Loading...
HomeMy WebLinkAbout17216 51st Ave Ne Ste 100_BLD5386_2026 COMMERCIAL PLUMBING APPLICATION ♦ Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360) 403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This includes commercial, tenant improvements, multi-family buildings, roof drains, and overflows, medical gas systems, commercial kitchens, grease traps and interceptors, sumps and cross connection backflow devices. The City of Arlington does not require a permit to stop leaks or clear stoppages,unless the piping is repaired,altered or replaced. SUBMIT THE FOLLOWING ELECTRONICALLY: ❑ Plumbing plans or drawings. (Minimum plan size is 18"X 24"scale,1/4"scale for details.) ❑ Fixture specifications and equipment(cut sheets)with locations. ❑ Location and type of all backflow assemblies for each fixture. IN ADDITION TO ABOVE,SUBMIT THE FOLLOWING,IF APPLICABLE TO YOUR PROJECT: ❑ Calculations for Grease Interceptor. ❑ Pipe size and location of sanitary and potable water systems. ❑ Riser diagram of waste,vent,and rain water systems,including sizes. ❑ Medical gas piping riser diagram,type of gas,storage room and size of piping. Type of Permit: © New Installation ❑ Addition/Alteration/Repair ❑ Industrial Property Address: 17216 51th Ave NE Arlington WA, 98223 Project Valuation: 95 150.00 Lot#: Parcel ID No.: 51052100400100 Preferred Contact: O Owner 9 Contractor TENANT IMPROVEMENT TO BUILDING AND ADDING RESTROOMS, Project Description: jANOwner Name: Smartcap AAIP QOZB LLB Office No.: 4254223484 Email Address: markm@pivotal-gc.com Cell No.: 2062517403 Mailing Address: 8201 164th Ave NE City: Redmond State: Zip: WA 98052 Contractor Name: Bond Plumbing LLC Office No.: 4256728281 g Email Address: Cune. rtis@ bondp lumbin t Cell No.: 2067797441 19023 36th Ave W Lynnwood WA 98036 Mailing Address: City: y State: Zip: L&I Contractor License Number: BONDPPL794MO Expiration Date: 7/29/2023 REV1.2020 Page 1 of 3 PLUMBING PERMIT FEES (per fixture Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two (2) inspections with permit. Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee $ 25.00 $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste x $ 25.00 = Clothes Washer x $ 15.00 = Dishwasher 1 x $ 15.00 = 15.00 Drinking Fountain 1 x $ 15.00 = 15.00 Floor Drains 6 x $ 15.00 = 90.00 Grease Interceptor x $ 75.00 = Grease Trap x $ 25.00 = Hose Bibb x $ 15.00 = Icemaker Refri erator 2 x $ 15.00 130.00 Irrigation-per meter x $ 25.00 = Kitchen Sink&Disposal 1 x $ 15.00 = 15.00 Laundry Tray. 2 x $ 15.00 = 30.00 Lavatory 9 x 1 $ 15.00 = 135.00 Med Gas Pi in <- 5 inlets outlets x $ 60.00 = Med Gas Piping> 5 inlets/outlets (plus:5 5 x $ 5.00 = inlets outlets Miscellaneous-regulated by plumbing x $ 15.00 = code,not otherwise specified Pretreatment Interceptor x $ 15.00 = Re-inspection Fee all x $ 75.00 = Roof Drains x $ 15.00 = Shower onl x $ 15.00 = Sink bar,service,etc. 1 x $ 15.00 = 15.00 Toilets 10 x $ 15.00 = 150.00 Urinal 5 x $ 15.00 = 75.00 Vacuum Breakers x $ 25.00 = Water Heater 2 x $ 25.00 = 50.00 Water Heater-Tankless x $ 25.00 = Permit Fee 645.00 Table 4-6; Plan Review Fee Processing/Technology Fee $25.00 Total 670.00 REV1.2020 Page 2 of 3 PROPOSED BUILDING USE ❑✓ New ❑ Restaurant ❑ Automotive Based ❑ Addition/Alteration ❑✓ Office ❑ Machine Shop ❑✓ Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease ❑ yes ❑✓ No ❑ Don't Know interceptor? Does the plumbing system currently have an oil/water ❑ yes ❑✓ No ❑ Don't Know separator? Is water used in the business process (washing,rinsing, ❑ yes ❑✓ No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑ Yes ❑✓ No ❑ Don't Know I hereby certify that I am the ❑Owner, ❑Applicant, ®✓ Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained when complete. Curtis Bond 06/06/2023 Signature Print Name Date SAVE PRINT REV1.2020 Page 3 of 3 44 Aqualyn° �' Countertop Sink ® BARRIER FREE VITREOUS CHINA Aqualyn°Countertop Sink • Made from vitreous china • Self-rimming with cutout template supplied • • • • Front overflow • Faucet ledge ❑ 0475.020 Faucet holes on 8" (203mm) centers (illustrated) ❑ 0475.920 Faucet holes on 8" (203mm) centers • Less overflow ❑ 0476.028 Faucet holes on 4" (102mm) centers ❑ 0476.037 Faucet holes on 4" (102mm) centers • Extra right-hand hole ❑ 0475.035 Faucet holes on 4" (102mm) centers • Extra left-hand hole SEE REVERSE FOR ADDITIONAL ROUGHING-IN ❑ 0476.928 Faucet holes on 4" (102mm) centers DIMENSIONS • Less overflow ❑ 0475.047 Center hole only 610mm f (24") FINISHED 20mm OPTIONAL (2') Nominal Dimensions: WALL OR BACK(8) mm 518 x 441mm CD 3/16") 1 (20-3/8" x 17-3/8") (7811 118mm) a41mm Bowl sizes: + 203mm DRAWING FOR 406mm (16 ) wide 1 (811) DIMENSIONAL 3'6) MIN, PURPOSES ONLY. 254mm (10") front to back IT IS NOT AN EXACT 845mm REPRESENTATION. 143mm (5-5/8") deep (33-1/4") 686mm Compliance Certifications - 518mm (27") (20-3/8") MIN. Meets or Exceeds the 52mm Following Specifications: COUNTERTOP(BY OTHERS) SEALING COMPOUND �MAX. 7 •ASME All 12.19.2M for BARRIER FREE 1 CLEARANCE 229mm Vitreous China Fixtures 1 (9") `279mm 178mm MIN. (11) (7") V '324mm 12-3T) To Be Specified: AS RE.PPLI s _211-1 8) ❑ Color: ❑ White ❑ Bone 78mm ♦ ♦ (,,,) ❑ Linen ❑ Faucet*: 1-1/4"O.D. 787mm ❑ Faucet Finish: WASTE 87m 1-114'O.D. ❑ Supplies: TAILPIECE FINISHED ❑ 1-1/4"Trap: FLOOR See faucet section for additional models available NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE TEMPLATE SUPPLIED WITH SINK. ❑ MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED AND ANSI A117.1 ACCESSIBLE AND USABLE SEPARATELY. BUILDINGS AND FACILITIES-CHECK LOCAL CODES. SEALING COMPOUND SUPPLIED BY OTHERS. Install lavatory 864mm(34")from finished floor. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range Lavatory installed 51 mm(2")minimum from front edge of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation.No responsibility is of countertop provides 686mm(27")knee clearance area. assumed for use of superseded or voided pages. J29 ©2020 AS America Inc. spec_0475-0476_Aqualyn CountertopSink Rev.3 1/20 Aqualyn° Countertop Sink ® BARRIER FREE VITREOUS CHINA 0476.037 Faucet holes on 4" (102mm)centers 0476.028 Faucet holes on 4" (102mm) centers • Extra right-hand hole 6 810mm FINISHED 51mm (24) FINISHED 116mm 51mm (24) WALLOP 102mm OPTIONAL IT) WALL OR 102mm Ib112'I OPTIONAL (2") SPLASH BACK (4•) SPLASH BACK(4�) mm ]1mm 12-13/18')]9mm 181mm 181 mm 1 441mm 203mm DRAWING FOR 441 m 203mm DRAWING FOR M9"N DIMENSIONAL (1]-3/e") (5) DIMENSIONAL PURPOSES ONLY. PURPOSES ONLY. C/L 1T IS NOT AN EXACT CIL IT NOT AN EXACT 845mm REPRESENTATION. 865mm REPRESENTATION. (331/4") (331/4) BB6m 68fimm 518mm MIN) 518mm MIN) (20-3/8") za 3re^) 152mm 152mm COUNTERTOP SEALING COMPOUND MAX COUNTERTOP SEALING COMPOUND—, M.X_ IBY OTHERS) (BY OTHERS) ` BARRIER FREE B4 R R FREE CLEARANCE CLEARANCE 229mm p. I7 R]9mm 9') 27emm 1]8mm 2MN)m (11,) 117*) MIN. (11•) (]') '324 m 1]') "326mm J (12-3/4') 12-3/Z) SUPPLIES 20 SUPPLIES 203mm AS RED' (81)•) AS REO'D. I^ (e') y 1'Bm)m y 1]Bmm T (]') 1-1/4.O.D. ]8]m 1-1 WAST ]B]m WASTE (31,) WASTE (31') 1-1I6.O.D. �® TAILPIECE FINISHED 1-1/4'ECE FINISHED ® FLOOR TAILPIECE FLOOR 0475.035 Faucet holes on 4" (102mm)centers • Extra left-hand hole 610mm F mm 24") INISHED 114 WALL Ia-12') 1(4") OPTIONAL (2") SPLASHH BACK (4") ]9mm 71 mm } (2-13/16') 81mm (]-1/8") . I 641mm 203"1!^' DRAWING FOR (1]-3/e') (8"}"'" DIMENSIONAL MIN" PURPOSES ONLY C/L IT IS NOT AN EXACT B45mm REPRESENTATION. (33-1/4') 68fimm 518mm (27) (20-3/8") MIN. 152mm COUNTERTOP SEALING COMPOUND Is) (BV OTHERS) MAX. BARRIER FREE _1 CLEARANCE:' 229mm N 2)97771 1]8m(]m MIN. m11 ) 324 2-3/4") SUPPLIESA.FEC. I�203 1 IT' //1 T 1-1/d'O.D.J WASTED / ]8]m J/ 1-1/4'O.. FINISHED TAILPIECE FLOOR MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES NOTES: AND ANSI A117.1 ACCESSIBLE AND USABLE *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"PI'TRAP ARE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. SUGGESTED. FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE Install lavatory 864mm(34")from finished floor. TEMPLATE SUPPLIED WITH SINK. Lavatory installed 51 mm(2")minimum from front edge FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED of countertop provides 686mm(27")knee clearance area. SEPARATELY. SEALING COMPOUND SUPPLIED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. J30 ©2020 AS America Inc. PARTMALIX] ` spec_0475-0476_Aqualyn CountertopSink Rev.3 1/20 4;;Iof?pems MaderaTm FloWise° 15" Height Sea�7 Elongated Flushometer Toilet VITREOUS CHINA with EVERCLEAN° Madera— FloWise° 15" Height Elongated with EverClean® • • Floor mount flushometer valve toilet • Vitreous china • High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf) • Meets definition of HET (High Efficiency Toilet) when used with a high efficiency flush valve I, (1.1 gpf, 1.28 gpf or 1.6/ 1.1 gpf dual flush) • Permanent EverClean°surface inhibits the growth of stain and odor-causing bacteria, mold, and mildew on the surface • Fully glazed 2-1/8" trapway _ • Elongated bowl • 10" or 12" roughing-in • 15" rim height • Condensation channel prevents water from dripping on the floor • Powerful direct-fed siphon jet action • 10" x 12" water surface area • 1-1/2" inlet spud • 2 bolt caps • Tested to support static weight load of 1,000 lbs. (454kg) SEE REVERSE FOR ROUGHING-IN DIMENSIONS ❑ 3451.001 Elongated bowl only, top spud To Be Specified: ❑ 3452.001 Elongated bowl only, top spud with ❑ Color: ❑ White slotted rim for bedpan holding ❑ Seat: ❑ 3453.001 Elongated bowl only, back spud ❑American Standard#5901.100 Heavy duty ❑ 3455.001 Elongated bowl only, back spud with open front less cover ❑American Standard#5901.100SS Heavy duty slotted rim for bedpan holding open front less cover with EverClean® ❑ Flushometer Valve: System MaP* Score: ❑1.6 gpf: • 1,000 grams of miso @ 1.1 gpf, 1.28 gpf or 1.6 gpf ❑ Sensor-Operated: American Standard Selectronic® when used with an American Standard flush valve DC Power#6065.1 American (Top Spud) *Maximum Performance (MaP)nduc testing performed ul IAPMO ❑ Sensor-Operated: American Standard Selectronic R&T Lab.MaP Report conducted by Veritec Consulting, Inc. and Koeller and Company. AC Power#6067.261.002 (Back Spud) ❑ Manual:American Standard#6047.161.002 Component Parts: (Top Spud) ❑ 047007-0070A Inlet Spud (furnished with bowl) ❑1.28 gpf: ❑ 034783-0200A Bolt caps with retainers ❑ Sensor-Operated: American Standard Selectronic (furnished with bowl) DC Power#6065.121.002 (Top Spud) ❑ Sensor-Operated: American Standard Selectronic Nominal Dimensions: AC Power#6067.221.002(Back Spud) 718 x 356 x 381mm ❑ Manual:American Standard#6047.121.002 (28-1/4" x 14" x 15") (Top Spud) ❑1.6/1.1 gpf Dual Flush: Fixture only, less seat and flush valve ❑ Sensor-Operated: American Standard Selectronic Recommended working pressure—between DC Power#6065.761.002 (Top Spud) 25 psi at valve when flushing and 80 psi static CE0 �♦� Compliance Certifications - 03'"Ses4 0 Meets or Exceeds the Following Specifications: PPO ~ •ASME A112.19.2/CSA B45.1 for Vitreous ENVIROMENTAL when used with EVERCLEAN WATER China Fixtures PRODUCT 1.1or1.28gpf EFFICIENT DECLARATION toilet flush valves 5 ©2021 AS America Inc. spec_3451.001 Madera FW 15Height-EL-Flushometer Rev 3 5/21 MaderaTM FloWise° 15" Height S� Elongated Flushometer Toilet VITREOUS CHINA with EVERCLEANO 3451.001 /3452.001 1"N.P.T.OR 1" FINISHED WALL C.W.T.SUPPLY TO FLUSH VALV 718 121mm mm � (4-3/4") 673mm (28-1/4") (26-1/2") 102mm I, 470mm 56mm 1(4") (18-1/2") (14) 25mm C/L OF SEAT POST HOLES 1 1/2 (1") �140mm(5-1/2")CENTERS SPUD 381 mm (15') 1 FINISHED FLOOR MN 362mm 5-7/8" i (14-1/4")� 254mmI I ILI �7"� �13mm (10") (1/2) C/L OF OUTLET 254mm�� 00") 3453.001 /3455.001 FINISHED WALL 718mm (28 1/4)7 356mm 76mm 470mm (3") �~ (18-1/2") (14) C/L OF SEAT POST HOLES f140mm(5-1/2")CENTERS - -- - 400mm (15-3/4") 381 mm (15") FINISHED FLOOR 150mm 14-mm 254mm 13mm (14-1/4") (10") (1/2) 254mm--­� �C/L OF OUTLET (10") NOTES: PRODUCT 3451 AND 3453 SHOWN,3452 AND 3455 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE,THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 254MM(10") AND A MAXIMUM DIMENSION OF 305MM(12")FROM FINISHED WALL TO C/L OF OUTLET. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.FLUSHOMETER VALVE REQUIREMENTS FOR 12"(305MM)ROUGH-IN:SWEAT EXTENSION NIPPLE IS REQUIRED. REFER TO VALVE MANUFACTURER AND LOCAL CODES. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. 6 ©2021 AS America Inc. PART OF L I X I L spec_3451.001 Madera FW 15Height-EL-Flushometer Rev 3 521 4;;Iof?pems Madera'" FloWise° 16-1/2" Height S� Elongated Flushometer Toilet VITREOUS CHINA LESS EVERCLEAN° ® BARRIER FREE Madera— FloWise®16-1/2" Height Elongated LESS EverClean° • • Floor mount flushometer valve toilet • Vitreous china • High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf) • Meets definition of HET (High Efficiency Toilet) I, when used with a high efficiency flush valve (1.1, 1.28 gpf or 1.6/ 1.1 gpf dual flush) • Fully glazed 2-1/8" trapway • Elongated bowl • 10" or 12" roughing-in • 16-1/2" rim height for accessible application • Condensation channel • Powerful direct-fed siphon jet action • 10" x 12" water surface area • 1-1/2" inlet spud • 2 bolt caps included • Tested to support static weight load of 2,500 lbs. (1,134 kg) ❑ 3043.001 Elongated bowl only, top spud SEE REVERSE FOR ROUGHING-IN DIMENSIONS ❑ 3248.001 Elongated bowl only, top spud with System Map*Score: slotted rim for bedpan holding • 1,000 grams of miso @ 1.1 gpf, 1.28 gpf or 1.6 gpf ❑ 3249.001 Elongated bowl only, back spud when used with an American Standard flush valve *Maximum Performance(MaP)testing performed by IAPMO Component Parts: R&T Lab.MaP Report conducted by Veritec Consulting, Inc. ❑ 047007-0070A Inlet Spud (furnished with bowl) and Koeller and Company. ❑ 034783-0200A Bolt caps with retainers (furnished with bowl) OPERATING PRESSURE: 25 psi (flowing) - 80 psi (static) Nominal Dimensions: 718 x 356 x 419mm FLOW REQUIREMENT: (28-1/4" x 14" x 16-1/2") 25 gpm (94.6 L/min.) Fixture only, less seat and flush valve Compliance Certifications - To Be Specified: Meets or Exceeds the Following Specifications: ❑ Color: ❑ White •ASME A112.19.2/CSA B45.1 for Vitreous ❑ Seat: China Fixtures ❑American Standard#5901.100 Heavy duty open front less cover ❑American Standard#5901.100SS Extra heavy duty open front less cover with EverClean° ❑ Flushometer Valve: ,a C EC• �♦� O ENVIROMENTAL when'I'd with EVERCLEAN WATER PRODUCT 1.1or1.28gpf EFFICIENT r� MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES DECLARATION toilet flush valves 101 AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE v BUILDING FACILITIES-CHECK LOCAL CODES. M11 ©2021 AS America Inc. spec_3043-48-49.001 Madera FW 16.51deight-EL-Flushometer Rev 3 3/21 Madera' FloWise® 16-1/2" Height S� Elongated Flushometer Toilet VITREOUS CHINA LESS EVERCLEAN® ® BARRIER FREE 3043.001/3248.001 1"N.P.T.OR 1"C.W.T.SUPPLY TO FLUSH VALVE FINISHED WALL 21mm 718mm W (4-3/4')I 711mm 102mm 470mm 356m (4") (18-1/2") (14) M. C/L OF SEAT POST HOLES 1.1/2 (1") L' L 140mm(5-1/2')CENTERS SPUD _ I 419mm - (18-1/2") I I I �362mm FINISHED I (14-1/4") FLOOR 150mm L254.MM-1 13mm (5-7/8") (10") 0/2") 254mm�l (10') C/L OF OUTLET 3249.001 FINISHED WALL 718mm (28-114") 76mm 470mm 356mm IT.) ~(18-1/2') (14") C/L OF SEAT POST HOLES 140mm(5-1/2')CENTERS - --- - i 438mm (17-1/4") 419mm (16-1/2") I I 362mm (14-1/4) FINISHED 150mm FLOOR ~254mm (5-7/8") (10) (1/2- 13mm 254mm� (10') C/L OF OUTLET NOTES: PRODUCT 3043 SHOWN,3248 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE,THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 254MM(10") AND A MAXIMUM DIMENSION OF 305MM(12")FROM FINISHED WALL TO C/L OF OUTLET. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.FLUSHOMETER VALVE REQUIREMENTS FOR 12"(305MM)ROUGH-IN:SWEAT EXTENSION NIPPLE IS REQUIRED. REFER TO VALVE MANUFACTURER AND LOCAL CODES. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard All2.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. M12 0 2021 AS America Inc. PART OF L I X I L spec_3043-48-49.001 Madera FW 16.5Height-EL-Flushometer Rev 3 3/21 4;Pof?k� Washbrook° FloWise° s� Universal Urinal VITREOUS CHINA ® BARRIER FREE Washbrook® FloWise® Universal Urinal • Vitreous china • Ultra High Efficiency, Low Consumption. Operates in the range of 0.125gpf to 1.Ogpf(0.5 Lpf to 3.8 Lpf) • Flushing rim • Elongated 14" rim from finished wall • Washout flush action • Extended sides for privacy • 3/4" inlet spud • Outlet connection threaded 2" inside (NPTF) • 2 wall hangers • Fixture only • Strainer included • Meets ASME flush requirements at 0.125 to 1.0 gpf ❑ 6590.001 Universal Top spud ❑ 6515.001 Universal Back spud f Nominal Dimensions: 360 x 480 x 664mm (14-1/8" x 18-7/8" x 26-1/8") SEE REVERSE FOR ROUGHING-IN DIMENSIONS Recommended working pressure—between To Be Specified: 20 psi at valve when flushing and 80 psi static ❑ Color: ❑ White ❑ Flush Valve: Compliance Certifications - 1.0 gpf Flush Valve: Sensor-Operate®: ❑American Standard Selectronic #6063.101.002 Meets or Exceeds the Following Specifications: DC Power(Top Spud) • ASME A112.19.2-2008/CSA B45.1-08 for Vitreous ❑American Standard Selectronic®#6062.101.002 China Fixtures AC Power(Back Spud) 1.0 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.101.002 0.5 gpf Flush Valve: Sensor-Operated: ❑American Standard Selectronic°#6063.051.002 DC Power(Top Spud) ❑American Standard Selectronic°#6062.051.002 AC Power(Back Spud) 0.5 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.051.002 0.125 gpf Flush Valve: Sensor-Operated: ❑American Standard Selectronic®#6063.013.002 DC Power(Top Spud) ❑American Standard Selectronic®#6062.013.002 AC Power(Back Spud) 0.125 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.013.002 �5e0� A��� MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES ��' —C'` —" AD4 AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND v FACILITIES-CHECK LOCAL CODES. When used with When used with ADA •When installed so top of rim is 432mm(17")MAXIMUM from finished floor. 0.125 gpf 0.125 or 0.5 gpf COMPLIANT urinal flush vale urinal flush vale M155 ©2018 AS America Inc. spec_6590.001-6515.001 WashbrookUrinal Rev 11/18 Washbrook° FloWiseO S� Universal Urinal VITREOUS CHINA ® BARRIER FREE 6590.001 TOP SPUD 6515.001 BACK SPUD 121 mm�.� (4-3/4") 3/4"S.P.S. FINISHED yf OR 3/4"C.W.T. WALL T SUPPLYTO FINISHED FLUSH VALVE 292mm 3/4" j 64mm I WALL (11-1/2") SPUD K2 HANGERS (2-1/2'. 51mm K2 HANGERS 51mm (2��) I � (2") (8mm x 25mm 1 Smm x 25mm �� �+�� SLOT x 1 ) �� 42 j�*� (5/16"x 1") — 7 SLOT 3/4" t 343mm t 343mm SPUD 445mm (13-1/2") (13-1/2") (17-1/2") 480m 35m 171/2') 9-1/4') (180M.. (9-1/4") ( 480mm 464mm (18 7/8) 464mm 664mm (18-1/4") 664mm (18-1/4") (26-1/8) 360mm (26 1/8) 360mm REF. (14-1/8") REF. (14-1/8") 13mm 13mm (1/2") (1/2") 83mm 83mm —T, ■432mm® 0432mm 161 C/L OF (17")MAX 102mm C/L OF (17")MAX 2"N.P.T. 102mm OUTLET 610mm(24") 2"N.P.T. (4") OUTLET 610mm(24")FEMALE OUTLET (4") OPTIONAL FEMALE OUTLET OPTIONAL CONNECTION FINISHED FLOOR CONNECTION FINISHED FLOOR 13mm 13mm (1/2") ASKET (1/2") GASKET i�r 1 1 rn r I I 1 r- `u` i�102mm� 13mm �\2" 02mm, 13mm Ili N.P.T. 2"N.P.T. FINISHED WALL INSIDETHREADS FINISHED WALL INSIDETHREADS DETAIL OF OUTLET CONNECTION DETAIL OF OUTLET CONNECTION ■ , MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. •When installed so top of rim is 432mm(17")MAXIMUM from finished floor. NOTES: FLUSH VALVE NOT INCLUDED AND MUST BE ORDERED SEPARATELY. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. M156 ©2018 AS America Inc. PART OF L I X I L spec_6590.001-6515.001 WashbrookUrinal Rev 11/18 /jtp/►�,ajL LUCERNE TM �'taivaita/ WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE LUCERNETM WALL-HUNG LAVATORY • Wall-hung sink • Vitreous china • Front overflow ' • D-shaped bowl • Self-draining deck area with contoured ' - back and side splash shields • Faucet ledge • Compliant with Texas accessibility standard (TAS) for children age group 13 and up Faucet holes on 203mm (8") centers (Illus.): ❑ 0356.028 For exposed bracket support Shown with 4801.862 Amarilis Heritage faucet with Triune Cross handles (not included) ❑ 0356.015 For wall hanger(included) or concealed arms support ❑ 0356.915 For wall hanger (included) or 0356.028 concealed arms support • Less overflow Faucet holes on 102mm (4") centers: ❑ 0355.027 For exposed bracket support ❑ 0355.012 For wall hanger(included) or concealed arms support ❑ 0355.912 For wall hanger (included) or concealed arms support • Less overflow Single center faucet hole (Illus.): ❑ 0356.041 For exposed bracket support Shown with 1340.000 metering faucet (not included) ❑ 0356.421 For wall hanger(included) or concealed arms support ❑ 0356.921 For wall hanger (included) or concealed arms support • Less overflow 0356.041 ❑ 0356.439 For wall hanger (included) or concealed arms support SEE FOLLOWING PAGES FOR ROUGHING-IN DIMENSIONS •Single faucet hole on right ❑ 0356.066 For exposed bracket support •Single faucet hole on right To Be Specified: ❑ Color: ❑White Nominal Dimensions: ❑ Faucet*: 521 x 464mm ❑ Faucet Finish: (20-1/2" x 18-1/4") ❑ Supplies: Bowl sizes: ❑ 1-1/4"Trap: 381mm (15") wide ❑ Nipple: 254mm (10") front to back ❑ Bracket Support(by others): 165mm (6-1/2") deep ❑ Concealed Arms Support(by others): Compliance Certifications - Meets or Exceeds the Following Specifications: • AS ME Al l2.19.2/CSA B45.1 for Vitreous See faucet section for additional models available China Fixtures MEETS THE AMERICANS WITH DISABILITIES ACT GUIDE- ® LINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. Top of front rim mounted 864mm(34")from finished floor. M37 C 2016 AS America Inc. spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 LUCERNE TM S� WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE 0356.028 8" CTRS FOR EXPOSED BRACKET SUPPORT 0355.027 4"CTRS FOR EXPOSED BRACKET SUPPORT 0356.015 8" CTRS FOR WALL HANGER 0355.012 4"CTRS FOR WALL HANGER OR OR CONCEALED ARMS CONCEALED ARMS 0356.915 LESS OVERFLOW 0355.912 LESS OVERFLOW t 86mm 86mm 102mm (3-3/8') 102mm (3-3/8") FINISHED (4") 0 FINISHED(4") FINISHED WALL 203mm WALL 203mm WALL 152mm 152mm 464mm 102mm 464mm 152 mm 203mm (18-1/4") (q) (18-114") 152mm I I I I emm 8mm (6)25mm (5/16") (6)25mm (1')DIA. (1")DIA. ACCESS ACCESS 13mm HOLES 13mm HOLES FOR (1/2") (1/2') CONC.ARMS 521mm FOR 521mm (20-1/2") CONC. (20-1/2") ARMS 425mm 425mm (16-3/4") (16-3/4") 267mm 267mm (10-1/2') 54mm(2-1/8")DIA. (10-1/2')� 114mm HOLES FOR 114mm (4-1/2") CONCEALED ARMS (4-1/2') 54mm(2-1/8")DIA. 102mm 44mm 25mm 102 m 4-3/4 HOLES FOR (1 3/4") (1-3/4') CONCEALED ARMS (4") (1') i^1 /l�I (4") 25mm �1 /� +- -+ +IV 1" -+- +I 79mm 1 �I 79mm /mil 7 (3-1/8") ______� ♦ *298mm (3-18") ♦ --+--J 206mm (11 i (8-1/8") 38mm 0 38mm 10mm(3/8') 10mm (18m. DIA.ANCHOR *286mm (1'1/2') E 3/8')) (11-1/4') DIA. HOLEES c? SCREW HOLES *352mm SCREW HOLES E S-9 HANGER 2le)m (13-7/8') S-9 HANGER 20 e Im *.- N 27mm X 14mm ♦ ♦ 27mm x 14mm ♦ ♦ + m (1-1/16"x 5/16")SLOTS /j /// SLOTS SUPPLIES) / SUPPLIESf� 1 Vy AS REQUIRED J// 787mm(31') AS REQUIRED E E 1-1/4"O.D.WASTE 864mm(34") 1-1/4'O.D.WASTE 1-1/4"O.D.WASTE 1-1/4"O.D.WASTE OUTLET FOR OUTLET FOR OUTLET FOR OUTLET FOR FINISHED FINISHED DRAIN PLUG POP-UP DRAIN f FLOOR 1® DRAIN PLUG POP-UP DRAIN f FLOOR 1 T7 18-1/4" FINISHED 18-1/4" FINISHED (464mm) WALL (464mm) r WALL 8"MIN. 8"MIN. 34" - (203mm) 34" (203mm) (864mm) (864mm) 27"MIN. 27"MIN. (686mm) (686mm) 6"MAX. _ 6"MAX. (152mm) (152mm) BARRIER FREE 9"MIN. ,BARRIER FREE 9„MIN. CLEARANCE (229mm) CLEARANCE (229mm) 11" 11" (279mm) (279mm)� NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Al12.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. FLAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM(34")ABOVE FINISHED FLOOR. M38 ©2016 AS America Inc. PART OF l I X I` spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 LUCERNE TM 54t7 ; / WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE 0356.041 SINGLE CENTER HOLE FOR EXPOSED 0356.439 SINGLE CENTER HOLE ON RIGHT FOR WALL BRACKET SUPPORT HANGER OR CONCEALED ARMS 0356.421 SINGLE CENTER HOLE FOR WALL 0356.066 SINGLE CENTER HOLE ON RIGHT FOR HANGER OR CONCEALED ARMS EXPOSED BRACKET SUPPORT 0356.921 LESS OVERFLOW 44­(1-3/4")DIA. 251m(1-3/8')DIA. 349mm 35mm(1-3/8')DIA. STD.OUTLET PUNCHING (13-3/4•) PUNCHING 102mm 86mm (4.) (3-3/8") 114mm 86mm (4-1/2') (3-3/8") FINISHED 203mm WALL (8�) FINISHED 203mm 15(6") WALL (6) 13mm x 51mm BRACKET (1/2"x T)SLOTS 464mm 44mm(1-3/4")DIA. 464mm STD.OUTLET (18-1/4') 152mm (6„) 102mm 25mm(1')DIA. i (4)i HOLES Bmm 57mm Bmm (6)25mm(1")DIA. ACCESS HOLES } 1 FOR CONC.ARMS 13mm (1/2•) 425mm (16-3/4') 13mm 521 mm (112") (20-1/2") 521 mm (20-1/2') 425mm 425mm (16-3/4') (16-3/4') 7267mm 267mm 10-1/2') (10-1/2')~ 114mm 14mm (4-1/2") 4-1/2') 54mm(2-1/8")DIA. 54mm(2-1/8")DIA. HOLES FOR 102mm 44mm 25mm I HOLES FOR 102mm 44mm CONCEALED ARMS (4") (1-3/4") CONCEALED ARMS 25mm - - + + + + 0") I+ +`Fig + +I 79mm �- II i�l } (3.1/8") --1-_1 / / (391/8") 206mm 206mm 382 10mm(3/8") I 38mm J 10mm(3/8") (1-1/2") DIA.ANCHOR 787mm(31') (1-1/2") DIA.ANCHOR 787mm(31') SCREW HOLES 864mm(34') SCREW HOLES ®864mm(34') S-9 HANGER S-9 HANGER 27mm X 14mm FINISHED ® FINISHED (1-1/16'x 5/16")SLOTS FLOOR 27mm X 14mm f FLOOR (1-1/16"x 5/16')SLOTS T7 18-1/4" FINISHED 18-1/4" FINISHED (464mm) WALL (464mm) WALL 8" MIN. 8"MIN. 34" (203 m m) 34" (203 m m) (864mm) (864mm) 27"MIN. 27"MIN. (686mm) (686mm) 6" MAX. 6"MAX. (152mm) (152mm) BARRIER FREE 9, MIN. BARRIER FREE'*.,'.- MIN. CLEARANCE (229mm) CLEARANCE (229mm) 11" 11" (279mm) (279mm) NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard At12.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. ❑LAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT (� SET AT 864MM(34")ABOVE FINISHED FLOOR. M39 ©2016 AS America Inc. PART OF L I X I L spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 46. W.160th St. Dearborn Oleveland.Ohio44135 CAST GRID WHEELCHAIR Ph:(800)321-9532 Brass Fax:(dea)ornbra35 PATENT OUTLET PLUG vnHv.d e a rbo rn b ras s.com SUBMITTAL SPECIFICATION Engineering Specification: Dearborn Brass Semi-Cast Wheelchair Grid Patent Overflow Job Reference Plug with 1-%"—17 gauge tailpiece. DESCRIPTION • Chrome Finished • Includes: Cast Grid, P.O. Plug with nuts and washers, 90' Elbow and 17 gauge tailpiece • Designed for installation in most commercial _ applications r, I I�2-1/5"� DIP_ 2-314' 5-114' 7- 112" —i 1-114" 1— Product Description Carton Carton Weight(Ibs) No. Quantity 760W-1 Semi-Cast Grid Wheelchair Patent Overflow Plug 10 14 with 1-%"—17 gauge Tailpiece Data is subject to manufacturing tolerances. Visit www.dearbornbrass.com for updates 03/2009 L=wL I�, 0 o� .R Ll 1111 1 THIS PRODUCT,AS CONSTRUCTED IS SUBJECT TO INTERPRETATION OF A.D.A. REQUIREMENTS. THE UNOBSTRUCTED KNEE SPACE REQUIRED TO SATISFY A.D.A. f t STANDARDS MAY NOT BE DESIRABLE. j ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP PRODUCT SPECIFICATIONS Elkay Enhanced ezH2O®Bottle Filling Station, &Versatile Bi-Level ADA Cooler, Filtered Refrigerated Light Gray. Chilling Capacity of 8.0 GPH (gallons per hour)of 501 F drinking water, based on 801 F inlet water and 901 F ambient, per ASHRAE 18 testing. Features shall include Antimicrobial,Automatic Filter Status Reset, Energy Savings, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain, Visual Filter Monitor. Furnished with Flexi-Guard®Safety Bubbler. Electronic \, Bottle Filler Sensor with Electronic Front and Side Bubbler Pushbar activation. Product shall be Wall Mount(On Wall),for Indoor - applications, serving 2 station(s). Unit shall be certified to UL 399 and CAN/CSA C22.2 No. 120. Unit shall be lead-free design which is certified to NSF/ANSI 61 &372(lead free)and meets Federal and State low-lead requirements. Special Features: Antimicrobial,Automatic Filter Status Reset, Energy Savings, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain,Visual Filter Monitor Finish: Light Gray Granite AMERICAN PRIDE. A LIFETIME TRADITION. Like your family,the Elkay family has values and traditions that Power: 115V/60Hz endure.For almost a century,Elkay has been a family-owned and USA Bubbler Style: Flexi-Guard®Safety Bubbler operated company,providing thousands of jobs that support our ®. Activation by: Electronic Bottle Filler Sensor with families and communities. Electronic Front and Side Bubbler Included with Product: Bottle Filler, Pushbar Water Cooler, Mounting Type: Wall Mount(On Wall) Filter Chilling Capacity*: 8.0 GPH Ships in one box. Full Load Amps 5 PRODUCT COMPLIANCE Rated Watts: 370 ADA& ICC A117.1 Dimensions(L x W x H): 36-3/4"x 19"x 39-1/2" Approx.Shipping Weight: 104 lbs. ASME Al 12.19.3/CSA B45.4 Installation Location: Indoor Buy American Act No. of Stations Served: 2 CAN/CSA C22.2 No. 120 *Based on 80' F inlet water&90' F ambient air temp for 50' F chilled GreenSpec° drinking water. NSF/ANSI 42, 53, 61, &372 (lead free) Special Note: One-Box Packaging. UL 399 • Visual Filter Monitor: LED Filter Status Indicator for when filter GreenSpec s change is necessary. 6 r • Ab- • Filter is certified to NSF 42 and 53 for lead, particulate, U$ `� � L I ST E o chlorine,taste and odor reduction. 3,000 gal. capacity. c us www Gre SPe< ' • Energy-Savings Feature-allowing for the refrigeration to be Complies with ADA&ICC Al 17.1 accessibility requirements when installed according to the requirements outlined in these standards.Installation may powered off when not In use. require additional components and/or construction features to be fully • Green Ticker: Informs user of number of 20 oz. plastic water compliant.Consult the local Authority Having Jurisdiction if necessary. bottles saved from waste. Installation Instructions(PDF) • Laminar flow provides clean fill with minimal splash. • Silver Ion Antimicrobial protection on key plastic 5 Year Limited Warranty on the refrigeration system of the unit. components to inhibit the growth of mold and mildew. Electrical components and water system are warranted for 12 months • Real Drain System eliminates standing water. from date of installation. Warranty pertains to drinking water applications only. Non-drinking water applications are not PART: QTY: covered under warranty. PROJECT: Warranty(PDF) CONTACT: DATE: NOTES: APPROVAL: In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Pagel LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP COOLING SYSTEM • Compressor: Hermetically-sealed, reciprocating type, OPTIONAL ACCESSORIES single phase. Sealed-in lifetime lubrication. 51300C- Elkay WaterSentry Plus Replacement Filter(Bottle Fillers) • Condenser: Fan cooled, copper tube with aluminum WSF6000R-2PK-WaterSentry Fresh 6000 CTO Replacement Filter fins. Fan motor is permanently lubricated. (2pack) • Cooling Unit: Combination tube-tank type. Continuous MLP200-Accessory- In Wall Carrier(Bi-Level)for bi-level EZ, LZ, copper tubing with is fully insulated with EPS foam that EMABF, LMABF,VRC, LVRC models meets UL requirements for self-extinguishing material. LKAPREZL- Elkay Cane Apron for EZ Gray • Refrigerant Control: Refrigerant R-134a is controlled by accurately calibrated capillary tube. • Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 2 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP IMPORTANT! OPERATION OF QUICK CONNECT FITTINGS INSTALLER PLEASE NOTE : This water cooler has been designed and built to provide water to the user which Simply push in Tube is secured I Push in collet to has not been altered by materials in the cooler waterways.The grounding of electrical tube to attach in position release tube equipment such as telephone,computer,etc_to water lines is a common procedure. A B C The grounding maybe in the building but may also occur away from the bulling.This � « grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below. Pushing tube in before NOTICE pulling it out helps to This water cooler must be connected to the water supply using a dielectric coupling.The F.—I release tube cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. These products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. WaterSentry®Plus Filter System Standard Hli-Low Installation Instructions 1s° (458mm) (467mm) 7° 7" (178mm) (178mm) 7/16"X 3l4" ((11 mm X 19mm 0 ROUND HOLE(6) 0 9/32" r — 3m (7mm ACTIVATION (483mm) 6-318" 6-70mL�S(12) 6-3/8" 6-3/8" SENSOR 901/ (162mm) (162mm) (162mm) (162mm)' HANGER (381 mm) BRACKET 483mm) — 38-1/2" O s'Imm __ �� (979mm) E = -=—i- --2. 2-7/8" --, (51mm) _ 38-3/8" FILTER r e i i m/ 1--^ --- 73mm (975mm — 1 (�2Jm) i -1—_-' E s�mm) bHEIGHT 0 ii -r "i ---- I 36-13/16" 51-/16" i i A (1310mm i i PREFERRED 28-13/16' (936mm) 34-/16" F i i i i i i I LOCATION (731mm) HEIGH (205mRIM ") I3ii T 205mm (872mm) i L--�---- --i -- --i 32-/8" FILTER -- —_� i (835mm) L 2,N/2" ORIFICE C (622mm) T HEIGHT i _ _ _ 21-718" 31-5/16" 2-15116' —_ (556mm) (686mm) (583mm) RIM 17-7116" HEIGHT 27" 1-/8" 19-116" (51mm) F (443mm) (686m ) (4ADA8mm) (494mm) 3-718' 13-15/16" 19" 3 5-314" (98mm) (354mm) (483mm) REQUIREMENT (76mm) 146mm 1 ( 7" 7" (318mm8mm) (178mm) (178mm) LEGEND: REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51 mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply 3)Wire Recessed Box Duplex Outlet. E=Insure proper ven Ration by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7/16"(11 mm)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI). It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 3 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP IMPORTANT! OPERATION OF QUICK CONNECT FITTINGS INSTALLER PLEASE NOTE : Simply push in Tube is secured Push in collet to This water cooler has been designed and built to provide water to the user which P y P has not been altered by materials In the cooler waterways.The grounding of electrical tube to attach in position release tube equipment such as telephone,computer,etc.to water lines is a common procedure. The grounding may be in the building but may also occur away from the building.This x ~ grounding can cause electrical feedback into a water cooler creating an electrolysis A B C which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown Pushing tube in before below. pulling It out helps to NOTICE release tube This water cooler must be connected to the water supply using a dielectric coupling.The cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. These products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. Watersentry Plus Filter System 18" Optional Reverse(Hi-Low) Installation Method (458mm) 18-3/8" 7/16"X 3/4" 7„ 7" (467mm) (11mm X 19mm) (178mm) F(i 78mm) 19 OBROUND HOLE(6) (483mm) 51-518" ACTIVATION (1311mm) 6-3/8" 6-3/8" SENSOR 3-1/2" i (162mm) (162mm) (90mm) 15" 6-3/8" 6-3/8" HANGER (381mm (162mm) (162mm) (07m/m)2) BRACKE HOLES(12) I i �• (38-318" 38-9/16" 2716' 111 E ORIFIC� (979mm) (73rnm) HEIGHT PREFERRED E '-- LOCATION 36-13/16' __ (936mm) 28-13116" r Q i (51mm) 34-5116" RIM (732mm) B --i i 22mm) I 871mm) HEIGHT FILTER r- 32-7/8" - I I- i i _ I (835mm) (205mm) -- 1 11,7 i - --- - - ORIFICE ' II --L i i I I _ HEIGHT FILTER 21-718" i i �• i 31-5/16" (556mm) F I 2" (796mm) I 19" (5 3/4'� F 2-1 /16' RIM C (483mm) T (146/mm) (583mm) HEIGHT 3-7/8" 27" (178mm) (178mm) 24-1/2" (686mm) 1-7/8" 443m16" (98mm) 119`-7/116"(622mm) ADA (48mm) REQUIREMENT 3" 12-1/2" (76mm) 13-15/16" (318mm) (354mm) FINISHED FLOOR LEGEND: REDUCE HEIGHT BY3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51 mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. E=Insure proper ventilation by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7116"(11 mm)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI).It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 4 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP—spec.pdf PROFESSIONAL CALIBER When it comes to eliminating system pressure, FLEX 2 PRO PH is your safe bet. o Worrying about eliminating system pressure is a thing of the past! FLEX 2 PRO PH potable water expansion tanks are designed to maintain safe pressure in domestic water systems that utilize a back flow preventer or check valve. Equipped with a stainless steel system connection to prevent corrosion, the � - FLEX 2 PRO PH is in a FLEXCON whole different league. A Swan Group Company Potali4 N',,leL�Tank Stainless steel water connections ..N .,.m �,..N. hu. 0 PHI2.1 p.11n.a NO rGl IN esm to reduce corrosion. Mt.I-- E..r,I o..: — 16 gauge solid steel tank,finished with highest quality urethane paint. Steel clench ring regulates movement and prevents diaphragm from rubbing against tank wall. PROBLEM SOLUTION FIXTURE .ACNFLOW pH VALVE CLOSE. PREVENTED OR Tank CHECK VALVE PH series thermal expansion tanks effectively eliminate built up system pressure. 100%pressure tested and backed with a 1 year limited warranty. o Adding a backflow Installed on the cold preventer, check water inlet, PH series valve or water meter thermal expansion with a check valve tanks provides a reser- creates a closed voir for the water to loop system. When expand. The water water heats up, it safely enters the expands with no place tank and is released to go except through back into the system the relief valve. on demand. ©2017 Flexcon Industries REV:9-17 PH SERIES TYPICAL INSTALLATION Potable Water Cold Hot 4;12> Expansion Tanks =Backkfiow Relief MATERIALS OF CONSTRUCTION Valve ■ Tank: 16 gauge cold rolled steel WH ■ Finish:Appliance quality paint for indoor or outdoor installation SERIES ■ Water chamber: 100% butyl rubber, lined with polypropylene ■ Connection:Stainless steel ■ Testing: High pressure, seam weld, helium, final precharge check ■ Air valve: Brass valve with o-ring seal ■ Warranty: 1 year limited DIMENSIONS & CAPACITIES ModelF2. l Tank A B C Total c us •••w••= ume Height Diameter Connection Weight liters in cm in cm Ibs kilos PH 5 8 11.6 30.00 8.0 20.00 3/4"MNPT 5.00 2.3 PH 12 18 14.5 37.00 11.00 28.00 3/4"MNPT 10.00 4.6 PH 25 32 1 18.9 48.10 1 12.50 31.80 3/4"MNPT 15.40 7.0 Maximum working pressure 150 psig. Maximum working temperature, internal&external 200,F.Tank pre-charge 40 psig. NOTE: Ph Series tanks are certified to NSF Standard 61 Domestic Hot, but are suitable for temperatures up to 200,F. C B QUICK SIZING CHART Water Heater Maximum Water Temperature Size/Volume 1301 F 1400 F 1600 F 1800 F 30 GALLONS PH 5 PH 5 PH 5 PH 5 40 GALLONS PH 5 PH 5 PH 5 PH 5 A 50 GALLONS PH 5 PH 5 PH 5 PH 12 60 GALLONS PH 5 PH 5 PH 5 PH 12 80 GALLONS PH 5 PH 12 PH 12 PH 12 100 GALLONS PH 12 PH 12 PH 12 PH 25 120 GALLONS PH 12 PH 12 PH 12 PH 25 150 GALLONS PH 12 PH 12 PH 25 PH 25 175 GALLONS PH 12 PH 25 PH 25 PH 25 *Consult Factory LPc_ Sizing based on water heater recovery from 40F, water supply pressure of 60 PSIG, and relief valve set at 150 PSIG. Adjust tank precharge to equal incoming water pressure. FLEXC _ ■ 0 A Swan Group Company O www.fIexconind . coin O 8 0 0- 5 2 7-0 0 3 0 O 300 Pond Street, Randolph , MA 02368 Company name: - � 0Created by- Phone: Phone: G IZ V N n FO S ° ` Fax: - Date: - Position Count Description Unit price -1 UP 15-18 B5/TLC On request Product photo could vary from the actual product Product No.: 59896212 The pump is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. The pump is characterized by: * Ceramic shaft and radial bearings. * Carbon axial bearing. * Stainless steel rotor can and bearing plate. * Corrosion-resistant impeller, Composite, PES. * Bronze pump housing. The motor is a 1-phase motor. No additional motor protection is required. Liquid: Liquid temperature range: 35.6 .. 150.8 °F Density: 62.4 Ib/ft3 Technical: Maximum operating pressure: 145 psi Approvals on nameplate: UL, CSA Materials: Pump housing: Bronze DIN W.-Nr. 2.1176.01 Impeller: Composite, PIES Installation: Maximum ambient temperature: 104 °F Ambient max at 176°F liquid: 176 °F Maximum operating pressure: 145 psi Flange standard: USA Sweat Type of connection: Bronze Sweat Pipe connection: 1/2" Sweat Pressure stage: 10 Port-to-port length: 5 in Electrical data: Printed from Grundfos CAPS[2011.05.069] G IZIJ N ED FOS'M 1/4 Company name: - �� Created by- Phone: Phone: G ■t VNnPOS � �p ` Fax: - Date: - Position Count Description Unit price Number of poles: 2 Max. power input: 85 W Rated power-P2: 0.04 HP Main frequency: 60 Hz Rated voltage: 1 x 115 V Current in speed 3: 0.74 A Capacitor size-run: 10 pF/180 V Insulation class (IEC 85): F Others: Gross weight: 6.5 lb Printed from Grundfos CAPS[2011.05.069] G IZU N ED FOS'M 2/4 Company name: - �� Created by: Phone: G n V N FO S ° ` Fax: - Date: - Description Value H UP 15-18 B5/TLC,60 Hz Product name: UP 15-18 B5/TLC (ft) Density=62.4 lb/ft' Product Number: 59896212 12 EAN number: 5700392936370 10 Technical: 8 Speed Number: 1 Max flow: 14.5 US gpm 6 Head max: 13.8 ft Maximum operating pressure 145 psi 4 Approvals on nameplate: UL,CSA 2 Materials: Pump housing: Bronze 00 1 2 3 4 5 6 7 Q(US gpm) DIN W.-Nr.2.1176.01 P2 Impeller: Composite,PES (HP) 0.03 Installation: 0.02 Maximum ambient temperature: 104°F Ambient max at 1760F liquid 176°F 0.01 Maximum operating pressure 145 psi 0 Flange standard: USA Sweat Type of connection: Bronze Sweat 6 3/16" Pipe connection: 1/2"Sweat 5 1/2" Pressure stage: 10 Port-to-port length: 5 in Liquid: Liquid temperature range 35.6.. 150.8°F Density: 62.4 Ib/ft' Electrical data: Number of poles: 2 Max.power input: 85 W Rated power-P2: 0.04 HP Main frequency: 60 Hz { Rated voltage: 1 x 115 V Current in speed 3 0.74 A iv Capacitor size-run 10 pF/180 V �— Insulation class(IEC 85): F Cl) Motor protection: CONTACT Thermal protec: internal Controls: Pos term box: 9H Others: Gross weight: 6.5 lb Printed from Grundfos CAPS[2011.05.069] G Ink U N ED FO S'M 3/4 Company name: - ` Created by: ■� Phone: G ■t V N ��S ` Fax: - Date: - 59896212 UP 15-18 B5/TLC 60 Hz 6 3/161I 5 1 /21I O LO 0 I M N C'7 Note!All units are in[mm]unless others are stated. Disclaimer:This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS[2011.05.069] GZ UPI IV�FOS'N 4/4 MOEN@ S p e ci f i c a t i o n s COMMERCIAL DESCRIPTION • Brass construction with chrome plated finish • 1/2"IPS connections • 8"centers • Vandal resistant torx head screws OPERATION • Wrist blade style handles with hot and cold color indicators FLOW • Water usage is limited to these maximum flow rates as indicated by the corresponding product markings '1.5 gpm max(5.7L/min)at 60 psi CARTRIDGE • Brass shell,ceramic disc cartridge • 1/4 turn operation STANDARDS Two-Handle Kitchen Faucet • Third party certified to ASME Al 12.18.1/CSA B125.1 and all applicable specifications referenced therein • Certified to NSF 61/9&372 Model' 8289 • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act • ADA ® for lever handles WARRANTY • Warranted for 5 years against material or manufacturing defects NOTE:Designed to be installed through 2 or 3 holes- 1"min.dia.and on 8"on center 8-1/2" 12" (216mm) (305mm) 16" (407mm) 2-1/4"� 8" (57mm) (204mm) 4-1/4" (108mm) 2-1/8" (54mm) r 10-1/4" (260mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.4/16 www.moen.com MOEN@ S p e ci f i c a t i o n s COMMERCIAL DESCRIPTION • Solid brass construction • Chrome,Brushed Chrome or Brushed Nickel finish • 1/2"IPS connections • Solid brass waterways OPERATION • Lever handle • Temperature controlled through 1 10'arc of handle FLOW Standard aerator is limited to 2.2 gpm max.(8.3 L/min) Single Handle Lavatory Faucet CARTRIDGE • Ceramic disc cartridge*(with temperature limit stop) • Nonmetallic/nonferrous and ceramic material WATERSENSE STANDARDS MODEL FLOW(gpm) DRAIN FINISH CERTIFIED • Third party certified to WaterSense°(only applies to 1.5 gpm), 8413 2.2 without Chrome ASME All 12.18.1/CSA B125.1,and all applicable requirements 8413F15 1.5 without Chrome x referenced therein including NSF 61/9 84131`05 0.5 without Chrome • Contains no more than 0.25%weighted average lead content 84131`03 0.35 without Chrome • Complies with California Proposition 65 and with the Federal Safe 8414 2.2 Metal Chrome Drinking Water Act 8414BC 2.2 Metal Brushed Chrome • ADA ® for lever handles 8414BN 2.2 Metal Brushed Nickel WARRANTY �atier5e��� • Warranted for 5 years against material or manufacturing defects r' o s EPA G� : See table above I NOTE: This faucet is designed to be installed thru 3 holes, 1"min.dia. HOT COLD 55' 55' 7" (128mm) 6" (153mm) a d 111 1 6-5/8" 5-5/8" O y__ (168mm) (143mm) 2-1/2" 5" (64mm) (127mm) I I LI-1/8"MAX. (29mm) 2" 2" (51mm) (51mm) 2-7/16" ^(62mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.9/12 www.moen.com MOEN@ Specifications COMMERCIAL 00 FAUCET DESCRIPTION • Brass construction,rough chrome finish • Integral vacuum-breaker • 3/4"Garden hose threaded spout • 1/2" IPS eccentric connections • "Service stops" • "Wall mounting bracket" • Vandal resistant torx head screws OPERATION • Lever style handles with hot and cold color indicators FLOW • Unrestricted CARTRIDGE • Brass shell ceramic disc cartridge Two-Handle Service Sink Faucet • 1/4 turn operation STANDARDS Model:8230 (Chrome) • Third party certified by IAPMO and CSA to meet ASME Al 12.18.1 M and all applicable specifications referenced therein • ADA® for lever handles WARRANTY • Warranted for 5 years against material or manufacturing defects 1-1/4" 1 -I Flange (32mm) 1 1 7/8"x 1-3/4" E 9-3/8" #12, 1-1/21, O OF (22mmx44mm) (238mm) c Flathead Wood Screw 3/4" Eccentrics (19mm) CENTERS ADJUST FROM FINISHED 9-1/2" 7-5/8"(1 94mm)TO 8-3/8"(213mm) ; WALL (241mm) 2-1/2" 4" Vacuum (64mm) (102mm) Breaker Cla 3-1/4" (82mm) o 2" A- n y F3/4"Hose 1/4 TURN 2-3/8" Threads STOP (60mm) DIAMETER 1/2"INLET 5-7/8" (150mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.6/13 www.moen.com ELM MUSTEE 27F and 27W UTILATWIN° Preferred by the"Pros" Laundry/Utility Tubs — Premier SEE PAGE 2 FOR A LIST OF Design features: • High strength, one piece molded construction ■ Produced with Mustee's proprietary structural thermoplastic resins and innovative cellular molding process creating extreme strength&durability • Includes Twin-Drain Waste connector which joins drain assemblies to assure rapid and uniform waste water discharge...includes washers,slip nuts and stoppers. ■ Divider wall between tubs is recessed one inch, permitting water to 4 overflow from one tub to other, prevents water spilling onto floor. • Large,self-draining back shelf with retainer curb that prohibits water run- off except into tub. ■ 19 Gallon capacity per tub,extra deep 13"tubs with smooth surfaces ■ Connects to standard 11/2" P or S trap ■ Accommodates single or dual-handle faucets.4" or 8"centers ■ Floor model includes heavy gauge steel legs with adjustable levelers ■ Wall model includes wall mounting bracket, side supports and mounting hardware for securing tub to concrete or stud wall ■ Mold and mildew-resistant components ■ Easy to assemble and install ■ Color-fast white finish Code Accepted: UTILATUBO and UTILATWINO Laundry/Utility Tubs meet or exceed performance requirements as listed: c o ■ International Association of Plumbing and Mechanical Officials(IAPMO)O Listed W • Warnock HerseyO(Canada) Listed—CSA test standards: Laundry Tray-#645.0 and#1345.5; Drain -#13125 Intertek ■ American National Standards Institute(ANSI)—Specification Z 124-2011 ANSI Specifications Colors & Models: Model Mounting H x W x D UPC White 27F Floor 34" x 40" x 24" 6 71031 00057 6 White 27W Wall 34" x 40" x 24" 6 71031 00058 3 MOUNTING 8gA0 General: Furnish and install as shown on plans, UTILATWIN@ Twin Laundry/Utility 194 Tub model (27F,27W),as manufactured by E.L.Mustee&Sons, Inc.Tub shall 143/8' a�" be one-piece molded construction using structural thermoplastics with matched metal molds under extreme heat and pressure.Tub to include integrally molded 34" drains,twin drain waste coupling, recessed divider wall between tubs and twin 34" q Aqqqox. A,q�x PA E G drain assembly for connection to standard 1-112"P or S-trap,stoppers and wall AOJ/NGT ENT ROOq 2a mounting hardware or heavy gauge steel legs with built-in levelers. 19 gallon 40" capacity per tub,each tub 13"deep.Shall meet ANSI Z 124-2011.Color:White. wr w mil Weight:27F 40 lbs.;27W 40 lbs. ELM ,Y,USTEE E-mail:info@ usteelcom. • Web:www.mtustee com - Proudly mh Street - Brook Park,ade in the USA hone:216.267.3100 • Fax:216.267.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. ElM ® MUSTEE 27F and 27W UTILATWIN° Preferred by the"Pros" Laundry/Utility Tub Accessories Faucet �i Faucet Block For use with overhead water supply AA'.I�IR !1'A 11 Allr,t h,r11 HandiFlo- Fitting NAtiL•r.,i NA't. Faucet Model No. UPC 93.600 6 71031 00232 7 g Chrome finish,4"center set brass faucet. 7"swing spout with aerator, level handles, replaceable seats and stems.Areator or hose end. Faucet Block Model No. UPC 20.600 6 71031 00031 6 Used when water supply lines are above the tub. Mounts to tub shelf when using a clamp-on faucet. HandiFlo' Fitting Model No. UPC 94.700 6 71031 00287 7 Dispenses water from washing machine discharge hose into laundry tub. Eliminates draping washer machine hose over back/side wall of laundry tub and conceals discharge hose. Mounts to back or side wall of laundry tub, includes mounting hardware. E�M MUSTEE E-mail:info@ usteelcom. 5 Web:www.mustee.com - Proudly made n the USA ne:216.267.3100 • Fax:216.267.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. EI.M ® MUSTEE Mop Service Basin — Model 63M Preferred by the"Pros" SEE PAGE 2 FOR A LIST OF ACCESSORIES! Design features: ■ All Mustee basins are one-piece molded from high impact resistant 7mm7 DURASTONE®structural fiberglass(24"x 24") • Integral,molded-in drain for connection to 3"ABS,PVC(Sch.80) X or cast iron ■ Available drain seals for connection to 2"pipe or 3"soil pipe • Complete range of accessories to meet specific application needs ■ Colorfast marbleized white finish • Easy to install Code Accepted Mustee Mop Service Basins meet or exceed performance requirements as listed: ■ International Association of Plumbing and Mechanical Officials(IAPMO)®Listed O • Warnock Hersey'(Canada) Listed—CSA test standards: Mop Basins-#1345.0 ■ American National Standards Institute(ANSI)-Specification Z 124-2011 ,a,nn�►S�I • American Society of Testing and Materials(ASTM) D 635 E 84 and E 162 ■ CAN/ULC S102-07 Burn and Smoke Test Specifications Model Number Model H x W x D UPC 63M White 10" x 24" x 24" 6 71031 00189 4 General:Furnish and install as shown on plans,Mop Sectional View Top View Service Basin model 63M,as manufactured by E.L. �24" Mustee&Sons,Inc.Unit to be one-piece molded J..1 fiberglass made with matched metal molds using �� 12" extreme heat and pressure.Height shall be 10"with not 24" less than 1"wide shoulder.Size 24"x 24"Drain shall be integrally molded,complete with drain seal for installation T 12" of 3"ABS,PVC(Sch.#80)and iron pipe.Removable stainless steel strainer.Performance tested to meet or I j exceed ANSI Z 124-2011 and FHA/HUD UM-73.Weight 45 �24 lbs.,cubic feet 4.2.Install in compliance with local codes. Lj E�M o Mustee nfo@ usteelcom. Web:5 www.mest tustee com Proudly made Br n the USA 4142 Phone:216.267.3100 • Fax:216.267.9997 MUSTEE E-mail: Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. E M MUSTEE Mop Service Basin — Model 63M l Preferred by the"Pros" Accessories 011, Service Faucet Model No. UPC 63.600A 6 71031 00277 8 Heavy duty, chrome plated brass dual handle sink faucet with top reinforcing bar and pail hook on spout. 00- Hose and Hose Holder Model No. UPC 65.700 6 71031 00196 2 Heavy duty 5/8"dia. reinforced 31" rubber hose with brass couplings on one end. Spring loaded, molded rubber hose holder mounts on stainless steel wall plate. Mop Hanger Model No. UPC 65.600 6 71031 00195 5 Vol X'W �l I Three spring-loaded rubber holders mounted to a 3"x 24" stainless steel wall plate. Click here for more information. 001, Bumper Guards Available in high impact resistant molded vinyl(3 versions)or stainless steel(2 versions). 77 Model No. UPC High Impact-resistant vinyl 63.401 20-3/4" Long 6 71031 00290 7 Stainless steel 63.403 20-3/4" Long 6 71031 00409 3 000- DURAGUARD"m Wall Guards Protects wall surfaces from splashing and damage from impacts, 12"height,20 gauge#304 stainless steel. Model No. UPC 67.2424 Two panels&bracket for 24"x 24"corner 6 71031 00293 8 67.24C One panel&corner bracket 6 71031 00295 2 001, Optional Seals For installations with the following pipe connections: Model No. UPC 7wj 65.308 For 2" PVC,ABS and iron 6 71031 00303 4 65.309 For 3" PVC,ABS and iron,(Included w/mop basin) 6 71031 00304 1 65.311 For 3"soil pipe(No-Hub) 6 71031 00305 8 E�M o MUSTEE E-mail:info@ usteelcom. 5 Web:www.mtustee com - Proudly made n the USA ne:216.267.3100 • Fax:216.2600k Park,OH 442 - 7.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. Residential Electric ' Water Professional Prestige Water Heaters The new degree of comfort® Professional Prestige° electric water heaters offer a diagnostic system with leak protection ila and a 12-year warranty Efficiency Features • .93 UEF • High performance and lower • Isolated tank design reduces operating cost conductive heat loss •Compliant with many electric utility • Dual 5500 watt stainless steel heating incentive programs elements • Premium grade anode rod provides Performance long-lasting tank protection • FHR: 56-63 gallons based on gallon ' Electric junction box located above capacit Y heating elements for easy installation • Recovery: 25 GPH at a 90°F rise** 'Over-temperature protector cuts off power in excess temperature Super Sentinel Diagnostic situations System Plus... •Simple easy to read diagnostics • EverKleen"self cleaning device fights •Controls multiple operating modes harmful sediment build-up with a • Digital thermostat setting high-velocity spiraling water stream— helps operating efficiency by saving • Built-in water sensor alert with audible energy, money and improving tank life alarm and service notifications . Enhanced-flow brass drain valve •Temperature and pressure relief valve 0 EcoNet` included • Low lead compliant • EcoNet®WiFi-connectedt Warranty Professional Prestige technology and free • 12-Year limited tank and parts 40 and 50-Gallon Capacities mobile app gives users warranty* 240 Volt AC/Sin le Phase control over waterg systems, allowing for `See Residential Warranty Certificate for Electric complete information customizable temperature,vacation t WiFi broadband internet connection required settings,energy savings and system monitoring at home or away. Units meet or exceed ANSI requirements and have UL Visit Rheem.com/EcoNetConnect been tested according to D.O.E.procedures.Units meet or exceed the energy efficiency requirements •Water sensor detects water outside of NAECA,ASHRAE standard 90,ICC Code and all LEED Point=7 of the unit and sends an alert via state energy efficiency performance criteria. the free EcoNet®mobile app to the homeowner • EcoNet®WiFi Kit included See specifications chart on back. _D, INTEGRATED HOME COMFORT PRINTED IN U.S.A.12/17 WP FORM NO.PROPE RH Rev.4 Residential Electric ' Water Professional Prestige II Water Heaters The new degree of comfortm Professional Prestige° Electric Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO. T UEF UNIFORM Y NOMINAL RATED FIRST HOUR RECOVERY TANK HEIGHT TO APPROX ENERGY P GALLON GALLON MODEL RATING IN G.P.H. T.HEIGHT WATER CONN. DIAMETER SHIP W FACTOR E CAPACITY CAPACITY NUMBER G.P.H. 90'F RISE A B C (LBS.) (UEF) Tall 40 36 PROPE40 T2 RH95 EC2 56 25 60-3/4 63-5/8 18-1/4 105 0.93 Tall 50 45 PROPE50 T2 RH95 EC2 63 25 58-5/8 61-5/8 20-1/4 121 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. Super Sentinel not available on single element models,available on dual element models only.Super Sentinel not 8" available in excess of 5 kW on 208 V models. •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 5500 watt upper and lower heating elements. **Recovery=wattage/2.42 x temp.rise°F. Example: 550OW =25 GPH HOT 2.42 x 90' WATER �° CONNECTION COLD **Recovery calculations used are based on 5500 watt WATER elements used in non-simultaneous operation. RELIEF VALVE CONNECTION CONNECTION � ANODE ROD C� DIAMETER Q B WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com INTEGRATED HOME COMFORT PRINTED IN U.S.A.12/17 WP FORM NO.PROPE PH Rev.4 Residential Electric ' Water Professional Classic Point-of-Use Water Heaters The new degree of comfort:" Professional Classic° Point-of-Use electric water heaters feature a space-saving design for installation in limited spaces - Efficiency Warranty • .92 UEF for 30-gallon model •6-Year limited tank and parts •Single resistored stainless steel warranty." 2.5-Gallon heating element 'See Residential Warranty Certificate for complete information Features Units meet or exceed ANSI requirements and have • High efficiency heating element been tested according to D.O.E.procedures.Units meet or exceed the energy efficiency requirements •Over-temperature protector cuts off of NAECA,ASHRAE standard 90,ICC Code and all power in excess temperature situations state energy efficiency performance criteria. •Automatic thermostat keeps water at desired temperature •Wall bracket for easy wall mount installations and corrosion resistant 1/4 turn drain valve included with 2.5 gallon model 6,t0,t5,is.s and 30-Gallon Plus... Professional Classic •Temperature and pressure relief valve Point-of-Use • Exclusive Rheemglas®tank lining resists corrosion and prolongs tank life 2.5, 6, 10, 15, 19.9 and NOT WATER COLD WATER 30-Gallon Capacities • Meets or exceeds National Appliance CONNECTION CONNECTION ANOOE Energy Conservation Act(NAECA) p NDT "OD 120 Volt AC WATER requirements OUTLET � 2-Wire Single Phase RELIEF VALVE •These units are U.L. listed and comply CONNECTION Electric with Underwriter's Laboratories �ETER 1 RELIEFVALVE Specifications 174 ABD A W coL` U I ® L1�R ° • Enhanced-flow brass drain valve on B 2.5-gallon model e Low lead compliant WAEF VALVE CONNECTIONSTIONS IONSVALL—P N.P.T. s,10,15,19.9 AND 2-1/2 GALLON MODEL 30 GALLON MODELS DESCRIPTION ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO. T HEIGHT TO HEIGHT HEIGHTTO UNIFORM Y NOMINAL RATED TANK HOT WATER TO SIDE T&P COLD WATER APPROX. ENERGY P GALLON GALLON MODEL HEIGHT OUTLET DIAMETER VALVE INLET SHIP WT. ENERGY FACTOR E CAPACITY CAPACITY NUMBER A B C D E (LBS.) FACTOR (UEF) POU 2.5 - PROE2 1 RH POU 14 14 9-3/4 - - 22 - - POU 6 - PROE61 RH POU 15-1/4 12-1/2 15-3/4 11-1/2 4-1/4 36 - - POU 10 - PROE10 1 RH POU 23 20-1/2 15-3/4 19-1/2 4-1/4 46 - - POU 15 - PROE15 1 RH POU 24-1/4 22 17-3/4 21 4-1/2 54 - - POU 19.9 - PROE20 1 RH POU 25-1/4 22-3/4 19-3/4 21-3/4 5 69 - - POU 30 27 PROE30 1 RH95 POU' 31-7/8 23-1/8 22-1/4 23 3 91 0.95 0.92 Uniform Energy Factor,Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. 'For double element,substitute"2"suffix for'1".Not available in 120 volt.Available with 2-wire(single phase)outlet only.(6000 watt max.). • 2.5 gallon model:12"N.P.T.inlet and outlet.Relief valve connection 3/4". Available with 120 or 240 volt AC single phase only,120v(1440w)240v If 500w) Power cord supplied with 120 volt models only. • 6 through 30 gallon models:3/4"N.P.T.outlet,inlet,anode rod.T&P valve connections.Not available with 3 phase wiring. Water heaters furnished standard with 120 volt AC,2000 watt single element. Special wiring options-a limited number of wiring options are available.Consult factory for price and availability. CONSTRUCTION DETAILS:The cold water enters the tank a few inches from the bottom.Both hot and cold water lines may be connected directly to the water heater without special nipples or tees.The relief valve simply screws into the opening provided. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery,Alabama 36117-4305 • www.rheem.com INTEGRATED HOME COMFORT PRINTED IN U.S.A.04/17 WP FORM NO.PRIDE RHPOU N Rev.1 ADJUSTABLE FLOOR DRAIN FINISH FIXTURE 11832 SERIES FinishLine" ITEM#SUBMITTED JOB NAME SPECIFICATION Sioux Chief 832 Series FinishLine finish fixture for adjustable floor drain shall be LOCATION used where necessary in drainage systems. Finish Fixture shall allow adjustment ENGINEER of 1.25" after the concrete pour when used with FinishLine rough-in fixtures. Strainer shall be heel-proof and meet all applicable load requirements for CONTRACTOR intended use. Designed in accordance with ASME A112.6.3 Po# TAG MATERIALS Top Housing:ABS with threaded brass inserts Strainer:ABS — 1 LOAD RATING = 500 Ibs(Light Duty, pedestrian traffic) STRAINER FREE AREA 8.74" two DIMENSIONS A: Top diameter 61/2" 832-4HPR B: Overall height 27/8" C: Outlet diameter 4" A i B 1 �c- 832-4HPR SkxjxChM Sioux Chief Manufacturing Company I P: 1.800.821.3944 F: 1.800.758.5950 I www.siouxchief.com ROYAL@ MANUAL FLUSHOMETER SL❑AN. ROYAL 186-1.0 CODE NUMBER 3012636 DESCRIPTION 1—row, fi 1.0 gpf, Polished Chrome Finish, Fixture Connection Top Spud,Single L",y Flush, Royal® Exposed Manual Urinal Flushometer. DETAILS • Flush Volume: 1.0 gpf(3.8 Lpf) • Finish: Polished Chrome(CP) • Valve: Diaphragm r • Valve Body Material: Semi-red Brass • Fixture Type: Urinal • Fixture Connection:Top Spud • Rough-In Dimension: 11 1/2" (292mm) COMPLIANCES & CERTIFICATIONS • Spud Coupling:3/4" (19mm) • Supply Pipe: 1/4" (19mm) FEATURES (ADA Compliant, cUPC Certified, BAA Compliant) • PERMEX@ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass RECOMMENDED SPECIFICATION • Sweat Solder Adapter with Cover Tube&Cast Wall Flange with Set Valve Body, Cover,Tailpiece and Control Stop shall be in Screw conformance with ASTM Alloy Classification for Semi-Red • Non-Hold-Open Handle, Fixed Metering Bypass and No External Brass.Valve shall be in compliance with the applicable Volume Adjustment to Ensure Water Conservation sections of ASSE 1037 and ANSI/ASME 112.19.2. • Diaphragm, Handle Packing and Vacuum Breaker to be molded VALVE OPERATING PRESSURE (FLOWING) from PERMEX® Rubber Compound for Chloramine Resistance 15-80 PSI (103-552 kPa). Specific fixtures may require greater • ADA Compliant Metal Oscillating Non-Hold-Open Handle minimum flowing pressure-consult manufacturer 3/4" I.P.S. Screwdriver Bak-Chek@ Angle Stop w/Free Spinning Vandal requirements. Resistant Stop Cap DOWNLOADS VIDEOS • Royal Exposed Installation Instructions • Control Stop Repair and Maintenance Guide PVD Special Finishes • Flush Connections Flanges Repair and Maintenance Guide • Tail Piece Repair and Maintenance Guide • Royal Manual Diaphragm Flushometer Repair and Maintenance Guide • Flushometer Pressure gauges • Additional Downloads NOTES All information contained within this document subject to change without notice. Looking for other variations of the ROYAL 186 product?View the general spec sheet with all options. Find a compatible urinal for this flushometer. Find a compatible water closet for this flushometer. Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3012636 • Downloaded 11/17/20 • Revised 07/28/20 •View Latest Version Page 1 of 2 ROYAL@ MANUAL FLUSHOMETER SLOAN@ ROYAL 186-1.0 ROUGH-IN �- 21/4"MIN. (57mm) I.P.S. SUPPLY o =Dr1*0 SUPPLY 43/4" (DN 20mm) 111/2" (121 mm) (292mm) CENTERLINE OF FIXTURE CENTERLINE OF WASTE FIN. F_ FIN. FLOOR WALL Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3012636 • Downloaded 11/17/20 • Revised 07/28/20 •View Latest Version Page 2 of 2 L13 RegalO XL Flushometers ® Ill-XL ► Code Number 3080053 `L ► Description Exposed Water Closet Flushometer,for floor mounted or wall hung - top spud bowls. I ► Flush Cycle 1.6 gpf/6.OLpf ► Specifications Quiet,Exposed,Diaphragm Type,Chrome Plated Closet Flushometer with the following features: • ADA Compliant Metal Oscillating Non-Hold-Open Handle • 1"I.P.S.Screwdriver Bak-ChekO Angle Stop • Control Stop Plug • Sweat Solder Adapter with Cover Tube • Cast Wall Flange with Set Screw • Vacuum Breaker Flush Connection • Non-Hold-Open Handle and No External Volume Adjustment to Ensure Water Conservation �-21/4"MIN. (57 mm) • Low Consumption flush accuracy controlled by Para-FIOTM O 1"I.P.S. Technology SUPPLY • High Copper,Low Zinc Brass Castings for Dezincification o �43/4"— (DN 25 mm) Resistance (121 mm) Valve Body,Cover,Tailpiece and Control Stop shall be in 11 1/2" CENTERLINE conformance with ASTM Alloy Classification for Red Brass.Valve 292 mm) OF FIXTURE shall be in compliance to the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2. ► Accessories (Sold Separately) ❑ See Accessories Section of the Sloan catalog for available accessories CENTERLINE OF WASTE 0- Fixtures FIN. Consult factory for matching Sloan brand fixture options. FLOOR FIN. WALL ► Compliance&Certifications ® USA This space for Architect/Engineer Approval SLOAN 10500 SEYMOUR AVE.•FRANKLIN PARK,•IL.60131 Ph: 1-800-9-VALVE-9 or 1-847-671-4300•Fax: 1-800-447-8329 or 1-847-671-4380•http://www.sloan.com 2017-24-04 Page 1 of 1 T&S BRASS AND BRONZE WORKS, INC. Model No. 2 Saddleback Cove/ P.O. Box 1088 13-0230 Travelers Rest, SC 29690 UL . REG.#A2601 Item No. BO#9001 Travelers Rest SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity ADA Compliard Customer/Wholesaler Contractor Architect/Engineer 1811 2 3/8" [457mm] [60mm] Eterna Cartridges & 065X Lever Handles w/ 18" Swing Nozzle w/ Color Coded Indexes B-PT Stream Regulator Outlet 1- Mounting 91/2„ Surface [241 mm] J­ 6 3/4" 0211 [172mm] [51�mm] w/ 1/2 NPT Female Inlet 8" c/c [203mm] Adjustable from 7 3/4" to 8 1/4" [197mm to 210mm] Note: Rough-In Requirement (2) O 1" [25mm] Mounting Holes Product Specifications: Drawn Checked Approved Double Pantry Faucet w/ Eterna Cartridges, 18" Swivel Nozzle MIL JRM JHB w/ B-PT Stream Regulator Outlet, Lever Handles & 1/2" NPT Date: Female Inlets scale: 1:8 02/ 17/ 11 Sheet: l of 2 rip Ilp T&S BRASS AND BRONZE WORKS, INC. Model No. 2 Saddleback Cove/ P.O. Box 1088 &0230 Travelers Rest, SC 29690 U` . PM.#A2601 Item No. so#9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com ITEM SALES NO. DESCRIPTION NO. 1 065X 18" Swing Nozzle Assembly w/ B-PT Stream Regulator 2 B-PT Stream Regulator 3 001048-45 Nozzle Tip Washer 4 000922-45 Lever Handle Screw 5 001661-45 Red Index-HW 6 001638-45 Lever Handle 7 005960-40 Spindle Asm, Eterna "Hot" 8 009538-45 Swivel Washer 9 011429-45 Swivel Sleeves (2) 10 001074-45 O-Ring 11 001660-45 Blue Index-CW 12 005959-40 Spindle Asm. Eterna "Cold" 13 001019-45 Coupling Nut Washer 14 OOAA 1/2" NPT Female Inlet Assembly 3 5 8 2 6 9 10 1 7 11 12 ® -� 13 14 Product Specifications: Drawn Checked Approved Double Pantry Faucet w/ Eterna Cartridges, 18" Swivel Nozzle DHL JRM JH$ w/ B-PT Stream Regulator Outlet, Lever Handles & 1/2" NPT Female Inlets Scale: Date: NTS 02/ 17/ 11 Sheet: 2 of 2 GENERAL PLUMBING NOTES PLUMBING LEGEND PLUMBING LEGEND 1. THE FOLLOWINGPIPES NOTES APPLY TO ALL PLUMBING DRAWINGS.ADDITIONAL PLUMBING 13. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS 27. PPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM SYMBOL DESCRIPTION SYMBOL DESCRIPTION NOTES MAY BE INDICATED ON EACH PLUMBING DRAWING.SEE SPECIFICATIONS FOR OF PLUMBING EQUIPMENT(VOLTAGES,ETC.). PPE SECTIONS. ADDITIONAL REQUIREMENTS. PIPING GENERAL 14. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY 28. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT HOW PIPING OFFSETS 2. INSTALLATION HALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS WHICH MAY BE REQUIRED. (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, FLOW ARROW CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 26 29. PATCH ALL FLOOR, WALL,CEILING AND ROOF OPENINGS CREATED/CAUSED BY THE NORTH NORTH ARROW O SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL ELECTRICAL PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY DEMOLITION OF EXISTING PIPES, FIXTURES, ETC. IN ACCORDANCE WITH DIVISION 1 Imo- CAP OR CLEANOUT TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH SERVE EQUIPMENT. OF THE SPECIFICATIONS. CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. O- PIPE UP OR TEE UP AND DOWN 15. SECURE WATER HEATERS AND STORAGE TANKS AND PLUMBING EQUIPMENT TO 30. ALL WATER PIPING IN UNHEATED SPACES EXCEPT CIRCULATED HOT WATER SHALL SECTION IDENTIFICATION 3. INSTALL ALL WASTE LINE CLEANOUTS IN ACCORDANCE NTH CHAPTER SEVEN OF STRUCTURE AS REQUIRED BY CODE. REFER TO THE STRUCTURAL DRAWINGS FOR BE HEAT TRACED AND INSULATED. C PIPE DOWN A THE UNIFORM PLUMBING CODE: ADDITIONAL SPECIAL REQUIREMENTS RELATED TO THE PLUMBING INSTALLATION. LIA M201 A.3"WASTE PIPE-3"CLEANOUT WITH 2.5"PLUG 31. WHERE PIPE SIZES ARE NOT SHOWN ON DRAWINGS,SIZE PIPING PER THE UNIFORM � PIPE TEE UP B.4"WASTE PIPE- e CLEANOUT WITH 3.5°PLUG 16. PROVIDE PLUMBING ANCHORAGE AND EXPANSION EVERY 100' PIPE LENGTH PER PLUMBING CODE. SHEET IDENTIFICATION C.6"WASTE PIPE-4"CLEANOUT WITH 3.5°PLUG CODE. PIPE TEE DOWN 32. PRIOR TO SUBMITTING ALL PLUMBING FIXTURES THE CONTRACTOR SHALL VERIFY 4. WASTE,VENT AND SUPPLY PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SHALL 17. ACCESS PANELS ARE REQUIRED AT ALL CONCEALED VALVES AND EQUIPMENT. COMPATIBILITY OF THE SPECIFIED FIXTURE WITH THE SIZES OF FINISH CABINETRY 45'DEGREE ELBOW O SHEET NOTES BE AS SHOWN ON PLUMBING FIXTURE SCHEDULES.BELOW GRADE SANITARY WASTE COORDINATE LOCATION AND SIZE WITH ARCHITECT. AS IDENTIFIED IN GENERAL CONTRACTOR'S SHOP DRAWINGS. ANY DISCREPANCIES HV Engineering,Inc. PIPING SIZES SHALL BE AS SHOWN ON PLANS AND FIXTURE SCHEDULES AND BETWEEN THE SIZE OF THE FIXTURES SPECIFIED AND THE FINISH CABINETRY SIZES L 90'DEGREE ELBOW O (RISER it on RISER CALLOUT csulting Engln- SHALL NOT BE LESS THAN 2"DIAMETER. 18. STUB OUT TO SITE SERVICES 5' OUTSIDE BUILDING FOUNDATION. PIPE SIZE, SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE Hall Creek Office Park FIXTURE UNITS,AREA DRAINED, INVERT ELEVATION, SIZES,AND SQUARE FOOTAGES SUBMITTAL. 4 WAY TEE C 6912 220th St.SW,Suite 303 5. ALL SANITARY SEWER PIPING BELOW SLAB SHALL BE INSTALLED AT A MINIMUM OF AS INDICATED. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING a PLUMBING FIXTURE TAG(WC11 Mountlake Terrace,WA 98043 1/4° PER FT SLOPE UNLESS APPROVAL IS PROVIDED BY THE "ADMINISTRATIVE WORK. 33. PLUMBING VENTS SHALL TERMINATE A MINIMUM 10' FROM OUTSIDE AIR INTAKES, AUTHORITY" IN WRITING FOR A SHALLOWER SLOPE. IN NO CASES SHALL SEWER PER CODE. TEE Phone:(206)706-9669 PIPING BE INSTALLED AT LESS THAN 1/8" PER FT SLOPE. IN NO CASES WILL 19• INSULATE PIPING PER WSEC AND PER DIVISION 22 SPECIFICATIONS(WHICHEVER IS zi, REVISION CALLOUT(REV-1) w hNongineenno.ol� PIPING SMALLER THAN 4" BE INSTALLED AT SLOPES SHALLOWER THAN 1/4" PER GREATER). 34. LABEL ALL PIPING SYSTEMS PER THE IMC AND UPC. PIPE BREAK ''^-�j FOOT. PIPING INSTALLED AT 1/8-/FT HALL BE RESIZED PER CHAPTER 7 OF THE 20. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW 35. SUPPORT AND BRACE PIPING SYSTEMS IN ACCORDANCE WITH UPC SECTION 314 `-N._.-N-'" REVISION BUBBLE UNIFORM PLUMBING CODE AND SUPPORTING CALCULATION SUBMITTED TO ENGINEER DUCTWORK AND BETWEEN LIGHT FIXTURES.ADJUST AS NECESSARY. AND AS REQUIRED IN THE SPECIFICATIONS. FOR REVIEW. PIPING SPECIALTIES 21. PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM 36. ALL MATERIALS IN CONTACT NTH PIPING SYSTEMS HALL BE COMPATIBLE FOR a DETAIL CALLOUT(X/PX.XX) Project 6. PROVIDE STOPS PRIOR TO ALL PLUMBING EQUIPMENT. THIS SHALL ALSO INCLUDE USE WITH AND FOR CONTACT WITH THE PIPING MATERIAL. CONTRACTORS AND PROVIDING INTEGRAL STOPS ON ALL SHOWER AND TUB/SHOWER VALVES(WHETHER ACCESS OF 6° IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18" TO TRADES SHALL VERIFY COMPATIBILITY OF THEIR PRODUCTS WITH THE PIPING PRESSURE GAGE TENANT IMPROVEMENT: THE SIDE OF CABLE TRAYS. PROCESS SOLUTIONS SPECIFIED OR NOT). PROVIDE WASTE TRAPS AT ALL DIRECT CONNECTED SYSTEMS.THIS INCLUDES,BUT IS NOT LIMITED T0,FIRE STOPPING SEALANTS,FIRE �- � COLUMN GRID SYMBOLS EQUIPMENT IN ACCORDANCE WITH CODE AND THE SPECIFICATIONS. 22. COORDINATE LOCATIONS OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES OVER STOPPING COLLARS, VIBRATION ISOLATION ELEMENTS, THERMAL INSULATION, - _+ -_-_-_- LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT EXPANSION JOINTS AND ANY MATERIAL IN CONTACT WITH PIPES. THERMOMETER A 7. PROVIDE TRAP PRIMERS AT ALL FLOOR DRAINS UNLESS NOTED OTHERWISE. MAINTENANCE. Location PROVIDE UNION ON UPSTREAM AND DOWNSTREAM SIDE OF ALL TRAP PRIMERS. 37. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE �-SIGHT GLASS 6 TRAP PRIMER BRANCH TAKEOFF SHALL BE FROM TOP OF MAIN DISTRIBUTION PIPE. 23. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY FLOORPLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE NSF INTERNATIONAL ���VENTURI FLOW METER O GENERAL MECHANICAL NOTES 17216 51 st Ave NE, 8. INSULATE P-TRAPS EXPOSED IN UNHEATED SPACES. ROUTING ONLY. NUMBER IDENTIFICATION Industrial Park,Building B 38. PIPE BURIAL METHODS FOR BELOW GRADE PIPING SHALL COMPLY WITH MFR 9. SEE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE ROUGH-IN DIMENSIONS 24. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY INSTALLATION INSTRUCTIONS,ASTM D 2321 AND ASTM F1668. FAILURE TO FOLLOW ROW METER FLAG MECHANICAL NOTES Arlington,WA 98223 AND OTHER DETAILS. ALSO SEE ARCHITECTURAL DRAWINGS FOR FINISH ' THESE REQUIREMENTS CAN LEAD TO PIPE FAILURE. NUMBER IDENTIFICATION REQUIREMENTS N ALL PLUMBING FIXTURES INCLUDING REQUIREMENTS S MANUFACTURERS INSTALLATION INSTRUCTIONS,AS INDICATED ON DRAWINGS,OR IN FLUSH SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL -� Prepared For LEVER LOCATION AT AD COMPLIANT TOILETS AND VALVE LOCATIONS OF ADA MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN 39. ROOF MOUNTED PIPING SHALL BE INSTALLED ON FREE FLOATING, PREFABRICATED MANUAL AIR VENT(MAV) EXISTING WORK OR BACKGROUND p SHOWERS.REPORT ALL DISCREPANCIES TO ENGINEER PRIOR TO ANY WORK. INSTITUTE OF STEEL CONSTRUCTION(AISC)MANUAL SUPPORTS SIMILAR TO MIRO MODEL 24-R OR ROOF TOP BLOX ON WALKWAY INFORMATION(LIGHT UNE NEW WORK (HEAVY LINE; Bond Plumbing, LLC 10. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE PLUMBING TREAD PADS.THE USE OF WOOD FOR SUPPORTS IS PROHIBITED. �GAS PRESSURE REGULATOR R 25. IF REQUIRED FOR INSTALLATION OF PIPES AND EQUIPMENT, PROVIDE ADDITIONAL RELOCATE EXISTING EQUIPMENT ITEM FIXTURES AT HEIGHTS SHOWN ON ARCHITECTURAL ROOM ELEVATIONS. 40. ALL ITEMS IN CONTACT WITH POTABLE WATER SHALL COMPLY WITH THE NATIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO "REDUCTION OF LEAD IN DRINKING WATER ACT"5.3874. MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL - �WATER METER OR DEVICE INDICATED 11. PLUMBING DRAWINGS SHOW APPROXIMATE LOCATIONS OF PLUMBING FIXTURES. 19023 36th Ave W.Suite G REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. COORDINATE FLOOR MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. EXISTING EQUIPMENT OR PIPING DRAINS FOR MECHANICAL SPACES WITH MECHANICAL EQUIPMENT BEING SERVED. ---- � WYE STAINER TO BE SELECTIVELY DEMOLISHED Lynnwood,WA 95036 26. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, PMP-1 12. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE CONSTRUCTION INCLUDING CONCRETE EQUIPMENT PADS,FLASHING DETAILS,ETC. STRUCTURAL ENGINEER. WYE STAINER NTH CAPPED HOSE END BLOWUOWN VALVE TYPICAL EQUIPMENT DESIGNATION (PUMP) -{�- FLANGE -i F-- UNION POINT OF CONNECTION TO EXISTING THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND ABBREVIATIONS ECCENTRIC REDUCER PLUMBING,LLC ON A DESIGN BUILD WATER PIPING SYSTEMS CONCEPT.THEY ARE TO BE USED ONLY AAV AIR ADMITTANCE VALVE EA EACH HWS HOT WATER HEATING SUPPLY OC ON CENTER SHT SHEET STEAM TRAP WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION AC AIR CONDITIONING EAT ENTERING AIR TEMPERATURE HWR HOT WATER HEATING RETURN OSA OUTSIDE AIR SP STATIC PRESSURE WS WATER SERVICE CONTACT: CURTIS BOND. ABV ABOVE ECC ECCENTRIC IA INSTRUMENT AIR OAT OUTSIDE AIR TEMPERATURE SPEC SPECIFICATION HOSE BIBBS COLD WATER FILTERED AD ACCESS DOOR ECON ECONOMIZER ID INSIDE DIMENSION GA OUTSIDE AIR SQ SQUARE NO. DATE REWSION AFC ABOVE FINISHED CEILING EER ENERGY EFFICIENCY RATIO IE INVERT ELEVATION OD OUTSIDE DIMENSION SR SUPPLY REGISTER HOSE BIBB/WALL HYDRANT - COD WATER(ABOVE FLOOR/GRADE) AFF ABOVE FINISHED FLOOR EF EXHAUST FAN IH INSULATION HOT OPP OPPOSITE SS STAINLESS STEEL WATER(ABOVE FLOOR/GRADE) AEG ABOVE FINISHED GRADE EFF EFFICIENT,EFFICIENCY IN INCH,INCHES OV OUTLET VELOCITY SYS SYSTEM ��PIPE ANCHOR -- HOT HOT F TEMPERED WATER IF NOT AFUE ANNUALIZED FUEL EFFICIENCY EG EXHAUST GRILLE INFO INFORMATION OCP OVER CURRENT PROTECTION STAT THERMOSTAT ��ALLIGNMENT GUIDE INDICATED OTHERWISE) AHU AIR HANDLING UNIT EL ELEVATION INST INSTRUMENT OU OUTDOOR UNIT AL ALUMINUM ELEC ELECTRICAL INSUL INSULATE,INSULATION TEMP TEMPERATURE �TS TEMPERATURE/PRESSURE 140 HIGH TEMP HOT WATER 140' APPROX APPROXIMATELY EQUIP EQUIPMENT INV INVERT P PUMP TD TEMPERATURE DIFFERENTIAL TEST PORT/PETE'S PLUG OR AS INDICATED ARCH ARCHITECTURAL ET ELECTRIC TRACED IRR IRRIGATION(NON POTABLE) PD PRESSURE DROP TDH TOTAL DYNAMIC HEAD FLEXIBLE CONNECTION IN PIPING T TEMPERED WATER ATMOS ATMOSPHERE EXIST,(E)EXISTING IU INDOOR UNIT PERF PERFORATED TEMP TEMPORARY EXH EXHAUST PF PRE FILTER THRU THROUGH FUNNEL --- HOT WATER CIRCULATING BATT BATTERY E%T EXTERIOR JAN JANITOR PH PHASE TI TENANT IMPROVEMENT Y GOD BACK DRAFT DAMPER Pi PUSH ON JOINTS TSTAT THERMOSTAT NP NON POTABLE WATER BF BFC BEIND LOWFFINII FINISHED CEILING FD FIREGE F RENHEIT KW KILOWATT DAMPER OR FLOOR DRAIN KWH KILOWATT HOUR PNLS PANELS TYP TYPICAL TRU TERMINAL REHEAT UNIT VALVES WATER METER BHP BRAKE HORSE POWER FF FINISHED FLOOR LAT LEAVING AIR TEMPERATURE POC POINT OF CONNECTION XI>61WWWY HEAT TRACE FOR COLD WATER PIPE PARTNER IN CHARGE BI BACKWARD INCLINED FLGD FLANGED PRV PRESSURE REDUCING VALVE UL UNDERWRITER'S LABORATORY 0 BALANCING VALVE SB BLDG BUILDING FUR FLOOR LEIS POUND PS PIPE SUPPORT UNO UNLESS NOTED OTHERWISE PROJECT MANAGER BOD BOTTOM OF DUCT FCO FLOOR CLEAN OUT LC LOCKED CLOSED PSV PRESSURE SAFETY(RELIEF) UV UNIT VENTILATOR PRESSURE REGULATING VALVE DRAIN WASTE & VENT PIPING DJ BTU BRITISH THERMAL UNIT FPM FEET PER MINUTE LF LINEAL FEET VALVE I UNIFORM MECHANICAL CODE BTUH BRITISH THERMAL UNIT PER FLTR FILTER LOC LOCATION UP UNIFORM PLUMBING CODE �P WASTE(ABOVE FLOOR)PIPING PROJECT ENGINEER HOUR QTY QUANTITY PRESSURE REDUCING VALVE(PRV) BQ FOF FACE OF FLANGE LL LANDLORD UBC UNIFORM BUILDING CODE - FPI FINS PER INCH _VG LEAVING UPC UNIFORM PLUMBING CODE AUTOMATIC CONTROL VALVE-TWO WAY WASTE(BELOW FLOOR)PIPING PROJECT TEAM MEMBERS CFM CUBIC FEET PER MINUTE R RELIEF FSK FOIL SKRIM KRAFT LINED DUCT UG UNDERGROUND (ELECTRIC OPERATOR SHOWN) JM CHAR CHARACTERISTICS (SPUNSTRAND) MATL MATERIAL RA RETURN AIR ----------------VENT CHECK CHEM CHEMICAL INJECTION FT FEET,FOOT RED REDUCER BQ CHWS CHILLED WATER SUPPLY MA MED GAS V VOLT FU FIXTURE UNITS MA% MAXIMUM READ REQUIRED VAC VOLTS AC AUTOMATIC CONTROL VALVE-THREE WAY AW ACID WAS1E CHWR CHILLED WATER RETURN FV FACE VELOCITY MPG MEDIUM PRESSURE GAS RR REMOVE AND RELOCATE VDC VOLTS DC (ELECTRIC OPERATOR SHOWN) GW GREASE WASTE ENGINE! CLG CEILING FW FEED WATER RJ RESTRAINED JOINTS CO CLEAN OUT MA MIXED AIR VD VOLUME DAMPER BALL VALVE GD GARAGE DRAIN FPTU FAN POWERED TERMINAL UNIT MBH THOUSAND BRITISH THERMAL RET RETURN VAC VACUUM � CONC CONCRETE UNITS PER HOUR RG RETURN GRILLE C CONDENSATE DRAIN CONN CONNECT OR CONNECTION A VAV VARIABLE AIR VOLUME ��GATE VALVE G GAS MCC MOTOR CONTROL CENTER RPM REVOLUTIONS PER MINUTE VEL VELOCITY P PUMPED PIPING of 1LAsy CPLG COUPLING GALV GALVANIZED MCA MAXIMUM CIRCUIT AMPS RWL RAINWATER LEADER VF VENTILATION FAN GAS COCK CS CARBON STEEL GEN GENERATOR MAT MIXED AIR TEMPERATURE VFD VARIABLE FREQUENCY DRIVE ------0 FCO FLOOR CLEANOUT(FCO) - t CSC CARSEALED CLOSED GFl GROUND FAULT MAX MAXIMUM SS SANITARY SEWER VTR VENT THROUGH ROOF RELIEF VALVE WCO WALL CLEANOUT(WCO) " CSO CARSEALED OPEN CIRCUIT INTERRUPTER MECH MECHANICAL STAINLESS STEEL VOL VOLUME ���CHECK VALVE q CV CONSTANT VOLUME GR GRILLE MFR MANUFACTURER SA SUPPLY AIR �� ® FLOOR DRAIN ROOF 5T3fGW" CW COLD WATER GPM GALLONS PER MINUTE MED MEDIUM SCHED SCHEDULE V/PH/HZ VOLTS/PHASE/HERTZ r�BUTTERFLY VALVE TONAL�' CRD CEILING RADIATION DAMPER GV GATE VALVE MH MANHOLE SECT SECTION q� 0 FLOOR SINK 6/5/2023 GW GRAY WATER(NON POTABLE) MIN MINIMUM,MINUTE SEER SEASONAL ENERGY EFF.RATIO W/ WITH REDUCED PRESSURE BACKFLOW ASSEMBLY DET DETAIL MISC MISCELLANEOUS SVc SERVICE W/0 WITHOUT DFU DRAINAGE FIXTURE UNITS GWR GLYCOL WATER RETURN TITLE GINS GLYCOL WATER SUPPLY MV MED VACUM SHT SHEET W WASTE � BALANCING/MEASURING VALVE SHEET INDEX DIA DIAMETER SO SMOKE DETECTOR We WET BULB SHEET TITLE W PLUMBING COVER SHEET DIM DIMENSION HP HORSE POWER N NORTH,NEUTRAL SL SOUND LINING WC WATER CLOSET PO.01 PLUMBING COVER SHEET DISCH DISCHARGE HPFS HIGH POINT FINISHED SURFACE NA NOT APPLICABLE SV SOLENOID VALVE WCO WALL CLEAN OUT REFERENCE CODES PO.02 PLUMBING SCHEDULES DI DUCTILE IRON HR HOUR NC NORMALLY CLOSED SW SOCKET WELD WG WATER GAUGE P1.00 UNDERGROUND PLUMBING PLAN DMPR DAMPER NIC NOT IN CONTRACT STA STATION WHA WATER HAMMER ARRESTER IBC INTERNATIONAL BUILDING CODE-2018 P1.01 UNDERGROUND ENLARGED PLANS HTG HEATING WT WATER TANK IMC INTERNATIONAL MECHANICAL CODE-2018 P2.00 LEVEL 1 PLUMBING PLAN PROJECT ND. DN DOWN HT HEIGHT NO NUMBER OR NORMALLY OPEN STD STANDARD UPC UNIFORM PLUMBING CODE-2018 DP DIFFERENTIAL PRESSURE HVAC HEATING VENTILATION AND AIR NG NATURAL GAS SF SUPPLY FAN WT WEIGHT IFGC INTERNATIONAL FUEL GAS CODE-2018 P2.01 LEVEL 1 ENLARGED PLANS �y 2023-050 DR DRAIN CONDITIONING NTS NOT TO SCALE SFD SMOKE/FIRE DAMPER l W WATER IFC INTERNATIONAL FIRE CODE-2018 P3.00 PLUMBING DETAILS I'1r DATE DUNE 5,2023 DWG DRAWING HW HOT WATER S.I.O. NSTALLED BY NEC NATIONAL ELECTRICAL CODE-2017 P4.00 ISOMETRIC RISER DIAGRAMS W PROJECT NETWORK PATH HWC HOT WATER CIRCULATING 02 OXYGEN .I.O. OWNER/OTHER WSEC WASHINGTON STATE ENERGY CODE ADA AMERICAN DISABILITY ACT STANDARDS-2010 ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS- A17.1 -2007 W/2008 ADDENDA SAFETY CODE FOR REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER ELEVATORS AND ESCALATORS O O NFPA NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING 13D,13R,OR 13(AS APPLICABLE)-2016 HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„-t„ ■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. PLUMBING CALCULATIONS 2018 UNIFORM PLUMBING CODE PER TABLE 702.1 AND TABLE A-2.7 BUILDING SUMMARY MIN.SIZE DOMESTIC WATER SEWER DFU DOMESTIC WATER O TRAP/ARM PER HWPER PER TOTAL PER - HOT WATER P/PESIZINGTABLE COMMERCIAL ENERGY EFFICIENCY TABLE C404.3.1 FIXTURE TYPE IN. OTV FIXTURE TOTAL FIXTURE HW FIXTURE TOTAL WSFU BASED ON 2018 UPC CHART A2.1 DRINKING FOUNTAIN,WATER COOLER(ASSEMBLY) 1.25 1 0.75 0.75 -- - 1 1 PIPE MATERIAL TABLE C403.10.3 PIPING VOLUME & MAXIMUM FLOOR DRAIN-EMERGENCY 2 5 -- -- -- - 0 0 TYPE L COPPER LAVATORY,SINGLE 1.25 10 1 10 0.75 7.5 1 to MINIMUM PIPE INSULATION THICKNESS(in.)[a] PIPE LENGTHS FLUSH TANK SINKS -- -- -- -- -- -- - VELOCITY<=BFPS FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE(in.) SPECIAL PURPOSE 3 1 2 2 1.5 1.5 6 6 TEMPERATURE NOMINAL PIPE VOLUME MAXIMUM PIPING LENGTH(FT.) KITCHEN,DOMESTIC 2"DRAIN 1.5 1 1.5 1.5 1.125 1.125 2 z Psumo Fr a RANGE AND CONDUCTIVITY MEAN RATING <1 1 TO<11<2 1$TO<4 4 TO<8 x8 SIZE(IN.) (FLOZ.PER PUBLIC LAV OTHER SERVICE OR MOP BASIN-PUBLIC 2 OR 3 1 3 3 2.25 2.25 3 3 USAGE F h{ft�2F F b TEMPERATURE,f FOOT LENGTH URINALS WSFU RANGE MIN MAX ( ) Btu{in ) FAUCETS FIXTURES/APPLIANCES PRIVATE,1 GPF,FLUSHOMETER,.7s"SUPPLY 2 6 3 18 2 12 PIPE SIZE") 105-140 0.21 -0.28 100 1.0 1.0 1.5 1.5 1.5 1.5 2.0 43.D WATER CLOSETS 1 _ _ vz 0 4 40-60 0.21 -0.27 75 0.5 0.5 1.0 1.0 1.0 �" 3.0 0.5 21.0 1.6 GPF FLUSHOMETER VALVE,PUBLIC 3 11 5 55 -- - 4 44 3/4 4.5 11 <40 0.20-0.26 50 0.5 1.0 1.0 1.0 1.5 HV Engineering,Inc. TOTALS 36 90.25 12.375 78 1 12 22 1" $.Q 0.$ 13.D 11/4 23 So [a] FOR PIPING SMALLER THAN IY2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, 1Ya" 8.0 0.5 8.0 1 uz 51 100 REDUCTION OF THESE THICKNESSES SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN Consulting Engineers 2 101 265 FOOTNOTE[b]BUT NOT TO A THICKNESS LESS THAN 1 INCH. 112- 11.0 0.5 6.0 Hall Creek Office Park 2018 UPC APPENDIX A WATER SERVICE CALCULATIONS COPYRIGHT HV ENGINEERING b FOR INSULATION OUTSIDE THE SLATED CONDUCTIVITY RANGE,THE MINIMUM THICKNESS SHALL BE 2"AND LARGER 18.0 0.5 4.0 6912 220th St.SW,Suite 303 o ater aping to FV System(FV=Flush Valve,FT=Flush Tank) [] (� Mountlake Terrace,WA 98043 Hot Water Pi in to be Sized Based on a PIPE MATERIAL DETERMINED AS FOLLOWS: P 9 FT System(FV=Flush Valve,FT Flush Tank) PIPE MAINS FIX UNIT GPM SIZE TYPE L COPPER �" Phone:(206)e0e6-9669 COLD WATER 90 64 SEE PLANS FLUSH TANK T=rl(1 +t/r)"(KA)-1) -.hvengin ring.biz HOT WATER 12 8 SEE PLANS VELOCITY<-5 FPS WHERE: T=MINIMUM INSULATION THICKNESS BLDG SUPPLY PRESSURE(PSI): 72.0 PS0100 FT 8 r=ACTUAL OUTSIDE RADIUS OF PIPE PIPE LOSS BETWEEN BUILDING AND TENANT SPACE(PSI): 22.0 AVERAGE 4 PSI/1W AT 530 FEET WSFU RANGE MIN MAX t=INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE Project SUPPLY PRESSURE FOR PIPE SIZING TENANT(PSI): 50.0 PIPE SIZE" K=CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE ] 112 0 4 APPLICABLE FLUID TEMPERATURE(Btu•in/h•ft"2•F) TENANT IMPROVEMENT: COLD WATER PRESSURE LOSS: 3/4 4.5 9 k=THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID PROCESS SOLUTIONS ELEVATION CHANGE(PSI) 4.3 10 FEET AT 0.433 PSI/FT 1 10 16 TEMPERATURE. MIN.RESIDUAL PRESS.AT REMOTE FIXT.(PSI) 30.0 (TYPICALLY PROVIDE 25 PSIG-5 PSIG FOR TXV) 1 1/4 17 16 [c] FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING,REDUCTION OF THESE THICKNESSES BY 1Y22 TOTAL PRESSURE LOSS: 34.3 COPYRIGHT HV ENGINEERING INCHES(38mm)SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE[b]BUT Location 78.0 PIPE MATERIAL NOT TO THICKNESSES LESS THAN 1 INCH(25mm)). 34.3 TYPE L COPPER Ave NE, AVAILABLE PRESSURE(PSI) 43.7 FLUSH VALVE 7 St VELOCITY<.BFPS Industrial Parkk,, Building B LONGEST PIPE RUN WITHIN TI(FT) 100.0 43.67 X 100 FT Arlington,WA 98223 X 1.25(FITTINGS) 1.25 125.0 125 FT PSY100 FT 8 WSFU RANGE MIN MAX Prepared For Friction Loss Not to Exceed 34.9 PSI/1 DOFF LOSS PIPE SIZE(") ELECTRIC WATER HEATER SCHEDULE PUMPS Size All Piping Based on a Friction loss of.®PSIADOFF LOSS 1 0 3.25 Bond Plumbing, LLC and max velocity based on installation standard. 1 114 4.25 12 MARK NUMBER CP-1 CP-2 1112 13 35 EQUIPMENT NUMBER WH-1 Ill SERVICE DESIGN MAX FT 2 36 135 LOCATION JAN 130 ADJACENT TO RESTROOM 160 SIZE MAINS AND RISERS PER BELOW PSIMOOFT LOSS PER APPL. 21/2 136 345 UNIT LOCATION JANITOR 130 ADJACENT TO RESTROOM 110 JAREA 19023 36th Ave W.Suite G MAIN%LENGTH OF TOTAL PIPE 90% 8 113 COPYRIGHT HV ENGINEERING RISERS/UNIT PIPING LENGTH OF TOTAL PIPE 10% 8 13 SYSTEM 120 DEG 120 DEG Lynnwood,WA 98036 TOTAL ALLOWABLE PSIG FRICTION LOSS 43.7 SYSTEM SERVED DOMESTIC HOT WATER DOMESTIC HOT WATER DOMESTIC DOMESTIC ACTUAL TOTAL FRICTION LOSS 10.0 TYPE CARTRIDGE CARTRIDGE SAFETY FACTOR PSIG,MUST BE POSITIVE NUMBER) 33.7 TYPE TANK HEATER TANK HEATER SERVICE CONDITIONS NOTE,CALCS CONSERVATIVE BECAUSE NO CREDIT IS TAKEN CAPACITY-GPM 2 2 FOR LOWER THAN MAX FLOW RATES IN EACH PIPE SECTION, CAPACITY-GALLONS 50 50 TOTAL HEAD-FT 15 15 RECOVERY(GPH @ 90 DEG RISE 27 27 FLUID WATER WATER THESE DRAWINGS WERE DEVELOPED SERVICE CONDITIONS TEMPERATURE-DEG F 140 DEG F 140 DEG F FOR EXCLUSIVE USE BY BOND LVG WATER TEMP-DEG F 140 140 UNIT CONDITIONS PLUMBING,LLC ON A DESIGN BUILD ENERGY FACTOR SPEED-RPM 3250 3250 CONCEPT.THEY ARE TO BE USED ONLY PLUMBING FIXTURE SCHEDULE ELECTRICAL CONNECTIONS INLET/OUTLET 3/4"SWEAT 3/4"SWEAT WITH WRITTEN PERMISSION OF BOND NUMBER OF STAGES 1 1 MOTOR PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. SYMBOL ITEM WASTE VENT CW HW SPECIFICATION REMARKS KW INPUT/STAGE 4.5 4.5 ENCLOSURE TYPE WC-1 WATER CLOSET-FLUSH VALVE 3 2 1 - SEE CONTRACTOR'S SUBMITTALS 1.28 GPF TOTAL KW 5.0 5.0 HORSEPOWER-MINIMUM t/25 1125 NO. DATE REVISION FLOOR MOUNTED VOLTS-PHASE-HERTZ 240/1/60 240/1/60 SPEED-RPM 3250 3250 WCAA WATER CLOSET-FLUSH VALVE(ADA) 3 2 1 - SEE CONTRACTOR'S SUBMITTALS 1.28 GPF NOTES [11,[21,[31 [11,[21,[31 VOLT.-PHASE-HERTZ 115/60/1 115/60/1 FLOOR MOUNTED MANUFACTURER-DESIGN BASIS MANUFACTURER-DESIGN BASIS TACO 008-BRONZE TACO 008-BRONZE UR-1 URINAL 2 1-1/2 314 - SEE CONTRACTOR'S SUBMITTALS 1.0 GPF MAKE RHEEM RHEEM NOTES [11 [i] MODEL PRESTIGE PR050 PRESTIGE PRO50 REMARKS UR-1A URINAL(ADA) 2 1-12 3l4 - SEE CONTRACTOR'S SUBMITTALS 1.0 GPF SIZE EIGHT FULL/DIAMETERMEIGHT 592#/22-1/4"/61-3/4" 592#/22-1/4"/61-3/4" (1]PRO VIDETIMERIAOUASTAT REMARKS 6/5/2023 [11 MOUNT ON R-10 INSULATED PAD. L-IA LAVATORY(ADA) 1-1/2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM [21 PROVIDE SEISMIC STRAPS. COUNTER MOUNTED [31 WEIGHT=OPERATING WEIGHT L-2A LAVATORY(ADA) 1-112 1-W 112 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM WALL HUNG 6/5/2023 8-1 BREAK ROOM SINK 2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM PARTNER IN CHARGE S-2 UTILITY SINK 2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM EXPANSION TANKS SB PROJECT MANAGER DF-1A DRINKING FOUNTAIN 1-1/2 1-1/2 112 - SEE CONTRACTOR'S SUBMITTALS EQUIPMENT NUMBER ET-1 ET-2 DJ DUAL HEIGHT(ADA) I I I I I PROJECT ENGINEER MS-1 MOP SINK 3 2" 112 112 SEE CONTRACTOR'S SUBMITTALS SERVICE BQ LOCATION JAN 130 ADJACENT TO RESTROOM 116 PROJECT TEAM MEMBERS SYSTEM DOMESTIC HW DOMESTICHV/ JM 6/5/2023 NOTE 1-COORDINATE FINAL FIXTURE SELECTION WITH OWNER PRIOR TO PROCUREMENT TYPE ORIENTATION VERTICAL VERTICAL CHECK LINING YES YES BQ MISCELLANEOUS PLUMBING EQUIPMENT SCHEDULE JASME NO NO SERVICE CONDITIONS ENGINEERS SEAL ID DESCRIPTION MAKEIMODEL CERTIFICATIONS REMARKS CAPACITY-GALLONS 6.4 6.4 FD-1(E) FLOOR DRAIN(FD) SEE CONTRACTOR'S SUBMITTALS MEDIUM DUTY.8-1/2"ROUND CAST IRON GRATE.PIPE SIZE PER PLAN. ACCEPTANCE-GALLONS 3.2 3.2 EMERGENCY ONLY INSULATION NA NA A� FLUID WATER WATER OF ASy FCO FLOOR CLEANOUT SEE CONTRACTOR'S SUBMITTALS PRESSURE-PSI 150 150 TEMPERATURE-DEGF 140 140 TMV-1 MIXING VALVE SEE CONTRACTOR'S SUBMITTALS ABBE 1017 AT WATER HEATER UNIT CONDITIONS INLET&OUTLET TAP SIZE 3/4" 3/4" 5" TMV-2 MIXING VALVE SEE CONTRACTOR'S SUBMITTALS ABBE 1070 POINT OF USE AT LAVS WEIGHT FULL 26 26 DIAMETER AND HEIGHT 12"x1T 12"x18" MANUFACTURER-DESIGN BASIS AMTROL ST-12C AMTROL ST-12C 6/5/2023 TP-1 TRAP PRIMER SEE CONTRACTOR'S SUBMITTALS PRESSURE ACTIVATED REMARKS � 6512023 6/5/2023 w nTLPLUMBING SCHEDULES PIPING SYSTEM AND SPECIFICATION SCHEDULE v) SYSTEM LOCATION MATERIAL JOINT METHOD REMARKS PIPE INSULATION - WASTE&VENT BELOW GROUND SCH.40 PVC(SOLID CORE) SOLVENT WELD PROJECT 10. DOMESTIC WATER BELOW GROUND COPPER TYPE K BRAZE 2023-050 DOMESTIC WATER BELOW GROUND PFX EXPANSION COUPLING DATE JUNE 5,2023 WASTE&VENT ABOVEGROUND PVC-SCHEDULE 40 SOLVENT WELD W PROJECT NETWORK PATH DOMESTIC WATER 2"&SMALLER ABOVE GROUND COPPER TYPE L SOLDER OR PROPRESS INSULATE PER WSEC NOTES: 1.RECIRC LOOP MUST BE INSULATED PER ESDS AND WASHINGTON STATE ENERGY CODE,WHICHEVER IS GREATER. REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ;H O.O L A THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. 42> '92 13 14 5 6 17 �q O zI I I IA 4"RL u4 6' L UP_ 6"RL C� �.E,..�....................... Y4"CW UP TO O. ...................... "C UP TO >K--111 zi 114 1' ED o o HV Engineering,Inc. C.EI Engineers -—-—-—-—---Ill .................. -—-—--ELL :� Hall Creek OfficePark M IL 61 STRIP- 4"W UP — 6912 220th St.SVV,Suite 303 UfF T��C�40UT FOR Mountlake Terrace,WA 98043 FUT =L7 POUR 6"WCM Phone:(206)706-9669 ­hVergIneenng.biz BELOJIFINISHED FLOOR. FCb FCO FCO F ------------------------t-------- 0 FCO ®COFCO ... ........................... -------- -T--------r -------- -- FCC ------------------- -3- 4 Project L— L TENANT IMPROVEMENT: PROCESS SOLUTIONS 2N 1: MANUFACTURING Location 17216 51 st Ave NE, FT7 F7 Industrial Park,Building B Arlington,WA 98223 II Ll — — — — — — — Prepared For Ell I-J--i C Bond Plumbing, LLC DEMISING AALLS TO INCLUDE 19023 36th Ave W.Suite G II I Lynnwood,WA 98036 3/4"�S'B'WAINRCOT T F F- THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND FCO FC0 CO 6 F PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS.BOND.T, NO. DATE REMSION WAREHOUSE —1 VA91% �--6"W@1% III PoORWER A DATA DROP WORK STATIONS. �/,"CW UP TO "CW UP TO HB-1 6 W@ �6 1 6 LE.- 4+/ @% 6"W@1% S13 :�7PARTNER IN CHARGE 1 6"WO17 LF.- 4"+/- -1 E-84"+/- PROJECT MANAGER BELOW WISHED FLOOR BELOW FINISHED FLOOR B W FINISHED FLOOR DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS im CHECK -TD Bo o ENGINEERS SEAL A. 100 (1�2 13 14 5 6 7 18 of 5 6/5/2023 UNDERGROUND PLUMBING PLAN EASTERN END I SCALE: 1'-0" ITUE 0 W UNDERGROUND PLUMBING PLAN PROJECT NO. 2023-050 DATE JUNE 5,2023 W PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHEET—NumBER BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF TV ENGINEERING,INC.AND IS NOT TO BE 0" P1 .00 USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC ACCORDINGLY. HV Engineering,Inc. a"w Poc To(L)6"w Consulting Engineers Hall Creek Office Park 6912 220th St.SW,Suite 303 Mountlake Terrace,WA 98043 E Phone:(206)706-9669 www.hvengineering.biz 2"W UP(1 DFU) r I UTILITY 4"W POC TO(E)6"W 13, 2"W UP Project JANITOR STORAGE I W/CD 30 J 3"W UP I DFU) (2 DFU) TENANT IMPROVEMENT: PROCESS SOLUTIONS 7�2"V UP I I w/CD [] I Location (3 DFU) I I I Industrial ParkeBuilding B UP TO ----------8 DFU) 2"W UP TO WOMEN 1 f2"W(3 D I j I Arlington,WA 98223 r F DFU) 32 ! I II Prepared or --- ( Pea dF P(0 DF W( DFU) I Bond Plumbing, LLC W(35 EIF_U)- NP Till I ' z ) I ', - - _ ------- - ----- -- -- ----- -- - -- - -_-_ 4--=D________-- ---------- BREAK A9S036 DFU "W(51 DFU) I ;" t Ave Suite Lynnwood,W 4 (48 DFU) '�2"W UP(1 DFU) 3"W UP TO WCO W (47 DFU) 2'V UP(8 DFU) ! 4"W-41_DFU 2°W UP(2 DFU) (4 TYP.)I --( ) 4"W UP TO FCO I ,________ I 3•14(9 DFU) THESE DRAWINGS WERE DEVELOPED MEN W( DFU) 4"W(23 DFU),\ FOR EXCLUSIVE USE BY BOND .'I ' ----{ PLUMBING,LLC ON A DESIGN BUILD -____-_ FD(O DFU) I 133 2"W UP 4"W(21 DFU)\ 7 i,�ii i� )-----_' ----- --X}----3�WJ DFU) CONCEPT_THEY ARE TO BE USED ONLY 3I 1 OFU 2"W UP TO W/CO 3 W(21 DFU) . 3°W DN W UP(4 DFU) WITH WRITTEN PERMISSION OF BOND tf PLUMBING,LLC. FOR INFORMATION I I (2 DFU) CONTACT: CURTIS BOND. oo— TT I ( 3"W UP --_-)' NO. DATE RENSION 2'V UP f ( ) YW UP j 4 2" 2 DFu ! (erveWD�Ez (a DFu) L ET ❑ ❑� J W/COP ---- 2"W UP T Ell I - -- (0 DFU 2"W UP (6 DFU) ---------- W/CO FD(0 DFU - ------- ----- -- -- W UP W CO (2 DFU) I (2 DFU) 2"W UP TO 2"W UP TO FD(0 DFU) FD(O DFU) I PARTNER IN CHARGE SB PROJECT MANAGER DJ ENLARGED PLUMBING PLAN - UNDERGROUND ENLARGED PLUMBING PLAN - UNDERGROUND PROJE BQCT ENGINEER OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS PROJECT TEAM MEMBERS JM SCALE: J4°=1'-0" P1.01 SCALE: J4"=V-O" CHECK BQ ❑ ❑ I■ ENGINEERS SEAL A. OF WASy 2 5� TONAL�'� 6/5/2023 LL1 nnUNDERGROUND ENLARGED PLANS G PROJECT N0. 2023-050 DATE w JUNE 5,2023 /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHET NUMBER BAR MEASURES ONE INCH p 1 01 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„-t„ ■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. Ito p 4 RL,OL U TO RO F DRAT IS 6890 S. . 4"COMBINED RL DN COME N "COMB 4"COMBINED RL ON (3040S.F.) 4' 9400 .F.) (9400 .F.) 6" OMBINED RL ON 1 (6890 S.F.) (i HB � (940 S.F.) _ O RD 1 RD RD RD 1 CW ON �>"—` 1 1 ,° -Y4"CW DIN 1 HV Engineering,Inc. °w �°/" OD ODo- Consulting Engineers 4"RL,OL U � 1 4"RL,OL UP TO J/ 1 1 4'RL,OL UP TO Hall Creek Office Park INS ROOF DRAINS 1y2"CW FUTURE TENANT STUB ROOF DRAINS 6912220th St Sw,Suite 303 9400 S.F.) - (9400 S.F.) PROVIDE BALL VALVE�\ (9400 S.F.) 1Y2"CW FUTURE TENANT STIR Mountlake Terrace,WA 98043 \\\\ PROVIDE BALL VALVE n n n—. .—.—.—.—. .—. .—.—.—. — Phone:(206)706-9669 Mhvengineerng.bi z 2J'2'CW 2"CW —.—.—.iJni.—.—. w-3VTR o�3VTR W 3' R 3"VTR—'O 3"VTR 3 VTR 1YJz"CW FUTURE TENANT STUB ° o p 1J�"CW FUTURE TENANT STU I I Project PROVIDE BALL VALVE o I PROVIDE BALL VALVE J q TENANT IMPROVEMENT: PROCESS SOLUTIONS P201 MANUFACTURING Ol ao I Location I I 17216 51 st Ave NE, Industrial Park,Building B — — — — J Arlington,WA 98223 Prepared For TM �7FM Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. NO. DATE RENSION WAREHOUSE 141 r --------------------- I "CW ED "CW ON PARTNER IN CHARGE SB PROJECT MANAGER DJ PROJECT ENGINEER RWNSPCI.- BQ T(ILS,T PROJECT TEAM MEMBERS D I D CHECK BQ S S Z Z ENGINEERS SEAL FT T IT A. OF WASy 2 TONAL'I'�� T� 6/5/2023 LEVEL 1 PLUMBING PLAN - EASTERN END SCALE: J(e"=1'-0" LU nnLEVEL 1 PLUMBING PLAN G PROJECT N0. 2023-050 DATE JUNE 5,2023 w /'� PROJECT NETWORK PATH a— REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ;H P2.00 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. - �1�'CW POC TO(E)1}¢'CW / 2"CW POC TO(E)2"CW HV Engineering,Inc. I Consulting EnOlneers Hall Creek Office Park 6912 220th St.SW,Suite 303 f _ Mountlake Terrace,WA 98043 E $ ET CP 3.00 2'CW(64.$WSFU) I Phone:(206)706-9669 —h—gineering.biz I I I I �4'HW(8.625 Ill UTILITY 131 3"V POC TO(E)3'VTR I Project JANITOR STORAGE 13p I i TENANT IMPROVEMENT: f i *'HWC 2 DA I PROCESS SOLUTIONS }¢"CW(2.5 WSFU) •HW(6.375 WSFU) i 3"V POC TO(E)3"VIR Location I � LJ LJ 1 2"Cw I (5s.s WSFU)I _ _ _ 17216 51 st Ave NE, --- --- -- I WV(3 DFU) I Industrial Park,Building B rr Arlington,WA 98223 ------- ----------------+---1 3• 0 �) I j 1}�°CW(31.5 WSFU) i)FV(3 2- (32 DFU j I 1} DFU) Q - ---- -- --1- --------------------------------------' Prepared For 2� DFU) -- - 24 — ------ ----- "V(51 DFU) ; ! Bond Plumbing, LLC 2"CW 1A -- LAY: 1A I f (57.25 WSFU) -r ( `--, ------ ----- - I _ - I 3"V 48 DFU I Wl 3.375.-` ;-- _ ---------------- -I -----1 ( ) i 19023 36th Ave W.Suite G - I --------I I - - I - r---- ----- -- •HW 1.125 WSFU I ', 2/V 1}¢"CW(30.37 )(21 DFU) ` Lynnwood,WA 95036 u b__ u - b b b bu u H�, R z cw s. ) .W 9 z'v(z3 Fu) h"CW(29.25 WSFU ' ` t1 251) i 2"V(11 DFU) 2"V(9 DFU)) e e 1A - MEN 1A 1 H j 4"FCO �_____________________________ __ __ _ ��e__-_�__--_-__� •__`_r_ --- THESE DRAWINGS WERE DEVELOPED I *"HW(4.875 ) T FOR EXCLUSIVE USE BY BOND 1A 1 1 1 133 " i __________ r 1 - 13'7;WSFU) PLUMBING,LLC ON A DESIGN BUILD CW(3,45 3' _ -___.——_; i r I 2"V(5 DFU) CONCEPT.THEY ARE TO BE USED ONLY )�" ( WI I ---„, TI 1 CW WITH WRITTEN PERMISSION OF BOND --------y--I- -- PLUMBING,LLC. FOR INFORMATION 1WCW(12 WSFU) 'y'"CW(5.25 N5�U) � I I I (5.75 WSFU) CONTACT: CURTIS BOND. A NO. DATE RENSION UR UR 1A P3.00 2 2 2 O NISEX Y2"H CFO}�1•--' -----'UNISEX 1WV(6 DFU) z'v po DFu) r r ___,;- �n�®''� 1 $J FD 1)FCW(25.2 -- - --- -- I x-CW(11. ) 0 � IWV 2 U - I WCW(1.5 WSFU) I )FHW(0.75 WSFU) PARTNER IN CHARGE SB PROJECT MANAGER DJ ENLARGED PLUMBING PLAN - 1ST FLOOR ENLARGED PLUMBING PLAN - 1ST FLOOR PROJE BQCT ENGINEER OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS PROJECT TEAM MEMBERS SCALE: J4"=1'-0" P2.01 SCALE: J4"=1'-0" JMCHECK BQ ❑ ❑ I■ ENGINEERS SEAL A. OF WASy 2 5� 6/5/2023 UJ nnLEVEL 1 U) ENLARGED PLANS G PROJECT N0. 2023-050 DATE JUNE 5,2023 W /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHET NUMBER BAR MEASURES ONE INCH ^ O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„—t„ L■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. MAX 1)FCW PIPE )F BRANCH ADJUSTABLE STRAINER NON—SHRINK GROUT \_ _ _ — YF BALL ACCESS DOOR(AT RECESSED F— UNION TYP. FINISH LOCATION IN FINISHED SPACES) OFFSET HOT WATER MAIN TO HAND DEPRESS DRAIN 1/4" TO 1/2" FLOOR I I PPP P2-500 O WHERE NOT ALREADY SLOPED I PRIME RITE TRAP SINK/LAVATORY AS NEEDED. PRIMER VALVE / Y/ MANUFACTURER'S THERMOSTATIC DISTRIBUTION UNIT TEMPERING VALVE DHERE APPLICABLE f DRAIN AFFOR EVERY WHERE APPLICABLE CLAMPING RING 20'OF PRIME LINE I I NOTE: ROUTE HOT WATER PIPING MAIN }fit"COPPER TO FLOOR OVER TO LAVATORY SUCH THAT NO MORE DRAIN,TRAP MAKE UP THAN 2'OF"DEAD"BRANCH PIPE EXISTS. WATER(TYP.)QTY.AS TYPICAL FOR ALL AND LAVATORIES. REQUIRED(MAX 2) HV Engineering,Inc. PROVIDE TRAP PROVIDE WATERPROOF TYPICAL LAVATORY PRIMER MEMBRANE AT ALL FLOOR Consulting Engineers DRAINS, FLOOR SINKS, AND L — — — — J Hall Creek Office Park TRENCH DRAINS. 6912 220th St.Sw,suite 303 Mountlake Terrace,WA 98043 DRAIN PIPE n FLOOR DRAIN DETAIL n TRAP PRIMER DETAIL n TYPICAL LAVATORY PIPING DETAIL Phone:(206)706-9669 www.hvegineering.biz P3.00 SCALE: NTS P3.00 SCALE: NTS P3.00 SCALE: NTS Project TENANTIMPROVEMENT: PROCESS SOLUTIONS Location 17216 51 st Ave NE, Industrial Park,Building B GATE VALVE(TYPICAL) Arlington,WA 98223 UNION(TYPICAL) CIRCULATING PUMP Prepared For CHECK VALVE(TYPICAL) � CE (TYPICAL)VALVE �" Bond Plumbing, LLC "HW 19023 36th Ave W.Suite G (2 GPM) Lynnwood,WA 96036 EXPANSION CW/HW/HWC WITHIN 15' TANK OF WATER HEATER TO BE COPPER(TYP.) 140 140 SIZE PER PLANS t INSTALL PER I " E2 THESE DRAWINGS WERE DEVELOPED MANUFACTURER'S TV SIZE PER PLANS FOR EXCLUSIVE USE BY BOND INSTALL PER PDI 1 PLUMBING,LLC ON A DESIGN BUILD STANDARDS AND REQUIREMENTS CONCEPT.THEY ARE TO BE USED ONLY MANUFACTURER'S HOT OR COLD WATER SUPPLY IF BRANCH IS GREATER THAN 20' SIZE PER WITH WRITTEN PERMISSION OF BOND INSTRUCTIONS LONG,PROVIDE ANOTHER WHA IN PLANS MIDDLE,EACH SIZED FOR HALF PLUMBING,LLC. FOR INFORMATION THE SIZE PER PLAN FIXTURE UNITS CONTACT: CURTIS BOND. PDI THERMOMETER — SIZE IF HORIZONTAL BRANCH IS LESS No. DATE REVISION f THAN LONG,PROVIDE ONE YMA AT END OF LINE RELIEF VALVE,PRESSURE AND r? x TEMPERATURE.PIPE DRAIN FULL PDI SINGLE FIXTURE MULTIPLE FIXTURES SIZE TO MOP SINK BELOW STRAP WATER HEATER SIZE u TANK TO WALL FOR SEISMIC RESTRAINT.TWO PC TO PROVIDE WATER HAMMER PLACES. PIPE FIXTURE FIXTURE UNIT TABULATION ARRESTERS BY SIOUX CHIEF, SZE UNIT LOAC FIXTURE COLD HOT PRECISION PLUMBING PRODUCTS, A )2" 1-3 WATER CLOSET g __ WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0—RING CONSTRUCTION, B 1" 4-12 LAVATORY/HAND SINK 1 1 HAVING PDI#WM-201,ASSE#1010 1,2 AND ANSI#A712.26.1M CERTIFICATION. C 1" 13-25 KITCHEN SINKS 1.5 1.5 INSTALL IN HORIZONTAL OR VERTICAL D 1Y" 26-50 MOP BASIN 3 3 POSITION,BUT NEVER UPSIDE DOWN. DRAIN VALVE,TYP. INSTALL IN LINE NTH WATER FLOW PARTNER IN CHARGE RAIN TO I E 1)¢" 51-85 URINAL 5 -- UNITSTIAS SHOWN ON IF SON THESDRAWINGS APPROVED IZE THE W.H.DLOCATION R10 INSULATION UNDER SB AND/OR PER THE TABLES SHOWN FLOOR/PLATFORM TANK PER CODE PROJECT MANAGER ABOVE. DJ DRAIN PAN PROJECT ENGINEER n WATER HAMMER ARRESTERS n WATER HEATER DETAIL BQ PROJECT TEAM MEMBERS P3.00 SCALE: NTS P3.00 SCALE: NTS JM CHECK BQ ENGINEERS SEAL A. pF WASy 2 5� ZONAL�'� 6/5/2023 LL1 nnISOMETRIC RISER DIAGRAMS G PROJECT N0. 2023-050 DATE JUNE 5,2023 W /'� PROJECT NETWORK PATH 0— REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES INC. A.O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING P3.00 r HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. �4"W POC TO(E)4"W 2"V POC TO(E)3"V�� ^ \ \ \ �2"V(5 DFU) 1)h•V(3 DFU)-' y ��„% 3•V(51 DFU) I I \ DF I IN, I \ ; 1A T'T2"V(4 DFU) 2"V(9 DFU) I I I 3°V(48 DFU j �//�2•W(1 DFU) // /� -2"W(3 DFU) / 2"V(11 DFu,`\ ��' WC HV Engineering,Inc. Consulting Engineers �Y 2'V 10 DFU `�' \ � / 1z ( ) I I I I Hall Creek Office Perk 2"V 21 DFU I j.� ,}¢"V($DFU \ i j (51 DFU) ( I2°t/(1D DFU) I I 1� I 6912220th St.SW,Suite 303 3°V 45 DFU)/ 4"W POC TO(E)4"W 3"W(9 DFU) j UR j e j Mountlake Terrace,WA 98043 ( ) ( ```` i 3"W(9 DFU i 1 A i // \ A Phone:(206)706-9669 2"V 3 DFU 3°V(39 DFU I \�� L / I —.homer,ineerin `�/ \ �� �•�,-2"V(10 DFU) R I I/ FD ,...,.2"W(5 DFU) \ g g.biz 1)67V(7 DFU \ i 1A \ /fG^ \ �`�� i i 1A 3"V(32 DFU}\T�?, ��`\ ``i I L / 2"V POC TO(E)3"VJ ` \�'' r/� `�i�`� /� 2•W 1 DFU r� 2"V(24 DFU i f I 1A\ ` 1 1A/ \ ``` ` \ I S I I i .\ \ i ( ) Project I`\� Tv/ \ i I i I /`�• 4"W(48 DFU) 2"v(23 DFU)-� \ i �/ i TENANT IMPROVEMENT: 2'V(8 DFU) I I L �`�i 4"W(23 DFU) \I I I \2-W(0 DFU)/iPROCESS SOLUTIONS ( �: I '' 1A�' i 4"W 21 DFU I\ / i 1)h"V(2 DFU) 2-V 8 DFU I I e I ( )- / e � /, I ; Location we i \ 1 `I)TV(6 DFU) I �n y / FD i I i e i i `4 I Ms i 1 i i I w 41 DFU) �, / \ ; we 17216 51 st Ave NE, /�•W(35 DFU) % I Ij/ // I 1A , AIndustria nl,WA 98223ng B \\ 2"W(0 DFU}e\ I /1c 2 w(s DFu)J r '\;\1A I \I iD 1A \ JJI Prepared For \ 1n 3"W(10 DFU) 3"W(10 DFU) A�. Bond Plumbing, LLC \ I / 4"W(11 DFU) 3"W(3 DFU \ �l2"W(0 DFU) UR i �/ 2 W(2 DFU) e23 36th Ave W.Su yV Lyn 8 3 // nnwood,WA 6ite G `4-W(11 DFU)` 3"WCO RISER DIAGRAM - 1ST FLOOR RISER DIAGRAM - 1ST FLOOR THESE DRAWINGS WERE DEVELOPED MEWS AND WOMEN'S RESTROOMS 2 MEN'S AND WOMEN'S RESTROOMS FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD P4.00 SCALE: NONE P4.00 SCALE: NONE CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. 2"CW POC TO (E)2°CW ^CW HWC N0. OATS RENSION POC TO(E)1}h° 2 CW(64.5 WSFU) I CW(31.5 WSFU) HWC II / Y4"HW(8.625 WSFU) "CW(2.5 WSFU °HW(1.125 WSFU) ,)h^CW(30.375 WSFU) / 19-CW(5.75 WSFU. \ / 1 •CW(11.5 WSFU. DF / 1)h"CW(13.75 WSFU) I \ S CW �4"HW(6.375 WSFU) /'/' HW(4.875 WSFU) `\ \�`` )¢"CW(3.75 WSFU }h•HW(3.375 WSFU) �4°HW(3.375 WSFU 3 CW � PARTNER IN CHARGE "HW 1A PROJECT MANAGER ' (1.5 WSFU) UR�' SB (2.25 WSFU) ` 1T )¢"HWC(1 GPM) 1)T CW(29.25 WSFU) 1q 2A e DJ CP '"CW(5.25 WSFU %°CV1 3.00 PROJECT ENGINEER 1 1)h"CW(15.25 WSFU) L ee3 BQ MS L 1A e 1A 3.00 1}h"CW \/ }h"HW(0.75 WSFU) PROJECT TEAM MEMBERS (25.25 WSFU) WC JM ffil 2"CW(59.5 WSFU 1A 1A 1A to I WC 1A CHECK 2"CW(57.25 WSFU WC 1A 1A BQI%-CW(2 WSFU) a ENGINE! 2"CW(45.25 WSFU) I WC I WC 1 1Jq•CW(2 WSFU) 2A WA WC '� 1A OF WAsy 1A UR 1A 5� UR 1 UR 1 6/5/2023 W nnISOMETRIC RISER DIAGRAM - 1ST FLOOR RISER DIAGRAM - 1ST FLOOR 0 RISER DIAGRAMS OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS _ P4.00 SCALE: NONE P4.00 SCALE: NONE ` PROJECT N0. G 2023-050 Q[ DATE JUNE 5,2023 W PROJECT NETWORK PATH /'� LL REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ; P4.00 H w .O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO BE U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. GENERAL PLUMBING NOTES PLUMBING LEGEND PLUMBING LEGEND 1. THE FOLLOWING NOTES APPLY TO ALL PLUMBING DRAWINGS. ADDITIONAL PLUMBING 13. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS 27. PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM SYMBOL DESCRIPTION SYMBOL DESCRIPTION NOTES MAY BE INDICATED ON EACH PLUMBING DRAWING. SEE SPECIFICATIONS FOR OF PLUMBING EQUIPMENT(VOLTAGES,ETC.). PIPE SECTIONS. ADDITIONAL REQUIREMENTS. PIPING GENERAL 14. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY 28. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT HOW PIPING OFFSETS 2. INSTALLATION SHALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS WHICH MAY BE REWIRED. (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, _-I>_ ROW ARROW rlLs CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFUCT SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 26 29. PATCH ALL FLOOR, WALL, CEILING AND ROOF OPENINGS CREATED/CAUSED BY THE K NORTH NORTH ARROW SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL ELECTRICAL PRIOR TO INSTALLATION OF EQUIPMENT AS REWIRED TO PROPERLY DEMOLITION OF EXISTING PIPES, FIXTURES, ETC. IN ACCOR ANCE WITH DIVISION 1 I, CAP OR CLEANOUT TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH SERVE EQUIPMENT. OF THE SPECIFICATIONS. CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. C, PIPE UP OR TEE UP AND DOWN 15. SECURE WATER HEATERS AND STORAGE TANKS AND PLUMBING EQUIPMENT TO 30. ALL WATER PIPING IN UNHEATED SPACES EXCEPT CIRCULAIED HOT WATER SHALL SECTION IDENTIFICATION 3. INSTALL ALL WASTE LINE CLEANOUTS IN ACCORDANCE WITH CHAPTER SEVEN OF STRUCTURE AS REQUIRED BY CODE. REFER TO THE STRUCTURAL DRAWINGS FOR BE HEAT TRACED AND INSULATED. C PIPE DOWN A THE UNIFORM PLUMBING CODE: ADDITIONAL SPECIAL REQUIREMENTS RELATED TO THE PLUMBING INSTALLATION. M201 A.3"WASTE PIPE-3"CLEANOUT WITH 2.5'PLUG 31. WHERE PIPE SIZES ARE NOT SHOWN ON DRAWINGS, SIZE PI ING PER THE UNIFORM Q PIPE TEE UP B.4'WASTE PIPE-4'CLEANOUT WITH 3.5'PLUG 16. PROVIDE PLUMBING ANCHORAGE AND EXPANSION EVERY 1DO' PIPE LENGTH PER PLUMBING CODE. C.6'WASTE PIPE-4'CLEANOUT WITH 3.5'PLUG CODE. PIPE TEE DOWN SHEET IDENTIFICATION 32. PRIOR TO SUBMITTING ALL PLUMBING FIXTURES THE CONTRACTOR SHALL VERIFY 4. WASTE,VENT AND SUPPLY PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SHALL 17. ACCESS PANELS ARE REQUIRED AT ALL CONCEALED VALVES AND EQUIPMENT. COMPAT181UTY OF THE SPECIFIED FIXTURE WITH THE SIZES OF FINISH CABINETRY 45'DEGREE ELBOW O1 SHEET NOTES BE AS SHOWN ON PLUMBING FIXTURE SCHEDULES.BELOW GRADE SANITARY WASTE COORDINATE LOCATION AND SIZE WITH ARCHITECT. AS IDENTIFIED IN GENERAL CONTRACTOR'S SHOP DRAWINGS. ANY DISCREPANCIES HV Engineering,Inc. PIPING SIZES SHALL BE AS SHOWN ON PLANS AND FIXTURE SCHEDULES AND BETWEEN THE SIZE OF THE FIXTURES SPECIFIED AND THE F141SH CABINETRY SIZES L 90"DEGREE ELBOW C.-ItInG Engineers SHALL NOT BE LESS THAN 2'DIAMETER. 18. STUB OUT TO SITE SERVICES 5' OUTSIDE BUILDING FOUNDATION. PIPE SIZE, SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINE IN WRITING BEFORE O1 RISER CALLOUT(RISER-1) FIXTURE UNITS, AREA DRAINED,INVERT ELEVATION,SIZES,AND SQUARE FOOTAGES SUBMITTAL � 4 WAY TEE Hall Creek Oiflce Perk AS INDICATED. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING PLUMBING FIXTURE TAG 691222oehBt. ce,WAgaoa 5. ALL SANITARY SEWER PIPING 60.0W SLAB SHALL BE INSTALLED AT A MINIMUM OF T (�� Mountlake Terrece,WA 98043 1/4' PER FT SLOPE UNLESS APPROVAL IS PROVIDED BY THE 'ADMINISTRATIVE WORK. 33. PLUMBING VENTS SHALL TERMINATE A MINIMUM 10' FROM OUTSIDE AIR INTAKES, AUTHORITY IN WRITING FOR A SHALLOWER SLOPE. IN NO CASES SHALL SEWER PER CODE. TEE Phone:(206)706-9669 PIPING BE INSTALLED AT LESS THAN 1 8' PER FT SLOPE. IN NO CASES WILL 19. INSULATE PIPING PER WSEC AND PER DIVISION 22 SPECIFICATIONS(WHICHEVER IS �1 REVISION CALLOUT(RE w hvenglneerin9.ea / GREATER). 34. LABEL ALL PIPING SYSTEMS PER THE IMC AND UPC. PIPE BREAK PIPING SMALLER THAN 4' BE INSTALLED AT SLOPES SHALLOWER THAN 1/4' PER ^��7 FOOT. PIPING INSTALLED AT 1/8'/FT SHALL BE RESIZED PER CHAPTER 7 OF THE 20. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW 35. SUPPORT AND BRACE PIPING SYSTEMS IN ACCORDANCE WITH UPC SECTION 314 ./ REVISION BUBBLE UNIFORM PLUMBING CODE AND SUPPORTING CALCULATION SUBMITTED TO ENGINEER DUCTWORK AND BETWEEN LIGHT FIXTURES.ADJUST AS NECESSARY. AND AS REQUIRED IN THE SPECIFICATIONS. PIPING SPECIALTIES FOR RENEW. 6. PROVIDE STOPS PRIOR TO ALL PLUMBING EQUIPMENT. THIS SHALL ALSO INCLUDE 21. PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM 36. ALL MATERIALS IN CONTACT WITH PIPING SYSTEMS SHALL BE COMPATIBLE FOR PX DETAIL CALLOUT(X/PX.XX) Project ACCESS OF 6" IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18' TO USE WITH AND FOR CONTACT WITH THE PIPING MATERIA.. CONTRACTORS AND TENANT IMPROVEMENT: PROVIDING INTEGRAL STOPS ON ALL SHOWER AND TUB/SHOWER VALVES(WHETHER THE SIDE OF CABLE TRAYS. TRADES SHALL VERIFY COMPATIBIUTY OF THEIR PRODUCTS NTH THE PIPING PRESSURE GAGE SPECIFIED OR NOT). PROVIDE WASTE TRAPS AT ALL DIRECT CONNECTED SYSTEMS.THIS INCLUDES,BUT IS NOT UMITED TO,FIRE STCPPING SEALANTS,FIRE �- COLUMN GRID SYMBOLS PROCESS SOLUTIONS EQUIPMENT IN ACCORDANCE WITH CODE AND THE SPECIFICATIONS. 22. COORDINATE LOCATIONS OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES OVER STOPPING COLLARS, VIBRATION ISOLATION ELEMENTS, ERMAL INSULATION, THERMOMETER --+-------- LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT EXPANSION JOINTS AND ANY MATERIAL IN CONTACT WITH PI ES. 7. PROVIDE TRAP PRIMERS AT ALL FLOOR DRAINS UNLESS NOTED OTHERWISE. MAINTENANCE. �- SIGHT GLASS Location -• --- -----= PROVIDE UNION ON UPSTREAM AND DOWNSTREAM SIDE OF ALL TRAP PRIMERS. 37. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRAP PRIMER BRANCH TAKEOFF SHALL BE FROM TOP OF MAIN DISTRIBUTION PIPE. 23. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (q ) AND BE LISTED BY VENTURI ROW METER 17216 51 st Ave NE, FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE NSF INTERNATIONAL v-�r B. INSULATE P-TRAPS EXPOSED IN UNHEATED SPACES. ROUTING ONLY. O GENERAL MECHANICAL NOTES 38. PIPE BURIAL METHODS FOR BELOW GRADE PIPING SHALL COMPLY WITH MFR ROW METER NUMBER IDENTIFICATION Industrial Park,Building B ter- 9. SEE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE ROUGH-IN DIMENSIONS 24. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REWIRED BY INSTALLATION INSTRUCTIONS,ASTM D 2321 AND ASTM F166.FAILURE TO FOLLOW � FLAG MECHANICAL NOTES Arlington,WA 98223 AND OTHER DETAILS. ALSO SEE ARCHITECTURAL DRAWINGS FOR FINISH THESE REQUIREMENTS CAN LEAD TO PIPE FAILURE. REQUIREMENTS OF ALL PLUMBING FIXTURES INCLUDING REQUIREMENTS FOR FLUSH MANUFACTURER'S INSTALLATION INSTRUCTIONS,AS INDICATED U DRAWINGS, U IN NUMBER IDENTIFICATION LEVER LOCATION AT ADA COMPLIANT TOILETS AND VALVE LOCATIONS OF ADA SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL 39. ROOF MOUNTEDPIPING SHALL BE INSTALLED ON FREE FLO TING, PREFABRICATED EXISTING WORK OR BACKGROUND Preloa.red For MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN MANUAL AIR VENT(MAV) SHOWERS.REPORT ALL DISCREPANCIES TO ENGINEER PRIOR TO ANY WORK. INSTITUTE Of STEEL CONSTRUCTION(AISC)MANUAL TREAD PADS.THE USE OF WOOD FOR SUPPORTS IS PROHIBID. NEW WOR SUPPORTS SIMILAR TO MIRO MODEL 24-R OR ROOF T BLOX ON WALKWAY INFORMATION(LIGHT LINE Q K HEAVY LINE Bond Plumbing,10. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE PLUMBING 25. IF REQUIRED FOR INSTALLATION OF PIPES AND EQUIPMENT PROVIDE ADDITIONAL I„I GAS PRESSURE REGULATOR ( g H LLC , FIXTURES AT HEIGHTS SHOWN ON ARCHITECTURAL ROOM ELEVATIONS. 40. ALL ITEMS IN CONTACT WITH POTABLE WATER SHALL COMP WITH THE NATIONAL R STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO 'REDUCTION OF LEAD IN DRINKING WATER ACT'5.3874. RELOCATE IXISTING EQUIPMENT ITEM 11. PLUMBING DRAWINGS SHOW APPROXIMATE LOCATIONS OF PLUMBING FIXTURES. MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL WATER METER OR DEVICE INDICATED MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. EXISTING EQUIPMENT OR PIPING 19023 36th Ave W.Suite G REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. COORDINATE FLOOR WYE STAINER iF� TO BE SELECTIVELY DEMOLISHED Lynnwood,WA 98036 DRAINS FOR MECHANICAL SPACES WITH MECHANICAL EQUIPMENT BEING SERVED. 26. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, 12. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE PMP-1 CONSTRUCTION INCLUDING CONCRETE EQUIPMENT PADS,FLASHING DETAILS,ETC. STRUCTURAL ENGINEER. �+ NTH TH CAPPED HOSE STAINER 'F� END BLOWDOWN VALVE TYPICAL EQUIPMENT DESIGNATION Y (PUMP) �I FLANGE UNION O POINT OF CONNECTION TO EXISTING THESE DRAWINGS WERE DEVELOPED ABBREVIATIONS ECCENTRIC REDUCER FOR RING L DESIGN BUILD WATER PIPING SYSTEMS CONCEPT.THEY ARE TO BE USED ONLY AAV AIR ADMITTANCE VALVE EA EACH HWS HOT WATER HEATING SUPPLY OC ON CENTER SHT SHEET D STEAM TRAP WITH WRrTTEN PERMISSION OF BOND AC AIR CONDITIONING EAT ENTERING AIR TEMPERATURE HWR HOT WATER HEATING RETURN OSA OUTSIDE AIR SP STATIC PRESSURE WS WATER SERVICE PLUMBING,LLC. FOR INFORMATION ABV ABOVE ECC ECCENTRIC IA INSTRUMENT AIR OAT OUTSIDE AIR TEMPERATURE SPEC SPECIFICATION HOSE BIBBS CONTACT: CURTIS BOND. AD ACCESS DOOR ECON ECONOMIZER ID INSIDE DIMENSION OA OUTSIDE AIR SQ SQUARE CWF COLD WATER FILTERED N0. DATE REVISION AFC ABOVE FINISHED CEILING EER ENERGY EFFICIENCY RATIO IE INVERT ELEVATION OD OUTSIDE DIMENSION SR SUPPLY REGISTER HOSE BIBB/WALL HYDRANT - COLD WATER(ABOVE BOOR/GRADE) AFF ABOVE FINISHED FLOOR EF EXHAUST FAN IH INSULATION HOT OPP OPPOSITE SS STAINLESS STEEL AFG ABOVE FINISHED GRADE EFF EFFICIENT,EFFICIENCY IN INCH,INCHES DV OUTLET VELOCITY SYS SYSTEM ��PIPE ANCHOR -- HOT WATER(ABOVE FLOOR/GRADE) AFUE ANNUALIZED FUEL EFFICIENCY EG EXHAUST GRILLE INFO INFORMATION OOP OVER CURRENT PROTECTION STAT THERMOSTAT (120'F TEMPERED WATER IF NOT AHU AIR HANDLING UNIT EL ELEVATION INST INSTRUMENT OU OUTDOOR UNIT AWGNMENT GUIDE INDICATED OTHERWISE) CITY OF ARLINGTON AL ALUMINUM ELEC ELECTRICAL INSUL INSULATE,INSULATION TEMP TEMPERATURE tTS TEMPERATURE/PRESSURE 140 HIGH TEMP HOT WATER 140' APPROX APPROXIMATEL EQUIP EQUIPMENT INV INVERT P PUMP TO TEMPERATURE DIFFERENTIAL TEST PORT/PETE'S PLUG OR AS INDICATED APPROVFD ARCH ARCHITECTUR ET ELECTRIC TRACED IRR IRRIGATION(NON POTABLE) PD PRESSURE DROP TDH TOTAL DYNAMIC HEAD FLEXIBLE CONNECTION IN PIPING T TEMPERED WATER ATMOS ATMOSPHERE EXIST,(E)EXISTING IU INDOOR UNIT PERF PERFORATED TEMP TEMPORARY EXH EXHAUST PF PRE FILTER THRU THROUGH FUNNEL --- HOT WATER CIRCULATING BATT BATTERY EXT EXTERIOR JAN JANITOR PH PHASE TI TENANT IMPROVEMENT `� UNLESS APPROVED BYTHE BOO BACK DRAFT DAMPER Pi PUSH ON JOINTS TSTAT THERMOSTAT ! NP NON POTABLE WATER BF BLIND FLANGE F FAHRENHEIT KW KILOWATT PLCS PLACES TYP TYPICAL /'1 BFC BELOW FINISHED CEILING FD FIRE DAMPER OR FLOOR DRAIN KWH KILOWATT HOUR PNL PANEL TRU TERMINAL REHEAT UNIT VALVES '.:J- WATER METER ■w■■r■I BHP BRAKE HORSE POWER FF FINISHED FLOOR LAT LEAVING AIR TEMPERATURE POC POINT OF CONNECTION 4/74/7i//74/7/7 HEAT TRACE FOR COLD WATER PIPE 1,�i1 BI BACKWARD INCLINED FLGD FLANGED PRV PRESSURE REDUCING VALVE UL UNDERWRITER'S LABORATORY • BALANCING VALVE SB BLDG BUILDING FUR FLOOR LBS POUND PS PIPE SUPPORT UNO UNLESS NOTED OTHERWISE PROJECT MANAGER BOTTOM OF DUCT FCO FLOOR CLEAN OUT LC LOCKED CLOSED PSV PRALSSURE SAFETY(RELIEF) UV UNIT VENTILATOR PRESSURE REGULATING VALVE DRAIN WASTE & VENT PIPING pJ BTU BRITISH THERMAL UNIT FPM FEET PER MINUTE LF LINEAL FEET UMC UNIFORM MECHANICAL CODE PROJECT ENGINEER BTUH BRITISH THERMAL UNIT PER FLTR FILTER LOG LOCATION UP UNIFORM PLUMBING CODE PRESSURE REDUCING VALVE(PRV) WASTE(ABOVE FLOOR)PIPING HOUR CITY QUANTITY BQ FOF FACE OF FLANGE LL LANDLORD UBC UNIFORM BUILDING CODE FPI FINS PER INCH LVG LEAVING UPC UNIFORM PLUMBING CODE AUTOMATIC CONTROL VALVE-TWO WAY -- - --WASTE(BELOW FLOOR)PIPING PROJECT TEAM MEMBERS CFM CUBIC FEET PER MINUTE R RELIEFim CHAR CHARACTERISTICS FSK FOIL SKRIM KRAFT LINED DUCT RA RETURN AIR UG UNDERGROUND (ELECTRIC OPERATOR SHOWN) ________________VENT CHECK (SPUNSTRAND) MAIL MATERIAL CHEM CHEMICAL INJECTION FT FEET,FOOT MA MED GAS RED REDUCER V VOLT BQ CHWS CHILLED WA SUPPLY FU FIXTURE UNITS MAX MAXIMUM READ REWIRED VAC VOLTS AC AUTOMATIC CONTROL VALVE-THREE WAY AW ACID WASTE RR REMOVE AND RELOCATE (ELECTRIC OPERATOR SHOWN) GW GREASE WASTE CHWI2 CHILLED WA RETURN FV FACE VELOCITY MPG MEDIUM PRESSURE GAS VDC VOLTS DC ENGINEERS SEAL CLG CEILING FW FEED WATER MA MIXED AIR RJ RESTRAINED JOINTS VD VOLUME DAMPER 14 - BALL VALVE GD GARAGE DRAIN CO CLEAN OUT FPTU FAN POWERED TERMINAL UNIT MBH THOUSAND BRITISH THERMAL RET RETURN VAC VACUUM � CONC CONCRETE UNITS PER HOUR RG RETURN GRILLE VAV VARIABLE AIR VOLUME -GATE VALVE C- CONDENSATE DRAIN _ CONN CONNECT OR CONNECTION G GAS MCC MOTOR CONTROL CENTER RPM REVOLUTIONS PER MINUTE VEL VELOCITY P PUMPED PIPING S AN ED of Tracy CPLG COUPLING GALV GALVANIZED MCA MAXIMUM CIRCUIT AMPS RWL RAINWATER LEADER VF VENTILATION FAN GAS COCK CS CARBON STEEL GEN GENERATOR MAT MIXED AIR TEMPERATURE VFD VARIABLE FREQUENCY DRVE ----0 FCO FLOOR CLEANOUT(FCO) _ x CSC CARSEALED CLOSED GFl GROUND FAULT MAX MAXIMUM SS SANITARY SEWER VTR VENT THROUGH ROOF REUEF VALVE -I .rw WCO WALL CLEANOUT(WCO) CSO CARSEALED OPEN CIRCUIT INTERRUPTER MECH MECHANICAL STAINLESS STEEL VOL VOLUME CHECK VALVE I Receive�\� O VTR VENT THRU ROOF CV CONSTANT VOLUME GR GRILLE MFR MANUFACTURER SA SUPPLY AIR V/PH/HZ VOLTS/PHASE/HERTZ CW COLD WATER GPM GALLONS PER MINUTE MED MEDIUM SCHED SCHEDULE r�-BUTTERFLY VALVE ® FLOOR DRAIN JUN 0 g 20 Igr 07 pT, CRD CEILING RADIATION DAMPER ❑O FLOOR SINK GV GATE VALVE MH MANHOLE SECT SECTION W/ WITH 6/5/2023 GW GRAY WATER(NON POTABLE) MIN MINIMUM,MINUTE SEER SEASONAL ENERGY EFF.RATIO -Do-REDUCED PRESSURE BAgKROW ASSEMBLY DET DETAIL MISC MISCELLANEOUS SVC SERVICE W/0 WITHOUT GWS GLYCOL WATER RETURN W WASH BALANCING/MEASURING VALVE SHEET INDEX W - DFU DRAINAGE FIXTURE UNITS GWS GLYCOL WATER SUPPLY MV MED VACUM SHT SHEET WILEWEI _ CIA DIAMETER SD SMOKE DETECTOR WC WET BULB WATER CLOSET PO.OT SHEET TITLE DIM DIMENSION HP HORSE POWER N NORTH,NEUTRAL SL SOUND LINING WC PLUMBING COVER SHEET '/� PLUMBING COVER SHEE DISCH DISCHARGE HPFS HIGH POINT FINISHED SURFACE NA NOT APPLICABLE SV SOLENOID VALVE WCO WALL CLEAN OUT REFERENCE CODES PO.02 PLUMBING SCHEDULES vJ DI DUCTILE IRON NC NORMALLY CLOSED SW SOCKET WELD WC WATER GAUGE PLOD UNDERGROUND PLUMBING PLAN HR HOUR WHA WATER HAMMER ARRESTER IBC INTERNATIONAL BUILDING CODE-2018 P1.01 UNDERGROUND ENLARGED PLANS DMPR DAMPER HTG HEATING NIC NOT IN CONTRACT STA STATION IMC INTERNATIONAL MECHANICAL CODE-2018 1Yr WATER TANK P2.OD LEVEL 1 PLUMBING PLAN ` PROJECT No. ON DOWN HT HEIGHT NO NUMBER OR NORMALLY OPEN STD STANDARD UPC INTERNATIONAL PLUMBING CODE-2018 c DP DIFFERENTIAL PRESSURE NG NATURAL GAS SF SUPPLY FAN WT WEIGHT IFGC INTERNATIONAL FUEL GAS CODE-2018 P2.01 LEVEL 1 ENLARGED PLANS 2023-050 HVAC HEATING VENTILATION AND AIR WIR,W WATER IFC INTERNATIONAL FIRE CODE-2018 P3.OD PLUMBING DETAILS KE/FIRE DAMPER NEC NATIONAL ELECTRICAL CODE-2017 � DATE DR DRAIN CONDITONING NTS NOT TO SCALE SFD SMO P4.OD ISOMETRIC RISER DIAGRAMS JUNE 5,2023 DWG DRAWING HW HOT WATER S.I.O. SUPPLIED AND INSTALLED BY WSEC WASHINGTON STATE ENERGY CODE W PROJECT NETWORK PATH HWC HOT WATER CIRCULATING 02 OXYGEN OWNER/OTHER ADA AMERICAN DISABIUTY ACT STANDARDS-2010 ^^ ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS- LL A17.1 -2007 W/2DO8 ADDENDA SAFETY CODE FOR REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER ELEVATORS AND ESCALATORS NFPA NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED BAR MEASURES ONE INCH �O O 13D,13R,OR 13(AS APPLICABLE)-2016 HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERMCE,IS ON ORIGINAL DRAGWNG THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE 0"_I" ■ USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. PLUMBING CALCULATIONS 2018 UNIFORM PLUMBING CODE PER TABLE 702.1 AND TABLE A-2.7 BUILDING SUMMARY MIN.SIZE DOMESTIC WATER SEWER DFU DOMESTIC WATER O TRAP/ARM PER HWPER PER TOTAL PER - HOT WATER P/PESIZINGTABLE COMMERCIAL ENERGY EFFICIENCY TABLE C404.3.1 FIXTURE TYPE IN. OTV FIXTURE TOTAL FIXTURE HW FIXTURE TOTAL WSFU BASED ON 2018 UPC CHART A2.1 DRINKING FOUNTAIN,WATER COOLER(ASSEMBLY) 1.25 1 0.75 0.75 -- - 1 1 PIPE MATERIAL TABLE C403.10.3 PIPING VOLUME & MAXIMUM FLOOR DRAIN-EMERGENCY 2 5 -- -- -- - 0 0 TYPE L COPPER LAVATORY,SINGLE 1.25 10 1 10 0.75 7.5 1 to MINIMUM PIPE INSULATION THICKNESS(in.)[a] PIPE LENGTHS FLUSH TANK SINKS -- -- -- -- -- -- - VELOCITY<=BFPS FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE(in.) SPECIAL PURPOSE 3 1 2 2 1.5 1.5 6 6 TEMPERATURE NOMINAL PIPE VOLUME MAXIMUM PIPING LENGTH(FT.) KITCHEN,DOMESTIC 2"DRAIN 1.5 1 1.5 1.5 1.125 1.125 2 z Psumo Fr a RANGE AND CONDUCTIVITY MEAN RATING <1 1 TO<11<2 1$TO<4 4 TO<8 x8 SIZE(IN.) (FLOZ.PER PUBLIC LAV OTHER SERVICE OR MOP BASIN-PUBLIC 2 OR 3 1 3 3 2.25 2.25 3 3 USAGE F h{ft�2F F b TEMPERATURE,f FOOT LENGTH URINALS WSFU RANGE MIN MAX ( ) Btu{in ) FAUCETS FIXTURES/APPLIANCES PRIVATE,1 GPF,FLUSHOMETER,.7s"SUPPLY 2 6 3 18 2 12 PIPE SIZE") 105-140 0.21 -0.28 100 1.0 1.0 1.5 1.5 1.5 1.5 2.0 43.D WATER CLOSETS 1 _ _ vz 0 4 40-60 0.21 -0.27 75 0.5 0.5 1.0 1.0 1.0 �" 3.0 0.5 21.0 1.6 GPF FLUSHOMETER VALVE,PUBLIC 3 11 5 55 -- - 4 44 3/4 4.5 11 <40 0.20-0.26 50 0.5 1.0 1.0 1.0 1.5 HV Engineering,Inc. TOTALS 36 90.25 12.375 78 1 12 22 1" $.Q 0.$ 13.D 11/4 23 So [a] FOR PIPING SMALLER THAN IY2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, 1Ya" 8.0 0.5 8.0 1 uz 51 100 REDUCTION OF THESE THICKNESSES SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN Consulting Engineers 2 101 265 FOOTNOTE[b]BUT NOT TO A THICKNESS LESS THAN 1 INCH. 112- 11.0 0.5 6.0 Hall Creek Office Park 2018 UPC APPENDIX A WATER SERVICE CALCULATIONS COPYRIGHT HV ENGINEERING b FOR INSULATION OUTSIDE THE SLATED CONDUCTIVITY RANGE,THE MINIMUM THICKNESS SHALL BE 2"AND LARGER 18.0 0.5 4.0 6912 220th St.SW,Suite 303 o ater aping to FV System(FV=Flush Valve,FT=Flush Tank) [] (� Mountlake Terrace,WA 98043 Hot Water Pi in to be Sized Based on a PIPE MATERIAL DETERMINED AS FOLLOWS: P 9 FT System(FV=Flush Valve,FT Flush Tank) PIPE MAINS FIX UNIT GPM SIZE TYPE L COPPER �" Phone:(206)e0e6-9669 COLD WATER 90 64 SEE PLANS FLUSH TANK T=rl(1 +t/r)"(KA)-1) -.hvengin ring.biz HOT WATER 12 8 SEE PLANS VELOCITY<-5 FPS WHERE: T=MINIMUM INSULATION THICKNESS BLDG SUPPLY PRESSURE(PSI): 72.0 PS0100 FT 8 r=ACTUAL OUTSIDE RADIUS OF PIPE PIPE LOSS BETWEEN BUILDING AND TENANT SPACE(PSI): 22.0 AVERAGE 4 PSI/1W AT 530 FEET WSFU RANGE MIN MAX t=INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE Project SUPPLY PRESSURE FOR PIPE SIZING TENANT(PSI): 50.0 PIPE SIZE" K=CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE ] 112 0 4 APPLICABLE FLUID TEMPERATURE(Btu•in/h•ft"2•F) TENANT IMPROVEMENT: COLD WATER PRESSURE LOSS: 3/4 4.5 9 k=THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID PROCESS SOLUTIONS ELEVATION CHANGE(PSI) 4.3 10 FEET AT 0.433 PSI/FT 1 10 16 TEMPERATURE. MIN.RESIDUAL PRESS.AT REMOTE FIXT.(PSI) 30.0 (TYPICALLY PROVIDE 25 PSIG-5 PSIG FOR TXV) 1 1/4 17 16 [c] FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING,REDUCTION OF THESE THICKNESSES BY 1Y22 TOTAL PRESSURE LOSS: 34.3 COPYRIGHT HV ENGINEERING INCHES(38mm)SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE[b]BUT Location 78.0 PIPE MATERIAL NOT TO THICKNESSES LESS THAN 1 INCH(25mm)). 34.3 TYPE L COPPER Ave NE, AVAILABLE PRESSURE(PSI) 43.7 FLUSH VALVE 7 St VELOCITY<.BFPS Industrial Parkk,, Building B LONGEST PIPE RUN WITHIN TI(FT) 100.0 43.67 X 100 FT Arlington,WA 98223 X 1.25(FITTINGS) 1.25 125.0 125 FT PSY100 FT 8 WSFU RANGE MIN MAX Prepared For Friction Loss Not to Exceed 34.9 PSI/1 DOFF LOSS PIPE SIZE(") ELECTRIC WATER HEATER SCHEDULE PUMPS Size All Piping Based on a Friction loss of.®PSIADOFF LOSS 1 0 3.25 Bond Plumbing, LLC and max velocity based on installation standard. 1 114 4.25 12 MARK NUMBER CP-1 CP-2 1112 13 35 EQUIPMENT NUMBER WH-1 Ill SERVICE DESIGN MAX FT 2 36 135 LOCATION JAN 130 ADJACENT TO RESTROOM 160 SIZE MAINS AND RISERS PER BELOW PSIMOOFT LOSS PER APPL. 21/2 136 345 UNIT LOCATION JANITOR 130 ADJACENT TO RESTROOM 110 JAREA 19023 36th Ave W.Suite G MAIN%LENGTH OF TOTAL PIPE 90% 8 113 COPYRIGHT HV ENGINEERING RISERS/UNIT PIPING LENGTH OF TOTAL PIPE 10% 8 13 SYSTEM 120 DEG 120 DEG Lynnwood,WA 98036 TOTAL ALLOWABLE PSIG FRICTION LOSS 43.7 SYSTEM SERVED DOMESTIC HOT WATER DOMESTIC HOT WATER DOMESTIC DOMESTIC ACTUAL TOTAL FRICTION LOSS 10.0 TYPE CARTRIDGE CARTRIDGE SAFETY FACTOR PSIG,MUST BE POSITIVE NUMBER) 33.7 TYPE TANK HEATER TANK HEATER SERVICE CONDITIONS NOTE,CALCS CONSERVATIVE BECAUSE NO CREDIT IS TAKEN CAPACITY-GPM 2 2 FOR LOWER THAN MAX FLOW RATES IN EACH PIPE SECTION, CAPACITY-GALLONS 50 50 TOTAL HEAD-FT 15 15 RECOVERY(GPH @ 90 DEG RISE 27 27 FLUID WATER WATER THESE DRAWINGS WERE DEVELOPED SERVICE CONDITIONS TEMPERATURE-DEG F 140 DEG F 140 DEG F FOR EXCLUSIVE USE BY BOND LVG WATER TEMP-DEG F 140 140 UNIT CONDITIONS PLUMBING,LLC ON A DESIGN BUILD ENERGY FACTOR SPEED-RPM 3250 3250 CONCEPT.THEY ARE TO BE USED ONLY PLUMBING FIXTURE SCHEDULE ELECTRICAL CONNECTIONS INLET/OUTLET 3/4"SWEAT 3/4"SWEAT WITH WRITTEN PERMISSION OF BOND NUMBER OF STAGES 1 1 MOTOR PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. SYMBOL ITEM WASTE VENT CW HW SPECIFICATION REMARKS KW INPUT/STAGE 4.5 4.5 ENCLOSURE TYPE WC-1 WATER CLOSET-FLUSH VALVE 3 2 1 - SEE CONTRACTOR'S SUBMITTALS 1.28 GPF TOTAL KW 5.0 5.0 HORSEPOWER-MINIMUM t/25 1125 NO. DATE REVISION FLOOR MOUNTED VOLTS-PHASE-HERTZ 240/1/60 240/1/60 SPEED-RPM 3250 3250 WCAA WATER CLOSET-FLUSH VALVE(ADA) 3 2 1 - SEE CONTRACTOR'S SUBMITTALS 1.28 GPF NOTES [11,[21,[31 [11,[21,[31 VOLT.-PHASE-HERTZ 115/60/1 115/60/1 FLOOR MOUNTED MANUFACTURER-DESIGN BASIS MANUFACTURER-DESIGN BASIS TACO 008-BRONZE TACO 008-BRONZE UR-1 URINAL 2 1-1/2 314 - SEE CONTRACTOR'S SUBMITTALS 1.0 GPF MAKE RHEEM RHEEM NOTES [11 [i] MODEL PRESTIGE PR050 PRESTIGE PRO50 REMARKS UR-1A URINAL(ADA) 2 1-12 3l4 - SEE CONTRACTOR'S SUBMITTALS 1.0 GPF SIZE EIGHT FULL/DIAMETERMEIGHT 592#/22-1/4"/61-3/4" 592#/22-1/4"/61-3/4" (1]PRO VIDETIMERIAOUASTAT REMARKS 6/5/2023 [11 MOUNT ON R-10 INSULATED PAD. L-IA LAVATORY(ADA) 1-1/2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM [21 PROVIDE SEISMIC STRAPS. COUNTER MOUNTED [31 WEIGHT=OPERATING WEIGHT L-2A LAVATORY(ADA) 1-112 1-W 112 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM WALL HUNG 6/5/2023 8-1 BREAK ROOM SINK 2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM PARTNER IN CHARGE S-2 UTILITY SINK 2 1-1/2 112 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM EXPANSION TANKS SB PROJECT MANAGER DF-1A DRINKING FOUNTAIN 1-1/2 1-1/2 112 - SEE CONTRACTOR'S SUBMITTALS EQUIPMENT NUMBER ET-1 ET-2 DJ DUAL HEIGHT(ADA) I I I I I PROJECT ENGINEER MS-1 MOP SINK 3 2" 112 112 SEE CONTRACTOR'S SUBMITTALS SERVICE BQ LOCATION JAN 130 ADJACENT TO RESTROOM 116 PROJECT TEAM MEMBERS SYSTEM DOMESTIC HW DOMESTICHV/ JM 6/5/2023 NOTE 1-COORDINATE FINAL FIXTURE SELECTION WITH OWNER PRIOR TO PROCUREMENT TYPE ORIENTATION VERTICAL VERTICAL CHECK LINING YES YES BQ MISCELLANEOUS PLUMBING EQUIPMENT SCHEDULE JASME NO NO SERVICE CONDITIONS ENGINEERS SEAL ID DESCRIPTION MAKEIMODEL CERTIFICATIONS REMARKS CAPACITY-GALLONS 6.4 6.4 FD-1(E) FLOOR DRAIN(FD) SEE CONTRACTOR'S SUBMITTALS MEDIUM DUTY.8-1/2"ROUND CAST IRON GRATE.PIPE SIZE PER PLAN. ACCEPTANCE-GALLONS 3.2 3.2 EMERGENCY ONLY INSULATION NA NA A� FLUID WATER WATER OF ASy FCO FLOOR CLEANOUT SEE CONTRACTOR'S SUBMITTALS PRESSURE-PSI 150 150 TEMPERATURE-DEGF 140 140 TMV-1 MIXING VALVE SEE CONTRACTOR'S SUBMITTALS ABBE 1017 AT WATER HEATER UNIT CONDITIONS INLET&OUTLET TAP SIZE 3/4" 3/4" 5" TMV-2 MIXING VALVE SEE CONTRACTOR'S SUBMITTALS ABBE 1070 POINT OF USE AT LAVS WEIGHT FULL 26 26 DIAMETER AND HEIGHT 12"x1T 12"x18" MANUFACTURER-DESIGN BASIS AMTROL ST-12C AMTROL ST-12C 6/5/2023 TP-1 TRAP PRIMER SEE CONTRACTOR'S SUBMITTALS PRESSURE ACTIVATED REMARKS � 6512023 6/5/2023 w nTLPLUMBING SCHEDULES PIPING SYSTEM AND SPECIFICATION SCHEDULE v) SYSTEM LOCATION MATERIAL JOINT METHOD REMARKS PIPE INSULATION - WASTE&VENT BELOW GROUND SCH.40 PVC(SOLID CORE) SOLVENT WELD PROJECT 10. DOMESTIC WATER BELOW GROUND COPPER TYPE K BRAZE 2023-050 DOMESTIC WATER BELOW GROUND PFX EXPANSION COUPLING DATE JUNE 5,2023 WASTE&VENT ABOVEGROUND PVC-SCHEDULE 40 SOLVENT WELD W PROJECT NETWORK PATH DOMESTIC WATER 2"&SMALLER ABOVE GROUND COPPER TYPE L SOLDER OR PROPRESS INSULATE PER WSEC NOTES: 1.RECIRC LOOP MUST BE INSULATED PER ESDS AND WASHINGTON STATE ENERGY CODE,WHICHEVER IS GREATER. REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ;H O.O L A THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. 42> '92 13 14 5 6 17 �q O zI I I IA 4"RL u4 6' L UP_ 6"RL C� �.E,..�....................... Y4"CW UP TO O. ...................... "C UP TO >K--111 zi 114 1' ED o o HV Engineering,Inc. C.EI Engineers -—-—-—-—---Ill .................. -—-—--ELL :� Hall Creek OfficePark M IL 61 STRIP- 4"W UP — 6912 220th St.SVV,Suite 303 UfF T��C�40UT FOR Mountlake Terrace,WA 98043 FUT =L7 POUR 6"WCM Phone:(206)706-9669 ­hVergIneenng.biz BELOJIFINISHED FLOOR. FCb FCO FCO F ------------------------t-------- 0 FCO ®COFCO ... ........................... -------- -T--------r -------- -- FCC ------------------- -3- 4 Project L— L TENANT IMPROVEMENT: PROCESS SOLUTIONS 2N 1: MANUFACTURING Location 17216 51 st Ave NE, FT7 F7 Industrial Park,Building B Arlington,WA 98223 II Ll — — — — — — — Prepared For Ell I-J--i C Bond Plumbing, LLC DEMISING AALLS TO INCLUDE 19023 36th Ave W.Suite G II I Lynnwood,WA 98036 3/4"�S'B'WAINRCOT T F F- THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND FCO FC0 CO 6 F PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS.BOND.T, NO. DATE REMSION WAREHOUSE —1 VA91% �--6"W@1% III PoORWER A DATA DROP WORK STATIONS. �/,"CW UP TO "CW UP TO HB-1 6 W@ �6 1 6 LE.- 4+/ @% 6"W@1% S13 :�7PARTNER IN CHARGE 1 6"WO17 LF.- 4"+/- -1 E-84"+/- PROJECT MANAGER BELOW WISHED FLOOR BELOW FINISHED FLOOR B W FINISHED FLOOR DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS im CHECK -TD Bo o ENGINEERS SEAL A. 100 (1�2 13 14 5 6 7 18 of 5 6/5/2023 UNDERGROUND PLUMBING PLAN EASTERN END I SCALE: 1'-0" ITUE 0 W UNDERGROUND PLUMBING PLAN PROJECT NO. 2023-050 DATE JUNE 5,2023 W PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHEET—NumBER BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF TV ENGINEERING,INC.AND IS NOT TO BE 0" P1 .00 USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC ACCORDINGLY. HV Engineering,Inc. a"w Poc To(L)6"w Consulting Engineers Hall Creek Office Park 6912 220th St.SW,Suite 303 Mountlake Terrace,WA 98043 E Phone:(206)706-9669 www.hvengineering.biz 2"W UP(1 DFU) r I UTILITY 4"W POC TO(E)6"W 13, 2"W UP Project JANITOR STORAGE I W/CD 30 J 3"W UP I DFU) (2 DFU) TENANT IMPROVEMENT: PROCESS SOLUTIONS 7�2"V UP I I w/CD [] I Location (3 DFU) I I I Industrial ParkeBuilding B UP TO ----------8 DFU) 2"W UP TO WOMEN 1 f2"W(3 D I j I Arlington,WA 98223 r F DFU) 32 ! I II Prepared or --- ( Pea dF P(0 DF W( DFU) I Bond Plumbing, LLC W(35 EIF_U)- NP Till I ' z ) I ', - - _ ------- - ----- -- -- ----- -- - -- - -_-_ 4--=D________-- ---------- BREAK A9S036 DFU "W(51 DFU) I ;" t Ave Suite Lynnwood,W 4 (48 DFU) '�2"W UP(1 DFU) 3"W UP TO WCO W (47 DFU) 2'V UP(8 DFU) ! 4"W-41_DFU 2°W UP(2 DFU) (4 TYP.)I --( ) 4"W UP TO FCO I ,________ I 3•14(9 DFU) THESE DRAWINGS WERE DEVELOPED MEN W( DFU) 4"W(23 DFU),\ FOR EXCLUSIVE USE BY BOND .'I ' ----{ PLUMBING,LLC ON A DESIGN BUILD -____-_ FD(O DFU) I 133 2"W UP 4"W(21 DFU)\ 7 i,�ii i� )-----_' ----- --X}----3�WJ DFU) CONCEPT_THEY ARE TO BE USED ONLY 3I 1 OFU 2"W UP TO W/CO 3 W(21 DFU) . 3°W DN W UP(4 DFU) WITH WRITTEN PERMISSION OF BOND tf PLUMBING,LLC. FOR INFORMATION I I (2 DFU) CONTACT: CURTIS BOND. oo— TT I ( 3"W UP --_-)' NO. DATE RENSION 2'V UP f ( ) YW UP j 4 2" 2 DFu ! (erveWD�Ez (a DFu) L ET ❑ ❑� J W/COP ---- 2"W UP T Ell I - -- (0 DFU 2"W UP (6 DFU) ---------- W/CO FD(0 DFU - ------- ----- -- -- W UP W CO (2 DFU) I (2 DFU) 2"W UP TO 2"W UP TO FD(0 DFU) FD(O DFU) I PARTNER IN CHARGE SB PROJECT MANAGER DJ ENLARGED PLUMBING PLAN - UNDERGROUND ENLARGED PLUMBING PLAN - UNDERGROUND PROJE BQCT ENGINEER OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS PROJECT TEAM MEMBERS JM SCALE: J4°=1'-0" P1.01 SCALE: J4"=V-O" CHECK BQ ❑ ❑ I■ ENGINEERS SEAL A. OF WASy 2 5� TONAL�'� 6/5/2023 LL1 nnUNDERGROUND ENLARGED PLANS G PROJECT N0. 2023-050 DATE w JUNE 5,2023 /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHET NUMBER BAR MEASURES ONE INCH p 1 01 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„-t„ ■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. Ito p 4 RL,OL U TO RO F DRAT IS 6890 S. . 4"COMBINED RL DN COME N "COMB 4"COMBINED RL ON (3040S.F.) 4' 9400 .F.) (9400 .F.) 6" OMBINED RL ON 1 (6890 S.F.) (i HB � (940 S.F.) _ O RD 1 RD RD RD 1 CW ON �>"—` 1 1 ,° -Y4"CW DIN 1 HV Engineering,Inc. °w �°/" OD ODo- Consulting Engineers 4"RL,OL U � 1 4"RL,OL UP TO J/ 1 1 4'RL,OL UP TO Hall Creek Office Park INS ROOF DRAINS 1y2"CW FUTURE TENANT STUB ROOF DRAINS 6912220th St Sw,Suite 303 9400 S.F.) - (9400 S.F.) PROVIDE BALL VALVE�\ (9400 S.F.) 1Y2"CW FUTURE TENANT STIR Mountlake Terrace,WA 98043 \\\\ PROVIDE BALL VALVE n n n—. .—.—.—.—. .—. .—.—.—. — Phone:(206)706-9669 Mhvengineerng.bi z 2J'2'CW 2"CW —.—.—.iJni.—.—. w-3VTR o�3VTR W 3' R 3"VTR—'O 3"VTR 3 VTR 1YJz"CW FUTURE TENANT STUB ° o p 1J�"CW FUTURE TENANT STU I I Project PROVIDE BALL VALVE o I PROVIDE BALL VALVE J q TENANT IMPROVEMENT: PROCESS SOLUTIONS P201 MANUFACTURING Ol ao I Location I I 17216 51 st Ave NE, Industrial Park,Building B — — — — J Arlington,WA 98223 Prepared For TM �7FM Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. NO. DATE RENSION WAREHOUSE 141 r --------------------- I "CW ED "CW ON PARTNER IN CHARGE SB PROJECT MANAGER DJ PROJECT ENGINEER RWNSPCI.- BQ T(ILS,T PROJECT TEAM MEMBERS D I D CHECK BQ S S Z Z ENGINEERS SEAL FT T IT A. OF WASy 2 TONAL'I'�� T� 6/5/2023 LEVEL 1 PLUMBING PLAN - EASTERN END SCALE: J(e"=1'-0" LU nnLEVEL 1 PLUMBING PLAN G PROJECT N0. 2023-050 DATE JUNE 5,2023 w /'� PROJECT NETWORK PATH a— REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ;H P2.00 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. - �1�'CW POC TO(E)1}¢'CW / 2"CW POC TO(E)2"CW HV Engineering,Inc. I Consulting EnOlneers Hall Creek Office Park 6912 220th St.SW,Suite 303 f _ Mountlake Terrace,WA 98043 E $ ET CP 3.00 2'CW(64.$WSFU) I Phone:(206)706-9669 —h—gineering.biz I I I I �4'HW(8.625 Ill UTILITY 131 3"V POC TO(E)3'VTR I Project JANITOR STORAGE 13p I i TENANT IMPROVEMENT: f i *'HWC 2 DA I PROCESS SOLUTIONS }¢"CW(2.5 WSFU) •HW(6.375 WSFU) i 3"V POC TO(E)3"VIR Location I � LJ LJ 1 2"Cw I (5s.s WSFU)I _ _ _ 17216 51 st Ave NE, --- --- -- I WV(3 DFU) I Industrial Park,Building B rr Arlington,WA 98223 ------- ----------------+---1 3• 0 �) I j 1}�°CW(31.5 WSFU) i)FV(3 2- (32 DFU j I 1} DFU) Q - ---- -- --1- --------------------------------------' Prepared For 2� DFU) -- - 24 — ------ ----- "V(51 DFU) ; ! Bond Plumbing, LLC 2"CW 1A -- LAY: 1A I f (57.25 WSFU) -r ( `--, ------ ----- - I _ - I 3"V 48 DFU I Wl 3.375.-` ;-- _ ---------------- -I -----1 ( ) i 19023 36th Ave W.Suite G - I --------I I - - I - r---- ----- -- •HW 1.125 WSFU I ', 2/V 1}¢"CW(30.37 )(21 DFU) ` Lynnwood,WA 95036 u b__ u - b b b bu u H�, R z cw s. ) .W 9 z'v(z3 Fu) h"CW(29.25 WSFU ' ` t1 251) i 2"V(11 DFU) 2"V(9 DFU)) e e 1A - MEN 1A 1 H j 4"FCO �_____________________________ __ __ _ ��e__-_�__--_-__� •__`_r_ --- THESE DRAWINGS WERE DEVELOPED I *"HW(4.875 ) T FOR EXCLUSIVE USE BY BOND 1A 1 1 1 133 " i __________ r 1 - 13'7;WSFU) PLUMBING,LLC ON A DESIGN BUILD CW(3,45 3' _ -___.——_; i r I 2"V(5 DFU) CONCEPT.THEY ARE TO BE USED ONLY )�" ( WI I ---„, TI 1 CW WITH WRITTEN PERMISSION OF BOND --------y--I- -- PLUMBING,LLC. FOR INFORMATION 1WCW(12 WSFU) 'y'"CW(5.25 N5�U) � I I I (5.75 WSFU) CONTACT: CURTIS BOND. A NO. DATE RENSION UR UR 1A P3.00 2 2 2 O NISEX Y2"H CFO}�1•--' -----'UNISEX 1WV(6 DFU) z'v po DFu) r r ___,;- �n�®''� 1 $J FD 1)FCW(25.2 -- - --- -- I x-CW(11. ) 0 � IWV 2 U - I WCW(1.5 WSFU) I )FHW(0.75 WSFU) PARTNER IN CHARGE SB PROJECT MANAGER DJ ENLARGED PLUMBING PLAN - 1ST FLOOR ENLARGED PLUMBING PLAN - 1ST FLOOR PROJE BQCT ENGINEER OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS PROJECT TEAM MEMBERS SCALE: J4"=1'-0" P2.01 SCALE: J4"=1'-0" JMCHECK BQ ❑ ❑ I■ ENGINEERS SEAL A. OF WASy 2 5� 6/5/2023 UJ nnLEVEL 1 U) ENLARGED PLANS G PROJECT N0. 2023-050 DATE JUNE 5,2023 W /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHET NUMBER BAR MEASURES ONE INCH ^ O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„—t„ L■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. MAX 1)FCW PIPE )F BRANCH ADJUSTABLE STRAINER NON—SHRINK GROUT \_ _ _ — YF BALL ACCESS DOOR(AT RECESSED F— UNION TYP. FINISH LOCATION IN FINISHED SPACES) OFFSET HOT WATER MAIN TO HAND DEPRESS DRAIN 1/4" TO 1/2" FLOOR I I PPP P2-500 O WHERE NOT ALREADY SLOPED I PRIME RITE TRAP SINK/LAVATORY AS NEEDED. PRIMER VALVE / Y/ MANUFACTURER'S THERMOSTATIC DISTRIBUTION UNIT TEMPERING VALVE DHERE APPLICABLE f DRAIN AFFOR EVERY WHERE APPLICABLE CLAMPING RING 20'OF PRIME LINE I I NOTE: ROUTE HOT WATER PIPING MAIN }fit"COPPER TO FLOOR OVER TO LAVATORY SUCH THAT NO MORE DRAIN,TRAP MAKE UP THAN 2'OF"DEAD"BRANCH PIPE EXISTS. WATER(TYP.)QTY.AS TYPICAL FOR ALL AND LAVATORIES. REQUIRED(MAX 2) HV Engineering,Inc. PROVIDE TRAP PROVIDE WATERPROOF TYPICAL LAVATORY PRIMER MEMBRANE AT ALL FLOOR Consulting Engineers DRAINS, FLOOR SINKS, AND L — — — — J Hall Creek Office Park TRENCH DRAINS. 6912 220th St.Sw,suite 303 Mountlake Terrace,WA 98043 DRAIN PIPE n FLOOR DRAIN DETAIL n TRAP PRIMER DETAIL n TYPICAL LAVATORY PIPING DETAIL Phone:(206)706-9669 www.hvegineering.biz P3.00 SCALE: NTS P3.00 SCALE: NTS P3.00 SCALE: NTS Project TENANTIMPROVEMENT: PROCESS SOLUTIONS Location 17216 51 st Ave NE, Industrial Park,Building B GATE VALVE(TYPICAL) Arlington,WA 98223 UNION(TYPICAL) CIRCULATING PUMP Prepared For CHECK VALVE(TYPICAL) � CE (TYPICAL)VALVE �" Bond Plumbing, LLC "HW 19023 36th Ave W.Suite G (2 GPM) Lynnwood,WA 96036 EXPANSION CW/HW/HWC WITHIN 15' TANK OF WATER HEATER TO BE COPPER(TYP.) 140 140 SIZE PER PLANS t INSTALL PER I " E2 THESE DRAWINGS WERE DEVELOPED MANUFACTURER'S TV SIZE PER PLANS FOR EXCLUSIVE USE BY BOND INSTALL PER PDI 1 PLUMBING,LLC ON A DESIGN BUILD STANDARDS AND REQUIREMENTS CONCEPT.THEY ARE TO BE USED ONLY MANUFACTURER'S HOT OR COLD WATER SUPPLY IF BRANCH IS GREATER THAN 20' SIZE PER WITH WRITTEN PERMISSION OF BOND INSTRUCTIONS LONG,PROVIDE ANOTHER WHA IN PLANS MIDDLE,EACH SIZED FOR HALF PLUMBING,LLC. FOR INFORMATION THE SIZE PER PLAN FIXTURE UNITS CONTACT: CURTIS BOND. PDI THERMOMETER — SIZE IF HORIZONTAL BRANCH IS LESS No. DATE REVISION f THAN LONG,PROVIDE ONE YMA AT END OF LINE RELIEF VALVE,PRESSURE AND r? x TEMPERATURE.PIPE DRAIN FULL PDI SINGLE FIXTURE MULTIPLE FIXTURES SIZE TO MOP SINK BELOW STRAP WATER HEATER SIZE u TANK TO WALL FOR SEISMIC RESTRAINT.TWO PC TO PROVIDE WATER HAMMER PLACES. PIPE FIXTURE FIXTURE UNIT TABULATION ARRESTERS BY SIOUX CHIEF, SZE UNIT LOAC FIXTURE COLD HOT PRECISION PLUMBING PRODUCTS, A )2" 1-3 WATER CLOSET g __ WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0—RING CONSTRUCTION, B 1" 4-12 LAVATORY/HAND SINK 1 1 HAVING PDI#WM-201,ASSE#1010 1,2 AND ANSI#A712.26.1M CERTIFICATION. C 1" 13-25 KITCHEN SINKS 1.5 1.5 INSTALL IN HORIZONTAL OR VERTICAL D 1Y" 26-50 MOP BASIN 3 3 POSITION,BUT NEVER UPSIDE DOWN. DRAIN VALVE,TYP. INSTALL IN LINE NTH WATER FLOW PARTNER IN CHARGE RAIN TO I E 1)¢" 51-85 URINAL 5 -- UNITSTIAS SHOWN ON IF SON THESDRAWINGS APPROVED IZE THE W.H.DLOCATION R10 INSULATION UNDER SB AND/OR PER THE TABLES SHOWN FLOOR/PLATFORM TANK PER CODE PROJECT MANAGER ABOVE. DJ DRAIN PAN PROJECT ENGINEER n WATER HAMMER ARRESTERS n WATER HEATER DETAIL BQ PROJECT TEAM MEMBERS P3.00 SCALE: NTS P3.00 SCALE: NTS JM CHECK BQ ENGINEERS SEAL A. pF WASy 2 5� ZONAL�'� 6/5/2023 LL1 nnISOMETRIC RISER DIAGRAMS G PROJECT N0. 2023-050 DATE JUNE 5,2023 W /'� PROJECT NETWORK PATH 0— REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES INC. A.O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING P3.00 r HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. �4"W POC TO(E)4"W 2"V POC TO(E)3"V�� ^ \ \ \ �2"V(5 DFU) 1)h•V(3 DFU)-' y ��„% 3•V(51 DFU) I I \ DF I IN, I \ ; 1A T'T2"V(4 DFU) 2"V(9 DFU) I I I 3°V(48 DFU j �//�2•W(1 DFU) // /� -2"W(3 DFU) / 2"V(11 DFu,`\ ��' WC HV Engineering,Inc. Consulting Engineers �Y 2'V 10 DFU `�' \ � / 1z ( ) I I I I Hall Creek Office Perk 2"V 21 DFU I j.� ,}¢"V($DFU \ i j (51 DFU) ( I2°t/(1D DFU) I I 1� I 6912220th St.SW,Suite 303 3°V 45 DFU)/ 4"W POC TO(E)4"W 3"W(9 DFU) j UR j e j Mountlake Terrace,WA 98043 ( ) ( ```` i 3"W(9 DFU i 1 A i // \ A Phone:(206)706-9669 2"V 3 DFU 3°V(39 DFU I \�� L / I —.homer,ineerin `�/ \ �� �•�,-2"V(10 DFU) R I I/ FD ,...,.2"W(5 DFU) \ g g.biz 1)67V(7 DFU \ i 1A \ /fG^ \ �`�� i i 1A 3"V(32 DFU}\T�?, ��`\ ``i I L / 2"V POC TO(E)3"VJ ` \�'' r/� `�i�`� /� 2•W 1 DFU r� 2"V(24 DFU i f I 1A\ ` 1 1A/ \ ``` ` \ I S I I i .\ \ i ( ) Project I`\� Tv/ \ i I i I /`�• 4"W(48 DFU) 2"v(23 DFU)-� \ i �/ i TENANT IMPROVEMENT: 2'V(8 DFU) I I L �`�i 4"W(23 DFU) \I I I \2-W(0 DFU)/iPROCESS SOLUTIONS ( �: I '' 1A�' i 4"W 21 DFU I\ / i 1)h"V(2 DFU) 2-V 8 DFU I I e I ( )- / e � /, I ; Location we i \ 1 `I)TV(6 DFU) I �n y / FD i I i e i i `4 I Ms i 1 i i I w 41 DFU) �, / \ ; we 17216 51 st Ave NE, /�•W(35 DFU) % I Ij/ // I 1A , AIndustria nl,WA 98223ng B \\ 2"W(0 DFU}e\ I /1c 2 w(s DFu)J r '\;\1A I \I iD 1A \ JJI Prepared For \ 1n 3"W(10 DFU) 3"W(10 DFU) A�. Bond Plumbing, LLC \ I / 4"W(11 DFU) 3"W(3 DFU \ �l2"W(0 DFU) UR i �/ 2 W(2 DFU) e23 36th Ave W.Su yV Lyn 8 3 // nnwood,WA 6ite G `4-W(11 DFU)` 3"WCO RISER DIAGRAM - 1ST FLOOR RISER DIAGRAM - 1ST FLOOR THESE DRAWINGS WERE DEVELOPED MEWS AND WOMEN'S RESTROOMS 2 MEN'S AND WOMEN'S RESTROOMS FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD P4.00 SCALE: NONE P4.00 SCALE: NONE CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. 2"CW POC TO (E)2°CW ^CW HWC N0. OATS RENSION POC TO(E)1}h° 2 CW(64.5 WSFU) I CW(31.5 WSFU) HWC II / Y4"HW(8.625 WSFU) "CW(2.5 WSFU °HW(1.125 WSFU) ,)h^CW(30.375 WSFU) / 19-CW(5.75 WSFU. \ / 1 •CW(11.5 WSFU. DF / 1)h"CW(13.75 WSFU) I \ S CW �4"HW(6.375 WSFU) /'/' HW(4.875 WSFU) `\ \�`` )¢"CW(3.75 WSFU }h•HW(3.375 WSFU) �4°HW(3.375 WSFU 3 CW � PARTNER IN CHARGE "HW 1A PROJECT MANAGER ' (1.5 WSFU) UR�' SB (2.25 WSFU) ` 1T )¢"HWC(1 GPM) 1)T CW(29.25 WSFU) 1q 2A e DJ CP '"CW(5.25 WSFU %°CV1 3.00 PROJECT ENGINEER 1 1)h"CW(15.25 WSFU) L ee3 BQ MS L 1A e 1A 3.00 1}h"CW \/ }h"HW(0.75 WSFU) PROJECT TEAM MEMBERS (25.25 WSFU) WC JM ffil 2"CW(59.5 WSFU 1A 1A 1A to I WC 1A CHECK 2"CW(57.25 WSFU WC 1A 1A BQI%-CW(2 WSFU) a ENGINE! 2"CW(45.25 WSFU) I WC I WC 1 1Jq•CW(2 WSFU) 2A WA WC '� 1A OF WAsy 1A UR 1A 5� UR 1 UR 1 6/5/2023 W nnISOMETRIC RISER DIAGRAM - 1ST FLOOR RISER DIAGRAM - 1ST FLOOR 0 RISER DIAGRAMS OMEN'S AND WOMEN'S RESTROOMS OMEN'S AND WOMEN'S RESTROOMS _ P4.00 SCALE: NONE P4.00 SCALE: NONE ` PROJECT N0. G 2023-050 Q[ DATE JUNE 5,2023 W PROJECT NETWORK PATH /'� LL REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ; P4.00 H w .O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO BE U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. CITY OF ARLINGTON • 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17216 51STAVE NE Permit#: 5386 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100400100 DATE OF ISSUANCE. Scope of Work: New Plumbing for restrooms and breakroom Valuation: 95150.00 OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Bond Plumbing LLC Bond Plumbing,LLC INDUSTRIAL PARK QOZB,LLC 8201 164TH AVE NW, SUITE 110 19023 36th Ave W, Suite G 1630 215th Street SW REDMOND,WA 98052 Lynnwood Lynnwood,WA 98036 4256728281 206-779-7443 LIC:BONDPPL794MO EXP:07/29/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Bond Plumbing,LLC 1630 215th Street SW Lynnwood,WA 98036 LIC#: EXP: LIC#:BONDPPL794MO EXP:07/29/2025 JOB DESCRIPTION PERMIT TYPE: COMMERCIAL PLUMBING CODE YEAR: STORIES: 1 CONST.TYPE: 111B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 6-3v -zv2 7-M4:571� �- �f'i1,Gi G ��ih�ld� 06/23/2023 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/23/2023 Web Only-Plumbing Commercial Plan Review $940.08 06/23/2023 Credit Card Service $28.20 06/23/2023 Processing/Technology $25.00 06/23/2023 Dishwasher $15.00 06/23/2023 Drinking Fountain $15.00 06/23/2023 Floor Drain $90.00 06/23/2023 Icemaker/Refrigerator $30.00 06/23/2023 Kitchen Sink&Disposal $15.00 06/23/2023 Laundry Tray $30.00 06/23/2023 Lavatory $135.00 06/23/2023 Sink(bar,service, etc.) $15.00 06/23/2023 Toilets $150.00 06/23/2023 Urinals $75.00 06/23/2023 Water Heater(Tank) $50.00 Total Due: $1,613.28 Total Payment: $1,613.28 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5386 Permit Date: 06/06/23 Permit Type: COMMERCIAL PLUMBING Project Name: Process Solutions 2.0 Applicant Name: Bond Plumbing LLC Applicant Address: 19023 36th Ave W, Suite G Applicant, City, State, Zip: Lynnwood Contact: Bond Curtis Phone: 4256728281 Email: curtis@bondplumbing.net Scope of Work: New Plumbing for restrooms and breakroom Valuation: 95150.00 Square Feet: 108000 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: CIC Permit Issued: 06/30/2023 Permit Expires: 12/26/2023 Form Permit Type: COMMERCIAL PLUMBING Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP 31052100400100 17216 51 STAVE NE STE ARLINGTON 090 MASTER 100 AIRPORT ADDRESS INDUSTRIAL PA Contractors Contractor Primary Contact Phone Address Contractor Type License License# Bond Plumbing,LLC Curtis Bond 206-779-7443 1630 215th Street CONSTRUCTION Labor and BONDPPL794MO Sw CONTRACTOR Industries Bond Plumbing,LLC Curtis Bond 206-779-7443 1630 215th Street CONSTRUCTION COA 604 207 260 Sw CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/19/2023 C19.PLUMBING 09/20/2023 09/20/2023 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 06/09/2023 COMMERCIAL BUILDING Approved PLUMBING 06/09/2023 COMMERCIAL No comments,LT&KS PW-ADMIN-GIS Approved PLUMBING 06/09/2023 COMMERCIAL No comments.SB PW-SEW-REV Approved PLUMBING 06/09/2023 COMMERCIAL PW-WAT-REV In Review PLUMBING Fees Fee Description Notes Amount Web Only-Plumbing Commercial Plan (Table 4-1) $940.08 Review Credit Card Service $28.20 Processing/Technology $25.00 Dishwasher $15.00 Drinking Fountain $15.00 Floor Drain $90.00 Icemaker/Refrigerator $30.00 Kitchen Sink&Disposal $15.00 Laundry Tray $30.00 Lavatory Toilet&Sink Only $135.00 Sink(bar,service,etc.) $15.00 Toilets $150.00 Urinals $75.00 Water Heater(Tank) $50.00 Credit Card Service $19.35 Total $1,632.63 Attached Letters Date Letter Description 06/23/2023 Building Permit 06/06/2023 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 06/06/2023 XBP Con£ $940.08 146303787 06/06/2023 Curtis Bond 146303787 Kristin Foster $28.20 06/23/2023 XBP Conf: $645.00 147592519 06/23/2023 199973553 Brittany Harrell $19.35 Outstanding Balance $0.00 Notes Date Note Created By: 06/26/2023 Emailed that the permit is ready for issuance and can be picked up at our office. Kristin Foster 06/08/2023 Received hard copies. Kristin Foster 06/06/2023 Emailed Curtis for when he'll be dropping of the hard copy set. Kristin Foster Uploaded Files Date File Name 10/19/2023 17249105-20230623 BLD5386 ApprovedPlans.pdf 06/30/2023 16017693-20230630 BLD5386 IssuedPermit.pdf 06/06/2023 15670496-20230606 BLD5386 EquipSpecs.pdf 06/06/2023 15670497-20230606 BLD5386 App.pdf 06/06/2023 15670498-20230606 BLD5386 PlumbingPlans.pdf