HomeMy WebLinkAbout17216 51st Ave Ne Ste 105_BLD5433_2026 i FIRE SPRINKLER PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: ❑ New Installation ✓❑ System Modification ❑ Phased Installation Property Address. 17216 51 st Ave Ne Suite No.: Project Valuation: 13,634.00.00 Lot#: Parcel ID No.: 31052100400100 Preferred Contact: ❑ Owner ❑Applicant ❑ Contractor Project Description: Modify existing system to protect new tenant improvements to walls and ceiling. Owner Name: Smartcap Phone No.: 206-619-4472 Email Address: Kellanne@thesmartcapgroup.com Cell No.: Mailing Address: 8201 164th Ave Ne City: Redmond State: WA Zip: 98233 Applicant Name: Travis Mackey Phone No.: Email Address: Travis.mackey@patriotfire.com Cell No.: 253-361-8603 Mailing Address: 2707 70th ave E City: Tacoma State: WA Zip: 98424 Contractor Name: Patriot Fire Protection Office No.: 253-926-2290 Email Address: Travis.mackey@patriotfire.com Cell No.: 253-361-8603 Mailing Address: 2707 70th ave E City: Tacoma State: WA Zip: 98424 L&I Contractor License Number: PATRIFP099CF Expiration Date: 10/23 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: 0 Complete and Scaled Plans ❑ Hydraulic Calculations Q Equipment Specifications for Each Fire Sprinkler Permit Application ❑ Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ✓❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 300.00 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = 23 $600.00 + $ _ $ Hydraulically Designed Systems Yes 0 No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $625.00 + 1 $ _ $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I - new or existing x $150.00 = $ Class II - new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ PLAN REVIEW FEE $ Processing/Technology Fee $25.00 TOTAL $ I hereby certify that I am the ❑ Owner, ✓❑Applicant, ❑ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Digitally signed by Travis Mackey Travis MackeyDlateP203tlo260842D,CN'TavislMackeyO=Patriot Travis Mackey 6/26/23 Signature Print Name Date SAVE PRINT REV2022 Page 3 0f 3 Bulletin 014 Rev. N co I� R Model F1 FR Series RelQuick Response s 41.bile Glass Bulb Sprinklers z Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model 171 FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent Horizontal Sidewall Model 171 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler :a Types Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Upright en en 1 2 Standard Spray Pendent Model 171 FR40 Sprinkler Types Standard Spray Pendent ; Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 '- Recessed Sprinkler Types : ... Standard Spray Pendent Model F1 FR56LL & F1 FR42LL NSF Certified Low Recessed Concealed Recessed Lead Sprinkler Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- Pendent F1/F2 kler. Product Description 1. Underwriters Laboratories Inc. and Certified for Reliable Model F1 FIR series sprinklers Canada(cULus). 2. FM Approvals (FM) are quick-response automatic sprin- 3. Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. t ij 4. VdS Schadenverhutung GmbH (VdS) Model F1 FR series sprinklers are Stan- 5. NSF Certified to NSF/ANSI Standard 61 Annex G dard Spray sprinklers, with the excep- (NSF) tion of the Model F1 FR56 Conventional XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) tional sprinkler. (EC) The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb.These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers,Automatic&Open (VNIV) times faster than standard response sprinklers. This quick Quick Response Sprinkler response enables the Model F1 FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1 FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model F1 FIR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response, glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1 FIR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3, as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model F1 FIR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model F1 FIR series sprinkler configurations. Concealed Sprinklers Model F1 FR Recessed Pendent and Recessed Horizon- Model F1 FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig. 5, as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1 FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1 FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model F1 and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm)of adjustment, respectively. the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP cov- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm) or 5/8-inch (8mm)of cover cover plate adjustment. In addition, a low profile Model CCP adjustment. Do not install Model F1 FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.Omm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model F1 FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is com- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup. Final adjustment is made F1 FIR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place. Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1 FR56 Concealed Pendent and Model F1 FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with which clasp by hand. Do not use tools to remove bulb protectors. it is not specifically listed my prevent good fire protection and will void all guarantees,warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Listings Orifice Deflector/ Sprinkler Installation Approval Model K-factor Diameter Orientation Height Wrench SIN and Approvals Notes US Metric inches mm inches I mm Pendent 2.25 57 D RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 1 57 GFR2 RA14181 VdS Pendent 2.25 57 D RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 Fi FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1 FRXLH Pendent 2.25 1 57 D RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC F1 FR56 5.6 80 112 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 D RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 D RA1415 cULus, NSF 1 F1 FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA14141 cULus, NSF 6 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Fi FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus, FM 8 Sidewall Fi FR56 5.6 80 112 15 Vertical Sidewall 2 25 57 D RA1485 cULus, FM, 1,2,3,9 (Pendent or Upright) LPCB cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (1)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (1)VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (1)Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (')cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1 FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (1)cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1)The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches(102mm to 305mm). LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C) Max. Model Orientation Temp. Tem . Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp. Rating Temp. Rating Temp. Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus F1 FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1 FR42 Recessed Pendent cULus Upright cULus Fi FR42LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB,VdS, EC Recessed Pendent cULus, FM, LPCB,VdS, EC F1FR56 Concealed Pendent" cULus cULus,VdS,EC cULus Upright cULus, FM, LPCB,VdS, EC "Conventional LPCB,VdS, EC Pendent or Upright)" Pendent -- cULus, NSF - F1 FR56LL Recessed Pendent -- cULus, NSF - Concealed Pendent` -- cULus, NSF - Horizontal Sidewall cULus, FM Fi FR56 Recessed Horizontal cULus, FM Sidewall -- F1FR56 Vertical Sidewall (Pen- cULus, FM, LPCB dent or Upright) * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment Fi FR28 Recessed Pendent cULus cULus cULus RA1411 FlFR40 Recessed Pendent VdS VdS VdS RA1418 F1 FR42 Recessed Pendent cULus cULus cULus RA1413 Fi FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 FlFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1 FR56 Recessed Pendent cULus, LPCB,VdS, cULus, FM, LPCB, cULus,VdS, EC RA1414 EC VdS, EC Fi FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1 FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 114"HOLE DIA. [57.2mm] 1 15116"DIA [49.2mm] l 1" X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS FACE OF FITTING \ // TO FACE OF CEILING DIMENSION F1 ESCUTCHEON II AT MAXIMUM RECESS = 1'T25.4mm] J J AT MINIMUM RECESS = 3/8'[9.5mm] F1 ESCUTCHEON F2 ESCUTCHEON 3/4'[19mm] AT MAXIMUM RECESS = 3/4'[19mm] ADJUSTMENT 0 Vd AT MINIMUM RECESS = 318'T9,5mmi E2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT F1 ESCUTCHEON 118„ AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mmJ AT MINIMUM RECESS = 1-5/8'T41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'T28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] 2 27132"DIA. [72.2mmJ Fig. 1 Model F1 FR56,F1 FR56LL, F1 FR42, F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1" X 1/2" REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE IN CEILING , I 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION - AT MAXIMUM RECESS = 1-1/2'T38mm] AT MINIMUM RECESS = 1'T25.4mm] I AT MAXIMUM RECESS = 9/16'T14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1'T25.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Fig.2 Model F1 FR56, F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'T25.4mmJ AT MINIMUM RECESS = 3/8'T9.5mmJ F1 ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8'T34.9mm] AT MAXIMUM RECESS = 3/4'[19mm] AT MINIMUM RECESS = 2-1/16'[52.4mm] AT MINIMUM RECESS = 318'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mmJ 2 1/4" HOLE DIA. 1/8„ AT MINIMUM RECESS = 2-1/16'T52.4mm] [57.2mm] [3.2mm] 1" X 1/2" REDUCER nl nil 4"-12" 1 15/16 DIA. /hill _ _ _ [101.6mm-304.8mmJ [49.2mrr 2 27/32" DIA. CEILING TO nm [72.2mm] DEFLECTOR nm I TURN COLLAR UNTILTIGHT AGAINST WRENCH BOSS.SPRINKLER `\, F1 ESCUTCHEON 3/4'T 19mm] ADJUSTMENT ESCUTCHEON 1/2'T 12.7mmJ ADJUSTMENT o1 RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MMJ CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW tt- - - + - r 2 518" DIA. 2 5116 DIA — ;J HOLE IN CEILING L_ _J CUP ® V8 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING I 712" MAX. 15116" COVER ADJUSTMENT j COVER PLATE / ASSEMBLY 3 5116" DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FG01A Fig.4 Model F1 FR56/1`1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. I" x 112" REDUCING TEE OR ELBOW _ 2 518" DIA. 2 5116" DIA — HOLE IN CEILING L_ J CUP 00 Vd 1 112" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING 5116" MAX. 514" COVER ADJUSTMENT j COVER PLATE ASSEMBLY 3 5116" DIA. SPRINKLER CONCEALED, 5/16" ADJUSTMENT 017FG02A Fig.5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8.Omm)adjustment-Model CCP cover plate Maintenance Material Data The Model F1 FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA Frame: DZR Brass, OM Brass,or Low Lead Brass 25. Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220, 260,or 510 any other cleaning fluids. Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinkler which has been painted(other than factory applied)or damaged in any way. Cup' CDA Alloy 651 or 693 A stock of spare sprinklers should be maintained to allow Washer: Nickel Alloy 440 or 360, coated with PTFE quick replacement of damaged or operated sprinklers. Adhesive Tape Finishes (1) Bulb: Glass Standard Finishes Sprinkler Escutcheon Cover plateM Bronze Brass Chrome Ordering Information Chrome Plated Chrome White Specify: Polyester Plated 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Coated(4)(5)(6) White Painted I [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Special Application Finishes 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Sprinkler Escutcheon Cover plateM Pendent][U prig ht][Conventional][Horizontal Sidewall] Electroless Nickel Electroless Nickel Bright Brass Bri Recessed Horizontal Sidewall Vertical Sidewall PTFE�'> PTFE g [ ][ ] (3) 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Bright Brass Bright Brass Black Plating Black Plated Black Plated Black Paint 4. Sprinkler Temperature Rating: [135'F (57'C)][155'F Black Paint(2)(6) Black Paint Off White (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] Off White(2)(6) Off White Satin Chrome 5. Sprinkler Finish Chrome Dull Chrome Dull 6. Escutcheon Model: [F1][F2][FP] (1)Other finishes and colors are available on special order. Consult the 7. Escutcheon Finish (where applicable) factory for details.Custom color painted sprinklers may not retain their 8. Cover plate Model: [standard profile CCP 1/2-inch UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, (12.7mm) adjustment][low profile CCP 5/16-inch unless specified otherwise. (2) cULus Listed only. (8.Omm) adjustment] (3) 200°F(93°C)maximum. 9. Cover plate Temperature Rating: [135OF(57°C)for use (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 with Ordinary Temperature sprinklers][165'F (74'C) (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and for use with Intermediate Temperature sprinklers] RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. 10. Cover plate Finish (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. Note: When Model F1 FR Series Recessed sprinklers are ordered, the (6) _PCB and VdS Approved finish applies only to RA1425, RA1414,RA1418 sprinklers and escutcheons are packaged separately. (VdS)and RA1475. (7)cULus listed Corrosion Resistant 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. J011111i, Recycled (800)431-1588 Sales Offices Paper iabld (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.12/15 P/N 9999970300 Bulletin 034 February 2021 Rel Q Model G5 Series Sprinklers Standard Spray, Flat Concealed Pendent Available with Gasketed Cover Plate Features • Standard Coverage,Concealed Pendent(K2.8,4.2,5.6,&8.0 [40,60,80,&115 metric]) • Flat concealed cover plate available in a variety of finishes. • Available with Stainless Steel Clad cover plate(see Table 1). • 3/4-inch(19 mm)cover plate adjustment. • Cover plate available with optional gasket. Model G5 Cover Plate Model G5 Cover Plate Product Description with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response(QR)gasket,or a kfta� Model G5 cover plate with a standard-response(SR)gasket. Model G5 sprinklers with a gasketed cover plate are intended for use in Model G5 Cover Plate dust free environments such as clean rooms. with SR Gasket Model G5 sprinklers must only be used with the Model G5 cover Note:Gasket material is silicone rubber, available in white only. plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary K-Factor Listings Max.Working Sprinkler Sprinkler gpm/ps112 Cover Plate and Sensitivity Pressure Identification Model Wrnlln/bar'1z) Model Approvals psi(bar) Number(SIN) G5 cULus QR SR G5-28 2.8(40) G5 QR Gasket cULus QR 175(12) RA3411 G5 SR Gasket cULus, FM SR 4.2 G5 G5-42 (60) G5 QR Gasket cULus QR 175(12) RA3413 G5 SR Gasket cULus SR G5 cULus QR 250(17) FM, LPCB,VdS, CE SR 175(12) G5-56 (80) G5 QR Gasket cULus QR 250(17) RA3415 G5 SR Gasket cULus SR 250(17) FM SR 175(12) G5 G5-56 300 (80) G5 QR Gasket cULus QR 300(21) RA4014 G5 SR Gasket cULus SR 8.0 G5 G5-80 ($1o) G5 QR Gasket cULus QR 175(12) RA3412 G5 SR Gasket cULus SR G5-80F (8.0) G5 SR Gasket FM SR 175(12) RA3417 www.reliablesprinkler.com StandardModel G5-28 . Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:1/2"NPT or ISO 7-1 R1/2 212°F(100°C) Nominal K-Factor:2.8(40 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table B) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket(cULus only) Levers:Bronze Alloy Model G5 SR Gasket - Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy (See Table I) Towers:Copper Alloy Sprinkler Wrench r Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. ' -- Deflector(retracted)-I A" i Cover Plate Adjustment 3/16"(5 mm) �,����� Pin(extended) Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-28 Sprinkler Sensitivity Listing or Approval Agency Cover Plate Model cULus FM G5 QR SR 7 G5 QR Gasket OR G5 SR Gasket SR SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 2 of 9 February 2021 www.reliablesprinkler.com StandardModel G5-42 . Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:112"NPT or ISO 7-1 Ri/2 212°F(100°C) Nominal K-Factor:4.2(60 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table C) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket ; >n � q Levers:Bronze Alloy Model G5 SR Gasket !; Yoke:Brass Alloy Sealing washer:Nickel with PTFE Cover Plate Finishes Load Screw:Bronze Alloy (See Table I) r Towers:Copper Alloy Sprinkler Wrench s o` Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) Model G5-42 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower 43-5/16- Fusible Link3/4"(19 mm)Max.Deflector(retracted) Cover Plate Adjustment3/16"(5 mm) Pin(extended)Deflector(extended) __ _ Model G4/G5 Cover Plate . Ceiling Model G5-42 Sensitivity Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket OR G5 SR Gasket SR QR: Quick-response SR: Standard-response Bulletin 034 Reliable Page 3 of 9 February 2021 www.reliablesprinkler.com StandardModel G5-56 . Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:1/2"NPT or ISO 7-1 R1/2 212'F(100°C)(cULus,FM,LPCB,CE only) Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure: (See Table D) 175 psi(12 bar) Cover Plates 250 psi(17 bar)(cULus only) Model G5 Material Specifications Model G5 QR Gasket(cULus only) ^- Fusible Link: Beryllium Nickel Model G5 SR Gasket(cULus and FM only) Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Finishes - Yoke:Brass Alloy (See Table I) Sealing washer:Nickel with PTFE Sprinkler Wrench Load Screw:Bronze Alloy Model W3 Towers:Copper Alloy Model FC r Pins:Stainless Steel Listings and Approvals a' d Deflector:Bronze Alloy cULus Listed(Light&Ordinary Hazard only) Cup:Steel FM Approved LPCB Approved VdS Approved[165'F(74'C)only] CE Listed(2831-CPR-S2062) Model G5-56 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower 43-5116"(84mm)Dia.l_� Fusible Link3/4"(19 mm)Max.Deflector(retracted)3c Cover Plate Adjustment3/16"(5 mm) Pin(extended) Deflector(extended) Model G4/G5 Cover PlateCeiling Model G5-56 Sensitivity Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE G5 OR SR SR G5 QR Gasket QR - G5 SR Gasket SR SR QR: Quick-response SR: Standard-response Bulletin 034 Reliable Page 4 of 9 February 2021 www.reliablesprinkler.com Model11 Standard Coverage, • • Pendent Sprinkler1 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74-C) Threads:1/2"NPT or ISO 7-1 R1/2 212°F(100°C) Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure:300 psi(21 bar) (See Table E) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket K Levers:Bronze Alloy Model G5 SR Gasket ' Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE < », (See Table I) Load Screw:Bronze Alloy q o Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. - 3/16"(5 mm) Deflector(retracted) Cover Plate Adjustment Pin(extended) Ili Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 300 Sensitivity F1 el rM Listing or Approval Agency Cover Plate Model cULus G5 QR 7 G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 5 of 9 February 2021 www.reliablesprinkler.com Model :1 Standard Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:3/4"NPT or ISO 7-1 R3/4 212°F(100°C) Nominal K-Factor:8.0(115 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table F) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 QR Gasket Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Sealing washer:Nickel with PTFE Cover Plate Finishes (See Table I) Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench { Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Tower Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) I Cover Plate Adjustment 3/16"(5 mm) Pin(extended) Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80 Sensitivity Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR: Standard-response Bulletin 034 Reliable Page 6 of 9 February 2021 www.reliablesprinkler.com Model :1Standard Coverage,Concealed Pendent Sprinkler SIN RA3417 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165-F(74°C) Threads:3/4"NPT or ISO 7-1 R3/4 212-F(100-C) Nominal K-Factor:8.0(115 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Standard Response Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 SR Gasket Levers:Bronze Alloy Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table I) Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model W3 Pins:Stainless Steel Model FC Deflector:Stainless Steel Listings and Approvals Cup:Steel FM Approved ` Model G5-80F Sprinkler Components and Dimensions 2-5/16" (58 mm) Dia. Threads Body Cup Ceiling Towerit :� -- Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) I Cover Plate Adjustment 3/16"(5 mm) Pin(extended) Deflector(extended) == =x Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80F Sensitivity Listing or Approval Agency Cover Plate Model FM G5 SR GSSR Gasket SR SR:Standard-response Bulletin 034 Reliable Page 7 of 9 February 2021 www.reliablesprinkler.com Installation Dimensions and Cover Plate Information Min.to Max. Min.to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Cover Plate Diameter Hole Diameter in Adjustment to Deflector Temperature Ceiling Distance Rating Model Inch Inch Inch Ceiling(') below Ceiling °F g (mm) (mm) (mm) Inch(mm) Inch (°C) (mm) G5 3-5/16 (84) 135°F(3) G5 QR Gasket(') 3-11/16 (57°C) (94) 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (67) (19) (38 to 57) (6 to 25) or G5 SR Gasket(2) 4 165°F(4) (101 mm) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F(66°C). Cover Plate FinishesM 2) Standard Finishes Special Application Finishes Listing & Approval Agencies White Paint off-White Paint Individual Model G5 series sprinkler may be listed or approved by Chrome(4) Black Paint the following agencies: Custom Color Paint(Specify)(3) Underwriters Laboratories, Inc.and UL Canada(cULus) Raw Brass(Lacquered) Listing Category: Sprinklers,Automatic and Open Bright Brass(4) Guide Number: N V p Finished Bronze 4> FM Approvals(FM) Black Plated Satin Chrome(4) Loss Prevention Certification Board (LPCB) • Stainless Steel Clad') VdS SchadenverhOtung GmbH (VdS) • EC-Certificate of Conformity 0832-CPD-2062(CE) Notes: See Table A and the individual sprinkler data sheets in this Bulletin 1. Paint or any other coating applied over the factory finish will void all for listings and approvals applicable to each sprinkler. approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with QR sealing gasket. Installation 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Application Data Sheets, and the requirements of applicable authorities having jurisdiction. Model G5 series sprinklers must not be Model G5 series sprinklers are standard coverage,flat plate installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets,as well as the requirements of the Model G5 series sprinklers are shipped with a wrench-able applicable approval agencies. protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response Model G5 series sprinklers can be installed without removing (QR)or Standard-response(SR)depending on the approval the wrench-able protective cap using the Model W3 wrench. agency and cover plate selected. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 ReliablE� Page 8 of 9 February 2021 www.reliablesprinkler.com Am Model FC Model W3 For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with without wrench-able cap installed wrench-able cap installed Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup,or the Model FC wrench over the sprinkler than factory applied). Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly.The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.Tighten the sprinkler into the fitting after applying a PTFE Replace any sprinkler which has been damaged.A stock of spare based thread sealant to the sprinkler's threads. Recommended sprinklers should be maintained to allow quick re-placement installation torque is specified in Table J. of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Installation Torque Recommended Installation Guarantee Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, ft.lb N.m and conditions,visit www.reliablesprinkler.com. '/2" NPT or IS07-1 R1/2 8-18 11-24 3/4" NPT or IS07-1 R3/4 14-20 19-27 Patents Do not exceed the maximum recommended torque.Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776,903, U.S. Patent 9,248,327 Install the cover plate by hand,pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap • Model [G5-28] [G5-42] [G5-56] [G5-56 300] both the cover plate and the flange of the skirt. [G5-80] [G5-80F] • Temperature Rating [165°F(74°C)] [212°F(100°C)] Maintenance • Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well • Model [G5, G5 QR Gasket, G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. • Finish(See Table 1) Prior to installation,sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for • Model W3 damage to sprinklers that could cause improper operation or non- • Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without oD touching the sprinkler. rn rn rn rn z Bulletin 034 Reliable Page 9 of 9 February 2021 www.reliablesprinkler.com Availability:Americas Bulletin 213 June 2022 Rel ® RASCOFLEX° Model RFB Sprinkler Connections cULus Listed, FM Approved Product Description RASCOFLEX° Sprinkler Connections are intended to connect a branch line to a sprinkler using a flexible stainless steel hose assembly. RASCOFLEX®Sprinkler Connections are suitable for use in suspended and hard ceiling applications such as T-Bar ceiling grids, wood, metal stud, or hat furring channel hard lid ceilings. Every package contains one(1)fully assembled stain- less steel flexible sprinkler system complete with hose, branch line connection,and sprinkler connection,as well as the pre-as- sembled bracket assembly to attach to the ceiling. RASCOFLEX° Sprinkler Connections are designed for use in hydraulically calculated wet, preaction, or dry sprinkler sys- tems per NFPA 13, 13R, 13D, and FM Global Loss Prevention Data Sheets. Technical Data RASCOFLEX®Model RFB Sprinkler Connections Maximum Working Pressure FM: 200 psi (13.8 bar) UL: 175 psi (12.1 bar) Maximum Working Temperature 300°F(149°C) Ordering Information Inlet/Branch Line 1" NPT Specify: Connections Outlet/Reducer 1/2"or 3/4" NPT Model Name Minimum Allowable UL: 3" (76 mm) • Model RFB Bending Radius FM: 7" (178 mm) Nominal Hose Length Maximum Number of Bends See Friction Loss Chart • 24" (610 mm) 1/2" Outlet 5.6 80 metric : 31" (101 mm) Maximum ( ) 40" (1015 mm) K-Factor 3/4" Outlet 14.0(200 metric) • 48" (1220 mm) • 60" 1525 mm) • 72" (1830 mm) Maintenance Reducer Outlet: 1/2" NPT or 3/4" NPT RASCOFLEX®Sprinkler Connections should be inspected and the sprinkler system maintained in accordance with NFPA 25, Reducer Type as well as the requirements of any Authorities Having Jurisdic- Standard: tion. • 7" (178 mm)straight Optional: • 11-3/4" (300 mm)straight Patents • 7-1/4" (184 mm)elbow RASCOFLEX®Sprinkler Connections may be covered by • 8-5/16" (211 mm)elbow one or more of the following US Patent Nos. 10,173,088 and 10,328,296. Bracket Assembly Length • 24" (610 mm)standard • 48" (1220 mm)optional Listings and Approvals FM Approved Class No. 1637(FM) Accessories • See Table F UL Listed and UL Certified for Canada to ANSI/UL 2443(cULus) www.reliablesprinkler.com Bracket Dimensions 28" [711] Standard or 52" [1320] Optional 1 _ot CEO (D u N Co I LO LO ly LO 1 1 c� Nominal 1-11/16" (43mm)ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. Reducer Dimensions 0 o � - N T T \ T T C) N 00 O') u MM Ln T T T MTM MTM T T T T T 7" (178mm) Straight 11-13/16" (300 mm) 7-1/4" (184mm) Elbow 8-5/16" (211mm) Elbow Standard Straight Bulletin 213 Reliabld Page 2 of 8 June 2022 www.reliablesprinkler.com Installation Dimensions _777- Qi1w,m Nominal 1-11/16" (43mm) ceiling grid shown for reference only. CD Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. T Minimum and Maximum Face of Fitting to Bottom of Ceiling Grid for Each Reducer 7" (178 mm) 11-13/16" 7-1/4" 8-5/16" Straight (300 mm) (184 mm) (211 mm) Standard Straight Elbow Elbow Fig.3 Dimension A Max. Face of Fitting 4" (102 mm) 4" (102 mm) 4" (102 mm) 4" (102 mm) Distance above Bottom of Ceiling Grid Fig.3 Dimension B Max. Face of Fitting 1/8" (3mm) 4-7/8" (124 mm) 3/4" (19 mm) 5/16" (60mm) Distance from Bottom below below above below of Ceiling Grid Note:Based on 1-11/16"(43mm)tall ceiling grid. Fig.3 Dimension C-Clearance Above Ceiling Required at Max.Sprinkler Recess Recessed Escutcheon or Reducer Concealed/Flush Sprinkler 7-1/4" (184 mm) Elbow 8-5/16" (211 mm) Elbow F1 recessed escutcheon NC 7-5/8" (194 mm) F2 or FV recessed escutcheon NC 7-3/8" (187 mm) FP recessed escutcheon 7" (179 mm) 8-1/8" (206 mm) CCP conical concealed cover plate 7" (179 mm) 8-1/8" (206 mm) G4 series concealed sprinklers 8-1/4" (210 mm) 9-1/4" (235 mm) G5 series concealed sprinklers 7-3/4" (197 mm) 8-7/8" (225 mm) RFC series concealed sprinklers 7-1/2" (191 mm) 8-5/8" (219 mm) XL commercial flush sprinkler with flat escutcheon 7-3/8(189 mm) 8-1/2" (216 mm) XL commercial flush sprinkler with conical escutcheon 6-7/8(176 mm) 8" (203 mm) Note:NC-Reducer not compatible with sprinkler adjustment range. Based on 1-11/16"(43mm)tall ceiling grid and flush ceiling tile. Bulletin 213 Reliable Page 3 of 8 June 2022 www.reliablesprinkler.com Materials Figure 4 Number Item Description Material 1 Flexible Hose/Bellow AISI Type 304 Stainless Steel 2 Isolation Ring Nylon 66 3 Gasket EPDM 4 Nut Zinc Plated Carbon Steel 5 Branch Line Nipple(1") Zinc Plated Carbon Steel 6 Reducer Zinc Plated Carbon Steel 7 Braid AISI Type 304 Stainless Steel 8 Welded Collar Fitting AISI Type 304 Stainless Steel , - Bar Stock Zinc Plated SGCC Steel Brackets: Center and Side Zinc Plated SPCC Steel Flexible Hose Number of Bends Figure 5 One Bend Two Bends Three Bends Minimum bend radius 2x 2x Min 1 Min - - bend bend radius radius Minimum I OR OR bend radius � %radiusbend 9Minimum ----- -- radius%radius imum M radius b be Minimum bend radius Note:Do NOT install the RASCOFLEXTM pulled straight or tight.Some flexibility in the form of an allowable bend or bends must be provided. Bulletin 213 Reliable Page 4 of 8 June 2022 www.reliablesprinkler.com c&us cULus Friction Loss Data ' Nominal Reducer Maximum Maximum Equivalent Length Length of Flexible Sprinkler Number of of 1" (33.7mm) Hose K-Factor 90'Bends at 3" Sch.40 Pipe in (mm) NPT Threads Type gpm/psi112 (76mm) (C=120),ft(m) (Ipm/bar12) Bend Radius 24 1/2 Straight 5.6(80) 2 10(3) (610) 3/4 Straight 14.0(200) 2 13(4) 31 1/2 Straight 5.6(80) 3 14(4.3) (790) 3/4 Straight 14.0(200) 3 16(4.9) 40 1/2 Straight 5.6(80) 4 21 (6.4) (1015) 3/4 Straight 14.0(200) 4 23(7) 48 1/2 Straight 5.6(80) 4 24(7.3) (1220) 3/4 Straight 14.0(200) 4 26(7.9) 60 1/2 Straight 5.6(80) 4 25(7.6) (1525) 3/4 Straight 14.0(200) 4 30(9.1) 72 112 Straight 5.6(80) 5 36(11) (1830) 3/4 Straight 14.0(200) 5 33(10.1) UL Notes: 1.Available data for use with 6.1"straight reducers. 2.RASCOFLEX°Sprinkler Connections have been tested and approved by Underwriter's Laboratories, Inc.for use in wet, preaction,and dry sprinkler systems per NFPA 13, 13D, 13R and UL2443. Bulletin 213 Reliable Page 5 of 8 June 2022 www.reliablesprinkler.com FM APPROVED FM Friction Loss Data Nominal Reducer Maximum Maximum Equivalent Length Length of Flexible Sprinkler Number of of 1"(33.7mm) Hose K-Factor 90' Bends at 7" Sch.40 Pipe e in (mm) NPT Threads Type gpm/psi,� 178mm) (C=120),ft(m) (Ipm/bar'12) Bend Radius 1/2 Straight 5.6(80) 1 9.7(2.9) 1/2 90'Elbow 5.6(80) 0 11.5(3.5) 8.0(115) 1 9.9(3) 24 3/4 Straight 11.2(160) 1 9.8(2.9) (610) 14.0(200) 1 9.6(2.9) 8.0(115) 0 10.2(3.1) 3/4 90'Elbow 11.2(160) 0 10(3) 14.0(200) 0 9.8(2.9) 1/2 Straight 5.6(80) 2 12.4(3.8) 1/2 900 Elbow 5.6(80) 2 15.8(4.8) 8.0(115) 2 13.7(4.1) 31 3/4 Straight 11.2(160) 2 12.9(3.9) (790) 14.0(200) 2 12.2(3.7) 8.0(115) 2 14.5(4.4) 3/4 90' Elbow 11.2(160) 2 13.7(4.1) 14.0(200) 2 13(3.9) 1/2 Straight 5.6(80) 2 15.9(4.8) 1/2 90' Elbow 5.6(80) 2 21.6(6.6) 8.0(115) 2 18.5(5.6) 40 3/4 Straight 11.2(160) 2 17.4(5.3) (1015) 14.0(200) 2 16.3(4.9) 8.0(115) 2 20(6) 3/4 90'Elbow 11.2(160) 2 18.9(5.7) 14.0(200) 2 20(6) 1/2 Straight 5.6(80) 3 19.0(5.8) 1/2 900 Elbow 5.6(80) 3 25.9(7.9) 8.0(115) 3 22.7(6.9) 48 3/4 Straight 11.2(160) 3 21.5(6.5) (1220) 14.0(200) 3 20.5(6.2) 8.0(115) 3 24.8(7.5) 3/4 900 Elbow 11.2(160) 3 23.6(7.2) 14.0(200) 3 22.6(6.8) Bulletin 213 Reliable Page 6 of 8 June 2022 www.reliablesprinkler.com FM Friction Loss Data(cont.) Nominal Reducer Maximum Maximum Equivalent Length Length of Flexible Sprinkler Number of of 1" (33.7mm) Hose K-Factor 90' Bends at 7" Sch.40 Pipe NPT Threads Type ,I2 ( in(mm) yp gpm/psi (178mm) (C=120) ft(m) (Ipm/bar'/2) Bend Radius ' 1/2 Straight 5.6(80) 4 23.7(7.2) 1/2 900 Elbow 5.6(80) 4 33.1 (10) 8.0(115) 4 29.1 (8.8) 60 3/4 Straight 11.2(160) 4 28(8.5) (1525) 14.0(200) 4 27(8.2) 8.0(115) 4 32.2(9.8) 3/4 901 Elbow 11.2(160) 4 31.1 (9.5) 14.0(200) 4 30(9.1) 1/2 Straight 5.6(80) 4 28.4(8.6) 1/2 90' Elbow 5.6(80) 4 40.4(12.3) 8.0(115) 4 35.5(10.8) 72 3/4 Straight 11.2(160) 4 34.3(10.4) (1830) 14.0(200) 4 33.2(10.1) 8.0(115) 4 39.5(12) 3/4 90'Elbow 11.2(160) 4 38.3(11.6) 14.0(200) 4 37.2(11.3) FM Notes: 1.RASCOFLEX°Sprinkler Connections have been tested and approved by FM Approvals for use in wet, preaction,and dry sprinkler systems per FM data sheets 2-0,2-5,and 2-8 per FM1637. 2.Differences in equivalent lengths are due to varying test methods, per FM 1637 standards. 3.Above data of friction loss for use with 6.1"straight reducers. Bulletin 213 Reliable Page 7 of 8 June 2022 www.reliablesprinkler.com Accessories List 7-1/4" (184 mm) 8-5/16" (211 mm) 141� : Elbow Reducer-Short Elbow Reducer-Long 1/2": 71VI99003303 1/2": 71VI99003302 3/4": 71VI99003305 3/4": 7M99003304 �d Replacement 7" (178 mm) 11-13/16" (300mm) Standard Straight Straight Reducer Reducer 1/2": 71VI99003309 1/2": 71VI99003308 3/4": 71VI99003328 3/4": 7M99003327 l Y Hat Channel End Hat Channel End Metal Stud End Bracket-Short Bracket- Long Bracket-Short 3" (76mm) 3-3/4" (95mm) 1-1/2" (38mm) 7M99003310 7M99003311 7M99003312 Metal Stud End T-Bar End Bracket- T-Bar End Bracket- Bracket-Long 2-1/16" (53mm) Short 2-5/8" (68mm) Long 4-1/8" (105mm) 7M99003313 7M99003314 7M99003316 Wood Beam Stud Replacement 3" (76 mm) End Bracket I Bend Radius 7M99003317 Center Bracket Indicator 7 M99003321 --- 7M99004179 Replacement Replacement 1" NPT Inlet Adapter #2 Square Drive Bit Gasket 7M99003322 7M99004539 7M99004319 v z 48" (1220mm) Bracket Assembly CO 7M99004840 0 Cn 0 Bulletin 213 Reliabld Page 8 of 8 June 2022 www.reliablesprinkler.com CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17216 51ST AVE NE STE 100 Permit#: 5433 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052100400100 DATE OF ISSUANCE. Scope of Work:Modify existing system to protect new office space. Valuation: 13634.00 OWNER APPLICANT CONTRACTOR SMARTCAP ARLINGTON AIRPORT Patriot Fire Protection PATRIOT FIRE PROTECTION INDUSTRIAL PA 8201 164TH AVE NE STE 110 2707 70th Ave E 2707 70th Ave E REDMOND,WA 98052 Tacoma,WA Tacoma,WA 98424 2533618603 4259262290 LIC:601 269 686 EXP:08/31/2024 LIC:PATRIFP099CF EXP:10/05/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE SPRINKLER CODE YEAR: 2018 STORIES: 1 CONST.TYPE: 11B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. / 7 �1. �,,�y, 08/11/2023 pplicant Signature Date Building Official Date CONDITIONS Adhere to Fire Sprinkler(NFPA)-13D Acceptance Test Checklist.Approved plans shall be onsite during construction.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/11/2023 Processing/Technology $25.00 08/11/2023 Fire System Plan Review $230.69 08/11/2023 Fire Sprinkler System $600.00 08/11/2023 Credit Card Service $25.67 Total Due: $881.36 Total Payment: $881.36 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail HANGER LEGEND A I"U" HOOK B COACH SCREW ROD D BM. CLAMP W "STRAP E EYELET F HDIP G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T 11 X W i I � - Z TIP STATE C_E_R_T_I_FICATION SPRINKLER LEGEND •�OFF CE A [• • • SPRINKLER • Y ,V OFFICE ---- •-'b'------ _-'_•_D OFFICE OFFI E '� g0Fl �pT 6 �4• 6 - ---- XIT I , �g tl E,3 I ORIFICE SIZES ? ? 2 M1 " M1A ENTRY A 1ti SPRAY1- titi L 8 1 � �QB ' i2 2 2 2 2 2 2 2 2 2 ` -- S r K p 3 1 fi 8 16 3 6,'V \ • \ 1ti ti • , I ^ "I T86TSIDEWALL ® , , NEW OUTLET� O z 11 -23-2 - z DRY TYPE II I 1nHEIGFR WALL 9'� RR NEW RASCOFLEX MODELRFB, /2. 1W/MOUNTING BRACKET 2-WAY EARTHQUAKE BRACE TEMP RATING�]+ d-WAY EARTHQUAKE BRACE1 � 2,2• �Q- /2PER PLANLINE STRUCTURE OF PIPEO IN INCHES z LJ LJ LJ LJ LJ LJ LJ 1 LJ LJ LJ • f $ 2B6• I I I I D FITTING LEGEND � 350 ' I I I I gag so0' 1/2• ,/2• P PIPE-O-LET I I I I F PLAIN END FIT FITTIMG APPROVAL REQUIRED -... ,. ..., ., „............. .._..._... SN GROOVED SHAPED NIPPLE CITY OF ARLINGTON I I I I CEILING f SPRINKLER HEAD TSN THREADED SHAPED NIPPLE I I I I I I I I I I I I I TILEf I I I I I I I I I I I I I Q Q o 0 0 0 0 IE IE Al Al TYP.FLEXHEAD DETAIL SPRINKLER HEADS USED I I I I SYM MANUF MODEL TYPE THREAD ORRICE HEAD ESCUTCH TEMP QTY SCALE:NONE SIZE SIZE FINISH DNRN I I I I O TQUARIE HER 56 OR WRIGHT W' K=.6 BRONZE N/A 157 8 C3 W' O �I �I • RENLE 56 GR CONCE40 K�.6 MM WHITE 155' 15 J , FIRE SPRINKLER PLAN " SCALE:Ve"=1'-(f GENERAL NOTES 1. DENOTES EXISTING FIRE SPRINKLER PIPING. rOTAL 23 2. DENOTES NEW FIRE SPRINKLER PIPING. QUAUTY CONTROL BY DATE 3. O DENOTES EXISTING FIRE SPRINKLER TO REMAIN. APPROVED FOR FABRICATION BY DATE 4. 6 DENOTES EXISTING FIRE SPRINKLER TO RELOCATE. 5. SEE HANGER DETAIL FOR TYPICAL HANGER. GENERAL NOTES 1. AL.MATERIAL AND EQUIPMENT To RE HEW AND UL USTED OR FM APPROVED. 2. PING DIMENSIONS IRE CENTER TO CENTER EXCEPT RISERS IND DIMENSIONS LY(I-6)WHICH . 3. EAR11gUN([HBFACIXG SHNL BE PROVIDEO INNACCGRDAHCE WNN HFPA PAMPHLET NO.13.2016 EDITION. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WBN HFPA PAMPHUT NO.13,20AB E RN. PIPING SHALL BF IN ACroRMNCE WITH NFPA PAMPHLET H0.11,20AR EDITION HYDRAULIC INFORMATION ENA BE IN RDAHCE WITH NFPA RANPHUT NO.13.2UtEBTION. EXISTING SYSTEM IS AN ESFR SYSTEM.12 SPRINKLER HEADS 7. OWNER TO PROVIDE AOOQUATE NEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER CALCULATED AT 1,365.4 GPM AT 64.6 PSI SYSTEM TO PREVENT WATER IN PIPES FROST FREEZING. STATIC,89 B. BY ROMIGG FEES CTMGAL DEVICE (IF REQUIRED)TO BE PROVIOEO RESIDUAL,54 9. PAINTING OF PIK R EQUIPMENT(IF REQUIRED)TO RE PROVIDED GPM;3,150 Y oTNEAS 10.MR NO OF PIK B EWIPMOT(IF REWIRED)TO RE PROVIDED -IRS TOLCO FIG.980 SWIVEL C CHANNEL SSWIVELDESIGN CRITERIA SWAY BRACE ATTACHMENT MINIMUM ANGLE FROM W/ x4'/2"LAG SCREW SCOPE OF WORK 1. DESIGN PER NFPA 13 (2016 EDITION). VERTICAL PLANE C STEEL CEILING JOIST MODIFY EXISTING FIRE SPRINKLER SYSTEM FOR T.I.WALLS&CEILINGS. \ •b/N 1n SCH.TIC ADD PIPING TO PROTECT NEW OFFICE AND RESTROOMS. fYB"EYELET UP TO T-7 LONG W YB NUT BOL WASHER SPRINKLER MA1N Approved NCRFA TOLCO FlG/980 TOLCO FIG.1001 S PIPE NOTE ^3/8"ATR SWIVEL SWAY BRACE SWAY BRACE ATTACHMENT �� 1. ALL THREADED PIPE TO BE SCH. BLK. W/TOLCO FIG.4L PIPE CLAMP RING HANGER ©.:I ARingtOn Arlrn{MOn Hel9hiG NO DATE BY REVISIONS DESCRIPTION �Rry¢r. TYP.HANGER DETAIL IN MEZZANINE TYP. BRACING DETAIL IN MEZZANINE ,_, MBBD>"Ws sgoforth 09/12/2023 © ©Pn1N SCALE:NONE SCALE:NONE SmDKey l�n�nc - CONTRACT MM: _ © SMARTCAP DBA PIVOTAL FAdurROOF DECK -_ - � 3� feelW.Y. _ • ®' 8201 164TH AVE NE SUITE 110 �yt REDMOND,WA 98052 .— —. .— � I ]-�Ai EXWT0X00 gCOG1Ca Whole:;:,..: _ WIDE FLANGE BEAM WIDE FLANGE BEAM {� PROJECT NAME: --TOLCO FIG.825 BAR JOIST B IDI DISTRIBUTERS MINIMUM ANGLE FROM W/TOLCO FIG.980 SWIVEL u'TMIS°F T �•'/9/,Rf' nLl•.Q / SWAY BRACE ATTACHMENT Iw DlsTm ARLINGTON, WA 98223 METAL DECK) �MODELL NUMBERSRP20 ANCHOR VERTICAL PLANE 1 11 j - 17216 515T AVE NE AS 1" SCH.40 PIPE __ n 4§"ALL THREAD ROD __ � M/Xy UP TO T-0„ LONG : Ao-o-Aro __..o-o-o-o- aria s ----- ao-o-A.-._..ro-Ano-.,. � c ,. o-o-o- TOLCO FIG. 1001 ... .... ....._...__ ...-_._ -_- ---- A _ sDF,6Qn PIPE RING SWAY BRACE ATTACHMENT - "__________________________ ____________________-�-_____^_ CTOSSm9 PATRIFP099CF COM TOLCO FIG/980 4"-8" SPRINKLER MAIN - 41 P �TR1� WWW PATS OFio EFe.coom NOrih (EOVis.P- p( (F SWIVEL SWAY BRACE B P"rMLn,W, - Map'9"°B FIRE PROTECTION,INC. 2707 70TH AVENUE EAST TEL (253)926-2290 TYP.HANGER DETAIL IN MEZZANINENONE NE DESI TYP.BRACING DETAIL ST ROOF DECK SITE PLAN " VICINITY MAP " TAC MA, WA MAC4 SHEET FAX:(253)922-6150 DATE 6/26/23 FP-1 JOB NO. 12-23373 OF Permit#: 5433 Permit Date: 06/26/23 Permit Type: FIRE SPRINKLER Project Name: IDI Distributers Applicant Name: Patriot Fire Protection Applicant Address: 2707 70th Ave E Applicant, City, State, Zip: Tacoma,WA Contact: Travis Mackey Phone: 2533618603 Email: travis.Mackey@patriotfire.com Scope of Work: Modify existing system to protect new office space. Valuation: 13634.00 Square Feet: 1552 Number of Stories: 1 Construction Type: 1113 Occupancy Group: B; Business ID Code: Permit Issued: 09/05/2023 Permit Expires: 03/03/2024 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP ARLINGTON 310521004001000 17216 51 STAVE NE STE AIRPORT 090 MASTER 105 ADDRESS INDUSTRIAL PARK QOZB,LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# PATRIOT FIRE Megan O'Brien 253 284 3522 2707 70th Ave E CONSTRUCTION COA 601 269 686 PROTECTION CONTRACTOR PATRIOT FIRE CONSTRUCTION Construction PROTECTION Megan O'Brien 253 284 3522 2707 70th Ave E CONTRACTOR Contractor PATRIFP099CF Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/13/2023 FS07.FIRE Fire Sprinkler TI Cover 09/13/2023 09/13/2023 FIRE Approved SPRINKLER FINAL Final<20 heads no hydro Plan Reviews Date Review Type Description Assigned To Review Status 06/29/2023 FIRE SPRINKLER fire sprinkler TI for IFI Distributors FIRE In Review 06/29/2023 FIRE SPRINKLER BUILDING Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-2 $230.69 Fire Sprinkler System Commercial NFPA 13/13R $600.00 Credit Card Service $25.67 Total $881.36 Attached Letters Date Letter Description 08/11/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/09/2023 XBP Conf: $855.69 151178060 08/09/2023 Travis Mackey 151178060 Kristin Foster $25.67 Outstanding Balance $0.00 Notes Date Note Created By: 06/28/2023 Emailed applicant for electronics Raelynn Jones Uploaded Files Date File Name 09/12/2023 16817539-15935134-20230628 BLD5433 Plan Set NCRFAApproved.pdf 09/05/2023 16742114-20230901 BLD5433 IssuedPermit.pdf 06/29/2023 15935132-20230628 BLD5433 Application.pdf 06/29/2023 15935133-20230628 BLD5433 Equip Sub.pdf Permit#: 5433 Permit Date: 06/26/23 Permit Type: FIRE SPRINKLER Project Name: IDI Distributers Applicant Name: Patriot Fire Protection Applicant Address: 2707 70th Ave E Applicant, City, State, Zip: Tacoma,WA Contact: Travis Mackey Phone: 2533618603 Email: travis.Mackey@patriotfire.com Scope of Work: Modify existing system to protect new office space. Valuation: 13634.00 Square Feet: 1552 Number of Stories: 1 Construction Type: 1113 Occupancy Group: B; Business ID Code: Permit Issued: 09/05/2023 Permit Expires: 03/03/2024 Form Permit Type: FIRE SPRINKLER Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning SMARTCAP ARLINGTON 310521004001000 17216 51 STAVE NE STE AIRPORT 090 MASTER 105 ADDRESS INDUSTRIAL PARK QOZB,LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# PATRIOT FIRE Megan O'Brien 253 284 3522 2707 70th Ave E CONSTRUCTION COA 601 269 686 PROTECTION CONTRACTOR PATRIOT FIRE CONSTRUCTION Construction PROTECTION Megan O'Brien 253 284 3522 2707 70th Ave E CONTRACTOR Contractor PATRIFP099CF Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/13/2023 FS07.FIRE Fire Sprinkler TI Cover 09/13/2023 09/13/2023 FIRE Approved SPRINKLER FINAL Final<20 heads no hydro Plan Reviews Date Review Type Description Assigned To Review Status 06/29/2023 FIRE SPRINKLER fire sprinkler TI for IFI Distributors FIRE In Review 06/29/2023 FIRE SPRINKLER BUILDING Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-2 $230.69 Fire Sprinkler System Commercial NFPA 13/13R $600.00 Credit Card Service $25.67 Total $881.36 Attached Letters Date Letter Description 08/11/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/09/2023 XBP Conf: $855.69 151178060 08/09/2023 Travis Mackey 151178060 Kristin Foster $25.67 Outstanding Balance $0.00 Notes Date Note Created By: 06/28/2023 Emailed applicant for electronics Raelynn Jones Uploaded Files Date File Name 09/12/2023 16817539-15935134-20230628 BLD5433 Plan Set NCRFAApproved.pdf 09/05/2023 16742114-20230901 BLD5433 IssuedPermit.pdf 06/29/2023 15935132-20230628 BLD5433 Application.pdf 06/29/2023 15935133-20230628 BLD5433 Equip Sub.pdf