Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20100 71st Ave Ne_BLD5283_2026
COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 This application is for new,addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration ❑ Replaced ❑✓ Gas Piping Type I and Type 11 Hood Systems required submittal of the Commercial Mechanical Addenda Property Address; 20100 71 st Ave NE Arlington Project Valuation: $5,000.00 Lot#: Parcel ID No.: 00793300000501 Preferred Contact: O Owner O Contractor Project Description: One Gas line for 48kW Gen Set 100% Load 730,000 cubic feet/hr Owner Name: AMT NW/Senior Aerospace Office No.: 3608992009 smcglothern@amtnw.com Email Address: Cell Na.: Mailing Address: 20100 71st Ave NE City: Arlington State: WA zip:98223 Arlington Electric, Inc. 360-403-0515 Contractor Name: Office No.. Email Address: arlingtonelectric@msn.com Cell No.: 13310 240th St NE Arlington WA 98223 Mailing Address: City: g State: Zip: L&I Contractor License Number: ARLINE1822BJ Expiration Date: 01/11/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS, Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable 0 CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" 0 5/s" 3/4" 0 1" O l Yz" O 2" Inlet Pressure: 7-12" W.C. Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $75.00 = $ Air Cond.Unit 5100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h x $25.00 = $ Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $25.00 $25.00 Boiler<100Btu/h>3h x $15.00 = $ Boiler>1 million Btu/h<50hp x $25.00 = $ Boiler>1.5 million Btu/h<50hp x $50.00 = $ Boiler>100Btu/h 3-15hp x $ 15.00 = $ Boiler>500Btu h 15-30hp x $25.00 = $ Commercial Hoods-Type I x $25.00 = $ Commercial Hoods-Type If x $50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat s100 Btu x $ 15.00 = $ Forced Air Heat>100 Btu h x $25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC s100 Btu h x $ 15.00 = $ Gas Fired AC>100 Btu h x $25.00 = $ Gas Fired AC>500 Btu x $50.00 $ Gas Pi in s 5 units 1 x $ 15.00 = $15.00 Gas PiRing> 5 units (plus<5 units x $2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by 1 x $ 15.00 _ $15.00 mechanical code,not otherwise specified Pkg.Units s100btu x $25.00 = $ Pkg.Units>100btu x $50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu/h x $25.00 = $ Refrigeration Unit>500Btu h x $50.00 = $ Re-inspection fee all x $75.00 = $ Unit Heaters:5 100 Btu h _ x $ 15.00 = $ Unit Heaters>100 Btu h x_ $ 25.00 = $ VAV Boxes (Variable Air Volume, part of air $ 10.00 $ conditioningsystem) x Wall Heaters-Gas Fired x $25.00 = $ Water Heater-Gas Fired x $25.00 - $ Permit Fee $55.00 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $80.00 REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Lengths) from meter to all appliances NOTE: Any interior pressure regulators must be indicated 11 4- 0 61oLk k�/x�01j � tl �(o —r I hereby certify that Iam the❑Owner, ❑Applicant,,Ri!!!antractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A f[nal inspection and approval shall be obtained when complete. W 7—Z)IU Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of3 GENERAC` 0 Protector PROTECTOR° SERIES _ Series Standby Generators Liquid-Cooled Gaseous Engine OEM_ INCLUDES: Standby Power Rating Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz • Two-Line LCD Multilingual Digital Evolution" Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Controller(English/Spanish/French/Portuguese) Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz with external viewing window for easy indication of Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz generator status and breaker position. Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz • Capability to be installed within 18 in (457mm) of a building* • True Power"" Electrical Technology GENERAC • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger =_ • UV/Ozone Resistant Hoses = — • ±1%Voltage Regulation sumn6imoNow • Natural Gas or LP Operation • 5 Year Limited Warranty O�T�lus• UL 2200 Listed QUE-Eff- 'a::em°iea m me usn esng Note: 25-45 kW units are field convertible *Only if located away from doors, between natural gas or liquid propane. 60 kW windows,fresh air intakes,and unless Meets EPA Emission Regulations units are built per fuel requirement and are not otherwise directed by local codes. 25,30,&45 kW meet CA/MA emissions compliant convertible. Applicable for 25 kW and 30 kW units only. 36&60 kW not for sale in CA/MA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it REGULATION. This state-of-the-art power maximizing regulation doesn't stop there. Total commitment to component testing, reliability system is standard on all Generac models. It provides optimized FAST testing,environmental testing,destruction and life testing,plus testing to RESPONSE to changing load conditions and MAXIMUM MOTOR applicable CSA, NEMA, EGSA, and other standards, allows you to STARTING CAPABILITY by electronically torque-matching the surge choose GENERAC POWER SYSTEMS with the confidence that these loads to the engine.Digital voltage regulation at±1%. systems will provide superior performance. O TEST CRITERIA: O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive ✓PROTOTYPE TESTED ✓NEMA MG11-22 EVALUATION dealer network provides parts and service know-how for the entire unit, ✓SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY from the engine to the smallest electronic component. O MOBILE LINK`!' CONNECTIVITY: FREE with all RG generators, Mobile O GENERAC TRANSFER SWITCHES. Long life and reliability are Link Wi-Fi allows users to monitor generator status from anywhere in the synonymous with GENERAC POWER SYSTEMS. One reason for this world using a smartphone,tablet, or PC. Easily access information such confidence is the GENERAC product line is offered with its own transfer as the current operating status and maintenance alerts. Users can systems and controls for total system compatibility. connect an account to an authorized service dealer for fast,friendly,and proactive service. With Mobile Link, users are taken care of before the next power outage. GENE® 14 GENERAC® 25 • 30 • 36 • 45 60 kW application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 25& 30 kW Type Synchronous Make Generac Rotor Insulation Class H Model In-line Stator Insulation Class H Cylinders 4 Telephone Interference Factor(TIF) <50 Displacement(Liters) 1.5 Alternator Output Leads 1-Phase 4 wire Bore(in/mm) 3.05/77.4 Alternator Output Leads 3-Phase 6 wire Stroke(in/mm) 3.13/79.5 Bearings Sealed Ball Compression Ratio 11:1 Coupling Flexible Disc Intake Air System Naturally Aspirated Excitation System Direct Litter Type Hydraulic VOLTAGE REGULATION ENGINE SPECIFICATIONS: 36,45, &60 kW Type Electronic Make Generac Sensing Single Phase Model In-line Regulation ±1% Cylinders 4 GOVERNOR SPECIFICATIONS Displacement(Liters) 2.4 Type Electronic Bore(in/mm) 3.41/86.5 Frequency Regulation Isochronous Stroke(in/mm) 3.94/100 Steady State Regulation ±0.25% Compression Ratio 9.5:1 Intake Air System Naturally Aspirated(36&45 kW)or ELECTRICAL SYSTEM Turbocharged/Aftercooled(60 kW) Battery Charge Alternator 12 Volt 15 Amp—25&30 kW Lifter Type Hydraulic 12 Volt 30 Amp—36,45,&60 kW Static Battery Charger 2Amp ENGINE LUBRICATION SYSTEM Recommended Battery(battery not included) Group 26,525 CCA Oil Pump Type Gear System Voltage 12 Volts Oil Filter Type Full flow spin-on cartridge Crankcase Capacity(qt/1) 4/3.8-25,30,36,&45 kW GENERATOR FEATURES 5.25/4.96—60 kW Revolving field heavy duty generator ENGINE COOLING SYSTEM Directly connected to the engine Operating temperature rise 120°C above a 40°C ambient Type Closed Class H insulation is NEMA rated Water Pump Belt driven All models fully prototyped tested 2,484—25&30 kW ENCLOSURE FEATURES Fan Speed(rpm) 1,865-36&45kW Ensures protection against mother nature. 2,100—60 kW Aluminum weather protective enclosure Electrostatically applied textured epoxy paint Fan Diameter(in/mm) 17.7/449.6(25&30 kW) for added durability. 22/558.8(36,45,&60 kW) Quiet, critical grade muffler is mounted in Pusher(25&30 kW) Enclosed critical grade muffler side the unit to prevent injuries. Fan Mode Puller(36,45,&60 kW) Small,compact,attractive Makes for an easy,eye appealing installa- FUEL SYSTEM tion. Fuel Type Natural gas,propane vapor SAE Sound attenuated enclosure ensures quiet Carburetor Down Draft operation. Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard LP Fuel Pressure 5—14 in Water Column/9—26 mm HG NG Fuel Pressure 5—14 in Water Column/9—26 mm HG (All ratings in accordance with BS5514,ISO3046,ISO8528,SAE J1349,and DIN6271) GENERAC® 25 • 30 • 36 • 45 • 60 kW operating data o GENERATOR OUTPUT VOLTAGEAW-60 Hz kW LPG Amp LPG kW Nat.Gas Amp Nat.Gas CB Size(Both) 120/240 V,10,1.0 pf 25 104 25 104 125 RG025 120/208 V,30,0.8 pf 25 87 25 87 100 120/240 V,30,0.8 pf 25 75 25 75 90 120/240 V,10,1.0 pf 30 125 30 125 150 ' RG030 120/208 V,30,0.8 pf 30 104 30 104 125 120/240 V,30,0.8 of 30 90 30 90 100 120/240 V,10,1.0 pf 36 150 36 150 175 RG036 120/208 V,30,0.8 pf 36 125 36 125 150 120/240 V,30,0.8 pf 36 108 36 108 125 277/480 V,30,0.8 pf 36 54 36 54 60 120/240 V,10,1.0 pf 45 188 45 188 200 RG045 120/208 V,30,0.8 pf 45 156 45 156 175 120/240 V,30,0.8 pf 45 135 45 135 150 277/480 V,30,0.8 pf 45 68 45 68 80 120/240 V,10,1.0 pf 60 250 60 250 300 RG060 120/208 V,30,0.8 pf 60 208 60 208 250 120/240 V,30,0.8 pf 60 180 60 180 200 277/480 V,30,0.8 pf 60 90 60 90 100 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @<.4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gal/hr) (1/hr) (0/hr) 120/240 V,10 65 170 Exercise cycle 60 1.7 1 0.7 2.5 24 RG025 120/208 V,30 80 130 25%of rated load 220 6.3 2.9 9.1 88 120/240 V,30 69 112 RG026 50%of rated load 297 8.4 3.3 12.3 119 120/240 V,10 75 180 75%of rated load 362 10.3 4 15 145 RG030 120/208 V,30 96 155 100%of rated load 430 12.2 4.7 17.8 172 120/240 V,30 83 134 Exercise cycle 60 1.7 0.7 2.5 24 120/240 V,10 105 240 25%of rated load 240 6.8 2.6 10 96 RG036 120/208 V,30 44 130 RG030 50%of rated load 320 9.1 3.5 13.3 128 120/240 V,30 38 115 75%of rated load 400 11.4 4.4 16.6 160 277/480 V,30 20 60 100%of rated load 492 14 5.4 20.4 197 120/240 V,10 105 240 Exercise cycle 65 1.8 0.7 2.6 25 RG045 120/208 V,30 44 130 25%of rated load 210 6 2.3 8.6 83 120/240 V,30 38 115 RG036 50%of rated load 380 10.8 4.2 15.7 151 277/480 V,30 20 60 75%of rated load 545 15.5 5.9 22.4 216 120/240 V,10 140 320 100%of rated load 730 20.7 8 30.1 290 RG060 120/208 V,30 70 210 Exercise cycle 65 1.8 0.7 2.6 25 120/240 V,30 61 182 25%of rated load 210 6 2.3 8.6 83 277/480 V,30 30 91 RG045 50%of rated load 380 10.8 4.2 15.7 151 75%of rated load 545 15.5 5.9 22.4 216 100%of rated load 730 20.7 8 30.1 290 Note:Fuel pipe must be sized for full load. Exercise cycle 123 3.5 1.34 5.1 49.3 For Btu content,multiply ft3/hr x 2,520(LP)or ft3/hr x 1,000(NG) 25%of rated load 267 7.6 2.7 10.5 101 For megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) RG060 50%of rated load 483 13.7 5 19 183 Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and 75%of rated load 672 19.1 7 26.5 255 SCAQMD permitting purposes. 100%of rated load 862 24.5 9 33.9 327 STANDBY RATING:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating.Ratings are in accordance with ISO-3046-1.Design and specifications are subject to change without notice. GENERAC® 25 • 30 • 36 • 45 • 60 kW operating data _ ENGINE COOLING 25 kW 30 kW 36 kW 45 kW 60 kW Air flow(inlet air including alternator and combustion air in cfm/cmm) 2,490/70.5 2,490/70.5 2,725/77.2 2,725/77.2 3,280/92.9 System coolant capacity(gal/liters) 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5 Heat rejection to coolant(BTU per hr/MJ per hr) 112,000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9 Maximum operation air temperature on radiator ff/°C) 140/60 Maximum ambient temperature(°F/°C) 122/50 COMBUSTION REQUIREMENTS Flow at rated power(cfm/cmm) 1 62/1.8 1 72/2 1 144/4.1 1 144/4.1 1 180/5.1 SOUND EMISSIONS Sound output in dB(A)at 23 it(7 m)with generator in exercise mode* 59 59 61 61 65 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load* 72 73 73 73 72 *Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output(cfm/cmm) 1 203/5.7 237/6.7 300/8.5 420/11.9 494/14 Exhaust temperature at muffler outlet ff/°C) 1,100/593 1,130/610 1,075/579 1,100/593 1,050/566 ENGINE PARAMETERS Rated Synchronous rpm 3,600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration....................................................................................................................................................3%for every 10°C above 25°C or 1.65%for every 10°F above 77°F Altitude Deration(25,30,36,&45 kW).......................................................................................................................1%for every 100 m above 183 m or 3%for every 1,000 ft above 600 ft Altitude Deration(60 kW)..........................................................................................................................................1%for every 100 m above 915 m or 3%for every 1,000 ft above 3,000 ft CONTROLLER FEATURES Two-Line Plain Text LCD Display............................................................................................................................................................................Simple user interface for ease of operation. Mode Switch: AUTO...............................................................................................................................................................................Automatic Start on Utility failure.7 day exerciser. OFF...........................................................................................................................................................Stops unit.Power is removed.Control and charger still operate. MANUAL...........................................................................................................................Start with starter control,unit stays on.If utility fails,transfer to load takes place. Programmable start delay between 10—30 seconds.......................................................................................................................................................................................Standard 10 sec Engine Start Sequence..............................................................................................................................................................Cyclic cranking:16 sec on,7 rest(90 sec maximum duration) EngineWarm-up.............................................................................................................................................................................................................................................................5 sec EngineCool-Down..........................................................................................................................................................................................................................................................1 min Starter Lock-out.........................................................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger................................................................................................................................................................................................................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection........................................................................................................................................................................Standard AutomaticLow Oil Pressure Shutdown........................................................................................................................................................................................................................Standard OverspeedShutdown.......................................................................................................................................................................................................................................Standard,72 Hz HighTemperature Shutdown..................................................................................................................................................................................................................................... Standard OvercrankProtection..................................................................................................................................................................................................................................................Standard SafetyFused..............................................................................................................................................................................................................................................................Standard Failureto Transfer Protection......................................................................................................................................................................................................................................Standard LowBattery Protection................................................................................................................................................................................................................................................Standard 50 Event Run Log.......................................................................................................................................................................................................................................................Standard FutureSet Capable Exerciser..................................................................................................................................................................................................................................... Standard IncorrectWiring Protection........................................................................................................................................................................................................................................ Standard InternalFault Protection..............................................................................................................................................................................................................................................Standard CommonExternal Fault Capability..............................................................................................................................................................................................................................Standard GovernorFailure Protection....................................................................................................................................................................................................................................... Standard REMOTE MONITORING • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC° 25 • 30 • 36 945 • 60 kW available accessories o Model # Product Description — Generac's Mobile Link allows you to check the status of your generator from anywhere G0071690 Mobile Link°4G LTE Cel- that you have access to an Internet connection from a PC or with any smart device.You lular Accessory will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required.Available in the U.S. only. If the temperature regularly falls below 32°F(0°C),install a cold weather kit to maintain G005630-0-1 -36,45,,&60 kW ' G00 -25&3 Cold Weather Kit optimal battery temperature.Kit consists of battery warmer with thermostat built into the 630 6 wrap. G006174-0-25&30 kW Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32°F(0°C)for extended pe- G00561 6-0-36,45,&60 kW riods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged,it is important to touch-up the paint G005703-0-Bisque Paint Kit to protect from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006176-0-25&30 kW Scheduled The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to per- G006172-0-36&45 kW Maintenance Kit form complete maintenance on Generac liquid-cooled generators. G006171-0-60 kW G007000-0(50 Amps) Smart Management Smart Management Modules (SMM) optimize the performance of a standby generator. G007006-0(100 Amps) Module They manage large electrical loads upon startup and load shed to aid in recovery when overloaded. In many cases, SMMs can reduce the overall size and cost of the system. E-Stop resettable switch E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emer- G006510-0 for commercial installs to NEC2020 gency. The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected G007005-0 Wi-Fi LP Fuel Level LP fuel tank.Monitoring the LP tank's fuel level is an important step in making sure your Monitor generator is ready to run during an unexpected power failure.Status alerts are available through a free application to notify when your LP tank is in need of a refill. An ultra-concentrated anti-corrosive cleaning solution engineered to reach the smallest A0000018981 Ultrasonic Cleaner Solution cavities to clean the toughest contaminants. This water based formula is non-toxic, biodegradable,and safe for both metal and plastic surfaces and is superior in rinsability. A0000019001 All Surface Protectant All Surface Protectant for vinyl, rubber, and plastics creates a barrier that seals &protects surfaces from water and UV rays while renewing the look of the surface. GENERACO 25 & 30 kW installation layout Drawing#OK8420-B (1 of 2) o O W U A � O�UZQ w Ol �n VO v wp g ZW v aw�w o o� w o W W W ono NWZ Zff 3 VOz- O �¢IZw�0 m ¢���0 \ m�N o�❑S3 Pmm �o�w .0N �000wzNhz�i a rcS oo x _zw OH,o wo 'wWo w?zw a LLizorc-.0 NO9 -. <� `-"� w o woQa oqu a°�owo m�zz �� o° �❑ - > u-mti❑ z�c°iW zgm¢z>wzw�iz a u55z w WH WZa> OSOam6R�S.�W�tOi1-IS — o W;W 3 rcoN,i��wCYo�wr❑❑Qa 3w x °❑¢� �o�w3zWzo�,a�m�oyzaw�❑m o mONN�oaz3yo�❑o�°oyWo� s ❑z��z�i�wu�o�mO❑x � No3wzm°a oo-❑wow 0-OjZ❑0 ZmwZWaOy O�fL WQ w5�y�°�z0waz°°z��o�aoww�m�ww uwo m,w.aa��rcwwoz$>WzW'W, gIz O m�cLL°W<�wmwzw� z�3 ❑ �xwo w zLLzzo za�w aoo°c�oomoom;zx°❑� Z�z mu>>mz�um�?� oogNWcA,!0 �z WoI �wm owmw600Q0W2❑ zFao� W w W Qamur�»>K a o w zw�oa�z"��yx�>I �WIZm`~�w,�a W mOoo aow°wW�wowo°xworo so > Z �Ka Za Q�MmaK2SZWn�nmrmrn?�t2QtiK �� rcm n e ¢Wm TT W❑O w° aWF ma0 00 ¢<U Kwzz O Z U W m0 W mK O z �n QOW2� pW m WJUU�� Uaw rZ fm¢�wo O�Ww'° 4Ww Kw 7mi000w ¢am m K°UN S O zY <Mm$ 2 - e3 o OoOOOO�oo > Ozm a❑O O O O O O w❑O .x x x x x x z x i 3 'ioc�0000wxo a z i.:'.:i a m w rc rc z z rc d m w d Q r a W ❑ w�w W a F i� z__ w N W i w o W w W OUz m o� W 3 oWJ m m m F. �z Waw 3-Z w¢a —2. mu° a rc 0 0 0 ¢w w m v m°o ¢ m wag "❑� K Q K�� m >h; 7a a w OOz OW y N Q Q z ZWW Z2 Wzw w w zz$z zz T WUa Y Yfl Y Y F W N N m >N vOZ o ZS �ZW COm U 2 a� Z. $ 3 G>l FZ x< > w u�WW ° °¢❑n a0F �o� WW WZo LLIU �❑o yW ❑ o01 ma ���nlly ix =o� a w2W °w� V xa Xzo " 0 &0-> 8� a� k O 2<OF woa O m =0 Qa y W W� �a GENERAC® 25 & 30 kW installation layout Drawing#OK8420-B (2 of 2) W wo mU ¢a O m vi(7 zz OZ Fw w0 zz z 0, W V W Q Z pto >K � W 020 aw 0 3 ❑N F W z� ¢V Nm W 7Z mZ S¢ ar o �z �s $ Wz ¢�E aW W D r� N a0 F F� � Z_ « V oa 97 u&j a y N� a O� y w w zN > 1. 0 -H N lq W W mZ � y Z 0 Oq H 0 N m� m z XZ NIX a GENERAC® 0 36 & 45 kW installation layout Drawing #OK8636-B (1 of 2) v LL% W K °o 000�� r KFWW wm ° U>ZO 0000z0 Q w Z 0— LL OaOo�OzZFZKzK�UFW-W❑uSa¢ wOoUz~zz°zaW O���OW�-3QR'azo¢iU�Zro3OLLKKK C7 wO(wuKl wNN�a W��am�o��O Oz "aY aCn zW- O KOK Z0 aQ QO WOc �Q 0 - ° gw � ON =t� aZz ZW °° $° W Vc � wOxUz rO'D<3 p w w z SZz0o Q LLN W9NWO 3KyWmwa ZwwxLLKKQNQ _ O(l mOxUm S O w0¢¢ O�WLL aOrxzOzz a a wai°z ?�vw z¢Ziw9LLz Kv°z w aOZQ Kw¢> oxo¢mQ�°,-.w�NgaQw W J m n Q O W O m U K J S O Q LL W F Z W LL'W W N p�a�a KO��OZkZw�cW'l¢v~iwu3¢OZV 0 �z O U'OgLL 00�mm�OQa3NK°°°Ozv~iwLL¢ is m z��z FW°OOFm_ Qz°O z ,n 'n� W W�p�zpU W. p w¢ON�NpO�w¢ao y� W g�v�r°Uz°�aiz�z��°KKO W'��m oxK w� W ° g¢zxM��O�¢QOw0>wLLZmQw°NKzQ N� OZ C7z �HWf¢Q�F WWUZU ZO FUK��QLLLL OW UOyQF O fn U C7 LL 0 Z¢ K K W Z W W Z 3O JO°LL Z J F z V ¢U W x— UZ-zZz¢LLWWQU'OC7 U'U'O mK Km z OQw KyUU�+� W-it a_�SLL¢U¢LLLLrw ¢3�0-'0 za, w�U Ow I K W�Uz°WUm�°�WJ00 UClOOKFQOFK WKO �m¢YW� MUW,5mQ0251 lggQ 7Zzz C~ALL KWZ i2 W'So ff ^ °W3wQ WW.Ws >uiOUmFr 2M' a>w rww a 3m 8a w 2WOmom zwcwi�N.w3 zr�LL�woiwW�XO �C)0 �¢am�W F OaQOWUWw_z0W0 OW Om°w OOX g wazaWOmaKxx OmwK�°gS z w z �K�i¢¢woi v~ 06xar. 6mo¢'K - x Emma _aY e -- - a u O. =�ppwwpwwW��w8 =W YZ w x-- - z Z a p W K C �� <w Hm 0 Jzd�S os�W ono wimzJ Ewa "waz 3�w,- U W. z W K m°3 U' o+ Puri w�w�ww�>z=3KN >�wo �zYn�v�O'i °O U—I'M �Wrc�u Rr'OQ0 00mw 4Wr i� W. J§ o "= F�F 00Z w~Zz Aga tx7� rcLL° orcaw o mo>W y >yF "Ww �J �+°p°°a� j X,, 2 O Z LL Y W O o w W0¢ � wr $ KLLa mZ o w °N 00 Y Y 0 ZW z O9 W N f W W n �LLO Z ww ^ MOz <tA aw W z x z u °' Km Wv o Q� U a W U w� W >� ONLL > p U W K LL woo p Z LL N WOK FW K0 upiN F U>Z m Fa w ¢am z w w WAN \� ZW n 00 S f V V W x 7 Q m G LLf0 20 K Wz �K �Ww ¢Q y m OJ K X W xS Z 4O4 W K WWW Ox W ¢m 0 �O G E N E RAC 36 & 45 kW installation layout e Dm«m*OA6$B (of% - $j §$ !§ / /U \\ )( LU (O 2 ([ ' ) ]a \LU e ! ,/ e0 > §) �f / ) X LU Z ' �\ \§ 2/ °^ kLU CO \k m/§ -a,< § CL : ( D� ƒ 21§$ , ! 0>, 2 iJ( co Iz m §[ E LU s s F) [ \ : « § ! 2 k CO :q \OR GENERAC® 0 60 kW installation layout Drawing #OOL2090-B (1 of 2) U Q LL W a J 0LLp0 yya z(1) a 000a§ �NF 0 W O Z �W W W ^Z H z U aroN`�¢"D���7 ZQLLaLLtA mrQoa �aQNQWoO}N�U U~S Up0QOC7 OLLQ>K-LL OZLLUN�w zF�mg— �OUx mO��~N~zc�U7 W LLmN1`LLLL~O Z J a- ofW OW W UZ 5Z Zz W VWWOO 0000z� W LWU W 0 w a Ux z !zz� wL wU w1X W f a O�O�O _Waa ¢ W wWoZpwO O z}a 0~0'w� w° z g-0 6W z aan O.UUZ r0aO O W n _(o60 FZw 2,WZ.QUJw3 mw Wa wn0 0zCO0 0 W� O> xWw NWWQ az Qaaa rOi 6=0020Ja0 O�NQQmPxzOzz 3 3w_>w�N _= z LLLLwviz za�W z¢z}w°rizU<z o W yNWN WzKO 70 j 0 NO� f ulaOa�zWZO�WO��ZQW�mW N O 7a a0E-- WFOQW WLL�QOzU Z 7Z 0 0 z E tz Z N 7 W U O 2 O m O 0 a x¢ m O Z a O O N In W<ZZ p�pZZOUxxZNwzUZOU�NoOaw¢z~ w Z Q a 0 Q O a(n O W Q Z 0 Z}Q}QQ 0(n a F LL¢m W Q W WJFy mUUZ50., /.O ZFK�WOWLLI�~OWZ U.) 0 H W ¢Q J O a W W OU W OU>z O z r N z g Q lJi LL a W U,z O NU(�LL°zQ�aaw zw9WzOOOLLZMM,� O Uz0(nax w zLLzz�¢Uwwa000000WmQ 2+�ON�O OW ¢OW=~> a W LL U W U LL LL J M S F O Q LL LL F U m D O H O N K z 0 a U U> 2 Z=—J O W fn W m O J J a Z Z Z J aQ r N LL Z LL w W J U}p H (7 n>p]Z Q w¢¢WO-U)WW>D 0>WFOFU�FFQLLwQ°w Wa0 O�Jaw0 wy W Z W OmJF z W U�NO W 3izF a lW,W N W W~XO XWZ Q>W fn tnZFU W Z(7 ry LL J O LL Q O W U W W_ O W O U WON 7 W O U W 2 W O W O(A Q Q O W Y F W Q zLLFU(q¢LL'xxZO W.w a� m2 Z W O .a Q¢tp F a (AOQ�a aUN QLLaO J(A z fV M O N fG IA W 6 0 Y CNN� F > wZd= w �W� O^O > WFO S S O O 0 0 0 O O W W O O J �(j� W �1Y a F N F N N N N O K O N ~ J Q J >W11 - N W L W LO W W Z W W W F W W K �W Z¢ O W a J J J y W W J Q F O> a J N k 2 wQ ag OOJ W �O x1m N N wo°ma W z� wLL �maZ 3wNO-_ I N w o a��>�J >>� w 0�o 3 z F O F 2 Q _ -LL W K Z LL > N >J J U' w a za>LLWa mmW az OU U, O°wU o6Jx o 0 o z Y W z k a woz U zz W o ooWr e5aaa UOF W0—w WM y� o a s o W m o> z�N >(n¢a Yw >w m 0 p a z Q U N m a K W J U Z W W~ O x Z �. r K O Q �y LLaa W UQ W m Z Z J OJF N o WOQ a¢�a W OLL wm aLLLL ~w rp �N zw U zJ O� i } U 3F_ W Wi W Yp Q>Q Za rn 0 J Z W. Z= ry LL W H co m LL m Qm Q wW o WOE mF o J Z ULLI Wa U 2r W OQQ > > LL W 0OQ O Ex LL a H n H W O W N J O O 7 ja1 Q Q p }j x W W o v a r w(JN wmC7o 0=x Q°>Z 0 �a amm r(p m Q W=7 ^Q.... (O tD W LL HN LLQ z �S F ET (Wiiw �a Q¢ m� ¢d0 WU, Q~ a WW, 0= a W m 0 Q s G E N E RAC 60 M installation layout e Dm«m *OLO$B (2 m2 - § @O \| §G �a §00 0 (\ \ 0\ 2§ 0 <� § y\(\ \ ! .Mx 14 y, a! ® §( ( !q m\ = / }¥ � § / ;j §0x /\ G E N E RAC° Systems,GeearG Power 2. • k5W 9 90HWY.5n Waukesha,m 531m • geearcgm in oo G_r Power Systems,Ic All rights»m+ All specifications are subject E change knt notice.Bulletin oOEoamvNAmo PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated 4 �t R CITY OF ARLINGTON BUILDING DEPARTMENT )A - PR(0VED DATE 3 BY4�� O CHANGES AUTHORIZED UNLESS APPROi/ED BY THE BUILDING INSPECTOR I hereby certify that I am the❑Owner;❑Applicant tractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. Signature Print Name Date REvz.zozo SAVE PRINT Page 3of3 GENERAC° Protector® PROTECTOR° SERIES Series Standby Generators Liquid-Cooled Gaseous Engine Now- INCLUDES: Standby Power Rating Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz • Two-Line LCD Multilingual Digital Evolution— Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Controller(English/Spanish/French/Portuguese) Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz with external viewing window for easy indication of Model RG045 (Aluminum - Bisque) -45 kW 60 Hz generator status and breaker position. Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz • Capability to be installed within 18 in (457mm) of a building* -- - _ • True Power M Electrical Technology _ • Isochronous Electronic Governor • Sound Attenuated Enclosure �— • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses E • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty u^ke E1� us • UL 2200 Listed uM° *Only if located away from doors, Note: 25-45 kW units are field convertible Y Y between natural gas or liquid propane.60 kW windows,fresh air intakes,and unless Meets EPA Emission Regulations otherwise directed b local codes. 25,30,&45 kW meet CA/MA emissions compliant units are built per fuel requirement and are not y convertible. Applicable for 25 kW and 30 kW units only. 36&60 kW not for sale in CA/MA FEATURES O INNOVATIVE DESIGN& PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it REGULATION. This state-of-the-art power maximizing regulation doesn't stop there. Total commitment to component testing, reliability system is standard on all Generac models. It provides optimized FAST testing,environmental testing,destruction and life testing,plus testing to RESPONSE to changing load conditions and MAXIMUM MOTOR applicable CSA, NEMA, EGSA, and other standards, allows you to STARTING CAPABILITY by electronically torque-matching the surge choose GENERAC POWER SYSTEMS with the confidence that these loads to the engine.Digital voltage regulation at±1 systems will provide superior performance. O TEST CRITERIA: O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive ✓PROTOTYPE TESTED ✓NEMA MG1-22 EVALUATION dealer network provides parts and service know-how for the entire unit, ✓SYSTEM TORSIONAL TESTED ✓MOTOR STARTING ABILITY from the engine to the smallest electronic component. O MOBILE LINO'CONNECTIVITY:FREE with all RG generators, Mobile O GENERAC TRANSFER SWITCHES. Long life and reliability are Link Wi-Fi allows users to monitor generator status from anywhere in the synonymous with GENERAC POWER SYSTEMS. One reason for this world using a smartphone, tablet,or PC.Easily access information such confidence is the GENERAC product line is offered with its own transfer as the current operating status and maintenance alerts. Users can systems and controls for total system compatibility. connect an account to an authorized service dealer for fast,friendly,and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC 4gj s7-2r6 GENERACm 25 • 30 • 36 • 45 • 60 kW application & engineering data _ GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS:25&30 kW Type Synchronous Make Generac Rotor Insulation Class H Model In-line Stator Insulation Class H Cylinders 4 Telephone Interference Factor(TIF) <50 Displacement(Liters) 1.5 ' Alternator Output Leads 1-Phase 4 wire Bore(in/mm) 3.05/77.4 Alternator Output Leads 3-Phase 6 wire Stroke(in/mm) 3.13/79.5 Bearings Sealed Ball Uompression Hatio 11.1 Coupling Flexible Disc Intake Air System Naturally Aspirated Excitation System Direct Litter Type Hydraulic VOLTAGE REGULATION ENGINE SPECIFICATIONS:36,45, &60 kW Type Electronic Make Generac Sensing Single Phase Model In-line Regulation ±1% Cylinders 4 GOVERNOR SPECIFICATIONS Displacement(Liters) 2.4 Type Electronic Bore(in/mm) 3.41/86.5 Frequency Regulation Isochronous Stroke(In/mm) 3.94/100 Steady State Regulation ±0.25% Compression Ratio 9.5:1 Intake Air System Naturally Aspirated(36&45 kW)or ELECTRICAL SYSTEM Turbocharged/Aftercooled(60 kW) Battery Charge Alternator 12 Volt 15 Amp—25&30 kW Lifter Type Hydraulic 12 Volt 30 Amp—36,45,&60 kW Static Battery Charger 2 Amp ENGINE LUBRICATION SYSTEM Recommended Battery(battery not included) Group 26,525 CCA Oil Pump Type Gear System Voltage 12 Volts Oil Filter Type Full flow spin-on cartridge Crankcase Capacity(qVI) 4/3.8-25,30,36,&45 kW GENERATOR FEATURES 5.25/4.96—60 kW Revolving field heavy duty generator ENGINE COOLING SYSTEM Directly connected to the engine Operating temperature rise 120°C above a 40°C ambient Type Closed Class H insulation is NEMA rated Water Pump Belt driven All models fully protolyped tested 2,484-25&30 kW ENCLOSURE FEATURES Fan Speed(rpm) 1.865-35&45 kW Ensures protection against mother nature. 2,100—60 kW Aluminum weather protective enclosure Electrostatically applied textured epoxy paint Fan Diameter(in/mm) 17.7/449.6(25&30 kW) for added durability. 22/558.8(36.45.&60 kW) Enclosed critical grade muffler Quiet, critical grade muffler is mounted in- Fan Mode Pusher(25&30 kW) side the unit to prevent injuries. Puller(36.45.&60 kW) Small,compact,attractive Makes for an easy,eye appealing installa- FUEL SYSTEM tion. SAE Sound attenuated enclosure ensures quiet Fuel Type Natural gas,propane vapor operation. Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard LP Fuel Pressure 5—14 in Water Column/9—26 mm HG NG Fuel Pressure 5—14 in Water Column/9—26 mm HG (All ratings in accordance with BS5514,IS03046,IS08528,SAE J1349,and DIN6271) GENERAC' - A 25 • 30 • 36 • 45 • 60 kW operating data o GENERATOR OUTPUT VOLTAGEAW-60 Hz kW LPG Amp LPG kW Nat.Gas Amp Nat.Gas CB Size(Both) 120/240 V,10.1.0 pf 25 104 25 104 125 RG025 120/208 V,30,0.8 pf 25 87 25 87 100 120/240 V,30.0.8 pf 25 75 25 75 90 120/240 V.10.1.0 pf 30 125 30 125 150 ' RG030 120/208 V,30,0.8 pf 30 104 30 104 125 120/240 V,30,0.8 pf 30 90 30 90 100 120/240 V.10.1.0 pf 36 150 36 150 175 120/208 V,30,0.8 pf 36 125 36 125 150 RG036 120/240 V,30,0.8 pf 36 108 36 108 125 277/480 V,30,0.8 pf 36 54 36 54 60 120/240 V,10.1.0 pf 45 188 45 188 200 120/208 V.30,0.8 of 45 156 45 156 175 RG045 120/240 V,30,0.8 pf 45 135 45 135 150 277/480 V,30.0,8 pf 45 68 45 68 80 120/240 V.10,1.0 pf 60 250 60 250 300 120/208 V.30,0.8 pf 60 208 60 208 250 RGO60 120/240 V,30,0.8 pf 60 180 60 180 200 277/480 V.30,0.8 pf 60 90 60 90 100 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @<.4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gal/hr) (1/hr) (fta/hr) 120/240 V,10 65 170 Exercise cycle 60 1.7 0.7 2.5 24 RG025 120/208 V,30 80 130 25%of rated load 220 6.3 2.9 9.1 88 120/240 V,30 69 112 RG026 50%of rated load 297 8.4 3.3 12.3 119 120/240 V,10 75 180 75%of rated load 362 10.3 4 15 145 RG030 1201208 V,30 96 155 100%of rated load 430 12.2 4.7 17.8 172 120/240 V,30 83 134 Exercise cycle 60 1.7 0.7 2.5 24 1201240 V,10 105 240 25%of rated load 240 6.8 2.6 10 96 120/208 V,30 44 130 RG030 50%of rated load 320 9.1 3.5 13.3 128 RG036 120/240 V,30 38 115 75%of rated load 400 11.4 4.4 16.6 I 160 277/480 V,30 20 60 100%of rated load 492 14 5.4 20.4 197 120/240 V,10 105 240 Exercise cycle 65 1.8 0.7 2.6 25 120/208 V.30 44 130 25%of rated load 210 6 2.3 8.6 83 R1045 120/240 V.30 38 115 RG036 50%of rated load 380 10.8 4.2 15.7 151 277/480 V,30 20 60 75°%of rated load 545 15.5 5.9 22.4 216 120/240 V,10 140 320 100°%of rated load 730 20.7 8 30.1 290 RGO60 120/208 V,30 70 210 Exercise cycle 65 1.8 0.7 2.6 25 120/240 V,30 61 182 25%of rated load 210 6 2.3 8.6 83 277/480 V,30 30 titj RG045 50°%of rated load 380 10.8 4.2 15.7 151 75%of rated load 545 15.5 5.9 22.4 216 100%of rated load 730 20.7 8 30.1 290 Note:Fuel pipe must he sized for full load. Exercise cycle 123 3.5 1.34 5.1 49.3 For Btu content,multiply ft3/hr x 2.520(LP)or ft3/hr x 1,000(NG) 25%of rated load 267 7.6 2.7 10.5 101 For megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) RGO60 50%of rated load 483 13.7 5 19 183 Refer to "Emissions Data Sheets" for maximum luel flow for EPA and 75%of rated load 672 19.1 7 26.5 255 SCAOMD permitting purposes. 100%of rated load 862 24.5 9 33.9 327 STANDBY RATING:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating.Ratings are in accordance with ISO-3046-1.Design and specifications are subject to change without notice. GENERAC® 25 • 30 • 36 • 45 o 60 kW operating data ENGINE COOLING 25 kW 30 kW 36 kW 45 kW 60 kW Air flow(inlet air including alternator and combustion air in cfm/cmm) 2,490/70.5 2,490/70.5 2,725/77.2 2,725/77.2 3,280/92.9 System coolant capacity(gal/liters) 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5 Heat rejection to coolant(BTU per hr/MJ per hr) 112.000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9 Maximum operation air temperature on radiator(°F/°C) 140/60 Maximum ambient temperature(°F/°C) 122/50 COMBUSTION REQUIREMENTS Flow at rated power(cfm/cmm) 62/1.8 72/2 144/4.1 144/4.1 180/5.1 SOUND EMISSIONS Sound output in dB(A)at 23 it(7 m)with generator in exercise mode` 59 59 61 61 65 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load' 72 73 73 73 72 'Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flaw at rated uulpul(cfm/cmm) 203/5.7 237/6.7 300/8.5 420/11.9 494/14 Exhaust temperature at muffler outlet(°F/°C) 1,100/593 1,130/610 1,075/579 1,100/593 1 1.050/566 ENGINE PARAMETERS Rated Synchronous rpm 3,600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration....................................................................................................................................................3%for every 10°C above 25°C or 1.65%for every 10°F above 77°F Altitude Deraticn(25,30.36,&45 kW).......................................................................................................................1%for every 100 m above 183 m or 3%for every 1,0001t above 600 It Altitude Deration(60 kW)..........................................................................................................................................1%for every 100 m above 915 m or 3%for every 1,000 It above 3,000 It CONTROLLER FEATURES Two-Line Plain Text LCD Display........................................................................................::.....................,..........................................................Simple user interface for ease of operation. Mode Switch: AUTO..............................................................................................................................,...............................................Automatic Start on Utility failure.7 day exerciser. OFF...................................................................................................................................... ........ *........Stops unit.Power is removed.Control and charger still operate. MANUAL...........................................................................................................................Start with starter control,unit stays on.If utility fails,transfer to load takes place. Programmablestart delay between 10—30 seconds.......................................................................................................................................................................................Standard 10 sec Engine Start Sequence........................................................................................................................::.................................... 7 rest(90 sec Cyclic cranking: sec on, maximum duration) EngineWarm-up......................................................................................................................:::....................................................................................................................................5 sec EngineCool-Down.....................................................................................................................,............................................................................... ........ .............................................1 min Starter Lock-out.........................................................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger....................................................................................................................,........................................................................»................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection............................................ ........................... .................................................................................................Standard Automatic Low Oil Pressure Shutdown............................................................................... ..................................... ............ ............. ...............,........................... ........... .....................Standard OverspeedShutdown......................,........................................................................................................................ ............ ............. ........................................ .......................Standard,72 Hz HighTemperature Shutdown.................................................................................................................................................:...................................................................................Standard OvercrankProtection.................................................................................................................................................................................................................................................Standard SafetyFused..............................................................................................................................................................................................................................................................Standard Failureto Transfer Protection....................................................................................................................................................................................................................................Standard LowBattery Protection................................................................................................................................................................................................................................................Standard 50 Event Run Log.....................................................................................................................................................................................................................................................Standard FutureSet Capable Exerciser.....................................................................................................................................................................................................................................Standard IncorrectWiring Protection.........................................................................................................................:..............................................................................................................Standard InternalFault Protection.................................................................................................................«. .......... ...... .................... ......................................................................................Standard CommonExternal Fault Capability.............................................................................................................................................................................................:................................Standard GovernorFailure Protection....................................................................................................................................................................................................................................... Standard REMOTE MONITORING • Ability to view generator status Monitor generator with a smatp one,tab el,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generators compete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specilic model generator when scheduled maintenance is due. • Monthly report with previous month's activity Delar monthly reports provide historical generator information. ♦ Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. 9 lWeather information Provides detailed local ambient weather conditions for generator location. GENERAC® 25 • 30 • 36 •45 • 60 kW available accessories o Model # Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere G0071690 Mobile Link°4G LTE Cel- that you have access to an Internet connection from a PC or with any smart device.You lular Accessory will even be notified when a change in the generator's status occurs via e-mail or text message.Note:Harness Adapter Kit required.Available in the U.S.only. G006175-0-25&30 kW If the temperature regularly falls below 32°F(0°C),install a cold weather kitto maintain G005630-1 -36,45,&60 kW Cold Weather Kit optimal battery temperature.Kit consists of battery warmer with thermostat built into the wrap. G006174-0-25&30 kW Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32°F(0°C)for extended pe- G00561 6-0-36,45,&60 kW nods of time.For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged,it is important to touch-up the paint G005703-0-Bisque Paint Kit to protect from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006176-0-25&30 kW Scheduled The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to per- G006172-0-36&45 kW Maintenance Kit form complete maintenance on Generac liquid-cooled generators. G006171-0-60 kW G007000-0(50 Amps) Smart Management Smart Management Modules (SMM)optimize the performance of a standby generator. G007006-0(100 Amps) Module They manage large electrical loads upon startup and load shed to aid in recovery when overloaded.In many cases,SMMs can reduce the overall size and cost of the system. E-Stop resettable switch E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emer- G006510-0 for commercial installs to gency. NEC2020 The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected G007005-0 Wi-Fi LP Fuel Level LP fuel tank.Monitoring the LP tank's fuel level is an important step in making sure your Monitor generator is ready to run during an unexpected power failure.Status alerts are available through a free application to notify when your LP tank is in need of a refill. An ultra-concentrated anti-corrosive cleaning solution engineered to reach the smallest A0000018981 Ultrasonic Cleaner Solution cavities to clean the toughest contaminants. This water based formula is non-toxic, biodegradable,and safe for both metal and plastic surfaces and is superior in rinsability. A0000019001 All Surface Protectant All Surface Protectant for vinyl, rubber, and plastics creates a barrier that seals &protects surfaces from water and UV rays while renewing the look of the surface. GENERAC® 25 & 30 kW installation layout Drawing#OK8420-B (1 of 2) w s=z= o � m w3= ggi<o:wa w=o s aa�;o LL�oJ oN �Qa=woy aoo° = ppFywoWZZw VI�W Fw Q a �- / N 3FWQ aiNw a'�3'z°Eiu3r�n 1a=-ww fdg UNAA o �u ¢ - worl ?2.18Oy 3$ s S oia zw a i�iam�rc� Wes_ w�a> o°o�FaW o ao aeQ�� g°�¢�'iwz�f w°�oaa-w-lI�n3w 0581.�U mo mr'n o�m ;yrc��o�ooyrco� .. a ozE�zm�Uu�O� °o �E o3LLza°a . waz Nz 0Qzz z m wo8ia°o- '�'o°¢m w,z„° V E. ¢o-'�° Fz w.z-a°up ;�owwLL� ��� o muoLL w¢ra� §01.-..- 8 w?uzz�acUJw FUF ooFNwZOOf Oyfi wUw °�3wcaiaawww'� �wou�wFN�uz 1` w �rc�aam�ya i�wo wm°'�wom Ew°o'z � i w ¢ - 1 - � Q m O° y �2P a W H pw ayUUi• a it iE �R � gg gggggggg d N c�RRRR 15 at MR g� his < LL � 59 Wbo ow t;r.Io z �ieo � 3 qX�S Is m a�o oay � 99a�F c�25 =w yyyy goo a°woff o \-I m �c a�= z 4c �5 GENERACO 25 & 30 kW installation layout Drawing#OK8420-B (2 of 2) Wp OU Dm _ u� `I p I m ?z oz Ua wp zz 00 UU a� ~Z 0 V OU �W O Z pogo z. ¢U m y ¢ 2p —V V Z I¢ K O� Q J K2 7 QyQ JW N m , OU Z� . U a nJ rrc ui¢ rc 3 jw > FU O N m5 0 �z r J O N r 0 m3 X z r J n E v >G F GENERAC' 36 & 45 kW installation layout Drawing#OK8636-B (1 of 2) V S� o0 o �W�oaw zz 11 s�oSo w z o U F-Q Z ZW z0 N LL .Wi W �C7QWW (wj OZ°iWN Vl W W Q J �aw¢w Nwz�� QmQ z'xg�3Nzo ° Ewa ° _ SW W 02ort- jWy w w¢m�F o ZOwp �=Ez at-C7 w wOQw� n C� 3��za �wz m zzzJw nmOorn ON p�UJ w0 < ¢ZO JZ r'> =•O ¢< ❑w UUF mp x xOpVW _- > «°go ° z z�w ¢ w�NwOW(7w Wc�xwz Oa,JFazU p¢mm= W FWg< OF<Wo ¢>mwyK19 SWmo3 N3~W❑ EJQz O�QQZ z���i lJll V°1xQ(Z/IW NOw K ¢ UWKQU�[7 C7 �JS 41 2 p wOQ¢ O�wa ¢(7Fxzp z_z ��'¢0 V d UWO 20 z �W¢> o2z¢mz ¢'��az o �yy N Yzi W OV JY.�y�O�UQppQ�-y W J m W O N U m 2 J<w W Z W opO�z oao3yaio�o�ymQ¢ Na m w 00~pw�wV OFmrp¢xQ��3 zoo w Z g�N¢p¢mcx7¢wazz°-Z<O¢N�oiKaa06 wm W aW $— �FW�QQU��WwU°w0>QZpzuFJNWJ�Qwd yW pop�/i K= OW Vf7LLVz¢tix wzwKWZ3 ❑W SLL `2� (n¢I ¢wLLc�wOaLLw=a¢�¢LLLL��m¢3�ONE O za- cxi3w Um�J�J�ooSzzz��r-°r�nW wmo Q�w� i Owywmp p�ti wz ww O u E¢3wc¢i LLi >�,ouxlr¢ww¢Jw >w w¢z 3m ;A W zxofn'HZ,wwo NSJ?i Z�wwJNf~/IWzti 20 °U U1 -JNQQOW Z� ..��� p a¢ow Oww�WOwoVwOWJ wows ¢amwrn gg I �¢<a¢v�imv�¢mFxz v°immmmJmaio w o w c�Zm � $ _ o ASS,> Ny�sz� .1 x�YK � _�[ w3�� DO�zw xo�9��^ im°� c77 wa waz ya wj � ypyp- z,I. W�mo 31:243�A M. ��m woz u Q�xl o rwwwQ wttm 0 Q1w LLaF [�zLL "�2�w ¢� �o 4�w W w Q �pa ¢ ¢ Z Z? z ti W Z.j z �m .w W oW °W °y Ww WW �oz zI < Y O y m=W a Z zx� p,ma ` H z ao A W m U a _ _ U _ � W, �i 1 Uw- > U p N N z o N KO >jOQF OaQ ¢o0 kw ¢°�� r m ¢a w p <<W z w OixW o a $r s� QUO �nm lf3 o-`- o � m ¢< a J o w 2 W x . 4 w� RK W OS w <V N V Q❑ G E N E RAC' 36 & 45 kW installation layout Drawing*OG&6B /y% - }§ u\ \ \ B§ #� \\ j§ �� • . )k §) § C3 to) ƒK �6 2§ 7 ` �2 §ƒ § � \\ ' ■\ °� k� (\ @7/§ _& \ § ~ a GAG § k ! � e « \\ { / \ / �� ° � ( §CD / §� j /0 f � 3k GENERAC' 60 kW installation layout Drawing#OOL2090-B (1 of 2) 7� wW 0LLvmo ^a OZ O Z O --WW Oa� 4r. 9O z ¢a 7 W w I m O W W U z a W LLl Z 2 0 LL ' 1 2WQWW (w9 O2vi fn W y m 0000 .. �a W W W U�W W' O yFm-Q m LLH�W U NWZU a, QW Z""3NZ OJ fWj NwQ Z X W _= W O O Q y LL O W N w \ 3 Z°w} 7 O H W W WZ. d W H .n�..W�p Val OW OvUU W 0 ¢ Qzw 0�2 ^a W OW2 W Q O W UU� W O = Ho W mZ > �FW0J �U ¢�3�aUWm ¢�UKW N� ww MM. ma wJNw�wZv w�NW= Wo .-xWa3 p-W'r .0 m -=W zm OJm� O>LLOO W W LL Qm R'H— !�❑ mm ¢ _ w�=oN Q�mJ <ONmUma<U x�LL20 , WW m❑LLB W U W nm W W mpx-m - O W Q7mF� O�Wa Q0HUwpZZ e� WOO — U wao_z_a ?Wow ?=3¢mz riz a�S¢Z z W f=m W(<- W Z,O �U��F-Q W 041Y�m0 J WJ m QWFOpH�HjxmO�zUOKm�jpw2�iWF-QWO¢�WFZ3W¢�O WZyU �. mU imw zZ ¢~/n pp0p2a Q 6 WQZo�O�t~i1WLL¢ z O O V O W U 2 x Z m w z U z p U y W O W W Q Z OF W o—O z❑ wg�m�°UZO¢mz�z��O�o o`J`<WO�z mo ��w�Q¢����W O wo>wO z m<w x�W�a W mW W OU Z U WLL UO Z U F W Q U Z W K U Z O JO O W Z U 7~ U U 2 W Z W—LL Z Z J d W J 2 a Q O Q LL LL O W m<O M O m 2 p JO W ¢UU W=~ W U p U J O J U m F O J J O U W D O r O F K z v U U mzm>mzoW—wm aJp gzzz�Wo ga FmLL oaw �c� w �W3W<<WaN»�W>Wo�V<O.Qxw way m¢�w~ �WOm�HZW CW)�N=�3zk�LLUmu~iwz�=O Wz wwW<Z 3m 39� F ?W�oa¢OwUww�wpw OUWOwm,w =o Ow �y¢¢Ow zY , W<z"OWOWxx ZJ UmWW�m� OX2 Um QdmJm z �W .Q¢m� ~ m�W�m7aSmo¢^W = J �NowNw_ F rs;3 W. 3aY w¢Y i O w LL w_z u p j Z ¢J W ZQ ¢ O w <w �� N oar w zR �� �WO W Cr wa WO gwm� tcaiw0wJwaw mw�z �W J J 2 O Y u Y� O U O p W W m ^J H O w a Q¢O w m k £ W O z_ U r z_2 W J d 0 ¢ o f K<m O> Z ~ Q W o a W W�I op osz rcN 2t wwm WOzW r O= W �a O Q LLix W IOU2 W Z Z� OW b 6 O W O Q K a LL' W O W U U WWa F-w O z �m OO U Z J o Oa z U� WW JF Nw H�_� IQq lyZ Z n 0 v v WO a o J �, am W0U mW o W J m Z O >,J W O W Ex U 3 3 I�I U O W W OF Oaa a Ji w W Wp¢ O •�, O KLLW _ m e W o m $ XIO r0 WEr W"Wo a<= \� <W> m Z V� O <a =¢ <_ym ❑o J _ ��7, §O ET `iFNW 7W unia+l mO QQ< m =ZW X O< a(9 W W O= z So W �o GENERAC® 60 M installation layout Drawing#01-2090-B (2 of 2) — o — U Wzi ZO m T OF r • — UU N W W (9 Z �O r U O'w K 3� ci z z� ��s 3 Q U F W U,4 �Om O� m mzm LL� m~m Z 7 LLZ 0 Q� aw �Y m Q �W r� mm Wr oof ?U oa N = LL J u U M? Z Nvrw � t 1 O a y Z w 0 i. w y�Q N K N W qO O_ a mm mN LL O N Z �r �Z 0 0 r 0 m Z Nr xZ N 0 ��V N O GENERAC' Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,WI 53189 •generac.com ©2022 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice.Bulletin OL0037SBY-N 03/9/2022 DwCITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 20100 71ST AVENUE NE Permit#: 5283 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31051400202000 DATE OF ISSUANCE. Scope of Work:Install gas line for New 45kW Generator Valuation: 5000.00 OWNER APPLICANT CONTRACTOR AEROSPACE MANUFACTURING Arlington Electric,Inc. Arlington Electric,Inc TECHNOLOGIES 20100 71 ST AVENUE NE 13310 240th St NE 13310 240th St NE ARLINGTON,WA 98223-7447 Arlington Arlington,WA 98223 3604030515 360-403-0515 LIC:ARLINEI833QN EXP: 11/13/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST.TYPE: 1B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 04/13/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans. Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 04/14/2023 Web Only-Mechanical Commercial Plan Review $107.67 04/14/2023 Web Only-Fire System Plan Review $200.00 04/14/2023 Credit Card Service $9.23 04/14/2023 Processing/Technology $25.00 04/14/2023 Gas Piping/Units $15.00 04/14/2023 Mechanical Base $25.00 04/14/2023 Mechanical Misc. $15.00 04/14/2023 Credit Card Service $2.40 Total Due: $399.30 Total Payment: $399.30 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403 3417-Permit Center:360-403-3551 BUILDING PERMIT 20100 71ST AVENUE NE Permit#:5283 PERMIT EXPIRES 180 DAYS AFTER Parcel#:31051400202000 DATE OF ISSUANCE. Scope of Work:Install gas line for New 45kW Generator Valuation:5000.00 OWNER APPLICANT CONTRACTOR AEROSPACE MANUFACTURING Arlington Electric,Inc. Arlington Electric,Inc TECHNOLOGIES 20100 71 ST AVENUE NE 13310 240th St NE 13310 240th St NE ARLINGTON,WA 98223-7447 Arlington Arlington,WA 98223 3604030515 360-403-0515 LIC:ARLINEI833QN EXP: 11/13/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST.TYPE: IB DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow constriction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND N DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED N VIOLATION OF THE LABOR CODE OF THE STATE OF WASHNGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL NSPECTION HAS BEEN MADE AND APPROVAL OR CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC I0/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on Your sales tax return form and coded ty of Arlington#3101. 04/13/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved plans.Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS.SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT PEES Date Description Fee Amount 04/14/2023 Web Only-Mechanical Commercial Plan Review $107.67 04/14/2023 Web Only-Fire System Plan Review $200.00 04/14/2023 Credit Card Service $9.23 04/14/2023 Processing/Technology $25.00 04/14/2023 Gas Piping/Units $15.00 04/14/2023 Mechanical Base $25.00 04/14/2023 Mechanical Misc. $15.00 04/14/2023 Credit Card Service $2.40 Total Due: $399.30 Total Payment: 5399.30 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5283 Permit Date: 04/12/23 Permit Type: COMMERCIAL MECHANICAL Project Name: AMT Aero Gen Install Applicant Name: Arlington Electric, Inc. Applicant Address: 13310 240th St NE Applicant, City, State, Zip: Arlington Contact: Russ Tilton Phone: 3604030515 Email: arlingtonelectric@msn.com Scope of Work: Install gas line for New 45kW Generator Valuation: 5000.00 Square Feet: 74294 Number of Stories: 1 Construction Type: 11113 Occupancy Group: F-1; Factory Mod. Hazard ID Code: Permit Issued: 04/17/2023 Permit Expires: 10/09/2023 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning AEROSPACE 31051400202000 20100 71 ST AVENUE NE MANUFACTURING 344 Transportation TECHNOLOGIES Equipment Contractors Contractor Primary Contact Phone Address Contractor Type License License# Arlington Electric,Inc Arlington Electric 360-403-0515 13310 240th St CONSTRUCTION COA 601 759 192 Inc NE CONTRACTOR Arlington Electric,Inc Arlington Electric 360-403-0515 13310 240th St CONSTRUCTION L&I ARLINEI833QN Inc NE CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 06/06/2023 C12.GAS PIPING Secure location will need to 06/07/2023 06/08/2023 BUILDING Approved PRESSURE TEST check in at the front desk. Plan Reviews Date Review Type Description Assigned To Review Status 04/12/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $107.67 Review (Table 4-1) Enter 1 if permit is for:fire alarm,or fire Web Only-Fire System Plan Review sprinkler $200.00 Credit Card Service $9.23 Processing/Technology $25.00 Gas Piping/Units Enter#of units $15.00 Mechanical Base Permit Fee $25.00 Mechanical Misc. Not otherwise specified $15.00 Credit Card Service $2.40 Total $399.30 Attached Letters Date Letter Description 04/13/2023 Building Permit 04/12/2023 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 04/12/2023 XBP Conf: $307.67 142112344 04/12/2023 142112344 Ameresia Lawlis $9.23 04/13/2023 XBP Conf: $80.00 142196493 04/13/2023 142196493 Ameresia Lawlis $2.40 Outstanding Balance $0.00 Uploaded Files Date File Name 04/17/2023 15062832-20230417 5283 IssuedPermit.pdf 04/12/2023 19679a001c8188224a7f2b8936530ae7 amt aero mp.pdf 04/12/2023 9189ffb822ff5903858d0b44cd82e797 45 kw spec sheet.pdf