Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19303 45th Dr Ne_P26-0227_2026
City of Arlington 14 (11 (0/1 18204 59th Avenue NE, Arlington, • • Washington 98223 Phone: 360-403-3551 jNG� WASHINGTON C Invoice Number: 26-0272 INVOICE Invoice Date: March 19, 2026 Account Number: 267899236 Bill To: Invoice Questions? Seatown Electric Plumbing Heating and Air, LLC Phone: 360-403-3551 4200 78th St SW Email: ced@arlingtonwa.gov Invoice Due Date: March 19, 2026 Record Number: Permit A26-0227 Parcel Number: 00928200003300 Location: 19303 45TH DR NE Date Description Paid Date Amount Paid Balance March 18, 2026 Mechanical Base Fee (006.322.10.00.01) $25.00 March 18, 2026 Processing/Technology(320.341.43.00.02) $25.00 March 19, 2026 Inspection(006.322.10.00.01) $75.00 March 19, 2026 Forced Air Heat(006.322.10.00.01) $25.00 TOTAL: Permit Fees $150.00 $150.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --------------------------------------------------------- REMITTANCE INFORMATION If you are paying by check, please include this portion with your payment and remit to the address listed on this invoice. Remittance Information Invoice Account Total Due Your payment is due by March 19, 2026 Number Number This Invoice 26-0272 1267899236 $150.00 Seatown Electric Plumbing Heating and Air, LLC 4200 78th St SW 18204 59th Avenue NE • ' • 14 op Arlington, Washington 98223 to tt Phone: 360-403-3551 jNG� WASHINGTON C Residential - Mechanical Permit Parcel:00928200003300 Permit#:26-0227 Permit Address:19303 45TH DR NE Date Issued:March 20,2026 Description of Work:replace furnace PERMIT EXPIRES 180 DAYS Valuation:$5000 AFTER DATE OF ISSUANCE. Code Year:2021 OWNER APPLICANT CONTRACTOR Alexander Jasper Seatown Electric Plumbing Heating and Air,LLC Seatown Services 19303 45TH DR NE ARLINGTOIN,WA,98223 4200 78th St SW 4252701627 permits@seatownservices.com Ajasper408@gmail.com permits@seatownservices.com registration_number: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. It is unlawful to use or occupy a building or structure until a final inspection has been made and approval or a Certificate of Occupancy has been granted. This permit authorizes only the work noted and covers work to be done on private property only. Any construction on public domain (curbs, sidewalks, driveways, marquees, etc.) will require a separate permit. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community. The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. CONDITIONS 1.) Adhere to approved mechanical equipment 2.) Call for final inspection 3.) Permit shall be onsite for inspection INSPECTIONS Inspection Line: 360-403-3417 Call for inspections by 3:30 pm for next day inspection. Please allow 48 hours for Fire Inspections. Please provide the following information when leaving a message: Permit Number, Type of Inspection, and provide preference of morning or afternoon inspection. Inspection Portal: Please login to customer portal and submit for the desired inspection type for the permit. r Kevin Olander Building Official ASSOCIATED FEES Date Description Paid Date Amount Paid Balance March 18, 2026 Mechanical Base Fee(006.322.10.00.01) $25.00 March 18, 2026 Processing/Technology(320.341.43.00.02) $25.00 March 19, 2026 Inspection(006.322.10.00.01) $75.00 March 19, 2026 Forced Air Heat(006.322.10.00.01) $25.00 TOTAL: Permit Fees $150.00 $150.00 Credit/Debit Card 441 Payment Successful March 19, 2026 $150.00 $0.00 City of Arlington 14 to 18204 59th Avenue NE, Arlington, Washington 98223 Phone: 360-403-3551 IN WASHINGTON C May 21, 2026 RE: Permit Inspection Inspection No.: 26-0289 Permit No.: 26-0227 On May 8, 2026 12:OOPM an inspection type of: Residential- Mechanical Final was completed at the property located at 19303 45TH DR NE. The results are as follows: Status: Pass Inspector's Comments: 360-722-2270 and Ajasper408@gmail.com If you have any questions, please contact our building department. Sincerely Brian Grieve CED Inspector TY O City of Arlington 18204 59th Avenue NE, Arlington, • • 1114r(" too Washington 98223 Phone: 360-403-3551 1 G,�0 WASHINGTON N Final Inspection Report Location: 19303 45TH DR NE Building Permit No.: 26-0227 Owner: Alexander Jasper Type of Work: Special Conditions: 360-722-2270 and Ajasper408@gmail.com Construction Code Edition: 2021 2021 Sprinklers: 0 A final inspection has been completed on . All of the required inspection areas meet the Uniform Construction Code requirements as applicable to the type of work: Brian Grieve CED Inspector City of Arlington 14 to 18204 59th Avenue NE, Arlington, Washington 98223 Phone: 360-403-3551 IN WASHINGTON C May 21, 2026 RE: Permit Inspection Inspection No.: 26-0289 Permit No.: 26-0227 On May 8, 2026 12:OOPM an inspection type of: Residential- Mechanical Final was completed at the property located at 19303 45TH DR NE. The results are as follows: Status: Pass Inspector's Comments: 360-722-2270 and Ajasper408@gmail.com If you have any questions, please contact our building department. Sincerely Brian Grieve CED Inspector 0 TR E° Product Data Upflow/Downflow/Horizontal Gas-Fired, 1-Stage and 2-Stage Induced Draft Furnaces with High Efficiency Motor Upflow, Downflow, Horizontal Right/Left Single Stage Two Stage S8BlAO4OM3PSCA/CS8XlAO4OM3PSCA/C S8X2A040M3PSC S8131 B040M2PSCA/C S8X1 B040M2PSCA/C S8X2B060M4PSC S8131 B060M4PSCB/C S8X1 B060M4PSCB/C S8X2B080M4PSC S8131 B080M4PSCB/C S8X1 B080M4PSCB/C S8X2C080M5PSC S8131C080M5PSCA/CS8X1C080M5PSCA/C S8X2C100M5PSC ° S8131C100M5PSCB/C S8X1C100M5PSCB/C S8X2D120M5PSC \ ®� S8131 D120M5PSCA/C S8X1 D120M5PSCA/C 00 o •� � ssxz 0 ® S8X1 ® S8B1 Note:Models may have a "T"in the 12th digit designating they meet California Note:Graphics in this document are for less than 40 ng/J(NOx)emissions requirements. representation only.Actual model may differ in appearance. May 2024 22-1959-1 F-EN 1 � n N = TECH NO LOG I ES' 0 MWE® Table of Contents General Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features and Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 AirflowTables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 CFM Versus Temperature Rise. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 WiringDiagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 FieldWiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2 22-1959-1 F-EN 0 TRANE® General Features NATURAL GAS MODELS Central Heating furnace designs are certified by Intertek for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable,cycle tested,heavy gauge tubular aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a discharge of gas fumes to the outside. BURNERS Multiport, Inshot burners will give years of quiet and efficient service.All models can be converted to L.P.gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers,gas valve,flame control and includes self diagnostics for ease of service. ENERGY EFFICIENT OPERATION Air-TiteTI cabinet design is certified to<1%air leakage per ASHRAE 193 "Method of Test for Determining the Airtightness of HVAC Equipment." AIR DELIVERY The 9 speed constant torque blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. STYLING Heavy gauge steel and "wrap-around"cabinet construction is used in the cabinet with baked- on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control lights the main burners upon a demand for heat from the room thermostat.Complete front service access. a. Low energy power venter b.Vent proving pressure switches. 22-1959-1 F-EN 3 0 TRANE® Features and Benefits 80%AFUE on S8*1 and S8X2 FURNACE MODELS Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter,easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 4-WAY MULTI-POISE S8*1 -8 SKU's — Upflow/Downflow/Horizontal Left/Horizontal Right S8X2-6 SKU's —Upflow/Downflow/Horizontal Left/Horizontal Right Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure REGULATORY All models are airtight; 1%or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34" high open vestibule for ease of installation and service DIMENSIONS Widths are industry standard: 14.5", 17.5",21" and 24.5" Depth remains approximately 28" Cabinet is compatible with industry standard coils,as well as,other accessories INTEGRATED FURNACE CONTROL Setup/Status/Diagnostics/Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR ALUMINIZED STEEL HEAT EXCHANGER VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable,easy to clean, housing Single piece belly band/motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise FOUR-WAY MULTI-POISE (UPFLOW,DOWNFLOW, HORIZONTAL LEFT AND RIGHT) Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options 4 22-1959-1 F-EN 0 TRANS° Accessories Table 1. Accessories Model Number Description Use with BAYHANG Horizontal Hanging Kit All Furnaces BAYLIFTB Dual Return Kit(B size extension) B Cabinet Furnaces BAYLIFTC Dual Return Kit(C size extension) C Cabinet Furnaces BAYLIFTD Dual Return Kit(D size extension) D Cabinet Furnaces BAYBASE205 Downflow Subbase All Furnaces in Downflow orientation B Cabinet Modular Blowers in Downflow/ BAYFLTR203 Horizontal Filter Kit Horizontal C Cabinet Modular Blowers in Downflow/ BAYFLTR204 Horizontal Filter Kit Horizontal BAYFLTR205 Horizontal Filter Kit D Cabinet Modular Blowers in Downflow/ Horizontal BAYFLTR206 Filter Access Door Kit(Downflow only) All Furnaces in Downflow orientation BAYSF1165*(a) 1"SlimFit Box with MERV 4 Filter All Furnaces All furnaces when used in side return BAYSF1255* 1"SlimFit Filter and Insulated Frame application B Cabinet furnaces only when in bottom return application FLRSF1255 1"Filter replacement(Qty 12) BAYSF1255* BAYVENT600A Internal venting kit B,C,and D Furnaces in Downflow orientation BAYVENT800B Masonry Chimney Vent Kit All Furnaces BAYSWT21AHALTAA High Altitude Pressure Switch Kit S8*lA04OM3P*,S8*1B040M2P* BAYSWT22AHALTAA High Altitude Pressure Switch Kit S8X2A040M3P* BAYSWT14AHALTAB High Altitude Pressure Switch Kit S8*1C080M5P*,S8*1C100M5P*, S8*1D120M5P* BAYSWT15AHALTAA High Altitude Pressure Switch Kit S8*lB06OM4P*,S8*1B080M4P* BAYSWT16AHALTAB High Altitude Pressure Switch Kit S8X2C080M5P* BAYSWT17AHALTAA High Altitude Pressure Switch Kit S8X2B060M4PSAAA BAYSWT18AHALTAA High Altitude Pressure Switch Kit S8X2B080M4P* BAYSWT19AHALTAA High Altitude Pressure Switch Kit S8X2C100M5P* BAYSWT23AHALTAA High Altitude Pressure Switch Kit S8X2B060M4PSAAB&later, S8X2B060M4PTAAA&later BAYSWT24AHALTAA High Altitude Pressure Switch Kit S8X2D120M5P* BAYLPSS400* Propane Conversion Kit with Stainless Steel All Furnaces Burners PIP02095 U fitting for gas piping All Furnaces for right hand gas entry (a) Airflow greater than 1600 CFM requires dual returns 22-1959-1 F-EN 5 0 TRANS° Product Specifications MODEL S8*1A040M3PSC S8*1B040M2PSC S8*1B060M4PSC S8*1B080M4PSC A/C(a) A/C(a) B/C(a) B/C(b) Type Upflow/Horizontal/ Upflow/Horizontal/ Upflow/Horizontal/ Upflow/Horizontal/ Downflow Downflow Downflow Downflow RATINGS(c) Input BTUH 40,000 40,000 60,000 80,000 Capacity BTUH(ICS)(d) 32,300 32,500 48,700 65,100 Temp.Rise(Min.-Max.)OF 30-60 30-60 30-60 30-60 AFUE-Rating(d) 80 80 80 80 Return Air Temp.(Min.-Max.) OF 550F-80OF 550F-80OF 550F-80OF 550F-80OF BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter-Width(in.) 11 X 8 11 X 8 11 X 8 11 X 8 No.Used 1 1 1 1 Speeds(No.)(e) CTM-9 CTM-9 CTM-9 CTM-9 CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance See Fan Performance Table Table Table Table Motor HP 1/2 1/3 3/4 3/4 R.P.M. 1050 1050 1050 1050 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 6.4 4.1 9.2 9.2 COMBUSTION FAN-Type PSC PSC SP SP Drive-No.Speeds Direct-1 Direct-1 Direct-1 Direct-1 Motor RPM 3300/3162 3300/3225 3300 3300 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 0.30 0.30 1.40 1.40 Inducer Orifice 1.20 1.15 1.40 2.15 FILTER-Furnished? No No No No Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-14X25-tin. 1-16X25-tin. 1-16X25-1in. 1-16X25-tin. VENT PIPE DIAMETER-Min.(in.)(f) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER-Type Aluminized Steel Aluminized Steel Aluminized Steel Aluminized Steel Gauge(Fired) 20-19 20-19 20-19 20-19 ORIFICES-Main Nat.Gas Qty.-Drill Size 2-45 2-45 3-45 4-45 L.P.Gas Qty.-Drill Size 2-56 2-56 3-56 4-56 GAS VALVE Redundant-Single Stage Redundant-Single Redundant-Single Stage Redundant-Single Stage Stage PILOT SAFETY DEVICE-Type 120 V SiNi Igniter 120 V SIM Igniter 120 V SiN1 Igniter 120 V SIM Igniter BURNERS-QTY 2 2 3 4 POWER CONN.-V/Ph/HZ(9) 120/1/60 120/1/60 120/1/60 120/1/60 Ampacity(Amps) 8.5 5.6 13.1 13.1 Max.Overcurrent Protection 15 15 15 15 (Amps) PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Uncrated(in.) 34 x 14.5 x 28.75 34 x 17.5 x 28.75 34 x 17.5 x 28.75 34 x 17.5 x 28.75 6 22-1959-1 F-EN 0 TR/WE° Product Specifications MODEL S8*1A040M3PSC S8*1B040M2PSC S8*1B060M4PSC S8*1B080M4PSC A/C(a) A/C(a) B/C(a) B/C(b) Crated(in.) 35.5 x 16.5 x 30.87 35.5 x 19.5 x 30.87 35.5 x 19.5 x 30.87 35.5 x 19.5 x 30.87 WEIGHT Shipping(Lbs.)/Net(Lbs.) 102/94 128/120 128/120 137/129 (a) Central Furnace heating designs are certified to ANSI Z21.47-latest edition. (b) Central Furnace heating designs are certified to ANSI Z21.47-latest edition. (0 For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. (d) Based on U.S.government standard tests (e) 9 Speed constant torque ECM Blower Motor. (f) Refer to the Installer's Guide. (9) The above wiring specifications are in accordance with National Electric Code,however,installations must comply with local codes. MODEL S8*1C080M5PSC S8*1C100M5PSC S8*1D120M5PSC A/C(b) B/C(a) A/C(a) Type Upflow/Horizontal/ Upflow/Horizontal/ Upflow/Horizontal/ Downflow Downflow Downflow RATINGS(b) Input BTUH 80,000 100,000 120,000 Capacity BTUH(ICS)(c) 64,700 80,700 98,000 Temp.Rise(Min.-Max.)OF 30-60 30-60 35-65 AFUE-Rating(c) 80 80 80 Return AirTemp.(Min.-Max.) OF 550E-80OF 550E-80OF 550E-80OF BLOWER DRIVE DIRECT DIRECT DIRECT Diameter-Width(in.) 11 X 11 11 X 11 11 X 11 No.Used 1 1 1 Speeds(No.)(d) CTM-9 CTM-9 CTM-9 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table Motor HP 1 1 1 R.P.M. 1050 1050 1050 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 10.9 10.9 10.9 COMBUSTION FAN-Type PSC PSC PSC Drive-No.Speeds Direct-1 Direct-1 Direct-1 Motor RPM 3300/2971 3300/2680 3300/3025 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.30/0.43 0.33/0.58 0.33/0.57 Inducer Orifice 1.80 2.50 2.15 FILTER-Furnished? No No No Type Recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-20 X 25-1 in. 1-20 X 25-1 in. 1-24 X 25-1 in. VENT PIPE DIAMETER-Min.(in.)(e) 4 Round 4 Round 4 Round HEAT EXCHANGER-Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge(Fired) 20-19 20-19 20-19 ORIFICES-Main Nat.Gas Qty.-Drill Size 4-45 5-45 6-45 L.P.Gas Qty.-Drill Size 4-56 5-56 6-56 GAS VALVE Redundant-Single Stage Redundant-Single Stage Redundant-Single Stage PILOT SAFETY DEVICE-Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS-QTY 4 5 6 22-1959-1 F-EN 7 aMANE Product Specifications MODEL S8*1CO80M5PSC S8*1C100M5PSC S8*1D120M5PSC A/C(b) B/Clai A/C(a) POWER CONN.-V/Ph/HZ M 120/1/60 120/1/60 120/1/60 Ampacity(Amps) 14.1/14.2 14.1/14.4 14.1/14.4 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Uncrated(in.) 34 x 21 x 28.75 34 x 21 x 28.75 34 x 24.5 x 28.75 Crated(in.) 35.5 x 23 x 30.87 35.5 x 23 x 30.87 35.5 x 26.5 x 30.87 WEIGHT Shipping(Lbs.)/Net(Lbs.) 142/134 144/136 160/152 (a) Central Furnace heating designs are certified to ANSI Z21.47-latest edition. (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. (_) Based on U.S.government standard tests (d) 9 Speed constant torque ECM Blower Motor. (e) Refer to the Installer's Guide. M The above wiring specifications are in accordance with National Electric Code,however,installations must comply with local codes. Model S8X2A040M3PSC(a) S8X2B060M4PSC(a) S8X2B080M4PSC(a) Type Upflow/Horizontal/Downflow Upflow/Horizontal/Downflow Upflow/Horizontal/Downflow RATINGS(b) 1st Stage Input BTUH 26,000 39,000 52,000 1st Stage Capacity BTUH(ICS) 20,900 31,500 42,500 2nd Stage Input BTUH 40,000 60,000 80,000 2nd Stage Capacity BTUH(ICS)W 32,200 48,700 65,000 1st Stage Temp.Rise(Min.-Max.)OF 20-50 20-50 25-55 2nd Stage Temp.Rise(Min.-Max.)IF 30-60 30-60 30-60 AFUE(%)(c) 80 80 80 Return Air Temp.(Min.-Max.) IF 55OF-80OF 55OF-80OF 55OF-80OF BLOWER DRIVE DIRECT DIRECT DIRECT Diameter-Width(in.) 11 X 8 11 X 8 11 X 8 No.Used 1 1 1 Speeds(No.)(d) CTM-9 CTM-9 CTM-9 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table Motor HP 1/2 3/4 3/4 R.P.M. 1050 1050 1050 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 6.4 9.2 9.2 COMBUSTION FAN-Type PSC PSC PSC Drive-No.Speeds Direct-2 Direct-2 Direct-2 Motor RPM 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.30 0.30 0.33 Inducer Orifice 1.20 1.40 1.75 FILTER-Furnished? No No No Type Recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-14X25-Iin. 1-16X25-Sin. 1-16X25-Iin. VENT PIPE DIAMETER-Min.(in.)(e) 4 Round 4 Round 4 Round HEAT EXCHANGER-Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge(Fired) 20-19 20-19 20-19 8 22-1959-1 F-EN 0 TR/WE° Product Specifications Model S8X2A040M3PSC(a) S8X2B060M4PSC(a) S8X2B080M4PSC(a) ORIFICES-Main Nat.Gas Qty.-Drill Size 2-45 3-45 4-45 L.P.Gas Qty.-Drill Size 2-56 3-56 4-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE-Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS-QTY 2 3 4 POWER CONN.-V/Ph/HZ(f) 120/1/60 120/1/60 120/1/60 Ampacity(Amps) 8.5 12.0 12.0 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Uncrated(in.) 34 x 14.5 x 28.75 34 x 17.5 x 28.75 34 x 17.5 x 28.75 Crated(in.) 35.5 x 16.5 x 30.87 35.5 x 19.5 x 30.87 35.5 x 19.5 x 30.87 WEIGHT Shipping(Lbs.)/Net(Lbs.) 102/94 132/124 137/129 (a) Central Furnace heating designs are certified to ANSI Z21.47-latest edition. (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. (0 Based on U.S.government standard tests (d) 9 Speed constant torque ECM Blower Motor. (e) Refer to the Installer's Guide. M The above wiring specifications are in accordance with National Electric Code,however,installations must comply with local codes. Model S8X2C080M5PSC(a) S8X2C100M5PSC(a) S8X2D120M5PSC(a) Type Upflow/Horizontal/Downflow Upflow/Horizontal/Downflow Upflow/Horizontal/Downflow RATINGS(b) 1st Stage Input BTUH 52,000 65,000 84,000 1st Stage Capacity BTUH(ICS) 41,800 52,300 67,800 2nd Stage Input BTUH 80,000 100,000 120,000 2nd Stage Capacity BTUH(ICS)W 64,900 80,600 98,000 1st Stage Temp.Rise(Min.-Max.)IF 30-60 25-55 30-60 2nd Stage Temp.Rise(Min.-Max.)IF 30-60 30-60 35-65 AFUE(%)(0 80 80 80 Return Air Temp.(Min.-Max.) IF 550F-80OF 55°F-80OF 550F-80OF BLOWER DRIVE DIRECT DIRECT DIRECT Diameter-Width(in.) 11 X 11 11 X 11 11 X 11 No.Used 1 1 1 Speeds(No.)(d) CTM-9 CTM-9 CTM-9 CFM vs.in.w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table Motor HP 1 1 1 R.P.M. 1050 1050 1050 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 10.9 10.9 10.9 COMBUSTION FAN-Type PSC PSC PSC Drive-No.Speeds Direct-2 Direct-2 Direct-2 Motor RPM 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.30 0.33 0.33 Inducer Orifice 1.80 2.50 2.15 FILTER-Furnished? No No No 22-1959-1 F-EN 9 0 MAKE Product Specifications Model S8X2C080M5PSC(a) S8X2C100M5PSC(a) S8X2D120M5PSC(a) Type Recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-20 X 25-1 in. 1-20 X 25-1 in. 1-24 X 25-1 in. VENT PIPE DIAMETER-Min.(in.)(e) 4 Round 4 Round 4 Round HEAT EXCHANGER-Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge(Fired) 20-19 20-19 20-19 ORIFICES-Main Nat.Gas Qty.-Drill Size 4-45 5-45 6-45 L.P.Gas Qty.-Drill Size 4-56 5-56 6-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE-Type 120 V SiN1 Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS-QTY 4 5 6 POWER CONN.-V/Ph/HZ(f) 120/1/60 120/1/60 120/1/60 Ampacity(Amps) 14.1 14.1 14.1 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(IN.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Uncrated(in.) 34 x 21 x 28.75 34 x 21 x 28.75 34 x 24.5 x 28.75 Crated(in.) 35.5 x 23 x 30.87 35.5 x 23 x 30.87 35.5 x 26.5 x 30.87 WEIGHT Shipping(Lbs.)/Net(Lbs.) 142/134 144/136 160/152 (a) Central Furnace heating designs are certified to ANSI Z21.47-latest edition. (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. (0 Based on U.S.government standard tests (d) 9 Speed constant torque ECM Blower Motor. M Refer to the Installer's Guide. M The above wiring specifications are in accordance with National Electric Code,however,installations must comply with local codes. 10 22-1959-1 F-EN 0 TRANE° Airflow Tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SCFM/Watts 592/40 342/43 93/46 2 SCFM/Watts 666/48 467/56 268/65 70/74 3 SCFM/Watts 687/49 493/59 299/69 105/78 4 SCFM/Watts 938/100 788/111 638/123 488/134 338/146 S8*1A040M3PSC 5 SCFM/Watts 1006/119 870/131 733/144 597/156 461/169 S8X2A040M3PSC 6 SCFM/Watts 1068/140 944/154 820/167 696/181 573/194 7 SCFM/Watts 1174/181 1066/196 957/211 848/226 740/241 8 SCFM/Watts 1167/194 1098/219 1029/244 960/269 891/294 9 SCFM/Watts 1556/398 1474/416 1392/435 1310/453 1228/471 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SCFM/Watts 526/34 2 SCFM/Watts 744/54 533/63 322/72 110/81 3 SCFM/Watts 820/68 662/81 504/94 346/106 188/119 4 SCFM/Watts 967/97 811/110 654/122 498/135 341/148 S8*1B040M2PSC 5 SCFM/Watts 997/104 840/116 687/129 533/142 380/154 6 SCFM/Watts 1052/119 911/133 771/148 630/162 490/176 7 SCFM/Watts 1099/134 968/150 837/165 706/180 575/196 8 SCFM/Watts 1168/157 1047/174 926/191 805/208 684/225 9 SCFM/Watts 1303/214 1196/233 1088/252 981/271 874/290 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SCFM/Watts 596/38 287/42 2 SCFM/Watts 851/70 667/81 483/92 299/102 115/113 3 SCFM/Watts 1142/141 1018/156 893/172 769/187 644/203 4 SCFM/Watts 1196/160 1079/176 961/192 844/208 726/224 S8*1 B060M4PSC 5 SCFM/Watts 1362/220 1258/239 1154/257 1050/276 946/294 S8X2B060M4PSC 6 SCFM/Watts 1416/250 1319/269 1221/288 1124/307 1026/327 7 SCFM/Watts 1495/287 1402/307 1309/327 1216/347 1123/367 8 SCFM/Watts 1574/337 1487/357 1401/378 1314/399 1228/420 9 SCFM/Watts 1983/659 1899/670 1815/680 1730/691 1646/701 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SCFM/Watts 552/34 160/34 2 SCFM/Watts 891/82 720/93 549/105 378/117 207/129 3 SCFM/Watts 1123/141 996/157 869/173 742/189 615/205 4 SCFM/Watts 1344/224 1240/224 1136/263 1033/283 929/302 S8*1B080M4PSC 5 SCFM/Watts 1479/290 1384/312 1290/333 1196/354 1102/375 S8X2B080M4PSC 6 SCFM/Watts 1583/354 1496/376 1408/398 1321/420 1234/442 7 SCFM/Watts 1654/405 1572/428 1491/451 1409/474 1327/496 8 SCFM/Watts 1818/542 1739/561 1661/581 1582/600 1503/619 9 SCFM/Watts 1926/645 1841/656 1756/667 1670/679 1585/690 22-1959-1 F-EN 11 aTRANE` Airflow Tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SUM/Watts 728/44 358/49 2 SUM/Watts 809/53 540/63 271/74 3 SUM/Watts 1440/185 1273/201 1105/218 938/234 770/250 4 SUM/Watts 1536/220 1385/238 1233/257 1081/275 929/293 S8*1COSOMSPSC 5 SUM/Watts 1689/278 1552/299 1414/320 1277/342 1140/363 S8X2CO8OM5PSC 6 SUM/Watts 1792/326 1661/348 1530/371 1400/394 1269/417 7 SUM/Watts 1899/373 1771/397 1643/422 1515/446 1387/471 8 SUM/Watts 2094/500 1985/527 1875/554 1766/582 1656/609 9 SCFM/Watts 2533/931 2414/932 2295/933 2176/933 2058/934 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SUM/Watts 821/55 442/55 2 SUM/Watts 1359/163 1195/180 1031/198 868/215 704/233 3 SUM/Watts 1602/246 1461/268 1321/290 1180/312 1040/334 4 SUM/Watts 1807/336 1678/362 1550/388 1421/414 1292/440 S8*iC 100M 5PSC 5 SUM/Watts 1827/345 1700/371 1572/398 1444/425 1317/451 S8X2C100M5PSC 6 SUM/Watts 1925/395 1800/423 1675/451 1550/479 1425/508 7 SUM/Watts 2102/503 1985/534 1869/566 1752/597 1635/628 8 SUM/Watts 2222/602 2115/635 2008/667 1901/700 1794/732 9 SUM/Watts 2458/896 2351/913 2245/930 2138/947 2032/964 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap Static 0.1 0.3 0.5 0.7 0.9 1 SUM/Watts 1469/184 912/126 355/68 2 SUM/Watts 1429/175 1165/171 900/168 636/164 371/160 3 SUM/Watts 1567/215 1401/232 1235/248 1069/264 903/280 4 SUM/Watts 1858/334 1731/361 1605/388 1478/415 1351/441 S8*i D 12OM5PSC 5 SUM/Watts 2004/418 1890/447 1776/476 1662/505 1548/534 S8X2D12OM5PSC 6 SUM/Watts 2110/488 2004/518 1898/549 1792/580 1686/611 7 SUM/Watts 2245/596 2148/629 2052/662 1956/695 1860/729 8 SUM/Watts 2440/765 2345/794 2250/824 2155/854 2060/884 9 SUM/Watts 2536/882 2431/904 2325/927 2220/949 2114/972 12 22-1959-1 F-EN 0 TRANE® CFM Versus Temperature Rise SSBI/SSXI Furnaces have one stage heating S8X2 Furnaces have two stage heating.First Stage is Low heating and Second Stage is High heating. Table 2. S8B1/S8X1 CFM Versus Temperature Rise Model 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 S8*1A040M3PSC 59 49 42 37 33 30 S8*1B040M2PSC 59 49 42 37 33 30 S8*1B060M4PSC 56 49 44 40 37 34 32 S8*1B080M4PSC 59 54 49 46 42 40 37 35 33 S8*1C080M5PSC 59 54 49 46 42 40 37 35 33 S8*1C100M5PSC 57 53 49 46 44 41 39 37 35 34 32 31 S8*1D120M5PSC 59 56 52 49 47 44 42 40 39 37 Table 3. S8X2 — Low Heat CFM Versus Temperature Rise—First Stage(Low)Heating Model 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 S8X2A040M3PSC 48 39 32 28 S8X2B060M4PSC 56 47 40 35 31 28 S8X2B080M4PSC 55 48 43 39 35 32 30 28 S8X2C080M5PSC 55 48 43 39 35 32 30 28 S8X2C100M5PSC 60 53 48 44 40 37 34 32 30 S8X2D120M5PSC 57 52 48 44 41 39 37 35 33 31 Table 4. S8X2 — High Heat CFM Versus Temperature Rise—Second Stage(High)Heating Model 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 S8X2A040M3PSC 59 49 42 37 33 30 27 S8X2B060M4PSC 56 49 44 40 37 34 32 S8X2B080M4PSC 59 54 49 46 42 40 37 35 33 S8X2C080M5PSC 59 54 49 46 42 40 37 35 33 S8X2C100M5PSC 57 53 49 46 44 41 39 37 35 34 32 31 S8X2D120M5PSC 59 56 52 49 47 44 42 40 39 37 22-1959-1 F-EN 13 0 TRANE° Wiring Diagrams NOTES' 1.IF ANY OF THE ORIGINAL WIRING SUPPLIED WITH THIS FURNACE MUST BE REPLACED,IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105°C.WIRES 12,18,20,48,49,50,51,92&93 MUST BE RATED T0250°C. 2.FOR PROPER AIRFLOW IN COOLING/HEAT PUMP MODE,"Y1"ON THE THERMOSTAT MUST BE CONNECTED TO'Y1' OF THE IFC.SEE IOM FOR FIELD WIRING. 3.THE INDOOR BLOWER MOTOR AIRFLOW TABLES ARE LOCATED IN THE IOM.TO CHANGE AIRFLOW USE THE MENU/OPTIONS BUTTONS. S8B1 4.LINE CHOKE AND WIRE BK/28 ONLY USED ON MODELS WITH 1 HP MOTORS. 5.FLAME SENSE TEST PADS:1 VDC=1 MICROAMP.FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT IS USED AND THE VOLTAGE SUPPLIED TO THE FURNACE, ALTERNATE WIRING DIAGRAM-BLOWER MOTOR THE ACCEPTABLE RANGE S 0.75,3 MICROAMPS. I 6.IF APPLICABLE CONNECTION FOR FACTORY PROGRAMMING ONLY. _M P. yus4 ® ���p_�rWI 58B1peDURNER �M RDLLDUTa ��I/51TxERMA<uMiT � Yu4vYe»Yv51 I 1.—..—..—..—..— c..—. LJ j :eio c•1 BIl4 I I BKI, IUI x . r--.�aa-._ -.� REeAe-Fxa L r—vw — U ww4 MOTOR uvE — Y. weRDNJNU' rPC L� vuwxn ..—.. KWIBUMAHM] N HU a s wt ro RrrvH T s wH p K/L �"re p mD�No� 'leN WH W D 11 —a € „ I — ,'1:'`r'x I cEal a To FloGEN He Her xaa aE lir N�•I KI2] BK13 ,`KIJ I cuo FL TOR R W b e Hl1] To..ciAPss Owwta ILIZEt .NSO 1 aE. ucE rc MOTOR TN ND cE I a R MGENOTE ? 8 z x I H21 F 7 GO H12 scc Hl21 FL W1 K/ eon Gxo IGN D ®® IG B AM02 L.. 'oJ uwxn rLlu AC Lnwuz & wn KwH " RIWHIS INTEGRATED FURNE CONTROL US] ELECTRICALRATING INPUT:24VAC,W Hz. H LINE TNSSEC CURREW:450MA. rran�PROaE N NEUTRAL +MV LOAD WH112 GND GROUND MV OUTPUT;1SA@24 VAC THERMALr-E;;�7n-E� IFC HLO HIGH INO OUTPUT'.22FLA,3.SLFA ACHLI HIGNPUT IG�OUTPUT:2.OA�TVA n INPUT CIto 7`WER DO R: FACTORY PS PRESSURE SWITCH WH WHITE LINE 14.HUMIDIFIER LRA®LEAVER YL YELLOW 2AL WIRING INPUT HUMIDIFIERTAIR CLEANER �L IND INDUCER OR ORANGE —'--ALTERNATE sEExoTEs (DRY CONTACTS) IFC INTEGRATED k4A)(.LOAD20 VAC WAY120VAGBE GR GREEN FURNACE 24 USE OR IEO VAC WAY BE BR BROWN •.�.�.LINE FIELD CONTROL USED RO REO _...........241 WIRING RAF REVERSE USE SA BL BLUE AIRFLOW ION HOT SURFACE FRS FLAME ROLLOUT TIMINGS dam• IGNITER e"A FUSE TH 24VAC'HOT) PREPURGE:S SEC. SWITCH TR 24VAC COMMON) INTERPURGE:%SEC. FLAME NOLLOUT1 PA Mvc MAIN VALVE POSTPURDES SEC DEFAULT BLOWER MOTOR TAP SELECTIONS RAF REVERSE 6"-6 LC LINE CHOKE ��FP FrAME PROBE COMMON ION WARM UP:20SEC. r AIRFLOW MV MAIN VALVE IAP:3',TFI:55EC. n coe(CON-1 PAN):TAP TIN TRANSFORMER RETRIES'.2 RECYCLES:10 co(COOLING/HP):TAPT ILI INDUCER LIMIT HEAT ON DELAY:UP TO AO SEC. n HT(wsHEA1): P SWIITTCHURE T GROUND "INTERNAL THERMAL PROTECTION IREP COOL ON DELAY:O SEC. ION IGNTER AUTO RESTART:W MIN. 1 Stage Inducer with CTM Blower Motor FP FIAME PROBE AUTO RESTART PURGE:60 SEC. Sbbe Codes [nF Blower Ta for CorNnuous Fan Ens Flame tleleUed,shauM nor be DreseM IdL Itlle LOP C1. Blower Ta MCom ressor Motle E6.1 Votiage reversed polarity HE Healing HLP H Blower Te for Heati Motle E6.2 Bad Greereme EP Blowr Tep Number rU� Run Teal Motle E6.3 (1)Igniter may Mae LGF COnrinuoum Fen Enor Catles (2)IgniMropen LPI Ccoling1Heat Pump Motle EDI Le OflR—mam-,rues, El.l Gas valve iseneryitttl wfientlsMultl beol! dFt Defmsr Motle E2.1 R xaetlatl Failetl to est 0arre EDo Fleme current is lwv,bN still Menu Option3 E2.2 Recycles exceetletl lbss of strong enoughbalbwopmretim 0— Orientation ealablarlad llameor PS epenx10) Ell (1)Gas vslven.—MIzed Err Active Alarm form E2.3 Ges Valvarmienmmizmtlwben0 (2)Gasvalve relay aWckclmeE L" Le"6 Farb IT,Clear, sheoltlbemxceedmtla0erlOhmes E12 Open fuse • _ Held Ort.,N.n 5 sec) E3.I Shaletl Pressure SWNl: 'fL7yJ1"•�SC!`S C. Cede Release Number E3.2 Open Pressure SWllcb Y• End Ceeb,g DO Gas,(arm) E04 Open Thermal Llmlt Rollo.SWOtl:, HGd Heat 01 Way(sec) a Reverse Aim.I.- D346340POl REV H 14 22-1959-1 F-EN aMWE Wiring Diagrams NOTES: 120V 60 Hz.1 PH 1.IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED,IT MUST BE WITH WIRE POWER SUPPLY PER LOCAL CODE HAVING A TEMPERATURE RATING OF AT LEAST 105°C.WIRES 12,18,20,48,49,50,51,92,93 MUST BE RATED TO 250°C. JUNCTION Box 2.COOLING I HEAT PUMP SYSTEMS-Y1 ANDIOR Y2 MUST CONNECT FROM THE THERMOSTAT TO THE IFC LOW 'H !N VOLTAGE TERMINALS FOR PROPER AIRFLOW.SEE IOM FOR FIELD WIRING. !GND I 3.THE INDOOR BLOWER MOTOR AIRFLOW TABLES ARE LOCATED IN THE IOM. SHX1 i r— r I S8X 1 TO CHANGE AIRFLOW USE THE MENU/OPTIONS BUTTONS. 4.LINE CHOKE AND WIRE BK/280NLY USED ON MODELS WITH 1 HP MOTORS. 5.FLAME SENSE TEST PADS:1 VDC=1 MICROAMP.FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT IS USED AND THE VOLTAGE SUPPLIED TO yl THE FURNACE.THE ACCEPTABLE RANGE IS 0.75-3 MICROAMPS. ---FA yu4 r YD4T TOeox BHxYW 3 Yll YW yuRL yu51 I I F— LINE CHOKE l PANEL LOOP YU4 u K z z BK ows YU4ay�-S��YI/51J K r...... J vu exoixn o u4 L HI4 Moron i IFC Llxa- 3 BK ax BK I ms 1 BK YIfNHO VWM 3P 4 WH j RANHI5 I macWH H1 YY m° ° ,. POR "R s�ocu coos I 1 WH WH ,° r.c.a.w-QR. uxa. 1 VENT 3�'— I a MOTOR p 3° Its g at 1 i u I Ixc jBK 8K3 INDUCER) BK1 WH _e 2 ,SI rJ IIG IGN — BLOWER `rc� y WH WH F� ux cxors I IJ I I 9K MOTOR * 1 RDNVH DNJH BK] rarveL Loon I a 2 VLIWH VLAMN KJ2T p r 3 BLIWH BLNYH T 4 BKANH BKNYH iT - Tars 5 ORANH ORIWH ... 6 BL BL I� I I iLlie+ n3u i xT z s IINo-cT[al I ILI 1 I TNS M v ee Usep �o warm eexmea fi: ���'' 2 BL H -mHsnr sxRlNK I s 3 OR HTi Z 24v 120vH121 Mvc 5� BL BK Wi W I B 6 RD Y ® o co 7, GR �F ®® I v 8 RD BURNER DI DNrt12 H 9 VL R M BOX GND YIN HR4 y� Uys,� I rr 10 WH— INTEGRATEDL C GAS P 11 VALVE FURNACE CONTROL ELECTRICAL RATING ww INPUT'24VAC.WW H LINE TNSSEC.CURRENT:450MA. N NEUTRAL 111 LOAD 11 F�t.:rWW12 GAD GROUND MV WTPUi:t54®24VAC L..— m IFC HLO 0 TP LIMIT IND OUTPUT',2.2 FU,3.5 U. O HLI HIGH LIMIT IGNNPOUTPUT:2.0 A@120 VAC d INPUT CIRC.BLOWER OUTPUT : W R G BC Yw1 Y2 Ekilikh PB PRESSURE SWITCH 14,5FIA,25LRA a120VAC THERMOSTAT INPUT HUMIDIFIER BNR CLEAN ER g IND INDUCER BK BIA K R REEN LINE FACTORY sse xoTez IFC INTEGRATED (DRY CONTACTS) MAX LOAD:t-0A0 MAY B WH WHITE BR BROWN 24V WIRING FURNACE 2/VAC OR 120 VAC MAY BE YL YELLOW RD RED ......LINE FIELD CONTROL USED FLAME ROLLOUT2 THERMAL LIMIT 24V WIRING IF REVERSE FUSE:SA AIRFLOW VL YL 9 IGN HOTNITER FACE FRS FLAME ROLLOUT TH 24VAC'COT) TIMINGS d IGNITER �'� FUSE SWITCH TR -AC BCD MON) PREPURGE:0 SEC. MVC MANIA- INTERPURGE:50 SEC. COMMON POST PURGE:5SEC. o-Fo RAF REVERSE 6'�'a LC LINE LHOKE FP FLAME PROBE MVC MAIN VALVE IGN WARM UP'20SEC. RAF-2 RAF-1 r AIRFLOW ME TRANSFORMER MP:3',TFI'SSEC ILI INDUCER LIMIT RETRIES.2 RECYCLES 10 �F VL�VL INPUT HEAT ON DELAY:UP TO 30 SEC. o� PSSPRRIECHURE T GROUND "INTERNAL THERMAL PROTECTION IGN IGNITER COOL ON DELAY:O SEC. FP FUME PROBE AUTO RESTART:BO MIN. 1 Stage Inducer With CTM Blower Mohr AUTO RESTART PURGE:60 SEC. Stoo.CoEee jh0 Heat ORDNay(sec) E3.1 SMUed Pressure Switch 11 Idle [OF Nmrer TapWC,driuous Fan E3.2 Open Pressure Swtrnh VL Heal'mg COP CI. Blmrer Tap for lst EOH Open Thermal Ll.It RI SYmdr EP Blmver Tap Number .,I.Compressor Motle orR.—AidWw SwtrG1 [OF Cominuous Fan C2. Blower Tapfor2na EDS Flame de d,—la not be present CPI CcclinglHeat Pump Motle O)Igniteropen Stage Compressor Mode E6.1 Voltage reversed polarity PS DEFAULT BLOWER MOTOR TAP SELECTIONS drE DefMM OA xEP xl owe. Blr Tap ror Heating Motle E6 Bea.2 Grounairg FLAME_ROLLOUTi Menu Options .U� Run Teet Motle E5.3 (1)IgnOer relay(ails VL R COF 0— OrienWibn (CONSTANT FAN):TAP CPi(FIRST STAGE COOLING):TAP Error Caaes CP2(SECOND STAGE COOLING):TAP 7 E. Ad,AN,Nenu E01 Ld1o1 IROOrinkmal hllures El.l Gasvalve Uenergizedwhenit should be M HT(GAS HEAT):TAP LSF Lastll Nub(To Clear, E2.1 RetryexceedA(Fai1earoest0ame) EOB Flame aeent is law.but All � YL Hold Option Button 5secl E2.2 Recyclesexceeaetl IM of strong en0Who,diwopereti0n C, Coae Release Number estadisbea Aa—PS open xl0) EII (1)Gas calve noleroryized COd Codirg ORDelay lseq E23 Ges Valve rMenergUatl wfien it (2)Ges retie releysNW Gosetl OdU o..r Unit sho,Ia ba exueeaea anerlotimee E12 oenmeeI D345844POl REVF 22-1959-1 F-EN 15 aTRANE` Wiring Diagrams 120,60 Hz.1 PH NOTES: POWERSUPPLYPPff LOCALCODE CQ�( 1 LEAST05C WIRES 12.18,48N9,50,51.N93,G AS SUPPLIED wITH ANT 94IREQURE A TEMPERATURE RATING OF ATCE M TLEEAAST 50'CR HAVINGATEMPERATURE RATING OF Ai rJUNCTION BO% 1T1 jH N7 /8X2 2.FOR PROPER AIRFLOW IN COOLINGIHEAT PUMP MODES,YIANDIOR Y2 MUST CONNECT FROM THE THERMOSTAT TO THE IFC LOW VOLTAGE TERMINAL STRIP, I y.IGND� 3.FOR COOLING ONLY SYSTEMS,LEAVE YI-0 JUMPER IN PLACE ON THE IFC FOR CORRECT LED READOUT. 4.FOR HEAT PUMP SYSTEMS,REMOVE THE Yt-0 JUMPER,CONNECT'O'FROM THE THERMOSTAT TO YI'ON THE IFC LOW VOLTAGE TERMINAL STRIP FOR CORRECT LEDAGE READOUT. L T ,_I r,_I I r S.B SHOWN SINGLE STAGE HEATING THERMOSTAT,ATALL TIMR.S SECOND ND TERMINALS ERATON TIE WILL EGITAU RTHEIALSTRIP.HTD WILL ELAY I j} ICI BE SHOWN ABUSE SEVEN SEGMENT DISPLAY AT HANGS ARROW STAGE OPERATION WILL BEGIN AFTER THE OL MENU AN DELAY HAS COMPLETED. 6.AIRFLOW TABLES ARE LOCATED IN THE IOM.TO CHANGEAIRFLOW,REFER TO THE INTEGRATED FURNACE CONTROL MENU AND OPTIONS D, TINECH RFLOWANDBLOW 0ND UVS. O DO ].LINE C U45 AN T WIRE RE N ONLY USE T O MOTELS WR MODELS. LINE CHOKE B.WIRE SENANTRAF-2AS NOTPRESENTON P.FUMEC MODELS. 9.PLANE USSENSETE VOLTAG:1VTC=IMIOTHE.F ECURRENTCAN VARY DEPENDING O.75l MIC VON THAT ,,,=o,,,,„,T� PANELLOOP USETANO THE VOLTAGE SUPPLIED TO THE FURNACE.THE ACCEPTABLE NANGE IS O.T53 MICROAMPS. �""I�"r--/4�Ir- • BK B _ TIK L J S8X2 ^ �" ��"n'11 IFC .._.._.. 1. BK N 'S. sax�vuaa r+ Z vla,J I `1xE 3 .s v ou 77 TM 2 BK xO Ilws�iwwws���� I 1 • BK ONp� vuvE I ,x 4• WH atoEUDTWER R cm 3 WH wa I uxe. �WH WH 2 LLB IeN,H 1 BK 1 VENT BK HI 2 BK 2 MOTOR iR". 3 RD 3 (INDUCER) wwws BLOWER P NER 401 pH.—coeE I ION 5 WH WH IGN WH— a� MOTOR P Q'n f'IN r BK 3 i i I 1 RDANH RDNJH 2 YLANH YLNVH —Hi * 3 BLAAI BLM/H BE S 9 BKAN H BKNdH net Li}Sp' s 6 ORANH ORANH N z I� II I O o 6 BL BL M zs� I w 1 I TINS c 2 BL W O IS, 3 OR ry o 4 VL 24v 20v nxeawreeawK I N 6 BL B RD I I�NUM �la�lel eX 6 Ix�l��l van, Psa T' BR see no BE use ,p 3 w O - Iwo"cEal I O o 8 GR BURNER o R H$ Hen.srvrelrvrc I Mn 9 RD 1J- E BOX GNO w 10 BRSBE L 2xrzl x 11 W 3 WH ®®IOx xn I I P52 O ae L.._ JELU w Y L E_ w,TO % ol "®RTT 9;0�®"M 5 ww, aeaaxaa CIRCe a Ea m IFC r� IN EFREssuPF zswnr},s7 ac Te ea FLAME_ROLLOUT2 THERMAL_LIMIT . LINE A IF ratio oruaxAee suV,SE� zovA®NNY-ss VL VL LINE 'on wlT x F.A.wn H p Egg' RAF-2 RAF-1 IIITEa wee �^mFuuEPROBE RNPur VL u VL VUBE ED _ E'^"L t xeawae T caouxp F1 FLANE,RSOBE S 2 Stage Inducer with CTM Blower Motor _ Jo Has,srnoa Slates Codes HDa Heel OR DEI re` BE n Premure Svntpl Stee IdL mill ISd IrAerSeeTeb ON OmThennel LlmR.ROIIWI SwifcM1,o,PrwNe Airflow Sit,, 1st Stage Healing CDP CI. BDwer Tap Wr,st Slags ..Flame tleleded,shcUldndbe resell VL DEFAULT BLOWER MOTOR TAP SELECTIONS HE2 2ntl Sla a Heagn Caxpreesa Motle BE I Vdta a revereetl ola' 11 &aver TOP Number 12 Bbwer Tap for 2nd Sage SDI Bed Gmundin9 COF(CONSTANT FAN):TAP [DF Continuous PER Compressor Motle F6.3 (1)Igniler relay faib CL1(FIRST STAGE COOLING):TAP CtI tat Stage Cooling HEP HI. 3—Ta fond Sce Heatln 2lO: CL2(SECOND STAGE COOLING):TAP [L2 2nd Soge Curling H2 Bldwer Tap for 2nd doge Heating ET.I ISt stage gas III(MAIL)is energized when it should bed( FLAME_ROLLOUTI P51 HT1(FIRST STAGE HEAT):TAP HpI tat So eHeat Pum .u� Run Tesl Motle E. Fbme Frrent is bw betstlll strop enou hWallav retlm VL HT2(SECOND STAGE HEAT):TAPS xP2 2nd Bra eHeat Pum Error Codes E09 Oen Inducer Limit SwilcAa COMensate Svnlch dFE Tefroaf Mode EOI Lour of IRO or'mdmal failures EII (1)lsl stage gas valve not every zed when it ehWd be Men.0 ons E2., Rein,exweded FEW to Ru Aare (2)1atsWge gas valve relay sWd closed 0.� One— E2.2 Recyde xceedec(Ioss of eetabllahed (3)2nd siege gas vahre relay sWd,closed E.. Acflve Abrm Menu flameor PBo en xl0 (4)2ndstage gas valveenergizetl LfiP Last 6 Faufls(TOClsar, E2.3 I stSMge Gas Valve rM energized when it when flshould notbe Hdd Optbn Budon Ssec) sM1ald be exreedetl atlerf0 times (5)2nd stage gasvalve notenerg'vxd [. Code Re lease Number E3.1 $M1orletl Pressure SMilcM1,lsl SWe when gshad be COd Coding ON Delay(sec) E3.2 Oen pressure Swflch,lst Sla E12 Open Wse I. Ouc UnOT a E3.R Sholled Pressure Switch2nd Sloe 16 22-1959-1 F-EN 0 TRAME° Electrical Connections Make wiring connections to the unit as indicated on enclosed wiring diagram.As with all gas appliances using electrical power,this furnace shall be connected into a permanently live electric circuit.It is recommended that furnace be provided with a separate"circuit protection device" electric circuit.The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code,ANSI/NFPA 70,if an external electrical source is utilized.The integrated furnace controiis polarity sensitive.The hot leg of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram. Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace. I � ' FIRE HAZARD! Failure to follow this Warning could result in property damage,severe personal injury,or death. This Warning applies to installations with a flammable refrigeration system.The furnace must be powered except for service.The furnace shall be installed and connected according to installation instructions and wiring diagrams that are provided with the evaporator coil. Field Wiring FIELD WIRING DIAGRAM FOR S8B1/S8X1 SINGLE STAGE HEATING THERMOSTAT,ONE/TWO STAGE AC OR HEAT PUMP Two Stage Thermostat Furnace Outdoor Unit NOTES: (No Transformer) 1) HP=Wiring used for Heat Pump systems. 2) Y1 and/or Y2 must connect from the thermostat to the IFC for proper airflow. W1 W1 HP X2 3)AITCONT824 thermostats do not require the use of X2. 4) Y2 not available for S861. option®1 R R R HP Condensate ------------------ Switch ------------G------- G Q B B B ;LY2 Y2 - ------- -- Y2-- ----- option r2 Y1 Y1 Y1 Y1 Condensate ----- ------------- ----------------- -------- --------- --------------------—--- Switch --- ---�p HP 0 Two Stage FIELD WIRING DIAGRAM FOR S8X2 TWO STAGE Thermostat Fumace HEATING THERMOSTAT,ONE/TWO STAGE AC OR HEAT PUMP NOTES: 1) HP=Wiring used for Heat Pump systems. Outdoor Unit 2)Y1 and/or Y2 must connect from the thermostat to the IFC W2 W2 (No Transformer) for proper airflow. 3) Remove Y1-0 jumper for HP systems.O terminal must be connected as shown for gas heating operation during defrost. X2 W1 W1 HP 4) If the thermostat does not have W2,or there are not enough conductors jumper W1 to W2 at the IFC. Option#1 R R HP R 5)AITCONT824 thermostats do not require the use of X2. Condensate --- --------- ---• Switch --- -------------- B Q G G Retl p AfrFD Field Wiring EAC B B 'LY2 using eAc Terminals Green ---• g� Y2Y2 Blue .......................................................... Black (- Option m Y 1 Y1 Replace the factory installed 35va transformer with the 50va transformer i�l suppliedwith theair cleaner.Connect to FAC terminals on the IFC per ___ ________ _____O HP 0 the wldng diagram. 22-1959-1 F-EN 17 0 TRANE° Outline Drawing Table 5. 14.5", 17.5",21" and 24.5"Width Cabinets v - M M \ M d N Vcp c.0 c9 cp 9� M_ cn aD cfl cD c.0 cfl 00000000000000000000u00000000a000 w � wwww 00000a000000u0000000u0000000aa000 o � "' c") "' "' w M = _ _ _ Q V ego �m ° -- - . m o i o w i m o i 7 - u .d a sg 18 22-1959-1 F-EN Notes 22-1959-1 F-EN 19 TRANE® Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. 0%. us Intertek Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 22-1959-1 F-EN 30 May 2024 Supersedes 22-1959-1 E-EN (March 2023) ©2024 Trane Residential Mechanical Application For Instruction/Checklist,please click here Site Address: 19303 45th Dr NE Project Name: I Jasper Project Valuation: 5000 Preferred Contact: Owner Contractor Project Description: Furnace replacement i Owner Details Owner Name: Alexander Jasper Home No.: 19303 45th Dr NE Email Address: Ajasper408@gmail.com Cell No.: 3607222270 Mailing Address: 19303 45th Dr NE City: Arlington State: WA Zip: 98223 Contractor Details Contractor Name: Seatown Services Office No.: 14252701627 Email Address: permits@seatownservices.cc Cell No.: 14252701627 Mailing Address: 14200 78th St SW City: Mukilteo State: I WA Zip: 98275 L&I Contractor License Number: I SEATOEH767NZ Expiration Date: 88/09/2026 Proposed Piping Material: O CSST O Brass 0 Black Steel Galvanized Steel Other Proposed Piping Size: 1/2" 5/8" 3/4" III 1 1/2" 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Units Additional Plan Review fees Air Cond. Unit< or equal to 100Btu/h Air Cond. Unit>100Btu/h Air Cond. Unit>500Btu/h Air Handling Units Base Mechanical Fee Boiler<100Btu/h>3hp Boiler>1 million Btu/h<50hp Boiler>1.5 million Btu/h<50hp Boiler>100Btu/h 3-15hp Boiler>500Btu/h 15-30hp Commercial Hoods -Type I Commercial Hoods -Type II Diffusers Dryer Ducting Ductwork(drawings required) Evaporative Coolers ExhaustNentilation Fans Fireplace/Insert/Stove Forced Air Heat< or equal to 100 Btu/h 1 Forced Air Heat>100 Btu/h Gas Clothes Dryer Gas Fired Air Conditioning Unit<or equal to 100 Btu/h Gas Fired Air Conditioning Unit>100 Btu/h Gas Fired Air Conditioning Unit>500 Btu/h III Gas Piping<or equal to 5 units Gas Piping for each additional unit> 5 Heat Exchangers Heat Pump-Condensing Unit Hot Water Heat Coils Miscellaneous Appliance - regulated by mechanical code, not otherwise specified Package Units< or equal to 100btu/> 100 Btu Range/Cook top-Gas Fired Refrigeration Unit < or equal to 100Btu/h Refrigeration Unit>100Btu/h Refrigeration Unit>500Btu/h Re-inspection fee Residential Range Hood Unit Heaters < or equal to 100 Btu/h Unit Heaters >100 Btu/h Variable Air Volume Boxes (part of air conditioning system) 1 Wall Heaters - Gas Fired Water Heater- Gas Fired 1 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulation of the State of Washington. Print Name: I Craig Mikes Date: 03/18/2026 4rtk( tot( WASHINGTON Permit Information - - , 1 'nformat;^ Permit# 26-0227 Parcel # 00928200003300 Building ID Location 19303 45TH DR NE Permit Type Residential Permit Use Mechanical Zone Permit # Subdivision Applicant Name Seatown Electric Plumbing Heating and Air, LLC Address 4200 78th St SW Applicant Email permits@seatownservices Phone 4252701627 Cell .com Owner Name Alexander Jasper Address 19303 45TH DR NE ARLINGTOIN, WA, 98223 Owner Email Ajasper408@gmail.com Phone Cell Contractor Seatown Services Address Contractor Email permits@seatownservices Phone Cell .com Property Information Type/Improveme Accessory/Struct nt ure Current Use Proposed Use Current Zoning 0 Proposed Zoning Project Cost 5000 Project Value 5000 Current Use And replace furnace Proposed Changes Lot Width Lot Depth Map Number Total Area of Building & Accessory Total Area of All Man-made Improvements Structures (Sq Ft) (Sq Ft) General Notes Restrictions/ Variances ©Community Development Online Portal Page 1 of 6 June 17, 2026 01:56PM WASHINGTON Structure Information Structure Type # of Stories Usable Floor Area (Sq Ft) Structure Height # of Units Load per Floor (Lbs) Sign Dimensions # of Bedrooms # of Bathrooms Occupancy With Chairs Tables & Chairs Empty Room Foundation Foundation Type Footing Depth Material Foundation Information Setbacks Front& 0 0 Setbacks Right & 0 0 Rear Left Sides Setbacks Information Water Utility Public Sewage Utility Public Gas Utility Public Electric Utility Public Driveway Width # of Off Street # of Off Street Parking Loading Miscellaneous Information ©Community Development Online Portal Page 2 of 6 June 17, 2026 01:56PM 4rtk( tot( WASHINGTON Contractors License# Business Name Type Contact SEATOEH767NZ SEATOWN ELECTRIC HEATING General Contractor Craig Mikes AND AIR, LLC ©Community Development Online Portal Page 3 of 6 June 17, 2026 01:56PM WASHINGTON Inspections Inspection # Inspection Type Status Date Inspector 26-0289 Residential - Mechanical Pass May 8, 2026 Brian Grieve Final ©Community Development Online Portal Page 4 of 6 June 17,2026 01:56PM 4rtk( tot( WASHINGTON Contacts Contact Name Type Project Address Phone Alexander Jasper Owner 19303 45TH DR NE ARLINGTOIN, WA, 98223 Seatown Electric Plumbing Others 4200 78th St SW 425-270-1627 Heating and Air, LLC Seatown Electric Plumbing Applicant 4200 78th St SW 425-270-1627 Heating and Air, LLC ©Community Development Online Portal Page 5 of 6 June 17, 2026 01:56PM 4rtk( tot( WASHINGTON Fees Fee Type Date Debit Credit Balance Permit Fees March 18, 2026 $150.00 $150.00 $150.00 $0.00 T O T A L $150.00 $150.00 $0.00 ©Community Development Online Portal Page 6 of 6 June 17, 2026 01:56PM WASHINGTON Permit #26-0227 Location:19303 45TH DR NE Routing Details ✓ Department: Permit Tech Intake Review - Approved: March 20, 2026 - Status: Approved Permit Application #A26-0227 Location:19303 45TH DR NE - by LaNay Hendrick- Permit Technician at March 18, 2026 04:05PM Status: In Progress Activity Type: Application Sent Hello, Looks like we are missing the spec sheets for the furnace for your application to be complete. You also indicated on the application that there would also be a water heater installed? Please let me know after you upload the needed documents and I will start the processing. LaNay Hendrick City of Arlington Permit Technician Ihendrick@arlingtonwa.gov 360-403-3437 Permit Application #A26-0227 Location:19303 45TH DR NE - by LaNay Hendrick- Permit Technician at March 19, 2026 02:13PM Status: Approved Activity Type: Application Sent LaNay Hendrick City of Arlington Permit Technician Ihendrick@arlingtonwa.gov 360-403-3437 Permit Application #A26-0227 Location:19303 45TH DR NE - by LaNay Hendrick- Permit Technician at March 19, 2026 02:13PM Status: In Progress Activity Type: Application Sent Hello, Your invoice is now ready for payment.You can access and process the payment through our portal. Please visit the following link to view and pay your invoice: https://www.civicgov4.com/wa_arlington/portal/index.php?r=site/dashboard Please let me know once you have made payment and I'll provide a copy of your issued permit and approved documents. LaNay Hendrick City of Arlington @ Community Development Online Portal Page 1 of 3 June 17, 2026 01:56PM 4rtk( tot( WASHINGTON Permit Technician Ihendrick@arlingtonwa.gov 360-403-3437 Permit #26-0227 Location:19303 45TH DR NE- by LaNay Hendrick- Permit Technician at March 20, 2026 08:43AM Status: Approved Activity Type: Application Sent Hello, Please find attached the issued building permit. Please review any conditions and reach out should you have any questions. Inspection request instructions can be found on the permit. LaNay Hendrick City of Arlington Permit Technician Ihendrick@arlingtonwa.gov 360-403-3437 ✓ Department: Permit Tech Final Approval - Approved: May 21, 2026 - Status: Closed Manual Approval - Permit#26-0015 Location:19303 45TH DR NE- by LaNay Hendrick- Permit Technician at March 20, 2026 08:42AM Status: Approved Activity Type: Documents Review The following permit has been approved manually. Permit#26-0015 Location:19303 45TH DR NE Manual Closure - Permit#26-0227 Location:19303 45TH DR NE - by Admin - Kristin Foster- Permit Technician II at May 21, 2026 11:43AM Status: Closed Activity Type: Documents Review The following permit has been closed manually. Permit#26-0227 Location:19303 45TH DR NE ©Community Development Online Portal Page 2 of 3 June 17, 2026 01:56PM WASHINGTON Record Actions New Permit Application #A26-0227 Location: 19303 45TH DR NE By LaNay Hendrick- Permit Technician at March 18, 2026 02:08PM Hello, A new permit application has been submitted for review. Please login to your CIVICGov Web Application account and visit the link below to view the permit details. https://www.civicgov4.com/wa_arlington/permits/details/355 If you cannot click on the link above, please copy and paste the entire link in the browser address bar. Sincerely, CIVICGov Team. Condition #1 Added By LaNay Hendrick- Permit Technician at March 20, 2026 08:39AM Condition: Adhere to approved mechanical equipment Condition #2 Added By LaNay Hendrick- Permit Technician at March 20, 2026 08:40AM Condition: Call for final inspection Condition #3 Added By LaNay Hendrick- Permit Technician at March 20, 2026 08:40AM Condition: Permit shall be onsite for inspection Manual Approval - Permit#26-0015 Location:19303 45TH DR NE By LaNay Hendrick- Permit Technician at March 20, 2026 08:42AM The following permit has been approved manually. Permit#26-0015 Location:19303 45TH DR NE Inspection #26-0289: Result- Pass By Kevin Olander- Building Official at May 13, 2026 03:29PM Residential - Mechanical Final Inspection #26-0289: Result- Pass 360-722-2270 and Ajasper408@gmail.com Manual Closure - Permit#26-0227 Location:19303 45TH DR NE By Admin - Kristin Foster- Permit Technician II at May 21, 2026 11:43AM The following permit has been closed manually. Permit#26-0227 Location:19303 45TH DR NE @ Community Development Online Portal Page 3 of 3 June 17, 2026 01:56PM