Loading...
HomeMy WebLinkAbout17216 51st Ave Ne Ste 108_BLD5404_2026 r COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone (360)403-3551 This application is for new,addition,altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELETRONIC FILES and TWO (2) SETS OF CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition 43 Alteration ❑ Replaced ❑ Gas Piping Property Address: 17212 51st Ave. E Arlington, WA 98223 project Valuation: 47,000.00 Lot#: Parcel ID No.: 31052100400201 Preferred Contact: 0 Owner 0 Contractor Project Description: Addition of a ducted 4-ton split heat pump with ERV SMARTCAP ARLINGTON AIRPORT INDUSTRIAL Owner Name: Home No.: Email Address: Matt Terlau Cell No.: 937.974.0648 Mailing Address: 8201 164TH AVE NE STE City, REDMOND State: WA Zip: 98052 Contractor Name: FIVE STAR MECHANICAL Office No.: Email Address: SHANEK@FIVESTARMECH.COM Cell NO.: 206.491.1973 Mailing Address: 7509 GRANGE ST. W. City, LAKEWOOD State: WA Zip: 98499 L&I Contractor License Number: FIVESM*010JT Expiration Date: 05/01/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps(drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415. • Proper Combustion air and venting required for all appliances • A shirt-off valve is required within 6 feet of all appliances Gas Piping Specification and complete Schematic PAGE 3 Not Applicable 0 CSST O Brass O Other Proposed Piping Material: O Black Steel O Galvanized Steel Proposed Piping Size: O 1/2" O 5/8 O 3/4 1711 O 11/i" 1712 Inlet Pressure: Pressure Drop: Specific Gravity: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. ,Signed via S-1...D....... SHANE KOVALICK June 09, 2023 K,y 7f484 24 Obl 1361 d3f,42209-4 Signature Print Name Date FOR STAFF USE ONLY PERMIT# ACCEPTED BY: DATE STAMP REV2.2020 Pagel 43 MECHANICAL PERMIT FEES (per unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $75.00 = $ 0 Air Cond Unit:5 100Btu i x $15.00 = $ 0 Air Cond.Unit>10OBtu h x $25.00 = $ 0 Air Cond.Unit>50OBtuAip x $50.00 = $ 0 Air Handling Units 1 x $15.00 = $ 15 Base Mechanical Fee $25.00 $25.00 Boiler<10OBtu h>31i x $15.00 = $ 0 Boiler>1 million Btu/h<50hp x $25.00 = $ 0 Boiler>1.5 million]3tuAi<50lip x $50.00 = $ 0 Boiler>10OBtu 13-15h x $15.00 = $ 0 Boiler>50OBtu h 15-30lip x $25.00 = $ 0 Commercial Hoods-1ype I x $25.00 = $ Commercial Hoods-lype II x $50.00 = $ Diffusers x $15.00 = $ 0 Dryer Ducting x $15.00 = $ 0 Ductwork(drawings required) 1 x $25.00 = $ 2 Evaporative Coolers x $15.00 = $ Exhaust/Ventilation Fans x $15.00 = $ Fire lace Insert Stove x $15.00 = $ Forced Air Heat 15 100 Btu h x $15.00 = $ Forced Air Heat>100 Btu h x $25.00 = $ 0 Gas Clothes Dryer x $15.00 = $ 0 Gas Fired AC<_100 Btu Ai x $15.00 = $ 0 Gas Fired AC>100 Btu h x $25.00 = $ 0 Gas Fired AC> 500 BW i x $50.00 = $ 0 Gas Pi in <_ 5 units x $15.00 = $ 0 Gas Piping> 5 units(plm<5 mits x $2.00 = $ 0 Heat Exchangers x 1 $15.00 = $ 0 Heat Pump-Condensing Unit 1 x $25.00 = $ 25 Hot Water Heat Coils x $15.00 = $ 0 Miscellaneous Appliance-regulated by x $15.00 = $ 0 mechalucal code,not otherwise specified Pkg.Units<_100btu x $25.00 = $ 0 Pkg.Units>100btu x $50.00 = $ 0 Range/Cook to Gas Fired x $15.00 = $ 0 Refrigeration Unit<_10OBtt1 h x $15.00 = $ 0 Refrigeration Unit>10OBtt1 h x $25.00 = $ 0 Refrigeration.Unit>50OBtu h x $50.00 = $ 0 Re-inspection fee all x $75.00 = $ 0 Residential Range Hood x $15.00 = $ 0 Unit Heaters 15 100 Btu h x $15.00 = $ 0 Unit Heaters>100 Btu x $25.00 = $ 0 VAV Boxes(Variable Air Voltune,part of air x $10.00 _ $ 0 conditioning system) Wall Heaters-Gas Fired x $25.00 = $ 0 Water Heater- Gas Fired x $25.00 = $ 0 Permit Fee $ 90 Table 4-8; Plan Review Fee $ Processing/Tecluiology Fee $25.00 Total $ REV2.2020 Page 2 of PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated 1,EV2.2020 Pagge 3 of3 6/5/23, 10:52 AM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg3MDAmZnZpPTE3JmNOaT00Ng==&print=1 MECHANICAL COMPLIANCE SUMMA 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI Administered by:©2023 NEEA,All rights reserved Project Title Arlington Servicemaster-2018 WSEC For Building Department Use: I Date• Jun US,2U23 Project Address 17215 51 st Ave.NE Project&Applicant Arlington,WA 98223 Information Applicant Name Chris Rensch Applicant Phone 360-863-6677 Applicant Email info@renschengineering.com For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office,Other Building Cond.Floor Area 1,700 New Building Aln Project Cond.Floor Area 1,700 General Project Types Alteration or Addition Me lterati chanical Scope Single Zone Systems&Equipment Floors Above Grade 1 Mechanical Scope Compliance Method Compliance Method 1-General Mechanical Project Description ERV/DOAS installed for all ventilation.Split System ducted heat pump installed for offices and other spaces Equipment Efficiency Project Economizer DOAS Ventilation Higher Equipment Mechanical Scope Exception(s) Compliance Mechanical Compliance Type Applied? Provided? Efficiency Option Applied? Verification Scope and Method Alteration Single Zone Systems&Equipment Yes Yes NA COMPLIES Additional Efficiency Higher equipment efficiency and fan FEG Credits Included(AEC) Does building include occupancy classifications requiring DOAS? Yes Does project equipment?ro'ect include DOAS a ui ment? Yes Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR. Scope&Space Conditioning ALTERATION-SINGLE ZONE SYSTEMS&EQUIPMENT Compliance Verification F COMPLIES Single Zone Air Systems Category-Heat pump,unitary,thru-wall,SDHV Air Systems Summary Information Quantity Supply Airflow Ventilation CFM Ventilation Energy Recovery System/Equip ID of Items Control Ventilation Standard (Total if Multiple Items) Air Source Paired with DOAS Ventilation energy recovery Efficiency(%) HPI I Variable air volume I IMC Ventilation Separate DOAS ERV Yes per C403.7.6 Energy Recovery 68 Air Systems&Equipment-Cooling System/ Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance Equip ID Cooling System/Equip Type Specific Type per item(Btu/h) Multiplier Multiplier(FL&PL) Multiplier(AEC&Econo) Efficiency Units Load Efficiency Units Verification HPI Heat pump,air cooled I Split system 45,500 1 1.0 1 1 16.0 SEER I I IEER COMPLIES Air Systems&Equipment-Heating System AEC Efficiency Proposed Heat Pump HPH Proposed Low OSA LTH Efficiency Compliance /Equip ID Heating System/Equip Type Specific Type Heat Pump Heating Capacity(Btu/h) Cooling Capacity(Btu/h) Multiplier Heating Efficiency Units Temp Efficiency Units Verification HP I Heat pump,air cooled,heating I Split system 49,500 45,500 1 9.0 HSPF COP COMPLIES Air Systems&Equipment Details System/Equip ID Area(s)Served Location In Project Documents-Plan/Detail# HP Reception,Conference,Offices M2.01 System/Equip ID for a single or multiple items?:Single item Heating Section/Auxiliary Heating Type:Electric resistance(or None) Economizer Compliance Method:Applying air-side economizer exception Air-side economizer exception applied:Exp 1-WAS paired with cooling system(Note equip location limitations) WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(2)-Unitary and Applied Heat Pumps https://waenergycodes.com/print_project_Summary_form.php?k=aWQ9MTg3M DAmZnZpPTE3JmNOaT00Ng==&print=1 1/2 6/5/23, 10:52AM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg3MDAmZnZpPTE3JmN OaT00Ng==&print=1 Proposed Low OSA Temp Efficiency: I LTH Units:COP WSEC Equip Efficiency Reference Table-Heating:Table C403.3.2(2)-Unitary and Applied Heat Pumps https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg3MDAmZnZpPTE3JmNOaT00Ng==&print=1 2/2 FrDAIKI ► Submittal Data Sheet 4 Ton VRV-IV S Heat Pump Unit RXTQ48TAVJU FEATURES • Variable Refrigerant Temperature(VRT)technology allows VRV IV S series to deliver improved efficiencies and year round comfort • Improved efficiencies with SEER values up to 18.0 and HSPF values up to 10.0 - • Engineered with highly reliable Daikin Swing compressors • All inverter compressors to increase efficiency and avoid starting current DAIK/N rush — • Can provide heating down to-4°F • Added safety with optional auto changeover to auxiliary heat • Easier installation with over 60%weight reduction compared to VRV III S BENEFITS �..� • Single-phase technology enables installation in light commercial and residential applications • Broader diversity with up to 10 indoor units connectivity • Space saving compact design • Design flexibility with long piping lengths up to 984ft total and 49ft vertical separation between indoor units • Designed with reduced MOP to optimize installation costs • Backed by best in class 10-years Parts Limited Warranty and 10-years Replacement Compressor Limited Warranty* (k1STFV vjev IV Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:1/16/2017 12:32:49 PM Page 1 of 3 FrDAIKI ► Submittal Data Sheet 4 Ton VRV-IV S Heat Pump Unit RXTQ48TAVJU PERFORMANCE Outdoor Unit Model No. RXTQ48TAVJU Outdoor Unit Name: 4 Ton VRV-IV S Heat Pump Unit Type: Heat Pump Rated Cooling Conditions: Indoor(°F DB/DB):80/67 Rated Heating Conditions: Indoor(°F DB/WB):70/60 Ambient(°F DB/WB):95/75 Ambient(°F DB/WB):47/43 Rated Piping Length(ft): 25 Rated Height Difference(ft): Rated Cooling Capacity(Btu/hr): 45,500 Rated Heating Capacity(Btu/hr): 49,500 Cooling Input Power(kW): 4.85 Heating Input Power(kW): 4.00 EER(Non-Ducted/Ducted): 10.30/9.40 Heating COP(Non-Ducted/Ducted): / SEER(Non-Ducted/Ducted): 18.00/16.00 HSPF(Non-Ducted/Ducted): 10.0/9.0 Max/Min Cooling Capacity(Btu/hr): / Max/Min Heating Capacity(Btu/hr): OUTDOOR UNIT DETAILS Power Supply(V/Hz/Ph): 208-230/60/1 Compressor Type: Inverter Power Supply Connections: Capacity Control Range(%): 14-100 Min.Circuit Amps MCA(A): 29.10 Airflow Rate(H)(CFM): 2,682 Max Overcurrent Protection(MOP)(A): 35.00 Gas Pipe Connection(inch): 5/8 Max Starting Current MSC(A): Liquid Pipe Connection(inch): 3/8 Rated Load Amps RLA(A): 19.0 Sound Pressure(H)(dBA): 58 Dimensions(HxWxD)(in): 39.00 x 37.00 x 12-5/8 Sound Power Level(dBA): 76 Net Weight(lb): 176 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:1/16/2017 12:32:49 PM Page 2 of 3 FrDAIKI ► Submittal Data Sheet 4 Ton VRV-IV S Heat Pump Unit RXTQ48TAVJU SYSTEM DETAILS Refrigerant Type: R-410A Cooling Operation Range ff DB): 23-122 Holding Refrigerant Charge(lbs): 7.5 Heating Operation Range(°F WB): -4-60 Additional Charge(lb/ft): Max.Pipe Length(Vertical)(ft): 98 Pre-charge Piping(Length)(ft): Cooling Range w/Baffle(°F DB): - Max.Pipe Length(Total)(ft): 984 Heating Range w/Baffle(°F WB): Max Height Separation(Ind to Ind ft): DIMENSIONAL DRAWING m m _ ; m m N� Unit:in.(mn) Hole for anchor boll 1-3/(3 -. bolt 1/2 UNC(4 osRions(4-M12) 4-7/16 -5/1 24-7/16(620) 6-5/1 112 1-3/16(30) 60) 60) 37(940) �0 �0 4-ni �0 7 �0 �0 6 Q .QO. 3 An ; 1 5 W3--118(80) Mn ice? irn r � ' � 5 � N 3/4 `"' 2-1/16(52)19) �13 -5/8(67)i 145 y 3-1/2(89) 3/409) 5-9/16(142) e 3-9/16(90) 5/s8 1 �m N m 5 17-3/8(442) Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:1/16/2017 12:32:49 PM Page 3 of 3 "DA/K/N Submittal Data Sheet 4.0-Ton MSP Concealed Ducted Unit FXSQ48TAVJU FEATURES • Eleven capacity options from 5,800 Btu/h to 54,000 Btu/h • External static pressure up to 0.6 in.w.g.(150 Pa) • Low profile height of 9-5/8"(245 mm)for all models • 5-speed DC fan motor with selectable Auto fan speed • Ease of installation with auto adjusting airflow at commissioning based on external static pressure • Independently configurable auxiliary heat on/off temperature settings • Factory rear-return,field convertible to bottom-return • Integral condensate pump with up 25-5/16"(643 mm)of lift from the drain outlet • Drain pan inspection port • Standard Limited Warranty:10-year limited parts warranty BENEFITS • Requires as little as 11-1/4"(285 mm)of clearance above the ceiling thanks to the low profile design. • Auto fan speed control optimizes fan energy use by automatically adjusting the unit's fan speed as the room temperature approaches the set point. • The drain pan inspection port simplifies maintenance by allowing for simple and easy inspection of the drain pan conditions. �NTERrFk • Designed for quiet operation,with sound levels as low as 28 dB(A). -Vi T V C US C ISTEV Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:9/12/2018 8:56:13 AM Page 1 of 3 "DA/K/N Submittal Data Sheet 4.0-Ton MSP Concealed Ducted Unit FXSQ48TAVJU PERFORMANCE Indoor Unit Model No. FXSQ48TAVJU Indoor Unit Name: 4.0-Ton MSP Concealed Ducted Unit Type: Ducted Rated Cooling Conditions: Indoor(°F DB/WB):80/67 Ambient(°F DBMB):95175 Rated Cooling Capacity(Btu/hr): 48,000 Rated Heating Conditions: Indoor ff DB/WB):70/60 Ambient(°F DBMB):47/43 Sensible Capacity(Btu/hr): 34,300 Rated Piping Length(ft): Cooling Input Power(kW): 0.360 Rated Height Separation(ft): Rated Heating Capacity(Btu/hr): 54,000 Heating Input Power(kW): 0.36 DOO UNIT DETAILS - Power Supply(V/Hz/Ph): 208/230/60/1 Airflow Rate(H/M/L)(CFM): 1307/1,112/918 Power Supply Connections: L1,L2,G Moisture Removal(Gal/hr): Min.Circuit Amps MCA(A): 2.8 Gas Pipe Connection(inch): 5/8 Max Overcurrent Protection(MOP)(A): 15 Liquid Pipe Connection(inch): 3/8 Dimensions(HxWxD)(in): 9-5/8 x 55-1/8 x 31-1/2 Condensate Connection(inch): 1 Net Weight(lb): 104 Sound Pressure(H/M/L)(dBA): 42/39/35 Ext.Static Pressure(Rated/Max)(inWg): 0.2/0.6 Sound Power Level(dBA): 70 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:9/12/2018 8:56:13 AM Page 2 of 3 "DAIKIN Submittal Data Sheet 4.0-Ton MSP Concealed Ducted Unit FXSQ48TAVJU DIMENSIONAL DRAWING 5-1/4 f134 24-13 16 (63W 10 111 (Hanging bolt position) 8 �Q Q �a - Air Air Outlet v 0 Inlet O N 9 13 12 7 N 33-7 16 850 (From the Air Inlet) S2 3 6 5 H2 a : _ < Air Outlet J 3-9 16 (91) 7-1 16 (179) 4 7 1-15 16 (50) �n i M D H 9-11/16 245 W 55-1/8 1400 D 31-1/2 800 Air H1 8-3/16 206 Inlet W1 53-1/4(1352 Air H2 6-15/16 176 Outlet W2 1 46-15/16 1192 1 3 Drain socket 1 2 Drain hose(Accessory) 1 1 Socket(for maintenance) 0.D.01"(026) 1 0 Hanger For U10 or equivalent 9 Air Inlet flange 8 Air Outlet flange 7 Power supply wiring connection 6 Transmission and remote controller wiring connection 5 Control box(inside) 4 Ground terminal(Control box) 114 3 Drain pipe connection 0.D.0 1-1/4"(032) 2 Gas pipe connection 05/8"(015.9) Flare connection (From the Air Outlet) 1 Liquid pipe connection 03/8"(09.5) Flare connection ITEM PART NAME REMARK Note: For additional dimensional data and clearance information, refer to Engineering Data Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:9/12/2018 8:56:13 AM Page 3 of 3 fantech° a systemair company ATMOW200E Fresh Air Appliance Side duct connect ERV,201 cfm, ENERGY STAR, hanging chains Item#:463891 sP® m C US l� CErii1FlED ATMO 200E Fresh Air Appliance continuously supplies 201 cfm of fresh,filtered air while removing an equal amount of stale air.Controlled ventilation ensures home occupants receive the highest level of comfort.Up to 75%of the heat in the extract air is recovered by the energy exchanger and used to temper the fresh air coming from outside. •Side port 6"duct connection •Up to 201 cfm @ 0.4 in.wg. •Integrated air-balancing taps •Multi-speed operation •Automatic defrost •External electrical box •Lightweight •ENERGY STAR®listed ATMO 200E is designed for high static pressure applications that demand high efficiency.The product is equipped with an automatic defrost mechanism that is activated when outdoor air temperature drops to 14F(-10C)or lower.During the defrost cycle,the supply air fan shuts down while the exhaust air fan switches into high speed to maximize the effectiveness of defrost. The appliance features an efficient crossflow energy exchanger with SRE up to 75%,standard MERV3 filters,and a hanging chain kit easy connect ports,integrated air balancing taps and duct ports with plastic collar shrouds for simple and quick installation.Comes with a limited warranty(5 years on the exchanger,7 years on motors and 5 years on parts). ATMO 200E has been tested in accordance with Home Ventilating Institute(HVI)Certification Program to ensure it meets HVI ratings for airflow and energy.ENERGY STAR®listed. Note:If you are using the appliance for a simplified installation,i.e.connecting appliance's supply air duct to a furnace's return air duct,the appliance must operate continuously.In case it is turned off,the furnace will continue to draw in outdoor air directly into itself without re-heating or re-cooling.If the appliance is installed such that the homeowner may turn it off during the cold or hot seasons,we recommend installing a motorized damper ADC6 between the appliance's supply air and the furnace's return air duct that closes when the appliance is not operating. 1 NOTE:Mounting brackets(#463942)are sold separately. Technical parameters Item name:ATMOTm200E Fresh Air Appliance i Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 i Item#:463891 i Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Pagel of 9 Product Voltage(nominal) 120 V Phases 1- Input power 168 W Input current 1.4 A Air flow 200 cfm Air flow max 200 cfm Static pressure 0.4 in.wg Certificate CSA,HVI,ENERGY STAR Exchanger Heat exchanger Cross flow Dimensions and weights Weight 57.3 lb Used for Installation type Horizontal Item name:ATMOTm200E Fresh Air Appliance Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 Item#:463891 1 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 2 of 9 Performances Supply Net Consu Sensible Adjusted sensible Latent recovery/ temperat airfl med recovery recovery efficiency moisture transfer ure ow Power efficiency ea °F(°C) cfm W tin 9 32(0) (32) 52 75 81 72 32(0) (40) 58 73 78 70 32(0) 108 72 71 76 67 -13(-25) (66) 45 60 62 59 Supply Net Consu Total Adjusted total Latent recovery/ temperat airfl med recovery recovery efficiency moisture transfer ure ow Power efficiency C Gn °F(°C) Cf s) W 9 95(35) (30) 48 65 80 72 Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 Item#:463891 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 3 of 9 Dimensions m AL I'M Item name:ATMOTm200E Fresh Air Appliance Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 Item#:463891 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 4 of 9 Model A B C D Duct Size ATMO 150H 23 7/8(606) 29 1/2(750) 11 11/16(297) 21 7/16(546) 6(152) ATMO 200H 23 7/8(606) 29 1/2(750) 16 5/8(423) 21 7/16(546) 6(152) ATMO 150E 23 7/8(606) 29 1/2(750) 11 11/16(297) 21 7/16(546) 6(152) ATMO 200E 23 7/8(606) 29 1/2(750) 16 5/8(423) 21 7/16(546) 6(152) Dimensions in inches(mm) Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 I Item#:463891 1 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 5 of 9 Accessories . Contractor Commissioning Kit(463311) ECO-Feel®Auto IAQ control(414729) . ECO-Touch®Auto IAQ control(414727) RTS-W Wireless timer(414920) . COM6P Supply and Exhaust Hoods(40222) FIDT 6 Insulated Flex Duct(411064) . ADC 6 Shut-off Damper w Motor(44967) . MGE 4 Metal Exhaust Grill(411106) . MGS 4 Metal Supply Grill(411368) FID Display,Trim Kit(464000) . FID Module,Rough-in Kit(463988) Filter,MERVI3,ATMO200,Repl.kit(463946) . Filter,MERV3,Xflow,200cfm(463940) Filter,MERV8,Xflow,200cfm(463945) Documents . 463913 ATMO IOM EN FR.pdf 463955 ATMO 200E Spec Sheet.pdf CSI Specification GUIDE SPECIFICATION Specifier Notes:This guide specification is written in Construction Specifications Institute(CSI)3-Part Format in accordance with The CSI Construction Specifications Practice Guide,MasterFormat,SectionFormat,and PageFormat. Specifier Notes:This Section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the Project and local building code.Coordinate this Section with Division 01,other specification sections,and the Drawings.Delete all Specifier Notes after editing this Section. Section numbers and titles are based on MasterFormat 2016 Update. SECTION 23 72 00 AIR-TO-AIR ENERGY RECOVERY VENTILATOR Specifier Notes:This Section covers Fantech's ATMO Energy Recovery Ventilators.Consult Fantech for assistance in editing this Section as required for the Project. PARTI.GENERAL 1.1 SECTION INCLUDES A.Energy Recovery Ventilators 1.2 RELATED REQUIREMENTS Specifier Notes:Edit the following list of related sections as required for the Project.Limit the list to sections with specific information that the reader might expect to find in this Section but is specified elsewhere. A.Section 23 08 00—Commissioning of HVAC 1.3 REFERENCE STANDARDS Specifier Notes:List reference standards used elsewhere in this Section,complete with designations and titles.Delete reference standards from the following list not used in the edited Section. A.ANSI/AMCA 300—Reverberant Room Method for Sound Testing of Fans B.CSA C22.2,No.113—Fans and Ventilators C.CSA C439—Laboratory Methods of Test for Rating the Performance of Heat/Energy-Recovery Ventilators D.CSA F326—Residential Mechanical Ventilation Systems E.IEC 60529—Ingress Protection Test Standard F.ISO 9001:2015—Quality Management Systems—Requirements G.NFPA 70—National Electrical Code(NEC) H.UL723—Standard for Test for Surface Burning Characteristics of Building Materials I.UL900—Standard for Safety Air Filter Units J.UL1004—Standard for Safety Electric Motors K.UL1812—Standard for Ducted Heat Recovery Ventilators 1.4 PREINSTALLATION MEETINGS Specifier Notes:Edit the Preinstallation Meetings article as required for the Project.Delete article if not required. A.Convene preinstallation meeting[1 week][2 weeks]before start of Work of this Section B.Require attendance of parties directly affecting Work of this Section,including Contractor,Architect,installer,and manufacturer's representative C.Review the Following: a.Materials Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 I Item#:463891 1 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 6 of 9 b.Installation c.Adjusting d.Protection e.Coordination with other Work 1.5 SUBMITTALS Specifier Notes:Edit the Submittals article as required for the Project.Delete submittals not required. A.Comply with Division 01 B.Product Data:Submit manufacturer's product data,including installation instructions C.Shop Drawings:Submit manufacturer's shop drawings,including plans,elevations,sections,and details a.Wiring Diagrams:Indicate wiring for each item of equipment and interconnections between items of equipment b.Include manufacturer's names,model numbers,ratings,power requirements,equipment layout,device arrangement,complete wiring point-to-point diagrams,and conduit layouts D.Manufacturer's Certification:Submit manufacturer's certification that materials comply with specified requirements and are suitable for intended application E.Operation and Maintenance Data: a.Submit manufacturer's operation and maintenance manual;including the following: i.Operation,maintenance,adjustment,and cleaning instructions ii.Troubleshooting guide iii.Parts list iv.Electrical wiring diagrams if required b.Provide detailed information required for Owner to properly operate and maintain equipment F.Warranty Documentation:Submit manufacturer's standard warranty 1.6 QUALITY ASSURANCE A.Manufacturer's Qualifications: a.Manufacturer regularly engaged in the manufacturing of air handling units,heat,or energy recovery ventilators in the last 10 years b.ISO 9001 Certified B.Installer's Qualifications: a.Installer regularly engaged in installation of air handling units,heat,or energy recovery ventilators to that specified for a minimum of 5 years b.Use persons trained for installation of air handling units,heat or energy recovery ventilators 1.7 DELIVERY,STORAGE,AND HANDLING A.Delivery Requirements:Deliver materials to site in manufacturer's original,unopened containers,and packaging,with labels clearly identifying product name and manufacturer B.Storage and Handling Requirements: a.Store and handle materials in accordance with manufacturer's instructions b.Keep materials in manufacturer's original,unopened containers,and packaging until installation c.Store materials in clean,dry area indoors d.Keep materials from freezing e.Protect materials during storage,handling,and installation to prevent damage 1.8 WARRANTY Warranty Period:Limited lifetime on counterflow exchanger,7 years on motors,and 5 years on parts PART 2.PRODUCTS 2.1 MANUFACTURERS A.Manufacturer:Fantech Inc.,50 Kanalflakt Way,Bouctouche,New Brunswick E4S 3M5,Canada.For Canada:Toll Free 800-565-3548,CANADAsupport@fantech.net For USA:Toll Free 800-747-1762,USsupport@fantech.net Specifier Notes:Specify if substitutions will be permitted B.Substitutions:[Not permitted][Comply with Division 01] C.Single Source:Provide materials from single manufacturer 2.2 ENERGY RECOVERY VENTILATORS A.Energy Recovery Ventilators: a.Models:ATMO 150E&ATMO 200E b.Indoor,compact,residential Energy Recovery Ventilators Specifier Notes:Specify required model.Consult Fantech for assistance in determining Energy Recovery Ventilator model for the specific application. B.General a.Each Unit or Group of Units:Capable of operating in any mode independently or dependently of other systems b.Listed under CSA C22.2,No.113/UL 1812 c.Wiring:NFPA 70 d.Performance:As scheduled on the Drawings e.Equipped with a control system Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 I Item#:463891 1 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 7 of 9 f.Performs all functions necessary for operation g.Capable of changing modes with no interruption to system operation h.Capable of transferring sensible heat between the fresh and stale air streams i.Capable of operating in winter and summer conditions without imbalance or loss of ventilation capacity greater than specified in design C.Unit Cabinet a.Single Wall Cabinet: i.22-gauge galvanized corrosion resistant steel casing ii.Seams:Sealed,requiring no caulking in field b.Insulation within a Single Wall: i..75-in.(20-mm)of high-density expanded polystyrene ii.Flame Spread Index,UL 723:Not over 25 iii.Smoke Developed Index,UL 723:Not over 50 D.Cabinet Doors&Panels a.22-gauge galvanized pre-painted door b..75-in.(20-mm)of high-density expanded polystyrene E.Fans a.Factory-balanced fans with backward curved blades b.Fan Motors: i.Maintenance-free,permanently lubricated,sealed ball bearings ii.Thermal overload protected(TOP) iii.UL listed to UL1004 and/or UL2111,CSA C22.2 No.77 and No.100 iv.IP Protection,according to IEC 60529 1.Class 44 for ATMO 150E&ATMO 200E c.Separate fans for exhaust and supply blowers F.Energy recovery core a.Construction:Aluminum frame with flame rated plastic plates which are designed to transfer sensible heat.The flame spread index of the energy recovery exchanger shall not be over 25 and its smoke developed index shall not be over 50 when tested in accordance with the Standard for Tests for Surface Burning Characteristics of Building Material,UL723.The ERV Core is freeze tolerant and water washable b.Counter-flow construction type c.Frame Material:Aluminum d.Effectiveness of exchanger:Documented in accordance with ASHRAE 84 and certified to AHRI 1060 e.Flame Spread Index,energy recovery exchanger,UL 723:Not over 25 f.Smoke Developed Index,energy recovery exchanger,UL 723:Not over 50 G.Air filters a.Supply and exhaust air protected by 2 MERV-3 washable electrostatic panel type air filters b.Optional MERV-8 or MERV-13 supply air filters can be added and used along with the standard MERV-3 H.Frost prevention a.Frost prevention sequence(pre-set)initiated if the outdoor air temperature falls below the set point of 14°F(-10°C) I.Electrical 1 Phase Input Voltage a.Electrical Power:120 VAC,1 Phase,60 Hz,MOP 15A b.Internal Electrical Components: i.Factory wired for single-point power connection ii.UL Listed or Recognized and CSA Certified or Accepted where applicable and wired in compliance with the National Electrical Code J.Electrical Box Components:Accessible without stopping unit or opening doors K.Electrical Box: a.Isolated from airflow paths b.Protect integral wires and connections L.Serviceability a.Access Panel:Hinged and/or screwed access panel on front of unit b.Energy recovery exchangers,filters,and motors:serviceable from front of unit c.Fan Assemblies:mounted on removable sliding base d.Energy recovery exchangers and filters:mounted on slide-out rails 2.3 ACCESSORIES Specifier Notes:Delete accessories not required. A.Shut-off Damper:model ADC 6 B.TVOC Sensing Control:model ECO-Touch Auto IAQ C.Insulated Flex Duct:model FIDT 6 D.Plastic Supply/Exhaust Hoods:model COM61P E.Metal Supply Grill:model MGS 4 F.Metal Exhaust Grill:model MGE 4 G.Fault Indicator Display System:FID Compliance Kit(Both packages required) 2.4 ASSEMBLY Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 Item#:463891 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 8 of 9 A.Factory assembled and wired energy recovery ventilators 2.5 SOURCE QUALITY CONTROL A.Run test at factory PART 3.EXECUTION 3.1 EXAMINATION A.Examine areas to receive energy recovery ventilators B.Notify Architect of conditions that would adversely affect installation or subsequent use C.Do not begin installation until unacceptable conditions are corrected 3.2 PREPARATION A.Prepare surfaces where energy recovery ventilators are to be mounted B.Ensure surfaces are flat,level,plumb,and can support weight of energy recovery ventilators 3.3 INSTALLATION A.Install energy recovery ventilators in accordance with manufacturer's instructions at locations indicated on the Drawings B.Unit is typically hung by using metal mounting bracket supplied with unit. C.Optional chain kit available D.Install energy recovery ventilators in accordance with NFPA 70 E.Do not expose electronic components to temperatures below 32 degrees F(0 degrees C)or above 122 degrees F(50 degrees C) 3.4 ADJUSTING A.Adjust energy recovery ventilators for proper operation in accordance with manufacturer's instructions 3.5 DEMONSTRATION A.Demonstration a.Demonstrate that energy recovery ventilators function properly in every respect b.Provide hands-on demonstrations of operation of system components and complete system,including user-level program changes and function c.Provide instruction and training by factory-trained and certified representative of manufacturer 3.6 PROTECTION A.Protect installed energy recovery ventilators from damage during construction END OF SECTION Item name:ATMOTm200E Fresh Air Appliance I Product link:https://shop.fantech.net/en-US/productPermalink?p=747374 I Item#:463891 1 Document type:Product card I Created on:2023-06-121 Generated by:Fantech Online Catalogue I Language:English Page 9 of 9 ABBREVIATED SPECIFICATIONS MECHANICAL SHEET INDEX Z NOTE:NOT ALL SPECIFICATION SECTIONS MAY BE NEEDED FOR THIS PROJECT.CONTRACTOR TO APPLY SPEC.SECTIONS AS APPLICABLE TO SCOPE OF WORK. Q m m 0 0 GENERAL MECHANICAL DUCTWORK AND ACCESSORIES(CONT.) M Z M w CONTROLS AND OPERATION Sheet List Table {i CODES: DAMPERS:FURNISH AND INSTALL(F&I)DAMPERS IN ACCORDANCE WITH THE k PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT MECHANICAL CODE, FOLLOWING TYPES AND FUNCTIONS: Sheet Number Sheet Title Q W STATE AND LOCAL CODES/ORDINANCES AND AHJ.ALL WORK SHALL ALSO BE THE MECHANICAL CONTRACTOR SHALL F&I ALL CONTROL WIRING NECESSARY FOR J S IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. •BALANCING DAMPERS:SINGLE BLADE LOCKABLE MANUAL SETTING OR ON THE COMPLETE SYSTEM INCLUDING ALL MODES OF OPERATION AND INTERLOCKS. M0.01 MECHANICAL SPECIFICATIONS THE MECHANICAL CONTRACTOR SHALL COORDINATE MECHANICAL WORK WITH LARGER DUCTS,MULTI-BLADE RECTANGULAR WITH LOCKABLE MANUAL M0.11 MECHANICAL ENERGY FORMS coOTHER TRADES.THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE SETTING. SEE PLANS FOR FURTHER CONTROL REQUIREMENTS. OVER ALL OTHER DRAWINGS.DO NOT SCALE DISTANCES OFF THE MECHANICAL •ISOLATION DAMPERS IN ROUND DUCTS:SINGLE BLADE TYPE J HVAC UNIT(S)TEMPERATURE CONTROLS M2.01 MECHANICAL HVAC PLAN _ DRAWINGS;USE ACTUAL BUILDING DIMENSIONS. •ISOLATION DAMPERS IN RECTANGULAR DUCTS:PARALLEL MULTI-BLADE Q TYPE STANDARDS:EQUIPMENT AND MATERIALS SHALL CONFORM WITH •ZON CONTROL DAMPERS IN ROUND DUCTS:SINGLE ROUND BLADE PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT M5.01 MECHANICAL DETAILS V APPROPRIATE PROVISIONS OF ARL,ASME,ASTM,UL,NEMA,ANSI,SMACNA, •CONTROL DAMPERS IN RECTANGULAR DUCTS:OPPOSED MULTI-BLADE M6.01 MECHANICAL SCHEDULES Z H ASHRAE,NFPA,OTHER APPLICABLE AGENCIES AND AHJ,AS APPLICABLE TO TYPE 1. FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING THE SPACE EACH INDIVIDUAL UNIT OR ASSEMBLY. V ISOLATION DAMPER AIR LEAKAGE:DAMPER SHALL BE OF CLASS I LEAKAGE TEMPERATURE CONTROLLER(THERMOSTAT OR SENSOR) w W SITE EXAMINATION:THE MECHANICAL CONTRACTOR SHALL THOROUGHLY SPECIFICATION AS PER IMC 2018 AND WSEC 2018 2.THE HEAT PUMP THERMOSTAT IS SHOWN ON THE DRAWINGS IN A RECOMMENDED J EXAMINE ALL AREAS WHERE EQUIPMENT,DUCTWORK AND PIPING WILL BE LOCATION.COORDINATE WITH THE TENANT OR OWNER,IF THE LOCATION W INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER INDICATED IS NOT SUITABLE DUE TO FURNISHINGS,APPLIANCES,OR Q o INSTALLATION OF THE MECHANICAL WORK. GRILLES,REGISTERS&DIFFUSERS:GRILLES,REGISTERS AND DIFFUSERS APPURTENANCES.VERIFY WITH THE ENGINEER OF RECORD THAT THE PROPOSED SHALL BE AS SCHEDULED AND SHALL BE FURNISHED AND INSTALLED BY THE ALTERNATE LOCATION IS ACCEPTABLE. I Q o MECHANICAL CONTRACTOR.DIFFUSERS SHALL BE INSTALLED AS INDICATED ON 3.PROGRAM THE THERMOSTAT IN ACCORDANCE WITH THE 2018 WASHINGTON f' w m HVAC EQUIPMENT&MATERIALS THE DRAWINGS AND SCHEDULES.THE MECHANICAL CONTRACTOR SHALL STATE ENERGY CODE SECTION C403.4 PROVIDING TIME OF DAY AND WEEKLY MECHANICAL LEGEND �+ J a PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND OCCUPANCY SCHEDULES,NIGHT SETBACK CAPABILITY(55-F FOR HEATING AND Q 3 HVAC UNITS:UNITS SHALL BE AS SPECIFIED IN PLANS AND SHALL BE PROPER INSTALLATION IN THE TYPE OF WALLS USED IN THIS PROJECT. 85-F FOR COOLING),5 DEGREE DEADBAND BETWEEN HEATING AND COOLING C> FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR.THE SETPOINTS,MAXIMUM OF 2-HOUR MANUAL OVERRIDE,AUTOMATIC START AND 7 N 3 MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THERMAL INSULATION:PROVIDE EXTERNAL THERMAL INSULATION WITH AN STOP FUNCTION THAT REDUCES THE HEATING SETPOINT AND INCREASES THE NOTE:NOT ALL SYMBOLS MAY BE USED IN THESE DRAWINGS. ` Z L _LA DELIVERY,PROVIDING COMPLETE INSTALLATION INCLUDING CURBS,PIPES, INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL, COOLING SETPOINT BASED ON THERMAL LAG AND ACCEPTABLE DRIFT FOR A ` a yj 2 VIBRATION ISOLATON AND NECESSARY ACCESSORIES,AS WELL AS PROVIDING STATE ENERGY CODE AND A.H.J.REQUIREMENTS.PROVIDE INSULATION ON PERIOD OF 30 MINUTES BEFORE SCHEDULED UNOCCUPANCY. W = > O WARRANTY. EXHAUST AND OUTSIDE AIR DUCTS AND ON CONCEALED PORTIONS OF SUPPLY (,� Q I AND RETURN AIR DUCTS.DO NOT INSULATE EXPOSED DUCTWORK WITHIN THE 4.TO PROVIDE BOTH OCCUPIED SETPOINT AS WELL AS NIGHT SET-BACK(OR W p EXHAUST FANS&ERVS:UNITS SHALL BE AS SPECIFIED IN PLANS AND SHALL BE SPACE AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED.THERMAL UNOCCUPIED)FUNCTION WHEN THE FACILITY IS NOT OCCUPIED. I X TYP.SUPPLY DUCT UP/DN Z FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR.THE INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS AND 5.THE UNIT FAN SHALL BE PROGRAMMED AT THE THERMOSTAT TO RUN AS ON UP NJ DUCT HEATER N MECHANICAL IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH SMOKE DEVELOPED NO GREATER THAN 50. FOLLOWS:NEW AND EXISTING VENTS AND INTAKES,PROVIDING COMPLETE INSTALLATION n z TYP.RETURN DUCT UP/DN MANUAL VOLUME DAMPER INCLUDING DUCTWORK TO UNIT AND NECESSARY ACCESSORIES AND ACOUSTIC DUCT LINER:UNLESS OTHERWISE INDICATED ON THE PLANS,F&I 1" • CALLS FOR HEATING OR COOLING;MAXIMUM SPEED BASED ON CFMS INDICATED. DN UP o BACK DRAFT DAMPER PROVIDING WARRANTY. GLASS FIBERACOUSTICAL DUCT LINER ONSUPPLY AND RETURN DUCTWORK �� �J� m WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. • OCCUPIED(NON HEATING OR COOLING);SET AT LOW SPEED I l: I.0 I TYP.EXHAUST DUCT UP/DN m BAROMETRIC DAMPER DUCTWORK AND ACCESSORIES INCREASE DUCT SIZED INDICATED ON PLANS 2"IN EACH DIMENSION TO UNOCCUPIED;CYCLES WITH HEATING/COOLING FUNCTIONS L 'J ILL ACCOMMODATE LINER.LINER SHALL BE FASTENED TO DUCT WITH MECHANICAL I� m DUCT SMOKE DETECTOR SHEETMETAL DUCTWORK:ALL DUCTWORK SHALL BE RIGID SHEETMETAL LINER FASTENERS IN ACCORDANCE WITH SMACNA. I r!I TURNING VANES CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH I� MOTORIZED DAMPER &allft C. SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS.FIBERGLASS TESTING,ADJUSTING,AND BALANCING DOAS/ERV UNITS pf a DUCTBOARD IS NOT ALLOWED.ALL EXPOSED DUCTWORK SHALL BE ROUND, OT THERMOSTAT COMBINATION SMOKE AND FIRE SPIRAL OR RECTANGULAR LOCK-SEAM TYPE,AS SHOWN ON HVAC PLAN. MECHANICAL CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS 1. DOAS UNIT INCLUDES AFACTORY-PROVIDED CONTROLLER AS A USER DAMPER ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED TO PROVIDE AIR QUANTITIES TO ALL ZONES AS INDICATED ON THE DRAWINGS INTERFACE.THE CONTROLLER SHALL BE CAPABLE OF SETTING TIME OF DAY AND INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT(5%LEAKAGE)AND NOISELESS AND IN THIS SPECIFICATION.THIS SHALL INCLUDE BALANCING AIR FLOWS AT WEEKLY OCCUPANCY SCHEDULES.IN ACCORDANCE WITH WSEC 2018.THIS OS SENSOR SPIN-INTAKE-OFF AND VOLUME IN OBJECTIONABLE NOISE)SYSTEMS,CAPABLE OF PERFORMING EACH DISCHARGE AND INTAKE TERMINALS AS WELL AS BALANCING FAN SYSTEMS. TIMING CONTROL MAY ALSO BE INTEGRATED INTO THE AIR HANDLER DAMPER ' 304 INDICATED SERVICE.FURNISH ALL REQUIRED DAMPERS,TRANSITIONS, BALANCING FAN SYSTEMS WILL REQUIRE(ATA MINIMUM)THE MEASURING AND THERMOSTAT CONTROL IF THERE IS A VENTILATION AUXILIARY CONTACT. orsTeae9 CONNECTIONS TO AIR TERMINALS AND OTHER ACCESSORIES NECESSARY FOR ADJUSTING OF THE FOLLOWING PARAMETERS: SUPPLY AIR ARROW SSJpNALgryp A COMPLETE OPERATING SYSTEM.NO VARIATION OF DUCT CONFIGURATION OR o-> UNDERCUT DOOR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. •SUPPLY AND RETURN STATIC PRESSURES RETURN AIR ARROW •DRIVE RPM'S ELECTRIC WALL HEATERS FLEXIBLE DUCTWORK:FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS •TEMPERATURE DIFFERENTIALS(HEATING AND COOLING SHOWN IN PLAN.FLEXIBLE DUCTWORK SHALL BE PULLED TAUT AND 1. ELECTRIC WALL HEATERS SHALL BE INSTALLED WITH A FACTORY MOUNTED APPROPRIATELY FASTENED TO RIGID BRANCH DUCT&DIFFUSER.BENDS SHALL WHERE QUANTITIES ARE NOT INDICATED BALANCE PER INDUSTRY STANDARD INTEGRAL THERMOSTAT SET AT 55°F. BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND.SUPPORT BANDS TO PROVIDE A PROPERLY WORKING SYSTEM.OPERATE AUTOMATIC CONTROLS 12 X 8 SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT.FLEXIBLE DUCTWORK SYSTEM AND VERIFY SET POINTS. INDICATES UNLINED 12"z 8"O.D.SHEETMETAL SHALL BE UL 181 LISTED AS A CLASS 1 AIR DUCT. (1ST FIGURE=SIDE SHOWN DUCTSEALANT:SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A SYSTEM COMMISSIONING 2ND FIGURE SIDE NOT SHOWN) NON-HARDENING,NON-MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND NOT REQUIRED SEAMS IN SHEET METAL DUCTWORK.COVER ALL FIELD JOINTS,JOINTS AROUND SPIN-IN FITTINGS AND FASTENING SCREWS WITH MASTIC. IIIIIIIIIIIIIIIIIIIIII SUPPORTS:PROVIDE HOT-DIPPED GALVANIZED STEEL,FASTENERS,ANCHORS, FLEXIBLE DUCT RODS,STRAPS,TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. 1/ XX—X DIFFUSER SIZE LU XXXX DESIGN CFM(WHERE APPLICABLE)CFM SHOWN FOR RETURN ARE UNOCCUPIED MODE (n a GENERAL NOTES O CEILING DIFFUSER(FLOW ARROWS SHOWN W O INDICATE DIRECTION OF AIR FLOWS) zU 1. ALL IS NEW UNLESS OTHERWISE NOTED. EJ E� CEILING RETURN/EXHAUST GRILLE W 2. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS,FLOORS,CEILINGS > LL OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED O Lij DURING THE COURSE OF WORK. M3.0 DETAIL MARK d 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR Z ARRANGEMENT OF SYSTEM(S).FOLLOW DRAWINGS IN LAYING OUT WORK AND F CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE CONDITIONS.MAINTAIN DETAIL MARK Z HEADROOM AND SPACE CONDITION. MX.X Z 0 w N SHEET WHERE DETAIL IS SHOWN LU Z Q 4, ALL NEW HVAC DUCTWORK AND EQUIPMENT SHALL BE SUPPORTED FROM THE LU .3 STRUCTURAL CEILING OR PLATFORM(CONFIRM). 5. NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED WHERE IT XXXXX EQUIPMENT MARK-SEE SCHEDULE U d Z w O OBSTRUCTS ANY EXISTING AREAS THAT REQUIRE ACCESS(e.g.FIRE/SMOKE LU ACCESS PANELS,VALVES,ETC.). O m a 0 Q �a REVISIONS MECHANICAL ABBREVIATIONS A ABOVE FINISHED FLOOR MAX MAXIMUM AHJ AUTHORITIES HAVING MECH MECHANICAL JURISDICTION MC MECHANICAL CONTRACTOR AHU AIR HANDLING UNIT MEP MECHANICAL,ELECTRICAL APPROX APPROXIMATE AND PLUMBING MFG MANUFACTURER BLDG BUILDING MIN MINIMUM MOF MAKE ON FALL(THERMOSTAT) C CONDENSATE PIPING MOR MAKE ON RISE(THERMOSTAT) CLG CEILING CONST CONSTRUCTION "NC" NORMALLY CLOSED(CONTACT) CD CEILING DIFFUSER "NO" NORMALLY OPEN(CONTACT) PROJECT SUMMARY NTS NOT TO SCALE DEG DEGREES A NEW SHELL BUILDING SPACE SHALL BE REMODELED TO SERVE AS A NEW OFFICE DTL DETAIL OSA OUTSIDE AIR SPACE WITHIN A LARGE EXISTING WAREHOUSE.THE HVAC SYSTEM SHALL BE A SPLIT DN DOWN SHEET TITLE SYSTEM HEAT PUMP WITH DUCTED AIR HANDLER.A DOAS SYSTEM WITH ERV SHALL DOAS DEDICATED OUTSIDE AIR SYSTEM PM PROJECT MANAGER B DWG(S) DRAWING(S) PROVIDE THE OFFICE SPACE VENTILATION NEEDS,EXHAUSTING FROM THE OFFICE MECHANICAL REF REFERENCE RESTROOM AND BREAKROOM AND DELIVERING FRESH AIR TO EACH SPACE IN THE EA EACH REQ('D) REQUIRE(D) NEW OFFICE.THE EXISTING WAREHOUSE SYSTEM GAS HEATER(S)WILL REMAIN SPECIFICATIONS C EC ELECTRICAL CONTRACTOR REV REVISED/REVISION UNCHANGED. ELEC ELECTRICAL RG RETURN GRILLE EF EXHAUST FAN RL REFRIGERATION LIQUID LINE EM EMERGENCY RS REFRGERATON SUCTION LINE (E)OR(EX)EXISTING EXT EXTERIOR BHT SHEET EG EXHAUST GRILLE SPECS SPECIFICATION(S) EWH ELECTRIC WALL HEATER SF SQUARE FEET F&I FURNISH 81NSTALL SS STAINLESS STEEL Permit Set FLR FLOOR TEMP TEMPORARY FT FOOT/FEET TYP TYPICAL GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE HP HEAT PUMP WH WATERHEATERDESIGNER H.E HR HOUR CHECKED BY CHRIS RENSCH HVAC HEATING VENTILATING&AIR CONDITIONING SHEET LL LANDLORD LV LOW VOLTAGE M 0.O 1 n N LOAD CALCULATIONS WSEC 2018 ENERGY CODE Z W M MATRIX a M M Z U In MOTOR EFFICIENCY FAN MOTORS NOT COVERED BY TABLE N05.8(3)AND C405.8N)SHALL BE ELECTRONICALLY W 0 E - (FRACTIONAL-1112 HP- COMM UFATED(EC)OR SHALL HAVE A MINIMUM MOTOR EFFICIENCY OF 70%WHEN RATED IN O DESCRIPTION NOTES 1 HP) ACCORDANCE WITH DOE 10 CFR 431. n HEATING AND COOLING LOAD CALCULATIONS HAVE BEEN COMPLETED IN COMPLIANCE WITH THE Ib S stem Checksums SIZING REQUIREMENTS ENERGY CODE AND THE RESULTS ARE INCLUDED WITHIN THESE PLANS UNITS HAVE BEEN SIZED TO VENTILATION MINIMUM VENTILATION IS SET AT NO MORE THAN 150%OF DESIGN REQUIREMENTS AS DEFINED BY THE J Y MECHANICAL CODE. By RENSCH ENGINEERING THE MINIMUM AVAILABLE OUTPUT CAPACITIES PROVIDED BY THE MANUFACTURER. Q UNIT 1 Incremental Heat Pump WAC PIPE INSULATION INSULATE ALL REFRIGERANT PIPING PER TABLE C403.2.9. THERMOSTATS ZONE THERMOSTATIC CONTROLS ARE PROVIDED WITH A TEMPERATURE RANGE OR DEADBANU OF AT COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES LEAST 5YF WHERE USED FOR BOTH COOLING AND HEATER SETPOINT[S.(SEE THERMOSTAT NOTES) Peaked al Tine: MolHc 7/1fi Mohr.Surn of MWHr.Heafin Oesi n Co011 Hesan FAN AIRFLOW FAN MOTORS NOT COVERED BY TABLE C405.8(3)AND C405SN)SHALL BE ELECTRONICALLY 7 g 9 n9 9 COMMUTATED(EC)OR SHALL HAVE A MINIMUM MOTOR EFFICIENCY OF 70%WHEN RATED IN ` („) 0II,MI Alr: OADWWWHR:821fi41fi1 OAUH:Peals 01 24 SADB 560 805 EACH ZONE SHALL BE PROVIDED WITH THERMOSTATIC SETBACK CONTROLS THAT ARE CONTROLLED BV EFFICIENCY ACCORDANCE WITH DOE 10 CFR431. W R.Plenum 73.7 ]00 EITHER AN AUTOMATIC TIME CLOCK OR PROGRAMMABLE CONTROL SYSTEM.SETBACK CONTROLS THERMOSTAT SETBACK J Space Plenum N.Percent Space Percent Space Peek Coil Peak Percen[ Return 72.0 70.0 SHALL HAVE THE CAPABILITY TO SETBACK OR TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE DEDICATED OUTDOOR DOAS SHALL BE PROVIDED FOR OFFICE SPACES W Sena.•Tat Sens.•Let Tat"0111, Sensible Of Ttal Space Sens Tot Sens Of Total RI 725 678 TEMPERATURES DOWN TO 55°F OR UP TO 85°F.(SEE THERMOSTAT NOTES). AIR SYSTEMS POAS) B1ulh 61Wh BIugI (Y.F BIWh (%) BWlh &ulh IXI Fn BIdTD 00 00 ENERGY RECOVERY DOASSHALL INCLUDE ENERGY RECOVERY VENTILATION THAT COMPLIES WITH THE MINIMUM ENERGY 0 O Envelope Loads Envelope Loada Fn Rid 0.1 00 AUTOMATIC START AUTOMATIC START CONTROLS SHALL BE PROVIDED FOR EACH HVAC SYSTEM.THE CONTROLS SHALL VENTILATION WITH IDEAS RECOVERY EFFICIENCY AND ENERGY RECOVERY BYPASS REQUIREMENTS. Z 7 fh Skyll[e Solar 0 0 0 0 0 0 Sky Solar 0 0 0.00 F.Fri[1 0 3 00 CONTROLS BE CAPABLE OF AUTOMATICALLY ADJUSTING THE DAILY START TIME OF THE HVAC SYSTEM IN ORDER O N Skylhe Cand 0 0 0 0 0 0 Skyli[e Cord 0 0 0.00 a r- W Roof Cond 0 0 0 0 0 0 Roof Cord a 0 0 00 (OPTIMUM/MORNING TO BRING EACH SPACE TO THE DESIRED OCCUPIED TEMPERATURE IMMEDIATELY PRIOR TO HEATNG/COOLING 01 Glass Solar 6,fi18 0 6,618 21 T 446 26 Glass Solar 0 0 1,m AIRFLOWS STARTUP) SCHEDULED OCCUPANCY. SYSTEM FAN CONTROLS EXCEPTION:PRIMARY SUPPLY FAN MY RUN AT LOW SPEED PROVIDED IT USES NO MORE THAN 0.12 J W GlasslDC.,Cond 1266 0 1.2. 4 1,122 4 Glass'Daor Cond -6,426 b,426 27.53 !:Doling Heating WICFM Q ? 3 Wall Cond 402 6 408 1 683 3 Wall Cond -665 -679 291 DCV DEMAND CONTROL VENTILATION IS NOT PROVIDED SINCE LESS THAN 750 CFM P.did"Door 2,826 2,02fi 9 2,826 11 Padl-ID-Ir -7.064 -7.064 30.26 Diffuser 1 fi67 1 6G7 MECHANICAL MECHANICAL COMMISSIONING IS NOT REQUIRED SINCE SYSTEM CAPACIW IS NOTABOVE 240MBH M = Floor 0 C 0 ON 0 Floor -1506 -1506 646 Terrrrinel 1667 1,667 COMMISSIONING COOLING. Z V N Adjnr:enl Fluor ON ON 0m 000 05w 000 Adjacent F"" 000 000 0, main Fan 1,867 1,Fi67 ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER THE INTERNATIONAL MECHANICAL CODE In6laafi- 760 7. 2 521 2 In611ratian -3.581 -3.681 15.34 Sec Fan 0 C OMC),WASHINGTON STATE ENERGY CODE C402 LEAKAGE REQUIREMENTS AND INTERNATIONAL a LLI Sub Totaf=_> 17,872 6 77,078 37 12,198 46 Sub Tofaf==s -19242 -19,255 82 48 NoIn Vent 202 202 DUCNJORK BUILDING CODE(IBC)VAPOR RETARDER REQUIREMENTS.IF SPECIFICATIONS FOR DUCT CONSTRUCTION W = > 0 AT Vent 202 202 AND LEAKAGE REQUIREMENTS ON PLANS ARE MORE STRINGENT THAN CORRESPONDING CODE THE FOLLOWING SHALL BE PROVIDED TO THE BUILDING OWNER OR OWNER'S AUTHORIZED AGENT IJ Q I hen-!Load. I.I.m"Lo.6 [Oil 71 71 REQUIREMENTS,SPECIFICATIONS ON PLANS SHALL BE ADHERED TO. WITHIN 180 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY'. LU 0 Lights 3,214 804 4,018 13 3,214 12 Lights 0 0 0.00 MInStDPIRh C ❑ RECORDDOCUMENS(CONSTRUCTONDOCUMENSUPDATEDTO ' N People 9,319 0 9,319 29 5,399 20 PIC 0 0 0 00 Retum 1.737 1.131 BUILDING CONVEY RECORD OF COMPLETED WORK) Misc 5,022 0 5.022 16 5,022 19 Misc 0 0 0.00 Eah...t 27"J 272 LOW-PRESSURE DUCT ALL DUCTWORK SHALL BE OF THE TYPE:"LOW-PRESSURE DUCT SYSTEMS",STATIC PRESSURE NOT TO DOCUMENTATIONAND MANUALS(OPERATING AND MAINTENANCE MANUAL FOR EACH Sob Tea,=� 17,555 SM 18.359 57 13,635 51 Sob Total==� 0 0 0.00 Rm Eah C 0 SYSTEMS EXCEED 2 IN.W.G. CLOSEOUTSUBMITTAL PIECE OF EQUIPMENT REQUIRED TO BE COMMISSIONED BY THE Auxiliary 0 0 REQUIREMENTS ENERGY CODE. Ceiling Load 009 A09 0 0 811 3 Ceiling Load -13 0 0.00 Ldkage DW. 0 0 COMPLIANCE DOCUMENTATION(ALL ENERGY CODE COMPLIANCE V-N lion Load 0 0 958 3 0 0 Va.Hall-Teed 0 d,089 1752 Leakage Up. 0 0 FAN AIRFLOW CONTROL N/A-ALL SYSTEMS ARE LESS THAN 85 MBH. FORMS AND CALCULATONS) SEAT Adj Air Trans Heat 0 0 0 0 0 Adj Ak Trans Heat 0 0 0 SEE C103.6 OF THE CURRENTWSEC FOR A COMPLETE DESCRIPTION OF WHAT IS REQUIRED. Dehumid.Ov Sizing 0 0 Or/Undr sizing 0 D 0.00 DUCT INSULATION: AIR DUCTS SHALL BE INSULATED AS STATED ELSEWHERE AND PER THE FOLLOWING: 13wundr sain9 D ❑ ❑ ❑ ❑E[naaat Heat ❑ o Do ENGINEERING CKS Exhaust Heat 0 0 0 GA Preheat DiH. 0 0 DO SUPPLY AND RETURN OUTSIDE BUILDING-RB MIN UNCONDITIONED SPACE-R6 MIN Sup.Fan Heat 790 2 RA Preheat DiN. 0 O.DO C-ling Heating AIR/PLENUMS SUPPLY DUCTS 005°F<AIR TEMP<55-F)WITHIN CONDITIONED SPACE-R3.3 MIN !so C. Ret.Fan Heat 0 0 0 Addtlonal Reheat 0 000 'A DA 12.1 72-1 O?W Duet Heat Pkup 0 0 0 elm/ke 1.13 1.13 Hndaf!Sop Ht Pkup 0 0 Undedlr sup Ht Pkup 0 0.00 o0nkon 568.47 ECONOMIZER 9.DEDICATED OUTDOOR AIR SYSTEMS THAT INCLUDE ENERGY RECOVERY AS REQUIRED BY SECTION supply Air Leakage 0 0 ❑ soppy Ai Leakage 0 0 W N.A.. 501 96 EXCEPTIONS C403.7.6 BUT THAT DO NOT INCLUDE MECHANICAL COOLING. 8lulhrfN 2391 -2a 79 M sz AM we gyc es_c p p I _ ry_orm.pnp?k=awOgMTg3MOAmznivFTF3�mIg0aTaarvg=aprinH=1 G nd Total=a 30,237 0 31986 100 U0 26644 10000 Grand Tole)=a -19.255 -23,344 10000 No.Peapk; 22 encr o om�n ro ee:em K CLASS I(LEAKAGE LESS THAN 4 CFM/FT-2(d 1"W.G.IN ACCORDANCE WITH AMCA 500D) ME }, 304� COOLING COIL SELECTION AREAS HEATING COIL SELECTION REQUIRED ON: - s or O Total Capacittyy Sens Cayy.Coil Airf..".,DB4W61HR Leave DBAMBIHR Gross TDtal Glass Capacity[ (Airflow Enl Lvg OUTDOOR AIR SUPPLY/RETURN AIR OPENINGS USED FOR AIRSIDE ECONOMIZER sec c®q�.r�rec�e<BJa:reiog igmamgow,p�,aaaaa,.e5=renm4,u Rr uemq.o±pzs Assgw.;rp-.gym SZpArALQtl ton MBh Mf3h dm °F `F gr4b °F T grdb III (%) MBh of din T °F EJ]HAUST OPENINGS eeTe<r nu= en�am,sm;= -xaxaw ea<e,vm.x><pdonunv.=: (Date: San05,2023 Main clg 2.9 35.2 30.7 1,667 72.9 60.4 59.6 56.0 53.0 55.9 Floor 1,471 ain Htg -36.5 1,667 54.6 80.5 RELIEF OUTLETS Aux Cl g 00 0.0 0.0 D 0.0 0.0 0.0 0.0 0.0 00 Part 2,834 .Htg 0.0 0 0.0 0.0 Opt yen 0.0 0.0 0.0 0 0.0 OD O.0 OA 0.0 0.0 ht Door 1 reheat 0.0 0 0.0 0.0 "MOTORIZED DAMPERS ary wrn,� E[Flr 61 EXCEPTION:MOTORIZED DAMPERS WITHIN UNITARY PACKAGED EQUIPMENT MUST HAVE MINIMUM .yea.awxm,aa..eae�e.a. Tot.! 29 352 Root 0 0 0 Midfl 00 0 00 00 LEAKAGE AVAILABLE FROM MANUFACTURER mv.Js,pp.mes.asxsaope. =�a=emp�aV:�,=asKma=� Wall 605 290 48 pt Vent 0.0 0 0.0 0.0 Est Uom 0 0 0 T.G1 -36.5 ®a.;A euiraoe rw.J�u DAMPERS SHALL CLOSE WHEN SYSTEMS SERVED BY DAMPER ARE NOT IN USE,DURINGMORNING pmr.cltm6 Em4�;m U c®p;ffieanma5-caw Project Name: TRACE®709 v6.3.5 nlcvlated at 10:30AM on Ofil05/2023 WARM UP,AND SETBACK OPERATION NLESS REQUIRED OTHERWISE BY CODE e>v.-I e.J.nm..Ipane wuaee.sq;,sn��mrm��'ra�ree�n me^roRema== Dataset Name: Arlington SeRicemaaterlrc Allemallve-1 Sy.tem Checksuma Reporl Pagel oil �� � �Emaom� rydpm rErca' M�,oJ,lxsme�== [ryp. M.d�olsra= Emra°.[J arWr[vwa•.r cmea.m aocv s.e...da4•• wrnru+ ram➢OPa®APprtit 5�rwiwmmiS9�ua ^4=af�Ol ,=.num+=[�nae,=reemom .u�.r=gJns �a ri��--e=e.,rsen Kr�nmdr„ �e�.xnnw®dao.=aro.a,�®®a�ewnyr..e.�w^.s LJ_ LU Seape a:Sprx[aedltloamg ALTERA'r40N-SEgCLE ZDNE 6Y6'rEMS&EQ1I@InEN'I' -mpnenre VeMcalba [nMPI.¢�5 CONTROLS MATRIX `^a� �`°.hr n`p^� Q %r.�rrgWv Q,mn .uenh,l.m (Nrvlm IW6ple aonq axy(a0 wv�.aeq�m.,,-�� I=w wume we emw1 m5 Nb � U oosne sasvmrEquip T'ce speri.e Type Qeeu.r e.w.ey ae[a.:, ue.°E...pava ^me®ea[a��r r„ww c°°mr ee nrepe�e.n a a®mww n[mee..=re M.weve=p'I.arI.I M�tiw y.ca e=o,o) z MECHANICAL CONTROL SUMMARY W > FAN SCHEDULING aN�aE r 4s sso r xp nmr Fs � 0-1 ULI PROGRAMMAB OCCUPIED- REMOTE rw swrrw a®r nu,p w,nm¢c.wenma4[T u°uoe uwarmr,xnl'r c"^'H""" VENTILATION LE UNOCCUPIED 111 UNIT/SYSTE SYSTEM CONTROL WIRING HEATING? MORNING TOTAL AIRFLOW DCV EDGING OCCUPIED FAN INTERLOCKS ISOLATION spsr=� O LIJ MEASERVED CONTROLTYPE COOLING?TYPE? AIRFLOW THERMOSTAT FAN CYCLING NOTES '^ MIT DESCRIPTION SPECIFICATION BY? TYPE? WARM-UP CONTROL CONTROL CONTROL CONTINUO CYCLING 0AITH? DAMPER VJ CONTROL OR SPACE WITH HTG �= d US FAN NTH HTG S INTERLOCK? MJ=>s= TEMPERATURE CLG ONLY In - saw.>�mr rw �[^.na.> Nz ol ®wmc^=es�m°w^naaNr^s.v.,a.2®a.a.aoes® Z r+x CONSTANT STANDARDELECTRONIC YES,DX CONSTANT - maro wi.m a;m=m;,e a»em(N,e yr l .sEcagwpem.;mne=remarnm rms,a rwe Om332lp vmnnmdnppti=eemwmw Z O N SINGLE ZONE. YES,HEAT PUMP FANOCCUPANCV Wp°oj HP/FCU VOLUME PROGRAMMABLE �PELECTRONIC ROGRAMMABLE MC SUPPLVAIR X ERV UNIT(ERV-1) -- X NA NOTE1 X X -- -- ps p pq ry g=pn t trz MULTIPLE SPACES (HP) SCHEDULING(FCU) Mecotl COfN - - paT wOalnT4+MOoawrzpvTE W /�'1 Z Q SYSTEM THERMOSTAT THERMOSTAT TEIPERATURE F v ;3 W Z ¢Z SUPPLY EXHAUST U d Mir TO PROVIDE 24 VAC ISOLATION DAMPER J FACTORY PROVIDED FAN TECH FANS RUN FAN TECH ENERGY W } ER-1 RECOVERY ALL SPACES MC -- -- -- -- X -- X -- -- -- X ACTUATORS FOR BOTH SUPPLY AND EXHAUST VENTI CONTROL PANEL CONTROLLER CONTINUOUSLY DURING CONTROLLER m N rpZ LATOR TERMINATIONS. LL OCCUPANCY O a Q �a NOTE:1.SET 2 SPEED SUPPLY FAN CONTROL.SEE N0.01 FOR ADDIDTIONAL INFORMATION. REVISIONS VENTILATION CALCULATIONS MECHANICAL VENTILATION CALCULATION TYPE OF OCCUPANTS TOTAL SELECTED CFM PER CODE EZ TOTALREQ'D DESIGNVEN SPACE SQ.FT. SPACE PER1000SF OCCUPANTS OCCUPANCY PERSON CFM/SQ.FT. FACTOR VENTCFM CFM Open Office 620 Office Spaces 5 3 6 5 0.06 1 67 70 Office 106 120 Office Spaces 5 1 1 5 0.06 1 12 15 Office 107 120 Office Spaces 5 1 1 5 0.06 1 12 15 Reception 190 Reception area 30 6 3 5 0.06 1 26 30SHEET TITLE Conference 190 Conference Room 50 10 10 5 0.06 1 61 65 MECHANICAL 1,240 179 195 ENERGY FORMS Permit Set CHECKED BY CHRIS RENSCH SHEET M0. 11 GENERAL NOTES ® KEY NOTES (5 M 1. COORDINATE WITH ELECTRICAL 6.LOCATE HEAT PUMP AT ROOF LEVEL,10 FEET N M M CONTRACTOR FOR POWER CONNECTION TO MIN FROM ROOF EDGE.SEE DETAIL FOR W m I A. ALL IS NEW UNLESS NOTED OTHERWISE. ALL MECHANICAL EQUIPMENT MOUNTING,SIZE AND ROUTE INSULATED 0 0 REFRIG.LINES FROM ROOF UNIT TO FCU(LINE C9 M M B. INSULATE DUCTWORK PER CODE AND SPEC REQUIREMENTS(ALL NOT 2.SIZE TO MATCH UNIT CONNECTION. NOT SHOWN). � Z ti ii SHOWN).COORD.CLEARANCE REQUIREMENTS FOR ADDED INSULATION 3.COORDINATE THERMOSTAT LOCATION WITH 7.MOUNT ABOVE CEILING.COORDINATE W/GC G U nr OWNER,TENANT,OR GENERAL CONTRACTOR FOR SUPPORT AND ACCESS TO UNIT. W J_ 0 4.PROVIDE A 2-POSITION ISOLATION DAMPER WITH ACTUATOR AS CLOSE AS POSSIBLE TO W` m ROOF PENETRATION J 5.INSTALL TRAPPED INSULATED TERMINATE Q CONDENSATE DRAIN IN APPROVED LOCATION. /n 2 Z H W � W J W I O o a ,o � /1 J m W Q 'u, a v � 3 N Z Z L a W a W0 W sent �,TaER C. oQ a 504 K orsTeae° SSrONAL B to r LU ---- - ---- ------ - 14.® 24xi0 (n _ S' 1tl f EE --- ------------ ------ — 22x1- - W 1-5- ' 8°0 P I S7 0• 1 R1 \ (SEE DETOF) NOT IN SCOPE (, Z 1: 28x10I M W ow • T.® HP 6 2 a Z 0 5 - - - z wrn 1 2 0 R, x10 w rrnn z 14.0 1Y/ 7 H V > FCU 1 2 3 W wo Z aZ w J .0 IIIITITL/i � � 12 2 O m � ,oz 1I 28x1O L Of ww g•a � �a 0 8"6 evisioNs 1111 _= 6•p EYM-2 5, B EAK -- Eo - - u ALL Ord (XFER) 8•b ------ SHEET TITLE 1 1 EXISTING SEMI-HEATED WAREHOUSE MECHANICAL HVAC PLAN Permit Set MECHANICAL HVAC PLAN N SCALE: 1/4"=V-0" 0 2' 4' g' CHECKED BY TIM CARR SHEET M2.01 Z COORDINATE CONNECTION/METHOD OF CONNECTION TO (5 n SHOP FABRICATED SHT.MTL CLG 20 ga.GALVANIZED SHEET METAL HOOD STRUCTURE IN FIELD AND WITH STRUCT.PLANS(TYP.) HP(AT ROOF OF WAREHOUSE) W DIFFUSER CAP,NET INSIDE DIM. Z O SAME AS DIFFUSER NECK ROUND INSUL STUB DUCT SAME SIZE AS FLEX DUCT HOOD AT PIPING C9 M M HANGER STRAP PENETRATION OF /� Z FLEX DUCT CLAMP SELF TAPPING SCREWS UNISTRUT HANGER ROOF MEMBRANE. {ate G 6 � EQUALIZING GRID PERPENDICULAR TO (SEE DETAIL ON J S STUB DUCT. FULL SIZE OF DIFFUSER FLEX DUCT,PULL INSIDE GALVANIZED MESH THREADED ROD THIS SHEET). G CAP. HEIGHT FROM DIFFUSER NECK SCREENING W TO STUB CENTERLINE. FABRICATE LINER TAUT 45' PR LOW RE DUCT FROM 22ga.PERFERATED SHT.MTL. 7 m (3/16"HOLES ON 1/4"CENTERS) DUCT ` J FLASHING,ROOFING AND SEALING Q PER ROOFING CONTRACTOR'S FOR DUCTS OVER 48" INSTALL CABLE SEISMIC RESTRAINTS BOTH 2 REQUIREMENTS � � 12"MIN. WIDE,TURN UNDER BOT LONGITUDINALLY AND TRANSVERSELY PER F TOP OF ROOF DECK OF DUCT&FASTEN SMACNA REQUIREMENTS W CLG DIFFUSER: FASTEN TO CAP W/SHT.MTL SCREWS, DUCT SIZE HANGER SIZE MAX.SPACING J MIN.ONE PER SIDE. SEAL JOINT AIR TIGHT. UP THRU 2 SQ.FT. 1"z 1/16" 8-0" W NOTES: 2 THRU 4 SQ.FT. 1"x 1 8" 8-0 ANGLE FASTNERS M ROOF CURB / T a o�i TYP.SUSP.LAY-IN SMILING 4 THRU 10 SQ.FT. 1 z 1 8 6-0 i 1. PROVIDE SUPPORT FOR DIFFUSER&CAP / Q m PER CODE. MOTORIZED DAMPER) DUCT(INTAKE OR EXHAUST) UVLK 1 1°x 1/8" 4-0 J F C 2. EQUALIZING GRID REQ'D ON SUPPLY AIR M Q DIFFUSERS ONLY. INSULATE OUTSIDE PROVIDE NEW SLEEPERS FASTENED W V y AIR INTAKE TO STRUCTURE. Z tj H LAY-IN CLG DIFFUSER a GRILLE ROOF PENETRATION DETAIL DUCT HANGING DETAIL HP PIPING DETAIL w (j = o (FOR USE IN LIMITED CEILING SPACE) Scale: NTS Scale: NTS Scale: NTS 4 Scale: NTS 20 ga.GALVANIZED SHEET METAL HOOD FILL OPENING W/FOAM TeER C. — — INSULATION,AIR TIGHT,AFTER 'VOQa — — LINES ARE INSTALLED ROOF CURB GALVANIZED MESH II a soa ^ SCREENING FLASHING,ROOFING AND z I SEALING PER ROOFING aNAL CONTRACTOR'S REQUIREMENTS TOP OF ROOF DECK UNISTRUT ANCHORED TO CURB, CLAMP REFRIGERANT LINES TO REFRIGERANT LINES UNISTRUT (INSTALL PER CODE) NOTE: THIS ROOFING PENETRATION DETAIL IS TO BE USED FOR REFRIGERANT LINES SERVING CONDENSER AND/OR HEAT PUMPS. n REF. PIPING ROOF PENETRATION 12� w J Scale: NTS U) a w iU z — > 01' W o_ U) Z r 0 2 Z N z wrn LLJ UI r a Z az zo } w r O m "Z a O' Q �a evisioNs SHEET TITLE MECHANICAL DETAILS Permit Set DESIGNER CHI-OE MOORE CHECKED BY CHRIS RENSCH SHEET M5.01 Z N fn � tD M z o °° 0 0 �j Z O k 0 U W EQUIPMENT SCHEDULES w m ZJ a Z Lu W SPLIT SYSTEM SCHEDULE w W UNIT INFORMATION COOLING HEATING AIRFLOW POWER SOUND&WEIGHT O o COOLING STAGES HEATING STAGES TOTAL MIN.VENT ESP MOTOR MCA MOCP SOUND UNIT I Q o TAG DESCRIPTION MANUFACTURER MODEL CPY(BTUH) SEER COOLING CPY(BTUH) COP HSPF HEATING AIRFLOW(CFM) AIRFLOW(CFM) (IN.W.C.) HP VOLTAGE (AMPS) (AMPS) (dBA) WEIGHT(LBS) NOTES J F a HP SPLIT HEAT PUMP UNIT DAIKIN RXTQ48TAVJU 45500 16 1 49,500 NA 9 NA NA NA NA NA 208/230 29.1 35 58 176 [1][2][3] V H 3 FCU CONCEALED DUCTED INDOOR UNIT DAIKIN FXSQ48TAVJU NA NA 1 NA NA NA NA 1,307 918 0.6 NA 208/230 2.8 15 42 104 [1][2][4] Zd y NOTES: = i 0 [1]COORDINATE FINAL MOUNTING LOCATION WITH BUILDING OWNER V 0 [2]MAINTAIN MANUFACTURER'S OF CODE CLEARANCES-WHICH EVER IS GREATER W [3]PROVIDE SLEEPERS FOR MOUNTING AT ROOF-COORDINATE ACTUAL LOCATION WITH G.0 [4]PROVIDE CLEAN FILTERS PRIOR TO HAND OFF-TO OWNER ERV SCHEDULE EXHAUST SUPPLY STATIC ERV HEATING TAG DESCRIPTION MANUFACTURER MODEL CFM CFM PRESSURE EFFECTIVENESS SOUND(dBA) VOLTAGE AMP MOP WEIGHT(LB) NOTES ERV-1 ENERGY RECOVERY VENTILATOR FANTECH I ATM0200E 1 195.0 195.0 0.4 75%SENSIBLE NA 120/1 1.4 NA 1 57 1 [1][2] o504 n NOTES: Ss aL�yO [1]COORDINATE POWER REQUIRMENTS WITH ELECTRICAL CONTRACTOR [2]PROVIDE WITH ECOTOUCH PROGRAMMABLE CONTROL FOR OPERATION WHEN FACILITY 15 OCCUPIED AND OFF WHEN UNOCCUPIED AIR TERMINALS SCHEDULE MARK DESCRIPTION MOUNTING LOCATION MANUFACTURER MODEL NECK SIZE(INCHES) FACE SIZE(INCHES) FINISH NOTES LOUVERED SUPPLY DIFFUSER 4- S-1 T-BAR CEILING SHOEMAKER HVD SEE PLANS 24X24 WHITE FACTORY WAY E-1 EXHAUSE BLADE GRILLE W/45° HARD LID SHOEMAKER 905 10X10 12X12 WHITE FACTORY FIXED BLADES L1J RETURN/XFER FIXED 45°BAR R-1 T-BAR CEILING SHOEMAKER 915T 22X10 24X12 WHITE FACTORY U) BLADE GRILLE Q X-1 TRANSFER BLADE GRILLE W/45° HARD LID SHOEMAKER 905 10X10 12X12 WHITE FACTORY Lu FIXED BLADES Ll.l iU z — Lu yj O W CONTROLSANDDEVICESSCHEDULE Z OPERATING ~ z O TAG DESCRIPTION MANUFACTURER MODEL POWER CONTROLSIGNAL TORQUE NOTES Z f wrn T PROGRAMMABLE THERMOSTAT HONEYWELL TB710OA1000 24VAC CONTACTS NA [1] (UI d3 MOTORIZED ISOLATION DAMPER 2-POSITION w Z aZ M BELIMO OR EQUAL 24VAC ON/OFF TBD [1][2] 0 J 4� ACTUATOR (ON/OFF) NOTES: p [1]COORDINATE MOUNTING LOCATION WITH GENERALCONTRACTOR [2]INTERLOCK DAMPER WITH DOAS UNIT REVISIONS ELECTRIC HEATERS THERMOSTAT TAG DESCRIPTION SERVES MFG. MODEL WATTS CFM TYPE VOLTAGE AMPS NOTES FACTORY EWH-101 WALL-MOUNTED FAN-FOCRED TOILET 109 KING ELECTRIC PAW1215 250.0 2.083 MOUNTED 120/60/1 2.1 [1][2] ELECTRIC WALL HEATER INTEGRAL FACTORY EWH-102 WALL-MOUNTED FAN-FOCRED TOILET 110 KING ELECTRIC PAW1215 250.0 2.083 MOUNTED 120/60/1 2.1 [1][2] ELECTRIC WALL HEATER INTEGRAL NOTES: SHEET TITLE 1.COORDINATE POWER CONNECTION WITH ELECTRICAL CONTRACTOR MECHANICAL SCHEDULES Permit Set DRXVN BY DESIGNER CHECKED BY SHEET M6.01 ' CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17216 51ST AVE NE SUITE 108 Permit#: 5404 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100400100 DATE OF ISSUANCE. Scope of Work:Addition of a ducted 4 ton split heat pump with ERV Valuation:47000.00 OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Five Star Mechanical Five Star Mechanical INDUSTRIAL PARKM QOZB,LLC 8201 164TH AVE NW 7509 Grange St W 7509 Grange St.West REDMOND,WA 98052 Lakewood,WA 98499 Lakewood,WA 98499 206-491-1973 206-786-8278 LIC:FIVESM*OIOJT EXP:05/01/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC I O/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 07/14/2023 Applicant Signature Date Building Official Date CONDITIONS ADHERE TO APPROVED PLANS.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/17/2023 Processing/Technology $25.00 07/17/2023 Air Handling Unit $25.00 07/17/2023 Ductwork/Dryer Duct $25.00 07/17/2023 Heat Pump-Condensing Unit $25.00 07/17/2023 Mechanical Commercial Plan Review $598.99 Total Due: $698.99 Total Payment: $0.00 Balance Due: $698.99 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail _ _ _ Z r m ABBREVIATED SPECIFICATIONS MECHANICAL SHEET INDEX Z W qT,1 NOTE:NOT ALL SPECIFICATION SECTIONS MAY BE NEEDED FOR THIS PROJECT,CONTRACTOR TO APPLY SPEC.SECTIONS AS APPLICABLE TO SCOPE OF WORK. Q M W GENERAL MECHANICAL DUCTWORK AND ACCESSORIES(CONT.) n CONTROLS AND OPERATION Sheet List Table li Z CODES: DAMPERS:FURNISH AND INSTALL(F&I)DAMPERS IN ACCORDANCE WITH THE m PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT MECHANICAL CODE, FOLLOWING TYPES AND FUNCTIONS: Sheet Number Sheet Title Q STATE AND LOCAL CODES/ORDINANCES AND AHJ.ALL WORK SHALL ALSO BE THE MECHANICAL CONTRACTOR SHALL F&I ALL CONTROL WIRING NECESSARY FOR W J e IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. .BALANCING DAMPERS:SINGLE BLADE LOCKABLE MANUAL SETTING OR ON THE COMPLETE SYSTEM INCLUDING ALL MODES OF OPERATION AND INTERLOCKS. M0.01 MECHANICAL SPECIFICATIONS j THE MECHANICAL CONTRACTOR SHALL COORDINATE MECHANICAL WORK WITH LARGER DUCTS,MULTI-BLADE RECTANGULAR WITH LOCKABLE MANUAL OTHER TRADES.THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE SETTING. SEE PLANS FOR FURTHER CONTROL REQUIREMENTS. MO.11 MECHANICAL ENERGY FORMS W m OVER ALL OTHER DRAWINGS.DO NOT SCALE DISTANCES OFF THE MECHANICAL •ISOLATION DAMPERS IN ROUND DUCTS:SINGLE BLADE TYPE ` J DRAWINGS;USE ACTUAL BUILDING DIMENSIONS. •SOLATION DAMPERS IN RECTANGULAR DUCTS:PARALLEL MULTI-BLADE M2.01 MECHANICAL HVAC PLAN a TYPE HVAC UNIT(S)TEMPERATURE CONTROLS STANDARDS:EQUIPMENT AND MATERIALS SHALL CONFORM WITH •ZONE CONTROL DAMPERS IN ROUND DUCTS:SINGLE ROUND BLADE PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT M5.01 MECHANICAL DETAILS APPROPRIATE PROVISIONS OF ARL,ASME,ASTM,UL,NEMA,ANSI,SMACNA, •CONTROL DAMPERS IN RECTANGULAR DUCTS:OPPOSED MULTI-BLADE ASHRAE,NFPA,OTHER APPLICABLE AGENCIES AND AHJ,AS APPLICABLE TO TYPE Me.01 MECHANICAL SCHEDULES I.. 1. FOLLOW MANUFACTURER'S INSTRUCTIONS WHEN INSTALLING THE SPACE EACH INDIVIDUAL UNIT OR ASSEMBLY. C1 TEMPERATURE CONTROLLER(THERMOSTAT OR SENSOR) ISOLATION DAMPER AIR LEAKAGE:DAMPER SHALL BE OF CLASS I LEAKAGE W W SITE EXAMINATION:THE MECHANICAL CONTRACTOR SHALL THOROUGHLY SPECIFICATION AS PER IMC 2018 AND WSEC 2018 2.THE HEAT PUMP THERMOSTAT IS SHOWN ON THE DRAWINGS IN A RECOMMENDED j EXAMINE ALL AREAS WHERE EQUIPMENT,DUCTWORK AND PIPING WILL BE LOCATION.COORDINATE WITH THE TENANT OR OWNER,IF THE LOCATION LU INSTALLED AND SHALL REPORT ANY CONDITION THAT PREVENTS THE PROPER INDICATED IS NOT SUITABLE DUE TO FURNISHINGS,APPLIANCES,OR Q c INSTALLATION OF THE MECHANICAL WORK. GRILLES,REGISTERS&DIFFUSERS:GRILLES,REGISTERS AND DIFFUSERS APPURTENANCES.VERIFY WITH THE ENGINEER OF RECORD THAT THE PROPOSED SHALL BE AS SCHEDULED AND SHALL BE FURNISHED AND INSTALLED BY THE ALTERNATE LOCATION IS ACCEPTABLE. = Z MECHANICAL CONTRACTOR.DIFFUSERS SHALL BE INSTALLED AS INDICATED ON 3.PROGRAM THE THERMOSTAT IN ACCORDANCE WITH THE 2018 WASHINGTON Q m HVAC EQUIPMENT&MATERIALS THE DRAWINGS AND SCHEDULES.THE MECHANICAL CONTRACTOR SHALL STATE ENERGY CODE SECTION C403.4 PROVIDING TIME OF DAY AND WEEKLY MECHANICAL LEGEND PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETE AND OCCUPANCY SCHEDULES,NIGHT SETBACK CAPABILITY(55•F FOR HEATING AND Q HVAC UNITS:UNIT$SHALL BE AS SPECIFIED IN PLANS AND SHALL BE PROPER INSTALLATION IN THE TYPE OF WALLS USED IN THISPROJECT. 85-F FOR COOLING),5 DEGREE DEADBAND BETWEEN HEATING AND COOLING C1 O 3 FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR.THE SETPOINTS,MAXIMUM OF 2-HOUR MANUAL OVERRIDE,AUTOMATIC START AND 7 N I MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THERMAL INSULATION:PROVIDE EXTERNAL THERMAL INSULATION WITH AN STOP FUNCTION THAT REDUCES THE HEATING SETPOINT AND INCREASES THE NOTE:NOT ALL SYMBOLS MAY BE USED IN THESE DRAWINGS. La` Z U DELIVERY,PROVIDING COMPLETE INSTALLATION INCLUDING CURBS,PIPES, INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL, COOLING SETPOINT BASED ON THERMAL LAG AND ACCEPTABLE DRIFT FOR A ` Q W f VIBRATION ISOLATION AND NECESSARY ACCESSORIES,AS WELL AS PROVIDING STATE ENERGY CODE AND A.H.J.REQUIREMENTS.PROVIDE INSULATION ON PERIOD OF 30 MINUTES BEFORE SCHEDULED UNOCCUPANCY. W I > O WARRANT(. EXHAUST AND OUTSIDE AIR DUCTS AND ON CONCEALED PORTIONS OF SUPPLY 4.TO PROVIDE BOTH OCCUPIED SETPOINT AS WELL AS NIGHT SET-BACK(OR AND RETURN AIR DUCTS.DO NOT INSULATE EXPOSED DUCTWORK WITHIN THE Imo- W Q O EXHAUST FANS&ERVS:UNITS SHALL BE AS SPECIFIED IN PLANS AND SHALL BE SPACE AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED.THERMAL UNOCCUPIED)FUNCTION WHEN THE FACILITY IS NOT OCCUPIED. I X;_ I X I TYP.SUPPLY DUCT UP/DN _ FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR.THE INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS AND 5.THE UNIT FAN SHALL BE PROGRAMMED AT THE THERMOSTAT TO RUN AS VN� Ir— DUCT HEATER � � N MECHANICAL IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH SMOKE DEVELOPED NO GREATER THAN 50. FOLLOWS: I��/;, OF MANUAL VOLUME DAMPER NEW AND EXISTING VENTS AND INTAKES,PROVIDING COMPLETE INSTALLATION L I. Z TYP.RETURN DUCT UP/DN INCLUDING DUCTWORK TO UNIT AND NECESSARY ACCESSORIES AND ACOUSTIC DUCT LINER:UNLESS OTHERWISE INDICATED ON THE PLANS,F81 1" • CALLS FOR HEATING OR COOLING;MAXIMUM SPEED BASED ON CFMS PROVIDING WARRANTY. GLASS FIBER ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK INDICATED. ON J� IU-P�I- ❑❑ BACK DRAFT DAMPER WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. • OCCUPIED(NON HEATING OR COOLING);SET AT LOW SPEED I.0' I.0 I TYp,EXHAUST DUCT UP/DN BAROMETRIC DAMPER DUCTWORK AND ACCESSORIES INCREASE DUCT SIZED INDICATED ON PLANS 2"IN EACH DIMENSION TO UNOCCUPIED;CYCLES WITH HEATING/COOLING FUNCTIONS F."r v ACCOMMODATE LINER.LINER SHALL BE FASTENED TO DUCT WITH MECHANICAL ❑ SHEETMETAL DUCTWORK:ALL DUCTWORK SHALL BE RIGID SHEETMETAL LINER FASTENERS IN ACCORDANCE WITH SMACNA. TURNING VANES w DUCT SMOKE DETECTOR CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH (''j MOTORIZED DAMPER ,LpPNER C. SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS.FIBERGLASS TESTING,ADJUSTING,AND BALANCING DOAS/ERV UNITS �S�op WA DUCTBOARD IS NOT ALLOWED.ALL EXPOSED DUCTWORK SHALL BE ROUND, OT THERMOSTAT COMBINATION SMOKE AND FIRE G�1 SPIRAL OR RECTANGULAR LOCK-SEAM TYPE,AS SHOWN ON HVAC PLAN, MECHANICAL CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS 1. DOAS UNIT INCLUDES A FACTORY-PROVIDED CONTROLLER AS A USER DAMPER J ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED TO PROVIDE AIR QUANTITIES TO ALL ZONES AS INDICATED ON THE DRAWINGS INTERFACE.THE CONTROLLER SHALL BE CAPABLE OF SETTING TIME OF DAY AND S INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT(5%LEAKAGE)AND NOISELESS AND IN THIS SPECIFICATION.THIS SHALL INCLUDE BALANCING AIR FLOWS AT WEEKLY OCCUPANCY SCHEDULES.IN ACCORDANCE WITH WSEC 201 B.THIS SENSOR 0 SPIN-IN TAKE-OFF AND VOLUME (NO OBJECTIONABLE NOISE)SYSTEMS,CAPABLE OF PERFORMING EACH DISCHARGE AND INTAKE TERMINALS AS WELL AS BALANCING FAN SYSTEMS. TIMING CONTROL MAY ALSO BE INTEGRATED INTO THE AIR HANDLER DAMPER / 504 v,4' INDICATED SERVICE,FURNISH ALL REQUIRED DAMPERS,TRANSITIONS, BALANCNG FAN SYSTEMS WILL REQUIRE(AT A MINIMUM)THE MEASURING AND THERMOSTAT CONTROL IF THERE IS A VENTILATION AUXILIARY CONTACT. SUPPLY AIR ARROW ����� ISTeseO NALe�O CONNECTIONS TO AIR TERMINALS AND OTHER ACCESSORIES NECESSARY FOR ADJUSTING OF THE FOLLOWING PARAMETERS: l:T- UNDERCUT DOOR SS�O A COMPLETE OPERATING SYSTEM,NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. •SUPPLY AND RETURN STATIC PRESSURES RETURN AIR ARROW •DRIVE RPM'S ELECTRIC WALL HEATERS FLEXIBLE DUCTWORK:FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS •TEMPERATURE DIFFERENTIALS(HEATING AND COOLING SHOWN IN PLAN.FLEXIBLE DUCTWORK SHALL BE PULLED TAUT AND 1. ELECTRIC WALL HEATERS SHALL BE INSTALLED WITH A FACTORY MOUNTED APPROPRIATELY FASTENED TO RIGID BRANCH DUCT&DIFFUSER.BENDS SHALL WHERE QUANTITIES ARE NOT INDICATED BALANCE PER INDUSTRY STANDARD INTEGRAL THERMOSTAT SET AT 55°F. BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND.SUPPORT BANDS TO PROVIDE A PROPERLY WORKING SYSTEM.OPERATE AUTOMATIC CONTROLS 12 X 8 SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT.FLEXIBLE DUCTWORK SYSTEM AND VERIFY SET POINTS. INDICATES UNLINED 12"x 8"O.D.SHEETMETAL SHALL 8E UL 181 LISTED AS A CLASS 1 AIR DUCT. (1ST FIGURE=SIDE SHOWN DUCT SEALANT:SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A SYSTEM COMMISSIONING 2ND FIGURE SIDE NOT SHOWN) NON-HARDENING,NON-MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND NOT REQUIRED SEAMS IN SHEET METAL DUCTWORK.COVER ALL FIELD JOINTS,JOINTS AROUND SPIN-IN FITTINGS AND FASTENING SCREWS WITH MASTIC. IIIIIIIIIIIIIIIIIIIIII SUPPORTS:PROVIDE HOT-DIPPED GALVANIZED STEEL,FASTENERS,ANCHORS, FLEXIBLE DUCT RODS,STRAPS,TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. N XX-X DIFFUSER SIZE L1J XXXX DESIGN CFM(WHERE APPLICABLE)CFM I- SHOWN FOR RETURN ARE UNOCCUPIED MODE (n Q ' G C 1A I C p/1 I 1A I OT E C+ O CEILING DIFFUSER(FLOW ARROWS SHOWN G I V E RA L I V J INDICATE DIRECTION OF AIR FLOWS) w I= U Uj 'A z 1. ALL IS NEW UNLESS OTHERWISE NOTED. El c Y_ CEILING RETURN/EXHAUST GRILLE nN/ 2. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS,FLOORS,CEILINGS UJ L.L OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED O L11 ! DURING THE COURSE OF WORK, 9DETAIL MARK W (n 3, DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S).FOLLOW DRAWINGS IN LAYING OUT WORK AND F. Z CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE CONDITIONS.MAINTAIN XX XX DETAIL MARK Z O m 1 - HEADROOM AND SPACE CONDITION. MX.X Z �. ! SHEET WHERE DETAIL IS SHOWN /� w 4. ALL NEW HVAC DUCTWORK AND EQUIPMENT SHALL BE SUPPORTED FROM THE H V 3 STRUCTURAL CEILING OR PLATFORM(CONFIRM). F W Z Q Z 5. NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED WHERE IT XXXXX EQUIPMENT MARK-SEE SCHEDULE U d m O } OBSTRUCTS ANY EXISTING AREAS THAT REQUIRE ACCESS(e.g.FIRE/SMOKE W(� J G 0 ACCESS PANELS,VALVES,ETC.). O m � m 2 Q_ Q �a MECHANICAL ABBREVIATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUM AHJ AUTHORITIES HAVING MECH MECHANICAL JURISDICTION MC MECHANICAL CONTRACTOR AHU AIR HANDLING UNIT MEP MECHANICAL,ELECTRICAL APPROX APPROXIMATE AND PLUMBING MFG MANUFACTURER BLDG BUILDING MIN MINIMUM 8 MOF MAKE ON FALL(THERMOSTAT) ' C CONDENSATE PIPING MOR MAKE ON RISE(THERMOSTAT) CLG CEILING CONST CONSTRUCTION "NC" NORMALLY CLOSED(CONTACT) CD CEILING DIFFUSER "NO" NORMALLY OPEN(CONTACT) PROJECT SUMMARY NITS NOT TO SCALE DATE DEG DEGREES A NEW SHELL BUILDING SPACE SHALL BE REMODELED TO SERVE AS A NEW OFFICE oenTrsoxB DTL DETAIL OSA OUTSIDE AIR SPACE WITHIN A LARGE EXISTING WAREHOUSE.THE HVAC SYSTEM SHALL BE A SPLIT DN DOWN SYSTEM HEAT PUMP WITH DUCTED AIR HANDLER.A DOAS SYSTEM WITH ERV SHALL SHEET nnE PROVIDE DWG(S) DRAWING(S) THE OFFICE SPACE VENTILATION NEEDS,EXHAUSTING FROM THE OFFICE MECHANICAL S DOAS DEDICATED OUTSIDE AIR SYSTEM PM PROJECT MANAGER RESTROOM AND BREAKROOM AND DELIVERING FRESH AIR TO EACH SPACE IN THE REF REFERENCE NEW OFFICE.THE EXISTING WAREHOUSE SYSTEM GAS HEATER(S)WILL REMAIN s EA EACH REQ('D) REQUIRE(D) UNCHANGED. SPECIFICATIONS C E ELECTRICAL CONTRACTOR REV REVISED/REVISION ELEC ELECTRICAL RO RETURN GRILLE EF EXHAUST FAN RL REFRIGERATION LIQUID LINE EM EMERGENCY IRS REFRGERATION SUCTION LINE (E)OR(EX)EXISTING EXT EXTERIOR BHT SHEET EG EXHAUST GRILLE SPECS SPECIFICATION(S) EWH ELECTRIC WALL HEATER SF SQUARE FEET SS STAINLESS STEEL F&1 FURNISH&INSTALL CI�OFf�I.�I�'CiTOIV Permit Set FLOOR TEMP TEMPORARY BUILDING DEPARTMENT FT FOOT/FEET TYP TYPICAL APPROVED GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE DATE RPCEIVEd ;. , BY' BE O HP HEAT PUMP WH WATER HEATER oeBicNEa: cHLoE MooPE HR HOUR HVAC COND T ONING EATING 8 AIR NO CHANGES AL1TH^RIZr,p 2"✓'"�1 SHEET HEATING UNLES9 APPROVED 11Y 1.,2 CHECKED BT: CXWS RENSDN tip LL LANDLORD BUILDING INSPECTOR LV LOW VOLTAGE /' w .O.O I i Z n m WSEC 2018 ENERGY CODE t7 W LOAD CALCULATIONS MATRIX z Z 0 R MOTOREFFICIENCY FAN MOTORS NOT COVERED BY TABLE C405.8(3)AND C4L5e(4)SHALL Be ELECTRONICALLY (FRACTIONAL-1/12 HE COMMUTATED(EC)OR SWILL HOVE A MINIMUM MOTOR EFFIDENLY OF 7M WHEN RATED IN W DESCRIPTION 3 1 HP) ACCORDANCE WnH DOE 10 CFR 431. W HEATING AND WOUNG LOAD CALGUN.A710NS E BEEN COMPLETED IN COMPLIANCE WITH THE m System Checksums SONG REQUIREMENTS ENERGY ODDE AND THE RESU IL S ARE INCLUDED N THESE PLANS.UNITS HAVE BEEN SIZED TO VENTILATION MINIMUM VENTILATION IS SETAT NO MORE THAN 150k OF DESIGN REQUIREMENTS AS DEFINED BY THE Z J BY RENSCH ENGINEERING THE MINIMUM AVAILABLE OUTPUTGPA I TIE MECHANICAL WOE. S PROVIDED BY THE MANUFACTURER, _ a UNIT Incremental Heat PUMP WAC PIPE INSULATION gGUfA7E ALL REFRIGERANTPIPING PER TABLE C403.2.p. - THERMOSTATS ZONE TIERMOSTAl1C CONRROLS ARE PROVIDED ITIi A TEMPERATURE RANGE OR DEADBANA OF AT COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES LEAST 5°F WHERE USED FOR BOTH COOLING HEATER SETPOINTS.(SEE THERMOSTAT NOTES) FANAIRFLOAI FAN MOTORS NOT COVERED BY TABLE C/08.8(3)AND C405.8(4)SMALL BEELECTROMCALLY Z I- Heak,f.i ime: M1a'. - 5 M Hi.S.rn of Muni,H- gUeepu C Il g Heatingy COMMIRATED(EC)OR 3HALL HAVEAMIWMLp/MOTOREFFICENCyo,, %WI£NRAMDN JcAr: OACB..H Hn 9 FiJ:-' OArE F,.a.s OADR 2d $ADS h= a05 EACHZONE SHALLBEPRWIDEDWITHTHERMOST TIC SETBACK CONTROLS TIHATARE CONTROLLED BY EFFICIENCY V ACCORDANCE WITH DOE 10 CFR 131. Re Plenum ! 'O 0 ETIIER AN A1/10MAliC TIME CLOd(OR PROG MABLE CONTROL SYSTEM.SETBACK CONTROLS W W THERMOSTAT SETBACK Space Plenum Net Percent Space Percent Space Peah Coll Peak PereaM Return 2I "I SHALL HAVE THE CAPABILITY TO SETBACK ORTEM ORARA_YOPERATETHESYSTEMTOMA ANZDW DEDICATED OUTDOOR J Sxns.-Lat Sens TLal Total Of Total Sensible Of Total Space Sens Tot Sens Of Total R.. 725 678 TEMPERATURES DOWN To 55T OR TO 85°F.(SEE THERMOSTAT NOTES). AIR SYSTEMS foo") DOHS SWWLL BE PROVIDED FOR OFFICE SPACES IL Bv:F Bb/h 8:cn (`ie) B[c:.^ ( I 131 A B (YI Fn BMTD 0.1 00 ENERGY COVERY COMBSHALLNCLUDEENERGYWE ERVVEN TIONTIATCOMPUESWRHTHEMIMML.MENERGY 0 O 117 I p ds F 1 pe Lnads AUTOMATIC START AUTOMATIC START CONTROLS SHALL BE PROVID FOR EACH WAC SYSTEM.THE CONTROLS SHALL yEWLATION WITH WAS RECOVERY EFFICIENCY AND ENERGY RECOVERY BYPASS REQUIREMENTS. V QI t r C 0 0 0 Sk 3 lar Fn Frk1 0.3 ON CONTROLS BE CAPABLE OF AUTOMATICALLY ADJUSTING THE DAILY START TIME OF THE HVAC SYSTEM IN ORDER Z �d 0 0 0 0 G 7 }' end 3 ].0G HEATING/COOUfS O N H C J C 0 0 R J 30 (OPTIMUM/MORNING TO SRNG EACH SPACE TO THE DESIRED UPIED TEMPERATURE IMMEPIATELY PRDR TO a O E)CEPTION:PRIMARY SUPPLY FAN My RUNATLOW SPEED PROVIDED IiIISES NO MORE THAN 0.12 'Al m 1 fi6'.H 0 6516 21 701E r I ,: AIRFLOWS STARTUP) SC1ED)LE OCCUPANCY. SYSTEM FAN CONTROLS W/CEP J r Q GI 1.261, 0 12.:C 4 i 1 2 s,U ::ard C.-26 - 5+ C 1 g Heating /� d 4-12 6 49 1 683 3 C EES 9 2J1 DiHucx DCV DEMAND CONTROL VENTILATIONG T PROVIDED SINCE LESS THAN 7W CFM W V w It 826 2E2'c 9 826 1 rt'�r cap 64 2. d6' 1'667 MECHANICAL MECWIMCAL COMMISSIONNGGNOTREQURED SINCE SYSTEM CAPACIIYGNOTABOVE 2404BH �/ F C 0 10 FI -1b S 45 Terminal 1 b6' 1.667 COMMISSIOMNG COOl1NG. _ 1 I.1 01IC 0.00 l 000 CC t FI«; I`C3 0 )00 Main Fan 1,667 1.fi61 ALL DUCTNORI(SHALL BE CONSTRUCTED ANDS FLED PER THE INTERIJATONAL MECHANICAL CODE a Cl W T'vG _C + %1 (1. Oi ta.TG Sec Fan 0 0 (MC),WASHINGTON STATE ENERGY CODE C1 LEAKAGE REQUIREMENTS AND INTERNATIONAL uk Tote._• 1.872 6 11.8I8 3? "'.198 �,,., o,a._ ..i. 1 i=5 d2 JC+ Nom Vent 202 202 DUCTWORK SLAIDING CODE(IBC)VAPOR RETARDER REQUIRE ENTS.IF SPECIFICATIONS FOR DUCT CONSTRUCTION yf + AHU Vent 202 202 AND LEAKAGE REQUIREMENTS ON PLANS AIRE MORE STRINGENT THAN CORRESPONDING CODE THE FOLLOWING SHALL BE PROVIDEDTO THE SLOLDNG OWNER OR OWNERS AUTHORIZED AGENT Q = InfemaI Loads I Loads Inb 71 71 REQUIREMENTS,SPECIFICATION ON PLANS SHALL BE ADHERED TO. WITHIN 1M DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY: W O '..is 2 E 804 4 8 13 1 L 's 0 0 GCG MinStopiRh 0 0 RECORD DOCUMENTS(CONSTRUCTION DOCUMENTS UPDATED TD C Z cp a "I 0 9".:' 29 38 'l n 0 D 00L+ Return f,737 1,737 BUILDING CONVEY RECORD OF COMPLETED WORK) L r• M s.022 0 5.02_ 16 5.t2: 1- 5:'s_ 0 0 C.3G Exhaust 272 272 LOW-PRESSURE DUCT ALL DUCTWORK SHALL BE OF THE TYPE:"LOW SSURE DUCT SYSTEMS",STATC PRESSURE NOT TO OLDS MENTATIONAND MANUALS(OPERATING AND MAINTENANCE MANU M-FDR EACH SC e=_- 1755E 904 78.'=9 57 13.63; -o..e=_> 0 0 rJ.3C Rm Exh O 0 SYSTEMS MEE 12 IN.W.G. OLDS PIECE OFEOUPMENTREQUIREDTO BECOMMISSIONEDBYTHE Auxlllary 0 0 REQUIREMENTS ENERGY CODE. Ceiling Load 809 _W9 0 0 311 J f'iing Load -13 C CCO Leakage Dam 0 0 FAN AIRFLOW CONTROL WA-ALL SYSTEMS RE LESS THAN 65 MBH, COMPLIANCE DOCUMENTATION(AU-ENERGY WOE COMPLIANCE Ventilation Load 0 0 958 3 0 V...ilatI..Load D AM 175P Leakage Ups 0 0 FORMS AND CALOJIATDNS) SEAL AqAk Trsns Heat 0 0 0 0 G Atlj Air Trans Neat 0 0 - SEE CIWa OF THE CURRENT WSEC FORA COMPLETE DESCRIPTION OF WHAT IS REQUIRED. DehumJ OY Sizing 0 0 OY'Undr saing 0 0 -L DUCT INSULATION: AR DUCTS SHALL BE INSl1LAlED AS STA DELSEWHERE AND PER THE FOLLOWING: OvlUndr Sizing 0 0 0 0 D Exhaust Heat 0 '0 ENGINEERING CKS SUPPLY AND RETURN OUTSIDE BUILDNG=Re MIN UNCONDITIONED SPACE=ITS MIN 6havat Heat 0 0 0 OA Preheat Dill 0 30' Codingg Heating AIRPLENUMS SUPPLY DUCTS(105°F<AR TEMP<55° WITHIN CONDITIONED SPACE=R3.3 MIN Ref Fan Heal 0 7 0 0 RA Addition I DOH. 0 3 De, AOA 12.7 12 1 ,g'LOq�1TT>A G Additional Reheat 0 3 OO Duel Heat Pkup 0 0 0 cfmXla 1.13 7.13 S,O tl M",Sup HI Pkup 0 0 Und.*Sup HI Pkup 0 G.30 cf nhon 568.47 4 Supply Air Leakage 0 0 0 Supply Air Leakage 0 fPAon 50186 ECONOMIZER 9.DEDICATED OUTDOOR AIR SYSTEMS THATNTINC ENERGY RECOVERY AS REOURED BV SECTION 7a to szaN 81u1hrfiv 23.91 -24.79 EICEPTDNS 0403.7.6 BUT THAT DO NOT LUDE MECHANICAL COOLING. s5 wxnargymEes.mmvp�imp ea wm tom pnp?k awOgutr NmAmznzpFTE11mIJoaroo _ y Grand Total=� 30237 0 31986 too.DO 26,C 100.00 Grand Tool==> -19255 23,3d4 100:0 No.P.aple 22 % _ 19-apdat_1 CLASS I(LEAKAGE LESS THAN 4 CIFNVM,C 1"W.G.IN ACCORDANCE WITH AMCA 50fD) ' 4 COOLING COIL SELECTION AREAS HEATING COIL SELECTION REQ IREDON: Mk,cHANICAL colfYl LANCE SUMMARY �s5D4 F�uv Tobl Capacity Sana Cap.COIIAitfbw fntx D&WB'HR Leave DBAVDiHR Gross Tabf Glass Capee-RyCoil AiHbw EM Lvg OUTDOOR AIR SUPPLY/RETURN At OPENINGS USED FOR ARSIDE ECONOMIZER „v=��-v _ _=�=_w „�ma.ac.«y ,sx- +,. SgVO in MBh MBA tlm °F 'F gr15 F F g.::h ttr (%) MB'n cfm •F °F UST OPENINGS a-w re. AB„ pno,m,.w c,°_ w,,,:,, a.,, .,�:.e TSTE NAL Msin Clg 2 9 30.T 1667 72.9 f.0 4 69.6 56 0..7.. z`I Floor 1,471 sin Itg -06.5 i,667 6d.6 00.5 R F OUTLETS �_Jim 05,+0?3 Aux Ciy 00 �..0 0.0 0 0.0 C:0 0.0 00 ,0,� Pan 2.83d ux Htg 0.0 0 OD 0.0 -MOTORIZED DAMPERS Opt 1hM 00 00 0.0 0 01 0.0 0.0 C 3 O.0 Ins Ooor t rehear 0.0 0 0.0 0.9 .a.er.° ExFir fit EXCEPTION:MOTORIZED DAMPERS WITHIN UN ARY PACKAGED EQUIPMENT MUST HAVE MINIMUM p4 .-. Taw 29 .2 Hoof 0 0 0 1midff 0.0 0 00 0.0 LEAKAGE AVALAB MANUFACTURER FROM MANUFACTER Wail WS 290 46 )pl Vent 0.0 0 0. 00 rat Door 0 C 0 Taral -36.5 --- DAMPERS SHALL CLOSE WHEN SYSTEMS SE ED BY DAMPER ARE NOT IN USE,DURING MORNINGen.senno rpp �iKec..a Flw,u.. rmo a vd PralectNeme TRACE3700 6.3tcalculatedet1030AMon08ID52023 WARM UP,AND SETBACK OPERATION LESS REQUIRED OTHERWISE BY RIDE s.pe ooAs L zs, c.�amauw°a i-u..,N Deaset Name. ArlingbIt SeMrtmester.Vc Alter.n 1 System Checksums Repast Peg.l of l m Yalolcwpaoan Dyer Wd..t,i Aw. r...q: ) -1- N. aaa..rvaem,mee.:.p,m a.rEe , muamg�.Na,..r.p,..z Uamaoao.a..sJ•;.e u�.w. rspx..sd..m..e wtr^ a®....q..:n aer..,mo.nm,.e�u.....m,�,®s..ur..r.e.....•ea.... LL Scope&Spare CaodNbalag .1L'IEQATION_SLNCLE ZONE SYSTEaMAEQtRP56;NT cmWMws VeAaetlba WNNUeA ��'/^� V CONTROLS MATRIX °„ =.aa,w...a Q pump eer-r.a E�a�n Sc DrylaN�p�.n Wes. East w EN r,o3,a ar,P,ry ra.. �... Nn TL MECHANICAL CONTROL SUMMARY ws d aN, arduErAE_) R6. �` "° z U FAN SCHEDULING +1.sro t to too sETa cowLrts - PROGRAMMAB OCCUPIED- REMOTE B.aew traaeyc.p.<inm�ant zaeaa cap,mmpux1'm p'^z°'.a Ro�e.me aPB z.ep.,.a z.,.os.r L'iR Ea,.e,.c.opu�. W m. VENTILATION LE UNOCCUPIED * "r as zeVeao Lwr T. UNIT)SYSTE .SYSTEM MEpgERVED CONTROL TYPE CONTROL WIRING HEATING? MORNING TOTAL OCV ECONO OCCUPIED FAN INTERLOCKE 'R-'0 ...,. rswo asm sp xsNE E cop cmrezNs O W COOLING?TYPE? WRFLOW THERMOSTAT FAN CYCLING NOTES M TAG DESCRIPTION I SPECIFICATION BY? TYPE? WARM-UP CONTROL CONTROL CONTROL CONTINUO CYCLING DNATH? DAMPER W' U) CONTROL OR SPACE NTH HTG V J US FAN WITH HTG 8 INTERLOC T IL TEMPERATURE CLG ONLY z O .CONSTANT STANDMRDELECTRONC ELECTRONIC YES,OXCONSTAM Z L� SINGLE ZDNE. YES.HEAT PUMP FAN OCCIPANCY ( ) -_ _. _. nr v- I c r > >n 1.zpp EvmlroaTaoig aP 1 1rz Z ILL Zm HPIFCU VOLUhE PROGRAATN61.E PROGRANNWBLE MC SUPPLVAR X ERVIND ERV-1 X NA NOTE1 X X MULTIPLE SPACES (HP) SCHEDULING - SYSTEM THERMOSTAT THERMOSTAT TEMPERATURE SUPPLY&EUIN T F- EL QZ ENERGY FACTNTROL VIOED INTROAN H FOUSLY FNTROLL MC TO PROVIDE 2d VAC UP LATCN DAMPER EXHAUST O u,OF ERV1 RECOVERY ALL SPACES MC -- -- -' -- X -- X -- -- -- X ACTUATORS FOR BOTH SUPPLY AND EXHAUST W _I nLD VEWII ATOR CONTROL PANEL CONTROLLER COMINIOUSLV DURRRG CONTROLLER OC UPANCY TERMINATIONS. O m 0 Q NOTE:1.SET2 SPEEDSUPPLY FAN CONTROL SEE W.01 FOR ADDDTIONAL INFORMATION. - sy A a a RENSIONS VENTILATION CALCULATIONS MECHANICAL VENTILATION CALCULATION TYPEOF OCCUPANTS TOTAL SELECTED CFM PER CODE EZ TOTALREQ'D DESIGN VEN SPACE 50,FT. SPACE PER1000SF OCCUPANTS OCCUPANCY PERSON CFM/Sa FT. FACTOR VENTCFM CFM Open Office 620 Office Spaces 5 3 6 5 0.06 1 67 70 Office 106 120 Office Spaces 5 1 1 5 0.06 1 12 15 - DATE Office 107 120 Office Spaces 5 1 1 5 0.06 1 12 15 Reception 190 Reception area 30 6 3 5 0.06 1 26 30 SHEET Conference 190 Conference Room 50 10 SO 5 0.06 1 61 65 MECHANICAL 1,240 179 195 ENERGY FORMS Permit Set DRAWN BY: SEP NOnu DESIGNER: CHLOE MOORE CHECKED BY: CHINS RENSCH SHEET M0.11 GENERAL NOTES (2) KEY NOTES Z_ 1.COORDINATE WITH ELECTRICAL 6.LOCATE HEAT PUMP AT ROOF LEVEL,10 FEET fn CONTRACTOR FOR POWER CONNECTION TO MIN FROM ROOF EDGE.SEE DETAIL FOR �7J IOUm A. ALL IS NEW UNLESS NOTED OTHERWISE. ALL MECHANICAL EQUIPMENT MOUNTING,SIZE AND ROUTE INSULATED ` C REFRIG.LINES FROM ROOF UNIT TO FCU(LINE a w M 2.SIZE TO MATCH UNIT CONNECTION. NOT SHOWN). B. INSULATE DUCTWORK PER CODE AND SPEC REQUIREMENTS(ALL NOT z SHOWN).COORD.CLEARANCE REQUIREMENTS FOR ADDED INSULATION 3..COORDINATE THERMOSTAT LOCATION WITH 7.MOUNT ABOVE CEILING.COORDINATE W/GC w - OWNER,TENANT,OR GENERAL CONTRACTOR FOR SUPPORT AND ACCESS TO UNIT: ul J L 4,PROVIDE A 2-POSITION ISOLATION DAMPER W0 WITH ACTUATOR AS CLOSE AS POSSIBLE TO m ROOF PENETRATION J 5.INSTALL TRAPPED INSULATED TERMINATE — Q CONDENSATE DRAIN IN APPROVED LOCATION. V (� F W V W J T W Iz o Q ° m Y� V_ N - Z z C1 N IZ a M, o Lu aoLu N S Ot WAS AL El HI .I /I /i LLJ 10*0 J i �f a a za. Q 10*0 22z10 NOT IN SCOPE / I� s1 1 �� � ; ) R1 I ; I (SEE(sEE DETAIL)I ' � jLuLu is pm Q. � - Q. I` O I L / wg 27x10� Ri I2 1z 0\I f / �/i// ��� /��j// � ~ z 1 14.0, B 12"0 �'/ 3- TLEI z �, � i. / / //� ��� a 8�0 W >- J n� iCL Ir -.7 _.._ �.1-1�-1�1__L11/ i 0 �---I�-�7-2800 r�-�y�I',�--- — I 2zxlo _....:_B"o L -� E -- -----_ +---- --�- -- --- -----' a -x Q �a 1� .IT EWH-2 - I, r - U 7 -, ro ! �' ` _ C LLL—L", -RT—22z10 -------------- 8"► DATE oamrmn SHEETTITLE (xFER)/ EXISTING SEMI-HEATED WAREHOUSE MECHANICALHVACPAN it Permit Set MECHANICAL HVAC PLAN DR— SEPNDDa NSCALE:I.-1'-0" 0 2' 4' DESIG111 JOHN HNYCHJK CHECKED BY TIM CARR SHEET M2.01 Z COORDINATE CONNECTION ETHOD OF CONNECTION TO C9 20 ga.GALVANIZED SHEET METAL HOOD STRUCTURE IN FIELD AND WITH STRUCT.PLANS(TYP.) HP(AT ROOF OF WAREHOUSE) SHOP FABRICATED SHT.MTL CLG W DIFFUSER CAP,NET INSIDE DIM. BOUND INSUL.STUB DUCT SAME SIZE Z p SAME AS DIFFUSER NECK AS FLEX DUCT HANGER STRAP HOOD AT PIPING — 0 M n FLEX DUCT CLAMP SELF TAPPING SCREWS.. ENE RA UNISTRUT HANGER Ta ROOF MEMBRAPENETRATION NE III Z EQUALIZING GRID PERPENDICULAR TO (SEE DETAIL ON w p STUB DUCT FULL SIZE OF DIFFUSER FLEX DUCT,PULL 81SIDE GALVANIZED MESH THREADED ROD THIS SHEET). J e CAP. HEIGHT FROM DIFFUSER NECK LINER TAUT 45' SCREENING W TO TO STUB CENTERLINE.I FABRICATE PR LOW RE DUCT FROM 229a.PERFERATED SHE MTL 7 (3/16"HOLES ON 1/4"CENTERS) DUCT ` JQ FLASHING,ROOFING AND SEALING � PER ROOFING CONTRACTOR'S FOR DUCTS OVER 48" INSTALL CABLE SEISMIC RESTRAINTS BOTH 19 V 12"MIN REQUIREMENTS WADE,TURN UNDER BOT LONGITUDINALLY AND TRANSVERSELY PER 19 TOP OF ROOF DECK OF DUCT&FASTEN SMACNA REQUIREMENTS Z u CLG DIFFUSER:FASTEN TO CAP W/SHT.MTL SCREWS, DUCT SIZE HANGER SIZE MAX.SPACING W W MIN.ONE PER SIDE SEAL JOINT AIR TIGHT. UP THRU 2 SQ.FT. 1 x 1 16 8-0 NOTES: M ROOF CURB 2 THRU 4 SQ.FT. 1 x 1 8" 8-0" ANGLE FASTNERS p o IYP.SUSP.LAY-IN CEUUNG / I 4 THRU 10 O.FT. 1 x 7 8 6-0" = Z o n 1. PROVIDE SUPPORT FOR DIFFUSER d CAP MOTORIZED DAMPER J I 1 z 1 8 4-0 Q omi PER CODE. DUCT(INTAKE OR EXHAUST) J F Q 2. EQUALIZING GRID REQ'D ON SUPPLY AIR Q �. DIFFUSERS ONLY. INSULATE OUTSIDE PROVIDE NEW SLEEPERS FASTENED AIR INTAKE TO STRUCTURE. 2 Z V 3I LAY- N CLG DIFFUSER a GRILLE n ROOF PENETRATION DETAIL DUC HANGING DETAIL w a (FOR USE IN LIMITED CEILING SPACE) Scale: TUTS L Scale: Nl'S / H P P i P I N G D E T AI L M Scale: TUTS L} W , i Scale: TUTS 2 , H 20 ga.GALVANIZED SHEET IEN METAL HOOD OPENING W/FOAM ! ATION,AIR TIGHT,AFTER s peHWa`- - — ARE INSTALLED �� s ro - CURB GALVANIZED MESH T. I IrZROOF HING,ROOFING AND -r?7 39504�0 SCREENING NG PER ROOFING RACTOR'S REQUIREMENTS .� ll. sS/ONALbN°l OF ROOF DECK UNISTRUT ANCHORED ITO CURB, R CLAMP REFRIGERANT"LINES TO REFRIGERANT LINES - 'UNISTRUT (INSTALL PER CODE) NOTE: THIS ROOFING PENETRATION DETAIL IS TO BE USED FOR REFRIGERANT LINES SERVING CONDENSER AND/OR HEAT PUMPS. 5 REF. PIPING ROOF PENETRATION Elf W Scale: NTS U) Q W � U Z — � > Lu o W it C/) Q- � z a 0 " Z W rn Z. Q F V ?� F a Z a z �o LU �j D 0 Q �a EWSI— SHEETTI LE MECHANICAL DETAILS Permit Set DRAWN BY: eEPMDORI DESIGNER-. GHLOE MOORE D BY CHFUS REMSCH SHEET M5.01 W z G w EQUIPMENT SCHEDULES w z a04 w G SPLIT SYSTEM SCHEDULE J W UNIT INFORMATION COOLING HEATING AIRFLOW POWER SOUND&WEIGHT gQ COOLING STAGES HEATING STAGES TOTAL MIN.VENT ESP MOTOR MCA MOCP SOUND UNIT = a g F TAG DESCRIPTION MANUFACTURER MODEL CPY(BTUH) SEER COOLING CPY(BTUH) COP HSPF HEATING AIRFLOW(CFM) AIRFLOW(CFM) (IN.W.C.) HP VOLTAGE (AMPS) (AMPS) (dBA) WEIGHT(LBS) NOTES F HP SPLITHEATPUMP UNIT ��DAIKIN RXTQ48TAVJU 45500 16 1 49,500 NA 9 NA NA NA NA NA 208/230 1 29.1 1 35 58 176 [1][2][3) V 3 FCU I CONCEALED DUCTED INDOOR UNIT DAWN FXSQ48TAVJU NA NA 1 NA NA NA NA 1,307 918 0.6 NA 1 208/2301 2.8 1 15 42 1 104 [1][2][4] Q a NOTES: [1]COORDINATE FINAL MOUNTING LOCATION WITH BUILDING OWNER W am a 0 [2]MAINTAIN MANUFACTURER'S OF CODE CLEARANCES-WHICH EVER IS GREATER w [3]PROVIDE SLEEPERS FOR MOUNTING AT ROOF-COORDINATE ACTUAL LOCATION WITH G.0 (41 PROVIDE CLEAN I LTERS PRIOR TO HAN D OFF-TO OWN ER BEAL �pp41ER C. ERV SCHEDULE `ay��pF WAS EXHAUST SUPPLY STATIC ERV HEATING TAG DESCRIPTION MANUFACTURER MODEL CFM CFM PRESSURE EFFECTIVENESS SOUND(dBA) VOLTAGE AMP MOP WEIGHT(LB NOTES ERV-1 ENERGY RECOVERY VENTILATOR FAN TECH ATM02DOE 1 195.0 1 195.0 0.4 75%SENSIBLE NA 120/1 1 1.2 NA 57 1][2] 3D304 rsrEs �° NOTES: SsroNALL�O [1]COORDINATE POWER REQUIRMENTS WITH ELECTRICAL CONTRACTOR [2]PROVIDE WITH ECOTOUCH PROGRAMMABLE CONTROL FOR OPERATION WHEN FACILITY IS OCCUPI ED AND OFF WHEN UNOCCUPIED AIR TERMINALS SCHEDULE MARK DESCRIPTION MOUNTING LOCATION MANUFACTURER MODEL NECK SIZE(INCHES) FACE SIZE(INCHES) FINISH NOTES LOUVERED SUPPLY DIFFUSER 4- S-1 T-BAR CEILING SHOEMAKER HVD SEE PLANS 24X24 WHITE FACTORY WAY E-1 E HAUSE BLADE GRILLE W/45° HARD LID SHOEMAKER 905 10X10 12X12 WHITE FACTORY FIXED BLADES W H R-1 RETURN/XFER FIXED 45°BAR T-BAR CEILING SHOEMAKER 915T 22X10 24X12 WHITE FACTORY BLADE GRILLE Q TRANSFER BLADE GRILLE W/45° 2 X-1 FIXED BLADES HARD LID SHOEMAKER 905 10X10 12X12 HITE FACTORY W Z CU W o W EL CONTROLS AND DEVICES SCHEDULE Z OPERATING ~ O TAG DESCRIPTION MANUFACTURER MODEL POWER CONTROLSIGNAL TORQUE NOTES T PROGRAMMABLE THERMOSTAT HONEYWELL TB710DA1000 24VAC CONTACTS NA [1] ~ Wm Lu z MOTORIZED Z ISOLATION DAMPER 2-POSITION ~ z 3 M BELIMO OR EQUAL 24VAC ON/OFF TBD [1][2] ~ w 60 ACTUATOR (ON/OFF) w J G� NOTES: J a � Q �a [1]COORDINATE MO NTING LOCATION WITH GENERAL CONTRACTOR EM.— [2]INTERLOCK DAMPER WITH DOAS UNIT ELECTRIC HEATERS THERMOSTAT TAG DESCRIPTION SERVES MFG. MODEL WATTS CFM TYPE VOLTAGE AMPS NOTES FACTORY EWH-101 WAL-MOUNTED FAN-FOCRED TOILET 109 KING ELECTRIC PAW1215 250.0 2.083 MOUNTED 120/60/1 2.1 [1][21 E ECTRIC WALL HEATER INTEGRAL FACTORY EWH-102 WALL-MOUNTEDFAWFOCRED TOILET110 KING ELECTRIC PAW1215 250.0 2.083 MOUNTED 120/60/1 2.1 [1][2) DATE ELECTRIC WALL HEATER INTEGRAL _ °0.'01rs01 SHEET TITLE NOTES: - 1.COORDINATE POWER CONNECTION WITH ELECTRICAL CONTRACTOR MECHANICAL SCHEDULES Permit Set L� DRAWN BY .Sn DES-ER: CHECKED BY: SHEET M6.01 Permit#: 5404 Permit Date: 06/15/23 Permit Type: COMMERCIAL MECHANICAL Project Name: Service Master Applicant Name: Five Star Mechanical Applicant Address: 7509 Grange St W Applicant, City, State, Zip: Lakewood, WA 98499 Contact: Shane Kovalick Phone: 206-491-1973 Email: shank@fivestarmech.com Scope of Work: Addition of a ducted 4 ton split heat pump with ERV Valuation: 47000.00 Square Feet: 0 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: CIC Permit Issued: 07/18/2023 Permit Expires: 01/14/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP ARLINGTON 301 AP 17216 51 STAVE NE AIRPORT INDUSTRIAL - 31052100400100 SUITE 108 INDUSTRIAL N / MANUFACTURING PARKM QOZB, LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Five Star Mechanical John Ware 206-786-8278 7509 Grange St. CONSTRUCTIONUBI 601 937 083 West CONTRACTOR 7509 Grange St. CONSTRUCTION Labor and Five Star Mechanical John Ware 206-786-8278 West CONTRACTOR Industries FIVESM*OIOJT Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. 09/15/2023 MECHANICAL 09/18/2023 09/18/2023 BUILDING Approved FINAL CIO. Partial 09/06/2023 MECHANICAL 09/06/2023 SafeBuilt ROUGH-IN Approval Plan Reviews Date Review Type Description Assigned To Review Status 06/26/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Processing/Technology $25.00 Air Handling Unit $25.00 Ductwork/Dryer Duct $25.00 Heat Pump-Condensing Unit Enter#of units $25.00 Mechanical Commercial Plan Review Table 4-1 $598.99 Credit Card Service $20.97 Total $719.96 Attached Letters Date Letter Description 07/14/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/18/2023 XBP Con£ $698.99 149476526 07/18/2023 99289496 Raelynn Jones $20.97 Outstanding Balance $0.00 Notes Date Note Created By: 07/18/2023 Emailed that the permit is ready to be picked up. Kristin Foster 06/26/2023 Received hard copies of the plans. Kristin Foster 06/23/2023 Sent follow up email for hard copies. Kristin Foster 06/15/2023 Emailed applicant for submittal documents.Didn't receive any with the application. Kristin Foster 06/15/2023 Received an email from the applicant with electronic copies and confirmation that hard copies Kristin Foster will be dropped off or mailed. Uploaded Files Date File Name 07/18/2023 16189003-20230715 BLD5404 ApprovedPlans.pdf 07/18/2023 16189001-20230718 BLD5404 IssuedPermit.pdf 06/15/2023 15772962-20230615 BLD5404 EquipmentSpecs.pdf 06/15/2023 15772964-20230615 BLD5404 Application.pdf 06/15/2023 15772965-20230615 BLD5404 EnergyCom hp •ance.pdf