Loading...
HomeMy WebLinkAbout18318 Smokey Point Blvd_BLD5453_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18318 SMOKEY POINT BLVD Permit#: 5453 PERMIT EXPIRES 180 DAYS AFTER Parcel#:00472500000805 DATE OF ISSUANCE. Scope of Work: Install a new Siplast modified bitumen roof assembly including Valuation:249000.00 new flashing,Prefinished coping metal,through-wall scuppers and integral roof- related components. OWNER APPLICANT CONTRACTOR STILLAGUAMISH GARDENS Commercial Industrial Roofing Commercial Industrial Roofing Iinc 18308 SMOKEY POINT BLVD 3601 121st Street SW 3601 121st St SW ARLINGTON,WA 98223 Lynnwood,WA 98087 Lynnwood,WA 98087 4255342685 425-534-2685 LIC:COMMEI*205JJ EXP:05/16/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL RE-ROOF CODE YEAR: STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: R-1;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 07/14/2023 Applicant Signature Date Building Official Date CONDITIONS APPROVED AS SUBMITTED.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/14/2023 Web Only-Re-Roof Commercial Plan Review $100.00 07/14/2023 Processing/Technology $25.00 07/14/2023 Re-Roof Commercial $2,750.83 07/14/2023 Credit Card Service $86.27 Total Due: $2,962.10 Total Payment: $2,962.10 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i COMMERCIAL RE-ROOF PERMIT APPLICATION ` Community and Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 The building official may allow existing roof coverings to remain when an inspection report and/or analysis prepared by a Washington State licensed structural engineer is submitted to Development Services and reveals all of the following: 1. The roof structure is sufficient to sustain the weight of the additional dead load of the new roofing based on the design values contained in the current International Building Code. 2. The roof deck is structurally sound. 3. Roof drains and drainage are sufficient to prevent extensive accumulation of water. 4. The existing roofing is securely attached to the deck. 5. Existing insulation is not water soaked. 6. Fire-retardant requirements are maintained. 7. No roof shall have in any combination more than that allowed in the current International Building Code. Roofing conforming to the current IBC Section 1507, overlaid on existing roofing shall comply with the provisions of the current IBC,and the manufacturer's installation requirements as an overlay when approved by the Building Official. 8. Per the current Washington State Non-Residential Energy Code,installation of insulation is required if the roofing is torn down to the bare deck. If the roof is torn down to the bare deck,inspection of the deck is also required. See the current Washington State Energy Code regarding the insulation requirements for a semi-heated space. 9. A final inspection and approval shall be obtained from the Building Official when the reproofing is complete. ELECTRONIC FILE SUBMITTAL REQUIREMENTS: 0 Installation Specifications and U.L. Listed Roof Assembly SUBMITTAL REQUIREMENTS,IF INSTALLATION IS OVER EXISTING ROOF COVERINGS: ❑ Installation Specifications and U.L. Listed Roof Assembly ❑ Inspection report and/or analysis prepared by a Washington State licensed structural engineer addressing 1-8 above. Property Address: 18318 Smokey Point Blvd Suite/Unit Number: Lot#: Parcel ID No.: Project Valuation: 249,000.00 Project Scope of Work: Tear-Off Primary Contact: 0 Owner ❑ Applicant ❑ Contractor Owner Name: Stillaguamish Center INC Office No.: Email Address: dklemens@stillycenter.org Cell No.: 360-653-4551 ext 230 Mailing Address: 18308 smokey Point Blvd city:Arlington State: WA Zip: 98223 Applicant Name: Alexander lSaeV Office No.: Email Address: alexander@cir-roofing.com Cell No.: 425-534-2685 Mailing Address: 3601 121 st street SW City:Lynnwood State: WA Zip: 98087 Contractor Name: Commercial Idustrial Roofing INC Office No.: 425-423-0900 Email Address: alexander@cir-roofing.com Cell No.: 425-534-2685 Mailing Address: 3601 121st Street SW City: Lynnwood State: WA Zip: 98087 L&I Contractor License Number: COMMEI*205JJ Expiration Date: 05/31/24 COMMERCIAL RE-ROOF ROOFING INFORMATION Type of Roofing Material: Modified Bitumen Roof Replacing existing sheathing: ❑Yes 0 No Number of Existing Layers: 0 Installation over existing material: ❑Yes El No Roof tear off: 0 Yes ❑ No Class of Roofing: ❑Single Ply Roofing ©Modified Bitumen ❑Liquid Applied ❑Standard Materials ❑Other Self-adhesive sheets, Roofing membrane is Concrete,Clay,Roof Class Examples: TPO,PVE,EPDM hot-mopped asphalt, constructed in place Tiles,Fiberglass torch down,cold- with resin and a Asphalt Composition applied adhesives reinforcing polyester Shingles,Metal Roofs Existing Roof Structure: OSB plywood Existing Roof Material: Modified bitumen system Building Occupancy: ❑ Office/Professional Services ❑ Industrial ❑ Restaurant Retirement Home 0 Other: ❑ Educational Facility ❑ Retail ❑ Religious Facility Provide additional information,as necessary: Removing the existing roofing and related flashing down to the wood deck and dispose of existing prefinished copingunderlayment. Install a new Siplast modified bitumen roof assembly including new flashing, Prefinished coping -wall scuppeis and integial mof-miated components. 1 hereby certify that 1 am the ❑ Owner, El Applicant, ❑ Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington, and the City of Arlington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is complete. ,A Alexander Isaev 6/30/23 Signature Print Name Date SAVE PRINT REV04.2022 f siplast' May 10, 2023 Commercial Industrial Roofing, Inc. Attn: Ian Dugan 3601 121 st St. SW Lynnwood, WA 98087 Email: ian@cir-roofing.com RE: Stilly Valley Center—The Gardens 18308 Smokey Point Blvd. Arlington, WA 98223 Dear Ian: The following is in regard to guarantee eligibility for the above-referenced project. PROJECT TYPE: Tear-off DECK: Plywood SLOPE: 1/4 inch SUBSTRATE PREPARATION: Prime with PA-1125 Primer at a rate of 1 gallon per 100 to 400 square feet. TEMPORARY ROOF: Siplast SA Vapor Retarder, adhered to the primed substrate. INSULATION - BOTTOM LAYER: Paratherm by Siplast, having a thickness of 3.3 inches, mechanically attached simultaneously with the intermediate layer of insulation. INSULATION - INTERMEDIATE LAYER: Paratherm by Siplast, having a thickness of 3.3 inches, mechanically attached using Parafast Fasteners and Metal Plates according to the approved fastening frequency. Increase the fastening frequency by 50% at the perimeter of the roof and mechanically attach the corners at the rate of 1 fastener per 1 square foot (32 fasteners per 4- foot by 8-foot panel). COVER PANEL: DensDeck Prime supplied by Siplast, having a thickness of 1/4 inch, applied in Parafast Insulation Adhesive with 3/4- to 1-inch wide beads spaced on 12- inch centers through the field of the roof, 8-inch centers at the perimeter, and 6-inch centers in the corners. f siplast' ROOF SYSTEM: Paradiene 20 SA, adhered to the cover panel; Paratech 180 Cap FR TG, torch applied. FLASHING SYSTEM: Paradiene 20 SA, adhered to the prepared flashing substrate; Paratech 180 Cap FR TG, torch applied. SUPPLEMENTAL FLASHING SYSTEM: Parapro 123 Flashing System. GUARANTEE TYPE: 15-year Paratech Roof Membrane/System Guarantee The roof must be installed according to the above configuration according to Siplast specifications, recommendations, and details by a Siplast Select Contractor. The guarantee will be issued after all pre- and post-installation procedures are accomplished. Should you require additional information, please do not hesitate to call me. Sincerely, J ep, cam Graff rem Jessica Crabtree Design Services Specialist JC:JD 2 SThTE•pn Q o b a : v. Y s �y't 7A89 a�Y STATE OF WASHINGTON BUSINESS LICENSING SERVICE Thank you for filing online Our processing time generally takes up to 10 business days. Some endorsements may take more time for state or city approval. You will receive your business license with approved endorsements in the mail. An updated business license will be mailed to you when additional endorsements are approved. Confirmation Number: 0-034-222-490 Filing Date and Time: 07/10/2023 09:58:05 AM Payment Method: Card ending in 4193 Business Entity Information Entity Type: Corporation Name of Entity: COMMERCIAL INDUSTRIAL ROOFING, INC. AccountlD: 600346392-001-0001 Firm Name: COMMERCIAL INDUSTRIAL ROOFING, INC. Endorsement(s)Applied For Begin End Count Fee Arlington General Business - 07/10/2023 07/31/2024 1 $60.00 Non-Resident $60.00 Fee Type Begin End Count Fee BLS Processing Fee 07/10/2023 1 $0.00 $0.00 Third-Party Card Processing Fee $1.61 Grand Total: $61.61 txL0004 Permit#: 5453 Permit Date: 06/30/23 Permit Type: COMMERCIAL RE-ROOF Project Name: The Gardens - SVC Arlington Applicant Name: Commercial Industrial Roofing Applicant Address: 3601 121st Street SW Applicant, City, Lynnwood WA 98087 State, Zip: Y ' Contact: Alexander Isaev Phone: 4255342685 Email: Alexander@cir-roofing.com Scope of Work: Install a new Siplast modified bitumen roof assembly including new flashing, Prefinished coping metal, through-wall scuppers and integral roof-related components. Valuation: 249000.00 Square Feet: 6780 Number of Stories: 3 Construction Type: Occupancy Group: R-1; Residential ID Code: Permit Issued: 07/27/2023 Permit Expires: 01/23/2024 Form Permit Type: COMMERCIAL RE-ROOF Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00472500000805 18318 SMOKEY POINT STILLAGUAMISH 125 MULTI- BLUD GARDENS FAMILY AF Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Industrial Alexander Isaev 425-534-2685 3601 121st St SW CONSTRUCTION L&I COMMEI*205JJ Roofing Iine CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 01/02/2024 R00.1 RE-ROOF Please call 30 min prior to 01/04/2024 01/04/2024 BUILDING Approved FINAL arrival Plan Reviews Date Review Type Description Assigned To Review Status 07/03/2023 COMMERCIAL RE-ROOF BUILDING Approved Fees Fee Description Notes Amount Web Only-Re-Roof Commercial Plan Enter 1 if permit is for commercial re-roof $100.00 Review Processing/Technology $25.00 Re-Roof Commercial Table 4.1 $2,750.83 Credit Card Service $86.27 Total $2,962.10 Attached Letters Date Letter Description 07/14/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/10/2023 XBP Conf: $2,875.83 148819578 07/10/2023 99287591 Raelynn Jones $86.27 Outstanding Balance $0.00 Notes Date Note Created By: 12/29/2023 sent expiration notice Hannah Hardwick 07/14/2023 Contractor provided verification of COA business license endorsement. Kristin Foster 07/14/2023 Emailed the permit for signature. Kristin Foster 07/03/2023 Contractor needs COA business license-emailed the info. Kristin Foster Uploaded Files Date File Name 07/27/2023 16325505-20230727 BLD5453 IssuedPermit.pdf 07/03/2023 16027527-20230630 BLD5453 App.pdf 07/03/2023 16027526-20230630 BLD5453 Letter.pdf