HomeMy WebLinkAbout18308 35th Ave Ne_BLD5350_2026 s FIRE ALARM PERMIT APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 •Phone(360)403-3551 Type of Permit: ❑ New Installation 21 System Modification ❑ Phased Installation 18308 Smokey Point Blvd. N/A 8500.00 Property Address: Suite No.: Project Valuation: Lot#: NIA Parcel ID No.: 00472500000601 Preferred Contact: 0 Owner 71 Applicant 0 Contractor Project Description: Install'like for like" replacement fire alarm panel in place of existing fire alarm panel. Install AES radio for fire alarm panel monitoring at the library building. Owner Name: Stilly Valley Center-Library Building Phone No.: 360-653-4551 ext. 230 Email Address: dklemens@stillycenter.org Cell No.: N/A Mailing Address: 18308 Smokey Point Blvd. City: Arlington State: WA. Zip: 98223 Applicant Name: Erik Barker Phone No.: 206-284-1721 Email Address: erik@aaafire.com Cell No.: 206-595-1716 Mailing Address: 3013 3rd Ave North city: Seattle State: WA. Zip: 98109 Contractor Name.. AAA Fire Protection Phone No.: 206-284-1721 Email Address: Permits@aaafire.com Cell No.: 206-595-1716 Mailing Address: 3013 3rd Ave North City. Seattle State: WA. zip: 98108 L&I Contractor License Number: AAAFIFP841 N3 Expiration Date: 8-23-2024 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation Submit electronic files of the follow: ❑ Complete and Scaled Plans 0 Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable NOTE: All Central Station Monitoring must be UL or FM listed. FIRE ALARM SYSTEMS (105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Switch, Supervisory Switches, Magnetic Door Hold-Open Devices, Remote Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at time of application submittal Less than $5,000.00 = $100.00 $5,000.00 &over—based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION/PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application -review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour(1 hour minimum) $75.00 ✓Q TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 2 $ 75.00 = $75.00 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FRCP/TRANSMITTER Modification $125.00 = $ 125.00 PERMIT FEE SUBTOTAL $200.00 ❑ NEW COMMERCIAL SYSTEM (NFPA 72) Number of Devices** Device Fee Subtotal 1 to 100 $350.00 = $ 101 to 200 $475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $ PERMIT FEE SUBTOTAL $200.00 PERMIT FEE TOTAL $200.00 PLAN REVIEW FEE $228.73 Processing/Technology Fee $25.00 TOTAL $453.73 1 hereby certify that 1 am the ❑Owner, ❑Applicant Z Contractor,and authorized to sign this application and that the above information is rrect and c s uction on, and the occupancy and the use of the above-described property will be in accordance with the I rules and re 1 tion of the Stat of Washington,and the City ofArlington. Erik Barker 5-9-2023 Signature Print Name Date SAVE PRINT REV2022 Page 2 of 2 aes-corp.com lwr# AESI� CORPORATION 7707 Fire Subscribers .......... IntelliNet0 • A Newer Smarter Alarm Communications Platform Feature Highlights i i• • Leverages state of the art technology • Applies advanced security protection 1 uL E • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes dual communication/multiple communication technology(reporting over RF and IP. • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status.The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop,tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D Subscriber / , I B)Fire 1 i Subscriber 1 / 1 I AES-Network Management System —— B ————————————— ` rosal�D Primary AES-Mul[iNe[Receiver I / I I I A)Alarm Panel Secondary AES-Mull%Net Receiver / I I I B // I B Alarm Automation ------------ C A -- - C)IP Links Customer Location Mesh Radio Technology Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet®Network AE Network routing Primary&Secondary AES-MuldNet System Secondary AES-MuldNet System sends critical event signal delivers alarm signals via smart routin receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board.AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy . • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem IIla2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60oC) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. f in v o AES Corporation • Peabody, ' 01960 United States O Copyright 2022 • •• • • 0 are registered trademarks of • •• 7-h -7 -aj T- r� %Ylt, oz tz, f 7,11 CIA ZZ ............................................ FIRE ALARM • '• PANEL SK-4 & SK-4E Fire Alarm Control Panel 4-zone fire protection at a price that won't burn your budget. 0 0 The SK-4 and SK-4E (SK-4/E) are four zone conventional fire alarm control panels (FACPs)that bring the latest in microprocessor technology to conventional fire controls. The SK-4 is a 120 VAC FACP and the SK-4E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small- to medium-sized commercial, industrial, and institutional buildings. For more information about the SK-4/E system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Support for synchronization of The four zone SK-4/E is a 24 VDC standard ANSI audible signals and FACP that provides four Class B ADA compliant strobes per NFPA 72 initiating device circuits and two Class Selectable for System Sensor, B notification appliance circuit (NAC). Wheelock, and Gentex protocols • Selective silence feature allows The SK-4/E NAC protocol includes the manual silence of horns while strobes ability to silence audible devices while continue to flash on the same NAC strobes continue to flash, using only a Program for combination tamper single pair of wires.The SK-4/E is also supervisory monitor and waterflow compatible with conventional input alarm on one zone devices such as two-and four-wire Silent or audible walk test operation smoke detectors, pull stations, mode waterflow devices, tamper switches and . Alarm verification selectable per zone other normally-open contact devices. . Program each zone for supervisory or Activation of a compatible smoke fire with separate red and yellow detector or any normally-open fire LEDs alarm initiating device activates audible • Disable switches provided per zone SK-4 and visual signaling devices, illuminates . Program NACS for an indicating LED, sounds the piezo —Silence inhibit Initiating Device Circuits (IDCs) sounder at the FACP, activates the —Auto silence Operating Voltage: 22 VDC nominal; FACP alarm relay, and operates an power-limited —Strobe synchronization Standby Current: 4 mA optional module used to notify a remote —Temporal or steady signal Alarm Current: 15 mA min station or initiate an auxiliary control —Silenceable or nonsilenceable Short-circuit Current: 40 mA max function. —Disable Loop Resistance: 1000 max The SK-4/E is compatible with System EOL Resistor: 4.7K Q, 1/2 watt p Y Form C alarm, trouble, and Sensor° 13 detectors providing supervisory relays NACs Signaling Current: 2.5A @ 24 VDC advanced features such as drift • 3A total usable current with standard transformer or 5A compensation, maintenance alert, and 6A total usable current with optional total (2.5A per NAC)with additional freeze warning.Automatic second transformer(PN SK-TRM24 optional transformer, power-limited synchronization of audio/visual devices or SK-TRM24E) EOL Resistor: 4.7K Q, 1/2 watt is provided, using three selections for Optional dress panel (PN SK-DP2/4) Form C Relays manufacturer protocol. Types:Trouble, alarm, and Electrical Specifications supervisory Features SK-4 Primary AC: 120 VAC @ 50/60 Contact Ratings: 2A @ 30 VAC, • Four Style B (Class B) initiating Hz, 2.3A resistive device circuits (IDCs) SK-4E Primary AC: 240 VAC @ 50 Hz, • Two Style Y(Class B) notification 1.15A appliance circuit(NAC) Wiring: 14 AWG (2.0 mm2)with 600 V SILENT • Optional module converts all IDCs insulation min KNIGHT and NACs to Class A(PN SK-CAC4) 0 by Honeywell FIRE ALARM CONTROLPANEL SK-4 & SK-4E Fire Control Panel Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Nbdel SK-4/E.The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices,alarm notification devices,and an on-board annunciator.It shall be compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply,four Class B initiation circuits which shall accommodate heat detectors,smoke detectors, and manual pull stations.Smoke detection shall be achieved with either 2-or 4-wire detectors that are compatible with the system The initiation inputs shall be programmable as 1)verification zones in which detectors are automatically reset one time before signaling an alarm condition;or 2) combination Auterfow supervisory zones that allows the FACP to distinguish between an alarm switch(waterflow,device)and a supervisory switch (tamper)installed on the same circuit.The FACP shall have two 2.5 amp or 5 amp(with an additional optional standard transformer)programmable notification outputs.It shall have dedicated relays for alarm,trouble,and supervisory.It shall have two power outputs,one resettable and one non- resettable,each rated at 500 mA. The FACP shall have an on-board annunciator to indicate alarm,supervisory,trouble,and maintenance conditions.The annunciator must include LEDs for AC,GENERALTROUBLE,ALARMSILENCE,WALKTEST,EARTH FAULT,AND LOWBATTERY.The annunciator shall also contain LEDs to annunciate fire alarms,troubles,supervisory,and maintenance by zone.The FACP must be filly operational from the annunciator and include buttons for ACKNOWLEDGE,ALARM SILENCE,RESET,and WALKTEST.The annunciator must also have separate DISABLE switches for each zone and notification circuit.rr Electrical Specifications (cont) Installation SK-4XTM Auxiliary Output The SK-4/E can be surface mounted Transmitter Module. Provides a Resettable and non-resettable using two key slots at the top of the supervised output for local energy Operating Voltage: 24 VDC nominal backbox and two additional 0.25" municipal box transmitter and alarm Current: 500 mA max, power-limited; diameter holes at the bottom, or semi- and trouble reverse polarity. total current for nonresettable power, flush mounted using the optional Trim resettable power and two NACs must Ring P/N TR-1-R M LED Interface not exceed 6.OA(requires additional LED nterface Module. transformer) Approvals SK-XRM24 NFPA 72; UL Listed; Battery 110 Volt Transformer 3-6A. Type: Sealed lead acid only CSFM 7165-0559: 145; Charging Circuit: 27.6 VDC @ 0.8A MEA 297-01-E-3 SK-XRM24E max normal flat charge Ordering Information 220 Volt Transformer 3-6A. Charging Capacity: 18 AH SK-4 SK-RZA4 Size: 7 AH max allowed in FACP. 120 VAC Four Zone Conventional Remote Annunciator. Larger batteries can housed FACP in an RBB accessory cabinet SK-4XZM Compatible Initiating and NAC SK-4E Zone Relay Module. Devices 240 VAC Four Zone Conventional RBB See SK document PIN 52612. FACP Remote Battery Box Accessory Mechanical Specifications Accessories Cabinet. Use if back up batteries are Cabinet Backbox Dimensions: SK-DP2/4 too large to fit into FACP cabinet. 14.5"W x 15" H x 3" D Dress Panel.Allows access to the Dimensions: 16"W x 10"H x 6"D (36.83 W x 38.10 H x 7.62 D cm) panel controls but restricts access to p Digital Communicator Accessories Cabinet Door: system wiring. 5104B 14.677"W x 15.342" H x 0.375" D (37.28 W x 38.97 H x 0.95 D cm) SK-CAC4 Six-zone fire control communicator Cabinet Color: Red Class A Convertor. Converts Style B 5129 Telephone Requirements: (Class B) IDCs to Style D (Class A) and Four channel slave fire communicator FCC Part 15 and Part 68 approved Style B (Class B) NACs to Style Z Type of Jack: RJ31X (two required) (Class A) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA 0 KNIGHT keep our product information up-to-date and accurate.We cannot cover all FORM#350305 Rev.C 12/06 specific applications or anticipate all requirements.All specifications are by Honeywell subject to change without notice. For more information, contact Silent Knight Copyright©2006 Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800)328-0103, Fax: (763)493-6475. Permit#: 5350 Permit Date: 05/11/23 Permit Type: FIRE ALARM Project Name: Stilly Valley Center- Library Building Applicant Name: AAA Fire Protection Applicant Address: 3013 3rd Ave North Applicant, City, Seattle, WA 98108 State, Zip: Contact: Erik Barker Phone: 206-284-1721 Email: erik@aaafire.com Scope of Work: Install like for like replacement fire alarm panel in place of existing fire alarm panel. Install AES radion for fire alarm panel monitoring at the library building Valuation: 8500.00 Square Feet: 0 Oa Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 11/07/2023 Form Permit Type: Status: IN PROCESS Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning STILLAGUAMISH 230 COMMERCIAL 00472500000601 18308 35TH AVE NE CENTER INC /SERVICES Contractors Contractor Primary Contact Phone Address Contractor Type License License# AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION COA 600 579 238 Inc CONTRACTOR AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION NICET 144554 Inc CONTRACTOR AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION Labor and AAAFIFP841N3 Inc CONTRACTOR Industries CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18308 35TH AVE NE Permit#: 5350 Parcel#: 00472500000601 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: Install like for like replacement fire alarm panel in place of existing Valuation: 8500.00 fire alarm panel.Install AES radion for fire alarm panel monitoring at the library building OWNER APPLICANT CONTRACTOR STILLAGUAMISH CENTER INC AAA Fire Protection AAA Fire Protection,Inc 18308 SMOKEY POINT BLVD 3013 3rd Ave North 3013 3rd Ave NE ARLINGTON,WA 98223 Seattle,WA 98108 Seattle,WA 98109 206-284-1721 206-284-1721 LIC:600 579 238 EXP:04/30/2024 LIC: 144554 EXP:04/01/2026 LIC:AAAFIFP841N3 EXP:08/23/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX N : Sales tax r i to construction and construction materials in the City of Arlington must be reported on your sales t e n fo and cod d City f Arlington#3101. 06/22/2023 0 Applicant rignature a Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans.Call for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/22/2023 Processing/Technology $25.00 06/22/2023 Fire System Plan Review $162.34 06/22/2023 FACP/Transmitter-Replace $125.00 06/22/2023 Fire Alarm System Permit $75.00 06/22/2023 Credit Card Service $11.62 Total Due: $398.96 Total Payment: $398.96 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION IPass/Fail Permit#: 5350 Permit Date: 05/11/23 Permit Type: FIRE ALARM Project Name: Stilly Valley Center-Library Building Applicant Name: AAA Fire Protection Applicant Address: 3013 3rd Ave North Applicant, City, Seattle,WA 98108 State, Zip: Contact: Erik Barker Phone: 206-284-1721 Email: erik@aaafire.com Scope of Work: Install like for like replacement fire alarm panel in place of existing fire alarm panel. Install AES radion for fire alarm panel monitoring at the library building Valuation: 8500.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: B; Business ID Code: Permit Issued: 06/23/2023 Permit Expires: 12/20/2023 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00472500000601 18308 35TH AVE NE STILLAGUAMISH 230 COMMERCIAL CENTER INC /SERVICES Contractors Contractor Primary Contact Phone Address Contractor Type License License# AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION COA 600 579 238 Inc CONTRACTOR AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION NICET 144554 Inc CONTRACTOR AAA Fire Protection, 206-284-1721 3013 3rd Ave NE CONSTRUCTION Labor and AAAFIFP841N3 Inc CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 10/12/2023 FA00.FIRE ALARM Requesting 8:15am 10/16/2023 10/16/2023 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 05/11/2023 FIRE ALARM BUILDING Approved 05/11/2023 FIRE ALARM FIRE Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-2 $162.34 FACP/Transmitter-Replace $125.00 Fire Alarm System Permit NFPA 72- 105.7.3 $75.00 Credit Card Service $11.62 Total $398.96 Attached Letters Date Letter Description 06/22/2023 Building Permit 05/11/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/25/2023 XBP Conf: $387.34 145546900 05/25/2023 145546900 AmeresiaLawlis $11.62 Outstanding Balance $0.00 Notes Date Note Created By: 06/23/2023 Emailed the permit for signature. Kristin Foster Uploaded Files Date File Name 10/23/2023 17271336-20230608 BLD5350 FireDeptApproval.pdf 06/26/2023 15875064-20230622 BLD5350 IssuedPermit.pdf 05/11/2023 15386125-20230510 BLD5350 App.pdf 05/11/2023 15386126-20230510 BLD5350 Datasheet.pdf 05/11/2023 15386127-20230510 BLD5350 Drawing.pdf 05/11/2023 15386128-20230510 BLD5350 FACP-Datasheet.pdf