Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16512 51ST AVE NE_BLD6497_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16512 51ST AVE NE Permit#:6497 PERMIT EXPIRES 180 DAYS AFTER Parcel#:31052800101000 DATE OF ISSUANCE. Scope of Work:Installing new fire sprinkler systern,adding 5 wet systems,I diesel Valuation:293125.00 fire pump,and 2007 sprinkler heads OWNER APPLICANT CONTRACTOR SINGH H/LALLI I/DHILLON D/S/R K AFP Systems,Inc AFP Systems Inc 8520 79TH AVE NE 19435 SW 129th Ave 19435 SW 129th Ave MARYSVILLE,WA 98270 Tualatin,OR 97062 Tualatin,OR 97062 5036929284 503-692-9284 1.10 601 290 341 EXP:07/31/2026 IUC:AFPSYI*091BZ EXP:10/17/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2021 STORIES: 1 CONST.TYPE: 111B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. S�p to- 1 .2e) 9 �Zaow i 09/30/2025 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans.Permit shall be onsite for inspection. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/30/2025 Fire System Plan Review $2,034.03 09/30/2025 Credit Card Service $61.02 09/30/2025 Prooessing/Technology $25.00 09/30/2025 Fire Sprinlder System $3,257.00 09/30/2025 Credit Card Service $98.46 Total Due: $5,475.51 Total Payment: $5,475.51 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Faiil FIRE SPRINKLER PERMIT APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Type of Permit: E] New Installation C] System Modification ❑ Phased Installation Property Address: ale. LC-- Suite No.: Project Valuation:`2 6f 3 Lot#: Parcel ID No.: �1U S 2-30 C 1 O(-7 00 Preferred Contact: ❑ Owner JqApplicant 52 pp 0 6 O Contractor Project Description: =r,S,(-pill; r&k&) JPirz -sP►'in�-- Us- S'�S-rQm, amirlg b NJ Qt d f v5 e- J'o� PurnP , orcl 200 ,S I-J el h e&d Owner Name: 9 �-e e1\4r G►rO�J� Phone No.: 20(0.20 CIL -CCEmail Address: Cell No.: Sfia go 52a ��� MailingAddress: t-i()b v � 1 LL State: Zi Applicant Name: K A i<LL�n She U_ C� Phone No.: Gl2 Email Address: Fy m ;Ls Cell No.: day 3S Sw Ci : Uq c, State:01� Zi 47d Z_ Mailing Address: Contractor Name: iA P S Office No.: Email Address: P��w,,'�5 0.� . CUrr1 Cell No.: Mailing Address: [J1J3CD S -(ice City: TUa&Ajf�. State: a _ Zip:pO L&I Contractor License Number: L" Expiration Date: SUBMITTAL REQUIREMENTS:Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: Complete and Scaled Plans 10 Hydraulic Calculations Equipment Specifications for Each Fire Sprinkler Permit Application Specification Sheets Q Wiring Diagrams(Point to Point Wiring) Q Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) **DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers,Valves, Pull Stations,and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than$5,000.00 =$100.00 $5,000.00&over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application -review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection(1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 TENANT IMPROVEMENT OR SYSTEM MODIFICATION(NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.00 + Is = $ Hydraulically Designed Systems Yes ❑ / No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $62S.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $625.00 + Is I = $ Hydraulically Designed Systems Yes ❑ / No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ❑ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% _ $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 Q HOOD SUPPRESSION SYSTEM Type of System No.of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No.of Units Cost per Unit Subtotal Class I-new or existing x $150.00 = $ Class II-new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ 3D FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No.of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that 1 am the ❑Owner, 5 Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 1 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 100ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1727.11 @ 62.080 (Safety Margin = 14.094) from Pump at Node: 1: 1477.11 @ 138.216 (Safety Margin = 14.094) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS , Brandon James Stewart `cQ , ' 3259-0615-C-H Leve13 N , AFP Systems,Inc. o AFPSYI'091BZ �o , Signature 12/31/25 , ---------------------------' �©M.E.P.CAD �AutoSPRINK 2024 v19.0.46.0 1 3/31/2025 9:59:53AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(1) Remote Area Number:1 100 3A 82 3B 3 64 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Data nt Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:62.080 @ 1477.11 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):62.080 @ 1727.11 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.175 @ 1727.11 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 "n ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:59:55AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(1) Remote Area Number:1 200 7A 172 7B 144 • 1B 116 7 5A 88 5B 2A SC N Q 60 2B 5 2C 2D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:138.216 @ 1477.11 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.030 @ 1477.11 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.030 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.030 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.280 @ 1477.11 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.310 @ 1477.11 M[J©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:59:55AM Page 3 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.175 1727.11 62.080 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.310 1477.11 138.216 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 151 0'-0 Supply 62.080 1477.11 601 39'-0 Sprinkler 52.000 121.15 602 39'-0 Sprinkler 52.906 122.20 603 39'-0 Sprinkler 52.127 121.29 604 39'-0 Sprinkler 54.091 123.56 605 39'-0 Sprinkler 52.933 122.23 606 39'-0 Sprinkler 52.128 121.30 607 39'-0 Sprinkler 54.255 123.75 608 39'-0 Sprinkler 54.176 123.66 609 39'-0 Sprinkler 54.360 123.86 610 39'-0 Sprinkler 54.367 123.87 611 39'-0 Sprinkler 55.399 125.04 612 39'-0 Sprinkler 55.546 125.21 1 2'-11'/z P2 138.216 P2(-85.280) 2 39'-0 53.845 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:59:58AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 3 38'-0 59.321 4 38'-0 59.716 5 39'-0 54.781 6 38'-0 58.649 7 38'-0 58.572 8 39'-0 54.809 9 38'-0 63.608 10 38'-0 63.965 11 38'-0 64.064 12 38'-0 98.316 13 38'-0 87.646 14 38'-0 87.997 15 38'-0 87.585 16 38'-0 88.872 17 2'-11'/z Gauge 136.983 18 38'-0 87.614 19 38'-0 98.333 20 38'-0 86.421 21 38'-0 90.767 22 38'-0 86.323 23 38'-0 92.404 24 38'-0 98.384 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:59:58AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 25 38'-0 93.829 26 38'-0 98.482 27 38'-0 88.578 28 38'-0 95.080 29 38'-0 98.628 30 38'-0 96.193 31 38'-0 88.845 32 38'-0 98.822 33 38'-0 97.194 34 38'-0 88.971 35 38'-0 99.058 36 38'-0 98.111 37 38'-0 89.003 38 38'-0 99.329 39 38'-0 98.966 40 38'-0 99.622 41 38'-0 99.786 42 38'-0 99.900 43 38'-0 100.629 44 38'-0 100.149 45 38'-0 101.524 46 38'-0 100.356 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:59:58AM Paqe 6 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 47 38'-0 102.496 48 38'-0 100.518 49 38'-0 103.570 50 38'-0 100.631 51 38'-0 104.773 52 38'-0 109.465 53 38'-0 100.697 54 38'-0 109.258 55 38'-0 110.074 56 38'-0 100.715 57 38'-0 110.423 58 38'-0 109.240 59 38'-0 112.271 60 38'-0 112.196 113 2'-11'/z 138.117 114 2'-11'/z P1 52.935 115 -3'-0'/2 56.466 150 0'-0 61.813 264 38'-0 112.192 265 2'-11'/z 136.614 268 2'-1'/2 54.084 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:59:58AM Paqe 7 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 5'-1'/2 120 52.000 .....Route 1 601 39'-0 16.8 121.15 2 (See Sprinkler, Notes) 13'-7'/2 2 39'-0 121.15 2.2030 0.098242 PO(13'-7'/2) 18'-9'/2 1.845 2 39'-0 117.54 2 (See 1'-0 120 53.845 Flow(q)from Route 2 Notes) 13'-7'/2 0.434 3 38'-0 238.69 2.2030 0.344469 5.043 PO(13'-7'/2) 3 38' 0 4 (See 2'-3 120 59.321 Notes) 27'-10'/2 4 38'-0 238.69 4.3100 30'-1 0.013114 0.395 T(27'-10'/2) 4 38'-0 384.65 4 (See 36'-4 120 59.716 Notes) Flow(q)from Route 4 13'-11 9 38'-0 623.34 4.3100 50'-3 0.077444 3892 E(13'-11) 9 38' 0 2 (See 31'-4 120 63.608 PO(13'-7'/2) Notes) 54'-6'/2 15 38'-0 213.05 2.2030 85'-10'/2 0.279166 23.977 3PO(13'-7'/2) 15 38'-0 4 10'-0'/2 120 87.585 13 38'-0 157.35 4.3100 0.006067 10'-0'/2 0.061 13 38'-0 248.92 4 10'-0 120 87.646 Flow(q)from Route 3 14 38'-0 406.27 4.3100 0.035080 10'-0 0.351 14 38'-0 300.60 4 8'-11'/2 120 87.997 Flow(q)from Route 6 16 38'-0 706.87 4.3100 0.097730 8'-11'/2 0.875 16 38'-0 304.25 4 10'-0 120 88.872 Flow(q)from Route 8 21 38'-0 1011.12 4.3100 0.189512 10'-0 1.895 21 38'-0 4 10'-0 120 90.767 23 38'-0 934.17 4.3100 0.163696 10'-0 1.637 23 38'-0 4 10'-0 120 92.404 25 38'-0 866.64 4.3100 0.142480 10'-0 1.425 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 8 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 25 38'-0 4 10'-0 120 93.829 28 38'-0 808.08 4.3100 0.125181 10'-0 1.252 28 38'-0 4 10'-0 120 95.080 30 38'-0 758.07 4.3100 0.111227 10'-0 1.112 30 38'-0 4 10'-0 120 96.193 33 38'-0 716.33 4.3100 0.100162 10'-0 1.002 33 38'-0 4 10'-0 120 97.194 36 38'-0 682.76 4.3100 0.091652 10'-0 0.917 36 38'-0 4 10'-0 120 98.111 39 38'-0 657.70 4.3100 0.085526 10'-0 0.855 39 38'-0 4 10'-0 120 98.966 41 38'-0 642.77 4.3100 0.081970 10'-0 0.820 41 38'-0 9.71 4 10'-0 120 99.786 Flow(q)from Route 20 43 38'-0 652.48 4.3100 0.084275 10'-0 0.843 43 38'-0 21.74 4 10'-0 120 100.629 Flow(q)from Route 30 45 38'-0 674.22 4.3100 0.089543 10'-0 0.895 45 38'-0 30.66 4 10'-0 120 101.524 Flow(q)from Route 31 47 38'-0 704.87 4.3100 0.097220 10'-0 0.972 47 38'-0 38.93 4 10'-0 120 102.496 Flow(q)from Route 28 49 38'-0 743.80 4.3100 0.107385 10'-0 1.074 49 38'-0 47.16 4 10'-0 120 103.570 Flow(q)from Route 29 51 38'-0 790.96 4.3100 0.120319 10'-0 1.203 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 9 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 51 38'0 55.63 4 (See 6-6 120 104.773 Flow(q)from Route 35 Notes) 2T-10'/2 52 38'-0 846.59 4.3100 34'-4'/2 0.136441 4.691 T(27'-10'/2) 52 38'-0 164.53 6 2V-4 120 109.465 Flow(q)from Route 15 55 38'-0 1011.12 6.3570 0.028556 21'-4 0.609 55 38'-0 116.14 6 10'-0 120 110.074 Flow(q)from Route 11 57 38'-0 1127.27 6.3570 0.034919 10'-0 0.349 57 38'-0 116.39 6 (See 6'-4'/2 120 110.423 Flow(q)from Route 12 Notes) 37'-8'/2 59 38'-0 1243.66 6.3570 0.041880 T(37'-8'/2) 44'-1'/2 1.847 59 38'-0 233.46 6 (See 38'-4 120 112.271 Flow(q)from Route 10 Notes) 120'-8'/2 15.187 265 2'-11'/2 1477.11 6.3570 159'-0'/2 0.057575 9.156 2E(17'-7),CV(47'-9'/z), PO(37'- 8'/2) 265 2'-11'/2 8 (See T-6'/2 120 136.614 Notes) 15'-3 0.000 17 2'-11'/2 1477.11 8.2490 22'-9'/2 0.016188 0.369 fE(15'-3), BOR 17 2'-11'/2 8 (See T-1 120 136.983 Notes) 66' 11'/2 -0.000 113 2'-11'h 1477.11 8.2490 70' 0.016188 1.134 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 V-8'/2 120 138.117 0.000 1 2'-11'/2 1477.11 6.3570 0.057575 1'-8'h 0.099 1 1477.11 Pump 138.216 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5'-4 120 52.935 Notes) 43'-5'/2 0.359 0.016188 GV(4'-8'/2),fT(38'-9) 268 2'-1/2 1477.11 8.2490 48'-9'/2 0.790 268 2'-1'/2 10 (See 5'2 120 54.084 Notes) 20'-1 2.247 115 -T-0'/2 1477.11 10.3700 0.005312 E(20'-1) 25'-3/2 0.134 L{/©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 10 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 115 -3'0'/z 10 (See 176'-7 140 56.466 Notes) 149'-10'/z -1.319 150 0'-0 1477.11 10.4000 326'-5%2 0.003938 6.667 2E(35'-1),BFP(-5.382),T(79'- 8'/2) 150 0'-0 E12.4600 (See 119'-2'/2 140 61.813 Notes) 44'-3 151 0'-0 1477.11 163'-5 0.267 0.001633 S, E(44'-3) 250.00 62.080 Hose Allowance At Source 151 1727.11 Total(Pt) Route 1 4'-10'/z 120 52.127 •••••Route 2••••• 603 39'-0 16.8 121.29 2 (See Sprinkler, Notes) 1 ' '1 3 7 2 39'-0 117.54 2.2030 18'-6 0.092898 1.718 PO(13'-7'/z) 53.845 Total(Pt) Route 2 8'-0 120 52.127 •••••Route 3••••• 603 39'-0 16.8 121.29 2 (See Sprinkler Notes) 606 39'-0 3.76 2.2030 0.000159 8'-0 0.001 606 39'-0 16.8 121.30 2 (See 71-10 120 52.128 Sprinkler, Notes) 13'-7'/z 610 39'-0 125.05 2.2030 21' 6 0.104180 2.239 2E(6'-10) 610 39' 0 16.8 123.87 2 (See 33'-8 120 54.367 Sprinkler, Notes) 54'-6'/z 0.434 13 38'-0 248.92 2.2030 88'-2'/z 0.372305 32.845 4PO(13'-7'/z) 87.646 Total(Pt) Route 3 5'-1'/2 120 52.906 •••••Route 4••••• 602 39'-0 16.8 122.20 2 (See Sprinkler, Notes) 13'-7'/2 5 39'-0 122.20 2.2030 18'-9'/2 0.099825 1.875 PO(13'-7A) 5 39'-0 71.75 2 (See 1'-0 120 54.781 Flow(q)from Route 7 Notes) 13'-7'/2 0.434 6 38'-0 193.95 2.2030 0.234633 3.435 PO(13'-7A) 6 38'-0 190.71 4 (See 5'-9'/z 120 58.649 Flow(q)from Route 5 Notes) 27'-10'/2 4 38'-0 384.65 4.3100 33 8 0.031705 1.067 T(27'-10'/z) 59.716 Total(Pt) Route 4 �{ ©M.E.P.CAD A]AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 11 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 5'-1'/2 120 52.933 .....Route 5 605 39'-0 16.8 122.23 2 (See Sprinkler, Notes) 13'-7'/2 8 39'-0 122.23 2.2030 0.099872 PO(13'-7'/2) 18'-9'/2 1.876 8 39'-0 68.48 2 (See 1'-0 120 54.809 Flow(q)from Route 9 Notes) 13'-7'/2 0.434 7 38'-0 190.71 2.2030 0.227430 3.329 PO(13'-7'/2) 7 38'-0 4 8'-11'/2 120 58.572 6 38'-0 190.71 4.3100 0.008658 8'-11/2 0.078 58.649 Total(Pt) Route 5 604 39'-0 16.8 123.56 2 (See 8'-0 120 54.091 •••••Route 6••••• Notes) Sprinkler 607 39'-0 51.81 2.2030 0.020409 8'-0 0.163 607 39'-0 16.8 123.75 2 (See 5'-10'/2 120 54.255 Sprinkler Notes) 611 39'-0 175.55 2.2030 0.195133 5'-10'/2 1.144 611 39'-0 16.8 125.04 2 (See 33'-8 120 55.399 Sprinkler, Notes) 27'-3'/2 0.434 14 38'-0 300.60 2.2030 0.527769 2P0(13'-7'/2) 60'-11'/2 32.164 87.997 Total(Pt) Route 6 604 39'-0 16.8 123.56 2 (See 4'-10'/2 120 54.091 •••••Route 7••••• Notes) 13'-7 Sprinkler, '/2 5 39'-0 71.75 2.2030 18'-6 0.037277 0.689 PO(13'-7'/2) 54.781 Total(Pt) Route 7 8'-0 120 54.176 •••••Route 8••••• 608 39'-0 16.8 123.66 2 (See Sprinkler Notes) 609 39'-0 55.18 2.2030 0.022932 8'-0 0.183 609 39'-0 16.8 123.86 2 (See 5'-10'/2 120 54.360 Sprinkler Notes) 612 39'-0 179.04 2.2030 0.202369 5'-10'/2 1.187 612 39'-0 16.8 125.21 2 (See 33'-8 120 55.546 Sprinkler, Notes) 27'-3'/2 0.434 16 38'-0 304.25 2.2030 0.539705 2PO(13'-7'/2) 60'-11'/2 32.892 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 12 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 88.872 I Total(Pt) Route 8 608 39'-0 16.8 123.66 2 (See 4'-10'/2 120 54.176 •••••Route 9••••• Sprinkler, Notes) 13'-7'/2 8 39'-0 68.48 2.2030 18'-6 0.034193 0.632 PO(13'-7'/2) 54.809 Total(Pt) Route 9 7'-6'/z 120 112.192 •••••Route 10••••• 264 38'-0 116.47 6 Flow(q)from Route 14 60 38'-0 116.47 6.3570 0.000524 7'-6/2 0.004 1'-7'/ 196 z 120 112. 60 38'-0 116.98 6 (See Flow(q)from Route 13 Notes) 13 7'8'1 59 38'-0 233.46 6.3570 39 4 0.001897 0.075 T(37'-8'/z) 112.271 Total(Pt) Route 10 22 38'-0 204.66 4 10'-0 120 86.323 .....Route 11 Flow(q)from Route 18 20 38'-0 204.66 4.3100 0.009866 10'-0 0.099 20 38'-0 205.63 4 (See 5-6 120 86.421 Flow(q)from Route 17 Notes) 27'-10'/2 18 38'-0 410.29 4.3100 33'-4'/2 0.035724 1.193 T(27'-10'/2) 18 38'-0 55.70 4 21'-4 120 87.614 Flow(q)from Route 19 27 38'-0 465.99 4.3100 0.045211 21'-4 0.965 27 38'-0 2 (See 182'-0 120 88.578 Notes) PO(13'-7'/z) 54'-6'/2 0.000 55 38'-0 116.14 2.2030 0.090870 3PO(13'-7'/2),Z 236'-6'/2 21.495 110.074 Total(Pt) Route 11 27 38'-0 116.14 4 10'-0 120 88.578 .....Route 12 Flow(q)from Route 11 31 38'-0 349.85 4.3100 0.026602 10'-0 0.266 31 38'-0 2 (See 182'-0 120 88.845 Notes) 54'-6'/2 0.000 0.091222 2PO(13'-7'%),T(13'-7'%) 57 38' 0 116.39 2.2030 236'6'/2 21.579 110.423 Total(Pt) Route 12 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 13 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) Foot) (psi) Friction(Pf) directly to(Pf)and shown as ( 31 38'-0 116.39 4 10'-0 120 88.845 .....Route 13 Flow(q)from Route 12 34 38'-0 233.46 4.3100 0.012587 10'-0 0.126 34 38'-0 2 (See 184'-0 120 88.971 Notes) 68'-2 2 0.000 0.092090 3PO(13'-7'/z),2E(6'-10) 60 38'-0 116.98 2.2030 252'-2'/2 23.225 112.196 Total(Pt) Route 13 34 38' 0 116.98 4 9'-2'/2 120 88.971 •••••Route 14••••• Flow(q)from Route 13 37 38'-0 116.47 4.3100 0.003477 9'-2'h 0.032 37 38'-0 2 (See 185-8 120 89.003 Notes) 68'-2,/z 264 38'-0 116.47 2.2030 0.091346 3PO(13'-7'/z),2E(6'-10) 253' 10/z 23.189 112.192 Total(Pt) Route 14 54 38'-0 82.17+82.36 4 (See 3'-6 120 109.258 .....Route 15 Flow(q)from Route 16 and Notes) 27'-10'/z 32 52 38'-0 164.53 4.3100 31'-4'/z 0.006589 0.207 T(27'-10'/z) 109.465 Total(Pt) Route 15 58 38'-0 82.17 4 10'-0 120 109.240 .....Route 16 Flow(q)from Route 33 54 38'-0 82.17 4.3100 0.001824 10'-0 0.018 109.258 Total(Pt) Route 16 9 38'-0 213.05 4 10'-0 120 63.608 .....Route 17 Flow(q)from Route 1 10 38'-0 410.29 4.3100 0.035724 10'-0 0.357 10 38'-0 2 (See 31'-4 120 63.965 Notes) 54'-6'/2 20 38'-0 205.63 2.2030 0.261456 3PO(13'-7'/z) 85'-10'/2 22.456 86.421 Total(Pt) Route 17 10 38'-0 205.63 4 10'-0 120 63.965 .....Route 18 Flow(q)from Route 17 11 38'-0 204.66 4.3100 0.009866 10'-0 0.099 LM ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 14 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 11 38'0 2 (See 31'-4 120 64.064 PO(13'-7'/2) Notes) 54'-6'/z 22 38'-0 204.66 2.2030 85'-10'/2 0.259158 22.259 3PO(13'-7'/z) 86.323 Total(Pt) Route 18 15 38'-0 157.35 4 (See 4'-6 120 87.585 .....Route 19 Notes) 27'-10'/2 Flow(q)from Route 1 18 38'-0 55.70 4.3100 0.000888 T(27'-10'/z) 32'-4/20.029 87.614 Total(Pt) Route 19 123'-4'/z 120 93.829 .....Route 20 25 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 24 38'-0 58.57 2.2030 177'-11 4.556 0.025604 3PO(13'-7'/z) 24 38'-0 144.48 4 10'-0 120 98.384 Flow(q)from Route 23 26 38'-0 203.05 4.3100 0.009723 10'-0 0.097 26 38'-0 50.01 4 10'-0 120 98.482 Flow(q)from Route 24 29 38'-0 253.05 4.3100 0.014611 10'-0 0.146 29 38'-0 41.74 4 10'-0 120 98.628 Flow(q)from Route 27 32 38'-0 294.80 4.3100 0.019380 10'-0 0.194 32 38'-0 33.57 4 10'-0 120 98.822 Flow(q)from Route 21 35 38'-0 328.37 4.3100 0.023660 10'-0 0.237 35 38'-0 25.06 4 10'-0 120 99.058 Flow(q)from Route 22 38 38'-0 353.43 4.3100 0.027108 10'-0 0.271 38 38'-0 14.92 4 10'-0 120 99.329 Flow(q)from Route 26 40 38'-0 368.35 4.3100 0.029264 10'-0 0.293 40 38'-0 2 (See 123'-4'/z 120 99.622 Notes) 54'-6'/z 41 38'-0 9.71 2.2030 177'-11 0.164 0.000921 3 PO(13'-7'/z) 99.786 Total(Pt) Route 20 LM ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 15 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 123'-4'/2 120 97.194 •••••Route 21 ••••• 33 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/2 32 38'-0 33.57 2.2030 177'-11 1.627 0.009145 3PO(13'-7'/2) 98.822 Total(Pt) Route 21 36 38'-0 2 (See 123'-4'/2 120 98.111 •••••Route 22••••• Notes) 54'-6 PO(13'-7'/2) '/2 35 38'-0 25.06 2.2030 177'-11 0.947 0.005324 3PO(13'-7'/2) 99.058 Total(Pt) Route 22 123'-4'/2 120 90.767 .....Route 23 21 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/2 12 38'-0 76.95 2.2030 177'-11 7.550 0.042430 3PO(13'-7'/2) 12 38'-0 4 10'-0 120 98.316 19 38'-0 76.95 4.3100 0.001615 10'-0 0.016 19 38'-0 67.53 4 10'-0 120 98.333 Flow(q)from Route 25 24 38'-0 144.48 4.3100 0.005181 10'-0 0.052 98.384 Total(Pt) Route 23 28 38'-0 2 (See 123'-4'/2 120 95.080 .....Route 24 Notes) PO(13'-7'/2) 54'-6'/2 26 38'-0 50.01 2.2030 177'-11 3.401 0.019116 3PO(13'-7'/2) 98.482 Total(Pt) Route 24 123'-4'/2 120 92.404 .....Route 25 23 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/2 19 38'-0 67.53 2.2030 177'-11 5.929 0.033321 3PO(13'-7'/2) 98.333 Total(Pt) Route 25 39 38'-0 2 (See 123'-4'/2 120 98.966 .....Route 26 PO(13'-7'/2) Notes) 54'-6'/2 38 38'-0 14.92 2.2030 177'-11 0.363 0.002041 3PO(13'-7'/2) 99.329 Total(Pt) Route 26 30 38'-0 2 (See 123'-4'/2 120 96.193 •••••Route 27••••• Notes) 54'-6'/2 29 38'-0 41.74 2.2030 177'-11 2.435 0.013686 3PO(13'-7'/2) �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 16 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 98.628 I Total(Pt) Route 27 123'-4'/2 120 100.356 •••••Route 28 46 38'-0 306.25 2 (See PO(13'-7'/2), Flow(q)from Notes) 54'-6'/z Route 34 177'-11 2.140 47 38'-0 38.93 2.2030 0.012026 3PO(13'-7'/z) 102.496 Total(Pt) Route 28 46 38'-0 306.25 4 10'-0 120 100.356 .....Route 29 Flow(q)from Route 34 48 38'-0 267.32 4.3100 0.016172 10'-0 0.162 123'-4'/z 120 100.518 48 38'-0 2 (See PO(13'-7'/z) Notes) 54'6'/z 49 38'-0 47.16 2.2030 0.017152 3PO(13'-7'/z) 177'-11 3.052 103.570 Total(Pt) Route 29 40 38'-0 9.71 4 10'-0 120 99.622 .....Route 30 Flow(q)from Route 20 42 38'-0 358.64 4.3100 0.027853 10'-0 0.279 42 38'-0 2 (See 123'-4'/2 120 99.900 Notes) 54-6 PO(13'-7'/z) ' '/z 43 38'-0 21.74 2.2030 0.004092 3PO(13'-7'/z) 177'-11 0.728 100.629 Total(Pt) Route 30 42 38'-0 21.74 4 10'-0 120 99.900 .....Route 31 Flow(q)from Route 30 44 38'-0 336.90 4.3100 0.024811 10'-0 0.248 44 38'-0 2 (See 123'-4'/2 120 100.149 Notes) 54'-6'/2 45 38'-0 30.66 2.2030 0.007730 3PO(13'-7'/z) 177'-11 1.375 101.524 Total(Pt) Route 31 123'-4'/2 120 100.697 .....Route 32 53 38'-0 164.53 2 (See PO(13-7'/z), Flow(q)from Notes) 54'-6'/z Route 36 54 38'-0 82.36 2.2030 177'-11 8.561 0.048114 3PO(13'-7'/z) 109.258 Total(Pt) Route 32 53 38'-0 164.53 4 10'-0 120 100.697 .....Route 33 Flow(q)from Route 36 56 38'-0 82.17 4.3100 0.001824 10'-0 0.018 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 17 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 56 38'-0 2 (See 123'-4'/2 120 100.715 Notes) 54'-6'/2 58 38'-0 82.17 2.2030 177'-11 8.524 0.047909 3PO(13'-7'/2) 109.240 Total(Pt) Route 33 44 38'-0 30.66 4 10'-0 120 100.149 .....Route 34 Flow(q)from Route 31 46 38'-0 306.25 4.3100 0.020796 10'-0 0.208 100.356 Total(Pt) Route 34 48 38'-0 47.16 4 10'-0 120 100.518 .....Route 35 Flow(q)from Route 29 50 38'-0 220.16 4.3100 0.011293 10'-0 0.113 50 38'-0 2 (See 123'-4'/2 120 100.631 Notes) 54'6'/2 51 38'-0 55.63 2.2030 0.023279 3PO(13'-7'/2) 177'-11 4.142 104.773 Total(Pt) Route 35 50 38'-0 55.63 4 10'-0 120 100.631 .....Route 36 Flow(q)from Route 35 53 38'-0 164.53 4.3100 0.006589 10'-0 0.066 100.697 Total(Pt) Route 36 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 1 3/31/2025 10:00:01AM Page 18 Job Name: North Sound Logistics Remote Area Number: 1 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 1 3/31/2025 10:00:01AM Page 19 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 2 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 95ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1724.75 @ 61.442 (Safety Margin = 14.768) from Pump at Node: 1: 1474.75 @ 137.625 (Safety Margin = 14.768) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: 60.812 Right: 61.679 ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Brandon James Stewart N ' 3259-0615-C-H Leve13 N , AFP Systems,Inc. o ' AFPSYI*091BZ �c , 9 �54ewA4 Expires Signature 12/31/25 , ---------------------------' �©M.E.P.CAD �AutoSPRINK 2024 v19.0.46.0 2 3/31/2025 9:57:51AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(2) Remote Area Number:2 100 3A 82 36 3 64 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Data nt Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:61.442 @ 1474.75 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):61.442 @ 1724.75 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.210 @ 1724.75 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 An ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:57:53AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(2) Remote Area Number:2 200 7A 172 7B 144 • 1B 116 7 5A 88 5B 2A SC N Q 60 2B 5 2C 12D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:137.625 @ 1474.75 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.084 @ 1474.75 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.084 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.084 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.309 @ 1474.75 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.393 @ 1474.75 LM ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:57:53AM Page 3 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.210 1724.75 61.442 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.393 1474.75 137.625 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 151 0'-0 Supply 61.442 1474.75 401 39'-0 Sprinkler 55.773 125.46 402 39'-0 Sprinkler 53.104 122.43 403 39'-0 Sprinkler 53.281 122.63 404 39'-0 Sprinkler 54.864 124.44 405 39'-0 Sprinkler 52.006 121.15 406 39'-0 Sprinkler 52.192 121.37 407 39'-0 Sprinkler 54.871 124.45 408 39'-0 Sprinkler 52.000 121.15 409 39'-0 Sprinkler 52.187 121.36 410 39'-0 Sprinkler 56.035 125.76 411 39'-0 Sprinkler 52.873 122.16 412 39'-0 Sprinkler 53.074 122.39 1 2'-11'/z P2 137.625 P2(-85.309) 17 2'-11'/z Gauge 136.396 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:57AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 113 2'-11'/2 137.526 114 2'-11'/2 P1 52.316 115 -3'-0'/2 55.843 150 0'-0 61.176 152 38'-0 92.688 153 38'-0 92.708 154 38'-0 92.784 155 2'-11'/z 136.060 156 38'-0 92.946 157 38'-0 93.133 158 38'-0 93.347 159 38'-0 93.587 160 38'-0 93.853 161 38'-0 94.147 162 38'-0 94.468 163 38'-0 94.818 164 38'-0 95.198 165 38'-0 95.610 166 38'-0 97.495 167 38'-0 97.213 168 38'-0 97.171 169 38'-0 97.160 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:57AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 170 39'-0 84.093 171 39'-0 83.971 172 39'-0 83.209 173 39'-0 79.788 174 38'-0 84.669 175 38'-0 84.671 176 38'-0 84.677 177 38'-0 84.709 178 38'-0 84.861 179 38'-0 85.365 180 38'-0 86.405 181 38'-0 87.288 182 38'-0 88.032 183 38'-0 88.656 184 38'-0 89.173 185 38'-0 89.595 186 38'-0 89.932 187 38'-0 90.193 188 38'-0 90.386 189 38'-0 90.521 190 38'-0 90.604 191 38'-0 90.644 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:57AM Paqe 6 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 192 38'-0 90.654 526 2'-1'/2 53.462 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:57AM Paqe 7 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 10'-0 120 52.000 .....Route 1 408 39'-0 16.8 121.15 2 (See Sprinkler Notes) 405 39'-0 7.51 2.2030 0.000572 10'-0 0.006 405 39'-0 16.8 121.15 2 (See 10'-0 120 52.006 Sprinkler Notes) 402 39'-0 128.66 2.2030 0.109809 10'-0 1.098 402 39'-0 16.8 122.43 2 (See 76'-3 120 53.104 Sprinkler, Notes) 2T-3'/z 0.434 153 38'-0 251.08 103'-6'/2 2.2030 0.378303 39.171 2PO(13'-7'/z) 153 38'-0 241.61 6 10'-0 120 92.708 Flow(q)from Route 5 154 38'-0 492.70 6.3570 0.007552 10'-0 0.076 154 38'-0 250.73 6 10'-0 120 92.784 Flow(q)from Route 3 156 38'-0 743.43 6.3570 0.016166 10'-0 0.162 156 38'-0 62.39 6 10'-0 120 92.946 Flow(q)from Route 25 157 38'-0 805.82 6.3570 0.018765 10'-0 0.188 157 38'-0 58.71 6 10'-0 120 93.133 Flow(q)from Route 26 158 38'-0 864.53 6.3570 0.021373 10'-0 0.214 158 38'-0 55.77 6 10'-0 120 93.347 Flow(q)from Route 15 159 38'-0 920.30 6.3570 0.023993 10'-0 0.240 159 38'-0 53.56 6 10'-0 120 93.587 Flow(q)from Route 24 160 38'-0 973.86 6.3570 0.026640 10'-0 0.266 160 38'-0 52.07 6 10'-0 120 93.853 Flow(q)from Route 17 161 38'-0 1025.93 6.3570 0.029335 10'-0 0.293 161 38'-0 51.29 6 10'-0 120 94.147 Flow(q)from Route 19 162 38'-0 1077.22 6.3570 0.032105 10'-0 0.321 �{ ©M.E.P.CAD 411 AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 8 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 162 38'-0 51.19 6 10'-0 120 94.468 Flow(q)from Route 18 163 38'-0 1128.41 6.3570 0.034985 10'-0 0.350 163 38'-0 51.73 6 10'-0 120 94.818 Flow(q)from Route 16 164 38'-0 1180.14 6.3570 0.038010 10'-0 0.380 164 38'-0 52.85 6 10'-0 120 95.198 Flow(q)from Route 2 165 38'-0 1232.99 6.3570 0.041218 10'-0 0.412 165 38'-0 54.48 6 (See 4'-6 120 95.610 Flow(q)from Route 20 Notes) 37'-8'/2 166 38'-0 1287.47 6.3570 42'-2'/2 0.044651 1.885 T(37'-8'/2) 166 38'-0 187.27 6 (See 251'-4 120 97.495 Notes) Flow(q)from Route 7 155'-11 15.187 155 2'-11'/2 1474.75 6.3570 407'-3 0.057404 23.378 4E(17'-7),CV(47'-9'/z), PO(37'- 8'/2) 155 2' 11'/2 8 (See 5'-6'/2 120 136.060 Notes) 15'-3 0.000 17 2'-11'/2 1474.75 8.2490 20'-9'/2 0.016140 0.336 fE(15'-3), BOR 17 2'-11'/2 8 (See 3'-1 120 136.396 Notes) 66' 11'/2 -0.000 113 2'-11'h 1474.75 8.2490 70' 0.016140 1.130 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 V-8'/2 120 137.526 0.000 1 2'-11'/2 1474.75 6.3570 0.057404 1'-8'h 0.099 1 1474.75 Pump 137.625 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5'-4 120 52.316 Notes) 43'-5'/2 0.359 0.016140 GV(4'-8'/2),fT(38'-9) 526 2'-1/2 1474.75 8.2490 48'-9'/2 0.787 526 2'-1'/2 10 (See 5-2 120 53.462 Notes) 20'-1 2.247 115 -3'-0'/2 1474.75 10.3700 25-3%2 0.005296 0.134 E(20'-1) L{/©M.E.P.CAD A-AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 9 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 115 -3'0'/z 10 (See 176'-7 140 55.843 Notes) 149'-10'/z -1.319 150 0'-0 1474.75 10.4000 326'-5%2 0.003926 6.652 2E(35'-1),BFP(-5.370),T(79'- 8'/2) 150 0'-0 E12.4600 (See 119'-2'/2 140 61.176 Notes) 44'-3 151 0'-0 1474.75 163'-5 0.266 0.001628 S, E(44'-3) 250.00 61.442 Hose Allowance At Source 151 1724.75 Total(Pt) Route 1 10'-0 120 52.000 •••••Route 2••••• 408 39'-0 16.8 121.15 2 (See Sprinkler Notes) 411 39'-0 113.64 2.2030 0.087279 10'-0 0.873 411 39'-0 16.8 122.16 2 (See 66-5 120 52.873 Sprinkler, Notes) 2T-3'/z 0.434 178 38'-0 235.80 2.2030 93'-8 31.554 0.336804 2PO(13'-7'/z) 178 38'-0 258.49 4 10'-0 120 84.861 Flow(q)from Route 6 179 38'-0 494.29 4.3100 0.050422 10'-0 0.504 179 38'-0 237.02 4 10'-0 120 85.365 Flow(q)from Route 4 180 38'-0 731.32 4.3100 0.104074 10'-0 1.041 180 38'-0 4 10'-0 120 86.405 181 38'-0 668.93 4.3100 0.088247 10'-0 0.882 181 38'-0 4 10'-0 120 87.288 182 38'-0 610.21 4.3100 0.074454 10'-0 0.745 182 38'-0 4 10'-0 120 88.032 183 38'-0 554.44 4.3100 0.062357 10'-0 0.624 183 38'-0 4 10'-0 120 88.656 184 38'-0 500.89 4.3100 0.051674 10'-0 0.517 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 10 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 184 38'-0 4 10'-0 120 89.173 185 38'-0 448.82 4.3100 0.042178 10'-0 0.422 185 38'-0 4 10'-0 120 89.595 186 38'-0 397.53 4.3100 0.033696 10'-0 0.337 186 38'-0 4 10'-0 120 89.932 187 38'-0 346.34 4.3100 0.026111 10'-0 0.261 187 38'-0 4 10'-0 120 90.193 188 38'-0 294.60 4.3100 0.019357 10'-0 0.194 188 38'-0 2 (See 172'-8 120 90.386 Notes) 54'-6'/z 164 38'-0 52.85 2.2030 0.021174 3PO(13'-7'/z) r22T-3 1 4.811 95.198 Total(Pt) Route 2 409 39'-0 16.8 121.36 2 (See 10'-0 120 52.187 •••••Route 3••••• Notes) Sprinkler 406 39'-0 6.73 2.2030 0.000468 10'-0 0.005 406 39'-0 16.8 121.37 2 (See 10'-0 120 52.192 Sprinkler Notes) 403 39'-0 128.10 2.2030 0.108932 10'-0 1.089 403 39'-0 16.8 122.63 2 (See 76'-3 120 53.281 Sprinkler, Notes) 2T-3'/z 0.434 154 38'-0 250.73 2.2030 0.377322 2PO(13'-7'/z) 103-6'/2 39.070 92.784 Total(Pt) Route 3 409 39'-0 16.8 121.36 2 (See 10'-0 120 52.187 •••••Route 4••••• Notes) Sprinkler 412 39'-0 114.63 2.2030 0.088691 10'-0 0.887 412 39'-0 16.8 122.39 2 (See 66-5 120 53.074 Sprinkler, Notes) 27 3'/z 0.434 93-8 31.857 179 38'-0 237.02 2.2030 0.340040 2PO(13'-7'/z) ' 85.365 Total(Pt) Route 4 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 11 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) Foot) (psi) Friction(Pf) directly to(Pf)and shown as ( 10'-0 120 54.864 •••••Route s••••• 404 39'-0 16.8 124.44 2 (See Sprinkler Notes) 401 39'-0 116.15 2.2030 0.090876 10'-0 0.909 401 39'-0 16.8 125.46 2 (See 76-3 120 55.773 Sprinkler, Notes) 27'-3'/z 0.434 152 38'-0 241.61 2.2030 103'-6'/2 0.352328 36.482 2PO(13'-7'/z) 152 38'-0 6 10'-0 120 92.688 153 38'-0 241.61 6.3570 0.002021 10'-0 0.020 92.708 Total(Pt) Route 5 10'-0 120 54.864 •••••Route 6••••• 404 39'-0 16.8 124.44 2 (See Sprinkler Notes) 407 39'-0 8.29 2.2030 0.000688 10'-0 0.007 407 39'-0 16.8 124.45 2 (See 10'-0 120 54.871 Sprinkler Notes) 410 39'-0 132.74 2.2030 0.116333 10'-0 1.163 410 39'-0 16.8 125.76 2 (See 59'-6 120 56.035 Sprinkler Notes) 173 39'-0 258.49 2.2030 0.399216 59'-6 23.753 173 39'-0 2 (See 6'-11 120 79.788 Notes) 27'-3'/z 0.434 177 38'-0 141.68 2.2030 34'2 0.131248 4.487 2PO(13'-7'/z) 177 38'-0 116.81 4 10'-0 120 84.709 Flow(q)from Route 10 178 38'-0 258.49 4.3100 0.015198 10'-0 0.152 84.861 Total(Pt) Route 6 167 38'-0 124.53+62.74 4 (See 5'-6 120 97.213 .....Route 7 Notes) 26'-4 Flow(q)from Route 8 and 21 166 38'-0 187.27 4.2600 31'-10 0.282 0.008862 T(26'-4) 97.495 Total(Pt) Route 7 168 38'-0 62.21 +62.32 4 10'-0 120 97.171 .....Route 8 Flow(q)from Route 9 and 13 167 38'-0 124.53 4.2600 0.004166 10'-0 0.042 �{ ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 12 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 97.213 I Total(Pt) Route 8 169 38'-0 62.21 4 10'-0 120 97.160 •••••Route 9 Flow(q)from Route 14 168 38'-0 62.21 4.2600 0.001154 10'-0 0.012 97.171 Total(Pt) Route 9 173 39'-0 2 (See 9'-0 120 79.788 •••••Route 10••••• Notes) 24'-7,/z 172 39'-0 116.81 2.1570 33'-7'/z 0.101783 3.421 T(12'-3'/2) 172 39'-0 2 (See 6'-11 120 83.209 Notes) 2T-3'/z 0.434 176 38'-0 64.09 2.2030 34'2 0.030254 1.034 T(13'-7'/z), PO(13'-7'/z) 176 38'-0 52.72 4 91-0 120 84.677 Flow(q)from Route 11 177 38'-0 116.81 4.3100 0.003496 9'-0 0.031 84.709 Total(Pt) Route 10 8'-0 120 83.209 •••••Route 11 172 39'-0 2 (See T(12'-3'/2) Notes) 24'-7,/z 171 39'-0 52.72 2.1570 -7'/z 0.023360 0.762 T(12'-3'/z) 32' 171 39'-0 2 (See 6'-11 120 83.971 Notes) 2T-3'/z 0.434 175 38'-0 30.77 2.2030 0.007782 0.266 T(13'-7'/z), PO(13'-7'/z) 34'-2 175 38'-0 21.96 4 8'-0 120 84.671 Flow(q)from Route 12 176 38'-0 52.72 4.3100 0.000802 8'-0 0.006 84.677 Total(Pt) Route 11 171 39'-0 2 (See 8'-0 120 83.971 •••••Route 12••••• Notes) 18'-5,/2 170 39'-0 21.96 2.1570 26'-5'/s 0.004620 0.122 E(6'-2) 170 39'-0 2 (See 6'-11 120 84.093 Notes) 27'-3'/2 0.434 0.004169 T(13'-7'/z), PO(13'-7%) 174 38'-0 21.96 2.2030 rM'-2 0.143 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 13 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 174 38'-0 4 8'-0 120 84.669 175 38'-0 21.96 4.3100 0.000159 8'-0 0.001 84.671 Total(Pt) Route 12 191 38'-0 124.53 2 (See 172'-8 120 90.644 .....Route 13 PO(13'-7'/2), Flow(q)from Notes 54'-6'/z Route 23 227'-3 6.528 168 38'-0 62.32 2.2030 0.028727 3PO(13'-7'/z) 97.171 Total(Pt) Route 13 191 38'-0 124.53 4 10'-0 120 90.644 .....Route 14 Flow(q)from Route 23 192 38'-0 62.21 4.3100 0.001090 10'-0 0.011 192 38'-0 2 (See 172'-8 120 90.654 Notes) L227 6.505 169 38'-0 62.21 2.2030 0.028628 3PO(13'-7'/z) 97.160 Total(Pt) Route 14 172'-8 120 88.032 .....Route 15 182 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 158 38'-0 55.77 2.2030 227'-3 5.315 0.023388 3PO(13'-7'/z) 93.347 Total(Pt) Route 15 172'-8 120 90.193 •••••Route 16••••• 187 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/2 163 38'-0 51.73 2.2030 227'-3 4.625 0.020353 3PO(13'-7'/z) 94.818 Total(Pt) Route 16 184 38'-0 2 (See 172'-8 120 89.173 •••••Route 17••••• PO(13'-7'/z) Notes) 54'-6'/z 160 38'-0 52.07 2.2030 227'-3 4.681 0.020598 3PO(13'-7'/z) 93.853 Total(Pt) Route 17 186 38' 0 2 (See 172'-8 120 89.932 .....Route 18 PO(13'-7'/z) Notes) 54'-6'/z 162 38'-0 51.19 2.2030 227'-3 4.536 0.019963 3PO(13'-7'/z) 94.468 Total(Pt) Route 18 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 14 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 172'-8 120 89.595 •••••Route 19••••• 185 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/z 161 38'-0 51.29 2.2030 227'-3 4.552 0.020033 3PO(13'-7'/z) 94.147 Total(Pt) Route 19 189 38'-0 241.75 2 (See 172'-8 120 90.521 .....Route 20 PO(13'-7'/2), Flow(q)from Notes 54'-6'/z Route 22 227'-3 5.089 165 38'-0 54.48 2.2030 0.022397 3PO(13'-7'/z) 95.610 Total(Pt) Route 20 189 38'-0 241.75 4 10'-0 120 90.521 .....Route 21 Flow(q)from Route 22 190 38'-0 187.27 4.3100 0.008372 10'-0 0.084 190 38'-0 2 (See 172'-8 120 90.604 Notes) L227 6.609 167 38'-0 62.74 2.2030 0.029084 3PO(13'-7'/z) 97.213 Total(Pt) Route 21 188 38'-0 52.85 4 10'-0 120 90.386 .....Route 22 Flow(q)from Route 2 189 38'-0 241.75 4.3100 0.013427 10'-0 0.134 90.521 Total(Pt) Route 22 190 38'-0 62.74 4 10'-0 120 90.604 .....Route 23 Flow(q)from Route 21 191 38'-0 124.53 4.3100 0.003936 10'-0 0.039 90.644 Total(Pt) Route 23 183 38'-0 2 (See 172'-8 120 88.656 .....Route 24 PO(13'-7'/z) Notes) 54'-6'/z 159 38'-0 53.56 2.2030 227'-3 4.931 0.021700 3PO(13'-7'/z) 93.587 Total(Pt) Route 24 180 38' 0 2 (See 172'-8 120 86.405 .....Route 25 PO(13'-7'/2) Notes) 54'-6'/z 156 38'-0 62.39 2.2030 227'-3 6.540 0.028782 3PO(13'-7'/z) 92.946 Total(Pt) Route 25 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 15 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 172'-8 120 87.288 •••••Route 26 181 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/z 157 38'-0 58.71 2.2030 227'-3 5.845 0.025724 3PO(13'-7'/z) 93.133 Total(Pt) Route 26 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 2 3/31/2025 9:57:59AM Page 16 Job Name: North Sound Logistics Remote Area Number: 2 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 2 3/31/2025 9:57:59AM Page 17 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 3 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 95ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1711.22 @ 62.938 (Safety Margin = 13.471) from Pump at Node: 1: 1461.22 @ 139.392 (Safety Margin = 13.471) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: 62.600 Right: 62.660 ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY ' FIRE PROTECTION SPRINKLER SYSTEMS , Brandon James Stewart , ' 3259-0615-C-H Level N , AFP Systems,Inc. o AFPSYI*091 BZ ,�o , 94M,44,%41VA4 Expires Signature 12/31/25 , �©M.E.P.CAD �AutoSPRINK 2024 v19.0.46.0 3 3/31/2025 9:57:26AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(3) Remote Area Number:3 100 3A 82 36 3 64 ____al 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:62.938 @ 1461.22 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):62.938 @ 1711.22 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.409 @ 1711.22 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 "n ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:57:28AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(3) Remote Area Number:3 200 7A 172 7B 144 • 1B 116 7 5A 88 5B 2A SC N Q 60 2B 5 2C 02D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Data nt Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:139.392 @ 1461.22 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.390 @ 1461.22 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.390 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.390 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.473 @ 1461.22 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.863 @ 1461.22 M[J©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:57:28AM Page 3 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.409 1711.22 62.938 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.863 1461.22 139.392 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 101 39'-0 Sprinkler 52.996 122.30 102 39'-0 Sprinkler 53.015 122.32 103 39'-0 Sprinkler 53.109 122.43 104 39'-0 Sprinkler 52.000 121.15 105 39'-0 Sprinkler 52.021 121.17 106 39'-0 Sprinkler 52.113 121.28 107 39'-0 Sprinkler 52.000 121.15 108 39'-0 Sprinkler 52.021 121.17 109 39'-0 Sprinkler 52.113 121.28 110 39'-0 Sprinkler 52.969 122.27 111 39'-0 Sprinkler 52.992 122.30 112 39'-0 Sprinkler 53.086 122.40 151 0'-0 Supply 62.938 1461.22 1 2'-11'/z P2 139.392 P2(-85.473) 17 2'-11'/z Gauge 138.184 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:31AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 61 38'-0 87.446 62 38'-0 87.465 63 38'-0 87.405 64 38'-0 87.473 65 38'-0 87.355 66 38'-0 87.476 67 38'-0 87.283 68 38'-0 87.172 69 38'-0 87.173 70 38'-0 87.323 71 38'-0 87.842 72 38'-0 88.297 73 38'-0 88.694 74 38'-0 89.040 75 38'-0 89.336 76 38'-0 89.587 77 38'-0 89.795 78 38'-0 89.962 79 38'-0 90.091 80 38'-0 90.183 81 38'-0 90.243 82 38'-0 90.276 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:57:31AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 83 38'-0 90.285 84 38'-0 88.680 85 38'-0 88.661 86 38'-0 88.720 87 38'-0 88.652 88 38'-0 88.770 89 38'-0 88.650 90 38'-0 88.842 91 36'-0 90.165 92 38'-0 89.518 93 38'-0 89.588 94 38'-0 89.739 95 38'-0 89.998 96 38'-0 90.275 97 38'-0 90.568 98 38'-0 90.879 99 38'-0 91.207 100 38'-0 91.554 113 2'-11'/z 139.295 114 2'-11'/z P1 53.919 115 -3'-0'/2 57.431 150 0'-0 62.676 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:57:31AM Paqe 6 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 442 35-4 107.089 526 2'-1'/2 55.052 625 38'-0 95.657 908 38'-0 95.659 995 38'-0 95.680 1085 38'-0 93.600 1213 38'-0 93.143 1339 38'-0 92.712 1466 38'-0 92.304 1596 38'-0 91.919 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:57:31AM Paqe 7 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 10'-0 120 52.000 .....Route 1 107 39'-0 16.8 121.15 2 (See Sprinkler Notes) 110 39'-0 120.25 2.2030 0.096898 10'-0 0.969 110 39'-0 16.8 122.27 2 (See 74'-6'/z 120 52.969 Sprinkler, Notes) 27'-3'/z 0.434 92 38'-0 242.52 2.2030 101'-9'/2 0.354771 36.115 2PO(13'-7'/z) 92 38'-0 231.15 6 10'-0 120 89.518 Flow(q)from Route 7 93 38'-0 473.67 6.3570 0.007022 10'-0 0.070 93 38'-0 242.69 6 10'-0 120 89.588 Flow(q)from Route 3 94 38'-0 716.36 6.3570 0.015094 10'-0 0.151 94 38'-0 242.90 6 10'-0 120 89.739 Flow(q)from Route 5 95 38'-0 959.25 6.3570 0.025905 10'-0 0.259 95 38'-0 34.47 6 10'-0 120 89.998 Flow(q)from Route 2 96 38'-0 993.72 6.3570 0.027654 10'-0 0.277 96 38'-0 32.90 6 10'-0 120 90.275 Flow(q)from Route 14 97 38'-0 1026.62 6.3570 0.029371 10'-0 0.294 97 38'-0 31.96 6 10'-0 120 90.568 Flow(q)from Route 15 98 38'-0 1058.58 6.3570 0.031085 10'-0 0.311 98 38'-0 31.64 6 10'-0 120 90.879 Flow(q)from Route 16 99 38'-0 1090.22 6.3570 0.032826 10'-0 0.328 99 38'-0 31.93 6 10'-0 120 91.207 Flow(q)from Route 17 100 38'-0 1122.15 6.3570 0.034627 10'-0 0.346 100 38'-0 32.80 6 10'-0 120 91.554 Flow(q)from Route 18 1596 38'-0 1154.95 6.3570 0.036522 10'-0 0.365 LM ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 8 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 1596 38'-0 34.19 6 10'-0 120 91.919 Flow(q)from Route 19 1466 38'-0 1189.15 6.3570 0.038548 10'-0 0.385 1466 38'-0 36.05 6 10'-0 120 92.304 Flow(q)from Route 20 1339 38'-0 1225.20 6.3570 0.040738 10'-0 0.407 1339 38'-0 38.31 6 10'-0 120 92.712 Flow(q)from Route 21 1213 38'-0 1263.51 6.3570 0.043126 10'-0 0.431 1213 38'-0 40.91 6 10'-0 120 93.143 Flow(q)from Route 22 1085 38'-0 1304.43 6.3570 0.045745 10'-0 0.457 1085 38'-0 43.80 6 (See 5'-0'/2 120 93.600 Flow(q)from Route 23 Notes) 37'-8,/2 995 38'-0 1348.23 6.3570 42 9 0.048627 2.079 T(37'-8'/2) 995 38'-0 112.99 6 (See 128'-10'/2 120 95.680 Flow(q)from Route 24 Notes) 52'-9'/2 1.156 442 35-4 1461.22 6.3570 0.056434 10.253 3E(17'-7) 181'-8'/2 442 35'4 g (See 787'-10'/2 120 107.089 Notes) 287'-6 14.031 17 2'-11'/2 1461.22 8.2490 0.015867 CV(71'-5),3PO(41'-1'/2),3E(21 1075'-4/2 17.063 '-1'/2), BV(14'-1),fE(15-3), BOR 17 2'-11'/2 8 (See 3'-1 120 138.184 Notes) 66-11'/2 -0.000 113 2'-11'/2 1461.22 8.2490 70'-0'/z 0.015867 1.111 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 V-8'/2 120 139.295 0.000 1 2'-11'/2 1461.22 6.3570 0.056434 1'-8'/z 0.097 1 1461.22 Pump 139.392 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5'-4 120 53.919 Notes) 43'-5'/2 0.359 526 2'-1'/2 1461.22 8.2490 48'-9%2 0.015867 0.774 GV(4'-8'/2),fT(38'-9) LM ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 9 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 526 2'-1'/2 10 (See 5'-2 120 55.052 Notes) 20'-1 2.247 115 -3'-0'/z 1461.22 10.3700 25'-3'/z 0.005206 0.132 E(20'-1) 115 -3'-0'/z 10 (See 176'-7 140 57.431 Notes) 149'-10'/z -1.319 0.003860 2E(35'-1),BFP(-5.305),T(79'- 150 0'-0 1461.22 10.4000 326' 6.565 8'/2) 150 0'0 12 (See 119'-2'/2 140 62.676 Notes) 44'-3 151 0'-0 1461.22 12.4600 0.001601 S, E(44'-3) 163-5 0.262 250.00 62.938 Hose Allowance At Source 151 1711.22 Total(Pt) Route 1 8'-10'/z 120 52.000 •••••Route 2••••• 107 39'-0 16.8 121.15 2 (See Sprinkler Notes) 104 39'-0 0.90 2.2030 0.000011 0.000 104 39'-0 16.8 121.15 2 (See 10'-0 120 52.000 Sprinkler Notes) 101 39'-0 122.05 2,2030 0.099595 10'-0 0.996 101 39'-0 16.8 122.30 2 (See 66-6 120 52.996 Sprinkler, Notes) 2T-3'/z 0.434 68 38'-0 244.35 2.2030 93'-9'/z 0.359737 33.742 2PO(13'-7'/z) 68 38'-0 4 10'-0 120 87.172 69 38'-0 13.20 4.3100 0.000062 10'-0 0.001 69 38'-0 244.27 4 10'-0 120 87.173 Flow(q)from Route 4 70 38'-0 257.47 4.3100 0.015087 10'-0 0.151 70 38'-0 244.50 4 10'-0 120 87.323 Flow(q)from Route 6 71 38'-0 501.97 4.3100 0.051880 10'-0 0.519 71 38'-0 2 (See 169'-11 120 87.842 Notes) 54 6'/z 224'-5'/z 95 38'-0 34.47 2.2030 0.009604 2.156 3PO(13'-7'/z) �{ ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 10 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 89.998 I Total(Pt) Route 2 10'-0 120 52.021 •••••Route 3••••• 108 39'-0 16.8 121.17 2 (See Sprinkler Notes) 111 39'-0 120.39 2.2030 0.097114 10'-0 0.971 111 39'-0 16.8 122.30 2 (See 74'-6'/z 120 52.992 Sprinkler, Notes) 27-3'/z 0.434 93 38'-0 242.69 2.2030 0.355234 2PO(13'-7'/z) 101'-9'/z 36.163 89.588 Total(Pt) Route 3 8'-10'/z 120 52.021 •••••Route 4••••• 108 39'-0 16.8 121.17 2 (See Sprinkler Notes) 105 39'-0 0.78 2.2030 0.000009 8'-10'/z 0.000 105 39'-0 16.8 121.17 2 (See 10'-0 120 52.021 Sprinkler Notes) 102 39'-0 121.95 2.2030 0.099450 10'-0 0.995 102 39'0 16.8 122.32 2 (See 66-6 120 53.015 Sprinkler, Notes) 27'-3'/z 0.434 69 38'-0 244.27 2.2030 93-9'/z 0.359536 33.724 2PO(13'-7'/z) 87.173 Total(Pt) Route 4 10'-0 120 52.113 •••••Route s••••• 109 39'-0 16.8 121.28 2 (See Sprinkler Notes) 112 39'-0 120.49 2.2030 0.097263 10'-0 0.973 112 39'-0 16.8 122.40 2 (See 74'-6'/z 120 53.086 Sprinkler, Notes) 27'-3'/z 0.434 94 38'-0 242.90 2.2030 0.355797 2PO(13'-7'/z) 101'-9'/z 36.220 89.739 Total(Pt) Route 5 109 39'-0 16.8 121.28 2 (See 8'-10'/z 120 52.113 •••••Route 6••••• Notes) Sprinkler 106 39'-0 0.79 2.2030 0.000009 8'-10'/z 0.000 106 39'-0 16.8 121.28 2 (See 10'-0 120 52.113 Sprinkler Notes) 103 39'-0 122.06 2.2030 0.099623 10'-0 0.996 L{/©M.E.P.CAD A.]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 11 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 103 39'0 16.8 122.43 2 (See 66'-6 120 53.109 Sprinkler, Notes) 27'-3'/z 0.434 70 38'-0 244.50 2.2030 0.360144 2PO(13'-7'/z) 93'-9'/z 33.781 87.323 Total(Pt) Route 6 68 38'-0 13.20 4 9'-0 120 87.172 .....Route 7 Flow(q)from Route 2 67 38'-0 231.15 4.3100 0.012358 9'-0 0.111 67 38'-0 2 (See 91'-2'/z 120 87.283 Notes) 54'-6'/z 90 38'-0 36.54 2.2030 145-9 0.010696 1.559 3PO(13'-7'/z) 90 38'-0 194.61 4 (See 8'-11'/z 120 88.842 Flow(q)from Route 8 Notes) 27'-10'/2 0.867 91 36'-0 231.15 4.3100 36'-10 0.455 0.012358 2E(13'-11) 91 36'-0 6 (See 83'-1 120 90.165 Notes) 35-2'/z -0.867 92 38'-0 231.15 6.3570 118'-3'h 0.220 0.001862 2E(17'-7) 89.518 Total(Pt) Route 7 67 38'-0 36.54 4 8'-0 120 87.283 .....Route 8 Flow(q)from Route 7 65 38'-0 194.61 4.3100 0.008989 8'-0 0.072 65 38'-0 2 (See 91'-2'/z 120 87.355 Notes) 54'-6'/z 88 38'-0 34.67 2.2030 145-9 0.009709 1.415 3PO(13'-7'/z) 88 38'-0 159.94 4 8'-0 120 88.770 Flow(q)from Route 9 90 38'-0 194.61 4.3100 0.008989 8'0 0.072 88.842 Total(Pt) Route 8 65 38'-0 34.67 4 8'-0 120 87.355 .....Route 9 Flow(q)from Route 8 63 38'-0 159.94 4.3100 0.006253 8'-0 0.050 63 38'-0 2 (See 91'-2'/z 120 87.405 Notes) PO(13'-7'/z) L5461/2d86 38'-0 33.33 2.2030 0.009023 3PO(13'-7'/z) 1.315 �{ ©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 12 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to(Pf)and shown as 86 38'-0 126.61 4 8'-0 120 88.720 Flow(q)from Route 10 88 38'-0 159.94 4.3100 0.006253 8'-0 0.050 88.770 Total(Pt) Route 9 63 38'-0 33.33 4 10'-0 120 87.405 .....Route 10 Flow(q)from Route 9 61 38'-0 126.61 4.3100 0.004058 10'-0 0.041 61 38'-0 2 (See 91'-2'/z 120 87.446 Notes) 54'-6'/z 84 38'-0 32.20 2.2030 145-9 0.008466 1.234 3PO(13'-7'/z) 84 38'-0 94.41 4 10'-0 120 88.680 Flow(q)from Route 11 86 38'-0 126.61 4.3100 0.004058 10'-0 0.041 88.720 Total(Pt) Route 10 61 38'-0 32.20 4 8'-0 120 87.446 .....Route 11 Flow(q)from Route 10 62 38'-0 94.41 4.3100 0.002358 8'-0 0.019 62 38'-0 2 (See 91'-2'/z 120 87.465 Notes) 54'-6'/z 85 38'-0 31.66 2.2030 145-9 0.008207 1.196 3PO(13'-7'/z) 85 38'-0 62.75 4 8'-0 120 88.661 Flow(q)from Route 12 84 38'-0 94.41 4.3100 0.002358 8'0 0.019 88.680 Total(Pt) Route 11 62 38'-0 31.66 4 8'-0 120 87.465 .....Route 12 Flow(q)from Route 11 64 38'-0 62.75 4.3100 0.001107 8'-0 0.009 64 38'-0 2 (See 91'-2'/z 120 87.473 Notes) 54-6 PO(13'-7'/z) ' '/z 87 38'-0 31.41 2.2030 145'-9 1.179 0.008086 3PO(13'-7'/z) 87 38'-0 31.34 4 8'-0 120 88.652 Flow(q)from Route 13 85 38'-0 62.75 4.3100 8 0.001107 '-0 0.009 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 13 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 88.661 I Total(Pt) Route 12 64 38'-0 31.41 4 8'-0 120 87.473 •••••Route 13 Flow(q)from Route 12 66 38'-0 31.34 4.3100 0.000307 8'-0 0.002 66 38'-0 2 (See 91'-2'/z 120 87.476 Notes) 54'-6'/z 89 38'-0 31.34 2.2030 145-9 0.008052 1.174 3PO(13'-7'/z) 89 38'-0 4 8'-0 120 88.650 87 38'-0 31.34 4.3100 0.000307 r7FO771 0.002 88.652 Total(Pt) Route 13 71 38'-0 34.47 4 10'-0 120 87.842 .....Route 14 Flow(q)from Route 2 72 38'-0 467.50 4.3100 0.045482 10'-0 0.455 72 38'-0 2 (See 169'-11 120 88.297 Notes) 54 6 2 96 38'-0 32.90 2.2030 0.008810 3PO(13'-7'/z) 224'S'/z 1.977 90.275 Total(Pt) Route 14 72 38'-0 32.90 4 10'-0 120 88.297 .....Route 15 Flow(q)from Route 14 73 38'-0 434.60 4.3100 0.039738 10'-0 0.397 73 38'-0 2 (See 169'-11 120 88.694 Notes) PO(13'-7'/z) 54'-6'/z 97 38'-0 31.96 2.2030 0.008348 3PO(13'-7'/z) L2 222 4'-5'/2 1.874 90.568 Total(Pt) Route 15 73 38'-0 31.96 4 10'-0 120 88.694 .....Route 16 Flow(q)from Route 15 74 38'-0 402.64 4.3100 0.034502 10'-0 0.345 74 38'-0 2 (See 169'-11 120 89.040 Notes) 54'-6'/2 98 38'-0 31.64 2.2030 0.008196 3PO(13'-7'/z) 224'-5'/2 1.840 90.879 Total(Pt) Route 16 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 14 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 74 38'-0 31.64 4 10'-0 120 89.040 .....Route 17 Flow(q)from Route 16 75 38'-0 371.00 4.3100 0.029655 10'-0 0.297 75 38'-0 2 (See 169'-11 120 89.336 Notes) 54'-6 2 99 38'-0 31.93 2.2030 0.008337 3PO(13'-7'/z) 224'-5'/2 1.871 91.207 Total(Pt) Route 17 75 38'-0 31.93 4 10'-0 120 89.336 .....Route 18 Flow(q)from Route 17 76 38'-0 339.07 4.3100 0.025106 10'-0 0.251 76 38'-0 2 (See 169'-11 120 89.587 Notes) 54'-6'/z 100 38'-0 32.80 2.2030 0.008762 3PO(13'-7'/z) 224'-5/2 1.967 91.554 Total(Pt) Route 18 76 38'-0 32.80 4 10'-0 120 89.587 .....Route 19 Flow(q)from Route 18 77 38'-0 306.26 4.3100 0.020798 10'-0 0.208 77 38'-0 2 (See 169'-11 120 89.795 Notes) 54 6 2 1596 38'-0 34.19 2.2030 0.009462 3PO(13'-7'/z) 224'S'/z 2.124 91.919 Total(Pt) Route 19 77 38'-0 34.19 4 10'-0 120 89.795 .....Route 20 Flow(q)from Route 19 78 38'-0 272.07 4.3100 0.016707 10'-0 0.167 78 38'-0 2 (See 169'-11 120 89.962 Notes) PO(13'-7'/z) 54'-6'/z 1466 38'-0 36.05 2.2030 0.010435 3PO(13'-7'/z) L2 222 4'-5'/2 2.342 92.304 Total(Pt) Route 20 78 38'-0 36.05 4 10'-0 120 89.962 .....Route 21 Flow(q)from Route 20 79 38'-0 236.02 4.3100 0.012844 10'-0 0.128 �{ ©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 15 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 79 38'0 2 (See 169'-11 120 90.091 PO(13'-7'/2) Notes) 54'-6'/z 1339 38'-0 38.31 2.2030 224'-5'/2 0.011678 2.621 3PO(13'-7'/z) 92.712 Total(Pt) Route 21 79 38'-0 38.31 4 10'-0 120 90.091 .....Route 22 Flow(q)from Route 21 80 38'-0 197.70 4.3100 0.009255 10'-0 0.093 80 38'-0 2 (See 169'-11 120 90.183 Notes) 54'-6'/z 1213 38'-0 40.91 2.2030 224'-5'/2 0.013187 2.960 3PO(13'-7'/z) 93.143 Total(Pt) Route 22 80 38'-0 40.91 4 10'-0 120 90.183 .....Route 23 Flow(q)from Route 22 81 38'-0 156.79 4.3100 0.006027 10'-0 0.060 81 38'-0 2 (See 169'-11 120 90.243 PO(13'-7'/z) Notes) 54'-6'/z 1085 38'-0 43.80 2.2030 224'-5'/z 0.014957 3.357 3PO(13'-7'/z) 93.600 Total(Pt) Route 23 81 38'-0 43.80 4 10'-0 120 90.243 .....Route 24 Flow(q)from Route 23 82 38'-0 112.99 4.3100 0.003288 10'-0 0.033 82 38' 0 2 (See 169'-11 120 90.276 Notes) 54-6 PO(13'-7'/2) ' '/z 908 38'-0 56.53 2.2030 224'-5'/2 0.023980 5.382 3PO(13'-7'/z) 908 38'-0 56.47 6 (See 4'-11'/z 120 95.659 Flow(q)from Route 25 Notes) 37'-8,/z 995 38'-0 112.99 6.3570 42' 8 0.000495 0.021 T(37'-8'/z) 95.680 Total(Pt) Route 24 82 38'-0 56.53 4 10'-0 120 90.276 .....Route 25 Flow(q)from Route 24 83 38'-0 56.47 4.3100 0.000911 10'-0 0.009 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 16 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 83 38'0 2 (See 169'-11 120 90.285 PO(13'-7'/2) Notes) 54'-6'/z 625 38'-0 56.47 2.2030 224'-5'/2 0.023933 5.372 3PO(13'-7'/z) 625 38'-0 6 10'-0 120 95.657 908 38'-0 56.47 6.3570 r- 0.000137 10'-0 0.001 95.659 Total(Pt) Route 25 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 3 3/31/2025 9:57:34AM Page 17 Job Name: North Sound Logistics Remote Area Number: 3 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 3 3/31/2025 9:57:33AM Page 18 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 4 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 95ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1711.95 @ 63.578 (Safety Margin = 12.821) from Pump at Node: 1: 1461.95 @ 140.017 (Safety Margin = 12.821) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: 62.948 Right: 63.766 ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Brandon James Stewart <<^ ' 3259-0615-C-H Leve13 AFP Systems,Inc. o AFPSYI*091BZ �o , Ex ,res � Signature 12/31/25 , ---------------------------' �©M.E.P.CAD �AutoSPRINK 2024 v19.0.46.0 4 3/31/2025 9:56:56AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(4) Remote Area Number:4 100 3A 82 36 3 64 ---- 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:63.578 @ 1461.95 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):63.578 @ 1711.95 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.398 @ 1711.95 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 An ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:56:58AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(4) Remote Area Number:4 200 7A 172 7B 144 1 B 116 7 5A 88 5B 2A SC N Q 60 2B 5 2C 2D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Data Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:140.017 @ 1461.95 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.374 @ 1461.95 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.374 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.374 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.464 @ 1461.95 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.838 @ 1461.95 LM ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:56:58AM Page 3 Job Name: North Sound Logistics Remote Area Number: 4 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.398 1711.95 63.578 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.838 1461.95 140.017 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 151 0'-0 Supply 63.578 1461.95 201 39'-0 Sprinkler 53.153 122.48 202 39'-0 Sprinkler 53.199 122.53 203 39'-0 Sprinkler 53.362 122.72 204 39'-0 Sprinkler 52.010 121.16 205 39'-0 Sprinkler 52.058 121.21 206 39'-0 Sprinkler 52.229 121.41 207 39'-0 Sprinkler 52.000 121.15 208 39'-0 Sprinkler 52.048 121.20 209 39'-0 Sprinkler 52.220 121.40 210 39'-0 Sprinkler 52.833 122.11 211 39'-0 Sprinkler 52.885 122.17 212 39'-0 Sprinkler 53.070 122.39 1 2'-11'/z P2 140.017 P2(-85.464) 17 2'-11'/z Gauge 138.808 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:02AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 4 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 113 2'-11'/2 139.920 114 2'-11'/2 P1 54.553 115 -3'-0'/2 58.066 116 38'-0 90.524 117 38'-0 90.546 118 38'-0 90.626 119 38'-0 90.795 120 38'-0 90.989 121 38'-0 91.209 122 38'-0 91.454 123 38'-0 91.725 124 38'-0 92.022 125 38'-0 92.345 126 38'-0 92.697 127 38'-0 93.078 128 38'-0 93.491 129 38'-0 93.937 130 38'-0 94.419 131 38'-0 94.941 132 3'-0 123.935 133 38'-0 83.466 134 38'-0 83.591 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:02AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 4 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 135 38'-0 84.044 137 38'-0 85.005 138 38'-0 85.820 139 38'-0 86.507 140 38'-0 87.083 141 38'-0 87.560 142 38'-0 87.949 143 38'-0 88.259 144 38'-0 88.498 145 38'-0 88.674 146 38'-0 88.795 147 38'-0 88.869 148 38'-0 88.906 149 38'-0 88.916 150 0'-0 63.316 526 2'-1'/z 55.687 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:57:02AM Paqe 6 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 10'-0 120 52.000 .....Route 1 207 39'-0 16.8 121.15 2 (See Sprinkler Notes) 204 39'-0 10.32 2.2030 0.001031 10'-0 0.010 204 39'-0 16.8 121.16 2 (See 10'-0 120 52.010 Sprinkler Notes) 201 39'-0 131.47 2.2030 0.114295 10'-0 1.143 201 39'-0 16.8 122.48 2 (See 68'-4 120 53.153 Sprinkler, Notes) 2T-3'/z 0.434 116 38'-0 253.96 95'-7'/z 2.2030 0.386347 36.937 2PO(13'-7'/z) 116 38'-0 6 10'-0 120 90.524 117 38'-0 253.96 6.3570 0.002216 10'-0 0.022 117 38'-0 253.87 6 10'-0 120 90.546 Flow(q)from Route 3 118 38'-0 507.83 6.3570 0.007987 10'-0 0.080 118 38'-0 253.56 6 10'-0 120 90.626 Flow(q)from Route 5 119 38'-0 761.39 6.3570 0.016896 10'-0 0.169 119 38'-0 59.84 6 10'-0 120 90.795 Flow(q)from Route 2 120 38'-0 821.23 6.3570 0.019434 10'-0 0.194 120 38'-0 56.28 6 10'-0 120 90.989 Flow(q)from Route 21 121 38'-0 877.51 6.3570 0.021970 10'-0 0.220 121 38'-0 53.47 6 10'-0 120 91.209 Flow(q)from Route 22 122 38'-0 930.98 6.3570 0.024511 10'-0 0.245 122 38'-0 51.40 6 10'-0 120 91.454 Flow(q)from Route 18 123 38'-0 982.38 6.3570 0.027073 10'-0 0.271 123 38'-0 50.08 6 10'-0 120 91.725 Flow(q)from Route 19 124 38'-0 1032.46 6.3570 0.029681 10'-0 0.297 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 7 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 124 38'-0 49.48 6 10'-0 120 92.022 Flow(q)from Route 16 125 38'-0 1081.94 6.3570 0.032366 10'-0 0.324 125 38'-0 49.57 6 10'-0 120 92.345 Flow(q)from Route 7 126 38'-0 1131.51 6.3570 0.035163 10'-0 0.352 126 38'-0 50.30 6 10'-0 120 92.697 Flow(q)from Route 8 127 38'-0 1181.81 6.3570 0.038109 10'-0 0.381 127 38'-0 51.61 6 10'-0 120 93.078 Flow(q)from Route 12 128 38'-0 1233.42 6.3570 0.041245 10'-0 0.412 128 38'-0 53.43 6 10'-0 120 93.491 Flow(q)from Route 13 129 38'-0 1286.85 6.3570 0.044611 10'-0 0.446 129 38'-0 55.68 6 10'-0 120 93.937 Flow(q)from Route 9 130 38'-0 1342.53 6.3570 0.048248 10'-0 0.482 130 38'-0 58.28 6 10'-0 120 94.419 Flow(q)from Route 10 131 38'-0 1400.81 6.3570 0.052193 10'-0 0.522 131 38'-0 61.14 6 (See 106'-4'/2 120 94.941 Flow(q)from Route 11 Notes) 138'-3'/2 15.173 132 3'-0 1461.95 6.3570 244'-8 0.056486 13.820 3E(17'-7), CV(47'-9'/2), PO(37'- 8'/2) 132 3'-0 8 (See 760'-7'/2 120 123.935 Notes) 175'-0 0.014 17 2'-11'/2 1461.95 8.2490 0.015882 2PO(41'-1'h),3E(21'-1'/2),BV( 935'-7/z 14.860 14'-1),fE(15'-3), BOR 17 2'-11'/2 8 (See 3' 1 120 138.808 Notes) 66-11'/2 -0.000 113 2'-11'/2 1461.95 8.2490 70'-0'/2 0.015882 1.112 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 1'-8'/2 120 139.920 0.000 1 2'-11'/2 1461.95 6.3570 0.056486 1'-8/2 0.097 LM ©M.E.P.CAD 411 AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 8 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to(Pf)and shown as 1 1461.95 Pump 140.017 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5'4 120 54.553 Notes) 43'-5'/2 0.359 0.015882 GV(4'-8'/2),fT(38'-9) 526 2'-1/2 1461.95 8.2490 48'-9'/2 0.775 526 2'-1'/2 10 (See 5-2 120 55.687 Notes) 20'-1 2.247 115 -3'-0'/2 1461.95 10.3700 0.005211 0.132 E(20'-1) 115 -3'-0'/2 10 (See 176'-7 140 58.066 Notes) 149'-10'/2 -1.319 150 0'-0 1461.95 10.4000 0.003863 2E(35'-1),BFP(-5.308),T(79'- 326'-5/2 6.569 8,/2) 150 0'-0 12 (See 119'-2'/2 140 63.316 Notes) 44'-3 151 0'-0 1461.95 12.4600 0.001602 S, E(44'-3) 163'-5 0.262 250.00 63.578 Hose Allowance At Source 151 1711.95 Total(Pt) Route 1 10'-0 120 52.000 .....Route 2 207 39'-0 16.8 121.15 2 (See Sprinkler Notes) 210 39'-0 110.83 2.2030 0.083329 10'-0 0.833 210 39'0 16.8 122.11 2 (See 64'-5 120 52.833 Sprinkler, Notes) 27'-3'/2 0.434 133 38'-0 232.94 2.2030 0.329298 30.199 2PO(13'-7'/2) 133 38'-0 4 10'-0 120 83.466 134 38'-0 232.94 4.3100 0.012536 10'-0 0.125 134 38'-0 233.25 4 10'-0 120 83.591 Flow(q)from Route 4 135 38'-0 466.20 4.3100 0.045248 10'-0 0.452 135 38'-0 234.36 4 10'-0 120 84.044 Flow(q)from Route 6 137 38'-0 700.56 4.3100 0.096122 10'-0 0.961 LM ©M.E.P.CAD A,]AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 9 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 137 38'0 2 (See 162'-9 120 85.005 PO(13'-7'/2) Notes) 54'-6'/z 119 38'-0 59.84 2.2030 217'-4 5.790 0.026644 3PO(13'-7'/z) 90.795 Total(Pt) Route 2 208 39'-0 16.8 121.20 2 (See 10'-0 120 52.048 •••••Route 3••••• Notes) Sprinkler 205 39'-0 10.12 2.2030 0.000995 10'-0 0.010 205 39'-0 16.8 121.21 2 (See 10'-0 120 52.058 Sprinkler Notes) 202 39'-0 131.34 2.2030 0.114073 10'-0 1.141 202 39'-0 16.8 122.53 2 (See 68'-4 120 53.199 Sprinkler, Notes) 27-3'/z 0.434 117 38'-0 253.87 2.2030 95-7'/z 0.386105 36.914 2PO(13'-7'/z) 90.546 Total(Pt) Route 3 10'-0 120 52.048 •••••Route 4••••• 208 39'-0 16.8 121.20 2 (See Sprinkler Notes) 211 39'-0 111.08 2.2030 0.083676 10'-0 0.837 211 39'-0 16.8 122.17 2 (See 64'-5 120 52.885 Sprinkler, Notes) 2T-3'/z 0.434 134 38'-0 233.25 2.2030 0.330106 2P0(13' 7'/2) 91'8'/z 30.273 83.591 Total(Pt) Route 4 10'-0 120 52.220 .....Route 5 209 39'-0 16.8 121.40 2 (See Sprinkler Notes) 206 39'-0 9.42 2.2030 0.000872 10'-0 0.009 206 39'-0 16.8 121.41 2 (See 10'-0 120 52.229 Sprinkler Notes) 203 39'-0 130.84 2.2030 0.113273 10'-0 1.133 203 39'-0 16.8 122.72 2 (See 68'-4 120 53.362 Sprinkler, Notes) L957 0.434 118 38'-0 253.56 2.2030 0.385232 2P0(13'-7'/z) 36.831 90.626 Total(Pt) Route 5 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 10 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 10'-0 120 52.220 •••••Route 6 209 39'-0 16.8 121.40 2 (See Sprinkler Notes) 212 39'-0 111.98 2.2030 0.084932 10'-0 0.849 212 39'-0 16.8 122.39 2 (See 64'-5 120 53.070 Sprinkler, Notes) 27'-3'/z 0.434 135 38'-0 234.36 2.2030 --r0.333022 2PO(13'-7'/z) 91'-8'/z 30.541 84.044 Total(Pt) Route 6 143 38'-0 380.01 2 (See 162'-9 120 88.259 .....Route 7 PO(13'-7'/2), Flow(q)from Notes 54'-6'/z Route 17 217'-4 4.087 125 38'-0 49.57 2.2030 0.018807 3PO(13'-7'/z) 92.345 Total(Pt) Route 7 143 38'-0 380.01 4 10'-0 120 88.259 .....Route 8 Flow(q)from Route 17 144 38'-0 330.44 4.3100 0.023937 10'-0 0.239 144 38'-0 2 (See 162'-9 120 88.498 Notes) L27 126 38'-0 50.30 2.2030 0.019323 3PO(13'-7'/z) 4.199 92.697 Total(Pt) Route 8 147 38'-0 175.10 2 (See 162'-9 120 88.869 .....Route 9 Notes) PO(13'-7'/z), Flow(q)from 54'-6'/z Route 14 129 38'-0 55.68 2.2030 217'-4 0.023319 5.068 3PO(13'-7'/z) 93.937 Total(Pt) Route 9 147 38'-0 175.10 4 10'-0 120 88.869 .....Route 10 Flow(q)from Route 14 148 38'-0 119.42 4.3100 0.003642 10'-0 0.036 148 38'-0 2 (See 162'-9 120 88.906 PO(13'-7'/z) Notes) 54'-6'/2 130 38'-0 58.28 2.2030 217'-4 0.025372 5.514 3PO(13'-7'/z) 94.419 Total(Pt) Route 10 148 38'-0 58.28 4 10'-0 120 88.906 .....Route 11 Flow(q)from Route 10 149 38'-0 61.14 4.3100 0.001055 10'-0 0.011 �{ ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 11 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 149 38'0 2 (See 162'-9 120 88.916 PO(13'-7'/2) Notes) 54'-6'/z 131 38'-0 61.14 2.2030 217'-4 0.027725 6.025 3PO(13'-7'/z) 94.941 Total(Pt) Route 11 145 38'-0 280.14 2 (See 162'-9 120 88.674 .....Route 12 PO(13'-7'/2), Flow(q)from Notes 54'-6'/z Route 15 217'-4 4.404 127 38'-0 51.61 2.2030 0.020265 3PO(13'-7'/z) 93.078 Total(Pt) Route 12 145 38'-0 280.14 4 10'-0 120 88.674 .....Route 13 Flow(q)from Route 15 146 38'-0 228.53 4.3100 0.012100 10'-0 0.121 146 38'-0 2 (See 162'-9 120 88.795 Notes) L27 128 38'-0 53.43 2.2030 0.021606 3PO(13'-7'/z) 4.695 93.491 Total(Pt) Route 13 146 38'-0 53.43 4 10'-0 120 88.795 .....Route 14 Flow(q)from Route 13 147 38'-0 175.10 4.3100 0.007393 10'-0 0.074 88.869 Total(Pt) Route 14 144 38'-0 50.30 4 10'-0 120 88.498 .....Route 15 Flow(q)from Route 8 145 38'-0 280.14 4.3100 0.017636 10'-0 0.176 88.674 Total(Pt) Route 15 142 38'-0 429.49 2 (See 162'-9 120 87.949 .....Route 16 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z Route 20 124 38'-0 49.48 2.2030 217'-4 0.018744 4.073 3PO(13'-7'/z) 92.022 Total(Pt) Route 16 142 38'-0 429.49 4 10'-0 120 87.949 .....Route 17 Flow(q)from Route 20 143 38'-0 380.01 4.3100 0.031000 10'-0 0.310 88.259 Total(Pt) Route 17 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 12 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 140 38'0 530.97 2 (See 162'-9 120 87.083 •••••Route 18 PO(13'-7'/z), Flow(q)from Notes) 54'-6'/z Route 23 122 38'-0 51.40 2.2030 217'-4 0.020115 4.371 3PO(13'-7'/z) 91.454 Total(Pt) Route 18 140 38'-0 530.97 4 10'-0 120 87.083 .....Route 19 Flow(q)from Route 23 141 38'-0 479.57 4.3100 0.047678 10'-0 0.477 141 38'-0 2 (See 162'-9 120 87.560 Notes) 54'-6'/z 123 38'-0 50.08 2.2030 217'-4 0.019167 4.165 3PO(13'-7'/z) 91.725 Total(Pt) Route 19 141 38'-0 50.08 4 10'-0 120 87.560 .....Route 20 Flow(q)from Route 19 142 38'-0 429.49 4.3100 0.038878 10'-0 0.389 87.949 Total(Pt) Route 20 138 38'-0 640.72 2 (See 162'-9 120 85.820 .....Route 21 Notes) PO(13'-7'/z), Flow(q)from 54'-6'/z Route 24 120 38'-0 56.28 2.2030 217'-4 0.023788 5.170 3PO(13'-7'/z) 90.989 Total(Pt) Route 21 138 38'-0 640.72 4 10'-0 120 85.820 .....Route 22 Flow(q)from Route 24 139 38'-0 584.44 4.3100 0.068741 10'-0 0.687 139 38'-0 2 (See 162'-9 120 86.507 Notes) L27 121 38'-0 53.47 2.2030 0.021636 3PO(13'-7'/z) 4.702 91.209 Total(Pt) Route 22 139 38'-0 53.47 4 10'-0 120 86.507 .....Route 23 Flow(q)from Route 22 140 38'-0 530.97 4.3100 0.057561 10'-0 0.576 87.083 Total(Pt) Route 23 137 38'-0 59.84 4 10'-0 120 85.005 .....Route 24 Flow(q)from Route 2 138 38'-0 640.72 4.3100 0.081487 10'-0 0.815 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 13 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 85.820 I Total(Pt) Route 24 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 4 3/31/2025 9:57:04AM Page 14 Job Name: North Sound Logistics Remote Area Number:4 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 4 3/31/2025 9:57:04AM Page 15 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 5 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 100ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1711.09 @ 57.849 (Safety Margin = 18.562) from Pump at Node: 1: 1461.09 @ 134.306 (Safety Margin = 18.562) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: 57.422 ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY ' FIRE PROTECTION SPRINKLER SYSTEMS , Brandon James Stewart N , ' 3259-0615-C-H Leve13 N , AFP Systems,Inc. o AFPSYI*091BZ o , � ��„y,�yl„�!✓�� Expires � Signature 12/31/25 , �©M.E.P.CAD �AutoSPRINK 2024 v19.0.46.0 5 3/31/2025 9:55:26AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(5) Remote Area Number:5 100 3A 82 3B 3 64 ♦----• 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Data nt Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:57.849 @ 1461.09 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):57.849 @ 1711.09 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.411 @ 1711.09 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 "n ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:55:28AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(5) Remote Area Number:5 200 7A 172 7B 144 • 1B 116 7 5A 88 5B 2A SC N Q 60 2B 5 2C 2D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:134.306 @ 1461.09 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.393 @ 1461.09 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.393 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.393 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.475 @ 1461.09 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.868 @ 1461.09 M[J©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:55:28AM Page 3 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.411 1711.09 57.849 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.868 1461.09 134.306 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 151 0'-0 Supply 57.849 1461.09 501 39'-0 Sprinkler 53.041 122.35 502 39'-0 Sprinkler 53.057 122.37 503 39'-0 Sprinkler 53.133 122.46 504 39'-0 Sprinkler 52.002 121.15 505 39'-0 Sprinkler 52.016 121.16 506 39'-0 Sprinkler 52.090 121.25 507 39'-0 Sprinkler 52.000 121.15 508 39'-0 Sprinkler 52.014 121.16 509 39'-0 Sprinkler 52.088 121.25 510 39'-0 Sprinkler 52.927 122.22 511 39'-0 Sprinkler 52.939 122.24 512 39'-0 Sprinkler 53.015 122.32 1 2'-11'/z P2 134.306 P2(-85.475) 17 2'-11'/z Gauge 133.098 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:55:31AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 113 2'-11'/2 134.209 114 2'-11'/2 P1 48.831 115 -3'-0'/2 52.343 136 3'-0 118.264 150 0'-0 57.588 193 36'-0 81.850 194 38'-0 80.996 195 38'-0 81.041 196 38'-0 81.156 197 38'-0 81.372 198 38'-0 81.605 199 38'-0 81.857 200 38'-0 82.128 213 38'-0 82.419 214 38'-0 82.731 215 38'-0 83.065 216 38'-0 83.423 217 38'-0 83.808 218 38'-0 84.222 219 38'-0 84.669 220 38'-0 85.151 221 38'-0 85.672 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:55:31AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 222 36'-0 81.413 223 36'-0 81.417 224 36'-0 81.434 225 39'-0 79.001 226 36'-0 80.262 227 36'-0 80.266 228 39'-0 78.993 229 36'-0 80.261 230 36'-0 80.268 231 36'-0 80.260 232 38'-0 79.111 233 38'-0 79.034 234 38'-0 79.313 235 38'-0 79.317 236 38'-0 78.934 237 38'-0 79.317 238 38'-0 78.807 239 38'-0 78.645 240 38'-0 78.643 241 38'-0 78.748 242 38'-0 79.175 243 38'-0 79.535 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:55:31AM Paqe 6 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 244 38'-0 79.835 245 38'-0 80.082 246 38'-0 80.280 247 38'-0 80.433 248 38'-0 80.544 249 38'-0 80.619 250 38'-0 80.662 251 38'-0 80.680 252 38'-0 80.684 253 38'-0 80.683 254 38'-0 80.698 255 38'-0 80.709 256 38'-0 79.420 257 38'-0 79.449 258 38'-0 80.435 259 38'-0 79.462 260 38'-0 80.407 261 38'-0 79.466 262 38'-0 80.393 263 38'-0 80.390 266 36'-0 80.269 267 39'-0 78.984 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:55:31AM Paqe 7 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 526 2'-1'/2 49.964 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:55:31AM Paqe 8 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 10'-0 120 52.000 •••••Route 1 507 39'-0 16.8 121.15 2 (See Sprinkler Notes) 504 39'-0 3.75 2.2030 0.000159 10'-0 0.002 504 39'-0 16.8 121.15 2 (See 10'-0 120 52.002 Sprinkler Notes) 501 39'-0 124.90 2.2030 0.103951 10'-0 1.040 501 39'-0 16.8 122.35 2 (See 47'-7 120 53.041 Sprinkler, Notes) 2T-3'/z 0.434 194 38'-0 247.26 74'-10 2.2030 27.521 0.367699 2PO(13'-7'/z) 194 38'-0 125.31 6 10'-0 120 80.996 Flow(q)from Route 7 195 38'-0 372.57 6.3570 0.004503 10'-0 0.045 195 38'-0 247.40 6 10'-0 120 81.041 Flow(q)from Route 3 196 38'-0 619.96 6.3570 0.011553 10'-0 0.116 196 38'-0 247.59 6 10'-0 120 81.156 Flow(q)from Route 5 197 38'-0 867.55 6.3570 0.021511 10'-0 0.215 197 38'-0 39.51 6 10'-0 120 81.372 Flow(q)from Route 34 198 38'-0 907.07 6.3570 0.023359 10'-0 0.234 198 38'-0 38.26 6 10'-0 120 81.605 Flow(q)from Route 28 199 38'-0 945.33 6.3570 0.025214 10'-0 0.252 199 38'-0 37.78 6 10'-0 120 81.857 Flow(q)from Route 30 200 38'-0 983.10 6.3570 0.027110 10'-0 0.271 200 38'-0 38.02 6 10'-0 120 82.128 Flow(q)from Route 29 213 38'-0 1021.12 6.3570 0.029081 10'-0 0.291 213 38'-0 38.94 6 10'-0 120 82.419 Flow(q)from Route 25 214 38'-0 1060.07 6.3570 0.031166 10'-0 0.312 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 9 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 214 38'-0 40.48 6 10'-0 120 82.731 Flow(q)from Route 26 215 38'-0 1100.55 6.3570 0.033404 10'-0 0.334 215 38'-0 42.56 6 10'-0 120 83.065 Flow(q)from Route 32 216 38'-0 1143.11 6.3570 0.035833 10'-0 0.358 216 38'-0 45.08 6 10'-0 120 83.423 Flow(q)from Route 31 217 38'-0 1188.19 6.3570 0.038491 10'-0 0.385 217 38'-0 47.97 6 10'-0 120 83.808 Flow(q)from Route 33 218 38'-0 1236.17 6.3570 0.041415 10'-0 0.414 218 38'-0 51.15 6 10'-0 120 84.222 Flow(q)from Route 4 219 38'-0 1287.31 6.3570 0.044641 10'-0 0.446 219 38'-0 54.51 6 10'-0 120 84.669 Flow(q)from Route 14 220 38'-0 1341.83 6.3570 0.048201 10'-0 0.482 220 38'-0 57.88 6 10'-0 120 85.151 Flow(q)from Route 2 221 38'-0 1399.71 6.3570 0.052118 10'-0 0.521 221 38'-0 61.38 6 (See 170'-5 120 85.672 Flow(q)from Route 27 Notes) 138'-3'/2 15.173 136 3'-0 1461.09 6.3570 308'-8%2 0.056424 17.418 3E(17'-7), CV(47'-9'/z), PO(37'- 8'/2) 136 3'-0 8 (See 759'-2'/2 120 118.264 Notes) 175'-0 0.014 17 2'-11'/2 1461.09 8.2490 0.015865 2PO(41'-1'h),3E(21'-1'/z),BV( 934'-2/2 14.821 14'-1),fE(15'-3), BOR 17 2'-11'/2 8 (See 3' 1 120 133.098 Notes) 66-11'/z -0.000 113 2'-11'/z 1461.09 8.2490 70'-0'/z 0.015865 1.111 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 1'-8'/z 120 134.209 0.000 1 2'-11'/z 1461.09 6.3570 0.056424 1'-8/z 0.097 LM ©M.E.P.CAD 411 AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 10 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to(Pf)and shown as 1 1461.09 Pump 134.306 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5-4 120 48.831 Notes) 43'-5'/2 0.359 0.015865 GV(4'-8'/2),fT(38'-9) 526 2'-1/2 1461.09 8.2490 48'-9'/2 0.774 526 2'-1'/2 10 (See 5-2 120 49.964 Notes) 20'-1 2.247 115 -3'-0'/2 1461.09 10.3700 -3'/2 0.005205 0.132 E(20'-1) 25' 115 -3'-0'/2 10 (See 176'-7 140 52.343 Notes) 149'-10'/2 -1.319 150 0'-0 1461.09 10.4000 0.003859 2E(35'-1),BFP(-5.304),T(79'- 326'-5/2 6.564 8'/2) 150 0'-0 12 (See 119'-2'/2 140 57.588 Notes) 44'-3 151 0'-0 1461.09 12.4600 0.001601 S, E(44'-3) 163'-5 0.262 250.00 57.849 Hose Allowance At Source 151 1711.09 Total(Pt) Route 1 507 39'-0 16.8 121.15 2 (See 10'-0 120 52.000 .....Route 2 Notes) Sprinkler 510 39'-0 117.39 2.2030 0.092685 10'-0 0.927 510 39'0 16.8 122.22 2 (See 45'-7 120 52.927 Sprinkler, Notes) 27'-3'/2 0.434 239 38'-0 239.61 2.2030 0.346952 25.285 2PO(13'-7'/2) 72'-10'h 239 38'-0 27.64 4 10'-0 120 78.645 Flow(q)from Route 13 238 38'-0 267.26 4.3100 0.016165 10'-0 0.162 238 38'-0 4 10'-0 120 78.807 236 38'-0 234.77 4.3100 0.012718 10'-0 0.127 236 38'-0 4 10'-0 120 78.934 233 38'-0 205.85 4.3100 0.009972 19-0 0.100 L{/©M.E.P.CAD A,]AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 11 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 233 38'-0 4 10'-0 120 79.034 232 38'-0 179.99 4.3100 0.007780 10'-0 0.078 232 38'-0 4 (See 3'-11'/2 120 79.111 Notes) 27'-10'/2 234 38'-0 160.85 4.3100 0.006318 T(27'-10'/2) 31'-10 0.201 234 38'-0 4 21'-5 120 79.313 256 38'-0 141.95 4.3100 0.005014 21'-5 0.107 256 38'-0 4 10'-0 120 79.420 257 38'-0 105.30 4.3100 0.002886 10'-0 0.029 257 38'-0 4 10'-0 120 79.449 259 38'-0 69.79 4.3100 0.001348 10'-0 0.013 259 38'-0 4 9'-0 120 79.462 261 38'-0 34.83 4.3100 0.000373 9'-0 0.003 261 38'-0 2'/2 (See 181'-8 120 79.466 Notes) 74'-10'/2 263 38'-0 34.83 2.7050 256'-6'/2 0.003602 0.924 3PO(18'-8'/2) 263 38'-0 4 91-0 120 80.390 262 38'-0 34.83 4.3100 0.000373 0.003 262 38'-0 34.96 4 10'-0 120 80.393 Flow(q)from Route 18 260 38'-0 69.79 4.3100 0.001348 10'-0 0.013 260 38'-0 35.51 4 10'-0 120 80.407 Flow(q)from Route 17 258 38'-0 105.30 4.3100 0.002886 10'-0 0.029 258 38'-0 36.65 4 (See 21'-5 120 80.435 Flow(q)from Route 16 Notes) 27-10'/2 253 38'-0 141.95 4.3100 49'-3'/2 0.005014 0.247 T(27'-10'/2) LM ©M.E.P.CAD 411 AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 12 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 253 38'-0 4 4'-3 120 80.683 254 38'-0 119.26 4.3100 0.003633 4'-3 0.016 254 38'-0 2 (See 123'-2 120 80.698 Notes) 54'-6 2 220 38'-0 57.88 2.2030 0.025053 3PO(13'-7'/z) 177'-8'/2 4.452 85.151 Total(Pt) Route 2 508 39'-0 16.8 121.16 2 (See 10'-0 120 52.014 •••••Route 3••••• Notes) Sprinkler 505 39'-0 3.86 2.2030 0.000167 10'-0 0.002 505 39'-0 16.8 121.16 2 (See 10'-0 120 52.016 Sprinkler Notes) 502 39'-0 125.03 2.2030 0.104141 10'-0 1.041 502 39'-0 16.8 122.37 2 (See 47'-7 120 53.057 Sprinkler, Notes) L74' 0.434 195 38'-0 247.40 2.2030 0.368089 2PO(13'-7'/z) 27.550 81.041 Total(Pt) Route 3 10'-0 120 52.014 •••••Route 4••••• 508 39'-0 16.8 121.16 2 (See Sprinkler Notes) 511 39'-0 117.30 2.2030 0.092552 10'-0 0.926 511 39'-0 16.8 122.24 2 (See 45'-7 120 52.939 Sprinkler, Notes) 27'-3'/z 0.434 240 38'-0 239.54 72'-10 2.2030 0.346747 25.270 2PO(13'-7'/z) '/z 240 38'-0 4 10'-0 120 78.643 241 38'-0 211.89 4.3100 0.010521 10'-0 0.105 241 38'-0 239.69 4 10'-0 120 78.748 Flow(q)from Route 6 242 38'-0 451.58 4.3100 0.042659 10'-0 0.427 242 38'-0 4 10'-0 120 79.175 243 38'-0 412.07 4.3100 0.036012 10'-0 0.360 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 13 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 243 38'-0 4 10'-0 120 79.535 244 38'-0 373.81 4.3100 0.030071 10'-0 0.301 244 38'-0 4 10'-0 120 79.835 245 38'-0 336.03 4.3100 0.024692 10'-0 0.247 245 38'-0 4 10'-0 120 80.082 246 38'-0 298.02 4.3100 0.019774 10'-0 0.198 246 38'-0 4 10'-0 120 80.280 247 38'-0 259.07 4.3100 0.015261 10'-0 0.153 247 38'-0 4 10'-0 120 80.433 248 38'-0 218.59 4.3100 0.011144 10'-0 0.111 248 38'-0 4 10'-0 120 80.544 249 38'-0 176.03 4.3100 0.007466 10'-0 0.075 249 38'-0 4 10'-0 120 80.619 250 38'-0 130.95 4.3100 0.004319 10'-0 0.043 250 38'-0 4 10'-0 120 80.662 251 38'-0 82.97 4.3100 0.001857 10'-0 0.019 251 38'-0 2 (See 123'-2 120 80.680 Notes) 54'-6'/z 218 38'-0 51.15 2.2030 177'-8'/2 0.019929 3.542 3PO(13'-7'/z) 84.222 Total(Pt) Route 4 10'-0 120 52.088 •••••Route s••••• 509 39'-0 16.8 121.25 2 (See Sprinkler Notes) 506 39'-0 3.88 2.2030 0.000169 10'-0 0.002 506 39'-0 16.8 121.25 2 (See 10'-0 120 52.090 Sprinkler Notes) 503 39'-0 125.13 2.2030 0.104304 10'-0 1.043 LA,©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 14 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 503 39'0 16.8 122.46 2 (See 47'-7 120 53.133 Sprinkler, Notes) 27'-3'/z 0.434 196 38'-0 247.59 2.2030 74'-10 27.590 0.368620 2PO(13'-7'/z) 81.156 Total(Pt) Route 5 509 39'-0 16.8 121.25 2 (See 10'-0 120 52.088 •••••Route 6••••• Notes) Sprinkler 512 39'-0 117.37 2.2030 0.092650 10'-0 0.926 512 39'-0 16.8 122.32 2 (See 45'-7 120 53.015 Sprinkler, Notes) 2T-3'/z 0.434 241 38'-0 239.69 2.2030 72'-10'/2 0.347160 25.300 2PO(13'-7'/z) 78.748 Total(Pt) Route 6 227 36'-0 38.04 2 3'-0 120 80.266 .....Route 7 PO(13'-7'/z), Flow(q)from 13'-7'/z -1.301 Route 10 225 39'-0 15.14 2.2030 0.002095 16'-7'/z 0.035 225 39'0 25.86 2 (See 29'-5'/z 120 79.001 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z 1.301 Route 23 222 36'-0 40.99 2.2030 -0% 1.112 0.013235 2E(6'-10),2PO(13'-7'/z) 84' 222 36'-0 4 8'-0 120 81.413 223 36'-0 40.99 4.3100 0.000504 0.004 223 36'-0 41.76 4 91-0 120 81.417 Flow(q)from Route 8 224 36'-0 82.76 4.3100 0.001848 9'-0 0.017 224 36'-0 42.55 4 (See 76-7 120 81.434 Flow(q)from Route 9 Notes) 27'-10'/z 193 36'-0 125.31 4.3100 104'-5'/z 0.003981 0.416 2E(13'-11) 193 36'-0 6 (See 3'-11 120 81.850 Notes) 17'-7 -0.867 194 38'-0 125.31 6.3570 0.000600 E(17'-7) 21'-6'/z 0.013 80.996 Total(Pt) Route 7 227 36'-0 38.04 4 10'-0 120 80.266 .....Route 8 Flow(q)from Route 10 230 36'-0 22.91 4.3100 0.000172 10'-0 0.002 L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 15 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 230 36'0 2 (See T-0 120 80.268 PO(13'-7'/2) Notes) 1 T-7'/2 -1.301 228 39'-0 12.84 2.2030 0.001545 16'-7'/2 0.026 228 39'-0 28.92 2 (See 2T-5'/z 120 78.993 PO(13'-7'/2), Flow(q)from Notes 54'-6'/2 1.301 Route 24 0.013697 2E(6'-10),2PO(13'-7'/2) 223 36'-0 41.76 2.2030 82'-0'/2 1.124 81.417 Total(Pt) Route 8 230 36'-0 12.84 4 9'-11 120 80.268 .....Route 9 Flow(q)from Route 8 266 36'-0 10.07 4.3100 0.000038 9'-11 0.000 266 36'-0 2 (See T-0 120 80.269 Notes) 13' 7'/2 -1.301 267 39'-0 10.07 2.2030 0.000985 0.016 267 39' 0 32.49 2 (See 26'-5'/2 120 78.984 PO(13'-7'/2), Flow(q)from Notes 54'-6'/2 1.301 Route 21 0.014182 224 36'-0 42.55 2.2030 g1'-0'/2 1.149 2E(6'-10),2PO(13'-7'/2) 81.434 Total(Pt) Route 9 226 36'-0 18.90+ 19.14 4 10'-0 120 80.262 .....Route 10 Flow(q)from Route 11 and 19 227 36'-0 38.04 4.3100 0.000439 10'-0 0.004 80.266 Total(Pt) Route 10 229 36'-0 9.43+9.47 4 10'-0 120 80.261 .....Route 11 Flow(q)from Route 12 and 22 226 36'-0 18.90 4.3100 0.000120 10'-0 0.001 80.262 Total(Pt) Route 11 231 36'-0 9.43 4 10'-0 120 80.260 .....Route 12 Flow(q)from Route 20 229 36'-0 9.43 4.3100 0.000033 10'-0 0.000 80.261 Total(Pt) Route 12 240 38'-0 211.89 4 10'-0 120 78.643 .....Route 13 Flow(q)from Route 4 239 38'-0 27.64 4.3100 0.000243 10'-0 0.002 78.645 Total(Pt) Route 13 �{ ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 16 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 251 38'-0 51.15 4 10'-0 120 80.680 .....Route 14 Flow(q)from Route 4 252 38'-0 31.82 4.3100 0.000315 10'-0 0.003 252 38'-0 22.69 2 (See 123'-2 120 80.684 PO(13'-7'/z), Flow(q)from Notes) 54'-6'/z Route 15 219 38'-0 54.51 2.2030 0.022423 3PO(13'-7'/z) 177'-8'/2 3.985 84.669 Total(Pt) Route 14 253 38'-0 119.26 4 5-9 120 80.683 .....Route 15 Flow(q)from Route 2 252 38'-0 22.69 4.3100 0.000169 5'-9 0.001 80.684 Total(Pt) Route 15 256 38'-0 2'/2 (See 18 1'-8 120 79.420 .....Route 16 Notes) 74'-10 PO(18'-8'/z) '/z 258 38'-0 36.65 2.7050 256'-6'/z 0.003958 1.015 3PO(18'-8'/z) 80.435 Total(Pt) Route 16 257 38'0 2'/2 (See 181'-8 120 79.449 .....Route 17 PO(18'-8'/z) Notes) 74'-10'/2 260 38'-0 35.51 2.7050 256'-6'/2 0.003733 0.958 3PO(18'-8'/z) 80.407 Total(Pt) Route 17 259 38'-0 2'/z (See 18 1'-8 120 79.462 .....Route 18 Notes) 74'-10 PO(18'-8'/z) '/2 262 38'-0 34.96 2.7050 256'-6'/z 0.003628 0.931 3PO(18'-8'/z) 80.393 Total(Pt) Route 18 232 38'-0 2 (See 33'-1 120 79.111 •••••Route 19••••• PO(13'-7'/z) Notes) 54'-6'/z 0.867 226 36'-0 19.14 2.2030 87'-7'/z 0.003235 0.283 3PO(13'-7'/z) 80.262 Total(Pt) Route 19 6'-0'/2 120 79.313 •••••Route 20••••• 234 38'-0 4 (See Notes) 27'-10'/2 235 38'-0 18.90 4.3100 0.000120 33'-11 0.004 235 38'-0 4 10'-0 120 79.317 237 38'-0 9.43 4.3100 0.000033 10'-0 0.000 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 17 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 237 38'0 2 (See 33'-1 120 79.317 PO(13'-7'/2) Notes) 54'-6'/z 0.867 231 36'-0 9.43 2.2030 87'-7'/z 0.000873 0.076 3PO(13'-7'/z) 80.260 Total(Pt) Route 20 238 38'-0 2 (See 30'-1 120 78.807 .....Route 21 Notes) PO(13'-7'/z) 40'-11 -0.434 267 39'-0 32.49 2.2030 71' 0 0.008608 0.611 2PO(13'-7'/z) 78.984 Total(Pt) Route 21 33'-1 120 79.317 •••••Route 22••••• 235 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 0.867 229 36'-0 9.47 2.2030 87'-7'/z 0.000880 0.077 3PO(13'-7'/z) 80.261 Total(Pt) Route 22 233 38'-0 2 (See 30'-1 120 79.034 .....Route 23 PO(13'-7'/z) Notes) 40'-11 -0.434 225 39'-0 25.86 2.2030 71' 0 0.005642 0.401 2PO(13'-7'/z) 79.001 Total(Pt) Route 23 30'-1 120 78.934 .....Route 24 236 38'-0 2 (See Notes) PO(13'-7'/z) 40'-11 -0.434 228 39'-0 28.92 2.2030 71'-0 0.006942 0.493 2PO(13'-7'/z) 78.993 Total(Pt) Route 24 246 38'-0 2 (See 123'-2 120 80.280 .....Route 25 PO(13'-7'/z) Notes) 54'-6'/z 213 38'-0 38.94 2.2030 177'-8'/2 0.012036 2.139 3PO(13'-7'/z) 82.419 Total(Pt) Route 25 247 38' 0 2 (See 123'-2 120 80.433 .....Route 26 PO(13'-7'/2) Notes) 54'-6'/z 214 38'-0 40.48 2.2030 177'-8'/2 0.012931 2.298 3PO(13'-7'/2) 82.731 Total(Pt) Route 26 254 38'-0 57.88 4 10'-0 120 80.698 .....Route 27 Flow(q)from Route 2 255 38'-0 61.38 4.3100 0.001063 10'-0 0.011 L{/©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 18 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 255 38'0 2 (See 123'-2 120 80.709 PO(13'-7'/z) Notes) 54'-6'/z 221 38'-0 61.38 2.2030 177'-8'/z 0.027926 4.963 3PO(13'-7'/z) 85.672 Total(Pt) Route 27 243 38'-0 2 (See 123'-2 120 79.535 .....Route 28 Notes) 54'-6 PO(13'-7'/z) '/z 198 38'-0 38.26 2.2030 177'-8'/z 0.011650 2.070 3PO(13'-7'/z) 81.605 Total(Pt) Route 28 123'-2 120 80.082 .....Route 29 245 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 200 38'-0 38.02 2.2030 177'-8'/z 0.011513 2.046 3PO(13'-7'/z) 82.128 Total(Pt) Route 29 123'-2 120 79.835 .....Route 30 244 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 199 38'-0 37.78 2.2030 177'-8'/z 0.011377 2.022 3PO(13'-7'/z) 81.857 Total(Pt) Route 30 123'-2 120 80.619 •••••Route 31 ••••• 249 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 216 38'-0 45.08 2.2030 177'-8'/z 0.015780 2.804 3PO(13'-7'/z) 83.423 Total(Pt) Route 31 248 38'-0 2 (See 123'-2 120 80.544 .....Route 32 PO(13'-7'/z) Notes) 54'-6'/z 215 38'-0 42.56 2.2030 177'-8'/z 0.014184 2.521 3PO(13'-7'/z) 83.065 Total(Pt) Route 32 250 38'-0 2 (See 123'-2 120 80.662 .....Route 33 PO(13'-7'/z) Notes) 54'-6'/z 217 38'-0 47.97 2.2030 177'-8'/z 0.017703 3.146 3PO(13'-7'/2) 83.808 Total(Pt) Route 33 242 38'-0 2 (See 123'-2 120 79.175 •••••Route 34••••• PO(13'-7'/z) Notes) 54'-6'/z 197 38'-0 39.51 2.2030 177'-8'/z 0.012362 2.197 3PO(13'-7'/z) 81.372 Total(Pt) Route 34 LM ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 5 3/31/2025 9:55:34AM Page 19 Job Name: North Sound Logistics Remote Area Number: 5 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 5 3/31/2025 9:55:34AM Page 20 Hydraulic Calculations for Project Name: North Sound Logistics: (25034) Location: , , Drawing Name: Northsound Logistics Submittal Calculation Date: 3/31/2025 Design Remote Area Number: 6 Occupancy Classification: ESFR Pressure 52.000 Area of Application: NA Coverage per Sprinkler: 100ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 12 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 250.00 at Node: 151 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 151: 1709.15 @ 57.379 (Safety Margin = 19.061) from Pump at Node: 1: 1459.15 @ 133.874 (Safety Margin = 19.061) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent System: N/A for Node: 151 Date: Location: Source: City of Arlington Public Works Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: 57.574 Right: 57.058 ,--------------------------- Summary Notes: WASHINGTON STATE CERTIFICATE OF COMPETENCY ' FIRE PROTECTION SPRINKLER SYSTEMS ' , Brandon James Stewart N , ' 3259-0615-C-H Leve13 N , AFP Systems,Inc. o:: AFPSYI*091 BZ o , � jjpy, � Expires � Signature 12/31/25 , ---------------------------' �©M.E.P.CAD �AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:37AM Pagel W—J I Hydraulic Graph Water Supply at Node 151 System Demand pp y � Available Water Supply Job Name:North Sound Logistics Job Number:25034 Report Description:ESFR(6) Remote Area Number:6 100 3A 82 36 3 64 1B 1C 3C 46 28 N Q �' 10 w a� a _g -26 -44 -62 -80 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Curve Data nt Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:57.379 @ 1459.15 Available Flow @ 20 PSI: 4149.26 mRequired Pressure at System Demand(Including Hose Allowance at Source):57.379 @ 1709.15 ® m Available Static Pressure at Water Supply at Node 151:90.000 m Available Residual Pressure at System Demand:76.440 @ 1709.15 m Available Residual Pressure&Flow at Water Supply at Node 151:48.000 @ 3149.00 An ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:54:40AM Page 2 �.J Hydraulic Graph Pumpat Node 1 System Demand � Available Water Supply @Pump Inlet Job Name:North Sound Logistics Fire Pump Supply Combined Supply Job Number:25034 Report Description:ESFR(6) Remote Area Number:6 200 7A 172 76 144 • 1B 116 7 5A 88 56 2A C N Q 60 2B 5 2C 12D a� a 32 4 -24 -52 -80 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Curve Pain Hydraulic Calculation Results Additional Data m Required Pressure at System Demand:133.874 @ 1459.15 Fire Pump Rating:85.000 @ 1500.00 ® m Available Static Pressure at Pump Inlet:88.713 m Available Residual Pressure at System Demand at Pump Inlet:66.437 @ 1459.15 m Available Residual Pressure at Pump Rated Flow at Pump Inlet 66.437 @ 1500.00 mi Available Residual Pressure at 150%of Rated Pump Capacity at Pump Inlet:66.437 @ 2250.00 © m Fire Pump Chum Pressure:95.000 m Available Residual Pressure at System Demand:85.498 @ 1459.15 m Fire Pump Rating:85.000 @ 1500.00 m Available Static Pressure:183.713 m Available Pressure at System Demand 152.935 @ 1459.15 LM ©M.E.P.CAD ®AutoSPRINK 2024 v19.0.46.0 3/31/2025 9:54:40AM Page 3 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Supply Analysis Static Residual Flow Available Total Demand Required Pressure Node Name (psi) (psi) co (gpm) (psi) @ (gpm) (psi) 151 Water Supply 90.000 48.000 3149.00 76.440 1709.15 57.379 Pump Analysis Churn Residual @ Flow Available @ Total Demand Required Pressure Node (psi) (Psi) (gPm) (Psi) (gPm) (Psi) 1 95.000 85.000 1500.00 152.935 1459.15 133.874 Node Analysis Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (Psi) (gpm) 151 0'-0 Supply 57.379 1459.15 301 39'-0 Sprinkler 52.756 122.02 302 39'-0 Sprinkler 52.490 121.72 303 39'-0 Sprinkler 52.364 121.57 304 39'-0 Sprinkler 52.098 121.26 305 39'-0 Sprinkler 52.502 121.73 306 39'-0 Sprinkler 52.267 121.46 307 39'-0 Sprinkler 52.000 121.15 308 39'-0 Sprinkler 52.109 121.27 309 39'-0 Sprinkler 52.981 122.28 310 39'-0 Sprinkler 52.011 121.16 311 39'-0 Sprinkler 52.580 121.82 312 39'-0 Sprinkler 52.481 121.71 1 2'-11'/z P2 133.874 P2(-85.498) 17 2'-11'/z Gauge 132.669 L@ M.E.P.CAD ]AutoSPRINK 2024 09.0.46. 3/31/2025 9:54:43AM Paqe 4 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 113 2'-11'/2 133.777 114 2'-11'/2 P1 48.376 115 -3'-0'/2 51.885 136 3'-0 117.871 150 0'-0 57.118 193 36'-0 82.866 194 38'-0 82.050 195 38'-0 82.087 196 38'-0 82.139 197 38'-0 82.208 198 38'-0 82.296 199 38'-0 82.406 200 38'-0 82.540 213 38'-0 82.700 214 38'-0 82.889 215 38'-0 83.110 216 38'-0 83.367 217 38'-0 83.661 218 38'-0 83.999 219 38'-0 84.384 220 38'-0 84.823 221 38'-0 85.322 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:54:43AM Paqe 5 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 222 36'-0 81.131 223 36'-0 81.148 224 36'-0 81.215 225 39'-0 75.262 226 36'-0 76.286 227 36'-0 76.341 228 39'-0 75.385 229 36'-0 76.258 230 36'-0 76.371 231 36'-0 76.251 232 38'-0 73.905 233 38'-0 74.494 234 38'-0 73.634 235 38'-0 73.650 236 38'-0 74.991 237 38'-0 73.657 238 38'-0 75.419 239 38'-0 75.796 240 38'-0 76.066 241 38'-0 76.248 242 38'-0 76.358 243 38'-0 76.414 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:54:43AM Paqe 6 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 244 38'-0 76.433 245 38'-0 76.434 246 38'-0 76.425 247 38'-0 76.387 248 38'-0 76.297 249 38'-0 76.136 250 38'-0 75.881 251 38'-0 75.507 252 38'-0 74.988 253 38'-0 74.588 254 38'-0 74.622 255 38'-0 74.645 256 38'-0 69.069 257 38'-0 68.176 258 38'-0 68.909 259 38'-0 67.755 260 38'-0 67.719 261 38'-0 67.650 262 38'-0 67.160 263 38'-0 67.020 266 36'-0 76.380 267 39'-0 75.503 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:54:43AM Paqe 7 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Node Number Elevation(Foot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 526 2'-1'/2 49.507 L@ M.E.P.CAD ]AutoSPRINK 2024 v19.0.46. 3/31/2025 9:54:43AM Paqe 8 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 307 39'-0 16.8 121.15 2'/2 (See 10'-0 120 52.000 .....Route 1 Sprinkler Notes) 310 39'-0 18.37 2.7050 0.001103 10'-0 0.011 310 39'-0 16.8 121.16 2'/2 (See 10'-0 120 52.011 Sprinkler Notes) 312 39'-0 139.53 2.7050 0.046951 10'-0 0.470 312 39'-0 16.8 121.71 2'/2 (See 56'-9 120 52.481 Notes) Sprinkler, 37'-5 0.434 263 38'-0 261.24 94'-2 2.7050 14.106 0.149801 2PO(18'-8'/2) 263 38'-0 4 91-0 120 67.020 262 38'-0 261.24 4.3100 0.015498 0.139 262 38'-0 261.63 4 10'-0 120 67.160 Flow(q)from Route 3 260 38'-0 522.87 4.3100 0.055947 10'-0 0.559 260 38'-0 263.22 4 10'-0 120 67.719 Flow(q)from Route 5 258 38'-0 786.09 4.3100 0.118953 10'-0 1.190 258 38'-0 4 (See 21'-5 120 68.909 Notes) 27'-10'/2 253 38'-0 772.59 4.3100 49'-3'/2 0.115201 5.679 T(27'-10'/2) 253 38'-0 4 4'-3 120 74.588 254 38'-0 183.47 4.3100 0.008060 4'-3 0.034 254 38'-0 2 (See 123'-2 120 74.622 Notes) 54'-6'/2 220 38'-0 90.60 2.2030 177'-8'/2 0.057399 10.201 3PO(13'-7'/2) 220 38'-0 1275.68 6 10'-0 120 84.823 Flow(q)from Route 2 221 38'-0 1366.28 6.3570 0.049838 10'-0 0.498 221 38'-0 92.86 6 (See 170'-5 120 85.322 Flow(q)from Route 29 Notes) 138'-3'/2 15.173 136 3'-0 1459.15 6.3570 308'8'/2 0.056286 17.376 3E(17'-7),CV(47'-9'/z), PO(37'- 8'/2) LM ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 9 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 136 3'-0 g (See 759'-2'/2 120 117.871 Notes) 175'-0 0.014 17 2'-11'/2 1459.15 8.2490 0.015826 2PO(41'-1'/2),3E(21'-1'/2),BV( 934'-2%2 14.784 14'-1),fE(15'-3), BOR 17 2'-11'/2 8 (See 3' 1 120 132.669 Notes) 66-11'/2 -0.000 113 2'-11'/z 1459.15 8.2490 70'-0'/z S 826 1.108 BV(14'-1),sCV(52'-10) 113 2'-11'/2 6 V-8'/2 120 133.777 0.000 1 2'-11'/2 1459.15 6.3570 0.056286 1'-8'/z 0.097 1 1459.15 Pump 133.874 Rating:85.000 @ 1500.00 114 Fire Pump Churn Pressure: 95.000 114 2'-11'/2 8 (See 5'-4 120 48.376 Notes) 43'-5'/2 0.359 526 2'-1'/2 1459.15 8.2490 48' 9'/2 0.015826 0.772 GV(4'-8'/2),fT(38'-9) 526 2'-1'/2 10 (See 5'2 120 49.507 Notes) 20'-1 2.247 115 -3'-0'/2 1459.15 10.3700 0.005193 0.131 E(20'-1) 25'-3%2 115 -3'-0'/2 10 (See 176'-7 140 51.885 Notes) 149'-10'/2 -1.319 150 0'-0 1459.15 10.4000 326'-5/z 0.003850 6.551 2E(35'-1),BFP(-5.295),T(79'- 8'/z) 150 0'-0 12 (See 119'-2'/2 140 57.118 Notes) 44'-3 151 0'-0 1459.15 12.4600 0.001597 S, E(44'-3) F163'-5 0.261 250.00 57.379 Hose Allowance At Source 151 1709.15 Total(Pt) Route 1 307 39'-0 16.8 121.15 2'/2 (See 10'-0 120 52.000 •••••Route 2••••• Notes) Sprinkler 306 39'-0 102.77 2.7050 0.026667 10'-0 0.267 306 39'-0 16.8 121.46 2'/2 (See 94'-11'/2 120 52.267 Notes) Sprinkler, 37'-5 0.434 132'-4'/z 261 38'-0 224.23 2.7050 0.112923 14.949 2PO(18'-8'/2) &©M.E.P.CAD A]AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 10 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 261 38'-0 4 91-0 120 67.650 259 38'-0 224.23 4.3100 0.011682 9'-0 0.105 259 38'-0 224.29 4 10'-0 120 67.755 Flow(q)from Route 4 257 38'-0 448.52 4.3100 0.042126 10'-0 0.421 257 38'-0 224.53 4 10'-0 120 68.176 Flow(q)from Route 6 256 38'-0 673.05 4.3100 0.089257 10'-0 0.893 256 38'-0 13.50 4 (See 21'-5 120 69.069 Notes) 27'-10'/2 Flow(q)from Route 19 234 38'-0 686.55 4.3100 0.092597 T(27'-10'/z) 49'-3'/z 4.565 234 38'-0 4 3'-11'/z 120 73.634 232 38'-0 584.66 4.3100 0.068789 3'-11'/z 0.272 232 38'-0 4 10'-0 120 73.905 233 38'-0 537.32 4.3100 0.058842 10'-0 0.588 233 38'-0 4 10'-0 120 74.494 236 38'-0 490.50 4.3100 0.049708 10'-0 0.497 236 38'-0 4 10'-0 120 74.991 238 38'-0 452.22 4.3100 0.042770 10'-0 0.428 238 38'-0 4 10'-0 120 75.419 239 38'-0 422.51 4.3100 0.037718 10'-0 0.377 239 38'-0 4 10'-0 120 75.796 240 38'-0 352.96 4.3100 0.027042 10'-0 0.270 240 38'-0 4 10'-0 120 76.066 241 38'-0 284.82 4.3100 r- 0.018185 10'-0 0.182 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 11 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 241 38'-0 4 10'-0 120 76.248 242 38'-0 217.49 4.3100 0.011041 10'-0 0.110 242 38'-0 4 10'-0 120 76.358 243 38'-0 150.41 4.3100 0.005581 10'-0 0.056 243 38'-0 4 10'-0 120 76.414 244 38'-0 83.13 4.3100 0.001863 10'-0 0.019 244 38'-0 4 10'-0 120 76.433 245 38'-0 15.28 4.3100 0.000081 10'-0 0.001 245 38'-0 53.37 2 (See 123'-2 120 76.434 PO(13'-7'/z), Flow(q)from Notes) 54'-6'/z Route 13 200 38'-0 68.66 2.2030 177'-8'/2 0.034357 6.106 3PO(13'-7'/z) 200 38'-0 671.27 6 10'-0 120 82.540 Flow(q)from Route 7 213 38'-0 739.92 6.3570 0.016025 10'-0 0.160 213 38'-0 69.67 6 10'-0 120 82.700 Flow(q)from Route 27 214 38'-0 809.60 6.3570 0.018928 10'-0 0.189 214 38'-0 71.03 6 10'-0 120 82.889 Flow(q)from Route 14 215 38'-0 880.63 6.3570 0.022115 10'-0 0.221 215 38'-0 72.84 6 10'-0 120 83.110 Flow(q)from Route 32 216 38'-0 953.47 6.3570 0.025617 10'-0 0.256 216 38'-0 75.22 6 10'-0 120 83.367 Flow(q)from Route 16 217 38'-0 1028.69 6.3570 0.029481 10'-0 0.295 217 38'-0 78.26 6 10'-0 120 83.661 Flow(q)from Route 34 218 38'-0 1106.95 6.3570 0.033764 10'-0 0.338 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 12 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 218 38'-0 82.05 6 10'-0 120 83.999 Flow(q)from Route 15 219 38'-0 1189.01 6.3570 0.038539 10'-0 0.385 219 38'-0 86.67 6 10'-0 120 84.384 Flow(q)from Route 17 220 38'-0 1275.68 6.3570 0.043897 10'-0 0.439 84.823 Total(Pt) Route 2 304 39'-0 16.8 121.26 2'/z (See 10'-0 120 52.098 .....Route 3 Notes) Sprinkler 308 39'-0 18.54 2.7050 0.001122 10'-0 0.011 308 39'-0 16.8 121.27 2'/z (See 10'-0 120 52.109 Sprinkler Notes) 311 39'-0 139.81 2.7050 0.047126 10'-0 0.471 311 39'-0 16.8 121.82 2% (See 56-9 120 52.580 Notes) Sprinkler, 37'-5 0.434 262 38'-0 261.63 2.7050 0.150222 2PO(18'-8'/z) 94'-2 14.146 67.160 Total(Pt) Route 3 304 39'-0 16.8 121.26 2'/2 (See 10'-0 120 52.098 .....Route 4 Sprinkler Notes) 303 39'-0 102.72 2.7050 0.026642 10'-0 0.266 303 39'-0 16.8 121.57 2'/2 (See 94'-11'/z 120 52.364 Notes) Sprinkler, 37'-5 0.434 259 38'-0 224.29 2.7050 132'-4'/z 0.112980 14.957 2PO(18'-8'/z) 67.755 Total(Pt) Route 4 10'-0 120 52.490 .....Route 5 302 39'-0 16.8 121.72 2% (See Sprinkler Notes) 305 39'-0 19.21 2.7050 0.001198 10'-0 0.012 305 39'-0 16.8 121.73 2% (See 10'-0 120 52.502 Sprinkler Notes) 309 39'-0 140.94 2.7050 0.047830 10'-0 0.478 309 39'-0 16.8 122.28 2'/2 (See 56-9 120 52.981 Notes) Sprinkler, 37-5 0.434 260 38'-0 263.22 2.7050 94'-2 14.305 0.151913 2PO(18'-8'/z) L{/©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 13 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 67.719 I Total(Pt) Route 5 10'-0 120 52.490 •••••Route 6••••• 302 39'-0 16.8 121.72 2% (See Sprinkler Notes) 301 39'-0 102.51 2.7050 0.026540 10'-0 0.265 301 39'-0 16.8 122.02 2% (See 94'-11'/2 120 52.756 Notes) Sprinkler, 37'-5 0.434 132'-4'/2 257 38'-0 224.53 2.7050 0.113205 14.987 2PO(18'-8'/z) 68.176 Total(Pt) Route 6 227 36'-0 149.23 2 3'-0 120 76.341 .....Route 7 PO(13'-7'/z), Flow(q)from 13'-7'/z -1.301 Route 10 225 39'-0 41.16 2.2030 0.013334 16'-7% 0.222 225 39'-0 46.83 2 (See 29'-5'/z 120 75.262 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z 1.301 Route 24 222 36'-0 87.99 2.2030 84'-0% 4.569 0.054367 2E(6'-10)1 2PO(13'-7'/z) 222 36'-0 4 8'-0 120 81.131 223 36'-0 87.99 4.3100 0.002070 8'-0 0.017 223 36'-0 88.01 4 91-0 120 81.148 Flow(q)from Route 8 224 36'-0 175.99 4.3100 0.007463 9'-0 0.067 224 36'-0 88.05 4 (See 76-7 120 81.215 Flow(q)from Route 9 Notes) 27'-10'/z 193 36'-0 264.04 4.3100 104'-5'/z 0.015807 1.651 2E(13'-11) 193 36'-0 6 (See 3'-11 120 82.866 Notes) 17'-7 -0.867 194 38'-0 264.04 6.3570 0.002382 0.051 E(17'-7) 194 38'-0 69.55 6 10'-0 120 82.050 Flow(q)from Route 26 195 38'-0 333.60 6.3570 0.003671 10'-0 0.037 195 38'-0 68.14 6 10'-0 120 82.087 Flow(q)from Route 33 196 38'-0 401.73 6.3570 0.005177 10'-0 0.052 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 14 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 196 38'-0 67.34 6 10'-0 120 82.139 Flow(q)from Route 28 197 38'-0 469.07 6.3570 0.006896 10'-0 0.069 197 38'-0 67.08 6 10'-0 120 82.208 Flow(q)from Route 35 198 38'-0 536.15 6.3570 0.008831 10'-0 0.088 198 38'-0 67.28 6 10'-0 120 82.296 Flow(q)from Route 30 199 38'-0 603.43 6.3570 0.010989 10'-0 0.110 199 38'-0 67.84 6 10'-0 120 82.406 Flow(q)from Route 31 200 38'-0 671.27 6.3570 0.013384 10'-0 0.134 82.540 Total(Pt) Route 7 227 36'-0 149.23 4 10'-0 120 76.341 .....Route 8 Flow(q)from Route 10 230 36'-0 108.07 4.3100 0.003028 10'-0 0.030 230 36'-0 2 (See 3'-0 120 76.371 Notes) 13'-7'/z -1.301 228 39'-0 49.73 2.2030 0.018919 16'-7'/2 0.315 228 39'-0 38.28 2 (See 27'-5'/z 120 75.385 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z 1.301 Route 25 0.054393 223 36'-0 88.01 2.2030 g2'-0'/z 4.462 2E(6'-10),2PO(13'-7'/2) 81.148 Total(Pt) Route 8 230 36'-0 49.73 4 9'-11 120 76.371 .....Route 9 Flow(q)from Route 8 266 36'-0 58.34 4.3100 0.000968 9'-11 0.010 266 36'-0 2 (See 3'-0 120 76.380 Notes) 13' 7'/z -1.301 267 39'-0 58.34 2.2030 0.025422 0.423 267 39'-0 29.71 2 (See 26'-5'/z 120 75.503 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z 1.301 Route 22 0.054439 224 36'-0 88.05 2.2030 g1'-0'/z 4.411 2E(6'-10)1 2PO(13'-7'/z) 81.215 Total(Pt) Route 9 LM ©M.E.P.CAD ]AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 15 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 Actual ID Length Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to(Pf)and shown as 226 36'-0 101.90+47.33 4 10'-0 120 76.286 .....Route 10 Flow(q)from Route 11 and 20 227 36'-0 149.23 4.3100 0.005500 10'-0 0.055 76.341 Total(Pt) Route 10 229 36'-0 50.83+51.07 4 10'-0 120 76.258 .....Route 11 Flow(q)from Route 12 and 23 226 36'-0 101.90 4.3100 0.002715 10'-0 0.027 76.286 Total(Pt) Route 11 231 36'-0 50.83 4 10'-0 120 76.251 .....Route 12 Flow(q)from Route 21 229 36'-0 50.83 4.3100 0.000750 10'-0 0.007 76.258 Total(Pt) Route 12 247 38'-0 4 10'-0 120 76.387 .....Route 13 246 38'-0 123.04 4.3100 0.003849 10'-0 0.038 246 38'-0 4 10'-0 120 76.425 245 38'-0 53.37 4.3100 0.000821 19-0 0.008 76.434 Total(Pt) Route 13 249 38'-0 4 10'-0 120 76.136 •••••Route 14••••• 248 38'-0 266.91 4.3100 0.016126 10'-0 0.161 248 38'-0 4 10'-0 120 76.297 247 38'-0 194.07 4.3100 0.008943 10'-0 0.089 247 38'-0 2 (See 123'-2 120 76.387 Notes) 54'-6'/2 214 38'-0 71.03 2.2030 0.036587 3PO(13'-7'/z) 177'-8'/2 6.502 82.889 Total(Pt) Route 14 251 38'0 502.45 2 (See 123'-2 120 75.507 .....Route 15 PO(13'-7'/z), Flow(q)from Notes 54'-6'/z Route 18 218 38'-0 82.05 2.2030 177'-8'/2 0.047781 8.492 3PO(13'-7'/z) 83.999 Total(Pt) Route 15 LM ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 16 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 251 38'-0 502.45 4 10'-0 120 75.507 .....Route 16 Flow(q)from Route 18 250 38'-0 420.40 4.3100 0.037370 10'-0 0.374 250 38'-0 4 10'-0 120 75.881 249 38'-0 342.14 4.3100 0.025528 10'-0 0.255 249 38'-0 2 (See 123'-2 120 76.136 Notes) 54'-6'/z 216 38'-0 75.22 2.2030 0.040683 3PO(13'-7'/z) 177'-8'/2 7.230 83.367 Total(Pt) Route 16 253 38'-0 183.47 4 5-9 120 74.588 .....Route 17 Flow(q)from Route 1 252 38'-0 589.12 4.3100 0.069764 5-90.400 252 38'-0 2 (See 123'-2 120 74.988 Notes) 54'-6'/z 219 38'-0 86.67 2.2030 0.052874 3PO(13'-7'/z) 177'-8'/2 9.397 84.384 Total(Pt) Route 17 252 38'-0 86.67 4 10'-0 120 74.988 .....Route 18 Flow(q)from Route 17 251 38'-0 502.45 4.3100 0.051973 10'-0 0.520 75.507 Total(Pt) Route 18 258 38'-0 2'/z (See 181'-8 120 68.909 Notes) 74'-10'/2 256 38'-0 13.50 2.7050 256'-6'/2 0.000624 0.160 3PO(18'-8'/z) 69.069 Total(Pt) Route 19 33'-1 120 73.905 .....Route 20 232 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/2 0.867 226 36'-0 47.33 2.2030 87'-7'/2 0.017268 1.513 3PO(13'-7'/z) 76.286 Total(Pt) Route 20 234 38'0 584.66 4 6'-0'/z 120 73.634 .....Route 21 Flow(q)from Route 2 235 38'-0 101.90 4.3100 0.002715 6'-0/z 0.016 �{ ©M.E.P.CAD AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 17 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length(Foot) Total (psi) ( Friction(Pf) directly to(Pf)and shown as (Foot) 235 38'-0 4 10'-0 120 73.650 237 38'-0 50.83 4.3100 0.000750 10'-0 0.007 237 38'-0 2 (See 33'-1 120 73.657 Notes) 54'-6'/z 0.867 231 36'-0 50.83 2.2030 0.019700 3PO(13'-7'/z) 8 7 2 1.726 76.251 Total(Pt) Route 21 238 38'-0 2 (See 30'-1 120 75.419 .....Route 22 Notes) PO(13'-7'/z) 40'-11 -0.434 267 39'-0 29.71 2.2030 71' 0 0.007295 0.518 2PO(13'-7'/z) 75.503 Total(Pt) Route 22 235 38'-0 2 (See 33'-1 120 73.650 .....Route 23 PO(13'-7'/z) Notes) 54'-6'/z 0.867 229 36'-0 51.07 2.2030 87'-7'/z 0.019872 1.741 3PO(13'-7'/z) 76.258 Total(Pt) Route 23 30'-1 120 74.494 .....Route 24 233 38'-0 2 (See PO(13'-7'/z) Notes) 40'-11 -0.434 225 39'-0 46.83 2.2030 71' 0 0.016926 1.202 2PO(13'-7'/z) 75.262 Total(Pt) Route 24 30'-1 120 74.991 •••••Route 25••••• 236 38'-0 2 (See Notes) PO(13'-7'/z) 40'-11 -0.434 228 39'-0 38.28 2.2030 71'-0 0.011659 0.828 2PO(13'-7'/z) 75.385 Total(Pt) Route 25 239 38'-0 2 (See 123'-2 120 75.796 .....Route 26 PO(13'-7'/z) Notes) 54'-6'/z 194 38'-0 69.55 2.2030 177'-8'/2 0.035192 6.255 3PO(13'-7'/z) 82.050 Total(Pt) Route 26 246 38' 0 2 (See 123'-2 120 76.425 .....Route 27 PO(13'-7'/z) Notes) 54'-6'/z 213 38'-0 69.67 2.2030 177'-8'/z 0.035305 6.275 3PO(13'-7'/z) 82.700 Total(Pt) Route 27 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 18 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 123'-2 120 76.248 .....Route 28 241 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/z 196 38'-0 67.34 2.2030 177'-8'/2 0.033146 5.891 3PO(13'-7'/z) 82.139 Total(Pt) Route 28 254 38'-0 90.60 4 10'-0 120 74.622 .....Route 29 Flow(q)from Route 1 255 38'-0 92.86 4.3100 0.002287 10'-0 0.023 255 38'-0 2 (See 123'-2 120 74.645 Notes) 54'-6'/z 221 38'-0 92.86 2.2030 177'-8'/2 0.060074 10.677 3PO(13'-7'/z) 85.322 Total(Pt) Route 29 243 38'-0 2 (See 123'-2 120 76.414 •••••Route 30••••• PO(13'-7'/z) Notes) 54'-6'/z 198 38'-0 67.28 2.2030 177'-8'/z 0.033095 5.882 3PO(13'-7'/z) 82.296 Total(Pt) Route 30 123'-2 120 76.433 .....Route 31 244 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/z 199 38'-0 67.84 2.2030 177'-8'/2 0.033609 5.973 3PO(13'-7'/z) 82.406 Total(Pt) Route 31 123'-2 120 76.297 .....Route 32 248 38'-0 2 (See PO(13'-7'/z) Notes) 54'-6'/2 215 38'-0 72.84 2.2030 177'-8'/2 0.038334 6.813 3PO(13'-7'/z) 83.110 Total(Pt) Route 32 240 38'-0 2 (See 123'-2 120 76.066 .....Route 33 PO(13'-7'/z) Notes) 54'-6'/z 195 38'-0 68.14 2.2030 177'-8'/2 0.033877 6.021 3PO(13'-7'/z) 82.087 Total(Pt) Route 33 250 38' 0 2 (See 123'-2 120 75.881 .....Route 34 PO(13'-7'/2) Notes) 54'-6'/z 217 38'-0 78.26 2.2030 177'-8'/z 0.043778 7.780 3PO(13'-7'/z) 83.661 Total(Pt) Route 34 L{/©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 19 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (q) Fitting Length) pf Friction Elev(Pe) Fixed Pressure Losses, Elev 2 Total Flow Equiv. (Foot) Loss Per Unit when applicable,are added Node 2 (Foot) (Q) Actual ID Length g) (Foot)Total (psi) ( Friction(Pf) directly to(Pf)and shown as 123'-2 120 76.358 .....Route 35 242 38'-0 2 (See PO(13'-7'/2) Notes) 54'-6'/z 197 38'-0 67.08 2.2030 177'-8'/2 0.032912 5.849 3PO(13'-7'/z) 82.208 Total(Pt) Route 35 �{ ©M.E.P.CAD ��AutoSPRINK 2024 09.0.46.0 6 3/31/2025 9:54:46AM Page 20 Job Name: North Sound Logistics Remote Area Number: 6 Date: 3/31/2025 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back-flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90'Elbow EE 45'Elbow Eel 11'/4'Elbow Eel 22'/2'Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90'FireLock(TM)Elbow fEE 45'FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �{ ©M.E.P.CAD ,4�AutoSPRINK 2024 vl9.0.46.0 6 3/31/2025 9:54:46AM Page 21 ICE et Capitol Pump Resources 3/31/2025 PEERLESS • 6891 Mullen Rd SE Lacey,WA 98503 PUMP" �I 360-493-1830 Peerless Express 24.6.5 Customer • Only Project name North Sound Logistics Quote Number/ID 25041880 Customer AFP Systems Inc. Model/Stages 6AEF14G/1 Tag Number 001 Flow,rated 1,500 USgpm Customer ref./PO Differential head/pressure, 85.00 psi rated Speed,rated 2100 rpm Qty Description 1 6AEF14G Fire Pump System Mount PumpType:New Pump Scope of Supply:Fire Pump with driver and controller Pump 1 Pump model:6AEF14G Selected pump listing: FM/UL Listed 1 Casing material:Cast Iron Suction flange: 1251b ANSI Flat faced Discharge flange:2501b ANSI Flat faced Casing ring:Bismuth tin bronze Impeller material:Silicon Brass Impeller Wear Ring:Integral Rotation:Clockwise(RH) Bearing solution:Single row outboard grease lube bearing Shaft material:Carbon steel 2 Shaft sleeve material:304SS with O-ring 1 Lantern Ring:Lantern ring with seal piping Packing type:Standard Nameplate units:US 1 Coating:Standard Red Enamel Testing scription 1 Fire Pump System Pump Testing Performance Tests Performance Tests:Non-witnessed Performance Test Hydrostatic Pressure Tests Hydrostatic Pressure Tests:Non-witnessed Hydrostatic Test Driver Qty Description 71 1 Fire Pump System Pump Baseplate design: Non drip rim CAPITOL PUMP RESOURCES INC. -5891 Mullen Road SE Lacey,WA 98503 phone: 360-493-1830 fax:360-923-1841 Page 1 of 5 �PEERLESS Peerless Express 24.6.5 Driver Qty Descriptio Driver Type Engine manufacturer:All engines Engine cooling type: Heat exchanger cooled Pressure limiting:No Emission tier:Any 1 Engine:Clarke JU4H-UFADRO, 136hp,2100rpm, Emission tier level T3 1 Engine voltage: 12 Volt DC 1 Cooling loop:FM Steel Cooling loop 1 Drive shaft:UL Listed drive-shaft,flywheel adapter,companion flange,&guard Water jacket heater voltage: 115/120 VAC Flexible exhaust connector:4"150#Flex Exhaust Standard Size Battery kits 1 Battery kits:Battery Racks and Cables 1 EIEO Silencer:4 inch Residential grade Controller Qty Description 1 Fire Pump System Pump Base mounted controller adapter: No Main Controller Fire pump controller CONTROLLER TO SHIP DIRECT Controller brand:All manufacturers lController voltage: 120 V Controller charger voltage: 12 V Controller frequency:50/60 Hz Direct Ship Controller:Yes Ship To Address: 1 lController type:Eaton FD140, 110/220V,5060hz Controller additional options Enclosure:-NEMA 2 Enclosure type: NEMA Type 2 Miscellaneous 1 Miscellaneous:-S1 Fuel Level Switch, 16 Inch Controller Language Options 1 Selected Language:English Jockey Pump Qty Description 1 Jockey pump,controller,and options Pump and motor Jockey pump supply:Grundfos CR Frequency:60 Hz Phase:Three Voltage:460 V Flow rate: Flow rated: 15 USgpm Total discharge head:Total discharge head:85.00 psi Direct Ship Jockey Pump:No 1 lJockey pump selected:CR 3-8-3ph/1.5Hp 56CFr Duty point: 14USgpm,85.3psi,Shutoff pressure: 108.2psi,460V,Oval flange, HQQE Seal type Jockey pump companion flange kit:None CAPITOL PUMP RESOURCES INC. •5891 Mullen Road SE Lacey,WA 98503 phone:360-493-1830• fax:360-923-1841 Page 2 of 5 �PEERLESS Peerless Express 24.6.5 Jockey • Controller Qty Description 1 Jockey pump,controller,and options Jockey pump controller JOCKEY PUMP CONTROLLER TO SHIP DIRECT Jockey pump controller required:Yes Manufacturer:Eaton Voltage:440-480 V Frequency:60 Hz Direct ship jockey pump controller:Yes Ship To Address: 1 Jockey pump controller selected: Eaton Controller XTJP,Jockey Touch-Across the Line, 1.50hp,440-480V,3Ph,60hz Jockey pump controller additional options Enclosure:-NEMA 2 Enclosure type:NEMA Type 2 Jockey Pump Controller Language Options 1 Selected Language: English Accessories Qty Description 1 Fire Pump System Driver Type Fuel tank Tank standard: UL 142 Wall type: Double wall 42 in Mounting legs:Yes 1 Fuel tank selected:UL Listed, Double wall 140gal 1 Leak sensor:Yes Fuel system 1 Fuel System Selected: Fuel system,Double Wall, Jockey pump,controller,and options Pump and motor Jockey pump casing relief valve:None selected Accessories Fire Pump Accessories 1 Air release valve:Air Release Valve,Val-Matic 0.5",300psi MWP, Listing: UL/FM 1 Gauge:-14lnHg/290psi Suction,0-600psi Discharge UL Listed Main relief system 1 Main relief valve:Valve,relief angle,Cla-Val,6"ANSI flange, 1501b ANSI, Pilot operated,20-200psi,250psi MWP, Listing: UL/FM 1 Overflow cone: Peerless 6"x 8", 1251b x 1251b Hose valve head 1 Hose valve head:8",Grooved, 1250-2000USgpm,400psi MWP,6 outlets,Cla-Val 6 Hose valve:Valve,hose angle,2.5"NPT internal thread, National standard,300psi MWP,Listing:UL/FM 1 Ball valve/drain:Valve,ball,0.5",600psi MWP Engineered Skid Package Qty Description 1 Skid Package Engineered Skid Package Engineered Packaged Skid: Not Required CAPITOL PUMP RESOURCES INC. •5891 Mullen Road SE Lacey,WA 98503 phone:360-493-1830• fax:360-923-1841 Page 3 of 5 �PEERLESS Peerless Express 24.6.5 Commercial Qty Description 1 Product Shipping Product Shipping 1 Shipping Container:Skid with bird cage Commercial Terms Commercial Terms Incoterms 2020: FCA Freight Included Named Place:Arlington,WA CAPITOL PUMP RESOURCES INC. •5891 Mullen Road SE Lacey,WA 98503 phone:360-493-1830• fax:360-923-1841 Page 4 of 5 �PEERLESS Peerless Express 24.6.5 Pump Performance Performance based on test acceptance-Hyd Inst 14.6 Unilateral(1 U) The rated point is the only guaranteed point(within the specified HI grade)on the performance curve. The published closed valve head has a+6%tolerance. Other specified duty points,including their tolerances,shall be per separate agreement between Peerless Pump Co.and buyer. 160 120 80 O 0- 40 0 150 135 14.00 in 44 60 71 78 120 83 105 11.83 in 011 82 '7n 90 O 75 f6 O = 60 10.00 in 45 30 15 0 0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 Flow- USgpm Customer :AFP Systems Inc. Peerless Model :6AEF14G Customer ref./PO Stages : 1 Tag Number :001 Speed,rated :2100 rpm Service Based on curve number :6AEF14G-2100 Rev FEB 2020 Quantity : 1 Efficiency :78.94% Quote Number/ID :25041880 Rated power(based on duty point) :94.1 hp Date last saved :31 Mar 2025 9:00 PM Max power(non-overloading) : 121.8 hp Flow,rated : 1,500 USgpm NPSH required Differential head/ :85.00 psi Viscosity : 1.00 cP pressure,rated Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00/1.00/1.00/1.00 Fluid density,rated/max : 1.000/1.000 SG Flow Head Efficiency Power NPSHr Thrust,total .. 0 93.35 0.00 45.5 - - 378 92.75 36.27 56.4 - - 756 91.49 58.61 68.9 - - 1,135 89.01 71.82 82.0 - - 1,513 84.75 79.11 94.5 - - 1,891 78.15 82.10 105.0 - - 2,269 68.64 80.83 112.4 - - 2,647 55.66 73.72 116.6 - - 3,025 38.66 57.63 118.4 - - 3,404 17.07 27.82 121.8 - - CAPITOL PUMP RESOURCES INC. •5891 Mullen Road SE Lacey,WA 98503 phone:360-493-1830• fax:360-923-1841 Page 5 of 5 CO® Worldwide www.tyco-fire.com Contacts Model ESFR-17 Early Suppression, Fast Response Pendent Sprinklers 16.8 K-factor General piping, as well as possibly reducing or eliminating the need for a system fire Description pump. =_ Applications for the ESFR-17 Pendent The TYCO Model ESFR-17 Pendent Sprinklers are expanding beyond cur- Sprinklers are Early Suppression, Fast rently recognized installation Stan- `. Response Sprinklers having a nominal dards. For information on research fire K-factor of 16.8. (Ref. Figure 1.) They tests, such as with flammable liquids i+ are suppression mode sprinklers that and aerosols, that may be accept- are especially advantageous as a able to an authority having jurisdic- means of eliminating in-rack sprinklers tion, contact the Technical Services when protecting high-piled storage. department. r. Model ESFR-17 Pendent Sprinklers are primarily used for ceiling-only sprinkler CAMI s protection of, but not limited to,the fol- The Model ESFR-17 Pendent Sprinklers lowing storage applications: described herein must be installed • Most encapsulated or non-encap- and maintained in compliance with sulated common materials including this document, as well as with the cartoned, unexpanded plastics applicable standards recognized by Technical the Approval agency, in addition to • Cartoned, expanded plastics the standards of any authorities having • Uncartoned, unexpanded plastics jurisdiction, such as FM Global. Failure Data to do so may impair the performance • Uncartoned, expanded plastics of these devices. Approvals • Some storage arrangements of The owner is responsible for main- FM Approved rubber tires, roll paper, and aerosols taining their fire protection system VdS Approved and devices in proper operating con- LPCB Approved(094b and 0071) For more specific criteria,refer to Table NYC under MEA 356-01-E A in this data sheet as well as the appli- dition. Contact the installing contrac- CE Certified Certificate of Conformity cable design standard. for or product manufacturer with any 1725-CPR-F0011 The Model ESFR-17 Pendent Sprin- questions. Finish klers provide the system designer In all cases, the appropriate NFPA or Natural Brass with hydraulic and sprinkler place- FM installation standard, or other appli- ment options not presently available cable standard, must be referenced Physical Characteristics to traditional ESFR Sprinklers having to ensure applicability and to obtain Frame .............................Brass complete installation guidelines. The Deflector..........................Bronze a nominal K-factor of 14.0. In particu- Compression Screw.......... Stainless Steel lar, Model ESFR-17 Pendent Sprinklers general guidelines in this data sheet Hook............................. Monel are designed to operate at substan- are not intended to provide complete Strut.............................. Monel tially lower-end head pressures, as i.nstallation criteria. Link Assembly................Solder,Nickel compared to ESFR Sprinklers having ■ Button.............................Brass a nominal K-factor of 14.0.This feature Sprinkler Sealing Assembly.......iu ......... InLCN Ejection Spring............... .. Inconel offers flexibility when sizing system Identification Deflector Nut........................Brass Additional Technical Data Number (SIN) Refer to Table A for additional techni- IMPORTANT cal data. Always refer to Technical Data Refer to Table A for sprinkler identifica- Sheet TFP700 for the "INSTALLER tion number. WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 MAY 2018 TFP315 TFP315 Page 2 of 4 1 7 3/4" NPT 1-1/2" Components: 8 1/2" (38,1 mm) 1 - Frame (12,7 mm) 2 - Deflector NOMINAL 3 Compression 9 MAKE-IN Screw 4 - Hook 6 5 Strut 3-9/16" THERMAL 6 Link Assembly II (90,5 mm) SENSING 7 Button 5 ELEMENT 8 - Sealing WRENCH Assembly 4 FLATS 9 - Ejection Spring 3 TEMPERATURE 2 RATING f1-7/8"(47,6 mm)---] FIGURE 1 MODEL ESFR-17 EARLY SUPPRESSION, FAST RESPONSE PENDENT SPRINKLER, 16.8 K-FACTOR Operation Item Description The fusible link assembly is com- Sprinkler Identification Number(SIN) TY7226 prised of two link halves that are joined together by a thin layer of solder.When K-factor,(gpm/psi'/=)(Ipm/bar'/2) 16.8 gpm/psi'/=(241,9 Ipm/bar'/2) the rated temperature is reached, the 165°F(74°C) solder melts and the two link halves Temperature Rating°F(°C) 214°F(101°C) separate, activating the sprinkler and flowing water. Thread Size 3/4 in.NPT or ISO 7-R 3/4 Sprinkler Orientation Pendent Maximum Working Pressure,psi(bar) 175 psi(12,1 bar) TABLE A MODEL ESFR-17 PENDENT SPRINKLER TECHNICAL DATA TFP315 Page 3of4 Design Storage Type FM Global Criteria The following general guidelines pro- vided for the TYCO Model ESFR-17 Sprinkler Type Storage Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- Response Type OR tion(NFPA)and FM Global(FM)provide installation standards that must be used to properly design an automatic System Type Wet sprinkler system utilizing Early Sup- pression, Fast Response(ESFR)Sprin- klers.The guidelines provided by NFPA and FM may differ; consequently, the Temperature Rating°F(°C) 2145 F(101°C) appropriate standard must be used for a given installation. Refer to Table B for Open Frame(i.e., no solid shelves)Single, additional information. Double, Multiple-Row,or Portable Rack Storage Refer to FM 2-0 and 8-9 In all cases, the appropriate NFPA or of Class I-IV and Group A or B Plastics FM installation standard must be ref- erenced to ensure applicability and to Solid Pile or Palletized Storage of Class I-IV and Refer to FM 2-0 and 8-9 obtain complete installation guidelines, Group A or B Plastics since the following general guidelines are not intended to provide complete Idle Pallet Storage Refer to FM 2-0,8-9,and 8-24 installation criteria. Refer to Table B for additional information. In addition to this data sheet, the fol- Rubber Tire Storage Refer to FM 2-0 and 8-3 lowing data sheets describe other TYCO ESFR Sprinklers: Roll Paper Storage Refer to FM 8-21 (Refer to the Standard) • TFP312 Model ESFR-25(TY9226) Flammable/Ignitable Liquid Storage Refer to FM 7-29 K=25.2 Pendent Sprinkler (Refer to the Standard) • TFP313 Aerosol Storage Model ESFR-22 (TY8226) (Refer to the Standard) Refer to FM 7-31 K=22.4 Pendnet Sprinkler • TFP316 Automotive Components in Portable Racks N/A Model ESFR-17(TY7126) (Control mode only;refer to the Standard) K=16.8 Upright Sprinkler N/A-Not Applicable • TFP317 TABLE B Model ESFR-17(TY7223) MODEL ESFR-17 PENDENT SPRINKLERS K=16.8 Pendent Sprinkler COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW • TFP318 Model ESFR-1 (TY6226) Where the depths of the solid structural Maximum Spacing K=14.0 Pendent Sprinkler members, such as beams and stem, 12 ft (3,7 m) for building heights • TFP319 exceed 12 in. (302 mm), install ESFR up to 30 ft(9,1 m) Model ESFR-14 (TY6236) Sprinklers in each channel formed by 10 ft(3,1 m)for building heights greater K=14.0 Pendent Sprinkler the structural members. than 30 ft(9,1 m) • TFP320 Ceiling Slope o Minimum Spacing Model ESFR-17(TY7229) Maximum 2 in.rise for 12 in.run(16.7/o) 8 ft(2,4 m) K=16.8 Pendent Sprinkler Maximum Coverage Area 100 ft2(9,3 m2) Minimum Clearance to Commodity Roof Construction 36 in. (914 mm) Unobstructed or obstructed construc- In some cases, the installation stan- Deflector-to-Ceiling Distance beam and girder. tion,such as smooth ceiling, bar joists, dards permit a greater coverage area. NFPA 6 in. to 14 in. (152 mm to Minimum Coverage Area 356 mm) 64 ft2(5,8 m2)per NFPA 13/FM 2-0 Centerline of Thermal Sensing Element-to-Ceiling Distance FM—See FM 2-0 for Storage Sprinklers. TFP315 Page 4of4 "FITTING SIDE" Care and Lir"ited TOWARDS SPRINKLER Maintenance Warranty 0� FITTING The TYCO Model ESFR-17 Sprinklers For warranty terms and conditions,visit must be maintained and serviced in www.tyco-fire.com. accordance with this section. I� Before closing a fire protection system Ordering main control valve for maintenance procedure WRENCH work on the fire protection system that RECESS it controls,permission to shut down the affected fire protection system must be Contact your local distributor for avail- FIGURE2 obtained from the proper authorities ability.When placing an order, indicate W-TYPE 21 and notify all personnel who may be the full product name and Part Number SPRINKLER WRENCH affected by this action. (P/N). Sprinklers which are found to be Sprinkler Assemblies Installation leaking or exhibiting visible signs of Specify: Model ESFR-17 (TY7226), corrosion must be replaced. K=16.8, Early Suppression, Fast Response Pendent Sprinkler with Automatic sprinklers must never be The TYCO Model ESFR-17 Pendent p (specify) temperature rating, natural Sprinklers must be installed in accor- painted, plated, coated, or other- brass, P/N (specify): dance with this section. wise altered after leaving the factory. Modified sprinklers must be replaced. 165°F(74°C)..................58-445-1-165 General Instructions Sprinklers that have been exposed to 214T(10VC).................58-445-1-214 Avoid damage to the fusible Link corrosive products of combustion, but Special Order Sprinkler Assembly during installation by using have not operated,should be replaced Assemblies with ISO 7-1 Thread only the Frame arms to handle the if they cannot be completely cleaned Connections sprinkler and by using the appropri- by wiping the sprinkler with a cloth or Specify: Model ESFR-17 (TY7226), ate sprinkler wrench. Do not apply by brushing it with a soft bristle brush. K=16.8, Early Suppression, Fast pressure to the fusible Link Assembly. Response Res Pendent Sprinkler with ISO Failure to do so can lead to an unstable Care must be exercised to avoid p p link assembly and premature activation damage to the sprinklers before, 7-1 thread connection, (specify) tem- of the sprinkler. Damaged sprinklers during, and after installation. Sprin- perature rating, natural brass, P/N must be replaced. klers damaged by dropping, striking, (specify): wrench twist/slippage,or the like, must 165°F(74°C)..................58-446-1-165 A leak-tight 3/4 in. NPT sprinkler joint be replaced.Also,replace any sprinkler 214°F(101°C).................58-446-1-214 should be obtained by applying a min- that has a cracked bulb or that has lost Sprinkler Wrench imum-to-maximum torque of 10 to 20 liquid from its bulb. Refer to Installation Specify: W-Type 21 Sprinkler Wrench, ft-lb (13,4 to 26,8 N•m). Higher levels section for additional information. of torque can distort the sprinkler inlet P/N 56-001-0-686 with consequent leakage or impairment The owner is responsible for the of the sprinkler. inspection,testing,and maintenance of their fire protection system and devices Step 1. Install the Model ESFR-17 in compliance with this document, as Pendent Sprinkler in the pendent posi- well as with the applicable standards tion (Ref. Figure 2). of the National Fire Protection Associ- Step 2. With pipe-thread sealant ation, such as NFPA 25, in addition to applied, hand-tighten the sprinkler into the standards of any authorities having the sprinkler fitting. Do not apply pres- jurisdiction.Contact the installing con- sure to the Link Assembly, and handle tractor or product manufacturer with the Model ESFR-17 Sprinkler only by any questions. the Frame arms. Automatic sprinkler systems are rec- Step 3. Wrench-tighten the Model ommended to be inspected, tested, ESFR-17 Sprinkler using only the and maintained by a qualified Inspec- W-Type 21 Sprinkler Wrench (Ref. tion Service in accordance with local Figure 2)and by fully engaging(seating) requirements and/or national codes. the wrench on the sprinkler wrench flats(Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-17 Sprinkler for damage. In particular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assembly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a registered trademark of DuPont CO® Worldwide www.tyco-fire.com Contacts Series TY.FRB - 2.89 4.2, 5.6, and 9.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage to corrosive atmospheres. Although General corrosion-resistant coated sprinklers Description have passed the standard corrosion tests of the applicable approval agen- The TYCO Series TY-FRB 2.8,4.2,5.6, cies, the testing is not representativell of all possible corrosive atmospheres. and 8.0 K-factor Upright, Pendent, Consequently, it is recommended that ' and Recessed Pendent Sprinklers the end user be consulted with respect WMi described in herein are quick response,standard coverage, decorative 3 mm to the suitability of these coatings for glass bulb-type spray sprinklers.They any given corrosive environment. The are designed for use in light or ordinary effects of ambient temperature, con- hazard,commercial occupancies such chemical to chemicals, and gas/ as banks, hotels, and shopping malls. chemical velocity, should it the cconso- ered,as a minimum,along with the cor- I� The TY-FRB Recessed Pendent Sprin- rosive nature of the chemical to which I kler, where applicable, is intended for the sprinklers will be exposed. use in areas with a finished ceiling.This An intermediate level version of the recessed pendent sprinkler uses one of i the following Recessed Escutcheons: Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet 1 • A two-piece Style 10 (1/2 in. NPT) TFP356. Sprinkler Guards are detailed or Style 40 (3/4 in. NPT) Recessed in Technical Data Sheet TFP780. -� } Escutcheon with 1/2 in.(12,7 mm)of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from The Series TY--FRB 2.8, 4.2, 5.6,the flush pendent position. and 8.0 K-factor Upright, Pendent, Sprinkler • A two-piece Style 20 (1/2 in. NPT) and Recessed Pendent Sprinklers 0 or Style 30 (3/4 in. NPT) Recessed described herein must be installed Identification Escutcheon with 1/4 in. (6,4 mm) of and maintained in compliance with recessed adjustment or up to 1/2 in. this document and with the applicable Number (S I M (12,7 mm) of total adjustment from standards of the National Fire Protec- the flush pendent position. tion Association (NFPA), in addition to TY1131 . . .Upright 2.8K, 1/2 in. NPT The adjustment provided by the the standards of any authorities having TY1231 . . Pendent 2.8K, 1/2 in. NPT Recessed Escutcheon reduces the jurisdiction. Failure to do so may impair TY2131 . . .Upright 4.2K, 1/2 in. NPT accuracy to which the fixed pipe drops the performance of these devices. TY2231 . . Pendent 4.2K, 1/2 in. NPT to the sprinklers must be cut. The owner is responsible for maintain- TY3131 . . . Upright 5.6K, 1/2 in. NPT Corrosion-resistant coatings, where ing their fire protection system and TY3231 . . Pendent 5.6K, 1/2 in. NPT applicable, are utilized to extend the devices in proper operating condition. TY4131 . . .Upright 8.OK, 3/4 in. NPT life of copper alloy sprinklers beyond The installing contractor or sprinkler TY4231 . . Pendent 8.OK, 3/4 in. NPT what would be obtained when exposed manufacturer should be contacted with any questions. TY4831 . . . Upright 8.OK, 1/2 in. NPT IMPORTANT NFPA 13 prohibits installation of 112 in. TY4931 . . Pendent 8.OK, 1/2 in. NPT Refer to Technical Data Sheet NPT sprinklers with K-factors greater Technical TFP2300 for warnings pertaining to than 5.6 in new construction. They are regulatory and health information. intended for retrofit in existing sprinkler Data systems only. Always refer to Technical Data Approvals Sheet TFP700 for the "INSTALLER UL and C-UL Listed WARNING" that provides cautions FM,LPCB,and NYC Approved with respect to handling and instal- lation of sprinkler systems and com- Refer to Table A and B for complete approval onents. Improper handlin and information including corrosion-resistant pg status. installation can permanently damage a sprinkler system or its compo- Maximum Working Pressure nents and cause the sprinkler to fail Refer to Table C to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 JULY 2018 TFP171 TFP171 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 Deflector* SURFACE 7 Bushing 7 1 7/16" (11,1 mm) --3 NOMINAL 2-1/4" MAKE-IN (57,2 mm) 2 1 2-3/16" 4 (55,6 mm) 1 -- (39,7 mm) 5 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 IN. NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 7/16" 3 7(l 11,1 mm) 2 NOMINAL 2-3/16" MAKE-IN (55,6 mm) 2-3/16" 1-1/2 4 " (55,6 mm) (38,1 mm) _5 ! 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 IN. NPT Discharge Coefficient Poly-Stainless pes i g n K=2.8 GPM/psi'/=(40,3 LPM/bars) Physical Characteristics K=4.2 GPM/psi'/(60,5 LPM/bar!) Frame ............................Bronze Criteria K=5.6 GPM/psi/(80,6 LPM/bar'i) Button................ L316 Stainless Steel* K=8.0 GPM/psi!(115,2 LPM/bar'/) Bulb...............................Glass Compression Screw..... L316 Stainless Steel" The TYCO Series TY-FRB 2.8,4.2,5.6, Temperature Rating Deflector...................Copper/Bronze and 8.0 K-factor Upright, Pendent, Refer to Table A and B Sealing Assembly.Gold Plated Beryllium Nickel and Recessed Pendent Sprinklers are w/TEFLON Finishes 'Type L316 stainless steel(UNS 31603)per ASTM intended for fire protection systems Sprinkler: Refer to Table D A479/479M or Bs EN 1008 wN1.4404. designed in accordance with the Stan- Recessed ■ dard installation rules recognized by GreyAluminu ,Jet Blak,Signal Chrome aced, Operation the applicable Listing or Approval Grey Aluminum,Jet Black,Chrome Plated, or Natural Brass agency, such as UL Listing based on The glass bulb contains a fluid that the requirements of NFPA 13 and FM Physical Characteristics expands when exposed to heat.When Approval based on the requirements Frame ............................Bronze the rated temperature is reached, the of the FM Global Loss Prevention Data Butto g Assembly...Beryllium ...NicBrlass/Coppew/TEFLO fluid expands sufficiently to shatter the Sheets. Use only the style 10,20,30,or SealBulb...............................Glass glass bulb, allowing the sprinkler to 40 Recessed Escutcheon, as applica- Compression Screw.................Bronze activate and water to flow. ble,for recessed pendent installations. Deflector...................Copper/Bronze Bushing(K=2.8) ....................Bronze TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 7/16" 3 (11,1 mm) NOMINA MAKE-NL 2-3/16" 2 (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) f 5 IL / 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm)DIA. — FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ -- — SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 7/16" _—_= 3 1,1 mm) MAKE-INNOMINA 2-3/16" 2 J(1(N 2 (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1�mm) 5 1 — 6* STYLE 10 2-7/8"(73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT of the sprinkler. Do not attempt to com- Series TY-FRB Recessed Pendent Installation pensate for insufficient adjustment in Sprinklers The TYCO Series TY-FRB 2.8,4.2,5.6, the escutcheon plate by under-or over- The Series TY-FRB Recessed Pendent and 8.0 K-factor Upright, Pendent,and tightening the sprinkler. Re-adjust the Sprinklers must be installed in accor- Recessed Pendent Sprinklers must position of the sprinkler fitting to suit. dance with the following instructions: be installed in accordance with this Series TY-FRB Upright and Pendent Step 1.After installing the Style 10,20, section. Sprinklers 30, or 40 Mounting Plate, as applica- General Instructions The Series TY-FRB Upright and ble,over the sprinkler threads and with Do not install any bulb type sprinkler Pendent Sprinklers must be installed pipe-thread sealant applied to the pipe if the bulb is cracked or there is a loss in accordance with the following threads, hand-tighten the sprinkler into of liquid from the bulb. With the sprin- instructions: the sprinkler fitting. kler held horizontally,a small air bubble Step 1.Install pendent sprinklers in the Step 2. Tighten the sprinkler into the should be present.The diameter of the pendent position. Install upright sprin- sprinkler fitting using only the W-Type air bubble is approximately 1/16 in. klers in the upright position. 7 Recessed Sprinkler Wrench (Ref. (1,6 mm) for the 135°F (57°C) and Step 2. With pipe thread sealant Figure 15).With reference to Figure 1 to 3/32 in. (2,4 mm)for the 286°F(141°C) applied to the pipe threads, hand- 4,apply the W-Type 7 Recessed Sprin- temperature ratings.A leak-tight 1/2 in. tighten the sprinkler into the sprinkler kler Wrench to the sprinkler wrench NPT sprinkler joint should be obtained fitti flats. fitting.by applying a minimum-to-maximum Step 3. After the ceiling is installed or torque of 7 to 14 lb-ft(9,5 to 19,0 N•m). Step 3. Tighten the sprinkler into the the finish coat is applied, slide on the A leak tight 3/4 in. NPT sprinkler joint sprinkler fitting using only the W-Type 6 Style 10, 20, 30, or 40 Closure over should be obtained with a torque of Sprinkler Wrench(Ref. Figure 14).With the Series TY-FRB Recessed Pendent 10 to 20 lb-ft(13,4 to 26,8 N•m). Higher reference to Figure 1 to Figure 5,apply Sprinkler and push the Closure over the levels of torque can distort the sprinkler the W-Type 6 Sprinkler Wrench to the Mounting Plate until its flange comes in inlet and cause leakage or impairment sprinkler wrench flats. contact with the ceiling. TFP171 Page 4 of 10 *Temperature rating ** Pipe thread connections per 1 Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" 3 (12,7 mm) NOMINAL T(5 5/16" 2 MAKE-IN 7 mm) 2-1/4" 1-9/16" 4 (57,2 mm) (39,7 mm) 5 6* 3/4" NPT** WRENCH STYLE 30 or 40 FLATS RECESSED 2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 1/2" 3 (12,7 mm) NOMINAL 2 MAKE-IN 2-5/16" (58,7 mm) 4 1-9/16" (57,2 mm) (39,7 mm) 5 6* STYLE 40 2-7/8"(73,0 mm)DIA. — RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,314 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 Deflector Assembly 3 4 - Bulb 7/16 2-1/4" (11,1 mm) (57,2 mm) 2 NOMINAL MAKE-IN * Temperature rating is 2-3/16" 1-9/16" 4 indicated on Deflector. (55,6 mm) i (39,7 mm) ii�5 ** Pipe thread connections \ per ISO 7-1 can be 6 * provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFP171 Page 5 of 10 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) 7 FACE OF mm MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" -rrl � (3,2 mm) ► (3,2 mm) 1 T PTi'. 7 ' MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 IN. NPT 2.8 K-FACTOR, 112 IN.NPT 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/41/4"(6 mm)mm4 (17 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER MOUNTING SPRINKLER PLATE PLATE FITTING FITTING 1/8" (3,2 mm) ► (3,2 mm) ► � Pr T. 2 MOUNTING MOUNTING SURFACE SURFACE 7 CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 IN. NPT 4.2 K-FACTOR, 112 IN.NPT TFP171 Page 6 of 10 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE (SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) 1 � PT r � 1 i MOUNTING ' MOUNTING SURFACE SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN.NPT 5.6 K-FACTOR, 112 IN. NPT 2-7/8"DIA. 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE ( SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 IN. NPT 8.0 K-FACTOR, 314 IN. NPT WRENCH RECESS / WRENCH RECESS (END"A" USED FOR 1/2" NPT MODELS) WRENCH RECESS PUSH WRENCH (END"B" USED FOR IN TO ENSURE 3/4" NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 10 Sprinkler Finish5 K- Bulb Liquid Natural Factor Type Temperature Color Brass Chrome Plated Polyester 135°F(57°C) Orange Pendent 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 Upright 200°F(93°C) Green (TY1131) 286°F(141°C) Blue 135°F(57°C) Orange 2.8 Recessed 68 155°F °C Red 1/2 in.NPT Pendent ( ) (TY1231)a 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 1,2,4 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)b 175°F(79°C) Yellow Figure 7 200°F(93°C) Green 135°F(57°C) Orange Pendent 155°F(68°C) Red (TY2231) and 175°F(79°C) Yellow Upright(TY2131) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 Recessed 68 155°F °C Red 1,2 1/2 in.NPT Pendent ( ) (TY2231)a 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)b 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 8 of 10 Sprinkler Finishs K- Bulb Liquid Natural Chrome Lead Factor Type Temperature Color Brass Plated Polyesters Poly-Stainless Coated 135°F(57°C) Orange Pendent(TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,3,5 (TY3 ri 31) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 5.6 Recessed 155°F(68°C) Red 1/2 in. Pendent 175°F(79°C) Yellow 1,2,4,5 1,2 N/Ad NPT (TY3231)a Fiigure 10 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent(TY3231)6 ° °175 F 79 C Yellow 1,2,3,4,5 N/A N/A Figure 11 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Pendent(TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,5 Upright 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 80 Recessed 155°F(68°C) Red 3/4 in. (TY4231)a Pendent 175°F(79°C) Yellow 1,2,5 1,2 N/A NPT Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent(TY4231)6 ° °175 F 79 C Yellow 1,2,3,5 N/A N/A Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Pendent 8.0 (TY4931) 155°F(68°C) Red 1/2 in. and 175°F(79°C) Yellow 1,2,4,5,6 N/A 1,2,5 NPT Upright 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not Available(N/A) 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 9 of 10 Sprinkler Finish K- Type Natural Chrome polyester Lead Coated Factor Brass Plated Pendent(TY1231) and 2.8 Upright(TY1131) 1/2 in. 175 psi(12,1 bar) N/A2 NPT Recessed Pendent(TY1231) Pendent(TY2231) and 4.2 Upright(TY2131) 1/2 in. 175 psi(12,1 bar) N/A NPT Recessed Pendent(TY2231) Pendent(TY3231) and 5.6 Upright(TY3131) 250 psi(17,2 bar) 1/2 in. or 175 psi(12,1 bar)' NPT Recessed Pendent(TY3231) Pendent(TY4231) 175 psi and (12,1 bar) 8.0 Upright(TY4131) 3/4 in. 175 psi(12,1 bar) NPT Recessed Pendent(TY4231) N/A 8.0 Pendent(TY4931) 175 psi 1/2 in. and 175 psi(12,1 bar) (12,1 bar) NPT Upright(TY4831) NOTES 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. 2. Not applicable(N/A). TABLE C MAXIMUM WORKING PRESSURE Care and corrosive products of combustion, but requirements and/or national codes. have not operated,should be replaced Care must be exercised to avoid Maintenance if they cannot be completely cleaned damage to the sprinklers before, by wiping the sprinkler with a cloth or during, and after installation. Sprin- The TYCO Series TY-FRB 2.8,4.2,5.6, by brushing it with a soft bristle brush. klers damaged by dropping, striking, and 8.0 K-factor Upright, Pendent,and Care must be taken to avoid damage wrench twist/slippage,or the like,must Recessed Pendent Sprinklers must be to the sprinklers before, during, and be replaced. Also, replace any sprin- maintained and serviced in accordance after installation. Sprinklers damaged kler that has a cracked bulb or that has with this section. Before closing a fire by dropping, striking, wrench twist/ lost liquid from its bulb. (Ref. Installa- protection system main control valve slippage,or the like, must be replaced. tion Section). for maintenance work on the fire pro- Also, replace any sprinkler that has a Initial and frequent visual inspections of tection system that it controls, obtain cracked bulb or that has lost liquid from random samples are recommended for permission to shut down the affected its bulb. (Ref. Installation Section). corrosion-resistant sprinklers to verify fire protection systems from the proper The owner is responsible for the the integrity of the corrosion-resistant authorities and notify all personnel who inspection,testing,and maintenance of material of construction. Thereafter, may be affected by this action. their fire protection system and devices annual inspections per NFPA 25 should Absence of the outer piece of an in compliance with this document, as suffice.lnspections of corrosion-resis- escutcheon, which is used to cover well as with the applicable standards tant sprinklers are recommended at a clearance hole, can delay sprinkler of the National Fire Protection Asso- close range, instead of from the floor operation in a fire situation. ciation (e.g., NFPA 25), in addition to level per NFPA. Inspection at close Sprinklers which are found to be the standards of any other authorities range can better determine the exact leaking or exhibiting visible signs of having jurisdiction.Contact the install- sprinkler condition and the long-term corrosion must be replaced. ing contractor or sprinkler manufac- integrity of the corrosion-resistant turer regarding any questions. material, which can be affected by the Automatic sprinklers must never be Automatic sprinkler systems are rec- corrosive conditions present. painted, plated, coated, or other- ommended to be inspected, tested, wise altered after leaving the factory. and maintained by a qualified Inspec- Modified sprinklers must be replaced. tion Service in accordance with local Sprinklers that have been exposed to TFP171 Page 10 of 10 P/N 57 — XXX — X — XXX SIN TEMPERATURE SPRINKLER RATINGS FINISH 330 2.8K UPRIGHT(1/2 in. NPT) TY1131 135 135°F(57°C) 1 NATURAL BRASS 331 2.8K PENDENT(1/2 in.NPT) TY1231 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 340 4.2K UPRIGHT(1/2 in. NPT) TY2131 POLYESTER 175 175°F(79°C) PURE WHITE 341 4.2K PENDENT(1/2 in.NPT) TY2231 3 POLYESTER(RAL9010)2 200 200eF(93°C) SIGNAL WHITE 370 5.6K UPRIGHT(1/2 in. NPT) TY3131 4 POLYESTER(RAL9003) 286 286°F(141°C) JET BLACK 371 5.6K PENDENT(112 in.NPT) TY3231 5 POLYESTER(RAL9005)3 390 8.OK UPRIGHT(3/4 in.NPT) TY4131 7 LEAD COATED 391 8.OK PENDENT(3/4 in. NPT) TY4231 9 CHROME PLATED 360 8.OK UPRIGHT(1/2 in. NPT) TY4831 NOTES 1. Available only on TY3131,TY3231,TY4131,and TY4231 2. Eastern Hemisphere sales only. 361 8.OK PENDENT(1/2 In. NPT) TY4931 3. Available in only 2.81K,4.21K,and 8.OK,155°F(68°C)and 200°F(93°C);requires longer lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify") finish, P/N (specify) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Contro�S TEFLON Is a registered trademark of DuPont CO® Worldwide www.tyco-fire.com Contacts Series TY-6 - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage IMPORTANT The TY-B Recessed Pendent Sprinkler, -�- Refer to Technical Data Sheet where applicable, is intended for use in areas with a finished ceiling. It uses a TFP2300 for warnings pertaining to two-piece Style 10(1/2 in.NPT)or Style $ ; regulatory and health information. 40(3/4 in. NPT)Recessed Escutcheon. Always refer to Technical Data The Recessed Escutcheon provides { Sheet TFP700 for the "INSTALLER 1/2 in. (12,7 mm) of recessed adjust- WARNING" that provides cautions ment or up to 3/4 in. (19,1 mm) of total with respect to handling and instal- adjustment from the flush pendent lation of sprinkler systems and com- position. The adjustment provided by ponents. Improper handling and the Recessed Escutcheon reduces the installation can permanently damage accuracy to which the fixed pipe drops a sprinkler system or its compo- to the sprinklers must be cut. nents and cause the sprinkler to fail Corrosion-resistant coatings, where to operate in a fire situation or cause applicable, are utilized to extend it to operate prematurely. the life of copper alloy sprinklers beyond what would be obtained Scan the OR code or enter the URL when exposed to corrosive atmo- in a web browser to access the most spheres. Although corrosion-resistant up-to-date electronic version of this coated sprinklers have passed the document. Data rates ma a I standard corrosion tests of the appli- y pp y' cable approval agencies, the testing is not representative of all possible corrosive atmospheres.Consequently, ■ it is recommended that the end-user be The owner is responsible for maintain- consulted about the suitability of these ing their fire protection system and J coatings for any given corrosive envi- devices in proper operating condi- �■ ronment. The effects of ambient tem- tion. Contract the installing contrac- ■ perature, concentration of chemicals, for or product manufacturer with any and gas/chemical velocity, should be questions. considered as a minimum, along with NFPA 13 prohibits installation of 112 in. the corrosive nature of the chemical to NPT sprinklers with K-factors greater ■ which the sprinklers will be exposed. than 5.6 in new construction. They are • An intermediate level version of the intended for retrofit in existing sprinkler ■ Series TY-B Pendent Sprinkler can be systems only. docs.jci.com/tycofire/tfp151 obtained by utilizing the Series TY-B Sprinkler Pendent Sprinkler in combination with the Model S2 Shield. General Identification The Series 2.8,5.6,and 8.0 K-fac- Numbers (SIN) Description The TYCO Series TY-B 2.8, 5.6, tor, Upright, Pendent, and Recessed TY1151 . . . Upright 2.8K, 1/2 in. NPT and 8.0 K-factor, Upright, Pendent, Pendent Sprinklers described herein TY1251 . . .Pendent 2.81K, 1/2 in. NPT and Recessed Pendent S rin- must be installed and maintained in p compliance with this document,as well TY3151 . . . Upright 5.6K, 1/2 in. NPT klers described herein are standard TY3251 . . .Pendent 5.6K, 1/2 in. NPT response, standard coverage,decora- as with the applicable standards of the tive 5 mm glass bulb-type spray sprin- National Fire Protection Association TY4151 . . . Upright 8.01K, 3/4 in. NPT klers.They are designed for use in light, (NFPA), in addition to the standards of TY4251 . . .Pendent 8.01K, 3/4 in. NPT ordinary, or extra-hazard commercial any other authorities having jurisdiction. TY4851 . . . Upright 8.01K, 1/2 in. NPT occupancies such as banks, hotels, Failure to do so may impair the perfor- TY4951 . . .Pendent 8.01K, 1/2 in. NPT shopping malls, factories, refineries, mance of these devices. and chemical plants. Page 1 of 8 JANUARY 2024 TFP151 TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw _ 7 3 Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 - Bulb 7/16 7 2-1/4" (11,1 mm) 3 (57,2 mm) NOMINAL MAKE-IN 2 *Temperature rating is 7� 12-3/16" 1-9/16" indicated on Deflector. (55,6 mm) 1 (39,7 mm) 4 5 ** Pipe thread connections \ per ISO 7-1 can be 6* provided on special 1/2"NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 'ffN 7/16" 3 (11,1 mm) NOMINAMAKEOMII-NL L/2" 6" Eir mm) 2-3/16" 4 (55,6 mm) ( L 5 6* 1/2" NPT** WRENCH STYLE 10 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" E912 3 (12,7 mm) N — NOMINAL T21/16" 2 MAKE A mm) 2-1/4" 1-9/16 4 (57,2 mm) (39,7 mm) —5 _6* 3/4" NPT** WRENCH STYLE 40 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,314 IN.NPT, STANDARD RESPONSE TFP151 Page 3of8 CEILING PLATE 1 - Frame 5 Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 Deflector* Assembly 3 4 - Bulb (11,1 mm) 57,2 mm NOMINAL ( ) 2 MAKE-IN *Temperature rating is 2-3/16" 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) 1 --- --- 5 ** Pipe thread connections \ 'I per ISO 7-1 can be -6* provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4 (73,0 mm) 3/4"(19,1 mm) 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) " (15,9 6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) 57,2 mm � (57,2 mm) FACE OF ( ) MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE I SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-B 3/4"(19,1 mm) TY B 13/16"(20,6 mm) FIGURE 5 FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 IN. TOTAL ASSEMBLY WITH TWO-PIECE 314 IN. TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN. NPT 8.0 K-FACTOR,314 IN. NPT Technical Finishes Design Sprinkler:See Table E Data Recessed Escutcheon:Signal or Pure White, Criteria Grey Aluminum,Jet Black,Chrome Plated, Approvals or Natural Brass The TYCO Series TY-B 2.8, 5.6, and UL and C-UL Listed Physical Characteristics 8.0 K-factor, Upright, Pendent, and FM,LPCB,and VdS Approved Frame ............................Bronze Recessed Pendent Sprinklers are EAC Approved Button......................Brass/Copper intended for fire protection systems Sealing Assembly..Beryllium Nickel w/TEFLON designed in accordance with the Stan- Note: For complete approval infor- Bulb............... ...Glass mation, including corrosion-resistant Compression Screw.................Bronze dard installation rules recognized by status, see Tables A, B, and C. Deflector......................... Copper the applicable Listing or Approval Bushing(K=2.8).....................Bronze agency, such as UL Listing based on Maximum Working Pressure the requirements of NFPA 13 and FM See Table D Operation Approval based on the requirements Discharge Coefficient of the FM Global Loss Prevention Data K=2.8 gpm/psi'/2(40,3 Lpm/bar'/2) The glass bulb contains a fluid which Sheets. Use only the Style 10 or 40 K=5.6 gpm/psi' (80,6 Lpm/bar!) expands when exposed to heat.When Recessed Escutcheon, as applicable, K=8.0 gpm/psi/2(115,2 Lpm/bars) the rated temperature is reached, the for recessed pendent installations. Temperature Ratings fluid expands sufficiently to shatter the See Tables A,B and C glass bulb, allowing the sprinkler to activate and water to flow. TFP151 Page 4of8 Do not attempt to compensate for The steel rod should be heated only to insufficient adjustment in the escutch- the point it can begin to melt the wax, / eon plate by under- or over-tightening and appropriate precautions need to be WRENCH RECESS the sprinkler. Readjust the position of taken when handling the heated rod in (END"A" USED FOR the sprinkler fitting to suit. order to prevent the installer from being 1/2" NPT MODELS) Series TY-B Upright and Pendent burned. Sprinklers Installation Series TY-B Recessed Pendent The Series TY-B Upright and Pendent Sprinklers Sprinklers must be installed in accor- The Series TY-B Recessed Pendent WRENCH RECESS dance with the following instructions: Sprinklers must be installed in accor- (END"B" USED FOR dance with the following instructions: 3/4" NPT MODELS) Step 1.Install pendent sprinklers in the pendent position. Install upright sprin- Step 1. After installing the Style 10 FIGURE 7 TYPE 7 klers in the upright position. or 40 Mounting Plate, as applicable, over the sprinkler threads and with SPRINKLER WRENCH Step 2. With pipe thread sealant pipe thread sealant applied to the pipe applied to the pipe threads, hand- threads, hand-tighten the sprinkler into tighten the sprinkler into the sprinkler the sprinkler fitting. WRENCH fitting. RECESS Step 3. Tighten the sprinkler into the Step 2. Tighten the sprinkler into the sprinkler p 3. fitting the only the W-T e sprinkler fitting using only the W-Type 7 p g g y yp Recessed Sprinkler Wrench,see Figure 6 Sprinkler Wrench, see Figure 7. 8.With reference to Figure 3 or 4,apply For wax-coated sprinklers, use an the W-Type 7 Recessed Sprinkler 8 or 10 in. adjustable wrench. With wrench to the sprinkler wrench flats. reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench Step 3.After the ceiling is installed or or an adjustable wrench,as applicable, the finish coat is applied, slide on the to the sprinkler wrench flats. Style 10 or 40 Closure over the Series PUSH WRENCH TY-B Recessed Pendent Sprinkler INTO ENSURE Wax Coated Sprinklers and push the Closure over the Mount- ENGAGEMENT When installing wax-coated sprinklers ing Plate until its flange contacts the WITH SPRINKLER with an adjustable wrench,take care to ceiling. WRENCHING AREA prevent damage to the wax coating on the sprinkler wrench flats or frame arms Care and FIGURE 8 and, consequently, exposure of bare W-TYPE 7 RECESSED metal to the corrosive environment: Maintenance SPRINKLER WRENCH • Open the jaws of the wrench suffi- ciently wide to pass over the wrench The TYCO Series TY-B 2.8, 5.6, and Installation flats without damaging the wax 8.0 K-factor, Upright, Pendent, and coating. Recessed Pendent Sprinklers must be The TYCO Series TY-B 2.8, 5.6, and • Before wrench tightening the sprin- maintained and serviced in accordance 8.0 K-factor, Upright, Pendent, and kler, adjust the jaws of the wrench with this section. Recessed Pendent Sprinklers must to contact only the sprinkler wrench Before closing a fire protection system be installed in accordance with this flats. main control valve for maintenance section. • After wrench tightening the sprin- work on the fire protection system General Instructions kler, loosen the wrench jaws before that it controls, obtain permission to Do not install any bulb type sprinkler removing the wrench. shut down the affected fire protection if the bulb is cracked or there is a loss After Installation system from the proper authorities of liquid from the bulb. With the sprin- After installation, complete the and notify all personnel who may be kler held horizontally,a small air bubble following: affected by this action. should be present.The diameter of the Inspect the sprinkler wrench flats The owner must assure that the sprin- air bubble is approximately 1/16 in. and frame arms and retouch (repair) klers are not used for hanging any (1,6 mm) for the 135°F (57°C) to the wax coating whenever the coat- objects and that the sprinklers are only 3/32 in. (2,4 mm)for the 360oF(182°C) ing has been damaged and bare cleaned by means of gently dusting temperature ratings. metal is exposed. with a feather duster; otherwise, non- A leak-tight 1/2 in. NPT sprinkler Retouch the wax coating on the operation in the event of a fire or inad- oint should be obtained b apply- wrench flats b gently applying a vertent operation may result. 1 Y Pp Y- Y 9 Y ing a minimum-to-maximum torque of heated 1/8 in. diameter steel rod Absence of an escutcheon, which is 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain to the damaged areas of wax, to used to cover a clearance, may delay a leak-tight 3/4 in. NPT sprinkler joint smooth it back over areas where the time to sprinkler operation in a fire by applying a minimum to maximum bare metal is exposed. situation. torque of 10 to 20 lb-ft (13,4 to Sprinklers which are found to be 26,8 N•m). Higher levels of torque may leaking or exhibiting visible signs of distort the sprinkler inlet and cause Only retouching of the wax coating corrosion must be replaced. leakage or impairment of the sprinkler. applied to the wrench flats and frame arms is permitted, and the retouching Automatic sprinklers must never be is to be performed only at the time of painted, plated, coated, or other- the initial sprinkler installation. wise altered after leaving the factory. Modified sprinklers must be replaced. TFP151 Page 5of8 Bulb Sprinkler Firl K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyesters Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange Upright 155°F(68°C) Red (TY1151) 2.8 and 175°F(79°C) Yellow 1,2,3 Pendent d 1/2 in. N/A NPT (TY1251) 200°F(93°C) Green d Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Recessed Escutcheon,as applicable 3. Approved by FM Global(FM Approvals) b. 150°F(66°C)maximum ceiling temperature 4. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated c. Frame and deflector only Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL d. Not Applicable(N/A) Listed as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM ADoroved as Corrosion-Resistant Sprinklers TABLE A SERIES TY-B 2.8 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS Bulb Sprinkler Finish5 K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyester Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange N/Ad N/Ad 155°F(68°C) Red 1,2,3,4 1,2,3,4 Upright 175°F(79°C) Yellow N/Ad 1,2,3,4 (TY3151) 1,2,3,4 1,2,3,4 1,2,3,4 Figure 2 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4 1b,2b,31b,4b 11b,2b,3b,4b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange N/Ad 5.6 155°F(68°C) Red 1,2,3,4 1/2 in. Pendent 175°F(79°C) Yellow 1,2,3,4 NPT (TY3251) 1,2,3,4 1,2,3,4,5 Figure 2 200°F(93°C) Green 286°F(141°6) Blue 1b,2b,31b,4b 11b,2b,3b,4b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1,2,3,4 (TY3251)a 175°F(79°C) Yellow N/Ad Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2,4 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Recessed Escutcheon,as applicable 3. Approved by FM Global(FM Approvals) b. 150°F(66°C)maximum ceiling temperature 4. EAC Approved c. Frame and deflector only 5. Where Polyester Coated, Lead Coated,Wax Coated, and Wax-over-Lead Coated d. Not Applicable(N/A) Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over- Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers TABLE B SERIES TY-B 5.6 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 6 of 8 Bulb Sprinkler Firl K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyesters Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1,2,3,8 1,2,8 (TY4151) 1,2,3,4,6,7,8 1,2,5,8 Figure 3 200°F(93°C) Green 286°F(141°C) Blue 1b,2b,3b,8b 1b,2b,3b,8b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange 1,2,3,4,6,7,8 1,2,3,8 8.0 155°F(68°C) Red 3/4 in. Pendent 175°F(79°C) Yellow 1,2,4,6,7,8 1,2,8 1,2,8 NPT (TY4251) 1,2,5,8 Figure 3 200°F(93°C) Green 1,2,3,8 286°F(141°C) Blue 1,2,3,4,6,7,8 1b,2b,3b,8b 1b,2b,3b,8b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange 1,2,3,4,8 Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,4,8 N/Ad (TY4251)a Figure 6 200oF(93'C) Green 1,2,3,4,8 286°F(141°C) Blue 1,2,8 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1 2 3 1, , 3, (TY4851)) 4 6 4,6 1,4,� N/Ad Figure 4 200°F(93°C) Green 286°F(141°C) Blue 8.0 360°F(182°C) Mauve N/Ad 1/2 in. NPT 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4951) 1,2,3,4,6 N/Ad Figure 4 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 9. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed 3. Approved by FM Global(FM Approvals) as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over- 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved 5. Note not used as Corrosion-Resistant Sprinklers 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands, a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Tel.31-53-428-4444/Fax 31-53-428-3377) Recessed Escutcheon,as applicable 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) b. 150°F(66°C)maximum ceiling temperature 8. EAC Approved c. Frame and deflector only d. Not Applicable(N/A) TABLE C SERIES TY-B 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 7 of 8 Sprinkler Finish K-Factor Type Natural Chrome Lead Wax Wax-Over-Lead Brass Plated Polyesters Coated Coated Coated 2.8 Upright(TY1151)and 175 psi(12,1 bar) N/A3 1/2 in. NPT Pendent(TY1251) Upright(TY3151)and 5.6 Pendent(TY3251) 250 psi(17,2 bar)2 1/2 in. NPT or Recessed Pendent 175 psi(12,1 bar) (TY3251) Upright(TY4151)and 175 psi(12,1 bar) 8.0 Pendent(TY4251) 3/4 in.NPT Recessed Pendent (TY4251) 175 psi(12,1 bar) N/A3 8.0 Upright(TY4851)and 175 psi(12,1 bar) 1/2 in. NPT Pendent(TY4951) NOTES 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL)and the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Not Applicable(N/A) TABLE D SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATING 530 2.8K UPRIGHT(1/2 in.NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2 in.NPT) TY1251 3 PURE WHITE(RAL9010)l 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2 in.NPT) TY3151 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2 in.NPT) TY3251 5 JET BLACK(RAL9005)2 200 200°F(93°C) POLYESTER 590 8.OK UPRIGHT(3/4 in.NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141°C)MAX 591 8.OK PENDENT(3/4 in.NPT) TY42516 7 LEAD COATED 360 360°F(182°C) 560 8.OK UPRIGHT(1/2 in. NPT) TY4851 8 WAX-OVER-LEAD 000 OPENS 286-F(141-C)MAX4 561 8.OK PENDENT(112 in. NPT) TY4951 9 CHROME PLATEDS NOTES 1. Eastern Hemisphere sales only 2. Available in only 8.0 K-factor,155°F(68°C)or 200°F(93°C);requires lead time to manufacture 3. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems("OPEN"indicates sprinkler assembly without glass bulb,button,and sealing assembly) 4. Wax-Over-Lead finish not available for TY3151 Upright or TY3251 Pendent 5.6K 1/2 in.NPT 135°F(57°C) 5. Chrome Plated finish not available for TY3151 Upright 5.6K 1/2 in.NPT 135°F(57°C)and 175°F(79°C)or for TY4851 Upright 8.OK 1/2 in.NPT 360°F(182°C) 6. TY4251 in 175°F(79°C)temperature rating not FM Approved,see Table C for all applicable Listings and Approvals TABLE E SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION TFP151 Page 8of8 Sprinklers that have been exposed to Limited Ordering corrosive products of combustion, but have not operated,should be replaced warrant Procedure if they cannot be completely cleaned by wiping the sprinkler with a cloth or For warranty terms and conditions,visit Contact your local distributor for avail- by brushing it with a soft bristle brush. www.tyco-fire.com. ability.When placing an order, indicate Care must be exercised to avoid the full product name and Part Number damage to the sprinklers before, (P/N). during, and after installation. Sprin- Sprinkler Assemblies with klers damaged by dropping, strik NPT- ing, wrench twist/slippage, or the like, pe Thread Connections S must be replaced. Replace any sprin- Specify: Series TY-B (specify SIN), kler that has a cracked bulb or that has (specify factor), (specify Upright lost liquid from its bulb. See the Instal- to Pendent) Sprinkler with (specify) lation Section. temperature rating, (specify) finish or coating, P/N (See Table E) The owner is responsible for the Recessed Escutcheon inspection,testing,and maintenance of Specify: Style (10 or 40) Recessed their fire protection system and devices Escutcheon with (specify*) finish, P/N in compliance with this document, as (specify") well as with the applicable standards of the National Fire Protection Associ- 'Refer toTechnical Data SheetTFP770 ation such as NFPA 25, in addition to Sprinkler Wrenches the standards of any other authorities Specify: W-Type 6 Sprinkler Wrench, having jurisdiction.Contact the install- P/N 56-000-6-387 ing contractor or product manufacturer with any questions. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Automatic sprinkler are recommended to be inspected,tested,and maintained Wax Sticks(for retouching wrench- by a qualified Inspection Service in damaged wax coating) accordance with local requirements Specify: (specify color, below) Color- and/or national codes. coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135T(57'C)......P/N 56-065-1-135 Red for 155T(68'C) .......P/N 56-065-1-155 Yellow for 175T(79'C) .....P/N 56-065-1-175 Blue for 200T(93'C) and 286'F(141'C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F(141°C)sprinklers is the same as for 200°F(93°C)sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F(93°C)sprinkler which is 150°F(66°C). 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 m 2024 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Jol L1nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a trademark of The Ch.--Company FC,LLC CO® Worldwide www.tyco-fire.com Contacts Series EC-8 — 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers The recessed version of the EC-8 IMPORTANT sprinkler, intended for use in areas with Refer to Technical Data Sheet a finished ceiling, uses either of the fol- TFP2300 for warnings pertaining to lowing two-piece escutcheons: regulatory and health information. Always refer to Technical Data • Style 30 recessed escutcheon Sheet TFP700 for the "INSTALLER • Style 40 recessed escutcheon WARNING" that provides cautions The style 30 recessed escutcheon pro- with respect to handling and instal- vides up to 1/2 in. (12,7 mm) of total lation of sprinkler systems and com- adjustment from the flush pendent ponents. Improper handling and position,whereas,the style 40 provides installation can permanently damage 3/4 in. (19,1 mm)of vertical adjustment a sprinkler system or its compo- from the flush pendent position. The nents and cause the sprinkler to fail adjustment provided by the recessed to operate in a fire situation or cause escutcheons reduces the accuracy to it to operate prematurely. which the fixed pipe drops to the sprin- klers must be cut. Scan the QR code or enter the URL Corrosion resistant coatings, where in a web browser to access the most applicable,are utilized to extend the life up-to-date electronic version of this of copper alloy sprinklers beyond that document. Data rates may apply. which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant 1 coated sprinklers have passed the standard corrosion tests of the appli- ■ cable approval agencies,the testing is not representative of all possible cor- 1■ ■1 rosive atmospheres. Consequently, it R is recommended that the end user be 1 consulted with respect to the suitabil- ity of these corrosion resistant coatings ■ for any given corrosive environment. The effects of ambient temperature, Sprinkler 1 concentration of chemicals, and gas/ ■ chemical velocity, should be consid- Identification docs.jci.com/tycofire/tfp223 ered,as a minimum,along with the cor- rosive nature of the chemical to which Number (SIN) the sprinklers will be exposed. General TY4232. . . . . . . . . . . . Pendent, 8.OK Description ® Note:TY4232 is a re-designation for C4232. p The Series EC-8 Extended Coverage The Series EC-8 Extended Coverage Sprinklers described herein must be Pendent Sprinklers are decorative installed and maintained in compliance glass bulb sprinklers designed for use with this document, as well as with the in light hazard occupancies. They are applicable standards of the NATIONAL intended for use in automatic sprin- FIRE PROTECTION ASSOCIATION, in kler systems designed in accordance addition to the standards of any other with standard installation rules such as authorities having jurisdiction. Failure NFPA 13 for a maximum coverage area to do so may impair the performance of 400 ft2 (37,2 m2), as compared to of these devices. the maximum coverage area of 225 ft2 The owner is responsible for main- (20,6 m2)for standard coverage sprin- taining their fire protection system klers used in light hazard occupancies. and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Page 1 of 4 AUGUST 2022 TFP223 TFP223 Page 2 of 4 Sprinkler Firl Hazard Type Temp. Bulb Liquid Natural Chrome Polyester" brass Plated Light 135°F(57°C) Orange Pendent 1,2,3,5 155°F(68°C) Red Refer to Table B for UL and C-LIL 135°F 57°C e 1,2,3,5 Sensitivity Rating Rec.Pendent ( ) Orange and w/Style 30 Esc. 155°F(68°C) Red 1,2,5 Refer to Table C for FM Sensitivity Rating Rec.Pendent 135°F(57°C) Orange 1,2,5 w/Style 40 Esc. 155°F(68°C) Red NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by Factory Mutual(FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. 'Frame and Deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Technical Components: 3/4" ESCUTCHEON PLATE 1 - Frame 1JN8MINAL �NPT** SEATING SURFACE Data 2 - Button \ Approvals 3- Sealing Assembly 2 __ } UL and C-UL Listed. 4- Bulb FM Approved 5- Compression } 2-1/8" Screw 3 (54,0 mm) NYC Approved. * 1/2" 6- Deflector Note: For complete approval information 2,7 mm) including corrosion resistant status, see *Temperature rating is 4 1-7/16" Table A. The approvals apply to the service indicated on Deflector. AKE-IN (36,5 mm) conditions indicated in the Design Criteria 5 section. **Pipe thread II Maximum Working Pressure connections per ISO 6 175 psi(12,1 bar) 7-1 can be provided on special request. Pipe Thread Connection FIGURE 1 3/4 in.NPT SERIES EC-8(TY4232) Discharge Coefficients EXTENDED COVERAGE PENDENT SPRINKLER K=8.0 gpm/psi'/ (115,21pm/bar'/2) (including bar joists) with a maxi- Temperature Ratings Design mum pitch of one in six as defined 135°F(57°C) Criteria and permitted by NFPA 13. 155°F(68°C) 3. The minimum allowable spacing Note:For approval information,see Table A. The Series EC-8 Extended Cover- between the Series EC-8 Sprin- age Pendent Sprinklers must only klers, to prevent cold soldering, is Finish be installed in accordance with the 8 ft(2,4 m). Sprinkler:See Table A applicable UL and C-UL Listing or FM Recessed Escutcheon:Natural Brass, Approval requirements as indicated 4. The Series Sprinklers are Signal White,Chrome Plated below. Only a style 30 or 40 recessed to be installedd in n accordance with escutcheon is to be used for recessed all other requirements of NFPA 13 Physical Characteristics for extended coverage pendent Installation, as applicable For more Frame ............................Bronze information, see Tables A, B, and C. sprinklers. Button............................Bronze Sealing Assembly..Beryllium Nickel w/TEFLON UL and C-UL Listing Requirements FM Approval Requirements Bulb..................... Glass(3 mm dia.) 1. The Series EC-8 Sprinklers may be The Series EC-8 Extended Cover- Compression Screw.................Bronze age Sprinklers are to be installed Deflector...........................Brass used for the coverage areas shown in accordance with the applicable in Table D, based on maintaining Factory Mutual (FM) Loss Prevention Operation the minimum specified flow rate as a function of coverage area and Data Sheet. Information provided in The glass bulb contains a fluid that hazard group for all of the sprin- the FM Loss Prevention Data Sheet ex expands when exposed to heat.When klers in the design area. relate to, but are not limited to, hydrau- lic design, ceiling slope and obstruc- the rated temperature is reached, the 2. With respect to heat sensitivity, the tions, minimum and maximum fluid expands sufficiently to shatter the Series EC-8 Sprinklers can be used allowable spacing, and deflector-to- glass bulb, allowing the sprinkler to with unobstructed construction ceiling distance. activate and flow water. consisting of flat, smooth ceilings TFP223 Page 3of4 Installation Area Style 135'F(57°C) 155'F(68°C) The Series EC-8 Sprinklers must 16 x 16 Pendent QR QR be installed in accordance with this 16 x 16 Style 30 Recessed QR QR section. General Instructions 16 x 16 Style 40 Recessed QR QR Do not install any bulb type sprinkler 18 x 18 Pendent QR QR if the bulb is cracked or there is a loss 18 x 18 Style 30 Recessed QR SR of liquid from the bulb. With the sprin- kler held horizontally,a small air bubble I 18 x 18 Style 40 Recessed QR SR should be present.The diameter of the I 20 x 20 Pendent QR SR air bubble is approximately 1/16 in. (1,6 mm). 20 x 20 Style 30 Recessed QR SR A leak tight 3/4 in. NPT sprinkler joint I 20 x 20 Style 40 Recessed SR SR should be obtained with a torque of NOTES 10 ft-lb to 20 ft-lb (13,4 N•m to 26,8 SR:Quick Response SR:Standard Response N•m). Higher levels of torque may TABLE B distort the sprinkler inlet with conse- SENSITIVITY RATING FOR UL AND C-UL LISTING quent leakage or impairment of the OF SERIES EC-8 SPRINKLERS sprinkler. Do not attempt to compensate for insufficient adjustment of an escutch- I Area Style 135'F(57°C) 155'F(68°C) eon plate by under-or over-tightening I 16 x 16 Pendent QR QR the sprinkler. Re-adjust the position of the sprinkler fitting to suit. I 16 x 16 Style 30 Recessed QR N/A Step 1.The sprinkler must be installed I 16 x 16 Style 40 Recessed N/A N/A with the deflector parallel to the mount- 18 x 18 Pendent QR QR ing surface. Pendent sprinklers must be installed in the pendent position. 18 x 18 Style 30 Recessed QR N/A Step 2. After installing the style 30 or 18 x 18 Style 40 Recessed N/A N/A 40 mounting plate (or other escutch- I 20 x 20 Pendent QR QR eon, as applicable) over the sprinkler pipe threads, and with pipe thread 20 x 20 Style 30 Recessed QR N/A sealant applied to the pipe threads, 20 x 20 Style 40 Recessed N/A N/A hand tighten the sprinkler into the NOTES sprinkler fitting. QR:Quick Response Ste 3.Wrench tighten pendent s rin- SR:Standard Response p 9 P P N/A:Not Applicable klers using only the W-Type 3 (End A) TABLE C Sprinkler Wrench. Wrench tighten the SENSITIVITY RATING FOR FM APPROVAL recessed pendent sprinklers using OF SERIES EC-8 SPRINKLERS only the W-Type 23 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench as shown in Figures Description Area gpm psi 4 and 5 is to be applied to the sprinkler wrench flats as shown in Figure 1. 16 x 16 26 10.6 TY4232(K=8.0) 18 x 18 33 17.0 Care and Pendent 20 x 20 40 25.0 Maintenance NOTES 1 gpm=3.785 Lpm • 1 ft=0.3048 m 1 psi=0.06895 bar • 1 ft2=0.093 m2 1 aom/ft2=40.74 mm/min The Series EC-8 Sprinklers must be TABLE D maintained and serviced in accordance FLOW CRITERIA FOR UL AND C-UL LISTING with this section. OF SERIES EC-8 SPRINKLERS Before closing a fire protection system main control valve for maintenance wise altered after leaving the factory. be replaced. Also, replace any sprin- work on the fire protection system that Modified sprinklers must be replaced. kler that has a cracked bulb or that has it controls,permission to shut down the Sprinklers that have been exposed to lost liquid from its bulb. For informa- affected fire protection systems must corrosive products of combustion, but tion about replacing a sprinkler,see the be obtained from the proper authorities have not operated,should be replaced Installation Section.) and all personnel who may be affected if they cannot be completely cleaned by this action must be notified. by wiping the sprinkler with a cloth or Frequent visual inspections are rec- S rinklers that are found to be leaking by brushing it with a soft bristle brush. ommended to be initially performed p g for corrosion resistant coated sprin- or exhibiting visible signs of corrosion Care must be exercised to avoid klers, after the installation has been must be replaced. damage to the sprinklers before, completed, to verify the integrity of Automatic sprinklers must never be during, and after installation. Sprin- the corrosion resistant coating.There- painted, plated, coated, or other- klers damaged by dropping, striking, after, annual inspections according wrench twist/slippage,or the like, must to NFPA 25 should suffice; however, TFP223 Page 4 of 4 2-7/8" DIA. "FITTING SIDE" 7/16 1/8" (73,0 mm) 1/2"(12,7 rI TOWARDS SPRINKLER (11,1 3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FITTING FACE OF (57,2 mm) SPRINKLER FITTING (3,22 mm) / WRENCH _ 17777-77__ / RECESS (END"A") MOUNTING MOUNTING FIGURE 4 SURFACE PLATE W-TYPE 3 CLOSURE SPRINKLER WRENCH 1-5/16"(33,3 mm) 1-1/16"(27,0 mm) WRENCH �- RECESS FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON h_rr 1 2-7/8" DIA. ; 9/16 1/4" (73,0 mm) 3/4"(19,1 mm) I (14,3 6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) © 0 FACE OF r (57,2 mm) L SPRINKLER 1/81, -- FITTING (3,2 mm) FIGURE 5 W-TYPE 23 RECESSED V — SPRINKLER WRENCH i MOUNTING MOUNTING Sprinkler Assemblies with NPT SURFACE PLATE Thread Connections CLOSURE Specify: Series EC-8 (TY4232), K=8.0, Extended Coverage (Light Hazard) 1-5/16" (33,3 mm) Pendent Sprinkler, (specify) tem- 13/16"(20,6 mm) perature rating, (specify) finish, P/N FIGURE 3 (specify): SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY 135°F(57°C) WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT Natural Brass.............PSN 50-801-1-135 STYLE 40 RECESSED ESCUTCHEON Signal White 03) Polyester ......................PSN 50-801-4-135 Chrome Plated............PSN 50-801-9-135 instead of inspecting from the floor It is recommended that automatic 155°F(68°C) level, a random sampling of close-up sprinkler systems be inspected,tested, Natural Brass.............PSN 50-801-1-155 visual inspections should be made, so and maintained by a qualified Inspec- Signal White(RAL9003) as to better determine the exact sprin- tion Service in accordance with local Polyester ................PSN 50-801-4-155 kler condition and the long term integ- requirements and/or national codes. Chrome Plated............PSN 50-801-9-155 rity of the corrosion resistant coating, Recessed Escutcheon as it may be affected by the corrosive Limited Specify: Style (30 or 40) Recessed conditions present. Escutcheon with (specify*) finish, P/N The owner is responsible for the Warranty (specify") inspection,testing,and maintenance of "Refer to Technical Data Sheet TFP770 their fire protection system and devices For warranty terms and conditions,visit Sprinkler Wrench in compliance with this document, as w`n'w•tyco-fire.com. Specify: W-Type 3 Sprinkler Wrench, well as with the applicable standards P/N 56-895-1-001 of the NATIONAL FIRE PROTECTION Ordering ASSOCIATION such as NFPA 25, in Specify:W-Type 23 Recessed Sprinkler addition to the standards of any other Procedure Wrench, P/N 56-000-6-838 authorities having jurisdiction. The installing contractor or sprinkler man- Contact your local distributor for avail- ufacturer should be contacted relative ability.When placing an order, indicate to any questions. the full product name and Part Number (P/N). 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 m 2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Jol L1nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a trademark of The Ch.—a Company FC,LLC VicFlex"" Sprinkler Fittings Series AH2-300 and AH2-CC-300 ✓ctaulicg Braided Flexible Hose Assemblies 10.84 FIexTM 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2-300 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.757140mm straight reducer • AH2-CC-300 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.757140mm straight reducer • Sprinkler Reducers: • Sprinkler Connections: 1/2" and 3/4715 and 20 mm • Straight Lengths: 5.75"/140mm, 97230mm, 13"/330mm • 90' Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Inlet Connections: • 1725mm NPT or BSPT • 1" IGS connection ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. 1 Aictaull victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Brackets • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB10 for Armstrong®TechZoneTI ceilings • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature • 2250F/1070C Maximum Working Pressure • 300 psi/2068 kPa Connections • To adapter nipple (inlet) via • 1725.4 mm Grooved IGS • 1725.4 mm NPT or BSPT male thread • To sprinkler head (outlet) via 1/2" or 3/4715 mm or 20 mm Minimum Bend Radius • 87200 mm Maximum Number of Bends per Flexible Drop • See section 5.0 Maximum K-Factor of Sprinkler to be Connected to Reducer • K8.0/11,5 (S.I.) (1/2715mm reducer) • K14.0/20,2 (S.I.) (3/4720mm reducer) 2.0 CERTIFICATION/LISTINGS FM 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaul�c° victaulic.com 3.0 SPECIFICATIONS — MATERIAL Series AH2-300 • Flexible Hose: 300-series stainless steel • Collar/Weld Fitting: 300-series stainless steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc-Plated • Reducers (1/2 or 3/4"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC-300 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2'715 mm or 3/4'720 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Grade"E" EPDM (Type A)Vic-Plue" Pre-lubricated Gasket • EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. Note:Reference should always be made to publication 1-100,Victaulic Field Installation Handbook for gasket lubrication instructions. Note:Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01,Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com 4.0 DIMENSIONS Product Details - Series AH2-300 Braided Hose Item Description 1 Flexible Hose 2 Isolation Ring 5 6 3 4 3 Gasket 4 Nut 5 Branch Line Nipple �- A -� 6 Braid B 7 Collar/Weld Fitting Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1220 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC-300 Braided Hose Item Description 5 1 Flexible Hose 1 6 7 3 4 2 Isolation Ring 3 Gasket 4 Nut S Style 108 Coupling 6 Braid A 7 Collar/Weld Fitting B Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1220 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic° victaulic.com 4.1 DIMENSIONS Standard Reducer 5.75"/140 mm straight reducer Optional Reducer 9.0"/229 mm straight reducer --------------------------------- 13.0"/330 mm straight reducer 2.627 2.62"/ 66.5 mm T6.57"/ 4.837 166.9 mm 122.7 mm L) i Short 90'elbow reducer Long 90'elbow reducer NOTE • The Short 90'elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic° victaulic.com 4.2 DIMENSIONS WcRex Brackets 3 Style ABl • Suspended Ceilings • Hard-Lid Ceilings ' Item Description 1 24"/610mm or 48"/1219mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 End Bracket 3 Style A132 3 ° B • Hard-Lid Ceilings Item Description ° 1 24"/610mm or 48'/1219mm Square Bar' 2 Patent-Pending Adjustable Center bracket 3 End Bracket(adjustable) e Style AB3 • Surface Mount Applications Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system 1 z 3 Item Description 1 24"/610mm or 48'/1219mm Square Bar' 3 2 Patent-Pending Adjustable Center bracket 3 Adjustable End Bracket for Hat Furring Channel 3 Style AB5 • Hard-Lid Ceilings z Item Description 1 24'7610 mm or 48'71220 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 3 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic° victaulic.com 4.2 DIMENSIONS (CONTINUED) WcFlex Brackets Style AB7 • Suspended Ceilings • Hard-Lid Ceilings 2 Item Description 1 24"/610mm or 48"/1219mm Square Bar 2 Patented 1-Beez®Center Bracket 3 End Bracket 3 Style AB7 Adjustable 3 • Suspended Ceilings • Hard-Lid Ceilings z Item Description 1 700mm or 1400mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 End Bracket(adjustable) 3 Style AB8 • Hard-Lid Ceilings 2 Item Description 1 I 700 mm or 1400 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 0 Style AB10 • Suspended ceilings 3 2 • Armstrong°TechZone" 1 ® 3 Item Description s 1 6'/152mm Square Bar' 2 Patented 1-Beez®Center Bracket 3 End Bracket Style AB12 • Suspended ceilings 2 • Hard-Lid ceilings �•. �.\ ®® Item Description 1 Style AB12 Bracket Body 2 Set Screw 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctaulic° victaulic.com 4.2 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount 3 • Cantilever mount • Temporary mount in exposed ceilings z Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw,Serated Flange,M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body ° 5 Cap Screw,Serated Flange,M6 x 1 x 15.24, ° T25 Torx Drive Recessed Style ABMM • Surface mount 2 • Stand-off mount Item Description 1 Style ABMM Bracket Body i 2 Cap Screw,Serated Flange,M6 x 1 x 15.24, T25 Torx Drive Recessed 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic° victaulic.com 4.3 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB1 Bracket / R � A :fied See Chart 28/8760 mm 21M6"/68 mm max.hole max.hole 2"/51 mm 21/s'"/60 mm 4.4"/ min.hole min.hole 113 mm icalTypical ceilinggrid See note ceil 247610 mm or V27 V38 48"/1219 mm on Pendent Center Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4"Max Recess 1/2"Max Recess 3/4"Max Recess 1/2"Max Recess inches inches inches inches mm mm mm mm "R"Minimum 8.0 Bend Radius 203 W,Minimum Required 14.6 16.1 5.8 5.8 Installation 371 409 147 147 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 9 ✓ctaulic° victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket jele A See Chart t 1.87 2'M6"/68 mm 2'/8760 mm 2'/8760 mm # ly 45 mm 2 x 4" ScB2 max.hole max.hole max.hole Stud 21/8760 mm 2751 mm 2751 mm min.hole min.hole min.hole 3.57 I I89 mmI I I 167406 mm�� Finished Stud C/C ceiling 4 + V38 V27 V27 Pendent Sidewall Hose Clearance Chart V2707 V3802 V2709 3/4"1 20mm 1/2"113 mm 3/4!'120mm Max Recess Max Recess Sidewall inches inches inches mm mm mm "R"Minimum 8.0 Bend Radius 203 "A"Minimum Required 12.2 13.6 12.1 Installation 310 345 307 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4"1 20mm 3/4"1 20mm 1/2"113 mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R"Minimum Bend Radius "A"Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctaulic° victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket R A 23/s"/60 mm 211A6"/68 mm See Chart max.hole max.hole 2"/51 mm 23/8760 mm min.hole min.hole 5/8"/15.9 mm Typical Typical finished ceiling tile ceiling face See note 1/8723 mm Typical 16"/406 mm— Typical V27 V38 247610 mm on Center ceiling grid Pendent Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4"Max Recess 1/2'Max Recess 3/4"Max Recess '/2"Max Recess inches inches inches inches mm mm mm mm "R"Minimum 8.0 8.0 _ Bend Radius 203 203 "A"Minimum Required 14.8 16.2 8.0 5.9 Installation 376 411 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 11 ✓ctaul;c° victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket R A See Chart Bracket Assembly 21/8'/60 mm 21M6768 mm 21/a"/60 mm Style AB5 2.37 max.hole max.hole max.hole 7 mm 2751 mm 2'/8760 mm 2"/51 mm I I I I min.hole min.hole min.hole n I II u I II II II II II 3.67 2x4" if ii ii 92mm MetalStud u u I �I I s/8^/ Finished 15.9 mm ceiling face 16"/406 mm Drywall Stud C/C V27 V38 V27 Pendent Sidewall Hose Clearance Chart V2707 V3802 V2709 3/4"1 20mm 1/2"113 mm 3/4"1 20mm Max Recess Max Recess Sidewall inches inches inches mm mm mm "R"Minimum 8.0 Bend Radius 203 "A"Minimum Required 12.0 13.7 12.1 Installation 305 348 307 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2709 V3802 3/4"1 20mm 1/2'1 13 mm 3/4"1 20mm 1/2"1 13 mm Max Recess Max Recess Sidewall Max Recess inches inches inches inches mm mm mm mm "R"Minimum _ Bend Radius "A"Minimum Required 3.5 4.9 3.6 3.3 Installation 89 124 91 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctaulic° victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 28/8760 mm 2"/6'/68 mm Bracket max.hole max.hole Assembly 2751 mm 23/s"/60 mm A Style AB11 min.hole min.hole See Chart 3.0"/ 76 mm ff ff II II MILLI 1.7"/43 mm Finished Typical /8"/15.9 mm ceiling face ceiling grid Typical ceiling tile See Note 247610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow "72707 V3802 3/4"1 20mm 1/2"113 mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctaulic° victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.75"/140mm Reducer M1n1n,,h,d Ceiling Face;! r1%mch/ 29 rnn, II I li II Square bar No minal length 47355 6 Unfinished See Table _T Fi T a) r gth 1%inch/ Ceiling Face Yx A inch/ 2 mm rn 3mm Square bar V�inch/ A' 3mm See Table "B"See Table 'B'See Table `Finished Face of --- LEE Finished Face of Vonch/16- rn 'A-inch/l 6-mm Typical Ceiling Typical Ceiling V2707 I/Y71 2.7 mm MAX.RECESS V2707W/19-MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4119MM 3/4719MM 3/4119MM 3/4719MM 3/47 19MM Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm A Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 2.227 56 mm Op i 3.937 .94"/ loomm 75 mm 3694-,/ 0.287 0 0 1, 100 0 mm 7 mm 10.84 7491 Rev.C Updated07/2019 0 2019 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaul�c° victaulic.com 4.10 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C 33/4/ 95.3 mm I 4 s 2 B A ,I 23/8760 mm max.hole 2751 mm min.hole Hose Clearances inches inches inches inches inches Dimension mm mm mm mm mm WallThickness 2 4 6 8 10 "A" 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 T" 319 402 503 268 351 452 300 402 1 351 300 Bend Radius 8 "R" 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 15 ✓ctaulic° victaulic.com 4.11 DIMENSIONS Branchline clearances Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart A See chart A See chart i FemaleThreaded Weld Outlet No.142 Grooved Weld Outlet 2750 mm 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm Minimum 8 Minimum 8 R Bend Radius 203 R Bend Radius 203 A Min. 11 A 3 6 Min. 13.1 333 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 16 ✓ctaulic° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA FM Series AH2-300 and AH2-CC-300 Braided Hoses Style AB1, AB2, AB3, AB4, ABS, AB7, A137 Adj., ABB, AB1O, AB12, ABBA, ABMM VicFiex Brackets Equivalent Length of Maximum Number Length of Stainless Steel Sprinkler Outlet 1733.7mm of 90'Bends at 8"/200mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches Imperial mm S.I. inches/type feet/meters 31 5.6 1/2"/Straight 13.8/4.2 2 790 8.1 1/2"/90'Elbow 23.5/7.1 36 5.6 1/2"/Straight 16.6/5.1 2 915 8.1 1/2790"Elbow 25.6/7.8 48 5.6 1/2"/Straight 23.4/7.1 3 1220 8.1 1/2"/90°Elbow 30.7/9.3 60 5.6 1/2"/Straight 30.2/9.2 4 1525 8.1 1/2790"Elbow 35.9/10.9 72 5.6 1/2"/Straight 37.0/11.3 4 1830 8.1 1/2"/90°Elbow 41.1/12.5 31 8.0 3/4"/Straight 20.7/6.3 2 790 11.5 3/4"/90°Elbow 20.5/6.2 36 8.0 3/4"/Straight 25.0/7.6 2 915 11.5 3/4"/90°Elbow 24.6/7.5 48 8.0 3/4"/Straight 35.5/10.8 3 1220 11.5 3/4"/90"Elbow 34.7/10.6 60 8.0 3/4"/Straight 39.6/12.1 4 1525 11.5 3/4"/90°Elbow 40.1/12.2 72 8.0 3/4"/Straight 43.5/13.2 4 1830 11.5 3/4"/90°Elbow 45.2/13.7 31 11.2 -3/4"/Straight 17.8/5.4 2 790 16.1 3/4"/90°Elbow 18/5.5 36 11.2 3/4"/Straight 22.2/6.7 2 915 16.1 3/4"/90"Elbow 22.1/6.7 48 11.2 3/4"/Straight 32.9/10.0 3 1220 16.1 3/4"/90°Elbow 32.1/9.8 60 11.2 3/4"/Straight 36.8/11.2 4 1525 16.1 3/4"/90"Elbow 37.1/11.3 72 11.2 3/4"/Straight 40.5/12.3 4 1830 16.1 3/4"/90°Elbow 41.9/12.7 31 14.0 3/4"/Straight 14.9/4.5 2 790 20.2 3/4"/90°Elbow 15.5/4.72 36 14.0 3/4"/Straight 19.4/5.9 2 915 20.2 3/4"/90°Elbow 19.6/5.9 48 14.0 3/4"/Straight 30.3/9.2 3 1220 20.2 3/4"/90"Elbow 29.5/8.9 60 14.0 3/4"/Straight 33.9/10.3 4 1525 20.2 3/4"/90°Elbow 34.1/10.4 72 14.0 3/4"/Strai ht 37.5/11.4 4 1830 20.2 3/4"/90°Elbow 38.6/11.7 FM NOTES: • Series AH2-300 Braided Flexible Hoses have been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods,per FM 1637.Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE:A 48-inch Series AH2-300 hose installed with two 30'bends and two 90'bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 17 ✓ctaulic° victaulic.com 6.0 NOTIFICATIONS A WARNING _ Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal,adjustment,or maintenance of any Victaulic products. • Wear safety glasses, hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current,applicable National Fire Protection Association(NFPA 13, 13D, 13R,etc.)standards,or equivalent standards,and in accordance with applicable building and fire codes.These standards and codes contain important information regarding protection of systems from freezing temperatures,corrosion, mechanical damage,etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level,operating temperature,chloride level,oxygen level,and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 18 ✓ctaull victaulic.com 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/linearft N/linearm 31/790 0 6 5.2 23 2.6 38 36/915 �9 5.5 25 2.8 40 48/1220 1 2 6.3 28 3.1 46 60/1525 1 5 7.0 31 3.5 51 72/1830 1 8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 36/915 p 9 6.4 29 1.6 23 48/1220 1 2 7.2 32 1.8 26 60/1525 1 5 7.9 35 2.0 29 72/1830 1 8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • Water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • Bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min.Allowable Uniform Load Suspension System ft/m Ib/linearft N/linearm Light MP 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 19 ✓ctaulic° victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends zX Minimum Minimum (Z2X i Minimum bend radius bend radius bend radius I I OR I Minimum I OR I bend radius I I <\90° — \ I \ I , I Minimum Minimum bend radius i Minimum bend radius bend radius I Minimum _ bend radius Minimum I bend radius NOTE • For out-of-plane(three-dimensional)bends,care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10, -VICFLEX-AB4-AB9, or waive any provision of Victaulic Company's standard conditions of sale,installation -VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 20 ✓ctauliic° Firel-ockT"" Installation-Ready" Rigid Couplings ✓ctaulic° Style 009V, Style 009N and Style 109 10.64 Style 009V Style 009N Style 109 Patented Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes • Style 009V: 11/4— 12"/DN32 — DN300 • Style 009N: 11/4— 12"/DN32— DN300 • Style 109: 11/4—47DN32— DN100 Pipe Material • Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses, contact Victaulic • For exceptions, reference section 6.0 Notifications Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) to 365 psi/2517 kPa • Working pressure dependent on material, wall thickness and size of pipe Function • Joins carbon steel pipe with grooved ends conforming to publication 25.01: Victaulic Original Groove System (OGS) Specifications • Provides a rigid pipe joint designed to restrict axial or angular movement Pipe Preparation • Cut or roll grooved in accordance with publication 25.01 2.0 CERTIFICATION/LISTINGS C&us fM OLPCB VdS ( E LISTED APPROVED LPS 1219:Issue 3.1 009N:G4090023 EN 10311 Cert/LPCB Ref.104-1a/36 109:G421013 CPR(EU) No.305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. 1 deictsullid victaulic.com 3.0 SPECIFICATIONS — MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange coating ❑ Red coating (standard for EMEA-I and Asia Pacific) ❑ Optional for Style 009N and 009V: Galvanized per ASTM A123 (Hot Dipped) or ASTM A1059 (Thermo-Diffusion) ❑ Optional for Style 109: Mechanically Galvanized per ASTM B695 (available only in North America and Latin America). Gasket: (specify choice) ❑ Grade "E" EPDM (Type A) Vic-Pluem Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air)fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES • Reference should always be made to publication 1-100,Victaulic Field Installation Handbook for gasket lubrication instructions. • Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to publication 05.01,Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • The gasket pre-lubrication will appear white to slightly amber in color.The color will not impact gasket or coupling performance. Bolts/Nuts: (specify choice) J Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of(imperial) ASTM A449 or (metric) ISO 898-1 Class 9.8 (M10-M16) or Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of(imperial hex nuts) ASTM A563 Grade B or (metric hex nuts) ISO 898-2 Class 10 (M12-M16) or Class 8 (M20 and greater). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn5 finish (imperial) Type III or (metric) Type II. ❑ Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' ' Optional bolts/nuts are available in imperial size only. Coupling Linkage (Style 109 only): High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type III Finish. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctsuliid victaulic.com 4.0 DIMENSIONS Style 009V Two-Bolt Installation-Ready" Coupling Y Z Y Z X X Style 009V Pre-Assembled Style 009V Joint Assembled Size Bolt/Nut Dimensions Actual Maximum Maximum Allow. Pre-Assembled Joint Assembled Approx. Outside Working End Pipe End Weight Nominal Diameter Pressure2 Load2 Separation3 Size X Y X Y Z (Each) inches inches Lbs. inches inches inches inches inches inches inches inches lb DIN mm N I mm mm Qty. mm mm mm mm mm mm kg 1 1/4 1.660 365 790 0.10 3/8 x 2 3.25 4.81 2.88 4.75 2.13 1.7 DN32 42.4 2517 3514 2.54 2 M10 x 51 82 122 74 120 54 0.8 1 1/2 1.900 365 1035 0.10 3/8 x 2 3.50 5.06 3.13 5.00 2.13 1.7 DN40 48.3 2517 4604 2.54 2 M10 x 51 88 128 80 128 54 0.8 2 2.375 365 1617 0.12 3/8 x 21/2 4.06 5.63 3.63 5.63 2.13 2.1 DN50 60.3 2517 7192 3.05 2 M10 x 63 104 142 92 142 54 1.0 21/2 2.875 365 2370 0.12 2 3/8 x 21/2 4.56 6.06 4.06 6.06 2.13 2.2 73.0 2517 1 10542 3.05 1 M 10 x 63 116 154 1 104 154 1 54 1.0 3.000 365 2580 0.12 2 3/8 x 21/2 4.69 6.13 4.19 6.13 2.13 2.3 DN65 76.1 2517 11476 3.05 M10 x 63 120 156 106 156 54 1.0 3 3.500 365 3512 0.12 2 3/8 x 21/2 5.19 6.81 4.63 6.69 2.19 2.6 DN80 88.9 2517 15622 3.05 M10 x 63 132 174 118 170 56 1.2 4 4.500 365 5805 0.17 3/8 x 21/2 6.38 7.94 5.75 7.75 2.25 3.5 DN100 114.3 2517 25822 4.32 2 M10x63 162 202 146 196 58 1.6 5.500 365 8672 0.17 2 1/2 x 3 7.81 9.50 7.19 9.38 2.31 5.6 DN125 1 139.7 2517 1 38574 4.32 1 M12 x 76 198 242 1 182 238 1 58 2.5 6.500 365 12112 0.17 2 1/2 x 3 8.88 10.56 8.19 10.44 2.31 6.3 165.1 2517 53876 4.32 M12 x 76 226 268 208 266 58 2.9 6 6.625 365 12582 0.17 2 1/2 x 3 9.00 10.69 8.31 10.56 2.31 6.3 DN150 168.3 2517 55968 4.32 M12 x 76 228 272 212 268 58 2.9 8.515 365 20712 0.17 2 1/8 x 31/8 11.25 13.63 10.44 13.50 2.81 13.0 216.3 2517 92132 4.32 M 16 x 92 286 346 266 342 72 5.9 8 8.625 365 21326 0.17 2 1/8 x 31/8 11.31 13.75 10.56 13.63 2.81 13.0 DN200 1 219.1 2517 1 94862 4.32 1 M16 x 92 288 350 1 268 346 1 72 5.9 10 10.750 365 33127 0.25 7/8 x 6 14.13 17.50 13.25 17.13 2.94 25.0 DN250 273.0 2517 147358 6.4 2 M22 x 152 358 444 336 434 74 11.5 12 12.750 365 46600 0.25 7/8 x 6 16.38 19.50 15.63 19.25 2.94 30.0 DN300 323.9 2517 207290 6.4 2 M22 x 152 416 496 396 488 74 13.5 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 009V Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Nan-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctsulid victaulic.com 4.1 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling Y Z. Y Z X X 1 I i Style 009N Pre-Assembled Style 009N Joint Assembled Size Bolt/Nut Dimensions Actual Maximum Maximum Allow. Approx. Working End Pipe End Pre-assembled Joint Assembled Weight Outside g P g Nominal Diameter Pressure2 Load2 Separation3 Size X Y X Y Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DN mm kPa N mm Qty. mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 2 3/8 x 2 3.13 5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 1 2.54 M10 x 51 79 127 70 127 51 0.6 1 1/2 1.900 365 1035 0.10 2 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 M10 x 51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 3/8 x 21/2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7192 3.05 21 M10 x 63 102 143 89 1 143 51 1 0.9 21/2 2.875 365 2370 0.12 2 3/8 x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 M10 x 63 114 156 102 156 51 1.0 3.000 365 2580 0.12 2 3/8 x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 M10 x 63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/a x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 M10 x 63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 3/8 x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 2 M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 2 3/8 x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23032 4.32 M 10 x 63 143 187 137 187 54 1.4 5 5.563 365 8872 0.17 2 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 1 39464 4.32 M12 x 76 184 235 1 171 232 57 2.3 5.250 365 7901 0.17 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35146 4.32 2 M12 x 76 1 168 229 162 229 57 2.2 5.500 365 8672 0.17 2 1/2 x 3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38574 4.32 M12 x 76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 1/2 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 55968 4.32 2 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 2 1/2 x 31/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49812 4.32 M 12 x 83 200 254 187 251 57 2.5 6.500 365 12112 0.17 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53876 4.32 2 M12 x 83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 2 5/8 x 4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94862 4.32 M16x101 276 340 260 333 64 5.2 8.515 365 20712 0.17 2 5/8 x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.3 2517 92132 4.32 M16 x 101 270 337 260 257 67 5.2 10 10.750 300 27229 0.25 7/8 x 61/2 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121120 6.40 2 M22 x 165 349 432 337 435 70 1 10.3 12 12.750 300 38303 0.25 7/s x 61/2 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.40 2 M22 x 165 1 406 1 483 1 394 1 486 1 70 12.5 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 009N Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctsulid victaulic.com 4.2 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Z Z YL Yg Yg YL 1 X - X Style 109 Pre-Assembled Style 109 Joint Assembled Size Bolt/Nut Dimensions Weight Actual Max. Max. Allow. Pipe Pre-Assembled Assembled Outside Work. End End Sep. Approx. Nominal Diameter Press.2 Load2 Maximum3 Qty. Size YL YB X Z YL YB X Z (Each) inches inches psi Lbs. inches inches inches inches inches inches inches inches inches inches lb DIN mm kPa N mm mm mm mm mm m m mm mm mm mm kg 11/4 1.660 365 790 0.10 1 3/8 x 21/4 1.97 2.49 3.17 1.95 1.93 2.59 2.84 1.95 1.5 DN32 42.4 2517 3514 2.54 M10 x 57 50 63 81 50 49 66 72 50 0.7 11/2 1.900 365 1035 0.10 1 3/8 x 21/4 2.13 2.60 3.41 1.95 2.10 2.68 3.07 1.95 1.6 DN40 48.3 2517 4603 2.54 M10 x 57 54 66 87 50 53 68 78 50 0.7 2 2.375 365 1617 0.12 1 3/8 x 21/4 2.32 2.85 3.76 1.98 2.29 2.95 3.45 1.98 1.9 DN50 60.3 2517 7192 3.048 M10 x 57 59 72 96 50 58 75 88 50 0.9 21/2 2.875 365 2370 0.12 1 3/8 x 21/4 2.63 3.09 4.29 1.99 2.61 3.15 3.93 1.99 2.1 73.0 2517 1 10540 3.048 1 IM10x571 67 78 1 109 51 1 66 80 1 100 51 1 1.0 3.000 365 2580 0.12 1 7/16 x 2 3/4 2.68 3.22 4.56 2.03 2.64 3.45 4.22 2.03 2.4 DN65 76.1 2517 11476 3.048 M11 x69 68 82 116 52 67 88 107 52 1.1 3 3.500 365 3512 0.12 1 7/16 x 2 3/4 2.93 3.53 5.13 2.07 2.89 3.78 4.67 2.07 2.7 DN80 88.9 2517 15620 3.048 M11 x69 74 90 130 53 73 96 119 53 1.2 4 4.500 300 4771 0.17 1 7/16 x 2 3/4 3.47 4.01 6.03 2.08 3.43 4.22 5.56 2.08 3.5 DN100 114.3 2068 21223 4.318 M11 x69 88 102 153 53 87 107 141 53 1.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 109 Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the "QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctsulid victaulic.com 5.0 PERFORMANCE Style 009V Two-Bolt Installation-Ready Coupling Listings/Approvals Size cULus FM Actual Outside Nominal Diameter Sch. 104 Sch.404 Sch. 10 Sch.40 psi psi psi psi inches inches kPa kPa kPa kPa D N mm bar bar bar bar 1'/4 1.660 365 365 365 365 DN32 42.4 2516 2516 2515 2515 25 25 25 25 365 365 365 365 1 2516 2516 2515 2515 DN40 48.3 8.3 25 25 25 25 2 2.375 365 365 365 365 DN50 60.3 2516 2516 2515 2515 25 25 25 25 21/2 2.875 365 365 365 365 73.0 2516 2516 2515 2515 25 25 25 25 3.000 3658 — 365 365 DN65 76.1 2516" — 2516 2516 25" — 365 365 3 3.500 365 365 365 365 DN80 88.9 2516 2516 2515 2515 25 25 25 25 4 4.500 365 365 365 365 DN100 114.3 2516 2516 2515 2515 25 25 25 25 5.500 3009 — 365 365 DN125 139.7 20689 — 2516 2516 209 — 25 25 6.500 30010 — 300 365 165.1 206810 — 2068 2516 2010 — 20 25 6 6.625 300 365 300 365 DN150 168.3 2068 2516 2065 2515 20 25 20 25 8.515 3007 — 300 365 216.3 20687 — 2068 2516 207 — 20 25 3006 365 3005 365 D 8 85 2 9.1 20686 2516 20655 2515 206 25 205 25 10 10.750 3006 365 3006 365 DN250 273.0 20686 2516 20655 2515 206 JL 25 205 25 12 12.3.9 3006 365 3005 365 DN 2 323.9 20686 2516 20655 2515 206 25 205 25 4 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009V for details concerning when supplemental lubrication is required. 5 FM approved for 0.188"pipe wall. 6 cULus listed for 0.188"pipe wall. 7 cULus listed for JIS G3452 5.8mm pipe wall. 8 cULus Listed for EN10217 2.6mm pipe wall. 9 cULus Listed for EN10216 4.Omm pipe wall. 10 cULus Listed for EN10216 4.5mm pipe wall. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctsulid victaulic.com 5.1 PERFORMANCE Specialty Pipe Style 009V Two-Bolt Installation-Ready Coupling Listings/Approvals Pipe Type Size Pressure Rating Pressure Rating UIL FM psi psi inches kPa kPa DN bar bar 1 1/4—4 300 300 DN32—DIN 100 2068 2065 20 20 1 1/4-2 300 EL DN32—DN50 — 2065 20 1 1/4-6 300 300 MF DN32—DN150 20668 22665 20 11/2—4 300 300 FF DN40—DN100 2068 2065 20 20 11/4-4 300 DN32—DN 100 — 2065 HF 20 2-4 300 — DN50—DN 100 2068 — 20 — 1 1/4-2 300 300 ET40 DN32—DN50 2068 2065 20 20 1 1/4-2 300 300 EZT DN32—DN50 2068 2065 20 20 1 1/4-2 300 300 MT DN32—DN50 2068 2065 20 20 11/4—2 300 300 MLT DN32—DN50 2068 2065 20 20 1 1/4—4 175 300 Easy-Flow DN32—DN100 1206 2065 12 20 11/4-4 175 WG5,WG5E,WF5,WL7 DN32—DN100 1206 — 12 1 1/4—4 175 300 WG7,WG7E DN32—DN100 1206 2065 12 20 1 1/4-2 300 WLS DN32—DN50 — 2065 20 1 1/4-2 300 GL DN32—DN50 200665 20 NOTES • Easy Flow=Steel pipe manufactured by Borusan Mannesmann Boru • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,WFlow 5 steel pipe • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. manufactured by Wuppermann Stahl GmbH. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,Wgalweld 7E,WLight 7 steel pipe • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • GL=GL steel pipe manufactured by Wheatland Tube Co. • HF=Hydroflow sch 7 steel pipe manufactured by Nucor Tubular Products Inc. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctsulid victaulic.com 5.2 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus1116 FM16 VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch.40 Sch. 10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 11/4 1.660 365JE 365 363 363 363 363 DN32 42.4 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 11/2 1.900 365 365 363 363 363 363 DN40 48.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 2 2.375 365 365 363 363 363 363 DN50 60.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 21/2 2.875 365 365 363 363 363 73.0 2516 2516 2503 2503 — 2503 25 25 25 25 25 3.000 36512 36313 363 363 DN65 76.1 251612 — 250313 — 2503 2503 2512 2513 25 25 3 3.500 365 365 363 363 363 363 DN80 88.9 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 4 4.500 365 365 363 363 363 363 DN100 114.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 4.250 363 363 108.0 — — 2503 2503 — — 25 25 5 5.563 365 365 363 363 232 363 141.3 2516 2516 2503 2503 1600 2503 25 25 25 25 16 25 36313 0 5.25.250 — — 250313 — — — 2513 29014 36313 232 363 5.500 DN125 5.500 199914 — 250313 — 1600 2503 2014 2513 16 25 6 6.625 300 365 300 363 232 363 DN150 168.3 2068 2516 2068 2503 1600 2503 20 25 20 25 16 25 6.250 36313 159 — — 250313 — — — 2513 11 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 12 cULus listed for DIN 2458(EN 10220)2.6 mm pipe wall. 13 FM approved for BS 1387(EN 10255)Medium 3.6 mm pipe wall. 14 cULus listed for EN 10220 4.0 mm pipe wall. 15 cULus listed for EN 10255 4.5 mm pipe wall. 16 For optional stainless steel fasteners,reference the UL Product IQ and FM Approval Guide websites for working pressure ratings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctsulid victaulic.com 5.2 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULUS1720 FM20 VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch.40 Sch. 10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON mm bar bar bar bar bar bar 6.500 29019 36318 363 165.1 199919 — 250318 — — 2503 2019 2518 25 8.625 30022 365 30021 363 232 363 8 206822 2516 206821 2503 1600 2503 DN200 219.1 2022 25 2021 25 16 25 23 18 8.515 199923 — 250318 — — — 216.3 2023 2518 .750 30022 300 30021 300 290 10 10 DN250 273.0 0 206822 2068 206821 2068 — 2000 2022 20 2021 20 20 30022 300 25021 300 290 12 12.750 206822 2068 172021 2068 — 2000 DN300 323.9 2022 1 20 1721 1 20 1 20 17 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 18 FM approved for BS 1387(EN 10255)Medium 3.6 mm pipe wall. 19 cULus listed for EN 10255 4.5 mm pipe wall. 20 For optional stainless steel fasteners,reference the UL Product IQ and FM Approval Guide websites for working pressure ratings. 21 FM Approved for 0.188"pipe wall. 22 cULus Listed for 0.188"pipe wall. 23 cULus Listed for JIS G3452 pipe. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 9 ✓ctsulid victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating UL FM psi psi inches kPa kPa Pipe Type DN bar bar 1'/a—4 300 EF DN32—DN 100 2068 — 20 300 300 EL 1'/a-2 2068 2068 DN32—DN50 20 20 3-4 300 EZF DN80—DN 100 2068 — 20 300 300 1'/a—4 2068 2068 DN32—DN100 MF 20 20 6 175 175 DN150 1206 1207 12 12 1'/2-4 300 FF DN40—DN 100 20668 20 300 1 Ya—2 _ ET40 DN32—DN50 2068 20 1'/a—2 300 300 EZT DN32—DN50 2068 2068 20 20 300 300 MT 1 Ya—2 2068 2068 DN32—DN50 20 20 1'/a 2 300 MLT DN32—DN50 — 2068 20 1'/a—4 300 Easy Flow DN32—DN100 — 2068 20 1'/a—4 300 300 WG5,WG5E,WF5,WG7,WG7E,WL7 DN32—DIN 100 2068 2068 24 20 300 DN65 TF(Tex-Flow) 2'/-ID 4 DN 100 — 2068 20 1'/a—2 300 WLS DN32—DN50 — 2068 20 1'/a—2 300 GL DN32—DN50 2068 20 NOTES • Easy Flow=Steel pipe manufactured by Borusan Mannesmann Boru • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,WFlow 5 steel pipe • EZF=EZ-Flow,steel pipe manufactured by Northwest Pipe Co. manufactured by Wuppermann Stahl GmbH. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,Wgalweld 7E,WLight 7 steel pipe • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • GL=GL steel pipe manufactured by Wheatland Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctsulid victaulic.com 5.4 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus24 FM VdS LPCB Actual Outside Sch. 10 Sch.40 Sch. 10 Sch.40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON m m bar bar bar bar bar bar 11/4 1.660 365 365 365 365 232 363 DN32 42.4 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 11/2 1.900 365 365 365 365 232 363 DN40 48.3 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 2 2.375 365 365 365 365 232 363 DN50 60.3 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 21/2 2.875 365 365 365 365 73.0 2516 2516 2517 2517 — — 25 25 25 25 3.000 365 365 232 363 DN65 — — 2517 2517 1600 2503 25 25 16 25 3 3.500 365 365 365 365 232 363 DN80 88.9 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 4 4.500 300 300 300 300 290 DN100 114.3 2068 2068 2068 2068 — 2000 20 20 20 20 24 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. NOTE • With optional stainless steel fasteners,cULus Listed to 300 psi/2068 kPa/20.6 bar and FM Approved to the FM ratings shown in the above table.The stainless steel fasteners have a marking designation of"316"on the head of the bolt. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 11 ✓ctsulid victaulic.com 5.5 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DN bar bar 1 1/4—21/2 300 DN32—73.0 mm — 2068 20 1 1/2—21/2 300 EF DN40—73.0 mm 20668 20 300 300 3-4 DN80—DN100 2068 2068 20 20 11/4-2 300 DN32—DN50 2068 Easy Flow 20 3-4 300 DN80—DN100 — 2068 20 11/4-2 300 EL DN32—DN50 — 2068 20 11/a 2 300 300 ET40 DN32—DN50 2068 2068 20 20 11/4-2 300 DN32—DN50 — 2068 EZT 20 11/2-2 300 DN40—DN50 2068 — 20 1 1/2—4 300 300 FF DN40—DN 100 20268 20068 20 11/4-2 300 GL DN32—DN50 — 2068 1 1/4—4 300 300 MF DN32—DN100 20268 2068 20 11/a 2 300 300 MT DN32—DN50 2068 2068 20 20 1 1/4-2 300 300 MLT DN32—DN50 2068 2068 20 20 NOTES • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • Easy Flow=Easy Flow steel pipe manufactured by Borusan Mannesmann • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. Boru. • MLT=MLT steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. . TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. . WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,and WFlow 5 steel pipe • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,WGalweld 7E,and WLight 7 steel pipe • GL=GL steel pipe manufactured by Wheatland Tube Co. manufactured by Wuppermann Stahl GmbH. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctsulid victaulic.com 5.5 PERFORMANCE (CONTINUED) Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DIN bar bar 21/2 —4 300 TF 73.00 mm—DN 100 2068 20 1 1/4-4 300 WG5,WG5E,WF5,WL7 DN32—DIN 100 2068 — 20 1 1/4-4 300 300 WG7,WG7E DN32—DN100 2068 2068 20 20 11/4-2 300 WLS DN32—DN50 — 2068 20 NOTES • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • Easy Flow=Easy Flow steel pipe manufactured by Borusan Mannesmann • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. Boru. • MLT=MLT steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. . TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. . WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,and WFlow 5 steel pipe • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,W1_7=WGalweld 7,WGalweld 7E,and WLight 7 steel pipe • GL=GL steel pipe manufactured by Wheatland Tube Co. manufactured by Wuppermann Stahl GmbH. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctsulid victaulic.com 6.0 NOTIFICATIONS AWARNING _ Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. . Failure to follow these instructions could result in death or serious personal injury 0 and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA)standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. NOTICE • If using coated pipe, always reference the installation instructions for pipe preparation requirements. 7.0 REFERENCE MATERIALS 05.01:Seal Selection Guide 25.01:Original Groove System(OGS)Groove Specifications I-009N:Installation Instructions Firel-ock EZTm Rigid Coupling Style 009N 1-009V:Installation Instructions Firel-ockTm Installation-ReadyTm Rigid Coupling Style 009V 1-100:Victaulic Field Installation Handbook 1-109:Installation Instructions Firel-ockTM One-Bolt Rigid Coupling Style 109 I-ENDCAP:Victaulic End Caps Installation Instructions I-IMPACT:Impact Tool Usage Guidelines User Responsibility for Product Selection and Suitability Intellectual Property Rights Each user bears final responsibility for determining the suitability of Victaulic products No statement concerning the use of any material,product,service,or design is for their end-use application,in accordance with industry standards,project specifica- intended,or should be construed,to grant any license under any patent or other tions,and Victaulic's published performance,maintenance,and safety data,as well intellectual property right of Victaulic or any of its affiliates,or as a recommendation as all warnings and installation instructions.Nothing in this or any other document, for the use of such material,product,service,or design in the infringement of any nor any verbal recommendation,advice,or opinion from any Victaulic employee,shall patent or other intellectual property right.The terms"Patented"or"Patent Pending" be deemed to alter,vary,supersede,or waive any provision of Victaulic Company's refer to design or utility patents or patent applications for articles and/or methods of standard conditions of sale,warranty,installation instructions,or this disclaimer. use in the United States and/or other countries.Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company,and/or its affiliated Installation entities,in the U.S.and/or other countries. Always refer to and follow the Victaulic Installation Handbook or installation instructions for the product you are installing.Handbooks are included with each Note shipment of Victaulic products,providing complete installation and assembly data, All products bearing a Victaulic trademark are manufactured by Victaulic or to and are available in PDF format on our website at victaulic.com. Victaulic specifications.All products are to be installed only in accordance with the applicable Victaulic installation instructions.Victaulic reserves the right to change Warranty product specifications,designs and standard equipment without notice and without Refer to the Warranty section of the current Price List or contact Victaulic for details. incurring obligations. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaulic° Victaulic° FireLockT" Fittings ✓ctaulic° 10.03 0 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4—8"/DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTm Fittings conform to the ratings of Victaulic Fire Lock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS D& <FM > LPCB vdS C E LISTED EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS — MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ❑ Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. 1 �ctaulicr victaulic.com 4.0 DIMENSIONS �CtoE� tC n o E CtoE p p - n �� -0 C T toE J � ele tE � o o No.001 No.003 No.002 No.006 No.001 No.003 No.002 No.006 90'Elbow 45'Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg I mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 11/2 1.900 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic° victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No.002 Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 1/4 1.660 - - - DN32 42.4 - - - - 1 1/2 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN 125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN 150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 - 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctauIii victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling Fire Lock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Fire Lock EZTM Style 009N/009H couplings, use FireLockTm No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64:Victaulic@ FireLockTm Rigid Coupling Style 009N 10.02:Victaulic®FireLockTm Rigid Coupling Style 005H with Vic-PIUSTm Gasket System 29.01:Victaulic@ Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending'refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctauliill Flexible Coupling �� PM �c vds L PCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIP0 STYLE 75 Style 75 is available where moderate pressures are expected or weight _ considerations are a factor. Up to 50%lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500psi/3450kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade"EHP"or"T"gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade"EHP"or"T"gaskets.Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference document 17.09 for pressure ratings and end loads.When used on light wall stainless steel pipe,the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel,refer to document 17.01. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating:Orange enamel. • Optional: Hot dipped galvanized and others. Gasket:(specify choice') • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+860F/+30°C and hot+180°F/+820C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20OF to+180°F/-290C to+820C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. NOTE:Additional gasket styles are available.Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. �otaiullc° REV_N 06.05_1 CARBON STEEL PIPE-GROOVED COUPLINGS 06.05 Flexible Coupling STYLE 75 DIMENSIONS Max.Work All w.Pipe Bolt/Nut@ Approx. Size Pressure Max.End Load Eno Sep.t Deflect.Fr.CLt No-Size Dimensions-Inches/mm Wgt.Each Actual Nominal Outside Size Diameter Pe, Pipe Inches Inches psi Lbs. Cplg In./Ft. i10 a N n1m Deg. mm/M Inches X Y Z kg"q, mm n1m kPa 7 7 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2"-43' 48 2-3/s x 2 61 108 45 0.6 1/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 -10 38 2-3/a x 2 68 117 45 0.6 1 Y2 1.900 500 1420 0-0.06 0.40 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 1 -56 33 2-3/e x 2 74 12 445 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 -31 26 2-'/e x 2 87 133 48 0.8 2 Y2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1°-15' 22 2-3/e x 2 98 144 48 0.9 3.000 500 3535 0-0.06 0.26 4.00 5.90 1.88 1.9 76.1 mm 76.1 3450 15730 0-1.6 1 -12 22 2-3/a x 2 102 150 48 0.9 3 3.500 500 4800 0-0.06 1'-2' 0.22 2-,/5 x 2 3/4 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 3 Y2 4.000 500 6300 0-0.06 0"-54' 0.19 2-1/2 x 2 3/45.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0.13 1'-36' 0.34 2-Y2 x 2 3/4 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 4.250 450 6380 0-0.13 0.35 5.55 7.79 2.13 3.7 108.0 m m 108.0 3100 28395 0-3.2 1 -41' 29 2-12 x 70.0 141 198 54 1.7 4�/2 5.000 450 8820 0-0.13 1°-26' 0.25 2-5/8 x 3'/4 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 21 156 240 54 2.5 5 5.563 450 10935 0-0.13 1°-18' 0.27 2-5/8 x 3 1/46.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 1 256 54 2.6 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 133.0 m m 133.0 3100 43325 0-3.2 1 -21 24 2-16 x 82.5 166 238 54 2.7 139.7 m m 5.500 450 10665 0-0.13 1°-18' 0.28 2-s/e x 3'/4 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 6.000 450 12735 0-0.13 0.21 7.38 10.48 1.88 6.2 152.4 m m 152.4 3100 56670 0-3.2 1 -12 5/e x 3 V4 18 2- 187 266 48 2.8 6 6.625 450 15525 0-0.13 1. 5, 0.23 2-5/8 x 3'/4 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 6.250 450 13800 0-0.13 0.24 7.63 10.49 2.13 6.8 159.0 mm 159.0 3100 61405 0-3.2 1 -9' 20 2-16 x 82.5 194 266 54 3.1 8 8.625 450 26280 0-0.13 0°-50' 0.18 2-3/4 x 4 Ya 10.34 13.97 2.32 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 * Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2720-90 mm;25%for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. �Y � I�Z�I X www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. d%taUliC® 06.05_2 REV_N :..r:�' 1 . 1 Flexible Coupling STYLE 75 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. For complete contact information,visit www.victaulic.com 06.05 1470 REV N UPDATED O1/2013 �Citaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.05 CO® Worldwide www.tyco-fire.com Contacts Model BFV.300/0FV.300C Butterfly Valve Grooved End General Technical Description Data w The TYCO Models BFV-300 and BFV- Approvals 300C Grooved End Butterfly Valves UL and ULC Listed are indicating type valves designed for FM Approved use in fire protection systems where CE Certified a visual indication of open or closed VdS Approved valve condition is required. They are Russian Fire Certificate used, for example, as system, sec- CNPP R1 Listed-APSAD tional and pump water control valves. Listed by California State Fire Marshall They have grooved inlet and outlet con- Refer to Tables A,B and C for applicability. nections that are suitable for use with All laboratory listings and approvals are for grooved end pipe couplings listed or indoor and outdoor use. approved for fire protection systems. For applications requiring supervi- Sizes MODEL BFV-300 sion of the open or closed state of the 2-12 Inch(DN50-DN300) WITH OPEN SUPERVISORY valve,the Gear Operators for the Model UL/ULC/FM Maximum Working SWITCHES BFV-300/BFV-300C Butterfly Valves Pressure feature two sets of factory installed 2-8 Inch(DN50-DN200).... 300 psi(20,7 bar) internal switches each having SPDT 10-12 Inch(DN250-DN300)..175 psi(12,1 bar) , contacts (Ref. Figure 3). The super- VdS Maximum Working Pressure visory switches transfer their electri- 2-8 Inch(DN50-DN200).... 300 psi(20,7 bar) cal contacts when there is movement 10 Inch(DN250) ........... 232 psi(16,0 bar) from the open or closed disc position 12 Inch(DN300) ............175 psi(12,1 bar) during the first two revolutions of the Maximum Working Temperature handwheel. 212°F(100`C)in accordance with UL 1091 Materials of Construction / Body.........................Ductile Iron The Model BFV-300/BFV-300C Body Coating ........... RILSAN PA11 Black Grooved End Butterfly Valves described Disc..........................Ductile Iron herein must be installed and maintained Disc Seal.Lower Stem Encapsulated Upper&Lower Stem.......... Stainless Steel in compliance with this document, as Handwheel ....................Ductile Iron well as with the applicable standards (BFV-300 red painted;BFV-300C black painted) of the National Fire Protection Asso- Actuator,2-6 Inch(DN50-DN150): ciation, in addition to the standards Of • IP 65, bronze traveling nut gearbox, ductile MODEL BFV-300C an other having jurisdiction. iron housing WITH CLOSED SUPERVISORY y gl Actuator,8-12 Inch(DN200-DN300): SWITCHES Failure to do so may impair the perfor- • IP 65,brass segmented gearbox,ductile iron mance of these devices. housing The owner is responsible for main- Silicone Free Model Availability ST, taining their fire protection system Silicone free models are available.Contact and devices in proper operating con- Tyco sales for information. dition. Contact the installing contrac- Tapping Bosses "9� g toe or product manufacturer with any Two factory-plugged NPT threaded tapping ERE questions. bosses in the valve body are located on the C E up- and downstream sides of the disc for connection to valve trim. Tapping boss CP sizes: <@> 2-3 inch(DN50-DN80).............3/8 NPT 4-12 inch(DN100-DN300)..........1/2 NPT APPROVED Control Valve Seat Leakage Class IEC 60534-4 CLASS VI(Type C)Control Valve Seat Leakage according to ANSI/FCI 70-2-2006(ASME B16.104) Page 1 of 8 JANUARY 2018 TFP1511 TFP1511 Page 2 of 8 Pipe Nominal Dimensions Nominal P Valve Size ip Inches Weight (mm) Lbs. Inches Inches (kg) (DN) (mm) A B C D E F G H J 2 2.37 3.8 10.63 2.85 4.90 4.92 4.28 1.99 10.8 DN50 60,3 96,4 270 72,5 124,5 125 108,E 50,5 0 0 4,9 2-1/2 2.88 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 DN65 73,0 96,4 297,8 85 139,8 125 108,E (50,5) 0 0 5,9 3 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 DN65 76,1 96,4 297,8 85 139,8 125 108,E (50,5) 0 0 5,9 3 3.5 3.8 12.22 3.58 5.76 4.92 4.28 1.99 13.9 DN80 88,9 96,4 310,3 91 146,3 125 108,E 50,5 0 0 6,3 4 4.5 4.54 13.92 4.29 6.75 4.92 4.28 1.99 17.64 DN100 114,3 115,4 353,5 109 171,5 125 108,E 50,5 0 0 8,0 5.5 5.83 16 5.16 7.93 5.91 5.79 2.32 26.4 DN125 139,7 148 406,E 131 201,5 150 147 (58,9) 0 0 11,9 5 5.56 5.83 16 5.16 7.93 5.91 5.79 2.32 26.4 DN125 141,3 148 406,E 131 201,5 150 147 58,9 0 0 11,9 6.5 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN150 165,1 148 433,E 145 214,5 150 147 (58,9) 0 0 13,8 6 6.63 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN150 168,3 148 433,E 145 214,5 150 147 (58,9) 0 0 13,8 8 8.63 5.24 19.67 6.69 9.29 8.86 8.19 2.76 5.66 1.24 47.18 DN200 219,1 133 499,5 170 236 225 208 70 143,7 31,4 21,4 10 10.75 6.26 22.46 7.68 11.1 11.14 8.19 2.91 7.21 1.65 73.41 DN250 273 159 570,5 195 282 283 208 74 183,1 41,8 33,3 12 12.75 6.5 25.39 9.5 12.2 11.14 8.19 2.91 9.96 2.7 89.29 DN300 323,9 165 645 241,5 310 283 208 74 252,9 68,5 40,5 SEGMENTED HANDWHEEL GEAR OPERATOR 8 TO 12 INCH E INDICATOR (DN200 TO DN300) FLAG VALVE SIZES T CD - (VALVE CLOSED)---h qq= F TAPPING O O G BOSSES B IuIi�V HANDWHEEL INDICATOR HANDWHEEL BODY FLAG (VALVE TAPPING 0 0 OPEN) 0 BOSSES----- n A o (pn' 1 o TAPPING 1 BOSSES � \ DISC J H TRAVELLING NUT TRAVELLING NUT ELECTRICAL CONNECTOR GEAR OPERATOR GEAR OPERATOR 2 TO 4 INCH 5 TO 6 INCH (DN50 TO DN100) (DN125 TO DN150) VALVE SIZES VALVE SIZES FIGURE 1 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS FP1511 Page 3of8 No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. ASTM ASTM ASTM 01 Body A-536 1 15 Spring Pin A-228 1 30 Bolt(Round) A-167 3 02 Upper Stem AISI 410 1 16 Indicator AST 1 31 Plate Washer AS16M 4 03 Lower Stem AISI 410 1 17 O-Ring NBR 1 32 Switch Assembly — 1 04 Disc EPDM 1 18 Cover Gasket Paper 1 33 T/R Bolt ASTM 2 A-307 05 O-Ring(P12) EPDM 4 19 Spring Pin ASTM 1 34 Tapping Screw S10C 1 05x1Tx25 A-228 ST3.5 x 7.5 06 Oiless B/R — 4 20 O-Ring(P10) EPDM 1 35 Tooth Washer 4# S10C 1 MB1410 07 2-E2-4 Inpch EPDM 1 21 Worm Shaft AISI 410 1 36 Lever ASTM 1 08 Gear Box ASTM 1 22 Bushing(1) FD-0205-45 1 37 Connector — 1 A-536 Traveling Nut Bronze 1 23 Collar FD-0205-45 1 38 Sticker — 1 09 2-6 Inch Segment Gear C3604BD 1 24 Spring Washer ASTM 4 39 Sticker — 1 8-12 Inch A-167 10 Bushing(2) FD-0205-45 1 25 Hex Bolt ASTM 2 40 Spring Pin ASTM 1 M8 x 20L A-167 03x0.6Tx25 A-228 11 Cover ASTM 1 26 Hex Bolt ASTM 2 Headless Plug A-619 M8 x 25L A-167 3/8 NPT 12 Bushing Fe 1 27 Gasket Paper 1 41 2-3 Inch ASTM 2 Headless Wrench ASTM Spring Pin ASTM A-307 13 Bolt M5 x 7L A-307 1 28 04x0.8tx25 A-228 1 Headless Plug ASTM 1/2 NPT A 14 Stem Housing Fe 1 29 Handwheel ASTM 1 4-12 Inch 35 34 37 33 30 37 33 35 36 \ 30 32 / 34 32 36 O o 38,39 a 38,39 28 31 28 ----------- 31 30 30 19, 19, 29 20 40 17 14 12 18 29 20 40 17 14 12 18 16 16 —------------- 11 11 15 / 15 -_—- 21 10 21 10 13 13 22 09 22 09 27 27 -- 23 08 23 08 25 25 24 05 24 05 26 26 25 02 25 02 01 41 01 41 04 — 03 04 03 06 -07 06 07 BFV-300 Normally Open Valve BFV-300C Normally Closed Valve Supervisory Switch Arrangement Supervisory Switch Arrangement FIGURE 2 MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE ASSEMBLY TFP1511 Page 4of8 FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 200 400 600 1000 2000 4000 6000 10000 20000 9.0 0,60 8.0 7.0 0,50 6.0 0,40 5.0 �yo� 0,30 4.0 O � m _ Q a = 2.0 = 0 ti 0,20 z oz o w 0m w =U =w cr 2.0 ^ ^pp o w00 w � ti Z� `O= ti o (L M Z =� 010 w � w a =V �yo 0,09cr z o o V� Q2 0,08 aJ a OD 1.0 007 zv z 0- 0.9 2� 0 0,06 0 z 0.8 CO 0 0.7 Q=� �cL o 0,05 z 0.6 V� S =�0 0,04 0.5 =U cb `O ,moo V� 0,03 0.4 �N 0.3 50 60 80 100 200 400 600 800 1000 2000 4000 6000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW YELLOW F------- YELLOW i S-1 FIRE ALARM COMMON(WHITE) COMMON(WHITE) END OF LINE CONTROL PANEL RESISTOR SUPERVISORY RED RED OR CIRCUIT NEXT DEVICE MODEL BFV-300/BFV-300C I GREEN GEAR OPERATOR OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC I I BLUE 5A 24VDC SWITCH S-1,2 LEADS PER CONTACT SWITCH S-2, 1 LEAD PER CONTACT i S-2 COMMON(BLACK) I I ORANGE VOLTAGE L_____J AUX. DEVICE SOURCE ____ ____ (BELL OR HORN) FIGURE 3 MODEL BFV-300 BUTTERFLY VALVE OPEN POSITION—SUPERVISORY SWITCH OPEN POSITION MODEL BFV-300C BUTTERFLY VALVE CLOSED POSITION—SUPERVISORY SWITCH CLOSED POSITION INTERNAL SWITCH WIRING DIAGRAM FP1511 Page 5of8 Nominal Pipe Part Number A enc Listing/Approval Valve Size O.D. Max. BFV-300 BFV-300C CA Fire Russian Inches Inches (bar) Supv.Switch Supv.Switch CIE UL ULC FM VdS Marshall CNPP PAVUS Fire (DN) (mm) OPEN CLOSED Cert. 2 2.38 300 5930OG02OWS 5930OG02OWSC ✓ ✓ ✓ ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25WS 59300GO25WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 73,0 20,7 3 300 59300GO26WS 59300GO26WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 76,1 20,7 3 3,5 300 5930OG03OWS 5930OG03OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 5930OG04OWS 5930OG04OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300GO56WS 59300GO56WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 5930OG05OWS 5930OG05OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66WS 59300GO66WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 5930OG06OWS 5930OG06OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 5930OG08OWS 5930OG08OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG10OWS 5930OG10OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG12OWS 5930OG12OWSC ✓ ✓ ✓ ✓ ✓ ✓ DN300 323,9 12,1 TABLE A MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Pipe Part Number Agency Listing roval Valve Size O.D. Max. BFV-300 BFV-300C Inches Inches (bar) Supv.Switch Supv.Switch CIE VdS CNPP (DN) (mm) OPEN CLOSED 2 2.38 300 59300GO20AWS 59300GO20AWSC ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25AWS 59300GO25AWSC ✓ ✓ ✓ DN65 73,0 20,7 3 300 DN65 76,1 20,759300G026AWS 59300GO26AWSC ✓ ✓ ✓ 3 3,5 300 59300GO30AWS 59300GO30AWSC ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 59300GO40AWS 59300GO40AWSC ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300GO56AWS 59300GO56AWSC ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 59300GO50AWS 59300GO50AWSC ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66AWS 59300GO66AWSC ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 59300GO60AWS 59300GO60AWSC ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 59300GO80AWS 59300GO80AWSC ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG100AWS 5930OG100AWSC ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG120AWS 5930OG120AWSC ✓ ✓ ✓ DN300 323,9 12,1 TABLE B MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE WITH CNPP-APSAD LARGE 100 X 100 MM FLAG AND INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS TFP1511 Page 6 of 8 Nominal Pipe enc Listin /A roval Max.. Valve Size O.D. Part Russian Inches Inches (bar) Number CE UL ULC FM VdS CA Fire Marshall CNPP PAVUS Fire (DN) (mm) Cert. 2 2.38 300 5930OG02ONS ✓ ✓ ✓ ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 73,0 20,7 3 300 59300GO26NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 76,1 20,7 3 3,5 300 5930OG03ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 5930OG04ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300G056NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 5930OG05ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 5930OG06ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 5930OG08ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG10ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG12ONS ✓ ✓ ✓ ✓ ✓ ✓ DN300 323,9 12,1 TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Part Number Nominal Bernstein Operator Valve Size Gear Mounting Bernstein Bernstein GC-SU1Z Inches Type Bracket with i88-IP i88-IP65 65 LED Switch Ex IP-66/67 ATEX (DN) Mounting Bolts Regular Switch 24V (Ex 112G Ex dlIC T6 Gb) Switch 2-4 59300SPBRACKET10 (DN50-DN100) Travelling 5-6 Nut 59300SPBRACKET20 DN125-DN200 59300SPSW 59300SPSWLED 59300SPSWATEX 8 59300SPBRACKET25 DN200 Segmented 10-12 Gear 59300SPBRACKET30 DN250-DN300 Notes: 1. Install a single switch in either bracket mounting position to monitor Open or Closed valve condition r--- —� a I I ® Bernstein Switch Wiring Diagram TABLE D MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES ACCESSORY EXTERNAL SUPERVISORY SWITCHES AND MOUNTING BRACKETS PART NUMBER SELECTION FP1511 Page 7 of 8 Installation Nominal Valve Size Part Number Inches BFV-300,Red Painted BFV-300C,Black Painted The Model BFV-300/BFV-300C (DN) Grooved End Butterfly Valves may be 2-4 59300SPHWHEELIO 59300SPHWHEELIOB installed with flow in either direction DN50-DN100 and can be positioned either horizon- 5-8 59300SPHWHEEL20 59300SPHWHEEL20B tally or vertically. DN125-DN200 10-12 59300SPHWHEEL30 59300SPHWHEEL30B The grooved end pipe couplings DN250-DN300 used with the Model BFV-300/BFV- TABLE E 300C must be listed or approved for BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE fire protection service and installed in REPLACEMENT HANDWHEEL accordance with the manufacturers PART NUMBER SELECTION instructions. The Model BFV-300/BFV-300C But- Limited Accessories terfly Valve may be installed with any schedule of pressure class of pipe or External Supervisory Switch and tubing that is listed or approved for fire Warranty Mounting Bracket protection. For warranty terms and conditions,visit Note: Accessory external supervi- Conduit and electrical connections www.tyco-fire.com. sory switches and mounting brackets are to be made in accordance with are applicable only to valves without the authority having jurisdiction and/ Ordering factory-installed internal supervisory or the National Electrical Code. With switches. reference to Figure 3, the supervisory procedure Refer to Table D for switch models and switch is intended for connection to part numbers. the supervisory circuit of a fire alarm Contact your local distributor for avail- control panel in accordance with NFPA ability.When placing an order, indicate Specify: (specify size) Model BFV-300 72.The auxiliary switch is intended for the full product name and Part Number Grooved End Butterfly Valve Exter- the unsupervised connection to aux- (P/N). nal Switch Mounting Bracket, P/N iliary equipment in accordance with (specify), with (specify quantity) Bern- NFPA 70, National Electric Code. Butterfly Valves stein External Switch (specify model), NOTE: For outdoor applications with Model BFV-300 with Internal P/N (specify) internal supervisory switches, it is rec- Open Supervisory Switches Replacement Parts ommended that wiring connections Specify: (specify size) Model BFV-300 Note: Only items described in this be made at a temperature above 15°F Grooved End Butterfly Valve, Inter- section are offered as replacement (-9°C),in order to insure sufficient flex- nal Open Supervisory Switches, parts. ibility of the wire lead insulation. P/N (specify per Table A) Handwheel Model BFV-300C with Internal Replacement handwheel includes pin. Care and Closed Supervisory Switches Refer to Table E for part numbers. Maintenance Specify: (specify size) Model BFV- Model BFV-300 Red Painted 300C Grooved End Butterfly Valve, Before closing a fire protection system Internal Closed Supervisory Switches, Specify: Handwheel, (specify size) control valve for maintenance or P/N (specify per Table A) Model BFV-300 Grooved End Butter- inspection work on either the valve or Model BFV-300 with Internal fly Valve, P/N (specify) fire protection system which it con- Open Supervisory Switches, Model BFV-300C, Black Painted trols, permission to shut down the APSAD Approved Specify: Handwheel, (specify size) affected fire protection systems must Specify: (specify size) Model BFV-300 Model BFV-300C Grooved End But- be obtained from the proper authorities Grooved End Butterfly Valve, Internal terfly Valve, P/N (specify) and all personnel who may be affected Open Supervisory Switches, APSAD by this decision must be notified. Approved, P/N(specify per Table B) The owner is responsible for the Model BFV-300C with Internal inspection,testing,and maintenance of Closed Supervisory Switches, their fire protection system and devices APSAD Approved in accordance with the applicable stan- Specify: (specify size) Model dards of the National Fire Protection BFV-300C Grooved End Butter- Association(e.g., NFPA 25), in addition fly Valve, Internal Closed Supervi- to the standards of any authority having sory Switches, APSAD Approved, jurisdiction.Contact the installing con- P/N (specify per Table B) tractor or product manufacturer with any questions. Any impairment must Model BFV-300 without Internal be immediately corrected. Supervisory Switches It is recommended that automatic Specify: (specify size) Model BFV-300 sprinkler systems be inspected,tested, Grooved End Butterfly Valve, and maintained by a qualified inspec- tion service. TFP1511 Page 8of8 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson I nson ORO RILSAN Is a registered trademark of Ark,,,,Inc. Controls tqCOWorldwide Fire Protection Contacts www.tyco-fire.com Products Model CV-1F Grooved End Swing Check Valves The owner is responsible for main- General taining their fire protection system Descr►nt�On and devices in proper operating con- M dition. Contact the installing contrac- The TYCO Model CV-1 F Grooved End for or product manufacturer with any Swing Check Valves are compact questions. and rugged swing-type units that allow water flow in one direction and Technical prevent flow in the opposite direction. _ A resilient elastomer seal facing on the Data spring-loaded clapper ensures a leak- k; tight seal and non-sticking operation. Approvals The Model CV-1 F Check Valves are Compliance with CE Pressure designed to minimize water hammer Equipment Directive(PED)and caused by flow reversal. Standards of Engineering Practice The Model CV-1 F Grooved End Swing • 2 to 12 Inch (DN50 to DN300): u` C FM Check Valves are furnished with UL and C-UL Listed, FM Approved, grooved ends and can be installed Bureau Veritas APPROVED using GRINNELL Grooved Couplings °F9 or GRINNELL Figure 71 Flange Adapt- VdS to Inch (DN65 to DN250): �+ ers. The Model CV-1F Check Valves dSApproved Vds have been designed with a removable Certificate No. G4060018 ,azs cover for ease of field maintenance. Sizes For fire protection pressure rating, These valves can be installed horizon- 2 to 12 Inch(DN50 to DN300) listing and approval information,contact tally(with cover in the upward position) your TYCO representative. or vertically with the flow in the upward Maximum Working Pressure direction(Ref. Figure 3). UL/FM -300 psi (20,7 bar) Installation VdS- 16 bar A check valve maintenance kit is avail- Valve Assembly Finish The Model CV-1 F Grooved End Swing able to allow backflushing through a Red, non-lead paint Check Valves are to be installed in fire department connection without accordance with this section: removing the Model CV-1F Grooved End Swing Check Valve from the riser. Step 1. The arrow cast on the body Refer to technical data sheet TFP1555. must point in the direction of the flow. Model CV-1F is a re-designation for Step 2. Valves installed vertically Central Figure 590F and GRINNELL must be positioned with the flow in the Figure 590F Grooved End Swing Check upward direction. Valves. Step 3. Valves installed horizontally must be positioned with the cover EEM facing up(Ref. Figure 3). The TYCO Model CV-1F Grooved End Step 4. Grooved end pipe couplings Swing Check Valves described herein used with the Model CV-1 F Grooved must be installed and maintained in End Swing Check Valves must be compliance with this document and installed in accordance with manufac- with the applicable standards of the turer's instructions. National Fire Protection Association (NFPA), in addition to the standards Note:Valves should be installed a rea- of any authorities having jurisdiction. sonable distance downstream from Failure to do so may impair the perfor- pumps, elbows, expanders, reducers, mance of these devices. or other similar devices to extend the piping component valve life.Standard piping practices call Never remove any pip nor correct or modify in in den for a minimum of five(5)times the pipe y y piping g diameter for general use. ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 6 FEBRUARY 2016 TFP1550 TFP1550 Page 2 of 6 Nominal Dimensions Nominal Pipe Size Inch Cover Approx. (mm) Bolt Weight Valve Size Pipe O.D. Torque Lbs.Lbs.-ft. (kg) Inch Inch A B C D E F J (Nm) (DN) (mm) 2 2.37 6.75 1.96 1.96 2.57 3.25 4.75 1.62 18 9.0 (50) (60,3) (171,5) (49,8) (49,8) (65,3) (82,3) (120,7) (41,5) (25) (4,5) 2-1/2 2.88 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (73,0) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 76,1 mm 3.00 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (76,1) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 3 3.50 8.37 5.72 2.81 3.31 3.87 5.87 1.63 39 11.0 (80) (88,9) (212,6) (145,3) (71,4) (84,1) (98,3) (149,1) (41,7) (54) (5,0) 4 4.50 9.63 6.68 3.80 3.63 4.53 7.13 1.84 50 25.0 (100) (114,3) (244,6) (169,7) (96,5) (92,2) (115,4) (181,1) (46,7) (69) (11,3) 1397 mm 5.50 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (139,7) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 5 5.56 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (141,3) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 165,1 mm 6.50 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 (150) (165,1) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 6 6.63 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 (150) (168,3) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 8 8.63 14.00 10.14 6.67 5.52 5.46 8.46 2.13 120 66.0 (200) (219,1) (355,6) (257,8) (169,4) (140,2) (138,7) (214,9) (54,1) (164) (29,9) 10 10.75 18.00 12.38 8.62 6.41 7.50 10.50 3.00 130 109.7 (250) (273,1) (457,2) (314,5) (218,9) (162,8) (190,5) (266,7) (76,2) (178) (49,4) 12 12.75 21.00 14.28 9.93 7.27 7.62 10.62 2.75 130 151.0 (300) (323,9) (533,4) (362,7) (252,2) (184,7) (193,5) (269,7) (69,9) (178) (68,0) B - A C O ♦ O.D. D 1 1 1/2" NPT 1/2" J NPT — E F - FIGURE 1 MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL DIMENSIONS Care and system from the proper authorities of the National Fire Protection Associa- and notify all personnel who may be tion (e.g., NFPA 25), in addition to the Maintenance affected by this decision. standards of any authority having juris- After placing a fire protection system diction. Contact the installing contrac- The TYCO Model CV-1 F Grooved End in service, notify the proper authorities for or product manufacturer with any Swing Check Valves must be main- and advise those responsible for moni- questions. Any impairments must be tained and serviced in accordance with toring proprietary and/or central station immediately corrected. this section. alarms. Automatic sprinkler systems are rec- Before closing a fire protection system The owner is responsible for the ommended to be inspected, tested, main control valve for maintenance inspection,testing,and maintenance of and maintained by a qualified Inspec- work on the fire protection system their fire protection system and devices tion Service in accordance with local that it controls, obtain permission to in compliance with this document, as requirements and/or national codes. shut down the affected fire protection well as with the applicable standards TFP155O Page 3 of 6 No. Part Material Oty. No. Part Material Oty. No. Part Material Oty. 1 Body Ductile Iron 1 6 Clapper Facing EPDM Grade"E 1 14 Locknut Steel Stainless 1 " 2 Cover Ductile Iron 1 7 Spring Stainless 1 15 Plug Cast Iron 2 Steel 1/2" NPT 3 Cover Gasket Nitrite 1 8 Hinge Shaft Stainless 1 16 Adhesive Thread AR Rubber Steel Sealer 4 Hex Cap Screw Steel, AR 9 Retaining Ring Stainless AR 17 Nameplate Aluminum 1 Zinc Plated Steel Clapper,2"-8" Stainless 11 Retention Bolt Stainless 1 18 Rivet Steel 2 5 (DN50-200) Steel 1 Steel Clapper,10"-12" Ductile Iron 13 Retaining Disc Stainless 1 19 Spacer Stainless 1 (DN250-300) Steel Steel 8 8 4,16 18 17 't�9 5 2 SEE 9 2 7 3 VIEW A 2" -8" 2 10"-12" 7 5 (DN50-DN200) (DN250-DN300) VIEW A 13 D SEE 5 13 �11,16 DETAIL B 11 1 14,16 I / 6 / 19 5 6 1 15 2"-8" 10"-12" (DN50-DN200) (DN250-DN300) DETAIL B FIGURE 2 MODEL CV-1F GROOVED END SWING CHECK VALVES ASSEMBLY FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 4.0 �o o� 0,30 = O= o Z IL Q 3.0 =VZ =U0,20 z o z `V 2V� =^rye �� a Cr LU Z CV 0 Ir CC 2.0 2V WA `O= o� Cr `� aLo w coo W C3 V O h oC co Ir = Z 2�' o� 0,10 U)o IL w co =V O = 0,09 EL w u z U) o C 0,08 a s g 0 1.0 = 2U 0,07 T Oz O 0.8 �o ".`y 0 06 z 0.7 0,05 o44t:1 1 in z woo All 0.6 0,04 0.5 12 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL PRESSURE LOSS VS. FLOW TFP1550 Page 4of6 Valve Size Pipe O.D. Inch Inch Part Number (DN) (mm) 2 2.37 59-590-0-020 (50) (60,3) 2-1/2 2.88 59-590-0-025 (65) (73,0) 76,1 mm 3.00 59-590-0-076 (65) (76,1) 3 3.50 59-590-0-030 (80) (88,9) 4 4.50 59-590-0-040 (100) (114,3) 139,7 mm 5.50 59-590-0-139 (125) (139,7) 5 5.56 59-590-0-050 (125) (141,3) 165,1 mm 6.50 59-590-0-165 (150) (165,1) 6 6.63 59-590-0-060 (150) (168,3) 8 8.63 59-590-0-080 (200) (219,1) 10 10.75 59-590-0-100 (250) (273,1) 12 12.75 59-590-0-120 (300) (323,9) TABLE A MODEL CV-1F GROOVED END SWING CHECK VALVES PART NUMBER SELECTION Valve Size Pipe O.D. Cover Gasket Part Number Clapper Facing Part Number Clapper Assembly Part Number Inch Inch (DN) (mm) Americas Only EMEA/APAC Americas Only EMEA/APAC Americas Only EMEA/APAC 2 2.37 595907020 97670501 59020EPDM 59020EPDM 97670201A 97670201 (50) (60,3) 2-1/2 2-88 595907030 97561801 59025EPDME 59025EPDM 97562801A 97562065 (65) (73,0) 76,1 mm 3.00 595907030 97561801 59025EPDME 59025EPDM — 97562801 (65) (76,1) 3 3.50 595907030 97561801 59030EPDME 59030EPDM 97562201A 97562201 (80) (88,9) (100) (44g) 595907040 97512001 59040EPDME 59040EPDM 97549001A 97549001 139,7 mm 5.50 595907040 97512001 59050EPDME 59050EPDM — 97565501 (125) (139,7) 5 5.56 595907040 97512001 59050EPDME 59050EPDM 97565501A 97562125 (125) (141,3) 165,1 mm 6.50 595907060 97521801 59060EPDME 59060EPDM — 97524101 (150) (165,1) 6 6.63 595907060 97521801 59060EPDME 59060EPDM 97524101A 97562150 (150) (168,3) (200) (2191) 595907080 97547901 59080EPDME 59080EPDM 97592201A 97592201 10 10.75 595907100 97600001 59100EPDM 59100EPDM 97598001A 97598001 (250) (273,1) 12 12.75 595907120 97600002 59120EPDM 59120EPDM 97647701A 97647701 (300) (323,9) TABLE B MODEL CV-1 F GROOVED END SWING CHECK VALVES REPLACEMENT VALVE PARTS PART NUMBER SELECTION TFP1550 Page 5of6 OUTLET Limited Ordering I� Warranty Procedure J 0 3: For warranty terms and conditions,visit Contact your local distributor for avail- COVER o www.tyco-fire.com. ability.When placing an order, indicate LL the full product name and Part Number (P/N). Model CV-1 IF Check Valve INLET Specify: Model CV-11F Grooved End VERTICAL ORIENTATION Swing Check Valve, size (specify), P/N (specify per Table A) COVER FLOW Replacement Valve Parts Refer to Figure 2 to identify Parts. Cover Gasket Specify: Model CV-1F Grooved End INLET O OUTLET Swing Check Valve,Cover Gasket,size (specify), P/N (specify per Table B) Clapper Facing HORIZONTAL ORIENTATION Specify: Model CV-1F Grooved End FIGURE 3 Swing Check Valve, Clapper Seal MODEL CV-1F GROOVED END Facing, EPDM Grade"E",size(specify), SWING CHECK VALVES P/N (specify per Table B) PROPER ORIENTATION Clapper Assembly Includes items 2, 3, 5-14, and 17-19. Specify: Model CV-11F Grooved End Swing Check Valve,Clapper Assembly, size(specify), P/N(specify per Table B) TFP155O Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tgg0 Fire Protection Products GL • E 4077 Airpark Dr. Standish, MI 48658 .989-846-4583•www.globesprinkler.com Technical Support•989 414 2600•techservice@globesprinkler.com MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY (With or Without Control Valve) 1%", 2", 2%", 76.1mm, 3", 4", 6", 165.1mm, 8" GENERAL DESCRIPTION The Globe Series "UMC' Universal Manifold Check is a first of its kind, UL Listed and FM Approved, complete floor control station or shotgun riser assembly. It is pressure rated for 300 psi (20,6 bar). It provides the most compact "footprint"while delivering all of the necessary components o for your floor control station as required by the NFPA Stan- dards. With its multiple available configurations, it allows the contractor to order the suitable configuration for the site specific needs. The "UMC' Universal Manifold Check is more than just a traditional stand-alone manifold. It serves as a complete floor control station as well as a complete shotgun riser assembly inclusive of Control Valve with In- ternal Supervisory Switch; Check Valve; Flow Switch; Test MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY and Drain Assembly; Adjustable Pressure Relief Valve As- sembly pre-piped to drain; supply gauge (4", 6"and 8")and system gauge (1 1/4" through 8"). The "UMC' Universal Manifold Check replaces the need to order individual "Riser SHOTGUN RISER ASSEMBLY Manifolds" plus control valves, check valves, and relief "Shotgun Riser Assemblies" are those assemblies which valve kits as all of these components are integrated into are typically installed in vertical orientations on individual the one compact design, saving space as well as the labor system Risers. The Globe "Shotgun" Riser Manifold As- to connect these separate components. For sizes 3" and sembly is available in 4 inch (DN 100), 6 inch (DN 150), smaller, an 18" long stainless steel braided flexible hose is and 8 inch (DN 200) sizes and is equipped with a control included with the UMC for connecting the Test and Drain valve; check valve; flow switch; test and drain valve with valve to a drain stack. The design takes into account both NFPA required pressure relief valve; 2 gauges (system and "left-hand" and "right-hand" orientations. (8" version avail- supply). Sizes 4 inch (DN 100), 6 inch (DN 150), and 8 inch able preassembled in right-hand orientation only) (DN 200) are equipped with a pressure gauge on both sys- tem side and supply side of the check valve clapper. The 8" UMC consists of a Universal Manifold, a Victaulic Series The UMC may be utilized to meet the NFPA 13 require- 717 Grooved Check Valve and an optional Victaulic Series ments for Floor Control Valve Assemblies where there are 705 Grooved Butterfly Valve. multistory buildings exceeding two stories in height requir- ing zoning by floor or whenever separate control and floor zoning is specified. The UMC has been engineered with space savings in mind for those commonly installed appli- TECHNICAL DATA cations in stairwell landings and small alcoves. All UMC Approvals assemblies include the NFPA 13 required Listed Pressure PP Relief Valve which is pre-piped to drain. The relief valve is • cULus preset for 175 psi and is adjustable to 310 psi for high pres- • FM sure system conditions. In addition to the relief valve, the Maximum System Working Pressure UMC is equipped with a Test and Drain Valve.The Test and • 300 psi (20.6 Bar) Drain Valve contains a test orifice of K2.8, K4.2 and K5.6 for 1", 1 1/4" and 2" respectively so that it may be utilized End Connections for flow testing any system with sprinklers having K-Factors • See Table A of that size or larger. Materials of Construction Note:NFPA 13 requires that a test connection providing a flow rate equal to or See Figure 1 less than one sprinkler of a type having the smallest orifice on the system is to be provided. A pressure gauge is provided above the check valve clap- *Multiple Patents Pending per for sizes 1'/4" through 3" to meet the gauge require- ment per NFPA 13 for Floor Control Assemblies. Typically the supply side gauge is not required for multistory build- ings with floor control stations as a system gauge would be on the main feed/riser but all Model UMC Manifold Check Valves are equipped with a 1/4" (DN 8) port below the clap- per to accommodate a second gauge if desired. AUG 2021 GFV-120 Page 1 of 14 A I 6 6 1 12 1 12 11 8 21 a9 2 9 2 15 10 14 6 0 19 3 7 18 16 17 I o fi 20 4 3 O O 13 4 aei 0 5 5 j 5 SECTION A-A I A SIDE VIEW FRONT VIEW ITEM DESCRIPTION I . MATERIAL NO. 1 I UMC VALVE BODY I DUCTILE IRON 2 RECESSED HEX PLUG I STAINLESS STEEL 3 I FLOW SWITCH I SEE FLOW SWITCH TECHNICAL LITERATURE 4 I RIGID COUPLING I SEE COUPLING TECHNICAL LITERATURE 5 BUTTERFLY CONTROL VALVE SEE GLOBE BUTTERFLY CONTROL VALVE TECHNICAL LITERATURE WITH INTERNAL SUPERVISORY SWITCH 6 PRESSURE GAUGE PLASTIC 7 THREEWAY VALVE BRONZE 8 UMC COVER PLATE DUCTILE IRON 9 BOLT STAINLESS STEEL 10 FLOW SWITCH ADAPTER DUCTILE IRON 11 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570 12 MODEL ARV ADJUSTABLE RELIEF VALVE SEE VICTAULIC SUBMITTAL 30.74 13 FLOW SWITCH PLUG DUCTILE IRON 14 UMC VALVE CLAPPER STAINLESS STEEL 15 UMC VALVE CLAPPER RETAINING BOLT STAINLESS STEEL 16 UMC VALVE CLAPPER RETAINING NUT STAINLESS STEEL 17 UMC VALVE HINGE PIN STAINLESS STEEL 18 CLAPPER FACING RETAINING RING STAINLESS STEEL 19 CLAPPER FACING EDPM 20 FLOW SWITCH PLUG BOLT STAINLESS STEEL 21 CLAPPER SPRING STAINLESS STEEL NOTE: •4"(DN100)shown as reference See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations Flow switch rotated 90 degrees on 1-1/4"through 2 1/2"sizes FIGURE 1 : MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION (1 1/4„ - 6") AUG 2021 GFV-120 Page 2 of 14 s s 1 7 1 9 7 o s a / i a O O 4 2 2 0 5 DSO o O 5 5 FRONT VIEW SIDE VIEW ITEM NO. DESCRIPTION Ilff MATERIAL 1 UM VALVE BODY DUCTILE IRON 2 SERIES 717 CHECK VALVE DUCTILE IRON BODY SEE VICTAULIC SUBMITTAL 10.08 3 FLOW SWITCH SEE FLOW SWITCH TECHNICAL LITERATURE 4 RIGID COUPLING SEE COUPLING TECHNICAL LITERATURE 5 BUTTERFLY CONTROL VALVE SEE VICTAULIC SUBMITTAL 10.81 WITH INTERNAL SUPERVISORY SWITCH 6 PRESSURE GAUGE PLASTIC 7 3-WAY SOG VALVE BRONZE 8 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570 9 MODELARV ADJUSTABLE RELIEF VALVE SEE VICTAULIC SUBMITTAL 30.74 NOTE: •See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations FIGURE 2: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION (811) AUG 2021 GFV-120 Page 3 of 14 MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY LEFT HANDED VS RIGHT HANDED Both the shotgun riser assembly and the floor control tion of the Model UTD Test and Drain determines the station assembly are available as left handed or right "Hand" of the valve. If the Model UTD Test and Drain handed assembly. The determining factor of the left is connected to the port on the right side of the valve handed vs right handed is the position of the Model body, it is considered a right handed assembly. If the UTD Test and Drain. While looking at the faceplate Model UTD Test and Drain is connected to the port on with the Model UMC valve in the vertical orientation the left side of the Model UMC valve the assembly is and flow upward (shotgun riser orientation), the posi- considered left handed. TEST AND DRAIN TEST AND DRAIN ASSEMBLY • UMC BODY ASSEMBLY b MIRRORED PORTS FOR H ALTERNATE TEST AND DRAIN LOCATIONS g o 0 FLOW SWITCH o o I NOTE:SUPPLY GAUGE """ NOTE:SUPPLY GAUGE NOT INCLUDED ON 3" 0 NOT INCLUDED ON 3" ASSEMBLY area ASSEMBLY ova 0 0 ®� BUTTERFLY VALVE FLOW FLOW LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY CONFIGURATION REPRESENTATIVE OF SIZES 3"THROUGH 6" MIRRORED FLOW SWITCH FLOW SWITCH MIRRORED PORT BUTTERFLY VALVE / PORT �LOW� ® ® I � f� B- e - O ® 4y e UMC BODY UMC BODY € 'mm b a o TEST AND DRAIN TEST AND DRAIN b ASSEMBLY ASSEMBLY --- LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY CONFIGURATION REPRESENTATIVE OF SIZES 1 1/4"THROUGH 2 1/2" FIGURE 3: MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY LEFT HANDED VS RIGHT HANDED AUG 2021 GFV-120 Page 4 of 14 TABLE A: 1'/4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/4" R GL300T MXF THREADED 1" 317800-R-B-H 24.0 (10.9) 1 1/4" R NONE MXF THREADED 1" 317800-R-H 19.0 (8.6) 1 1/4" L GL300T MXF THREADED 1" 317800-L-B-H 24.0 (10.9) 1 1/4" L NONE MXF THREADED 1" 317800-L-H 19.0 (8.6) 1 1/4" R NONE GXG 1" 317843-R-H 19.0 (8.6) 1 1/4" R GL30OG GXG 1" 317843-R-B-H 24.0 (10.9) 1 1/4" R SERIES 728 GXG 1" 317843-R-V-H 24.0 (10.9) 1 1/4" L NONE GXG 1" 317843-L-H 19.0 (8.6) 1 1/4" L GL30OG GXG 1" 317843-L-B-H 24.0 (10.9) 1 1/4" L SERIES 728 GXG 1" 317843-L-V-H 24.0 (10.9) TABLE B: 1%" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/2" R GL300T MXF THREADED 1" 317803-R-B-H 24.0 (10.9) 1 1/2" R NONE MXF THREADED 1" 317803-R-H 18.3 (8.3) 1 1/2" L GL300T MXF THREADED 1" 317803-L-B-H 24.0 (10.9) 1 1/2" L NONE MXF THREADED 1" 317803-L-H 18.3 (8.3) 1 1/2" R NONE GXG 1" 317844-R-H 18.3 (8.3) 1 1/2" R GL30OG GXG 1" 317844-R-B-H 24.0 (10.9) 1 1/2" R SERIES 728 GXG 1" 317844-R-V-H 24.0 (10.9) 1 1/2" L NONE GXG 1" 317844-L-H 18.3 (8.3) 1 1/2" L GL30OG GXG 1" 317844-L-B-H 24.0 (10.9) 1 1/2" L SERIES 728 GXG 1" 317844-L-V-H 24.0 (10.9) TABLE C: 2" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TESTAND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 2" R GL30OG GXG 1" 317806-R-B-H 26.0 (11.8) 2" R SERIES 705 GXG 1" 317806-R-V-H 26.0 (11.8) 2" R NONE GXG 1" 317806-R-H 19.2 (8.7) 2" L GL30OG GXG 1" 317806-L-B-H 26.0 (11.8) 2" L SERIES 705 GXG 1" 317806-L-V-H 26.0 (11.8) 2" L NONE GXG 1" 317806-L-H 19.2 (8.7) AUG 2021 GFV-120 Page 5 of 14 TABLE D: 2'/2" (DN65)/76.1 MM MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 21/2" R GL30OG GXG 1 1/4" 317809-R-B-H 31.0 (14.1) 2 1/2" R SERIES 705 GXG 1 1/4" 317809-R-V-H 31.0 (14.1) 21/2" R NONE GXG 1 1/4" 317809-R-H 23.5 (10.7) 21/2" L GL30OG GXG 1 1/4" 317809-L-B-H 31.0 (14.1) 2 1/2" L SERIES 705 GXG 1 1/4" 317809-L-V-H 31.0 (14.1) 21/2" L NONE GXG 1 1/4" 317809-L-H 23.5 (10.7) 76.1 mm R GLR30OG GXG 1 1/4" 317809-D-R-B-H 31.0 (14.1) 76.1 mm R NONE GXG 1 1/4" 317809-D-R-H 23.5 (10.7) 76.1 mm L GLR30OG GXG 1 1/4" 317809-D-L-B-H 31.0 (14.1) 76.1 mm L NONE GXG 1 1/4" 317809-D-L-H 23.5 (10.7) TABLE E: 3" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 3" R GLR30OG GXG 1 1/4" 317812-R-B-H 59.0 (26.8) 3" R SERIES 705 GXG 1 1/4" 317812-R-V-H 59.0 (26.8) 3" R NONE GXG 11/4" 317812-R-H 35.4 (16.1) 3" L GLR30OG GXG 1 1/4" 317812-L-B-H 59.0 (26.8) 3" L SERIES 705 GXG 1 1/4" 317812-L-V-H 59.0 (26.8) 3" L NONE GXG 1 1/4" 317812-L-H 35.4 (16.1) TABLE F: 4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TESTAND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 4" R GLR30OG GXG 2" 317817-R-B 87.5 (39.7) 4" R SERIES 705 GXG 2" 317817-R-V 87.5 (39.7) 4" R NONE GXG 2" 317817-R 58.9 (26.7) 4" L GLR30OG GXG 2" 317817-L-B 87.5 (39.7) 4" L SERIES 705 GXG 2" 317817-L-V 87.5 (39.7) 4" L NONE GXG 2" 317817-L 58.9 (26.7) AUG 2021 GFV-120 Page 6 of 14 TABLE G: 6" (DN150)/165.1MM MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 6" R GLR30OG GXG 2" 317818-R-B 124.5 (56.5) 6" R SERIES 705 GXG 2" 317818-R-V 124.5 (56.5) 6" R NONE GXG 2" 317818-R 80.0 (36.3) 6" L GLR30OG GXG 2" 317818-L-B 124.5 (56.5) 6" L SERIES 705 GXG 2" 317818-L-V 124.5 (56.5) 6" L NONE GXG 2" 317818-L 80.0 (36.3) 165.1 mm R GLR30OG GXG 2" 317818-D-R-B 124.5 (56.5) 165.1 mm R NONE GXG 2" 317818-D-R 80.0 (36.3) 165.1 mm L GLR30OG GXG 2" 317818-D-L-B 124.5 (56.5) 165.1 mm L NONE GXG 2" 317818-D-L 80.0 (36.3) TABLE H: 8" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY UMC BODY MODEL UTD APPROXIMATE SIZE CONTROL END TEST AND PART NUMBER WEIGHTS R-RIGHT VALVE CONNECTIONS DRAIN SIZE LBS. (kg) 8" R Series 705 GXG 2" 317798-01 177 (80.3) 8" R NONE GXG 2" 317798-02 123 (55.8) AUG 2021 GFV-120 Page 7 of 14 FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00 6.00 - - 0.40 5.00 - - 0.30 4.00 lk�Nv d Q 3.000.20 W U) 0 W 2.00 --- - p /6b w o D o W `�° �p� p= 0.10 W a o� "gyp=�° 0.09 a 0.08 0.06 0.80 0.90 /- - 0.70 -- - - -- 0.05 0.60 0.04 0.50 40 50 60 70 80 90100 200 300 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4" = 6 feet • 2%" = 14 feet 6" = 30 feet • 1'/2" = 9 feet • 3" = 11 feet 8" =23 feet • 2" = 8 feet • 4" = 14 feet FIGURE 4: MODEL UMC MANIFOLD CHECK (WITHOUT BFV) FRICTION LOSS CURVES 11/4" TO 8" FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00 6.00 tII 0.40 5.00 � I --- --- 0.30 4.00 - - - - ly a 3.00 ^fro ao �h 0.20 00 U) h ry W 2.00 -��"�ti. . . . �_ --- W O� (n W o p 0.10 W a oz� 0.09 a 0.08 1.00 - - - - 0.07 0.90 - --- 0.06 0.80 - - 0.70 - - _ 0.05 0.60 - - 0.04 0.50 - 40 50 60 70 80 90100 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4" = 8 feet 2'/2" = 22 feet 6" = 38 feet • 11/2" = 11 feet 3" = 17.5 feet 8" = 27 feet 2" = 12 feet 4" = 18.5 feet FIGURE 5: MODEL UMC MANIFOLD CHECK (WITH BFV) ASSEMBLY FRICTION LOSS CURVES 11/4" TO 8" AUG 2021 GFV-120 Page 8 of 14 TABLE I: MODEL UMC AND BUTTERFLY VALVE END TO END DIMENSIONS Butterfly Control Valve End to End Dimen- End to End Dimension Size Butterfly Valve Model End to End Dimension sion Without Butterfly With Butterfly Control inches (mm) Control Valve inches Valve (mm) inches (mm) 1 1/4" 2.64 10.75 12.89 MT x FT GL300T (67.9) (273) (327) GL30OG 101.E '91 1 114" ( ) 11.4 (3 ) G x G 7.25 (290) 18.65 SERIES 728 (184) (474) 1 112" 2.87 10.75 13.12 MT x FT GL300T (73) (273) (333) GL30OG 4.1 15.5 1 1/2" (104) 11.4 (394) G x G SERIES 728 7.25 (290) 18.65 (474) GL30OG 4.49 14.49 2„ (114) 10 (368) G x G SERIES 705 4.25 (254) 14.25 (108.0) (362) GL30OG 4.49 15.12 2 1/2" (114) 10.63 (384) G x G SERIES 705 3.77 (270) 14.4 (95.8) (365.8) GL30OG 4.49 15.12 65 mm (114) 10.63 (384) G x G SERIES 705 3.77 (270) 14.4 (95.8) (365.8) -7 GLR30OG 3.8 16.05 3„ (96.4) 12.75 (42 ) G x G SERIES 705 3.77 (324) 16.52 (95.8) (419.6) GLR30OG 4.5 19.13 4„ (115.4) 14.63 (486) G x G SERIES 705 4.63 (371) 19.26 (117.6) (488.6) GLR30OG 5.2 22.64 6„ (132.4) 17.44 (575) G x G 5.88 (443) 23.32 SERIES 705 (149.4) (592.4) GLR30OG 5.2 22.64 150 mm (132.4) 17.44 (575) G x G SERIES 705 5.88 (443) 23.32 (149.4) (592.4) 8 SERIES 705 5.33 27.0 32.71 G x G (135.4) (685.4) (830.4) AUG 2021 GFV-120 Page 9 of 14 ® c ®LL e0 *Dl LL 4 = 0A B D GB C E A C E A B C D E F G H I SIZE Inches Inches Inches Inches Inches Inches Inches Inches Inches (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 1 1/4"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/4"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 (79) (157) (214) (150) (170) (301) (50) (290) 1 1/2"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/2"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 (79) (157) (214) (150) (170) (301) (50) (290) 2„ 3.9 5.4 7.6 6 6.8 11.9 2.1 10 (99) (136) (193) (150) (173) (301) (53) (254) 2 1/2" 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 (84) (171) (233) (157) (182) (312) (58) (269) 76.1 mm 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 (84) (171) (233) (157) (182) (312) (58) (269) FIGURE 6: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 11/4" TO 21/2" Q o i % F P O O H LL 2 J A o B A-� ID � �C E j G 311-C,' Q„ A B C D E F v G H SIZE inches inches inches inches inches inches inches inches (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 3" 6.5 6.9 9.4 _ 6.4 16 2.4 12.7 (165) (176) (238) (161) (406) (61) (324) 4" 7 8.3 11.2 5.6 7 17.7 3 14.6 (177) (210) (284) (143) (178) (449) (76) (371) 6" 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 165.1 mm 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 6.5 8.38 11.25 10.6 6.0 29.62 27.18 8 (165) (213) (286) (269) (152) (752) NA (690) FIGURE 7: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 3" TO 8" AUG 2021 GFV-120 Page 10 of 14 FLOW SWITCH REQUIREMENTS The Model UMC Floor Control/ Shotgun Riser assembly is in the replacement parts section of the technical literature. sold inclusive of a Potter VSR flow switch. The flow switch The Potter VSR Flow switch includes 2 sets of switches, utilizes exactly the same electrical and switch components one set can be used to activate the central fire alarm system as the Potter VSR flow switch but includes an adapter which while the other set can be utilized to activate a local alarm (if attaches directly to the Model UMC Manifold Check as- necessary). See figure 8 for a typical wiring diagram for the sembly. This adapter has been tested as part of the UMC Model VSR Flow switch. assembly to ensure the hydrostatic strength as well as the placement and sensitivity of the paddle is within the criteria Note:For more information on the flow switch see wwwpottersignal.com. set forth by UL and FM. The part number for the flow switch assembly can be found WIRENUT LOCAL WIRE NUT FIRE PANEL OR AUDIBLEMSUAL ADDRESSABLE ANNUNCIATOR MODULE NEUTRAL F W WHITE WHITE BLACK U% BLACK (LINE/HOT) P.0 r < 0 m J 0 0¢a 0 U O 2 s m O D wuw wierum �� .xev. xa xo FIGURE 8: MODEL VSR-M FLOW SWITCH TYPICAL WIRING DIAGRAM RED — RED S-1 FIRE ALARM COMMON (WHITE) I I COMMON (WHITE) CONTROL PANEL END OF LINE SUPERVISORY YELLOW YELLOW RESISTOR CIRCUIT GREEN I OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC GEAR OPERATOR) ORANGE I S-2 COMMON (BLACK) BLUE VOLTAGE AUX. DEVICE SOURCE ______________________________ (BELL/HORN) VALVE WIRING SHOWN WITH VALVE IN OPEN POSITION FIGURE 9: GL300T, GL300G, AND GLR30OG BUTTERFLY VALVE WIRING DIAGRAM AUG 2021 GFV-120 Page 11 of 14 - -1 L(F__ .FIRE ALARM COMMON (YELLOW) I COMMON (YELLOW) CONTROL PANEL END OF LINE SUPERVISORY BLUE BLUE RESISTOR CIRCUIT GREEN I OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC GEAR OPERATOR) BROWN/ORANGE II S-2 I COMMON (YELLOW/ORANGE) BLUE/ORANGE VOLTAGE AUX. DEVICE SOURCE ______________________________ (BELL/HORN) VALVE WIRING SHOWN WITH VALVE IN OPEN POSITION FIGURE 10:SERIES 728 AND 705 BUTTERFLY VALVE WIRING DIAGRAM SWITCH AND WIRING 1. The supervisory switch contains two single pole, double throw, prewired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the"OPEN"position. 4. One switch has two#18 insulated wires per terminal,which permit complete supervision of leads(refer to diagrams and notes below).The second switch has one#18 insulated wire per terminal.This double circuit provides flexibility to operate two electri- cal devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5. A#14 insulated ground lead (green)is provided. Switch#1 =S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2 =S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 Normally Closed: (2)Blue Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe AUG 2021 GFV-120 Page 12 of 14 INSTALLATION TESTING The Model UMC Floor Control/ Shotgun Riser assembly is Reference NFPA 25, Standard for the Inspection, Testing sold as a complete unit, assembled and shipped in a single and Maintenance of Water-Based Fire Protection Systems. box. Before proceeding with any tests involving water flow, the The Model UMC Manifold Check Valve must be installed in following precautions need to be taken: an accessible and visible location, which is maintained at STEP 1. Check the location where the test connection or above a minimum temperature of 40°F (41C). The UMC discharges to make sure that all is clear and may be installed in the horizontal or vertical (flow upward) that there is no possibility of the water flow orientation. causing damage or injury. All valves must be installed in accordance with the ap- STEP 2. Check the end of the test connection to make propriate installation standard (i.e. NFPA 13 or other). All sure that it is unobstructed. To achieve a satis- electrical connections must be made per the applicable in- factory test, there must be an unrestricted flow stallation standard and/or the National Electric Code (i.e. of water when the test valve is wide open. NFPA 70, NFPA 72 or other). STEP 3. Check for alarm connections to a central sta- Proper hydrostatic test procedure must be followed per tion or fire department. If such connections are NFPA 13. found, give proper notice to the signal receiv- It is not necessary to remove the ARV Relief Valve prior to ing station before proceeding with the test. system hydrostatic test. The Adjustable ARV may simply Note:A main drain test may also operate local fire alarms unless they are tem- be temporarily adjusted to a pressure above the test pres- porarily disabled. sure during the hydrostatic test. Be sure to return the ARV Relief Valve to it's normal setting after the completion of the hydrostatic test. MAINTENANCE The owner is responsible for the Inspection, Testing and MODEL ARV RELIEF VALVE Maintenance of their fire protection system. SETTING PROCEDURE System inspection, testing and maintenance shall be per- formed in accordance with this section as well as NFPA 25 The Globe 1/2 inch Model ARV, 300 psi Adjustable Pres- or other applicable Standard to insure the integrity of the sure Relief Valve, is factory set to relieve at a pressure of entire system, including alarm functions as well as other approximately 175 psi (12 bar). system components. Any impairments must be immedi- The Pressure Relief Valve may be reset to a higher pres- ately corrected. sure; however, it must be reset to relieve at a pressure Before closing a system main control valve for mainte- which is in accordance with the requirements of the au- nance work on the fire protection system, obtain permis- thority having jurisdiction, typically nominal 10 psi (.7 bar) sion to shut down the affected fire protection system from above the expected normal system pressure. the proper authorities and notify all personnel who may be To reset the Model ARV pressure relief valve, use an ad- affected. justable crescent wrench, to turn the hex cap clockwise for Note: a higher pressure setting or counter-clockwise for a lower All valves should be carefully inspected,tested,and maintained in accordance pressure setting. Use the calibrated lines on the stem for with NFPA 25 or other applicable Standard. an approximate relief pressure setting. 1 full turn of the It is important to ensure a clean water supply free of debris hex cap will result in approximately 25 psi increase or de- and solid particles such as sand, gravel, or mud. crease. To verify the new setting, isolate the Model ARV relief valve If, during an inspection of a water control valve, sediment and use a small hydrostatic pump attached to the supply. or free particles of matter are noted, a further examination Increase the pressure at the relief valve to 10 psi above of internal valve parts is necessary. the expected normal system pressure. Readjust the ARV All deposits should be removed from all operating parts and as needed to maintain a 10 psi higher relief setting. ports. Where difficulty in performance is experienced, the manu- facturer or its authorized representative shall be contacted before any field adjustment is to be made. UMC Clapper Facing.The rubber clapper facing should be checked for wear or damage and to determine that it is free of dirt and other foreign substances. If found to be worn or damaged (e.g., foreign matter embedded in the surface; cut or torn facing), the facing should be replaced. If it is dirty, it should be cleaned. Compounds which could dam- age the rubber facing must never be used. Should clapper facing replacement become necessary, the following steps should be performed; Note:Before performing the following steps, insure that the system has been depressurized and drained. Clapper Removal STEP 1. Remove handhole cover. STEP 2. Remove hinge pin plugs from front and back of UMC. STEP 3. Using allen wrench, push hinge pin from back of UMC towards front. AUG 2021 GFV-120 Page 13 of 14 STEP 4. Once hinge pin is accessible, carefully grab REPLACEMENT PARTS with pliers or similar to pull hinge pin out of body. MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE Note:Care must be taken to confine clapper spring while extracting hinge pin REPLACEMENT PARTS/KITS from body.Spring is under tension around hinge pin. It is also recommended to cover drain port to minimize the possibility of spring inadvertently dropping VSR-M FLOW SWITCH with ADAPTER (includes gas- into drain piping. ket) STEP 5. Carefully remove clapper assembly from UMC. SIZE PART NUMBER Clapper Replacement. When replacing clapper, be sure 11/4' - 2" . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144802-A-G clapper spring has been properly positioned around hinge 2'/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144825-A-G pin such that tension is applied to the clapper by the spring. 3... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144803-A-G 4... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144804-A-G Seat Ring. The seat ring should be checked for nicks and 6" 91144806-A-G for stones, dirt or other foreign matter. It should be cleaned thoroughly. If the seat ring is found to be damaged, UMC 8... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144808-A-G should be replaced. MODEL UTD TEST AND DRAIN Water Flow Switch (VSR-M). There is no maintenance re- (SEE GFV-570 for more information) quired, only periodic testing and inspection. Should switch Specify: MODEL UTD TEST AND DRAIN WITH RELIEF be found to be malfunctioning, refer to Potter Signal Techni- VALVE,SIZE (1", 11/4", or 2") PN: cal Literature for guidance. SIZE PART NUMBER Model ARV Adjustable Relief Valve. Valve is not field ser- 1, (DN25 . . . . . . . . . . . . . . . . . . . . . . . . . S01 OUTDGAO viceable. If inadvertent leakage is observed, first test the 1/4 (DN32). . . . . . . . . . . . . . . . . . . . . . . . . S012UTDGAA pressure setting utilizing the procedure outlined in the ARV 2" (DN50). . . . . . . . . . . . . . . . . . . . . . . . . S020UTDGA4 Relief Valve Setting Procedure. If valve does not respond Specify: MODEL UTD TEST AND DRAIN,SIZE (1", 11/4", or to field adjustments, valve shall be replaced. 2") PN: Note: SIZE PART NUMBER Visual calibration lines on valve are used for approximate adjustment. Verify 1" (DN25). . . . . . . . . . . . . . . . . . . . . . . . . S01 OUTDGAO pressure setting with pressure gauge. 1'/4'(DN32). . . . . . . . . . . . . . . . . . . . . . . . . S012UTDGAA Model UTD Universal Test & Drain Valve: The Globe 2" (DN50). . . . . . . . . . . . . . . . . . . . . . . . . S020UTDGA4 Model UTD Universal Test and Drain Valve does not re- quire any regularly scheduled maintenance. The UTD is not field serviceable. MODEL ARV RELIEF VALVE (SEE Victaulic 30.74 for more information) Specify: MODEL ARV 1/2"ADJ RELIEF VALVE PN. ORDERING INFORMATION . . P0047470PR Note: MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE ASSEMBLY 300 psi(20.6 Bars)Pressure Gauges Standard(600 psi(41.2 Bars) Ordered Specify: MODEL UMC MANIFOLD CHECK VALVE Separately ASSEMBLY,SIZE (11/4", 1%", 2", 2'/z", 76.1 mm, 3", 4", 6", PN......................................300121-D 165.1 mm, 8") PN (see Part Number in Table A-G) Note: Control Valve Model based on availability at time of order. See appropriate GLOBE® PRODUCT WARRANTY Tables for end-to-end dimensional information. Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 •989-846-4583•www.globesprinkler.com • Technical Support•989-414-2600•techservice@globesprinkler.com AUG 2021 GFV-120 Page 14 of 14 EDDY F r � AlwaVs reaft to protect Vour most valuable assets. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product information O.D.(in) 1.660 1.900 2.375 2.875 3.500 4.500 I.O.(in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty weight(Ib/ft) 1.222 1.844 2.330 2.809 3.361 4.968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 Lift Weight(Ibs)21'lengths 1,565 2,362 1,810 1,770 1,341 1,982 Lift Weight(Ibs)24'lengths 1,789 2,700 2,069 2,022 1,533 2,265 Lift Weight(Ibs)25'lengths 1,864 2,812 2,155 2,107 1,596 2,360 r 1� EDDY FLOW ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved We have the most stocking locations in the industry, • ASTM A135 and A795 Type E,Grade A Certified for best delivery and availability • Complies with NFPA-13,13R and 14 Plain end or roll groove •• Industry-leading hydraulic characteristics Eddy Guard II'"bacterial-resistant internal coating • Custom length options • CRR of 1.0 and greater Hot dipped galvanization • All pipe NDT weld tested Reddi-Pipe°red or black pipe eliminates field painting • Compatible for use in wet,dry, preaction and deluge sprinkler systems ■Exclusive maker I ■ I 1I D O■ BLAEK PAINTED PIPE. The only maker with EPDs(to help earn LEED points). c us LISTED <*> M#�# IYNFSA APPROVED IrFPiA va, 800.325.4467 sales@BullMooseindustries.eom -Imff muse ■ As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. ' ' I I Ir O.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.660 1.900 2.375 2.675T758010.800 I.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 — 7.380 7.670 2.067 2.469 Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 2.270 2.720 3.660 5.800 Water Filled Weight(Ib/ft) 1.820 2.516 3.053 4.223 5.893 1.957 11.796 23.038 40.066 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 15.27 9.91 7.76 5.27 4.92 3.54 2.50 1.158 1.805 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 91 61 61 37 30 19 19 10 7 51 44 30 30 19 19 Lift Weight(Ibs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weight(Ibs)24'lengths 3,019 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,846 2,178 2,872 2,635 4176 3456 4,925 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,894 2,992 2,745 4.350 3.601 5,130 SCHEDULE 10 R 40 ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved We have the most stocking locations in the industry, • ASTM A135 and A795 Type E,Grade A Certified for best delivery and availability • Complies with NFPA-13,13R and 14 Plain end or roll groove •• Industry-leading hydraulic characteristics Eddy Guard II'"bacterial-resistant internal coating •• CRR of 1.0 and greater Custom length options • Hot dipped galvanization • All pipe N DT weld tested Reddi-Pipe°red or black pipe eliminates field painting • Compatible for use in wet,dry,preaction and deluge EXCIusiv maker I I 1 ' I sprinkler systems .D OR BLAEK PAINTED PIPE. The only maker with EPDs(to help earn LEED points). c us LISTED FM �► 01, ONFSA APPROVED IIIPPK �� ,�1 800.325.4467 sales@BullMooseindustries.com Y : I T Rff UPON ODTOLCOO www.tolco.com 00: Fig. 200 - "Trimline" Adjustable Band Hanger C@ USLlsren Fig. 20OR (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. ® "-- Features — _ • (1/2" thru 2") Flared edges ease installation for B `I B all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. A • 1 " u ------ securely/2 thru 8 Spring tension on nut holds it ;y_ ( ) P 9 securely in hanger before installation. Adjusting nut is easily removed. Fig.20O 1"-2" Fig.200 21/2"-8" Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA(UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual ` Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and -------- Manufacturers Standardization Society SP-69, Type ® - 10. B Maximum Temperature — 650OF B Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size A Note — Figure 20OR (import) with retainer ring and A non-captured knurl nut. --- Fig.20OR 21/2"-8" Fig.20OR 1/2"-2" Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 m CUSTOMER SERVICE•800.786.5266 www,tolco.com BRONZE BUTTERFLY VALVE - GROOVED "BUTTERBALL" ARbCO SINCE © 1981 ��� • Connections: Grooved Ends (AWWA C606) - - • Sizes: 1", 1-1/4", 1-1/2", 2", 2-1/2" 3" • Approvals: UL, ULC, FM • Maximum Working Pressure: 30OPSI (Max. Test Pressure: 60OPS1) • Maximum Working Temperature: 250°F (120°C) • Application: Indoor and Outdoor Use • Factory-Installed Supervisory Tamper Switch Assembly 1 37 C @US C FM OS LISTED APPROVED � ---I--- - MATERIALS Components Material Specification Body Bronze ASTM B505 Disc Aluminum Bronze ASTM B548 Disc Encapsulation EPDM Rubber ASTM D2000 Indicator Brass ASTM B16 Housing Steel ASTM A619 Handwheel Steel ASTM A619 Stem Stainless Steel ASTM A564 Type XM1 K-7 DIMENSIONS Item # Size A B C D E F6520291A 1-1/4" 3.9" 1.7" 1.5" 0.6" 0.3" 2.2" 6520292A 1-1/2" 4.1" 1.9" 1.8" 0.6" 0.3" 2.3" 6520294 1 2" 4.5" 2.4" 2.2" 0.6" 0.3" 2.5" o 6520296 2-1/2" 4.5" 2 9" 2 7" 0.6" 0.3" 2 9" System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com i(ARGCO Updated 3/10/2022 ©ARGCO ARGCO. 60 T-1015 BRONZE BUTTERFLY VALVE - GROOVED "BUTTERBALL" UPOR © WIRING DIAGRAM SWITCH SHOWN POSITION WITH VALVE IN FULL OPEN SWITCH 1 : DUAL LEADS SOLDERED TO SWITCH TABS BLACK SUPERVISORY TO NEXT INDICATOR CIRCUIT OF A OR LISTED FIRE ALARM NC END-OF-LINE RESISTOR CONTROL PANEL WHITE COMMON 1 NO RED SWITCH 2: SINGLE LEADS SOLDERED TO SWITCH TABS ORANGE AUXILIARY EQUIPMENT NC VOLTAGE BLUE SOURCE COMMON NO YELLOW Green wire is provided as ground for the switch housing. Switch rating: 10.lAmps-125/250VAC-60Hz Actual switch application rating: 10 Amps/115 VAC-60Hz,0.5 Amps/28 VDC SUPERVISORY TAMPER SWITCH (FOR INUOORIOUTDOOR USE) 112'ELECTRICAL CONDUIT O m-o w m � q® 0 0 0� 0 CD ormyo 0az y 0 M O LUL LISTED JUNCTION aOX Installation must comply with NFPA 13 and NFPA 72. Cap unused leads with wire nuts and tuck into a junction box(not provided). System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 3/10/2022©ARGCO AGOO.— e00_a54_1015 �i MI■I E LU M �,�•� ■I■I � x m 1�■N.N�■nnNYn1111111.....■■■■■■■■■■■■�nn111111 n1■■■■■■■■N■■■M... • �aN����1111111111111■11■■■■■■■�gY111111N1■■■■■■■pqq■M... w\`�pN����11111111111■■■■■■■■■■qqp gn111111 N1111■■■■p■■■..... M�`'�p��=�11111111111111111�1■■ggYgn111111N111■■■■■p■qqH=■■ • wY1w��p1��11111111111■111■■■1■1lgpgn111111■11111■■■NggqN..■ • s1= -_:a=ma:RIMI=IEEE°:eee'se;s=55■e5:s:■.::":eeee':e•111ee::191 I:�A�I��:�I���:.ii::::::ii•ii11■Itii 111122,023NNN • .oN..•....•uN���w nuwoauoou N���A�NNA • ANI�NN�NA��:::.■.►.i.....■•■...■■■�tl NH:::■■.N•.�•.■■w NtltltlM... ANI�NNNNN��I......■►w ■•.••••••■■tlN NN1■■■■■N■■••••■•N■■■MINNN N������N�A.III■■■■■■■►��■■■■•■■■■■N II1Nsa...p■■■■■■.■�.tltlA■NNN NNI�NNNNN�M IN111111111■EN 1:....■■N■1.11111■■■■■■■•.•.■.■■■M... N��N�Nn■■.I..11111■■lN 1■1A�..■..■■■n■111.1111 NN.■..■.N■■■MN.. Nib..■�NN..n�1111111111111.1■■��..■■N 1n11111■1.■.......�.tltl N... LL NNlnl■MN�Nn■��III1I n■111■1.1■...�7■■ntl11n111111 N.....■.. ■■■Man . w•■.NI�0102SCmummuuuo 10401 unuannoopo■Mmom • nl•mmmm�■� mxnuuun..nu■►�nnnu.n.nuuua■■■M... ■IiiiNNNI.■ ■i11111111■11...■.■■■■■■■■\!.N1111.1..■■■■■..N■■■Y.... • w�pNN����111111111111■1■1■■■■■■■NI■i�11111H■■■■■■■■NY■q■.... M�q.gN��gqlN■1111111111 Islas 1■■■■■ggaq111.:�11N1111■■■■N■■■Y.... • •• ■■�p�p�pl�gg1111111111111111111111ggqq 111111111:V 11■■■■■■pggq■■■■■ M�pppplpl�gg111111 vigil 1111111111 mom�11n111111 M:g11111■pggq■■■■■ Mglpppp pl��11111111111111111111■lpmq g11111111g11�:�1111pppmm■■■■ M■■q■ ��1111111111111111111111gw RRIIIIII MINOR pomp■■■■■ ■■■MMMMEM1111111111 Hill 11111 Moon m■111111■111111ok6 9100M■■■ ■_■■■■■mmm m11111111111111111111moo=RNllllll■111111111pkiz\■■■■■ • ■■■w■■■��IIIIIIIIIIIIIIIIIIII�Noon NI■IIIIIIINIIIIIIII�■�■B�■ • Q� N■N■■■��IIIIIIIIIIIIIIIIIIIII■■■N■111111■11111111■■■■N■■ki c �■■1■■■■��IIIIIIIIII111111111111■■■NIIIIIIIIIIIIIIII■■■■■■■■■ •� Ii Y■IN■■■■��IIIIIIIIIIIIIIIIIIIIII■■Inllllll■11111111■111■■■■■ � � �■�■■■■■IIIIIIIIIIIIIIIIIIIIIII■111111111■11111111■IIIn■■■ ■■�w■■■■■IIIIIIIIIIIIIIIIIIIIIII■IIIIIIIIIRIIIIIIII■111®��� � ■■N■■■■■IIIIIIIIIIIIIIIIIIIIIII■IIIIIIIIIIIIIIIII■111■111 ■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■111111111111111111■111■111 o i 1�■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■111■111 _■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■111■111 • '� � '_=====EeeEeEee'E6eeeeeeEee: eeeeeeeee 'e::e5 :__==== • C AAAIAINN__A.��_.................•...����n........N........N���M�== • �_AA AINN�A.A�AN...............•.....��A n.........•.•••....N.��M�NN �I NiiNNtl��N�ANI.......N11.•.•..•..�tlN tlY.....■N..•••...N.■tltltl�N� •• NiiN�NNNNNN I.I........•.•....■..■■N tl.......■A..••....■tltltl■tltl.NN NNINNI�NN.NNIIIII1.N111111.......�N■11I1111111111.....N■■■MNNN � NiiN�NNN.NN II11I I11111.■111.....■■N In1I1111111111.....p■■■■..NN N/iNN�NNNNNNx111 IN111N1..1.111..■11.1........■■■■■N n1111111.....M■■■MNNN • YiiNN■��N�ni 11111 N tl NNxtlllllll N..■■.....■■■tlMNN. .��nn.�n■Nln.nn1111111n1.1...■...■.■■■■n nn1111.1N........N■■■M... • • D v w�nM.�Nn■n...1111111n1 n.....■...■■■n nlllll■111......■■■.■■■■M... ■��.N�NNMnn1111111111111■...■■■..■■■n xnllnll l.........■■■■■M... • • � ■�i■n.��N1��1111111■.11■■1.....■■■■NIIYII■1■111.■.......■■■■M... • w��NN■■■.��11111111111111■■■■■■■■■NI NY111111.11■■■■■■■■■■Yq.... �C�pZ�S�111111111111IIII111I11C■RIIIIIIIIIIIIIIIIIC�=:::IIS CL S r�Ap�pl�gg1111111111111111111111gqY1111111111q11111111ppqq■■■■■ • s �axo211 a:o:x:::I:::ZIECti-XIC �ZIiCmam ........ ......1 ..........C�■_■a li NAIAINNNN\��II...........••.....■■■�.N......NA........N���N■NNN Nii�NI��N��I......1111111......■■tlN I11......■q11•.....YtltltlNI.NN Niii��NN.N.\�.'1II I111....111.......tltl I1tl111.1111111.....N■■■...NN NiiNN■�NNNY�`�1111111 N■.■1.....■■N xtl111111 N..1......■■■■..NNN Niii��NNNtl�fI.`�11111111..11....■■N tlx111111 N........■■■tl■MNNN ■i IInI' 1�1■... ■.. ■■■1111NI 11 ■qp■ ..■ A ■■M. ■TT.■■N1:a 1111111._.11..ii...0 C1■N■Illlllll l..iii.■.0 n.Z■.M.�■ w u■ Ym mn ■ ■ Y. 1■=��■:�1■�I:II...11::_:, .iliii7■■Salt:plYll.11.gp.l..iilis.■iw.;.=IM=■*■■ . • ■��p��q■■�11111�111 I��������Q\I�pgH IIIIIB���I�1�11q�li�q�q��■ P • w�Np�pI�YN111111111111111111111��gg11111111N11■■■111p■qqM■■■ ZF +a M■ppp����111111111111111111111pm��gn111111■11111111pppmN■■■ � 1`+ Mml■Ipp����111111111111111111111ppN®g111111g11111111pppmmm■■■ 4 • MOMlppl�m■m■111111111111111111111pmmmg111►.VI■11111111pmmmm■■■■ 7.� � ml■■mm■���mmlm■11111111111111111oo11pNEM IIm11111:!1�1111111 ppmmm■■■■ C • ■ml■■�m■m■m■111111111111111111111pmm11m111111H■:�IIp11Npm■■■■■■ v • ■ ■����111111111111111111111pmq■■111111■111�:!IlBpmmN■■■ • IZ Mu w r■�■■���IIIIIIIIIIIIIIIIIIIp1■■■■■IIIIIINIIIII���\■■■■■■■■ ■■■u■■■��111111111111111111111■■■g■g11111111gq11111111�:�■N■■■ p O x r • ■■■■■■■ ■I�IIIIIII���1111��1�11 ■IIII INIIIIIII�■1���1��� U ■■■N■■■■■IIIIIIIIIIIIIIIIIIII111■I■IIIIII■11111111■111■■■■ � o o N . ■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIINIIIIIIII■111n��� ■■N■■■■■IIIIIIIIIIIIIIIIIIIIIII■NNIIIIIIIIIIIIIII■111NIII ~N ■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■11111111 � '��= � '� ■�■■■■■■IIIIIIIIIIIIIIIIIIIIIII■11111111111111111■111■111 = 1��■■■■■■IIIIIIIIIIIIIIIIIIIIIII■11111111111111111g111■111 . Ln .. z � Eg • an, ONO - • • W .E. �� • I Q .. • GENERAL NOTES KEY NOTES BUILDING INFORMATION SYSTEM DESIGN - System Design to be per NFPA .t z 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. O Denotes Hydraulic Node CONSTRUCTION TYPE: III-B #13 2019 Edition Lu ' $ 2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED Per NFPA 13 Table 23.6.1: > d 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS + Denotes 4-Way Sway Brace 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS OCCUPANCY: S-1/B(WAREHOUSE/OFFICE) Group A Plastics,Exposed Nonexpanded in Single,Double,or ''v•.,.,: ,..,. -,-; - ¢ y o 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS I Multiple-Row Racks(no open-top containers) - 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS r Denotes Lateral Sway Brace 172ND ST. NE. 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER TOTAL AREA: 186,873 SQ FT(WITH 2,707 SQ FT OFFICE Maximum Storage Height 35'-0"Without Solid Shelves CD PIPE FROM FREEZING W o 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED Denotes Longitudinal Sway Brace SPACE) Maximum Ceiling(Roof)Elevation 40'-0" 7 0 IN ACCORDANCE WITH NFPA-13 Utilize K16.8 ESFR Pendent Sprinklers 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES LL (WIRING BY OTHERS) FF It Denotes Finished Floor to Center of Pipe ROOF HEIGHT: 38'-0 12 Sprinklers Operating at a Minimum pressure of 52psi z 10.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. 250gpm Hose Stream Allowance Y SITE 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. Q Lu r 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. TS It Denotes Bottom of Deck to Center of Pipe Maximum Coverage per Sprinkler 100 sq.ft. Q - m 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW ESFR Pendent Sprinkler Max Deflector Distance from Ceiling 14"(6"Min) z SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) - -. 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. j - - WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS F- Lid a 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF 2'-0" _ fit HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 1i " 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. --H 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR VICINITY MAP Z z er.xaox r x,�.a s1lwan rt erl '3358-0B15-C-H L 3 I"NLlR aT3T AFP Sy-,I.. AFPSYI• im a .................. . I 5 1 Z i m d a s A IL c @ F L` YO m Z 41 Z (3MT —I y City of Arlington a N SYS 5-FP6 SYS 4-FP5 ISYS 3-FP 4 SYS 2-FP3 SYS 1 - FP2 Building Department LL a y OIL - 38533 SQ FT 38611 SQ FT 40000 SQ FT 33860 SQ FT 3665 APPROVED a Kevin Olander- 07/21/2025 us z No changes authorized unless approved by c ` c c c M 0 the Building Official `o 'R C 4 OIL F h CLY 0 x f ai w 3 t7 � 0 r m m m OLL 0 LL w 0 z s w � Q z Z n y w F d 'D II o Z Y a c ai o 0 0 0 f r r r w w _.. o y - F 25'FIRELANE ° y •4 o PERM"`C N THIS AREA x 9 WATER MODEL DATA FROM - F EXISTING HYDRANT s I Supply Flow Test Data FL-L _ Static Preasure 90.000 �aa W Residual Pressure: 48.00000 U, 25'FIRELANE AFPI START5'-O OUTSIDE 151 FIOW 3149.00 JOISTOBSTRUCTIONS GIRDER OR BEAM OBSTRUCTIONS ISOLATED OBSTRUCTIONS H -_ ---_ ---_.- OOM Test Conducted By City of Arlington Public Works t t t t z FH 12'DI - FDC I c� L .........._- - --- -- --- --- --- --- -- -- " U ~ o REMOTE RISER BANK PUMP ROOM W I A� ®g g o 6"DI 10"DI N O O U 11 150 _ Tamaoa Tama TRoa TRPa Tmao z NO ossmurnaxsxixcxoauas oasE_RTE xro,+r.wcxcesmurnax a"T o I 10"DI rnoaaaxxxTaoox xlPaaaxRxzaxox .,:r.ro:�xcxoa.rxurnoxazro,z�xcx aaa,xarnox ox.�xcx O Z 00 rcxs°nven xnrexeo.xs. oa uorcxEo�oou oa�oaos°nxen xnrcxe°.xe. U � �Ty U CONTINUOUS OBSTRUCTIONS O me wa C — W DCDA IN VAULT z to po z� Ds 187,115 2 S. (BY OTHERS) ua x° „xx,°k u�„T wxF. x Do a O ZC2 b x� o w w O LIJ VCj F-m FH c 1 FR3y3.E Z a;~^,L cn Q U T a a Z a�Ln¢ D IN 18 DO KADOOsROSS FROM SPRINKLER AUTOMATIC FIRE PROTECTION FHINC. Y GROUPED CONTINUOUS OBSTRUCTIONS MAXIMUM 24"WIDE SYSTEMS,INC .. .. .. 0 aaxaaa„.xwa a O 12"DI 12"DI 12"DI FH FH FH FH �— FH J� SYSTEMS y.� rrJ OBSTRUCTIONS BELOW SPRINKLERS WIDER THAN 24" Cy I„u�"xR a>xxwFx s> T�qF PRO"1E0�\O 19435 SW 129th AVENUE TUALATIN, ESFR OBSTRUCTION RULES FAX: OR-1186 97062 (503)692.9284 FAX:(503)692.1186 NOTTO SCALE WACCB#AFPSY150918Z DRAWN BY: AH DATE: 3/28/25 AHJ: City of Arlington SITE PLAN .ALL UNDERGROUND BY OTHERS-SHOWN FOR REFERENCE ONLY __+ SHEET: 1/64"= 11-0 FP 1 of 7 AFP.PROJECT#: 25034 O GENERAL NOTES w 1s 0 1'-0 5'-2 '-56 1'-0 1'-0 1'-0 1'-0 1'•0 1'-0 1'-0 8' S' 8'-0 1 1 -0 4'� 558 7'-11, -0 SB--- SB-11 B-11 58 266 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. y, 4+ I q2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS �® - - -13 ® ��4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS 0 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS 15 -10 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS 0- 1'-0 5'-2 •-10 1'-0 , -0 1'-0 1'-0 1'-0 1•-0 1•-0 8' s' e'-0 1 -0 1 -0 4'-0 5'-0 T-11 -6 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER n 37 PIPE FROM FREEZING 53 0 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED 4 2'd Tb'/: IN ACCORDANCE WITH NFPA-13 52 t 55 57 5g m r 264 2 w 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES P7 (WIRING BY OTHERS) SB-1 ' 10.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. 15'-10 C; 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. 0 1'-0 5'-2 10 1 0 1-0 1'-0 1'-0 ,'-0 1'-0 1'-0 8' S' 8'-0 1 -0 1 -0 4'-8 5'-0 T-11 -0 ® ` I11 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. 1 m 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW SB•2 SB-9 SBd g SB-2 Mill q SB-9 4 51 m SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) _ m- 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. ,83•-,,. "'1,�' w WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS SBA 1 a 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF Z-0" 15 -10 B'1 HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 0- 1'-0 S'-2 -70 1'-0 ,•-0 7'-0 , '-0 1'-0 1,-0 1'-0 8' 5' % 8'-0 1 -0 7 -0 4'-0 5'-0 T-11: fi 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR 4g qg z Lit �, KEY NOTES 1s -10 0• 1'-0 5'-2 '-10 1'-0 1'-0 1'.0 1'-0 1'-0 1'-0 1'-0 8' S' 8'-0 -0 1 -0 4'A 5'-0 7'-11, -0 ceRrlFlcsre of O Denotes Hydraulic Node q a ;6„n�n K 'v 47 AFPSy—, y+sc-,I Ldel3 I� Denotes 4-Way Sway Brace O b�® ®� AFP bye Pma,lrc. b b b Bw..(w.Stcwnni �) m +n ........7..rz.: Ij Denotes Lateral Sway Brace 15'-10 "v 1 001 1'-0 5'-2 4-10 1'-0 '-0 7'-0 ,'-0 1'-0 1'-0 1'-0 5' 8'4 144 1 -0 4'-S s'd r-11, -0 Y Q 2 3'-'/. .d.. Denotes Longitudinal Sway Brace o!44 as ,-0Y 1'-0,A, Z b q F q 0 FF It Denotes Finished Floor to Center of Pipe d ,s -,o D• TS I Denotes Bottom of Deck to Center of Pipe °- e LL 1'-0 5'-2 '-10 1'-0 1 -0 1'-0 1 -0 1'-0 1 -0 ,'-0 B' S' 8'-0 1 -0 1 -0 4'-0 5'-0 T-11 -6 E 42 43 4 ® 4 O 4 SBd t e iL E _ 15410 m Z G U s o 0• 1'-0 5'-2 "o 1'-0 1 '-0 1'-0 1'-0 1'-0 1 '-0 1'-0 B' S. 81-0 1 -0 1 -0 4'-0 51d 7'-11 a fi 10 41 N 0 a meoeruLs ee�ay. 15 -10 fn Q 0- IS 1'-0 T-2 ``4'.10 1'-0 - 1 '-0 1'-0 1 -0 1'-0 1 '-0 1'-0 g' S' 8'-0 1 -0 1 -0 4'-0 F-4 w LLO 38 c F e e e o ® q J a s a 829'd/: Q7 t; w \�.o,� �RaRe xE.x,. ,�x�«.o•v. ,g.-10 ly °"'a<N.T% . 0- 1--0 T-2 '-10 1'-0 1 -0 1'A 1'-0 1'•0 1'-0 1'-0 8' S. 8'-0 -0 1 -0 T-0 4' 5'd -11, 4 G Y r .om O JOIST OBSTRUCTIONS GIRDER OR BEAM OBSTRUCTIONS ISOLATED OBSTRUCTIONS 35 38 fA i? 3 ICI ! I ICI ICI O b �I =L� AL� a mm �� �Q 1s•-10 a LL W Z a e ®g 0• 1'-0 5'-2 4'-10 1'•0 1 -0 1'•0 1'-0 1'-0 1 -0 1'-0 8' S' 8'-0 , -0 1 .0 4'A 5'-0 7'-11, •6 w Q 32 33 w SB-0 q ®� q y N meoF ioe ioe sloe loco roNeP.RE. I—xm.,,.., H—H.P.gc. H—HeP.gc. w.roNm.Rc. W CONTINUOUS OBSTRUCTIONS m 15'-10 19 .� O 0• 1'-0 5'-2 4'-10 1'-0 1 '-0 1'A 1'-0 1'-0 1'-0 1'•0 8' S' 8'-0 1 -0 1 0 4'-0 5'd 7-11, 6 u mai,.ucruw Ma,ois. � t)� w E .•Ex, _ "LJ1 q ®l q 30 m o 0 0�µ �56; w FRS w o 0 IN ON sI EOFe a N L N,w-1 15M.10 T H MTSPRINKUR 0 4.0 5'-2 10 1'-0 1 -0 - 1'-0 1'-0 ,'-0 1'-0 1'-0 - 8'- 5' V,8 111,0 , -0 4'-8 5'-0 T,11 -6 N z0 .a<»<„,x�x,,. .`�<`„.t„`;x,;1�_. ,0 26 28 3 GROUPED CONjTINUOUS OBSTRUCTIONS-MAXIMUM 24"WIDE - ® e ®� 4 b hcEuixawvixx/Exs F ,5'-,0 G 5''2 �,,.. 1'-0 1 -0 1'-0 1'-0 1'-0 1'-0 1'-0 B'- 5' 8'-0 1 -0 1 -0 4'-0 5'-0 7'-11: 0-6 UJ 25 w �7 4 4 N 15 -10 z = 0- 1'-0 T-2 -4�-10 1,0 1 '-0 1'-0 1'-0 1'-0 1'-0 1'-0 8' S' Y 81-0 1 -0 1 -0 4'-8' S'-0 7'-11, 6 O V J OBSTRUCTIONS BELOW SPRINKLERS WIDER THAN 24" ',9/ 23 10'-0 10'-0 9'-7'/: T-1' V r pO QiNui sPRirvueas ocI q = N SB-4 ®— (f H Q '--I VI J CD ESFR OBSTRUCTION RULES 5'-2 '° y'-° ,'-0 ,'-0 ,'-0 ,'-D ';'-0 , -° °' o 5' / 8'-0 , -0 1 -0 4'-0 5'-0 7'-11: L Z v70 12\ ----------------_ 21 NOT TO SCALE �° - cig 17 18 � z �poz� Y SB-5 0 = ZN j O 608 a Z �~ wvlQim 805 qo 69210 o Z O 0 aM rN-I- 0 5'-7' 4'-10% 8' N'/: o W O Z a\Ll7Q 8 609 612 16 I AUTOMATIC Hydraulic Information Remcle Areal i. 602 m 9?10 1 FIRE PROTECTION OCCUPANCY CLASSIFICATION ESFR 0 5'-1'/z' '-10'/z 8' ' 8' 1 -0 -0 4'-8 4 B' 'A.0'-6 -7 1 1 MIN.END HEAD PRESSURE 52.000(ESFR) N 6 604 607 611 14 SYSTEMS,INC. TOTAL HOSE STREAMS 250.00 3 a 4* ® 4 4 5 TOTAL HEADS FLOWING 12 2'-0 K-FACTOR 16.8 ? v 2 TOTAL WATER REQUIRED 1727.11 45'-1'/z 3 City of Arlington TOTAL PRESSURE REQUIRED 62.080 1 601 603 Bg6 0' 'a -0 1 -0 , -0 4'-8 BuildingDepartment BASE of RISER(gpm) 1477.1, u p BASE of RISER(psi) 136.983 APPROVED (p ) ( ) ® ® q w SAFETY MARGIN si +14.094 18.5% O r SYSTEMS Kevin Olander-07/21/2025 2 46'- No changes authorized unless approved by o'-/�'-0 -0 , -0 10.0 s-0 q'-0 -0 z7 1 saa q q saa c�qF c�\o2 PRO1E the Building Official 4" HOLES IN BEAMS FOR BRANCHLINES ' " 15 s 0" 19435 SW 129th AVENUE (B Y OTHERS) ' T % Y 1 - TUALATIN 2-9284 62 X:(50)692-1 2 y ,8 5810 37 7 , 37 FAX:(503)692.1186 46'- OR CCBB D067534 W-•/J'-0 '-0 1 -0 1 -0 4'-8 4 WACCB#AFPSYI'0918Z 4 ,o zo `7 4 _T III, q DRAWN BY: AH ® 2 1 -4 -0 1 DATE: 3/28/25 SYSTEM 1 0'-/>3'- -0 1 .0 -0 4-0 -0 -0 -0 AHJ: City of Arlington 11 22 E / SHEET: 1/8th11= 11-0 19 19 19 FP 2 of 7 AFP.PROJECT q: 25034 GENERALNOTES 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. 3 2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS 73 14 75 16 17 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER z PIPE FROM FREEZING o 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED rn IN ACCORDANCE WITH NFPA-13 O w 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES 2 (WIRING BY OTHERS) I I 1 '-0' R I. EE 10.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. 0' 8'-0 4••7 1 5.5 1'-0 1 -0 1'1-0 1'-0 1'-0 1'1-0 1' 1'-0 1'1-0 1'-0 1'•0 1'1-0 1'•0 1'-0 1 q•-0 1'-0 5'-3 'A 1' -6 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. 15'SYa l I ® I ® b® 4® 4 ® 189 '� BB-71 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) ®- SB-13 SB-13 SB-13 gB-13 SB-13 ® -® gB-13 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS 1 2 ' a 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF 2'-0" HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 0' /. 6'-0 77 5'5 1 -0• 1'-0 1'-0 111.0 1'-o - 1 '-0 1'-0 1'-0 1'-0 1'-0 1'-0 1'-0 1'-0 1'-0 1'-0 11 5'J '-9 1('-0 -6 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. 191 188 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR q q z KEY NOTES 1"2-9/ 0' /, 8'-0 4••7 5'S 1'-0 1'-0 1'-0 1 -o , -o , '-0 1'-0 1'-0 1'•0 1'-0 1'•0 IR 1'-0 1'•0 1'•0 14 1'•0 1'-0 5'S '-9 1'-0 -6 O Denotes Hydraulic Node 190 q 1s7 __- �+ Denotes 4-Way Sway Brace ®� q ;6„`EP m-c-,„F1 ..LE.4,4 .j 3259 'C-H L 1 2 b 188 ,AFP Systems,- S Ij Denotes Lateral Sway Brace 0' '/. V-0 4•-7 5 15 '-0 7'-0 1'-0 1 '-0 t -0 1 '-0 1'-0 1'-0 1'-0 1'-0 1'-0 1'-0 7'-0 1 70 1'-0 1'-0 5'-3 '-9 1'-0 -8 Denotes Longitudinal Sway Brace q 789 q 185 l d 0 FF It Denotes Finished Floor to Center of Pipe ' z z TS Denotes Bottom of Deck to Center of Pipe o i e•-0 W-7 s-5 141.0 TO , -0 , -0 , -o -0 -0 ,'-0 '('.0 ,'-0 ,'•o ,'-0 ,'•0 1'•0 1'-0 0 5'-3 9 -0 8 O1sa q 184 CL B E LL 2 n w w 98.5 'c 6'-0 /•-7 5'-5 - 1'-0 1'-0 1'-0 1'-0 I('-0 1'-0 1'-0 1•-0 1•-0 1'-0 5'.3 '•9 1'-0 -8 LL m U 3 187 183 4i w y q 10 v} 2 u LL 8'-0 4'•7 5'-5 1'-0 10'-0 1 '-0 1'-0 1 -0 1'-0 1'-0 1'•0 1'-0 7'•0 1'-0 1'•0 1'•0 1'•0 1'-0 5'3 '-0 , -0 5 'y 188 182 -p r T c p q a z0 y m n 2 98'S ry q aV-0 4'-7 5'-5 1'0 1'-0 1'0 1 -0 - 7 0 1 '-0 1'-0 1'-0 1'-0 7'-0 7'-0 1 '-0 - 7'-0 1'-0 1'-0 1'-0 5•-3 '-0 1'-0 -8 C Y N 185 181 'L 0 rL :`M o q Q) 2 O 98'S } 8'-0 4'7 5'-5 1'-0 - 1'-0 1'-0 1 -0 , '-0 1 -0 1'-0 1'-0 1'•0 1'-0 1'•0 1 -0 1'•0 1••0 7'•0 1'-0 T-3 '-0 1'-0 -8 O u N z 184� 180 M w z q M w ® �® y y 2 w gg•.g `w m r 6'-0 4'-7 5'5 1'-0 1'-0 7'-0 1 '-0 1'-0 1'-0 '-0 1'-0 1'-0 1'-0 1'-0 7'-0 7'•0 1'-0 1'-0 ,'-0 s'-3 '-0 '-0 -8 o u z 783 ,59 w }¢ O c q o � r y 98'S m$ a 8'-0 4'•7 5'S 1'-0 1'-0 1'-o , -0 1'-0 1'-0 1'-0 1'-0 1'-0 7'-0 1'-0 - 7'-0 1'•0 1'•0 1'-0 1'-0 5•-3 '-0 1'-0 5 £, U) = 182 158 3 0 x Q 98.5 ILI Q 8'-0 /•-7 5'S 1'-0 1 -0 1'-0 1 •-0 t •-0 - 1 •-0 1'-0 1'-0 1•-0 ,'-0 1 '-a 1 '-o 1•-0 1•-0 1•-0 1'-0 5'J '-0 1'-0 -8 181 157 IR o ®l q q l® w u, 2 = 0' /, V-0 4••7 5'5 1 -0 , -0 , '-0 1'-0 1 -0 1 .0 1 -0 1 -0 , -0 1 •0 1 •0 1 •0 1 -0 5.3 -0 1 -0 -8 0 156 V o q q U H o $ 2 O 1"'-0' N O 0' /. Fo 7-7 5.5 1'-0 1 -0 1•1 1 '-0 - 1 -o 1 -0 1'-0 1'1 1'•0 1'-0 10' '-0 1'•0 1'•0 1'-0 5'-3 'S 1'-0 •8 0 Z p0 179 412 409 406 403 154 V : '-I81 q 4 mo wQ Z 7J7 p0 Z_ F 0 1 2 ' a Z �� wLNi7Qm OZ.-V-0 4•-7 W-5 1 1-0 1•-0 11.1 , -o 1 '-0 , '-0 7'-0 1'-0 7'•0 1'-0 1'-0 1'-0 1'-0 1'-0 1•-0 1'-0 51-3 '-0 1'1 -0 o W 80 178 471 108 405 402 153 ®- q RA2 AUTOMATIC 2ou t 0'-0 FIRE PROTECTION 0' /. V-0 4•-7 5.5 5 1•-0 1'-0 1-o 1-0 1d-o ,•-0 1•-0 1•-0 1•-0 1•-0 1d'-o 1•.0 1•-0 1•-0 1•-0 s•-3 •5 1•0 -6 SYSTEMS,INC. i 177 173 'am 407 4oa 407 ,sz 2 ®2 2 aid 1 178 172 1 a m c E 2 z m z 3 SYSTEMS 0 V-0 4•-7 5'-5 c 2 15'Sh 175 171 ® q q HF PROTEG 2 2 m z City of Arlington 0 8'-0 42 q 5'S BuildingDepartment 194353W 129M AVENUE p TO(503)692-9284 62 ,74 170 APPROVED FAX:(503)692.1186 OR CCBO D067534 Hydraulic Information Kevin Olander- 07/21/2025 WACCBOAFPSYI'0918Z Remote Am No changes authorized unless approved by OCCUPANCY CLASSIFICATION ESFR the Building Official DRAWN BY: AH MIN.END HEAD PRESSURE 52.000(ESFR) TOTAL HOSE STREAMS 250.00 DATE: 3/28/25 TOTAL HEADS FLOWING 12 K-FACTOR .8 AHJ: City of Arlington TOTAL WATER REQUIRED 1724.75 SYSTEM 2 61 TOTAL PRESSURE REQUIRED 61.442 SHEET: BASE of RISER(gpm) 1474.75 1/8th11- 1 7-0 BASE of RISER N(p 114.768 F P 3 of 7 SAFETY MARGIN(psi) +14.766(79.4k) AFP.PROJECT#: 25034 GENERALNOTES O 4 ,9 -„ q 0 9' h 8'5'h a '/. 10' 10' 10' 10'- - 10'- -- 10• 10. 10, 8'10'/. , -0 1 -0 1 0 1 -0 1 -0 1 -0 1 .0 5'S 'S 1 q10 5 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. � 1 108 1 1 ® 1 1 ® 83 ` 2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED d 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS 20.7'h b u 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS r ® SB•13 $B-13- ® ® a ® �® 7'-6 SB•73 0 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS r 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER * o'- 9'•h 6'S/. 'h 10' 10' 10' 10' 10'- 10' 70'- 10' 19 11 8'10% 1 -0 1 -0 1 -0 1 -0 1 -0 1 -0 1 •0 5'•8 '•8 1 -0 •8 z PIPE FROM FREEZING o 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13 Y G q w 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES (WIRING BY OTHERS) 10.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. r 1® n 108 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. h 19 -11 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. 0'-1 91411. r5% '/. 10' 10' 10' 10' 10' 10• 10'4 10' 8'10'/, 1 -0 1 -0 10-0 1 -0 1 -0 , -0 , •0 5'•8 'S , -0 -6 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) 105 81 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. r 4 4 4 WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF Z-0• r HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS r 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. 19 -11 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR ➢ 0- W h 8.5/, '/. 10' 10'• 10' 10•- 10'- - 10' 10'- 10' 8.10% 1 •0 1 -0 1 -0 1 -0 1 -0 1 -0 1 •0 5.5 'S 1 -o -6 Z 104 q q 80 r 4 b� 4 ®b q KEY NOTES r r .- O Denotes Hydraulic Node 19 -77 '/: ,0' 10' ,0' 10' 10'- 10' 10 10' 8'10'h 1 -0 1 -0 1 -0 1 -0 , -0 1 -0 , -0 5'S 'S 1 -0 -6 �+ Denotes 4-Way Sway Brace B a ,03 79 .Iaao:o��:�o s:IN..I...s*I•• 6rantlon lzmec 6lewe AFP Sr-,Inc. _ , vOi Level3 a i Ij Denotes Lateral Sway Brace AFPS'09182%-" 1 0'-6 1 9'-Y. 6'-5'/ K 10' 10' t0' 10' 10'. 10' 10'- t0' 8'10'/: 1 -0 1 -0 1 -0 1 -0 J-0 1 -0 1 -0 5'S 'S 1 -0 -6 1------------------- -:--J-- Y Denotes Longitudinal Sway Brace 102 78 N 4 FF It Denotes Finished Floor to Center of Pipe Z r C) C) g TS I Denotes Bottom of Deck to Center of Pipe r 0 914A 6'5% % 10' 10'4 10' 10' 10'. 10' 10'- - 10-4 , -0 1 r101 77 F H 4 -® I I iL m Z 19 -11 w 9'-6 4 - 6'-5% % 10'4 101- 10' 10-41 10 10'- 10'- 10'- 8 10% 1 -0 10-0 1 -0 1 -0 1 -0 it 4 1 -0 5'S .1 1 -0 614 RE 1016 w ry 100 76 iA r r d r N , LL a r m q CO O r 0 9%/ 6'5'h % 10• 10'- ,0' 10'- 10' 10' 10' 10' 8'10% t -0 1 -0 -0 1 -0 1 -0 , -0 - 1 -0 5'-0 'S t -0 6-6 C T i z m O r 99 75 ~ a in r 4 4 8 4 mo y W 629'-414 Y Ii a r Y 19 -11 C 04 9' /. 6'S'/. K ,0' 10'• ,0' 10' 10'� 10'-0 10", 10'- 8'10'/, 1 -0 1 -0 1 -0 110-0 1 -0 1 -0 11.0 T-6 'S 1 -0 -6 ° fn a r � 98 74 iW w 3 t7 a K q ' r r 0 Z 19 -11 s w Q 0'- 914A 6'5'/ % 10' 11'- 10' 10' 10'- 10'-0 10'- 10'- 8'10'/: , -0 1 -0 , -0 1 -0 , -0 , -0 , .0 5'S 'S 1 0 -6 Z p 97 73 Z 4 4 �® y w I i6 m Z 19 -11 > 0'- 9'.h 6'5•/, % 10' 10'- 10' 10' 10'- 10'-0 10'- 10'- 8'10% 1 -0 1 -0 1 -0 1 -0 1 -0 1 -0 1 -0 5'6 'S 1 -0 -6 Q A o � r ~ r 4 4 98 1 01 4 72 w r y V) r T f r 1e -11 y ZZ r .14 9' h 6•-5'/ % ,D' 10'• 10' IW41 10'- 10'-0 10'-0 10-1, 8'10% 1 -0 111-0 IT-0 1 -0 1 -0 -- 1 -0 - 1 -0 5.5 'S18 , -0 0'-6 r 95 71 O r 4 4 �® 4 �O 2 N r r r 19 -,1 O r 0 W /. 6*,S% K 10' 10% 10' 10'-b 10' 10'-0 -0 10' 8'10% 1 -0 , 1 -0 1D'-0 1 -0 , -0 1 -0 T-6 ._61 -0 -6 r 94 112 109 106 103 70 4 c 4 m r Z 0 9' /. 6'5% 10' 101- 10' 10' 10'. 10'-0 _ 10' W10% 1 -0 1 1 -0 1 -0 , -0 , -0 1 -0 s'S 'S , -0 0-6 O Q r 93 111 108 105 102 89 1n r 4 4 �® RA3 4 SB 3 O o VI J O 20-7% 92 110 Z 2 NO - - * 19 -11 0 Z p0 0 9' h 6'S'h =3'-6/ 10'- 10'- ® 0'•0 101-6 _ 10•4 - 10'- - f'= 8'10'h5'S 'S C� O mo wa O 107 104 101 68 z In QO�Z� 91 a z � ZN L/O 2 Ed Z �o CC��N=_ �1 ]0'-0'- 0 123'-7 o W aMry- '/ _ 6'2'/ 3'9'/:L 101- 10'-Q Y li'-b 4'S 10' S'S 1.10 1 -0 1 -0 1 -0 1 -0 1 -0 "_0 1 -0 5'S'/. '•5% 1 -0 -6 d a Z a��Q SB-5 4 90 4 67 i. AUTOMATIC �I 123•a FIRE PROTECTION 6'-2'/a T-9'/:- 10•- 10'-Q 1P-Q 6 • ''-2. 44 10 S•5 '-6 .10 , -0 , -0 , -0 , -0 , -0 , -0 , .0 5'-6 •-5% , .0 5 SYSTEMS,INC. „ ` 88 q 65 I- - .. _ 2 123'-7 _v, 4'-3 1 o'- 5'-0 'S •10 , -0 1 -0 , -0 1 -0 11,0 1 -0 , -0 5.5% '•5'h 10.0 5 Hydraulic Information City REER of Arlington Remote Araa3 as 63 g OCCUPANCY CLASSIFICATION ESFR SYSTEM 4 b Building Department MIN.END HEAD PRESSURE 52.000(ESFR) �v4 0 0 (fir APPROVED TOTAL HOSE STREAMS 250.00 O1N 123'-7 3 SYSTEMS TOTAL HEADS FLOWING 12 y.� 4'-3 10'- W-6 'S -10 1 -0 1 -0 1 -0 10-0 10-0 1 -0 1 -0 5'S/. '•5'/a 1 -0 lS'-6 Kevin Olander-07/21/2025 KFACTOR 16.8 0 02 TOTAL WATER REQUIRED 1711.22 q q 81 T�qF PRO"1EC�\ No changes authorized unless approved by TOTAL PRESSURE REQUIRED 62.938 3B-121 BASE of RISER(gpm) 1461.22 2 19435 SW 129th AVENUE the Building Official 12T TUALATIN,OR 97062 BASE of RISER(psi) 138.IN 4'-3 10'- T-6 'S -10 , -0 10-0 1 -0 10-0 10-0 10-0 1 -0 5'S% '-5'/. 1 -0 -6 (503)692.9284 SAFETY MARGIN(psl) +13.471(17.6°h) FAX:(503)692.1186 4 85 4 82 OR CCB00067534 WA CCB#AFPSYI'0918Z 2 123'-7 6'-2 11. 076 4'3 10'- 5'-6 'S -10 , -0 10-0 10-0 1 -0 , -0 1 -0 1 •0 W-61A '-5% , -0 -6 1 DRAWN BY: AH 87 80 4 4 DATE: 3/28/25 se-s] se-s AHJ: Cityof Arlington SYSTEM 3 - - 2 16 g 123'•7 0'-6 1 9'-Q�% 6'-2Y I'�'-9'2- 101 10'-I 10'-1� 6'-2': Q3'-g'. 1o'-Q 0'-6 4'3 10'j T-6 'S -10 , -0 1 -0 , -0 1 -0 1 -0 1 -0 , -0 5'SVi '-5% 1 -0 -6 �e1 89 86 SHEET: 1/8th"= 11-0 0 ,o 1z 13 FP 4 of 7 AFP.PROJECT#: 25034 SB•14 SB•,5 T IS RIM 135'd'/, 132 ,4 N. 3 % _ - ,93'-8 3'-2 10'-0 6'-7 '5 10'-0 101-0 101-0 101-0 101-0 101-0 10'-0 ,0'-0 '-0 10'-0 10'-0q 10-0 q 10'-0 10'-0 10'-0 74 -0 0'-6 10'- 10'- � 11 SB-11 ` SB•,1 SB•1, I 131 SB•,1 � SB-11 709 I�SB-11 p 1 F TRAPEZE HANGER 4 _ _ _ SB•1 0 JI S83~ P 58-13 SB-13 SB-13 O ~ 15.7% i=SB-13 - S� wo 2 79T-8 Y-2 10•-0 6'-7 'd 101.0 101-0 10'-0 101.0 10'-0 101.0 10•-0 10•-0 '-0 ,0'-0 10•.0 101•0 10'-0 101.0 10'-0 74 101.0 d 0'-0 } 9'-'/: 6'-5'/: 148 _ 130 107 y SB-0 6 w e � 109'-1 ®l ®l �~ 56-9 2 4 106 ,93'-0 T-2 1W_0 6'-7 •d 10'-0 10'-0 10--0 10'-0 10'-0 10•-0 1W_0 101-0 101-0 101-0 10'-0 10'-0 10'-0 10'-0 10'-0 T-0 10•-0 -6 _ i 9'-/ b'-5': Y:: 101- 10. io'- 10'. 10'- 147 129 105 Nall— SB-1 ~ q SB-1 a 2 193'-8 3'-2 10'-0 6'-7 'd 10•-0 10'-0 101-0 101-0 101-0 101-0 101-0 10'-0 101-0 10'-0 101-0 10'-0 101-0 101-0 101-0 7'-4 101-0 -0 6'-5% Y: 101- 10' 101- 10'-1 1,� z qq 146 128 104 99 ®i ®l q 4SB.2 L 2 ,93'-0 Y-2 1W_0 77 'd 1W_0 10'-0 10'-0 101-0 1W_0 101-0 1W_0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 101-0 7'-4 '10--0 -0 "s 6'-5% Y: 70'- 10. - '-------w,� --- O145 127 103 Fiaa:eorecnow�s3aixx.aa sys.exs SB ®-3~ -66-� AFP Sy .Iac 2 lewaA q azsaoe C H 1 ykgSlllla- ,AFPSYI'O9txZ 3 B-un+lew$kwi-.i t�� _ 193'•8 alp,.s i�+ns_=rss1 - ..........................: T-2 10•-0 V-7 '-5 10'-0 1W-0 10'-0 10•.0 10•-0 10•.0 10'-0 10'-0 10•.0 10'-0 10•.0 101•0 10'-0 10'-0 10'-0 TA 10'-0 d 0'-6 I 9'-Y: 6'-5% 144 126 102 N C. 0 o Z w 193•-8 _ ,. ._ _. 3'-2 10'-0 6W '-5 1 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'•0 10'-0 10'-0 10'-0 7'-0 10'-0 -6 0'-6 9'-'4 - 10'- p 43 125 F N ®~ 0 ® ~ q SYSTEM 3 w t 2 W m 1 93'-B _ w T-2 1W_0 6'-7 '-5 10'-0 10'-0 10'-0 10•-0 10'-0 10•-0 1W_0 10'-0 10'-0 10'-0 10•-0 10•.0 10'-0 10•-0 10•-0 7'-4 q 10'-0 -0 10'- 10'- y w 42 124 w q v y � m a H 2 0) " Q - 193'-8 LLO T-2 10'-0 6'-7 'S 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 101-0 101-0 101-0 10'-0 10'-0 1070 10'-0 10'-0 10'-0 T-4 101-0 -6 r T i 141 123 m O N ~ ax y Foul ® q Jo t; 2 F 193'-8 3'-2 10'-0 61 'd 10'-0 10- 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'•0 10'-0 10'-0 10'-0 Td 10'-0 d 1 " 1 C. o r C 140 122 fn iW W 3 2a m O N 2 TJ Z 193'-8 ri w a Y•2 1W_0 6'.7 '-5 10'-0 10'.0 10'.0 10'-0 10'.0 101-0 10'.0 10'.0 101-0 101-0 10'-0 101•0 10'-0 101•0 7 10'-0 -6 '"^ 10'- ip'- Z p 139 121 ? � � ®~ 8g•1 b y w `w m Z ,93'•8 > 3'-2 10'-0 6'-7 '-5 10'-0 10'-0IR -0 -0 10' ,0' 10'-0 10'-0 10'-0 -0 -0 -0 -0 -0,0' 10' 10' 10'-0 10'•0 10' 70' 101-0 TA10'-0 $ 120 a q o r F �1 138 ®1 q w L y H 2 y 193'-0 ZO Y-2 10'-0 6'-7 '-5 10'-0 10'-0 101-0 101-0 10'-0 101-0 101-0 101-0 101-0 101-0 101-0 101•0 101-0 101-0 101-0 T-4 10'-0 -6 �'- 10'- 3 197 119 sea~ ~ a a ~ 2 G 193'-8 G Y-2 10'-0 6'-7 '-5 10'-0 101-0 101-0 107 10'-0 1 -0 10'-0 10'-0 10'-0 1 -0 10,-0 101•0 101-0 101-0 101-0 74 114 1W.0 d W � 135 212 209 208 209 1,8 y q W 0: H Z 2 ,93'.8 V C T-2- 10'-0 6'.7 '-5 10'-0 10'-0 10'-0 10'-0 101-0 1 -0 10'-0 70'-0 10'-0 1 -0 10--0 10'•0 101-0 101-0 101-0 74 70 d p'-6 I— o -I 134 211 208 205 202 117 N o^ a O 4~ SIB-1O N J O O Z VN0 - 0 00 p mOwQ 133 _ 210 207 204 201 ______________ ___ 1,6 O Z O 6 7 8 n a Z w� wnQm Z O VOH 2 0 q 70?'/a a o W 'o oC 0 7'4 2'-8 1W-0 d 0 9' 'A 61 3'-0'/ 101- 10' 10'- 8'-2% 3'S/: 101.110`6 d aZ a�u�iQ GENERAL NOTES KEY NOTES ® ~�" I. I. e m ® AUTOMATIC Denotes Hydraulic Node 2_0 7W4% FIRE PROTECTION 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. 0 74 2'4 101-0 d 0 11 / 6'-2%q 3'-9% 10'- 10' 10'4 6'-2% T-9% 10'- 0'-6 2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED e� SYSTEMS,INC. 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS e� Denotes 4-Way Sway Brace q q 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS Hydraulic Information 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS I1 Denotes Lateral Sway Brace Ramae Area 4 ® ~ ^21-0 SB-9 70?% ca 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER OCCUPANCY CLASSIFICATION ESFR _. PIPE FROM FREEZING MIN.END HEAD PRESSURE 52.000(ESFR) 0 7'-4 ?2-0 10'-0 -0t B 0 9' /. 6'-2'/: ?3'-9': ,0' 10' 10'- • 6'-2Y: 3'-0% 10' -6 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED I Denotes Longitudinal Sway Brace TOTAL HOSE STREAMS 250.00 E51IN ACCORDANCE WITH NFPA-13 TOTAL HEADS FLOWING 12 ALL SYSTEM CONTROL VALVES SHLL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES(WIRING BY OTHERS) FF Denotes Finished Floor to Center of Pipe K-FACTOR 16.810.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. TOTAL WATER REQUIRED 1711.95 2 S�L2 O 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. TOTAL PRESSURE REQUIRED 63.578 70' % SYSTEMS 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. TS(t Denotes Bottom Of Deck t0 Center Of Pipe BASE&RISER(9Pn) 1481.85 9' 6 6'-2% T-9% 10'- 10' 10'- 6'-2% T-9% 10'- 0'-613 SWITCHES ANSPRINKLER YSTEMS D TAMP RILL BE SWITCHOESITORED BY AN OFF-SITE ON CONROL VVALVES(YEOTHERS)ATION INCLUDING FLOW BASE of RISER(psi) 138.808 q PR14.THE EDGE OF ANY JOIST,BRACING,PIPES,EQ.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. SAFETY MARGIN(Pai) •12.821(18J1%) WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS CIt Of Arlin ton e� 7a• % 1 435 SW IN9OR 97062E15OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF 2'-0" Y gHORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 9' / 6'-2^/: 3'-9% 10'- 10' 10'- 6'-2% 3'-9% 10' -6 Iso3)692.92a/ 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. BUIId Ing D@pBCtnl@nt FAX:(503)692.1186 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR APPROVED 4 OR CCBO D067534 WACCBpAFP9VI.0916Z Kevin Olander-07/21/2025 7W4 YNo changes authorized unless approved by 9 iV-2% T-9 10'- 10 10 6'a% T-9% 10 dDRAwN ev: AH the Building Official DATE: 3/28/25 2 a 70?% e-4AHJ: City of Arlington SYSTEM 4 9' /a 6'-2% q'd'/a ,0' 19' ,9'- 6'.2% '?3•.9•a ,0' d SHEET: 1/8th11= 11-0 0 ,o FP 5 of 7 AFP.PROJECT#: 25034 A GENERALNOTES y y 119 2-0'/a 0'-6 18,0 - V-5 1�'7 10' 10' 10' -0 T h 10'-0 10'-0 10•-0 10' 10'-0 - 10'-0 10'-0 8'�/v %- 10'-0 1 -0 -6 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-13,2019 Ed. 2552.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS u 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS r, Emu] 5. �� o 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS 6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS 2 1 9•0, 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER 0'-6 8'-0 5'•5 •-7 10' 10' 10' T /, 10'-0 10'-0 10'-0 10'-0 10'-0 1W_0 10'-0 6'$% % 10'-0 1 -0 $ z PIPE FROM FREEZING o 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLED + 50471 a 254 220 IN ACCORDANCE WITH NFPA-13 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES 0' Lo 10'-0 10'-0 21 5(WIRING BY OTHERS) 282 Sp 26010.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O.11.ALLOUTLETS FROM MAINS ARE WELDED U.N.O. ® 1 ® 1 $- 1 9'" 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. 0 8'-0 5'$ '-7 10' 10' 70' T h 10'-0 10'-0 .... 10'-0 10'-0 - 10•-0 10'-0 r-6/ % 10'-0 1 -0 $ 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) 252 219 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. - 4 4 WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF 2'-0' HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 2 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. 1 -`0% 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR 0'-6 8'-0 5'-5 '-7 10' 10' 10' T h 101-0 101-0 10'-0 10'-0 10'-0 10'-0 10'-0 6'$Y 10`0 1 -0 -6 z 251 2,8 4 1® FSB-21 l 4 KEY NOTES 2 O Denotes Hydraulic Node X 1 9,0 --------------------------- 0 8'-0 5'-5 '-7 10' 10 10' T h 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 6'$'/: '/: 10'-0 1 -0 $ Denotes 4-Way Sway Brace f ee::o;«;'o:s� M pe:CT O 250 2,7 ' Brenton James Stewed '325&Ofi1SC-H Lev AFP AFP Syeleme.Inc. SB-3 $6"1 AFPSY1_10Z ,��, Ir Denotes Lateral Sway Brace 2 eA71 7 9'-0h Denotes Longitudinal Sway Brace a 81-0 5'-5 •-7 10' 10 10 r h 1014 101-0 10'-0 10'-0 10'-0 10'-0 10'-0 6•-6% i 10'-0 11.0 $ 249 216 4) FF It Denotes Finished Floor to Center of Pipe Hydraulic Information O Z Remote Area 6 TS I Denotes Bottom of Deck to Center of Pipe OCCUPANCY CLASSIFICATION ESFR 2 MIN.END HEAD PRESSURE 52.000(ESFR) 1 9 h w 0'-6 8•-0 5'-5 '-7 10' 10•- 10' T /, 101-0 101-0 10'-0 10'-0 10'-0 10'-0 10'-0 V-15 '/: 10'-0 1 -0 $ 6 TOTAL HOSE STREAMS 250.00 £ u TOTAL HEADS FLOWING 12 248 215 F & K-FACTOR 16.8 4 TOTAL WATER REQUIRED 1709.15 $� SB-1- w 'c TOTAL PRESSURE REQUIRED 57.379 2 rL m Z BASE of RISER(gpm) 1459.15 y BASE of RISER(psi) 132.689 0'-6 8'-0 5'$ '-7 10' 10• 10' T /: 10'-0 10'-0 10'-0 10'-0 10•-0 10'-0 10'-0 b•$Y Y: 10'-0 7 -0 $ 10 w SAFETY MARGIN(psi) +19.061(24.9%) 312 311 309 247 214 w � q v yu rn y a N 2 CO LLO 0'-6 8'-0 5'-5 '-7 10' 10' 10' T h 101-0 10'-0 10'-0 10'-0 10'-0 1W_0 101-0 6'-6% % 10'-0 1 -0 z 310 308 305 246 213 ~ ae O y In �® 4 m n ESI R•52.000 �� ry m a RA6 2 M Y rIMP 0'-6 8'-0 5'•5 '-7 10' 10 10' T h 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 8'$'/: ': 10'-0 1 -0 $ C. a o y r C 307 304 302 245 200 II d ~ K O N 2 a Z 1 9'-0'/, s w G 0 8'-0 T-5 '-7 10' 10' 10' T A 10'-0 10'-0 10'-0 10'-0 10•-0 10•.0 10'-0 6'-6 % 10'-0 1 -0 $ Z w 308 303 •Qne 301 244 199 Z n a 4 �® 4 w `w m r 2 Z 1 8'-0/, > 0'-6 8'-0 5'-5 79� •7 10' 10' 10' T h 101-0 101-0 10'-0 10'-0 10'-0 10'-0 10'-0 a `m o w b 1® ® I 4 198 f F y E 2 y Z ZO 0'-6 81-0 T-5 '•7 10' 1. 10• T h 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 10'-0 -- 6'-6% % 10'-0 1 •0 $ Z z42 197 a TH S AREA 0 SLY 4 ~® 2 �` o G 1 92 G 0'-6 8'-0 5'•5 '-7 10' 101 10' /. 10'-0 10'-0 10'-0 1 10'-0 1W_0 10'-0 6•-6 % 10'-0 1'-0 0'-6 W241 `512 508 506 503 196 ur 4 w RA5 Z 2 0 1 9.0 V 0: 0'-6 8'-0 - 5'$ '•7 1Ir 10' 10' h 10'-0 10'-0 10'-0 1 10'-0 - 10'.0 101-0 F-6 % 10'-0 1'.0 0'.6 O Q 2.40 511 508 505 502 195 N 4 4 O © MB-1- N O O 00 0 0 81-0 5'.5 '-7 10' 10' 10' 7' V-11% - 1 4 SB-12 ®1 V OO Q D 239 510 507 504 501 69'•7' 194 Z O poo Z� 0 = Zoo ul c ���`- ® O 193 O a z w� wLNnQm 2 vo 2 zr % o w aR 0°Cc"N'� am o r h 6--11 --1 o,$ a a Z a_u1a` o e-0 s-s 7 10' ,0 5$ $ 224 Hydraulic Information 238 267 Remote Area 5 AUTOMATIC 0 0 �® 2gg OCCUPANCY CLASSIFICATION ESFR 2 MIN.END HEAD PRESSURE 52.000(ESFR) FIRE PROTECTION 21'-0Y 2 T h 6'-11 :v,20'2��, TOTAL HOSE STREAMS 250.00-0TOTAL HEADS FLOWING12SYSTEMS,INC. 0-6 8'-0 5'.5 [-7�_ 10' 10' V-6 '$ K-FACTOR 16.8 2 230 TOTAL WATER REQUIRED 1711.09 3�, 2 TOTAL PRESSURE REQUIRED 57.849 L7i 228 21'-0h T-0h 6'-11 '1 0'$ BASE of RISER(gpm) 1461.09 2 e 222 BASE of RISER(psi) 133.098 .-0 SAFETY MARGIN(psi) +18.562(24.3%) � 0 8'-0 5'$ '-7 10' 10' 5'$ '$ i6-0 C 233 227 O a ®erg 2zs SYSTEMS In ?-0 �qF PRO"1EC� X 0 8'-0 5'$ ••7 10'4 10' S$ '$ IN /� 19435 3W 129th AVENUE 50'11 '+ 232 B5 8 lilt of Arlington TUALATIN,OR 9]062 Y g (511)692.9284 0,6 9'-0 10'-0 10'-0 27 BuildingDepartment FAX:(503)692.1186 261 259 9 257 258 q 234 OR CCB8006]534 ®1 4" HOLES IN BEAMS FOR BRANCHLINES A PROVED 1® 1 3B$ SB$ SB$ ?$ WA CC Bp AFPSYI'0918Z 1 m'•7 10 10 g$ $ $ (BY OTHERS) Kevin Olander-07/21/2025 z3s 229 No changes authorized unless approved by DRAWN BY: AH the Building Official DATE: 3/28/25 �® 2 �® AHJ: City of Arlington SYSTEM 5 0 6 A 0 5'.5 "T -0 231 231 ! 1 SHEET: 1/8th11= 11-0 Z 0 F P 6 of 7 AFP.PROJECT#: 25034 BRANCHLINES TO BE 0-911 BOD GENERAL NOTES L Bracket"&8"MainsLag TRAPEZE HANGER ags«eW SIDE SAMM.5",4" FEED & FLOAT MAINS TO BE 21-911 BOD 6"&8"Mains 8'MAINS 1",2",2.5",4" side Beare 6" & 8" BULK MAINS TO BE TIGHT TO BOTTOM OF BEAMS U.N.O. 1.SYSTEM DESIGNED AND INSTALLED PER NFPA-1 3,2019 Ed. Drive S«aw or Bracket o 2.HANGERS SHALL BE PER NFPA-13,UL LISTED AND/OR FM APPROVED Wood Joist or Bea / Lag Bolt Nut Side Sammy Scr7)7A d 3.SCHEDULE 40 PIPE TO BE USED FOR THREADED FITTINGS 4.SCHEDULE 10 OR FLOW PIPE TO BE USED WITH GROOVED FITTINGS AT 5.ALL WIRING,PAINTING AND PATCHING BY OTHERS6.INSTALL SEISMIC EXPANSION RINGS FOR ANY SPRINKLER HEADS AT LAY-IN-TILE CEILINGS lla e 7.IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE ADEQUATE HEAT TO PREVENT WET SPRINKLER All hread == Table 9.2.2.1(a)Maximum Distance Between Hangers(h-ln.)Thread _ 4"SCH.10 od zoPIPE FROM FREEZING Rod 8.MAIN DRAINS,AUXILLARY DRAINS AND INSPECTOR'S TESTS ARE TO BE PROVIDED AND INSTALLEDZI _ Norninal Pipe Size(in.)IN ACCORDANCE WITH NFPA-13 Swivel Ring f w 9.ALL SYSTEM CONTROL VALVES SHALL BE OF THE INDICATING TYPE WITH TAMPER SWITCHES Pipe pg �1 3/4 1 11/a 11/2 2 21A 3 3IA 4 5 6 8 (WIRING BY OTHERS) Swivel Rin nTa Naiesllnoh `Y"ATR 10.ALL SPRIGS,DROPS AND ARMOVERS ARE 1"SCH.40 PIPE U.N.O. Steel pipe except NA 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 11.ALL OUTLETS FROM MAINS ARE WELDED U.N.O. 12.RIGID COUPLINGS SHALL BE INSTALLED ON ALL GROOVED LINES U.N.O. pip. threaded 13.SPRINKLER SYSTEMS WILL BE MONITORED BY AN OFF-SITE CENTRAL STATION INCLUDING FLOW Swlvel Rin lightwall SWITCHES AND TAMPER SWITCHES ON CONTROL VALVES(BY OTHERS) + Threaded lightwall NA 12-0 12-0 12-0 12-0 12-0 12-0 NA NA NA NA NA 14.THE EDGE OF ANY JOIST,BRACING,PIPES,E.Q.BRACING,HANGERS,LIGHTS LESS THAN 1 FT. Steel pipe WIDE,ETC.,TO BE LOCATED A MINIMUM OF V-2"HORIZONTALLY AWAY FROM ESFR SPRINKLERS Copper tube 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 15-0 15-0 a 15.OBSTRUCTIONS SUCH AS LIGHTS OVER 1 FT.WIDE TO BE LOCATED A MINIMUM OF 2'-0" CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 NA NA NA NA NA HORIZONTALLY AWAY FROM ESFR SPRINKLER HEADS 16.BRANCH LINE HANGERS TO BE LESS THAN 6"FROM TOP OF PIPE TO ATTACHMENT POINT U.N.O. Ductile-iron pipe NA NA NA NA NA NA 15-0 NA 15-0 NA 15-0 15-0 17.MAINTAIN A MINIMUM OF 36"FROM TOP OF STORAGE TO ESFR SPRINKLER DEFLECTOR z NA:Not applicable. HANGING REQUIREMENTS City of Arlington R,x ---------------------------- Building Eo.° Department rMEPROTECTIONSPRINKLER AYATENA V� t 0 APPROVED 'a2es-0"jam<s61aW B AF Sy tb B--H Level3 ,4 ,AFPSvI Irc Kevin Olander-07/21/2025 "� a R,x gL ' n.r,< E�Iw.; W I.,a., BRACING FOR RISERS IN PUMP ROOM TO BE FASTENED TO WOOD No changes authorized unless approved by ` L Rm_L «<x..- JI BACKING @-8-0 AFF AND WITHIN T-0 OF TOP OF RISER the Building Official (BACKING BY OTHERS) i SENSING LINE DETAIL SB36-SEISMIC BRACE CALCULATIONS SB17-SEISMIC BRACE CALCULATIONS SB1 1.25"-SEISMIC BRACE CALCULATIONS SB2-SEISMIC BRACE CALCULATIONS SB3-SEISMIC BRACE CALCULATIONS NTS msm,c a,n m $.I6 il-, ,n SBl] Pmixt r 5611.25' esmrPml•zt a,n rare ama SB2 sm Pr.lxt ,n rxe ame d a Nne.w ' rowing It-- SBl6 SNntlaw r. NFPA 133019 D.wing M%..e SBl] en artl NFPA 13.9019 ra •M1eNran" 581 an are PA 13-2019 ra R•Nmm. SB3 n aw 019 Dmwl gRehm,x E LL Pump Room Bra° y R,.,J4 y ..Asu y all C.naibo, APP'.ral A9enay UL L w Brac.Typ. Rq,/4-WByerm<Ass<mbly Wan-ft.n AIM-Ag.nsr UL L-d Bmca ryP. Latent Agpmv.l Ag.n<y ULUstee Brice Pe wn9itutlinal PPmvel AgexY UL Linw mm w ue l3l Ap,w al.ge wy• UL Ustw H e TSTRUCTURE INFORMAT10NmnI SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS Key Note Size Description Quantity v. „ „1,,, mr m w,N9Ban, Mwel SM J.ww Bwm3«,t w,.we m.,. am1,.1,t a,.Lea " x.am °` J.Lew 1 8" CS&Y Gale Valve w/Tamer Switch 1 .,. .sc=o3B,a oa9 ... x . w=o.3smo.9 PSxLa• . m mMxn n.,N< .r. ..53 NIA AF70s El [°.,. �mII.1i F^a,w< w . = P Leae Onemxi„ x,A W n u035 eH3,1 HPS M3Im L•w orknntl•n A W n. N035 6HPSx 1HP5 9a21m. eaw tat, P a x tB eon PI Att AFo35 axes 1xPs 1B32IM m 2 8" Bufterfly Valve w/Tamper Switch 3 wma w� Le.e g.I.,w,m, Nmx41L.u,mw.m wP„n. ,Fo35 Bxrs,Lv.x.s 1M:Im. L»e 01-I.. -ndI.m PI"M. Amu "w's 1,3331bL , •n •<,P<n lr.sr m Pe . 'c BRACE INFORMATION BRACE INFORMATION aexnnx,n " IL 3 8" Check Valve 2 rxe em , u,.:.^'a.,.,u,,,,,,,m.e,n,w,epaue^P^rnmsawae. rase emir u,snsrNaar<xexmmmemm.,xwra° F^P✓aaeesouams BRACE INFORMATION M � xMzm�< � BRACE INFORMATION xmY`•m(n ^ ^uM xe-aa ma.m,,.m. L• •m BRACE INFORMATION ,rim " m�my.u.^w",.msxw. swa.Pm..a m,•n...w. .wmm„v. Pamm', axmaesanrvc Z Bract Lengtn M,. -- - wP,.•,n.namrcu,m,o-exexwm<n. smyP•m a is .., 4 6" Check Valve 1 mre 10R m.°„ .. . _ ..m, ..re mxaw,s<F^FMrxasa.axB. a e. Uj rxe - �..°. rr.° 30're59°4 w... tl o Me em r Y.FF rare�ngtn xax a<e nnptn xax m"T Z Lu Lu 5 10x8 Concentric Reducer 1 .a. a., r Ion r ... r an g.a1n. °) '.I`o a, a r. Drae, n c 1. i 6 8x6 Concentric Reducer 2 Ma,xxwema Lw . .a. Max 1aeranN La.e Mx xenrenN,Lewin '•� M.x Namm�N L•atl ten Rolm. �m a1 y"�, .N II-1.Leetl 113 b1 m v e 1:m a12 m Ma 3M g ur 7 8" Butterfly Valve w/Tamper"Normally Closed" 1 FASTENER INFORMATION -- - tiff FASTENER INFORMATION "� _ -s°'°•• FASTENER INFORMATION FASTENER INFORMATION K Iz. $ $° Test Headerw/(6)2%"Hose Valves 1 Fastener Name �0 13 w ,°� fazrene.Name LBSn 13 w � ra x.m`. renener Name wA a.s... .„ Festene.Name FASTENER INFORMATION stone,Name N a 9 6" Main Relief Valve 1 x.n.,•..ten 8.. B �•- a.ener en m. AB�o B ,--•_ """` 'm LL Z10 6x8 Waste Cone 1 am,na mammon 51a m,..,"„°.. mm.,,PnaePmmL,amW..m eme,a mmm.n w�n.,n .a ,e,.,b^,,..,".,», ",n°ra", m°n„P,meaaa,amnaa•m" xarm.m.,.°,r°m..,,w^„a.N.m,...m.xw,,,a,A .ae"°,.,"„m.a,•„".^wa,„K a..,P.,„bPmeM mN.nxrMwxr.,ar•mmFxa.,,,,r,.,.roa,me�..P,.,.aa�aro,P �1 r°""°rc. .,..act."",amt a,m,,,n.ro..,•<..,.m.,manw>m,ra,mmwP..mPma,a,amwm O Ms.x•nz•nN Lwtl 3]4 m. Max..n.BnNLaatl 311 Y, x.ev mruaeum^rwm,mmr,m,mNmawuapMMm,3 m,P. 11 8x6 Diesel Fire Pump 1500 GPM @$5 PSI 1 N „ B eetl SPRINKLER SYSTEM LOAD-LCU eenm ` derM m mmxa,,. ~ y SPRINKLER SYSTEM LOAD GLCUCATION rm a Cr'wrlSIaRIN10.ER SYSTEM LOAD CALCULATION IFr"=Cr"W<) C.=0.531 12 1'/." Jockey Pump 1 � Cr=0.531 C,e 0.531 .Lr U,e .mraMia, mP•slr.rtrP• ,a,9w wNPww, wegxM,ee SPRINKLER SYSTEM LOAD 0.531ALCU1ATION(F,,.=C,'w,l Um wmeP, J m w13 Fire Pump Control Panel 1 o,r P min Mmrtrm 9 ,min w.gMmm AIL mr u,x wxaMie, P rtrP 1.9 Wegnxx n Xr. „^. .e,r M°^ m L<9t .g xx a 14 Jockey Pump Control Panel 1 1 M.m BxLe.n. ax�x.n 3.,I. ,t...R. I..Ieet. so"i.e. M1.:.m 1 xax" BaLw Pam BxPs sxn s.,,. 25..,L 23..3Inxl. S,S.,S x. amx.1 :NPS BBar°» 1M.ME.. 39a IaR S•rtrP• ww n° xPSB.r rw. Y li r 3.MIB. ,Mao w. , w, .Nine m ax.s P••I s.n,. MmR z3.a3lnx L.-Y. uO.4oI .Minn, ,<Bm<"„ z„rsmerrm. ,1- 29- 0 15 Double Wall Diesel Fuel Tank 1 .. eN,,wem w.I,M :o.rin9 aN Pr.wwweaxL „M,,,,x, a r16 Alarm Bell on Exterior(by others) 1 :... a.3B IM. x.a m�5q,w.,9M IwJ�Bxrs swelsa 1. :Sri. �231Iu. x.s sxx xnm :.°nM' .o39Iu :WNm Dw.nww,t lw� „ x.wnww,lw,r Bw„x. IZ` xs..a 3 ma1FPq xeammel snsmx Lxa FP. owl•nmN La.n IFP.I xmk LewYrP„ C G 17 10" Supply lBR 1 inn .,.mr IBE s I- S84-SEISMIC BRACE CALCULATIONS SB5-SEISMIC BRACE CALCULATIONS Sea 2.5 LINES-SEISMIC BRACE CALCULATIONS SB7-SEISMIC BRACE CALCULATIONS � 18 6" FDC IBR 1 .mrm.lest .mB rare .m. -J., m • „ rote ame urs .mr Pmlert .- mr. .m< Ill MFFA 19 11/7 Butterball Valve w/Tamper(wiring by others) 1 are Tree 1Nal 019 A oreral Agensr UL,„ne ar.aT,, wt<mI-.19 pa .more oLnnw .,,.P <m 019 0 ..."." uLn.tw a,vPe IaNal 019 APPr.ral Agexr a UL1,Btw v Z 20 2" SCh.40 Pipe Stand vat agency - .T STRUCTURE INFORMATION coral SEISMIC BRACE ATTACHMENTS C Q P STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION m SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS r2 Z 21 Exhaust Piped To Exterior 1 m.m - amn.In a ME.L.r .,. amnant . Adj.tmatl �e � m9°•+ ° m J. e . re ea"J.�, a al.taw wA .m. cail.In Flange mpoxt Fm,ge Lau.n Fx,Me ..tore Z a U°I 22 Tank Vents Piped To Exterior 2 r3 ne.. ,n. wre 1a• , ... n.. n. a,..�a. o.xm.nen wx.L,m Be.m P, n. AF.3S .xPSx1NPS M2Im. r�..• m. m. .,.. y UI UI 23 Floor Drain(by others) ea onenbn.n Pe nma rmeeam .pe An. AFo35 4x.-I''s I.-bf.. as Driemm�Bn a x.mrm m M AFo35 4N-1- 1,333IY. 3gRACE INFORMATION °` e0-Y-n Fe neruxrmBem P.F.Arc. AFo35 4xPsx- 1.333IM. BRACE INFORMATION BRACE INFORMATION ,wwr,rv.e,.,.m:nmmr:",,.,vF.o,,.°arasc amx,•.,wswa.,, BRACE INFORMATION d m 24 Batteries x. .m µwe,.,°'.eatr,^,x.,^"amm'.aw.s<F=P"�°s^ve^e m em er Wm'°.<"°a,n^mmm°mm.'.°"•°wa=t<^P"n,•°:d".^„ a ,re .m r a.,®,..es,ro„^4,° mmmaa,°:<°x•-..ra5°.m.a PUMP ROOM NOTES: M,x n ee.., mLen9tn M.. n _'lI .•..,, .e M" m, V-T�- •`.�^• ,m n ,x n _.=-i�- ••+'• .�., z -FAN 8 LOUVER TO BE INTERLOCKED WITH PUMP CONTROLLER TO ENSURE er °" " c ,m n. ,,,w„ - m y 8 OPERATION WHEN THE ENGINE IS RUNNING(BY OTHERS) , .. v e, . n rim �ySa .a cvmt e, n rrm M a. 1n RB am .rto t. B. A,gle as•9.• am A g as•9.• •-� .4n Le.n Ratl m .oo.� ,- . Le n R e, ,r 30•9. Le at win w .u1 g as•. arc rot vA.w M.. 3.. 10 -DIESEL TANK SHALL BE ELEVATED TO ENSURE THE SUPPLY OUTLET IS .xanMem.Le.a se m a:xo.,.R. �o,N Lone 300 01 .x,r m,m Laae .1z m. M.- . Leae se m w, 0 F 12 ABOVE THE CENTERLINE OF THE ENGINE FUEL TRANSFER PUMP ON THE - FASTENER INFORMATION f r w ENGINE FASTENER INFORMATION +' FASTENER INFORMATION '� s........ wA - FASTENER INFORMATION - = 18 DIESEL SUPPLY VALVE SHALL BE LOCKED IN OPEN POSITION PER NFPA 20 amne.x,me wA „o„„ .`_ -„ atone.Name x1A „a,a -„•, .....N.m. x1A am„a 0 y I -ENGINE EXHAUST&TANK VENTS TO TERMINATE NO CLOSER THAN 10'•0 TO -,x.,. ,n.r.m o..•m= £ = ANY BUILDING OPENING n.Pw,.,m,Na,m a rim n Min m• °n a,.P.m„an."uaa,.�I,ro.Ma,.„nn m• armPmm•w,m.m,m,x°° Tn'8 19 18 -TEST HEADER SERVES AS MEANS OF FORWARD FLOW TESTING OF 'm0' ' "° `"°"`"a°""""°"""'m"" `"°^"°"fAepio°vtiuO°' z - BACKFLOW PREVENTER xxmawnmmmr.m,mmr,mamNm�aexrmM,3amP. x„r,m.ale•act,°"rma,m"°,",aem.,.aa.�em,m,a,aza,9. °i•• rim, O ..,.11 maw^.°a°°.a„n°,�.°,,..»11_11°,,,.,°,°. SPRINKLER SYSTEM LCAD CALCULATION IF,,,=C,+ ,1 SPRINKLER SYSTEMLOAD CALCU TION IF,.=C,'W,1 SPNNKLER SYSTEM LwI Mg.I 0 2, r LI,. amwMm, Rw,w.mP• ww wwmx. rr1-1- LI,. ...rtmlre PIP.BIr.rtrP. L.,9m w•I9nLm Le,=o.s33u_ ,7 w.gnwm r L�.. ,e,=.mu.^ .me s�..mr°. L.•vrn w.�vMm a °, ,a Leno,A •lex.u,e zN.°5,.e� .-B. ,:.ax a,B...e. .3B..I . 1 ,.grow, zx.war n,., w:mR a.P.Iwn 2aB..N. ],B.a.I a se,6 a.Q a: a: > 23Lm.x� �L.ar na, a.n.w" ..mzFiw LmeWFP. w.S Mar x,. ].°,xLle• . .Ia. I o....mr•ma x,. .r PS Faer m. z 1�v.Iu 5B8-SEISMIC BRACE CALCULATIONS SB9-SEISMIC BRACE CALCULATIONS S810-SEISMIC BRAKE CALCULATIONS SB71-SEISMIC BRACE CALCULATIONS w -� --o wr ,n .mr.xam. m ma .< P�r. g.nr. Be,. mlr a,n, .w.x.m.,6 Protest M Pm1.d M rP.q.n M vmien M SB17 eh d -Tap. "`ena 3-2.19 AP�v.I.srcnre uLLi n. �rn 3-:819 pa r°lae-vfe Lsiuta n�.aTwrP. LFt Am3-2g19 Am IM A•.i.m,r. ria ma..TVPe ��A,aI3-2.19 .ow...i AEwn`• ,sLJ- m Z STRUCTUREIINFORMATION SEISMIC BRACEATTACHMENTS tlT STRUCTURE INFORMATIONIn SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION wI SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS O N 15 1 ..m. e, 1j- m.., e • Adj.Lo•tl .s m• e Ice last FIl"g, ins ura In.. Mn.Le,e ..re - amr,ont z. Aal.L.w s n.ss eeaMlma n. .el.Laae O muI lain fle,ge FyA rtirai s"Flange e.eml loin Flange V 24 r,Mae wre w 1a' r n.r. ... (� N o 76 d.1iii-I.. Pe .SWl.e.m PI An. AFws BNF5.1es 1.32Im. d011 w•n Pxa.mN B<am N m. AF.3s 4xsxl xrs .12 M. eo.LmaN, w„Ixl to Be.m MP•Me. AF131 ex -i's .2Im. _ Q 7 9 BRACE INFORMATION w se onentetR veranel to B,.m M n. Afo35 BxPsxlxPs LBrz mf. BRACE INFORMATION w BRACE INFORMATION (,'� `--I Q1 u,.m„maw,xmm"am.,.rw,.m,gascF,xm.w,asmmox. s BRACE INFORMATION auw xa.,mm n,w.°easca xem.as,an ,vM,mww.a,,.mMM,mrN.m"mquc„g..,.•eswrmm ce .root a Mwmwes.x.n,�.",m„",.,,,ra.rucaP",•,.zw,nmL 17C O 3 .se .m.... n mo+� ,-pl� .r..,,. r.L.ngtn M.x n a. n �� .re a Ma. N p 'e �r g t W.xen Z 1._w .. ...° rr.en ., mPm w e .,2. 0 Z o0 2 3 8 nxo,:FASTENER INFORMATION of ex Nor zt.nNrL.•e1an ]33 inn .•�. J axx°FASTENER INFORMATION 'ems 41111, xNx FASTENER INFORMATION a - U O me L < 13 14 ,1 5 saner Nome wA ,...w - seen..xameFASTENER INFORM XTIOM �� ,w .tone.Name NIA s.,..Nam• wA Z N OO Z� P7zo zo Ricm°xa,P",nem.,,",m,,, Z m. m,... Mm m.., „awnxn o ly 'o O oc vr- m,rn,a a r eo ,waroa,em. ° MP„3z.,a n,u.," „m a,u,. ,,,"• Qm.--i SECTION NORTH FACING SPRINKLER SYSTEM LOAD CALCULATION(F,,, " ran r u e w°° ,r me^°omomuwamr mvanm,P m°"ww°,m m,"°^ m,w°mxr°,rictus II - - "a„a�.^ ,rn.�r ° ° ' ::°:,'m °.,;:�� :rt°;,° a a Z a�Lna =C,'w,l .__ /4' 1 Foot a"e ceuaMm^ asCenrPe 531 Ler •rm,h i �NKLER SYSTEM LOAD CALCULATION tFw,.=C,*W,1 �- -� SPRINKLER SYSTEMLuTION rm=C.•W,1 t SPRINKLER SYSTEM LOAD CALCULATION(Fro y'W.1 PUMP ROOM PLAN VIEW .M r. m w.Iw In. a Mtl x, PIPe,n.rtrP• P P « w.gxxLme ,N, ..•r _ PI...`mw531 N,Pm w.IPe, ww.mAlm .xaMx xm�, w.q m w AUTOMATIC (FUEL TANK&ENGINE REMOVED FOR CLARITY) g.gR 23,g„ . g2,2g,. ;,,"o, w q Mm "qM '/:'=1 Foot ...mn1 .m, mMr rain .5.m 2985. m nw Nam .,.. P1, w rim a...n ,1]9wA .,,wx .,T. xI" ax x .x gw.,. ..m, ..Iw. ,.,.2..x FIRE PROTECTION BYPASS REMOVED FOR CLARITY wNM m .wmmw«,M ( ) w x,. .,m, mar<x x, w"qm, .,. M11-1 SYSTEMS,INC. I, . SB32-SEISMIC BRACE CALCULATIONS SB13-SEISMIC BRACE CALCULATIONS 5814-SEISMIC BRACE CALCULATIONS SB35-SEISMIC BRACE CALCULATIONS sin c w.lxt n r m SB32 -j- M S e.-Pr.j." M Br•r.Nam. S014 am c PrB1xt rx••m• 8"TO SYS 3 m.tl PA13-2019 �wlyR� ... SB32 .w . .riot• Mt BM NFPA 133019 w,ng RM,mnr, $B14 ew Drawing R,y.mw J_ 8"FROM PUMP ROOM P LonPtuelnal APPmral Agwry UL-Bd .r.TVP. L 11odln.l APPmr•IAg-V ULUI.d .c.Tyg. Pxerl4-Way BractAsembly Wall.rdd.,, A .1 AS...y ULL,Nd •r•T_ R.,14 mlwu Y .II Co.,11- AFPwvIAq• U-1d �1 e T STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS r STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS STRUCTURE INFORMATIONmbI- SEISMIC BRACE ATTACHMENTS 6"TO SYS 5 �6"TO SYS 4 mr.m B,.m .t BIN. B.xt m 6"TO SYS 2 d / A13 mtl r wl.Lwe ,`WxnM,Ian NA m,ex P x. x ax .1x.x M "'WxmMMn A , =mrLw<.rMw PP.n. .35 BN B.1xBIm cei lmsl FNn9. WA <al lxFt Fl•ng. 8"TO REMOTE RISERS ea Y-1.tlan eI o actin "n. An3o 1.133 w,. eoNn BR era MATIrNa m Ple•An. n2o x 94z ter. B ACE INFORMATION w n q , nu.,w"r BRACE INFORMATION u, ,rcn.,•". wu u m row C � 6"TO SYS 5 _ BRACE INFORMATION BRACE INFORMATION W w,a nr•I,n•w axe mmme,4W m r nao m 0 � W �� .r. .m.r . m m mm,wmxar sin^ m u„n.. rcm m ram. s°, . :mmM.. _. °_ SYSTEMS (j era en ex •`• °��rn,n /L� r•,Mq •a a. •`• cy xe, •• ee Y� (�\ 4 O ..er Wrn an o�Mo'n e•�m 0 215w 11 x W M..ml ar..t,n w m Mw Ner a Nr .e 92a M. xa„o:.L.e �.M .». M., tl Po M -a Me .law IsloIra °FASTENER INFORMATION r `.1 FASTENER INFORMATION HF PROTEO FASTENER INFORMATION 'FASTENER INFORMATION '•"°" _ -+++r mn.r x.m• x1A a'•^' a •ram .tone.x•m. x1A "" ^ .,^ F am^ LwvD B �y 19435 SW129th AVENUE TUALATIN,OR 97062 •�. - rxLe ar x,ma xwxed M.,ww _ Lrzz n .... ..• F ..,.,. ee,mow.ma,r"..nweMrc.a.,.,aaa,>+,.w,u.om„r,.e.w""".vr°", ,,. „ .a.m..nw..,.w..,«,n m. w„nmm, •.,m.rP.r,,.e,.e.*.Mw.n„ (503)692.9284 Pa r.t x re a.D B Nero n,Lme.am.,t s3,4M x.mNe emwamem 3M emaw,w°A, 2"DRAIN ON MANIFOLD m.m FAX:IS 3)692.1186 ••� Mxarmxa.coo^rxm,m^°,^«°rox.e,x^m,u,xrwwi3mzmP,'•rxn mi°'• m,,.nrcl , w wp, n,,s,m.aP,xrw,,.ro,P i61m Lmxoa.oM.IOlxa aze lw. e.... Ed. OR CCB8006]534 Q •+•.."w.. a•m. .soot...,la.a a WA CCBR AFPSVI'09,BZ SPRINKLER SYSTEM LC.-CALCULATION(Fry•L'r PUMP ROOM RISERS 3 REMOTE RISER BANK 4 Mnn 1Nm ax Ca OB31 b.n -I.- Y.-S. U. •,w". xwI n,g uTIDNLFo"a�•'w 10Bn ,., � ,.a. I x.M P.tw m BNBxx m1. ..R ...LIM w1A.�. 1...]..I � xm �., t x Mbe s.,rtyw Lr,pm gm4lm r�M M txxnwe, nw RmMw Nrmw wegmat gq xe.x, ,I.wR,M .tr w.gMxt w.gnvLln. AH N Eeer Fm. m o on r%ewo w.Iem. r:.qM DRAWN BY: /4"=1 Foot /:'=1 Foot „rE..x.M aAN. DATE: 3/28/25 mre..aWw PS S,wISrBm 23,. 3.131 gym. �,n .S S,w Srn,. ]s n. ,:a,IM. .Rr..r.ww LY• PUMP ROOM ISO VIEW �'� "' ` '' tea. AHJ: City of Arlington "ALL WIRING BY OTHERS" %"=1 Foot (FUEL TANK&ENGINE REMOVED FOR CLARITY) BRACING CALCULATIONS SHEET: FP7of7 AFP.PROJECT q: 25034 CO® Worldwide www.tyco-fire.com Contacts Model ESFR-17 Early Suppression, Fast Response Pendent Sprinklers 16.8 K-factor General piping, as well as possibly reducing or eliminating the need for a system fire Description pump. =_ Applications for the ESFR-17 Pendent The TYCO Model ESFR-17 Pendent Sprinklers are expanding beyond cur- Sprinklers are Early Suppression, Fast rently recognized installation Stan- `. Response Sprinklers having a nominal dards. For information on research fire K-factor of 16.8. (Ref. Figure 1.) They tests, such as with flammable liquids i+ are suppression mode sprinklers that and aerosols, that may be accept- are especially advantageous as a able to an authority having jurisdic- means of eliminating in-rack sprinklers tion, contact the Technical Services when protecting high-piled storage. department. r. Model ESFR-17 Pendent Sprinklers are primarily used for ceiling-only sprinkler CAMI s protection of, but not limited to,the fol- The Model ESFR-17 Pendent Sprinklers lowing storage applications: described herein must be installed • Most encapsulated or non-encap- and maintained in compliance with sulated common materials including this document, as well as with the cartoned, unexpanded plastics applicable standards recognized by Technical the Approval agency, in addition to • Cartoned, expanded plastics the standards of any authorities having • Uncartoned, unexpanded plastics jurisdiction, such as FM Global. Failure Data to do so may impair the performance • Uncartoned, expanded plastics of these devices. Approvals • Some storage arrangements of The owner is responsible for main- FM Approved rubber tires, roll paper, and aerosols taining their fire protection system VdS Approved and devices in proper operating con- LPCB Approved(094b and 0071) For more specific criteria,refer to Table NYC under MEA 356-01-E A in this data sheet as well as the appli- dition. Contact the installing contrac- CE Certified Certificate of Conformity cable design standard. for or product manufacturer with any 1725-CPR-F0011 The Model ESFR-17 Pendent Sprin- questions. Finish klers provide the system designer In all cases, the appropriate NFPA or Natural Brass with hydraulic and sprinkler place- FM installation standard, or other appli- ment options not presently available cable standard, must be referenced Physical Characteristics to traditional ESFR Sprinklers having to ensure applicability and to obtain Frame .............................Brass complete installation guidelines. The Deflector..........................Bronze a nominal K-factor of 14.0. In particu- Compression Screw.......... Stainless Steel lar, Model ESFR-17 Pendent Sprinklers general guidelines in this data sheet Hook............................. Monel are designed to operate at substan- are not intended to provide complete Strut.............................. Monel tially lower-end head pressures, as i.nstallation criteria. Link Assembly................Solder,Nickel compared to ESFR Sprinklers having ■ Button.............................Brass a nominal K-factor of 14.0.This feature Sprinkler Sealing Assembly.......iu ......... InLCN Ejection Spring............... .. Inconel offers flexibility when sizing system Identification Deflector Nut........................Brass Additional Technical Data Number (SIN) Refer to Table A for additional techni- IMPORTANT cal data. Always refer to Technical Data Refer to Table A for sprinkler identifica- Sheet TFP700 for the "INSTALLER tion number. WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 MAY 2018 TFP315 TFP315 Page 2 of 4 1 7 3/4" NPT 1-1/2" Components: 8 1/2" (38,1 mm) 1 - Frame (12,7 mm) 2 - Deflector NOMINAL 3 Compression 9 MAKE-IN Screw 4 - Hook 6 5 Strut 3-9/16" THERMAL 6 Link Assembly II (90,5 mm) SENSING 7 Button 5 ELEMENT 8 - Sealing WRENCH Assembly 4 FLATS 9 - Ejection Spring 3 TEMPERATURE 2 RATING f1-7/8"(47,6 mm)---] FIGURE 1 MODEL ESFR-17 EARLY SUPPRESSION, FAST RESPONSE PENDENT SPRINKLER, 16.8 K-FACTOR Operation Item Description The fusible link assembly is com- Sprinkler Identification Number(SIN) TY7226 prised of two link halves that are joined together by a thin layer of solder.When K-factor,(gpm/psi'/=)(Ipm/bar'/2) 16.8 gpm/psi'/=(241,9 Ipm/bar'/2) the rated temperature is reached, the 165°F(74°C) solder melts and the two link halves Temperature Rating°F(°C) 214°F(101°C) separate, activating the sprinkler and flowing water. Thread Size 3/4 in.NPT or ISO 7-R 3/4 Sprinkler Orientation Pendent Maximum Working Pressure,psi(bar) 175 psi(12,1 bar) TABLE A MODEL ESFR-17 PENDENT SPRINKLER TECHNICAL DATA TFP315 Page 3of4 Design Storage Type FM Global Criteria The following general guidelines pro- vided for the TYCO Model ESFR-17 Sprinkler Type Storage Pendent Sprinklers can be used for a quick reference. The National Fire Protection Associa- Response Type OR tion(NFPA)and FM Global(FM)provide installation standards that must be used to properly design an automatic System Type Wet sprinkler system utilizing Early Sup- pression, Fast Response(ESFR)Sprin- klers.The guidelines provided by NFPA and FM may differ; consequently, the Temperature Rating°F(°C) 2145 F(101°C) appropriate standard must be used for a given installation. Refer to Table B for Open Frame(i.e., no solid shelves)Single, additional information. Double, Multiple-Row,or Portable Rack Storage Refer to FM 2-0 and 8-9 In all cases, the appropriate NFPA or of Class I-IV and Group A or B Plastics FM installation standard must be ref- erenced to ensure applicability and to Solid Pile or Palletized Storage of Class I-IV and Refer to FM 2-0 and 8-9 obtain complete installation guidelines, Group A or B Plastics since the following general guidelines are not intended to provide complete Idle Pallet Storage Refer to FM 2-0,8-9,and 8-24 installation criteria. Refer to Table B for additional information. In addition to this data sheet, the fol- Rubber Tire Storage Refer to FM 2-0 and 8-3 lowing data sheets describe other TYCO ESFR Sprinklers: Roll Paper Storage Refer to FM 8-21 (Refer to the Standard) • TFP312 Model ESFR-25(TY9226) Flammable/Ignitable Liquid Storage Refer to FM 7-29 K=25.2 Pendent Sprinkler (Refer to the Standard) • TFP313 Aerosol Storage Model ESFR-22 (TY8226) (Refer to the Standard) Refer to FM 7-31 K=22.4 Pendnet Sprinkler • TFP316 Automotive Components in Portable Racks N/A Model ESFR-17(TY7126) (Control mode only;refer to the Standard) K=16.8 Upright Sprinkler N/A-Not Applicable • TFP317 TABLE B Model ESFR-17(TY7223) MODEL ESFR-17 PENDENT SPRINKLERS K=16.8 Pendent Sprinkler COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW • TFP318 Model ESFR-1 (TY6226) Where the depths of the solid structural Maximum Spacing K=14.0 Pendent Sprinkler members, such as beams and stem, 12 ft (3,7 m) for building heights • TFP319 exceed 12 in. (302 mm), install ESFR up to 30 ft(9,1 m) Model ESFR-14 (TY6236) Sprinklers in each channel formed by 10 ft(3,1 m)for building heights greater K=14.0 Pendent Sprinkler the structural members. than 30 ft(9,1 m) • TFP320 Ceiling Slope o Minimum Spacing Model ESFR-17(TY7229) Maximum 2 in.rise for 12 in.run(16.7/o) 8 ft(2,4 m) K=16.8 Pendent Sprinkler Maximum Coverage Area 100 ft2(9,3 m2) Minimum Clearance to Commodity Roof Construction 36 in. (914 mm) Unobstructed or obstructed construc- In some cases, the installation stan- Deflector-to-Ceiling Distance beam and girder. tion,such as smooth ceiling, bar joists, dards permit a greater coverage area. NFPA 6 in. to 14 in. (152 mm to Minimum Coverage Area 356 mm) 64 ft2(5,8 m2)per NFPA 13/FM 2-0 Centerline of Thermal Sensing Element-to-Ceiling Distance FM—See FM 2-0 for Storage Sprinklers. TFP315 Page 4of4 "FITTING SIDE" Care and Lir"ited TOWARDS SPRINKLER Maintenance Warranty 0� FITTING The TYCO Model ESFR-17 Sprinklers For warranty terms and conditions,visit must be maintained and serviced in www.tyco-fire.com. accordance with this section. I� Before closing a fire protection system Ordering main control valve for maintenance procedure WRENCH work on the fire protection system that RECESS it controls,permission to shut down the affected fire protection system must be Contact your local distributor for avail- FIGURE2 obtained from the proper authorities ability.When placing an order, indicate W-TYPE 21 and notify all personnel who may be the full product name and Part Number SPRINKLER WRENCH affected by this action. (P/N). Sprinklers which are found to be Sprinkler Assemblies Installation leaking or exhibiting visible signs of Specify: Model ESFR-17 (TY7226), corrosion must be replaced. K=16.8, Early Suppression, Fast Response Pendent Sprinkler with Automatic sprinklers must never be The TYCO Model ESFR-17 Pendent p (specify) temperature rating, natural Sprinklers must be installed in accor- painted, plated, coated, or other- brass, P/N (specify): dance with this section. wise altered after leaving the factory. Modified sprinklers must be replaced. 165°F(74°C)..................58-445-1-165 General Instructions Sprinklers that have been exposed to 214T(10VC).................58-445-1-214 Avoid damage to the fusible Link corrosive products of combustion, but Special Order Sprinkler Assembly during installation by using have not operated,should be replaced Assemblies with ISO 7-1 Thread only the Frame arms to handle the if they cannot be completely cleaned Connections sprinkler and by using the appropri- by wiping the sprinkler with a cloth or Specify: Model ESFR-17 (TY7226), ate sprinkler wrench. Do not apply by brushing it with a soft bristle brush. K=16.8, Early Suppression, Fast pressure to the fusible Link Assembly. Response Res Pendent Sprinkler with ISO Failure to do so can lead to an unstable Care must be exercised to avoid p p link assembly and premature activation damage to the sprinklers before, 7-1 thread connection, (specify) tem- of the sprinkler. Damaged sprinklers during, and after installation. Sprin- perature rating, natural brass, P/N must be replaced. klers damaged by dropping, striking, (specify): wrench twist/slippage,or the like, must 165°F(74°C)..................58-446-1-165 A leak-tight 3/4 in. NPT sprinkler joint be replaced.Also,replace any sprinkler 214°F(101°C).................58-446-1-214 should be obtained by applying a min- that has a cracked bulb or that has lost Sprinkler Wrench imum-to-maximum torque of 10 to 20 liquid from its bulb. Refer to Installation Specify: W-Type 21 Sprinkler Wrench, ft-lb (13,4 to 26,8 N•m). Higher levels section for additional information. of torque can distort the sprinkler inlet P/N 56-001-0-686 with consequent leakage or impairment The owner is responsible for the of the sprinkler. inspection,testing,and maintenance of their fire protection system and devices Step 1. Install the Model ESFR-17 in compliance with this document, as Pendent Sprinkler in the pendent posi- well as with the applicable standards tion (Ref. Figure 2). of the National Fire Protection Associ- Step 2. With pipe-thread sealant ation, such as NFPA 25, in addition to applied, hand-tighten the sprinkler into the standards of any authorities having the sprinkler fitting. Do not apply pres- jurisdiction.Contact the installing con- sure to the Link Assembly, and handle tractor or product manufacturer with the Model ESFR-17 Sprinkler only by any questions. the Frame arms. Automatic sprinkler systems are rec- Step 3. Wrench-tighten the Model ommended to be inspected, tested, ESFR-17 Sprinkler using only the and maintained by a qualified Inspec- W-Type 21 Sprinkler Wrench (Ref. tion Service in accordance with local Figure 2)and by fully engaging(seating) requirements and/or national codes. the wrench on the sprinkler wrench flats(Ref. Figure 1). Step 4. After installation, inspect the Link Assembly of each Model ESFR-17 Sprinkler for damage. In particular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assembly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a registered trademark of DuPont CO® Worldwide www.tyco-fire.com Contacts Series TY.FRB - 2.89 4.2, 5.6, and 9.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage to corrosive atmospheres. Although General corrosion-resistant coated sprinklers Description have passed the standard corrosion tests of the applicable approval agen- The TYCO Series TY-FRB 2.8,4.2,5.6, cies, the testing is not representativell of all possible corrosive atmospheres. and 8.0 K-factor Upright, Pendent, Consequently, it is recommended that ' and Recessed Pendent Sprinklers the end user be consulted with respect WMi described in herein are quick response,standard coverage, decorative 3 mm to the suitability of these coatings for glass bulb-type spray sprinklers.They any given corrosive environment. The are designed for use in light or ordinary effects of ambient temperature, con- hazard,commercial occupancies such chemical to chemicals, and gas/ as banks, hotels, and shopping malls. chemical velocity, should it the cconso- ered,as a minimum,along with the cor- I� The TY-FRB Recessed Pendent Sprin- rosive nature of the chemical to which I kler, where applicable, is intended for the sprinklers will be exposed. use in areas with a finished ceiling.This An intermediate level version of the recessed pendent sprinkler uses one of i the following Recessed Escutcheons: Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet 1 • A two-piece Style 10 (1/2 in. NPT) TFP356. Sprinkler Guards are detailed or Style 40 (3/4 in. NPT) Recessed in Technical Data Sheet TFP780. -� } Escutcheon with 1/2 in.(12,7 mm)of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from The Series TY--FRB 2.8, 4.2, 5.6,the flush pendent position. and 8.0 K-factor Upright, Pendent, Sprinkler • A two-piece Style 20 (1/2 in. NPT) and Recessed Pendent Sprinklers 0 or Style 30 (3/4 in. NPT) Recessed described herein must be installed Identification Escutcheon with 1/4 in. (6,4 mm) of and maintained in compliance with recessed adjustment or up to 1/2 in. this document and with the applicable Number (S I M (12,7 mm) of total adjustment from standards of the National Fire Protec- the flush pendent position. tion Association (NFPA), in addition to TY1131 . . .Upright 2.8K, 1/2 in. NPT The adjustment provided by the the standards of any authorities having TY1231 . . Pendent 2.8K, 1/2 in. NPT Recessed Escutcheon reduces the jurisdiction. Failure to do so may impair TY2131 . . .Upright 4.2K, 1/2 in. NPT accuracy to which the fixed pipe drops the performance of these devices. TY2231 . . Pendent 4.2K, 1/2 in. NPT to the sprinklers must be cut. The owner is responsible for maintain- TY3131 . . . Upright 5.6K, 1/2 in. NPT Corrosion-resistant coatings, where ing their fire protection system and TY3231 . . Pendent 5.6K, 1/2 in. NPT applicable, are utilized to extend the devices in proper operating condition. TY4131 . . .Upright 8.OK, 3/4 in. NPT life of copper alloy sprinklers beyond The installing contractor or sprinkler TY4231 . . Pendent 8.OK, 3/4 in. NPT what would be obtained when exposed manufacturer should be contacted with any questions. TY4831 . . . Upright 8.OK, 1/2 in. NPT IMPORTANT NFPA 13 prohibits installation of 112 in. TY4931 . . Pendent 8.OK, 1/2 in. NPT Refer to Technical Data Sheet NPT sprinklers with K-factors greater Technical TFP2300 for warnings pertaining to than 5.6 in new construction. They are regulatory and health information. intended for retrofit in existing sprinkler Data systems only. Always refer to Technical Data Approvals Sheet TFP700 for the "INSTALLER UL and C-UL Listed WARNING" that provides cautions FM,LPCB,and NYC Approved with respect to handling and instal- lation of sprinkler systems and com- Refer to Table A and B for complete approval onents. Improper handlin and information including corrosion-resistant pg status. installation can permanently damage a sprinkler system or its compo- Maximum Working Pressure nents and cause the sprinkler to fail Refer to Table C to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 JULY 2018 TFP171 TFP171 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 Deflector* SURFACE 7 Bushing 7 1 7/16" (11,1 mm) --3 NOMINAL 2-1/4" MAKE-IN (57,2 mm) 2 1 2-3/16" 4 (55,6 mm) 1 -- (39,7 mm) 5 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 IN. NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 7/16" 3 7(l 11,1 mm) 2 NOMINAL 2-3/16" MAKE-IN (55,6 mm) 2-3/16" 1-1/2 4 " (55,6 mm) (38,1 mm) _5 ! 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 IN. NPT Discharge Coefficient Poly-Stainless pes i g n K=2.8 GPM/psi'/=(40,3 LPM/bars) Physical Characteristics K=4.2 GPM/psi'/(60,5 LPM/bar!) Frame ............................Bronze Criteria K=5.6 GPM/psi/(80,6 LPM/bar'i) Button................ L316 Stainless Steel* K=8.0 GPM/psi!(115,2 LPM/bar'/) Bulb...............................Glass Compression Screw..... L316 Stainless Steel" The TYCO Series TY-FRB 2.8,4.2,5.6, Temperature Rating Deflector...................Copper/Bronze and 8.0 K-factor Upright, Pendent, Refer to Table A and B Sealing Assembly.Gold Plated Beryllium Nickel and Recessed Pendent Sprinklers are w/TEFLON Finishes 'Type L316 stainless steel(UNS 31603)per ASTM intended for fire protection systems Sprinkler: Refer to Table D A479/479M or Bs EN 1008 wN1.4404. designed in accordance with the Stan- Recessed ■ dard installation rules recognized by GreyAluminu ,Jet Blak,Signal Chrome aced, Operation the applicable Listing or Approval Grey Aluminum,Jet Black,Chrome Plated, or Natural Brass agency, such as UL Listing based on The glass bulb contains a fluid that the requirements of NFPA 13 and FM Physical Characteristics expands when exposed to heat.When Approval based on the requirements Frame ............................Bronze the rated temperature is reached, the of the FM Global Loss Prevention Data Butto g Assembly...Beryllium ...NicBrlass/Coppew/TEFLO fluid expands sufficiently to shatter the Sheets. Use only the style 10,20,30,or SealBulb...............................Glass glass bulb, allowing the sprinkler to 40 Recessed Escutcheon, as applica- Compression Screw.................Bronze activate and water to flow. ble,for recessed pendent installations. Deflector...................Copper/Bronze Bushing(K=2.8) ....................Bronze TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 7/16" 3 (11,1 mm) NOMINA MAKE-NL 2-3/16" 2 (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1 mm) f 5 IL / 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8" (73,0 mm)DIA. — FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ -- — SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 7/16" _—_= 3 1,1 mm) MAKE-INNOMINA 2-3/16" 2 J(1(N 2 (55,6 mm) 4 2-3/16" 1-1/2" (55,6 mm) (38,1�mm) 5 1 — 6* STYLE 10 2-7/8"(73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT of the sprinkler. Do not attempt to com- Series TY-FRB Recessed Pendent Installation pensate for insufficient adjustment in Sprinklers The TYCO Series TY-FRB 2.8,4.2,5.6, the escutcheon plate by under-or over- The Series TY-FRB Recessed Pendent and 8.0 K-factor Upright, Pendent,and tightening the sprinkler. Re-adjust the Sprinklers must be installed in accor- Recessed Pendent Sprinklers must position of the sprinkler fitting to suit. dance with the following instructions: be installed in accordance with this Series TY-FRB Upright and Pendent Step 1.After installing the Style 10,20, section. Sprinklers 30, or 40 Mounting Plate, as applica- General Instructions The Series TY-FRB Upright and ble,over the sprinkler threads and with Do not install any bulb type sprinkler Pendent Sprinklers must be installed pipe-thread sealant applied to the pipe if the bulb is cracked or there is a loss in accordance with the following threads, hand-tighten the sprinkler into of liquid from the bulb. With the sprin- instructions: the sprinkler fitting. kler held horizontally,a small air bubble Step 1.Install pendent sprinklers in the Step 2. Tighten the sprinkler into the should be present.The diameter of the pendent position. Install upright sprin- sprinkler fitting using only the W-Type air bubble is approximately 1/16 in. klers in the upright position. 7 Recessed Sprinkler Wrench (Ref. (1,6 mm) for the 135°F (57°C) and Step 2. With pipe thread sealant Figure 15).With reference to Figure 1 to 3/32 in. (2,4 mm)for the 286°F(141°C) applied to the pipe threads, hand- 4,apply the W-Type 7 Recessed Sprin- temperature ratings.A leak-tight 1/2 in. tighten the sprinkler into the sprinkler kler Wrench to the sprinkler wrench NPT sprinkler joint should be obtained fitti flats. fitting.by applying a minimum-to-maximum Step 3. After the ceiling is installed or torque of 7 to 14 lb-ft(9,5 to 19,0 N•m). Step 3. Tighten the sprinkler into the the finish coat is applied, slide on the A leak tight 3/4 in. NPT sprinkler joint sprinkler fitting using only the W-Type 6 Style 10, 20, 30, or 40 Closure over should be obtained with a torque of Sprinkler Wrench(Ref. Figure 14).With the Series TY-FRB Recessed Pendent 10 to 20 lb-ft(13,4 to 26,8 N•m). Higher reference to Figure 1 to Figure 5,apply Sprinkler and push the Closure over the levels of torque can distort the sprinkler the W-Type 6 Sprinkler Wrench to the Mounting Plate until its flange comes in inlet and cause leakage or impairment sprinkler wrench flats. contact with the ceiling. TFP171 Page 4 of 10 *Temperature rating ** Pipe thread connections per 1 Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" 3 (12,7 mm) NOMINAL T(5 5/16" 2 MAKE-IN 7 mm) 2-1/4" 1-9/16" 4 (57,2 mm) (39,7 mm) 5 6* 3/4" NPT** WRENCH STYLE 30 or 40 FLATS RECESSED 2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 1/2" 3 (12,7 mm) NOMINAL 2 MAKE-IN 2-5/16" (58,7 mm) 4 1-9/16" (57,2 mm) (39,7 mm) 5 6* STYLE 40 2-7/8"(73,0 mm)DIA. — RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,314 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 Deflector Assembly 3 4 - Bulb 7/16 2-1/4" (11,1 mm) (57,2 mm) 2 NOMINAL MAKE-IN * Temperature rating is 2-3/16" 1-9/16" 4 indicated on Deflector. (55,6 mm) i (39,7 mm) ii�5 ** Pipe thread connections \ per ISO 7-1 can be 6 * provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFP171 Page 5 of 10 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) 7 FACE OF mm MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" -rrl � (3,2 mm) ► (3,2 mm) 1 T PTi'. 7 ' MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 IN. NPT 2.8 K-FACTOR, 112 IN.NPT 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/41/4"(6 mm)mm4 (17 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER MOUNTING SPRINKLER PLATE PLATE FITTING FITTING 1/8" (3,2 mm) ► (3,2 mm) ► � Pr T. 2 MOUNTING MOUNTING SURFACE SURFACE 7 CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 IN. NPT 4.2 K-FACTOR, 112 IN.NPT TFP171 Page 6 of 10 2-7/8" DIA. 2-7/8"DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) (57,2 mm) (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE (SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) 1 � PT r � 1 i MOUNTING ' MOUNTING SURFACE SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN.NPT 5.6 K-FACTOR, 112 IN. NPT 2-7/8"DIA. 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE ( SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 IN. NPT 8.0 K-FACTOR, 314 IN. NPT WRENCH RECESS / WRENCH RECESS (END"A" USED FOR 1/2" NPT MODELS) WRENCH RECESS PUSH WRENCH (END"B" USED FOR IN TO ENSURE 3/4" NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 10 Sprinkler Finish5 K- Bulb Liquid Natural Factor Type Temperature Color Brass Chrome Plated Polyester 135°F(57°C) Orange Pendent 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 Upright 200°F(93°C) Green (TY1131) 286°F(141°C) Blue 135°F(57°C) Orange 2.8 Recessed 68 155°F °C Red 1/2 in.NPT Pendent ( ) (TY1231)a 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 1,2,4 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)b 175°F(79°C) Yellow Figure 7 200°F(93°C) Green 135°F(57°C) Orange Pendent 155°F(68°C) Red (TY2231) and 175°F(79°C) Yellow Upright(TY2131) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 Recessed 68 155°F °C Red 1,2 1/2 in.NPT Pendent ( ) (TY2231)a 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)b 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 8 of 10 Sprinkler Finishs K- Bulb Liquid Natural Chrome Lead Factor Type Temperature Color Brass Plated Polyesters Poly-Stainless Coated 135°F(57°C) Orange Pendent(TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,3,5 (TY3 ri 31) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 5.6 Recessed 155°F(68°C) Red 1/2 in. Pendent 175°F(79°C) Yellow 1,2,4,5 1,2 N/Ad NPT (TY3231)a Fiigure 10 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent(TY3231)6 ° °175 F 79 C Yellow 1,2,3,4,5 N/A N/A Figure 11 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Pendent(TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,5 Upright 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 80 Recessed 155°F(68°C) Red 3/4 in. (TY4231)a Pendent 175°F(79°C) Yellow 1,2,5 1,2 N/A NPT Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent(TY4231)6 ° °175 F 79 C Yellow 1,2,3,5 N/A N/A Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Pendent 8.0 (TY4931) 155°F(68°C) Red 1/2 in. and 175°F(79°C) Yellow 1,2,4,5,6 N/A 1,2,5 NPT Upright 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not Available(N/A) 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 9 of 10 Sprinkler Finish K- Type Natural Chrome polyester Lead Coated Factor Brass Plated Pendent(TY1231) and 2.8 Upright(TY1131) 1/2 in. 175 psi(12,1 bar) N/A2 NPT Recessed Pendent(TY1231) Pendent(TY2231) and 4.2 Upright(TY2131) 1/2 in. 175 psi(12,1 bar) N/A NPT Recessed Pendent(TY2231) Pendent(TY3231) and 5.6 Upright(TY3131) 250 psi(17,2 bar) 1/2 in. or 175 psi(12,1 bar)' NPT Recessed Pendent(TY3231) Pendent(TY4231) 175 psi and (12,1 bar) 8.0 Upright(TY4131) 3/4 in. 175 psi(12,1 bar) NPT Recessed Pendent(TY4231) N/A 8.0 Pendent(TY4931) 175 psi 1/2 in. and 175 psi(12,1 bar) (12,1 bar) NPT Upright(TY4831) NOTES 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. 2. Not applicable(N/A). TABLE C MAXIMUM WORKING PRESSURE Care and corrosive products of combustion, but requirements and/or national codes. have not operated,should be replaced Care must be exercised to avoid Maintenance if they cannot be completely cleaned damage to the sprinklers before, by wiping the sprinkler with a cloth or during, and after installation. Sprin- The TYCO Series TY-FRB 2.8,4.2,5.6, by brushing it with a soft bristle brush. klers damaged by dropping, striking, and 8.0 K-factor Upright, Pendent,and Care must be taken to avoid damage wrench twist/slippage,or the like,must Recessed Pendent Sprinklers must be to the sprinklers before, during, and be replaced. Also, replace any sprin- maintained and serviced in accordance after installation. Sprinklers damaged kler that has a cracked bulb or that has with this section. Before closing a fire by dropping, striking, wrench twist/ lost liquid from its bulb. (Ref. Installa- protection system main control valve slippage,or the like, must be replaced. tion Section). for maintenance work on the fire pro- Also, replace any sprinkler that has a Initial and frequent visual inspections of tection system that it controls, obtain cracked bulb or that has lost liquid from random samples are recommended for permission to shut down the affected its bulb. (Ref. Installation Section). corrosion-resistant sprinklers to verify fire protection systems from the proper The owner is responsible for the the integrity of the corrosion-resistant authorities and notify all personnel who inspection,testing,and maintenance of material of construction. Thereafter, may be affected by this action. their fire protection system and devices annual inspections per NFPA 25 should Absence of the outer piece of an in compliance with this document, as suffice.lnspections of corrosion-resis- escutcheon, which is used to cover well as with the applicable standards tant sprinklers are recommended at a clearance hole, can delay sprinkler of the National Fire Protection Asso- close range, instead of from the floor operation in a fire situation. ciation (e.g., NFPA 25), in addition to level per NFPA. Inspection at close Sprinklers which are found to be the standards of any other authorities range can better determine the exact leaking or exhibiting visible signs of having jurisdiction.Contact the install- sprinkler condition and the long-term corrosion must be replaced. ing contractor or sprinkler manufac- integrity of the corrosion-resistant turer regarding any questions. material, which can be affected by the Automatic sprinklers must never be Automatic sprinkler systems are rec- corrosive conditions present. painted, plated, coated, or other- ommended to be inspected, tested, wise altered after leaving the factory. and maintained by a qualified Inspec- Modified sprinklers must be replaced. tion Service in accordance with local Sprinklers that have been exposed to TFP171 Page 10 of 10 P/N 57 — XXX — X — XXX SIN TEMPERATURE SPRINKLER RATINGS FINISH 330 2.8K UPRIGHT(1/2 in. NPT) TY1131 135 135°F(57°C) 1 NATURAL BRASS 331 2.8K PENDENT(1/2 in.NPT) TY1231 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 340 4.2K UPRIGHT(1/2 in. NPT) TY2131 POLYESTER 175 175°F(79°C) PURE WHITE 341 4.2K PENDENT(1/2 in.NPT) TY2231 3 POLYESTER(RAL9010)2 200 200eF(93°C) SIGNAL WHITE 370 5.6K UPRIGHT(1/2 in. NPT) TY3131 4 POLYESTER(RAL9003) 286 286°F(141°C) JET BLACK 371 5.6K PENDENT(112 in.NPT) TY3231 5 POLYESTER(RAL9005)3 390 8.OK UPRIGHT(3/4 in.NPT) TY4131 7 LEAD COATED 391 8.OK PENDENT(3/4 in. NPT) TY4231 9 CHROME PLATED 360 8.OK UPRIGHT(1/2 in. NPT) TY4831 NOTES 1. Available only on TY3131,TY3231,TY4131,and TY4231 2. Eastern Hemisphere sales only. 361 8.OK PENDENT(1/2 In. NPT) TY4931 3. Available in only 2.81K,4.21K,and 8.OK,155°F(68°C)and 200°F(93°C);requires longer lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify") finish, P/N (specify) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Contro�S TEFLON Is a registered trademark of DuPont CO® Worldwide www.tyco-fire.com Contacts Series TY-6 - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage IMPORTANT The TY-B Recessed Pendent Sprinkler, -�- Refer to Technical Data Sheet where applicable, is intended for use in areas with a finished ceiling. It uses a TFP2300 for warnings pertaining to two-piece Style 10(1/2 in.NPT)or Style $ ; regulatory and health information. 40(3/4 in. NPT)Recessed Escutcheon. Always refer to Technical Data The Recessed Escutcheon provides { Sheet TFP700 for the "INSTALLER 1/2 in. (12,7 mm) of recessed adjust- WARNING" that provides cautions ment or up to 3/4 in. (19,1 mm) of total with respect to handling and instal- adjustment from the flush pendent lation of sprinkler systems and com- position. The adjustment provided by ponents. Improper handling and the Recessed Escutcheon reduces the installation can permanently damage accuracy to which the fixed pipe drops a sprinkler system or its compo- to the sprinklers must be cut. nents and cause the sprinkler to fail Corrosion-resistant coatings, where to operate in a fire situation or cause applicable, are utilized to extend it to operate prematurely. the life of copper alloy sprinklers beyond what would be obtained Scan the OR code or enter the URL when exposed to corrosive atmo- in a web browser to access the most spheres. Although corrosion-resistant up-to-date electronic version of this coated sprinklers have passed the document. Data rates ma a I standard corrosion tests of the appli- y pp y' cable approval agencies, the testing is not representative of all possible corrosive atmospheres.Consequently, ■ it is recommended that the end-user be The owner is responsible for maintain- consulted about the suitability of these ing their fire protection system and J coatings for any given corrosive envi- devices in proper operating condi- �■ ronment. The effects of ambient tem- tion. Contract the installing contrac- ■ perature, concentration of chemicals, for or product manufacturer with any and gas/chemical velocity, should be questions. considered as a minimum, along with NFPA 13 prohibits installation of 112 in. the corrosive nature of the chemical to NPT sprinklers with K-factors greater ■ which the sprinklers will be exposed. than 5.6 in new construction. They are • An intermediate level version of the intended for retrofit in existing sprinkler ■ Series TY-B Pendent Sprinkler can be systems only. docs.jci.com/tycofire/tfp151 obtained by utilizing the Series TY-B Sprinkler Pendent Sprinkler in combination with the Model S2 Shield. General Identification The Series 2.8,5.6,and 8.0 K-fac- Numbers (SIN) Description The TYCO Series TY-B 2.8, 5.6, tor, Upright, Pendent, and Recessed TY1151 . . . Upright 2.8K, 1/2 in. NPT and 8.0 K-factor, Upright, Pendent, Pendent Sprinklers described herein TY1251 . . .Pendent 2.81K, 1/2 in. NPT and Recessed Pendent S rin- must be installed and maintained in p compliance with this document,as well TY3151 . . . Upright 5.6K, 1/2 in. NPT klers described herein are standard TY3251 . . .Pendent 5.6K, 1/2 in. NPT response, standard coverage,decora- as with the applicable standards of the tive 5 mm glass bulb-type spray sprin- National Fire Protection Association TY4151 . . . Upright 8.01K, 3/4 in. NPT klers.They are designed for use in light, (NFPA), in addition to the standards of TY4251 . . .Pendent 8.01K, 3/4 in. NPT ordinary, or extra-hazard commercial any other authorities having jurisdiction. TY4851 . . . Upright 8.01K, 1/2 in. NPT occupancies such as banks, hotels, Failure to do so may impair the perfor- TY4951 . . .Pendent 8.01K, 1/2 in. NPT shopping malls, factories, refineries, mance of these devices. and chemical plants. Page 1 of 8 JANUARY 2024 TFP151 TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw _ 7 3 Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 - Bulb 7/16 7 2-1/4" (11,1 mm) 3 (57,2 mm) NOMINAL MAKE-IN 2 *Temperature rating is 7� 12-3/16" 1-9/16" indicated on Deflector. (55,6 mm) 1 (39,7 mm) 4 5 ** Pipe thread connections \ per ISO 7-1 can be 6* provided on special 1/2"NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 'ffN 7/16" 3 (11,1 mm) NOMINAMAKEOMII-NL L/2" 6" Eir mm) 2-3/16" 4 (55,6 mm) ( L 5 6* 1/2" NPT** WRENCH STYLE 10 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" E912 3 (12,7 mm) N — NOMINAL T21/16" 2 MAKE A mm) 2-1/4" 1-9/16 4 (57,2 mm) (39,7 mm) —5 _6* 3/4" NPT** WRENCH STYLE 40 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,314 IN.NPT, STANDARD RESPONSE TFP151 Page 3of8 CEILING PLATE 1 - Frame 5 Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 Deflector* Assembly 3 4 - Bulb (11,1 mm) 57,2 mm NOMINAL ( ) 2 MAKE-IN *Temperature rating is 2-3/16" 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) 1 --- --- 5 ** Pipe thread connections \ 'I per ISO 7-1 can be -6* provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT, STANDARD RESPONSE 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4 (73,0 mm) 3/4"(19,1 mm) 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) " (15,9 6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) 57,2 mm � (57,2 mm) FACE OF ( ) MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE I SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-B 3/4"(19,1 mm) TY B 13/16"(20,6 mm) FIGURE 5 FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 IN. TOTAL ASSEMBLY WITH TWO-PIECE 314 IN. TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN. NPT 8.0 K-FACTOR,314 IN. NPT Technical Finishes Design Sprinkler:See Table E Data Recessed Escutcheon:Signal or Pure White, Criteria Grey Aluminum,Jet Black,Chrome Plated, Approvals or Natural Brass The TYCO Series TY-B 2.8, 5.6, and UL and C-UL Listed Physical Characteristics 8.0 K-factor, Upright, Pendent, and FM,LPCB,and VdS Approved Frame ............................Bronze Recessed Pendent Sprinklers are EAC Approved Button......................Brass/Copper intended for fire protection systems Sealing Assembly..Beryllium Nickel w/TEFLON designed in accordance with the Stan- Note: For complete approval infor- Bulb............... ...Glass mation, including corrosion-resistant Compression Screw.................Bronze dard installation rules recognized by status, see Tables A, B, and C. Deflector......................... Copper the applicable Listing or Approval Bushing(K=2.8).....................Bronze agency, such as UL Listing based on Maximum Working Pressure the requirements of NFPA 13 and FM See Table D Operation Approval based on the requirements Discharge Coefficient of the FM Global Loss Prevention Data K=2.8 gpm/psi'/2(40,3 Lpm/bar'/2) The glass bulb contains a fluid which Sheets. Use only the Style 10 or 40 K=5.6 gpm/psi' (80,6 Lpm/bar!) expands when exposed to heat.When Recessed Escutcheon, as applicable, K=8.0 gpm/psi/2(115,2 Lpm/bars) the rated temperature is reached, the for recessed pendent installations. Temperature Ratings fluid expands sufficiently to shatter the See Tables A,B and C glass bulb, allowing the sprinkler to activate and water to flow. TFP151 Page 4of8 Do not attempt to compensate for The steel rod should be heated only to insufficient adjustment in the escutch- the point it can begin to melt the wax, / eon plate by under- or over-tightening and appropriate precautions need to be WRENCH RECESS the sprinkler. Readjust the position of taken when handling the heated rod in (END"A" USED FOR the sprinkler fitting to suit. order to prevent the installer from being 1/2" NPT MODELS) Series TY-B Upright and Pendent burned. Sprinklers Installation Series TY-B Recessed Pendent The Series TY-B Upright and Pendent Sprinklers Sprinklers must be installed in accor- The Series TY-B Recessed Pendent WRENCH RECESS dance with the following instructions: Sprinklers must be installed in accor- (END"B" USED FOR dance with the following instructions: 3/4" NPT MODELS) Step 1.Install pendent sprinklers in the pendent position. Install upright sprin- Step 1. After installing the Style 10 FIGURE 7 TYPE 7 klers in the upright position. or 40 Mounting Plate, as applicable, over the sprinkler threads and with SPRINKLER WRENCH Step 2. With pipe thread sealant pipe thread sealant applied to the pipe applied to the pipe threads, hand- threads, hand-tighten the sprinkler into tighten the sprinkler into the sprinkler the sprinkler fitting. WRENCH fitting. RECESS Step 3. Tighten the sprinkler into the Step 2. Tighten the sprinkler into the sprinkler p 3. fitting the only the W-T e sprinkler fitting using only the W-Type 7 p g g y yp Recessed Sprinkler Wrench,see Figure 6 Sprinkler Wrench, see Figure 7. 8.With reference to Figure 3 or 4,apply For wax-coated sprinklers, use an the W-Type 7 Recessed Sprinkler 8 or 10 in. adjustable wrench. With wrench to the sprinkler wrench flats. reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench Step 3.After the ceiling is installed or or an adjustable wrench,as applicable, the finish coat is applied, slide on the to the sprinkler wrench flats. Style 10 or 40 Closure over the Series PUSH WRENCH TY-B Recessed Pendent Sprinkler INTO ENSURE Wax Coated Sprinklers and push the Closure over the Mount- ENGAGEMENT When installing wax-coated sprinklers ing Plate until its flange contacts the WITH SPRINKLER with an adjustable wrench,take care to ceiling. WRENCHING AREA prevent damage to the wax coating on the sprinkler wrench flats or frame arms Care and FIGURE 8 and, consequently, exposure of bare W-TYPE 7 RECESSED metal to the corrosive environment: Maintenance SPRINKLER WRENCH • Open the jaws of the wrench suffi- ciently wide to pass over the wrench The TYCO Series TY-B 2.8, 5.6, and Installation flats without damaging the wax 8.0 K-factor, Upright, Pendent, and coating. Recessed Pendent Sprinklers must be The TYCO Series TY-B 2.8, 5.6, and • Before wrench tightening the sprin- maintained and serviced in accordance 8.0 K-factor, Upright, Pendent, and kler, adjust the jaws of the wrench with this section. Recessed Pendent Sprinklers must to contact only the sprinkler wrench Before closing a fire protection system be installed in accordance with this flats. main control valve for maintenance section. • After wrench tightening the sprin- work on the fire protection system General Instructions kler, loosen the wrench jaws before that it controls, obtain permission to Do not install any bulb type sprinkler removing the wrench. shut down the affected fire protection if the bulb is cracked or there is a loss After Installation system from the proper authorities of liquid from the bulb. With the sprin- After installation, complete the and notify all personnel who may be kler held horizontally,a small air bubble following: affected by this action. should be present.The diameter of the Inspect the sprinkler wrench flats The owner must assure that the sprin- air bubble is approximately 1/16 in. and frame arms and retouch (repair) klers are not used for hanging any (1,6 mm) for the 135°F (57°C) to the wax coating whenever the coat- objects and that the sprinklers are only 3/32 in. (2,4 mm)for the 360oF(182°C) ing has been damaged and bare cleaned by means of gently dusting temperature ratings. metal is exposed. with a feather duster; otherwise, non- A leak-tight 1/2 in. NPT sprinkler Retouch the wax coating on the operation in the event of a fire or inad- oint should be obtained b apply- wrench flats b gently applying a vertent operation may result. 1 Y Pp Y- Y 9 Y ing a minimum-to-maximum torque of heated 1/8 in. diameter steel rod Absence of an escutcheon, which is 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain to the damaged areas of wax, to used to cover a clearance, may delay a leak-tight 3/4 in. NPT sprinkler joint smooth it back over areas where the time to sprinkler operation in a fire by applying a minimum to maximum bare metal is exposed. situation. torque of 10 to 20 lb-ft (13,4 to Sprinklers which are found to be 26,8 N•m). Higher levels of torque may leaking or exhibiting visible signs of distort the sprinkler inlet and cause Only retouching of the wax coating corrosion must be replaced. leakage or impairment of the sprinkler. applied to the wrench flats and frame arms is permitted, and the retouching Automatic sprinklers must never be is to be performed only at the time of painted, plated, coated, or other- the initial sprinkler installation. wise altered after leaving the factory. Modified sprinklers must be replaced. TFP151 Page 5of8 Bulb Sprinkler Firl K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyesters Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange Upright 155°F(68°C) Red (TY1151) 2.8 and 175°F(79°C) Yellow 1,2,3 Pendent d 1/2 in. N/A NPT (TY1251) 200°F(93°C) Green d Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Recessed Escutcheon,as applicable 3. Approved by FM Global(FM Approvals) b. 150°F(66°C)maximum ceiling temperature 4. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated c. Frame and deflector only Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL d. Not Applicable(N/A) Listed as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM ADoroved as Corrosion-Resistant Sprinklers TABLE A SERIES TY-B 2.8 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS Bulb Sprinkler Finish5 K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyester Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange N/Ad N/Ad 155°F(68°C) Red 1,2,3,4 1,2,3,4 Upright 175°F(79°C) Yellow N/Ad 1,2,3,4 (TY3151) 1,2,3,4 1,2,3,4 1,2,3,4 Figure 2 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4 1b,2b,31b,4b 11b,2b,3b,4b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange N/Ad 5.6 155°F(68°C) Red 1,2,3,4 1/2 in. Pendent 175°F(79°C) Yellow 1,2,3,4 NPT (TY3251) 1,2,3,4 1,2,3,4,5 Figure 2 200°F(93°C) Green 286°F(141°6) Blue 1b,2b,31b,4b 11b,2b,3b,4b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1,2,3,4 (TY3251)a 175°F(79°C) Yellow N/Ad Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2,4 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Recessed Escutcheon,as applicable 3. Approved by FM Global(FM Approvals) b. 150°F(66°C)maximum ceiling temperature 4. EAC Approved c. Frame and deflector only 5. Where Polyester Coated, Lead Coated,Wax Coated, and Wax-over-Lead Coated d. Not Applicable(N/A) Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over- Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers TABLE B SERIES TY-B 5.6 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 6 of 8 Bulb Sprinkler Firl K-Factor Sprinkler Temperature Liquid Type Rating Color Natural Chrome Polyesters Lead Wax Wax-Over-Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1,2,3,8 1,2,8 (TY4151) 1,2,3,4,6,7,8 1,2,5,8 Figure 3 200°F(93°C) Green 286°F(141°C) Blue 1b,2b,3b,8b 1b,2b,3b,8b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange 1,2,3,4,6,7,8 1,2,3,8 8.0 155°F(68°C) Red 3/4 in. Pendent 175°F(79°C) Yellow 1,2,4,6,7,8 1,2,8 1,2,8 NPT (TY4251) 1,2,5,8 Figure 3 200°F(93°C) Green 1,2,3,8 286°F(141°C) Blue 1,2,3,4,6,7,8 1b,2b,3b,8b 1b,2b,3b,8b 360°F(182°C) Mauve N/Ad 135°F(57°C) Orange 1,2,3,4,8 Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,4,8 N/Ad (TY4251)a Figure 6 200oF(93'C) Green 1,2,3,4,8 286°F(141°C) Blue 1,2,8 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1 2 3 1, , 3, (TY4851)) 4 6 4,6 1,4,� N/Ad Figure 4 200°F(93°C) Green 286°F(141°C) Blue 8.0 360°F(182°C) Mauve N/Ad 1/2 in. NPT 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4951) 1,2,3,4,6 N/Ad Figure 4 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 9. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed 3. Approved by FM Global(FM Approvals) as Corrosion-Resistant Sprinklers;Where Lead Coated,Wax Coated,and Wax-over- 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved 5. Note not used as Corrosion-Resistant Sprinklers 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands, a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Tel.31-53-428-4444/Fax 31-53-428-3377) Recessed Escutcheon,as applicable 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) b. 150°F(66°C)maximum ceiling temperature 8. EAC Approved c. Frame and deflector only d. Not Applicable(N/A) TABLE C SERIES TY-B 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 7 of 8 Sprinkler Finish K-Factor Type Natural Chrome Lead Wax Wax-Over-Lead Brass Plated Polyesters Coated Coated Coated 2.8 Upright(TY1151)and 175 psi(12,1 bar) N/A3 1/2 in. NPT Pendent(TY1251) Upright(TY3151)and 5.6 Pendent(TY3251) 250 psi(17,2 bar)2 1/2 in. NPT or Recessed Pendent 175 psi(12,1 bar) (TY3251) Upright(TY4151)and 175 psi(12,1 bar) 8.0 Pendent(TY4251) 3/4 in.NPT Recessed Pendent (TY4251) 175 psi(12,1 bar) N/A3 8.0 Upright(TY4851)and 175 psi(12,1 bar) 1/2 in. NPT Pendent(TY4951) NOTES 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL)and the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Not Applicable(N/A) TABLE D SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATING 530 2.8K UPRIGHT(1/2 in.NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2 in.NPT) TY1251 3 PURE WHITE(RAL9010)l 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2 in.NPT) TY3151 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2 in.NPT) TY3251 5 JET BLACK(RAL9005)2 200 200°F(93°C) POLYESTER 590 8.OK UPRIGHT(3/4 in.NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141°C)MAX 591 8.OK PENDENT(3/4 in.NPT) TY42516 7 LEAD COATED 360 360°F(182°C) 560 8.OK UPRIGHT(1/2 in. NPT) TY4851 8 WAX-OVER-LEAD 000 OPENS 286-F(141-C)MAX4 561 8.OK PENDENT(112 in. NPT) TY4951 9 CHROME PLATEDS NOTES 1. Eastern Hemisphere sales only 2. Available in only 8.0 K-factor,155°F(68°C)or 200°F(93°C);requires lead time to manufacture 3. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems("OPEN"indicates sprinkler assembly without glass bulb,button,and sealing assembly) 4. Wax-Over-Lead finish not available for TY3151 Upright or TY3251 Pendent 5.6K 1/2 in.NPT 135°F(57°C) 5. Chrome Plated finish not available for TY3151 Upright 5.6K 1/2 in.NPT 135°F(57°C)and 175°F(79°C)or for TY4851 Upright 8.OK 1/2 in.NPT 360°F(182°C) 6. TY4251 in 175°F(79°C)temperature rating not FM Approved,see Table C for all applicable Listings and Approvals TABLE E SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION TFP151 Page 8of8 Sprinklers that have been exposed to Limited Ordering corrosive products of combustion, but have not operated,should be replaced warrant Procedure if they cannot be completely cleaned by wiping the sprinkler with a cloth or For warranty terms and conditions,visit Contact your local distributor for avail- by brushing it with a soft bristle brush. www.tyco-fire.com. ability.When placing an order, indicate Care must be exercised to avoid the full product name and Part Number damage to the sprinklers before, (P/N). during, and after installation. Sprin- Sprinkler Assemblies with klers damaged by dropping, strik NPT- ing, wrench twist/slippage, or the like, pe Thread Connections S must be replaced. Replace any sprin- Specify: Series TY-B (specify SIN), kler that has a cracked bulb or that has (specify factor), (specify Upright lost liquid from its bulb. See the Instal- to Pendent) Sprinkler with (specify) lation Section. temperature rating, (specify) finish or coating, P/N (See Table E) The owner is responsible for the Recessed Escutcheon inspection,testing,and maintenance of Specify: Style (10 or 40) Recessed their fire protection system and devices Escutcheon with (specify*) finish, P/N in compliance with this document, as (specify") well as with the applicable standards of the National Fire Protection Associ- 'Refer toTechnical Data SheetTFP770 ation such as NFPA 25, in addition to Sprinkler Wrenches the standards of any other authorities Specify: W-Type 6 Sprinkler Wrench, having jurisdiction.Contact the install- P/N 56-000-6-387 ing contractor or product manufacturer with any questions. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Automatic sprinkler are recommended to be inspected,tested,and maintained Wax Sticks(for retouching wrench- by a qualified Inspection Service in damaged wax coating) accordance with local requirements Specify: (specify color, below) Color- and/or national codes. coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135T(57'C)......P/N 56-065-1-135 Red for 155T(68'C) .......P/N 56-065-1-155 Yellow for 175T(79'C) .....P/N 56-065-1-175 Blue for 200T(93'C) and 286'F(141'C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F(141°C)sprinklers is the same as for 200°F(93°C)sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F(93°C)sprinkler which is 150°F(66°C). 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 m 2024 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Jol L1nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a trademark of The Ch.--Company FC,LLC CO® Worldwide www.tyco-fire.com Contacts Series EC-8 — 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers The recessed version of the EC-8 IMPORTANT sprinkler, intended for use in areas with Refer to Technical Data Sheet a finished ceiling, uses either of the fol- TFP2300 for warnings pertaining to lowing two-piece escutcheons: regulatory and health information. Always refer to Technical Data • Style 30 recessed escutcheon Sheet TFP700 for the "INSTALLER • Style 40 recessed escutcheon WARNING" that provides cautions The style 30 recessed escutcheon pro- with respect to handling and instal- vides up to 1/2 in. (12,7 mm) of total lation of sprinkler systems and com- adjustment from the flush pendent ponents. Improper handling and position,whereas,the style 40 provides installation can permanently damage 3/4 in. (19,1 mm)of vertical adjustment a sprinkler system or its compo- from the flush pendent position. The nents and cause the sprinkler to fail adjustment provided by the recessed to operate in a fire situation or cause escutcheons reduces the accuracy to it to operate prematurely. which the fixed pipe drops to the sprin- klers must be cut. Scan the QR code or enter the URL Corrosion resistant coatings, where in a web browser to access the most applicable,are utilized to extend the life up-to-date electronic version of this of copper alloy sprinklers beyond that document. Data rates may apply. which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant 1 coated sprinklers have passed the standard corrosion tests of the appli- ■ cable approval agencies,the testing is not representative of all possible cor- 1■ ■1 rosive atmospheres. Consequently, it R is recommended that the end user be 1 consulted with respect to the suitabil- ity of these corrosion resistant coatings ■ for any given corrosive environment. The effects of ambient temperature, Sprinkler 1 concentration of chemicals, and gas/ ■ chemical velocity, should be consid- Identification docs.jci.com/tycofire/tfp223 ered,as a minimum,along with the cor- rosive nature of the chemical to which Number (SIN) the sprinklers will be exposed. General TY4232. . . . . . . . . . . . Pendent, 8.OK Description ® Note:TY4232 is a re-designation for C4232. p The Series EC-8 Extended Coverage The Series EC-8 Extended Coverage Sprinklers described herein must be Pendent Sprinklers are decorative installed and maintained in compliance glass bulb sprinklers designed for use with this document, as well as with the in light hazard occupancies. They are applicable standards of the NATIONAL intended for use in automatic sprin- FIRE PROTECTION ASSOCIATION, in kler systems designed in accordance addition to the standards of any other with standard installation rules such as authorities having jurisdiction. Failure NFPA 13 for a maximum coverage area to do so may impair the performance of 400 ft2 (37,2 m2), as compared to of these devices. the maximum coverage area of 225 ft2 The owner is responsible for main- (20,6 m2)for standard coverage sprin- taining their fire protection system klers used in light hazard occupancies. and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Page 1 of 4 AUGUST 2022 TFP223 TFP223 Page 2 of 4 Sprinkler Firl Hazard Type Temp. Bulb Liquid Natural Chrome Polyester" brass Plated Light 135°F(57°C) Orange Pendent 1,2,3,5 155°F(68°C) Red Refer to Table B for UL and C-LIL 135°F 57°C e 1,2,3,5 Sensitivity Rating Rec.Pendent ( ) Orange and w/Style 30 Esc. 155°F(68°C) Red 1,2,5 Refer to Table C for FM Sensitivity Rating Rec.Pendent 135°F(57°C) Orange 1,2,5 w/Style 40 Esc. 155°F(68°C) Red NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by Factory Mutual(FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. 'Frame and Deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Technical Components: 3/4" ESCUTCHEON PLATE 1 - Frame 1JN8MINAL �NPT** SEATING SURFACE Data 2 - Button \ Approvals 3- Sealing Assembly 2 __ } UL and C-UL Listed. 4- Bulb FM Approved 5- Compression } 2-1/8" Screw 3 (54,0 mm) NYC Approved. * 1/2" 6- Deflector Note: For complete approval information 2,7 mm) including corrosion resistant status, see *Temperature rating is 4 1-7/16" Table A. The approvals apply to the service indicated on Deflector. AKE-IN (36,5 mm) conditions indicated in the Design Criteria 5 section. **Pipe thread II Maximum Working Pressure connections per ISO 6 175 psi(12,1 bar) 7-1 can be provided on special request. Pipe Thread Connection FIGURE 1 3/4 in.NPT SERIES EC-8(TY4232) Discharge Coefficients EXTENDED COVERAGE PENDENT SPRINKLER K=8.0 gpm/psi'/ (115,21pm/bar'/2) (including bar joists) with a maxi- Temperature Ratings Design mum pitch of one in six as defined 135°F(57°C) Criteria and permitted by NFPA 13. 155°F(68°C) 3. The minimum allowable spacing Note:For approval information,see Table A. The Series EC-8 Extended Cover- between the Series EC-8 Sprin- age Pendent Sprinklers must only klers, to prevent cold soldering, is Finish be installed in accordance with the 8 ft(2,4 m). Sprinkler:See Table A applicable UL and C-UL Listing or FM Recessed Escutcheon:Natural Brass, Approval requirements as indicated 4. The Series Sprinklers are Signal White,Chrome Plated below. Only a style 30 or 40 recessed to be installedd in n accordance with escutcheon is to be used for recessed all other requirements of NFPA 13 Physical Characteristics for extended coverage pendent Installation, as applicable For more Frame ............................Bronze information, see Tables A, B, and C. sprinklers. Button............................Bronze Sealing Assembly..Beryllium Nickel w/TEFLON UL and C-UL Listing Requirements FM Approval Requirements Bulb..................... Glass(3 mm dia.) 1. The Series EC-8 Sprinklers may be The Series EC-8 Extended Cover- Compression Screw.................Bronze age Sprinklers are to be installed Deflector...........................Brass used for the coverage areas shown in accordance with the applicable in Table D, based on maintaining Factory Mutual (FM) Loss Prevention Operation the minimum specified flow rate as a function of coverage area and Data Sheet. Information provided in The glass bulb contains a fluid that hazard group for all of the sprin- the FM Loss Prevention Data Sheet ex expands when exposed to heat.When klers in the design area. relate to, but are not limited to, hydrau- lic design, ceiling slope and obstruc- the rated temperature is reached, the 2. With respect to heat sensitivity, the tions, minimum and maximum fluid expands sufficiently to shatter the Series EC-8 Sprinklers can be used allowable spacing, and deflector-to- glass bulb, allowing the sprinkler to with unobstructed construction ceiling distance. activate and flow water. consisting of flat, smooth ceilings TFP223 Page 3of4 Installation Area Style 135'F(57°C) 155'F(68°C) The Series EC-8 Sprinklers must 16 x 16 Pendent QR QR be installed in accordance with this 16 x 16 Style 30 Recessed QR QR section. General Instructions 16 x 16 Style 40 Recessed QR QR Do not install any bulb type sprinkler 18 x 18 Pendent QR QR if the bulb is cracked or there is a loss 18 x 18 Style 30 Recessed QR SR of liquid from the bulb. With the sprin- kler held horizontally,a small air bubble I 18 x 18 Style 40 Recessed QR SR should be present.The diameter of the I 20 x 20 Pendent QR SR air bubble is approximately 1/16 in. (1,6 mm). 20 x 20 Style 30 Recessed QR SR A leak tight 3/4 in. NPT sprinkler joint I 20 x 20 Style 40 Recessed SR SR should be obtained with a torque of NOTES 10 ft-lb to 20 ft-lb (13,4 N•m to 26,8 SR:Quick Response SR:Standard Response N•m). Higher levels of torque may TABLE B distort the sprinkler inlet with conse- SENSITIVITY RATING FOR UL AND C-UL LISTING quent leakage or impairment of the OF SERIES EC-8 SPRINKLERS sprinkler. Do not attempt to compensate for insufficient adjustment of an escutch- I Area Style 135'F(57°C) 155'F(68°C) eon plate by under-or over-tightening I 16 x 16 Pendent QR QR the sprinkler. Re-adjust the position of the sprinkler fitting to suit. I 16 x 16 Style 30 Recessed QR N/A Step 1.The sprinkler must be installed I 16 x 16 Style 40 Recessed N/A N/A with the deflector parallel to the mount- 18 x 18 Pendent QR QR ing surface. Pendent sprinklers must be installed in the pendent position. 18 x 18 Style 30 Recessed QR N/A Step 2. After installing the style 30 or 18 x 18 Style 40 Recessed N/A N/A 40 mounting plate (or other escutch- I 20 x 20 Pendent QR QR eon, as applicable) over the sprinkler pipe threads, and with pipe thread 20 x 20 Style 30 Recessed QR N/A sealant applied to the pipe threads, 20 x 20 Style 40 Recessed N/A N/A hand tighten the sprinkler into the NOTES sprinkler fitting. QR:Quick Response Ste 3.Wrench tighten pendent s rin- SR:Standard Response p 9 P P N/A:Not Applicable klers using only the W-Type 3 (End A) TABLE C Sprinkler Wrench. Wrench tighten the SENSITIVITY RATING FOR FM APPROVAL recessed pendent sprinklers using OF SERIES EC-8 SPRINKLERS only the W-Type 23 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench as shown in Figures Description Area gpm psi 4 and 5 is to be applied to the sprinkler wrench flats as shown in Figure 1. 16 x 16 26 10.6 TY4232(K=8.0) 18 x 18 33 17.0 Care and Pendent 20 x 20 40 25.0 Maintenance NOTES 1 gpm=3.785 Lpm • 1 ft=0.3048 m 1 psi=0.06895 bar • 1 ft2=0.093 m2 1 aom/ft2=40.74 mm/min The Series EC-8 Sprinklers must be TABLE D maintained and serviced in accordance FLOW CRITERIA FOR UL AND C-UL LISTING with this section. OF SERIES EC-8 SPRINKLERS Before closing a fire protection system main control valve for maintenance wise altered after leaving the factory. be replaced. Also, replace any sprin- work on the fire protection system that Modified sprinklers must be replaced. kler that has a cracked bulb or that has it controls,permission to shut down the Sprinklers that have been exposed to lost liquid from its bulb. For informa- affected fire protection systems must corrosive products of combustion, but tion about replacing a sprinkler,see the be obtained from the proper authorities have not operated,should be replaced Installation Section.) and all personnel who may be affected if they cannot be completely cleaned by this action must be notified. by wiping the sprinkler with a cloth or Frequent visual inspections are rec- S rinklers that are found to be leaking by brushing it with a soft bristle brush. ommended to be initially performed p g for corrosion resistant coated sprin- or exhibiting visible signs of corrosion Care must be exercised to avoid klers, after the installation has been must be replaced. damage to the sprinklers before, completed, to verify the integrity of Automatic sprinklers must never be during, and after installation. Sprin- the corrosion resistant coating.There- painted, plated, coated, or other- klers damaged by dropping, striking, after, annual inspections according wrench twist/slippage,or the like, must to NFPA 25 should suffice; however, TFP223 Page 4 of 4 2-7/8" DIA. "FITTING SIDE" 7/16 1/8" (73,0 mm) 1/2"(12,7 rI TOWARDS SPRINKLER (11,1 3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FITTING FACE OF (57,2 mm) SPRINKLER FITTING (3,22 mm) / WRENCH _ 17777-77__ / RECESS (END"A") MOUNTING MOUNTING FIGURE 4 SURFACE PLATE W-TYPE 3 CLOSURE SPRINKLER WRENCH 1-5/16"(33,3 mm) 1-1/16"(27,0 mm) WRENCH �- RECESS FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON h_rr 1 2-7/8" DIA. ; 9/16 1/4" (73,0 mm) 3/4"(19,1 mm) I (14,3 6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) © 0 FACE OF r (57,2 mm) L SPRINKLER 1/81, -- FITTING (3,2 mm) FIGURE 5 W-TYPE 23 RECESSED V — SPRINKLER WRENCH i MOUNTING MOUNTING Sprinkler Assemblies with NPT SURFACE PLATE Thread Connections CLOSURE Specify: Series EC-8 (TY4232), K=8.0, Extended Coverage (Light Hazard) 1-5/16" (33,3 mm) Pendent Sprinkler, (specify) tem- 13/16"(20,6 mm) perature rating, (specify) finish, P/N FIGURE 3 (specify): SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY 135°F(57°C) WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT Natural Brass.............PSN 50-801-1-135 STYLE 40 RECESSED ESCUTCHEON Signal White 03) Polyester ......................PSN 50-801-4-135 Chrome Plated............PSN 50-801-9-135 instead of inspecting from the floor It is recommended that automatic 155°F(68°C) level, a random sampling of close-up sprinkler systems be inspected,tested, Natural Brass.............PSN 50-801-1-155 visual inspections should be made, so and maintained by a qualified Inspec- Signal White(RAL9003) as to better determine the exact sprin- tion Service in accordance with local Polyester ................PSN 50-801-4-155 kler condition and the long term integ- requirements and/or national codes. Chrome Plated............PSN 50-801-9-155 rity of the corrosion resistant coating, Recessed Escutcheon as it may be affected by the corrosive Limited Specify: Style (30 or 40) Recessed conditions present. Escutcheon with (specify*) finish, P/N The owner is responsible for the Warranty (specify") inspection,testing,and maintenance of "Refer to Technical Data Sheet TFP770 their fire protection system and devices For warranty terms and conditions,visit Sprinkler Wrench in compliance with this document, as w`n'w•tyco-fire.com. Specify: W-Type 3 Sprinkler Wrench, well as with the applicable standards P/N 56-895-1-001 of the NATIONAL FIRE PROTECTION Ordering ASSOCIATION such as NFPA 25, in Specify:W-Type 23 Recessed Sprinkler addition to the standards of any other Procedure Wrench, P/N 56-000-6-838 authorities having jurisdiction. The installing contractor or sprinkler man- Contact your local distributor for avail- ufacturer should be contacted relative ability.When placing an order, indicate to any questions. the full product name and Part Number (P/N). 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 m 2022 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Jol L1nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a trademark of The Ch.—a Company FC,LLC VicFlex"" Sprinkler Fittings Series AH2-300 and AH2-CC-300 ✓ctaulicg Braided Flexible Hose Assemblies 10.84 FIexTM 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2-300 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.757140mm straight reducer • AH2-CC-300 1"/DN25 Nominal ID Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.757140mm straight reducer • Sprinkler Reducers: • Sprinkler Connections: 1/2" and 3/4715 and 20 mm • Straight Lengths: 5.75"/140mm, 97230mm, 13"/330mm • 90' Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Inlet Connections: • 1725mm NPT or BSPT • 1" IGS connection ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. 1 Aictaull victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Brackets • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB10 for Armstrong®TechZoneTI ceilings • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm • Style ABBA bracket for suspended, exposed, and hard-lid ceilings • Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature • 2250F/1070C Maximum Working Pressure • 300 psi/2068 kPa Connections • To adapter nipple (inlet) via • 1725.4 mm Grooved IGS • 1725.4 mm NPT or BSPT male thread • To sprinkler head (outlet) via 1/2" or 3/4715 mm or 20 mm Minimum Bend Radius • 87200 mm Maximum Number of Bends per Flexible Drop • See section 5.0 Maximum K-Factor of Sprinkler to be Connected to Reducer • K8.0/11,5 (S.I.) (1/2715mm reducer) • K14.0/20,2 (S.I.) (3/4720mm reducer) 2.0 CERTIFICATION/LISTINGS FM 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaul�c° victaulic.com 3.0 SPECIFICATIONS — MATERIAL Series AH2-300 • Flexible Hose: 300-series stainless steel • Collar/Weld Fitting: 300-series stainless steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc-Plated • Reducers (1/2 or 3/4"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC-300 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2'715 mm or 3/4'720 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Grade"E" EPDM (Type A)Vic-Plue" Pre-lubricated Gasket • EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. Not compatible for use with hot water services or steam services. Note:Reference should always be made to publication 1-100,Victaulic Field Installation Handbook for gasket lubrication instructions. Note:Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to publication 05.01,Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com 4.0 DIMENSIONS Product Details - Series AH2-300 Braided Hose Item Description 1 Flexible Hose 2 Isolation Ring 5 6 3 4 3 Gasket 4 Nut 5 Branch Line Nipple �- A -� 6 Braid B 7 Collar/Weld Fitting Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1220 1073 1220 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC-300 Braided Hose Item Description 5 1 Flexible Hose 1 6 7 3 4 2 Isolation Ring 3 Gasket 4 Nut S Style 108 Coupling 6 Braid A 7 Collar/Weld Fitting B Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 622 757 36 29.5 34.8 915 749 884 48 41.5 46.8 1220 1054 1189 60 53.5 58.8 1525 1359 1494 72 65.5 70.8 1830 1664 1798 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic° victaulic.com 4.1 DIMENSIONS Standard Reducer 5.75"/140 mm straight reducer Optional Reducer 9.0"/229 mm straight reducer --------------------------------- 13.0"/330 mm straight reducer 2.627 2.62"/ 66.5 mm T6.57"/ 4.837 166.9 mm 122.7 mm L) i Short 90'elbow reducer Long 90'elbow reducer NOTE • The Short 90'elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic° victaulic.com 4.2 DIMENSIONS WcRex Brackets 3 Style ABl • Suspended Ceilings • Hard-Lid Ceilings ' Item Description 1 24"/610mm or 48"/1219mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 End Bracket 3 Style A132 3 ° B • Hard-Lid Ceilings Item Description ° 1 24"/610mm or 48'/1219mm Square Bar' 2 Patent-Pending Adjustable Center bracket 3 End Bracket(adjustable) e Style AB3 • Surface Mount Applications Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system 1 z 3 Item Description 1 24"/610mm or 48'/1219mm Square Bar' 3 2 Patent-Pending Adjustable Center bracket 3 Adjustable End Bracket for Hat Furring Channel 3 Style AB5 • Hard-Lid Ceilings z Item Description 1 24'7610 mm or 48'71220 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 3 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic° victaulic.com 4.2 DIMENSIONS (CONTINUED) WcFlex Brackets Style AB7 • Suspended Ceilings • Hard-Lid Ceilings 2 Item Description 1 24"/610mm or 48"/1219mm Square Bar 2 Patented 1-Beez®Center Bracket 3 End Bracket 3 Style AB7 Adjustable 3 • Suspended Ceilings • Hard-Lid Ceilings z Item Description 1 700mm or 1400mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 End Bracket(adjustable) 3 Style AB8 • Hard-Lid Ceilings 2 Item Description 1 I 700 mm or 1400 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 0 Style AB10 • Suspended ceilings 3 2 • Armstrong°TechZone" 1 ® 3 Item Description s 1 6'/152mm Square Bar' 2 Patented 1-Beez®Center Bracket 3 End Bracket Style AB12 • Suspended ceilings 2 • Hard-Lid ceilings �•. �.\ ®® Item Description 1 Style AB12 Bracket Body 2 Set Screw 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctaulic° victaulic.com 4.2 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA • Floor-above mount 3 • Cantilever mount • Temporary mount in exposed ceilings z Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar 3 Cap Screw,Serated Flange,M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body ° 5 Cap Screw,Serated Flange,M6 x 1 x 15.24, ° T25 Torx Drive Recessed Style ABMM • Surface mount 2 • Stand-off mount Item Description 1 Style ABMM Bracket Body i 2 Cap Screw,Serated Flange,M6 x 1 x 15.24, T25 Torx Drive Recessed 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic° victaulic.com 4.3 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB1 Bracket / R � A :fied See Chart 28/8760 mm 21M6"/68 mm max.hole max.hole 2"/51 mm 21/s'"/60 mm 4.4"/ min.hole min.hole 113 mm icalTypical ceilinggrid See note ceil 247610 mm or V27 V38 48"/1219 mm on Pendent Center Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4"Max Recess 1/2"Max Recess 3/4"Max Recess 1/2"Max Recess inches inches inches inches mm mm mm mm "R"Minimum 8.0 Bend Radius 203 W,Minimum Required 14.6 16.1 5.8 5.8 Installation 371 409 147 147 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 9 ✓ctaulic° victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket jele A See Chart t 1.87 2'M6"/68 mm 2'/8760 mm 2'/8760 mm # ly 45 mm 2 x 4" ScB2 max.hole max.hole max.hole Stud 21/8760 mm 2751 mm 2751 mm min.hole min.hole min.hole 3.57 I I89 mmI I I 167406 mm�� Finished Stud C/C ceiling 4 + V38 V27 V27 Pendent Sidewall Hose Clearance Chart V2707 V3802 V2709 3/4"1 20mm 1/2"113 mm 3/4!'120mm Max Recess Max Recess Sidewall inches inches inches mm mm mm "R"Minimum 8.0 Bend Radius 203 "A"Minimum Required 12.2 13.6 12.1 Installation 310 345 307 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4"1 20mm 3/4"1 20mm 1/2"113 mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R"Minimum Bend Radius "A"Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctaulic° victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket R A 23/s"/60 mm 211A6"/68 mm See Chart max.hole max.hole 2"/51 mm 23/8760 mm min.hole min.hole 5/8"/15.9 mm Typical Typical finished ceiling tile ceiling face See note 1/8723 mm Typical 16"/406 mm— Typical V27 V38 247610 mm on Center ceiling grid Pendent Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4"Max Recess 1/2'Max Recess 3/4"Max Recess '/2"Max Recess inches inches inches inches mm mm mm mm "R"Minimum 8.0 8.0 _ Bend Radius 203 203 "A"Minimum Required 14.8 16.2 8.0 5.9 Installation 376 411 203 150 Space NOTE Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 11 ✓ctaul;c° victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket R A See Chart Bracket Assembly 21/8'/60 mm 21M6768 mm 21/a"/60 mm Style AB5 2.37 max.hole max.hole max.hole 7 mm 2751 mm 2'/8760 mm 2"/51 mm I I I I min.hole min.hole min.hole n I II u I II II II II II 3.67 2x4" if ii ii 92mm MetalStud u u I �I I s/8^/ Finished 15.9 mm ceiling face 16"/406 mm Drywall Stud C/C V27 V38 V27 Pendent Sidewall Hose Clearance Chart V2707 V3802 V2709 3/4"1 20mm 1/2"113 mm 3/4"1 20mm Max Recess Max Recess Sidewall inches inches inches mm mm mm "R"Minimum 8.0 Bend Radius 203 "A"Minimum Required 12.0 13.7 12.1 Installation 305 348 307 Space Hose Clearance Chart Long Elbow Short Elbow V2707 V3802 V2709 V3802 3/4"1 20mm 1/2'1 13 mm 3/4"1 20mm 1/2"1 13 mm Max Recess Max Recess Sidewall Max Recess inches inches inches inches mm mm mm mm "R"Minimum _ Bend Radius "A"Minimum Required 3.5 4.9 3.6 3.3 Installation 89 124 91 84 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctaulic° victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 28/8760 mm 2"/6'/68 mm Bracket max.hole max.hole Assembly 2751 mm 23/s"/60 mm A Style AB11 min.hole min.hole See Chart 3.0"/ 76 mm ff ff II II MILLI 1.7"/43 mm Finished Typical /8"/15.9 mm ceiling face ceiling grid Typical ceiling tile See Note 247610 mm or V27 V38 4871219 mm on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow "72707 V3802 3/4"1 20mm 1/2"113 mm Max Recess" Max Recess inches inches mm mm "A"Minimum Required 4.0 3.9 Installation 102 99 Space NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctaulic° victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Recessed Sprinkler and Low Profile Short Elbow Straight 5.75"/140mm Reducer M1n1n,,h,d Ceiling Face;! r1%mch/ 29 rnn, II I li II Square bar No minal length 47355 6 Unfinished See Table _T Fi T a) r gth 1%inch/ Ceiling Face Yx A inch/ 2 mm rn 3mm Square bar V�inch/ A' 3mm See Table "B"See Table 'B'See Table `Finished Face of --- LEE Finished Face of Vonch/16- rn 'A-inch/l 6-mm Typical Ceiling Typical Ceiling V2707 I/Y71 2.7 mm MAX.RECESS V2707W/19-MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4119MM 3/4719MM 3/4119MM 3/4719MM 3/47 19MM Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm A Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 Installation Space 101.6 139.7 142.2 182.9 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 2.227 56 mm Op i 3.937 .94"/ loomm 75 mm 3694-,/ 0.287 0 0 1, 100 0 mm 7 mm 10.84 7491 Rev.C Updated07/2019 0 2019 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaul�c° victaulic.com 4.10 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler R C 33/4/ 95.3 mm I 4 s 2 B A ,I 23/8760 mm max.hole 2751 mm min.hole Hose Clearances inches inches inches inches inches Dimension mm mm mm mm mm WallThickness 2 4 6 8 10 "A" 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 Hose Clearance 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 T" 319 402 503 268 351 452 300 402 1 351 300 Bend Radius 8 "R" 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 15 ✓ctaulic° victaulic.com 4.11 DIMENSIONS Branchline clearances Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart A See chart A See chart i FemaleThreaded Weld Outlet No.142 Grooved Weld Outlet 2750 mm 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm Minimum 8 Minimum 8 R Bend Radius 203 R Bend Radius 203 A Min. 11 A 3 6 Min. 13.1 333 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 16 ✓ctaulic° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA FM Series AH2-300 and AH2-CC-300 Braided Hoses Style AB1, AB2, AB3, AB4, ABS, AB7, A137 Adj., ABB, AB1O, AB12, ABBA, ABMM VicFiex Brackets Equivalent Length of Maximum Number Length of Stainless Steel Sprinkler Outlet 1733.7mm of 90'Bends at 8"/200mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches Imperial mm S.I. inches/type feet/meters 31 5.6 1/2"/Straight 13.8/4.2 2 790 8.1 1/2"/90'Elbow 23.5/7.1 36 5.6 1/2"/Straight 16.6/5.1 2 915 8.1 1/2790"Elbow 25.6/7.8 48 5.6 1/2"/Straight 23.4/7.1 3 1220 8.1 1/2"/90°Elbow 30.7/9.3 60 5.6 1/2"/Straight 30.2/9.2 4 1525 8.1 1/2790"Elbow 35.9/10.9 72 5.6 1/2"/Straight 37.0/11.3 4 1830 8.1 1/2"/90°Elbow 41.1/12.5 31 8.0 3/4"/Straight 20.7/6.3 2 790 11.5 3/4"/90°Elbow 20.5/6.2 36 8.0 3/4"/Straight 25.0/7.6 2 915 11.5 3/4"/90°Elbow 24.6/7.5 48 8.0 3/4"/Straight 35.5/10.8 3 1220 11.5 3/4"/90"Elbow 34.7/10.6 60 8.0 3/4"/Straight 39.6/12.1 4 1525 11.5 3/4"/90°Elbow 40.1/12.2 72 8.0 3/4"/Straight 43.5/13.2 4 1830 11.5 3/4"/90°Elbow 45.2/13.7 31 11.2 -3/4"/Straight 17.8/5.4 2 790 16.1 3/4"/90°Elbow 18/5.5 36 11.2 3/4"/Straight 22.2/6.7 2 915 16.1 3/4"/90"Elbow 22.1/6.7 48 11.2 3/4"/Straight 32.9/10.0 3 1220 16.1 3/4"/90°Elbow 32.1/9.8 60 11.2 3/4"/Straight 36.8/11.2 4 1525 16.1 3/4"/90"Elbow 37.1/11.3 72 11.2 3/4"/Straight 40.5/12.3 4 1830 16.1 3/4"/90°Elbow 41.9/12.7 31 14.0 3/4"/Straight 14.9/4.5 2 790 20.2 3/4"/90°Elbow 15.5/4.72 36 14.0 3/4"/Straight 19.4/5.9 2 915 20.2 3/4"/90°Elbow 19.6/5.9 48 14.0 3/4"/Straight 30.3/9.2 3 1220 20.2 3/4"/90"Elbow 29.5/8.9 60 14.0 3/4"/Straight 33.9/10.3 4 1525 20.2 3/4"/90°Elbow 34.1/10.4 72 14.0 3/4"/Strai ht 37.5/11.4 4 1830 20.2 3/4"/90°Elbow 38.6/11.7 FM NOTES: • Series AH2-300 Braided Flexible Hoses have been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5,and 2-8.FM 1637 for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods,per FM 1637.Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE:A 48-inch Series AH2-300 hose installed with two 30'bends and two 90'bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 17 ✓ctaulic° victaulic.com 6.0 NOTIFICATIONS A WARNING _ Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal,adjustment,or maintenance of any Victaulic products. • Wear safety glasses, hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current,applicable National Fire Protection Association(NFPA 13, 13D, 13R,etc.)standards,or equivalent standards,and in accordance with applicable building and fire codes.These standards and codes contain important information regarding protection of systems from freezing temperatures,corrosion, mechanical damage,etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level,operating temperature,chloride level,oxygen level,and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 18 ✓ctaull victaulic.com 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/linearft N/linearm 31/790 0 6 5.2 23 2.6 38 36/915 �9 5.5 25 2.8 40 48/1220 1 2 6.3 28 3.1 46 60/1525 1 5 7.0 31 3.5 51 72/1830 1 8 7.7 34 3.9 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N Ib/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 36/915 p 9 6.4 29 1.6 23 48/1220 1 2 7.2 32 1.8 26 60/1525 1 5 7.9 35 2.0 29 72/1830 1 8 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the following: • Water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler • Bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Min.Allowable Uniform Load Suspension System ft/m Ib/linearft N/linearm Light MP 5.0 75.7 Direct Hung Intermediate 12.0 181.0 Heavy 16.0 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 19 ✓ctaulic° victaulic.com 7.0 REFERENCE MATERIALS — CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends zX Minimum Minimum (Z2X i Minimum bend radius bend radius bend radius I I OR I Minimum I OR I bend radius I I <\90° — \ I \ I , I Minimum Minimum bend radius i Minimum bend radius bend radius I Minimum _ bend radius Minimum I bend radius NOTE • For out-of-plane(three-dimensional)bends,care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB4 I-VicFlex-AB5 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB12 I-VicFlex-ABBA I-VicFlex-ABMM User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10, -VICFLEX-AB4-AB9, or waive any provision of Victaulic Company's standard conditions of sale,installation -VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.84 7491 Rev.C Updated 07/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 20 ✓ctauliic° Firel-ockT"" Installation-Ready" Rigid Couplings ✓ctaulic° Style 009V, Style 009N and Style 109 10.64 Style 009V Style 009N Style 109 Patented Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes • Style 009V: 11/4— 12"/DN32 — DN300 • Style 009N: 11/4— 12"/DN32— DN300 • Style 109: 11/4—47DN32— DN100 Pipe Material • Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses, contact Victaulic • For exceptions, reference section 6.0 Notifications Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) to 365 psi/2517 kPa • Working pressure dependent on material, wall thickness and size of pipe Function • Joins carbon steel pipe with grooved ends conforming to publication 25.01: Victaulic Original Groove System (OGS) Specifications • Provides a rigid pipe joint designed to restrict axial or angular movement Pipe Preparation • Cut or roll grooved in accordance with publication 25.01 2.0 CERTIFICATION/LISTINGS C&us fM OLPCB VdS ( E LISTED APPROVED LPS 1219:Issue 3.1 009N:G4090023 EN 10311 Cert/LPCB Ref.104-1a/36 109:G421013 CPR(EU) No.305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. 1 deictsullid victaulic.com 3.0 SPECIFICATIONS — MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange coating ❑ Red coating (standard for EMEA-I and Asia Pacific) ❑ Optional for Style 009N and 009V: Galvanized per ASTM A123 (Hot Dipped) or ASTM A1059 (Thermo-Diffusion) ❑ Optional for Style 109: Mechanically Galvanized per ASTM B695 (available only in North America and Latin America). Gasket: (specify choice) ❑ Grade "E" EPDM (Type A) Vic-Pluem Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air)fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES • Reference should always be made to publication 1-100,Victaulic Field Installation Handbook for gasket lubrication instructions. • Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to publication 05.01,Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • The gasket pre-lubrication will appear white to slightly amber in color.The color will not impact gasket or coupling performance. Bolts/Nuts: (specify choice) J Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of(imperial) ASTM A449 or (metric) ISO 898-1 Class 9.8 (M10-M16) or Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of(imperial hex nuts) ASTM A563 Grade B or (metric hex nuts) ISO 898-2 Class 10 (M12-M16) or Class 8 (M20 and greater). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn5 finish (imperial) Type III or (metric) Type II. ❑ Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' ' Optional bolts/nuts are available in imperial size only. Coupling Linkage (Style 109 only): High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type III Finish. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctsuliid victaulic.com 4.0 DIMENSIONS Style 009V Two-Bolt Installation-Ready" Coupling Y Z Y Z X X Style 009V Pre-Assembled Style 009V Joint Assembled Size Bolt/Nut Dimensions Actual Maximum Maximum Allow. Pre-Assembled Joint Assembled Approx. Outside Working End Pipe End Weight Nominal Diameter Pressure2 Load2 Separation3 Size X Y X Y Z (Each) inches inches Lbs. inches inches inches inches inches inches inches inches lb DIN mm N I mm mm Qty. mm mm mm mm mm mm kg 1 1/4 1.660 365 790 0.10 3/8 x 2 3.25 4.81 2.88 4.75 2.13 1.7 DN32 42.4 2517 3514 2.54 2 M10 x 51 82 122 74 120 54 0.8 1 1/2 1.900 365 1035 0.10 3/8 x 2 3.50 5.06 3.13 5.00 2.13 1.7 DN40 48.3 2517 4604 2.54 2 M10 x 51 88 128 80 128 54 0.8 2 2.375 365 1617 0.12 3/8 x 21/2 4.06 5.63 3.63 5.63 2.13 2.1 DN50 60.3 2517 7192 3.05 2 M10 x 63 104 142 92 142 54 1.0 21/2 2.875 365 2370 0.12 2 3/8 x 21/2 4.56 6.06 4.06 6.06 2.13 2.2 73.0 2517 1 10542 3.05 1 M 10 x 63 116 154 1 104 154 1 54 1.0 3.000 365 2580 0.12 2 3/8 x 21/2 4.69 6.13 4.19 6.13 2.13 2.3 DN65 76.1 2517 11476 3.05 M10 x 63 120 156 106 156 54 1.0 3 3.500 365 3512 0.12 2 3/8 x 21/2 5.19 6.81 4.63 6.69 2.19 2.6 DN80 88.9 2517 15622 3.05 M10 x 63 132 174 118 170 56 1.2 4 4.500 365 5805 0.17 3/8 x 21/2 6.38 7.94 5.75 7.75 2.25 3.5 DN100 114.3 2517 25822 4.32 2 M10x63 162 202 146 196 58 1.6 5.500 365 8672 0.17 2 1/2 x 3 7.81 9.50 7.19 9.38 2.31 5.6 DN125 1 139.7 2517 1 38574 4.32 1 M12 x 76 198 242 1 182 238 1 58 2.5 6.500 365 12112 0.17 2 1/2 x 3 8.88 10.56 8.19 10.44 2.31 6.3 165.1 2517 53876 4.32 M12 x 76 226 268 208 266 58 2.9 6 6.625 365 12582 0.17 2 1/2 x 3 9.00 10.69 8.31 10.56 2.31 6.3 DN150 168.3 2517 55968 4.32 M12 x 76 228 272 212 268 58 2.9 8.515 365 20712 0.17 2 1/8 x 31/8 11.25 13.63 10.44 13.50 2.81 13.0 216.3 2517 92132 4.32 M 16 x 92 286 346 266 342 72 5.9 8 8.625 365 21326 0.17 2 1/8 x 31/8 11.31 13.75 10.56 13.63 2.81 13.0 DN200 1 219.1 2517 1 94862 4.32 1 M16 x 92 288 350 1 268 346 1 72 5.9 10 10.750 365 33127 0.25 7/8 x 6 14.13 17.50 13.25 17.13 2.94 25.0 DN250 273.0 2517 147358 6.4 2 M22 x 152 358 444 336 434 74 11.5 12 12.750 365 46600 0.25 7/8 x 6 16.38 19.50 15.63 19.25 2.94 30.0 DN300 323.9 2517 207290 6.4 2 M22 x 152 416 496 396 488 74 13.5 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 009V Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Nan-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctsulid victaulic.com 4.1 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling Y Z. Y Z X X 1 I i Style 009N Pre-Assembled Style 009N Joint Assembled Size Bolt/Nut Dimensions Actual Maximum Maximum Allow. Approx. Working End Pipe End Pre-assembled Joint Assembled Weight Outside g P g Nominal Diameter Pressure2 Load2 Separation3 Size X Y X Y Z (Each) inches inches psi lb inches inches inches inches inches inches inches lb DN mm kPa N mm Qty. mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 2 3/8 x 2 3.13 5.00 2.75 5.00 2.00 1.4 DN32 42.4 2517 3514 1 2.54 M10 x 51 79 127 70 127 51 0.6 1 1/2 1.900 365 1035 0.10 2 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 DN40 48.3 2517 4604 2.54 M10 x 51 86 130 76 130 51 0.7 2 2.375 365 1617 0.12 3/8 x 21/2 4.00 5.63 3.50 5.63 2.00 1.9 DN50 60.3 2517 7192 3.05 21 M10 x 63 102 143 89 1 143 51 1 0.9 21/2 2.875 365 2370 0.12 2 3/8 x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 M10 x 63 114 156 102 156 51 1.0 3.000 365 2580 0.12 2 3/8 x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 M10 x 63 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 3/a x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 DN80 88.9 2517 15622 3.05 M10 x 63 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 3/8 x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 DN100 114.3 2517 25822 4.32 2 M10x63 152 200 143 191 54 1.3 4.250 365 5178 0.17 2 3/8 x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23032 4.32 M 10 x 63 143 187 137 187 54 1.4 5 5.563 365 8872 0.17 2 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 1 39464 4.32 M12 x 76 184 235 1 171 232 57 2.3 5.250 365 7901 0.17 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35146 4.32 2 M12 x 76 1 168 229 162 229 57 2.2 5.500 365 8672 0.17 2 1/2 x 3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38574 4.32 M12 x 76 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 1/2 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 55968 4.32 2 M12x83 213 264 200 257 57 2.7 6.250 365 11198 0.17 2 1/2 x 31/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49812 4.32 M 12 x 83 200 254 187 251 57 2.5 6.500 365 12112 0.17 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53876 4.32 2 M12 x 83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 2 5/8 x 4 10.88 13.38 10.25 13.13 2.50 11.4 DN200 219.1 2517 94862 4.32 M16x101 276 340 260 333 64 5.2 8.515 365 20712 0.17 2 5/8 x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.3 2517 92132 4.32 M16 x 101 270 337 260 257 67 5.2 10 10.750 300 27229 0.25 7/8 x 61/2 13.75 17.00 13.25 17.13 2.75 22.6 DN250 273.0 2068 121120 6.40 2 M22 x 165 349 432 337 435 70 1 10.3 12 12.750 300 38303 0.25 7/s x 61/2 16.00 19.00 15.50 19.13 2.75 27.6 DN300 323.9 2068 170380 6.40 2 M22 x 165 1 406 1 483 1 394 1 486 1 70 12.5 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 009N Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctsulid victaulic.com 4.2 DIMENSIONS Style 109 One-Bolt Installation-Ready Coupling Z Z YL Yg Yg YL 1 X - X Style 109 Pre-Assembled Style 109 Joint Assembled Size Bolt/Nut Dimensions Weight Actual Max. Max. Allow. Pipe Pre-Assembled Assembled Outside Work. End End Sep. Approx. Nominal Diameter Press.2 Load2 Maximum3 Qty. Size YL YB X Z YL YB X Z (Each) inches inches psi Lbs. inches inches inches inches inches inches inches inches inches inches lb DIN mm kPa N mm mm mm mm mm m m mm mm mm mm kg 11/4 1.660 365 790 0.10 1 3/8 x 21/4 1.97 2.49 3.17 1.95 1.93 2.59 2.84 1.95 1.5 DN32 42.4 2517 3514 2.54 M10 x 57 50 63 81 50 49 66 72 50 0.7 11/2 1.900 365 1035 0.10 1 3/8 x 21/4 2.13 2.60 3.41 1.95 2.10 2.68 3.07 1.95 1.6 DN40 48.3 2517 4603 2.54 M10 x 57 54 66 87 50 53 68 78 50 0.7 2 2.375 365 1617 0.12 1 3/8 x 21/4 2.32 2.85 3.76 1.98 2.29 2.95 3.45 1.98 1.9 DN50 60.3 2517 7192 3.048 M10 x 57 59 72 96 50 58 75 88 50 0.9 21/2 2.875 365 2370 0.12 1 3/8 x 21/4 2.63 3.09 4.29 1.99 2.61 3.15 3.93 1.99 2.1 73.0 2517 1 10540 3.048 1 IM10x571 67 78 1 109 51 1 66 80 1 100 51 1 1.0 3.000 365 2580 0.12 1 7/16 x 2 3/4 2.68 3.22 4.56 2.03 2.64 3.45 4.22 2.03 2.4 DN65 76.1 2517 11476 3.048 M11 x69 68 82 116 52 67 88 107 52 1.1 3 3.500 365 3512 0.12 1 7/16 x 2 3/4 2.93 3.53 5.13 2.07 2.89 3.78 4.67 2.07 2.7 DN80 88.9 2517 15620 3.048 M11 x69 74 90 130 53 73 96 119 53 1.2 4 4.500 300 4771 0.17 1 7/16 x 2 3/4 3.47 4.01 6.03 2.08 3.43 4.22 5.56 2.08 3.5 DN100 114.3 2068 21223 4.318 M11 x69 88 102 153 53 87 107 141 53 1.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Reference the Listings/Approvals section of this publication for ratings on other pipe. 3 The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 109 Installation-Ready Rigid Couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. NOTES • When assembling Style 009V,Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For Style 009V,Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the "QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009V,Style 009N or Style 109 couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009V,Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009V,Style 009N or Style 109 couplings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctsulid victaulic.com 5.0 PERFORMANCE Style 009V Two-Bolt Installation-Ready Coupling Listings/Approvals Size cULus FM Actual Outside Nominal Diameter Sch. 104 Sch.404 Sch. 10 Sch.40 psi psi psi psi inches inches kPa kPa kPa kPa D N mm bar bar bar bar 1'/4 1.660 365 365 365 365 DN32 42.4 2516 2516 2515 2515 25 25 25 25 365 365 365 365 1 2516 2516 2515 2515 DN40 48.3 8.3 25 25 25 25 2 2.375 365 365 365 365 DN50 60.3 2516 2516 2515 2515 25 25 25 25 21/2 2.875 365 365 365 365 73.0 2516 2516 2515 2515 25 25 25 25 3.000 3658 — 365 365 DN65 76.1 2516" — 2516 2516 25" — 365 365 3 3.500 365 365 365 365 DN80 88.9 2516 2516 2515 2515 25 25 25 25 4 4.500 365 365 365 365 DN100 114.3 2516 2516 2515 2515 25 25 25 25 5.500 3009 — 365 365 DN125 139.7 20689 — 2516 2516 209 — 25 25 6.500 30010 — 300 365 165.1 206810 — 2068 2516 2010 — 20 25 6 6.625 300 365 300 365 DN150 168.3 2068 2516 2065 2515 20 25 20 25 8.515 3007 — 300 365 216.3 20687 — 2068 2516 207 — 20 25 3006 365 3005 365 D 8 85 2 9.1 20686 2516 20655 2515 206 25 205 25 10 10.750 3006 365 3006 365 DN250 273.0 20686 2516 20655 2515 206 JL 25 205 25 12 12.3.9 3006 365 3005 365 DN 2 323.9 20686 2516 20655 2515 206 25 205 25 4 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009V for details concerning when supplemental lubrication is required. 5 FM approved for 0.188"pipe wall. 6 cULus listed for 0.188"pipe wall. 7 cULus listed for JIS G3452 5.8mm pipe wall. 8 cULus Listed for EN10217 2.6mm pipe wall. 9 cULus Listed for EN10216 4.Omm pipe wall. 10 cULus Listed for EN10216 4.5mm pipe wall. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctsulid victaulic.com 5.1 PERFORMANCE Specialty Pipe Style 009V Two-Bolt Installation-Ready Coupling Listings/Approvals Pipe Type Size Pressure Rating Pressure Rating UIL FM psi psi inches kPa kPa DN bar bar 1 1/4—4 300 300 DN32—DIN 100 2068 2065 20 20 1 1/4-2 300 EL DN32—DN50 — 2065 20 1 1/4-6 300 300 MF DN32—DN150 20668 22665 20 11/2—4 300 300 FF DN40—DN100 2068 2065 20 20 11/4-4 300 DN32—DN 100 — 2065 HF 20 2-4 300 — DN50—DN 100 2068 — 20 — 1 1/4-2 300 300 ET40 DN32—DN50 2068 2065 20 20 1 1/4-2 300 300 EZT DN32—DN50 2068 2065 20 20 1 1/4-2 300 300 MT DN32—DN50 2068 2065 20 20 11/4—2 300 300 MLT DN32—DN50 2068 2065 20 20 1 1/4—4 175 300 Easy-Flow DN32—DN100 1206 2065 12 20 11/4-4 175 WG5,WG5E,WF5,WL7 DN32—DN100 1206 — 12 1 1/4—4 175 300 WG7,WG7E DN32—DN100 1206 2065 12 20 1 1/4-2 300 WLS DN32—DN50 — 2065 20 1 1/4-2 300 GL DN32—DN50 200665 20 NOTES • Easy Flow=Steel pipe manufactured by Borusan Mannesmann Boru • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,WFlow 5 steel pipe • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. manufactured by Wuppermann Stahl GmbH. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,Wgalweld 7E,WLight 7 steel pipe • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • GL=GL steel pipe manufactured by Wheatland Tube Co. • HF=Hydroflow sch 7 steel pipe manufactured by Nucor Tubular Products Inc. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 7 ✓ctsulid victaulic.com 5.2 PERFORMANCE Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus1116 FM16 VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch.40 Sch. 10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa DIN mm bar bar bar bar bar bar 11/4 1.660 365JE 365 363 363 363 363 DN32 42.4 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 11/2 1.900 365 365 363 363 363 363 DN40 48.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 2 2.375 365 365 363 363 363 363 DN50 60.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 21/2 2.875 365 365 363 363 363 73.0 2516 2516 2503 2503 — 2503 25 25 25 25 25 3.000 36512 36313 363 363 DN65 76.1 251612 — 250313 — 2503 2503 2512 2513 25 25 3 3.500 365 365 363 363 363 363 DN80 88.9 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 4 4.500 365 365 363 363 363 363 DN100 114.3 2516 2516 2503 2503 2503 2503 25 25 25 25 25 25 4.250 363 363 108.0 — — 2503 2503 — — 25 25 5 5.563 365 365 363 363 232 363 141.3 2516 2516 2503 2503 1600 2503 25 25 25 25 16 25 36313 0 5.25.250 — — 250313 — — — 2513 29014 36313 232 363 5.500 DN125 5.500 199914 — 250313 — 1600 2503 2014 2513 16 25 6 6.625 300 365 300 363 232 363 DN150 168.3 2068 2516 2068 2503 1600 2503 20 25 20 25 16 25 6.250 36313 159 — — 250313 — — — 2513 11 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 12 cULus listed for DIN 2458(EN 10220)2.6 mm pipe wall. 13 FM approved for BS 1387(EN 10255)Medium 3.6 mm pipe wall. 14 cULus listed for EN 10220 4.0 mm pipe wall. 15 cULus listed for EN 10255 4.5 mm pipe wall. 16 For optional stainless steel fasteners,reference the UL Product IQ and FM Approval Guide websites for working pressure ratings. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctsulid victaulic.com 5.2 PERFORMANCE (CONTINUED) Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approval agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULUS1720 FM20 VdS LPCB Actual Outside Nominal Diameter Sch. 10 Sch.40 Sch. 10 Sch.40 psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON mm bar bar bar bar bar bar 6.500 29019 36318 363 165.1 199919 — 250318 — — 2503 2019 2518 25 8.625 30022 365 30021 363 232 363 8 206822 2516 206821 2503 1600 2503 DN200 219.1 2022 25 2021 25 16 25 23 18 8.515 199923 — 250318 — — — 216.3 2023 2518 .750 30022 300 30021 300 290 10 10 DN250 273.0 0 206822 2068 206821 2068 — 2000 2022 20 2021 20 20 30022 300 25021 300 290 12 12.750 206822 2068 172021 2068 — 2000 DN300 323.9 2022 1 20 1721 1 20 1 20 17 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-009N for details concerning when supplemental lubrication is required. 18 FM approved for BS 1387(EN 10255)Medium 3.6 mm pipe wall. 19 cULus listed for EN 10255 4.5 mm pipe wall. 20 For optional stainless steel fasteners,reference the UL Product IQ and FM Approval Guide websites for working pressure ratings. 21 FM Approved for 0.188"pipe wall. 22 cULus Listed for 0.188"pipe wall. 23 cULus Listed for JIS G3452 pipe. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 9 ✓ctsulid victaulic.com 5.3 PERFORMANCE Specialty Pipe Style 009N Two-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating UL FM psi psi inches kPa kPa Pipe Type DN bar bar 1'/a—4 300 EF DN32—DN 100 2068 — 20 300 300 EL 1'/a-2 2068 2068 DN32—DN50 20 20 3-4 300 EZF DN80—DN 100 2068 — 20 300 300 1'/a—4 2068 2068 DN32—DN100 MF 20 20 6 175 175 DN150 1206 1207 12 12 1'/2-4 300 FF DN40—DN 100 20668 20 300 1 Ya—2 _ ET40 DN32—DN50 2068 20 1'/a—2 300 300 EZT DN32—DN50 2068 2068 20 20 300 300 MT 1 Ya—2 2068 2068 DN32—DN50 20 20 1'/a 2 300 MLT DN32—DN50 — 2068 20 1'/a—4 300 Easy Flow DN32—DN100 — 2068 20 1'/a—4 300 300 WG5,WG5E,WF5,WG7,WG7E,WL7 DN32—DIN 100 2068 2068 24 20 300 DN65 TF(Tex-Flow) 2'/-ID 4 DN 100 — 2068 20 1'/a—2 300 WLS DN32—DN50 — 2068 20 1'/a—2 300 GL DN32—DN50 2068 20 NOTES • Easy Flow=Steel pipe manufactured by Borusan Mannesmann Boru • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,WFlow 5 steel pipe • EZF=EZ-Flow,steel pipe manufactured by Northwest Pipe Co. manufactured by Wuppermann Stahl GmbH. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,Wgalweld 7E,WLight 7 steel pipe • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • GL=GL steel pipe manufactured by Wheatland Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctsulid victaulic.com 5.4 PERFORMANCE Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Size cULus24 FM VdS LPCB Actual Outside Sch. 10 Sch.40 Sch. 10 Sch.40 Nominal Diameter psi psi psi psi psi psi inches inches kPa kPa kPa kPa kPa kPa ON m m bar bar bar bar bar bar 11/4 1.660 365 365 365 365 232 363 DN32 42.4 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 11/2 1.900 365 365 365 365 232 363 DN40 48.3 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 2 2.375 365 365 365 365 232 363 DN50 60.3 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 21/2 2.875 365 365 365 365 73.0 2516 2516 2517 2517 — — 25 25 25 25 3.000 365 365 232 363 DN65 — — 2517 2517 1600 2503 25 25 16 25 3 3.500 365 365 365 365 232 363 DN80 88.9 2516 2516 2517 2517 1600 2503 25 25 25 25 16 25 4 4.500 300 300 300 300 290 DN100 114.3 2068 2068 2068 2068 — 2000 20 20 20 20 24 Listed/Approved for continuous use in wet and dry systems.Listed/Approved for dry systems-40'F/C and above. Reference Victaulic Installation Manual 1-109 for details concerning when supplemental lubrication is required. NOTE • With optional stainless steel fasteners,cULus Listed to 300 psi/2068 kPa/20.6 bar and FM Approved to the FM ratings shown in the above table.The stainless steel fasteners have a marking designation of"316"on the head of the bolt. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 11 ✓ctsulid victaulic.com 5.5 PERFORMANCE Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DN bar bar 1 1/4—21/2 300 DN32—73.0 mm — 2068 20 1 1/2—21/2 300 EF DN40—73.0 mm 20668 20 300 300 3-4 DN80—DN100 2068 2068 20 20 11/4-2 300 DN32—DN50 2068 Easy Flow 20 3-4 300 DN80—DN100 — 2068 20 11/4-2 300 EL DN32—DN50 — 2068 20 11/a 2 300 300 ET40 DN32—DN50 2068 2068 20 20 11/4-2 300 DN32—DN50 — 2068 EZT 20 11/2-2 300 DN40—DN50 2068 — 20 1 1/2—4 300 300 FF DN40—DN 100 20268 20068 20 11/4-2 300 GL DN32—DN50 — 2068 1 1/4—4 300 300 MF DN32—DN100 20268 2068 20 11/a 2 300 300 MT DN32—DN50 2068 2068 20 20 1 1/4-2 300 300 MLT DN32—DN50 2068 2068 20 20 NOTES • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • Easy Flow=Easy Flow steel pipe manufactured by Borusan Mannesmann • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. Boru. • MLT=MLT steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. . TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. . WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,and WFlow 5 steel pipe • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,WL7=WGalweld 7,WGalweld 7E,and WLight 7 steel pipe • GL=GL steel pipe manufactured by Wheatland Tube Co. manufactured by Wuppermann Stahl GmbH. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 0 2025 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctsulid victaulic.com 5.5 PERFORMANCE (CONTINUED) Specialty Pipe Style 109 One-Bolt Installation-Ready Coupling Listings/Approvals Size Pressure Rating cULus FM inches psi psi kPa kPa Pipe Type DIN bar bar 21/2 —4 300 TF 73.00 mm—DN 100 2068 20 1 1/4-4 300 WG5,WG5E,WF5,WL7 DN32—DIN 100 2068 — 20 1 1/4-4 300 300 WG7,WG7E DN32—DN100 2068 2068 20 20 11/4-2 300 WLS DN32—DN50 — 2068 20 NOTES • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • Easy Flow=Easy Flow steel pipe manufactured by Borusan Mannesmann • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. Boru. • MLT=MLT steel pipe manufactured by Wheatland Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. . TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. . WG5,WG5E,WF5=WGalweld 5,WGalweld 5E,and WFlow 5 steel pipe • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. manufactured by Wuppermann Stahl GmbH • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • WG7,WG7E,W1_7=WGalweld 7,WGalweld 7E,and WLight 7 steel pipe • GL=GL steel pipe manufactured by Wheatland Tube Co. manufactured by Wuppermann Stahl GmbH. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctsulid victaulic.com 6.0 NOTIFICATIONS AWARNING _ Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. . Failure to follow these instructions could result in death or serious personal injury 0 and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA)standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. NOTICE • If using coated pipe, always reference the installation instructions for pipe preparation requirements. 7.0 REFERENCE MATERIALS 05.01:Seal Selection Guide 25.01:Original Groove System(OGS)Groove Specifications I-009N:Installation Instructions Firel-ock EZTm Rigid Coupling Style 009N 1-009V:Installation Instructions Firel-ockTm Installation-ReadyTm Rigid Coupling Style 009V 1-100:Victaulic Field Installation Handbook 1-109:Installation Instructions Firel-ockTM One-Bolt Rigid Coupling Style 109 I-ENDCAP:Victaulic End Caps Installation Instructions I-IMPACT:Impact Tool Usage Guidelines User Responsibility for Product Selection and Suitability Intellectual Property Rights Each user bears final responsibility for determining the suitability of Victaulic products No statement concerning the use of any material,product,service,or design is for their end-use application,in accordance with industry standards,project specifica- intended,or should be construed,to grant any license under any patent or other tions,and Victaulic's published performance,maintenance,and safety data,as well intellectual property right of Victaulic or any of its affiliates,or as a recommendation as all warnings and installation instructions.Nothing in this or any other document, for the use of such material,product,service,or design in the infringement of any nor any verbal recommendation,advice,or opinion from any Victaulic employee,shall patent or other intellectual property right.The terms"Patented"or"Patent Pending" be deemed to alter,vary,supersede,or waive any provision of Victaulic Company's refer to design or utility patents or patent applications for articles and/or methods of standard conditions of sale,warranty,installation instructions,or this disclaimer. use in the United States and/or other countries.Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company,and/or its affiliated Installation entities,in the U.S.and/or other countries. Always refer to and follow the Victaulic Installation Handbook or installation instructions for the product you are installing.Handbooks are included with each Note shipment of Victaulic products,providing complete installation and assembly data, All products bearing a Victaulic trademark are manufactured by Victaulic or to and are available in PDF format on our website at victaulic.com. Victaulic specifications.All products are to be installed only in accordance with the applicable Victaulic installation instructions.Victaulic reserves the right to change Warranty product specifications,designs and standard equipment without notice and without Refer to the Warranty section of the current Price List or contact Victaulic for details. incurring obligations. 10.64 7072 Rev V Updated 03/2025 ©2025 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaulic° Victaulic° FireLockT" Fittings ✓ctaulic° 10.03 0 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4—8"/DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTm Fittings conform to the ratings of Victaulic Fire Lock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS D& <FM > LPCB vdS C E LISTED EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS — MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ❑ Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. 1 �ctaulicr victaulic.com 4.0 DIMENSIONS �CtoE� tC n o E CtoE p p - n �� -0 C T toE J � ele tE � o o No.001 No.003 No.002 No.006 No.001 No.003 No.002 No.006 90'Elbow 45'Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg I mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 11/2 1.900 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic° victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No.002 Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 1/4 1.660 - - - DN32 42.4 - - - - 1 1/2 1.900 - - - - DN40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN 125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN 150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 - 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctauIii victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling Fire Lock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Fire Lock EZTM Style 009N/009H couplings, use FireLockTm No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64:Victaulic@ FireLockTm Rigid Coupling Style 009N 10.02:Victaulic®FireLockTm Rigid Coupling Style 005H with Vic-PIUSTm Gasket System 29.01:Victaulic@ Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending'refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctauliill Flexible Coupling �� PM �c vds L PCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIP0 STYLE 75 Style 75 is available where moderate pressures are expected or weight _ considerations are a factor. Up to 50%lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500psi/3450kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade"EHP"or"T"gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade"EHP"or"T"gaskets.Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference document 17.09 for pressure ratings and end loads.When used on light wall stainless steel pipe,the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel,refer to document 17.01. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating:Orange enamel. • Optional: Hot dipped galvanized and others. Gasket:(specify choice') • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+860F/+30°C and hot+180°F/+820C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20OF to+180°F/-290C to+820C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. NOTE:Additional gasket styles are available.Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. �otaiullc° REV_N 06.05_1 CARBON STEEL PIPE-GROOVED COUPLINGS 06.05 Flexible Coupling STYLE 75 DIMENSIONS Max.Work All w.Pipe Bolt/Nut@ Approx. Size Pressure Max.End Load Eno Sep.t Deflect.Fr.CLt No-Size Dimensions-Inches/mm Wgt.Each Actual Nominal Outside Size Diameter Pe, Pipe Inches Inches psi Lbs. Cplg In./Ft. i10 a N n1m Deg. mm/M Inches X Y Z kg"q, mm n1m kPa 7 7 1 1.315 500 680 0-0.06 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 2"-43' 48 2-3/s x 2 61 108 45 0.6 1/4 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 -10 38 2-3/a x 2 68 117 45 0.6 1 Y2 1.900 500 1420 0-0.06 0.40 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 1 -56 33 2-3/e x 2 74 12 445 0.6 2 2.375 500 2215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 -31 26 2-'/e x 2 87 133 48 0.8 2 Y2 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1°-15' 22 2-3/e x 2 98 144 48 0.9 3.000 500 3535 0-0.06 0.26 4.00 5.90 1.88 1.9 76.1 mm 76.1 3450 15730 0-1.6 1 -12 22 2-3/a x 2 102 150 48 0.9 3 3.500 500 4800 0-0.06 1'-2' 0.22 2-,/5 x 2 3/4 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 3 Y2 4.000 500 6300 0-0.06 0"-54' 0.19 2-1/2 x 2 3/45.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0.13 1'-36' 0.34 2-Y2 x 2 3/4 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 4.250 450 6380 0-0.13 0.35 5.55 7.79 2.13 3.7 108.0 m m 108.0 3100 28395 0-3.2 1 -41' 29 2-12 x 70.0 141 198 54 1.7 4�/2 5.000 450 8820 0-0.13 1°-26' 0.25 2-5/8 x 3'/4 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 21 156 240 54 2.5 5 5.563 450 10935 0-0.13 1°-18' 0.27 2-5/8 x 3 1/46.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 1 256 54 2.6 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 133.0 m m 133.0 3100 43325 0-3.2 1 -21 24 2-16 x 82.5 166 238 54 2.7 139.7 m m 5.500 450 10665 0-0.13 1°-18' 0.28 2-s/e x 3'/4 6.80 9.59 2.13 6.3 139.7 3100 47460 0-3.2 24 173 244 54 2.9 6.000 450 12735 0-0.13 0.21 7.38 10.48 1.88 6.2 152.4 m m 152.4 3100 56670 0-3.2 1 -12 5/e x 3 V4 18 2- 187 266 48 2.8 6 6.625 450 15525 0-0.13 1. 5, 0.23 2-5/8 x 3'/4 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 6.250 450 13800 0-0.13 0.24 7.63 10.49 2.13 6.8 159.0 mm 159.0 3100 61405 0-3.2 1 -9' 20 2-16 x 82.5 194 266 54 3.1 8 8.625 450 26280 0-0.13 0°-50' 0.18 2-3/4 x 4 Ya 10.34 13.97 2.32 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 * Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2720-90 mm;25%for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. �Y � I�Z�I X www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED.. d%taUliC® 06.05_2 REV_N :..r:�' 1 . 1 Flexible Coupling STYLE 75 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. For complete contact information,visit www.victaulic.com 06.05 1470 REV N UPDATED O1/2013 �Citaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.05 CO® Worldwide www.tyco-fire.com Contacts Model BFV.300/0FV.300C Butterfly Valve Grooved End General Technical Description Data w The TYCO Models BFV-300 and BFV- Approvals 300C Grooved End Butterfly Valves UL and ULC Listed are indicating type valves designed for FM Approved use in fire protection systems where CE Certified a visual indication of open or closed VdS Approved valve condition is required. They are Russian Fire Certificate used, for example, as system, sec- CNPP R1 Listed-APSAD tional and pump water control valves. Listed by California State Fire Marshall They have grooved inlet and outlet con- Refer to Tables A,B and C for applicability. nections that are suitable for use with All laboratory listings and approvals are for grooved end pipe couplings listed or indoor and outdoor use. approved for fire protection systems. For applications requiring supervi- Sizes MODEL BFV-300 sion of the open or closed state of the 2-12 Inch(DN50-DN300) WITH OPEN SUPERVISORY valve,the Gear Operators for the Model UL/ULC/FM Maximum Working SWITCHES BFV-300/BFV-300C Butterfly Valves Pressure feature two sets of factory installed 2-8 Inch(DN50-DN200).... 300 psi(20,7 bar) internal switches each having SPDT 10-12 Inch(DN250-DN300)..175 psi(12,1 bar) , contacts (Ref. Figure 3). The super- VdS Maximum Working Pressure visory switches transfer their electri- 2-8 Inch(DN50-DN200).... 300 psi(20,7 bar) cal contacts when there is movement 10 Inch(DN250) ........... 232 psi(16,0 bar) from the open or closed disc position 12 Inch(DN300) ............175 psi(12,1 bar) during the first two revolutions of the Maximum Working Temperature handwheel. 212°F(100`C)in accordance with UL 1091 Materials of Construction / Body.........................Ductile Iron The Model BFV-300/BFV-300C Body Coating ........... RILSAN PA11 Black Grooved End Butterfly Valves described Disc..........................Ductile Iron herein must be installed and maintained Disc Seal.Lower Stem Encapsulated Upper&Lower Stem.......... Stainless Steel in compliance with this document, as Handwheel ....................Ductile Iron well as with the applicable standards (BFV-300 red painted;BFV-300C black painted) of the National Fire Protection Asso- Actuator,2-6 Inch(DN50-DN150): ciation, in addition to the standards Of • IP 65, bronze traveling nut gearbox, ductile MODEL BFV-300C an other having jurisdiction. iron housing WITH CLOSED SUPERVISORY y gl Actuator,8-12 Inch(DN200-DN300): SWITCHES Failure to do so may impair the perfor- • IP 65,brass segmented gearbox,ductile iron mance of these devices. housing The owner is responsible for main- Silicone Free Model Availability ST, taining their fire protection system Silicone free models are available.Contact and devices in proper operating con- Tyco sales for information. dition. Contact the installing contrac- Tapping Bosses "9� g toe or product manufacturer with any Two factory-plugged NPT threaded tapping ERE questions. bosses in the valve body are located on the C E up- and downstream sides of the disc for connection to valve trim. Tapping boss CP sizes: <@> 2-3 inch(DN50-DN80).............3/8 NPT 4-12 inch(DN100-DN300)..........1/2 NPT APPROVED Control Valve Seat Leakage Class IEC 60534-4 CLASS VI(Type C)Control Valve Seat Leakage according to ANSI/FCI 70-2-2006(ASME B16.104) Page 1 of 8 JANUARY 2018 TFP1511 TFP1511 Page 2 of 8 Pipe Nominal Dimensions Nominal P Valve Size ip Inches Weight (mm) Lbs. Inches Inches (kg) (DN) (mm) A B C D E F G H J 2 2.37 3.8 10.63 2.85 4.90 4.92 4.28 1.99 10.8 DN50 60,3 96,4 270 72,5 124,5 125 108,E 50,5 0 0 4,9 2-1/2 2.88 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 DN65 73,0 96,4 297,8 85 139,8 125 108,E (50,5) 0 0 5,9 3 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 DN65 76,1 96,4 297,8 85 139,8 125 108,E (50,5) 0 0 5,9 3 3.5 3.8 12.22 3.58 5.76 4.92 4.28 1.99 13.9 DN80 88,9 96,4 310,3 91 146,3 125 108,E 50,5 0 0 6,3 4 4.5 4.54 13.92 4.29 6.75 4.92 4.28 1.99 17.64 DN100 114,3 115,4 353,5 109 171,5 125 108,E 50,5 0 0 8,0 5.5 5.83 16 5.16 7.93 5.91 5.79 2.32 26.4 DN125 139,7 148 406,E 131 201,5 150 147 (58,9) 0 0 11,9 5 5.56 5.83 16 5.16 7.93 5.91 5.79 2.32 26.4 DN125 141,3 148 406,E 131 201,5 150 147 58,9 0 0 11,9 6.5 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN150 165,1 148 433,E 145 214,5 150 147 (58,9) 0 0 13,8 6 6.63 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN150 168,3 148 433,E 145 214,5 150 147 (58,9) 0 0 13,8 8 8.63 5.24 19.67 6.69 9.29 8.86 8.19 2.76 5.66 1.24 47.18 DN200 219,1 133 499,5 170 236 225 208 70 143,7 31,4 21,4 10 10.75 6.26 22.46 7.68 11.1 11.14 8.19 2.91 7.21 1.65 73.41 DN250 273 159 570,5 195 282 283 208 74 183,1 41,8 33,3 12 12.75 6.5 25.39 9.5 12.2 11.14 8.19 2.91 9.96 2.7 89.29 DN300 323,9 165 645 241,5 310 283 208 74 252,9 68,5 40,5 SEGMENTED HANDWHEEL GEAR OPERATOR 8 TO 12 INCH E INDICATOR (DN200 TO DN300) FLAG VALVE SIZES T CD - (VALVE CLOSED)---h qq= F TAPPING O O G BOSSES B IuIi�V HANDWHEEL INDICATOR HANDWHEEL BODY FLAG (VALVE TAPPING 0 0 OPEN) 0 BOSSES----- n A o (pn' 1 o TAPPING 1 BOSSES � \ DISC J H TRAVELLING NUT TRAVELLING NUT ELECTRICAL CONNECTOR GEAR OPERATOR GEAR OPERATOR 2 TO 4 INCH 5 TO 6 INCH (DN50 TO DN100) (DN125 TO DN150) VALVE SIZES VALVE SIZES FIGURE 1 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS FP1511 Page 3of8 No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. ASTM ASTM ASTM 01 Body A-536 1 15 Spring Pin A-228 1 30 Bolt(Round) A-167 3 02 Upper Stem AISI 410 1 16 Indicator AST 1 31 Plate Washer AS16M 4 03 Lower Stem AISI 410 1 17 O-Ring NBR 1 32 Switch Assembly — 1 04 Disc EPDM 1 18 Cover Gasket Paper 1 33 T/R Bolt ASTM 2 A-307 05 O-Ring(P12) EPDM 4 19 Spring Pin ASTM 1 34 Tapping Screw S10C 1 05x1Tx25 A-228 ST3.5 x 7.5 06 Oiless B/R — 4 20 O-Ring(P10) EPDM 1 35 Tooth Washer 4# S10C 1 MB1410 07 2-E2-4 Inpch EPDM 1 21 Worm Shaft AISI 410 1 36 Lever ASTM 1 08 Gear Box ASTM 1 22 Bushing(1) FD-0205-45 1 37 Connector — 1 A-536 Traveling Nut Bronze 1 23 Collar FD-0205-45 1 38 Sticker — 1 09 2-6 Inch Segment Gear C3604BD 1 24 Spring Washer ASTM 4 39 Sticker — 1 8-12 Inch A-167 10 Bushing(2) FD-0205-45 1 25 Hex Bolt ASTM 2 40 Spring Pin ASTM 1 M8 x 20L A-167 03x0.6Tx25 A-228 11 Cover ASTM 1 26 Hex Bolt ASTM 2 Headless Plug A-619 M8 x 25L A-167 3/8 NPT 12 Bushing Fe 1 27 Gasket Paper 1 41 2-3 Inch ASTM 2 Headless Wrench ASTM Spring Pin ASTM A-307 13 Bolt M5 x 7L A-307 1 28 04x0.8tx25 A-228 1 Headless Plug ASTM 1/2 NPT A 14 Stem Housing Fe 1 29 Handwheel ASTM 1 4-12 Inch 35 34 37 33 30 37 33 35 36 \ 30 32 / 34 32 36 O o 38,39 a 38,39 28 31 28 ----------- 31 30 30 19, 19, 29 20 40 17 14 12 18 29 20 40 17 14 12 18 16 16 —------------- 11 11 15 / 15 -_—- 21 10 21 10 13 13 22 09 22 09 27 27 -- 23 08 23 08 25 25 24 05 24 05 26 26 25 02 25 02 01 41 01 41 04 — 03 04 03 06 -07 06 07 BFV-300 Normally Open Valve BFV-300C Normally Closed Valve Supervisory Switch Arrangement Supervisory Switch Arrangement FIGURE 2 MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE ASSEMBLY TFP1511 Page 4of8 FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 200 400 600 1000 2000 4000 6000 10000 20000 9.0 0,60 8.0 7.0 0,50 6.0 0,40 5.0 �yo� 0,30 4.0 O � m _ Q a = 2.0 = 0 ti 0,20 z oz o w 0m w =U =w cr 2.0 ^ ^pp o w00 w � ti Z� `O= ti o (L M Z =� 010 w � w a =V �yo 0,09cr z o o V� Q2 0,08 aJ a OD 1.0 007 zv z 0- 0.9 2� 0 0,06 0 z 0.8 CO 0 0.7 Q=� �cL o 0,05 z 0.6 V� S =�0 0,04 0.5 =U cb `O ,moo V� 0,03 0.4 �N 0.3 50 60 80 100 200 400 600 800 1000 2000 4000 6000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW YELLOW F------- YELLOW i S-1 FIRE ALARM COMMON(WHITE) COMMON(WHITE) END OF LINE CONTROL PANEL RESISTOR SUPERVISORY RED RED OR CIRCUIT NEXT DEVICE MODEL BFV-300/BFV-300C I GREEN GEAR OPERATOR OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC I I BLUE 5A 24VDC SWITCH S-1,2 LEADS PER CONTACT SWITCH S-2, 1 LEAD PER CONTACT i S-2 COMMON(BLACK) I I ORANGE VOLTAGE L_____J AUX. DEVICE SOURCE ____ ____ (BELL OR HORN) FIGURE 3 MODEL BFV-300 BUTTERFLY VALVE OPEN POSITION—SUPERVISORY SWITCH OPEN POSITION MODEL BFV-300C BUTTERFLY VALVE CLOSED POSITION—SUPERVISORY SWITCH CLOSED POSITION INTERNAL SWITCH WIRING DIAGRAM FP1511 Page 5of8 Nominal Pipe Part Number A enc Listing/Approval Valve Size O.D. Max. BFV-300 BFV-300C CA Fire Russian Inches Inches (bar) Supv.Switch Supv.Switch CIE UL ULC FM VdS Marshall CNPP PAVUS Fire (DN) (mm) OPEN CLOSED Cert. 2 2.38 300 5930OG02OWS 5930OG02OWSC ✓ ✓ ✓ ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25WS 59300GO25WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 73,0 20,7 3 300 59300GO26WS 59300GO26WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 76,1 20,7 3 3,5 300 5930OG03OWS 5930OG03OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 5930OG04OWS 5930OG04OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300GO56WS 59300GO56WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 5930OG05OWS 5930OG05OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66WS 59300GO66WSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 5930OG06OWS 5930OG06OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 5930OG08OWS 5930OG08OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG10OWS 5930OG10OWSC ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG12OWS 5930OG12OWSC ✓ ✓ ✓ ✓ ✓ ✓ DN300 323,9 12,1 TABLE A MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Pipe Part Number Agency Listing roval Valve Size O.D. Max. BFV-300 BFV-300C Inches Inches (bar) Supv.Switch Supv.Switch CIE VdS CNPP (DN) (mm) OPEN CLOSED 2 2.38 300 59300GO20AWS 59300GO20AWSC ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25AWS 59300GO25AWSC ✓ ✓ ✓ DN65 73,0 20,7 3 300 DN65 76,1 20,759300G026AWS 59300GO26AWSC ✓ ✓ ✓ 3 3,5 300 59300GO30AWS 59300GO30AWSC ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 59300GO40AWS 59300GO40AWSC ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300GO56AWS 59300GO56AWSC ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 59300GO50AWS 59300GO50AWSC ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66AWS 59300GO66AWSC ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 59300GO60AWS 59300GO60AWSC ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 59300GO80AWS 59300GO80AWSC ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG100AWS 5930OG100AWSC ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG120AWS 5930OG120AWSC ✓ ✓ ✓ DN300 323,9 12,1 TABLE B MODEL BFV-3001BFV-300C GROOVED END BUTTERFLY VALVE WITH CNPP-APSAD LARGE 100 X 100 MM FLAG AND INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS TFP1511 Page 6 of 8 Nominal Pipe enc Listin /A roval Max.. Valve Size O.D. Part Russian Inches Inches (bar) Number CE UL ULC FM VdS CA Fire Marshall CNPP PAVUS Fire (DN) (mm) Cert. 2 2.38 300 5930OG02ONS ✓ ✓ ✓ ✓ ✓ ✓ DN50 60,3 20,7 2-1/2 2.88 300 59300GO25NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 73,0 20,7 3 300 59300GO26NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN65 76,1 20,7 3 3,5 300 5930OG03ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN80 88,9 20,7 4 4.5 300 5930OG04ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN100 114,3 20,7 5.5 300 59300G056NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 139,7 20,7 5 5.56 300 5930OG05ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN125 141,3 20,7 6.5 300 59300GO66NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 165,1 20,7 6 6.63 300 5930OG06ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN150 168,3 20,7 8 8.63 300 5930OG08ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN200 219,1 20,7 10 10.75 175 5930OG10ONS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN250 273 12,1 12 12.75 175 5930OG12ONS ✓ ✓ ✓ ✓ ✓ ✓ DN300 323,9 12,1 TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Part Number Nominal Bernstein Operator Valve Size Gear Mounting Bernstein Bernstein GC-SU1Z Inches Type Bracket with i88-IP i88-IP65 65 LED Switch Ex IP-66/67 ATEX (DN) Mounting Bolts Regular Switch 24V (Ex 112G Ex dlIC T6 Gb) Switch 2-4 59300SPBRACKET10 (DN50-DN100) Travelling 5-6 Nut 59300SPBRACKET20 DN125-DN200 59300SPSW 59300SPSWLED 59300SPSWATEX 8 59300SPBRACKET25 DN200 Segmented 10-12 Gear 59300SPBRACKET30 DN250-DN300 Notes: 1. Install a single switch in either bracket mounting position to monitor Open or Closed valve condition r--- —� a I I ® Bernstein Switch Wiring Diagram TABLE D MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES ACCESSORY EXTERNAL SUPERVISORY SWITCHES AND MOUNTING BRACKETS PART NUMBER SELECTION FP1511 Page 7 of 8 Installation Nominal Valve Size Part Number Inches BFV-300,Red Painted BFV-300C,Black Painted The Model BFV-300/BFV-300C (DN) Grooved End Butterfly Valves may be 2-4 59300SPHWHEELIO 59300SPHWHEELIOB installed with flow in either direction DN50-DN100 and can be positioned either horizon- 5-8 59300SPHWHEEL20 59300SPHWHEEL20B tally or vertically. DN125-DN200 10-12 59300SPHWHEEL30 59300SPHWHEEL30B The grooved end pipe couplings DN250-DN300 used with the Model BFV-300/BFV- TABLE E 300C must be listed or approved for BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE fire protection service and installed in REPLACEMENT HANDWHEEL accordance with the manufacturers PART NUMBER SELECTION instructions. The Model BFV-300/BFV-300C But- Limited Accessories terfly Valve may be installed with any schedule of pressure class of pipe or External Supervisory Switch and tubing that is listed or approved for fire Warranty Mounting Bracket protection. For warranty terms and conditions,visit Note: Accessory external supervi- Conduit and electrical connections www.tyco-fire.com. sory switches and mounting brackets are to be made in accordance with are applicable only to valves without the authority having jurisdiction and/ Ordering factory-installed internal supervisory or the National Electrical Code. With switches. reference to Figure 3, the supervisory procedure Refer to Table D for switch models and switch is intended for connection to part numbers. the supervisory circuit of a fire alarm Contact your local distributor for avail- control panel in accordance with NFPA ability.When placing an order, indicate Specify: (specify size) Model BFV-300 72.The auxiliary switch is intended for the full product name and Part Number Grooved End Butterfly Valve Exter- the unsupervised connection to aux- (P/N). nal Switch Mounting Bracket, P/N iliary equipment in accordance with (specify), with (specify quantity) Bern- NFPA 70, National Electric Code. Butterfly Valves stein External Switch (specify model), NOTE: For outdoor applications with Model BFV-300 with Internal P/N (specify) internal supervisory switches, it is rec- Open Supervisory Switches Replacement Parts ommended that wiring connections Specify: (specify size) Model BFV-300 Note: Only items described in this be made at a temperature above 15°F Grooved End Butterfly Valve, Inter- section are offered as replacement (-9°C),in order to insure sufficient flex- nal Open Supervisory Switches, parts. ibility of the wire lead insulation. P/N (specify per Table A) Handwheel Model BFV-300C with Internal Replacement handwheel includes pin. Care and Closed Supervisory Switches Refer to Table E for part numbers. Maintenance Specify: (specify size) Model BFV- Model BFV-300 Red Painted 300C Grooved End Butterfly Valve, Before closing a fire protection system Internal Closed Supervisory Switches, Specify: Handwheel, (specify size) control valve for maintenance or P/N (specify per Table A) Model BFV-300 Grooved End Butter- inspection work on either the valve or Model BFV-300 with Internal fly Valve, P/N (specify) fire protection system which it con- Open Supervisory Switches, Model BFV-300C, Black Painted trols, permission to shut down the APSAD Approved Specify: Handwheel, (specify size) affected fire protection systems must Specify: (specify size) Model BFV-300 Model BFV-300C Grooved End But- be obtained from the proper authorities Grooved End Butterfly Valve, Internal terfly Valve, P/N (specify) and all personnel who may be affected Open Supervisory Switches, APSAD by this decision must be notified. Approved, P/N(specify per Table B) The owner is responsible for the Model BFV-300C with Internal inspection,testing,and maintenance of Closed Supervisory Switches, their fire protection system and devices APSAD Approved in accordance with the applicable stan- Specify: (specify size) Model dards of the National Fire Protection BFV-300C Grooved End Butter- Association(e.g., NFPA 25), in addition fly Valve, Internal Closed Supervi- to the standards of any authority having sory Switches, APSAD Approved, jurisdiction.Contact the installing con- P/N (specify per Table B) tractor or product manufacturer with any questions. Any impairment must Model BFV-300 without Internal be immediately corrected. Supervisory Switches It is recommended that automatic Specify: (specify size) Model BFV-300 sprinkler systems be inspected,tested, Grooved End Butterfly Valve, and maintained by a qualified inspec- tion service. TFP1511 Page 8of8 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson I nson ORO RILSAN Is a registered trademark of Ark,,,,Inc. Controls tqCOWorldwide Fire Protection Contacts www.tyco-fire.com Products Model CV-1F Grooved End Swing Check Valves The owner is responsible for main- General taining their fire protection system Descr►nt�On and devices in proper operating con- M dition. Contact the installing contrac- The TYCO Model CV-1 F Grooved End for or product manufacturer with any Swing Check Valves are compact questions. and rugged swing-type units that allow water flow in one direction and Technical prevent flow in the opposite direction. _ A resilient elastomer seal facing on the Data spring-loaded clapper ensures a leak- k; tight seal and non-sticking operation. Approvals The Model CV-1 F Check Valves are Compliance with CE Pressure designed to minimize water hammer Equipment Directive(PED)and caused by flow reversal. Standards of Engineering Practice The Model CV-1 F Grooved End Swing • 2 to 12 Inch (DN50 to DN300): u` C FM Check Valves are furnished with UL and C-UL Listed, FM Approved, grooved ends and can be installed Bureau Veritas APPROVED using GRINNELL Grooved Couplings °F9 or GRINNELL Figure 71 Flange Adapt- VdS to Inch (DN65 to DN250): �+ ers. The Model CV-1F Check Valves dSApproved Vds have been designed with a removable Certificate No. G4060018 ,azs cover for ease of field maintenance. Sizes For fire protection pressure rating, These valves can be installed horizon- 2 to 12 Inch(DN50 to DN300) listing and approval information,contact tally(with cover in the upward position) your TYCO representative. or vertically with the flow in the upward Maximum Working Pressure direction(Ref. Figure 3). UL/FM -300 psi (20,7 bar) Installation VdS- 16 bar A check valve maintenance kit is avail- Valve Assembly Finish The Model CV-1 F Grooved End Swing able to allow backflushing through a Red, non-lead paint Check Valves are to be installed in fire department connection without accordance with this section: removing the Model CV-1F Grooved End Swing Check Valve from the riser. Step 1. The arrow cast on the body Refer to technical data sheet TFP1555. must point in the direction of the flow. Model CV-1F is a re-designation for Step 2. Valves installed vertically Central Figure 590F and GRINNELL must be positioned with the flow in the Figure 590F Grooved End Swing Check upward direction. Valves. Step 3. Valves installed horizontally must be positioned with the cover EEM facing up(Ref. Figure 3). The TYCO Model CV-1F Grooved End Step 4. Grooved end pipe couplings Swing Check Valves described herein used with the Model CV-1 F Grooved must be installed and maintained in End Swing Check Valves must be compliance with this document and installed in accordance with manufac- with the applicable standards of the turer's instructions. National Fire Protection Association (NFPA), in addition to the standards Note:Valves should be installed a rea- of any authorities having jurisdiction. sonable distance downstream from Failure to do so may impair the perfor- pumps, elbows, expanders, reducers, mance of these devices. or other similar devices to extend the piping component valve life.Standard piping practices call Never remove any pip nor correct or modify in in den for a minimum of five(5)times the pipe y y piping g diameter for general use. ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 6 FEBRUARY 2016 TFP1550 TFP1550 Page 2 of 6 Nominal Dimensions Nominal Pipe Size Inch Cover Approx. (mm) Bolt Weight Valve Size Pipe O.D. Torque Lbs.Lbs.-ft. (kg) Inch Inch A B C D E F J (Nm) (DN) (mm) 2 2.37 6.75 1.96 1.96 2.57 3.25 4.75 1.62 18 9.0 (50) (60,3) (171,5) (49,8) (49,8) (65,3) (82,3) (120,7) (41,5) (25) (4,5) 2-1/2 2.88 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (73,0) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 76,1 mm 3.00 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (76,1) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 3 3.50 8.37 5.72 2.81 3.31 3.87 5.87 1.63 39 11.0 (80) (88,9) (212,6) (145,3) (71,4) (84,1) (98,3) (149,1) (41,7) (54) (5,0) 4 4.50 9.63 6.68 3.80 3.63 4.53 7.13 1.84 50 25.0 (100) (114,3) (244,6) (169,7) (96,5) (92,2) (115,4) (181,1) (46,7) (69) (11,3) 1397 mm 5.50 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (139,7) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 5 5.56 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (141,3) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 165,1 mm 6.50 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 (150) (165,1) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 6 6.63 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 (150) (168,3) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 8 8.63 14.00 10.14 6.67 5.52 5.46 8.46 2.13 120 66.0 (200) (219,1) (355,6) (257,8) (169,4) (140,2) (138,7) (214,9) (54,1) (164) (29,9) 10 10.75 18.00 12.38 8.62 6.41 7.50 10.50 3.00 130 109.7 (250) (273,1) (457,2) (314,5) (218,9) (162,8) (190,5) (266,7) (76,2) (178) (49,4) 12 12.75 21.00 14.28 9.93 7.27 7.62 10.62 2.75 130 151.0 (300) (323,9) (533,4) (362,7) (252,2) (184,7) (193,5) (269,7) (69,9) (178) (68,0) B - A C O ♦ O.D. D 1 1 1/2" NPT 1/2" J NPT — E F - FIGURE 1 MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL DIMENSIONS Care and system from the proper authorities of the National Fire Protection Associa- and notify all personnel who may be tion (e.g., NFPA 25), in addition to the Maintenance affected by this decision. standards of any authority having juris- After placing a fire protection system diction. Contact the installing contrac- The TYCO Model CV-1 F Grooved End in service, notify the proper authorities for or product manufacturer with any Swing Check Valves must be main- and advise those responsible for moni- questions. Any impairments must be tained and serviced in accordance with toring proprietary and/or central station immediately corrected. this section. alarms. Automatic sprinkler systems are rec- Before closing a fire protection system The owner is responsible for the ommended to be inspected, tested, main control valve for maintenance inspection,testing,and maintenance of and maintained by a qualified Inspec- work on the fire protection system their fire protection system and devices tion Service in accordance with local that it controls, obtain permission to in compliance with this document, as requirements and/or national codes. shut down the affected fire protection well as with the applicable standards TFP155O Page 3 of 6 No. Part Material Oty. No. Part Material Oty. No. Part Material Oty. 1 Body Ductile Iron 1 6 Clapper Facing EPDM Grade"E 1 14 Locknut Steel Stainless 1 " 2 Cover Ductile Iron 1 7 Spring Stainless 1 15 Plug Cast Iron 2 Steel 1/2" NPT 3 Cover Gasket Nitrite 1 8 Hinge Shaft Stainless 1 16 Adhesive Thread AR Rubber Steel Sealer 4 Hex Cap Screw Steel, AR 9 Retaining Ring Stainless AR 17 Nameplate Aluminum 1 Zinc Plated Steel Clapper,2"-8" Stainless 11 Retention Bolt Stainless 1 18 Rivet Steel 2 5 (DN50-200) Steel 1 Steel Clapper,10"-12" Ductile Iron 13 Retaining Disc Stainless 1 19 Spacer Stainless 1 (DN250-300) Steel Steel 8 8 4,16 18 17 't�9 5 2 SEE 9 2 7 3 VIEW A 2" -8" 2 10"-12" 7 5 (DN50-DN200) (DN250-DN300) VIEW A 13 D SEE 5 13 �11,16 DETAIL B 11 1 14,16 I / 6 / 19 5 6 1 15 2"-8" 10"-12" (DN50-DN200) (DN250-DN300) DETAIL B FIGURE 2 MODEL CV-1F GROOVED END SWING CHECK VALVES ASSEMBLY FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 4.0 �o o� 0,30 = O= o Z IL Q 3.0 =VZ =U0,20 z o z `V 2V� =^rye �� a Cr LU Z CV 0 Ir CC 2.0 2V WA `O= o� Cr `� aLo w coo W C3 V O h oC co Ir = Z 2�' o� 0,10 U)o IL w co =V O = 0,09 EL w u z U) o C 0,08 a s g 0 1.0 = 2U 0,07 T Oz O 0.8 �o ".`y 0 06 z 0.7 0,05 o44t:1 1 in z woo All 0.6 0,04 0.5 12 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL PRESSURE LOSS VS. FLOW TFP1550 Page 4of6 Valve Size Pipe O.D. Inch Inch Part Number (DN) (mm) 2 2.37 59-590-0-020 (50) (60,3) 2-1/2 2.88 59-590-0-025 (65) (73,0) 76,1 mm 3.00 59-590-0-076 (65) (76,1) 3 3.50 59-590-0-030 (80) (88,9) 4 4.50 59-590-0-040 (100) (114,3) 139,7 mm 5.50 59-590-0-139 (125) (139,7) 5 5.56 59-590-0-050 (125) (141,3) 165,1 mm 6.50 59-590-0-165 (150) (165,1) 6 6.63 59-590-0-060 (150) (168,3) 8 8.63 59-590-0-080 (200) (219,1) 10 10.75 59-590-0-100 (250) (273,1) 12 12.75 59-590-0-120 (300) (323,9) TABLE A MODEL CV-1F GROOVED END SWING CHECK VALVES PART NUMBER SELECTION Valve Size Pipe O.D. Cover Gasket Part Number Clapper Facing Part Number Clapper Assembly Part Number Inch Inch (DN) (mm) Americas Only EMEA/APAC Americas Only EMEA/APAC Americas Only EMEA/APAC 2 2.37 595907020 97670501 59020EPDM 59020EPDM 97670201A 97670201 (50) (60,3) 2-1/2 2-88 595907030 97561801 59025EPDME 59025EPDM 97562801A 97562065 (65) (73,0) 76,1 mm 3.00 595907030 97561801 59025EPDME 59025EPDM — 97562801 (65) (76,1) 3 3.50 595907030 97561801 59030EPDME 59030EPDM 97562201A 97562201 (80) (88,9) (100) (44g) 595907040 97512001 59040EPDME 59040EPDM 97549001A 97549001 139,7 mm 5.50 595907040 97512001 59050EPDME 59050EPDM — 97565501 (125) (139,7) 5 5.56 595907040 97512001 59050EPDME 59050EPDM 97565501A 97562125 (125) (141,3) 165,1 mm 6.50 595907060 97521801 59060EPDME 59060EPDM — 97524101 (150) (165,1) 6 6.63 595907060 97521801 59060EPDME 59060EPDM 97524101A 97562150 (150) (168,3) (200) (2191) 595907080 97547901 59080EPDME 59080EPDM 97592201A 97592201 10 10.75 595907100 97600001 59100EPDM 59100EPDM 97598001A 97598001 (250) (273,1) 12 12.75 595907120 97600002 59120EPDM 59120EPDM 97647701A 97647701 (300) (323,9) TABLE B MODEL CV-1 F GROOVED END SWING CHECK VALVES REPLACEMENT VALVE PARTS PART NUMBER SELECTION TFP1550 Page 5of6 OUTLET Limited Ordering I� Warranty Procedure J 0 3: For warranty terms and conditions,visit Contact your local distributor for avail- COVER o www.tyco-fire.com. ability.When placing an order, indicate LL the full product name and Part Number (P/N). Model CV-1 IF Check Valve INLET Specify: Model CV-11F Grooved End VERTICAL ORIENTATION Swing Check Valve, size (specify), P/N (specify per Table A) COVER FLOW Replacement Valve Parts Refer to Figure 2 to identify Parts. Cover Gasket Specify: Model CV-1F Grooved End INLET O OUTLET Swing Check Valve,Cover Gasket,size (specify), P/N (specify per Table B) Clapper Facing HORIZONTAL ORIENTATION Specify: Model CV-1F Grooved End FIGURE 3 Swing Check Valve, Clapper Seal MODEL CV-1F GROOVED END Facing, EPDM Grade"E",size(specify), SWING CHECK VALVES P/N (specify per Table B) PROPER ORIENTATION Clapper Assembly Includes items 2, 3, 5-14, and 17-19. Specify: Model CV-11F Grooved End Swing Check Valve,Clapper Assembly, size(specify), P/N(specify per Table B) TFP155O Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tgg0 Fire Protection Products GL • E 4077 Airpark Dr. Standish, MI 48658 .989-846-4583•www.globesprinkler.com Technical Support•989 414 2600•techservice@globesprinkler.com MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY (With or Without Control Valve) 1%", 2", 2%", 76.1mm, 3", 4", 6", 165.1mm, 8" GENERAL DESCRIPTION The Globe Series "UMC' Universal Manifold Check is a first of its kind, UL Listed and FM Approved, complete floor control station or shotgun riser assembly. It is pressure rated for 300 psi (20,6 bar). It provides the most compact "footprint"while delivering all of the necessary components o for your floor control station as required by the NFPA Stan- dards. With its multiple available configurations, it allows the contractor to order the suitable configuration for the site specific needs. The "UMC' Universal Manifold Check is more than just a traditional stand-alone manifold. It serves as a complete floor control station as well as a complete shotgun riser assembly inclusive of Control Valve with In- ternal Supervisory Switch; Check Valve; Flow Switch; Test MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY and Drain Assembly; Adjustable Pressure Relief Valve As- sembly pre-piped to drain; supply gauge (4", 6"and 8")and system gauge (1 1/4" through 8"). The "UMC' Universal Manifold Check replaces the need to order individual "Riser SHOTGUN RISER ASSEMBLY Manifolds" plus control valves, check valves, and relief "Shotgun Riser Assemblies" are those assemblies which valve kits as all of these components are integrated into are typically installed in vertical orientations on individual the one compact design, saving space as well as the labor system Risers. The Globe "Shotgun" Riser Manifold As- to connect these separate components. For sizes 3" and sembly is available in 4 inch (DN 100), 6 inch (DN 150), smaller, an 18" long stainless steel braided flexible hose is and 8 inch (DN 200) sizes and is equipped with a control included with the UMC for connecting the Test and Drain valve; check valve; flow switch; test and drain valve with valve to a drain stack. The design takes into account both NFPA required pressure relief valve; 2 gauges (system and "left-hand" and "right-hand" orientations. (8" version avail- supply). Sizes 4 inch (DN 100), 6 inch (DN 150), and 8 inch able preassembled in right-hand orientation only) (DN 200) are equipped with a pressure gauge on both sys- tem side and supply side of the check valve clapper. The 8" UMC consists of a Universal Manifold, a Victaulic Series The UMC may be utilized to meet the NFPA 13 require- 717 Grooved Check Valve and an optional Victaulic Series ments for Floor Control Valve Assemblies where there are 705 Grooved Butterfly Valve. multistory buildings exceeding two stories in height requir- ing zoning by floor or whenever separate control and floor zoning is specified. The UMC has been engineered with space savings in mind for those commonly installed appli- TECHNICAL DATA cations in stairwell landings and small alcoves. All UMC Approvals assemblies include the NFPA 13 required Listed Pressure PP Relief Valve which is pre-piped to drain. The relief valve is • cULus preset for 175 psi and is adjustable to 310 psi for high pres- • FM sure system conditions. In addition to the relief valve, the Maximum System Working Pressure UMC is equipped with a Test and Drain Valve.The Test and • 300 psi (20.6 Bar) Drain Valve contains a test orifice of K2.8, K4.2 and K5.6 for 1", 1 1/4" and 2" respectively so that it may be utilized End Connections for flow testing any system with sprinklers having K-Factors • See Table A of that size or larger. Materials of Construction Note:NFPA 13 requires that a test connection providing a flow rate equal to or See Figure 1 less than one sprinkler of a type having the smallest orifice on the system is to be provided. A pressure gauge is provided above the check valve clap- *Multiple Patents Pending per for sizes 1'/4" through 3" to meet the gauge require- ment per NFPA 13 for Floor Control Assemblies. Typically the supply side gauge is not required for multistory build- ings with floor control stations as a system gauge would be on the main feed/riser but all Model UMC Manifold Check Valves are equipped with a 1/4" (DN 8) port below the clap- per to accommodate a second gauge if desired. AUG 2021 GFV-120 Page 1 of 14 A I 6 6 1 12 1 12 11 8 21 a9 2 9 2 15 10 14 6 0 19 3 7 18 16 17 I o fi 20 4 3 O O 13 4 aei 0 5 5 j 5 SECTION A-A I A SIDE VIEW FRONT VIEW ITEM DESCRIPTION I . MATERIAL NO. 1 I UMC VALVE BODY I DUCTILE IRON 2 RECESSED HEX PLUG I STAINLESS STEEL 3 I FLOW SWITCH I SEE FLOW SWITCH TECHNICAL LITERATURE 4 I RIGID COUPLING I SEE COUPLING TECHNICAL LITERATURE 5 BUTTERFLY CONTROL VALVE SEE GLOBE BUTTERFLY CONTROL VALVE TECHNICAL LITERATURE WITH INTERNAL SUPERVISORY SWITCH 6 PRESSURE GAUGE PLASTIC 7 THREEWAY VALVE BRONZE 8 UMC COVER PLATE DUCTILE IRON 9 BOLT STAINLESS STEEL 10 FLOW SWITCH ADAPTER DUCTILE IRON 11 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570 12 MODEL ARV ADJUSTABLE RELIEF VALVE SEE VICTAULIC SUBMITTAL 30.74 13 FLOW SWITCH PLUG DUCTILE IRON 14 UMC VALVE CLAPPER STAINLESS STEEL 15 UMC VALVE CLAPPER RETAINING BOLT STAINLESS STEEL 16 UMC VALVE CLAPPER RETAINING NUT STAINLESS STEEL 17 UMC VALVE HINGE PIN STAINLESS STEEL 18 CLAPPER FACING RETAINING RING STAINLESS STEEL 19 CLAPPER FACING EDPM 20 FLOW SWITCH PLUG BOLT STAINLESS STEEL 21 CLAPPER SPRING STAINLESS STEEL NOTE: •4"(DN100)shown as reference See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations Flow switch rotated 90 degrees on 1-1/4"through 2 1/2"sizes FIGURE 1 : MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION (1 1/4„ - 6") AUG 2021 GFV-120 Page 2 of 14 s s 1 7 1 9 7 o s a / i a O O 4 2 2 0 5 DSO o O 5 5 FRONT VIEW SIDE VIEW ITEM NO. DESCRIPTION Ilff MATERIAL 1 UM VALVE BODY DUCTILE IRON 2 SERIES 717 CHECK VALVE DUCTILE IRON BODY SEE VICTAULIC SUBMITTAL 10.08 3 FLOW SWITCH SEE FLOW SWITCH TECHNICAL LITERATURE 4 RIGID COUPLING SEE COUPLING TECHNICAL LITERATURE 5 BUTTERFLY CONTROL VALVE SEE VICTAULIC SUBMITTAL 10.81 WITH INTERNAL SUPERVISORY SWITCH 6 PRESSURE GAUGE PLASTIC 7 3-WAY SOG VALVE BRONZE 8 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570 9 MODELARV ADJUSTABLE RELIEF VALVE SEE VICTAULIC SUBMITTAL 30.74 NOTE: •See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations FIGURE 2: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION (811) AUG 2021 GFV-120 Page 3 of 14 MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY LEFT HANDED VS RIGHT HANDED Both the shotgun riser assembly and the floor control tion of the Model UTD Test and Drain determines the station assembly are available as left handed or right "Hand" of the valve. If the Model UTD Test and Drain handed assembly. The determining factor of the left is connected to the port on the right side of the valve handed vs right handed is the position of the Model body, it is considered a right handed assembly. If the UTD Test and Drain. While looking at the faceplate Model UTD Test and Drain is connected to the port on with the Model UMC valve in the vertical orientation the left side of the Model UMC valve the assembly is and flow upward (shotgun riser orientation), the posi- considered left handed. TEST AND DRAIN TEST AND DRAIN ASSEMBLY • UMC BODY ASSEMBLY b MIRRORED PORTS FOR H ALTERNATE TEST AND DRAIN LOCATIONS g o 0 FLOW SWITCH o o I NOTE:SUPPLY GAUGE """ NOTE:SUPPLY GAUGE NOT INCLUDED ON 3" 0 NOT INCLUDED ON 3" ASSEMBLY area ASSEMBLY ova 0 0 ®� BUTTERFLY VALVE FLOW FLOW LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY CONFIGURATION REPRESENTATIVE OF SIZES 3"THROUGH 6" MIRRORED FLOW SWITCH FLOW SWITCH MIRRORED PORT BUTTERFLY VALVE / PORT �LOW� ® ® I � f� B- e - O ® 4y e UMC BODY UMC BODY € 'mm b a o TEST AND DRAIN TEST AND DRAIN b ASSEMBLY ASSEMBLY --- LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY CONFIGURATION REPRESENTATIVE OF SIZES 1 1/4"THROUGH 2 1/2" FIGURE 3: MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY LEFT HANDED VS RIGHT HANDED AUG 2021 GFV-120 Page 4 of 14 TABLE A: 1'/4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/4" R GL300T MXF THREADED 1" 317800-R-B-H 24.0 (10.9) 1 1/4" R NONE MXF THREADED 1" 317800-R-H 19.0 (8.6) 1 1/4" L GL300T MXF THREADED 1" 317800-L-B-H 24.0 (10.9) 1 1/4" L NONE MXF THREADED 1" 317800-L-H 19.0 (8.6) 1 1/4" R NONE GXG 1" 317843-R-H 19.0 (8.6) 1 1/4" R GL30OG GXG 1" 317843-R-B-H 24.0 (10.9) 1 1/4" R SERIES 728 GXG 1" 317843-R-V-H 24.0 (10.9) 1 1/4" L NONE GXG 1" 317843-L-H 19.0 (8.6) 1 1/4" L GL30OG GXG 1" 317843-L-B-H 24.0 (10.9) 1 1/4" L SERIES 728 GXG 1" 317843-L-V-H 24.0 (10.9) TABLE B: 1%" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 1 1/2" R GL300T MXF THREADED 1" 317803-R-B-H 24.0 (10.9) 1 1/2" R NONE MXF THREADED 1" 317803-R-H 18.3 (8.3) 1 1/2" L GL300T MXF THREADED 1" 317803-L-B-H 24.0 (10.9) 1 1/2" L NONE MXF THREADED 1" 317803-L-H 18.3 (8.3) 1 1/2" R NONE GXG 1" 317844-R-H 18.3 (8.3) 1 1/2" R GL30OG GXG 1" 317844-R-B-H 24.0 (10.9) 1 1/2" R SERIES 728 GXG 1" 317844-R-V-H 24.0 (10.9) 1 1/2" L NONE GXG 1" 317844-L-H 18.3 (8.3) 1 1/2" L GL30OG GXG 1" 317844-L-B-H 24.0 (10.9) 1 1/2" L SERIES 728 GXG 1" 317844-L-V-H 24.0 (10.9) TABLE C: 2" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TESTAND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 2" R GL30OG GXG 1" 317806-R-B-H 26.0 (11.8) 2" R SERIES 705 GXG 1" 317806-R-V-H 26.0 (11.8) 2" R NONE GXG 1" 317806-R-H 19.2 (8.7) 2" L GL30OG GXG 1" 317806-L-B-H 26.0 (11.8) 2" L SERIES 705 GXG 1" 317806-L-V-H 26.0 (11.8) 2" L NONE GXG 1" 317806-L-H 19.2 (8.7) AUG 2021 GFV-120 Page 5 of 14 TABLE D: 2'/2" (DN65)/76.1 MM MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TEST AND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 21/2" R GL30OG GXG 1 1/4" 317809-R-B-H 31.0 (14.1) 2 1/2" R SERIES 705 GXG 1 1/4" 317809-R-V-H 31.0 (14.1) 21/2" R NONE GXG 1 1/4" 317809-R-H 23.5 (10.7) 21/2" L GL30OG GXG 1 1/4" 317809-L-B-H 31.0 (14.1) 2 1/2" L SERIES 705 GXG 1 1/4" 317809-L-V-H 31.0 (14.1) 21/2" L NONE GXG 1 1/4" 317809-L-H 23.5 (10.7) 76.1 mm R GLR30OG GXG 1 1/4" 317809-D-R-B-H 31.0 (14.1) 76.1 mm R NONE GXG 1 1/4" 317809-D-R-H 23.5 (10.7) 76.1 mm L GLR30OG GXG 1 1/4" 317809-D-L-B-H 31.0 (14.1) 76.1 mm L NONE GXG 1 1/4" 317809-D-L-H 23.5 (10.7) TABLE E: 3" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 3" R GLR30OG GXG 1 1/4" 317812-R-B-H 59.0 (26.8) 3" R SERIES 705 GXG 1 1/4" 317812-R-V-H 59.0 (26.8) 3" R NONE GXG 11/4" 317812-R-H 35.4 (16.1) 3" L GLR30OG GXG 1 1/4" 317812-L-B-H 59.0 (26.8) 3" L SERIES 705 GXG 1 1/4" 317812-L-V-H 59.0 (26.8) 3" L NONE GXG 1 1/4" 317812-L-H 35.4 (16.1) TABLE F: 4" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD SIZE CONTROL END TESTAND PART NUMBER SHIPPING R-RIGHT VALVE CONNECTIONS DRAIN SIZE WEIGHTS L-LEFT LBS. (kg) 4" R GLR30OG GXG 2" 317817-R-B 87.5 (39.7) 4" R SERIES 705 GXG 2" 317817-R-V 87.5 (39.7) 4" R NONE GXG 2" 317817-R 58.9 (26.7) 4" L GLR30OG GXG 2" 317817-L-B 87.5 (39.7) 4" L SERIES 705 GXG 2" 317817-L-V 87.5 (39.7) 4" L NONE GXG 2" 317817-L 58.9 (26.7) AUG 2021 GFV-120 Page 6 of 14 TABLE G: 6" (DN150)/165.1MM MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY APPROXIMATE UMC BODY MODEL UTD CONTROL SHIPPING SIZE R-RIGHT VALVE END TEST AND PART NUMBER WEIGHTS L-LEFT CONNECTIONS DRAIN SIZE LBS. (kg) 6" R GLR30OG GXG 2" 317818-R-B 124.5 (56.5) 6" R SERIES 705 GXG 2" 317818-R-V 124.5 (56.5) 6" R NONE GXG 2" 317818-R 80.0 (36.3) 6" L GLR30OG GXG 2" 317818-L-B 124.5 (56.5) 6" L SERIES 705 GXG 2" 317818-L-V 124.5 (56.5) 6" L NONE GXG 2" 317818-L 80.0 (36.3) 165.1 mm R GLR30OG GXG 2" 317818-D-R-B 124.5 (56.5) 165.1 mm R NONE GXG 2" 317818-D-R 80.0 (36.3) 165.1 mm L GLR30OG GXG 2" 317818-D-L-B 124.5 (56.5) 165.1 mm L NONE GXG 2" 317818-D-L 80.0 (36.3) TABLE H: 8" MODEL UMC ASSEMBLY CONFIGURATIONS ASSEMBLY UMC BODY MODEL UTD APPROXIMATE SIZE CONTROL END TEST AND PART NUMBER WEIGHTS R-RIGHT VALVE CONNECTIONS DRAIN SIZE LBS. (kg) 8" R Series 705 GXG 2" 317798-01 177 (80.3) 8" R NONE GXG 2" 317798-02 123 (55.8) AUG 2021 GFV-120 Page 7 of 14 FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00 6.00 - - 0.40 5.00 - - 0.30 4.00 lk�Nv d Q 3.000.20 W U) 0 W 2.00 --- - p /6b w o D o W `�° �p� p= 0.10 W a o� "gyp=�° 0.09 a 0.08 0.06 0.80 0.90 /- - 0.70 -- - - -- 0.05 0.60 0.04 0.50 40 50 60 70 80 90100 200 300 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4" = 6 feet • 2%" = 14 feet 6" = 30 feet • 1'/2" = 9 feet • 3" = 11 feet 8" =23 feet • 2" = 8 feet • 4" = 14 feet FIGURE 4: MODEL UMC MANIFOLD CHECK (WITHOUT BFV) FRICTION LOSS CURVES 11/4" TO 8" FLOW RATE-LPM 200 300 400 500 600 700800 1000 2000 3000 5000 7000 10000 7.00 6.00 tII 0.40 5.00 � I --- --- 0.30 4.00 - - - - ly a 3.00 ^fro ao �h 0.20 00 U) h ry W 2.00 -��"�ti. . . . �_ --- W O� (n W o p 0.10 W a oz� 0.09 a 0.08 1.00 - - - - 0.07 0.90 - --- 0.06 0.80 - - 0.70 - - _ 0.05 0.60 - - 0.04 0.50 - 40 50 60 70 80 90100 400 500 600 800 1000 2000 3000 4000 FLOW RATE-GPM UMC Equivalent Length of Piping for Friction Losses Through Schedule 40 Pipe • 11/4" = 8 feet 2'/2" = 22 feet 6" = 38 feet • 11/2" = 11 feet 3" = 17.5 feet 8" = 27 feet 2" = 12 feet 4" = 18.5 feet FIGURE 5: MODEL UMC MANIFOLD CHECK (WITH BFV) ASSEMBLY FRICTION LOSS CURVES 11/4" TO 8" AUG 2021 GFV-120 Page 8 of 14 TABLE I: MODEL UMC AND BUTTERFLY VALVE END TO END DIMENSIONS Butterfly Control Valve End to End Dimen- End to End Dimension Size Butterfly Valve Model End to End Dimension sion Without Butterfly With Butterfly Control inches (mm) Control Valve inches Valve (mm) inches (mm) 1 1/4" 2.64 10.75 12.89 MT x FT GL300T (67.9) (273) (327) GL30OG 101.E '91 1 114" ( ) 11.4 (3 ) G x G 7.25 (290) 18.65 SERIES 728 (184) (474) 1 112" 2.87 10.75 13.12 MT x FT GL300T (73) (273) (333) GL30OG 4.1 15.5 1 1/2" (104) 11.4 (394) G x G SERIES 728 7.25 (290) 18.65 (474) GL30OG 4.49 14.49 2„ (114) 10 (368) G x G SERIES 705 4.25 (254) 14.25 (108.0) (362) GL30OG 4.49 15.12 2 1/2" (114) 10.63 (384) G x G SERIES 705 3.77 (270) 14.4 (95.8) (365.8) GL30OG 4.49 15.12 65 mm (114) 10.63 (384) G x G SERIES 705 3.77 (270) 14.4 (95.8) (365.8) -7 GLR30OG 3.8 16.05 3„ (96.4) 12.75 (42 ) G x G SERIES 705 3.77 (324) 16.52 (95.8) (419.6) GLR30OG 4.5 19.13 4„ (115.4) 14.63 (486) G x G SERIES 705 4.63 (371) 19.26 (117.6) (488.6) GLR30OG 5.2 22.64 6„ (132.4) 17.44 (575) G x G 5.88 (443) 23.32 SERIES 705 (149.4) (592.4) GLR30OG 5.2 22.64 150 mm (132.4) 17.44 (575) G x G SERIES 705 5.88 (443) 23.32 (149.4) (592.4) 8 SERIES 705 5.33 27.0 32.71 G x G (135.4) (685.4) (830.4) AUG 2021 GFV-120 Page 9 of 14 ® c ®LL e0 *Dl LL 4 = 0A B D GB C E A C E A B C D E F G H I SIZE Inches Inches Inches Inches Inches Inches Inches Inches Inches (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 1 1/4"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/4"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 (79) (157) (214) (150) (170) (301) (50) (290) 1 1/2"TXT 3.1 6.2 8.4 6 6.7 13 2 10.7 9.5 (79) (157) (214) (150) (170) (328) (50) (272) (241) 1 1/2"GXG 3.1 6.2 8.4 6 6.7 11.9 2 11.4 (79) (157) (214) (150) (170) (301) (50) (290) 2„ 3.9 5.4 7.6 6 6.8 11.9 2.1 10 (99) (136) (193) (150) (173) (301) (53) (254) 2 1/2" 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 (84) (171) (233) (157) (182) (312) (58) (269) 76.1 mm 3.3 6.7 9.2 6.2 7.2 12.3 2.3 10.6 (84) (171) (233) (157) (182) (312) (58) (269) FIGURE 6: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 11/4" TO 21/2" Q o i % F P O O H LL 2 J A o B A-� ID � �C E j G 311-C,' Q„ A B C D E F v G H SIZE inches inches inches inches inches inches inches inches (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 3" 6.5 6.9 9.4 _ 6.4 16 2.4 12.7 (165) (176) (238) (161) (406) (61) (324) 4" 7 8.3 11.2 5.6 7 17.7 3 14.6 (177) (210) (284) (143) (178) (449) (76) (371) 6" 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 165.1 mm 8 9.5 12.4 6.4 7.9 19.9 3.9 17.5 (203) (241) (315) (163) (201) (504) (99) (444) 6.5 8.38 11.25 10.6 6.0 29.62 27.18 8 (165) (213) (286) (269) (152) (752) NA (690) FIGURE 7: MODEL UMC ASSEMBLY WITHOUT BFV DIMENSIONAL DRAWING FOR SIZES 3" TO 8" AUG 2021 GFV-120 Page 10 of 14 FLOW SWITCH REQUIREMENTS The Model UMC Floor Control/ Shotgun Riser assembly is in the replacement parts section of the technical literature. sold inclusive of a Potter VSR flow switch. The flow switch The Potter VSR Flow switch includes 2 sets of switches, utilizes exactly the same electrical and switch components one set can be used to activate the central fire alarm system as the Potter VSR flow switch but includes an adapter which while the other set can be utilized to activate a local alarm (if attaches directly to the Model UMC Manifold Check as- necessary). See figure 8 for a typical wiring diagram for the sembly. This adapter has been tested as part of the UMC Model VSR Flow switch. assembly to ensure the hydrostatic strength as well as the placement and sensitivity of the paddle is within the criteria Note:For more information on the flow switch see wwwpottersignal.com. set forth by UL and FM. The part number for the flow switch assembly can be found WIRENUT LOCAL WIRE NUT FIRE PANEL OR AUDIBLEMSUAL ADDRESSABLE ANNUNCIATOR MODULE NEUTRAL F W WHITE WHITE BLACK U% BLACK (LINE/HOT) P.0 r < 0 m J 0 0¢a 0 U O 2 s m O D wuw wierum �� .xev. xa xo FIGURE 8: MODEL VSR-M FLOW SWITCH TYPICAL WIRING DIAGRAM RED — RED S-1 FIRE ALARM COMMON (WHITE) I I COMMON (WHITE) CONTROL PANEL END OF LINE SUPERVISORY YELLOW YELLOW RESISTOR CIRCUIT GREEN I OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC GEAR OPERATOR) ORANGE I S-2 COMMON (BLACK) BLUE VOLTAGE AUX. DEVICE SOURCE ______________________________ (BELL/HORN) VALVE WIRING SHOWN WITH VALVE IN OPEN POSITION FIGURE 9: GL300T, GL300G, AND GLR30OG BUTTERFLY VALVE WIRING DIAGRAM AUG 2021 GFV-120 Page 11 of 14 - -1 L(F__ .FIRE ALARM COMMON (YELLOW) I COMMON (YELLOW) CONTROL PANEL END OF LINE SUPERVISORY BLUE BLUE RESISTOR CIRCUIT GREEN I OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC GEAR OPERATOR) BROWN/ORANGE II S-2 I COMMON (YELLOW/ORANGE) BLUE/ORANGE VOLTAGE AUX. DEVICE SOURCE ______________________________ (BELL/HORN) VALVE WIRING SHOWN WITH VALVE IN OPEN POSITION FIGURE 10:SERIES 728 AND 705 BUTTERFLY VALVE WIRING DIAGRAM SWITCH AND WIRING 1. The supervisory switch contains two single pole, double throw, prewired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the"OPEN"position. 4. One switch has two#18 insulated wires per terminal,which permit complete supervision of leads(refer to diagrams and notes below).The second switch has one#18 insulated wire per terminal.This double circuit provides flexibility to operate two electri- cal devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5. A#14 insulated ground lead (green)is provided. Switch#1 =S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2 =S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 Normally Closed: (2)Blue Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe AUG 2021 GFV-120 Page 12 of 14 INSTALLATION TESTING The Model UMC Floor Control/ Shotgun Riser assembly is Reference NFPA 25, Standard for the Inspection, Testing sold as a complete unit, assembled and shipped in a single and Maintenance of Water-Based Fire Protection Systems. box. Before proceeding with any tests involving water flow, the The Model UMC Manifold Check Valve must be installed in following precautions need to be taken: an accessible and visible location, which is maintained at STEP 1. Check the location where the test connection or above a minimum temperature of 40°F (41C). The UMC discharges to make sure that all is clear and may be installed in the horizontal or vertical (flow upward) that there is no possibility of the water flow orientation. causing damage or injury. All valves must be installed in accordance with the ap- STEP 2. Check the end of the test connection to make propriate installation standard (i.e. NFPA 13 or other). All sure that it is unobstructed. To achieve a satis- electrical connections must be made per the applicable in- factory test, there must be an unrestricted flow stallation standard and/or the National Electric Code (i.e. of water when the test valve is wide open. NFPA 70, NFPA 72 or other). STEP 3. Check for alarm connections to a central sta- Proper hydrostatic test procedure must be followed per tion or fire department. If such connections are NFPA 13. found, give proper notice to the signal receiv- It is not necessary to remove the ARV Relief Valve prior to ing station before proceeding with the test. system hydrostatic test. The Adjustable ARV may simply Note:A main drain test may also operate local fire alarms unless they are tem- be temporarily adjusted to a pressure above the test pres- porarily disabled. sure during the hydrostatic test. Be sure to return the ARV Relief Valve to it's normal setting after the completion of the hydrostatic test. MAINTENANCE The owner is responsible for the Inspection, Testing and MODEL ARV RELIEF VALVE Maintenance of their fire protection system. SETTING PROCEDURE System inspection, testing and maintenance shall be per- formed in accordance with this section as well as NFPA 25 The Globe 1/2 inch Model ARV, 300 psi Adjustable Pres- or other applicable Standard to insure the integrity of the sure Relief Valve, is factory set to relieve at a pressure of entire system, including alarm functions as well as other approximately 175 psi (12 bar). system components. Any impairments must be immedi- The Pressure Relief Valve may be reset to a higher pres- ately corrected. sure; however, it must be reset to relieve at a pressure Before closing a system main control valve for mainte- which is in accordance with the requirements of the au- nance work on the fire protection system, obtain permis- thority having jurisdiction, typically nominal 10 psi (.7 bar) sion to shut down the affected fire protection system from above the expected normal system pressure. the proper authorities and notify all personnel who may be To reset the Model ARV pressure relief valve, use an ad- affected. justable crescent wrench, to turn the hex cap clockwise for Note: a higher pressure setting or counter-clockwise for a lower All valves should be carefully inspected,tested,and maintained in accordance pressure setting. Use the calibrated lines on the stem for with NFPA 25 or other applicable Standard. an approximate relief pressure setting. 1 full turn of the It is important to ensure a clean water supply free of debris hex cap will result in approximately 25 psi increase or de- and solid particles such as sand, gravel, or mud. crease. To verify the new setting, isolate the Model ARV relief valve If, during an inspection of a water control valve, sediment and use a small hydrostatic pump attached to the supply. or free particles of matter are noted, a further examination Increase the pressure at the relief valve to 10 psi above of internal valve parts is necessary. the expected normal system pressure. Readjust the ARV All deposits should be removed from all operating parts and as needed to maintain a 10 psi higher relief setting. ports. Where difficulty in performance is experienced, the manu- facturer or its authorized representative shall be contacted before any field adjustment is to be made. UMC Clapper Facing.The rubber clapper facing should be checked for wear or damage and to determine that it is free of dirt and other foreign substances. If found to be worn or damaged (e.g., foreign matter embedded in the surface; cut or torn facing), the facing should be replaced. If it is dirty, it should be cleaned. Compounds which could dam- age the rubber facing must never be used. Should clapper facing replacement become necessary, the following steps should be performed; Note:Before performing the following steps, insure that the system has been depressurized and drained. Clapper Removal STEP 1. Remove handhole cover. STEP 2. Remove hinge pin plugs from front and back of UMC. STEP 3. Using allen wrench, push hinge pin from back of UMC towards front. AUG 2021 GFV-120 Page 13 of 14 STEP 4. Once hinge pin is accessible, carefully grab REPLACEMENT PARTS with pliers or similar to pull hinge pin out of body. MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE Note:Care must be taken to confine clapper spring while extracting hinge pin REPLACEMENT PARTS/KITS from body.Spring is under tension around hinge pin. It is also recommended to cover drain port to minimize the possibility of spring inadvertently dropping VSR-M FLOW SWITCH with ADAPTER (includes gas- into drain piping. ket) STEP 5. Carefully remove clapper assembly from UMC. SIZE PART NUMBER Clapper Replacement. When replacing clapper, be sure 11/4' - 2" . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144802-A-G clapper spring has been properly positioned around hinge 2'/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144825-A-G pin such that tension is applied to the clapper by the spring. 3... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144803-A-G 4... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144804-A-G Seat Ring. The seat ring should be checked for nicks and 6" 91144806-A-G for stones, dirt or other foreign matter. It should be cleaned thoroughly. If the seat ring is found to be damaged, UMC 8... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91144808-A-G should be replaced. MODEL UTD TEST AND DRAIN Water Flow Switch (VSR-M). There is no maintenance re- (SEE GFV-570 for more information) quired, only periodic testing and inspection. Should switch Specify: MODEL UTD TEST AND DRAIN WITH RELIEF be found to be malfunctioning, refer to Potter Signal Techni- VALVE,SIZE (1", 11/4", or 2") PN: cal Literature for guidance. SIZE PART NUMBER Model ARV Adjustable Relief Valve. Valve is not field ser- 1, (DN25 . . . . . . . . . . . . . . . . . . . . . . . . . S01 OUTDGAO viceable. If inadvertent leakage is observed, first test the 1/4 (DN32). . . . . . . . . . . . . . . . . . . . . . . . . S012UTDGAA pressure setting utilizing the procedure outlined in the ARV 2" (DN50). . . . . . . . . . . . . . . . . . . . . . . . . S020UTDGA4 Relief Valve Setting Procedure. If valve does not respond Specify: MODEL UTD TEST AND DRAIN,SIZE (1", 11/4", or to field adjustments, valve shall be replaced. 2") PN: Note: SIZE PART NUMBER Visual calibration lines on valve are used for approximate adjustment. Verify 1" (DN25). . . . . . . . . . . . . . . . . . . . . . . . . S01 OUTDGAO pressure setting with pressure gauge. 1'/4'(DN32). . . . . . . . . . . . . . . . . . . . . . . . . S012UTDGAA Model UTD Universal Test & Drain Valve: The Globe 2" (DN50). . . . . . . . . . . . . . . . . . . . . . . . . S020UTDGA4 Model UTD Universal Test and Drain Valve does not re- quire any regularly scheduled maintenance. The UTD is not field serviceable. MODEL ARV RELIEF VALVE (SEE Victaulic 30.74 for more information) Specify: MODEL ARV 1/2"ADJ RELIEF VALVE PN. ORDERING INFORMATION . . P0047470PR Note: MODEL UMC UNIVERSAL MANIFOLD CHECK VALVE ASSEMBLY 300 psi(20.6 Bars)Pressure Gauges Standard(600 psi(41.2 Bars) Ordered Specify: MODEL UMC MANIFOLD CHECK VALVE Separately ASSEMBLY,SIZE (11/4", 1%", 2", 2'/z", 76.1 mm, 3", 4", 6", PN......................................300121-D 165.1 mm, 8") PN (see Part Number in Table A-G) Note: Control Valve Model based on availability at time of order. See appropriate GLOBE® PRODUCT WARRANTY Tables for end-to-end dimensional information. Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 •989-846-4583•www.globesprinkler.com • Technical Support•989-414-2600•techservice@globesprinkler.com AUG 2021 GFV-120 Page 14 of 14 EDDY F r � AlwaVs reaft to protect Vour most valuable assets. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product information O.D.(in) 1.660 1.900 2.375 2.875 3.500 4.500 I.O.(in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty weight(Ib/ft) 1.222 1.844 2.330 2.809 3.361 4.968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 Lift Weight(Ibs)21'lengths 1,565 2,362 1,810 1,770 1,341 1,982 Lift Weight(Ibs)24'lengths 1,789 2,700 2,069 2,022 1,533 2,265 Lift Weight(Ibs)25'lengths 1,864 2,812 2,155 2,107 1,596 2,360 r 1� EDDY FLOW ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved We have the most stocking locations in the industry, • ASTM A135 and A795 Type E,Grade A Certified for best delivery and availability • Complies with NFPA-13,13R and 14 Plain end or roll groove •• Industry-leading hydraulic characteristics Eddy Guard II'"bacterial-resistant internal coating • Custom length options • CRR of 1.0 and greater Hot dipped galvanization • All pipe NDT weld tested Reddi-Pipe°red or black pipe eliminates field painting • Compatible for use in wet,dry, preaction and deluge sprinkler systems ■Exclusive maker I ■ I 1I D O■ BLAEK PAINTED PIPE. The only maker with EPDs(to help earn LEED points). c us LISTED <*> M#�# IYNFSA APPROVED IrFPiA va, 800.325.4467 sales@BullMooseindustries.eom -Imff muse ■ As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. ' ' I I Ir O.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.660 1.900 2.375 2.675T758010.800 I.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 — 7.380 7.670 2.067 2.469 Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 2.270 2.720 3.660 5.800 Water Filled Weight(Ib/ft) 1.820 2.516 3.053 4.223 5.893 1.957 11.796 23.038 40.066 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 15.27 9.91 7.76 5.27 4.92 3.54 2.50 1.158 1.805 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 91 61 61 37 30 19 19 10 7 51 44 30 30 19 19 Lift Weight(Ibs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weight(Ibs)24'lengths 3,019 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,846 2,178 2,872 2,635 4176 3456 4,925 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,894 2,992 2,745 4.350 3.601 5,130 SCHEDULE 10 R 40 ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved We have the most stocking locations in the industry, • ASTM A135 and A795 Type E,Grade A Certified for best delivery and availability • Complies with NFPA-13,13R and 14 Plain end or roll groove •• Industry-leading hydraulic characteristics Eddy Guard II'"bacterial-resistant internal coating •• CRR of 1.0 and greater Custom length options • Hot dipped galvanization • All pipe N DT weld tested Reddi-Pipe°red or black pipe eliminates field painting • Compatible for use in wet,dry,preaction and deluge EXCIusiv maker I I 1 ' I sprinkler systems .D OR BLAEK PAINTED PIPE. The only maker with EPDs(to help earn LEED points). c us LISTED FM �► 01, ONFSA APPROVED IIIPPK �� ,�1 800.325.4467 sales@BullMooseindustries.com Y : I T Rff UPON ODTOLCOO www.tolco.com 00: Fig. 200 - "Trimline" Adjustable Band Hanger C@ USLlsren Fig. 20OR (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. ® "-- Features — _ • (1/2" thru 2") Flared edges ease installation for B `I B all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. A • 1 " u ------ securely/2 thru 8 Spring tension on nut holds it ;y_ ( ) P 9 securely in hanger before installation. Adjusting nut is easily removed. Fig.20O 1"-2" Fig.200 21/2"-8" Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA(UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual ` Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and -------- Manufacturers Standardization Society SP-69, Type ® - 10. B Maximum Temperature — 650OF B Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size A Note — Figure 20OR (import) with retainer ring and A non-captured knurl nut. --- Fig.20OR 21/2"-8" Fig.20OR 1/2"-2" Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 m CUSTOMER SERVICE•800.786.5266 www,tolco.com BRONZE BUTTERFLY VALVE - GROOVED "BUTTERBALL" ARbCO SINCE © 1981 ��� • Connections: Grooved Ends (AWWA C606) - - • Sizes: 1", 1-1/4", 1-1/2", 2", 2-1/2" 3" • Approvals: UL, ULC, FM • Maximum Working Pressure: 30OPSI (Max. Test Pressure: 60OPS1) • Maximum Working Temperature: 250°F (120°C) • Application: Indoor and Outdoor Use • Factory-Installed Supervisory Tamper Switch Assembly 1 37 C @US C FM OS LISTED APPROVED � ---I--- - MATERIALS Components Material Specification Body Bronze ASTM B505 Disc Aluminum Bronze ASTM B548 Disc Encapsulation EPDM Rubber ASTM D2000 Indicator Brass ASTM B16 Housing Steel ASTM A619 Handwheel Steel ASTM A619 Stem Stainless Steel ASTM A564 Type XM1 K-7 DIMENSIONS Item # Size A B C D E F6520291A 1-1/4" 3.9" 1.7" 1.5" 0.6" 0.3" 2.2" 6520292A 1-1/2" 4.1" 1.9" 1.8" 0.6" 0.3" 2.3" 6520294 1 2" 4.5" 2.4" 2.2" 0.6" 0.3" 2.5" o 6520296 2-1/2" 4.5" 2 9" 2 7" 0.6" 0.3" 2 9" System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com i(ARGCO Updated 3/10/2022 ©ARGCO ARGCO. 60 T-1015 BRONZE BUTTERFLY VALVE - GROOVED "BUTTERBALL" UPOR © WIRING DIAGRAM SWITCH SHOWN POSITION WITH VALVE IN FULL OPEN SWITCH 1 : DUAL LEADS SOLDERED TO SWITCH TABS BLACK SUPERVISORY TO NEXT INDICATOR CIRCUIT OF A OR LISTED FIRE ALARM NC END-OF-LINE RESISTOR CONTROL PANEL WHITE COMMON 1 NO RED SWITCH 2: SINGLE LEADS SOLDERED TO SWITCH TABS ORANGE AUXILIARY EQUIPMENT NC VOLTAGE BLUE SOURCE COMMON NO YELLOW Green wire is provided as ground for the switch housing. Switch rating: 10.lAmps-125/250VAC-60Hz Actual switch application rating: 10 Amps/115 VAC-60Hz,0.5 Amps/28 VDC SUPERVISORY TAMPER SWITCH (FOR INUOORIOUTDOOR USE) 112'ELECTRICAL CONDUIT O m-o w m � q® 0 0 0� 0 CD ormyo 0az y 0 M O LUL LISTED JUNCTION aOX Installation must comply with NFPA 13 and NFPA 72. Cap unused leads with wire nuts and tuck into a junction box(not provided). System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com ARGCO Updated 3/10/2022©ARGCO AGOO.— e00_a54_1015 �i MI■I E LU M �,�•� ■I■I � x m 1�■N.N�■nnNYn1111111.....■■■■■■■■■■■■�nn111111 n1■■■■■■■■N■■■M... • �aN����1111111111111■11■■■■■■■�gY111111N1■■■■■■■pqq■M... w\`�pN����11111111111■■■■■■■■■■qqp gn111111 N1111■■■■p■■■..... M�`'�p��=�11111111111111111�1■■ggYgn111111N111■■■■■p■qqH=■■ • wY1w��p1��11111111111■111■■■1■1lgpgn111111■11111■■■NggqN..■ • s1= -_:a=ma:RIMI=IEEE°:eee'se;s=55■e5:s:■.::":eeee':e•111ee::191 I:�A�I��:�I���:.ii::::::ii•ii11■Itii 111122,023NNN • .oN..•....•uN���w nuwoauoou N���A�NNA • ANI�NN�NA��:::.■.►.i.....■•■...■■■�tl NH:::■■.N•.�•.■■w NtltltlM... ANI�NNNNN��I......■►w ■•.••••••■■tlN NN1■■■■■N■■••••■•N■■■MINNN N������N�A.III■■■■■■■►��■■■■•■■■■■N II1Nsa...p■■■■■■.■�.tltlA■NNN NNI�NNNNN�M IN111111111■EN 1:....■■N■1.11111■■■■■■■•.•.■.■■■M... N��N�Nn■■.I..11111■■lN 1■1A�..■..■■■n■111.1111 NN.■..■.N■■■MN.. Nib..■�NN..n�1111111111111.1■■��..■■N 1n11111■1.■.......�.tltl N... LL NNlnl■MN�Nn■��III1I n■111■1.1■...�7■■ntl11n111111 N.....■.. ■■■Man . w•■.NI�0102SCmummuuuo 10401 unuannoopo■Mmom • nl•mmmm�■� mxnuuun..nu■►�nnnu.n.nuuua■■■M... ■IiiiNNNI.■ ■i11111111■11...■.■■■■■■■■\!.N1111.1..■■■■■..N■■■Y.... • w�pNN����111111111111■1■1■■■■■■■NI■i�11111H■■■■■■■■NY■q■.... M�q.gN��gqlN■1111111111 Islas 1■■■■■ggaq111.:�11N1111■■■■N■■■Y.... • •• ■■�p�p�pl�gg1111111111111111111111ggqq 111111111:V 11■■■■■■pggq■■■■■ M�pppplpl�gg111111 vigil 1111111111 mom�11n111111 M:g11111■pggq■■■■■ Mglpppp pl��11111111111111111111■lpmq g11111111g11�:�1111pppmm■■■■ M■■q■ ��1111111111111111111111gw RRIIIIII MINOR pomp■■■■■ ■■■MMMMEM1111111111 Hill 11111 Moon m■111111■111111ok6 9100M■■■ ■_■■■■■mmm m11111111111111111111moo=RNllllll■111111111pkiz\■■■■■ • ■■■w■■■��IIIIIIIIIIIIIIIIIIII�Noon NI■IIIIIIINIIIIIIII�■�■B�■ • Q� N■N■■■��IIIIIIIIIIIIIIIIIIIII■■■N■111111■11111111■■■■N■■ki c �■■1■■■■��IIIIIIIIII111111111111■■■NIIIIIIIIIIIIIIII■■■■■■■■■ •� Ii Y■IN■■■■��IIIIIIIIIIIIIIIIIIIIII■■Inllllll■11111111■111■■■■■ � � �■�■■■■■IIIIIIIIIIIIIIIIIIIIIII■111111111■11111111■IIIn■■■ ■■�w■■■■■IIIIIIIIIIIIIIIIIIIIIII■IIIIIIIIIRIIIIIIII■111®��� � ■■N■■■■■IIIIIIIIIIIIIIIIIIIIIII■IIIIIIIIIIIIIIIII■111■111 ■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■111111111111111111■111■111 o i 1�■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■111■111 _■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■111■111 • '� � '_=====EeeEeEee'E6eeeeeeEee: eeeeeeeee 'e::e5 :__==== • C AAAIAINN__A.��_.................•...����n........N........N���M�== • �_AA AINN�A.A�AN...............•.....��A n.........•.•••....N.��M�NN �I NiiNNtl��N�ANI.......N11.•.•..•..�tlN tlY.....■N..•••...N.■tltltl�N� •• NiiN�NNNNNN I.I........•.•....■..■■N tl.......■A..••....■tltltl■tltl.NN NNINNI�NN.NNIIIII1.N111111.......�N■11I1111111111.....N■■■MNNN � NiiN�NNN.NN II11I I11111.■111.....■■N In1I1111111111.....p■■■■..NN N/iNN�NNNNNNx111 IN111N1..1.111..■11.1........■■■■■N n1111111.....M■■■MNNN • YiiNN■��N�ni 11111 N tl NNxtlllllll N..■■.....■■■tlMNN. .��nn.�n■Nln.nn1111111n1.1...■...■.■■■■n nn1111.1N........N■■■M... • • D v w�nM.�Nn■n...1111111n1 n.....■...■■■n nlllll■111......■■■.■■■■M... ■��.N�NNMnn1111111111111■...■■■..■■■n xnllnll l.........■■■■■M... • • � ■�i■n.��N1��1111111■.11■■1.....■■■■NIIYII■1■111.■.......■■■■M... • w��NN■■■.��11111111111111■■■■■■■■■NI NY111111.11■■■■■■■■■■Yq.... �C�pZ�S�111111111111IIII111I11C■RIIIIIIIIIIIIIIIIIC�=:::IIS CL S r�Ap�pl�gg1111111111111111111111gqY1111111111q11111111ppqq■■■■■ • s �axo211 a:o:x:::I:::ZIECti-XIC �ZIiCmam ........ ......1 ..........C�■_■a li NAIAINNNN\��II...........••.....■■■�.N......NA........N���N■NNN Nii�NI��N��I......1111111......■■tlN I11......■q11•.....YtltltlNI.NN Niii��NN.N.\�.'1II I111....111.......tltl I1tl111.1111111.....N■■■...NN NiiNN■�NNNY�`�1111111 N■.■1.....■■N xtl111111 N..1......■■■■..NNN Niii��NNNtl�fI.`�11111111..11....■■N tlx111111 N........■■■tl■MNNN ■i IInI' 1�1■... ■.. ■■■1111NI 11 ■qp■ ..■ A ■■M. ■TT.■■N1:a 1111111._.11..ii...0 C1■N■Illlllll l..iii.■.0 n.Z■.M.�■ w u■ Ym mn ■ ■ Y. 1■=��■:�1■�I:II...11::_:, .iliii7■■Salt:plYll.11.gp.l..iilis.■iw.;.=IM=■*■■ . • ■��p��q■■�11111�111 I��������Q\I�pgH IIIIIB���I�1�11q�li�q�q��■ P • w�Np�pI�YN111111111111111111111��gg11111111N11■■■111p■qqM■■■ ZF +a M■ppp����111111111111111111111pm��gn111111■11111111pppmN■■■ � 1`+ Mml■Ipp����111111111111111111111ppN®g111111g11111111pppmmm■■■ 4 • MOMlppl�m■m■111111111111111111111pmmmg111►.VI■11111111pmmmm■■■■ 7.� � ml■■mm■���mmlm■11111111111111111oo11pNEM IIm11111:!1�1111111 ppmmm■■■■ C • ■ml■■�m■m■m■111111111111111111111pmm11m111111H■:�IIp11Npm■■■■■■ v • ■ ■����111111111111111111111pmq■■111111■111�:!IlBpmmN■■■ • IZ Mu w r■�■■���IIIIIIIIIIIIIIIIIIIp1■■■■■IIIIIINIIIII���\■■■■■■■■ ■■■u■■■��111111111111111111111■■■g■g11111111gq11111111�:�■N■■■ p O x r • ■■■■■■■ ■I�IIIIIII���1111��1�11 ■IIII INIIIIIII�■1���1��� U ■■■N■■■■■IIIIIIIIIIIIIIIIIIII111■I■IIIIII■11111111■111■■■■ � o o N . ■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIINIIIIIIII■111n��� ■■N■■■■■IIIIIIIIIIIIIIIIIIIIIII■NNIIIIIIIIIIIIIII■111NIII ~N ■■■■■■■■IIIIIIIIIIIIIIIIIIIIIII■INIIIIIIIIIIIIIII■11111111 � '��= � '� ■�■■■■■■IIIIIIIIIIIIIIIIIIIIIII■11111111111111111■111■111 = 1��■■■■■■IIIIIIIIIIIIIIIIIIIIIII■11111111111111111g111■111 . Ln .. z � Eg • an, ONO - • • W .E. �� • I Q .. • From: Permit Office To: LaNav Pray Subject: RE: Expiration Notice BLD6497 Date: Thursday,February 5,2026 1:50:12 PM Attachments: image002.png imaae003.ona This message is from an External Sender This message came from outside the City of Arlington Hello! We are needing to extend this permit, please.We are going to be starting the installation on 2/20/26, but I don't want to take the risk of not finishing enough for an inspection before 3/31/26. Please feel free to reach out for any additional information that is needed, thank you. Pay MyAFP Systems Bill Online Micaiah Stewart Project Administrator Phone:503-692-9284 Mobile: 971-413-4383 Fax:503-692-1186 19435 SW 1291h Ave WTualatin,OR 97062 O www.afpssys.com SYSTEMS Pay MyAFP Systems Bill Online 0 PRO CCBOR#67534 WA#AFPSYI*091 BZ CA#936000 NV#84686 ID#RCE-37372 From: LaNay Pray<Ipray@arlingtonwa.gov> Sent: Monday, February 2, 2026 12:36 PM To: Permit Office<permits@afpsys.com> Subject: Expiration Notice BLD6497 Hello, This email is to inform you of the upcoming expiration date for permit BLD6497. This permit will expire on 3/31/2026. Please ensure that an inspection has been requested and approved prior to the expiration date. If you are not ready an inspection prior to the expiration date, please reply requesting an extension. The request needs to state cause for the extension and requires approval by the Building Official once received.Additional fees may be required upon extension approval. Please use the link below to view and request an inspection.You can also call in an inspection at 360-403-3417. Permits -Arlington (iworq.net) Sincerely, I OLaNay Pray Community&Economic Development,Permit Technician I 18204 59th Ave NE,Arlington,WA 98223 0:360.403.3437 112ray0arlingtonwa.gov I www.arlingtonwa.gov Note:Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act.