Loading...
HomeMy WebLinkAbout18302 CHAMPIONS DR_PA26-0166_2026 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Residential - Mechanical Permit Parcel:00874400008600 Permit#:26-0166 Permit Address:18302 CHAMPIONS DR Date Issued:February 27,2026 Description of Work:Remove/replace gas water PERMIT EXPIRES 180 DAYS heater AFTER DATE OF ISSUANCE. Valuation:$2892 Code Year:2021 OWNER APPLICANT CONTRACTOR Stephanie Mather Sarah Fast Water Heater 18302 CHAMPIONS DRIVE ARLINGTON,WA, 98223 Bean 425 296 0438 8fastwa erhe permits@fastwaterheater.com smather04@hotmail.com permits@fastwaterheater.com registration_number:FASTWWH750P7 PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved mechanical equipment 2.) Call for final inspection 3.) Permit shall be onsite for inspection INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance February 19, Mechanical Base Fee(006.322.10.00.01) $25.00 2026 February 19, Processing/Technology(320.341.43.00.02) $25.00 2026 February 19, Water Heater(Tank) (006.322.10.00.01) $25.00 2026 February 19, Inspection(006.322.10.00.01) $75.00 2026 TOTAL: Permit Fees $150.00 $150.00 Credit/Debit Card 338 Payment Successful February 23, 2026 $150.00 $0.00 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Residential - Mechanical Permit Parcel:00874400008600 Permit#:26-0166 Permit Address:18302 CHAMPIONS DR Date Issued:February 27,2026 Description of Work:Remove/replace gas water PERMIT EXPIRES 180 DAYS heater AFTER DATE OF ISSUANCE. Valuation:$2892 Code Year:2021 OWNER APPLICANT CONTRACTOR Stephanie Mather Sarah Fast Water Heater 18302 CHAMPIONS DRIVE ARLINGTON,WA, 98223 Bean 425 296 0438 8fastwa erhe permits@fastwaterheater.com smather04@hotmail.com permits@fastwaterheater.com registration_number:FASTWWH750P7 PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved mechanical equipment 2.) Call for final inspection 3.) Permit shall be onsite for inspection INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance February 19, Mechanical Base Fee(006.322.10.00.01) $25.00 2026 February 19, Processing/Technology(320.341.43.00.02) $25.00 2026 February 19, Water Heater(Tank) (006.322.10.00.01) $25.00 2026 February 19, Inspection(006.322.10.00.01) $75.00 2026 TOTAL: Permit Fees $150.00 $150.00 Credit/Debit Card 338 Payment Successful February 23, 2026 $150.00 $0.00 Residential Gas ' Water Professional Classic Atmospheric Water Heaters The new degree of comfort' Professional Classic°Atmospheric gas water heaters are engineered for more hot water at a low operating cost Efficiency Altitude Certification • .58- .66 UEF •All models certified up to 5,999 feet • More hot water at a low operating cost above sea level, some certified up to 10,000 feet. Consult factory for Performance specifications • FHR: 51 - 105 gallons Plus... ' • Recovery:30.3 to 61.0 GPH at a •Side water connections for space 90'F rise, depending on model heating applications available on Guardian System'"&Sensor select models • Exclusive air/fuel shut-off device • Easy to light—no matches required • Maintenance free—no filter to clean • EverKleen®patented system fights sediment build-up • Protective control system that • Exclusive Rheemglas®tank lining disables the heater in the presence of resists corrosion and prolongs tank life flammable vapor accumulation • Enhanced flow brass drain valve •Temperature and pressure relief valve included • Factory installed temperature and Combustion Shut-off System Flame Arrestor Plate pressure relief valve on select models • Low lead compliant -- •Standard replacement parts Maintenance Free Warranty •6-Year limited tank and parts Professional Classic Low Emissions warranty Atmospheric • Eco-friendly burner, low NOx design •With ProtectionPlusO the 6-year limited 29, 30, 40 and • Meets 40 ng/J NOx requirements tank warranty becomes 10-year 50-Gallon Capacities *See Residential Warranty Certificate for Up to 60,000 BTU/h Longer Life complete information • Premium grade anode rod provides Natural and LP Gas long-lasting tank protection Units meet or exceed ANSI requirements and have been tested according to D.O.E.procedures.Units meet or exceed the energy efficiency requirements O of NAECA,ASHRAE standard 90,ICC Code and all state energy efficiency performance criteria. ut t LEED Point=1 See specifications chart on back. INTEGRATED HOME 06/22 FORM NO.FROG RH N COMBO Rev.6 Residential Gas ' Water Professional Classic Atmospheric Water Heaters The new degree of comfort° Professional Classic° Atmospheric Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO. GASINPUT RECOVERY FIRST HT.TO T IN THOUS. IN G HOUR HEIGHT HT.TO WATER SIDE WATER UNIFORM Y NOMINAL RATED BTU/H 90°F RISE.P.H. RATING TO TANK GAS VENT CONN. T&P CONN. SHIP ENERGY P GALLON GALLON MODEL (GALLONS) VENT HEIGHT DIAM. CONN. SIZE CENTER VALVE SIZE WE FACTOR E CAPACITY CAPACITY NUMBER NAT. LP NAT. LP NAT.I LP A B C D E F G H (LES) (UEF) Tall 29 28 PROG29-32N RH63 32 - 32.3 - 63 - 59-3/4 56-7/8 16-1/2 14-1/4 3 or4 8 50-3/4 3/4 110 0.60 Tall 29 28 PROG29-30P RH63 - 30 - 30.3 - 63 59-3/4 56-7/8 16-1/2 14-1/4 3 or4 8 50-3/4 3/4 110 0.60 Tall 40 38 PROG40-36NRH62t 36 - 36.4 - 64 - 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58 Tall 40 38 PROG40-38NRH62t 38 - 38.4 - 64 ]76 61-1/2 58-1/2 19 14-1/4 3or4 8 52-1/4 3/4 127 0.58 Tall 40 38 PROG40-40NRH62t 40 - 40.4 - 84 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66 Tall 40 38 PROG40-36PRH62f - 36 - 36.3 - 63-1/4 60 19-1/2 14 3or4 8 53-1/2 3/4 135 0.66 Tall 40 38 PROG40-32PRH62f - 32 - 32.3 - 61-1/2 58-1/2 18-1/2 14-1/4 3or4 8 52-1/4 3/4 125 0.59 Tall 50 48 PROG50-40NRH62t 40 - 40.4 - 7662-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65 Tall 50 48 PROG50-36PRH62t - 36 - 36.4 - 62-1/2 59-1/4 21-1/2 14-1/2 3or4 8 52-1/2 3/4 165 0.65 Tall 50 48 PROG50-38NRH601 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3or4 8 51-3/8 3/4 150 0.64 Tall 50 48 PROG50-36P RH60t - 36 - 36.4 - 85 61-1/4 58-3/8 20-1/2 14-1/4 3 or4 8 51-3/8 3/4 150 0.64 Short 30 29 PROG30S-30N RH63 30 - 30.3 - 51 - 49-7/8 47 19-3/4 14-1/4 3 or4 8 40-3/8 3/4 112 0.60 Short 40 38 PROG40S-40N RH62t 40 - 40.4 - 66 - 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58 Short 40 38 PROG40S-36P RH62t - 36 - 36.4 - 66 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58 Short 1 40 39 PROG40S-38NRH62t 38 1 - 138.4 - 1 65 1 - 1 53-1/4 50-1/4 1 21-3/8 14-1/4 3or4 1 8 44 1 3/4 125 0.58 Short 40 39 PROG40S-35PRH62f - 35 - 35.4 - 65 53-1/4 50-1/4 21-3/8 14-1/4 3or4 8 44 3/4 125 0.58 Short 40 38 PROG40S-34N RH62 34 - 34.3 - 65 - 52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59 Short 40 38 PROG40S-31 P RH62 - 31 - 31.3 - 65 52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59 Short 50 48 PROG50S-40N RH611 40 - 40.4 - 87 - 54-1/4 51-1/8 23-3/4 14-1/4 3 or4 8 44 3/4 186 0.63 Short 50 48 PROG50S-36P RH61t - 36 - 36.4 - 87 54-1/4 51-1/8 23-3/4 14-1/4 3 or4 8 44 3/4 186 0.63 Models with Installed Side Water Connections and Side T&P Valve Tall 40 38 PROG40-40N RH AX 40 1 - 140.41 - 1 84 1 - 1 63-1/4 1 60 19-1/2 14 3 or 4 8 53-1/2 3/4 134 0.66 Tall 40 38 PROG40-36P RH AX - 36 - 136.41 - 1 84 1 63-1/4 1 60 19-1/2 14 3 or 4 8 53-1/2 3/4 134 0.66 Tall 48 46 PROG48-60N RH AX 60 - 61 1 - 105 - 1 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 168 0.62 Tall 48 46 PROG48-54P RH AX - 54 55 - 105 61-3/4 58-1/2 21-3/4 14-3/8 4 11 51-7/8 3/4 168 0.62 Models with Installed Top T&P Valve Tall 40 38 PROG40-38N RH62TT 38 1 - 138.41 - 64 1 - 1 61-1/2 58-1/2 19 14-1/4 3 or 4 8 - 3/4 127 0.58 Tall 40 38 PROG40-40N RH62TT 40 - 40.4 - 84 - 63-1/4 60 19-1/2 14 3 or 4 8 - 3/4 135 0.66 Tall 50 48 PROG50-40N RH62TT 40 - 40.4 - 76 - 62-1/2 59-1/4 21-1/2 14-1/2 3 or4 8 - 3/4 165 0.65 Tall 50 48 PROG50-38N RH60TT 38 - 38.4 - 85 - 61-1/4 58-3/8 20-1/2 14-1/4 3 or4 8 - 3/4 150 0.64 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. U.�.• H FLUE O ANODE ROD H FLUE O ANODE ROD FLUE ANODE ROD Fi O H HOT O COLD tLEED Point WATER , O O COLD WHPTER O O COLD WAITER O WATER CONNECTION WATER CONNECTION WATER CONNECTION CONNECTION CONNECTION CONNECTION F FF� INSTALLED SEE T&PVALVE �+I 3/4"N.P.T. 3/4"N.P.T. TOP T&P RELIEF RELIEF 1-1/2"ABOVE VALVE VALVE TOP PAN TO OPENING OPENING CENTER OF o OPENING C� C -C SIDE AB AB TAPS G AB 1/2" G 1/2" G4 t � v t (Q t D D I D Side T&P Models Side Water Connection+Models Top T&P Models 'Side water connection dimensions will vary based on gallon capacity 40-Gallon Model:I':53-1/2"/J':20" 50-Gallon Model:I':52"/J':20' in keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com INTEGRATED HOME COMFORT 06/22 FORM NO.FROG RH N COMBO Rev.6 Residential Mechanical Application For Instruction/Checklist,please click here Site Address: 18302 Cham Pons Dr Arlingtc Project Name Mather Project Valuation: 2892 Preferred Contact: Owner Contractor Project Description: Remove/replace gas water heater O vmer Details Owner Nam a Stephanie M other Hom eNo.: 18302 Em al Address: sm ather04@hotm al.com Cell No.: 2065566887 M ailing Address: 18302 Cham Pons Dr City: Arlington State: WA Zip: 98223 Contractor Details Contractor Nam e Fast Water Heater Office No.: 16120 Em al Address: perm is@fastwaterheater.coi Cell No.: 4252960438 Mailing Address: 16120 wood invil le-red m cnd i City: woodinville State: wa Zip: 98072 L&IContractor License Num.ber: FASTWWH750P7 Expiration Date: 11-20-2027 Proposed Piping M aerial: CSST Brass Black Steel Galvanized Steel Other Proposed Piping Size: 1/2" 5/8" 3/4" III 1 1/2" 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: 40000 Residential m echanical perm is will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 m ay be required for certain perm is) Type of Fixture N o. of Units Additional Plan Review fees Air Cond. Unit< or equal to 100Btu/h Air Cond. Unit>100Btu/h Air Cond. Unit>500Btu/h Air Handling Units Base Mechanical Fee Boiler<100Btu/h>3hp Boiler>1 m Ilion Btu/h<50hp Boiler>1.5 m Ilion Btu/h<50hp Boiler>100Btu/h 3-15hp Boiler>500Btu/h 15-30hp Com m ecial Hoods -Type I Com m rcial Hoods -Type II Diffusers Dryer Ducting Ductwork(drawings required) Evaporative Coolers IF ExhaustNentilation Fans Fireplace/Insert/Stove Forced Air Heat<or equal to 100 Btu/h Forced Air Heat>100 Btu/h Gas Clothes Dryer IF Gas Fired Air Conditioning Unit< or equal to 100 Btu/h Gas Fired Air Conditioning Unit>100 Btu/h Gas Fired Air Conditioning Unit>500 Btu/h Gas Piping< or equal to 5 units IF Gas Piping for each additional unit> 5 Heat Exchangers Heat Pum pCondensing Unit IF Hot Water Heat Coils Miscellaneous Appliance -regulated by m whanical code, not otherwise specified Package Units< or equal to 100btu/> 100 Btu Range/Cook top-Gas Fired Refrigeration Unit <or equal to 100Btu/h Refrigeration Unit>10OBtu/h Refrigeration Unit>500Btu/h Re-inspection fee Residential Range Hood Unit Heaters < or equal to 100 Btu/h Unit Heaters >100 Btu/h Variable Air Volum eBoxes (part of air conditioning system) Wall Heaters - Gas Fired Water Heater- Gas Fired 1 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Print Nam a Jordan Johnson Date: 02/19/2026