HomeMy WebLinkAbout18302 CHAMPIONS DR_PA26-0166_2026 18204 59th Avenue NE
• ' • 14 op
Arlington, Washington 98223
to tt Phone: 360-403-3551
jNG� WASHINGTON
C
Residential - Mechanical Permit
Parcel:00874400008600 Permit#:26-0166
Permit Address:18302 CHAMPIONS DR Date Issued:February 27,2026
Description of Work:Remove/replace gas water PERMIT EXPIRES 180 DAYS
heater AFTER DATE OF ISSUANCE.
Valuation:$2892
Code Year:2021
OWNER APPLICANT CONTRACTOR
Stephanie Mather Sarah Fast Water Heater
18302 CHAMPIONS DRIVE ARLINGTON,WA,
98223 Bean 425 296 0438
8fastwa erhe permits@fastwaterheater.com
smather04@hotmail.com permits@fastwaterheater.com registration_number:FASTWWH750P7
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this
Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance
advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to
allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not
authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a
structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or
executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in
error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation
or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.
It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a
Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on
private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a
separate permit. The property owner shall ensure that the construction project complies with all applicable zoning
codes and regulations.
The property owner shall also ensure that the construction project does not cause any adverse impact on the
surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits
and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the
construction project complies with all applicable design review requirements.
CONDITIONS
1.) Adhere to approved mechanical equipment
2.) Call for final inspection
3.) Permit shall be onsite for inspection
INSPECTIONS
Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire
Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and
provide preference of morning or afternoon inspection.
Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit.
r
Kevin Olander
Building Official
ASSOCIATED FEES
Date Description Paid Date Amount Paid Balance
February 19, Mechanical Base Fee(006.322.10.00.01) $25.00
2026
February 19, Processing/Technology(320.341.43.00.02) $25.00
2026
February 19, Water Heater(Tank) (006.322.10.00.01) $25.00
2026
February 19, Inspection(006.322.10.00.01) $75.00
2026
TOTAL: Permit Fees $150.00 $150.00
Credit/Debit Card 338 Payment Successful February 23, 2026 $150.00 $0.00
18204 59th Avenue NE
• ' • 14 op
Arlington, Washington 98223
to tt Phone: 360-403-3551
jNG� WASHINGTON
C
Residential - Mechanical Permit
Parcel:00874400008600 Permit#:26-0166
Permit Address:18302 CHAMPIONS DR Date Issued:February 27,2026
Description of Work:Remove/replace gas water PERMIT EXPIRES 180 DAYS
heater AFTER DATE OF ISSUANCE.
Valuation:$2892
Code Year:2021
OWNER APPLICANT CONTRACTOR
Stephanie Mather Sarah Fast Water Heater
18302 CHAMPIONS DRIVE ARLINGTON,WA,
98223 Bean 425 296 0438
8fastwa erhe permits@fastwaterheater.com
smather04@hotmail.com permits@fastwaterheater.com registration_number:FASTWWH750P7
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this
Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance
advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to
allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not
authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a
structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or
executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in
error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation
or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.
It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a
Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on
private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a
separate permit. The property owner shall ensure that the construction project complies with all applicable zoning
codes and regulations.
The property owner shall also ensure that the construction project does not cause any adverse impact on the
surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits
and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the
construction project complies with all applicable design review requirements.
CONDITIONS
1.) Adhere to approved mechanical equipment
2.) Call for final inspection
3.) Permit shall be onsite for inspection
INSPECTIONS
Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire
Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and
provide preference of morning or afternoon inspection.
Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit.
r
Kevin Olander
Building Official
ASSOCIATED FEES
Date Description Paid Date Amount Paid Balance
February 19, Mechanical Base Fee(006.322.10.00.01) $25.00
2026
February 19, Processing/Technology(320.341.43.00.02) $25.00
2026
February 19, Water Heater(Tank) (006.322.10.00.01) $25.00
2026
February 19, Inspection(006.322.10.00.01) $75.00
2026
TOTAL: Permit Fees $150.00 $150.00
Credit/Debit Card 338 Payment Successful February 23, 2026 $150.00 $0.00
Residential Gas
' Water Professional Classic
Atmospheric Water Heaters
The new degree of comfort'
Professional Classic°Atmospheric gas
water heaters are engineered for more
hot water at a low operating cost
Efficiency Altitude Certification
• .58- .66 UEF •All models certified up to 5,999 feet
• More hot water at a low operating cost above sea level, some certified up
to 10,000 feet. Consult factory for
Performance specifications
• FHR: 51 - 105 gallons Plus... '
• Recovery:30.3 to 61.0 GPH at a •Side water connections for space
90'F rise, depending on model heating applications available on
Guardian System'"&Sensor select models
• Exclusive air/fuel shut-off device • Easy to light—no matches required
• Maintenance free—no filter to clean • EverKleen®patented system fights
sediment build-up
• Protective control system that • Exclusive Rheemglas®tank lining
disables the heater in the presence of resists corrosion and prolongs tank life
flammable vapor accumulation
• Enhanced flow brass drain valve
•Temperature and pressure relief valve
included
• Factory installed temperature and
Combustion Shut-off System Flame Arrestor Plate pressure relief valve on select models
• Low lead compliant
-- •Standard replacement parts
Maintenance Free Warranty
•6-Year limited tank and parts Professional Classic
Low Emissions warranty Atmospheric
• Eco-friendly burner, low NOx design •With ProtectionPlusO the 6-year limited 29, 30, 40 and
• Meets 40 ng/J NOx requirements tank warranty becomes 10-year 50-Gallon Capacities
*See Residential Warranty Certificate for Up to 60,000 BTU/h
Longer Life complete information
• Premium grade anode rod provides Natural and LP Gas
long-lasting tank protection Units meet or exceed ANSI requirements and have
been tested according to D.O.E.procedures.Units
meet or exceed the energy efficiency requirements O
of NAECA,ASHRAE standard 90,ICC Code and all
state energy efficiency performance criteria. ut
t LEED Point=1
See specifications chart on back.
INTEGRATED HOME
06/22 FORM NO.FROG RH N COMBO Rev.6
Residential Gas
' Water Professional Classic
Atmospheric Water Heaters
The new degree of comfort°
Professional Classic° Atmospheric Specifications
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO.
GASINPUT RECOVERY FIRST HT.TO
T IN THOUS. IN G HOUR HEIGHT HT.TO WATER SIDE WATER UNIFORM
Y NOMINAL RATED BTU/H 90°F RISE.P.H. RATING TO TANK GAS VENT CONN. T&P CONN. SHIP ENERGY
P GALLON GALLON MODEL (GALLONS) VENT HEIGHT DIAM. CONN. SIZE CENTER VALVE SIZE WE FACTOR
E CAPACITY CAPACITY NUMBER NAT. LP NAT. LP NAT.I LP A B C D E F G H (LES) (UEF)
Tall 29 28 PROG29-32N RH63 32 - 32.3 - 63 - 59-3/4 56-7/8 16-1/2 14-1/4 3 or4 8 50-3/4 3/4 110 0.60
Tall 29 28 PROG29-30P RH63 - 30 - 30.3 - 63 59-3/4 56-7/8 16-1/2 14-1/4 3 or4 8 50-3/4 3/4 110 0.60
Tall 40 38 PROG40-36NRH62t 36 - 36.4 - 64 - 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-38NRH62t 38 - 38.4 - 64 ]76
61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58
Tall 40 38 PROG40-40NRH62t 40 - 40.4 - 84 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-36PRH62f - 36 - 36.3 - 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66
Tall 40 38 PROG40-32PRH62f - 32 - 32.3 - 61-1/2 58-1/2 18-1/2 14-1/4 3or4 8 52-1/4 3/4 125 0.59
Tall 50 48 PROG50-40NRH62t 40 - 40.4 - 7662-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-36PRH62t - 36 - 36.4 - 62-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65
Tall 50 48 PROG50-38NRH601 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3or4 8 51-3/8 3/4 150 0.64
Tall 50 48 PROG50-36P RH60t - 36 - 36.4 - 85 61-1/4 58-3/8 20-1/2 14-1/4 3 or4 8 51-3/8 3/4 150 0.64
Short 30 29 PROG30S-30N RH63 30 - 30.3 - 51 - 49-7/8 47 19-3/4 14-1/4 3 or4 8 40-3/8 3/4 112 0.60
Short 40 38 PROG40S-40N RH62t 40 - 40.4 - 66 - 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 40 38 PROG40S-36P RH62t - 36 - 36.4 - 66 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58
Short 1 40 39 PROG40S-38NRH62t 38 1 - 138.4 - 1 65 1 - 1 53-1/4 50-1/4 1 21-3/8 14-1/4 3or4 1 8 44 1 3/4 125 0.58
Short 40 39 PROG40S-35PRH62f - 35 - 35.4 - 65 53-1/4 50-1/4 21-3/8 14-1/4 3or4 8 44 3/4 125 0.58
Short 40 38 PROG40S-34N RH62 34 - 34.3 - 65 - 52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59
Short 40 38 PROG40S-31 P RH62 - 31 - 31.3 - 65 52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59
Short 50 48 PROG50S-40N RH611 40 - 40.4 - 87 - 54-1/4 51-1/8 23-3/4 14-1/4 3 or4 8 44 3/4 186 0.63
Short 50 48 PROG50S-36P RH61t - 36 - 36.4 - 87 54-1/4 51-1/8 23-3/4 14-1/4 3 or4 8 44 3/4 186 0.63
Models with Installed Side Water Connections and Side T&P Valve
Tall 40 38 PROG40-40N RH AX 40 1 - 140.41 - 1 84 1 - 1 63-1/4 1 60 19-1/2 14 3 or 4 8 53-1/2 3/4 134 0.66
Tall 40 38 PROG40-36P RH AX - 36 - 136.41 - 1 84 1 63-1/4 1 60 19-1/2 14 3 or 4 8 53-1/2 3/4 134 0.66
Tall 48 46 PROG48-60N RH AX 60 - 61 1 - 105 - 1 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 168 0.62
Tall 48 46 PROG48-54P RH AX - 54 55 - 105 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 168 0.62
Models with Installed Top T&P Valve
Tall 40 38 PROG40-38N RH62TT 38 1 - 138.41 - 64 1 - 1 61-1/2 58-1/2 19 14-1/4 3 or 4 8 - 3/4 127 0.58
Tall 40 38 PROG40-40N RH62TT 40 - 40.4 - 84 - 63-1/4 60 19-1/2 14 3 or 4 8 - 3/4 135 0.66
Tall 50 48 PROG50-40N RH62TT 40 - 40.4 - 76 - 62-1/2 59-1/4 21-1/2 14-1/2 3 or4 8 - 3/4 165 0.65
Tall 50 48 PROG50-38N RH60TT 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3 or4 8 - 3/4 150 0.64
Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements.
U.�.• H FLUE O ANODE ROD H FLUE O ANODE ROD FLUE ANODE ROD
Fi O H HOT O COLD
tLEED Point WATER , O O COLD WHPTER O O COLD WAITER O WATER
CONNECTION WATER CONNECTION WATER CONNECTION CONNECTION
CONNECTION CONNECTION
F FF� INSTALLED
SEE T&PVALVE
�+I 3/4"N.P.T. 3/4"N.P.T. TOP T&P
RELIEF RELIEF 1-1/2"ABOVE
VALVE VALVE TOP PAN TO
OPENING OPENING CENTER OF
o OPENING
C� C
-C SIDE
AB AB TAPS G AB
1/2" G 1/2" G4
t � v t (Q t
D D I D
Side T&P Models Side Water Connection+Models Top T&P Models
'Side water connection dimensions will vary
based on gallon capacity
40-Gallon Model:I':53-1/2"/J':20"
50-Gallon Model:I':52"/J':20'
in keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100
Roswell,Georgia 30076 • www.rheem.com
INTEGRATED HOME COMFORT
06/22 FORM NO.FROG RH N COMBO Rev.6
Residential Mechanical Application
For Instruction/Checklist,please click here
Site Address: 18302 Cham Pons Dr Arlingtc
Project Name Mather
Project Valuation: 2892
Preferred Contact:
Owner
Contractor
Project Description:
Remove/replace gas water heater
O vmer Details
Owner Nam a Stephanie M other
Hom eNo.: 18302
Em al Address: sm ather04@hotm al.com
Cell No.: 2065566887
M ailing Address: 18302 Cham Pons Dr
City: Arlington
State: WA
Zip: 98223
Contractor Details
Contractor Nam e Fast Water Heater
Office No.: 16120
Em al Address: perm is@fastwaterheater.coi
Cell No.: 4252960438
Mailing Address: 16120 wood invil le-red m cnd i
City: woodinville
State: wa
Zip: 98072
L&IContractor License Num.ber: FASTWWH750P7
Expiration Date: 11-20-2027
Proposed Piping M aerial:
CSST
Brass
Black Steel
Galvanized Steel
Other
Proposed Piping Size:
1/2"
5/8"
3/4"
III
1 1/2"
2"
Distance from Meter to furthest Appliance:
Total BTU's of all Appliances: 40000
Residential m echanical perm is will be assessed a base fee, fee per unit, and inspection fee (plan review
per Table 4-8 m ay be required for certain perm is)
Type of Fixture N o. of Units
Additional Plan Review fees
Air Cond. Unit< or equal to 100Btu/h
Air Cond. Unit>100Btu/h
Air Cond. Unit>500Btu/h
Air Handling Units
Base Mechanical Fee
Boiler<100Btu/h>3hp
Boiler>1 m Ilion Btu/h<50hp
Boiler>1.5 m Ilion Btu/h<50hp
Boiler>100Btu/h 3-15hp
Boiler>500Btu/h 15-30hp
Com m ecial Hoods -Type I
Com m rcial Hoods -Type II
Diffusers
Dryer Ducting
Ductwork(drawings required)
Evaporative Coolers IF
ExhaustNentilation Fans
Fireplace/Insert/Stove
Forced Air Heat<or equal to 100 Btu/h
Forced Air Heat>100 Btu/h
Gas Clothes Dryer IF
Gas Fired Air Conditioning Unit< or equal to 100 Btu/h
Gas Fired Air Conditioning Unit>100 Btu/h
Gas Fired Air Conditioning Unit>500 Btu/h
Gas Piping< or equal to 5 units IF
Gas Piping for each additional unit> 5
Heat Exchangers
Heat Pum pCondensing Unit IF
Hot Water Heat Coils
Miscellaneous Appliance -regulated by m whanical code, not otherwise
specified
Package Units< or equal to 100btu/> 100 Btu
Range/Cook top-Gas Fired
Refrigeration Unit <or equal to 100Btu/h
Refrigeration Unit>10OBtu/h
Refrigeration Unit>500Btu/h
Re-inspection fee
Residential Range Hood
Unit Heaters < or equal to 100 Btu/h
Unit Heaters >100 Btu/h
Variable Air Volum eBoxes (part of air conditioning system)
Wall Heaters - Gas Fired
Water Heater- Gas Fired 1
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use
of the above described property will be in accordance with the laws, rules and regulation of the State of
Washington.
Print Nam a Jordan Johnson
Date: 02/19/2026