Mount reducing power supply requirements allowing for simpler and lower cost installations. UL listed waterproof wirenuts are provided to make the connection between the field wiring and the mounting plates. Outdoor devices ship with plastic back boxes that accommodate in-and-out wiring for daisy chaining devices. Knock-outs located Agency Listings on the back eliminate the need to drill holes for screw-in mounting. SIGNALING Note: When replacing SpectrAlert Advance products,the backbox C UL US should be updated to the L-Series with LED backbox. F M om USTEI) APPROVED Horns:S4011 3057072 7125-1653:0537 Horn Strobes and Strobes: FM23FPUS0195 7300-1653:0536 S4011,S5512 7125-1653:0535 7135-1653:0534 AVDS-62173:A•08/29/2024•Page 1 Product Specifications Physical/Electrical Specifications Standard Operating Temperature -40oF to 151°F(-40oC to 66°C) Humidity Range 0 to 95 5% Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 24 VDC Operating Voltage Range 16 to 33 V(24 V nominal) Wiring between Fire Alarm Control Panel(FACP)and weatherproof 12 to 18 AWG back plate Environmental Considerations Devices meet rating requirements for NEMA 4X,Type 4X,and IP56 as a standalone device Wall Strobes and Horn Strobes(including lens) 5.84"L 3.76"W x 1.56"D(148mm x 95.5mm x 39.6mm) Wall Strobes and Horn Strobes(including lens)with SBBGRUWL 5.84"L x 3.76"W x 3.72"D(148mm x 95.5mm x 94.5mm) Surface Mount Back Box Ceiling Strobes and Horn Strobes(including lens) 6.8"diameter x 2.22"D(173mm x 56.4mm) Ceiling Strobes and Horn Strobes(including lens)with SBBCRU 6.98"diameter x 4.72"D(177.3mm x 120mm) WL Surface Mount Back Box Wall Horns 5.84"L x 3.76"W x 1.56"D(148mm x 95.5mm x 39.6mm) Wall Horns with SBBGRUWL Surface Mount Back Box 5.84"L x 3.76"W x 3.11"D(148mm x 95.5mm x 79mm) NOTE:SBBGRLM/L Surface Mount Back box intended for horns,horn strobes,and strobes. UUULC Maximum Strobe Current Draw(mA) UUULC Maximum Horn Current Draw(mA RMS) KV_W4 M�_ � ULIULC Maximum Horn Current Draw(mA)and Sound • .: • Current Draw Sound Candela Rating 16 to 33 Volts DC (mA RMS), Output 15 18 Horn (dBA) 30 22 Volume 16-33 16-33 75 70 Pos Sound pattern Setting(dB) Volts Volts 95 75 DC DC 110 85 1 Temporal High 35 85 115 90 2 Temporal Low 35 77 135 105 3 Non-Temporal High 50 85 150 110 4 Non-Temporal Low 35 77 177 115 5 3.1 KHz Temporal High 35 82 185 120 6 3.1 KHz Temporal Low 35 75 FCP" (future) 7 3.1 KHz Non-Temporal High 40 82 "FCP Fire Control Panel,future use 8 3.1 KHz Non-Temporal Low 35 75 UUULC Maximum Horn Strobe Current Draw(mA)and Sound • .: Sound Current Draw(mA RMS),Horn Strobe, Output Candela Range(15-185 cd) (dBA) 16-33 Volts 16-33 V Pos Tone Volume 15cd 30cd 75cd 95cd 110cd 115cd 135cd 150cd 177cd 185cd DC Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal High 35 38 87 92 94 120 189 189 190 190 85 2 Temporal Low 35 38 87 92 94 120 135 135 145 145 77 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 85 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 77 5 3.1 KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 82 6 3.1 KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 75 7 3.1 KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 82 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 75 AVDS-62173:A•08/29/2024•Page 2 L-Series with LED Outdoor Dimensions:Wall-Mounted Equipment ® o�a 0000000�ee000®00000�atv 0000000oaA0A000000°°° 000000000000A000000 ® o0 0 0 0 °0°0°0°0°0°0°0°0°0° 0000000000 ® oa��mmeo 0000000000000000000�° 0 00100�0101000 0000000000000000000 0000m�m�oe000a 000000000000000000g°�, 000u��a�o�T 000000°000000000005. 0000 00001 0°0°0°0°0°0°0°0°0°0°0 0 0�o� °a°o°o 0000000 0000000 $$0000°0�001003 ® ao °0 A0547-00 A0557-00 Outdoor Compact Wall Horn with Outdoor Compact Wall Horn with Compact Surface Mount Back Box(SBBGRUSBBGWL) Compact Surface Mount Back Box(SBBGRUSBBGWL) s,amm �aor� m ® o 00 0 0°00000@0009080°0°0� 0°O°0°0B°°°e°00000 m 000 o O 00°0°00 00 00000 A0613-00 A055v4-01 Outdoor Compact Strobes,Horn Strobes for Wall with Outdoor Compact Strobes,Horn Strobes for Wall with Compact Surface Mount Back Box(SBBGRUSBBGWL) Compact Surface Mount Back Box(SBBGRUSBBGWL) L-Series with LED Outdoor Dimensions: Ceiling-Mounted Equipment ® o O o � ® ®51R'm?• 0 O ® ® A0608-00 A0546-00 Strobes,Horn Strobes for Ceilings with Surface Strobes,Horn Strobes for Ceilings with Mount Back Box(SBBCRUSBBCWL) Surface Mount Back Box(SBBCRUSBBCWL) AVDS-62173:A•08/29/2024•Page 3 L-Series with LED Outdoor: Ordering Information Model Description Model Description L-Series with LED Outdoor Horn Strobes LED Lenses P2GRKLED 2-Wire,Compact Horn Strobe,Wall,Red LENS-A3 Lens LED Amber Wall/Ceiling P2GRKLED-P 2-Wire,Compact Horn Strobe,Wall,Red,Plain LENS-B3 Lens LED Blue Wall/Ceiling P2GRKLED-B 2-Wire,Compact Horn Strobe,Wall,Red,Bilingual LENS-G3 Lens LED Green Wall/Ceiling P2GWKLED 2-Wire,Compact Horn Strobe,Wall,White LENS-R3 Lens LED Red Wall/Ceiling P2GWKLED-P 2-Wire,Compact Horn Strobe,Wall,White,Plain Accessories P2GWKLED-B 2-Wire,Compact Horn Strobe,Wall,White, SBBGWL Compact Wall Surface Mount Back Box,Red Bilingual SBBGWL Compact Wall Surface Mount Back Box,White PC2RKLED 2-Wire,Horn Strobe,Ceiling,Red SBBCWL Ceiling Surface Mount Back Box,Red PC2RKLED-P 2-Wire,Horn Strobe,Ceiling,Red,Plain SBBCWL Ceiling Surface Mount Back Box,White PC2RKLED-B 2-Wire,Horn Strobe,Ceiling,Red,Bilingual PC2WKLED 2-Wire,Horn Strobe,Ceiling,White Notes for L-Series With LED Outdoor Horn Strobes and Strobes: All-P models have a plain housing(no"FIRE"marking on cover). PC2WKLED-P 2-Wire,Horn Strobe,Ceiling,White,Plain All-SP models have"FUEGO"marking on cover. PC2WKLED-B 2-Wire,Horn Strobe,Ceiling,White,Bilingual All-ALERT models have"ALERT'marking on cover. L-Series with LED Outdoor Strobes All-B models have"FIRE/FEU"marking on cover for use in Canadian SGRKLED Compact Strobe,Wall,Red applications. SGRKLED-P Compact Strobe,Wall,Red,Plain SGRKLED-B Compact Strobe,Wall,Red,Bilingual SGWKLED Compact Strobe,Wall,White SGWKLED-P Compact Strobe,Wall,White,Plain SGWKLED-B Compact Strobe,Wall,White,Bilingual SCRKLED Strobe,Ceiling,Red SCRKLED-P Strobe,Ceiling,Red,Plain SCRKLED-B Strobe,Ceiling,Red,Bilingual SCWKLED Strobe,Ceiling,White SGWKLED-P Strobe,Ceiling,White,Plain SCWKLED-B Strobe,Ceiling,White,Bilingual L-Series Outdoor Horns HGRKL Compact Horn,Red HGRKL-B Compact Horn,Red,Bilingual 3825 Ohio Avenue•St.Charles, IL 60174 USA System Sensor®is a registered trademark Phone:800-SENSOR2•Fax:630-377-6495 of Honeywell International,Inc. www.systemsensor.com SYSTEM 3333 Unity Drive, Mississauga,ON L5L 3S6 Canada ©2024 System Sensor. Phone:800 SENSOR2•Fax:905 812-0771 Product specifications subject to change without notice.Visit systemsensorcom SENSOR w or current product information,including the latest version of this data sheet. www.systemsensor.ca AVDS-62173:A•08i29i2024 NEW FIRE ALARM TERMINAL CABINET Installation Instructions SPACE AGE ELECTRONICS , INC. TC2-32 Installation and wiring should be performed by qualified personnel only- Equipment damage and/or 14" malfunction may result from improper installation. 'C Remove all power from the system until the installation is complete and ready for testing. All work of any kind shall be performed to meet the FIRE requirements of any and all local, state and federal ALARM codes and/or standards set by the authority having 14" 0 TERMINAL jurisdiction. CABIN o Installation Procedure • Remove lift-away cover from back box and set aside. 3 • Place back box on wall where it is to be mounted and mark the location of holes to Power-Limited Wirin mount box to the wall. • Drill appropriate size holes in wall for 0 appropriate mounting screws being used, (screws not supplied). • Mount back box to wall with appropriate hardware (not supplied). ° • Replace cover onto unit. 1 2 1 2 8 8 , 1 O 5 4 Z 2 8 8 °' Equipment Supplied 7 5 5 8 8 8 8 9 y � •(1) Cover W/labeling for terminal strips 13 11 0 4 4 12 1 2 •(1) Back box W/ (2) 16 point terminal points 5 1J 1 6 15 15 16 1 •(1) Installation Instructions 6 Removable formed lift-a-way hinge Nonpower-Limited Wiring q * UL Power-Limited Wiring Requirements: Power-Limited and nonpower-limited circuit wiring must remain separated inthe cabinet. All power-limited circuit wiring must remain at least 0.25" away from nonpower-limited wiring. Furthermore, all power-limited circuit wiring and nonpower- Terminal Point Identification Labels` limited wiring must enter and exit the cabinet through different knockouts and/or 12 Gauge Ground Strap Assembly conduits. 20 amps maximum. Door to Back Box Ordering Information: Part # Description SS000645 TC2-32 32 Point Terminal Cabinet Space Age Electronics, Inc. ©Space Age Electronics, Inc. 2007 www.1sae.com - voice ECO247 LT10304 Rev. B Pg. 1/1 508.485.4740 - fax l - C 1 • C • " • R•. S i W 11MAIII.ithin.and J BW-DocBox BW-DocBox (15"W x 13"H x 4"D) includes: • Three labels: _ "Fire Alarm Documents" "As-Built Permits" "Test and Maintenance Documents" • An adjustable bungee allows you to fit various sizes of binders, • '• documents, smoke-cans, etc. • A door bracket holds two CDs, three sets of keys and more documents • A cam lock with two keys own 113W-DocBox2 (11"W x 15"H x 4"D) . Smaller and more basic model without the door bracket for CDs and key sets. However, it does have the three labels, adjustable bungee and a lock with two keys. on't see the box you wa Customization, special colors, and/or silk-screening of logos are all us or visit our websit available for quantities of 25 or more. (requires lead time) WRi er DUCTS, INC. 800-473-0213 E-mail: info C-'mierproducts.com FIRE PROTECTION, INC. PO BON 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX 14251353-4546 April 15,2025 Attn : CITY OF ARLINGTON FIRE PREVENTION RE: FULL FIRE ALARM SYSTEM UPGRADE INSTALLATION SCOPE OF WORK: A FULL FIRE ALARM SYSTEM UPGRADE INSTALLATION IN A NON-SPRINKLED THREE-STORY MEDICAL BUILDING. THE INSTALLATION INCLUDES A NEW FIRE ALARM CONTROL PANEL, NEW REMOTE POWER SUPPLIES, NEW OCCUPANT NOTIFICATION DEVICES AND NEW INITIATING DEVICES. INITIATING DEVICES ARE FOR ELEVATOR RECALL AND, MANUAL PULL STATIONS AT EACH EXIT OF EACH FLOOR AND EACH EXIT FROM THE BUILDING. THE FIRE ALARM CONTROL PANEL AND REMOTE POWER SUPPLIES WILL BE LOCATED IN THE JANITORIAL CLOSET IN THE FIRST FLOOR HALLWAY. ALL OLD DEVICES TO BE REMOVED AND EXISTING FIRE ALARM BOXES NOT BEING USED WILL BE BLANK PLATED. ALL EXISTING WIRING NOT BEING USED WILL BE REMOVED. FOR THE MANUAL PULL STATION AND ANNUNCIATOR LOCATED AT THE MAIN ENTRY OF THE BUILDING, WIREMOLD WILL BE USED TO PROTECT THE WIRING GOING AROUND THE ALCOVE GETTING THE WIRE WHERE IT NEEDS TO BE. FIRE ALARM DEVICES QUANTITIES ARE AS FOLLOWS : (1) FIRE ALARM CONTROL PANEL, (2) REMOTE POWER SUPPLIES, (1) REMOTE ANNUNCIATOR, (1) AES 2.0 RADIO, (5) SMOKE DETECTORS, (7) MANUAL PULL-STATIONS, (3) ADDRESSABLE RELAY MODULES FOR ELEVATOR RECALL, (45) CEILING MOUNTED HORN-STROBES, (62) CEILING-MOUNTED STROBE ONLY. THE SYSTEM SHALL BE 100% PRE-TESTED AND ALL ELECTRICAL FINALS COMPLETED PRIOR TO REQUESTING THE FIRE FINAL INSPECTION. INSTALLATION COMPANY Fire Protection, Inc. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 WSCL# FIREPI*021ML UL CERT #608242-002 SITE ADDRESS CUMULUS PARK HEALTH 16410 SMOKEY POINT BLVD ARLINGTON, WA 98223 APPROVED UL MONITORING COMPANY SECURITAS / FPI CONTRACTUAL RESPONSIBLE PARTIES Installation Fire Protection, Inc. Should you have any further questions, please feel free to contact me directly. NICK CHANDLER, AET NICET-III #148121 SYSTEMS ENGINEER/DESIGNER L CUMULUS PARK HEALTH ynnwood,WPROTECTION/NC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 www.fpiseattle.com FIRE ALARM FULL SYSTEM UPGRADE Pot. SEQUENCE OF OPERATIONS EQUIPMENT LEGEND SHEET INDEX 000805173 SYSTEM OUTPUTS FA 0.0 FIRE ALARM-PROJECT DETAILS ROY L CATS Required Fire Safe Control w SYTvEOL Q17ANIilY NI4TTJFACRJREIG PART NO IRS(a2IP7TON FA 1.0 FIRE ALARM-FIRST FLOOR PLAN,EXISTING DEVICE LOCATIONS&CEILING PLAN QIC,I? CTjO�, Central Supervising Stallon a FA 2.0 FIRE ALARM-SECOND FLOOR PLAN,EXISTING DEVICE LOCATIONS&CEILING PLAN Control Unit Annunciation ,0 FA 3.0 FIRE ALARM-THIRD FLOOR PLAN,EXISTING DEVICE LOCATIONS&CEILING PLAN In 1 GANEWELLFLT GWF-7075 INIELDGEWFIRE ALARMOONIROLPANEL RED LL n FA 4.0 FIRE ALARM-BATTERY CALCULATIONS&SINGLE LINE RISER DIAGRAM �'y NFPA .0 mC ,ee FA 5.0 FIRE ALARM-VOLTAGE DROP CALCULATIONS �J CFPS yy I ADS 7707P-88-UIP-M ULIISTED VORELESS RADIO FIRE AIARMCONFAWAIUR PROJECT SCOPE LETTER #1473 y= r (P ® 2 HONEYWF,[L HPF-PS6 6-ANP,74-WLTPOWMSUPPLY SCOPE OF WORK: ti =QQ I GANEWEILFCI RA-10DOR REMJIEA1 NU I IORFORLSEWMGwF-7075,RED A FULL FIRE ALARM SYSTEM UPGRADE INSTALLATION IN A NON-SPRINKLED THREE-STORY MEDICAL BUILDING. i I? m� °� FA4 THE INSTALLATION INCLUDES A NEW FIRE ALARM CONTROL PANEL,NEW REMOTE POWER SUPPLIES,NEW �Q m I GANEWEILFCI 586QIR REDTRIMRING FOR SURFACE NDUNIING OCCUPANT NOTIFICATION DEVICES AND NEW INITIATING DEVICES.INITIATING DEVICES ARE FOR ELEVATOR RECALL AND,MANUAL PULL STATIONS AT EACH EXIT OF EACH FLOOR AND EACH EXIT FROM THE BUILDING.THE FIRE �_w °w Q t,° a a•w e y ALARM CONTROL PANEL AND REMOTE POWER SUPPLIES WILL BE LOCATED IN THE JANITORIAL CLOSET IN THE u> > i i t Q OS 5 GANEWEILFC1 ASO PL3 W/B3006 PHOTOEIEC'n+R'SNDKE DETECTOR BRIGHrWHfI$4ELOCTIIW/6'FIATYEDNDUTrMEASE,MIGEPWHf1E -- u FIRST FLOOR HALLWAY. Q H Z K 7 GANEwE[LFCI NE-7ASF vELOCMAECRESSARIESPr EACUONSTATaN ALL OLD DEVICES TO BE REMOVED AND EXISTING FIRE ALARM BOXES NOT BEING USED WILL BE BLANK w 3 V W eF eF ym`m`m`m ym ❑F PLATED.ALL EXISTING WIRING NOT BEING USED WILL BE REMOVED. o ii�o I GAVEWELLFC1 SETO SURFACENDUNFBOCKBOXFORNS SERIFS PULLSTATIONS,PIASTIC FOR THE MANUAL PULL STATION AND ANNUNCIATOR LOCATED AT THE MAIN ENTRY OF THE BUILDING, SYSTEM INPUTS A B C D E F G H I 3 GANEWELLFQ AONF2RF ADDRESSABLE REIAYNDIXIIE W/FIASI-SCAN,2 FORMC IRYCONFACIS U o 0 6 WIREMOLD WILL BE USED TO PROTECT THE WIRING GOING AROUND THE ALCOVE GETTING THE WIRE WHERE IT Z y y 1u M W 1 Manual Fire Alarm Pull-Station 2 FACP Smoke Detector ♦ ♦ ♦♦ 2 NEEDS TO BE. y c c LL< o m W W W H 45 SYSIEMSEFSOR PC2WIID HORNSTROBE,CEILING,WHITE Z 3 w > 3 tat Floor Elevator Lobby Smoke ♦ ♦ ♦ ♦♦ 3 ;0 w a o POWER a>>a-o > Q 4 2nd Floor Elevator Lobby Smoke ♦ ♦ ♦ ♦♦ 4 SUPPLIES,(1)REMOTE ANNUNCIATOR,(1)AES 2.0 RADIO,(5)SMOKE DETECTORS,(7)MANUAL PULL-STATIONS,(3) o it it H m a o 5 3rd Floor Elevator Lobby Smoke ♦ ♦ ♦ ♦♦ 5 67 SSSTEMSENSOR SCWIED STROBE,CERAG,WHLIE ADDRESSABLE RELAY MODULES FOR ELEVATOR RECALL,(45)CEILING MOUNTED HORN-STROBES,(62) REVISION RECORD 6 tat Floor Elevator Mach Rm Smoke ♦ ♦ ♦♦♦♦ 6 CEILING-MOUNTED STROBE ONLY. DESCRIPTION CL 7 Unused 7 1 TYSTEMSEFSOR P2GRI(IM 2-WmEFDRNSTROBE,STANDARDCD,RED,OUTDOOR DATE/ ul 8 Unused 8 THE SYSTEM SHALL BE 100%PRE-TESTED AND ALL ELECTRICAL FINALS COMPLETED PRIOR TO REQUESTING 9 Fire Alarm AC Power Failure ♦ ♦ jl enTc I SPACE#IE SSLIM645 TC2-3232 POTNrFIRE A[ARMTIR2MNALCABINEr THE FIRE FINAL INSPECTION. M10 Fire Alarm System Low Battery ♦ ♦11 Open Circuit ♦ ♦ ® I THEDDCBDX BWrDOCBDX FIRE AIARNIDOCU ENFBOX 12 Ground Fault ♦ ♦ PROJECT CODE INFO A 2 DURACEIL. 12WC,8AA BATIERIF_S FORFIREAIARMCONIROLPANEL a DORA= I2WC,8AH BATIERIES FORREENDIE POWER SUPPLIES AUTHORITY HAVING JURISDICTION:CITY OF ARLINGTON 1 DURACE L 12WC,12AH BATIERYFOR AFS RADIO DEVICE INSTALLATION REQUIREMENTS APPLICABLE BUILDING CODE:2021 INTERNATIONAL BUILDING CODE APPLICABLE FIRE CODE:2021 INTERNATIONAL FIRE CODE NOTPERNII'fID SITE PLAN APPLICABLE ELECTRICAL CODE:2023 NATIONAL ELECTRICAL CODE SUPPORT HERE4 BRACKET �. DIFFUSER STANDARDS:2022 NFPA 72,CITY OF ARLINGTON l-Box cIRro A TENANT USE AND OCCUPANCY: AMBULATORY CARE FACILITY(B) VVV Ill\\\ FADEVTCE CEHM SNDRE CLASSIFICATION OF SUPERVISING STATION:REMOTE SUPERVISING STATION DETF.CIOR ylll y„ nt>n13' REMOTE SUPERVISING STATION:SECURITAS,LACEY WA AWAYFROM NOTPERNII'fID 12" FmxlxFFtams HERE UL LISTED PRIME FIRE ALARM CONTRACTOR:FIRE PROTECTION INC HIS SNDKE PARCEL NUMBERS:31052900100800 166TH PL NE PROJECT CONTACT INFO NMH1EG[992"AF.F NWHEICR3r82"ARF !Alm BUILDING OWNER FIRE ALARM CONTRACTOR 713 SMOKEY POINT PROF GROUP LLP FIRE PROTECTION,INC. FAA 1505 E 5TH ST 17410 ASH WAY,Ste 8 ARLINGTON,WA 98223 LYNNWOOD,WA 98037 FACP \ CONTACT:DALE DUSKIN CONTACT:DAVID MOW 66" F.F W. .FPULL ----- PHONE:425.239.5074 PHONE:425.290.9600 ------ �.� DALE.DUSKI N@ME.COM NICK@FPISEATTLE.COM INSTALLATION KEY NOTES i --------F14SHEDFLOOR ( FIRE ALARM CONTROL PANEL.NEEDS DEDICATED 120VAC CIRCUIT. INSTALLATION NOTES r/�r J (2) REMOTE POWER SUPPLY.NEEDS DEDICATED 120VAC CIRCUIT,CAN SHARE WITH THE FACP. r f-)l� m ® WIRELESS FIRE ALARM AES 2.0 COMMUNICATOR.NEEDS DEDICATED 120VAC OUTLET,CAN SHARE WITH THE FACP. H Z REMOTE FIRE ALARM ANNUNCIATOR. 1. THESE DRAWINGS ARE DIAGRAMMATIC.INSTALLATION SHALL COMPLY WITH NEC,NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. a (3) TRIM RING FOR REMOTE FIRE ALARM ANNUNCIATOR TO ALLOW FOR WIREMOLD. 2. CABLE ROUTING SHOWN ON DRAWINGS IS FOR INTENT.EXACT ROUTING TO BE COORDINATED WITH OTHER TRADES IN THE FIELD.SEE j (3) SURFACE MOUNT BACK BOX FOR MANUAL PULL STATION TO ALLOW FOR WIREMOLD. SPECIFICATIONS AND DRAWING NOTES FOR ACCEPTABLE INSTALLATION METHODS.ALL WIRING ABOVE T SHALL BE FREE-FLY UNLESS `L O ADDRESSABLE RELAY FOR ELEVATOR RECALL.COORDINATE CONNECTIONS REQUIRED BY CODE. O -- ® INSTALLATION OF WIREMOLD TO PROVIDE A CLEAN PATHWAY IN THE MAIN ENTRY ALCOVE FOR ANNUNCIATOR AND 3. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC-ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS.WIRING SHALL BE W MANUAL PULL STATION. PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS.THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME D R City of Arlington RACEWAY. Building Department DATE: 04.09.2025 H N/STROBE 9 p VICINITY MAP 4. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. APPROVED 5. POWER FOR ALL FIRE ALARM PANELS,REMOTE AMPLIFIERS AND REMOTE POWER SUPPLIES MUST BE PROVIDED BY A DEDICATED ,,I .I 120VAC BRANCH CIRCUIT.THE LOCATION OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE FACP, Kevin Olander-05/0 1/2025 MECHANICALLY PROTECTED,ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL AND SHALL BE RED AND LABELED"FIRE ALARM CIRCUIT CONTROL"IN ACCORDANCE WITH NFPA72. NO changes authorized Unless approved by Ketchum 6. POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET.ALL POWER-LIMITED CIRCUIT the Building Official = M WIRING MUST REMAIN AT LEAST 0.25"AWAY FROM ANY NON-POWER LIMITED CIRCUIT WIRING.FURTHERMORE,ALL POWER-LIMITED AND NON-POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATEINN J m 04 CONDUITS. N Stanwood Q 7. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. __ _ W Z (7) CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR.CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS,BOXES, = Q ENCLOSURES,FIRE ALARM DEVICES,OR UTILIZATION EQUIPMENT.WHERE INSTALLED EXPOSED,CABLES SHALL BE ADEQUATELY Y d SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY BUILDING IY CONSTRUCTION.WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR,IT SHALL BE RUN IN RACEWAY. Arlington Q > Z 7. MANUAL PULL-STATIONS:SHALL BE LOCATED WITHIN 5'OF EACH EXIT DOORWAY.THE OPERABLE PART OF A MANUALLY ACTUATED ILY 0 ALARM-INITIATING DEVICE SHALL NOT BE LESS THAN 42"AND NOT MORE THAN 48"ABOVE THE FINISHED FLOOR.MANUAL Q PULL-STATIONS SHALL BE UNOBSTRUCTED AND ACCESSIBLE. Z 8. SMOKE DETECTORS INSTALLED IN THE CORRIDORS ARE TO BE SPACED AT 21.5'x41'PER 2016 NFPA-72 17.6.3.1.1(H)&17.7.3.2.4.2(4). Kayak J:3 9 0 Z 2ABBREVIATIONS USED IN THE DRAWINGS (1) SMOKE DETECTORS MUST BE INSTALLED A MINIMUM OF Y FROM MECHANICAL DIFFUSERS.CENTER SMOKE DETECTORS IN CORRIDORS Point 16410_Sm_okey Point 2 CD WITH CEILING LIGHTING WHEN POSSIBLE. - - - - - - � r Q 9. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS 100%COMPLETED(MOVE-IN READY). 'Blvd,Arlington, Canyon L) coo AFF ABOVE FINISHED FLOOR GWB GYPSUM WALL BOARD WA 48223 Creek 10. WALL MOUNTED STROBES SHALL BE PLACED 80"MINIMUM TO 96"MAXIMUM ABOVE FLOOR LEVEL.(NFPA72 18.5.4.1&2).WALL MOUNTED Ah AMP HOUR HVAC HEATING VENTILATION AIR CONDITIONING STROBES SHALL BE SIZED IN ACCORDANCE WITH(NFPA72 TABLE 18.5.4.3.1(A). AHJ AUTHORITY HAVING JURISDICTION IBC INTERNATIONAL BUILDING CODE 1 I 11. CEILING MOUNTED STROBES SHALL BE PLACED AND SIZED IN ACCORDANCE WITH(NFPA-72 TABLE 18.5.4.3.1(B). AHU AIR HANDLING UNIT IFC INTERNATIONAL FIRE CODE I AIM ADDRESSABLE INPUT MODULE L# SLC LOOP NUMBER 12. WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME WHETHER THEY ARE IN THE SAME ROOM OR cd CANDELA M MODULE(ADDRESSABLE) I Marysville ADJACENT SPACE WITHIN THE FIELD OF VIEW,THE FLASH OF THOSE STROBES SHALL BE SYNCHRONIZED(NFPA-72,SECTION CO CARBON MONOXIDE M.C. MECHANICAL CONTRACTOR SHEET TITLE 18.5.4.3.2(3)&(4). CONT. CONTINUE N# NAC CIRCUIT NUMBER f D DEVICE(ADDRESSABLE) NEC NATIONAL ELECTRIC CODE - - - Lake 13. INSTRUCTIONS FOR THE OPERATING,TESTING AND MAINTENANCE OF THE SYSTEM,ALONG WITH RECORD DRAWINGS OTHERWISE DC DUAL CIRCUIT NFPA NATIONAL FIRE PROTECTION AGENCY FIRE ALARM REFERRED TO AS("AS-BUILT")AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM DOCUMENT CABINET NEXT TO THE DN DOWN RFDS REDMOND FIRE DEPARTMENT STANDARDS Stevens PROJECT DETAILS FACP(NFPA-72 10.18.2.3). E.C. ELECTRICAL CONTRACTOR RIPS REMOTE POWER SUPPLY 14. PRIOR TO CALLING FOR INSPECTION,THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE SYSTEM EOL END OF LINE RESISTOR RR RESTROOM Everett HAS BEEN INSTALLED,TESTED,EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE EQUIP EQUIPMENT SPK SPEAKER APPROVED PLANS.THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN NFPA-72 RECORD OF COMPLETION(NFPA-72 10.18.2.1.1). EVAC EMERGENCY VOICE EVACUATION SLC SIGNALING LINE CIRCUIT THE COMPLETED RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ INSPECTOR PRIOR TO REQUESTING A FIRE FINAL FA FIRE ALARM STG STORAGE N SHEET NUMBER INSPECTION(NFPA-72 10.18.2.1.2.4).A FIRE ALARM ZONE MAP AND A CURRENT/VALID FAOP(FIRE ALARM OPERATIONAL PERMIT)SHALL FAA FIRE ALARM ANNUNCIATOR W WATTS BE POSTED AT THE FACP. FACP FIRE ALARM CONTROL PANEL WP WEATHER-PROOF G.C. GENERAL CONTRACTOR FA O.0 L7L'17 FIRE PROTECTION INC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 www.fpiseattle.com DEVICE IDENTIFICATION LEGEND IM;IA IA171 i 11;1161, CABLE AND NOTIFICATION DEVICES 1) FIRE ALARM CONTROL PANEL.NEEDS DEDICATED 120VAC CIRCUIT. 0 LINE TYPE LABEL CABLETYPE ARU RESIST(sue) DESCRIPTION 1,2-003 © REMOTE POWER SUPPLY.NEEDS DEDICATED 120VAC CIRCUIT,CAN SHARE WITH THE FACP.WIRE CIRCUIT Do (RPSI:NAC5)TO THE RPS's ONBOARD TROUBLE CONTACTS TO SUPERVISE FOR AC POWER/BATTERY FAULT NFPA A 142 FPLR 14 3.07 NCC:NOTIFICATION APPDANCECIRCUIT DEVICE NDNBER TROUBLE CONDITIONS.(SEE RPS INSTALLATION MANUAL) 000805173 NAC;CIRCUITNUNBER © WIRELESS FIRE ALARM AES 2.0 COMMUNICATOR.NEEDS DEDICATED 120VAC OUTLET,CAN SHARE WITH THE FACP. D 1614 PEER 16 4.87 DATA-A14SUNCLCOR CIRCUIT LL W CIRC[IlT ® REMOTE FIRE ALARM ANNUNCIATOR. ROY L CATS U IS@FPLR 18 7.77 SIC:SIGNALM LINE CIRCO[T © TRIM RING FOR REMOTE FIRE ALARM ANNUNCIATOR TO ALLOW FOR WIREMOLD. QPOTECli Z I8/2 FPIA IS 7.77 IOC:ANAIDGRVRIAIIIJGDEVICE CIRCUITADDRESSABLE DEVICES Q` °y ® SURFACE MOUNT BACK BOX FOR MANUAL PULL STATION TO ALLOW FOR WIREMOLD. 4 � N W � m Ll-D001 O ADDRESSABLE RELAY FOR ELEVATOR RECALL.COORDINATE CONNECTIONS All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS,PER THE REQUIREMENTS LLLT ��CE�ER (1) INSTALLATION OF WIREMOLD TO PROVIDE A CLEAN PATHWAY IN THE MAIN ENTRY ALCOVE FOR ANNUNCIATOR AND Yy� NFPA" 5 OF IBC,IFC,NPFA-72&NFPA-70(NEC) MANUAL PULL STATION WIRING. J DEVICE TYPE CEPS SLC CIRC NLA4Em 1) MOUNT OUTDOOR BELL TO BE SEEN BY INCOMING EMERGENCY VEHICLES. #1473 SLC CIRCUIT t0 NEW DOCUMENT CABINET. u# _ W F O 2V� K =W N W Q N=m K W if. 6 F Z2UN U• Sj Jrur 6J' yO�WNQ =mmrc:`O G _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ?�W W iG ❑ V 1 m W W W Q - - - - - - - - gawww•0o a 1 - - - -�-- EXAM EXAM EXAM O EXAM EXAM EXAM -�-- A ' G W 19 W ❑ 'I y-_N4 XA Vr- D EN FJI REVISION RECORD O ® RP ®]o RES Mo9 i OFFICE sI• -07 Re 1•M s i i DATE/DESCRIPTION RPS 1•M ® lRd F 1 - - - - - - — F H H — — - - - - - -� —- )FT 17L ICEPI - OFFICE RPS I•M.11 U RPS I•M-0S RPS I•M-06 I I P it � ® I MECI-1. i nil. wArr PRIETP EY-W SUITE]03 SURE 103 M]z AREA H RPS H RECEPTION 103 ST O STAFFRPs Eo a RPS 1,M-0 w RK Is Ism OFFIE OmCE A iffS l -03 RPS l•M•04 S 1•M-0Z ,A RPS M-0 EL EC. S Ek - F F 1 7C/S FIDfNi E - 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -�-- E enN�wssFoauro�sRnFt�FATC z - - - - -�-- IU S 102NDFL DN DN EXAM DN ® A L, DN .TAN. >�. \ ,�,1 > ^ S BCM'. WORK Jl $rc F STG.. St O - JI sm � $Tc. $� AREA UP UP RPS F H ` UP \ 1•M-02 RPmS I•M-0 `� UP H FA(T• ]0wiwT RPS 1•M 1 1 1 ISm OF110E I O O 0Jjj I A 2 S FFICE OFFICE OFFICE LAB s 7 FiEV. 15 \ FOP, ]SEV D• 01 ❑ ❑ — BLJILDU WORK OFFICE J FACP ID)� AREA m OFFI >N I FACP•M-07 � RPS t•NI•w H 3am RP 1•M•09 H H FACP•M-0I ISm _ _ _� F 5 FACP•M UP - 1 IS 1117 EXAM PREP O 0 OPIN 0 OFFICE b OPIN \' SUITE 107 RPS t•M TO r7 H4 FACP•M ISM � 11 °°` — —I— Ism— -I °°` — e e ®FAA 8 H RPS 1• 11 FACP•M-03 sm OFFICE AREA AREA SUITS 101 - - - - - - - - - - - - - - - -i- - - - - - - - - - - - - -- RPS I•M•12 EOL4O HOW VVP� DATE: 04.09.2025 2 � J J N m N LLIZrn _ — Q aWz Y O O J M Z M CO J M O W N LEVEL 1 SCALE:1/8"=1' City of Arlington SHEET TITLE Building Department APPROVED FIRE ALARM LEVEL 1 Kevin Olander- 05/01/2025 FLOOR PLAN No changes authorized unless approved by the Building Official SHEET NUMBER FA 1 .0 L7L'17 FIRE PROTECTION INC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 www.fpiseattle.com DEVICE IDENTIFICATION LEGEND TAUATIONK YNOMS ASILNOTIFICATION DEVICES O FIRE ALARM CONTROL PANEL.NEEDS DEDICATED 120VAC CIRCUIT. IDJE TiPE LABEL GABLE riPE AaG RESIST(EM) DESCRIPTION NL•003 ® REMOTE POWER SUPPLY.NEEDS DEDICATED 120VAC CIRCUIT,CAN SHARE WITH THE FACP.WIRE CIRCUIT (RPS1:NAC5)TO THE RPS's ONBOARD TROUBLE CONTACTS TO SUPERVISE FOR AC POWER/BATTERY FAULT moo A 1a2FPIR 14 3.07 NAC:AY)11FTCA170NAPPIIANCECIRCUrF DEMCENLA13FR TROUBLE CONDITIONS.(SEE RPS INSTALLATION MANUAL) NFPA --LLNAC CIR=NUIVBER ® WIRELESS FIRE ALARM AES 2.0 COMMUNICATOR.NEEDS DEDICATED 120VAC OUTLET,CAN SHARE WITH THE FACP. 000805173 D I6/4 FPIR 16 4.87 DATA:ANN[13CIA1DR CTRC[IIF NAC CIRCUIT O REMOTE FIRE ALARM ANNUNCIATOR. U 18/2 FPIR 18 7.77 SIC:SIGNALIN UNECIRCUIT © TRIM RING FOR REMOTE FIRE ALARM ANNUNCIATOR TO ALLOW FOR WIREMOLD. ROY L CATS ADDRESSABLE DEVICES ® SURFACE MOUNT BACK BOX FOR MANUAL PULL STATION TO ALLOW FOR WIREMOLD. QpOTECl7 z 182FPFR 18 7.77 mc:ANALocF�TtlAluacDEMcecmcGrr F, O L)•I001 O ADDRESSABLE RELAY FOR ELEVATOR RECALL.COORDINATE CONNECTIONS 4 Na All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS,PER THE REQUIREMENTS DEVICE NLA13ER ® INSTALLATION OF WIREMOLD TO PROVIDE A CLEAN PATHWAY IN THE MAIN ENTRY ALCOVE FOR ANNUNCIATOR AND OF IBC,IFC,NPFA-72 R NFPA-70(NEC) MANUAL PULL STATION WIRING. r 1141 LLL DEVICE.IYPE y NFPA" 5 SLC CIR=NUNBER MOUNT OUTDOOR BELL TO BE SEEN BY INCOMING EMERGENCY VEHICLES. d� CFPS y SLCCIRCUIT 0 NEW DOCUMENT CABINET. #1473 u# _ W F- O 2Va K F 2 W v W a N 2 m K W Ti F 6 F o°ao x 2f UN U' YO°W iva --__- �U - __ � � T j ) EXAM EXAM EXAIv] EXAM OMCF FxAM W W a ° R00r RPS2 1-01 RPS -NI-Z BPS 1-03 RPS-NP RP Iz•NI-09 1 1 cd IS IS RPSI•N3 3EOLa 15cd 15cd 15M 15cd t REVISION RECORD Iscd DATE DESCRIPTION �E a - - - - - ---— - - - - - - - - - - - - - - - — H H ; EXAM 1 RPS 1•Ni 12 RPS 2•NI-05 RPS 2 -08 15 15cd IScd Scd j RPS I•Ni• j RPS 2• 11 j 1 RPS 2•NI-06 H 15cd 15cdA SUITE 205 BPS 30W 2 N 111 H RPSt •10 15cd A RPS 2-t-07 _-- IS d IS 1 15cd RPS 1• i19 •N1.12 EX 15cd 1 15 H RPS l•NS-06 RPS2•N1.15EOL4.7k RP 2-NI 14 IS d IS d� 3A / _ 1 _ _ F _ _ _ _ _ _ ( C 6A N•+G FIRS FOR ZND&3RDFIs F F RPS 1.13 �/ 1 - - - -�-- 1 .9iL FOR 2ND&3RDFis E -�-- U EX N D N has RR S AIR AIlt I 3 0l Am OfflCEOFFICE 1 2 OF 3RD FL I I l t.s1cTo3noFL zA ISM I j � 51. a s INFECTIOUS EX W 00 t S OFFICE s j s H P� RPs 1•nw• W�I M WASH ELEV LI• 1• RPS 1• ROOM j 13 EOL 4. 15 OBE o 15cd BACE j ® 15cd A BE KH ®1 SUTTE 201 H H H 17CAM SIN us 1•Ni-05 ,SUTIE 210 RPs 1•N4 15.d IP H SLflT 20 Ij OFFICE RPS 1•Ni-03 o I RPS•N4.O8 RPS 1• •10 A- -- c — H —OPEN EXAM 15cd S1 »U RR 75cd — BREAKRR RPS 1•N3-02 ROOM 1•N4-05 j B - i - - - - - - - -j - - - - - - - - - H- i - - - - - - - -j - - - - - - - - - - - � - - - - - - RI ttva•oa - -i-- 0 j - - - - - j j - - - - - -j — jj j - - - - - - O O DATE: 04.09.2025 2 � J J N m N LLIZrn _ — Q aWz Y O O N � Mz LEVEL 2 co SCALE:1/8"=1' U to Q City of Arlington Building Department APPROVED Kevin Olander-05/01/2025 SHEET TITLE No changes authorized unless approved by the Building Official FIRE ALARM LEVEL 2 FLOOR PLAN SHEET NUMBER FA 2.0 L7L'17 FIRE PROTECTION INC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 www.fpiseattle.com DEVICE IDENTIFICATION LEGEND INSTALLATIONKEY NOTIFICATION DEVICES (1) FIRE ALARM CONTROL PANEL.NEEDS DEDICATED 120VAC CIRCUIT. moo LINE TYPE LABEL CABLE TYPE AMU RESIST(UM) DESCRIPTION K-003 (2) REMOTE POWER SUPPLY.NEEDS DEDICATED 120VAG CIRCUIT,CAN SHARE WITH THE FACP.WIRE CIRCUIT NFPA (RPSI:NAC5)TO THE RPS's ONBOARD TROUBLE CONTACTS TO SUPERVISE FOR AC POWER/BATTERY FAULT A 142 FPLR 14 3.07 NAC:NODFICATIONAPPDANCECIRCUIr DEVICE NLA13EN R TROUBLE CONDITIONS.(SEE RPS INSTALLATION MANUAL) 000805173 NAC CIR=NLA43ER ® WIRELESS FIRE ALARM AES 2.0 COMMUNICATOR.NEEDS DEDICATED 120VAC OUTLET,CAN SHARE WITH THE FACP. • D 1614 FPIR 16 4.87 DATA:A1JfJ VCDJ0R CIRCUIl' LL NA(;Cj[ZC[)j'j' (4) REMOTE FIRE ALARM ANNUNCIATOR. ROY L CATS D 182FPIR 18 7.77 SIC:SIGNALINGLMCIRCUT ADDRESSABLE DEVICES ® TRIM RING FOR REMOTE FIRE ALARM ANNUNCIATOR TO ALLOW FOR WIREMOLD. QpOTECrj e� oy z 1s2 FPIR )s 777 I1c:ANAIDGINRIAIIIVGDEVICE CIaCGrr ®��mOt SURFACE MOUNT BACK BOX FOR MANUAL PULL STATION TO ALLOW FOR WIREMOLD. LET ADDRESSABLE RELAY FOR ELEVATOR RECALL.COORDINATE CONNECTIONSAll CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION CONDITIONS,PER THE REQUIREMENTS DEVFCENUM ER INSTALLATION OF WIREMOLD TO PROVIDE A CLEAN PATHWAY IN THE MAIN ENTRY ALCOVE FOR ANNUNCIATOR AND Y NFPA"OF IBC,IFC,NPFA-72&NFPA-70(NEC) MANUAL PULL STATION WIRING.DEMCE TYPE SLC =NU�� OMOUNT OUTDOOR BELL TO BE SEEN BY INCOMING EMERGENCY VEHICLES. CFPS SIB;ORCU1T• LO NEW DOCUMENT CABINET. #1473 u# _ W F O 2V� K Q N=m K W O F 6 F Z2UN I, QC J C7K UQpWHQ .Ulm YooW� 3 � o 3 W W y � pK KlWgJ6 O EXAM EXAM SSG. EXAM EXAM EXAM EXAM FANI REVISION RECORD �777 WAG RPSz•N1.03 DATE/DESCRIPTION A 15cd H H W G H RPs z•N1 RPs z•Nwta Res z i RPS2• 2•N4-04 UP 15cd I WAJT 1 •LP ❑ ROOM HIT ® z Naoa OFFICE AREA T S„G. RPS2•N1 11 92•N4-0 STAFF R 9 d O 15m Res 2•N1-09 RECEPI'fON � H Sfffl�3 5 Ism RPS 2•N4.13 EOL4.7k RPSz� SLIlTE305 .� GFFI H IS 12' RPS 2• `vl 15cd— INfHF PN IN ON 15cd $� $T OMSECOMIF[DOR FAIL 2 $2• •06 $ 2 RP52 •03 3NCFIRSFOR3RDFL 2 STG. M. 00 CAM txa STG. scFOR3aD SUIFE300 SUIIE306 H RP 30.1 EXAM EXAM ILL 15 A H S S10 ® WATT FI EV LI•D003 RPS 2•N-03 AREA RPS 2•Ni 8 RPS -05 RPS'• WORK 30m Ti ISm "�•y��p�/�,.' AREA H EXAM RPS 2•N2-04 30 SUITE 309 EXAM EXAM EXAM �.A S RPS IS H MULTIPLE REV O 15m BPS 2-M-11 OMCE OIFICE 3om - - - - - - - p - - - - -- -- RPS 2- s - -RPS 2- •a Res. - Res -0s OFFICE - -- O 7- 15m 15m Ism 1 OFFICE Resz• •1zEOLa.7k LEE 11 SUITE 3 7 15m C - - - -i - - - - - - - -- C 30m W OFHCE - - - - - - I - - - - - - - - - - - - - - - I DATE: 04.09.2025 2 � J J N m N L1JZrn _ — Q aW0 Y O O J M Z LEVEL 3 COZi MOW SCALE:118"=1' Q U cep City of Arlington Building Department APPROVED Kevin Olander-05/01/2025 SHEET TITLE No changes authorized unless approved by FIRE ALARM the Building Official LEVEL 3 FLOOR PLAN SHEET NUMBER FA 3.0 L7L'17 FIRE PROTECTION INC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 M DK-fpiseattle.com PANEL PANEL PANE, NEW-(GWF 7075)BATIERYCALLUIIATION (HPF24S6)BATTERYCALCTIIATION (SECONDARYPOWER SOURCE REQUIREMENTS) (SFC7NDARYPOVJER SOURCE REQUIREMENTS) (SECONDARYPOWER SOURCE REQUIREMENTS) STANDBYCURREM' SECONDARYAIARMCURREM' STANDBY CURRENT SECONDARYAIARMCURREM' STANDBYCURREM' SECONDARYAIARMCURRENT QTY PARTNB. DESCRIPTION CURREM'DRAW(A) TOTAL(A) CURREM'DRAW(A) TOTAL(A) QTY PARTNB. DESCRIPTION CUARENTDRAW(A) TOTAL(A) CURRENCDRAW(A) TOTAL(A) QTY PARTNO. DESCRIPTION CUARENTDRAW(A) TOTAL(A) CURRENTDRAW(A) TOTAL(A) NIELIGENTFIRE ALARM 1 IFF24S6 6-ANP,2-WLT POMER SUPPLY 0 0 0 0 1 HPF24S6 6-ATIP,24-WLTPOWER SUPPLY 0 0 0 0 PANEL COMPONEMS CONIROLPANEI.RID 1 GVVF-7075 0 0 0 0 PAN FIRE AIARMPOWER SUPPLYELCONPONENIS PANELCONPONENIS FIRE AIARMPOWER SUPPLY ABII LPAIS FIRE ALARM 1 HPFIAS6MAAIBOARD BOARD 0.091 0.091 0.145 0.145 1 HPF7AS6M1A,NL3OARD BOARD 0.091 0.091 0.145 0.145 171A 1 GWP-7075 MAINI30ARD COMROLPANE.MIAINI30ARD 0.165 0.165 0.31 0.31 CIRCUIT SYMBOL MY PARTNB DESCRIPTION CURREMTDRAW(A) TOTAL(A) CURREMTARAW(A) TOTAL(A) CIRCUIT SYMBOL QTY PARTNO DESCRIPTION CURRFNTDRAW(A) TOTAL(A) CURRENTDRAW(A) TOTAL(A) CIRCUIT SYMBOLL, QTY PARTM DESCRIPTION CDRRErrrERAW(A) TOTAL(A) CURRErrrERAW(A) TOTAL(A) z-wIRE TTDRN5TRD13E, y�y HORN STROBE CEJUNG.µFT E 000805173 EIOBNSTROBE,CERAG,WTIIIE 1 P. STANIDARD Cq REL}OlJ11X]OR 0 0 0.221 0.221 �'( 4 PCdWTPD 15CD 0 0 0.035 0.14 3 P(2W7ID 15CD 0 0 0.035 0.105 WP IIOCD � HORN STROBE,mtNa mn BPS 2-NI H I PC2WTED TORN STROBE'CEILDr,WULFF o 0 o.o3s 0.038 ROY L CATS 1✓^( t P(2W7ID �RNS'IROBE'CEQ-INC'WHI7E 0 0 0.087 0.087 5 PC2WIID 15CD 30CD 0 0.035 0.175 30CD ({OTECl FPCP•NI W RPS 1•Nl M 9 SCWIID STRO13F,CEILING,WHITE 15CD 0 0 0.018 0.162 7 SCWTED STRODE,CEOPJG,WHITE 15CD 0 0 0.018 0.126 5 SCWTED STROBE,CEILING,WHITE ISCD 0 0 0.018 0.09 -\ w 5 PCZWTED HORN STROBE,CEILING,,VVFTE o 0 0.035 0.175 Yy NF•WPPA" WTE I SCD STROBE,CmnvG,WHITE 30CD 0 0 0.022 0.022 1 scWTED STROBE cmPac,WHITE 30CD o 0 o.ozz o.ozz 15CD �� y5 RPS 2•N2 CEPS H 6 P(2. HORN STROBE,CEILING'WITTIE 0 0 0.035 0.21 /-1 5 SCW41D STRO13F,CEILING,WHITE 15CD 0 0 0.018 0.09 #1473 FPCP•NL 7-7 2 HPF2456 6-AMP,24WLTPOWERSUPPLY 0 0 0.069 0.138 15CD RPS 1•NL � HORN STROBE,CEJUNG.VVHTDE ADDRESSABLE 2FORMJIFIIEM 1✓^( 1 P(2WIID 15CD 0 0 0.035 0.035 3 PDM2RF FIASI-SCA>\j 2 FORMC DRY 0.0003 0.0009 0.0003 0.0009 � 7 SCW'IID STROBE,CERINC,WHITE ISCA 0 0 0.018 0.126 CONFAM yy,;;;CC HORN STROBE,CEILING,WHITE #ry PI-IONEP.CIRIC SMDEE y,� HORN STROBE,CCERING,WHITE BPS 2•N3 �'( 4 PC2WTID 30CD 0 0 0.038 0.152 # DETECTOR.BRIGHT WHUF, u 5 PC2WIID 0 0 0.035 0.175 lI O 5 ASDPL3 W63gW VIIIXTD W 6,FLANGED 0.0002 0.001 0.0045 0.0225 15CD =j a r- VELOCRIABASE,BRIGHSABLE WHTE 9y,� HORN STROBE,CEILING,WHITE � 7 SCW4ID STRO13F,CEILM,,WHITE 15CD 0 0 0.018 0.126 w� ❑ RPS l•M � 1 P(2WIED 0 0 0.087 0.087 2.> > VIIDCPIIAIA%2FSSAB[E SINGE 75CD Z-- 19 ❑F 7 MS-7ASF 0.0003 0.0021 0.007 0.049 r Z ., W ACTION STATION � HORN STROBE,CEILING,,VVFTE QWUm W 1✓^( 5 P(2WTID 0 0 0.035 0.175 y= y 1T7G1LSTANIDBY(A) 0.169 TOTALALARM(A) 0.86040 � 6 SCWTID STROBE,CEILING,WHITE ISCT3 0 0 0.018 0.108 ISCD rc U REQUIRES STAWBYTIMB(FIDURS) 24 BPS 2•NO w if'.d. F AIARMTI E y�y �/ ❑O 6 U = SECOISDARYSTANDBYLOAD(A) 0.169 REQUBID 7A (h/N[71E5) 4.06 H 4 PC2VA® ITORNSTROHE,CEILINCI,WI-IIlE 0 0 0.035 0.14 �"� 5 SC NLED STROBE,CERINC,WHITE 15CD 0 0 0.018 0.09 4❑ a O SECON)ARYALAIUAMAD(A) 0.86040 0.083 0.0717 15CD U Q Y p H J STANDBYAND ALARMSUBIOTAL(AMP DOM) 4.13 RPS 1•M TOTALSTANIBY(A) 0.091 TOTALAUIRM(A) 1.33 1BRATATO FACTOR 1.25 9 SCWTED STROBE,CEILING,WHITE I5M 0 0 0.018 0.162 Z REQUIRED STAN�YWYE(HOURS) 24 >>W LL SEcoF%ARYuOADxPQUIREKINTS(AMPFIDURS) 5.16 REQrn EDALARMTNE61FA ES) 5 a o o LL in 3 TOTALSTMIMY(A) 0.091 TOTALALABM(A) 1.66 SECONDARYST,1NEBYLOAD 0.091 as 1 2.19 z w w a REQ[IILtEDSTANDBYTME(I-LOURS) 24 SECONDARYALARMIFAD(A>) 1.33 0.083 1 0.111 QQ 3 3 V W IBATIERYBDXSIZECAPPCLIYNY7r SPECIFIED.REFER TO MANLLFACTURERDOCUMENFATION REQUIRED AIARMTME(MNlJ1E5) 5 K W W ^8 K Q STACHYANDALARMSUffrOTAL(AMPHOURS) 2.29 >>Q O > DERATFVG FPLTOR 1.25 G rc rc M a ❑ SECON 3ARYSTANIBYLOAD(A) 0.091 24 2.18 SECONDARYLOADREQUIREMEMS(AMP HOURS) 2.87 SECDN�RYALARM10AD(A) 1.66 0.083 0.138 REVISION RECORD STAMMYAT-DALARMSUBTUTAL(AMP HOURS) 2.32 DERATING FAOIOR 1.25 DATE DESCRIPTION 13ATIERYI3DXSLZE CAPPCLIYNOI'SPE(7FFIED.RIPERTO MFINUFAd'IURII2I]OLTJMENCATION SEC'ONDARYLOAD REQl11RENENIS(AAP[OURS) 2.90 (2)V1 INNER Y3ATTERYBOXSIZE CAPA=,DT SPEC6TED.REFER TO MWNUFACTURER IX)CITPNrAT10N. BATTERY CALCULATIONS A BPS 2•N4.10 EOL4.7k BPS 2•N-09 BPS 2•N4-08 BPS 2-M-07 BPS 2•NO.06 BPS 2•1-MO5 BPS 2•N1.04 BPS 2•NO-03 BPS 2-M-02 BPS 2•N4-01 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd H H H H H RPS 2•M•12 EOL4.7k BPS 2•M•11 BPS 2•M•10 BPS 2•M•09 BPS 2•M-08 RpS 2•M•07 BPS 2•M•116 BPS 2•M-05 BPS 2•M•04 BPS 2•M-03 BPS 2•13-02 BPS 2•M-01 15cd 30W 30cd 15cd 15cd TOW 15cd 15cd 15cd 30cd 15cd 15cd A H H H H H S F F BPS 2-M-10 EOL4.7k BPS 2-M-09 BPS 2-M-08 BPS 2•M-07 RPS 2•M-06 BPS 2-M-05 BPS 2-M-04 BPS 2•M-03 BPS 2•M-02 BPS 2-M-01 U-DO03 LI•MB06 Lt•MD07 15cd 15cd 15cd I5cd 15cd I5cd 15cd 15cd 15cd 15cd ___________________________________________________________________________ A H H H H H RPS2•M•14BOL4.7k BPS 2•M•13 BPS 2•M•12 RPS2•M•11 BPS 2•NI.10 BPS 2•NI.09 BPS 2•NI-08 RpS 2•M•0'7 BPS 2•NI-06 BPS 2•NI-05 BPS 2•NIdW BPS 2•M-03 BPS 2•M-02 BPS 2•NI-01 15cd 15cd 15cd 15cd 30cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd A H H H H BPS 1•NO.13 EOL4.7k BPS 1•NO.12 BPS 1•NO.11 BPS 1•N4.10 BPS 1•N4.09 BPS 1•N4-08 BPS 1•NO-07 BPS 1•NO.06 BPS 1•N4-05 BPS I-M-04 BPS 1•NO-03 BPS 1•NO-02 BPS 1•N4-01 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd A H H H H H H S F F BPS I•M•12FOL4.7k BPS I•M•D BPS 1•1,3U0 BPS 1•1,3•09 BPS 1•1,3-09 BPS I•M•07 BPS I•M•06 BPS I•M-05 BPS 1•1,3•04 BPS I•M•03 BPS I•M•02 BPS I•M-01 U-DO02 Ll•MD04 LI•M)05 DATE: 04.09.2025 15cd 15cd 15cd 15cd Iscd 15cd 15cd 15�d 15cd 75cd 15cd 15cd OR ---------------------------------------------------------------------- ----- - -- --------------------- ----------------------------------- - - A A WEXPAMER AES PDWIBSUPPLY 4Z Q H J N J m N A �)mowmsUPPLY Ra ens Q00 A LLI Z H H H H H H S S S F F F O Q BPS I-M-13 FOL4.7k BPS I-M-12 RPS I-M-11 BPS I-M-10 BPS I-M-09 BPS I-M-08 BPS I-M-07 BPS I-M-06 BPS I-M-05 BPS I-M-04 BPS I-M-03 RPS I-M-02 BPS I-M-01 A D L1•L3001 Id•DO04 LI•DO05 LI•MI01 L1•M302 LI•M1303 LI-ND08 U-Nm LI•MIIO Y d 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd I5cd aLU0 � 0 (9 A AM J Z H COH H H J BPS 1•M•12BOL4.7k BPS 1•M•11 BPS 1•NI.10 BPS 1•N1-09 BPS 1•NI-08 BPS 1•M-07 BPS 1•M•116 BPS 1•NI-05 BPS 1•NI-04 RPS 1•NI.03 BPS 1•M-02 BPS 1•NI-01 G 110.d 15cd 30cd ISM 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd Q WP U to A A FACP•Nl•12EOL FACP•NI.11 FACP-M-10 FACP•Nl•09 FACP-M-08 FACP•NI-07 FACP-M-06 FACP-M-05 FACP•NI-04 FACP•NI-03 FACP-M-02 FACP-M-01 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 30cd 15cd 75cd SHEET TITLE --------------------------------------------------------------------------------------------------------------------------------------- 1STFLOOR FIRE ALARM BATTERY CALCULATIONS City of Arlington s SINGLE LINE RISER DIAGRAM SINGLE LINE RISER Building Department DIAGRAM APPROVED Kevin Olander-05/01/2025 SHEET NUMBER No changes authorized unless approved by the Building Official FA 4.0 L7L'17 FIRE PROTECTION INC. 17410 Ash Way,Ste 8 Lynnwood,WA 98037 (425)290-9600 CURRENr SLTJAARY POWER SunMIARY CURRENT SUbMNRY POWER SVM,MRY www.fpI eattle.com TUEALCIRCUB'CURRENT 0.34 MAX VOLTAGE DROP 0.23 1OTALCRCUT 0.302 MAX VOLTMEIROP: 0.47 (A): STARTIMUCAIC. (A): STARTIIUCAIC. MAX CRCUfl'C[RRENT SPARE CIRCUIT VOCIAGE: 20.40 MAX C2QATCURRENT SPARE CIRCUIT' VOLTAGE: 20.40 1 0.660 VOLTAGE DROP% 1.14% 3 2.70 VOLTAGE DROP 2.29% FACP•M POIM"TCYPOINI'REPORT (.°�: PARE CIRCUIT RPS 1 N4 POIM'TO-POINI'REPORT (.°�: PARE CIRCUIT SPARE CTRCLIII' MN OPERATIONAL SPARE CIRCUIT MN OPERATIONAL 66.00% 16 VOLTAC;E: 20.17 89.93% 16 ENDOFI]NE VOLT C[RRENIE%' VOLTAGE: CURRENT%' VOLTAGE 1OI'ALCARDCURRENT TGEALCRCUITLENCiTII 1OI'ALCARDCURRENT TOTALCIRCUTTTENGTI I 0.55040 201 1.52 365 (!�: WIRE RESISTANCE (FT). (A); 1.52 RESISTANCE (FL): SPARE CARDCURRENT (�); 3.07 TOTALCIRCUIT SPARE CARDCIIRRENT (SYKFI): 3.07 TOTALCIRCUIT NFPA CRCURWIRINC PROPERTES:'A 14/2}PIP/R(NM)14 A6VG,2COND.SOLID COPPER PPIP/RANAUX'i UNSIOEIDED MIX CARDC[Il2RENT(e>): Na (A). �ST��(� 1.23 CIRCURWIRWG PROPERTIES:'A 142 FPIP/R(NAL)14RAU,2COND SOLID COPPER FPIP/RANALOG 12-81HEEDED MIX CARDCURRENT(A): a/a (A), RESISTANCE 2.24 DLSTANTNEASURPDLSMDRAWNSE(!K TM4 IFS WITH 10.00%AIXXTIONALIENUINC4InrtnTFfl SPARE CARDCURRENT DISTANCE hEASUREDUSINGDRAWNSEGIVEFIETENCIES WEIN 10.00%ADEnIoNALTENCIIII r.a SPARE CARDCURRENT 000805173 REMAINNO ALARM DISTANCE FROM RESISTANCEFROM VOLTAGE DROP FROM V)LTAGEDROP REMAR UALARM DISTANCEFROM RESIST94MFROM VOLTAGE DROP FROM VOLTAGEDROP DEVICE LABEL PARTNJ DESCRIPTION CANUQAS AIARMC[RREM'(A� VOLTAGE ATIR4ICE TOTALVOLTAGEIROP DEVICE LABEL PARTNO DESCRIPTION CANDELAS ALARMCURREN(A) VOLTAGE ATIEVICE 1DTALVIXTAGE RROP CURREN'(A) PREVIOUS PREVIOUS(n) PREVIOUS PERCENT' CURRENT(A) PREVIOUS PREMIX,6(S2) PREVIOUS PERCENT' ROY L CATS FACP•NI-01 PC2VV ED HORNSTROEE,CERM,WMIE 75CD 0.087 0.34 34 0.208537 0.07 20.33 0.07 0.35% BPS l•N4-01 SCWIED STROBE,CEEM,,WHITE 15CD 0.018 0.302 150 0.9210 0.28 20.12 0.28 1.36 FACNNI-02 SCVVUED STROBE,CURING,WMIE 15M 0.018 0.253 24 0.145876 0.04 20.29 0.11 0.53% BPS I•N4-02 PCWIED BORN STROBE,CLING,WHITE 15CD 0.035 0.284 16 0.097596 0.03 20.09 0.31 1.50% ?IkOTECl7 FAGP•M-03 SCWIID STROBE,CURING,WNIIE 30CD 0.022 0.235 20 0.122696 0.03 20.26 0.14 0.67% RPS 1•N4-03 SOWED STROBE,CERM,,WHITE 15CD 0.018 0249 17 0.103346 0.03 20.07 0.33 1.63% Q�4 Oy FAGP•M•04 PC2WIED HORN STROBE,CERM,WMIE 15CD 0.035 0.213 23 0.141398 0.03 20.23 0.17 0.82% RPS 1•N4.04 PC2WTID HORN STROBE,CEILDr,WHITE 15CD 0.035 0.231 31 0.189806 0.04 20.02 0.38 1.84% 4 •1 Na FACP•M-05 PC2WED HDRNSTROBE,CERM,,WHIIE 15CD 0.035 0.178 21 0.127462 0.02 20.21 0.19 0.93% BPS 1•N4-05 SCWLED STROBE,CEIIRIQ,WMIE 15CD 0.018 0.196 15 0.089795 0.02 20.01 0.39 1.93% w M n FACP•M416 SCVVUED STROBE,CEEM,,WMIE 15CD 0.018 0.143 17 0.103958 0.01 20.20 0.2 1.00% BPS I•N4-06 SCWLED STROBE,CURING,WHITE 15CD 0.018 0.178 11 0.065027 0.01 20 0.4 1.98% 1 '•, FACP•M-07 SCVVUED STROBE,CEHM,,WHITE 15CD 0.018 0.125 12 0.070611 0.01 20.19 0.21 1.04% RPS 1•NM07 PC2VJM FORN STROBE,CEU\-,WHITE 15CD 0.035 0.16 14 0.osaa 0.01 19.99 0.42 2.05% Yy NFPA" FPCP•M-08 SCWLID STROBE,CEILING,WHIIE 15M 0.018 0.107 10 0.060847 0.01 20.18 0.22 1.08% RPS 1•1,4-08 SOWED STROBE,CEEM,,WMIE 15CD 0.018 0.125 24 0.144634 0.02 19.96 0.44 2.14% FAGP•M•09 SCWIID STROBE,CEBIIY',WMIE 15CD 0.018 0.089 11 0.06792 0.01 20.17 0.23 1.11% RPS 1•N4.09 PC2WTID HORN STROBE,CEtURK1,WHITE 15CD 0.035 0.107 15 0.09409 0.01 19.95 0.45 2.19% CFPS FAGP•M•10 P(2WIPD HORNSTROBE,CEIL]NY',WI-IIIE 15CD 0.035 0.071 9 0.052465 0 20.17 0.23 1.12% BPSI•N4.10 SCWLED STROBE,CEBINC,WMIE 15CD 0.018 0.072 25 0.153W 0.01 19.94 0.46 2.24% #1473 FACP•NI.11 SCVVUED STROBE,CEILING,WHITE 15CD 0.018 0.036 8 0.0472% 0 20.17 0.23 1.13% BPS l•N4.11 SCWLED STROBE,CERM,,WHITE 15CD 0.018 0.054 17 0.102609 0.01 19.94 0.46 2.27 FACP•M•12 EOL SCVVUED STROBE,CEILING,WHITE 15CD 0.018 0.018 14 0.083992 0 20.17 0.23 1.14% RPS 1•1,4.12 SOWED STROBE,CERM,,WHITE 15CD 0.018 0.036 12 0.076597 0 19.93 0.47 2.28% CALCULAIIONioETTIODS: BPS I-M-13 EOL4.7K SOWED STROBE,CEILING,WMIE 15CD 0.018 0.018 19 0.119185 0 19.93 0.47 2.29% RESISTANCE FROMPREVIOUS(Q)=WIRE RESISTANCE(QFT)X2 XDIST.FROMPREVIOUS(FT) CALCU ATIONNETHODS: VOLTAGE DROP FROMPREVIOUS-RESISTANCE FROMPREVIOUS(P XREM4IlVRvY'CU MENT(AA) RESISTANCE FROMPREIAOLIS(Q-WIRE RESISTANCE(f(I)X2 XDST FROMPREVIOUS(FT) VOLTAGE DROP FROMPREMOUS-RESISTA UE FROMPREVLOUS(r))XREMAINR 'CURRENT(AA) ## CURREM'SUMv14RY POWER SUMvIARY CURRENTSLMvNRY POWER SUMvL1RY = a TOTALCIRCUD'CURRINT w 0.138 MAX VOLTAGE DROP: 0 TOTALCIRCUIT - (A): STARTING CALL. 0.34 MIX NOLTALE DROP: 0.570 20.40 (A): STARTINGCALC. w� ❑ MAX CRCUI'CURRENC SPARE NF(_10C VOLTAGE: 20.40 =V 1 0.8620 VOLTAGE DROP%' 0.02% MAX CRC(A): RENC SPARE CURRENT(A): VOLTAGE: =H y FACP•M POIM-IO-POR4TREPORT (�: CURRENT(ey: RP52M POINT-7T}PO1M'REPORT (�: 3 CURRINI'(e>): 2.66 VOLTAGE DROP 2.77% SPARE CRC[IIC MN.OPERATIONAL Q w V 0• W CURRENT% 86.20% VOLTAGE: 16 LIRE VOLT SPARE CIRCUIT 88.67% MN.OPERATIONAL 16 VOLT rc rn=u IY TOTALCARDCURRENF TOTALCIRCUITIENG7H CURRENT%' VOLTAGE: w 3 a F 0.55M s 1DTALCARDC[RREN TOTALCRCUITII]4GIH p O 4,U x (A): VARE RESISTANCE (FI): 1.18 390 z M SPARE CARDCURRENT (O ; 3.07 TOTALCRCUIT RD WARERESISTANOB 3.07 a❑ j# K CIRCUIT WIRING PROPERTIFS:'A 142 FPIP/R(NAC)14 AWG,2 CONE,SOLO)COPPER FPLP/R ANALOG UNSHIELDED M4X CARDCURRENT(A7): da 0.032139 SPARE CARDCURRENI' (SNUG�11): TOTALCIl2CUIT (A): RESISTNJCE(Q. CIRCUIT WRING PROPERTIFS:'A 142 FPIP/R(NAC)14 AMD,2COFm.SOLID COPPER FPIP/R ANALOG UNSTILEDDED M4XCARDCURRENT(A>): ¢/a (�: RUTALCIR UIT 2.40 U Q IO W H J Y O Q INSTANT bEAS[RID[xS1NY3IRAWNSEQvENI'IITRiIf$WITH 10.00%AIHIIIONALIINCi1T7CACULATID SPARE CARDCURRENT SPARE CARDCURRENF U..�•. e DISTANCE bEASUREDUSM ERAWN SECIVENT DENOTES WTTH 10.00%ADCITTONALIENCinl CALCULATED Z!!w w REMAINING ALARM DISTANCE FROM RESISTANCE FROM VOLTAGE DROP FROM VOLTAGE IROP % m M N O DEVICE LABEL PARTNO DESCRIPTION CANDELAS AIARMCURRENF(A) VOLTAGE AT DEVICE TOTAL VOLTAGE DROP ItEMAII4R•AIALARM DISTANCE FROM RESISTANCE FROM VOLTAGE DROP FROM VOLTAGE DROP !O O LL CURREM'(A) PREVIOUS PREVIOUS PREVIOUS PERCENT DEVICE LABEL PARTND DESCRIPTION CANDELAS ALARMCURRENr(A) NINRUAL� PREMOLR PREMOCE FR PREVIOUS VOLTAGEATDEVTCE TUEALVOLTAGEIROP PERCENT i w w W Q f HPF24S6 6-AW 24VULTPOWERSUPPLY O.1169 0.138 3 0.016988 0 20.40 0 0.01% 3 3 U w RPS 2•M-01 SCWIID STROBE,CEB]No WMIE 15CD 0.018 0.34 150 0.9210 0.31 20.09 0.31 1.54% G?i W W u y ❑ HPF24S6 6-ANP,74-VOLTP0WERSUPPLY O.W9 O.W9 2 0.015151 0 20.40 0 0.02% RPS 2•M-02 SCVVUED STROBE,CEILING;WMIE 15CD 0.018 0.322 10 0.059618 0.02 20.07 0.33 1.63% K w w w^b Wo CALCULATAN4DvE1TADS: G rc 19 W J a ❑ RESETANOB FROMPRElI011I(0)=WIRERESISTANT(aFT)X2 XDIST FROMPREVIOUS(FT) RPS2•M•03 SCVVUED STROBE,CEILING,WIDE 15CD 0.018 0.286 13 0.059362 0.02 20.03 0.37 1.75 83% VOLTAGE DROP FROMPREVTOUS=RESSTA]UE FROMPREVTOUS(G)XREMANM CIRRENT(A) RPS2•M-04 CWIPD STROBE OBE,C L WHITE 15CD 0.035 0.268 16 0.059362 0.03 20.03 0.4 1.83% REVISION RECORD RPS 2•M-05 PC2WIID FpRNS1ROBE,CERAG,WHITE 15CD 0.035 0.268 16 0.100605 0.03 20 0.4 1.97 RPS2•M-06 SCWLID STROBE,CEIIRIQ WMIE 15CD 0.018 0.233 17 0.102335 0.02 19.98 0.42 2.08% DATE DESCRIPTION PPS 2•M•0'7 PC2VAM HORN STROBE,CUM,WMIE 15CD 0.035 0.215 28 0.170342 0.04 19.94 0.46 2.26% PPS 2•M418 SCVVUED STROBE,CURING,WHIIE 15CD 0.018 0.18 19 0.114165 0.02 19.92 0.48 2.36% BPS 2•M•09 SCWIID STROBE,CERM,,WHIIE 15CD 0.018 0.162 31 0.188638 0.03 19.89 0.510 2.51% RPS2•M•10 PC2WIED HORNSTROEE,CERMVVH1IE 30CD 0.038 0.144 21 0.130069 0.02 19.87 0.530 2.60% RPS2•M•11 SCWIED STROB$CEILINC,WMIE 15CD 0.018 0.106 19 0.117857 0.01 19.86 0.540 2.67% RPS 2•M•12 SCWIED STROBE,CEILING,WHITE ISCD 0.018 0..II 23 0.140462 0.01 19.84 0.560 2.73% CURRENT STJNMNRY POWERSUMMARY RPS 2•M•13 PC2WLFD BORN STROBE,CELM,,WHITE 15CD 0.035 0.07 10 0.064012 0 19.94 0.560 2.75% TOTALCIRCUITCURRENT RPS 2•M•14 EOL4.7K PC2WIED BORN STROBE,CELM,,WHITE 15CD 0.035 0.035 74 0.146375 0.01 19.83 0.570 2.77% (A), 0.5080 STARTMCALC. MIX VOLTAGE DROP: 0.720 CALCULATIONhETTIODS: MIX CRRLVITCURREM' SPARE CIRCUIT VOLTAGE: 20.40 RESISTANCE FROMPREVIOUS(f2)=WIRE RESISTANCE(EYF'T)X2 XIIST.FROMPREVIOUS(FT) RPSIMPOINI'-74PO1M'REPORT (A): 3 CURRENT(A): 2.49 VOLTAC:E DROP%: 3.51% VOLTAGE DROP FROMPREVLOUS-RESISTANCE FROMPREVLOUS(S�XREM4IlVRvY'CURRENT(A) SPARE CIRCUIT 83.07% MN'OPERATIONAL 16 END TKE: 19.68 C[RRENE%' VOLTAGE: C[RRENESUTvMARY POWER SUMvWRY TOTALCARDCURRENT TOTALCIRCUITIENGTH 7OTALCRCUIT (A): 1.52 WIRE RESISTANCE 3.07 WE. 323 (A), 0.265 STARTINGCALC. MAX NOULACE DROP: 0.46 SPARE CARDCURRENT (ENTI): TOTALCIRCUIT MAX CIRCUH'CURRENE SPARE CIRCUIT VOLTAGE: 20.40 CRCURWIRI4G PROPERTIFS:'A 142}PIP/R(RNG)14 AWG,2COND.SOIIDCOPPER FPIP/RANAIOC UNSIREIDED MAX C4RDC[IlRRENT(A>): Na (A), RESISTANCE(12): 1.98 7WBPS 2 N2 POINT-TO-POINT REPORT (A); 3 ��.(A): 2.74 VOLTAGE DROP% 2.25% SPARE CARDCURRENT]ISTAJCEbPAS[RID[S1RN;DILAWNSEG[vENELERK:HS WI1H10.00%ADIIlIONALLERKiIHCATrIrtnTFT Y SPARE CRC[III' MN.OPERATIONAL CURRENT,% 91.17% VOLTAGE: 16 OF LIRE VOLT REMAVID4C'AIARM D7ISTANCE FROM RESISTANCEFROM VOLTAGE DROP FROM VOLTAGE DROP DEVICE LABEL PARTNJ DESCRIPTION CANDELAS ALARMCURREN(A) VOLTAGE AT DEVICE TOTALVOLTAGEIROP CURREM'(A) PREVIOUS PREVIOUS(fI) PREVIOUS PERCENT' 1.18 WARERESLSTANOB (�; 363 BPS 1•M-01 SCWLED STROBE,CEILING,WIDE 15CD 0.018 0.5080 7 0.043464 0.02 20.38 0.02 0.11% SPARE CARDCURRINT (S4RYl): 3'07 TOTALCRCUIT BPS 1•M•02 SOWED STROBE,CEILING,WIDE 15CD 0.018 0.49 16 0.099402 0.05 20.33 0.07 0.35% CRCUIT WIRINGPROPERTIFS:'A 142 FPIP/R(NN,)14 AWL,2 COND.SOLD)COPPER FI'IP/R ANALOG UNSFIF.IDED MAX CARD C[RREN(A>): n/a (A), RESSTANCE(Q. 2.23 RPS 1•M•03 PC2WIED HORNSTROBE,CERM,WMIE 15CD 0.035 0.472 39 0241592 0.11 20.22 0.18 0.91% SPARE CARDCURRENT BPS I•M-04 PC2WIED HORNSTROBE,CERM,WMIE 15CD 0.035 0.437 39 0.239231 0.1 20.11 0.29 1.42% LISTAFR:EbEAS[RID[xS1NY31RAWNSEQvENTIITRiIf$WHH 70.00%AIHIIIONALII74GIHCAILTIAIID RPS I•M-05 PC2VVED HORNSTROBE,CEQIN(',WMIE 15CD 0.035 0.402 39 0.238251 0.1 20.01 0.39 1.89% RESIAINNO ALARM DISTANCE FROM RESISTANCE FROM VOLTAGE DROP FROM VOLTAGE DROP BPS I•M-06 PC2VVED HORNSTROBE,CELM,,WHITE 15CD 0.035 0.367 26 0.159049 0.06 19.96 0.44 2.17% DEVICE LABEL PARTNJ ]I'SCR@T10N CANDELAS ALARMC[RRENE(A) (TRR�.(A) PREVIOUS PREVIDLB(f2) PREVIOUS VOLTAGE AT DEVICE TOTALVOLTACEIROP PERCENT BPS 1•M•07 SCWDID STROBE,CEHM,,WHIIE 15CD 0.018 0.332 15 0.094489 0.03 19.93 0.47 2.33% BPS 2-M-01 PC2WIED HDRNSTROBE,CELM,,WHITE 15CD 0.035 0.265 200 1.23 0.33 20.07 0.33 1.60 BPS I•M-08 SOWED STROBE,CEEM,WMIE 15CD 0.018 0.314 44 0.271294 0.09 19.84 0.560 2.75% BPS 2-M-02 PC2WIED HORN STROBE,CERM,WMIE 15CD 0.035 0.23 15 0.089525 0.02 20.05 0.35 1.70% BPS 1•M-09 SCWLED STROBE,CEILING,WMIE 15CD 0.018 0.296 24 0.14595 0.04 19.80 0.60 2.96% BPS 2•M-03 SCVVUED STROBE,CERII Y',WMIE 15CD 0.018 0.195 23 0.139602 0.03 20.03 0.37 1.83% BPS 1•M•10 SCWLED SIRCEE,CURING,WHIIE 30M 0.022 0.278 26 0.159929 0.04 19.75 0.650 3.18% BPS 2•N•04 PC2VV ED HDRNSTROBE,CELM,,WHITE 15CD 0.035 0.177 22 0.137294 0.02 20 0.4 1.95% BPS 1•M•11 PC2WIED HORNSTROBE,CURING,WHITE LICE) 0.035 0.256 22 0.132671 0.03 19.72 0.680 3.34% BPS 2-M-05 SCWIID STROBE,CEUNC,,WIDE 15CD 0.018 0.142 28 0.17456 0.02 19.98 0.42 2.07 2-V7M HORN STROBE, RPS 2-M-06 SCWIID STROBE,CERIIY',WMIE 15CD 0.018 0.17A 12 0.074578 0.01 19.97 0.43 2.12 RPS 1•M•12 EOL47K P2RK STANDARDCD RED O[ETX1O R HOOD 0.221 0.221 25 0.155815 0.03 19.68 0.720 3.51% RPS 2-M-07 SCWIID STROBE,CERII Y',WHITE 15CD 0.018 0.106 11 0.068044 0.01 19.96 0.44 2.15 CALCULATIONhETUDDS: RPS 2•M-08 SCWIPD STROBE,CERII Y',WHITE 15CD 0.018 0.088 14 0.084267 0.01 1995. 0.45 2.19% RESISTANCE FROMPREVIOUS(0)=WRE RESISTANCE(EYF'T)X2 XIIST.FROMPREVIOUS(FT) RPS 2•N•09 PC2VVED HDRNSTROBE,CELINQWHDE 15CD 0.035 0.07 20 0.121953 0.01 19.95 0.45 2.23% VOLTAGE DROP FROMPREMOUS=RESISTANCE FROMPREVIOES(SI)XREM4M,-,CURRENT(A) RPS 2•N2•l0EOL4.7K PC2WIID HDRNSTROBE,CERAG,WHTIE 15M 0.035 0.035 I8 0.110168 0 19.94 0.46 2.25% CALCUIIATIONNETTADS: CURRENT SL&MARY POWERSU MARY RESISTANCE FROMPREMOUS(f1)-WRE RESISTANCE(SEF'T)X2 XIIST.FROMPREMOUS(FT) TOTALCRCWTCURRINI' VOLTAGE DROP FROMPREVIOUS=RESISTANCE FROMPREVIOES(f2)XREMAIN➢ND CURRENT(A) A* 0.336 STARTINGCALC. MAX VUITAE DROP: 0.31 MAX CIRCUH'CURREN' SPARE CIRCUIT VOLTAGE: 20'� C[RRENESUATIARY POWER SUMvWRY 7 RPS IN2 POINT-74PO1NTRFPORT (A): 3 CURRENT(A): 2.66 VOLTAGE DROP% 1.50% SPARE CIRCUIT 88.80% MN.OPERATIONAL 16 TOTALCRCUITCURRINT (�_ 0.313 STARTINGCALC MAX VOLTAGE DROP: 7.47 CURREN'% VOLTAGE: MAX CIRCUTI'C[RRENE SPARE CIRCUIT VOLTAGE: 20.40 3 2.69 VOLTAGE DROP%: 7.20% 1DEILCA(A): EN 1.52 WIRE RESISTANCE TOh1LC(FEr IIJCi1TI 251 BPS 2N POINT-TO-POINTRFPORT (A): QRRENT(A): SPARE CIRCUIT MN.OPERATIONAL SPARE CARDCURREN (fDltf'I): 3'� TOTALCRCUIT CURREM'�, 89.57% VOLTAGE: 16 ENDOF LINEVOLTKE: 18.93 CRCUfTWI2AIGPROPER71E5:'A 142 FPIP/R(NrG)14 AWG,2COND.SOIIDCOP PERFPIP/R ANAIfIGUNSHQ:OI•.D MAX CARDC[RREN(A>): n/a 1.54 (A): RESISTANCE(S>): 1DEV.CARDC[RREN TOTALCRCUfTLENGTH SPARE CARDCURRINT11'IISTAFR:E bEASURID[TAGIRAWNSEC2vENTIEhRi1T6 WRD310.00%AffiIIl)NALIENCi1T7CACU[A1ID (.�: WIRE RESISTANCE (FIT 869 LC SPARE CARDCURREN ( ): 3.07 TOTALCRCUIT REMAINING ALARMDISTANCE FROM RESISTANCE VOLTAGE DROP FROM VOLTAGE DROP CIRCUIT W'IRAIGPROPER71E5:'A 142 FPIP/R(NPC)14 AWG,2COND SOIIDCOPPERFPIP/RANAIDGUNSHQ:0IJD MAX CARDC[RREN(A>): n/a 5.34 DUNCE LABEL PARTNJ II:SCR@T10N CANDELAS ALARMCIIRRII4T(A>) VOLTAGE AT DEVICE TOTALVOLTACEIROP (M: RESISTAFR:E(S7): C[R0.336 ) PREVIOUS PREVIOLS(f2) PREVIOUS PERCENT SPARE CARDCIIRRENT RPS 1•N2-01 PC2WIID HORNSTROBE,CEQINC,WMIE 15CD 0.035 0.336 28 0.172695 O.11b 20.34 O.W 0.28% IISTAFR:E bEASIRID[xS1NGIRAWNSEQvENTIITRiIf$WHH 70.00%AIHIIIONALIIPRi1TTCAILTJLAIID BPS I-M-02 SOWED STROBE,CEILING,WMIE 15CD 0.018 0.301 19 0.119068 0.04 20.31 0.09 0.46% REMAINING ALARM DISTANCE FROM RESISTANCE FROM VOLTAGE DROP FROM VOLTAGE DROP BPS 1•N2-03 PC2VVED HORN STROBE,CERM,WMIE 15CD 0.035 0.283 29 0.176574 0.05 20.26 0.14 0.71% DEVICE LABEL PARTNO, DESCRIPTION CANDELAS ALARMC[RRENE(A) CURR�.(A) PREVIOUS PREVIDLB(f2) PREVIOUS, VOLTAGE AT DEVICE 7C7EALVOLTACEIROP PERCENT RPS 1•N•04 SCWLED STROBE,CERM,,WIDE 15CD 0.018 0.248 17 0.102733 0.03 20.23 0.17 0.83% BPS 2•M-01 PC2WIED BORN STROBE,CELM,,WHITE 15CD 0.035 0.313 456 2.80 0.880 19.12 1.28 6.27 BPS I-M-05 SOWED STROBE,CERM,,WIDE 15CD 0.018 0.23 16 0.099064 0.02 20.21 0.19 0.94% BPS 2•M•02 SCW'LID STROBE,CEILING,WMIE 15CD 0.018 0.278 16 0.098643 0.03 19.09 1.31 6.41 BPS I-M-06 PC2WIED HORN STROBE,CERM,WMIE 15CD 0.035 0.212 21 0.129215 0.03 20.18 0.22 1.08% BPS 2•N-03 PC2WIID HORN STROBE,CERM,WMIE 30CD 0.038 0.26 16 0.100958 0.03 19.07 1.33 6.54% BPS 1•N•07 SCWLED STROBE,CEILING,WMIE 15CD 0.018 0.177 18 0.109797 0.02 20.16 0.24 1.17% BPS 2•N-04 SCVVUED STROBE,CERM,,WIDE 15CD 0.018 0.222 27 0.166645 0.04 19.03 1.37 6.72% BPS 1•N-08 PC2VV ED HORN STROBE,CELM,,WHITE 15CD 0.035 0.159 32 0.199128 0.03 20.13 0.27 1.33% BPS 2•M-05 SCWLID STROBE,CERM,,WIDE 15CD 0.018 0.7A4 9 0.055548 0.01 19.02 1.38 6.77 BPS 1•N2-09 SCWLED STROBE,CERINC,,WHIIE 15CD 0.018 0.17A 19 0.115425 0.01 20.12 0.28 1.40% RPS 2•M•06 SCMED STROBE,CERII Y',WMIE 15CD 0A 0.186 19 0.115965 0.02 19 1.40 6.88 BPS I-M-10 SOWED STROBE,CE M,,WIDE 15CD 0.018 0.106 9 0.053002 0.01 20.11 0.29 1.42% RPS 2•M•07 PC2W ED HORNSTROBE,CERM,WRITE 30CD 0.038 0.168 20 0.124434 0.02 18.98 1.42 6.98% BPS I-M-11 PC2WIED HORN STROBE,CERM,WRITE 15CD 0.035 0.088 17 0.106057 0.01 20.10 0.3 1.47% RPS 2•M-08 SCVVUED STROBE,CERII Y',WMIE 15CD 0.018 0.13 17 0.10614 0.01 18.96 1.44 7.05% RPS 1•Nb12 SCWLED STROBE,CERII Y',WMIE 15CD 0.018 0.053 9 0.053689 0 20.10 0.3 1.48% RPS 2•M-09 SCVVUED STROBE,CERM,,WHDE 15CD 0.018 0.112 12 0.076579 0.01 18.95 1.45 7.09% BPS I•NL•13 FOL4.7K PC2VVED FORNSTROBE,CELM WIDE 15CD 0.035 0.035 17 0.105427 0 20.09 0.31 1.50% RPS 2•M•10 PC2WIID FpRNS1ROLE,CERAG,WHITE 30CD 0.038 0.094 IS 0.094997 0.01 18.94 1.46 7.14% CALCUTATIONioETHODS: RPS2•M•11 PC2WIID HORNSTROBE,CEILING',WI-IIIE 39 0..8 0.056 31 0.1.8 0.01 18.93 1.47 7.19% RESISTRCEFROMPREVIOUS(Q WIRE RESISTANCE(0"X2 XDIST FROMPREVIOUS(ED BPS 2•Ni•12 EOL4.7K SCVVUED STROBE,CEILING,WMIE 15CD 0.018 0.018 19 0.117338 0 18.93 1.47 7.20% DATE: 04.09.2025 VOLTAGE DROP FROMPREVIOUS=RESISTANCE FROMPREVIOUS(fry XREPAT-Du CURRENT(A) GALCIIIATIONivETHODS: RESISTANTFROMPREVLOLT(0)=WRE RESISTANCE(aFT)X2 XIIST.FROMPREVIOUS TD CURRENT SUM4IARY POWER SUMMARY VOLTAGE DROP FROMPREVIOUS=RESISTANCE FROMPREVIC 6(S�XREMAIMK'CURRENT(A) TOEALCIRCUITCURRENT (A), 0.37 STARTMCALC. 20.40 MIX VOLTAGE DROP: 0.610 CIRRENr SLAt"Y POWER SUbMARY MAX CI RCUH'CURRENE SPARE CIRCUIT VOLTAGE: TUEALCIRCUTCURRENT 3 2.63 VOLTAGE DROP%: 3.01°o (A), 0.265 STARTMCAIC MIX VOLTAGE DROP: 0.49 Q RPS 1 N POINT-74PO1M'REPORT (A): CURRENT(A): SPARE CIRCUIT MN OPERATIONAL MAX CRCLrr CURBINT SPARE CIRCUIT VOLTAGE: 20.40 CRRIM,%, 87.67% VOLTAGE: 16 ENDOF IIIJEVOLTAGE: 19.79 BPS 2 M POEVE-TO-POINTRFPORT (A): 3 CURRENT(A): 2.74 VOLTPGEDROP%: 238% J M TUTALCARDC[RREN TOTAL CIRCUIT LENYiTH SPARE CIRCUIT MN.OPERATIONAL J N JAL (A), 1.52 WIRE RESISTANCE 3.07 (FT). 400 CRREN'%, 91.17% VOLTAGE: 16 END TAGS: 19.91 m N SPARE CARDCIRRENr LaITI): TOTALCRCUIT TOTALCARDCURRENT TOTALCIRCUITDENN711 LLI 00 CRCURWIRI4G PROPERTIES:'A 142}PIP/R(NM)14 AMC,2COND.SOIIDCOPPER FPIP/RANA[GG UIVSIIEIDED MAX CARDC[RRENT(A>): Na 2.46 1.18 388 _ 00 (/): RESISTANCE(f): (E): WIRE RESISTANCE (FI): Z SPARE CARDCURRENT SPARE CARD CURRENT (Q); 3.07 TOTALCIRCLET Q D15TN4CEbP.ASIRIDUSING LIP.WN SEGIvENTLII4CiHS W71H 10.00%ADDIIIONALLIIJCIIHCALCUfATFD %, CIRCUIT ARINGPROPERTIFS:'A 142 FPIP/R(NAL)14AWO,2CONE,SOLID COPPER FPIP/RAWILOGUNSH[EDED MAX CARDCURRENT(A>): Na 2.38 Q REM%INNO ALARM DISTANCE FROM RESISTANCEFROM VOLTAGE DROP FROM VOLTAGE DROP RD RESISTANCE(f2): Y IL DEVICE LABEL PARTNO DESCRIPTION CANDELAS ALARMC[RREN'(A) VOLTAGE ATIEMCE TOTAL VOLTAGEIROP DISTX4CE MEASLRED USING DRAWNSECINENTLENOHS WITH 10.00%ADDITIONAL L2,UTHCALCULAIID SPARE CARDCURRINT CURREM'(A) PREVIOUS PREVIOUS(dd) PREVIOUS PERCENT %. a } Z BPS 1•M-01 PC2VVED TURN STROBE,CELM,,WHITE 15CD 0.035 0.37 150 0.9210 0.34 20.06 0.34 1.67% REMAINN:ALARM DISTANCE FROM RESLSTANICEFROM VOLTAGE DROP FROM VOLTAGE DROP d LU DEVICE LABEL PARTNO DESCRIPTION CANDELAS AIARMC[RRENC(A� VOLTAGE AT DEVICE TOTAL VOLTAGEIROP Q RPS 1•N-02 SCWDID STROBE,CERM,WHITE 15CD 0.018 0.335 31 0.188499 O.11b 20 0.4 1.98% CURREM'(A) PREVIOUS PREVIOUS(fI) PREVIOUS PERCEN' � Y BPS 1•M•03 PC2WIED HORNSTROBE,CERM,WMIE 75CD 0.087 0.317 14 0.086245 0.03 19.97 0.43 2.11% BPS 2-M-01 SCVVUED STROBE,CEILING,WMIE 15CD 0.018 0.265 205 1.26 0.33 20.07 0.33 1.64% Q BPS 1•M•04 SCWLED STROBE,CEILING,WMIE 15CD 0.018 0.23 24 0.149617 0.03 19.93 0.47 2.28% BPS 2•N4-02 PC2WIPD BORN STROBE,CELM,,WHITE 15CD 0.035 0.247 23 0.141537 0.03 20.03 0.37 L81% J Z BPS 1•M-05 PC2VV ED HORNSTROBE,CELM,,WHITE l5CD 0.035 0.212 38 0.235496 0.05 19.88 0.520 2.53% BPS 2-M-03 PC2WIED BORN STROBE,CELM,,WHITE 15CD 0.035 0.212 21 0.131941 0.03 20 0.4 1.94 BPS 1•M-06 PC2VV ED TURN STROBE,CELM,,WHITE 15CD 0.035 0.177 41 0.251072 0.04 19.84 0.560 2.75% BPS 2-M-04 SCWIID STROBE,CEILING,WMIE 15CD 0.018 0.177 I8 0.108044 0.02 19.98 0.42 2.04% J BPS 1•M•07 SOWED STROBE,CERM,,WIDE 15CD 0.018 0.142 27 0.163636 0.02 19.82 0.580 2.86% BPS 2-M-05 SCWLID STROBE,CEIDIO,WMIE 15CD 0.018 0.159 20 0.125671 0.02 19.96 0.44 2.14% BPS 1•M•08 P(2WIID HORNSTRDEE CEQINC,WMIE 15CD 0.035 0.17A 15 0.091956 0.01 19.81 0.590 2.92% BPS 2•M-06 PC2WIFD HORN STROBE,CERM,WMIE 15CD 0.035 0.141 12 0.070899 0.01 19.95 0.45 2.18% BPS 1•M.09 SCWLED STROBE,CEILING,WMIE 15CD 0.018 0.089 9 0.053879 0 19.80 0.60 2.94% BPS 2•NM4T7 SCVVUED STROBE,CERM,,WHIIE 15CD 0.018 0.106 26 0.159842 0.02 19.94 0.46 2.27% �••� Cfl BPS 1•N•10 SCWDED STROBE,CEIM WHIIE 15CD 0.018 0.071 19 0.115142 0.01 19.79 0.610 298% BPS 2•N4-08 PC2W ED HDRNSTROBE,CEUNQ WHITE 15CD 0.035 0.088 22 0.135559 0.01 19.93 0.47 2.33 BPS 1•N•11 PC2WIED HDRNSTROBE,CERAG,WHITE 15CD 0.035 0.053 16 0.099969 0.01 19.79 0.610 3.00% BPS 2-M-09 SCWLID STROBE,CEILING,WMIE 15CD 0.018 0.053 25 0.152781 0.01 19.922.37 RPS 1•N3.12 EOL4.7K SCWDID STROBE,CEILING,WMIE 15CD 0.018 0.018 16 0.101191 0 19.79 0.610 3.01% BPS 2•N4.10 EOL4.7K PC2WIID HORN STROBE,CEQINC,WMIE I5CD 0.035 0.035 16 0.097814 0 19.91 6.41 2.38% CALCUTATIONAETHODS: CALCULATIONhETHOD6: RESLSTANCEFROMPREVLOUS(0)=WRERESISTANCE(aFT)X2 XIIST.FROMPREVIOLS(FT) RESISTANCE FROMPREVLOUS(f2)-WIRE RESISTANCE(QFT)X2 XIIST.FROMPREVIOUS(FT) VOLTAGE DROP FROMPREVTOUS=RESISTANCE FROMPREVTOUS(G)XREMARM CIRRENT(AA) VOLTAE DROP FROMPREVIOUS=RESISTANCE FROMPREVIOLS(P XREIMR-PU CURRENT'(,') SHEET TITLE City of Arlington FIRE ALARM POINT TO POINT Building Department VOLTAGE DROP POINT TO POINT VOLTAGE DROP CALCULATIONS APPROVED CALCULATIONS Kevin Olander- 05/01/2025 SHEET NUMBER No changes authorized unless approved by the Building Official FA 5.0 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 _ BUILDING PERMIT 16410 SMOKEY POINT BLVD STE 101 Permit#:6460 Parcel#:31052900100800 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:FULL BUILDING FIRE ALARM SYSTEM UPGRADE Valuation:20000.00 _ APPLICANT CONTRACTOR SMOKEY POINT PROFESSIONAL FIRE PROTECTION INC FIRE PROTECTION INC GROUP LLP 1505 E 5TH ST 17410 ASH WAY 1730 Gibson Rd ARLINGTON,WA 98223-1125 LYNNWOOD Everett,WA 98204 4252909600 425-290-9600 LIC:601848 346 EXP:01/31/2026 LIC:FRUTI*021ML EXP:07/13/2026 MECHANICAL CONTRACTOR ' PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2021 STORIES: 3 CONST.TYPE: VA DWELLING UNITS: 0 OCC GROUP: B;Business BUILDINGS: I OCC LOAD: ' PERMIT APPROVAL _ The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Digitally signed by Nick Chandler DN:—Nick Chandler,-US, email=nick.05.05 09:34om 0 5/0 5/2 0 2 5 G�..Gr�..����/��- OT00'2025.05.05 09:34:28- 05�05�2025 Applicant Signature Date Building Official Date ■ CONDITIONS I Adhere to the approved plans.Approved plans and signed permit shall be onsite for inspections.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/05/2025 Web Only-Fire System Plan Review $200.00 05/05/2025 Credit Card Service $6.00 05/05/2025 Processing/Technology $25.00 05/05/2025 Fire Plarm System Permit $475.00 Total Due: $706.00 Total Payment: $706.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail From: Jackie Mow To: Hannah Hardwick Subject: RE: BLD6460-Permit Expiration Notice Date: Wednesday,October 15,2025 10:26:27 AM Attachments: image004.ong imaae005.una image006.ona image007.1)na This message is from an External Sender This message came from outside the City of Arlington Hello, We received the notice below and would like to request an extension on this permit. Work is still ongoing and not ready for inspection. We expect to complete the project over the next few weeks. Please let me know if you need anything else from us to extend this permit. Thank you in advance, Jackie Mow Installations Manager �7 AV Fire Protection, Inc. — Washington's Most Trusted Name in Fire Safety Since 1968 17410 Ash Way, Suite 8 Lynnwood, WA 98037 jackie(@fpiseattle.com p:(425) 290-9600 f: (425) 787-9705 www.FPISEATTLE.com Fire Alarm • Sprinkler • Security • Access Control • CCTV • ERRC • Extinguisher • Kitchen Hoods Monitoring • Installation • Service • Inspections Optimize your support experience by contacting our specialized teams through these dedicated inboxes: Service InspectionsP Sales Billin From: Hannah Hardwick<hhardwick(@arlingtonwa.gov> Sent: Friday, September 26, 2025 1:23 PM To: Nick Chandler<nick(@fpiseattle.com> Subject: BLD6460- Expiration Notice Hello, This email is to inform you of the upcoming expiration date for permit 6460.This permit will expire on 10/31/2025. Please ensure that an inspection has been requested and approved prior to the expiration date. If you are not ready an inspection prior to the expiration date, please reply requesting an extension. The request needs to state cause for the extension and requires approval by the Building Official once received.Additional fees may be required upon extension approval. Please use the link below to view and request an inspection.You can also call in an inspection at 360-403-3417. Permits -Arlington (iworq.net) Sincerely, I I Hannah Hardwick Community&Economic Development Fire Permit Technician 11 18204 59th Ave NE,Arlington,WA 98223 O:360.403.3549 hhardwickParlingtonwa.goy I www.arlingtonwa.gov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act.