Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20500 Olympic Pl_BLD5421_2026
RE-ROOF PERMIT APPLICATION I Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Plione(360)403-3551 Type of Permit: Commercial ❑ Residential Property Address: 20500 Olympic Place Suite/Unit Number: Lot#: Parcel ID No.: 00847300000800 Project Valuation: 377,648.00 Project Scope of Work: Install flute fill, cover board, and new single ply membrane over existing metal roof. Primary Contact: ❑ Owner ❑ Applicant © Contractor Owner Name: ACI Real Estate Company LLC. Office No.: 480-682-8196 Email Address: Cell No.: Mailing Address: 5918 Stoneridge Mall Road City: Pleasanton State: CA Zip:94588 Applicant Name: Nations Roof Mountain, LLC. Office No.: 208-322-2474 Email Address: jwilliams@ nationsroof.com Cell No.: 208-740-76 Mailing Address: 10621 W. Executive Dr. City:Boise State: ID Zip: 83713 Contractor Name: Nations Roof Mountain, LLC. Office No.: 208-322-2474 Email Address: jwilliams@ nationsroof.com Cell No.: 208-740-7628 Mailing Address: 10621 W. Executive Dr. City: Boise State: ID Zip: 83713 L&1 Contractor License Number: NAl10RM828P6 Expiration Date: 12/10/2023 Type of Roofing Material: PVC Replacing existing sheathing: ❑Yes J?J No Nruuber of Existing Layers: 1 Installation over existing material: W Yes ❑No Roof tear off. ❑Yes Q No Class of Roofing: I;d A-Highest Fire Rating ❑ B- Moderate Fire Rating ❑C- Light Fire Rating ---------------------------- ----------------------------------------------------------- ------------------------------------------------- -------------------------------------------- Class Examples: Concrete,Clay,Roof Tiles,Fiberglass Pressured Treated Shakes and Untreated Wood Shakes and Asphalt Composition Shingles,Metal Roofs Shingles Shingles,Plywood,Particleboard The following is required for NON-RESIDENTIAL BUILDINGS Provide 2 copies of the installation specifications and U.L.listed roof assembly. Existing RoofStnicture: Metal Existing Roof Material: Metal Building Occupancy: ❑Office/Professional Services El Industrial El Restaurant ❑Other: ❑Educational Facility Retail ❑Religious Facility I hereby certify that 1 arri the ❑ Owner, ❑Applicant, 2 Contractor, and authorized to sign this application and that the above information is correct and constr•rrction oil, and the occupancy and the Use of the above-described property will be ill accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when th tic, cornplete. Z' Signatt fe Print Name to FOR STAFF USE ONLY PERMIT tt ACCEPTED BY: DATE STAMP ItHNO 1.2022 EMISSION insuL PREDICTABLY CONSISTENT VALUE. ACI■ ■ INSULATION SYSTEMSEeap Hra A Assemblies > Insulfoam EPS insulations come with numerous c o na ona an regi na > UL Class A ratings automatically provide UL Class Band UL Class C ratings > The UL listings shown below are a sample of our approvals for common roof systems > Coverboards,where needed,are available from Insulfoam as composite products Check with your local Insulfoam rep for a complete listing of approvals and ratings applicable to your region (EPS factory-bonded to Gyp,OSB or Plywood)or can also be field applied DECK STEEL CONCRETE WOOD/COMBUSTIBLE Membrane Fully Adhered Mechanically Attached Ballasted Fully Adhered Mechanically Ballasted Fully Adhered Mechanically Ballasted Attached Attached Insulfoam® UL Class A UL Class A with slipsheet or UL Class A UL Class A UL Class A with UL Class A UL Class A with min. UL Class A with min. UL Class A (Flat EPS roof insulation panels) with coverboard coverboard with coverboard slipsheet or 1/4"gyp coverboard 1/4"gyp coverboard coverboard Tapered InsulFoam UL Class A UL Class A with slipsheet or UL Class A UL Class A UL Class A with UL Class A UL Class A with min. UL Class A with min. UL Class A (Tapered EPS roof insulation- with coverboard coverboard with coverboard slipsheet or 1/4"gyp coverboard 1/4"gyp coverboard various densities&sizes) Icoverboard InsulFoam HB UL Class A with LWC systems UL Class A with LWC systems UL Class A with LWC systems (Flat EPS with 6 or 8 factory-applied holes, for lightweight concrete systems) R-Tech®FF Not Applicable Retains existing UL Classification I Not Applicable Retains existing UL Classification Not Applicable Retains existing UL Classification (Flat EPS fanfold roof underlayment with polymeric white&metalized facers; 2 square bundles) R-Tech Not Applicable Retains existing UL Classification Not Applicable Retains existing UL Classification Not Applicable Retains existing UL Classification (Flat EPS roof underlayment with polymeric white&metalized facers;4'x 8'panels) InsulFoam SP • Single-ply UL Class A UL Class A • Single-ply UL Class A UL Class A Not Applicable Not Applicable UL Class A (Fire Rated System: membrane with membrane with Flat EPS with coated glass facer) EPS-compatible EPS-compatible adhesive adhesive • Peel&stick • Peel&stick membranes membranes (max.60 mil) (max.60 mil) InsulFoam HD Composite UL Class A UL Class A UL Class A UL Class A UL Class A UL Class A UL Class A with min. UL Class A with min. UL Class A (Flat EPS factory-bonded to 11/2"Ahick 41/2"thickness 41/2"thickness with min.4%2" 100 psi high-density polyiso) thickness InsulFoam FL UL Class A • UL Class A with coverboard UL Class A Not Applicable Not Applicable Not Not Applicable Not Applicable Not Applicable (InsulFoam EPS custom-cut to fill with coverboard • No coverboard when Applicable metal roof flutes) combined with InsulRoof SP InsulLam"or InsulVenf' UL Class A UL Class A UL Class A UL Class A UL Class A UL Class A UL Class A with min. UL Class A with min. UL Class A (Flat EPS factory-bonded to Gyp,OSB,plywood) 1/4"gyp coverboard 1/4"gyp coverboard 19727 57t'Avenue East m Puyallup,WA 98375 m Toll Free: :00 o. ESICC Most Videly Accepted and Trusted ICC-ES Evaluation Report ESR-1157 Reissued September 2019 This report is subject to renewal September 2021. wwwJcc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE 3.2 Materials: PROTECTION 3.2.1 Sarnafil S327 Single-Ply Membrane: The Sarnafil Section: 07 54 00—Thermoplastic Membrane Roofing S327 membrane is a polyester reinforced PVC membrane Section: 07 54 19—Polyvinyl-Chloride Roofing complying with ASTM D4434 as Type III, and available REPORT HOLDER: with or without a factory-applied felt backing. The Sarnafil S327 is manufactured in four thicknesses. See Table 4 for SIKA SARNAFIL, INC. thicknesses and weights of the membranes with and without the felt backing.The membrane is reinforced with a EVALUATION SUBJECT: polyester scrim. Sarnafil S327 is intended for installation over foam plastic insulation when attached with SARNAFIL S327, G410, G410 SAM, SIKAPLAN mechanical fasteners described in Section 3.2.9 and FASTENED AND SIKAPLAN ADHERED SINGLE-PLY Table 2. ROOFING SYSTEMS 3.2.2 Sarnafil S327 Textured Single-Ply Membrane: The Sarnafil S327 Textured membrane is a polyester 1.0 EVALUATION SCOPE reinforced PVC membrane complying with ASTM D4434 Compliance with the following codes: as Type III. The textured surface is the weather surface. The Sarnafil S327 Textured membrane is manufactured in ■ 2018, 2015, 2012, 2009 and 2006 International Building three thicknesses. See Table 4 for thicknesses and Code®(IBC) weights of the membranes. The membrane is reinforced ■ 2018, 2015, 2012, 2009 and 2006 International with a polyester scrim. Sarnafil S327 Textured membrane Residential Code®(I RC) is intended for installation over foam plastic insulation when attached with mechanical fasteners described in Properties evaluated: Section 3.2.9 and Table 2. ■ Weather resistance 3.2.3 Sarnafil G410 Single-Ply Membrane: The Sarnafil ■ Wind uplift resistance G410 membrane, typically used in adhered systems, is a glass fiber—reinforced PVC membrane complying with ■ Roof covering fire classification ASTM D4434 as Type II, and is available with or without ■ Impact resistance factory-applied felt backing. The Sarnafil G410 is manufactured in four thicknesses. See Table 4 for 2.0 USES thicknesses and weights of the membranes with and The Sarnafil S327, G410, G410 SA, Sikaplan Fastened without the felt backing. The fiberglass reinforcement is and Sikaplan Adhered Single-Ply Roofing Systems are arranged in a woven mat. Sarnafil G410 is intended for used as classified roof covering assemblies. installation over insulation when fully adhered to the substrate using proprietary adhesives as described in 3.0 DESCRIPTION Section 3.2.10 and Table 3. 3.1 General: 3.2.4 Sarnafil G410 Textured Single-Ply Membrane: The Sarnafil Single-Ply Roofing Systems consist of single- The Sarnafil G410 Textured membrane, typically used in ply reinforced thermoplastic membranes constructed with adhered systems, is a glass fiber-reinforced PVC reinforced poly (vinyl chloride) (PVC). The systems can be membrane complying with ASTM D4434 as Type II. The installed over various types of roof decking, including textured surface is the weather surface. The Sarnafil G410 wood, steel and concrete surfaces. The systems are either Textured membrane is manufactured in three thicknesses. adhered, mechanically fastened or a combination of See Table 4 for thicknesses and weights of the mechanically fastened and adhered to resist wind uplift. membranes. The fiberglass reinforcement is arranged in a Sarnafil membranes are manufactured in rolls 3.25, 5, 6.5 woven mat. Sarnafil G410 Textured membrane is intended and 10 feet wide (914, 1520, 1980 and 3050 mm) with for installation over insulation when fully adhered to the lengths from 65.6 to 100 feet (20 to 30.5 m). The substrate using proprietary adhesives as described in membranes are typically manufactured with a white Section 3.2.10 and Table 3. weathering surface and a grey underside. However, 3.2.5 Sarnafil G410 SAM Single-Ply Membrane: The custom pigments are available upon request. Sarnafil G410 SAM, used in adhered systems, is a fiber- 1CC-ES Evaluation Reports are not to be construed as representing aesthetics or•any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty kv ICC Evaluation Service,LLC,express or implied,as il. to any finding or other matter in this report,or as to any product covered by the report. !! Copyright©2019 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 10 ESR-1157 [ Most Widely Accepted and Trusted Page 2 of 10 reinforced PVC membrane complying with ASTM D4434 insulation) to combustible or noncombustible roof decks. as Type II. The Sarnafil G410 SAM is manufactured in The Sikaplan Fastener #14 has a shank diameter of three thicknesses. See Table 4 for thickness and weights 0.190 inch (4.8 mm) and thread diameter of 0.245 inch of the membranes. The fiberglass reinforcement is (6.2 mm). arranged in a woven mat. The membrane has a pressure 3.2.9.4 Sarnafastener XP: The Sarnafastener XP is used sensitive adhesive backing with a release liner. Sarnafil with the Sarnadisc, described in Section 3.2.9.7, to attach G410 SAM is intended for installation over insulation fully insulation, and with the Sarnadisc XPN, described in adhered to the substrate as described in Table 3. Section 3.2.9.9, or the Sarnarail Polymer Batten, described 3.2.6 Sikaplan Fastened Single-Ply Membrane: The in Section 3.2.9.12, to attach the membrane (through the Sikaplan Fastened membrane is a polyester reinforced insulation) to combustible or noncombustible roof decks. PVC membrane complying with ASTM D4434 as Type III, The Sarnafastener XP has a shank diameter of 0.21 inch and available with or without a factory-applied felt backing. (5.3 mm)and thread diameter of 0.26 inch (6.6 mm). The Sikaplan Fastened membrane is manufactured in two 3.2.9.5 Sarnafastener MAXLoad: The Sarnafastener thicknesses. See Table 4 for thicknesses and weights of MAXLoad is used to attach the Sarnafil membrane with the the membranes with and without the felt backing. The Sarnadisc MAXLoad, described in Section 3.2.9.10, or membrane is reinforced with a polyester scrim. Sikaplan Sarnarail Polymer Batten, described in Section 3.2.9.12, to Fastened is intended for installation over foam plastic steel or combustible decks. The Sarnafastener MAXLoad insulation as indicated in Table 1 when attached with has a shank diameter of 0.26 inch (6.6 mm) and a thread mechanical fasteners described in Section 3.2.9 and diameter of 0.33 inch (8.4 mm). Table 2. 3.2.9.6 Sarnaplate: The Sarnaplate is a 3-by-3-inch 3.2.7 Sikaplan Adhered Single-Ply Membrane: The (76 mm by 76 mm), No. 26 gage [0.018 to 0.021 inch Sikaplan Adhered membrane, typically used in adhered (0.45 to 0.53 mm) base-metal thickness], AZ 55 systems, is a glass fiber-reinforced PVC membrane Galvalume-coated plate. complying with ASTM D4434 as Type II, and is available with or without factory-applied felt backing. The Sikaplan 3.2.9.7 Sarnadisc: The Sarnadisc is a 3-inch-diameter Adhered membranes are manufactured in two (76 mm), No. 26 gage [0.018 to 0.021 inch (0.45 to thicknesses. See Table 4 for thicknesses and weights of 0.53 mm) base-metal thickness], AZ 55 Galvalume-coated the membranes with and without the felt backing. The plate. fiberglass reinforcement is arranged in a woven mat. 3.2.9.8 Sarnadisc 23/8: Sarnadisc 23/8 is 23/8-inch Sikaplan Adhered is intended for installation over (60 mm) diameter, 0.037-inch (0.94 mm) thick plate insulation that is attached to roof decks as indicated in stamped from Galvalume AZ 50 or AZ 55 steel. It has six Table 1 when fully adhered to the substrate using equally spaced "v" protrusions punched through proprietary adhesives as described in Section 3.2.10 and concentrically at 19/32-inch (15 mm) from the center of the Table 3. plate. 3.2.8 Foam Plastic Insulation: Foam plastic insulation, 3.2.9.9 Sarnadisc XPN: The Sarnadisc XPN is a 11/2-by- where used, must have a flame-spread index of not greater 33/4-inch (38 by 95 mm), No. 18 gage [0.040 to 0.042 inch than 75 when tested, at the maximum thickness intended (1.00 tol.05 mm)base-metal thickness],AZ 55 Galvalume- for use, in accordance with ASTM E84 or UL 723. See coated plate. Tables 1, 2 and 3 for insulations recognized for use with the respective roofing systems. 3.2.9.10 Sarnadisc MAXLoad: The Sarnadisc MAXLoad is a 3.5-inch-diameter (89 mm), No. 20 gage [0.031 to 3.2.9 Mechanical Fasteners: Substrate, fastener and 0.041 inch (0.78 to 1.02 mm)base-metal thickness], AZ 55 plate combinations must be as outlined in the Galvalume-coated plate. manufacturer's published installation instructions and Table 2 of this report. 3.2.9.11 Sarnadisc RhinoBond: Sarnadisc RhinoBond is a 3-inch (75 mm) diameter, 0.028-inch (0.7 mm) thick 3.2.9.1 Sarnafastener #12: The Sarnafastener #12 is metal plate coated with a polymer coating used in used with the Sarnaplate, described in Section 3.2.9.6, to conjunction with the RhinoBond induction welder to attach attach insulation boards to steel or combustible roof decks. the membrane. Sarnafastener#12 has a modified buttress thread, a shank diameter of 0.168 inch (4.3 mm) and a thread diameter of 3.2.9.12 Sarnarail Polymer Batten: The Sarnarail 0.214 inch (5.4 mm). Polymer Batten is a 1-inch-wide-by-250-foot-long-by-1/2o- inch-thick(25 mm by 762 m by 1.27 mm)modified polymer 3.2.9.2 Sarnafastener #14: The Sarnafastener #14 is batten. The batten, manufactured in coils, has holes used with the Sarnaplate, described in Section 3.2.9.6, to spaced 6 inches (152 mm) on center and is used with attach insulation, and with the Sarnadisc XPN, described in either the Sarnafastener XP or the MAXLoad fasteners, Section 3.2.9.9, or the Sarnadisc RhinoBond, described in described in Sections 3.2.9.4 or 3.2.9.5, respectively, for Section 3.2.9.11, or the Sarnarail Polymer Batten, securing the roof membrane. described in Section 3.2.9.12 to attach the membrane 3.2.10 Adhesives: (through the insulation) to combustible or noncombustible roof decks. The Sarnafastener#14 has a shank diameter 3.2.10.1 Sarnacol 2170: Sarnacol 2170 is a solvent-based of 0.190 inch (4.8 mm) and thread diameter of 0.245 inch adhesive for bonding Sarnafil membranes to foam plastic (6.2 mm). substrates or Georgia-Pacific LLC DensDeck Roofboard 3.2.9.3 Sikaplan Fastener #14: The Sikaplan Fastener with application rates as specified in Table 3. Sarnacol #14 is used with the Sarnaplate, described in Section 2170 is supplied in 5-gallon (18.9 L) steel containers. The 3.2.9.6, to attach insulation, and with the Sarnadisc 23/8, shelf life is one year when the adhesive is stored in the described in Section 3.2.9.8, Sarnadisc XPN, described in original unopened container at temperatures between 40°F Section 3.2.9.9, Sarnadisc RhinoBond, described in and 80°F(4.4°C and 26.7°C). Section 3.2.9.11, or Sarnarail Polymer Batten, described 3.2.10.2Sarnacol 2170 VC: Sarnacol 2170 VC is a in Section 3.2.9.12, to attach the membrane (through the solvent-based adhesive used for bonding Sarnafil ESR-1157 1 Most Widely Accepted and Trusted Page 3 of 10 membranes to foam plastic substrates or Georgia-Pacific systems. The systems must be installed at the maximum LLC DensDeck® Roof Board with application rates as slope specified in Table 1. specified in Table 3. Sarnocol 2170 VC is supplied in 4.3 Wind Resistance: 5-gallon (18.9 L)steel containers. The shelf life is one year when the adhesive is stored in the original unopened See Tables 2 and 3 for a full description of components, container at temperatures between 40°F and 80°F (4.4°C fastener spacing, adhesive application and allowable and 26.7°C). design wind uplift pressures for each of the evaluated 3.2.10.3 Sarnacol 2121: Sarnacol 2121 is a water-based systems. adhesive for bonding Sarnafil membranes to foam plastic 4.3.1 Metal Edge Securement Systems: Metal edge substrates or Georgia-Pacific LLC DensDeck® Roof Board securement systems must be listed in accordance with the with application rates as specified in Table 3. Sarnacol 2011 edition of ANSI/SPRI/FM 4435 ES-1, and designed 2121 is supplied in 5-gallon (18.9 L) steel containers. The and installed for wind loads in accordance with 2018 and shelf life is one year when the adhesive is stored in the 2015 IBC Section 1504.5 and 2018 and 2015 IBC Chapter original unopened container at temperatures between 40°F 16 [2003 edition of ANSI/SPRI/FM 4435 ES-1, and and 80°F(4.4°C and 26.7°C). designed and installed for wind loads in accordance with 3.2.10.4 Sarnacol AD Feltback Membrane Adhesive: 2012, 2009 and 2006 IBC Section 1504.5 and 2012, 2009 Sarnacol AD Adhesive is a two-part liquid applied non- and 2006 IBC Chapter 161. asphaltic urethane adhesive that transforms into a low rise 4.4 Flashing: foam during the curing process. The adhesive is packaged Flashing must be provided as required by IBC Section in 0.16-gallon (600 mL) cartridges, four to a box or 1503.2.1 or IRC Section R903.2.1, as applicable. Where 10-gallon (37.8 L) box sets consisting of two parts: (Part 1 flashing is of metal, the metal must be corrosion-resistant - 5-gallon (18.9 L) and Part 2 - 5-gallon (18.9 L)). The with a thickness of not less than No. 26 gage [base-metal shelf life is 18 months when the adhesive is stored in the thickness of 0.019 inch(0.5 mm)]. original unopened container at temperatures between 45°F and 95°F(7°C and 35°C). 4.5 Reroofing: 3.2.10.5 Sarnacol OM Feltback Membrane Adhesive: The existing deck must be inspected to verify that the Sarnacol OM Adhesive is a two-part low rise polyurethane structure to be reroofed is structurally sound and adequate adhesive that is applied in one step, dispensed at a 1:1 to support and secure the roofing membrane. Prior to ratio. The adhesive is packaged in 0.16-gallon (600 mL) installation of new roof coverings, inspection by, and cartridges, four to a box or 10-gallon (37.8 L) box sets written approval from, the code official having jurisdiction consisting of two parts: (Part 1 -5-gallon (18.9 L)and Part are required in accordance with 2018 and 2015 IBC 2-5-gallon (18.9 L)). The shelf life is 18 months when the Section 1511 [2012, 2009 and 2006 IBC Section 1510]. adhesive is stored in the original unopened container at The roof covering systems described in this report, temperatures between 557 and 85°F (12.8°C and installed over an existing roof covering system, must be 29.5-C). shown to satisfy classification requirements by testing of the composite system in accordance with ASTM E108 or 3.2.11 Barrier Board: Barrier board, where used, must be UL 790. As an alternative, Class A, B or C roof covering a minimum of 1/4-inch (6.4 mm) DensDeck® Roof Board systems are permitted to be installed over existing manufactured by Georgia-Pacific LLC classified roof covering systems under the following 3.3 Impact Resistance: conditions without additional roof classification tests, provided the resulting classification is the lower of the The Sarnafil S327 and G410 Single-Ply Roofing Systems classification for the new and existing roofing: described in this report comply with the requirements for impact resistance in accordance with Section 4.6 of • New uninsulated systems installed only over existing FM 4470. uninsulated assemblies. 4.0 INSTALLATION • New insulated systems installed only over existing 4.1 General: uninsulated system Installation of the Sarnafil S327, G410, G410 SAM, 5.0 WWI S OF USE Sikaplan Fastened and Sikaplan Adhered Single-Ply The Sarnafil S327, G410, G410 SAM, Sikaplan Fastened Roofing Systems must comply with the applicable code, and Sikaplan Adhered Single-Ply Roofing Systems this report and the manufacturer's published installation described in this report comply with, or are suitable instructions. The manufacturer's published installation alternatives to what is specified in, the codes indicated in instructions must be available at the jobsite at all times Section 1.0 of this report, subject to the following during installation. The substrate must be smooth, dry, conditions: clean and free of sharp projections, loose fasteners, 5.1 Installation must comply with this report, the protrusions, depressions or contaminants that might manufacturer's published instructions and the interfere with the adhesion or attachment of the applicable code. If there is a conflict between the membrane. Any surface defects must be corrected prior to manufacturer's published installation instructions and the membrane installation. All materials must be protected this report,this report governs. against contact with incompatible materials. The roof systems must not be installed on roofs having slopes less 5.2 The Sarnafil S327, G410, G410 SAM, Sikaplan than '/4:12 (2 percent slope)or more than that specified for Fastened and Sikaplan Adhered Single-Ply Roofing the particular assembly as listed in Table 1 for the Systems must be installed by a Sarnafil, Inc., trained corresponding assembly and roof classification. and approved contractor. Evidence of this approval must be made available to the code official upon 4.2 Roof Covering Classification: request. See Table 1 for a full description of components and the 5.3 Design wind uplift pressures on any roof area, roof covering classification for each of the evaluated including edge and corner zones, must not exceed BUILDING TRUST PRODUCT DATA SHEET SikaplanO Fastened -60 EnergySmart 60 mil thick PVC thermoplastic membrane PRODUCT DESCRIPTION CHARACTERISTICS / ADVANTAGES Sikaplan° Fastened-60 EnergySmart Roof Membrane is a \ PVC thermoplastic membrane produced with a polyester scrim reinforcement. USES "WAWAFrRoof Mechanically attached using various attachment Highly reflective components over approved substrates. It may also be Excellent tear strength resistance used in adhered applications to approved substrates. Factory applied lacquer coating to reduce dirt pick up • Hot-air welded seams for long-term performance AREAS OF APPLICATION APPROVALS / STANDARDS • In-seam disc systems • In-seam batten, double-weld systems FM Global' • RhinoBond' systems Underwriters Laboratories • Adhered systems Underwriters Laboratories of Canada • New construction and reroofing ICC Code Compliance—ESR 1157 • Miami-Dade County • Florida Building Code • California Title 24 • LEED/Green Globes 'Mechanically attached only. Product Data Sheet Sikaplan®Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 1/4 PRODUCT INFORMATION Chemical Base Thermoplastic PVC membrane containing ultraviolet light stabilizers,flame retardant and polyester scrim reinforcement with a unique lacquer coating on the top surface. Recycled Content 9%Pre-consumer, 1%Post-consumer Reinforcing Material Polyester Packaging 60 mil(1.5 mm)Membrane 10 ft x 100 ft(3 m x 30 m) roll,343 Ibs(156 kg) per roll, 8 rolls per pallet 5 ft x 100 ft(1.5 m x 30 m) roll, 172 Ibs(78 kg) per roll, 12 rolls per pallet Shelf Life N/A Storage Conditions Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability. Appearance/Color • Top:White, Reflective Gray,and Tan • Bottom:Gray Overall Thickness 60 mil (1.5 mm), nominal (ASTM D-751) 45 mil (ASTM Type III D-4434 Spec.Requirement) Thickness Above Scrim 24 mil (ASTM D-7635) 16 mil (ASTM Type III D-4434 Spec. Requirement) TECHNICAL INFORMATION Resistance to Static Puncture Pass (ASTM D-5602) 33 Ibf(15 kg) (ASTM Type III D-4434 Spec.Requirement) Resistance to Dynamic Puncture Pass (ASTM D-5635) 14.7 ft-Ibf(20 J) (ASTM Type III D-4434 Spec. Requirement) Tensile Strength 303 Ibf(1348 N) (ASTM D-751) 200 Ibf(890 N) (ASTM Type III D-4434 Spec. Requirement) Elongation at Break 20&20%MD&CMD1 (ASTM D-751) 15& 15%MD&CMD1 (ASTM Type III D-4434 Spec. Requirement) 1 MD=Machine Direction,CMD=Cross Machine Direction. Tear Strength 45 Ibf(200 N) (ASTM D-751) 45 Ibf(200 N) (ASTM Type III D-4434 Spec.Requirement) Seam Strength Pass (ASTM D-751) 75%of origina12 (ASTM Type III D-4434 Spec. Requirement) z Failure occurs through membrane rupture not seam failure. Linear Dimensional Change 0.24% (ASTM D-1204) 0.5% (ASTM Type III D-4434 Spec. Requirement) Product Data Sheet Sikaplan®Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 BUILDING TRUST 2/4 Solar Reflectance EnergySmart Colors Initial Solar 3-Year Solar Reflectance' Reflectance, EnergySmart 0.85 0.75 White EnergySmart 0.73 0.66 Reflective Gray EnergySmart 0.72 0.65 Tan 1 Solar Reflectance testing according to ASTM C-1549. Solar Reflectance Index EnergySmart Colors Initial Solar 3-Year Solar Reflectance Index' Reflectance Index' EnergySmart 107 93 White EnergySmart 90 80 Reflective Gray EnergySmart 88 78 Tan 1 Solar Reflectance Index calculated according to ASTM E-1980. Thermal Emittance EnergySmart Colors Initial Thermal 3-Year Thermal Emittance, Emittancel EnergySmart 0.89 0.90 White EnergySmart 0.89 0.88 Reflective Gray EnergySmart 0.89 0.88 Tan 1 Thermal Emittance testing according to ASTM C-1371,Slide Method. Low Temperature Bend Pass (ASTIVI D-2136) Pass-40°F(-40°C) (ASTM Type III D-4434 Spec.Requirement) Weight Change after Immersion in Water 2.5% (ASTM D-570) +3,0% (ASTM Type III D-4434 Spec. Requirement) UV Exposure 10,000 hours (ASTM G-154) 5,000 hours (ASTM Type III D-4434 Spec. Requirement) Cracking None (7x magnification) Discoloration Negligible (by observation) Crazing None (7x magnification) Retention of Properties after Heat Ageing Tensile Strength,%of original: Pass (ASTM D-3045) Elongation,%of original: Pass (ASTM D-751) Tensile Strength,%of original:90 (ASTM Type III D-4434 Spec. Requirement) Elongation,%of original:90 BASIS OF PRODUCT DATA AVAILABILITY/WARRANTY Results may differ based upon statistical variations AVAILABILITY depending upon mixing methods and equipment, temperature,application methods,test methods,actual From Sika Corporation—Roofing Authorized Applicators site conditions and curing conditions. for use within Sarnafil or Sikaplan systems. Product Data Sheet Sikaplan®Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 BUILDING TRUST 3/4 LEGAL DISCLAIMER WARRANTY • KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN Upon successful completion of the installed roof by the . NOT FOR INTERNAL CONSUMPTION Sika Authorized Applicator in compliance with Sika • FOR INDUSTRIAL USE ONLY requirements,Sika Corporation will provide a warranty . FOR PROFESSIONAL USE ONLY to the Building Owner via the Sika Authorized Applicator. ENVIRONMENTAL HEALTH AND SAFETY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates("SIKA"),the user must always read and follow the warnings and instructions on the For further information and advice regarding product's most current product label, Product Data transportation, handling,storage and disposal of Sheet and Safety Data Sheet which are available at chemical products, user should refer to the actual Safety usa.sika.com or by calling SIKA's Technical Service Data Sheets containing physical,environmental, Department at 1-800-933-7452. Nothing contained in toxicological and other safety related data. User must any SIKA literature or materials relieves the user of the read the current actual Safety Data Sheets before using obligation to read and follow the warnings and any products. In case of an emergency,call CHEMTREC instructions for each SIKA product as set forth in the at 1-800-424-9300, International 703-527-3887. current product label, Product Data Sheet and Safety APPLICATION INSTRUCTIONS Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of APPLICATION installation to be free from manufacturing defects and to meet the technical properties on the current Product Sikaplan Fastened is installed on acceptable substrates Data Sheet if used as directed within the product's shelf and fastened to the roof deck using the approved life. User determines suitability of product for intended attachment method. In adhered applications,the use and assumes all risks. User's and/or buyer's sole membrane is unrolled into approved Sikaplan or Sarnacol adhesive in accordance with Sika's technical remedy shall be limited to the purchase price orreplacement of this product exclusive of any labor costs. requirements and then pressed into place with a NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL minimum 75 lb(34 kg)steel roller.The membrane is APPLY INCLUDING ANY WARRANTY OF heat-welded together by trained mechanics using hot-air MERCHANTABILITY OR FITNESS FOR A PARTICULAR welding equipment.Sikaplan Fastened can be used for PURPOSE.SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL fleshings on Sikaplan Fastened and Sikaplan Adhered THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. roof projects. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS MAINTENANCE PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD Standard maintenance of Sikaplan systems should BY OTHERS. include regular inspections of flashings,drains and Sale of SIKA products are subject to the Terms and terminations sealants at least twice a year and after Conditions of Sale which are available at each storm. https://usa.sika.com/en/group/SikaCorp/termsandconditions.html OTHER RESTRICTIONS or by calling 1-800-933-7452. See Legal Disclaimer. Sika Corporation 201 Polito Avenue Lyndhurst,NJ 07071 Phone:+1-800-933-7452 Fax:+1-201-933-6225 usa.sika.com SikaplanFastened-60EnergySmart-en-US-(09-2022)-7-1.pdf Product Data Sheet Sikaplan®Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 4/4 BUILDING TRUST SikaplanO MechanicallymAttached Sika Corporation - Roofing 100 Dan Road, Canton MA 02021 (800) 451-2504 usa.sika.com/sarnafil Samafil@ BUILDING TRUST Sika Corporation -Roofin_p Specification Sikaplan Mechanically-Attached PART 1 - GENERAL CONDITIONS 1.01 DESCRIPTION A. Scope To install a complete Sikaplan mechanically-attached system including membrane, flashings and other components. B. Related Work The work includes but is not limited to the installation of: 1. Substrate preparation 2. Roof membrane 3. Fasteners 4. Adhesive for flashings 5. Roof membrane flashings 6. Walkways 7. Metal Flashings 8. Sealants C. Upon successful completion of work the following warranties may be obtained: 1. Sika Corporation Warranty 2. Roofing Applicator Warranty 1.02 QUALITY ASSURANCE A. This roofing system shall be applied only by a roofing applicator authorized prior to bid by Sika Corporation (Sika Corporation "Applicator"). B. A Sika Corporation Technical Service Representative will review the installed roof system wherever a System Warranty has been requested. C. All work pertaining to the installation of membrane, flashings, and accessories shall only be completed by Applicator authorized by Sika Corporation in those procedures. D. Roofing membrane manufacturer must have a demonstrated performance history of producing PVC roof membranes no less, in duration of years, than the warranty duration specified. E. Roofing membrane and membrane flashings to be manufactured by membrane supplier and not private labeled. F. Manufacturer to have a minimum ten years of experience recycling their membranes at the end of their service life back into new membrane products. Provide a minimum of five reference projects completed with new membrane produced from recycled membrane. G. Applicable code/insurance requirements shall be identified by the Owner or Owner's representative. 1.03 SUBMITTALS A. At the time of bidding, the Applicator shall submit to the Owner(or Representative)the following: A. Written approval by the insulation manufacturer(as applicable) for use of the product in the proposed system. February 2023 1 Sika Corporation -Roofin_g Specification Sikaplan Mechanically-Attached 1.04 PRODUCT DELIVERY, STORAGE, AND HANDLING A. All products delivered to the job site shall be in the original unopened containers or wrappings bearing all seals and approvals. B. Handle all materials to prevent damage. Place all materials on pallets and fully protect from moisture. C. Membrane rolls shall be stored lying down on pallets and fully protected from the weather with clean tarpaulins. Unvented tarpaulins are not accepted due to the potential accumulation of moisture beneath the tarpaulin which may affect the membrane weldability. D. As a general rule all adhesives shall be stored at temperatures between 40°F (4°C) and 80°F (27°C). Read product data sheets and instructions contained on adhesive canisters for specific storage instructions. E. All flammable materials shall be stored in a cool, dry area away from sparks and open flames. Follow precautions outlined on containers and read product Safety Data Sheets (SDS). F. Any materials which the Owner's representative or Sika Corporation determine to be damaged are to be removed from the job site and replaced at no cost to the Owner. G. Safety Data Sheets (SDS) shall be available at the job site at all times. 1.05 JOB CONDITIONS A. Only as much of the new roofing as can be made weathertight each day, including all flashing and detail work, shall be installed. All seams shall be heat welded before leaving the job site that day. B. Temporary overnight tie-ins shall be installed at the end of each day's work and shall be completely removed (including any contaminated materials) before proceeding with the next day's work. C. The Applicator shall follow all safety regulations as required by OSHA and any other applicable authority having jurisdiction. Roof and walkways may be slippery when icy, snow covered, or wet. Working on surfaces under these conditions is hazardous.Appropriate safety measures must be implemented prior to working on such surfaces. Always follow OSHA and other relevant fall protection standards when working on roofs. D. Where applicable, the Applicator shall arrange for pullout tests in accordance with the latest versions of the SPRI/ANSI Standard Field Test Procedures FX-1 and IA-1 for fasteners and adhesives, respectively, to verify condition of the deck/substrate and to confirm expected pullout values. E. The Sikaplan membrane shall not be installed under the following conditions without consulting Sika Corporation's Technical Dept. for precautionary steps: 1. The roof assembly permits interior air to pressurize the membrane underside. 2. Any exterior wall has 10% or more of the surface area comprised of opening doors or windows. 3. The wall/deck intersection permits air entry into the wall flashing area. F. Special consideration should be given to construction related moisture. Sika Corporation is not responsible for damage when exposed to construction related moisture. February 2023 2 Sika Corporation -Roofin_p Specification Sikaplan Mechanically-Attached 1.06 WARRANTIES A. Sika Corporation Warranty Upon successful completion of the work to Sika Corporation's satisfaction and receipt of final payment, the Sika Corporation Warranty shall be issued. ARE COVERED UNDER SYSTEM WARRANTY.] 1.01 System Warranty B. Contractor Warranty 1.02 WARRANTY DURATIONS A. Sika Corporation's warranty shall be in effect for a 20 year duration. PART 2 - PRODUCTS 2.01 GENERAL A. Components of the roof system shall be products of Sika Corporation as indicated on the Detail Drawings and specified in the Contract Documents. B. Components that are other than those supplied or manufactured by Sika Corporation may be submitted for review and acceptance by Sika Corporation. Sika Corporation's acceptance of any other product is only for a determination of compatibility with Sika Corporation products and not for inclusion in the Sika Corporation warranty. The specifications, installation instructions, limitations, and restrictions of the respective manufacturers must be reviewed by the Owner's Representative for acceptability for the intended use with Sika Corporation products.. 2.02 MEMBRANE A. Membrane shall conform to: 1. ASTM D-4434 (latest version), "Standard for Polyvinyl Chloride Sheet Roofing". Classification: Type III. B. Sikaplan PVC thermoplastic membrane 1. Type of Membrane a) Sikaplan Fastened 2. Membrane Thickness a) 60 mil (1.5 mm) C. Color of Membrane 1. Sikaplan Fastened a) EnergySmart White D. Typical Physical Properties 1. Refer to individual Sikaplan Fastened Product Data Sheets for physical property values. February 2023 3 Sika Corporation -Roofin_a Specification Sikaplan Mechanically-Attached 2.03 ATTACHMENT COMPONENTS A. Membrane Attachment Discs 1. Sikaplan Disc 20 gauge, 2-3/8" round steel plate used with Sikaplan fasteners to attach membrane to the roof deck. 2. Sikaplan Fastener#15 #15 corrosion-resistant fastener used with Sarnaplates to attach Sarnatherm insulation, Sarnatherm roof boards, gypsum roof boards, or other Sika approved boards to the roof deck. 2.04 FLASHING MATERIALS A. Wall /Curb Flashing 1. Sikaplan Fastened Membrane 2. Sarnacol2175 Solvent-based, VOC compliant*, spray applied canister adhesive used to attach membrane B. Perimeter Edge Flashing A. Metal-Era One Skirted Drip Edge/ Hickman Skirted Drip Edge Fascia Two-piece assembly of galvanized steel cleat and Sarnaclad PVC coated galvanized steel with 8" (20.3 cm)wide factory applied flashing. B. Miscellaneous Flashing 1. Sarnacircles Round circle patch. 2. Sarnacorners- Inside Injection molded inside corner. 3. Sarnacorners- Outside Injection molded outside corner. 4. Sarnastack Universal Injection molded stack/pipe boot to flash pipes, vent stacks and cylindrical penetrations. 5. Sarnastack Split A, B, C Prefabricated stack/pipe boot open along one side to flash pipes, vent stacks and cylindrical penetrations when access is obstructed. 6. Sikaplan Termination Bar 3/4"wide extruded aluminum bar used to terminate Sikaplan roofing membranes at walls and edges. 2.05 WALKWAY PROTECTION A. Sikaplan Walkway-20 February 2023 4 Sika Corporation -Roofin_p Specification Sikaplan Mechanically-Attached PVC, 79 mil (2.0 mm)thick,weldable membrane with pyramidal surface embossment. Used as a protection layer from rooftop traffic. 2.06 MISCELLANEOUS ACCESSORIES A. Aluminum Tape 2" (51 mm) wide pressure-sensitive aluminum tape used as a separation layer between small areas of asphalt contamination and the membrane and as a bond-breaker under the coverstrip at Sarnaclad joints. B. Perimeter Warning Tape 2"(51 mm)wide yellow tape with a release liner used in required areas. Exceeds reflectivity 3 requirements and Federal spec. L-S-300, Class 1. C. Perimeter Warning Membrane 4" (10.2 cm)wide yellow Sarnafil G 410 Membrane used in required areas. D. SarnaRoof Membrane Cleaner 100 Used to clean roof membrane. E. Sarnacol 2175 Cleaner Used to flush and clean the Sarnacol 2175 spray hose, spray gun and spray tip. F. Sarnastop 1" wide extruded aluminum, low profile bar used with certain Sarnafasteners to secure membrane to the roof deck or to walls/curbs at terminations, penetrations and at angle changes of the substrate. 2.07 SEALANTS AND PITCH POCKET FILLERS A. Sikaflex-1 a Moisture-cured, one-component polyurethane-based, non-sag elastomeric sealant used in wall, curb and drain terminations. It is also used as a sealant at pipe penetrations and under certain metal flashings. Sikaflex-1 a can be used as a pourable sealer pocket filler. 2.08 MISCELLANEOUS FASTENERS AND ANCHORS All fasteners, anchors, nails, straps, bars, etc. shall be post-galvanized steel, aluminum or stainless steel. Mixed metal type components shall be assembled in such a manner as to avoid galvanic corrosion. Fasteners for attachment of metal to masonry shall be expansion type fasteners with stainless steel pins. PART 3 - EXECUTION 3.01 PRE-CONSTRUCTION CONFERENCE The Applicator, Owner's Representative/Designer and Manufacturer(s) shall attend a pre-construction conference. 3.02 SUBSTRATE PREPARATION A. Recover Over Existing The Owner's Representative and Applicator shall determine the condition of the existing roof deck and old roof system. Areas with deteriorated decking or wet materials are to be removed and replaced. February 2023 5 Sika Corporation -Roofin_p Specification Sikaplan Mechanically-Attached B. On smooth surfaced roofs, the surface must be clean and dry.All blisters shall be removed and sealed or cut, fastened down and sealed. 3.03 SIKAPLAN FASTENED MEMBRANE INSTALLATION The surface of the insulation, roof board, or substrate shall be inspected prior to installation of the Sikaplan roof membrane. The substrate shall be clean, dry, and free from debris and smooth with no surface roughness or contamination. Broken, delaminated,wet or damaged boards shall be removed and replaced. General Criteria 1. Sikaplan Fastened membrane shall be attached with Sikaplan Discs to withstand project specified design pressures. 2. Tack welding of Sikaplan Fastened full or half-width rolls for purposes of temporary restraint during installation is not permitted and may result in voiding of Sika Corporation warranty. 3. Sheet layout shall not buck water. 4. Hot-air weld overlaps according to Sika Corporation's recommendations. Seam test cuts shall be taken at least 3 times per day. 5. Refer to Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions A. Sikaplan Fastened System 1. Sikaplan fasteners and Sarnadiscs or Sikaplan Discs are installed along the edge of the membrane on the fastening line at a spacing determined by Sika Corporation and the Owner's Representative/Designer. 2. Fasteners shall clamp the Sikaplan Fastened membrane tightly to the substrate. 3. Adjacent rolls shall be overlapped as outlined on individual Product Data Sheets (PDS) and In-Seam Disc Placement Details/Membrane Installation section of Sika Sarnafil Roofing Applicator Handbook for specified plate and fastener combination. 3.04 HOT-AIR WELDING OF MEMBRANE OVERLAPS A. All membrane overlaps shall be hot-air welded. The membrane shall be clean and dry prior to hot-air welding. B. Field membrane overlaps for automatic machine-welding will vary in width depending on the plate and fastener combination used. A minimum of 4" (10.2 cm) wide overlap is required when hand-welding details. C. 1" (25 mm)wide cross-section samples of welded seams shall be taken at least two times a day, once in the morning and once in the afternoon. D. Refer to Welding section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.05 MEMBRANE FLASHING INSTALLATION All fleshings shall be installed concurrently with the roof membrane as the job progresses. No temporary flashings shall be allowed without the prior written approval of the Owner's Representative and Sika Corporation. Approval shall only be for specific locations on specific dates. If any water is allowed to enter under the newly completed roofing, the affected area shall be removed and replaced at the Applicator's expense. Flashing shall be adhered to compatible, dry, and smooth surfaces free of dirt, dust, and debris. Use caution to ensure adhesive fumes are not drawn into the building. A. All fleshings should extend a minimum of 8" (20.3 cm)above finished roofing level. Submit requests for exceptions in writing to the Owner's Representative and Sika Corporation Technical Department for signed approval. February 2023 6 Sika Corporation -Roofin_p Specification Sikaplan Mechanically-Attached B. No bitumen shall be in contact with the Sikaplan membrane. C. All flashing membranes shall be mechanically fastened along the counter-flashed top edge with Sarnastop or approved Sarnadisc at 6 - 12" (15.2—30.5 cm)on center. D. Flashings shall be terminated according to Sika Corporation recommended details. E. All adhered flashings that exceed 45" (1.14 m) in height shall receive additional securement, unless applying Sarnafil G 410 SA membrane to plywood, DensDeck Prime, concrete block, or concrete with a CSP of 1 —4 according to ICRI Technical Guideline No. 310.2R-2013. F. Refer to Typical Flashing Procedures section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.06 WALKWAY INSTALLATION A. Sikaplan Walkway-20 Probe all existing deck membrane seams which are to be covered by Sikaplan Walkway-20. Install walkway in straight lines by either adhering and welding or just welding to the field membrane. B. Refer to individual Product Data Sheets(PDS)and Walkway Installation section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.07 PERIMETER WARNING INSTALLATION Application areas must be cleaned to a like-new condition. For detailed installation instructions, refer to individual Product Data Sheets (PDS). A. Tape: Perimeter Warning Tape is applied with hand pressure to the top of PVC roofing membrane in the areas required. B. Membrane: Perimeter Warning Membrane is hot-air welded to the top of PVC roofing membrane in the areas required. 3.08 TEMPORARY CUT-OFF A. All fleshings shall be installed concurrently with the roof membrane in order to maintain a watertight condition as the work progresses. All temporary cut-offs shall be constructed to provide a watertight seal. The new membrane shall be carried into the temporary cut-off. Temporary cut-off shall be sealed to the deck or substrate so that water will not be allowed to travel under the new or existing roofing. When work resumes, the contaminated membrane shall be cut out. B. If inclement weather occurs while a temporary cut-off is in place, the Applicator shall provide the labor necessary to monitor the situation to maintain a watertight condition. C. If any water is allowed to enter under the newly-completed roofing, the affected area shall be removed and replaced at the Applicator's expense. D. Refer to Overnight Tie-In section of Sika Sarnafil Roofing Applicator Handbook for detailed instructions. February 2023 7 Sika Corporation -Roofin_p Specification SikaWan Mechanically-Attached 3.09 COMPLETION A. Prior to demobilization from the site, the work shall be reviewed by the Owner's Representative and the Applicator. All defects noted and non-compliances with the Specifications or the recommendations of Sika Corporation shall be itemized in a punch list. These items must be corrected immediately by the Applicator to the satisfaction of the Owner's Representative and Sika Corporation prior to demobilization. B. All Warranties referenced in this Specification shall have been submitted and have been accepted by the owner or owner's representative at time of contract award. February 2023 8 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached DISCLAIMER Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sika.com/sarnafil or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. With respect to any guide specifications prepared and provided by Sika, such guide specifications are generic and nature and are provided as a general guide for informational purposes only to architects or roof designers/specifiers. Sika guide specifications are not intended to replace sound engineering and architectural practices and should not be relied upon for that purpose. Sika assumes no liability with respect to the provision of this guide specification, the preparation of the guide specifications, the design of the roofing or waterproofing system, the preparation and approval of the details and shop drawings, or for determining their suitability for a particular project or application. The architect, consultant and/or engineer or design professional for a particular project bears the sole responsibility for the design of the roofing or waterproofing system, for the preparation of the specifications, the preparation and approval of the details and shop drawings, and for determining their suitability for a particular project or application. SIKA MAKES NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, AS TO THE CONTENTS OF THESE GUIDE SPECIFICATIONS. SIKA SHALL NOT BE RESPONSIBLE UNDER ANY LEGAL THEORY TO ANY THIRD PARTY FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING FROM THE USE OF THESE GUIDE SPECIFICATIONS. February 2023 9 SikaplanO Mechanical l CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE Z3 BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Rec-_ Sika Corporation - Roofing 'JUN 16 2023 100 Dan Road, Canton MA 02021 (800) 451-2504 usa.sika.com/sarnafil Sarnafil BUILDING TRUST Sika Corporation -Roofing Specification Sikaplan Mechanically-Attached PART 1 - GENERAL CONDITIONS 1.01 DESCRIPTION A. Scope To install a complete Sikaplan mechanically-attached system including membrane, flashings and other components. B. Related Work The work includes but is not limited to the installation of: 1. Substrate preparation 2. Roof membrane 3. Fasteners 4. Adhesive for flashings 5. Roof membrane(lashings 6. Walkways 7. Metal Flashings 8. Sealants C. Upon successful completion of work the following warranties may be obtained: 1. Sika Corporation Warranty 2. Roofing Applicator Warranty 1.02 QUALITY ASSURANCE A. This roofing system shall be applied only by a roofing applicator authorized prior to bid by Sika Corporation (Sika Corporation "Applicator'). B. A Sika Corporation Technical Service Representative will review the installed roof system wherever a System Warranty has been requested. C. All work pertaining to the installation of membrane, flashings, and accessories shall only be completed by Applicator authorized by Sika Corporation in those procedures. D. Roofing membrane manufacturer must have a demonstrated performance history of producing PVC roof membranes no less, in duration of years, than the warranty duration specified. E. Roofing membrane and membrane flashings to be manufactured by membrane supplier and not private labeled. F. Manufacturer to have a minimum ten years of experience recycling their membranes at the end of their service life back into new membrane products. Provide a minimum of five reference projects completed with new membrane produced from recycled membrane. G. Applicable code/insurance requirements shall be identified by the Owner or Owner's representative. 1.03 SUBMITTALS A. At the time of bidding, the Applicator shall submit to the Owner(or Representative)the following: A. Written approval by the insulation manufacturer(as applicable) for use of the product in the proposed system. February 2023 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached 1.04 PRODUCT DELIVERY, STORAGE,AND HANDLING A. All products delivered to the job site shall be in the original unopened containers or wrappings bearing all seals and approvals. B. Handle all materials to prevent damage. Place all materials on pallets and fully protect from moisture. C. Membrane rolls shall be stored lying down on pallets and fully protected from the weather with clean tarpaulins. Unvented tarpaulins are not accepted due to the potential accumulation of moisture beneath the tarpaulin which may affect the membrane weldability. D. As a general rule all adhesives shall be stored at temperatures between 40°F (4°C) and 80°F (27°C). Read product data sheets and instructions contained on adhesive canisters for specific storage instructions. E. All flammable materials shall be stored in a cool, dry area away from sparks and open flames. Follow precautions outlined on containers and read product Safety Data Sheets (SDS). F. Any materials which the Owner's representative or Sika Corporation determine to be damaged are to be removed from the job site and replaced at no cost to the Owner. G. Safety Data Sheets (SDS) shall be available at the job site at all times. 1.05 JOB CONDITIONS A. Only as much of the new roofing as can be made weathertight each day, including all flashing and detail work, shall be installed. All seams shall be heat welded before leaving the job site that day. B. Temporary overnight tie-ins shall be installed at the end of each day's work and shall be completely removed (including any contaminated materials) before proceeding with the next day's work. C. The Applicator shall follow all safety regulations as required by OSHA and any other applicable authority having jurisdiction. Roof and walkways may be slippery when icy, snow covered, or wet. Working on surfaces under these conditions is hazardous.Appropriate safety measures must be implemented prior to working on such surfaces. Always follow OSHA and other relevant fall protection standards when working on roofs. D. Where applicable, the Applicator shall arrange for pullout tests in accordance with the latest versions of the SPRI/ANSI Standard Field Test Procedures FX-1 and IA-1 for fasteners and adhesives, respectively, to verify condition of the deck/substrate and to confirm expected pullout values. E. The Sikaplan membrane shall not be installed under the following conditions without consulting Sika Corporation's Technical Dept. for precautionary steps: 1. The roof assembly permits interior air to pressurize the membrane underside. 2. Any exterior wall has 10% or more of the surface area comprised of opening doors or windows. 3. The wall/deck intersection permits air entry into the wall flashing area. F. Special consideration should be given to construction related moisture. Sika Corporation is not responsible for damage when exposed to construction related moisture. February 2023 2 Sika Corporation - Roofing Specification Sikaplan Mechanicallv-Attached 1.06 WARRANTIES A. Sika Corporation Warranty Upon successful completion of the work to Sika Corporation's satisfaction and receipt of final payment, the Sika Corporation Warranty shall be issued. ARE COVERED UNDER SYSTEM WARRANTY.] 1.01 System Warranty B. Contractor Warranty 1.02 WARRANTY DURATIONS A. Sika Corporation's warranty shall be in effect for a 20 year duration. PART 2 - PRODUCTS 2.01 GENERAL A. Components of the roof system shall be products of Sika Corporation as indicated on the Detail Drawings and specified in the Contract Documents. B. Components that are other than those supplied or manufactured by Sika Corporation may be submitted for review and acceptance by Sika Corporation. Sika Corporation's acceptance of any other product is only for a determination of compatibility with Sika Corporation products and not for inclusion in the Sika Corporation warranty. The specifications, installation instructions, limitations, and restrictions of the respective manufacturers must be reviewed by the Owner's Representative for acceptability for the intended use with Sika Corporation products.. 2.02 MEMBRANE A. Membrane shall conform to: 1. ASTM D-4434 (latest version), "Standard for Polyvinyl Chloride Sheet Roofing". Classification: Type III. B. Sikaplan PVC thermoplastic membrane 1. Type of Membrane a) Sikaplan Fastened 2. Membrane Thickness a) 60 mil (1.5 mm) C. Color of Membrane 1. Sikaplan Fastened a) EnergySmart White D. Typical Physical Properties 1. Refer to individual Sikaplan Fastened Product Data Sheets for physical property values. February 2023 3 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached 2.03 ATTACHMENT COMPONENTS A. Membrane Attachment Discs 1. Sikaplan Disc 20 gauge, 2-3/8" round steel plate used with Sikaplan fasteners to attach membrane to the roof deck. 2. Sikaplan Fastener#15 #15 corrosion-resistant fastener used with Sarnaplates to attach Sarnatherm insulation, Sarnatherm roof boards, gypsum roof boards, or other Sika approved boards to the roof deck. 2.04 FLASHING MATERIALS A. Wall/Curb Flashing 1. Sikaplan Fastened Membrane 2. Sarnacol2175 Solvent-based, VOC compliant*, spray applied canister adhesive used to attach membrane B. Perimeter Edge Flashing A. Metal-Era One Skirted Drip Edge/ Hickman Skirted Drip Edge Fascia Two-piece assembly of galvanized steel cleat and Sarnaclad PVC coated galvanized steel with 8"(20.3 cm)wide factory applied flashing. B. Miscellaneous Flashing 1. Sarnacircles Round circle patch. 2. Sarnacorners- Inside Injection molded inside corner. 3. Sarnacorners-Outside Injection molded outside corner. 4. Sarnastack Universal Injection molded stack/pipe boot to flash pipes, vent stacks and cylindrical penetrations. 5. Sarnastack Split A, B, C Prefabricated stack/pipe boot open along one side to flash pipes, vent stacks and cylindrical penetrations when access is obstructed. 6. Sikaplan Termination Bar 3/4"wide extruded aluminum bar used to terminate Sikaplan roofing membranes at walls and edges. 2.05 WALKWAY PROTECTION A. Sikaplan Walkway-20 February 2023 4 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached PVC, 79 mil(2.0 mm)thick,weldable membrane with pyramidal surface embossment. Used as a protection layer from rooftop traffic. 2.06 MISCELLANEOUS ACCESSORIES A. Aluminum Tape 2" (51 mm) wide pressure-sensitive aluminum tape used as a separation layer between small areas of asphalt contamination and the membrane and as a bond-breaker under the coverstrip at Sarnaclad joints. B. Perimeter Warning Tape 2" (51 mm)wide yellow tape with a release liner used in required areas. Exceeds reflectivity 3 requirements and Federal spec. L-S-300, Class 1. C. Perimeter Warning Membrane 4" (10.2 cm)wide yellow Sarnafil G 410 Membrane used in required areas. D. SarnaRoof Membrane Cleaner 100 Used to clean roof membrane. E. Sarnacol 2175 Cleaner Used to flush and clean the Sarnacol 2175 spray hose, spray gun and spray tip. F. Sarnastop 1" wide extruded aluminum, low profile bar used with certain Sarnafasteners to secure membrane to the roof deck or to walls/curbs at terminations, penetrations and at angle changes of the substrate. 2.07 SEALANTS AND PITCH POCKET FILLERS A. Sikaflex-1 a Moisture-cured, one-component polyurethane-based, non-sag elastomeric sealant used in wall, curb and drain terminations. It is also used as a sealant at pipe penetrations and under certain metal flashings. Sikaflex-1 a can be used as a pourable sealer pocket filler. 2.08 MISCELLANEOUS FASTENERS AND ANCHORS All fasteners, anchors, nails, straps, bars, etc. shall be post-galvanized steel, aluminum or stainless steel Mixed metal type components shall be assembled in such a manner as to avoid galvanic corrosion Fasteners for attachment of metal to masonry shall be expansion type fasteners with stainless steel pins. PART 3 - EXECUTION 3.01 PRE-CONSTRUCTION CONFERENCE The Applicator, Owner's Representative/Designer and Manufacturer(s) shall attend a pre-construction conference. 3.02 SUBSTRATE PREPARATION A. Recover Over Existing The Owner's Representative and Applicator shall determine the condition of the existing roof deck and old roof system. Areas with deteriorated decking or wet materials are to be removed and replaced. February 2023 5 Sika Corporation - Roofing Specification Sikaplan Mechanical)y-Attached B. On smooth surfaced roofs, the surface must be clean and dry. All blisters shall be removed and sealed or cut, fastened down and sealed. 3.03 SIKAPLAN FASTENED MEMBRANE INSTALLATION The surface of the insulation, roof board, or substrate shall be inspected prior to installation of the Sikaplan roof membrane. The substrate shall be clean, dry, and free from debris and smooth with no surface roughness or contamination. Broken, delaminated,wet or damaged boards shall be removed and replaced. General Criteria 1. Sikaplan Fastened membrane shall be attached with Sikaplan Discs to withstand project specified design pressures. 2. Tack welding of Sikaplan Fastened full or half-width rolls for purposes of temporary restraint during installation is not permitted and may result in voiding of Sika Corporation warranty. 3. Sheet layout shall not buck water. 4. Hot-air weld overlaps according to Sika Corporation's recommendations. Seam test cuts shall be taken at least 3 times per day. 5. Refer to Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions A. Sikaplan Fastened System 1. Sikaplan fasteners and Sarnadiscs or Sikaplan Discs are installed along the edge of the membrane on the fastening line at a spacing determined by Sika Corporation and the Owner's Representative/Designer. 2. Fasteners shall clamp the Sikaplan Fastened membrane tightly to the substrate. 3. Adjacent rolls shall be overlapped as outlined on individual Product Data Sheets (PDS) and In-Seam Disc Placement Details/Membrane Installation section of Sika Sarnafil Roofing Applicator Handbook for specified plate and fastener combination. 3.04 HOT-AIR WELDING OF MEMBRANE OVERLAPS A. All membrane overlaps shall be hot-air welded. The membrane shall be clean and dry prior to hot-air welding. B. Field membrane overlaps for automatic machine-welding will vary in width depending on the plate and fastener combination used. A minimum of 4" (10.2 cm) wide overlap is required when hand-welding details. C. 1" (25 mm)wide cross-section samples of welded seams shall be taken at least two times a day, once in the morning and once in the afternoon. D. Refer to Welding section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.05 MEMBRANE FLASHING INSTALLATION All flashings shall be installed concurrently with the roof membrane as the job progresses. No temporary flashings shall be allowed without the prior written approval of the Owner's Representative and Sika Corporation. Approval shall only be for specific locations on specific dates. If any water is allowed to enter under the newly completed roofing, the affected area shall be removed and replaced at the Applicator's expense. Flashing shall be adhered to compatible, dry, and smooth surfaces free of dirt, dust, and debris. Use caution to ensure adhesive fumes are not drawn into the building. A. All flashings should extend a minimum of 8" (20.3 cm) above finished roofing level. Submit requests for exceptions in writing to the Owner's Representative and Sika Corporation Technical Department for signed approval. February 2023 6 Sika Corporation- Roofina Specification Sikaplan Mechanically-Attached B. No bitumen shall be in contact with the Sikaplan membrane. C. All flashing membranes shall be mechanically fastened along the counter-flashed top edge with Sarnastop or approved Sarnadisc at 6 - 12" (15.2—30.5 cm) on center. D. Flashings shall be terminated according to Sika Corporation recommended details. E. All adhered flashings that exceed 45" (1.14 m) in height shall receive additional securement, unless applying Sarnafil G 410 SA membrane to plywood, DensDeck Prime, concrete block, or concrete with a CSP of 1 —4 according to ICRI Technical Guideline No. 310.2R-2013. F. Refer to Typical Flashing Procedures section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.06 WALKWAY INSTALLATION A. Sikaplan Walkway-20 Probe all existing deck membrane seams which are to be covered by Sikaplan Walkway-20. Install walkway in straight lines by either adhering and welding or just welding to the field membrane. B. Refer to individual Product Data Sheets(PDS)and Walkway Installation section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.07 PERIMETER WARNING INSTALLATION Application areas must be cleaned to a like-new condition. For detailed installation instructions, refer to individual Product Data Sheets (PDS). A. Tape: Perimeter Warning Tape is applied with hand pressure to the top of PVC roofing membrane in the areas required. B. Membrane: Perimeter Warning Membrane is hot-air welded to the top of PVC roofing membrane in the areas required. 3.08 TEMPORARY CUT-OFF A. All flashings shall be installed concurrently with the roof membrane in order to maintain a watertight condition as the work progresses. All temporary cut-offs shall be constructed to provide a watertight seal. The new membrane shall be carried into the temporary cut-off. Temporary cut-off shall be sealed to the deck or substrate so that water will not be allowed to travel under the new or existing roofing. When work resumes, the contaminated membrane shall be cut out. B. If inclement weather occurs while a temporary cut-off is in place, the Applicator shall provide the labor necessary to monitor the situation to maintain a watertight condition. C. If any water is allowed to enter under the newly-completed roofing, the affected area shall be removed and replaced at the Applicator's expense. D. Refer to Overnight Tie-In section of Sika Sarnafil Roofing Applicator Handbook for detailed instructions February 2023 7 Sika Corporation -Roofing Specification Sikaplan Mechanically-Attached 3.09 COMPLETION A. Prior to demobilization from the site, the work shall be reviewed by the Owner's Representative and the Applicator. All defects noted and non-compliances with the Specifications or the recommendations of Sika Corporation shall be itemized in a punch list. These items must be corrected immediately by the Applicator to the satisfaction of the Owner's Representative and Sika Corporation prior to demobilization. B. All Warranties referenced in this Specification shall have been submitted and have been accepted by the owner or owner's representative at time of contract award. February 2023 8 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached DISCLAIMER Prior to each use of any Sika product,the user must always read and follow the warnings and instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sika.com/sarnafil or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. With respect to any guide specifications prepared and provided by Sika, such guide specifications are generic and nature and are provided as a general guide for informational purposes only to architects or roof designers/specifiers. Sika guide specifications are not intended to replace sound engineering and architectural practices and should not be relied upon for that purpose. Sika assumes no liability with respect to the provision of this guide specification, the preparation of the guide specifications, the design of the roofing or waterproofing system, the preparation and approval of the details and shop drawings, or for determining their suitability for a particular project or application. The architect, consultant and/or engineer or design professional for a particular project bears the sole responsibility for the design of the roofing or waterproofing system, for the preparation of the specifications, the preparation and approval of the details and shop drawings, and for determining their suitability for a particular project or application. SIKA MAKES NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, AS TO THE CONTENTS OF THESE GUIDE SPECIFICATIONS. SIKA SHALL NOT BE RESPONSIBLE UNDER ANY LEGAL THEORY TO ANY THIRD PARTY FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING FROM THE USE OF THESE GUIDE SPECIFICATIONS. February 2023 9 ESEVALOTION IN IMES Evaluation Report ESR-1157 Reissued September 2019 This report is subject to renewal September 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE 3.2 Materials: PROTECTION 3.2.1 Sarnafil S327 Single-Ply Membrane: The Sarnafil Section:07 54 00—Thermoplastic Membrane Roofing S327 membrane is a polyester reinforced PVC membrane Section:07 5419—Polyvinyl-Chloride Roofing complying with ASTM D4434 as Type III, and available REPORT HOLDER: with or without a factory-applied felt backing. The Sarnafil S327 is manufactured in four thicknesses. See Table 4 for SIKA SARNAFIL,INC. thicknesses and weights of the membranes with and without the felt backing.The membrane is reinforced with a EVALUATION SUBJECT: polyester scrim. Sarnafil S327 is intended for installation over foam plastic insulation when attached with SARNAFIL S327, G410, G410 SAM, SIKAPLAN mechanical fasteners described in Section 3.2.9 and FASTENED AND SIKAPLAN ADHERED SINGLE-PLY Table 2. ROOFING SYSTEMS 3.2.2 Sarnafil S327 Textured Single-Ply Membrane: The Sarnafil S327 Textured membrane is a polyester 1.0 EVALUATION SCOPE reinforced PVC membrane complying with ASTM D4434 Compliance with the following codes' as Type III. The textured surface is the weather surface. The Sarnafil S327 Textured membrane is manufactured in ■ 2018, 2015, 2012, 2009 and 2006 International Building three thicknesses. See Table 4 for thicknesses and Code®(IBC) weights of the membranes. The membrane is reinforced ■ 2018, 2015, 2012, 2009 and 2006 International with a polyester scrim. Sarnafil S327 Textured membrane Residential Code®(IRC) is intended for installation over foam plastic insulation when attached with mechanical fasteners described in Properties evaluated: Section 3.2.9 and Table 2. ■ Weather resistance 3.2.3 Sarnafil G410 Single-Ply Membrane:The Sarnafil ■ Wind uplift resistance G410 membrane, typically used in adhered systems, is a glass fiber—reinforced PVC membrane complying with ■ Roof covering fire classification ASTM D4434 as Type Il, and is available with or without ■ Impact resistance factory-applied felt backing. The Sarnafil G410 is manufactured in four thicknesses. See Table 4 for 2.0 USES thicknesses and weights of the membranes with and The Sarnafil S327, G410, G410 SA, Sikaplan Fastened without the felt backing. The fiberglass reinforcement is and Sikaplan Adhered Single-Ply Roofing Systems are arranged in a woven mat. Sarnafil G410 is intended for used as classified roof covering assemblies. installation over insulation when fully adhered to the substrate using proprietary adhesives as described in 3.0 DESCRIPTION Section 3.2.10 and Table 3. 3.1 General: 3.2.4 Sarnafil G410 Textured Single-Ply Membrane: The Sarnafil Single-Ply Roofing Systems consist of single- The Sarnafil G410 Textured membrane, typically used in ply reinforced thermoplastic membranes constructed with adhered systems, is a glass fiber-reinforced PVC reinforced poly(vinyl chloride)(PVC). The systems can be membrane complying with ASTM D4434 as Type II. The installed over various types of roof decking, including textured surface is the weather surface.The Sarnafil G410 wood, steel and concrete surfaces. The systems are either Textured membrane is manufactured in three thicknesses. adhered, mechanically fastened or a combination of See Table 4 for thicknesses and weights of the mechanically fastened and adhered to resist wind uplift. membranes. The fiberglass reinforcement is arranged in a Samafil membranes are manufactured in rolls 3.25, 5, 6.5 woven mat. Sarnafil G410 Textured membrane is intended and 10 feet wide (914, 1520, 1980 and 3050 mm) with for installation over insulation when fully adhered to the lengths from 65.6 to 100 feet (20 to 30.5 m). The substrate using proprietary adhesives as described in membranes are typically manufactured with a white Section 3.2.10 and Table 3. weathering surface and a grey underside. However, 3.2.5 Sarnafil G410 SAM Single-Ply Membrane: The custom pigments are available upon request. Sarnafil G410 SAM, used in adhered systems, is a ftw£e►ved .luN 16 z0z3 ICC-ES Eval ation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed 40� vt)'< I / l as an endorsement of the subject of tie report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as if b V to anyfnnding or other matter in this report,or as to any product covered by the report. i•. , Copyright©2019[CC Evaluation Service,LLC. All rights reserved. Page 1 of 10 ESR-1157 1 Most Widely Accepted and Trusted Page 2 of 10 reinforced PVC membrane complying with ASTM D4434 insulation) to combustible or noncombustible roof decks. as Type It. The Samafil G410 SAM is manufactured in The Sikaplan Fastener #14 has a shank diameter of three thicknesses. See Table 4 for thickness and weights 0.190 inch (4.8 mm) and thread diameter of 0.245 inch of the membranes. The fiberglass reinforcement is (6.2 mm). arranged in a woven mat. The membrane has a pressure 3.2.9.4 Sarnafastener XP:The Sarnafastener XP is used sensitive adhesive backing with a release liner. Sarnafil G410 SAM is intended for installation over insulation fully with the Samadisc, described in Section 3., de r attach insulation, and with the Sarnadisc XPN, de adhered to the substrate as described in Table 3. scribed in Section 3.2.9.9, or the Sarnarail Polymer Batten, described 3.2.6 Sikaplan Fastened Single-Ply Membrane: The in Section 3.2.9.12, to attach the membrane (through the Sikaplan Fastened membrane is a polyester reinforced insulation) to combustible or noncombustible roof decks. PVC membrane complying with ASTM D4434 as Type III, The Sarnafastener XP has a shank diameter of 0.21 inch and available with or without a factory-applied felt backing. (5.3 mm)and thread diameter of 0.26 inch(6.6 mm). The Sikaplan Fastened membrane is manufactured in two 3.2.9.5 Sarnafastener MAXLoad: The Sarnafastener thicknesses. See Table 4 for thicknesses and weights of MAXLoad is used to attach the Sarnafil membrane with the the membranes with and without the felt backing. The Sarnadisc MAXLoad, described in Section 3.2.9.10, or membrane is reinforced with a polyester scrim. Sikaplan Sarnarail Polymer Batten, described in Section 3.2.9.12,to Fastened is intended for installation over foam plastic steel or combustible decks. The Sarnafastener MAXLoad insulation as indicated in Table 1 when attached with has a shank diameter of 0.26 inch (6.6 mm)and a thread mechanical fasteners described in Section 3.2.9 and Table 2. diameter of 0.33 inch(8.4 mm). 3.2.7 Sikaplan Adhered Single-Ply Membrane: The 3.2.9.6 Sarnaplate: The Sarnaplate is a 3-by-3-inch 3.2 Adhered membrane, (76 mm by 76 rnm), No. 26 gage [0.018 to 0.021 inch Sikaplantypically used in adhered (0.45 to 0.53 mm) base-metal thickness], AZ 55 systems, is a glass fiber-reinforced PVC membrane Galvalume-coated plate. complying with ASTM D4434 as Type II, and is available with or without factory-applied felt backing. The Sikaplan 3.2.9.7 Sarnadisc: The Sarnadisc is a 3-inch-diameter Adhered membranes are manufactured in two (76 mm), No. 26 gage [0.018 to 0.021 inch (0.45 to thicknesses. See Table 4 for thicknesses and weights of 0.53 mm)base-metal thickness], AZ 55 Galvalume-coated the membranes with and without the felt backing. The plate. fiberglass reinforcement is arranged in a woven mat. 3.2.9.8 Sarnadisc 23/a: Sarnadisc 23/e is 23/e-inch Sikaplan Adhered is intended for installation over (60 mm) diameter, 0.037-inch (0.94 mm) thick plate insulation that is attached to roof decks as indicated in stamped from Galvalume AZ 50 or AZ 55 steel. It has six Table 1 when fully adhered to the substrate using equally spaced "v" protrusions punched through proprietary adhesives as described in Section 3.2.10 and concentrically at 19/32-inch (15 mm) from the center of the Table 3. plate. 3.2.8 Foam Plastic Insulation: Foam plastic insulation, 3.2.9.9 Sarnadisc XPN: The Sarnadisc XPN is a V/2-by- where used,must have a flame-spread index of not greater 33/4-inch (38 by 95 mm), No. 18 gage [0.040 to 0.042 inch than 75 when tested, at the maximum thickness intended (1.00 tol.05 mm)base-metal thickness],A7_55 Galvalume- for use, in accordance with ASTM E84 or UL 723. See coated plate. Tables 1, 2 and 3 for insulations recognized for use with the respective roofing systems. 3.2.9.10 Sarnadisc MAXLoad: The Sarnadisc MAXLoad is a 3.5-inch-diameter (89 mm), No. 20 gage [0.031 to 3.2.9 Mechanical Fasteners: Substrate, fastener and 0.041 inch (0.78 to 1.02 mm)base-metal thickness],AZ 55 plate combinations must be as outlined in the Galva lume-coated plate. manufacturer's published installation instructions and Table 2 of this report. 3.2.9.11 Sarnadisc RhinoBond: Samadisc RhinoBond is a 3-inch (75 mm) diameter, 0.028-inch (0.7 mm) thick 3.2.9.1 Sarnafastener #12; The Sarnafastener #12 is metal plate coated with a polymer coating used in used with the Sarnaplate, described in Section 3.2.9.6, to conjunction with the RhinoBond induction welder to attach attach insulation boards to steel or combustible roof decks. the membrane. Sarnafastener#12 has a modified buttress thread, a shank diameter of 0.168 inch (4.3 mm) and a thread diameter of 3.2.9.12 Sarnarail Polymer Batten: The Sarnarail 0.214 inch(5.4 mm). Polymer Batten is a 1-inch-wide-by-250-foot-long-by-l/20- inch-thick(25 mm by 762 m by 1.27 mm)modified polymer 3.2.9.2 Sarnafastener #14: The Sarnafastener #14 is batten. The batten, manufactured in coils, has holes used with the Sarnaplate, described in Section 3.2.9.6, to spaced 6 inches (152 mm) on center and is used with attach insulation, and with the Sarnadisc XPN,described in either the Sarnafastener XP or the MAXLoad fasteners, Section 3.2.9.9, or the Samadisc RhinoBond, described in described in Sections 3.2.9.4 or 3.2.9.5, respectively, for Section 3.2.9.11, or the Sarnarail Polymer Batten, securing the roof membrane. described in Section 3.2.9.12 to attach the membrane (through the insulation) to combustible or noncombustible 3.2.10 Adhesives: roof decks. The Sarnafastener#14 has a shank diameter 3.2.10.1 Sarnacol 2170: Sarnacol 2170 is a solvent-based of 0.190 inch (4.8 mm) and thread diameter of 0.245 inch adhesive for bonding Sarnafil membranes to foam plastic (6.2 mm). substrates or Georgia-Pacific LLC DensDeck Roofboard 3.2.9.3 Sikaplan Fastener #14: The Sikaplan Fastener with application rates as specified in Table 3. Samacol #14 is used with the Sarnaplate, described in Section 2170 is supplied in 5-gallon (18.9 L) steel containers. The 3.2.9.6, to attach insulation, and with the Samadisc 23/8, shelf life is one year when the adhesive is stored in the described in Section 3.2.9.8, Sarnadisc XPN, described in original unopened container at temperatures between 40"F Section 3.2.9.9, Samadisc RhinoBond, described in and 80"F(4.4"C and 26.7"C). Section 3.2.9.11, or Sarnarail Polymer Batten, described 3.2.10.2 Sarnacol 2170 VC: Sarnacol 2170 VC is a in Section 3.2.9.12, to attach the membrane (through the solvent-based adhesive used for bonding Samafil ESR-1157 I Most Widely Accepted and Trusted Page 3 of 10 membranes to foam plastic substrates or Georgia-Pacific systems. The systems must be installed at the maximum LLC DensDeck® Roof Board with application rates as slope specified in Table 1. specified in Table 3. Samocol 2170 VC is supplied in 4.3 Wind Resistance: 5-gallon (18.9 L)steel containers.The shelf life is one year when the adhesive is stored in the original unopened See Tables 2 and 3 for a full description of components, container at temperatures between 40°F and 80'F (4.4°C fastener spacing, adhesive application and allowable and 26.7°C). design wind uplift pressures for each of the evaluated 3.2.10.3 Sarnacol 2121: Sarnacol 2121 is a water-based systems. adhesive for bonding Sarnafil membranes to foam plastic 4.3.1 Metal Edge Securement Systems: Metal edge substrates or Georgia-Pacific LLC DensDeck® Roof Board securement systems must be listed in accordance with the with application rates as specified in Table 3. Samacol 2011 edition of ANSI/SPRI/FM 4435 ES-1, and designed 2121 is supplied in 5-gallon (18.9 L) steel containers. The and installed for wind loads in accordance with 2018 and shelf life is one year when the adhesive is stored in the 2015 IBC Section 1504.5 and 2018 and 2015 IBC Chapter original unopened container at temperatures between 40°F 16 [2003 edition of ANSI/SPRI/FM 4435 ES-1, and and 80°F(4.4°C and 26.7°C). designed and installed for wind loads in accordance with 3.2.10.4 Samacol AD Feltback Membrane Adhesive: 2012, 2009 and 2006 IBC Section 1504.5 and 2012, 2009 and 2006 IBC Chapter 16]. Sarnacol AD Adhesive is a two-part liquid applied non- asphaltic urethane adhesive that transforms into a low rise 4.4 Flashing: foam during the curing process.The adhesive is packaged Flashing must be provided as required by IBC Section in 0.16-gallon (600 mL) cartridges, four to a box or 1503.2.1 or IRC Section R903.2.1, as applicable. Where 10-gallon (37.8 L)box sets consisting of two parts: (Part 1 flashing is of metal, the metal must be corrosion-resistant - 5-gallon (18.9 L) and Part 2 - 5-gallon (18.9 L)). The with a thickness of not less than No. 26 gage[base-metal shelf life is 18 months when the adhesive is stored in the thickness of 0.019 inch(0.5 mm)]. original unopened container at temperatures between 45°F and 95°F(7°C and 35°C). 4.5 Reroofing: 3.2.10.5 Sarnacol OM Feltback Membrane Adhesive: The existing deck must be inspected to verify that the Sarnacol OM Adhesive is a two-part low rise polyurethane structure to be reroofed is structurally sound and adequate adhesive that is applied in one step, dispensed at a 1:1 to support and secure the roofing membrane. Prior to ratio. The adhesive is packaged in 0.16-gallon (600 mL) installation of new roof coverings, inspection by, and cartridges, four to a box or 10-gallon (37.8 L) box sets written approval from, the code official having jurisdiction consisting of two parts: (Part 1 -5-gallon(18.9 L)and Part are required in accordance with 2018 and 2015 IBC 2-5-gallon (18.9 L)).The shelf life is 18 months when the Section 1511 [2012, 2009 and 2006 IBC Section 1510]. adhesive is stored in the original unopened container at The roof covering systems described in this report, temperatures between 55°F and 857 (12.8°C and installed over an existing roof covering system, must be 29.5°C). shown to satisfy classification requirements by testing of the composite system in accordance with ASTM E108 or 3.2.11 Barrier Board: Barrier board, where used, must be UL 790. As an alternative, Class A, B or C roof covering a minimum of 1/4-inch (6.4 mm) DensDeck® Roof Board systems are permitted to be installed over existing manufactured by Georgia-Pacific LLC classified roof covering systems under the following 3.3 Impact Resistance: conditions without additional roof classification tests, provided the resulting classification is the lower of the The Sarnafil S327 and G410 Single-Ply Roofing Systems classification for the new and existing roofing: described in this report comply with the requirements for impact resistance in accordance with Section 4.6 of • New uninsulated systems installed only over existing FM 4470. uninsulated assemblies. 4.0 INSTALLATION • New insulated systems installed only over existing uninsulated system 4.1 General: 5.O CONDITIONS OF USE Installation of the Sarnafil S327, G410, G410 SAM, Sikaplan Fastened and Sikaplan Adhered Single-Ply The Sarnafil S327, G410, G410 SAM, Sikaplan Fastened Roofing Systems must comply with the applicable code, and Sikaplan Adhered Single-Ply Roofing Systems this report and the manufacturer's published installation described in this report comply with, or are suitable instructions. The manufacturer's published installation alternatives to what is specified in, the codes indicated in instructions must be available at the jobsite at all times Section 1.0 of this report, subject to the following during installation. The substrate must be smooth, dry, conditions: clean and free of sharp projections, loose fasteners, 5.1 Installation must comply with this report, the protrusions, depressions or contaminants that might manufacturer's published instructions and the interfere with the adhesion or attachment of the applicable code. If there is a conflict between the membrane.Any surface defects must be corrected prior to manufacturer's published installation instructions and the membrane installation.All materials must be protected this report,this report governs. against contact with incompatible materials. The roof 5.2 The Sarnafil S327, G410, G410 SAM, Sikaplan systems must not be installed on roofs having slopes less Fastened and Sikaplan Adhered Single-Ply Roofing than /4:12(2 percent slope)or more than that specified for Systems must be installed by a Sarnafil, Inc., trained the particular assembly as listed in Table 1 for the and approved contractor. Evidence of this approval corresponding assembly and roof classification. must be made available to the code official upon 4.2 Roof Covering Classification: request. See Table 1 for a full description of components and the 5.3 Design wind uplift pressures on any roof area, roof covering classification for each of the evaluated including edge and comer zones, must not exceed BUILDING TRUST PRODUCT DATA SHEET SikaplanO Fastened-60 EnergySmart 60 mil thick PVC thermoplastic membrane PRODUCT DESCRIPTION CHARACTERISTICS/ADVANTAGES Sikaplan®Fastened-60 EnergySmart Roof Membrane is a PVC thermoplastic membrane produced with a polyester scrim reinforcement. � Zer������ USES Roof Mechanically attached using various attachment • Highly reflective components over approved substrates.It may also be • Excellent tear strength resistance used in adhered applications to approved substrates. • Factory applied lacquer coating to reduce dirt pick up • Hot-air welded seams for long-term performance AREAS OF APPLICATION APPROVALS/STANDARDS • In-seam disc systems • In-seam batten,double-weld systems FM Global] • RhinoBond®systems Underwriters Laboratories • Adhered systems • Underwriters Laboratories of Canada • New construction and reroofing ICC Code Compliance—ESR 1157 • Miami-Dade County • Florida Building Code • California Title 24 • LEED/Green Globes ]Mechanically attached only. Product Data Sheet vV �tjtA Sikaplan•Fastened-60 EnergySmart e September 2022,Version 07 01 020905011050153002 JUN y �p 2023 1/4 PRODUCT INFORMATION Chemical Base Thermoplastic PVC membrane containing ultraviolet light stabilizers,flame retardant and polyester scrim reinforcement with a unique lacquer coating on the top surface. Recycled Content 9%Pre-consumer, 1%Post-consumer Reinforcing Material Polyester Packaging 60 mil(1.5 mm)Membrane 10 ft x 100 ft(3 m x 30 m)roll,343 Ibs(156 kg)per roll, 8 rolls per pallet 5 ft x 100 ft(1.5 m x 30 m)roll,172 Ibs(78 kg)per roll, 12 rolls per pallet Shelf Life N/A Storage Conditions Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins.Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability. Appearance/Color • Top:White,Reflective Gray,and Tan • Bottom:Gray Overall Thickness 60 mil(1.5 mm),nominal (ASTM D-751) 45 mil (ASTM Type III D-4434 Spec.Requirement) Thickness Above Scrim 24 mil (ASTM D-7635) 16 mil (ASTM Type III D-4434 Spec.Requirement) TECHNICAL INFORMATION Resistance to Static Puncture Pass (ASTM D-5602) 33 Ibf(15 kg) (ASTM Type III D-4434 Spec.Requirement) Resistance to Dynamic Puncture Pass (ASTM D-5635) 14.7 ft-Ibf(20 J) (ASTM Type III D-4434 Spec.Requirement) Tensile Strength 303 Ibf(1348 N) (ASTM D-751) 200 Ibf(890 N) (ASTM Type III D-4434 Spec.Requirement) Elongation at Break 20&20%MD&CMD1 (ASTM D-751) 15&15%MD&CMD1 (ASTM Type III D-4434 Spec.Requirement) 1 MD=Machine Direction,CMD=Cross Machine Direction. Tear Strength 45 Ibf(200 N) (ASTM D-751) 45 Ibf(200 N) (ASTM Type III D-4434 Spec.Requirement) Seam Strength Pass (ASTM D-751) 75%of original2 (ASTM Type III D-4434 Spec.Requirement) 2 Failure occurs through membrane rupture not seam failure. Linear Dimensional Change 0.24% (ASTM D-1204) 0.5% (ASTM Type III D-4434 Spec.Requirement) Product Data Sheet Sikaplan°Fastened-60 Energy5mart September 2022,Version 07 01 020905011050153002 BUILDING TRUST 2/4 Solar Reflectance EnergySmart Colors Initial Solar 3-Year Solar Reflectance' _ Reflectance' EnergySmart 0.85 0.75 White _ EnergySmart 0.73 0.66 Reflective Gray EnergySmart 0.72 0.65 Tan 'Solar Reflectance testing according to ASTM C-1549. Solar Reflectance Index EnergySmart Colors Initial Solar 3-Year Solar Reflectance Index' Reflectance Index' EnergySmart 107 93 White EnergySmart 90 80 Reflective Gray EnergySmart 88 78 Tan 1 Solar Reflectance Index calculated according to ASTM E-1980. Thermal Emittance EnergySmart Colors Initial Thermal 3-Year Thermal Emittancel Emittance' EnergySmart 0.89 0.90 White EnergySmart 0.89 0.88 Reflective Gray EnergySmart 0.89 0.88 Tan 1 Thermal Emittance testing according to ASTM C-1371,Slide Method. Low Temperature Bend Pass (ASTM D-2136) Pass-40oF(-40oC) (ASTM Type III D-4434 Spec.Requirement) Weight Change after Immersion in Water 2.5% (ASTM D-570) +3 0% (ASTM Type III D-4434 Spec.Requirement) UV Exposure 10,000 hours (ASTM G-154) 5,000 hours (ASTM Type III D-4434 Spec.Requirement) Cracking None (7x magnification) Discoloration Negligible (by observation) Crazing None (7x magnification) Retention of Properties after Heat Ageing Tensile Strength,%of original: Pass (ASTM D-3045) Elongation,%of original:Pass (ASTM D-751) Tensile Strength,%of original:90 (ASTM Type III D-4434 Spec.Requirement) Elongation,%of original:90 BASIS OF PRODUCT DATA AVAILABILITY/WARRANTY Results may differ based upon statistical variations AVAILABILITY depending upon mixing methods and equipment, temperature,application methods,test methods,actual From Sika Corporation—Roofing Authorized Applicators site conditions and curing conditions. for use within Sarnafil or Sikaplan systems. Product Data Sheet Sikaplan'Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 BUILDING TRUST A& 3/4 LEGAL DISCLAIMER WARRANTY •KEEP CONTAINER TIGHTLY CLOSED •KEEP OUT OF REACH OF CHILDREN Upon successful completion of the installed roof by the .NOT FOR INTERNAL CONSUMPTION Sika Authorized Applicator in compliance with Sika •FOR INDUSTRIAL USE ONLY requirements,Sika Corporation will provide a warranty .FOR PROFESSIONAL USE ONLY to the Building Owner via the Sika Authorized Applicator. ENVIRONMENTAL HEALTH AND SAFETY Prior to each use of any product of Sika Corporation,its subsidiaries or affiliates("SIKA"),the user must always read and follow the warnings and instructions on the For further information and advice regarding product's most current product label,Product Data transportation,handling,storage and disposal of Sheet and Safety Data Sheet which are available at chemical products,user should refer to the actual Safety usa.sika.com or by calling SIKA's Technical Service Data Sheets containing physical,environmental, Department at 1-800-933-7452.Nothing contained in toxicological and other safety related data. User must any SIKA literature or materials relieves the user of the read the current actual Safety Data Sheets before using obligation to read and follow the warnings and any products.In case of an emergency,call CHEMTREC instructions for each SIKA product as set forth in the at 1-800-424-9300,International 703-527-3887. current product label, Product Data Sheet and Safety APPLICATION INSTRUCTIONS Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of APPLICATION installation to be free from manufacturing defects and Sikaplan Fastened is installed on acceptable substrates to meet the technical properties on the current Product and fastened to the roof deck usingthe a Data Sheet if used as directed within the product's shelf ons,the life. User determines suitability of product for intended attachment method. In adhered applications,the use and assumes all risks.User's and/or buyer's sole membrane is unrolled into approved Sikaplan or Sarnacol adhesive in accordance with Sika's technical remedy shall be limited to the purchase price orreplacement of this product exclusive of any labor costs. requirements and then pressed into place with a NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL minimum 75 lb(34 kg)steel roller.The membrane is APPLY INCLUDING ANY WARRANTY OF heat-welded together by trained mechanics using hot-air MERCHANTABILITY OR FITNESS FOR A PARTICULAR welding equipment.Sikaplan Fastened can be used for PURPOSE.SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL fleshings on Sikaplan Fastened and Sikaplan Adhered THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. roof projects. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS MAINTENANCE PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD Standard maintenance of Sikaplan systems should BY OTHERS. include regular inspections of flashings,drains and Sale of SIKA products are subject to the Terms and terminations sealants at least twice a year and after Conditions of Sale which are available at each storm. https://usa.sika.com/en/group/SikaCorp/termsandconditions.htmi OTHER RESTRICTIONS or by calling 1-800-933-7452. See Legal Disclaimer. Slka Corporation 201 Polito Avenue Lyndhurst,NJ 07071 Phone:+1-800-933-7452 Fax:+1-201-933-6225 usa sika.mm SikaplanFastened-60Energy5mart-en-US-(09-2022)-7-1 pdf Product Data Sheet Sikaplan*Fastened-60 EnergySmart September 2022,Version 07 01 020905011050153002 4/4 BUILDING TRUST v Q a c c Q uj GJ w w 3 c o o m o cwe o io is cc 5 Y n c0 C.) U U V U E U O. U _ J J L$ Q J Q m > > o m 3 z - N W — - w J J W_c-c E > > c O c N _m T Eo Eo y c c °� Eo �1 L GD f- V Y S. :L••,d y •y M U •.L.. C V \ 1�I W N 3: 3 � m x x O R u ¢ o Q p m m o. Q L o: c c ¢ o ¢ w dy O c Q v c' ca v rn z L'v z vcr cc = CA J J J J-� w w c O y O �� ca cc c cv ,+ c� Q m E o E o = l ) G1 L L d w co c0 C cd VV rn E � t CD to 3 Y 3 > U O O Q a 0 ¢ O •Q d G w w G w 0 U U G J J co a T w m w n ¢ ¢ Q o- ¢ o T E o wrn 5Im o o o o voi w j U_ U_ Z Z Z U Z C O w LL j� _� J �\ cp C 7 m w c0 U ` rVl o f o` cu Q Q o o Q w m w U O av+ o twn id id w o o U w (d O� 3 C.) U U L 1 Z n76 J CLA p U U _. O O J J o m m E > O .6cc -0 -3 `o� •3 o a y c c ¢ Q ¢ m a W u_ O1 ¢m ca ¢m o U y w h �' ca w `° c� c w m a v, m x x c" cc m 5 n E aoi o W s Y _cc co w= a5 � ai y V U ¢ U v'y oo Um Q A ca O O o O c c L o O Q x x 3 V w — `L vi o w fO = wcc m wm U o �+w a L) E w O.= E d in =� O w U w Q U O U O d G OJ L U'[/) -a m m U d U T J U J U Q Q C N E;)t d y c0 Q LL 3 z z in Ew m a E E z CD` O Q Q Q Q Q Q �pFD w co co Vf o 0 0 co o 0 c ? c0 C.> V C O U U U U _ O O J_ J J Z 1 w w (n m Em OJ o o N o y ^ c t a� a� w U U I a o v, o. U w d J J co C S C (A C Q` c0 w cd �• C C wcl w w O co y ,_ O O w VJ of w w L w _T L L L L U x X O 3 ca•� a 3 Cn m o W V Qo ¢ o t c c Q w m Cl V L t eo _ c E 'o N cc V U U Q a[ 2 --I o 0 E cc C� J J w Z U U w U L c6 O. • • w0 O L_ -- J awo n o ccu _ Jca oQ � Q � o 3+ o d d w� wa fw.) o TN co cY_a N E h y wn coi ca y -a o � o � •n n ncc`dcw ym� m m � m G O O E T J U J U Q ¢ 5 E y d 'a E X J J L J W I— E E a ca LL 3 3 z z inw caa E � (j} _ • o E w L a - - 3 c d o z cD E — 0 3 0 0 3 �_ E w c� a U O '~ L fA T C L � O_ C d cu CD C QJ C a1 w W N O.Q w ++ O y+ m c ccv o 0 0-in l E L co 0\ '�. y cn+ /�3 3 o p- ea �°-'�' co w ca a� " E w C. n J " w a I Yl w L ® O p w w m T LL. '� N 3 V y d E LL E a' > >' N w c C E LL c E O U. c m c s w w p c y a rn a Y ` cam y .o '.°- mcc'o LSE ' C� E, c°.� I + Coc � cwci '�o a W y +L.-• W tL c C o c 1L m N o H •` LL w co.+ _ a LL w o o a cEp .J 3 d y 0 d a 7 `p L ~ N E p m , W 0 ~E O Y C p w w N O L Q C .^i w O c0 U L C E Q] a w C O E T CL L C � w O � - t U N O LL cocL a O O �- c) w cis F- a co O a`� E E w y d w u 1 ~ w o w o CL w c° T - N - O_ L cL SikaplanO Mechanical l CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE Z3 BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Rec-_ Sika Corporation - Roofing 'JUN 16 2023 100 Dan Road, Canton MA 02021 (800) 451-2504 usa.sika.com/sarnafil Sarnafil BUILDING TRUST Sika Corporation -Roofing Specification Sikaplan Mechanically-Attached PART 1 - GENERAL CONDITIONS 1.01 DESCRIPTION A. Scope To install a complete Sikaplan mechanically-attached system including membrane, flashings and other components. B. Related Work The work includes but is not limited to the installation of: 1. Substrate preparation 2. Roof membrane 3. Fasteners 4. Adhesive for flashings 5. Roof membrane(lashings 6. Walkways 7. Metal Flashings 8. Sealants C. Upon successful completion of work the following warranties may be obtained: 1. Sika Corporation Warranty 2. Roofing Applicator Warranty 1.02 QUALITY ASSURANCE A. This roofing system shall be applied only by a roofing applicator authorized prior to bid by Sika Corporation (Sika Corporation "Applicator'). B. A Sika Corporation Technical Service Representative will review the installed roof system wherever a System Warranty has been requested. C. All work pertaining to the installation of membrane, flashings, and accessories shall only be completed by Applicator authorized by Sika Corporation in those procedures. D. Roofing membrane manufacturer must have a demonstrated performance history of producing PVC roof membranes no less, in duration of years, than the warranty duration specified. E. Roofing membrane and membrane flashings to be manufactured by membrane supplier and not private labeled. F. Manufacturer to have a minimum ten years of experience recycling their membranes at the end of their service life back into new membrane products. Provide a minimum of five reference projects completed with new membrane produced from recycled membrane. G. Applicable code/insurance requirements shall be identified by the Owner or Owner's representative. 1.03 SUBMITTALS A. At the time of bidding, the Applicator shall submit to the Owner(or Representative)the following: A. Written approval by the insulation manufacturer(as applicable) for use of the product in the proposed system. February 2023 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached 1.04 PRODUCT DELIVERY, STORAGE,AND HANDLING A. All products delivered to the job site shall be in the original unopened containers or wrappings bearing all seals and approvals. B. Handle all materials to prevent damage. Place all materials on pallets and fully protect from moisture. C. Membrane rolls shall be stored lying down on pallets and fully protected from the weather with clean tarpaulins. Unvented tarpaulins are not accepted due to the potential accumulation of moisture beneath the tarpaulin which may affect the membrane weldability. D. As a general rule all adhesives shall be stored at temperatures between 40°F (4°C) and 80°F (27°C). Read product data sheets and instructions contained on adhesive canisters for specific storage instructions. E. All flammable materials shall be stored in a cool, dry area away from sparks and open flames. Follow precautions outlined on containers and read product Safety Data Sheets (SDS). F. Any materials which the Owner's representative or Sika Corporation determine to be damaged are to be removed from the job site and replaced at no cost to the Owner. G. Safety Data Sheets (SDS) shall be available at the job site at all times. 1.05 JOB CONDITIONS A. Only as much of the new roofing as can be made weathertight each day, including all flashing and detail work, shall be installed. All seams shall be heat welded before leaving the job site that day. B. Temporary overnight tie-ins shall be installed at the end of each day's work and shall be completely removed (including any contaminated materials) before proceeding with the next day's work. C. The Applicator shall follow all safety regulations as required by OSHA and any other applicable authority having jurisdiction. Roof and walkways may be slippery when icy, snow covered, or wet. Working on surfaces under these conditions is hazardous.Appropriate safety measures must be implemented prior to working on such surfaces. Always follow OSHA and other relevant fall protection standards when working on roofs. D. Where applicable, the Applicator shall arrange for pullout tests in accordance with the latest versions of the SPRI/ANSI Standard Field Test Procedures FX-1 and IA-1 for fasteners and adhesives, respectively, to verify condition of the deck/substrate and to confirm expected pullout values. E. The Sikaplan membrane shall not be installed under the following conditions without consulting Sika Corporation's Technical Dept. for precautionary steps: 1. The roof assembly permits interior air to pressurize the membrane underside. 2. Any exterior wall has 10% or more of the surface area comprised of opening doors or windows. 3. The wall/deck intersection permits air entry into the wall flashing area. F. Special consideration should be given to construction related moisture. Sika Corporation is not responsible for damage when exposed to construction related moisture. February 2023 2 Sika Corporation - Roofing Specification Sikaplan Mechanicallv-Attached 1.06 WARRANTIES A. Sika Corporation Warranty Upon successful completion of the work to Sika Corporation's satisfaction and receipt of final payment, the Sika Corporation Warranty shall be issued. ARE COVERED UNDER SYSTEM WARRANTY.] 1.01 System Warranty B. Contractor Warranty 1.02 WARRANTY DURATIONS A. Sika Corporation's warranty shall be in effect for a 20 year duration. PART 2 - PRODUCTS 2.01 GENERAL A. Components of the roof system shall be products of Sika Corporation as indicated on the Detail Drawings and specified in the Contract Documents. B. Components that are other than those supplied or manufactured by Sika Corporation may be submitted for review and acceptance by Sika Corporation. Sika Corporation's acceptance of any other product is only for a determination of compatibility with Sika Corporation products and not for inclusion in the Sika Corporation warranty. The specifications, installation instructions, limitations, and restrictions of the respective manufacturers must be reviewed by the Owner's Representative for acceptability for the intended use with Sika Corporation products.. 2.02 MEMBRANE A. Membrane shall conform to: 1. ASTM D-4434 (latest version), "Standard for Polyvinyl Chloride Sheet Roofing". Classification: Type III. B. Sikaplan PVC thermoplastic membrane 1. Type of Membrane a) Sikaplan Fastened 2. Membrane Thickness a) 60 mil (1.5 mm) C. Color of Membrane 1. Sikaplan Fastened a) EnergySmart White D. Typical Physical Properties 1. Refer to individual Sikaplan Fastened Product Data Sheets for physical property values. February 2023 3 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached 2.03 ATTACHMENT COMPONENTS A. Membrane Attachment Discs 1. Sikaplan Disc 20 gauge, 2-3/8" round steel plate used with Sikaplan fasteners to attach membrane to the roof deck. 2. Sikaplan Fastener#15 #15 corrosion-resistant fastener used with Sarnaplates to attach Sarnatherm insulation, Sarnatherm roof boards, gypsum roof boards, or other Sika approved boards to the roof deck. 2.04 FLASHING MATERIALS A. Wall/Curb Flashing 1. Sikaplan Fastened Membrane 2. Sarnacol2175 Solvent-based, VOC compliant*, spray applied canister adhesive used to attach membrane B. Perimeter Edge Flashing A. Metal-Era One Skirted Drip Edge/ Hickman Skirted Drip Edge Fascia Two-piece assembly of galvanized steel cleat and Sarnaclad PVC coated galvanized steel with 8"(20.3 cm)wide factory applied flashing. B. Miscellaneous Flashing 1. Sarnacircles Round circle patch. 2. Sarnacorners- Inside Injection molded inside corner. 3. Sarnacorners-Outside Injection molded outside corner. 4. Sarnastack Universal Injection molded stack/pipe boot to flash pipes, vent stacks and cylindrical penetrations. 5. Sarnastack Split A, B, C Prefabricated stack/pipe boot open along one side to flash pipes, vent stacks and cylindrical penetrations when access is obstructed. 6. Sikaplan Termination Bar 3/4"wide extruded aluminum bar used to terminate Sikaplan roofing membranes at walls and edges. 2.05 WALKWAY PROTECTION A. Sikaplan Walkway-20 February 2023 4 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached PVC, 79 mil(2.0 mm)thick,weldable membrane with pyramidal surface embossment. Used as a protection layer from rooftop traffic. 2.06 MISCELLANEOUS ACCESSORIES A. Aluminum Tape 2" (51 mm) wide pressure-sensitive aluminum tape used as a separation layer between small areas of asphalt contamination and the membrane and as a bond-breaker under the coverstrip at Sarnaclad joints. B. Perimeter Warning Tape 2" (51 mm)wide yellow tape with a release liner used in required areas. Exceeds reflectivity 3 requirements and Federal spec. L-S-300, Class 1. C. Perimeter Warning Membrane 4" (10.2 cm)wide yellow Sarnafil G 410 Membrane used in required areas. D. SarnaRoof Membrane Cleaner 100 Used to clean roof membrane. E. Sarnacol 2175 Cleaner Used to flush and clean the Sarnacol 2175 spray hose, spray gun and spray tip. F. Sarnastop 1" wide extruded aluminum, low profile bar used with certain Sarnafasteners to secure membrane to the roof deck or to walls/curbs at terminations, penetrations and at angle changes of the substrate. 2.07 SEALANTS AND PITCH POCKET FILLERS A. Sikaflex-1 a Moisture-cured, one-component polyurethane-based, non-sag elastomeric sealant used in wall, curb and drain terminations. It is also used as a sealant at pipe penetrations and under certain metal flashings. Sikaflex-1 a can be used as a pourable sealer pocket filler. 2.08 MISCELLANEOUS FASTENERS AND ANCHORS All fasteners, anchors, nails, straps, bars, etc. shall be post-galvanized steel, aluminum or stainless steel Mixed metal type components shall be assembled in such a manner as to avoid galvanic corrosion Fasteners for attachment of metal to masonry shall be expansion type fasteners with stainless steel pins. PART 3 - EXECUTION 3.01 PRE-CONSTRUCTION CONFERENCE The Applicator, Owner's Representative/Designer and Manufacturer(s) shall attend a pre-construction conference. 3.02 SUBSTRATE PREPARATION A. Recover Over Existing The Owner's Representative and Applicator shall determine the condition of the existing roof deck and old roof system. Areas with deteriorated decking or wet materials are to be removed and replaced. February 2023 5 Sika Corporation - Roofing Specification Sikaplan Mechanical)y-Attached B. On smooth surfaced roofs, the surface must be clean and dry. All blisters shall be removed and sealed or cut, fastened down and sealed. 3.03 SIKAPLAN FASTENED MEMBRANE INSTALLATION The surface of the insulation, roof board, or substrate shall be inspected prior to installation of the Sikaplan roof membrane. The substrate shall be clean, dry, and free from debris and smooth with no surface roughness or contamination. Broken, delaminated,wet or damaged boards shall be removed and replaced. General Criteria 1. Sikaplan Fastened membrane shall be attached with Sikaplan Discs to withstand project specified design pressures. 2. Tack welding of Sikaplan Fastened full or half-width rolls for purposes of temporary restraint during installation is not permitted and may result in voiding of Sika Corporation warranty. 3. Sheet layout shall not buck water. 4. Hot-air weld overlaps according to Sika Corporation's recommendations. Seam test cuts shall be taken at least 3 times per day. 5. Refer to Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions A. Sikaplan Fastened System 1. Sikaplan fasteners and Sarnadiscs or Sikaplan Discs are installed along the edge of the membrane on the fastening line at a spacing determined by Sika Corporation and the Owner's Representative/Designer. 2. Fasteners shall clamp the Sikaplan Fastened membrane tightly to the substrate. 3. Adjacent rolls shall be overlapped as outlined on individual Product Data Sheets (PDS) and In-Seam Disc Placement Details/Membrane Installation section of Sika Sarnafil Roofing Applicator Handbook for specified plate and fastener combination. 3.04 HOT-AIR WELDING OF MEMBRANE OVERLAPS A. All membrane overlaps shall be hot-air welded. The membrane shall be clean and dry prior to hot-air welding. B. Field membrane overlaps for automatic machine-welding will vary in width depending on the plate and fastener combination used. A minimum of 4" (10.2 cm) wide overlap is required when hand-welding details. C. 1" (25 mm)wide cross-section samples of welded seams shall be taken at least two times a day, once in the morning and once in the afternoon. D. Refer to Welding section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.05 MEMBRANE FLASHING INSTALLATION All flashings shall be installed concurrently with the roof membrane as the job progresses. No temporary flashings shall be allowed without the prior written approval of the Owner's Representative and Sika Corporation. Approval shall only be for specific locations on specific dates. If any water is allowed to enter under the newly completed roofing, the affected area shall be removed and replaced at the Applicator's expense. Flashing shall be adhered to compatible, dry, and smooth surfaces free of dirt, dust, and debris. Use caution to ensure adhesive fumes are not drawn into the building. A. All flashings should extend a minimum of 8" (20.3 cm) above finished roofing level. Submit requests for exceptions in writing to the Owner's Representative and Sika Corporation Technical Department for signed approval. February 2023 6 Sika Corporation- Roofina Specification Sikaplan Mechanically-Attached B. No bitumen shall be in contact with the Sikaplan membrane. C. All flashing membranes shall be mechanically fastened along the counter-flashed top edge with Sarnastop or approved Sarnadisc at 6 - 12" (15.2—30.5 cm) on center. D. Flashings shall be terminated according to Sika Corporation recommended details. E. All adhered flashings that exceed 45" (1.14 m) in height shall receive additional securement, unless applying Sarnafil G 410 SA membrane to plywood, DensDeck Prime, concrete block, or concrete with a CSP of 1 —4 according to ICRI Technical Guideline No. 310.2R-2013. F. Refer to Typical Flashing Procedures section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.06 WALKWAY INSTALLATION A. Sikaplan Walkway-20 Probe all existing deck membrane seams which are to be covered by Sikaplan Walkway-20. Install walkway in straight lines by either adhering and welding or just welding to the field membrane. B. Refer to individual Product Data Sheets(PDS)and Walkway Installation section of Sika Sarnafil Roofing Applicator Handbook for detailed installation instructions. 3.07 PERIMETER WARNING INSTALLATION Application areas must be cleaned to a like-new condition. For detailed installation instructions, refer to individual Product Data Sheets (PDS). A. Tape: Perimeter Warning Tape is applied with hand pressure to the top of PVC roofing membrane in the areas required. B. Membrane: Perimeter Warning Membrane is hot-air welded to the top of PVC roofing membrane in the areas required. 3.08 TEMPORARY CUT-OFF A. All flashings shall be installed concurrently with the roof membrane in order to maintain a watertight condition as the work progresses. All temporary cut-offs shall be constructed to provide a watertight seal. The new membrane shall be carried into the temporary cut-off. Temporary cut-off shall be sealed to the deck or substrate so that water will not be allowed to travel under the new or existing roofing. When work resumes, the contaminated membrane shall be cut out. B. If inclement weather occurs while a temporary cut-off is in place, the Applicator shall provide the labor necessary to monitor the situation to maintain a watertight condition. C. If any water is allowed to enter under the newly-completed roofing, the affected area shall be removed and replaced at the Applicator's expense. D. Refer to Overnight Tie-In section of Sika Sarnafil Roofing Applicator Handbook for detailed instructions February 2023 7 Sika Corporation -Roofing Specification Sikaplan Mechanically-Attached 3.09 COMPLETION A. Prior to demobilization from the site, the work shall be reviewed by the Owner's Representative and the Applicator. All defects noted and non-compliances with the Specifications or the recommendations of Sika Corporation shall be itemized in a punch list. These items must be corrected immediately by the Applicator to the satisfaction of the Owner's Representative and Sika Corporation prior to demobilization. B. All Warranties referenced in this Specification shall have been submitted and have been accepted by the owner or owner's representative at time of contract award. February 2023 8 Sika Corporation - Roofing Specification Sikaplan Mechanically-Attached DISCLAIMER Prior to each use of any Sika product,the user must always read and follow the warnings and instructions on the product's most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sika.com/sarnafil or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. With respect to any guide specifications prepared and provided by Sika, such guide specifications are generic and nature and are provided as a general guide for informational purposes only to architects or roof designers/specifiers. Sika guide specifications are not intended to replace sound engineering and architectural practices and should not be relied upon for that purpose. Sika assumes no liability with respect to the provision of this guide specification, the preparation of the guide specifications, the design of the roofing or waterproofing system, the preparation and approval of the details and shop drawings, or for determining their suitability for a particular project or application. The architect, consultant and/or engineer or design professional for a particular project bears the sole responsibility for the design of the roofing or waterproofing system, for the preparation of the specifications, the preparation and approval of the details and shop drawings, and for determining their suitability for a particular project or application. SIKA MAKES NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, AS TO THE CONTENTS OF THESE GUIDE SPECIFICATIONS. SIKA SHALL NOT BE RESPONSIBLE UNDER ANY LEGAL THEORY TO ANY THIRD PARTY FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING FROM THE USE OF THESE GUIDE SPECIFICATIONS. February 2023 9 ESEVALOTION IN IMES Evaluation Report ESR-1157 Reissued September 2019 This report is subject to renewal September 2021. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE 3.2 Materials: PROTECTION 3.2.1 Sarnafil S327 Single-Ply Membrane: The Sarnafil Section:07 54 00—Thermoplastic Membrane Roofing S327 membrane is a polyester reinforced PVC membrane Section:07 5419—Polyvinyl-Chloride Roofing complying with ASTM D4434 as Type III, and available REPORT HOLDER: with or without a factory-applied felt backing. The Sarnafil S327 is manufactured in four thicknesses. See Table 4 for SIKA SARNAFIL,INC. thicknesses and weights of the membranes with and without the felt backing.The membrane is reinforced with a EVALUATION SUBJECT: polyester scrim. Sarnafil S327 is intended for installation over foam plastic insulation when attached with SARNAFIL S327, G410, G410 SAM, SIKAPLAN mechanical fasteners described in Section 3.2.9 and FASTENED AND SIKAPLAN ADHERED SINGLE-PLY Table 2. ROOFING SYSTEMS 3.2.2 Sarnafil S327 Textured Single-Ply Membrane: The Sarnafil S327 Textured membrane is a polyester 1.0 EVALUATION SCOPE reinforced PVC membrane complying with ASTM D4434 Compliance with the following codes' as Type III. The textured surface is the weather surface. The Sarnafil S327 Textured membrane is manufactured in ■ 2018, 2015, 2012, 2009 and 2006 International Building three thicknesses. See Table 4 for thicknesses and Code®(IBC) weights of the membranes. The membrane is reinforced ■ 2018, 2015, 2012, 2009 and 2006 International with a polyester scrim. Sarnafil S327 Textured membrane Residential Code®(IRC) is intended for installation over foam plastic insulation when attached with mechanical fasteners described in Properties evaluated: Section 3.2.9 and Table 2. ■ Weather resistance 3.2.3 Sarnafil G410 Single-Ply Membrane:The Sarnafil ■ Wind uplift resistance G410 membrane, typically used in adhered systems, is a glass fiber—reinforced PVC membrane complying with ■ Roof covering fire classification ASTM D4434 as Type Il, and is available with or without ■ Impact resistance factory-applied felt backing. The Sarnafil G410 is manufactured in four thicknesses. See Table 4 for 2.0 USES thicknesses and weights of the membranes with and The Sarnafil S327, G410, G410 SA, Sikaplan Fastened without the felt backing. The fiberglass reinforcement is and Sikaplan Adhered Single-Ply Roofing Systems are arranged in a woven mat. Sarnafil G410 is intended for used as classified roof covering assemblies. installation over insulation when fully adhered to the substrate using proprietary adhesives as described in 3.0 DESCRIPTION Section 3.2.10 and Table 3. 3.1 General: 3.2.4 Sarnafil G410 Textured Single-Ply Membrane: The Sarnafil Single-Ply Roofing Systems consist of single- The Sarnafil G410 Textured membrane, typically used in ply reinforced thermoplastic membranes constructed with adhered systems, is a glass fiber-reinforced PVC reinforced poly(vinyl chloride)(PVC). The systems can be membrane complying with ASTM D4434 as Type II. The installed over various types of roof decking, including textured surface is the weather surface.The Sarnafil G410 wood, steel and concrete surfaces. The systems are either Textured membrane is manufactured in three thicknesses. adhered, mechanically fastened or a combination of See Table 4 for thicknesses and weights of the mechanically fastened and adhered to resist wind uplift. membranes. The fiberglass reinforcement is arranged in a Samafil membranes are manufactured in rolls 3.25, 5, 6.5 woven mat. Sarnafil G410 Textured membrane is intended and 10 feet wide (914, 1520, 1980 and 3050 mm) with for installation over insulation when fully adhered to the lengths from 65.6 to 100 feet (20 to 30.5 m). The substrate using proprietary adhesives as described in membranes are typically manufactured with a white Section 3.2.10 and Table 3. weathering surface and a grey underside. However, 3.2.5 Sarnafil G410 SAM Single-Ply Membrane: The custom pigments are available upon request. Sarnafil G410 SAM, used in adhered systems, is a ftw£e►ved .luN 16 z0z3 ICC-ES Eval ation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed 40� vt)'< I / l as an endorsement of the subject of tie report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as if b V to anyfnnding or other matter in this report,or as to any product covered by the report. i•. , Copyright©2019[CC Evaluation Service,LLC. All rights reserved. Page 1 of 10 ESR-1157 1 Most Widely Accepted and Trusted Page 2 of 10 reinforced PVC membrane complying with ASTM D4434 insulation) to combustible or noncombustible roof decks. as Type It. The Samafil G410 SAM is manufactured in The Sikaplan Fastener #14 has a shank diameter of three thicknesses. See Table 4 for thickness and weights 0.190 inch (4.8 mm) and thread diameter of 0.245 inch of the membranes. The fiberglass reinforcement is (6.2 mm). arranged in a woven mat. The membrane has a pressure 3.2.9.4 Sarnafastener XP:The Sarnafastener XP is used sensitive adhesive backing with a release liner. Sarnafil G410 SAM is intended for installation over insulation fully with the Samadisc, described in Section 3., de r attach insulation, and with the Sarnadisc XPN, de adhered to the substrate as described in Table 3. scribed in Section 3.2.9.9, or the Sarnarail Polymer Batten, described 3.2.6 Sikaplan Fastened Single-Ply Membrane: The in Section 3.2.9.12, to attach the membrane (through the Sikaplan Fastened membrane is a polyester reinforced insulation) to combustible or noncombustible roof decks. PVC membrane complying with ASTM D4434 as Type III, The Sarnafastener XP has a shank diameter of 0.21 inch and available with or without a factory-applied felt backing. (5.3 mm)and thread diameter of 0.26 inch(6.6 mm). The Sikaplan Fastened membrane is manufactured in two 3.2.9.5 Sarnafastener MAXLoad: The Sarnafastener thicknesses. See Table 4 for thicknesses and weights of MAXLoad is used to attach the Sarnafil membrane with the the membranes with and without the felt backing. The Sarnadisc MAXLoad, described in Section 3.2.9.10, or membrane is reinforced with a polyester scrim. Sikaplan Sarnarail Polymer Batten, described in Section 3.2.9.12,to Fastened is intended for installation over foam plastic steel or combustible decks. The Sarnafastener MAXLoad insulation as indicated in Table 1 when attached with has a shank diameter of 0.26 inch (6.6 mm)and a thread mechanical fasteners described in Section 3.2.9 and Table 2. diameter of 0.33 inch(8.4 mm). 3.2.7 Sikaplan Adhered Single-Ply Membrane: The 3.2.9.6 Sarnaplate: The Sarnaplate is a 3-by-3-inch 3.2 Adhered membrane, (76 mm by 76 rnm), No. 26 gage [0.018 to 0.021 inch Sikaplantypically used in adhered (0.45 to 0.53 mm) base-metal thickness], AZ 55 systems, is a glass fiber-reinforced PVC membrane Galvalume-coated plate. complying with ASTM D4434 as Type II, and is available with or without factory-applied felt backing. The Sikaplan 3.2.9.7 Sarnadisc: The Sarnadisc is a 3-inch-diameter Adhered membranes are manufactured in two (76 mm), No. 26 gage [0.018 to 0.021 inch (0.45 to thicknesses. See Table 4 for thicknesses and weights of 0.53 mm)base-metal thickness], AZ 55 Galvalume-coated the membranes with and without the felt backing. The plate. fiberglass reinforcement is arranged in a woven mat. 3.2.9.8 Sarnadisc 23/a: Sarnadisc 23/e is 23/e-inch Sikaplan Adhered is intended for installation over (60 mm) diameter, 0.037-inch (0.94 mm) thick plate insulation that is attached to roof decks as indicated in stamped from Galvalume AZ 50 or AZ 55 steel. It has six Table 1 when fully adhered to the substrate using equally spaced "v" protrusions punched through proprietary adhesives as described in Section 3.2.10 and concentrically at 19/32-inch (15 mm) from the center of the Table 3. plate. 3.2.8 Foam Plastic Insulation: Foam plastic insulation, 3.2.9.9 Sarnadisc XPN: The Sarnadisc XPN is a V/2-by- where used,must have a flame-spread index of not greater 33/4-inch (38 by 95 mm), No. 18 gage [0.040 to 0.042 inch than 75 when tested, at the maximum thickness intended (1.00 tol.05 mm)base-metal thickness],A7_55 Galvalume- for use, in accordance with ASTM E84 or UL 723. See coated plate. Tables 1, 2 and 3 for insulations recognized for use with the respective roofing systems. 3.2.9.10 Sarnadisc MAXLoad: The Sarnadisc MAXLoad is a 3.5-inch-diameter (89 mm), No. 20 gage [0.031 to 3.2.9 Mechanical Fasteners: Substrate, fastener and 0.041 inch (0.78 to 1.02 mm)base-metal thickness],AZ 55 plate combinations must be as outlined in the Galva lume-coated plate. manufacturer's published installation instructions and Table 2 of this report. 3.2.9.11 Sarnadisc RhinoBond: Samadisc RhinoBond is a 3-inch (75 mm) diameter, 0.028-inch (0.7 mm) thick 3.2.9.1 Sarnafastener #12; The Sarnafastener #12 is metal plate coated with a polymer coating used in used with the Sarnaplate, described in Section 3.2.9.6, to conjunction with the RhinoBond induction welder to attach attach insulation boards to steel or combustible roof decks. the membrane. Sarnafastener#12 has a modified buttress thread, a shank diameter of 0.168 inch (4.3 mm) and a thread diameter of 3.2.9.12 Sarnarail Polymer Batten: The Sarnarail 0.214 inch(5.4 mm). Polymer Batten is a 1-inch-wide-by-250-foot-long-by-l/20- inch-thick(25 mm by 762 m by 1.27 mm)modified polymer 3.2.9.2 Sarnafastener #14: The Sarnafastener #14 is batten. The batten, manufactured in coils, has holes used with the Sarnaplate, described in Section 3.2.9.6, to spaced 6 inches (152 mm) on center and is used with attach insulation, and with the Sarnadisc XPN,described in either the Sarnafastener XP or the MAXLoad fasteners, Section 3.2.9.9, or the Samadisc RhinoBond, described in described in Sections 3.2.9.4 or 3.2.9.5, respectively, for Section 3.2.9.11, or the Sarnarail Polymer Batten, securing the roof membrane. described in Section 3.2.9.12 to attach the membrane (through the insulation) to combustible or noncombustible 3.2.10 Adhesives: roof decks. The Sarnafastener#14 has a shank diameter 3.2.10.1 Sarnacol 2170: Sarnacol 2170 is a solvent-based of 0.190 inch (4.8 mm) and thread diameter of 0.245 inch adhesive for bonding Sarnafil membranes to foam plastic (6.2 mm). substrates or Georgia-Pacific LLC DensDeck Roofboard 3.2.9.3 Sikaplan Fastener #14: The Sikaplan Fastener with application rates as specified in Table 3. Samacol #14 is used with the Sarnaplate, described in Section 2170 is supplied in 5-gallon (18.9 L) steel containers. The 3.2.9.6, to attach insulation, and with the Samadisc 23/8, shelf life is one year when the adhesive is stored in the described in Section 3.2.9.8, Sarnadisc XPN, described in original unopened container at temperatures between 40"F Section 3.2.9.9, Samadisc RhinoBond, described in and 80"F(4.4"C and 26.7"C). Section 3.2.9.11, or Sarnarail Polymer Batten, described 3.2.10.2 Sarnacol 2170 VC: Sarnacol 2170 VC is a in Section 3.2.9.12, to attach the membrane (through the solvent-based adhesive used for bonding Samafil ESR-1157 I Most Widely Accepted and Trusted Page 3 of 10 membranes to foam plastic substrates or Georgia-Pacific systems. The systems must be installed at the maximum LLC DensDeck® Roof Board with application rates as slope specified in Table 1. specified in Table 3. Samocol 2170 VC is supplied in 4.3 Wind Resistance: 5-gallon (18.9 L)steel containers.The shelf life is one year when the adhesive is stored in the original unopened See Tables 2 and 3 for a full description of components, container at temperatures between 40°F and 80'F (4.4°C fastener spacing, adhesive application and allowable and 26.7°C). design wind uplift pressures for each of the evaluated 3.2.10.3 Sarnacol 2121: Sarnacol 2121 is a water-based systems. adhesive for bonding Sarnafil membranes to foam plastic 4.3.1 Metal Edge Securement Systems: Metal edge substrates or Georgia-Pacific LLC DensDeck® Roof Board securement systems must be listed in accordance with the with application rates as specified in Table 3. Samacol 2011 edition of ANSI/SPRI/FM 4435 ES-1, and designed 2121 is supplied in 5-gallon (18.9 L) steel containers. The and installed for wind loads in accordance with 2018 and shelf life is one year when the adhesive is stored in the 2015 IBC Section 1504.5 and 2018 and 2015 IBC Chapter original unopened container at temperatures between 40°F 16 [2003 edition of ANSI/SPRI/FM 4435 ES-1, and and 80°F(4.4°C and 26.7°C). designed and installed for wind loads in accordance with 3.2.10.4 Samacol AD Feltback Membrane Adhesive: 2012, 2009 and 2006 IBC Section 1504.5 and 2012, 2009 and 2006 IBC Chapter 16]. Sarnacol AD Adhesive is a two-part liquid applied non- asphaltic urethane adhesive that transforms into a low rise 4.4 Flashing: foam during the curing process.The adhesive is packaged Flashing must be provided as required by IBC Section in 0.16-gallon (600 mL) cartridges, four to a box or 1503.2.1 or IRC Section R903.2.1, as applicable. Where 10-gallon (37.8 L)box sets consisting of two parts: (Part 1 flashing is of metal, the metal must be corrosion-resistant - 5-gallon (18.9 L) and Part 2 - 5-gallon (18.9 L)). The with a thickness of not less than No. 26 gage[base-metal shelf life is 18 months when the adhesive is stored in the thickness of 0.019 inch(0.5 mm)]. original unopened container at temperatures between 45°F and 95°F(7°C and 35°C). 4.5 Reroofing: 3.2.10.5 Sarnacol OM Feltback Membrane Adhesive: The existing deck must be inspected to verify that the Sarnacol OM Adhesive is a two-part low rise polyurethane structure to be reroofed is structurally sound and adequate adhesive that is applied in one step, dispensed at a 1:1 to support and secure the roofing membrane. Prior to ratio. The adhesive is packaged in 0.16-gallon (600 mL) installation of new roof coverings, inspection by, and cartridges, four to a box or 10-gallon (37.8 L) box sets written approval from, the code official having jurisdiction consisting of two parts: (Part 1 -5-gallon(18.9 L)and Part are required in accordance with 2018 and 2015 IBC 2-5-gallon (18.9 L)).The shelf life is 18 months when the Section 1511 [2012, 2009 and 2006 IBC Section 1510]. adhesive is stored in the original unopened container at The roof covering systems described in this report, temperatures between 55°F and 857 (12.8°C and installed over an existing roof covering system, must be 29.5°C). shown to satisfy classification requirements by testing of the composite system in accordance with ASTM E108 or 3.2.11 Barrier Board: Barrier board, where used, must be UL 790. As an alternative, Class A, B or C roof covering a minimum of 1/4-inch (6.4 mm) DensDeck® Roof Board systems are permitted to be installed over existing manufactured by Georgia-Pacific LLC classified roof covering systems under the following 3.3 Impact Resistance: conditions without additional roof classification tests, provided the resulting classification is the lower of the The Sarnafil S327 and G410 Single-Ply Roofing Systems classification for the new and existing roofing: described in this report comply with the requirements for impact resistance in accordance with Section 4.6 of • New uninsulated systems installed only over existing FM 4470. uninsulated assemblies. 4.0 INSTALLATION • New insulated systems installed only over existing uninsulated system 4.1 General: 5.O CONDITIONS OF USE Installation of the Sarnafil S327, G410, G410 SAM, Sikaplan Fastened and Sikaplan Adhered Single-Ply The Sarnafil S327, G410, G410 SAM, Sikaplan Fastened Roofing Systems must comply with the applicable code, and Sikaplan Adhered Single-Ply Roofing Systems this report and the manufacturer's published installation described in this report comply with, or are suitable instructions. The manufacturer's published installation alternatives to what is specified in, the codes indicated in instructions must be available at the jobsite at all times Section 1.0 of this report, subject to the following during installation. The substrate must be smooth, dry, conditions: clean and free of sharp projections, loose fasteners, 5.1 Installation must comply with this report, the protrusions, depressions or contaminants that might manufacturer's published instructions and the interfere with the adhesion or attachment of the applicable code. If there is a conflict between the membrane.Any surface defects must be corrected prior to manufacturer's published installation instructions and the membrane installation.All materials must be protected this report,this report governs. against contact with incompatible materials. The roof 5.2 The Sarnafil S327, G410, G410 SAM, Sikaplan systems must not be installed on roofs having slopes less Fastened and Sikaplan Adhered Single-Ply Roofing than /4:12(2 percent slope)or more than that specified for Systems must be installed by a Sarnafil, Inc., trained the particular assembly as listed in Table 1 for the and approved contractor. Evidence of this approval corresponding assembly and roof classification. must be made available to the code official upon 4.2 Roof Covering Classification: request. See Table 1 for a full description of components and the 5.3 Design wind uplift pressures on any roof area, roof covering classification for each of the evaluated including edge and comer zones, must not exceed BUILDING TRUST PRODUCT DATA SHEET SikaplanO Fastened-60 EnergySmart 60 mil thick PVC thermoplastic membrane PRODUCT DESCRIPTION CHARACTERISTICS/ADVANTAGES Sikaplan®Fastened-60 EnergySmart Roof Membrane is a PVC thermoplastic membrane produced with a polyester scrim reinforcement. � Zer������ USES Roof Mechanically attached using various attachment • Highly reflective components over approved substrates.It may also be • Excellent tear strength resistance used in adhered applications to approved substrates. • Factory applied lacquer coating to reduce dirt pick up • Hot-air welded seams for long-term performance AREAS OF APPLICATION APPROVALS/STANDARDS • In-seam disc systems • In-seam batten,double-weld systems FM Global] • RhinoBond®systems Underwriters Laboratories • Adhered systems • Underwriters Laboratories of Canada • New construction and reroofing ICC Code Compliance—ESR 1157 • Miami-Dade County • Florida Building Code • California Title 24 • LEED/Green Globes ]Mechanically attached only. Product Data Sheet vV �tjtA Sikaplan•Fastened-60 EnergySmart e September 2022,Version 07 01 020905011050153002 JUN y �p 2023 1/4 PRODUCT INFORMATION Chemical Base Thermoplastic PVC membrane containing ultraviolet light stabilizers,flame retardant and polyester scrim reinforcement with a unique lacquer coating on the top surface. Recycled Content 9%Pre-consumer, 1%Post-consumer Reinforcing Material Polyester Packaging 60 mil(1.5 mm)Membrane 10 ft x 100 ft(3 m x 30 m)roll,343 Ibs(156 kg)per roll, 8 rolls per pallet 5 ft x 100 ft(1.5 m x 30 m)roll,172 Ibs(78 kg)per roll, 12 rolls per pallet Shelf Life N/A Storage Conditions Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins.Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability. Appearance/Color • Top:White,Reflective Gray,and Tan • Bottom:Gray Overall Thickness 60 mil(1.5 mm),nominal (ASTM D-751) 45 mil (ASTM Type III D-4434 Spec.Requirement) Thickness Above Scrim 24 mil (ASTM D-7635) 16 mil (ASTM Type III D-4434 Spec.Requirement) TECHNICAL INFORMATION Resistance to Static Puncture Pass (ASTM D-5602) 33 Ibf(15 kg) (ASTM Type III D-4434 Spec.Requirement) Resistance to Dynamic Puncture Pass (ASTM D-5635) 14.7 ft-Ibf(20 J) (ASTM Type III D-4434 Spec.Requirement) Tensile Strength 303 Ibf(1348 N) (ASTM D-751) 200 Ibf(890 N) (ASTM Type III D-4434 Spec.Requirement) Elongation at Break 20&20%MD&CMD1 (ASTM D-751) 15&15%MD&CMD1 (ASTM Type III D-4434 Spec.Requirement) 1 MD=Machine Direction,CMD=Cross Machine Direction. Tear Strength 45 Ibf(200 N) (ASTM D-751) 45 Ibf(200 N) (ASTM Type III D-4434 Spec.Requirement) Seam Strength Pass (ASTM D-751) 75%of original2 (ASTM Type III D-4434 Spec.Requirement) 2 Failure occurs through membrane rupture not seam failure. Linear Dimensional Change 0.24% (ASTM D-1204) 0.5% (ASTM Type III D-4434 Spec.Requirement) Product Data Sheet Sikaplan°Fastened-60 Energy5mart September 2022,Version 07 01 020905011050153002 BUILDING TRUST 2/4 Solar Reflectance EnergySmart Colors Initial Solar 3-Year Solar Reflectance' _ Reflectance' EnergySmart 0.85 0.75 White _ EnergySmart 0.73 0.66 Reflective Gray EnergySmart 0.72 0.65 Tan 'Solar Reflectance testing according to ASTM C-1549. Solar Reflectance Index EnergySmart Colors Initial Solar 3-Year Solar Reflectance Index' Reflectance Index' EnergySmart 107 93 White EnergySmart 90 80 Reflective Gray EnergySmart 88 78 Tan 1 Solar Reflectance Index calculated according to ASTM E-1980. Thermal Emittance EnergySmart Colors Initial Thermal 3-Year Thermal Emittancel Emittance' EnergySmart 0.89 0.90 White EnergySmart 0.89 0.88 Reflective Gray EnergySmart 0.89 0.88 Tan 1 Thermal Emittance testing according to ASTM C-1371,Slide Method. Low Temperature Bend Pass (ASTM D-2136) Pass-40oF(-40oC) (ASTM Type III D-4434 Spec.Requirement) Weight Change after Immersion in Water 2.5% (ASTM D-570) +3 0% (ASTM Type III D-4434 Spec.Requirement) UV Exposure 10,000 hours (ASTM G-154) 5,000 hours (ASTM Type III D-4434 Spec.Requirement) Cracking None (7x magnification) Discoloration Negligible (by observation) Crazing None (7x magnification) Retention of Properties after Heat Ageing Tensile Strength,%of original: Pass (ASTM D-3045) Elongation,%of original:Pass (ASTM D-751) Tensile Strength,%of original:90 (ASTM Type III D-4434 Spec.Requirement) Elongation,%of original:90 BASIS OF PRODUCT DATA AVAILABILITY/WARRANTY Results may differ based upon statistical variations AVAILABILITY depending upon mixing methods and equipment, temperature,application methods,test methods,actual From Sika Corporation—Roofing Authorized Applicators site conditions and curing conditions. for use within Sarnafil or Sikaplan systems. Product Data Sheet Sikaplan'Fastened-60 EnergySmart September 2022,Version 07.01 020905011050153002 BUILDING TRUST A& 3/4 LEGAL DISCLAIMER WARRANTY •KEEP CONTAINER TIGHTLY CLOSED •KEEP OUT OF REACH OF CHILDREN Upon successful completion of the installed roof by the .NOT FOR INTERNAL CONSUMPTION Sika Authorized Applicator in compliance with Sika •FOR INDUSTRIAL USE ONLY requirements,Sika Corporation will provide a warranty .FOR PROFESSIONAL USE ONLY to the Building Owner via the Sika Authorized Applicator. ENVIRONMENTAL HEALTH AND SAFETY Prior to each use of any product of Sika Corporation,its subsidiaries or affiliates("SIKA"),the user must always read and follow the warnings and instructions on the For further information and advice regarding product's most current product label,Product Data transportation,handling,storage and disposal of Sheet and Safety Data Sheet which are available at chemical products,user should refer to the actual Safety usa.sika.com or by calling SIKA's Technical Service Data Sheets containing physical,environmental, Department at 1-800-933-7452.Nothing contained in toxicological and other safety related data. User must any SIKA literature or materials relieves the user of the read the current actual Safety Data Sheets before using obligation to read and follow the warnings and any products.In case of an emergency,call CHEMTREC instructions for each SIKA product as set forth in the at 1-800-424-9300,International 703-527-3887. current product label, Product Data Sheet and Safety APPLICATION INSTRUCTIONS Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of APPLICATION installation to be free from manufacturing defects and Sikaplan Fastened is installed on acceptable substrates to meet the technical properties on the current Product and fastened to the roof deck usingthe a Data Sheet if used as directed within the product's shelf ons,the life. User determines suitability of product for intended attachment method. In adhered applications,the use and assumes all risks.User's and/or buyer's sole membrane is unrolled into approved Sikaplan or Sarnacol adhesive in accordance with Sika's technical remedy shall be limited to the purchase price orreplacement of this product exclusive of any labor costs. requirements and then pressed into place with a NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL minimum 75 lb(34 kg)steel roller.The membrane is APPLY INCLUDING ANY WARRANTY OF heat-welded together by trained mechanics using hot-air MERCHANTABILITY OR FITNESS FOR A PARTICULAR welding equipment.Sikaplan Fastened can be used for PURPOSE.SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL fleshings on Sikaplan Fastened and Sikaplan Adhered THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. roof projects. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS MAINTENANCE PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD Standard maintenance of Sikaplan systems should BY OTHERS. include regular inspections of flashings,drains and Sale of SIKA products are subject to the Terms and terminations sealants at least twice a year and after Conditions of Sale which are available at each storm. https://usa.sika.com/en/group/SikaCorp/termsandconditions.htmi OTHER RESTRICTIONS or by calling 1-800-933-7452. See Legal Disclaimer. Slka Corporation 201 Polito Avenue Lyndhurst,NJ 07071 Phone:+1-800-933-7452 Fax:+1-201-933-6225 usa sika.mm SikaplanFastened-60Energy5mart-en-US-(09-2022)-7-1 pdf Product Data Sheet Sikaplan*Fastened-60 EnergySmart September 2022,Version 07 01 020905011050153002 4/4 BUILDING TRUST v Q a c c Q uj GJ w w 3 c o o m o cwe o io is cc 5 Y n c0 C.) U U V U E U O. U _ J J L$ Q J Q m > > o m 3 z - N W — - w J J W_c-c E > > c O c N _m T Eo Eo y c c °� Eo �1 L GD f- V Y S. :L••,d y •y M U •.L.. C V \ 1�I W N 3: 3 � m x x O R u ¢ o Q p m m o. Q L o: c c ¢ o ¢ w dy O c Q v c' ca v rn z L'v z vcr cc = CA J J J J-� w w c O y O �� ca cc c cv ,+ c� Q m E o E o = l ) G1 L L d w co c0 C cd VV rn E � t CD to 3 Y 3 > U O O Q a 0 ¢ O •Q d G w w G w 0 U U G J J co a T w m w n ¢ ¢ Q o- ¢ o T E o wrn 5Im o o o o voi w j U_ U_ Z Z Z U Z C O w LL j� _� J �\ cp C 7 m w c0 U ` rVl o f o` cu Q Q o o Q w m w U O av+ o twn id id w o o U w (d O� 3 C.) U U L 1 Z n76 J CLA p U U _. O O J J o m m E > O .6cc -0 -3 `o� •3 o a y c c ¢ Q ¢ m a W u_ O1 ¢m ca ¢m o U y w h �' ca w `° c� c w m a v, m x x c" cc m 5 n E aoi o W s Y _cc co w= a5 � ai y V U ¢ U v'y oo Um Q A ca O O o O c c L o O Q x x 3 V w — `L vi o w fO = wcc m wm U o �+w a L) E w O.= E d in =� O w U w Q U O U O d G OJ L U'[/) -a m m U d U T J U J U Q Q C N E;)t d y c0 Q LL 3 z z in Ew m a E E z CD` O Q Q Q Q Q Q �pFD w co co Vf o 0 0 co o 0 c ? c0 C.> V C O U U U U _ O O J_ J J Z 1 w w (n m Em OJ o o N o y ^ c t a� a� w U U I a o v, o. U w d J J co C S C (A C Q` c0 w cd �• C C wcl w w O co y ,_ O O w VJ of w w L w _T L L L L U x X O 3 ca•� a 3 Cn m o W V Qo ¢ o t c c Q w m Cl V L t eo _ c E 'o N cc V U U Q a[ 2 --I o 0 E cc C� J J w Z U U w U L c6 O. • • w0 O L_ -- J awo n o ccu _ Jca oQ � Q � o 3+ o d d w� wa fw.) o TN co cY_a N E h y wn coi ca y -a o � o � •n n ncc`dcw ym� m m � m G O O E T J U J U Q ¢ 5 E y d 'a E X J J L J W I— E E a ca LL 3 3 z z inw caa E � (j} _ • o E w L a - - 3 c d o z cD E — 0 3 0 0 3 �_ E w c� a U O '~ L fA T C L � O_ C d cu CD C QJ C a1 w W N O.Q w ++ O y+ m c ccv o 0 0-in l E L co 0\ '�. y cn+ /�3 3 o p- ea �°-'�' co w ca a� " E w C. n J " w a I Yl w L ® O p w w m T LL. '� N 3 V y d E LL E a' > >' N w c C E LL c E O U. c m c s w w p c y a rn a Y ` cam y .o '.°- mcc'o LSE ' C� E, c°.� I + Coc � cwci '�o a W y +L.-• W tL c C o c 1L m N o H •` LL w co.+ _ a LL w o o a cEp .J 3 d y 0 d a 7 `p L ~ N E p m , W 0 ~E O Y C p w w N O L Q C .^i w O c0 U L C E Q] a w C O E T CL L C � w O � - t U N O LL cocL a O O �- c) w cis F- a co O a`� E E w y d w u 1 ~ w o w o CL w c° T - N - O_ L cL CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 20500 OLYMPIC PL Permit#: 5421 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00847300000800 DATE OF ISSUANCE. Scope of Work: Install flute fill,cover board and new single ply membrane over Valuation: 377648.00 existing metal roof. OWNER APPLICANT CONTRACTOR SAFEWAY INC, STORE#1522 Nations Roof Mountain,LLC. Nations Roof Mountain,LLC PO BOX 800729 10621 W.Executive Dr. 10621 W.Executive Dr. DALLAS,TX 75380 Boise,ID 83713 Boise,ID 83713 208-322-2474 208-322-2474 LIC:604 316 862 EXP:04/30/2024 LIC:NATIORM828P6 EXP: 12/10/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL RE-ROOF CODE YEAR: STORIES: 1 CONST.TYPE: 1113 DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 07/07/2023 Applicant Signature Date Building Official Date CONDITIONS APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.ADHERE TO APPROVED DOCUMENTS.CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/07/2023 Web Only-Re-Roof Commercial Plan Review $100.00 07/07/2023 Processing/Technology $25.00 07/07/2023 State Surcharge-Commercial $25.00 07/07/2023 Re-Roof Commercial $3,832.76 Total Due: $3,982.76 Total Payment: $3,982.76 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail 7/10/23,4:50 PM iworq.net/iworq/O_Pages/Permit/popupLetterExternal.php?id=20327925&fid=605&accountid=1046&letterid=18103857 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 20500 OLYMPIC PL Permit#: 5421 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00847300000800 DATE OF ISSUANCE. Scope of Work: Install flute fill,cover board and new single ply membrane over Valuation: 377648.00 existing metal roof. OWNER APPLICANT CONTRACTOR SAFEWAY INC, STORE#1522 Nations Roof Mountain,LLC. Nations Roof Mountain,LLC PO BOX 800729 10621 W. Executive Dr. 10621 W.Executive Dr. DALLAS,TX 75380 Boise,ID 83713 Boise,ID 83713 208-322-2474 208-322-2474 LIC:604 316 862 EXP:04/30/2024 LIC:NATIORM828P6 EXP: 12/10/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL RE-ROOF CODE YEAR: STORIES: 1 CONST. TYPE: 1113 DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I O/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. • �G�i 07/07/2023 Applicant Signa a qpte Building Official Date CONDITIONS APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.ADHERE TO APPROVED DOCUMENTS.CALL FOR INSPECTIONS. httDS://www.iwora.net/iwora/0 PAOPS/PPrmlt/nnnnnl ottorPytornni nhn9irL�11z97o�Gtt.fi-anaa ;a—�nnco u _:a_,o,����� ., 7/10/23,4:50 PM iworq.net/iworq/0_Pages/Permit/popupLetterExternal.php?id=20327925&fid=605&accountid=1046&letterid=18103857 THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/10/2023 Web Only-Re-Roof Commercial Plan Review $100.00 07/10/2023 Processing/Technology $25.00 07/10/2023 State Surcharge-Commercial $25.00 07/10/2023 Re-Roof Commercial $3,832.76 Total Due: $3,982.76 Total Payment: $3,982.76 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail httDS://www.iworn_net/iwnrn/o PgnPC/PPrmlt/nnnnnl ottorFvtornni nhn9irl=JnQ9709GQ.f -RnG4_ +:a-4necoi u _�eennnc� Permit#: 5421 Permit Date: 06/16/23 Permit Type: COMMERCIAL RE-ROOF Project Name: Safeway#1522 Applicant Name: Nations Roof Mountain, LLC. Applicant Address: 10621 W. Executive Dr. Applicant, City, State, Boise, ID 83713 Zip: Contact: Jordan Williams Phone: 208-322-2474 Email:jwilliams@nationsroof.com Scope of Work: Install flute fill, cover board and new single ply membrane over existing metal roof. Valuation: 377648.00 Square Feet: 44100 Number of Stories: 1 Construction Type: 11B Occupancy Group: B; Business ID Code: Permit Issued: 07/10/2023 Permit Expires: 01/06/2024 Form Permit Type: COMMERCIAL RE-ROOF Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00847300000800 20500 OLYMPIC PL SAFEWAY INC, 630 RETAIL STORE#1522 Contractors Contractor Primary Contact Phone Address Contractor Type License License# Nations Roof Mountain, 208-322-2474 10621 W. CONSTRUCTION COA 604 316 862 LLC Executive Dr. CONTRACTOR Nations Roof Mountain, 208-322-2474 10621 W. CONSTRUCTION L&I NATIORM828P6 LLC Executive Dr. CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/29/2023 Inspection final 10/02/2023 10/09/2023 BUILDING Approved Plan Reviews Date Review Type Description Assigned To Review Status 06/16/2023 COMMERCIAL RE-ROOF BUILDING Approved Fees Fee Description Notes Amount Web Only-Re-Roof Commercial Plan Enter 1 if permit is for commercial re-roof $100.00 Review Processing/Technology $25.00 State Surcharge-Commercial Commercial Only $25.00 Re-Roof Commercial Table 4.1 $3,832.76 Total $3,982.76 Attached Letters Date Letter Description 07/07/2023 Building Permit 06/16/2023 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/19/2023 XBP Conf: $3,982.76 147220281 Outstanding Balance $0.00 Notes Date Note Created By: 10/09/2023 received pictures from contractor that the building official requested to complete the inspection Hannah Hardwick on the roof.Forwarded to Building Official for review. 07/11/2023 Emailed the permit for signature. Kristin Foster Uploaded Files Date File Name 07/12/2023 16118636-20230710 BLD5421 IssuedPermit.pdf 07/12/2023 16118634-20230705 BLDL21 ApprovedDocs.pdf 06/16/2023 565b84ee6d416aab9eel88bbc69b39b2 arlington building_permit app.pdf 06/16/2023 4f4a624lc399d7b3ef8261ca2e01770d sikaplan fastened-60energysmart.pdf 06/16/2023 cic052734ce7de76052c582d695c2la9 ul insulation.pdf 06/16/2023 f8dcfed731356917bac54flafdOc2047 icc-esr-1157 sikaplan fastened.pdf