Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19405 68TH DR NE_PA26-0264_2026
18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Fire - Fire Alarm Permit Parcel:00482800000104 Permit#:26-0243 Permit Address:17020 SMOKEY POINT BLVD Date Issued:April 2,2026 Description of Work:D Bat Tenant Improvement PERMIT EXPIRES 180 DAYS Valuation:$16400 AFTER DATE OF ISSUANCE. Code Year: OWNER APPLICANT CONTRACTOR Danna Gibson Cameron Bye Seacom Cabling Inc 4028 167th St NW 3014 Hoyt Ave 3014 Hoyt Ave,Everett,WA 98201 4259537476 425-953-7476 danna@dbatsmokeypoint.com cameronbye@callseacom.com cameronbye@callseacom.com registration_number:SEACOCI944DO PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Add exterior horn strobe facing Smokey Point Blvd. /parking lot 2.) Adhere to approved plans. 3.) approved plans shall be onsite for inspections. 4.) Call for inspections. INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance March 25, 2026 Fire System Plan Review(006.345.83.00.02) $271.70 March 26, 2026 Processing/Technology(320.341.43.00.02) $25.00 March 30, 2026 Fire Alarm System Permit(006.322.10.00.01) $300.00 TOTAL: Permit Fees $596.70 $596.70 Credit/Debit Card 484 Payment Successful March 26, 2026 $271.70 $325.00 Credit/Debit Card 497 Payment Successful April 1, 2026 $325.00 $0.00 P A DESIGN CRITERIA 1.THIS TENANT IMPROVEMENT INCLUDES THE INSTALLATION OF 2PENDENT SPRINKLER HEADS •-' j TO PROTECT NEW LIGHT HAZARD AREAS, ^- ' DESIGNED AND INSTALLED IN ACCORDANCE WITH 2O19 NFPA 13,2021 IFC&IBC,AS WELL AS LOCAL JURISDICTION SPECIFICATIONS/GUIDELINES. 1 • 2.WFP SCOPE OFWORK IN THE EDICONTRACTED AREA ONLY.NEW SPRINKLER HEADS TO BE FED FROM EXISTINGG BRANCHLINES.LINES. } - • I � 3.HYDRAULIC CALCULATIONS HAVE BEEN NOT REQUIRED ON THIS TENANT IMPROVEMENT.AREA IS CURRENTLY DESIGNED AND INSTALLED TO PROTECT ORDINARY HAZARD 2,AND TI SPACE IS LIGHT ' �1 HAZARD. P°• 4.WFP ASSUMES THE STRUCTURE TO BEADAQUATE TO SUPPORT THE SPRINKLER SYSTEM.ALL HANGING AND BRACING TO BE PER NFPA 13,2019 EDITION. - { j : C 5OAR S OF THE BUILDING BEING PROTECTED BY WET SPRINKLER SYSTEMS TO BE MAINTAINED AT I'-' �' ' ; / • C NO LESS THAN 40°F YEAR ROUND,UNLESS HEAT TAPE AND TRACE HAVE BEEN UTILIZED. 1111 MAINTAINING THESE AREAS AT 40•F OR GREATER ARE SOLELY THE RESPONSIBILITY OF THE -+ 6.AREAS ON PLAN WHERE SMALL ROOM RULE HAS BEEN USED HAVE BEEN NOTED.RULE WAS • • __ UTILIZED TO BE ABLE TO BE GREATER THAN T-6"OFF ANYONE WALL IN THE ROOM,WHILE MAINTAINING NO MORE THAN 225FP OF COVERAGE PER SPRINKLER HEAD. / C 4 .ALL MATERIAL TO BE UL LISTED AND FM APPROVED FOR FIRE SPRINKLER USE. • ,. .ALL ELECTRICAL WIRING AND MONITORING OF SPRINKLER SYSTEM TO BE DONE BY OTHERS. l • ALL CLEANING AND PAINTING OF PIPING AND BAGGING OF HEADS TO BE DONE BY OTHERS. I .FIRE CAULKING TO BE DONE BY OTHERS. • SPRINKLER OMISSIONS _ r •� . FURNITURE/BUILTINS 4 • •, �•• - SPRINKLERS OMITTED FROM FURNITURE SUCH AS PORTABLE WARDROBE UNITS,CABINETS, , • I / / TROPHY CASES,AND SIMILAR ITEMS NOT INTENDED FOR OCCUPANCY PER 2019 NFPA 139.2.9 ( • , • •I , EXTE IOR SPRINKLER OMITTED 1 A • SPRINKLER OMITTED FROM EXTERIOR PROJECTIONS EXCEEDING 4 FEET PER 2019 NFPA 13 / 8.2.3.1-9.2.3.3 WHEN ALL REQUIRED CONDITIONS HAVE BEEN MET. /• I � • NON-COMBUSTIBLE CONCEALED SPACES Jobsite Photos • •• ` - SPRINKLERS OMITTED FROM NON-COMBUSTIBLE CONCEALED SPACES WITH MINIMAL COMBUSIBLE LOADING AND HAVING NO ACCESS PER 2019 NFPA 13 9.2.1.1 IN NON-CORINKLER SHALL BE INS t/ YS SPRINKLERS SHALL BEINSTALLED AT THE TOP OF THE SHAFT AND UNDER THE FIRST ACCESSIBLE LANDING FROM THE BOTTOM OF THE ELL HE NFPA PACE4.2.1 Existing Riser +- 90 psi �I SPRINKLERS OMITTED FROM THE BOTTOM OF THE STAIRWELL WHEN THE SPACE UNDERNEATH IS BLOCKED SO THAT STORAGE CAN NOT OCCUR PER 2018 NFPA 13 8.3.4.2.3.1 Bathrooms footprint +- 12' x 8' • �� SCHEDULE 40 SPECIFICATIONS 1 C PIPE WALL INTERNAL WEIGHT OF CAPACITY '•S ,• SIZE THICKNESS DIAMETER END PREP TYPES FILLED PIPE GALLONS/F F T. 1 0.133 1.049 THREADED,CUT&ROLL GROOVED,PLAIN END 2.05 0.045 - 1'/. 1) 1.380 THREADED,CUT&ROLL GROOVED,PLAIN END 2.93 0.078 • , 1 h 0.145 1.610 THREADED,CUT 8 ROLL GROOVED,PLAIN END 3.81 0.115 » . • , 2 0.154 iM7 THREADED,CUT&ROLL GROOVED,PLAIN END 5.13 0.190 • ' SCHEDULE 10 SPECIFICATIONS , • PIPE WALL INTERNAL WEIGHTOF CAPACITYIN ' •t -• SZE THICKNESS DIAMETER END PREP TYPES FILLEDPIPE GALLONS/FT. •^ • _ 0.109 1.442 ROLL GROOVED,PLAIN END(BUTT WELDING) 2.52 0.085 ' • r• 1% 0.109 1.682 ROLL GROOVED,PLAIN END(BUTT WELDING) 3.04 0.115 2 0.109 2.15T ROLL GROOVED,PLAIN END(BUTT WELDING) 4.22 0.190 ' 1 • R 2.835 ROLL GROOVED,PLAIN END(BUTT WELDING) 5.89 0.283 / Add 2 Pendent Sprinklers in 2 new Bathrooms • r • 3 0.120 3.260 ROLL GROOVED,PLAIN END(BUTT WELDING) 7.94 0.433 �$- 1 & J • 4 1) 4.280 ROLL GROOVED,PLAIN END(BUTT WELDING) 11.T8 0.T40 R 6 GA 34 6.357 ROLL GROOVED,PLAIN END(BUTT WELDING) 23.03 1.649 } 7 CPVC PIPE _ SIPE WALLIN ZE THIC NESS DIAMETER END PREP TYPES FILLED PIPE GAL TY ONIS FT. 2 Pendent Sprinklers +-8' ceiling 1 I 1 0.214 D 1.101 PLAIN END 0.674 .0495 1'/• 0.268 1.394 PLAIN END 1.079 .0796 - w 11A 302 1.596 PLAIN END 1A17 .1042 12' x 8' approximate footprint 6' x 8' rooms 2 0.372 2.003 PLAIN END 2.223 .1637 ! roof +-25' tall MAX DISTANCE BETWEEN HANGERS TO BE: db1" pipe down to wood 2 sprinklers off 1" drop NOMINAL SIZE 3/4 1 1114 1V2 2 2112 3 4 5 6 8 I • • •'• GRVSTEELPIPE N/A 12-0 12-0 160 15-0 1&0 1&0 15-0 15-0 15.0 15-0 THRD STEEL PIPE NIA 72-0 12-0 12-0 12-0 12-0 12-0 N/A WA NIA N/A - 1 CPVC PIPE SB 8-0 6-0 M 8-0 9-0 1M N/A WA N/A N/A SPRINKLER LEGEND BY M CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# SPACING 2 PENDENT QRSS CHROME 155° 5.6 1/2" RA1414 RELIABLE FlFR56 15'-0X15'-0 Z 2 TOTAL HEADS ON PROJECT AAAA Bathrooms T.I. 1" = 50' HANGING & BRACING City of Arlington Building Department APPROVED Kevin Olander-04/16/2026 No changes authorized unless approved by the Building Official JOB # F26018 CVO LFE FIRE PROTECTION, INC. WF IS S PERMIT# • Vim'-'A•Y^NRMRL•R n•I•TOI• CONTRACT# 832 80TH STREET S.W. 19405 68TH DR NE zAJT/. APPROVAL: `i =0.3•• 22-CG L•vW 3 DRAWN BY: Chuck Bamford EVERETT, WA 98203 DATE: 4/6126 ARLINGTON, WA 98223 �'y EF SCALE:AS NOTED 3 6 0 /9 4 8 6 2 1 R...._.... ...... ...N REVISION DATE:N/A CONTRACTOR#:WOLFEFP9006DD City of Arlington Building Department APPROVED Kevin Olander- 04/16/2026 No changes authorized unless approved by the Building Official Wolfe Fire Protection OFFICE: (360) 794-8621 FAX: (360) 794-3080 SUBMITTAL PACK EQUIPMENT CUT SHEETS WEISS SUITES 19405 68TH DR. NE ARLINGTON, WA 98223 • wASNO MTON W.4" • j PIQ1111111#'@i1 "Mim wo"M a Owles warren Bamford 0434-0392-CG Level 3 Z. AJ �(' • LFe ,1 �1 ........ .r WOLFE FIRE PROTECTION, INC 832 801h STREET SW EVERETT, WA 98203 (360) 794 - 7926 Bulletin 074 January 2023 Rel ® F1 FR56 Series Quick Response Sprinklers K-factor 5.6(80) Features gn • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall,and vertical sidewall deflectors • Low profile,compact design • Available in a wide variety of finishes Product Description Model F1 FR56 Pendent Model F1 FR56 Upright Reliable Model F1 FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C,or HB(reference Technical Bulletin 204). When installed recessed or concealed,the Model F1 FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the Model F1 FR56 Vertical Sidewall Model F1 FR56 technical information on the following pages for specific listings Horizontal Sidewall for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. Note: Not all versions of the product are shown. When fitted with an approved water shield,these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways,and other areas where intermediate level sprinklers are required. Note:This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- Table Aprovides asummary of the approvals and availability of tification Number(SIN), application, performance,and listings/ specific Model F1 FIR series sprinkler configurations.Additional technical information for each sprinkler model is provided on the approval are not otherwise affected. Sprinklers with New frames will include the suffix otherwise in the order. following pages. F1 FR Series Sprinklers Summary Fril• - Sprinkler K-Factor gpm/psi'/2 Max Working Pressure Sprinkler . Model (Ipm/bar'/z) Orientation Listings&Approvals psi(bar) Identification Number(SIN) Upright cULus,FM,LPCB,VdS, 175 12 Intermediate Upright EC,WM,UKCA 250(17)(cULus only) Pendent cULus,FM,LPCB,VdS, 175(12) RA1414 EC,WM,UKCA 250(17)(cULus only) F1 FR56 5.6(80) Concealed Pendent cULus,VdS,EC,WM, 175(12) RA1414 UKCA 250(17)(cULus only) 175(12) 250(17)(cULus only) cULus,FM,LPCB, Vekiaal UKCA www.reliablesprinkler.com Model F1 FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Recessed Escutcheons Style: Model F1 (cULus,LPCB,VdS,CE,WM) Pendent Model F2(cULus,FM,LPCB,VdS,CE, Recessed Pendent WM) Concealed Pendent Model FP(cULus,VdS,CE,WM) Threads: 1/2"NPT or ISO 7-R1/2 Nominal K-Factor:5.6(80 metric) Cover Plate Max.Working Pressure: Model CCP(cULus,VdS(2),CE(2) 175 psi(12 bar) 250 psi(17 bar)(cULus only) Guards&Shields(New Frames)(') Material Specifications F-1 Guard(FM) Thermal Sensor:3 mm Glass Bulb F-5 Guard/Shield Kit(FM) Sprinkler Frame:Brass Alloy F-7 Guard(cULus) Cap:Bronze Alloy F-8 Guard/Shield Kit(cULus) Sealing Washer:Nickel with PTFE S-1 Shield(cULus,FM) Load Screw:Copper Alloy Guards&Shields(Legacy Frames)(') Deflector:Brass Alloy C-1 Guard(FM) Sprinkler Finishes C-5 Guard/Shield Kit(FM) (See Table B) D-1 Guard(cULus,FM) D-4 Guard/Shield Kit(FM) Sensitivity D-5 Guard/Shield Kit(cULus,FM) Quick response S-1 Shield(cULus,FM) Temperature RatingsM Sprinkler Wrenches 135°F(57°C) Model W2(pendent) 155°F(68°C) Model W4(recessed or concealed) 175°F(79°C) Model J(New frame with guard installed) 200°F(93°C) Model JD(Legacy frame with guard 286°F(141°C) installed) Listings and Approvals(') cULus Listed FM Approved LPCB VdS EC WM U KCA:0832-U KCA-CPR-S 5045, 0831-UKCA-CPR-5072(CCP) Notes: 1. 286°F(141°C)temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C(68°C)sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed.See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1 FR56 Pendent Sprinkler Components and Dimensions 3 1/4"[83mm] Threads V8 F1FR_HALF_PEND_INT 03 VH Wrench Flat 2 1/4"[57mm] I Cap/Seal Glass Bulb Assembly (3 mm) Deflector Load Screw 1"[25mm] Shown with Optional S-1 Water Shield(Ordered Separately) Note:Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 Reliable Page 3 of 9 January 2023 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers 2-1/4" 2-1/4" (57 mm)Dia. (57 mm)Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm)Dia. Reducing (49 mm)Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8"(29 mm)at 7/8"(22 mm)at Max.Recess Max.Recess 3/8"(10 mm)at 3/8"(10 mm)at Ir Min.Recess Min.Recess 1-3/4" 1-3 (44 mm) 1" (44 mm) 1-1/4" (25 mm) (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8"(72 mm)Dia. Recess Recess 2-7/8"(72 mm)Dia. Recess Models F1&F1 FIR Pendent Sprinkler Models F1&F1 FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4"(19mm)Nominal Adjustment 1/2"(13mm)Nominal Adjustment F1_REC PEND CCP 2-1/2" 2-1/2" (64 mm)Dia. (64 mm)Dia. Hole in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm)Dia. Reducing (59 mm)Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting Vented Cup to Face of Ceiling Vented Cup to Face of Ceiling 1-1/2"(38 mm)at 1-1/2"(38 mm)at Max.Recess Max.Recess 1"(25 mm)at 1"(25 mm)at Min.Recess I Min.Recess 1" 1" (25 mm) 1/2" (25 mm) 1/2" (12 mm) (12 mm) Minimum Minimum Recess 3-3/16"(78 mm)Dia. Recess Maximum Maximum Recess 3-5/16"(84 mm)Dia. Recess Models F1&F1 FIR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2"(13mm)Nominal Adjustment Model F1 FR56 CCP Conical Concealed Sprinkler 1/2"(13mm)Nominal Adjustment Note:Model FP recessed assemblies may not be used where the (Nominal Cover Plate Projection is 1"(25 mm)) pressure in the space above the ceiling is positive with respect to the protected area.Ensure that the openings in the Model FP cup Note:Model CCP concealed assemblies may not be used where are unobstructed following installation. the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. FP Escutcheon F1 Escutcheon CCP Cover Plate (F2 Similar) Bulletin 074 Reliable Page 6 of 9 January 2023 www.reliablesprinkler.com L�_ i Model W2(upright, pendent) Model J (New frame with guard installed) Model JD(Legacy frame with guard installed,similar but with zinc finish) Model W4 (recessed,concealed pendent) FinishesM Standard Finishes mMO Special Application Finishes Sprinkler F1,F2 and FP(z) CCP Cover Sprinkler F1, F2 and FP(z) CCP Cover Plate(2) Escutcheons Plate(') p Escutcheons Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(-') Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200T(93°C)maximum temperature rated sprinklers only. Installation Maintenance Model F1 FR Series sprinklers must be installed in accordance with Reliable Model F1 FR series sprinklers should be inspected and NFPA13 and the requirements of all applicable authorities having the sprinkler system maintained in accordance with NFPA 25, as jurisdiction. Model F1 FR Series sprinklers must be installed with well as the requirements of any Authorities Having Jurisdiction. the Reliable sprinkler installation wrench identified in this Bulletin. Prior to installation, sprinklers should remain in the original Any other wrench may damage the sprinkler. The Models W2 and cartons and packaging until used.This will minimize the potential W4 wrenches have two sets of jaws. Use the smallest set of jaws for damage to sprinklers that could cause improper operation or that fit on the wrench flats of the sprinkler. A leak tight sprinkler non-operation. joint can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). Do not tighten sprinklers over the maximum recommended Do not clean sprinklers with soap and water, ammonia liquid or installation torque. Exceeding the maximum recommended any other cleaning fluids. Remove dust by gentle vacuuming installation torque may cause leakage or impairment of the without touching the sprinkler. sprinkler. Replace any sprinkler which has been painted (other than factory applied).A stock of spare sprinklers should be maintained to Glass bulb sprinklers have orange bulb protectors or protective allow quick replacement of damaged or operated sprinklers. caps to minimize bulb damage during shipping, handling and Failure to properly maintain sprinklers may result in inadvertent installation. Reliable sprinkler installation wrenches are designed operation or non-operation during a fire event. to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 074 Reliable Page 8 of 9 January 2023 www.reliablesprinkler.com Guarantee For the guarantee,terms, and conditions,visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed EscutcheonO)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F(57°C) [For use with 135°F(57°C) and 155°F(68°C)sprinklers.] • 165°F(74°C) [For use with 175°F(79°C) and 200°F(93°C)sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4(recessed, concealed) • Model J (New frame with guard installed) • Model JD(Legacy frame with guard installed) Notes: 1.286°F(141°C)sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. rn rn rn rn rn z a Bulletin 074 Reliable Page 9 of 9 January 2023 www.reliablesprinkler.com Bulletin 074 January 2023 Rel ® F1 FR56 Series Quick Response Sprinklers K-factor 5.6(80) Features s: • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall,and vertical sidewall deflectors • Low profile,compact design • Available in a wide variety of finishes Product Description Model F1 FR56 Pendent Model F1 FR56 Upright Reliable Model F1 FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C,or HB(reference Technical Bulletin 204). When installed recessed or concealed,the Model F1 FR56 series sprinklers are specifically listed with and may only be installed r Z with listed Reliable escutcheons and cover plates. Refer to the Model F1 FR56 Vertical Sidewall Model F1 FR56 technical information on the following pages for specific listings Horizontal Sidewall for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. Note: Not all versions of the product are shown. When fitted with an approved water shield,these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways,and other areas where intermediate level sprinklers are required. Note:This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- Table Aprovides asummary of the approvals and availability of tification Number(SIN), application, performance,and listings/ specific Model F1 FIR series sprinkler configurations.Additional technical information for each sprinkler model is provided on the approval are not otherwise affected. Sprinklers with New frames will include the suffix otherwise in the order. following pages. F1 FR Series Sprinklers Summary Fril• - Sprinkler K-Factor gpm/psi'/2 Max Working Pressure Sprinkler . Model (Ipm/bar'/z) Orientation Listings&Approvals psi(bar) Identification Number(SIN) Upright cULus,FM,LPCB,VdS, 175(12) RA1425 Intermediate Upright EC,WM,UKCA 250(17)(cULus only) cULus,FM,LPCB,VdS, 175 12 EC,WM,UKCA 250(17)(cULus only) F1 FR56 5.6(80) C01980910d cULus,VdS,EC,WM, 175 12 UKCA 250(17)(cULus only) Hdewall eul:d5'FM 175 12 250(17)(cULus only) cULus,FM,LPCB, 486 UKCA www.reliablesprinkler.com Model FlFR56 Upright Sprinkler SIN RA1425 Technical Specifications Guards&Shields(New Frames) Style:Upright,Intermediate Upright Factory Water Shield(cULus, FM) Threads: 112"NPT or ISO 7-R1/2 F-1 Guard(cULus,FM) Nominal K-Factor:5.6(80 metric) F-3 Guard with Shield(cULus, FM) Max.Working Pressure: 175 psi(12 bar) Guards and Shields(Legacy Frames) 250 psi(17 bar)(cULus only) Factory Water Shield Material Specifications C-1 Guard(FM) Thermal Sensor:3 mm Glass Bulb C-3 Guard with Shield(cULus,FM) D-1 Guard(cULus) Sprinkler Frame:Brass Alloy D-3 Guard with Shield(cULus) Cap:Bronze Alloy Sealing Washer:Nickel with PTFE Sprinkler Wrench Load Screw:Copper Alloy Model W2 Deflector:Brass Alloy Model J(New frame with guard installed) Model JD(Legacy frame with guard Sprinkler Finishes installed) (See Table B) Listings and Approvals Sensitivity cULus Listed Quick response FM Approved -PCB Temperature Ratings VdS 135°F(57°C) EC 155°F(68°C) WM 175-F(79°C) UKCA:0832-UKCA-CPR-S5045 200-F(93°C) 286°F(141°C) Model F1 FR56 Upright Sprinkler Components and Dimensions 3 1/4"[83mm] Load Screw 1 3/8"[33mm] Deflector Glass Bulb I � a (3 mm) F1FR_HALF_UPR_INT � 21/4"[58mm] Wrench Flat A CO RA CO Threads Cap/Seal Assembly Shown with Optional Factory Installed Water Shield (Intermediate Upright) Bulletin 074 Reliable Page 2 of 9 January 2023 www.reliablesprinkler.com L�_ i Model W2(upright, pendent) Model J (New frame with guard installed) Model JD(Legacy frame with guard installed,similar but with zinc finish) Model W4 (recessed,concealed pendent) FinishesM Standard Finishes mMO Special Application Finishes Sprinkler F1,F2 and FP(z) CCP Cover Sprinkler F1, F2 and FP(z) CCP Cover Plate(2) Escutcheons Plate(') p Escutcheons Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(-') Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200T(93°C)maximum temperature rated sprinklers only. Installation Maintenance Model F1 FR Series sprinklers must be installed in accordance with Reliable Model F1 FR series sprinklers should be inspected and NFPA13 and the requirements of all applicable authorities having the sprinkler system maintained in accordance with NFPA 25, as jurisdiction. Model F1 FR Series sprinklers must be installed with well as the requirements of any Authorities Having Jurisdiction. the Reliable sprinkler installation wrench identified in this Bulletin. Prior to installation, sprinklers should remain in the original Any other wrench may damage the sprinkler. The Models W2 and cartons and packaging until used.This will minimize the potential W4 wrenches have two sets of jaws. Use the smallest set of jaws for damage to sprinklers that could cause improper operation or that fit on the wrench flats of the sprinkler. A leak tight sprinkler non-operation. joint can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). Do not tighten sprinklers over the maximum recommended Do not clean sprinklers with soap and water, ammonia liquid or installation torque. Exceeding the maximum recommended any other cleaning fluids. Remove dust by gentle vacuuming installation torque may cause leakage or impairment of the without touching the sprinkler. sprinkler. Replace any sprinkler which has been painted (other than factory applied).A stock of spare sprinklers should be maintained to Glass bulb sprinklers have orange bulb protectors or protective allow quick replacement of damaged or operated sprinklers. caps to minimize bulb damage during shipping, handling and Failure to properly maintain sprinklers may result in inadvertent installation. Reliable sprinkler installation wrenches are designed operation or non-operation during a fire event. to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 074 Reliable Page 8 of 9 January 2023 www.reliablesprinkler.com Guarantee For the guarantee,terms, and conditions,visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed EscutcheonO)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F(57°C) [For use with 135°F(57°C) and 155°F(68°C)sprinklers.] • 165°F(74°C) [For use with 175°F(79°C) and 200°F(93°C)sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4(recessed, concealed) • Model J (New frame with guard installed) • Model JD(Legacy frame with guard installed) Notes: 1.286°F(141°C)sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. rn rn rn rn rn z a Bulletin 074 Reliable Page 9 of 9 January 2023 www.reliablesprinkler.com Pipe HangersiSupports l*)' mc. / Engineered Solutions Two Hole Standoff Hanger and Restrainer Fig. 188R (Formerly Afcon Fig. 514) Size Range:W'through 2" Material:Carbon Steel Finish:Pre-Galvanized per ASTM A653 Service: • Hanger and surge restraint for horizontal CPVC,steel,and copper piping when installed on the top,bottom,and side of the supporting structure. Guide for vertical CPVC,steel,and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete,steel structural members,and other structural members with fasteners which comply with the requirements of NFPA 13. ` C&US Approvals:cULus Listed \ LISTED Patents:No.6,648,278 Installation • Snap hanger over pipe.If needed,squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. ` Feal • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. Easily attaches to wood structure with#10 x T'hex washer head self-threading screw supplied with product. No pre-drilling required. • Bottom of pipe is offset T/2"from the structure.Eliminates wooden spacer blocks. Ordering:Specify CPVC pipe size,figure number and description. Hanger& Restrainer 1.50 Hanger& Guide& Restrainer O Restrainer Installation-Backing Nut Hanger=1-At top fastener Restraint=2-On each fastener Per NFPA-13D and NFPA-13R ANVIL. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-9.18 page 1 SS-SUB-188R-0120220629 i Pipe Hangers & Supports U *OASC V-4 Engineered Solutions Two Hole Standoff Hanger and Restrainer (cont.) Fig. 188R (Formerly Afcon Fig. 514) ° a B ° ° a A a ° ad a a ° E + Oc a a ° a a ° a ° a G a ° ° a°. a° a a a °. d. F D G Hanger and Restrainer Fig.188R:Dimensions(in)•Weight(lbs) CPVC Max.Hanger Approx. Pipe Size A B 0C D E F G Spacing(ft) Weight/100(lbs) 'A 28/4 31/2 1/4 2 1 21/8 11/2 51/2 11 1 213/16 31/2 1/4 23/16 1 2"/16 11/2 6 12 VA 21 A6 31/2 'A 25/16 1 31/4 11/2 61/2 13 Th 36/8 41/4 'A 27116 1 31/2 11/2 7 14 2 311/16 4% 'A 211/16 1 4 Th 8 16 Fig.188R:Listed Fasteners Pipe Wood and Composite Beams Steel(18ga.Minimum) CPVC Screw Supplied or#10 x 1"TEK Screw #14 x 1"TEK Screw or 1/d'x 1"TEK Screw Steel&Copper #14 x 1"TEK Screw or 1/4'x 11/2"Lag Screw #14 x 1"TEK Screw or 1/4'x 1"TEK Screw 0' ANVI L, '441PP� An ASC Engineered Solution SS-9.18 page 2 SS-SUB-188R-v0120220629 S/A 53 Spec Sheet A53 Pipe Specifications A/SA53 N PS 1/4" -30" Schedules 10 through 160, STD, XH and XXH Scope ASTM A53 pipe covers Seamless and Welded, Black and Hot-Dipped Galvanized nominal (average) wall pipe for coiling, bending, flanging and other special purposes and is suitable for welding. Continuous-Welded pipe is not intended for flanging. Purpose for which pipe is intended should be stated on order. Materials and Manufacture The steel for both seamless and welded pipe shall be made by one or more of the following processes: open-hearth, electric furnace, or basic-oxygen. The weld seam of electric-resistance welded pipe in Grade B shall be heat treated after welding. Chemical Requirements Type S Type E Type F (seamless) (electric- (furnace- resistance welded) welded pipe) Grade A Grade B Grade A Grade B Grade A Carbon max. % 0.25 0.30 0.25 0.30 0.3 Manganese % 0.95 1.2 0.95 1.2 1.2 Phosphorous, max. % 0.05 0.05 0.05 0.05 0.05 Sulfur, max. % 0.045 0.045 0.045 0.045 0.045 Copper, max.% 0.40 0.40 0.40 0.40 0.4 Nickel, max. % 0.40 0.40 0.40 0.40 0.4 Chromium, max. % 0.40 0.40 0.40 0.40 0.4 Molybdenum, max. % 0.15 0.15 0.15 0.15 0.15 Vanadium, max. % 0.08 0.08 0.08 0.08 0.08 Hot-Dipped Galvanizing Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process. Weight of coating must not average less than 1.8 oz. per square foot and not less than 1.6 oz. per square foot. Permissible Variations in Wall Thickness The minimum wall thickness at any point shall not be more than 12.5% under the nominal wall thickness specified. Permissible Variations in Weights per Foot Plus or minus 10% Permissible Variations in Outside Diameter Outside Diameter at any point shall not vary from standard specified more than: For NPS 1 1/2 and For NPS 2 and Larger Smaller Sizes Sizes 1/64" 1/32" under 1% over 1%under Tensile Requirements Seamless and Electric-resistance-welded Continuous-Welded Grade A Grade B Tensile Strength, min., 48,000 60,000 45,000 psi Yield Strength, min., psi 30,000 35,000 25,000 Number of Tests Required Seamless and Electric-Resistance-Welded -- Bending, flattening, tensile on one length of pipe from each lot of 500 lengths or less of a size. Continuous-Weld -- Bending, flattening, tensile NPS 1 1/2 & smaller NPS 2 & larger one / 25 tons one / 50 tons Hydrostatic Testing Hydrostatic inspection test pressures for plain end and threaded and coupled pipe are specified. Hydrostatic pressure shall be maintained for not less than 5 seconds for all sizes of seamless and electric-resistance-weld pipe. Mechanical Tests Specified Tensile Test -- Transverse required on ERW for NPS 8 and large. Sending Test (Cold) -- STD and XS-NPS 2 and under XXS-NPS 1 1/4 and under. Degree of Bend Diameter of Mandrel For Normal A53 90 12 x nom dia. of Uses pipe For Close Coiling 180 8 x nom dia. of pipe Flattening Test -- NPS 2 and larger STD and XS. (Not required for XXS pipe.) Lengths Standard Weight Single Random -- 16' - 22'. 5% may be jointers. If Plain Ends -- 5% may be 12' - 16'. Double Random -- Shortest Length 22', minimum average for order 35'. Extra Strong and Double Extra Strong Single Random -- 12' -22'. 5% may be 6' - 12'. Double Random (XS and lighter) -- Shortest Length 22', minimum average for order 35'. Lengths longer than single random with wall thicknesses heavier than XS subject to negotiation. Required Markings on Each Length (On Tags attached to each Bundle in case of Bundled Pipe) Rolled, Stamped, or Stenciled (Mfrs. Option) Name brand of manufacturer Kind of pipe, that is, Continuous Welded, Electric-Resistance-Welded A, Electric-Resistance-Welded B, Seamless A, Seamless B, XS for extra strong, XXS for double extra strong. ASTM 53 Length of pipe General Information Couplings -- Applied handling tight. Couplings, 2" and smaller straight tapped, other sizes taper tapped. Thread Protection -- Applied to pipe 4" and larger. End Finish (unless otherwise specified) -- STD or XS, or wall thicknesses less than 0.500 in. (excluding XXS): Plain and beveled All XXS and wall thicknesses over 0.500 in.: Plain end square cut. .66 Mechanical-TO Bolted Branch Outlets SEE FM �c Vd3 LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 115 top housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30oF to+230oF/-34oC to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180oF/+82oC. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iIIIIC 1I1C® REV_O 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions min a I Size D. Inches +0.13 Inches Inches F Y �Z� �� - - 2 x Y215 d 920N 500 38.1 2.00 2.53 1.61 136 2.0 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4(a) 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a)n 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 w 25 3450 38.1 47 64 41 136 70 1.4 1 Y4(a)to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y Z 2 5 x 'k(a)§d 920N 500 L50 2.21 2.74 _ 1.82 143 2.0 3.4 65 a) 3450 1.5 .1 70 46 1.6 70 1.4 3/a(a)§d 920N 500 i 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 V 20 3450 38.1 55 70 46 143 70 1.4 T 1(a)§n 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 t25 920N 3450 38.1 52 70 46 143 70 1.4 // 1'/4 t(a)0 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1'/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 1/2(a)a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 /2(a)a 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1(a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2'/50 x 15 mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 TOO 3.8 3.7 through 8 x 47200 x 100mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)o 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3/2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/2"BSPT clearly on order. §Vds approved for fire protection services o-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions Weight Each Inches +0.13 Inches Inches Inches Inches Inches inch Lbs. Lbs. E Y �Z� r0 TABLE CONTINUED FROM PAGE 2 - 4 1/2(a)❑ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 r I 3/4(a)❑ 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 w 1(a)a 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 _ 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y4(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 1 Y2(a)tII 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y �Z 2(a)to 920N 4 0 63.5 83 102 100 68 1 17 99 2.3 2.1 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 v 2'/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 w 3450 69.9 73 102 68 186 118 2.9 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)0 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)o 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 - 67 1 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 - 67 194 102 1.9 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 76.1 mm 920 3450 69.9 73 102 ' 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use 2v2(a)t 9zo 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1/2750 x 15 mm 3450 69.9 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 80 3450 88.9 I 97 I 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com iiiCtaILJIiiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions minal Size D. Inches +0.13 Inches y �Z� r- 00 Inches mm mm mm m TABLE CONTINUED FROM PAGE 3 - 1 Yz t 500 2.00 3.78 4.50 3.30 1 8.23 3.25 1 7.0 i 139.7 x 40 920N 3450 50.8 96 114 - 84 1 209 83 3.2 - i I 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- 50 3450 63.5 95 114 84 209 99 4.1 w 6 1/4(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 Yz(a)trl 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 "3.7 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.139.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 232 99 2.7 2.5 Y 7 Z� 2 Yz 500 69.9 110 130 130 94 10.51 118 8.3 3.4 '� 65 920 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 76.1 mm 920 T 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 w 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 1 112 130 1 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 108.Omm 920 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 ' 146 92 239 159 1 .2 _ TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa +.Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with H DPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2'/50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2'BSPT clearly on order. §Vds approved for fire protection services a-PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions Weight Each Inches +0.13 Inches Inches Inches Inches Inches inch Lbs. Lbs. E Y �Z mm 4 -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 - 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 VI 165.1 x 25 920N 3450 38.1 99 116 96 237 70 3.6 V - - 1 Y°II 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 w 1/2(a)tR 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 1 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 1 130 1 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y F Z� 3(8 t 920 500 88.9 110 140 130 92 10.51 135 10.2 8.8 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V T 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 TL 100 3450 114.3 97 1 146 137 92 267 159 4.8 3.8 + 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 w 200 x 50 920 3450 69.9 138 157 159 122 316 114 5.3 5.3 2Y2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 1 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm tt 920 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 1 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal # Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services rt-PCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com ictaill VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and (2)for the Style 920,920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for CvrKV Values: AP = Qz Where: AP = Qz Where: O C 2 Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(psi) V AP=Pressure Drop(Bar) Q = C x AP C =Flow Coefficient Q = K„x AP K =Flow Coefficient j Exaggerated for clarity OutletEquivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K,Values NOMINq AL • . � GROOVED '/z 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1'/< 1.660 50 48 32 42.7 5/z 6 42.9 41.1 1 Y2 1.900 53 53 40 48.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2'/2 2.875 1 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 1 1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. 1"FireLock-Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'dUI1C° 11.02_6 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures—psi/kPa de Vds Size W . Inches/m Inches/mm *lnches/m cpheldule UL IJLC r—MR(Style 920) (Style 920N) dL 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 _ 300 _ 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100mm, 5Y125mm,67150mm and 87200 mm diameter pipe.The Style 931 comes with a 21/2"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. X.A—c-tSUIiC® REV_O 11.02_7 rM1 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 L+tc�u�lC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 0 11.02_L FIRE SPRINKLER PERMIT APPLICATION For Instruction/Checklist,please click here Site Address: 19405 68th Dr NE Project Name: I WEISS SEACAST RESTRO, Project Valuation: 2000 Preferred Contact: O Owner G Applicant O Contractor Project Description: TENANT IMPROVEMENT INCLUDES THE INSTALLATION OF PENDENT SPRINKLER HEADS Owner Details Owner Name: I Weiss Company XI, LLC Office No.: Email Address: L Cell No.: Mailing Address: C City: State: Zip: F Contractor Details Contractor Name: I Wolfe Fire Protection Office No.: 13607948621 Email Address: Permits@WolfeFP.com Cell No.: Mailing Address: 1832 80th St SW City: Everett State: WA Zip: 198203 L&I Contractor License Number: I WOLFEP906DD Expiration Date: 09/12/2026 Primary Contact Information First Name Melissa Last Name I Weber Email Address I Permits@WolfeFP.com O TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 2 $ 75.00 = $ 75 3to5 $ 125.00 = $ � 6to 10 $ 175.00 = $ � 11 to20 $ 225.00 = $ � 21 to 40 $300.00 = $ 41 to 100 $375.00 11 = $ 101 to 200 $475.00 11 = $ 201 to 300 $575.00 IF-= $ > 300 $600.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $600.00 + $ $ Hydraulically Designed Systems Yes O /No 0 Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ �75 ❑ IF NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $ 375.00 — $ 101 to 200 $ 475.00 = $ 201 to 300 $ 600.00 — $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ Hydraulically Designed Systems Yes O / ❑ No Yes =Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ O IF RESIDENTIAL(NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $ 175.00 = $ 11 to 25 $ 225.00 — $ 26+ $ 275.00 — $ > 300 $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ *NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% _ $ PERMIT FEE SUBTOTAL $ O HOOD SUPPRESSION SYSTEM Type of System Cost per Unit Subtotal Pre-Engineered $ 200.00 — $ Custom Engineered $ 275.00 — $ 26+ $ 275.00 — $ > 300 F $625.00 plus $50.00 per 100 additional devices (round up) Total Number of Devices= $625.00 + $ $ *NFPA 13D SYSTEM INSTALLED (NOT REQUIRED) Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ HOOD SUPPRESSION SYSTEM Type of System No. of Unit Cost per Unit Subtotal Pre-Engineered x $ 200.00 — $ Custom Engineered l X $ 275.00 $ PERMIT FEE SUBTOTAL $ STANDPIPE SYSTEM Standpipe Type of No. of Unit Cost per Unit Subtotal Class I—new or existing x $ 150.00 — $ Class II—new or existing x $ 150.00 — $ PERMIT FEE $ SUBTOTAL FIRE PUMP Type of FIRE No. of Unit Cost per Unit Subtotal PUMP Fire PUMP $ 300.00 — $ x PERMIT FEE $ SUBTOTAL SPRAY BOOTHS (105.7) & INDUSTRIAL OVENS (105.7.7) NOTE: SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Unit Cost per Unit Subtotal Pre-Engineered _ $ 150.00 — $ w/documents x Site-built or used w/o $ 250.00 — $ documents x Industrial Oven $ 250.00 — $ x PERMIT FEE $ SUBTOTAL Plan review fee due at time of submittal TOTAL PERMIT FEE $F75 PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ 75 I hereby certify that I am the O Owner Applicant O Contractor and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. Print Name: Melissa Weber Date: 04/06/2026 P A DESIGN CRITERIA 1.THIS TENANT IMPROVEMENT INCLUDES THE INSTALLATION OF 2PENDENT SPRINKLER HEADS •-' j TO PROTECT NEW LIGHT HAZARD AREAS, ^- ' DESIGNED AND INSTALLED IN ACCORDANCE WITH 2O19 NFPA 13,2021 IFC&IBC,AS WELL AS LOCAL JURISDICTION SPECIFICATIONS/GUIDELINES. 1 • 2.WFP SCOPE OFWORK IN THE EDICONTRACTED AREA ONLY.NEW SPRINKLER HEADS TO BE FED FROM EXISTINGG BRANCHLINES.LINES. } - • I � 3.HYDRAULIC CALCULATIONS HAVE BEEN NOT REQUIRED ON THIS TENANT IMPROVEMENT.AREA IS CURRENTLY DESIGNED AND INSTALLED TO PROTECT ORDINARY HAZARD 2,AND TI SPACE IS LIGHT HAZARD. P°• 4.WFP ASSUMES THE STRUCTURE TO BEADAQUATE TO SUPPORT THE SPRINKLER SYSTEM.ALL HANGING AND BRACING TO BE PER NFPA 13,2019 EDITION. - { j : C 5OAR S OF THE BUILDING BEING PROTECTED BY WET SPRINKLER SYSTEMS TO BE MAINTAINED AT I'-' �' ' ; / • C NO LESS THAN 40°F YEAR ROUND,UNLESS HEAT TAPE AND TRACE HAVE BEEN UTILIZED. 1111 MAINTAINING THESE AREAS AT 40•F OR GREATER ARE SOLELY THE RESPONSIBILITY OF THE -+ 6.AREAS ON PLAN WHERE SMALL ROOM RULE HAS BEEN USED HAVE BEEN NOTED.RULE WAS • • __ UTILIZED TO BE ABLE TO BE GREATER THAN T-6"OFF ANYONE WALL IN THE ROOM,WHILE MAINTAINING NO MORE THAN 225FP OF COVERAGE PER SPRINKLER HEAD. / C 4 .ALL MATERIAL TO BE UL LISTED AND FM APPROVED FOR FIRE SPRINKLER USE. • ,. .ALL ELECTRICAL WIRING AND MONITORING OF SPRINKLER SYSTEM TO BE DONE BY OTHERS. l • ALL CLEANING AND PAINTING OF PIPING AND BAGGING OF HEADS TO BE DONE BY OTHERS. I .FIRE CAULKING TO BE DONE BY OTHERS. • SPRINKLER OMISSIONS _ r •� . FURNITURE/BUILTINS 4 • •, �•• - SPRINKLERS OMITTED FROM FURNITURE SUCH AS PORTABLE WARDROBE UNITS,CABINETS, , • I / / TROPHY CASES,AND SIMILAR ITEMS NOT INTENDED FOR OCCUPANCY PER 2019 NFPA 139.2.9 ( • , • •I , EXTE IOR SPRINKLER OMITTED 1 A SPRINKLER OMITTED FROM EXTERIOR PROJECTIONS EXCEEDING 4 FEET PER 2019 NFPA 13 / 8.2.3.1-9.2.3.3 WHEN ALL REQUIRED CONDITIONS HAVE BEEN MET. /• I � • NON-COMBUSTIBLE CONCEALED SPACES Jobsite Photos • •• ` - SPRINKLERS OMITTED FROM NON-COMBUSTIBLE CONCEALED SPACES WITH MINIMAL COMBUSIBLE LOADING AND HAVING NO ACCESS PER 2019 NFPA 13 9.2.1.1 IN NO-COMBUSTIBLESHALL BE INS t/ YS SPRINKLERS SHALL BEINSTALLED AT THE TOP OF THE SHAFT AND UNDER THE FIRST ACCESSIBLE LANDING FROM THE BOTTOM OF THE ELL HE NFPA PACE4.2.1 Existing Riser +- 90 psi �I SPRINKLERS OMITTED FROM THE BOTTOM OF THE STAIRWELL WHEN THE SPACE UNDERNEATH IS BLOCKED SO THAT STORAGE CAN NOT OCCUR PER 2018 NFPA 13 8.3.4.2.3.1 Bathrooms footprint +- 12' x 8' • �� SCHEDULE 40 SPECIFICATIONS 1 C PIPE WALL INTERNAL WEIGHT OF CAPACITY '•S ,• SIZE THICKNESS DIAMETER END PREP TYPES FILLED PIPE GALLONS/F F T. 1 0.133 1.049 THREADED,CUT&ROLL GROOVED,PLAIN END 2.05 0.045 - 1'/. 1) 1.380 THREADED,CUT&ROLL GROOVED,PLAIN END 2.93 0.078 • , 1 h 0.145 1.610 THREADED,CUT 8 ROLL GROOVED,PLAIN END 3.81 0.115 » . • , 2 0.154 2.067 THREADED,CUT&ROLL GROOVED,PLAIN END 5.13 0.190 • ' '. ; . SCHEDULE 10 SPECIFICATIONS , • PIPE WALL INTERNAL WEIGHTOF CAPACITYIN ' •t -• SZE THICKNESS DIAMETER END PREP TYPES FILLEDPIPE GALLONS/FT. •^ • _ 0.109 1.442 ROLL GROOVED,PLAIN END(BUTT WELDING) 2.52 0.085 ' • r• 1% 0.109 1.682 ROLL GROOVED,PLAIN END(BUTT WELDING) 3.04 0.115 2 0.109 2.157 ROLL GROOVED,PLAIN END(BUTT WELDING) 4.22 0.190 ' 1 • R 2.835 ROLL GROOVED,PLAIN END(BUTT WELDING) 5.89 0.283 / Add 2 Pendent Sprinklers in 2 new Bathrooms • r • 3 0.120 3.260 ROLL GROOVED,PLAIN END(BUTT WELDING) 7.94 0.433 �$- 1 & J • 4 1) 4.280 ROLL GROOVED,PLAIN END(BUTT WELDING) 11.78 0.740 R 6 GA 34 6.357 ROLL GROOVED,PLAIN END(BUTT WELDING) 23.03 1.649 } 7 CPVC PIPE _ SIPE WALLIN ZE THIC NESS DIAMETER END PREP TYPES FILLED PIPE GAL TY ONIS FT. 2 Pendent Sprinklers +-8' ceiling 1 I 1 0.214 D 1.101 PLAIN END 0.674 .0495 1'/• 0.268 1.394 PLAIN END 1.079 .0796 - w 11A 302 1.596 PLAIN END 1A17 .1042 12' x 8' approximate footprint 6' x 8' rooms 2 0.372 2.003 PLAIN END 2.223 .1637 ! roof +-25' tall MAX DISTANCE BETWEEN HANGERS TO BE: db1" pipe down to wood 2 sprinklers off 1" drop NOMINAL SIZE 3/4 1 1114 1V2 2 2112 3 4 5 6 8 I • • •'• GRVSTEELPIPE N/A 12-0 12-0 160 15-0 1&0 1&0 15-0 15-0 15.0 15-0 THRD STEEL PIPE NIA 12-0 12-0 12-0 12-0 12-0 12-0 N/A WA NIA N/A - 1 CPVC PIPE SB 8-0 6-0 7-0 8-0 9-0 1M N/A WA N/A N/A SPRINKLER LEGEND BY M CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# SPACING 2 PENDENT QRSS CHROME 155° 5.6 1/2" RA1414 RELIABLE FlFR56 15'-0X15'-0 Z 2 TOTAL HEADS ON PROJECT AAAA Bathrooms T.I. 1" = 50' HANGING & BRACING Approved r� Steve Goforth,Fire Marshal Subject to Field Review 05/07/2026 3:11:48 PM JOB # F26018 WOLF WOLFE FIRE PROTECTION, INC. WE S PERMIT# • Vim'-'A•Y^NRMRL•R n•I•TOI• CONTRACT# 832 80TH STREET S.W. 19405 68TH DR NE °ChirW '" B.,r°" zAJ T/. 1 APPROVAL 0.3•• 22: = -CG L•vW 3 DRAWN BY: Chuck Bamford EVERETT, WA 98203 DATE: 4/6126 ARLINGTON, WA 98223 /� �'y /� EF 7L SCALE:AS NOTED 3 U 0 /9 4 8 V 2 1 R.-.---.-N --_.`-. . REVISION DATE:N/A CONTRACTOR#:WOLFEFP9006DD