Loading...
HomeMy WebLinkAbout16900 51st Ave Ne_BLD5435_2026 Ferrellgas ALL WORK SHALL BE IN ACCORDANCE WITH PROPANE TANK WIND LOAD NFPA 54-58, NATIONAL FUEL GAS CODE FORCE ON TANK = 0.00256V2•A*Cd AND FLORIDA FUEL GAS CODE 2020 7th ED. = 0.00256(200mph)2 * 41.32ft= * 1.2 — 5078 LBS & FLORIDA BUILDING CODE 2020 7th ED. 2155 Rockfill Rd. TORQUE = 5078 x 2FT = 10156 FT'LBS Fort Myers,FL 33916 TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV, STEEL FORCE ON A" CABLE = (5078 / 1.5FT) / 4 = 847 LBS SCHED. 80 PIPE BOLLARDS (4.0) 6' LONG TENSILE STRENGTH OF J" CABLE = 9800 LBS / 5 = 1960 LHS X 3' BURY DEPTH WITH CAP 0 3' O.C. FORCE ON AUGER ANCHOR = 847 LEIS MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LBO WIND LOAD CERTIFICATION: CODE FBC 2020 / ASCE 7-10 ZO WIND SPEED = 200 MPH, 3 SEC. GUST W EXPOSURE D W INTERNAL PRESSURE COEFF. 0.00 Q C7 O O 8"x16'x4' CONCRETE 7x19 GALV. TYPICAL OF 8 AIRCRAFT CABLE BLOCK ( 4 TOTAL (IN POLY. MIN. — 2 PER LEG) SLEEVE) z STRAPPING BOLT z 0 LP TANK: I Q r:4 1 i i I z W G I I L I hI hI I IT I I hI I I I I I I II I I I I III ITI ITI I I III _ AUGER ANCHOR, 36' LONG W/ 6"0 HEUX Fort Pierce Engineering,Inc. Dependable Mechanical,Electrical 8 TOTAL &Plumbing Design C.A.No.28173 SIDE ELEVATION 315 South 7th Street SCALE 1/4' = 1'-0' Fort Pierce,FL.34950 Phone:772 672-4636 Fax:772 672-4637 8'x16"x4" CONCRETE " 7x19 GALV. BLOCK (TYPICAL OF 8 3 —1� AIRCRAFT CABLE MIN. — 2 PER LEG) (IN POLY. SLEEVE) � + STRAPPING BOLT =c Eric J. Svoboda, PE LP TANK P.E. No. 60982 I I ISSUE DATE: I 1 DRAWN: EJS _—_ — L APPROVED:EJS 1-1 11-1 I I-1 I I-1 I I-1 I I I I-1 I I-1 I 1—= I F_=I I I-1 I I-1 11-111=1 I DRAWING NUMBER AUGER ANCHOR, 36' LONG W/ 6'0 HEUX 8 TOTAL — FRONT ELEVATION SCALE I/4• = r-o' LP500AGR2 ITEM NO, PART NUMBER— DESCRIPTION QTY, V V 6 7579 1 1 4"FILL VALVE 2 8 80-106-01 1 1 4"BALL VALVE 1 9 1 153C NIPPLE 1 1 4"X 4"XH 2 10 B182-S STRAINER'Y' 1 1 4"BRASS 1 11 1153 1 1/4"x Close nipple 1 Hose 1 18 - 1 DE l E 6 W j 27 1151E 4 x6 nipple / 60 28 1193 1 1/4"x 3/4"coupling 1 31 W W-340 3/4"x 3/4"bypass 1 2 52 51 50 6 49 MultiV V Valve TEE 3176 Valve 47 52 1139E 1 1/4"x 3/4"bushing1 54 54 -1 4- 1 4"B II V Iv 1 ® F7 - 1 H E 4'X " RR 1 56 11 7 4 45 cleg. E ow 1 58 1103 1 1 4"9 F ELB W 2 # 1 18 60 T-443 BulkHead Fitting 1 I, 55 i o - m 27 28 23 12 11 � 18 8 58 5 i m Teeco Products Inc. 7471 Reese Road 1-800-225-6621 Sacramento,Ca.95828 PROPRIETARY THE INFORMATION CONTAINED IN Drawn By Date AND THIS DRAWING IS THE SOLE CONFIDENTIAL PROPERTY OF TEECO.ANY REPRODUCTION INPART OR 1-28-08 ASAWHOLEWITHOUTTHEWRIITEN PERMISSION OF TEECO IS PROHIBITED Customer Ske Drawing Number Reviuon Scale Release Date Sheet i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: 0 New Installation ❑ Addition ❑ Alteration ❑ Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 16900 51st Ave NE, Arlington WA Project Valuation: $16,000 Lot#: Parcel ID No.: 31052800100300 Preferred Contact: ❑ Owner O Contractor Project Description: Set a 500g above ground LPG tank with dispenser for filling cylinders Owner Name: Dwayne Paul/Valley Foods Office No.: 360.403.8218 Email Address: dpaul@nationalfoodnw.com Cell No.: 425.407.6216 Mailing Address: 16900 51st Ave NE City: Arlington State: WA Zip: 98223 Contractor Name: Joe Girard/ Ferrellgas LP Office No.: 360.635.2287 Email Address: joegirard@ferrellgas.com Cell No.: 360.635.2287 Mailing Address: 3611 AST SE City: Auburn State: WA Zip: 98002 L&I Contractor License Number: FERRELP055LH Expiration Date: 09/06/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8 ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" Inlet Pressure: Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No. of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Cond.Unit<_100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h x $ 25.00 = $ Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu/h>3hp x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC <_100 Btu/h x $ 15.00 = $ Gas Fired AC >100 Btu/h x $ 25.00 = $ Gas Fired AC > 500 Btu h x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping> 5 units (plus <5 units x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 = $15 mechanical code,not otherwise specified Pkg.Units 5100btu x $ 25.00 = $ Pkg.Units >100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters >100 Btu h x $ 25.00 = $ VAV Boxes (Variable Air Volume,part of air x $ 10.00 = $ conditioning system) Wall Heaters - Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $40 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $65 REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the El Owner, ❑Applicant, ElCon tractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. F Joe Girard Jr Digitally signed by F Joe Girard Jr F Joe e Girard 6/27/23 Date:2023.06.27 15:12:14-07'00' Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of 3 I - � from property fir 00• above • . i LPG tank . . of 38" • . •� • • pr ection i dispenser i 1 i - . - • blocks�, _ Plan Review By This tank is dispensing for internal industrial use. It will not be reselling LPG. City of Arlington 500 gallon above ground LPG tank. Cut sheet attached. Dispenser cabinet with 1 hp pump and motor for dispensing LPG. Cut sheet attached. Concrete "eco block" for crash protection set 3' from the skin of the tank. 2' wide x 2' high x 6' long. Set no more than 40" apart. Weight is 2,600 lbs. Emergency shut-off valve will be mounted on building 21'from dispenser. There will be an 18# BC rated, NFPA qualified,fire extinguisher mounted at the dispenser cabinet. Received Tank will be anchored with 36" long anchors with 6" helix. Detail drawing attached. Dispenser is 15' from the closest property line (shown). It is greater than that to the other three property lines. JUN 2 7 2023 mow+ Tank Location Ll 1 .. f o �� `' CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16900 51STAVE NE Permit#: 5435 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052800100300 DATE OF ISSUANCE. Scope of Work: Set LPG tank and dispenser Valuation: 16000.00 OWNER APPLICANT CONTRACTOR AMAZON.COM SERVICES LLC Ferrellgas LP Ferrell Gas 410 TERRY AVE N 3611 A ST SE 3611 A Street SE SEATTL,WA 98109 Auburn Auburn,WA 98374 3606352287 360-635-2287 LIC:601553542 EXP:09/30/2024 LIC:FERRELP055LH EXP:09/06/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law, or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 09/19/2023 Applicant Signature Date Building Official Date CONDITIONS SEE REDLINED SITE PLAN FOR ADDITIONAL REQUIREMENTS-ATTACHED. SPACING BETWEEN BLOCKS TO BE 36" OR LESS.ADHERE TO APPROVED SUBMITTAL.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECITONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/19/2023 Processing/Technology $25.00 09/19/2023 Mechanical Commercial Plan Review $258.03 09/19/2023 Fuel/LPG $0.00 Total Due: $283.03 Total Payment: $0.00 Balance Due: $283.03 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail z-. CITY OF ARLINGTON 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS: 360-403-3417 - Permit Center: 360-403-3551 BUILDING PERMIT 16900 51ST AVE NE Permit#: 5435 PERMIT EXPIRES 180 DAYS AFTER Parcel #: 31052800100300 DATE OF ISSUANCE. Scope of Work: Set LPG tank and dispenser Valuation: 16000.00 OWNER APPLICANT CONTRACTOR AMAZON.COM SERVICES LLC Ferrellgas LP Ferrell Gas 410 TERRY AVE N 3611 A ST SE 3611 A Street SE SEATTL, WA 98109 Auburn Auburn, WA 98374 3606352287 360-635-2287 LIC: 601553542 EXP:09/30/2024 LIC: FERRELP055LH EXP: 09/06/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC #: EXP: LIC #: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order,proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor_ The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I0/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and c City of Arlington #3101. :�/ �— j, O 09/19/2023 Applic ign Date Building Official Date CONDITIONS SEE REDLINED SITE PLAN FOR ADDITIONAL REQUIREMENTS -ATTACHED. SPACING BETWEEN BLOCKS TO BE 36" OR LESS. ADHERE TO APPROVED SUBMITTAL. APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECITONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/19/2023 Processing/Technology $25.00 09/19/2023 Mechanical Commercial Plan Review $258.03 09/19/2023 FueULPG $0.00 Total Due: $293.03 Total Payment: $0.00 Balance Due: $293.03 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following Information: Permit Number,T�pe of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit#: 5435 Permit Date: 06/27/23 Permit Type: COMMERCIAL MECHANICAL Project Name: LPG Tank set Applicant Name: Ferrellgas LP Applicant Address: 3611 A ST SE Applicant, City, State, Zip: Auburn Contact: Joe Girard Phone: 3606352287 Email:joegirard@ferrellgas.com Scope of Work: Set LPG tank and dispenser Valuation: 16000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/20/2023 Permit Expires: 03/14/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning PAR A OF CITY ARL BLA AMAZON.COM 830 Open Space 31052800100300 16900 51 STAVE NE PROJ FILE NO PLN-439 SERVICES LLC Agriculture RCW REC AFN 201812055003 84.34 Contractors Contractor Primary Contact Phone Address Contractor Type License License# Ferrell Gas Joe Girard 360-635-2287 3611 A Street SE CONSTRUCTION COA 601553542 CONTRACTOR Ferrell Gas Joe Girard 360-635-2287 3611 A Street SE CONSTRUCTION L&I FERRELP055LH CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. Above ground storage tank- 12/15/2023 MECHANICAL 12/19/2023 SafeBuilt Approved FINAL after 9 am Plan Reviews Date Review Type Description Assigned To Review Status 06/28/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Processing/Technology $25.00 Mechanical Commercial Plan Review Table 4-1 $258.03 Fuel/LPG Installation/Removal $0.00 Credit Card Service $8.49 Total $291.52 Attached Letters Date Letter Description 09/19/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/19/2023 XBP Conf: $283.03 154254587 09/19/2023 154254587 Raelynn Jones $8.49 Outstanding Balance $0.00 Notes Date Note Created By: 09/20/2023 Emailed the permit for signature Kristin Foster 09/19/2023 Received COA license information Kristin Foster 07/14/2023 Sent a follow up email for the BL Kristin Foster 07/07/2023 Contractor needs COA business license-emailed info. Kristin Foster 07/07/2023 Emailed for an enlarged aerial view with tank location. Kristin Foster Uploaded Files Date File Name 09/20/2023 16941145-20230920 BLD5435 IssuedPermit.pdf 07/10/2023 16084684-20230707 BLD5435 AerialView.pdf 06/28/2023 15918912-20230627 BLD5435 Drawing.pdf 06/28/2023 15918913-20230627 BLD54351 App.pdf 06/28/2023 15918914-20230627 BLD5435 AnchorDetail.pdf