Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17216 51st Ave Ne Ste 108_BLD5430_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17216 51ST AVE NE SUITE 108 Permit#:5430 PERMIT EXPIRES 180 DAYS AFTER Parcel#:31052100400100 DATE OF ISSUANCE. Scope of Work:Tenant improvement for Service Master-adding restrooms and Valuation:32100.00 janitors closet OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Bond Plumbing LLC Bond Plumbing,LLC INDUSTRIAL PARKM QOZB,LLC 8201 164TH AVE NW 19023 36th Ave W 1630 215th Street SW REDMOND,WA 98052 Lynnwood,WA 98036 Lynnwood,WA 98036 425-422-3484 206-779-7443 LIC:BONDPPL794MO EXP:07/29/2025 LIC:604 207 260 EXP:01/31/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Bond Plumbing,LLC 1630 215th Street SW Lynnwood,WA 98036 206-779-7443 LIC#: EXP: LIC#:BONDPPL794MO EXP:07/29/2025 JOB DESCRIPTION PERMIT TYPE: COMMERCIAL PLUMBING CODE YEAR: 2018 STORIES: 1 CONST.TYPE: llIB DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The budding official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL,A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 07/18/2023 Applicant Signature Date Building Official Date CONDITIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/18/2023 Plumbing Commercial Plan Review $451.39 07/18/2023 Processing/Technology $25.00 07/18/2023 Plumbing Base $25.00 07/18/2023 Drinking Fountain $15.00 07/18/2023 RoorDrain $45.00 07/18/2023 Kitchen Sink&Disposal $15.00 07/18/2023 Laundry Tray $15.00 07/18/2023 Lavatory $30.00 07/18/2023 Toilets $30.00 07/18/2023 Urinals $30.00 07/18/2023 Water Heater(Tank) $25.00 07/18/2023 Credit Card Service $21.19 Total Due: $727.58 Total Payment: $727.58 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail P COMMERCIAL PLUMBING APPLICATION Community&Economic Development City of Arlington •18204 59th Ave NE•Arlington,WA 98223• Phone (360) 403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This includes commercial, tenant improvements, multi-family buildings, roof drains, and overflows, medical gas systems, commercial kitchens, grease traps and interceptors, sumps and cross connection backflow devices. The City of Arlington does not require a permit to stop leaks or clear stoppages,tuiless the piping is repaired,altered or replaced. SUBMIT ELECTRONIC FILES AND TWO (2) COPIES OF THE FOLLOWING FOR PLAN REVIEW: ❑ Plumbing plans or drawings. (Mininnum plan size is 18"X 24"scale,1/"scale for details.) ❑ Fixture specifications and equipment(cut sheets)with locations. ❑ Location and type of all backflow assemblies for each fixture. IN ADDITION TO ABOVE,SUBMIT TWO(2) COPIES OF THE FOLLOWING,IF APPLICABLE TO YOUR PROJECT: ❑ Calculations for Grease Interceptor. ❑ Pipe size and location of sanitary and potable water systems. ❑ Riser diagram of waste,vent,and rain water systems,including sizes. ❑ Medical gas piping riser diagram,type of gas,storage room and size of piping. Type of Permit: 0 New Installation ❑ Addition/Alteration/Repair ❑ Industrial Property Address: 17216 51th Ave NE Arlington WA 98223 Project Valuation: 32,100.00 Lot#: Parcel ID No.: 51052100400100 Preferred Contact: O Owner 7Contractor Project Description: Tenant improvement for Service Master and adding restrooms, janitors closet, Owner Name: Smartcap AAIP QOZB LLB Office No.: 4254223484 Email Address: markm@pivotal-gc.com Cell No.: 2062517403 Mailing Address: 8201 164th Ave N E City: Redmond State: WA Zip: 98052 Contractor Name: Bond Plumbing LLC Office No.: 4256728281 Email Address: curtis@bondplumbing.net Cell No.: 2067797441 Mailing Address: 19023 36th Ave W City: Lynnwood State: WA Zip: 98036 L&.I Contractor License Number: BON D P P L794M O Expiration Date: 7/29/2023 REV1.2020 Pagel of 3 PLUMBING PERMIT FEES(per fixture Commercial plumbing permits are required to submit line drawings.A plan review fee of 65% per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two(2)inspections with permit. Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = Alteration re pair piping x $15.00 = BackflowAssenibly x $25.00 = Base Plumbing Fee $25.00 $25.00 Bath Shower Combo x $15.00 = Building Main Waste x $25.00 = Clothes Washer x $15.00 = Dishwasher x $15.00 = Drirkng Fountain 1 x $15.00 = 15.00 Floor Drains 3 x $15.00 = 45.00 Grease Interceptor x $75.00 = Grease Trap x $25.00 = Hose Bibb x $15.00 = Iceniaker Refri erator x $15.00 = Irrigation- per meter x $25.00 = Kitchen Sink&Disposal 1 x $15.00 = 15.00 Laundry Tray 1 x $15.00 = 15.00 Lavatory 2 x $15.00 = 30.00 Med Gas Pi in <- 5 inlets outlets x $60.00 = Med Gas Piping> 5 inlets/outlets(plus:5 5 x $5.00 = inlets outlets Miscellaneous- regulated by plumbing x $15.00 = code,not otherwise specified Pretreatment Interceptor x $15.00 = Re-inspection Fee all x $75.00 = Roof Drains x $15.00 = Shower(only) x $15.00 = Sink bar,service,etc. x $ 15.00 = Toilets 2 x $15.00 = 30.00 Urinal 2 x $15.00 = 30.00 Vacuum Breakers x $25.00 = Water Heater 1 x $25.00 LT- Permit 25.00 Water Heater- Tankless x $25.00 Fee 230.00 Table 4-6; Plan Review Fee Processing/Technology Fee $25.00 Total 255.00 REV1.2020 Page 2 of PROPOSED BUILDING USE ❑ New ❑ Restaurant ❑ Automotive Based (3 Addition/Alteration ❑ Office ❑ Machine Shop (3 Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Airwashers ❑ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Ftume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ SwiImImiIlg Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the phumbiug system currently have a grease 0 Yes 43 No ❑ Don't Know interceptor? Does the pltullbing system currently have an oil/water ❑ Yes 4] No ❑ Don't Know separator? Is water used in the business process(washing,rinsing, 0 Yes (3 No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑ Yes C] No ❑ Don't Know I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington. essae ,asaamas=oo s.om Curtis Bond 6/21/2023 Sig.k1LL11 Print Name Date FOR STAFF USE ONLY PERMIT# ACCEPTED BY: DATE STAMP REV1.2020 Page 3 of GENERAL PLUMBING NOTES PLUMBING LEGEND PLUMBING LEGEND 1. THE FOLLOWINGPIPES NOTES APPLY TO ALL PLUMBING DRAWINGS.ADDITIONAL PLUMBING 13. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS 27. PPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM SYMBOL DESCRIPTION SYMBOL DESCRIPTION NOTES MAY BE INDICATED ON EACH PLUMBING DRAWING.SEE SPECIFICATIONS FOR OF PLUMBING EQUIPMENT(VOLTAGES,ETC.). PPE SECTIONS. ADDITIONAL REQUIREMENTS. PIPING GENERAL 14. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY 28. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT HOW PIPING OFFSETS 2. INSTALLATION HALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS WHICH MAY BE REQUIRED. (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, FLOW ARROW CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 26 29. PATCH ALL FLOOR, WALL,CEILING AND ROOF OPENINGS CREATED/CAUSED BY THE NORTH NORTH ARROW O SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL ELECTRICAL PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY DEMOLITION OF EXISTING PIPES, FIXTURES, ETC. IN ACCORDANCE WITH DIVISION 1 Imo- CAP OR CLEANOUT TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH SERVE EQUIPMENT. OF THE SPECIFICATIONS. CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. 0- PIPE UP OR TEE UP AND DOWN 15. SECURE WATER HEATERS AND STORAGE TANKS AND PLUMBING EQUIPMENT TO 30. ALL WATER PIPING IN UNHEATED SPACES EXCEPT CIRCULATED HOT WATER SHALL SECTION IDENTIFICATION 3. INSTALL ALL WASTE LINE CLEANOUTS IN ACCORDANCE NTH CHAPTER SEVEN OF STRUCTURE AS REQUIRED BY CODE. REFER TO THE STRUCTURAL DRAWINGS FOR BE HEAT TRACED AND INSULATED. C PIPE DOWN A THE UNIFORM PLUMBING CODE: ADDITIONAL SPECIAL REQUIREMENTS RELATED TO THE PLUMBING INSTALLATION. LIA M201 A.3"WASTE PIPE-3"CLEANOUT WITH 2.5"PLUG 31. WHERE PIPE SIZES ARE NOT SHOWN ON DRAWINGS,SIZE PIPING PER THE UNIFORM � PIPE TEE UP B.4"WASTE PIPE- e CLEANOUT WITH 3.5°PLUG 16. PROVIDE PLUMBING ANCHORAGE AND EXPANSION EVERY 100' PIPE LENGTH PER PLUMBING CODE. SHEET IDENTIFICATION C.6"WASTE PIPE-4"CLEANOUT WITH 3.5°PLUG CODE. PIPE TEE DOWN 32. PRIOR TO SUBMITTING ALL PLUMBING FIXTURES THE CONTRACTOR SHALL VERIFY 4. WASTE,VENT AND SUPPLY PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SHALL 17. ACCESS PANELS ARE REQUIRED AT ALL CONCEALED VALVES AND EQUIPMENT. COMPATIBILITY OF THE SPECIFIED FIXTURE WITH THE SIZES OF FINISH CABINETRY 45'DEGREE ELBOW O SHEET NOTES BE AS SHOWN ON PLUMBING FIXTURE SCHEDULES.BELOW GRADE SANITARY WASTE COORDINATE LOCATION AND SIZE WITH ARCHITECT. AS IDENTIFIED IN GENERAL CONTRACTOR'S SHOP DRAWINGS. ANY DISCREPANCIES HV Engineering,Inc. PIPING SIZES SHALL BE AS SHOWN ON PLANS AND FIXTURE SCHEDULES AND BETWEEN THE SIZE OF THE FIXTURES SPECIFIED AND THE FINISH CABINETRY SIZES L 90'DEGREE ELBOW O (RISER it on RISER CALLOUT csulting Engln- SHALL NOT BE LESS THAN 2"DIAMETER. 18. STUB OUT TO SITE SERVICES 5' OUTSIDE BUILDING FOUNDATION. PIPE SIZE, SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE Hall Creek Office Park FIXTURE UNITS,AREA DRAINED, INVERT ELEVATION, SIZES,AND SQUARE FOOTAGES SUBMITTAL. 4 WAY TEE C 6912 220th St.SW,Suite 303 5. ALL SANITARY SEWER PIPING BELOW SLAB SHALL BE INSTALLED AT A MINIMUM OF AS INDICATED. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING a PLUMBING FIXTURE TAG(WC11 Mountlake Terrace,WA 98043 1/4° PER FT SLOPE UNLESS APPROVAL IS PROVIDED BY THE "ADMINISTRATIVE WORK. 33. PLUMBING VENTS SHALL TERMINATE A MINIMUM 10' FROM OUTSIDE AIR INTAKES, AUTHORITY" IN WRITING FOR A SHALLOWER SLOPE. IN NO CASES SHALL SEWER PER CODE. TEE Phone:(206)706-9669 PIPING BE INSTALLED AT LESS THAN 1/8" PER FT SLOPE. IN NO CASES WILL 19• INSULATE PIPING PER WSEC AND PER DIVISION 22 SPECIFICATIONS(WHICHEVER IS zi, REVISION CALLOUT(REV-1) w hNongineenno.ol� PIPING SMALLER THAN 4" BE INSTALLED AT SLOPES SHALLOWER THAN 1/4" PER GREATER). 34. LABEL ALL PIPING SYSTEMS PER THE IMC AND UPC. PIPE BREAK ''^-�j FOOT. PIPING INSTALLED AT 1/8-/FT HALL BE RESIZED PER CHAPTER 7 OF THE 20. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW 35. SUPPORT AND BRACE PIPING SYSTEMS IN ACCORDANCE WITH UPC SECTION 314 `-N._.-N-'" REVISION BUBBLE UNIFORM PLUMBING CODE AND SUPPORTING CALCULATION SUBMITTED TO ENGINEER DUCTWORK AND BETWEEN LIGHT FIXTURES.ADJUST AS NECESSARY. AND AS REQUIRED IN THE SPECIFICATIONS. FOR REVIEW. PIPING SPECIALTIES 21. PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM 36. ALL MATERIALS IN CONTACT NTH PIPING SYSTEMS HALL BE COMPATIBLE FOR X DETAIL CALLOUT(X/PX.XX) Project 6. PROVIDE STOPS PRIOR TO ALL PLUMBING EQUIPMENT. THIS SHALL ALSO INCLUDE USE WITH AND FOR CONTACT WITH THE PIPING MATERIAL. CONTRACTORS AND PROVIDING INTEGRAL STOPS ON ALL SHOWER AND TUB/SHOWER VALVES(WHETHER ACCESS OF 6° IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18" TO TRADES SHALL VERIFY COMPATIBILITY OF THEIR PRODUCTS WITH THE PIPING PRESSURE GAGE TENANT IMPROVEMENT: THE SIDE OF CABLE TRAYS. SERVICE MASTERS SPECIFIED OR NOT). PROVIDE WASTE TRAPS AT ALL DIRECT CONNECTED SYSTEMS.THIS INCLUDES,BUT IS NOT LIMITED T0,FIRE STOPPING SEALANTS,FIRE �- � COLUMN GRID SYMBOLS EQUIPMENT IN ACCORDANCE WITH CODE AND THE SPECIFICATIONS. 22. COORDINATE LOCATIONS OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES OVER STOPPING COLLARS, VIBRATION ISOLATION ELEMENTS, THERMAL INSULATION, _+ LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT EXPANSION JOINTS AND ANY MATERIAL IN CONTACT WITH PIPES. THERMOMETER A - 7. PROVIDE TRAP PRIMERS AT ALL FLOOR DRAINS UNLESS NOTED OTHERWISE. MAINTENANCE. Location PROVIDE UNION ON UPSTREAM AND DOWNSTREAM SIDE OF ALL TRAP PRIMERS. 37. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE �-SIGHT GLASS 6 TRAP PRIMER BRANCH TAKEOFF SHALL BE FROM TOP OF MAIN DISTRIBUTION PIPE. 23. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY FLOORPLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE NSF INTERNATIONAL ���VENTURI FLOW METER O GENERAL MECHANICAL NOTES 17216 51 st Ave NE, 8. INSULATE P-TRAPS EXPOSED IN UNHEATED SPACES. ROUTING ONLY. NUMBER IDENTIFICATION Industrial Park,Building B 38. PIPE BURIAL METHODS FOR BELOW GRADE PIPING SHALL COMPLY WITH MFR 9. SEE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE ROUGH-IN DIMENSIONS 24. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY INSTALLATION INSTRUCTIONS,ASTM D 2321 AND ASTM F1668. FAILURE TO FOLLOW ROW METER FLAG MECHANICAL NOTES Arlington,WA 98223 AND OTHER DETAILS. ALSO SEE ARCHITECTURAL DRAWINGS FOR FINISH ' THESE REQUIREMENTS CAN LEAD TO PIPE FAILURE. NUMBER IDENTIFICATION REQUIREMENTS N ALL PLUMBING FIXTURES INCLUDING REQUIREMENTS S MANUFACTURERS INSTALLATION INSTRUCTIONS,AS INDICATED ON DRAWINGS,OR IN FLUSH SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL -� Prepared For LEVER LOCATION AT AD COMPLIANT TOILETS AND VALVE LOCATIONS OF ADA MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN 39. ROOF MOUNTED PIPING SHALL BE INSTALLED ON FREE FLOATING, PREFABRICATED MANUAL AIR VENT(MAV) EXISTING WORK OR BACKGROUND p SHOWERS.REPORT ALL DISCREPANCIES TO ENGINEER PRIOR TO ANY WORK. INSTITUTE OF STEEL CONSTRUCTION(AISC)MANUAL SUPPORTS SIMILAR TO MIRO MODEL 24-R OR ROOF TOP BLOX ON WALKWAY INFORMATION(LIGHT UNE NEW WORK (HEAVY LINE; Bond Plumbing, LLC 10. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE PLUMBING TREAD PADS.THE USE OF WOOD FOR SUPPORTS IS PROHIBITED. �GAS PRESSURE REGULATOR R 25. IF REQUIRED FOR INSTALLATION OF PIPES AND EQUIPMENT, PROVIDE ADDITIONAL RELOCATE EXISTING EQUIPMENT ITEM FIXTURES AT HEIGHTS SHOWN ON ARCHITECTURAL ROOM ELEVATIONS. 40. ALL ITEMS IN CONTACT WITH POTABLE WATER SHALL COMPLY WITH THE NATIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO "REDUCTION OF LEAD IN DRINKING WATER ACT"5.3874. MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL - �WATER METER OR DEVICE INDICATED 11. PLUMBING DRAWINGS SHOW APPROXIMATE LOCATIONS OF PLUMBING FIXTURES. 19023 36th Ave W.Suite G REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. COORDINATE FLOOR MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. EXISTING EQUIPMENT OR PIPING DRAINS FOR MECHANICAL SPACES WITH MECHANICAL EQUIPMENT BEING SERVED. ---- � WYE STAINER TO BE SELECTIVELY DEMOLISHED Lynnwood,WA 98036 26. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, PMP-1 12. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE CONSTRUCTION INCLUDING CONCRETE EQUIPMENT PADS,FLASHING DETAILS,ETC. STRUCTURAL ENGINEER. WYE STAINER NTH CAPPED HOSE END BLOWUOWN VALVE TYPICAL EQUIPMENT DESIGNATION (PUMP) -{�- FLANGE -i F-- UNION POINT OF CONNECTION TO EXISTING THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND ABBREVIATIONS ECCENTRIC REDUCER PLUMBING,LLC ON A DESIGN BUILD WATER PIPING SYSTEMS CONCEPT.THEY ARE TO BE USED ONLY AAV AIR ADMITTANCE VALVE EA EACH HWS HOT WATER HEATING SUPPLY OC ON CENTER SHT SHEET STEAM TRAP WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION AC AIR CONDITIONING EAT ENTERING AIR TEMPERATURE HWR HOT WATER HEATING RETURN OSA OUTSIDE AIR SP STATIC PRESSURE WS WATER SERVICE CONTACT: CURTIS BOND. ABV ABOVE ECC ECCENTRIC IA INSTRUMENT AIR OAT OUTSIDE AIR TEMPERATURE SPEC SPECIFICATION HOSE BIBBS COLD WATER FILTERED AD ACCESS DOOR ECON ECONOMIZER ID INSIDE DIMENSION GA OUTSIDE AIR SQ SQUARE NO. DATE REWSION AFC ABOVE FINISHED CEILING EER ENERGY EFFICIENCY RATIO IE INVERT ELEVATION OD OUTSIDE DIMENSION SR SUPPLY REGISTER HOSE BIBB/WALL HYDRANT - COD WATER(ABOVE FLOOR/GRADE) AFF ABOVE FINISHED FLOOR EF EXHAUST FAN IH INSULATION HOT OPP OPPOSITE SS STAINLESS STEEL WATER(ABOVE FLOOR/GRADE) AEG ABOVE FINISHED GRADE EFF EFFICIENT,EFFICIENCY IN INCH,INCHES OV OUTLET VELOCITY SYS SYSTEM ��PIPE ANCHOR -- HOT HOT F TEMPERED WATER IF NOT AFUE ANNUALIZED FUEL EFFICIENCY EG EXHAUST GRILLE INFO INFORMATION OCP OVER CURRENT PROTECTION STAT THERMOSTAT ��ALLIGNMENT GUIDE INDICATED OTHERWISE) AHU AIR HANDLING UNIT EL ELEVATION INST INSTRUMENT OU OUTDOOR UNIT AL ALUMINUM ELEC ELECTRICAL INSUL INSULATE,INSULATION TEMP TEMPERATURE �TS TEMPERATURE/PRESSURE 140 HIGH TEMP HOT WATER 140' APPROX APPROXIMATELY EQUIP EQUIPMENT INV INVERT P PUMP TD TEMPERATURE DIFFERENTIAL TEST PORT/PETE'S PLUG OR AS INDICATED ARCH ARCHITECTURAL ET ELECTRIC TRACED IRR IRRIGATION(NON POTABLE) PD PRESSURE DROP TDH TOTAL DYNAMIC HEAD FLEXIBLE CONNECTION IN PIPING T TEMPERED WATER ATMOS ATMOSPHERE EXIST,(E)EXISTING IU INDOOR UNIT PERF PERFORATED TEMP TEMPORARY EXH EXHAUST PF PRE FILTER THRU THROUGH FUNNEL --- HOT WATER CIRCULATING BATT BATTERY E%T EXTERIOR JAN JANITOR PH PHASE TI TENANT IMPROVEMENT Y GOD BACK DRAFT DAMPER Pi PUSH ON JOINTS TSTAT THERMOSTAT NP NON POTABLE WATER BF BFC BEIND LOWFFINII FINISHED CEILING FD FIREGE F RENHEIT KW KILOWATT DAMPER OR FLOOR DRAIN KWH KILOWATT HOUR PNLS PANELS TYP TYPICAL TRU TERMINAL REHEAT UNIT VALVES WATER METER BHP BRAKE HORSE POWER FF FINISHED FLOOR LAT LEAVING AIR TEMPERATURE POC POINT OF CONNECTION XI>61WWWY HEAT TRACE FOR COLD WATER PIPE PARTNER IN CHARGE BI BACKWARD INCLINED FLGD FLANGED PRV PRESSURE REDUCING VALVE UL UNDERWRITER'S LABORATORY 0 BALANCING VALVE SB BLDG BUILDING FUR FLOOR LEIS POUND PS PIPE SUPPORT UNO UNLESS NOTED OTHERWISE PROJECT MANAGER BOD BOTTOM OF DUCT FCO FLOOR CLEAN OUT LC LOCKED CLOSED PSV PRESSURE SAFETY(RELIEF) UV UNIT VENTILATOR PRESSURE REGULATING VALVE DRAIN WASTE & VENT PIPING DJ BTU BRITISH THERMAL UNIT FPM FEET PER MINUTE LF LINEAL FEET VALVE I UNIFORM MECHANICAL CODE BTUH BRITISH THERMAL UNIT PER FLTR FILTER LOC LOCATION UP UNIFORM PLUMBING CODE �P WASTE(ABOVE FLOOR)PIPING PROJECT ENGINEER HOUR QTY QUANTITY PRESSURE REDUCING VALVE(PRV) BQ FOF FACE OF FLANGE LL LANDLORD UBC UNIFORM BUILDING CODE - FPI FINS PER INCH _VG LEAVING UPC UNIFORM PLUMBING CODE AUTOMATIC CONTROL VALVE-TWO WAY WASTE(BELOW FLOOR)PIPING PROJECT TEAM MEMBERS CFM CUBIC FEET PER MINUTE R RELIEF FSK FOIL SKRIM KRAFT LINED DUCT UG UNDERGROUND (ELECTRIC OPERATOR SHOWN) JM CHAR CHARACTERISTICS (SPUNSTRAND) MATL MATERIAL RA RETURN AIR ----------------VENT CHECK CHEM CHEMICAL INJECTION FT FEET,FOOT RED REDUCER BQ CHWS CHILLED WATER SUPPLY MA MED GAS V VOLT FU FIXTURE UNITS MA% MAXIMUM READ REQUIRED VAC VOLTS AC AUTOMATIC CONTROL VALVE-THREE WAY AW ACID WAS1E CHWR CHILLED WATER RETURN FV FACE VELOCITY MPG MEDIUM PRESSURE GAS RR REMOVE AND RELOCATE VDC VOLTS DC (ELECTRIC OPERATOR SHOWN) GW GREASE WASTE ENGINE! CLG CEILING FW FEED WATER RJ RESTRAINED JOINTS CO CLEAN OUT MA MIXED AIR VD VOLUME DAMPER BALL VALVE GD GARAGE DRAIN FPTU FAN POWERED TERMINAL UNIT MBH THOUSAND BRITISH THERMAL RET RETURN VAC VACUUM � CONC CONCRETE UNITS PER HOUR RG RETURN GRILLE C CONDENSATE DRAIN CONN CONNECT OR CONNECTION A VAV VARIABLE AIR VOLUME ��GATE VALVE G GAS MCC MOTOR CONTROL CENTER RPM REVOLUTIONS PER MINUTE VEL VELOCITY P PUMPED PIPING of 1LAsy CPLG COUPLING GALV GALVANIZED MCA MAXIMUM CIRCUIT AMPS RWL RAINWATER LEADER VF VENTILATION FAN GAS COCK CS CARBON STEEL GEN GENERATOR MAT MIXED AIR TEMPERATURE VFD VARIABLE FREQUENCY DRIVE ------0 FCO FLOOR CLEANOUT(FCO) - t CSC CARSEALED CLOSED GFl GROUND FAULT MAX MAXIMUM SS SANITARY SEWER VTR VENT THROUGH ROOF RELIEF VALVE WCO WALL CLEANOUT(WCO) " CSO CARSEALED OPEN CIRCUIT INTERRUPTER MECH MECHANICAL STAINLESS STEEL VOL VOLUME CHECK VALVE O VIR VENT THRU ROOF S CV CONSTANT VOLUME GR GRILLE MFR MANUFACTURER SA SUPPLY AIR �� TsrER`� r V/PH/HZ VOLTS/PHASE/HERTZ ® FLOOR DRAIN CW COLD WATER GPM GALLONS PER MINUTE MED MEDIUM SCHED SCHEDULE 1�BUTTERFLY VALVE TONAL�' CRD CEILING RADIATION DAMPER GV GATE VALVE MH MANHOLE SECT SECTION q� 0 FLOOR SINK 6/15/2023 GW GRAY WATER(NON POTABLE) MIN MINIMUM,MINUTE SEER SEASONAL ENERGY EFF.RATIO W/ WITH REDUCED PRESSURE BACKFLOW ASSEMBLY DET DETAIL MISC MISCELLANEOUS SVc SERVICE W/0 WITHOUT DFU DRAINAGE FIXTURE UNITS GWR GLYCOL WATER RETURN TITLE GINS GLYCOL WATER SUPPLY MV MED VACUM SHT SHEET W WASTE � BALANCING/MEASURING VALVE SHEET INDEX DIA DIAMETER SO SMOKE DETECTOR We WET BULB SHEET TITLE W PLUMBING COVER SHEET DIM DIMENSION HP HORSE POWER N NORTH,NEUTRAL SL SOUND LINING WC WATER CLOSET PO.01 PLUMBING COVER SHEET DISCH DISCHARGE HPFS HIGH POINT FINISHED SURFACE NA NOT APPLICABLE SV SOLENOID VALVE WCO WALL CLEAN OUT REFERENCE CODES PO.02 PLUMBING SCHEDULES DI DUCTILE IRON HR HOUR NC NORMALLY CLOSED SW SOCKET WELD WG WATER GAUGE P1.00 UNDERGROUND PLUMBING PLAN DMPR DAMPER NIC NOT IN CONTRACT STA STATION WHA WATER HAMMER ARRESTER IBC INTERNATIONAL BUILDING CODE-2018 P1.01 UNDERGROUND ENLARGED PLANS HTG HEATING WT WATER TANK IMC INTERNATIONAL MECHANICAL CODE-2018 P2.00 LEVEL 1 PLUMBING PLAN PROJECT ND. DN DOWN HT HEIGHT NO NUMBER OR NORMALLY OPEN STD STANDARD UPC UNIFORM PLUMBING CODE-2018 DP DIFFERENTIAL PRESSURE HVAC HEATING VENTILATION AND AIR NG NATURAL GAS SF SUPPLY FAN WT WEIGHT IFGC INTERNATIONAL FUEL GAS CODE-2018 P2.01 LEVEL 1 ENLARGED PLANS �y 2023-051 DR DRAIN CONDITIONING NTS NOT TO SCALE SFD SMOKE/FIRE DAMPER l W WATER IFC INTERNATIONAL FIRE CODE-2018 P3.00 PLUMBING DETAILS I'1r DATE DUNE 15,2023 DWG DRAWING HW HOT WATER S.I.O. NSTALLED BY NEC NATIONAL ELECTRICAL CODE-2017 P4.00 ISOMETRIC RISER DIAGRAMS W PROJECT NETWORK PATH HWC HOT WATER CIRCULATING 02 OXYGEN .I.O. OWNER/OTHER WSEC WASHINGTON STATE ENERGY CODE ADA AMERICAN DISABILITY ACT STANDARDS-2010 ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS- A17.1 -2007 W/2008 ADDENDA SAFETY CODE FOR REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER ELEVATORS AND ESCALATORS O O NFPA NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING 13D,13R,OR 13(AS APPLICABLE)-2016 HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„-t„ ■ THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. PLUMBING CALCULATIONS 2018 UNIFORM PLUMBING CODE PER TABLE 702.1 AND TABLE A-2.1 BUILDING SUMMARY MIN.SIZE DOMESTIC WATER SEWER DFU DOMESTIC WATER O TRAP/ARM PER HWPER PER TOTAL PER - HOT WATER PIPE SIZING TABLE COMMERCIAL ENERGY EFFICIENCY TABLE C404.3.1 FIXTURE TYPE IN. OTV FIXTURE TOTAL FIXTURE HW FIXTURE TOTAL WSFU BASED ON 2018 UPC CHART A2.1 REFRIGERATOR FOUNTAIN,ECTERCOOLER ASSEMBLY 1.25 1 1 1 -- - 1 1 pIpEMATERIAL TABLE C403.10.3 PIPING VOLUME & MAXIMUM REFRIGERATOR CONNECTION -- 1 1 1 - - 0 0 TYPE L COPPER FLOOR DRAIN-EMERGENCY 2 1 2 -- -- -- -- 0 0 MINIMUM PIPE INSULATION THICKNESS(in.)[a] PIPE LENGTHS SINKS -- - -- -- -- LAVATORY,SINGLE 1.25 2 1 2 0.75 1.5 1 2 FLUSH TANK - -- - VELOCITY<=BFPS FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE(in.) TEMPERATURE VOLUME MAXIMUM PIPING LENGTH(FT.) SPECIAL PURPOSE 3 1 3 3 2.25 2.25 3 3 RANGE AND CONDUCTIVITY MEAN RATING NOMINAL PIPE (FL.OZ.PER KITCHEN,DOMESTIC(2"DRAIN) 1.5 1 1.5 1.5 1.125 1.125 2 2 PSII100 FT 8 { <t 1 TO<tY2 1Y2 TO<4 4 TO<8 x8 SIZE(IN.) PUBLIC LAV OTHER SERVICE OR MOP BASIN-PUBLIC 2 OR 3 0 3 2.25d4.875 3 0 WSFU RANGE MIN MAX USAGE(F) Btu-in/(h ft"2•T)[b] TEMPERATURE,F FOOT LENGTH) FAUCETS FIXTURES/APPLIANCES URINALS -- -- -- -- -- -- _ PIPE SIZE") 105-140 0.21 -0.28 100 1.0 1.0 1.5 1.5 1.5 J¢" 1.5 2.0 43.0 PRIVATE,1 GPF,FLUSHOMETER,.75"SUPPLY 2 2 4 8 2 4 1/2 0 4 40-60 0.21 -0.27 75 0.5 0.5 1.0 1.0 1.0 y4" 3.0 0.5 21.0 WATER CLOSETS -- -- -- -- _ -- - 3/4 4.5 11 <40 0.20-o.2s 50 0.5 t.o t.o t.o t.5 HV Engineering,Inc. 1.6 GPF FLUSHOMETER VALVE,PUBLIC 3 2 5 10 -- 4 8 1 12 22 1" $.Q 0.$ 13.D TOTALS 12 26.5 20 11/4 23 50 [a] FOR PIPING SMALLER THAN IY2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, 1Ya" 8.0 0.5 8.0 1 uz 51 100 REDUCTION OF THESE THICKNESSES SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN Consulting Engineers 2 101 265 FOOTNOTE[b]BUT NOT TO A THICKNESS LESS THAN 1 INCH. FL 11.0 0.5 6.0 Hall Creek Office Park COPYRIGHT HV ENGINEERING b FOR INSULATION OUTSIDE THE SLATED CONDUCTIVITY RANGE,THE MINIMUM THICKNESS SHALL BE 2"AND LARGER 18.0 0.5 4.0 Mountlake flake220t St.SW,Suite 303 [] (� Mountlake Terrace,WA 98043 DETERMINED AS FOLLOWS: Phone:(206>7os-9ss9 2018 UPC APPENDIX A WATER SERVICE CALCULATIONS PIPE MATERIAL �" w one:(206)70-96 biz Coldwater Iping to 2e ase on a FV System(FV=Flush Valve,FT=Flush Tank) TYPE L COPPER T=rl(1 +t/r)�(Ky n)-1) Hot Water Piping to be Sized Based on a FT System(FV=Flush Valve,FT=Flush Tank) FLUSH TANK PIPE MAINS FIX UNIT GPM SIZE VELOCITY<=SFPS WHERE: COLD WATER 26.500 38 SEE PLANS T=MINIMUM INSULATION THICKNESS HOT WATER1 4.875 1 3 1 SEE PLANS PS11100 FT 8 r=ACTUAL OUTSIDE RADIUS OF PIPE WSFU RANGE MIN MAx t=INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE Project BLDG SUPPLY PRESSURE(PSI): 7z.o PIPE SIZE" K=CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE PIPE LOSS BETWEEN BUILDING AND TENANT SPACE(PSI): 22.0 AVERAGE4 PSI/100'AT 530 FEET 1/2 0 4 APPLICABLE FLUID TEMPERATURE(Btu•in/h*ft"2*'F) TENANT IMPROVEMENT: SUPPLY PRESSURE FOR PIPE SIZING TENANT(PSI): 50.0 3/4 a.5 9 k=THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID SERVICE MASTERS 1 m 1s TEMPERATURE. COLD WATER PRESSURE LOSS: 1 114 17 zs [c] FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING,REDUCTION OF THESE THICKNESSES BY 1Y22 ELEVATION CHANGE(PSI) 4.3 1 10 FEET AT 0.433 PSI/FT COPYRIGHT HV ENGINEERING INCHES(38mm)SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE[b]BUT Location MIN.RESIDUAL PRESS.AT REMOTE FIXT.(PSI) 30.0 (TYPICALLY PROVIDE 25 PSIG+5 PSIG FOR TXV) NOT TO THICKNESSES LESS THAN 1 INCH(25mm)). TOTAL PRESSURE LOSS: 34.3 PIPE MATERIAL TYPE L COPPER 17216 51 st Ave NE, 780 FLUSH VALVE 34.3 VELOCITY Industrial Park,Building B AVAILABLE PRESSURE(PSI) 43.7 Arlington,WA 98223 PSV100 FT 8 LONGEST PIPE RUN WITHIN TI(FT) 90.0 43.67 X 100 FT WSFU RANGE MIN MAX Prepared For X 1.25(FITTINGS) 1.25 112.5 113 FT PIPE SIZE(") 0 3.25 Friction Loss Not to Exceed 38.8 PSI/100FT LOSS 11/4 4.25 12 Bond Plumbing, LLC Size All Piping Based on a Friction loss of:Og PSI/100FT LOSS 1 1/2 13 35 and max velocity based on installation standard. 2 36 135 21/2 DESIGN MAX F 136 345T COPYRIGHT HV ENGINEERING 19023 36th Ave W.Suite G SIZE MAINS AND RISERS PER BELOW PSIAOOFT LOSS PER APPL. Lynnwood,WA 98036 MAIN%LENGTH OF TOTAL PIPE 90Y 8 101 RISERS/UNIT PIPING LENGTH OF TOTAL PIPE 10°h 8 11 TOTAL ALLOWABLE PSIG FRICTION LOSS 43.7 ACTUAL TOTAL FRICTION LOSS 9.0 SAFETY FACTOR PSIG,MUST BE POSITIVE NUMBER 34.7 NOTE,CALCS CONSERVATIVE BECAUSE NO CREDIT IS TAKEN THESE DRAWINGS WERE DEVELOPED FOR LOWER THAN MAX FLOW RATES IN EACH PIPE SECTION. FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION PLUMBING FIXTURE SCHEDULE ELECTRIC WATER HEATER SCHEDULE PUMPS EXPANSION TANKS CONTACT: CURTIS BOND. NO. DATE REVISION SYMBOL REM WASTE VENT CW HW SPECIFICATION REMARKS MARK NUMBER CP-1 WC-1A WATER CLOSET-FLUSH VALVE(ADA) 3 2 1 - SEE CONTRACTOR'S SUBMITTALS 1.28 GPF EQUIPMENT NUMBER WH-1 SERVICE EQUIPMENT NUMBER ET-1 LOCATION BREAK 108 UR-1A URINAL(ADA) 2 1-112 314 - SEE CONTRACTOR'S SUBMITTALS 1.0 GPF UNIT LOCATION BREAK 108 AREA SERVICE LOCATION BREAK 108 SY STEM 120 DEG SYSTEM SERVED DOMESTIC HOT WATER DOMESTIC SYSTEM DOMESTIC HW L-IA LAVATORY(ADA) 1-1/2 1-1/2 1/2 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM TYPE CARTRIDGE TYPE COUNTER MOUNTED TypE TANK HEATER SERVICE CONDITIONS ORIENTATION VERTICAL 8-1 BREAK ROOM SINK 2 1-1/2 112 1/2 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM LINING YES CAPACITY-GPM 2 ASME NO CAPACITY-GALLONS 28 TOTAL HEAD-FT 15 SERVICE CONDITIONS S-2 UTILITY SINK 3 1-1/2 1/2 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM RECOVERY(GPH 90 DEG RISE 21 FLUID WATER CAPACITY-GALLONS 6A SERVICE CONDITIONS I TEMPERATURE-DEG F 140 DEG F ACCEPTANCE-GALLONS 3.2 IM-1 REFERIGERATOR ICE MAKER CONNECTION 1/2 SEE CONTRACTOR'S SUBMITTALS LVG WATER TEMP-DEGF 140 UNIT CONDITIONS INSULATION NA ENERGY FACTOR SPEED-RPM 3250 FLUID WATER ELECTRICAL CONNECTIONS INLEVOUTLET 3/4"SWEAT PRESSURE-PSI 150 PARTNER IN CHARGE DFAA DRINKING FOUNTAIN 1-1/2 1-M 1/2 - SEE CONTRACTOR'S SUBMITTALS NUMBER OF STAGES 1 MOTOR TEMPERATURE-DEGF 140 SB DUAL HEIGHT(ADA) KW INPUT/STAGE 4.5 ENCLOSURE TYPE UNIT CONDITIONS PROJECT MANAGER 611412023 NOTE 1-COORDINATE FINAL FIXTURE SELECTION WITH OWNER PRIOR TO PROCUREMENT TOTAL KW 4.5 HORSEPOWER-MINIMUM 1/25 INLET&OUTLET TAP SIZE 3/4" DJ VOLTS-PHASE-HERTZ 240/l/60 SPEED-RPM 3250 WEIGHT FULL 26 PROJECT ENGINEER NOTES [1],[2],[3] VOLTS-PHASE-HERTZ 11 250/1 DIAMETER AND HEIGHT 12"x18" MISCELLANEOUS PLUMBING EQUIPMENT SCHEDULE MANUFACTURER-DESIGN BASIS AMTROL ST-12 BQ MANUFACTURER-DESIGN BASIS MANUFACTURER-DESIGN BASIS TACO 008-BRONZE PROJECT TEAM MEMBERS ID DESCRIPTION MAKEIMODEL CERTIFICATIONS REMARKS MAKE RHEEM NOTES [11 REMARKS JM FD-1(E) FLOOR DRAIN(FD) SEE CONTRACTOR'S SUBMITTALS MEDIUM DUN.B-1l2"ROUND CAST IRON GRATE.PIPE SIZE PER PLAN. MODEL XE28S06ST45U0 REMARKS 6/15/2023 CHECK EMERGENCY ONLY I SIZE WEIGHT FULL/DIAMETER/HEIGHT 303#/23"x30" 111 PROVIDE TIMER/AQUASTAT BQ FCO FLOOR CLEANOUT SEE CONTRACTOR'S SUBMITTALS REMARKS 6/2/2023 [11 MOUNT IN CABINET TMV-1 MIXING VALVE SEE CONTRACTOR'S SUBMITTALS ABBE 1070 POINT OF USE AT LAYS [21 PROVIDE SEISMIC STRAPS. ENGINEERS SEAL [3] WEIGHT=OPERATING WEIGHT TP-1 TRAP PRIMER SEE CONTRACTOR'S SUBMITTALS PRESSURE ACTIVATED 6/5/2023 3i WASy 6/6/2023 2 PIPING SYSTEM AND SPECIFICATION SCHEDULE rM� SYSTEM LOCATION MATERIAL JOINT METHOD REMARKS/PIPE INSULATION 6/15/2023 WASTE&VENT BELOW GROUND SCH.40 PVC(SOLID CORE) SOLVENT WELD DOMESTIC WATER BELOW GROUND COPPER TYPE K BRAZE DOMESTIC WATER BELOW GROUND PEX EXPANSION COUPLING `w^ TITLE SCHEDULES WASTE&VENT ABOVEGROUND PVC-SCHEDULE 40 SOLVENT WELD U) DOMESTIC WATER 2"&SMALLER ABOVE GROUND COPPER TYPE L SOLDER OR PROPRESS INSULATE PER WSEC NOTES: 1.RECIRC LOOP MUST BE INSULATED PER ESDS AND WASHINGTON STATE ENERGY CODE,WHICHEVER IS GREATER. PROJECT 10. 2023-051 DATE JUNE 15,2023 W PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ;H O.O L A THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. 42> 2 3 4 5 6 7 8 O 3"WATE SERVI E f 9 TO W TER MAI 0 [ O DOMESTIC WATER METE - 1 O PER CITY STANDARD ' 40SF. 6"RL 6"RL "CW SE (6890S.F.) 3/a'CW IU i O. ...9.44 S.F....................... ... .....................'..................... ..,0 �9400S.F.) .,C TO O T RPB o o - o — o o P To FD 1-�o- 'Cw u = HV Engineering,Inc. ----- -�' ----- - - -------------+------ -- - - - --- ----�---- -------- 1' 2 V UP 1 CW-- - - - - -- —'— __ __ Z Consulting Engineers Hall Creek Office Park _ POUR STRIP --- 4"W UP TO HD—I I 6912 220th St.SW Suite 303 V—UP_—.—_—_ -NI N Mountlake Terrace,WA 98043 •~ _ I Phone:(206)706-9669 2„ iwww.hvengineering.biz g - - BELOW FINISHED FI - FCC FCO FCO FCO FCO F FCO P OOR, TYPICAL FCO FCO _ _ ,_____b o _ o- 4 P ___ ______ � ____. _ _ _ _ _____ _______________� ^y ^I Project 80'-4" 1 n4'-2' I P1.01 TENANT IMPROVEMENT: I18 10 I I I SERVICE MASTERS J HIT srDe, TYPICAL s 7 --------- ------ ------ ------ ---- � I Location 4"W UP TO FLOOR CLEAN OUT FOR FUTURE TEN II i I � — ' I I I I 17216 51 st Ave NE, I I I I I I I Industrial Park,Building B i Arlington,WA 98223 I I II i ! I III Prepared For C I! Bond I Plumbing, LLC II I I I I I I I I I 19023 36th Ave W.Suite G 'I Lynnwood,WA 98036 I I III i I I i i IIIII I I IIII i � I I i I IIII � I i II i I i Ii IIII I! III THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND p FCO' FCCI FCC' FCO PLUMBING,LLC. FOR INFORMATION .i CONTACT: CURTIS BOND. No. DATE REHSION I II I I I III I I I ! I I I I I I 6"W®1%----_11 6"w®1%—� 6"w@1%��I I I I I ji"cW UP TO %"CW UP To Le 1 �HB_1 - - - - - - -� E PARTNER IN CHARGE 6"W@l% 6 W 6 W@1% /- O 1 / /- O PROJECT MANAGER I.E.=84'+ I.E.=84"+ - LE.=84'+ 1 I..=90" ➢➢ BELOW FINISHED FL BELOW FINISHED FL R BELOW FINISHED F R BELOW F� HED FL OR z DJ r r= PROJECT ENGINEER m m BQ PROJECT TEAM MEMBERS F CHECK BQ I I I I I I I O ENGINEERS SEAL rOP7AI�L F�'l� 6/15/2023 UNDERGROUND PLUMBING PLAN - WESTERN END SCALE: Jfs"=1'-0" LU TITLE o UNDERGROUND PLUMBING PLAN G PROJECT N0. 2023-051 DATE JUNE 15,2023 W /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE gEET NUMBER BURR MEASURES ;H P1 .00 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. P O 2"W UP TO FD(0 DFU) ---------- -------------------------- W UP(4 DFU) -w I 2-V UP(4 0FU)-1 2-V UP(4 DFU) lwv UP(0 )FUJ--, HV Engineering,Inc. 3-W(4 DI —3-W(4 DFU) ------- ----------I------ Consulting Engineers zrw P (6 DI 2"W Up--------------- Hall Creek OfficePark 3"W P C I E)6*W- -2 3"W r)- . -i I-W IWW UP(I DFU) 1W'W UP(I D rtJ)-- (2 6912 220th St.SW Suite 303 Mountlake Terrace,WA 98043 3-W(7 DIV— 1 2 W( ',DFU) 3-W(5 DFU) ------- Phone:(206)706-9669 ------------ -4- 1 k4-- 4-- hNongineeiring.biz -------- �3-111`POC TO(E)6-W ew Pod TO(E)6*W 3-W POC TO(E)6-W 1 V \-\-3- (4 EIF�) %' OF DFW, r I Project %--------Q TENANT IMPROVEMENT: SERVICE MASTERS 1WW UP 3"W UP (11 DFU) Location (3 DFU) 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 Prepared For - Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND ENLARGED PLUMBING PLAN PLUMBING,LLCON A DESIGN BUILD UNDERGROUND CONCEPT.THEY ARE TO BE USED ONLY OMEN'S AND WOMEN'S RESTROOMS WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION "�01 SCALE: Y4"=1'-0* CONTACT: CURTIS BOND. NO. DATE REMSION PARTNER IN CHARGE S13 PROJECT MANAGER DJ PROJECT ENGINEER 1310 PROJECT TEAM MEMBERS JM CHECK 1310 ENGINEERS SEAL OF WASy A. 6/15/2023 TITLE UJ UNDERGROUND V) ENLARGED PLANS PROJECT NO. 2023-051 DATE JUNE 15,2023 W PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INC. THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF TV ENGINEERING,INC.AND IS NOT TO BE 0"�1" P 0 1 USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC ACCORDINGLY. 3 4 5 6 7 9 0 O I......... KI I J l><L A 11: HV Engineering,Inc. Consulting En.n— Hall Creek Office Park 6912 220th St.SW,Suite 303 Mountlake Terrace,WA 98043 Phone:(206)706-9669 B hNenginecring.blz Project TENANT IMPROVEMENT: SERVICE MASTERS Location 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 Prepared For C ------ Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 it THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND it PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLYli WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. NO. DATE REMSION zPARTNER IN CHARGE Zl S13 z A A Z-� CT MANAGER Aik A&\IL DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS F CH im ,CK -77 7 BQ ENGINEERS SEAL 5 6/15/2023 LEVEL I PLUMBING PLAN WESTERN END SCALE: 1'-0" LJJ TITLE LEVEL 1 LJJ PLUMBING PLAN PROJECT NO. 2023-051 DATE JUNE 15,2023 W PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE gFET—NumBER BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF TV ENGINEERING,INC.AND IS NOT TO BE 0" P2.00 USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC ACCORDINGLY. I 1)J-CW(13.75 WSFU) f.5 ---------- 11,"CW(4 WSFU) CW(18.75 WSFU) ) -I.To SERVE(2) URINALS V(4 DFU) I)CCW(5.75 WSFU) WCW F -:4 :� --------------------- -------- To(E)41 HW(4.175 NI c CW(2,,87,' A 3FU) A HV Engineering,Inc. 1)FCW(22.525 WSFU) G, 6—2-V(4 DFU) Consulting Engineers L 4 DFU I --------- ------ Hall Creek Office Park 3",1 POC 10(E) 1"VTR L 6912 220th St.SVV,Suite 303 W(1.125 WSFU Mountlake Terrace,WA 98043 W71J) 1 A IY2 CO (19.875 WSFU) —------- ---- ------- Phone:(206)706-9669 L Vill 20.625 WSFU) 2-V(5 DFU) 2"V -ILL(2), 2 W ROUTED IN DFU)- ----- (6 DFU) DFU)L7 4" �-*-HW(2.625 111 2"V(7 I Pro ect 'b66 66 I)FCW(21.625 WSFU) 2-V(16 EIFIJ) 2 W:D /(:4) j L Ljj TENANT IMPROVEMENT: L5 \/WR\/-E—T\/'C—P\ J_ (3 DFU) X-HW(0.7 WI SERVICE MASTERS \-2-V(9 DFU) Location 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 Prepared For - Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND ENLARGED PLUMBING PLAN PLUMBING,LLCON A DESIGN BUILD 1ST FLOOR CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND OMEN'S AND WOMEN'S RESTROOMS PLUMBING,LLC. FOR INFORMATION SCALE: 1'-0" CONTACT: CURTIS BOND. NO. DATE REMSION PARTNER IN CHARGE S13 PROJECT MANAGER DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS im CHECK BQ ENGINEERS SEAL OF WASy A. 6/15/2023 TITLE Uj LEVEL1 V) ENLARGED PLANS PROJECT NO. 2023-051 DATE JUNE 15,2023 W PROJECT NETWORK PATH a— REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INC. THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF TV ENGINEERING,INC.AND IS NOT TO BE 0"—1" P2.01 USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC ACCORDINGLY. MAX 1)FCW PIPE )F BRANCH ADJUSTABLE STRAINER NON-SHRINK GROUT \_ _ _ — YF BALL ACCESS DOOR(AT RECESSED F— UNION TYP. FINISH LOCATION IN FINISHED SPACES) OFFSET HOT WATER MAIN TO HAND DEPRESS DRAIN 1/4" TO 1/2" FLOOR I I PPP P2-500 O WHERE NOT ALREADY SLOPED I PRIME RITE TRAP SINK/LAVATORY AS NEEDED. PRIMER VALVE / Y/ MANUFACTURER'S THERMOSTATIC DISTRIBUTION UNIT TEMPERING VALVE DHERE APPLICABLE f DRAIN AFFOR EVERY I WHERE APPLICABLE CLAMPING RING 20'OF PRIME LINE I I NOTE: ROUTE HOT WATER PIPING MAIN }fit"COPPER TO FLOOR OVER TO LAVATORY SUCH THAT NO MORE DRAIN,TRAP MAKE UP THAN 2'OF"DEAD"BRANCH PIPE EXISTS. WATER(TYP.)QTY.AS TYPICAL FOR ALL AND LAVATORIES. REQUIRED(MAX 2) HV Engineering,Inc. PROVIDE TRAP PROVIDE WATERPROOF TYPICAL LAVATORY PRIMER MEMBRANE AT ALL FLOOR Consulting Engineers DRAINS, FLOOR SINKS, AND L — — — — J Hall Creek Office Park TRENCH DRAINS. 6912 220th St.SW,suite 303 Mountlake Terrace,WA 98043 DRAIN PIPE n FLOOR DRAIN DETAIL n TRAP PRIMER DETAIL n TYPICAL LAVATORY PIPING DETAIL Phone:(206)706-9669 www.hvegineering.biz P3.00 SCALE: NTS P3.00 SCALE: NTS P3.00 SCALE: NTS Project TENANT IMPROVEMENT: SERVICE MASTERS Location 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 Prepared For Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 GATE VALVE(TYPICAL) UNION(TYPICAL) CIRCULATING PUMP CHECK VALVE(TYPICAL) BALANCE VALVE (TYPICAL) W(SIZED PER PLAN) THESE DRAWINGS WERE DEVELOPED W(SIZED PER PLAN) FOR EXCLUSIVE USE BY BOND INSTALL PER PDI PLUMBING,LLC ON A DESIGN BUILD STANDARDS AND Y4"HWC CP CONCEPT.THEY ARE TO BE USED ONLY MANUFACTURER'S HOT OR COLD WATER SUPPLY IF BRANCH IS GREATER THAN 20' (2 GPM) 1 y4 CW/HW/HWC WITHIN 15' WITH WRITTEN PERMISSION OF BOND INSTRUCTIONS LONG,PROVIDE ANOTHER WHA IN MIDDLE,EACH SIZED FOR HALF OF WATER HEATER TO PLUMBING,LLC. FOR INFORMATION THE FIXTURE UNITS ET BE COPPER(TYP.) CONTACT: CURTIS BOND. PDI e 1 SIZE PER PLANS SIZE IF HORIZONTAL BRANCH IS LESS No. DATE REVISION •A"" THAN T LONG,PROVIDE ONE EXPANSION- — fWHA AT END OF UNE TANK PDI SIZE SINGLE FIXTURE MULTIPLE FIXTURES STRAP WATER HEATER TANK TO WALL FOR I PC PROVIDE WATER HAMMER RELIEF VALVE,PRESSURE AND SEISMIC RESTRAINT.TWO PLACES. PPE FIXTURE FIXTURE UNIT TABULATION ARRESTERS TERS BY SIOUX CHIEF, TEMPERATURE.PIPE DRAIN FULL SZE UNIT LOAD FIXTURE COLD HOT PRECISION PLUMBING PRODUCTS, SIZE TO MOP SINK BELOW A X�" 1-3 WATER CLOSET g __ WATTS OR APPROVED EQUIVALENT WITH WH PISTON AND 0-RING CONSTRUCTION, SIZE PER PLANS B 1" 4-12 LAVATORY/HAND SINK 1 1 HAVING PDI#WH-201,ASSE#1010 1 AND ANSI#A712.26.1M CERTIFICATION. C 1" 13-25 KITCHEN SINKS 1.5 1.5 INSTALL IN HORIZONTAL OR VERTICAL D 1Y" 26-50 MOP BASIN 3 3 POSITION,BUT NEVER UPSIDE DOWN. DRAIN VALVE,TYP. INSTALL IN LINE WITH WATER FLOW PARTNER IN CHARGE E 1J¢" 51-BS URINAL 5 -- DIRECTION IF POSSIBLE. SIZE THE W.H.DRAIN TO UNITS AS SHOWN ON THE DRAWINGS APPROVED LOCATION R10 INSULATION UNDER Sp13 CT MANAGER AND/OR PER THE TABLES SHOWN FLOOR/PLATFORM TANK PER ABOVE. 4r, DJ DRAIN PAN PROJECT ENGINEER (2) WATER HAMMER ARRESTERS WATER HEATER DETAIL BQ PROJECT TEAM MEMBERS P3.00 SCALE: NTS P3.00 SCALE: NTS JM CHECK BQ ENGINEERS SEAL A. OF WASy 2 IGq.7p1,�'l� 6/15/2023 LL1 nnISOMETRIC V) RISER DIAGRAMS G PROJECT N0. 2023-051 DATE JUNE 15,2023 W /'� PROJECT NETWORK PATH a- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES INC. A.O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING P3.00 r HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. O 19"CW(5.75 WSFU) HV Engineering,Inc. Consulting Engineers I)FCW(13.75 WSFU) Hall Creek Office Park 6912 St.SW Suite 303 Mountlake Terrace,WA 98043 Phone:ongi 7efing. l �y'HWC � www.nNer,glneerl�g.oi, 1WCW(4 WSFU) 1A Project II TENANT IMPROVEMENT: OR 1A IVII SERVICE MASTERS 1h"CW(18.75 WSFU) L 3 1A P3.00 Location ` �1}¢"CW(19.875 WSFU) � 1)FCW(20.625 WSFU) 17216 51 st Ave NE, Industrial Park,Building B �e ` ,\ Hw(0.75 WSFU) Arlington,WA 98223 1A "HW(2.625 WSFU) Prepared For ' ^ e 1}�"CW(21.625 WSFU) / \ 1 Bond Plumbing, LLC 3 P3.00 IM 19023 36th Ave W.Suite G IWCW(22.625 WSFU e lh-V(4 DFU) Lynnwood,WA 98036 `-1)�'CW POC TO(E) 1}¢'CW `\ 1)¢7CW(24.875 WSFU • I WHW(4.875 WSFU `.i �� 2"V(4 DFU) THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND 1}�"CW(26.5 WSFU) `\ / I I �� /`2"V(5 DFU) PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION CONTACT: CURTIS BOND. N0. OATS RENSION "CW l DF I I � ' L Y4"HW 1A ' WH a 2V(4 DFU) Y ej J r l P3.00 ET 2 i 2"V(6 DFU) j i UR \ W(5 DFU) UR 3"W(4 DFU) --\2-W(9 DFU) \ \ 3"W POC TO(E)6"W RISER DIAGRAM - 1ST FLOOR P4.00 2"W(`DFU) PER IN CHARGE S13 D PROJECT MANAGERMEWS AND WOMEN'S RESTROOMS SCALE: NONE 2'V(7 DFU) DJ %2-V(16 DFU) PROJECT ENGINEER BQ 3'W POC TO(E)6'W PROJECT TEAM MEMBERS 3"W(7 DFU) CHECK \y� BQ ENGINEERS SEAL YIN(6 DFU) "W(4 DFU) 1)Tv(4 DFU i 3'W POC TO(E)6"W of WASy I I `2"V(20 DFU) i i 5" 2"V POC TO(E)3"v ; 6/15/2023 YIN POC TO(E)6"W J TITLE SOMETRIC 3"W(4 DFU) �e RISER DIAGRAMS G PROJECT N0. 2023-051 RISER DIAGRAM - 1ST FLOOR DATE JUNE 15,2023 OMEN'S AND WOMEN'S RESTROOMS w PROJECT NE WORK PATH P4.00 SCALE: NONE REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ; P4.00 H w .O O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC. IS NOT TO 6E U USED,IN WHO OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. /jtp/►�,ajL LUCERNE TM �'taivaita/ WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE LUCERNETM WALL-HUNG LAVATORY • Wall-hung sink • Vitreous china • Front overflow ' • D-shaped bowl • Self-draining deck area with contoured ' - back and side splash shields • Faucet ledge • Compliant with Texas accessibility standard (TAS) for children age group 13 and up Faucet holes on 203mm (8") centers (Illus.): ❑ 0356.028 For exposed bracket support Shown with 4801.862 Amarilis Heritage faucet with Triune Cross handles (not included) ❑ 0356.015 For wall hanger(included) or concealed arms support ❑ 0356.915 For wall hanger (included) or 0356.028 concealed arms support • Less overflow Faucet holes on 102mm (4") centers: ❑ 0355.027 For exposed bracket support ❑ 0355.012 For wall hanger(included) or concealed arms support ❑ 0355.912 For wall hanger (included) or concealed arms support • Less overflow Single center faucet hole (Illus.): ❑ 0356.041 For exposed bracket support Shown with 1340.000 metering faucet (not included) ❑ 0356.421 For wall hanger(included) or concealed arms support ❑ 0356.921 For wall hanger (included) or concealed arms support • Less overflow 0356.041 ❑ 0356.439 For wall hanger (included) or concealed arms support SEE FOLLOWING PAGES FOR ROUGHING-IN DIMENSIONS •Single faucet hole on right ❑ 0356.066 For exposed bracket support •Single faucet hole on right To Be Specified: ❑ Color: ❑White Nominal Dimensions: ❑ Faucet*: 521 x 464mm ❑ Faucet Finish: (20-1/2" x 18-1/4") ❑ Supplies: Bowl sizes: ❑ 1-1/4"Trap: 381mm (15") wide ❑ Nipple: 254mm (10") front to back ❑ Bracket Support(by others): 165mm (6-1/2") deep ❑ Concealed Arms Support(by others): Compliance Certifications - Meets or Exceeds the Following Specifications: • AS ME Al l2.19.2/CSA B45.1 for Vitreous See faucet section for additional models available China Fixtures MEETS THE AMERICANS WITH DISABILITIES ACT GUIDE- ® LINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. Top of front rim mounted 864mm(34")from finished floor. M37 C 2016 AS America Inc. spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 LUCERNE TM S� WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE 0356.028 8" CTRS FOR EXPOSED BRACKET SUPPORT 0355.027 4"CTRS FOR EXPOSED BRACKET SUPPORT 0356.015 8" CTRS FOR WALL HANGER 0355.012 4"CTRS FOR WALL HANGER OR OR CONCEALED ARMS CONCEALED ARMS 0356.915 LESS OVERFLOW 0355.912 LESS OVERFLOW t 86mm 86mm 102mm (3-3/8') 102mm (3-3/8") FINISHED (4") 0 FINISHED(4") FINISHED WALL 203mm WALL 203mm WALL 152mm 152mm 464mm 102mm 464mm 152 mm 203mm (18-1/4") (q) (18-114") 152mm I I I I emm 8mm (6)25mm (5/16") (6)25mm (1')DIA. (1")DIA. ACCESS ACCESS 13mm HOLES 13mm HOLES FOR (1/2") (1/2') CONC.ARMS 521mm FOR 521mm (20-1/2") CONC. (20-1/2") ARMS 425mm 425mm (16-3/4") (16-3/4") 267mm 267mm (10-1/2') 54mm(2-1/8")DIA. (10-1/2')� 114mm HOLES FOR 114mm (4-1/2") CONCEALED ARMS (4-1/2') 54mm(2-1/8")DIA. 102mm 44mm 25mm 102 m 4-3/4 HOLES FOR (1 3/4") (1-3/4') CONCEALED ARMS (4") (1') i^1 /l�I (4") 25mm �1 /� +- -+ +IV 1" -+- +I 79mm 1 �I 79mm /mil 7 (3-1/8") ______� ♦ *298mm (3-18") ♦ --+--J 206mm (11 i (8-1/8") 38mm 0 38mm 10mm(3/8') 10mm (18m. DIA.ANCHOR *286mm (1'1/2') E 3/8')) (11-1/4') DIA. HOLEES c? SCREW HOLES *352mm SCREW HOLES E S-9 HANGER 2le)m (13-7/8') S-9 HANGER 20 e Im *.- N 27mm X 14mm ♦ ♦ 27mm x 14mm ♦ ♦ + m (1-1/16"x 5/16")SLOTS /j /// SLOTS SUPPLIES) / SUPPLIESf� 1 Vy AS REQUIRED J// 787mm(31') AS REQUIRED E E 1-1/4"O.D.WASTE 864mm(34") 1-1/4'O.D.WASTE 1-1/4"O.D.WASTE 1-1/4"O.D.WASTE OUTLET FOR OUTLET FOR OUTLET FOR OUTLET FOR FINISHED FINISHED DRAIN PLUG POP-UP DRAIN f FLOOR 1® DRAIN PLUG POP-UP DRAIN f FLOOR 1 T7 18-1/4" FINISHED 18-1/4" FINISHED (464mm) WALL (464mm) r WALL 8"MIN. 8"MIN. 34" - (203mm) 34" (203mm) (864mm) (864mm) 27"MIN. 27"MIN. (686mm) (686mm) 6"MAX. _ 6"MAX. (152mm) (152mm) BARRIER FREE 9"MIN. ,BARRIER FREE 9„MIN. CLEARANCE (229mm) CLEARANCE (229mm) 11" 11" (279mm) (279mm)� NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Al12.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. FLAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM(34")ABOVE FINISHED FLOOR. M38 ©2016 AS America Inc. PART OF l I X I` spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 LUCERNE TM 54t7 ; / WALL-HUNG LAVATORY VITREOUS CHINA ® BARRIER FREE 0356.041 SINGLE CENTER HOLE FOR EXPOSED 0356.439 SINGLE CENTER HOLE ON RIGHT FOR WALL BRACKET SUPPORT HANGER OR CONCEALED ARMS 0356.421 SINGLE CENTER HOLE FOR WALL 0356.066 SINGLE CENTER HOLE ON RIGHT FOR HANGER OR CONCEALED ARMS EXPOSED BRACKET SUPPORT 0356.921 LESS OVERFLOW 44(1-3/4")DIA. 251m(1-3/8')DIA. 349mm 35mm(1-3/8')DIA. STD.OUTLET PUNCHING (13-3/4•) PUNCHING 102mm 86mm (4.) (3-3/8") 114mm 86mm (4-1/2') (3-3/8") FINISHED 203mm WALL (8�) FINISHED 203mm 15(6") WALL (6) 13mm x 51mm BRACKET (1/2"x T)SLOTS 464mm 44mm(1-3/4")DIA. 464mm STD.OUTLET (18-1/4') 152mm (6„) 102mm 25mm(1')DIA. i (4)i HOLES Bmm 57mm Bmm (6)25mm(1")DIA. ACCESS HOLES } 1 FOR CONC.ARMS 13mm (1/2•) 425mm (16-3/4') 13mm 521 mm (112") (20-1/2") 521 mm (20-1/2') 425mm 425mm (16-3/4') (16-3/4') 7267mm 267mm 10-1/2') (10-1/2')~ 114mm 14mm (4-1/2") 4-1/2') 54mm(2-1/8")DIA. 54mm(2-1/8")DIA. HOLES FOR 102mm 44mm 25mm I HOLES FOR 102mm 44mm CONCEALED ARMS (4") (1-3/4") CONCEALED ARMS 25mm - - + + + + 0") I+ +`Fig + +I 79mm �- II i�l } (3.1/8") --1-_1 / / (391/8") 206mm 206mm 382 10mm(3/8") I 38mm J 10mm(3/8") (1-1/2") DIA.ANCHOR 787mm(31') (1-1/2") DIA.ANCHOR 787mm(31') SCREW HOLES 864mm(34') SCREW HOLES ®864mm(34') S-9 HANGER S-9 HANGER 27mm X 14mm FINISHED ® FINISHED (1-1/16'x 5/16")SLOTS FLOOR 27mm X 14mm f FLOOR (1-1/16"x 5/16')SLOTS T7 18-1/4" FINISHED 18-1/4" FINISHED (464mm) WALL (464mm) WALL 8" MIN. 8"MIN. 34" (203 m m) 34" (203 m m) (864mm) (864mm) 27"MIN. 27"MIN. (686mm) (686mm) 6" MAX. 6"MAX. (152mm) (152mm) BARRIER FREE 9, MIN. BARRIER FREE'*.,'.- MIN. CLEARANCE (229mm) CLEARANCE (229mm) 11" 11" (279mm) (279mm) NOTES: *DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND"P"TRAP ARE SUGGESTED. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY OTHERS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard At12.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. ❑LAVATORY DESIGNED TO MEET ADA HANDICAPPED GUIDELINES WITH MOUNTING HEIGHT (� SET AT 864MM(34")ABOVE FINISHED FLOOR. M39 ©2016 AS America Inc. PART OF L I X I L spec_0355-0356 Lucerne WallHung Lays Rev.A 8/16 4;;Iof?pems Madera'" FloWise° 16-1/2" Height Sea�7 Elongated Flushometer Toilet VITREOUS CHINA with EVERCLEAN° ® BARRIER FREE Madera'" FloWise° 16-1/2" Height Elongated with EverClean® • • Floor mount flushometer valve toilet • Vitreous china • High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf) • Meets definition of HET (High Efficiency Toilet) I when used with a high efficiency flush valve (1.1 gpf, 1.28 gpf or 1.6/ 1.1 gpf dual flush) • Permanent EverClean°surface inhibits the growth R of stain and odor-causing bacteria, mold, and mildew on the surface • Fully glazed 2-1/8" trapway • Elongated bowl • 10" or 12" roughing-in '""ft • 16-1/2" rim height for accessible application • Condensation channel prevents water from dripping on the floor • Powerful direct-fed siphon jet action • 10" x 12" water surface area • 1-1/2" inlet spud SEE REVERSE FOR ROUGHING-IN DIMENSIONS • 2 bolt caps included System MaP* Score: • Tested to support static weight load of 2,500 lbs. • 1,000 grams of miso @ 1.1 gpf, 1.28 gpf or 1.6 gpf (1,134kg) when used with an American Standard flush valve *Maximum Performance(MaP)testing performed by IAPMO ❑ 3461.001 Elongated bowl only, top spud R&T Lab. MaP Report conducted by Veritec Consulting, Inc. ❑ 3462.001 Elongated bowl only, top spud and Koeller and Company. with slotted rim for bedpan holding OPERATING PRESSURE: ❑ 3465.001 Elongated bowl only, top spud 25 psi (flowing) - 80 psi (static) with 4 bolts ❑ 3466.001 Elongated bowl only, top spud with FLOW REQUIREMENT: slotted rim for bedpan holding with 4 bolts 25 gpm (94.6 L/min.) ❑ 3463.001 Elongated bowl only, back spud ❑ 3464.001 Elongated bowl only, back spud with slotted rim for bedpan holding Component Parts: To Be Specified: ❑ 047007-0070A Inlet Spud (furnished with bowl) ❑ Color: ❑ White ❑ 034783-0200A Bolt caps with retainers ❑ Seat: (furnished with bowl) ❑American Standard#5901.100 Heavy duty open front less cover Nominal Dimensions: ❑American Standard#5901.100SS Heavy (2 8-1/4" x 14" x 16-1/2")8 x 356 x 419mm duty open front less cover with EverClean° ❑ Flushometer Valve: Fixture only, less seat and flush valve Compliance Certifications - Meets or Exceeds the Following Specifications: CE0 r •ASME A112.19.2/CSA B45.1 for Vitreous l� China Fixtures ENVIROMENTAL when'I'd with EVERCLEAN WATER PRODUCT 1.1or1.28gpf EFFICIENT r� MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES DECLARATION toilet flush valves 101 AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE v BUILDING FACILITIES-CHECK LOCAL CODES. ©M9 2021 AS America Inc. spec_3461.001 Madera FW 16.5 Height EL Flushometer Rev 6 5/21 Madera' FloWiseO 16-1/2" Height S� Elongated Flushometer Toilet VITREOUS CHINA with EVERCLEAN® ® BARRIER FREE 3461.001/3462.001 1"N.P.T.OR 1"C.W.T.SUPPLY FINISHED WALL TO FLUSH VALVE- 121mm 7 A (4-3/411) 711mm 470mm (28) B (181/2")� 356mm (14") 1 1/2" Dimension 10"(254mm)Rough 12"(305mm)Rough C C/L OF SEAT PO?NE `SPUD A 718mm(28 1/4") 768mm(30 1/4") /�140mm(5-1/2") 1 B 102mm(4") 152mm(6") i C 25mm(1") 76mm(3") 19mm D 254mm(10") 305mm(12") 6- /2") i 1 E 76mm(3") 380mm(5") I�362mm 3465.001/3466.001 150m(m4 1/4) FLOORED 254mm 4-BOLT ANCHOR DETAIL " 13mm (5 7/8) (10") (Bottom View of Bowl) (1/2") C/L OF OUTLET D---' 512mm 3463.001/3464.001 (20-1/4") FINISHED WALL 159mm A i (6-1/4") E �~470mm 356mm i (18-1/2") (14") C/L OF SEAT POST HOLES 12mm (1/2") ► 140mm(5-1/2")CENTERS — --- - HOLES '150mm'150mm (5-7/8")(5-7/8") 438mm 419mm (16-1/2") i 362mm)� FINISHED 150mm ( 14-1/4" FLOOR 254mm 113mm (5-7/8") (10") (1/2") D C/L OF OUTLET NOTES: PRODUCT 3461 AND 3463 SHOWN,3462 AND 3464 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF 254MM(10")AND A MAXIMUM DIMENSION OF 305MM(12")FROM FINISHED WALL TO C/L OF OUTLET. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.FLUSHOMETER VALVE REQUIREMENTS FOR 12"(305MM)ROUGH-IN:SWEAT EXTENSION NIPPLE IS REQUIRED.REFER TO VALVE MANUFACTURER AND LOCAL CODES. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Al12.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. M10 0 2021 AS America Inc. PART OF L I X I L spec_3461.001 Madera FW 16.5 Height EL Flushometer Rev 6 5/21 4;Pof?k� Washbrook° FloWise° s� Universal Urinal VITREOUS CHINA ® BARRIER FREE Washbrook® FloWise® Universal Urinal • Vitreous china • Ultra High Efficiency, Low Consumption. Operates in the range of 0.125gpf to 1.Ogpf(0.5 Lpf to 3.8 Lpf) • Flushing rim • Elongated 14" rim from finished wall • Washout flush action • Extended sides for privacy • 3/4" inlet spud • Outlet connection threaded 2" inside (NPTF) • 2 wall hangers • Fixture only • Strainer included • Meets ASME flush requirements at 0.125 to 1.0 gpf ❑ 6590.001 Universal Top spud ❑ 6515.001 Universal Back spud f Nominal Dimensions: 360 x 480 x 664mm (14-1/8" x 18-7/8" x 26-1/8") SEE REVERSE FOR ROUGHING-IN DIMENSIONS Recommended working pressure—between To Be Specified: 20 psi at valve when flushing and 80 psi static ❑ Color: ❑ White ❑ Flush Valve: Compliance Certifications - 1.0 gpf Flush Valve: Sensor-Operate®: ❑American Standard Selectronic #6063.101.002 Meets or Exceeds the Following Specifications: DC Power(Top Spud) • ASME A112.19.2-2008/CSA B45.1-08 for Vitreous ❑American Standard Selectronic®#6062.101.002 China Fixtures AC Power(Back Spud) 1.0 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.101.002 0.5 gpf Flush Valve: Sensor-Operated: ❑American Standard Selectronic°#6063.051.002 DC Power(Top Spud) ❑American Standard Selectronic°#6062.051.002 AC Power(Back Spud) 0.5 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.051.002 0.125 gpf Flush Valve: Sensor-Operated: ❑American Standard Selectronic®#6063.013.002 DC Power(Top Spud) ❑American Standard Selectronic®#6062.013.002 AC Power(Back Spud) 0.125 gpf Flush Valve: Manual-Operated: ❑American Standard#6045.013.002 �5e0� A��� MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES ��' —C'` —" AD4 AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND v FACILITIES-CHECK LOCAL CODES. When used with When used with ADA •When installed so top of rim is 432mm(17")MAXIMUM from finished floor. 0.125 gpf 0.125 or 0.5 gpf COMPLIANT urinal flush vale urinal flush vale M155 ©2018 AS America Inc. spec_6590.001-6515.001 WashbrookUrinal Rev 11/18 Washbrook° FloWiseO S� Universal Urinal VITREOUS CHINA ® BARRIER FREE 6590.001 TOP SPUD 6515.001 BACK SPUD 121 mm�.� (4-3/4") 3/4"S.P.S. FINISHED yf OR 3/4"C.W.T. WALL T SUPPLYTO FINISHED FLUSH VALVE 292mm 3/4" j 64mm I WALL (11-1/2") SPUD K2 HANGERS (2-1/2'. 51mm K2 HANGERS 51mm (2��) I � (2") (8mm x 25mm 1 Smm x 25mm �� �+�� SLOT x 1 ) �� 42 j�*� (5/16"x 1") — 7 SLOT 3/4" t 343mm t 343mm SPUD 445mm (13-1/2") (13-1/2") (17-1/2") 480m 35m 171/2') 9-1/4') (180M.. (9-1/4") ( 480mm 464mm (18 7/8) 464mm 664mm (18-1/4") 664mm (18-1/4") (26-1/8) 360mm (26 1/8) 360mm REF. (14-1/8") REF. (14-1/8") 13mm 13mm (1/2") (1/2") 83mm 83mm —T, ■432mm® 0432mm 161 C/L OF (17")MAX 102mm C/L OF (17")MAX 2"N.P.T. 102mm OUTLET 610mm(24") 2"N.P.T. (4") OUTLET 610mm(24")FEMALE OUTLET (4") OPTIONAL FEMALE OUTLET OPTIONAL CONNECTION FINISHED FLOOR CONNECTION FINISHED FLOOR 13mm 13mm (1/2") ASKET (1/2") GASKET i�r 1 1 rn r I I 1 r- `u` i�102mm� 13mm �\2" 02mm, 13mm Ili N.P.T. 2"N.P.T. FINISHED WALL INSIDETHREADS FINISHED WALL INSIDETHREADS DETAIL OF OUTLET CONNECTION DETAIL OF OUTLET CONNECTION ■ , MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES-CHECK LOCAL CODES. •When installed so top of rim is 432mm(17")MAXIMUM from finished floor. NOTES: FLUSH VALVE NOT INCLUDED AND MUST BE ORDERED SEPARATELY. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.These measurements are subject to change or cancellation.No responsibility is assumed for use of superseded or voided pages. M156 ©2018 AS America Inc. PART OF L I X I L spec_6590.001-6515.001 WashbrookUrinal Rev 11/18 46. W.160th St. Dearborn Oleveland.Ohio44135 CAST GRID WHEELCHAIR Ph:(800)321-9532 Brass Fax:(dea)ornbra35 PATENT OUTLET PLUG vnHv.d e a rbo rn b ras s.com SUBMITTAL SPECIFICATION Engineering Specification: Dearborn Brass Semi-Cast Wheelchair Grid Patent Overflow Job Reference Plug with 1-%"—17 gauge tailpiece. DESCRIPTION • Chrome Finished • Includes: Cast Grid, P.O. Plug with nuts and washers, 90' Elbow and 17 gauge tailpiece • Designed for installation in most commercial _ applications r, I I�2-1/5"� DIP_ 2-314' 5-114' 7- 112" —i 1-114" 1— Product Description Carton Carton Weight(Ibs) No. Quantity 760W-1 Semi-Cast Grid Wheelchair Patent Overflow Plug 10 14 with 1-%"—17 gauge Tailpiece Data is subject to manufacturing tolerances. Visit www.dearbornbrass.com for updates 03/2009 L=wL I�, 0 o� .R Ll 1111 1 THIS PRODUCT,AS CONSTRUCTED IS SUBJECT TO INTERPRETATION OF A.D.A. REQUIREMENTS. THE UNOBSTRUCTED KNEE SPACE REQUIRED TO SATISFY A.D.A. f t STANDARDS MAY NOT BE DESIRABLE. j ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP PRODUCT SPECIFICATIONS Elkay Enhanced ezH2O®Bottle Filling Station, &Versatile Bi-Level ADA Cooler, Filtered Refrigerated Light Gray. Chilling Capacity of 8.0 GPH (gallons per hour)of 501 F drinking water, based on 801 F inlet water and 901 F ambient, per ASHRAE 18 testing. Features shall include Antimicrobial,Automatic Filter Status Reset, Energy Savings, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain, Visual Filter Monitor. Furnished with Flexi-Guard®Safety Bubbler. Electronic \, Bottle Filler Sensor with Electronic Front and Side Bubbler Pushbar activation. Product shall be Wall Mount(On Wall),for Indoor - applications, serving 2 station(s). Unit shall be certified to UL 399 and CAN/CSA C22.2 No. 120. Unit shall be lead-free design which is certified to NSF/ANSI 61 &372(lead free)and meets Federal and State low-lead requirements. Special Features: Antimicrobial,Automatic Filter Status Reset, Energy Savings, Filtered, Green Ticker TM, Hands Free, Laminar Flow, Real Drain,Visual Filter Monitor Finish: Light Gray Granite AMERICAN PRIDE. A LIFETIME TRADITION. Like your family,the Elkay family has values and traditions that Power: 115V/60Hz endure.For almost a century,Elkay has been a family-owned and USA Bubbler Style: Flexi-Guard®Safety Bubbler operated company,providing thousands of jobs that support our ®. Activation by: Electronic Bottle Filler Sensor with families and communities. Electronic Front and Side Bubbler Included with Product: Bottle Filler, Pushbar Water Cooler, Mounting Type: Wall Mount(On Wall) Filter Chilling Capacity*: 8.0 GPH Ships in one box. Full Load Amps 5 PRODUCT COMPLIANCE Rated Watts: 370 ADA& ICC A117.1 Dimensions(L x W x H): 36-3/4"x 19"x 39-1/2" Approx.Shipping Weight: 104 lbs. ASME Al 12.19.3/CSA B45.4 Installation Location: Indoor Buy American Act No. of Stations Served: 2 CAN/CSA C22.2 No. 120 *Based on 80' F inlet water&90' F ambient air temp for 50' F chilled GreenSpec° drinking water. NSF/ANSI 42, 53, 61, &372 (lead free) Special Note: One-Box Packaging. UL 399 • Visual Filter Monitor: LED Filter Status Indicator for when filter GreenSpec s change is necessary. 6 r • Ab- • Filter is certified to NSF 42 and 53 for lead, particulate, U$ `� � L I ST E o chlorine,taste and odor reduction. 3,000 gal. capacity. c us www Gre SPe< ' • Energy-Savings Feature-allowing for the refrigeration to be Complies with ADA&ICC Al 17.1 accessibility requirements when installed according to the requirements outlined in these standards.Installation may powered off when not In use. require additional components and/or construction features to be fully • Green Ticker: Informs user of number of 20 oz. plastic water compliant.Consult the local Authority Having Jurisdiction if necessary. bottles saved from waste. Installation Instructions(PDF) • Laminar flow provides clean fill with minimal splash. • Silver Ion Antimicrobial protection on key plastic 5 Year Limited Warranty on the refrigeration system of the unit. components to inhibit the growth of mold and mildew. Electrical components and water system are warranted for 12 months • Real Drain System eliminates standing water. from date of installation. Warranty pertains to drinking water applications only. Non-drinking water applications are not PART: QTY: covered under warranty. PROJECT: Warranty(PDF) CONTACT: DATE: NOTES: APPROVAL: In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Pagel LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP COOLING SYSTEM • Compressor: Hermetically-sealed, reciprocating type, OPTIONAL ACCESSORIES single phase. Sealed-in lifetime lubrication. 51300C- Elkay WaterSentry Plus Replacement Filter(Bottle Fillers) • Condenser: Fan cooled, copper tube with aluminum WSF6000R-2PK-WaterSentry Fresh 6000 CTO Replacement Filter fins. Fan motor is permanently lubricated. (2pack) • Cooling Unit: Combination tube-tank type. Continuous MLP200-Accessory- In Wall Carrier(Bi-Level)for bi-level EZ, LZ, copper tubing with is fully insulated with EPS foam that EMABF, LMABF,VRC, LVRC models meets UL requirements for self-extinguishing material. LKAPREZL- Elkay Cane Apron for EZ Gray • Refrigerant Control: Refrigerant R-134a is controlled by accurately calibrated capillary tube. • Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 2 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP IMPORTANT! OPERATION OF QUICK CONNECT FITTINGS INSTALLER PLEASE NOTE : This water cooler has been designed and built to provide water to the user which Simply push in Tube is secured I Push in collet to has not been altered by materials in the cooler waterways.The grounding of electrical tube to attach in position release tube equipment such as telephone,computer,etc_to water lines is a common procedure. A B C The grounding maybe in the building but may also occur away from the bulling.This � « grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below. Pushing tube in before NOTICE pulling it out helps to This water cooler must be connected to the water supply using a dielectric coupling.The F.—I release tube cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. These products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. WaterSentry®Plus Filter System Standard Hli-Low Installation Instructions 1s° (458mm) (467mm) 7° 7" (178mm) (178mm) 7/16"X 3l4" ((11 mm X 19mm 0 ROUND HOLE(6) 0 9/32" r — 3m (7mm ACTIVATION (483mm) 6-318" 6-70mL�S(12) 6-3/8" 6-3/8" SENSOR 901/ (162mm) (162mm) (162mm) (162mm)' HANGER (381 mm) BRACKET 483mm) — 38-1/2" O s'Imm __ �� (979mm) E = -=—i- --2. 2-7/8" --, (51mm) _ 38-3/8" FILTER r e i i m/ 1--^ --- 73mm (975mm — 1 (�2Jm) i -1—_-' E s�mm) bHEIGHT 0 ii -r "i ---- I 36-13/16" 51-/16" i i A (1310mm i i PREFERRED 28-13/16' (936mm) 34-/16" F i i i i i i I LOCATION (731mm) HEIGH (205mRIM ") I3ii T 205mm (872mm) i L--�---- --i -- --i 32-/8" FILTER -- —_� i (835mm) L 2,N/2" ORIFICE C (622mm) T HEIGHT i _ _ _ 21-718" 31-5/16" 2-15116' —_ (556mm) (686mm) (583mm) RIM 17-7116" HEIGHT 27" 1-/8" 19-116" (51mm) F (443mm) (686m ) (4ADA8mm) (494mm) 3-718' 13-15/16" 19" 3 5-314" (98mm) (354mm) (483mm) REQUIREMENT (76mm) 146mm 1 ( 7" 7" (318mm8mm) (178mm) (178mm) LEGEND: REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51 mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply 3)Wire Recessed Box Duplex Outlet. E=Insure proper ven Ration by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7/16"(11 mm)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI). It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 3 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP_spec.pdf Elkay Enhanced ezH2O Bottle Filling Station LE & Versatile Bi-Level ADA Cooler SPECIFICATIONS Filtered Refrigerated Light Gray Model LZSTL8WSLP IMPORTANT! OPERATION OF QUICK CONNECT FITTINGS INSTALLER PLEASE NOTE : Simply push in Tube is secured Push in collet to This water cooler has been designed and built to provide water to the user which P y P has not been altered by materials In the cooler waterways.The grounding of electrical tube to attach in position release tube equipment such as telephone,computer,etc.to water lines is a common procedure. The grounding may be in the building but may also occur away from the building.This x ~ grounding can cause electrical feedback into a water cooler creating an electrolysis A B C which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown Pushing tube in before below. pulling It out helps to NOTICE release tube This water cooler must be connected to the water supply using a dielectric coupling.The cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. Bottle filler unit on bracket attached to wall by 6 holes(as shown).Water and electrical will connect through pre-punched hole in basin. These products are designed to operate on 20 psi to 105 psi supply line pressure.Simultaneous operation of both bubblers on a bi-level unit may not be possible depending on water supply pressure.If simultaneous operation is desired,please ensure a minimum of 65 psi supply. Watersentry Plus Filter System 18" Optional Reverse(Hi-Low) Installation Method (458mm) 18-3/8" 7/16"X 3/4" 7„ 7" (467mm) (11mm X 19mm) (178mm) F(i 78mm) 19 OBROUND HOLE(6) (483mm) 51-518" ACTIVATION (1311mm) 6-3/8" 6-3/8" SENSOR 3-1/2" i (162mm) (162mm) (90mm) 15" 6-3/8" 6-3/8" HANGER (381mm (162mm) (162mm) (07m/m)2) BRACKE HOLES(12) I i �• (38-318" 38-9/16" 2716' 111 E ORIFIC� (979mm) (73rnm) HEIGHT PREFERRED E '-- LOCATION 36-13/16' __ (936mm) 28-13116" r Q i (51mm) 34-5116" RIM (732mm) B --i i 22mm) I 871mm) HEIGHT FILTER r- 32-7/8" - I I- i i _ I (835mm) (205mm) -- 1 11,7 i - --- - - ORIFICE ' II --L i i I I _ HEIGHT FILTER 21-718" i i �• i 31-5/16" (556mm) F I 2" (796mm) I 19" (5 3/4'� F 2-1 /16' RIM C (483mm) T (146/mm) (583mm) HEIGHT 3-7/8" 27" (178mm) (178mm) 24-1/2" (686mm) 1-7/8" 443m16" (98mm) 119`-7/116"(622mm) ADA (48mm) REQUIREMENT 3" 12-1/2" (76mm) 13-15/16" (318mm) (354mm) FINISHED FLOOR LEGEND: REDUCE HEIGHT BY3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER A=Recommended Water Supply location.Shut-off Valve(not furnished)to accept 3/8"O.D.unplated copper tube.Up to 3"(76mm)maximum out from wall. B=Recommended Waste Outlet location.To accommodate 1-1/2"nominal drain.Drain stub 2"(51 mm)out from wall. C=1-1/2"Trap(not furnished). D=Electrical Supply(3)Wire Recessed Box Duplex Outlet. E=Insure proper ventilation by maintaining 6"(152mm)minimum clearance from cabinet louvers to wall. F=7116"(11 mm)Bolt Holes for fastening to wall. Note:New Installations Must Use Ground Fault Circuit Interrupter(GFCI).It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps. In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets. This specification describes an Elkay product with design,quality,and functional benefits to the user. When making a comparison of other producers'offerings,be certain these features are not overlooked. Elkay REV 05082021 1333 Butterfield Road, Suite 200 ©2021 Page 4 LZSTL8WSLP Downers Grove, IL 60515 LZSTL8WSLP—spec.pdf PROFESSIONAL CALIBER When it comes to eliminating system pressure, FLEX 2 PRO PH is your safe bet. o Worrying about eliminating system pressure is a thing of the past! FLEX 2 PRO PH potable water expansion tanks are designed to maintain safe pressure in domestic water systems that utilize a back flow preventer or check valve. Equipped with a stainless steel system connection to prevent corrosion, the � - FLEX 2 PRO PH is in a FLEXCON whole different league. A Swan Group Company Potali4 N',,leL�Tank Stainless steel water connections ..N .,.m �,..N. hu. 0 PHI2.1 p.11n.a NO rGl IN esm to reduce corrosion. Mt.I-- E..r,I o..: — 16 gauge solid steel tank,finished with highest quality urethane paint. Steel clench ring regulates movement and prevents diaphragm from rubbing against tank wall. PROBLEM SOLUTION FIXTURE .ACNFLOW pH VALVE CLOSE. PREVENTED OR Tank CHECK VALVE PH series thermal expansion tanks effectively eliminate built up system pressure. 100%pressure tested and backed with a 1 year limited warranty. o Adding a backflow Installed on the cold preventer, check water inlet, PH series valve or water meter thermal expansion with a check valve tanks provides a reser- creates a closed voir for the water to loop system. When expand. The water water heats up, it safely enters the expands with no place tank and is released to go except through back into the system the relief valve. on demand. ©2017 Flexcon Industries REV:9-17 PH SERIES TYPICAL INSTALLATION Potable Water Cold Hot 4;12> Expansion Tanks =Backkfiow Relief MATERIALS OF CONSTRUCTION Valve ■ Tank: 16 gauge cold rolled steel WH ■ Finish:Appliance quality paint for indoor or outdoor installation SERIES ■ Water chamber: 100% butyl rubber, lined with polypropylene ■ Connection:Stainless steel ■ Testing: High pressure, seam weld, helium, final precharge check ■ Air valve: Brass valve with o-ring seal ■ Warranty: 1 year limited DIMENSIONS & CAPACITIES ModelF2. l Tank A B C Total c us •••w••= ume Height Diameter Connection Weight liters in cm in cm Ibs kilos PH 5 8 11.6 30.00 8.0 20.00 3/4"MNPT 5.00 2.3 PH 12 18 14.5 37.00 11.00 28.00 3/4"MNPT 10.00 4.6 PH 25 32 1 18.9 48.10 1 12.50 31.80 3/4"MNPT 15.40 7.0 Maximum working pressure 150 psig. Maximum working temperature, internal&external 200,F.Tank pre-charge 40 psig. NOTE: Ph Series tanks are certified to NSF Standard 61 Domestic Hot, but are suitable for temperatures up to 200,F. C B QUICK SIZING CHART Water Heater Maximum Water Temperature Size/Volume 1301 F 1400 F 1600 F 1800 F 30 GALLONS PH 5 PH 5 PH 5 PH 5 40 GALLONS PH 5 PH 5 PH 5 PH 5 A 50 GALLONS PH 5 PH 5 PH 5 PH 12 60 GALLONS PH 5 PH 5 PH 5 PH 12 80 GALLONS PH 5 PH 12 PH 12 PH 12 100 GALLONS PH 12 PH 12 PH 12 PH 25 120 GALLONS PH 12 PH 12 PH 12 PH 25 150 GALLONS PH 12 PH 12 PH 25 PH 25 175 GALLONS PH 12 PH 25 PH 25 PH 25 *Consult Factory LPc_ Sizing based on water heater recovery from 40F, water supply pressure of 60 PSIG, and relief valve set at 150 PSIG. Adjust tank precharge to equal incoming water pressure. FLEXC _ ■ 0 A Swan Group Company O www.fIexconind . coin O 8 0 0- 5 2 7-0 0 3 0 O 300 Pond Street, Randolph , MA 02368 PRODUCT SPECIFICATION DRAWING QUICKSTANDTm 21-1/2" X 21-1/2" (Water Heater & Equipment Support) #40-S-22-A (assembled) and #40-S-22-U (unassembled) Item#1 ono`. e o ❑21 1/2" Item#4-1W'0' / 0o ae Item#2 Item#5 • • e e o Item#3 ® 16" 2 1/4"typ The QUICKSTANDT"' #40-S-22- (A or U) stands safely elevates water heaters and other equipment above the floor (650 Ibs rating). ALL DIMENSIONS IN INCHES Product Information: • Material: Item #1: Top, 16 gage CRS, galvanized Item #2: Leg, 16 gage CRS, galvanized, 4 places Item #3: Safety Clip, 14 gage CRS, galvanized, 2 places Item #4: Screw, Php, HexWasherHd, #1/4-14 x 1/2"L (serrated), 16 places Item #5: Lag Bolt, #1/4 X 2-1/2"L, self-drilling, 2 places SAFETY CLIP(2) (note: items #3 and #5 included with product) ITEM#3 • Engineered and lab tested to meet Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) requirements, including elevation of water heater's ignition source 18" above the floor LAG BOLT(2) ITEM#5 • Holds up to 650 pounds capacity (up to 52 U.S. gallon tanks) • QUICKSTANDTM weight 15 pounds without packaging Product Submittal Job Name: • Available in asembled and unassembled configurations Date: Part Number: Qty: THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION. Architect/Owner: HOLUT - V. ® Contractor: Notes: CONVERTING MAKESHIFT METHODS INTO ENGINEERED SOLUTIONSsm 800-321-0316 OR 760-744-6944 / FAX:760-744-0507 / WWW.HOLDRITE.COM Spec_40-S-22-16ga_RevE MOEN@ S p e ci f i c a t i o n s COMMERCIAL DESCRIPTION • Brass construction with chrome plated finish • 1/2"IPS connections • 8"centers • Vandal resistant torx head screws OPERATION • Wrist blade style handles with hot and cold color indicators FLOW • Water usage is limited to these maximum flow rates as indicated by the corresponding product markings '1.5 gpm max(5.7L/min)at 60 psi CARTRIDGE • Brass shell,ceramic disc cartridge • 1/4 turn operation STANDARDS Two-Handle Kitchen Faucet • Third party certified to ASME Al 12.18.1/CSA B125.1 and all applicable specifications referenced therein • Certified to NSF 61/9&372 Model' 8289 • Complies with California Proposition 65 and with the Federal Safe Drinking Water Act • ADA ® for lever handles WARRANTY • Warranted for 5 years against material or manufacturing defects NOTE:Designed to be installed through 2 or 3 holes- 1"min.dia.and on 8"on center 8-1/2" 12" (216mm) (305mm) 16" (407mm) 2-1/4"� 8" (57mm) (204mm) 4-1/4" (108mm) 2-1/8" (54mm) r 10-1/4" (260mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.4/16 www.moen.com MOEN@ S p e ci f i c a t i o n s COMMERCIAL DESCRIPTION • Solid brass construction • Chrome,Brushed Chrome or Brushed Nickel finish • 1/2"IPS connections • Solid brass waterways OPERATION • Lever handle • Temperature controlled through 1 10'arc of handle FLOW Standard aerator is limited to 2.2 gpm max.(8.3 L/min) Single Handle Lavatory Faucet CARTRIDGE • Ceramic disc cartridge*(with temperature limit stop) • Nonmetallic/nonferrous and ceramic material WATERSENSE STANDARDS MODEL FLOW(gpm) DRAIN FINISH CERTIFIED • Third party certified to WaterSense°(only applies to 1.5 gpm), 8413 2.2 without Chrome ASME All 12.18.1/CSA B125.1,and all applicable requirements 8413F15 1.5 without Chrome x referenced therein including NSF 61/9 84131`05 0.5 without Chrome • Contains no more than 0.25%weighted average lead content 84131`03 0.35 without Chrome • Complies with California Proposition 65 and with the Federal Safe 8414 2.2 Metal Chrome Drinking Water Act 8414BC 2.2 Metal Brushed Chrome • ADA ® for lever handles 8414BN 2.2 Metal Brushed Nickel WARRANTY �atier5e��� • Warranted for 5 years against material or manufacturing defects r' o s EPA G� : See table above I NOTE: This faucet is designed to be installed thru 3 holes, 1"min.dia. HOT COLD 55' 55' 7" (128mm) 6" (153mm) a d 111 1 6-5/8" 5-5/8" O y__ (168mm) (143mm) 2-1/2" 5" (64mm) (127mm) I I LI-1/8"MAX. (29mm) 2" 2" (51mm) (51mm) 2-7/16" ^(62mm) CRITICAL DIMENSIONS (DO NOT SCALE) MOEN SPECIFIER SERVICES 1-800-321-8809 Ext.2158 Rev.9/12 www.moen.com ELM MUSTEE 27F and 27W UTILATWIN° Preferred by the"Pros" Laundry/Utility Tubs — Premier SEE PAGE 2 FOR A LIST OF Design features: • High strength, one piece molded construction ■ Produced with Mustee's proprietary structural thermoplastic resins and innovative cellular molding process creating extreme strength&durability • Includes Twin-Drain Waste connector which joins drain assemblies to assure rapid and uniform waste water discharge...includes washers,slip nuts and stoppers. ■ Divider wall between tubs is recessed one inch, permitting water to 4 overflow from one tub to other, prevents water spilling onto floor. • Large,self-draining back shelf with retainer curb that prohibits water run- off except into tub. ■ 19 Gallon capacity per tub,extra deep 13"tubs with smooth surfaces ■ Connects to standard 11/2" P or S trap ■ Accommodates single or dual-handle faucets.4" or 8"centers ■ Floor model includes heavy gauge steel legs with adjustable levelers ■ Wall model includes wall mounting bracket, side supports and mounting hardware for securing tub to concrete or stud wall ■ Mold and mildew-resistant components ■ Easy to assemble and install ■ Color-fast white finish Code Accepted: UTILATUBO and UTILATWINO Laundry/Utility Tubs meet or exceed performance requirements as listed: c o ■ International Association of Plumbing and Mechanical Officials(IAPMO)O Listed W • Warnock HerseyO(Canada) Listed—CSA test standards: Laundry Tray-#645.0 and#1345.5; Drain -#13125 Intertek ■ American National Standards Institute(ANSI)—Specification Z 124-2011 ANSI Specifications Colors & Models: Model Mounting H x W x D UPC White 27F Floor 34" x 40" x 24" 6 71031 00057 6 White 27W Wall 34" x 40" x 24" 6 71031 00058 3 MOUNTING 8gA0 General: Furnish and install as shown on plans, UTILATWIN@ Twin Laundry/Utility 194 Tub model (27F,27W),as manufactured by E.L.Mustee&Sons, Inc.Tub shall 143/8' a�" be one-piece molded construction using structural thermoplastics with matched metal molds under extreme heat and pressure.Tub to include integrally molded 34" drains,twin drain waste coupling, recessed divider wall between tubs and twin 34" q Aqqqox. A,q�x PA E G drain assembly for connection to standard 1-112"P or S-trap,stoppers and wall AOJ/NGT ENT ROOq 2a mounting hardware or heavy gauge steel legs with built-in levelers. 19 gallon 40" capacity per tub,each tub 13"deep.Shall meet ANSI Z 124-2011.Color:White. wr w mil Weight:27F 40 lbs.;27W 40 lbs. ELM ,Y,USTEE E-mail:info@ usteelcom. • Web:www.mtustee com - Proudly mh Street - Brook Park,ade in the USA hone:216.267.3100 • Fax:216.267.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. ElM ® MUSTEE 27F and 27W UTILATWIN° Preferred by the"Pros" Laundry/Utility Tub Accessories Faucet �i Faucet Block For use with overhead water supply AA'.I�IR !1'A 11 Allr,t h,r11 HandiFlo- Fitting NAtiL•r.,i NA't. Faucet Model No. UPC 93.600 6 71031 00232 7 g Chrome finish,4"center set brass faucet. 7"swing spout with aerator, level handles, replaceable seats and stems.Areator or hose end. Faucet Block Model No. UPC 20.600 6 71031 00031 6 Used when water supply lines are above the tub. Mounts to tub shelf when using a clamp-on faucet. HandiFlo' Fitting Model No. UPC 94.700 6 71031 00287 7 Dispenses water from washing machine discharge hose into laundry tub. Eliminates draping washer machine hose over back/side wall of laundry tub and conceals discharge hose. Mounts to back or side wall of laundry tub, includes mounting hardware. E�M MUSTEE E-mail:info@ usteelcom. 5 Web:www.mustee.com - Proudly made n the USA ne:216.267.3100 • Fax:216.267.9997 Notice:Our continuous commitment to product improvement may result in changes to product specifications without notice. Patents pending.Made and Printed in U.S.A. Residential Electric ' Water Professional Prestige Water Heaters The new degree of comfort® Professional Prestige° electric water heaters offer a diagnostic system with leak protection ila and a 12-year warranty Efficiency Features • .93 UEF • High performance and lower • Isolated tank design reduces operating cost conductive heat loss •Compliant with many electric utility • Dual 5500 watt stainless steel heating incentive programs elements • Premium grade anode rod provides Performance long-lasting tank protection • FHR: 56-63 gallons based on gallon ' Electric junction box located above capacit Y heating elements for easy installation • Recovery: 25 GPH at a 90°F rise** 'Over-temperature protector cuts off power in excess temperature Super Sentinel Diagnostic situations System Plus... •Simple easy to read diagnostics • EverKleen"self cleaning device fights •Controls multiple operating modes harmful sediment build-up with a • Digital thermostat setting high-velocity spiraling water stream— helps operating efficiency by saving • Built-in water sensor alert with audible energy, money and improving tank life alarm and service notifications . Enhanced-flow brass drain valve •Temperature and pressure relief valve 0 EcoNet` included • Low lead compliant • EcoNet®WiFi-connectedt Warranty Professional Prestige technology and free • 12-Year limited tank and parts 40 and 50-Gallon Capacities mobile app gives users warranty* 240 Volt AC/Sin le Phase control over waterg systems, allowing for `See Residential Warranty Certificate for Electric complete information customizable temperature,vacation t WiFi broadband internet connection required settings,energy savings and system monitoring at home or away. Units meet or exceed ANSI requirements and have UL Visit Rheem.com/EcoNetConnect been tested according to D.O.E.procedures.Units meet or exceed the energy efficiency requirements •Water sensor detects water outside of NAECA,ASHRAE standard 90,ICC Code and all LEED Point=7 of the unit and sends an alert via state energy efficiency performance criteria. the free EcoNet®mobile app to the homeowner • EcoNet®WiFi Kit included See specifications chart on back. _D, INTEGRATED HOME COMFORT PRINTED IN U.S.A.12/17 WP FORM NO.PROPE RH Rev.4 Residential Electric ' Water Professional Prestige II Water Heaters The new degree of comfortm Professional Prestige° Electric Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO. T UEF UNIFORM Y NOMINAL RATED FIRST HOUR RECOVERY TANK HEIGHT TO APPROX ENERGY P GALLON GALLON MODEL RATING IN G.P.H. T.HEIGHT WATER CONN. DIAMETER SHIP W FACTOR E CAPACITY CAPACITY NUMBER G.P.H. 90'F RISE A B C (LBS.) (UEF) Tall 40 36 PROPE40 T2 RH95 EC2 56 25 60-3/4 63-5/8 18-1/4 105 0.93 Tall 50 45 PROPE50 T2 RH95 EC2 63 25 58-5/8 61-5/8 20-1/4 121 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy(DOE)requirements. Super Sentinel not available on single element models,available on dual element models only.Super Sentinel not 8" available in excess of 5 kW on 208 V models. •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 5500 watt upper and lower heating elements. **Recovery=wattage/2.42 x temp.rise°F. Example: 550OW =25 GPH HOT 2.42 x 90' WATER �° CONNECTION COLD **Recovery calculations used are based on 5500 watt WATER elements used in non-simultaneous operation. RELIEF VALVE CONNECTION CONNECTION � ANODE ROD C� DIAMETER Q B WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rheem.com INTEGRATED HOME COMFORT PRINTED IN U.S.A.12/17 WP FORM NO.PROPE PH Rev.4 ADJUSTABLE FLOOR DRAIN FINISH FIXTURE 11832 SERIES FinishLine" ITEM#SUBMITTED JOB NAME SPECIFICATION Sioux Chief 832 Series FinishLine finish fixture for adjustable floor drain shall be LOCATION used where necessary in drainage systems. Finish Fixture shall allow adjustment ENGINEER of 1.25" after the concrete pour when used with FinishLine rough-in fixtures. Strainer shall be heel-proof and meet all applicable load requirements for CONTRACTOR intended use. Designed in accordance with ASME A112.6.3 Po# TAG MATERIALS Top Housing:ABS with threaded brass inserts Strainer:ABS — 1 LOAD RATING = 500 Ibs(Light Duty, pedestrian traffic) STRAINER FREE AREA 8.74" two DIMENSIONS A: Top diameter 61/2" 832-4HPR B: Overall height 27/8" C: Outlet diameter 4" A i B 1 �c- 832-4HPR SkxjxChM Sioux Chief Manufacturing Company I P: 1.800.821.3944 F: 1.800.758.5950 I www.siouxchief.com COMMERCP - - --- - - ON-GRADE ADJUSTABLE FLOOR DRAIN Item#Submitted 832 series Finish LineT" Job Name SPECIFICATION Location Sioux Chief 832 series Finish Line adjustable on-grade floor drain shall be Engineer used where necessary in drainage systems. Floor drain shall allow adjustment Contractor of 1.25"before the concrete pour,and 1.25"after the concrete pour. Floor drain shall have a Sch.40 hub connection,which conforms to ASTM D2665 Po# TAG (PVC)or D2661(ABS).Connection to drainage system shall be made with a solvent weld joint to ABS/PVC pipe.Strainer of floor drain shall fasten into female threaded brass inserts.Strainer shall be heel-proof and meet _ applicable load requirements for intended use.Trap primer port shall be threaded 1/2"FIP for knockout connection. MATERIALS ring/strainer: nickel-bronze,304 stainless steel head adapter:ABS with threaded brass inserts coring sleeve:ABS coring plug:high-impact polymer 832-4PNQ base adapter:ABS or PVC STRAINER LOAD RATING nickel-bronze: 1,000 lbs.(light duty, pedestrian traffic) stainless steel:2,000 lbs.(light duty,pedestrian traffic) STRAINER FREE-AREA round: 11.75 in2 square: 16.4 in2 DIMENSIONS A: connection size 2"*,3",or 4"Sch.40 hub B: ring/strainer diameter round 61/2 B i square 7" I E C: adapter height 2"hub 45/8" 3"hub 43/8" 4"hub 45/8" ° D: pre-pour adjustable height c 2"hub 51/2"-63/4" F 3"hub 51/4"-61/2" 4"hub 51/2"-63/4" A E: post-pour adjustable height Models 832-2ANR,832-2PNR, round W-11/4" uPc 832-2ANQ,832-2PNQ, square 5/16"-11/4' 832-36ANR,832-36PNR, F: trap primer port 1/2"FIP thread for knockout connection 832-36 list and 832-36PNQ are UPC listed *2"hub connection is factory installed 2"x 3"bushing in 3"hub model. Create Item Number 832-ABC D e.g.832-36PNR=Finish Line drain with 3"Sch.40 hub connection with round nickel-bronze ring and strainer A CONNECTION SIZE C RING &STRAINER ACCESSORIES ❑ 2 2"Sch.40 hub ❑ NR round nickel-bronze ❑ 832-UM stainless steel debris bucket ❑ 36 3"Sch.40 hub ❑ NQ square nickel-bronze ❑ 832-S4 shim kit ❑ 4 4"Sch.40 hub ❑ SR round stainless steel ❑ 863-FA aluminum condensate funnel ❑ SQ square stainless steel ❑ 863-FN nickel-bronze condensate funnel B CONNECTION TYPE ❑ 863-FNO oval nickel-bronze condensate ❑ A ABS base adapter D OPTIONS(FACTORY INSTALLED) funnel ❑ P PVC base adapter ❑ V vandal-resistant strainer screws ❑ 832-EX4 ductile iron extension nipple ❑ E 13/8"extended strainer rim 1 ❑ 832-W locating bristle kit ❑ H hinged strainer ❑ B complies with Buy American Act1 1 Available only on round nickel-bronze ring&strainer. SbuxChW Sioux Chief Manufacturing Company•tel:1-800-821-3944 • www.siouxchief.com •fax:1-800-758-5950 1-10 Drainage 9 ROYAL@ MANUAL FLUSHOMETER SL❑AN. ROYAL 186-1.0 CODE NUMBER 3012636 DESCRIPTION 1—row, fi 1.0 gpf, Polished Chrome Finish, Fixture Connection Top Spud,Single L",y Flush, Royal® Exposed Manual Urinal Flushometer. DETAILS • Flush Volume: 1.0 gpf(3.8 Lpf) • Finish: Polished Chrome(CP) • Valve: Diaphragm r • Valve Body Material: Semi-red Brass • Fixture Type: Urinal • Fixture Connection:Top Spud • Rough-In Dimension: 11 1/2" (292mm) COMPLIANCES & CERTIFICATIONS • Spud Coupling:3/4" (19mm) • Supply Pipe: 1/4" (19mm) FEATURES (ADA Compliant, cUPC Certified, BAA Compliant) • PERMEX@ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass RECOMMENDED SPECIFICATION • Sweat Solder Adapter with Cover Tube&Cast Wall Flange with Set Valve Body, Cover,Tailpiece and Control Stop shall be in Screw conformance with ASTM Alloy Classification for Semi-Red • Non-Hold-Open Handle, Fixed Metering Bypass and No External Brass.Valve shall be in compliance with the applicable Volume Adjustment to Ensure Water Conservation sections of ASSE 1037 and ANSI/ASME 112.19.2. • Diaphragm, Handle Packing and Vacuum Breaker to be molded VALVE OPERATING PRESSURE (FLOWING) from PERMEX® Rubber Compound for Chloramine Resistance 15-80 PSI (103-552 kPa). Specific fixtures may require greater • ADA Compliant Metal Oscillating Non-Hold-Open Handle minimum flowing pressure-consult manufacturer 3/4" I.P.S. Screwdriver Bak-Chek@ Angle Stop w/Free Spinning Vandal requirements. Resistant Stop Cap DOWNLOADS VIDEOS • Royal Exposed Installation Instructions • Control Stop Repair and Maintenance Guide PVD Special Finishes • Flush Connections Flanges Repair and Maintenance Guide • Tail Piece Repair and Maintenance Guide • Royal Manual Diaphragm Flushometer Repair and Maintenance Guide • Flushometer Pressure gauges • Additional Downloads NOTES All information contained within this document subject to change without notice. Looking for other variations of the ROYAL 186 product?View the general spec sheet with all options. Find a compatible urinal for this flushometer. Find a compatible water closet for this flushometer. Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3012636 • Downloaded 11/17/20 • Revised 07/28/20 •View Latest Version Page 1 of 2 ROYAL@ MANUAL FLUSHOMETER SLOAN@ ROYAL 186-1.0 ROUGH-IN �- 21/4"MIN. (57mm) I.P.S. SUPPLY o =Dr1*0 SUPPLY 43/4" (DN 20mm) 111/2" (121 mm) (292mm) CENTERLINE OF FIXTURE CENTERLINE OF WASTE FIN. F_ FIN. FLOOR WALL Sloan 10500 Seymour Ave, Franklin Park, IL 60131 Phone:800.982.5839 • Fax:800.447.8329 •sloan.com Code 3012636 • Downloaded 11/17/20 • Revised 07/28/20 •View Latest Version Page 2 of 2 L13 RegalO XL Flushometers ® Ill-XL ► Code Number 3080053 `L ► Description Exposed Water Closet Flushometer,for floor mounted or wall hung - top spud bowls. I ► Flush Cycle 1.6 gpf/6.OLpf ► Specifications Quiet,Exposed,Diaphragm Type,Chrome Plated Closet Flushometer with the following features: • ADA Compliant Metal Oscillating Non-Hold-Open Handle • 1"I.P.S.Screwdriver Bak-ChekO Angle Stop • Control Stop Plug • Sweat Solder Adapter with Cover Tube • Cast Wall Flange with Set Screw • Vacuum Breaker Flush Connection • Non-Hold-Open Handle and No External Volume Adjustment to Ensure Water Conservation �-21/4"MIN. (57 mm) • Low Consumption flush accuracy controlled by Para-FIOTM O 1"I.P.S. Technology SUPPLY • High Copper,Low Zinc Brass Castings for Dezincification o �43/4"— (DN 25 mm) Resistance (121 mm) Valve Body,Cover,Tailpiece and Control Stop shall be in 11 1/2" CENTERLINE conformance with ASTM Alloy Classification for Red Brass.Valve 292 mm) OF FIXTURE shall be in compliance to the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2. ► Accessories (Sold Separately) ❑ See Accessories Section of the Sloan catalog for available accessories CENTERLINE OF WASTE 0- Fixtures FIN. Consult factory for matching Sloan brand fixture options. FLOOR FIN. WALL ► Compliance&Certifications ® USA This space for Architect/Engineer Approval SLOAN 10500 SEYMOUR AVE.•FRANKLIN PARK,•IL.60131 Ph: 1-800-9-VALVE-9 or 1-847-671-4300•Fax: 1-800-447-8329 or 1-847-671-4380•http://www.sloan.com 2017-24-04 Page 1 of 1 T&S BRASS AND BRONZE WORKS, INC. Model No. 2 Saddleback Cove/ P.O. Box 1088 13-0230 Travelers Rest, SC 29690 UL . REG.#A2601 Item No. BO#9001 Travelers Rest SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity ADA Compliard Customer/Wholesaler Contractor Architect/Engineer 1811 2 3/8" [457mm] [60mm] Eterna Cartridges & 065X Lever Handles w/ 18" Swing Nozzle w/ Color Coded Indexes B-PT Stream Regulator Outlet 1- Mounting 91/2„ Surface [241 mm] J 6 3/4" 0211 [172mm] [51�mm] w/ 1/2 NPT Female Inlet 8" c/c [203mm] Adjustable from 7 3/4" to 8 1/4" [197mm to 210mm] Note: Rough-In Requirement (2) O 1" [25mm] Mounting Holes Product Specifications: Drawn Checked Approved Double Pantry Faucet w/ Eterna Cartridges, 18" Swivel Nozzle MIL JRM JHB w/ B-PT Stream Regulator Outlet, Lever Handles & 1/2" NPT Date: Female Inlets scale: 1:8 02/ 17/ 11 Sheet: l of 2 rip Ilp T&S BRASS AND BRONZE WORKS, INC. Model No. 2 Saddleback Cove/ P.O. Box 1088 &0230 Travelers Rest, SC 29690 U` . PM.#A2601 Item No. so#9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com ITEM SALES NO. DESCRIPTION NO. 1 065X 18" Swing Nozzle Assembly w/ B-PT Stream Regulator 2 B-PT Stream Regulator 3 001048-45 Nozzle Tip Washer 4 000922-45 Lever Handle Screw 5 001661-45 Red Index-HW 6 001638-45 Lever Handle 7 005960-40 Spindle Asm, Eterna "Hot" 8 009538-45 Swivel Washer 9 011429-45 Swivel Sleeves (2) 10 001074-45 O-Ring 11 001660-45 Blue Index-CW 12 005959-40 Spindle Asm. Eterna "Cold" 13 001019-45 Coupling Nut Washer 14 OOAA 1/2" NPT Female Inlet Assembly 3 5 8 2 6 9 10 1 7 11 12 ® -� 13 14 Product Specifications: Drawn Checked Approved Double Pantry Faucet w/ Eterna Cartridges, 18" Swivel Nozzle DHL JRM JH$ w/ B-PT Stream Regulator Outlet, Lever Handles & 1/2" NPT Female Inlets Scale: Date: NTS 02/ 17/ 11 Sheet: 2 of 2 Swivel Sink and Pantry Faucets TAG: B-0230-LN Double Pantry Faucet Architect/Engineering Specifications: 8"wall mount mixing faucet with polished chrome plated brass body,swivel outlet(less nozzle),compression cartridges with spring checks,lever handles and 1/2"NPT female inlets.Certified to ASME All 12.18.1/CSA B125.1,NSF 61-Section 9 and NSF 372. Meets ADA ANSI/ICC A117.1 requirements. Job Name Model Specified Quantity Variations Specified Date 12 5/8" [321 mm] 3 11/16" I [94mm] 8" 2 3/8" [203mm] [61 mm] Features&Benefits: Product Compliance: p • 8"wall mount mixing faucet with polished chrome plated . ASME A112.18.1 /CSA B125.1 S� brass body • NSF 61 -Section 9 C us • Swivel outlet accepts T&S swing nozzles • NSF 372(Low Lead Content) • Lock washer provided for rigid application pow • ANSI A117.1 (ADA) COMPLIANT • Quarter-turn Eterna compression cartridges w/spring checks to prevent cross flow of water Warranty: One Year(Limited) • Lever handle w/color coded indexes • 1/2"NPT female eccentric inlets w/Q 2"flanges El • Adjustable centers from 7 3/4"to 8 1/4" Performance Data: ADA Compliant • Material: Polished chrome plated brass body and chrome plated metal handles Pressure: 20- 125 psi • Temperature:40°F- 140°F T&S Swing Nozzles • Flow Rate: 28.63 GPM @ 60 psi ❑ 059X 6"Swing Nozzle (Outlet Device Wor Final Configuration May Reduce Flow Rate) ❑ 060X 8"Swing Nozzle Optional Outlets (Series 1 /VR Series 6) ❑ 061X 1 "Swing Nozzle El 062X 122"Swing Nozzle Non-Aerated VR Non-Aerated ❑ 063X 14"Swing Nozzle GPM Aerated (Laminar) VR Aerated (VR Laminar) ❑ 064X 16"Swing Nozzle 0.35 N/A ❑ B-0199-01-N035 N/A ❑ B-0199-06-N035 ❑ 065X 18"Swing Nozzle ❑ 066X 12" Double Joint Swing Nozzle 0.5 N/A ❑ B-0199-01-N05 N/A ❑ B-0199-06-N05 ❑ 067X 15" Double Joint Swing Nozzle 1.0 ❑ B-0199-01-F10 N/A ❑ B-0199-06-F10 N/A ❑ 068X 18" Double Joint Swing Nozzle 1.2 ❑ B-0199-01-F12 ❑ B-0199-01-LF12 ❑ B-0199-06-F12 ❑ B-0199-06-LF12 ❑ 069X 24" Double Joint Swing Nozzle 1.5 ❑ B-0199-01-WS ❑ B-0199-29 ❑ B-0199-06-WS ❑ B-0199-29VR 2.2 ❑ B-0199-01 ❑ B-0199-21 ❑ B-0199-06 ❑ B-0199-21-VRF T&S Swivel Goosenecks(D x K) ❑ 131X 2 13/16"x 2 9/16"Swivel Gooseneck Optional Handles Optional Cartridges With Checks ❑ 132X 2 5/8"x 5 7/16"Swivel Gooseneck ❑ 4"Wrist Action ❑ Quarter-Turn Cerama w/Check Valve ❑ 133X 5 11/16"x 6 1/4"Swivel Gooseneck ❑ Lever(Standard) ❑ Quarter-Turn Eterna w/Spring Check(Standard) ❑ 135X 8 3/4"x 5 5/8"Swivel Gooseneck ❑ 4-Arm T&S BRASS AND BRONZE WORKS, INC. •2 Saddleback Cove•Travelers Rest, SC 29690 i l Ph 800-476-4103• Fax 864-834-3518 Date: 01/22/18 i •Simi Valley, CA• Ph 800-423-0150•www.tsbrass.com T&S BRASS AND BRONZE WORKS, INC. Model No. 1W 2 Saddleback Cove/ P.O. Box 1088 061X Travelers Rest, SC 29690 Item No. Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 •www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler Contractor Architect/Engineer f 6 3/8" [163mm] 7B-PT Stream Regulator 3 5/16" Outlet [83mm] I 1 1/8" Swivel Nut Fits 10" [28mm] All Standard T&S [254mm] Swivel Outlets Product Specifications: Product Compliance: 10" Swing Nozzle w/ Stream Regulator Outlet ASME Al12.18.1 /CSA B125.1 NSF 61 -Section 9 NSF 372(Low Lead Content) Drawn: AMG Checked: JRM A roved: JHB I Date: 11/01/17 1 Scale: 1:2 Sheet: 1 of 1 Faucets and Fittings TAG: B-0230-K Parts Kit Architect/Engineering Specifications: Elbow kit. Two short elbows, nipples, lock nuts and washers that provide 1/2" NPT male inlet and outlet when assembled. Certified to ASME Al12.18.1/CSA B125.1, NSF 61-Section 9 and NSF 372. Job Name Model Specified Quantity Variations Specified Date 2 3/16" [56mm] 1 3/8" [36mm] 0 1 5/8" Minimum [41mm] 1 3/4" [44mm] Features&Benefits: Product Compliance: • Elbow kit ASME Al12.18.1 /CSA B125.1 c� u s • Two short elbows with 1/2" NPT male inlet and 1/2" • NSF 61 -Section 9 NPT female outlet • NSF 372(Low Lead Content) - - • Two 1/2" NPT supply nipples with lock nuts and washers !OW- L • Material: Brass Warranty: One Year(Limited) Performance Data: • N/A T&S BRASS AND BRONZE WORKS, INC. •2 Saddleback Cove•Travelers Rest, SC 29690 i M l Ph 800-476-4103• Fax 864-834-3518 Date: 09/30/16 1W .V'1. =p,' •Simi Valley, CA• Ph 800-423-0150•www.tsbrass.com GENERAL PLUMBING NOTES SYMBOL DESCRIPTION PLUMBING LEGEND PLUMBING LEGEND '` } 1. THE FOLLOWING NOTES APPLY TO ALL PLUMBING DRAWINGS ADDITIONAL PLUMBING 13. REFER TO.ELECTRICAL DRAWN S FOR ADDITIONAL ELECTRICAL•CHARACTERISTICS 27. PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM SYMBOL DESCRIPTION NOTES MAY BE INDICATED ON EACH PLUMBING DRAWING,SEE SPECIFICATIONS FOR OF PLUMBING.EQUIPMENT(VOLT GES,ETC.). PIPE SECTIONS. ' ADDITIONAL REQUIREMENTS. PIPING GENERAL 14...ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY 28. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW PIPING OFFSETS } 2 INSTALLATION SHALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS CONTRACTOR DURING SUBMITT L PROCESS ANY ELECTRICAL CHARACTERISTICS WHICH MAY BE REQUIRED. rIES (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE THAT DEVIATE FROM THOSE U TED SHALL BE IDENTIFIED BY THE CONTRACTOR, ROW ARROW CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SUBMITTED TO THE ENGINEER F R APPROVAL AND COORDINATED WITH DIVISION 26 29.. PATCH ALL FLOOR,WALL,CEILING AND ROOF OPENINGS CRI ATED/CAUSED BY THE NORTH NORTH ARROW SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL ELECTRICAL PRIOR TO INSTALL TION OF EQUIPMENT AS REQUIRED TO PROPERLY DEMOLITION OF EXISTING PIPES, FIXTURES,ETC. IN ACCOR ANCE WITH DIVISION 1 H CAP OR CLEANOUT TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH SERVE EQUIPMENT. OF THE SPECIFICATIONS. CONFUCT PRIOR TO PROCEEDING WITH INSTALLATION. O PIPE UP OR TEE UP AND DOWN 15. SECURE WATER HEATERS AND STORAGE TANKS.AND PLUMBING EQUIPMENT TO 30. ALL WATER PIPING IN UNHEATED SPACES EXCEPT CIRCULMED HOT WATER SHALL SECTION IDENTIFICATION 3. INSTALL ALL WASTE LINE CLEANOUTS IN ACCORDANCE WITH CHAPTER SEVEN OF STRUCTURE AS REQUIRED BY WE. REFER TO THE STRUCTURAL DRAWINGS FOR BE HEAT TRACED AND INSULATED. C PIPE DOWN A ' .THE UNIFORM PLUMBING CODE. ADDITIONAL SPECIAL REQUIREM TS RELATED TO THE PLUMBING INSTALLATION. A.3'WASTE PIPE-3"CLEANOUT WITH 2.5"PLUG 31.- WHERE PIPE SIZES ARE NOT SHOWN ON DRAWINGS, SIZE PI ING PER THE UNIFORM Q PIPE TEE UP B. C WASTE PIPE-4"CL.EANOUT WITH 3.5"PLUG 16.. PROVIDE PLUMBING ANCHORA AND EXPANSION EVERY 100' PIPE LENGTH PER PLUMBING CODE. C.6"WASTE PIPE-4"CLEANOUT WITH 3.5"PLUG CODE. .. PIPE TEE DOWN SHEET IDENTIFICATION32. PRIOR TO SUBMITTING ALL PLUMBING FIXTURES THE CONTRACTOR SHALL VERIFY 4. WASTE,VENT AND SUPPLY PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SHALL 17. ACCESS PANELS ARE REQUIRE AT ALL CONCEALED VALVES AND EQUIPMENT. COMPATIBILITY OF THE SPECIFIED FIXTURE WITH THE SIZES OF FINISH CABINETRY �- 45'DEGREE ELBOW O SHEET NOTES BE AS SHOWN ON PLUMBING FIXTURE SCHEDULES.BELOW GRADE SANITARY WASTE COORDINATE LOCATION AND SIZ WITH ARCHITECT. AS IDENTIFIED IN GENERAL CONTRACTOR'S SHOP DRAWING ANY DISCREPANCIES HV Engineering,Inc. PIPING SIZES SHALL BE AS SHOWN ON PLANS AND FIXTURE SCHEDULES AND BETWEEN THE SIZE OF THE FIXTURES SPECIFIED AND THE F141SH CABINETRY SIZES L W DEGREE ELBOW - SHALL NOT BE LESS AN 2"DIAMETER. 18. STUB OUT TO SITE SERVICE 5' OUTSIDE.BUILDING FOUNDATION, PIPE SIZE, SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINE IN WRITING BEFORE O1 .RISER CALLWT(RISER-1) Hall On n9 ega Pa, FIXTURE UNITS,AREA DRAINED,INVERT ELEVATION,SIZES,AND SQUARE FDTAGES SUBMITTAL 4 WAY TEE - Mall creek St.ffl SW,Suite 303 Park 5. ALL SANITARY SEWER PIPING BELOW SLAB SHALL BE INSTALLED AT A MINIMUM of AS INDICATED. NOTIFY ENGINE OF ANY DISCREPANCIES PRIOR TO COMMENCING (WC-1) Mtoun6912 aake re-,WA 98043 WORK: 33. PLUMBING VENTS SHALL TERMINATE A MINIMUM 10' FROM OUTSIDE AIR INTAKES, PLUMBING FIXTURE SAG 1/4" PER FT SLOPE UNLESS APPROVAL IS PROVIDED BY THE "ADMINISTRATIVE PER CODE. T �- TEE AUTHORITY.IN WRITIN FOR A SHALLOWER SLOPE. IN NO CASES SHALL SEWER Phone:1206)706-9669 PIPING BE INSTALLED AT LESS THAN 1 8" PER FT SLOPE. IN NO CASES WILL 19. INSULATE PIPING PER WSEC A PER DIVISION 22 SPECIFICATIONS(WHICHEVER IS Ql REVISION CALLOUT(REV-1) -h-9lneeeng.elz / GREATER). : 34. LABEL ALL PIPING SYSTEMS PER THE 1MC AND UPC. �- PIPE BREAK _ PIPING SMALLER THAN 4" BE INSTALLED SHALL SLOPES SHALLOWER THAN 1/4" PER .REVISION BUBBLE 11 .... u • FOOT.PIPING INSTALLED AT 1/8"/FT SHALL BE RESIZED PER CHAPTER 7 OF THE 20. GENERALLY DUCTWORK PLANNEDi0 BE TIGHT TO STRUCTURE WITH PIPING BELOW 35. SUPPORT AND BRACE PIPING SYSTEMS IN ACCORDANCE 1H UPC SECTION 314 `v UNIFORM PLUMBING CODE AND SUPPORTING CALCULATION SUBMITTED TO ENGINEER DUCTWORK AND BETWEEN UGHT FIXTURES ADJUST AS NECESSARY. AND AS REQUIRED IN THE SPECIFICATIONS. PIPING SPECIALTIES FOR REVIEW. 21. PIPING INSTALLED ADJACENT T ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM 36. ALL MATERIALS IN CONTACT WITH PIPING SYSTEMS SHALL�BE COMPATIBLE FOR � X X DETAIL CALLOUT(X/PX.XX) PPOJOO( 6. PROVIDE STOPS PRIOR TO ALL PLUMBING EQUIPMENT. THIS SHALL ALSO INCLUDE ACCESS OF 6" IF RUNNING PA iALUEL AND ABOVE CABLE TRAYS, ALLOW 18" TO USE WITH AND FOR CONTACT WITH THE PIPING MATERI CONTRACTORS AND TENANT IMPROVEMENT: PROVIDING INTEGRAL STOPS ON ALL SHOWER AND TUB/SHOWER VALVES(WHETHER THE SIDE OF CABLE TRAYS. TRADES SHALL VERIFY COMPATIBIUTY OF THEIR PRDU(TS WITH THE PIPING PRESSURE GAGE SPECIFIED OR NOT). PROVIDE WASTE TRAPS AT ALL DIRECT CONNECTED SYSTEMS.THIS INCLUDES,BUT IS NOT LIMITED TO, FIRE ST PING SEALANTS,FIRE �- SERVICE MASTERS COLUMN GRID SYMBOLS EQUIPMENT IN ACCORDANCE PATH CODE AND THE SPECIFICATIONS 22 COORDINATE LOCATIONS OF PLI MBING EQUIPMENT TO PROVIDE CLEARANCES OVER STOPPING COLLARS, VIBRATION ISOLATION ELEMENTS, �--++ ERMAL INSULATION, UGHTING FIXTURES FOR REM AL AND SERVICE ACCESS DUE TO EQUIPMENT EXPANSION JOINTS AND ANY MATERIAL IN CONTACT WITH PIPES. THERMOMETER A --------- 7. PROVIDE TRAP PRIM I S AT ALL FLOOR DRAINS UNLESS NOTED OTHERWISE. MAINTENANCE. - --® SIGHT GLASS /_\ Location - PROVIDE UNIOIV ON STREAM AND DOWNSTREAM SIDE OF ALL TRAP PRIMERS 37. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRAP PRIMER BRANCH TAKEOFF SHALL BE FROM TOP OF MAIN DISTRIBUTION PIPE 23. REFER TO PIPING DIAGRAMS At D DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (q ) AND BE LISTED BY VENTURI FLOW METER 1 7216 51 S[Ave NE, FLOOR PLANS AND SECTIONS I DICATE EQUIPMENT LOCATIONS AND GENERAL PIPE NSF INTERNATIONAL --ICI- 8. INSULATE P-TRAPS EXPOSED IN UNHEATEDSPACES. - ROUTING ONLY. O GENERAL MECHANICAL NOTES 38. PIPE BURIAL METHODS FOR BELOW GRADE PIPING SH COMPLY WITH MFR NUMBER IDENTIFICATION Industrial Park,Building B (a 9. SEE ARCHITECTURAL )RAVINGS FOR PLUMBING FIXTURE ROUGH-IN DIMENSIONS 24, PROVIDE FABRICATED STEE MEMBER SUPPORTS AS REQUIRED BY INSTALLATION INSTRUCTIONS,AS1M D 2321 AND ASTM F166 FLOW METER.FAILURE TO FOLLOW � FLAG MECHANICAL NOTES Arlington,WA 98223 AND OTHER DETAILS* ALSO SEE ARCHITECTURAL DRAWINGS FOR FINISH MANUFACTURER'S INSTALLATION INSTRUCTIONS,AS INDICATED ON DRAWINGS,OR IN THESE REQUIREMENTS CAN LEAD TO PIPE FAILURE. NUMBER IDENTIFICATION REQUIREMENTS OF A PLUMBING FIXTURES INCLUDING REQUIREMENTS FOR FLUSH SPECIFICATIONS FOR INSTA VI OF EQUIPMENT. REQUIRED STRUCTURAL lj��` PC1; LEVER LOCATION AT A COMPLIANT TOILETS AND VALVE LOCATIONS OF ADA .MEMBERS, BOLTS, AND WE SHALL BE IN ACCORDANCE WITH AMERICAN 39. ROOF MOUNTED PIPING SHALL BE INSTALLED ON FREE FLOWING, PREFABRICATED l MANUAL AIR VENT(MAV) EXISTING WORK OR BACKGROUND F``I * SHOWERS.REPORT ALL DISCREPANCIES TO ENGINEER PRIOR TO ANY WORK. INSTITUTE OF STEEL CONSTRUC ON(AISC)MANUAL. SUPPORTS SIMILAR MIRO MODEL OR ROOF TO BLOX ON WALKWAY INFORMATION(LIGHT LINE) TREAD PADS.THE USEE OF WOOD FOR SUUPPPP OR IS PROHIBI NEW WORK (HEAVY LINE) Bond Plumbing, LLC 10. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE PLUMBING 25. IF REQUIRED FOR INSTALLATIO OF PIPES AND EQUIPMENT, PROVIDE ADDITIONAL GAS PRESSURE REGULATOR FIXTURES AT HEIGHTS SHOWN ON ARCHITECTURAL ROOM ELEVATIONS. STRUCTURAL MEMBERS BETWE COLUMNS, JOISTS, AND STRUCTURAL FRAME TO 40. ALL ITEMS IN CONTACT WITH POTABLE WATER SHALL COMP VI1H THE NATIONAL R OR DEVICE EXISTING EQUIPMENT ITEM 11. PLUMBING DRAWINGS I��,SHOW APPROXIMATE LOCATIONS OF PLUMBING FIXTURES. MEET SUPPORT REACTIONS FORGES, MOMENTS, DEFLECTIONS). STRUCTURAL "REDUCTION OF LEAD IN DRINKING WATER ACT'S.3874. -- M�--WATER METER �. MEMBERS SHALL BE DESIGNED Y A REGISTERED PROFESSIONAL ENGINEER. OR DEVICE INDICATED REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. COORDINATE FLOOR EXISTING EQUIPMENT OR PIPING 19023 36th Ave W.Suite G DRAINS FOR MECHANICAL SPACES WITH MECHANICAL EQUIPMENT BEING SERVED. : - WYE STAINER TO BE SELECTIVELY DEMOUSHED Lynnwood,WA 98036 P 26. DO NOT CORE DRILL OR DRI THROUGH BEAMS,COLUMNS, AND SHEAR WALLS, PMP-1 12. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL. . UNLESS INDICATED ON STRU TURAL DRAWINGS OR AS APPROVED BY THEWYE CONSTRUCTION INCLUD NG CONCRETE EQUIPMENT PADS,FLASHING DETAILS,ETC. STRUCTURAL ENGINEER. +�-END STAINER WITH CAPPED HOSE 'YL END SLOWDOWN VALVE � TYPICAL EQUIPMENT DESIGNATION `3> IINk��III (PUMP) �I FLANGE UNION POINT OF CONNECTION TO EXISTING THESE DRAWINGS WERE DEVELOPED ABBREVIATI S I� FOR EXCLUSIVE USE D BOND ECCENTRIC REDUCER PLUMBING,LLC ON A DESIGN BUILD AAV AIR ADMITTANCEVALVE EA EACH ,HWS HOT WATER HEATING SU PLY OC ON CENTER SHT SHEET WATER PIPING SYSTEMS CONCEPT.THEY ARE TO BE BOND LY ND o STEAM TRAP WITH WRIT-TEN OF EN PERMISSION OF BOND AC AIR CONDITIONI G EAT ENTERING AIR TEMPERATURE HWR HOT WATER HEATING RE RN OSA OUTSIDE AIR SP STATIC PRESSURE J� WS WATER SERVICE PLUMBING,LLC. FOR INFORMATION ABV ABOVE ECC ECCENTRIC IA INSTRUMENT AIR OAT OUTSIDE AIR TEMPERATURE SPEC SPECIFICATION C. HOSE BIBBS CONTACT: CURTIS BOND. �k CWF. COLD WATER FILTERED AD ACCESS DOOR ECON ECONOMIZER 'ID INSIDE DIMENSION OA OUTSIDE AIR SQ .SQUARE N0. DATE REVISION AFC ABOVE FINISHED CEILING EER ENERGY EFFICIENCY RATIO IE INVERT ELEVATION D OUTSIDE DIMENSION SR SUPPLY REGISTER' -)i HOSE BIBB/WALL HYDRANT .- - COLD WATER(ABOVE FLOOR/GRADE) AFF ABOVE FINISHED FLOOR EF EXHAUST FAN IH INSULATION HOT OPP OPPOSITE SS STAINLESS STEEL AFG ABOVE FINISHED GRADE EFF .EFFICIENT,EFFICIENCY IN INCH,.INCHES OV OUTLET VELOCITY SYS SYSTEM * PIPE ANCHOR _- HOT WATER{ABOVE FLOOR/GRADE) AFUE ANNUALIZED FUEL EFFICIENCY EG EXHAUST GRILLE INFO INFORMATION OCP AWGNMENT GUIDE INDICATED OTHERWISE) OVER CURRENT PROTECTION STAT .THERMOSTAT F TEMPERED WATER IF NOT AHU AIR HANDLING UNIT EL ELEVATION INST INSTRUMENT QU OUTDOOR UNIT TS ^, INDICATED AL ALUMINUM ELEC ELECTRICAL INSUL INSULATE,INSULATION TEMP TEMPERATURE t TEMPERATURE RESSURE 740 .HIGH TEMP HOT WATER 140' APPROX APPROXIMATELY EQUIP EQUIPMENT INV INVERT P PUMP TO TEMPERATURE DIFFERENTIAL TEST PORT/PLTE'S PLUG OR AS INDICATED ARCH ARCHITECTURAL ET ELECTRIC TRACED IRR IRRIGATION(NON POTAB E) PD PRESSURE DROP TDH TOTAL DYNAMIC HEAD FLEXIBLE CONNECTION IN PIPING T TEMPERED WATER ATMOS ATMOSPHERE EXISL(E)EXISTING IU INDOOR UNIT PERF PERFORATED TEMP TEMPORARY `J EXH EXHAUST PF PRE FILTER THRU THROUGH FUNNEL --- HOT WATER CIRCULATING BATT BATTERY EXT EXTERIOR JAN JANITOR PH PHASE TI TENANT IMPROVEMENT - 1/ - SOD .BACK DRAFT JAMPER Pi PUSH ON JOINTS TSTAT .THERMOSTAT NP NON POTABLE WATER N LAT LEAVING AIR EMPERATU BHP BRAKE HORSEPOWER FF FINISHED FLOOR BF BLIND FLANGE F FAHRENHEIT KW KILOWATT PLCS PLACES TYP TYPICAL BFC BELOW FINISHED CEILING ID FIRE DAMPER OR FLOOR DRAIN KWH KILOWATT HOUR PNL VALVES PANEL TRU TERMINAL REHEAT UNIT � WATER METER E PD POINT OF CONNECTION � f f4ff NEAT TRACE FOR COLD WATER PIPE PARTNER IN CHARGE BI BACKWARD INCLINED FLD FLANGED PRV PRESSURE REDUCING VALVE UL - UNDERWRITER'S LABORATORY • BALANCING VALVE SB BLDT UNO SS NOTED ERNSE SOD BOTTOMG FLR OF DUCT -. FCO FLOG CLEAN OUT LC LOCKED LOUND PS PIPE OCKED CLOSED PSV PRESSURE SAFETY(RELIEF) UV UNIT VENTILATOR PRESSURE REGULATING VALVE VENT PIPING PROJECT MANAGER .BTU BRITISH THERMAL UNIT FPM FEET PER MINUTE - - LF UNEAL FEET VALVE UMC UNIFORM MECHANICAL CODE �-- DRAIN WASTE & VE �,• PROJECT ENGINEER BTUH BRITISH THERMAL UNIT PER FLTR FILTER LOC LOCATION UP UNIFORM PLUMBING CODE PRESSURE REDUCING VALVE(PRV) WASTE(ABOVE FLOOR FANG ..I.ON BQ HOUR FOF FACE OF FLANGE LL LANDLORD CITY QUANTITY UBC UNIFORM BUILDING CODE _ e r FPI FINS PER INCH LVG LEAVING UPC UNIFORM PLUMBING CODE ,_ AUTOMATIC CONTROL VALVE-TWO WAY WASTE(BELOW DR)PIPING E ENT PROJECT TEAM MEMBERS CFM CUBIC FEET P R MINUTE R RELIEF J ( JM CHAR CHARACTERI S (SPUNSTRAND) MATL MATERIAL RA RETURN AIR FSK FOIL SKRIM KRAFT LINED DUCT UG UNDERGROUND (ELECTRIC OPERATOR SHOWN) VENT CHECK CHEM CHEMICAL INJE ION FT FEET,FOOT MA MED GAS RED REDUCER V VOLT AUTOMATIC CONTROL VALVE-THREE WAY AW ACID.WASTE DAT � r'�'/}"` "-• BQ CHWS CHILLED WATER SUPPLY- FU FIXTURE UNITS MAX MAXIMUM RED REQUIRED VAC VOLTS AC (ELECTRIC OPERATOR SHOWN) R CHILLED WATER RETURN 0W GREASE WASTE CHW iE FV FACE VELOCITY MPG MEDIUM PRESSURE GAS RR REMOVE AND RELOCATE VDC VOLTS DC ENGINEERS SEAL CLG CEILING FW FEED WATER MA MIXED AIR RJ RESTRAINED JOINTS VD. VOLUME DAMPER IL JR CO CLEAN OUT 'FPTU FAN POWERED TERMINAL UNIT MBH THOUSAND BRITISH THE AL RET RETURN VAC VACUUM BALL VALVE Gro GARAGE DRAIN GONG CONCRETE UNITS PER HOUR RG RETURN GRILLE VAV VARIABLE AIR VOLUME -Do--GATE VALVE C CONDENSATE DRAIN CONN CONNECT OR ONNECTION G GAS MCC MOTOR CONTROL CENTEF RPM REVOLUTIONS PER MINUTE VEL VELOCITY P PUMPED PIPING CPLG COUPLING GALV GALVANIZED MCA MAXIMUM CIRCUIT AMPS RWL RAINWATER LEADER VF VENTILATION FAN GAS COCK CS CARBON STE GEN GENERATOR MAT MIXED AIR TEMPERATUREVFD VARIABLE FREQUENCY DRIVE -O FCO FLOOR CLEANOUT(FOP) CSC CARSEALED CL SED GFl GROUND FAULT MAX MAXIMUM SS SANITARY SEWER VTR VENT THROUGH ROOF � RELIEF VALVE WOO WALL CLEANOUT(WCO) CSO CARSEALED OPEN CIRCUIT INTERRUPTER MECH MECHANICAL STAINLESS STEEL VOL VOLUME CHECK VALVE O VTR VENT THRU ROOF CV. CONSTANT VOLUME GR GRILLE MFR MANUFACTURER SA SUPPLY AIR 'V/PH/HZ VOLTS/PHASE/HERTZ r ® FLOOR DRAIN CW COLD WATER GPM GALLONS PER MINUTE MED MEDIUM SCHED SCHEDULE --{I I BUTTERFLY VALVE 7g1pT,4f' CRD CEILING RADIATION DAMPER GV GATE VALVE MH MANHOLE SECT SECTION W/ WITH �-REDUCED PRESSURE BACKFLOW ASSEMBLY 91 FLOOR SINK 6/15/2023 GW GRAY WATER(NON POTABLE) MIN MINIMUM,MINUTE SEER SEASONAL ENERGY EFF.RATIO WHO WITHOUT L DET DETAIL MISC MISCELLANEOUS SVC SERVICE DFU DRAINAGE FIXTURE UNITS GWR .GLYCOL WATER RETURN MV MED VACUM SHT SHEET W WASTE BALANCING/MEASURING VALVE SHEET INDEX W TITLE GWS GLYCOL WATER SUPPLY SHEET TITLE DIA DIAMETER SO SMOKE DETECTOR WB WET BULB W PLUMBING COVER SHEE WC WATER CLOSET P0.01 PLUMBING COVER SHEET DIM DIMENSION HP HORSE POWER N NORTH,NEUTRAL SL SOUND LINING WGD WALL�I OUT REFERENCE CODES P0•02 PLUMBING SCHEDULES V/ DISCH DISCHARGE HPFS HIGH POINT FINISHED SURFACE NA NOT APPLICABLE SV SOLENOID VALVE MG WATER GAUGE PL00 UNDERGROUND PLUMBING PLAN DI DUCTILE IRON HR HOUR NC NORMALLY CLOSED SW SOCKET WELD WHA WATER HAMMER ARRESTER IBC INTERNATIONAL BUILDING CODE-2018 P1.01 UNDERGROUND ENLARGED PLANS DMPR DAMPER HTG HEATING NIC NOT IN CONTRACT STA STATION IMC INTERNATIONAL MECHANICAL CODE-2018 P200 C PROJECT N0. NO NUMBER OR NORMALLY EN STD STANDARD WT WATER TANK UPC UNIFORM PLUMBING CODE 1 PLUMBING PLAN c E-2018 ON DOWN HT HEIGHT WT WEIGHT IFGC INTERNATIONAL FUEL GAS CODE-2018 P201 LEVEL 1 ENLARGED PLANS 2023-051 DP DIFFERENTIAL RESSURE HVAC HEATING VENTILATION AND AIR NG NATURAL GAS SF SUPPLY FAN WIR W WATER IFC INTERNATIONAL FIRE CODE-2018 P3.00 PLUMBING DETAILS DATE DR DRAIN CONDITIONING NTS NOT TO SCALE SFD SMOKE/RRE DAMPER NEC NATIONAL ELECTRICAL CODE-2017 P4.00 ISOMETRIC RISER DIAGRAMS JUNE 15,2023 DWG DRAWING HW HOT WATER S.I.O. SUPPLIED AND INSTALLED BY WSEC WASHINGTON STATE ENERGY CODE E W PROJECT NETWORK PAT OWNER/OTHER HWC .'HOT WATER CIRCULATING 02 OXYGEN ADA AMERICAN DISABILITY ACT STANDARDS-2010 Received ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS- - A17.1 -2007 W/2008 ADDENDA SAFETY CODE FOR REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER SUN 22023 ELEVATORS AND ESCALATORS 0 O NFPA NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED BAR MEASURES ONE INCH c`1 13D,13R,OR 13(AS APPLICABLE)-2016 HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS ON ORIGINAL DRAWING bLT�� Y4'^ THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE 0��T' ■ - USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. i PLUMBING CALCULATIONS 2018 UNIFORM PLUMBING CODE PER TABLE 702.1 AND TABLE A-2.1 BUILDING SUMMARY MIN.SIZE DOMESTIC WATER WSFU SEWER DFU DOME TIC WATER TRAP/ARM PER HWPER TOTAL PER p/pE ZING TABLE COMMERCIAL ENERGY EFFICIENCY TABLE C404.3.1 as HOT WATER FIXTURE TYPE IN. OTY FIXTURE TOTAL FIXTURE HW FIXTURE TOTAL WSFUB ZINSED G AB UPC CHART A2.7 REFRIGERATOR 1- 1 1 1 - - 0 1 PIPE MA TABLE C403a10. PIPING VOLUME & MAXIMUM , REFRIGERATOR CONNECTION - 1 1 1 - - 0 0 TYPEL OFFER PIPE LENGTHS FLOOR DRAIN-EMERGENCY 2 2 - - - - 0 0 MINIMUM PIPE INSULATION THICKNESS(in. [a] LAVATORY,SINGLE 1.26 2 1 2 0.75 1.5 1 2 FLUSHT NK SINKS _ _ _ - -- - _ _ VELOCI o-gFP3 FLUID OPERATING INSULATION CONDUCTIVITY NO NAL PIPE OR TUBE SIZE(In.) SPECIAL PURPOSE a 1 3 3 z.zs z.zs 3 3 TEMPERATURE VOLUME MAXIMUM PIPING LENGTH(FT.) RANGE AND CONDUCTIVITY MEAN RATING NOMINAL PIPE (F 0'. PER KITCHEN,DOMESTIC 2"DRAIN 1.5 1 1.s 1.5 1.125 1.125 2 2 PS#,00 FT 8 USAGE(F) BtWin/(hW2e'F)[b] TEMPERATURE,T <1 1 TO till 11¢TO<4 4 TO<8 A8 SIZE(IN.) FOOT LENGTH PUBLIC LAV OTHER SERVICE OR MOP BASIN-PUBLIC 20R3 0 3 2.25 -- 3 0 WSFU RANGE MIN MAX FAUCETS FIXTURES/APPLIANCES PI ESIZE 105-140 0.21 -0.28 100 1.0 1. 1.5 1.5 1.5 J1" 1.5 2,0 43.0 PRIVATE,1 GPF,FLUSHOMETER,.75"SUPPLY 2 2 4 8 2 4 1/2 0 4 40-60 0.21 -0.27 75 0.S 0. 1.0 1.0 1.0 �° 3.0 0.5 21.0 WATER CLOSETS _ _ _ _ _ - 314 4.5 11 t 12 22 <40 0.20-0.26 50 0.5 1. 1.0 1.0 1.5 1" 5.0 0.5 13.0 1.6 GPF FLUSHOMETER VALVE,PUBLIC 3 2 5 6. - - 4 6 HV Engineering,Inc. TOTALS 72 28.5 4.875 zo ,va 23 so [a] FOR PIPING SMALLER IRON 1)¢INCHES AND LOCATED IN PARTITIONS I THIN CONDITIONED SPACES, 1Ya" 8.0 0.5 8.0 1 1/2 51 100 REDUCTION OF THESE THICKNESSES SHALL BE PERMITTED(BEFORE TH KNESS ADJUSTMENT REQUIRED IN 1Yz" 110 05 60 Cunsulting Engineers 2 101 205 FOOTNOTE[b . . . ]BUT NOT TO A THICKNESS LESS THAN 1 INCH. Hen Creek oNme Perk COPYRI HT HV ENGINEERING [b] FOR INSULATION OUTSIDE THE SLATED CONDUCTIVITY RANGE,THE MINI UM THICKNESS(T)SHALL BE 2"AND LARGER 18.0 0.5 4.0 6912220th St.SW,Suite 303 2018 UPC APPENDIX A W TER SERVICE CALCULATIONS PIPE MA ERIAL DETERMINED AS FOLLOWS: Mountlake Ten-e,WA 96o43 Gold Watar Ping to one FV System(FV=Flush Valve,FT=Flush Tank) TYPE L PPER T•rl(1 +t/r)"(KA)-11 Phonanvenglneeen ng.6biz Hot Water Piping to be Sized Beon a FT By aMm FV=Flush Valve,FT=Flush Tank) FLUSH T INK '^"^^^' PIPE MAINS FIX UNIT GPM SIZE VELOC �•SFPS WHERE: COLD WATER ze.600 3e SEE PLANS T=MINIMUM INSULATION THICKNESS HOT WATER 4.875 3 SEE PLANS P811100 FT S f=ACTUAL OUTSIDE RADIUS OF PIPE WSFU RANGE MIN MAX t INSULATION THICKNESS LISTED IN THE TABLE FOR APPUCABLE FL ID TEMPERATURE AND PIPE SIZE BLDG SUPPLY PRESSURE(PSI): Pq ESIZE" K CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPS ATURE INDICATED FOR THE Prc6 /2 o a APPLICABLE FLUID TEMPERATURE(Btu4in/hek"2-7)PIPE LOSS BETWEEN BUILDING ANDTENANT SPACE(PS): AVERAGE4 PSI/100'AT 530 FEET TENANT IMPROVEMENT: SUPPLY PRESSURE FOR PIPE SIZING TENANT(PSI): 314 a.s 9 k=THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE ABLE FOR THE APPLICABLE FLUID 1 1D 18 TEMPERATURE. SERVICE MASTERS COLD WATER PRESSURE LOSS: 1 1/4 17 28 [c] FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING,REDUC ION OF THESE THICKNESSES BY% ELEVATION CHANGE(PSI) 4.3 _T 10 _FEET AT 0.433 PSI/FT COPYRIC HT HV ENGINEERING INCHES(38mm)SHALL BE PERMITTED(BEFORE THICKNESS ADJUSTME1 T REWIRED IN FOOTNOTE[b]BUT [_OCatl("I- MIN.RESIDUAL PRESS.AT REMOTE FIXT.(PSI) 30.0 (TYPICALLY PROVIDE 25 PSIG 15 PSIG FOR TXV) PIPE MA RIAL NOT TO THICKNESSES LESS THAN 1 INCH(25mm)). TOTAL PRESSURE LOSS: 34.3 TYPE PPER 17216 51 st Ave NE, .3 34.3 VELOCI -8FPS Industrial Park, Building B 34 AVAILABLE PRESSURE(PSI) 43.7 PS#100 FT 8 Arlington,WA 98223 LONGEST PIPE RUN WITHIN TI(FT) 90.0 43.67 X 100 FT WSFU RANGE MIN MAX f.�Proared For ----_ X 1.25(FITTINGS) 1.25 112.5 113 F7 r E SIZE t' 1 0 3.26 Friction Loss Not b Exceed 38.8 PSIMOOFT LOSS 11/4 4.26 ,2 Bond Plumbing, LLC Size All Piping Based on a FricBo i loss of:O PSIMOOFT LOSS 1 1/2 and max velocity based on installation standa rd. '2 38 135 21/2 138 346 DESIGN MAX FT COPYRI T HV ENGINEERING 19023 36t11 Ave W.Suite G SIZE MAINS AND RISERS PER BELOW PSIMOOFT LOSS PER APRL. Lynnwood,WA 98036 MAIN%LENGTH OF TOTAL PIPE 90% 8 101 RISERSIUNIT PIPING LENGTH OF TOTAL PIPE 10% 8 11 TOTAL ALLOWABLE PSIG FRICTION LOSS 43.7 ACTUAL TOTAL FRICTION LOSS 9.0 SAFETY FACTOR PSIG,MUST BE POSITIVE NUMBER 34.7 NOTE,CALCS CONSERVATIVE BECAUSE NO CREDIT IS T KEN FOR LOUVER THAN MAX FLOW RATES IN EACH PIPE SE ON. THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND PLUMBING.LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND PLUMBING.LLC. FOR INFORMATION PLUMBING FIXTURE SCHEDULE ELECTRIC WATER HEATER SCHEDULE PUMPS EXPANSION TANKS CONTACT: CURTIS BOND. SYMBOL ITEM WASTE VENT CW HW SPECIFICATION REMARKS MARK NUMBER CP-, NO. DATE REVISION WC-IA WATER CLOSET-FLUSH VALVE(ADA) 3 2 1 - BEE CONTRACTOR'S SUBMITTALS 12B GPF EQUIPMENT NUMBER WH-1 SERVICE EQUIPMENT NUMBER ET-1 LOCATION BREAK 1 D8 UR-1A URINAL(ADA) 2 1.1/2 3l4 - SEE CONTRACTOR'S SUBMITTALS 1.O GPF UNIT LOCATION BREAK108 gREq SERVICE SYSTEM 120 DEG LOCATION BREAK 108 SYSTEM SERVED DOMESTIC HOT WATER DOMESTIC SYSTEM DOMESTIC HW LAA LAVATORY(ADA) 1•V2 14/2 112 112 SEE CONTRACTOR'S SUBMITTALS 0.5 GPM TYPE TYPE CARTRIDGE ORIENTATION VERTICAL COUNTER MOUNTED TYPE TANK HEATER SERVICE CONDITIONS S-1 BREAK ROOM SINK 2 1.1/2 1/2 112 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM LINING YES CAPACITY-GPM 2 ASME NO CAPACITY-GALLONS 28 TOTAL HEAD-FT 15 SERVICE CONDITIONS S-2 UTILITY SINK 3 1.1/2 ill 1/2 SEE CONTRACTOR'S SUBMITTALS 1.8 GPM RECOVERY GPH 90 DEG RISE 21 FLUID WATER CAPACITY-GALLONS 6.4 SERVICE CONDITIONS I TEMPERATURE-DEG F 140 DEG F ACCEPTANCE-GALLONS 3.2 IM•1 REFERIGERATOR ICE MAKER CONNECTION 1/2 SEE CONTRACTOR'S SUBMITTALS LVG WATER TEMP-DEG F 140 UNIT CONDITIONS INSULATION NA ENERGY FACTOR SPEED-RPM 3250 FLUID WATER DF-IA DRINKING FOUNTAIN 1.112 1-1/2 1/2 - SEE CONTRACTOR'S SUBMITTALS ELECTRICAL CONNECTIONS INLET/OUTLET 11.SWEAT PRESSURE-PSI 150 NUMBER OF STAGES i I MOTOR TEMPERATURE-DEGF 140 PARTNER IN CHARGE DUAL HEIGHT(ADA) KW INPUT/STAGE 4.5 ENCLOSURE TYPE - UNIT CONDITIONS SB 6/1412023 NOTE 1-COORDINATE FINAL FIXTURE SELECTION WITH OWNER PRIOR TOPROCUREMENT TOTAL KW 4.5 HORSEPOWER-MINIMUM 1/25 INLET 8 OUTLET TAP SIZE 3/4" PROJECT MANAGER VOLTS-PHASE-HERTZ 240M/60 SPEED-RPM 3250 WEIGHT FULL 26 DJ NOTES I11,I21•I31 VOLTS-PHASE-HERTZ 115/80/1 DIAMETER AND HEIGHT 12'k18" PROJECT ENGINEER MISCELLANEOUS PLUMBING EQUIPMENTS REDUCE MANUFACTURER-DESIGN BASIS AMT 2`0 ST-12 BO MANUFACTURER-DESIGN BASIS MAN UFACTURER•DESIGN BASIS TACO 008_BRONZE ID DESCRFTK)N MAKERWDEL CERTIFICATIONS _ REMARKS MAKE RHEEM NOTES Ill REMARKS PROJECT TEAM MEMBERS FG1(E) FLOOR DRAIN(FD) SEE CONTRACTORS SUBMITTALS MEDIUM DUN.8.1/2'ROUND CAST IRON RATE.PIPE SIZE PER PLAN. MODEL XE28SO6ST45U0 REMARKS 6/15/2023 JM EMERGENCY ONLY I SIZE WEIGHT FULUDIAMETERIHEIGHT 303#/23N30" Ill PROVIDE TIMER/AQUASTAT CHECK FOG FLOOR CLEANOUT SEE CONTRACTOR'S SUBMITTALS REMARKS 6/2/2023 BQ I71 MOUNT IN CABINET TMV-i MIXING VALVE SEE CONTRACTORS SUBMITTALS ABBE 1070 POINT OF USE AT LAVS M PROVIDE SEISMIC STRAPS. ENGINEERS SEAL I3] WEIGHT•OPERATING WEIGHT 1� TR TRAPPRIMER SEE CONTRACTOR'S SUBMITTALS PRESSURE ACTIVATED 615/2023 `S A.KUI OF 1T 81812023 PIPING SYSTEM AND SPECIFICATION SCHEI ULE IQUAI.FTt�" SYSTEM OCATION MATERIAL JOINT METHOD REMARKS I PIPE INSULATION 6/15/2023 WASTE 8 VENT BELOWGROUNI SCR.40 PVC(SOLID CORE) SOLVENT WELD ''Lr' DOMESTIC WATER BELOW GROUT COPPER TYPEK BRAZE n PLUMBING SCHEDULES DOMESTIC WATER BELOW GROUN PEX EXPANSION COUPLING WASTE 8 VENT ABOVE GROUN PVC-SCHEDUIF 40 SOLVENT WELD DOMESTIC WATER 2'8 SMALLER ABOVE GROUT COPPER TYPE L SOLDER OR PROPRESS INSULA E PER WSEC NOTES: I- 1.RECIRC LOOP MUST BE INSULATED PER ESDS AND WASHII GTON STATE ENERGY CODE,WHICHEVER IS GREATER. C PROJECT NO. Cm 2023-051 LL DATE JUNE 15,2023 W PROJECT NETWORK PATH a REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INCH 0/� THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRONING L HEREIN,AS AN INSTRUMENT EE PROFESSIONAL SERVICE,IS UTHESE PROPERTY OF HV ENGINEERING,INC.AND IS NOT T BE 0'�THIS P O■ ` USED,IN THOLE OR IN LITHO FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS ' NITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. SERVI' 1 9� TOW TER MAI /// -- -' L ....] -a --'-"" DOME STIC WATER METE I - ............. --I- _._ I I T I ,I F _..: __,:.._ �....... \ PER CITY STANDARD 4US:F 1_ �,...-•�,._ .....,., """ 1 .__...._— _..... _ 1 _ �_ ._... f- - - ,F III--- ____._ ., _ CW SE,VIEE'-tiP'—_—__._ fi"RL -�f _ T RPB I Yn CW U T I•...,, -. f 44. ✓ — TO S i — cw — n p ai. r ngineering,Inc. ... ... .._.._._._....._.. ...._.— ...._._..-- --'--- --'—'--. 7 V UP _ I HV E - _ - .. ... __._—..._-- 1:, � Consulting Engineers - _ Hell Creak OHlce Park M I VY 11P TO I-:D._1 -12 22011 SL SW,Suite 303 POUR STRIP 1 `V (Y� j V ^ �r - V l,l{> N Mountlake Terrece,WA 98043 I 7r I' Phones(206)706-9669 N N (V LLLL wa�1 x N V biz I. FCO c www hveng ti e n9 CF.,� E10W)f INI`'IICD BOOR, TYPICAL r ... ...... ,........___..____.v.,------.._..- ---- 4 PO�- f°0 FCO _.._._.__.__... .... ._._....., C0 I ` TENANT IMPROVEMENT: SC) A�' I I � 54'--2" � I I ;yI F i it SERVICE MASTERS A•W Il I JLOCR CLEAN;CUT I-OR .......:.......:. L J HJIUR TFNINI ST'11B, PYRCAI.. — — — — — — — — — — 't ation L 17216 51 st Ave NE, Industrial Park, Building B Arlington,WA 98223 Bond Plumbing,I tubing, LLC _................. ........,...... ........... I I I I 19023 36th Ave W.Suite G i Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND I PLUMBING,LLC ON A DESIGN BUILD CONCEPT.THEY ARE TO BE USED ONLY / f PCO I !f WITH WRITTEN PERMISSION OF BOND PLUMBING.LLC. FOR INFORMATION CONTACT: CURTIS BOND. I, I - - I I I I i i N0. DATE REVISION I j I III i I i I I � I �I I li ' i. -------------•------ ... ........ ,,,.".......;1..a-�'�...-.C..'�'YVf .,-...... ..."� .—.�......J1�'�"1'''... _�_... �....:,:, ..._. ., .�Ls•. w..YY....'..�. _ —._._ _ ...,. —'-'-�"yr�yr;�1 IN CHARGE _. ARTNER 6"Wd1%� I P B =H4"..L../- O I -B4'+ Lf:.=:F34 1-� 7 \ /� PROJECT MANAGER .i BELOW f lfJl51-IE:C I" R \\ BELOW A HLD FL OR JLOW IINISIiC[).FL(y0f2 BE'IOW FINISHED FI �' / DJ PROJECT ENGINEER T BC PROJECT TEAM MEMBERS 1 _. .. JEC C_ I I HECK I I � I � I -� Bo I II ENGINEERS SEAL 6/15/2023 UNDERGROUND PLUMBING PLAN - WESTERN END W UNDERGROUND SCALE:Xe= 1'-0' TITLE Z UJ PLUMBING PLAN F_ C PROJECT N0. C 2023-051 DA E JUNE 15,2023 �'1W/'� PROJECT NETWOR H K PAT Il REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INCH THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE O" 1" P1 .00 USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING, DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. I I 2 - PI M 1 2"W UP TO FD(0 DFU) I I . 2' 3"W TO LR, PU UP(4 DFU) W UP 3"W..UP TO WCO " 1 V UP(4 FU ) .._ s J."• 2"V UP(4 DFU) _.:.,U-.-..a qFV UP(0 FU !. ,. �^ ` 1WV UP.(0_DFU) 3 ( p ) Engineering,Inc. 3 W(4 D�)� 'W 4 FU W. ' 3-WPC E)8'W I —Enoolneultlnalenaloeen; j 3 W(6 DFU) UP . U p Hall Creek ORlce Perk HV 2"W UP 1 "W P(1 DFU)" I)FW UP(1 DFU) (2 DFU) (2oW '- 6912 220th St.SW,Suite 303 ( Mountlake Terrace,WA 98043 3W( D3" Phone:(206)T06-9889 7 FU) ( DFU) �� 'W 5 DFU) _. (� www.hven9ineerin9.biz I4 I t I — — __— . 1}�"V UP(3 DFU) '. 3"W POC TO(E)6"W n-- I 3"W POC TO(E)6-W 2"W.POC TO(E)6"W 'ff)act — _. I _ .._. �.__ TENANT IMPROVEMENT: t .. I SERVICE MASTERS 1WW UP ........,� YIN UP (1 DFU) ... titian -------- (3 DFU) 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 s(.,(Jared F";; Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY BOND ENLARGED PLUMBING PLAN - UNDERGROUND PLUMBING.LLC ON A DESIGN BUILD 1 MEWS AND WOMEN'S RESTROOMS CONCEPT.THEY ARE TO BE BONDED OF WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC. FOR INFORMATION P1.O1 SCALE: t/y"=1'-0" CONTACT: CURTIS BOND. NO. DATE RENSION PARTNER IN CHARGE SB PROJECT MANAGER DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS JM CHECK BQ ENGINEERS SEAL x 6/15/2023 W ¶'UNDERGROUND UJ ENLARGED PLANS CPROJECT N0. •'es'T".. ,�.._, G 2023.051 DATE JUNE 15,2023 W PROJECT NETWORK PATH a REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INCH Pi ■O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL S ONE HEREIN,AS AN INSTRUMENT EE PROFESSIONAL SERVICE,IS _ _ THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE O�I USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. ' � f I I , I I i , I -4L 1 - 7 -- `, 19 N, }� - N j - - 77 �� � 7, I HV Engineering,Inc. H.Il creek Off]..Perk 3912 220th St.SW,Suite 303 M—t' www.nsk,Tei—,WA 98043 �2�)706 9ee9 pneeNng.blz Pho r , c g t� r ._ F t ' Project TENANT IMPROVEMENT: 3 I SERVICE MASTERS '.. I - - - - - - - '' Location a _ I I I I I 17216 51 st Ave NE, Industrial Park,Building B I I I I I I I Arlington,WA 98223 c ` — - ! ---- -- _. - — Prepared For Bond Plumbing, LLC 19023 36th Ave W.Suite G Lynnwood,WA 98036 ✓'� i I i � I I j I I THESE DRAWINGS WERE DEVELOPED USE BY BOND PLOR EX U BINGO LILC ON A DES GN BUILD n CONCEPT.THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF BOND ---- -- -.. _-_ ___ PLUMBING,L—C. FOR INFORMATION I ( CONTACT: CURTIS BOND. - I NO. DALE REVISION i I ( I I I i ..-- — IPARTNER IN CHARGE III j / PROJECT MANAGER I AL DJ PROJECT ENGINEER ,.I I I BQ \ PROJECT TEAM MEMBERS I , I II JEC aEaT A,� BQ ENGINEERS SEAL 2� 4J � p I oy eAsq x LEVEL 1 PLUMBING PLAN - WESTERN END 6/15/2023 F- u SCALE: Ns=r-o' W TITLE EVEL 1 o z vi PLUMBING PLAN C PROJECT N0. Cm 2023-051 LL DAB JUNE 15,2023 W PROJECT NETWORK PATH 0- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATE OIN ORIGINAL EDRAWINGS ONE NCH P2■00 HEREIN, U AN INSTRUMENT OF PROFESSIONAL SERVICE,IS L THE PROPERTY OF HV ENGINEERING,INC..AND IS NOT TO BE 0'—1' USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. L:I 1)J'CW(13.75 WSFU) (28.5/ 1)j7CW(18.75 WSFU) UON TO RINALS SERVE(2) _ _ h•.w. ,,;; 1 yV1'V(4 DFU) I I .......:. ....._..�.!! . .. .i.. . .... . ... 1)CCW(5.75 WSFU) WHWC \ y; )4'HW 4.875 WSFU) J_ IWCW 24.875 WSFU) V 1 1h- W(22.625 WSFU) ® - ®� FD ® I HV Engineering,Inc. -V(4 DFU) i i 2 C—ure[eg Engineers 'V(4 DFU) ( I .. - Hall Creek St.S Perk 3' POC 0(E) VTR I -ll -- " 881 z sake Br.SW,soma Goa HW 1.125 WSFU) Or✓-- I ---0 1A NnounnekaTarreoa,wABeoaG rW ,- 1)�i CW(19.875 WSFU) I' I! .. _, " .,.. ,,,,,,,,,,,—,,,1 � _ __ _ _ _— -- _ ___—_.,....yl Phone: gi 708-8 B8 —�-- -- —IM —.2"V WALL 2 B �"'°�` `— -- — vrww.hven0lneering•biz 1yJ"CW(20.625 WSFU) 2'V(5 DFU) 1 _L- --- WALL ROUTED IN __ (6 DFU) O. 'V(19DFU) Ir - _- ._..__..._...i _._�... ._..... --_. _ �y------ �i"HW(2.625 WSFU) i`._..._ 2"W D/N/(/4)7 DFU) PY :-xt -=_ u u u 1 'V(32D7. 'S WSFU) II 2 V(1(6 DFU) Y4"HW(0.75 WSFU) TENANT IMPROVEMENT: 5 ET CP SERVICE MASTERS DF 2"V(9 DFU) ..." 1W to Location 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 Prepared For ---.-.-._—. I Bond Plumbing, LLC 19023 36th Ave W.Suite G I I Lynnwood,WA 98036 I I THESE DRAWINGS WERE DEVELOPED ENLARGED PLUMBIN ON D PLAN - 1ST FLOOR FOR EXCLUSIVE BOND PLUMBING,LLC ON A DESIGN BUILD EN'S AND WOMEN' RESTROOMS CONCEPT.THEY ARE TO BE BONDED OF WITH WRITTEN PERMISSION OF BOND PLUMBING,LLC, FOR INFORMATION P2.01 SCALE: 1*-0' CONTACT: CURTIS BOND. NO. DATE REVISION PARTNER IN CHARGE SB PROJECT MANAGER DJ PROJECT ENGINEER BQ PROJECT TEAM MEMBERS JM CHECK BQ ItlM,..,.. ENGINEERS SEAL �OAW�IG 6/15/2023 W TITLE EVEL 1 ENLARGED PLANS C PROJECT NO. G 2023-051 DA E JUTE 15,2023 W PROJECT NETWORK PATH 0- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES P2.01 �■O THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL NCH DRAWING ONE E I L HEREIN,AS AN INSTRUMENT PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE D"—1" USED,IN THOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WTHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING ORATING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. MAX IWCW PIPE 'BRANCH I ADJUSTA LE STRAINEReDRAIN NON-SHRINK GROUT _ _ _ BALL ACCESS DOOR(AT RECESSED r UNION TYP. FINISH LOCATION IN FINISHED SPACES) OFFSET HOT WATER MAIN TO HAND DEPRESS DRAIN 1/4- TO 1/2' FLOOR �I I PPP P2-500 WHERE NOT A EADY SLOPED PRIME RITE TRAP Y�`` SINK/LAVATORY AS NEEDED. PRIMER VALVE / ` MANUFACTURER'S THERMOSTATIC O DISTRIBUTION UNIT TEMPERING VALVE 2 ABOVE FLOORWHERE APPLICABLE - FOR EVRYC MPING RING 20'OF PRIME UNE NOTE: ROUTE HOT WATER PIPING MAINDR COPPER TO FLOOR OVER TO LAVATORY SUCH THAT NO MORE DRAIN,TRAP MAKE UP WATER(TYP.)CITY.AS THAN 2'OF'DEAD`BRANCH PIPE EXISTS. REQUIRED(MAX 2) TYPICAL FOR ALL AND LAVATORIES. PROVIDE TRWATERPROOF HV Engineering,Inc. PRIME AT ALL FLOOR ITYPICAL LAVATORY Consulting EnglneeraLOOR SINKS,AND - -J Hall Creek Office Park DRAINS. 6912 22Gth St.SW,Same 303 Mountlake Terrace,WA 98043 FLOOR DRAIN DETAIL 2 TRAP PRIMER DETAIL n TYPICAL LAVATORY PIPING DETAIL Phona:(206I]069689 =.v(,206.70 r 6 biz P3.00 SCALE: NITS 3.00 SCALE: NTS 3.00 SCALE: NTS ,11 � TENANT IMPROVEMENT: SERVICE MASTERS ..,cation 17216 51 st Ave NE, Industrial Park,Building B Arlington,WA 98223 op,,�jrprl For Bond Plumbing, LLC 19023 36th Ave W.Suite G GATE VALVE(TYPICAL) Lynnwood,WA 98036 UNION(TYPICAL) CIRCULATING PUMP ,.. �CHECK VALVE(TYPICAL) BALANCE VALVE (TYPICAL) W(SIZED PER PLAN) THESE DRAWINGS WERE DEVELOPED ��fKC1 W(SIZED PER PLAN) FOR EXCLUSIVE USE BY BOND INSTALL PER PDI CP PLUMBING,LLC ON A DESIGN BUILD STANDARDS ANQ �4 HWC CONCEPT.THEY ARE TO BE USED ONLY MANUFACTURER S HOT OR COLD ATER SUPPLY IF BRANCH IS GREATER THAN 20' (2 GPM) �" CW/HW/HWC WITHIN 15' WITH WRITTEN PERMISSION OF BOND INSTRUCTIONS LONG,PROVIDE ANOTHER WMA IN OF WATER HEATER TO PLUMBING,LLC. FOR INFORMATION MIDDLE,EACH SIZED FOR HALF BE COPPER(TYP.) CONTACT: CURTIS BOND. PDI THE FIXTURE UNITS ET SIZE PER PLANS NO. DATE REVISION SIZE IF HORIZONTAL BRANCH IS LESS 'A' THAN 20'LONG,PROVIDE ONE EXPANSION) - �WHA AT END OF LINE TANK III SIZE SINGLE FIXTURE STRAP WATER HEATER TANK TO WALL FOR SEISMIC RESTRAINT.TWO PC TO PROVIDE WATER HAMMER RELIEF VALVE,PRESSURE AND PLACES. PPE FIXTURE FIXTURE UNIT T BULATION , TEMPERATURE.PIPE DRAIN FULL SIZEARRESTERS BY SIWX CHIEF UNIT LOA FIXTURE COLD HOT PRECISION PLUMBING PRODUCTS, SIZE TO MOP SINK BELOW A X�' 1-3 WATER CLOSET 8 -- WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING CONSTRUCTION, - SIZE PER PLANS- 8 Y4` 4-12 LAVATORY/HAND SINK 1 1 HAVING PDI/WM-201,ASSE#1010 - AND ANSI/A112.26.1M CERTIFICATION. C 1` 13-25 KITCHEN SINKS 1.5 1.5 INSTALL IN HORIZONTAL OR VERTICAL D tYi 26-50 MOP BASIN 3 3 POSITION,BUT NEVER UPSIDE DOWN. DRAIN VALVE,TYP. INSTALL IN LINE WITH WATER FLOW W.H.DRAIN TO PARTNER IN CHARGE E 1XJ` 51-85 URINAL 5 -- DIRECTION IF POSSIBLE. SIZE THE APPROVED LOCATION R10 INSULATION UNDER SB UNITS AS SHOWN ON THE DRAWINGS TANK PER CODE AND/OR PER THE TABLES SHOWN FLOOR LATFORM� PROJECT MANAGER ABOVE. DRAIN PAN DJ PROJECT ENGINEER BQ 4 WATER HAMMEM ARRESTERS 5 WATER HEATER DETAIL PROJECT TEAM MEMBERS 3.00 SCALE: NTS 3.00 SCALE: NTS JM CHECK BQ ENGINEERS SEAL �oA QUID x sy 6/15/2023 W TITLE SOMETRIC RISER DIAGRAMS PROJECT 10. C 2023-051 DATE JUNE 15,2023 W PROJECT NETWORK PATH 0- REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER M THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRONING BAR MEASURES ONE INC HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE O"�(- 3.00 USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. , f -CW(5.75 WSFU) HV Engineering,Inc. Consulting Eno- 1 „CW 13.7 WSFU Hell Creek ORl—Perk c ) 6912 220th St.SW,Suite 303 �\ M untlake Terrace,69 98043 *-HWC Ph , gi ring.69 N � � \� M g eer ng.bz 1Y4 CW(4 WSFU) I UR -- 1A UR TENANT IMPROVEMENT: to SERVICE MASTERS 1)TCW(18.7 WSFU) /' L 3 to P3.o0 Location 1)FCW(20.625 WSFU) 17216 51 st Ave NE, Industrial Park,Building B (0.75 WSFU) Arlington,WA 98223 IL 1A .HW(2.625 WSFU) S r 1)FCW(21.625 WSFU) Prep-a,s'i r=,r•,T - e Bond Plumbing, LLC `\ 3 - 3.0o IM 19023 36th Ave W.Suite G \�\ 1)¢7Cw(22.625 WSFU. L 1 1)TV(4 DFU) / Lynnwood,WA 98036 1)�"CW P C TO(E)1)h'CW \ 1WCW(24.875 WSFU 1A *-HW(4.875 WSFU `.� 2"V(4 DFU) I I I I THESE DRAWINGS WERE DEVELOPED 1)2°CW(26.5 WSFU `\ j I i �� 2°V(5 DFU) FOR EXCLUSIVE USE BY BOND �- I 1 \`````\`.``i`` ```\`�� CONCERT. TH ORE DESIGNUSE O CONTACT: CURTIS BOND. USED ONLY I WITH WRITTEN PERMISSION OF BOND WC INFORMATION FOR NO. DATE RENSION •' I � � Imo`. Y4-CW i I I DF i 1 WHW Il 1A I I G Y 'A yyH a 2"V(4 DFU) j I 3.00 ET 2 i all-^` . 2°V(6 DFU) i 'A f! 1 3'W(5/D�FU) UR I 3"w(4 DFU) O/. \� 1A 2-W(9 OFU) I - � `" \\\3"W POC TO(E)6-W ' .`\ ' RISER DIAGRAM - 1ST FLOOR ■ ; �`.y' 2°W(4 DFU) PARTNER IN CHARGE MEWS AND WOMEN'S RESTROOMS ; 'A I FD - SB P4.00 SCALE: NONE e i 2V(7 DFU) PROJECT MANAGER ' z'V(16 DFU) DJ PROJECT ENGINEER -1r\3"W POC TO(E)6-W BQ PROJECT TEAM MEMBERS 1 JM 3"W(7 DFU) CHECK BQ 3-W(6 DFU) ENGINEERS SEAL A�I 3'W(4 DFU) 1Y,-V(4 DFU/i 3-W POC TO(E)6-W of Waey C, r ''\2"V(20 DFU j 2-V POC To(E)3-V 6/15/2023 HHH 3-W POC TO(E)6 W "ISOMETRIC 3-w(4 DFU z RISER DIAGRAMS C PROJECT N0. RISER DIAGRAM - 1ST FLOOR • DATE 2023-051 EWS AND WOMEN'S RESTROOMS ^ duNE,S,2023 LJJ PROJECT NETWORK PATH 4.00 SCALE: NONE REUSE OF DOCUMENTS VERIFY SCALE SHEET NUMBER BAR MEASURES ONE INCH w o0 THIS DOCUMENT,AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRONING HEREIN,AS AN INSTRUMENT OF PROFESSIONAL SERVICE,IS 0„-1" THE PROPERTY OF HV ENGINEERING,INC.AND IS NOT TO BE 4■ USED,IN WHOLE OR IN PART,FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING,ADJUST SCALES COPYRIGHT,HV ENGINEERING,INC. ACCORDINGLY. Permit#: 5430 Permit Date: 06/22/23 Permit Type: COMMERCIAL PLUMBING Project Name: Service Master TI Applicant Name: Bond Plumbing LLC Applicant Address: 19023 36th Ave W Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Curtis Bond Phone: 425-422-3484 Email: curtis@bondplumbing.net Scope of Work: Tenant improvement for Service Master- adding restrooms and janitors closet Valuation: 32100.00 Square Feet: 1700 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: Permit Issued: 07/18/2023 Permit Expires: 01/25/2024 Form Permit Type: COMMERCIAL PLUMBING Status: COMPLETE Assigned To: Brittany Harrell Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP ARLINGTON 301 AP 17216 51 STAVE NE AIRPORT INDUSTRIAL - 31052100400100 SUITE 108 INDUSTRIAL N / MANUFACTURING PARKM QOZB, LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Bond Plumbing,LLC Curtis Bond 206-779-7443 1630 215th Street CONSTRUCTION Labor and BONDPPL794MO Sw CONTRACTOR Industries Bond Plumbing,LLC Curtis Bond 206-779-7443 1630 215th Street CONSTRUCTION COA 604 207 260 Sw CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/15/2023 C19.PLUMBING 09/18/2023 09/18/2023 BUILDING Approved FINAL 08/08/2023 C08.PLUMBING 08/09/2023 08/09/2023 BUILDING Approved ROUGH-IN 07/18/2023 C08.PLUMBING 07/19/2023 07/19/2023 BUILDING Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status 06/22/2023 COMMERCIAL BUILDING In Review PLUMBING 06/22/2023 COMMERCIAL No comments,LT&KS PW-ADMIN-GIS Approved PLUMBING 06/22/2023 COMMERCIAL No comments.Class 1.SB PW-SEW-REV Approved PLUMBING 06/22/2023 COMMERCIAL PW-WAT-REV In Review PLUMBING Fees Fee Description Notes Amount Plumbing Commercial Plan Review Table 4-1 $451.39 Processing/Technology $25.00 Plumbing Base Permit Fee $25.00 Drinking Fountain $15.00 Floor Drain $45.00 Kitchen Sink&Disposal $15.00 Laundry Tray $15.00 Lavatory Toilet&Sink Only $30.00 Toilets $30.00 Urinals $30.00 Water Heater(Tank) $25.00 Credit Card Service $21.19 Total $727.58 Attached Letters Date Letter Description 07/18/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/22/2023 XBP Con£ $706.39 147520541 06/22/2023 Curtis Bond 147520541 Kristin Foster $21.19 Outstanding Balance $0.00 Notes Date Note Created By: 06/22/2023 Emailed applicant to verify square footage.Requested hard copy of plans. Brittany Harrell 06/22/2023 Received hard copies.Emailed permit fees to applicant and routed for review. Brittany Harrell Uploaded Files Date File Name 08/01/2023 16369360-20230714 BLD5430 ApprovedPlans.pdf 07/18/2023 16189509-20230718 BLD5430 IssuedPermit.pdf 06/22/2023 15847428-20230621 BLD5430 CommPlumbing Plans.pdf 06/22/2023 15847429-20230621 BLD5430 CommPlumbing Specs.pdf 06/22/2023 15847427-20230621 BLD5430 CommPlumbing App.pdf