HomeMy WebLinkAbout17708 79TH DR NE_BLD20080175_2026 ' 4M BUILDING INSPECTION REPORT G1�Y U�. Permit Address: j r ° I CA `19'~ 1NGSO Contractor: Owner: oc�r�z Ws r% Date: 1 a- l aa13 4 aS-'3,au- �S APPROVAL PARTIAL APPROVAL ® VIOLATION ® CORRECTION REQUEST Corrections listed below MUST BE MADE before work can be approved Please contact inspector __Was not able to perform inspection Call 360-435-0674 FOR RE-INSPECTION by 5:00 pm the day before ' szs&!c, I/ Inspector: A Date: ® Under-floor ® Framing ® Gas Piping ® Footing ® Drywall, nailing ® Consultation ® Foundation ®Shear Nailing ® Groundwork "S Mechanical ® Grid ® Struct. Slab ® Wood Stove ® Rough-in ® Final ® Mason4e-. ® Drainage ® Insulation Ell Other: I % S ©C � l 7z �� ° CITY OF ARLINGTON 238 N OLYMPIC AVE_-ARLINGTON,WA.98223 PHONE:(360)403-3421 Permit#: BLD20080175 BUILDING ' Project Address: 17708 79TH DR NE, ARLMGTON Parcel No: 01047900011400 PROPERTYAPPLICANT OWNER CONTRACTOR RONNEY NELSON RONNEY NELSON NW PERMITS 17708 79TH DR NE 17708 79TH DR NE ARLINGTON,WA 98223 ARLINGTON,WA 98223 Phone: Phone: LICENSE#: EXP Email: Email: PLUMBING CONTRACTOR MECHANICAL CONTRACTOR WESCO 2800 THORNDYKE AVE W SEATTLE,WA 98199 Lic#: Lic#:WASHIES9710D Ex :9/2/2009 JOB DESCRIPTION INSTALL BRYANT 3 TON A/C UNIT VALUATION: $0 PERMIT TYPE:Residential PERMIT GROUP:Mechanical/Solar NUMBER OF STORIES:0 TYPE OF CONSTRUCTION: NUMBER OF DWELLING UNITS:0 OCCUPANT GROUP: CODE:2006 OCCUPANT LOAD: PROPOSEDEXISTINGAREA BASEMENT:0 1 ST FLOOR:0 2ND FLOOR:0 BASEMENT:0 1 ST FLOOR:0 2ND FLOOR:0 3RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 13RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 FRONTSETBACK SIDESETBACK REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICI R HIS/HER DEPUTY AND ALL FEES ARE PAID. -21 ,1/- 7 1e Slgna Print Name 1 ��Date eleased By D e ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.UBC109/IBC110/1RC110. ARCHIVE APPLICANT = ASSESSOR OTHER t 1 ,, • � , - l i BLD20080175 CONDITIONS • None PERMIT FEES De$iip00k, Fee Amount Paid Balance Due C-Plumbing Permit Fee $0.00 $0.00 $0.00 C-Mechanical Permit Fee $35.00 $0.00 $35.00 C-Photocopies $7.00 $0.00 $7.00 Total Due: $42.00 $0.00 $42.00 INSPECTIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. CALL FOR INSPECTIONS BUILDING/ENGINEERING/PARKS/UTILITIES/FINAL(360)435-0674 FIRE(360)403-3607 When calling for an inspection please leave the following information: Permit Number,Job Site Address,Type of Inspection being requested,Contact Name and Phone Number Date Prefereed,and whether you prefer morning or afternoon. • None 07-08-'08 09:57 FROM- T-702 P002/002 F-210 i 07t REsSIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community Development City of Arlington• 238 N Olympic Av%_ • Arlington,WA 98223• Phone (360)403 3431 •FAX(360)403 3447 THIS APPLICATION TO BE USED FOR 01VE AND TWO DWELLING UNITS RESIDENTIAL STRUCTURES, THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS,AND TWO(2) SETS OF WASHINGTON STATE ENERGY C00j�APPLICATIONS. i Type of Permit: Residential ( ) Commercial 1770$79TH DR St',Arlington WA 98223 01047900011400 Project Address: -- - Parcel ID#: — Lot#: Subdivision_ -- — INSTALL BRYANT 3 TON A/C UNIT Project Description, RONNEY NELSON Owner: Phone Number: --------- 17708 79TH DR SE City: Arlington state: WA __ Zip Code: 98223 Address: Y� P ---�— Naida Khari Phone Number: 360-945-2787 Contact Person:Cell Phone: ---- 206-388-9357 Fax: 360-945-20R1 E-mail., naida@nwpermit.com -- 1 Address: 1345 Gulf Road City: Point Robe s __State:Z� Zip Code:"9 Please List quantity of fixtures Below: CLOTHES DRYER FURNACE UP TO 104K BTU GAS OUTLETS ~_ FURNACE OVER 100K FLR PORN INSTALURELOCATE _ SUSPENDED HTRIUNIT HTRI APPL VENT/OTHER APPLIANCE REPAIR BOILER UP TO 3 HP BOILER UP TO 4-15 HP BOLIER UP TO 16.30 HP BOILER UP TO 31-50 HP BOILER 51 HP AND UP AIR AHNDLING UP TO 1OK CFM AIRHANDLING OVER i0K CFM 1 EVAL COOLER VENTILATION PANS _ OTHER VENTILATION SYSTEM VENT HOOD DOMESTIC INCINERATOR COMIIND INCINERATOR -~ ALL OTHER UNITS FREESTANDING STOVE FIREPLACE INSERT Contractor: WESCO Phone Number: 206-378-6644 Address:2800 Thorndyke Ave W City, Seattle State: WA Zip Code: 98199 Contractor's License Number: WASH IES97106 09/02/09 Expiration: — I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will f e in accordance with the laws,rules and regulation of the State of Washington. &L— 0-7/0 SAA Applican signature - oat® - RECEIVED ►►14_ a'u IJUL 0 8 2008 Print A 0 ants Name -— �--- --- - RMIT CENTER CITY OF ARLINGTON BUILDING DEPARTMENT, OFFICE PY APprIn'. fw FormslMEOli•1 DATE 7 _L7_ E;�� —OM O ANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR , � :; _ , � U 1 J ■ i i r � _� ��_ : �,� � � , _ - .. Property Owners Name: / ..fvc: Assess '7,pRrce Site Address:^ 7-j b U Lid: D O Z ----property line Building perimeter Site Plan Man Scalev I"00=26'!f l North I I �e f I ► I I i I I �I I � I �A//�° ��c� I I I rx rf I I I - f RECEIVED JUL 0 8 2008 COA PERMIT CENTER ��� ,J 1 AIR • WITH . 1 RE 1 1 5 NOMINAL1 I ; 1 161 i AProduct Data INDUSTRY LEADING FEATURES/BENEFITS Efficiency 15 SEEW11 - 12 EER Microtube Technology- refrigeration system Indoor air quality accessories available - _ Sound Sound level as low as 74 dBA �llllljlllll�l� ompressor sound blanket Comfort �1II111111 ' System supports Thermidistat, I )�1 thermostat Control or standard llllllllJ)l� t Diagnostics ' TechAssist- with 6-step diagnostics at-a-glance 11111111 - Reliability ' Purone refrigerant - environmentall deplete the ozone layer and low lifetime service ostwon't ' Front-seating service valves ' Scroll compressor A1 • Internal pressure-relief valve ron Pu . LE G1 ,�Y TM ' Internal thermal overload me emmunmemelry suuueem¢eem Low-Pressure switch ' High-pressure switch ' Filter drier Bryant's Air Conditioners with Puron0 refrige rant provide a Balanced refrigeration system for g maximum reliability collection of features unmatched by any other family of equipment. Durability y Air Conditioner model 123A has been designed utii I izing gryaot's DuraCuard` protection Puron refrigerant. The environmentally sound refrigerant allows package: you to make a responsible decision in the protection of the earths Solid,durable sheet metal construction ozone layer. Steel louver coil guard As an Energy Star® Partner, Bryant Heating 8c Cooling has • Baked-on,complete coverage, powder aint determined that this product meets the Energy Starm guidelines for Color matched cabinet screws P energy efficiency. Refer to the combination ratings in the product A Data for system combinations that meet Energy Star® guidelines Applications ' Long line - u p to 250 200 feet condenser bovte total equivalent length, up to evaporator above condenser S or up to 80 ( for more information.) � Long Line Guideline Low ambient(down to-20°F)with accessory y kit Single Phase ' 10-year limited compressor warranty 5-year limited parts warranty RECEIVED 3-Phase 5-year limited Compressor warranty !JUL 0 g 2,(►.1 1-year limited Parts warranty COA PERMIT CENTER i �� - ��'� I I ���J � � � 1 1 NIoUEL NUMBER NOMENCLAT'uRE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 3 A N A 0 3 6 0 0 0 a Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Minor Family Series Series 1=AC 2= 3=13 A=Puron N=206/230-1 A=Standard O=Not 0= 0= A= Legacy SEER P=208/230-3 Defined Not Not Original (Nominal) E=460/3 Defined Defined Series ISO e001:2000 Nron, QMi the environmentally sound refrigerant REa16TERED ✓tile 61N1r1u0 210r100 Unitary Air Cnnditieruw As an Energy Star®Partner,Bryant Heating&Cooling has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Refer to the combination ratings in Product Data forsystem combinations that meet Energy Slat guidelines. STANDARD FEATURES Feature 018 024 030 036 042 048 060 Puron Refrigerant X X X X X X X Up to 15 SEER X X X X X X X Scroll Compressor X X X X X X X Louvered Coil Guard X X X X X X X Field-Installed Filter Drier X X X X X X X Front-Seating Service Valves X X X X X X X Internal Pressure-Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Low-Pressure Switch X X X X X X X High-pressure Switch X X X X X X X Compressor Sound Blanket X X X X X X X TechAssist- Diagnostics-at-a-glance X X X X X X X (Single-Phase Only) 2 .1 PHYSICAL DATA UNIT SIZE—SERIES 018—A 024—A 030—A 036—A 042—A 048—A 060—A Operating Weight(lb) 130 130 142 161 205 228 251 Shipping Weight(lb) 151 151 164 184 233 256 285 Compressor Type Scroll REFRIGERANT Puron®(R-410A)Refrigerant Control TXV(Puron®Hard Shutoff) Charge(lb) 4.25 4.35 4.75 1 5.25 1 6.2 8.35 8.75 COND FAN Propeller Type,Direct Drive Air Dischar ge Vertical Air Qty(CFM) 1880 2200 2200 2950 3170 3365 4050 Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/5 Motor RPM 1100 1100 1100 1100 1100 1100 825 COND COIL Face Area(Sq ft) 9.85 9.85 11.49 14.77 17.25 21.56 25.15 Fins per In. 20 20 1 25 25 25 25 25 Rows 1 1 1 1 1 1 1 1 Circuits 3 3 1 3 3 4 5 5 VALVE CONNECT.(in.ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES*(In.OD) Vapor(0-80 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1-1/8 Liquid(0-80 Ft Tube Length) 3/8 •For tubing sets between 80 and 200 ft.horizontal or 20 ft,vertical dillerential(250 ft.Total Equivalent Length),consult the tong Line Guideline. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON REFRIGERANT 1-STAGE AIR CONDITIONER APPLICATIONS LONG LINE APPLICATION:An application is considered"long ft. when the outdoor unit is below the indoor unit. Refer to line"when the total equivalent tubing length exceeds 80 ft or when Accessory Usage Guideline for required accessories. See Long there is more than 20 ft. vertical separation between indoor and Line Application Guideline for required piping and system outdoor units.These applications require additional accessories and modifications. Also, refer to the table below for the acceptable system modifications for reliable system operation. The maximum vapor tube diameters based on the total length to minimize the allowable total equivalent length is 25017t. The maximum vertical cooling capacity loss. separation is 200 Ft when outdoor unit is above indoor unit,and 80 UNIT ACCEPTABLE ACCEPTABLE COOLING CAPACITY LOSS(%) NOMINAL LIQUID LINE VAPOR LINE TOTAL EQUIVALENT LINE LENGTH(FE.) SIZE DIAMETERS DIAMETERS Standard Application Long Line Ap dication Requires Accessories (BTUH) (IN.OD) (IN.OD) 25 50 e0 so+ 100 125 150 175 200 225 250 18000 1/2 1 2 3 3 -_ 4 8 1 Stage 3/8 Puron AC 1 5/8 0 0 1 1 1 1 I 2 2 3 3 3 24000 5/8 0 1 1 1 2 3 3 4 4 5 6 1 Stage 3/8 3/4 0 0 0 0 0 1 1 1 1 1 2 Puron AC 7 0 0 0 0 0 0 0 1 0 0 0 1 30000 5/8 1 2 3 3 3 4 5 6 7 8 9 1 Stage 3/8 3/4 0 0 1 1 1 1 2 2 2 9_i 3 Puron AC 718 0 0 0 0 0 1 1 1 1 1 1 1 36000 5/8 1 2 4 4 5 6 7 _9 10 11 1 1 Stage 3/8 3/4 0 0 1 1 1 2 2 �$ •y 3 Puron AC 7/8 0 0 0 0 0 j 1 " 1 42000 3/4 0 1 2 2 _2 4 4 5 6 6 1 Stage 3/8 7/8 0 0 1 1 1 2 2 2 3 3 Puron AC 1 1/8 0 0 0 0 0 0 0 0 0 1 48000 3/4 0 1 2 2 3 5 5 6 7 8 1 Stage 3/8 7/8 0 0 1 1 1 2 2 3 3 4 Puron AC 1 118 0 0 0 0 0, 0 0 0 1 1 1 60000 3/4 1 2 4 4 5 1 6 7 1 9 10 11 12 1 Stage 3/8 7/8 0 1 2 2 2 3 4 4 1 5 5 6 Puron AC 1 1/8 b 0 0 0 1 1 1 1 1 1 1 1 1 2 tan a ngt = or ess to eriutva vent lengiF — — NMI 11qffl1N:ffMF*_n reComtnendWon Long Line AppiiC'a—f"iWGuideline,� Applications in this area may have height restrictions that limit allowable total equivalent length,when outdoor unit is below indoor un Lcnq Line Application Guideline. 3 ACCESSORIES ORDER SIZE-SERIES,(VOLTAGE) NUMBER DESCRIPTION 018-A 024-A 030-A 030-A 036-A 036-A 036-A 042-A 042-A 042-A 048-A 048-A 048-A 060-A 060-A 060-A (N) (NI (N) (P) (N) (P) (E) IN) (P) (E) IN) (P) (E) IN) (P) (E) KAACH1201AAA CRANKCASE HTR X X X X X X KAACH1301AAA CRANKCASE HTR X X X KAACH1401AAA CRANKCASE HTR X X X X X X KAACH1501AAA CRANKCASE HTR X KSACY0101AAA CYCLE X X X X X X X X X X X X X X X X PROTECTOR KAAFT0101AAA FREEZE X X X X X X X X X X X X X X X X THERMOSTAT KSAHS1701AAA HARD START X X X X X X X (CAP/RELAY) KSALA0301410 LOW AMBIENT PSW X X X X X X X I X X X X X X X X X HC32GE234 MOTOR FAN BALL X BEARING 230V HC34GE239 MOTOR FAN BALL X X X BEARING 230V HC38GE228 MOTOR FAN BALL BEARING 230V X X HC40GE226 MOTOR FAN BALL X X BEARING 230V HC40GE228 MOTOR FAN BALL BEARING 230V X X X X KSALA0601AAAMOTORMASTER 230V X X X X X X X X X X X X HC40GE466 MOTOR FAN BALL X BEARING 460V iHC38GE462 MOTOR FAN BALL BEARING 460V X HC40GE467 MOTOR FAN BALL BEARING 460V X X KSALA0701AAA MOTORMASTER460V X X X X KAALS020I LLS SOLENOID VALVE X X X X X X X X X X X X X X X X KAACS0201 PTC START ASSIST PTC X X X X X X X KSASF0101AAA SUPPORTFEET X X X X X X X X X X X X X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X X X X X X X X X X KSATX0201 PUR TXV PURON HSO X X X X KSATX0301 PUR TXV PURON HSO X X X X X X IKSATX0401 PUR TXV PURON HSO X X X KSATX0501PUR TXV PURON HSO X X X KAAWS0101AAA WINTER START X X X X X X X X X X X X X X X X x=A00MOry ACCESSORY THERMOSTATS THERMOSTAT/SUBBASE PKG. DESCRIPTION TSTATBBPRH01-B Thermidistat Control-Programmable/Non-Programmable Thermostat with Humidity control TSTATBBPAC01-B Thermostat-Auto Changeover,7-Day Programmable,°F/°C,1-Stage Heat,1-Stage Cool TSTATBBNAC01-C Thermostat-Auto Changeover,Non-Programmable,°F/°C,1-Stage Heat,1-Stage Cool TSTATBBBAC01-B Builder's Thermostat-Manual Changeover,Nan-Programmable,°F/°C,1-Stage Heat,1-Stage Cool TSTATBBSEN01-B Outdoor Air Temperature Sensor TSTATXXBBP01 Backplate for Builder's Thermostat TSTATXXNBP01 Backplate for Non-Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat TSTATXXCNV70 Thermostat Conversion Kit(4 to 5 wires)-10 Pack 4 ACCESSORY USAGE u6IDELINE REQUIRED FOR LOW-AMBIENT REQUIRED FOR REQUIRED FOR ACCESSORY COOLING APPLICATIONS LONG LINE SEA COAST (Below 55'F) APPLICATIONS* APPLICATIONS (Over 80 ft.) (Within 2 miles) Ball Bearing Fan Motor Yest �No No Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Liquid-Line Solenoid Valve No See Long Line No Application Guideline Motor Master"Control or Low-ambient Pressure Switch Yes No No Thermostatic Expansion Valve(TXV) H Yes Yes Yes Hard Shutoff Support Feet Recommended No Recommended Winter Start Control Yes No No •For tubing line sets between 80 and 200 ft.and/or 20 it vertical ditferential(250 ft.Total Equivalent Length),refer to Residential Split-System Long Line Application Guideline. t Required for Low-Ambient Controller(full modulation MotorMaster®Control only). Accessory Description and Usage (Listed Alphabetically) 1.Ball-Bearing Fan Motor 6.Evaporator Freeze Thermostat A fan motor with ball bearings which permits speed reduction An SPST temperature-actuated switch that stops unit operation while maintaining bearing lubrication. when evaporator reaches freeze-up conditions. Usage Guideline: Usage Guideline: Required on all units when using MotorMasterO Required when Low-ambient kit has been added. 2.Compressor Start Assist-Capacitor and Relay 7.Low-Ambient Pressure Switch Kit Start capacitor and relay gives a"hard"boost to compressor motor A long life pressure switch which is mounted to outdoor unit at each start up. service valve.It is designed to cycle the outdoor fan motor in order Usage Guideline: to maintain head pressure within normal operating limits. The Required for single-phase scroll compressors in the control will maintain working head pressure at low-ambient following applications: temperatures down to 0°F when properly installed. Long line Usage Guideline: Low-ambient cooling A Low-Ambient Pressure Switch must be used when Suggested for all compressors in areas with a history of cooling operation is at outdoor temperatures below55°F(12.8°C)to a minimum of 0°F(-17.8°C) low voltage problems. Suggested for all commercial applications. 3.Compressor Start Assist—PTC Type Solid state electrical device which gives a "soft" boost to the 8.MotorMaster®Low-Ambient Controller compressor at each start-up. A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the Usage Guideline: saturated, condensing temperature during operation in cooling Suggested in installations with marginal power supply. mode only.For outdoor temperatures down to-20°F(-28.9°C),it 4.Crankcase Heater maintains condensing temperature at 100°F ±10°F (37.8°C An electric resistance heater which mounts to the base of the -12°C). compressor to keep the lubricant warm during off cycles.Improves Usage Guideline: compressor lubrication on restart and minimizes the chance of A MotorMasterO Low Ambient Controller or liquid slugging. Low-Ambient Pressure Switch must be used when Usage Guideline: cooling operation is used at outdoor temperatures Required in Low-ambient cooling applications. below 55°F(12.8°C). Required in long line applications. Suggested for all commercial applications. Suggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling.This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage,protector control trip,thermostat jiggling, or normal cycling. 5 Accessory Description and Usa.)(Listed Alphabetically) (Cont) 9.Outdoor Air Temperature Sensor 11.Thermostatic Expansion Valve(TXV) Designed for use with Carrier Thermostats listed in this A modulating flow-control valve which meters refrigerant liquid publication. This device enables the thermostat to display the flow rate into the evaporator in response to the superheat of the outdoor temperature.This device also refrigerant gas leaving the evaporator. is required to enable special thermostat features such as auxiliary Kit includes valve,adapter tubes,and external equalizer tube.Hard heat lock out. shutoff types are available. Usage Guideline: NOTE: When using a hard shutoff TXV with single phase Suggested for all Carrier thermostats listed in this reciprocating compressors, a Compressor Start Assist Capacitor publication. and Relay is required. 10.Support Feet Usage Guideline: Four stick-on plastic feet that raise the unit 4 in. above the Accessory required to meet ARI rating and system mounting pad. This allows sand, dirt, and other debris to be reliability,where indoor not equipped. flushed from the unit base,minimizing corrosion. Hard shutoff TXV or LLS required in air conditioner Usage Guideline: long line applications. Suggested in the following applications: Required for use on all zoning systems. Coastal installations. 12.Time-Delay Relay Windy areas or where debris is normally circulating. An SPST delay relay which briefly continues operation of indoor Rooftop installations. blower motor to provide additional cooling after the compressor For improved sound ratings. cycles off. NOTE: Most indoor unit controls include this feature. For those that do not,use the guideline below. Usage Guideline: Accessory required to meet ARI rating,where indoor not equipped. 13. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. 6 :1.' ELECTRICAL DATA MIN MIN MAX MAX MAX UNIT SIZE OPER COMPR FAN WIRE WIRE LENGTH LENGTH FUSE** -SERIES V/PH VOLTS* MCA SIZEt SIZEt (FT)# (FT)# or CKT (VOLTAGE) BRK MAX MIN LRA RLA FLA 60,C 75°C 60°C 75°C AMPS 018-A(N) 48.0 9.0 0.5 11.7 14 14 67 64 15 024-A N) 58.3 13.5 0.75 17.6 14 14 45 43 25 030-A(N) 64.0 12.8 0.75 16.8 14 14 47 45 25 036-A(N 208-230-1 253 197 77.0 14.1 1.4 19.0 12 12 66 63 30 042-A(N) 112.0 17.9 1.1 23.5 12 12 53 51 40 048-A(N) 109.0 19.9 1.4 26.2 10 10 76 73 40 060-A(N) 134.0 26.4 1.2 34.2 8 8 91 86 50 030-A(P) 58.0 10A 0.8 13.4 14 14 68 65 20 038-A(P) 71.0 9.2 1.4 12.9 14 14 70 67 20 042-A(P) 208/230-3 253 197 88.0 13.5 1.2 18.1 12 12 80 76 30 048-A( 83.1 13.6 1.2 18.2 12 12 79 76 30 060-A(P) 110.0 17.7 1.2 23.3 12 12 62 59 40 036-A 38.0 5.6 0.7 7.8 14 14 233 222 15 042-A 44.0 6.0 0.5 8.0 14 14 227 216 15 048-A E) 460-3 506 414 41.0 6.1 0.6 8.2 14 14 222 211 15 O60-A{E 52.0 7.8 0.6 10.3 1 14 14 1 177 168 15 • rmissible mite of the voltage range at which the unit will operate satisfactorily t If wire is applied at ambient greater than 30°C(86'F),consult table 310-16 of the NEC(ANSI/NFPA 70). The ampacity of non-metallic-sheathed cable (NM),trade name ROMEX,shall be that of 60°C(140°F)conditions,per the NEC(ANSI/NFPA 70)Article 336-26.If other than uncoated(no-plated),601 or 75°C(140'or 167°C)insulation,copper wire(solid wire for 10 AWG or smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the NEC(ANSI/NFPA 70). $ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. •*Time-Delay fuse. FLA -Full Load Amps LRA -Locked Rotor Amps MCA -Minimum Circuit Amps RLA -Rated Load Amps NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. A-WEIGHTED SOUND LEVEL (dBA) STANDARD TYPICAL OCTAVE BAND SPECTRUM(without tone adjustment) UNIT SIZE-SERIES RATING 125 250 500 1000 2000 4000 8000 018-A 74 50.0 61.5 64.5 66.5 64.0 61.0 54.5 024-A 74 55.5 63.5 67.0 70.0 66.0 63.5 57.0 030-A 74 52.5 63.0 68.5 70.0 66.5 62.5 56.5 036-A 74 57.0 65.0 67.5 69.5 67.5 65.0 60.0 042-A 74 55.0 64.0 68.0 68.5 64.5 60.0 54.0 048-A 74 52.5 62.5 65.5 69.0 63.5 60.5 56.0 060-A 74 54.0 59.0 65.5 67.5 63.5 1 60.0 55.5 CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING(°F) 018-A 8 024-A 13 030-A 16 036-A 16 042-A 10 048-A 17 060-A 11 7 Z xxro co W =o Nd o ^ 0 1 Y J s 7 a LL G m m Lo e ' � O �o J F o 0 o x , x K 09 E�9ti aP 09-c-Mi90Z ui O O O O O O O9i-0EZ d • _ W K Qom Ws mu osi�ez•eoz a cn z � � w A s i COMBINATION RATINGS UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.RTUH SUPPLIED STANDARD EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING TDRt *CAP**1814A** 17,500 TXV 13.00 11.00 CAP**1814A** 17,200 TDR&TXV 14.50 11.70 315(A,J)AV036070 CAP**2414A** 17,700 TXV 13.00 11.00 CAP**2414A** 17,500 TDR&TXV 14.50 11.70 315(A,J)AV036070 CAP**2417A** 17.700 TXV 13.00 11.00 CAP**2417A** 17,500 TDR&TXV 14.50 11.70 355AAV042060 CAP**2417A** 17,600 TDR&TXV 14.50 11.70 315(A,J)AV048090 CNPV*1814A** 17,400 TXV 13.00 11.00 CNPV*1814A** 17.200 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNPV*2414A** 17,500 TXV 13.00 11.00 CNPV*2414A** 17,300 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNPV*2417A** 17,500 TXV 13.00 11.00 CNPV*2417A** 17,300 TDR&TXV 14.50 11.70 355AAV042060 CNPV*2417A** 17,400 TDR&TXV 14.50 11.70 315(A,J)AV048090 018-A(N) CNPH*2417A** 17,500 TXV 13.00 11.00 CNPH*2417A** 17.300 TDR&TXV 14.50 11.70 355AAV042040 CNPH*2417A** 17,300 TDR&TXV 14.50 11.70 355AAV042060 CNPH*2417A** 17,400 TDR&TXV 14.50 11.70 355AAV042080 CNPH*2417A** 17,300 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNPH*2417A** 17,400 TDR&TXV 14.50 11.70 315(A,J)AV048090 CNPF*2418A** i7,500 TXV 13.00 11.00 CSPH*2412A** 17,000 TXV 13.00 11.00 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 355AAV042040 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 355AAV042060 C8PH*2412A** 16,700 TDR&TXV 14.50 11.70 355AAV042080 CSPH*2412A** 16,600 TDR&TXV 14.50 11.70 315(A,J)AV036070 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 315(A,J)AV048090 FY4AN-F018 17,400 TDR&TXV 13.00 11.00 FY4ANF024 17,500 TDR&TXV 13.00 11.00 FX4CNF018 17,600 TDR&TXV 14.50 11.70 FX4CNF024 17,900 TDR&TXV 14.50 11.70 FE4ANF002 17,800 TDR&TXV 15.00 12.00 FFlENP018 17,400 TDR&TXV 13.00 11.00 FFIENP024 17,600 TDR&TXV 13.20 11.00 FV4BNF002 17,800 TDR&TXV 15.00 12.00 *CAP**2414A** 23,000 TXV 13.00 11 CAP**2414A** 22,600 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAP**2417A** 22,800 TXV 13.00 11,00 CAP**2417A** 22,600 TDR&TXV 14.00 11.50 355AAV042060 CAP**2417A** 22.600 TDR&TXV 14.50 11.70 315(A,J)AV048090 CAP**3014A** 23,000 TXV 13.00 11.00 CAP**3014A** 22.800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAP**3017A** 23,000 TXV 13.00 11.00 CAP**3017A** 22.800 TDR&TXV 14.50 11.70 355AAV042060 CAP**3017A** 22,800 TDR&TXV 14.50 11.70 315(A,J)AV048090 024-A(N) CNPV*2414A** 22,600 TXV 13.00 11.00 CNPV*2414A** 22,400 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNPV*2417A** 22,600 TXV 13.00 11.00 CNPV*2417A** 22,400 TDR&TXV 14.00 11.50 355AAV042060 CNPV*2417A** 22,400 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNPV*3014A** 22,800 TXV 13.00 11.00 CNPV*3014A** 22.600 TDR&TXV 14.00 11.15 315(A,J)AV036070 CNPV*3017A** 22,800 TXV 13.00 11.00 CNPV*3017A** 22,600 TDR&TXV 14.50 11.70 355AAV042060 CNPV*3017A** 22,600 TDR&TXV 14.50 11.70 315(A,J)AV048090 ee notes on pg.13 9 COMBINATION RATINGS CONTINUED UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.BTUH SUPPLIED STANDARD TDRt EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING CNPH*2417A** 22.600 TXV 13.00 11.00 CNPH*2417A** 22,400 TDR&TXV 14.00 1 11.50 1 355AAV042040 CNPH*2417A** 22,400 TDR&TXV 14.00 1 11.50 315(A,J)AV036070 CNPH*3017A** 22,800 TXV 13.00 11.00 CNPH*3017A** 22,600 TDR&TXV 14.50 11.70 355AAV042040 CNPH*3017A** 22,600 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNPF*2418A** 22,600 TXV 13.00 11.00 CSPH*2412A** 22,000 TXV 13.00 11.00 CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 355AAV042040 CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 355AAV042060 CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CSPH*2412A** 21,800 TDR&TXV 14.50 11.70 315(A,J)AV048090 CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 315(A,J)AV060110 CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 315(A,J)AV066135 CSPH*3012A** 22,000 TXV 13.00 11.00 024-A(N) CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 355AAV042040 CSPH*3012A** 21.800 TDR&TXV 14.50 11.70 355AAV042060 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 355AAV042080 CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 355AAV060080 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 355AAV060100 CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 355AAV060120 CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 315(A,J)AV036070 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 315(A,J)AV060110 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 315 A,J AV066135 CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 315(A,J)AV066155 FY4ANF024 22,600 TDR&TXV 13.00 11.00 FY4ANF030 22,800 TDR&TXV 13.20 11.00 FX4CNF024 23,000 TDR&TXV 14.00 11.50 FX4CNF030 23,200 TDR&TXV 14.00 11.50 FE4ANF002 23,000 TDR&TXV 14.50 11.70 FE4ANF003 23,000 TDR&TXV 14.50 11.70 FFlENP024 22,600 TDR&TXV 13.00 11.00 FFIENP030 22,600 TDR&TXV 13.00 11.00 FV4BNF002 23,000 TDR&TXV 14.50 11.70 FV4BNF003 23,000 TDR&TXV 15.00 12.00 *CAP**3014A** 28,000 TXV 13.00 11 CAP**3014A** 27,600 TDR&TXV 13.50 11.20 315(A,J)AV036070 CAP**3017A** 28,000 TXV 13.00 11.00 CAP**3017A** 27,600 TDR&TXV 14.00 11.50 355AAV042060 CAP**3017A** 27,600 TDR&TXV 14.00 11.50 315(A,J)AV048090 030-A(N,P) CAP**3614A** 28,000 TXV 13.00 11.00 CAP**3614A** 27,600 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAP**3617A** 28,000 TXV 13.00 11.00 CAP**3617A** 27.600 TDR&TXV 14.00 11.50 355AAV042060 CAP**3617A** 27,800 TDR&TXV 14.00 11.50 315(A,J)AV048090 CAP**3621A** 28.000 TXV 13.00 11.00 See notes on pg.13 10 COMBINATION RATINGS CONTINUED UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.BTUH SUPPLIED STANDARD EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING TDRY CAP**3621A** 27.800 TDR&TXV 14.00 11.50 355AAV042080 CAP**3621A** 27,800 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNPV*3014A** 27,800 TXV 13.00 11.00 CNPV*3014A** 27,400 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNPV*3017A** 27,800 TXV 13.00 11.00 CNPV*3017A** 27,400 TDR&TXV 14.00 11.50 355AAV042060 CNPV*3017A** 27,400 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNPV*3617A** 27,800 TXV 13.00 11.00 CNPV*3617A** 27,400 TDR&TXV 14.00 11.50 355AAV042060 CNPV*3617A** 27,400 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNPV*3621A** 27,800 TXV 13.00 11.00 CNPV*3621A** 27,400 TDR&TXV 14.00 11.50 355AAV042080 CNPV*3621A** 27,600 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNPH*3017A** 27,800 TXV 13.00 11.00 CNPH*3017A** 27,400 TDR&TXV 13.50 11.20 355AAV042040 CNPH*3017A** 27,400 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNPH*3617A** 27,800 TXV 13.00 11.00 030-A(N,P) CNPH*3617A** 27,400 TDR&TXV 13.50 11.20 355AAV042040 CNPH*3617A** 27,400 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNPF*3618A** 27,800 TXV 13.00 11.00 CSPH*3012A** 27,000 TXV 13.00 11.00 CSPH*3012A** 26,800 TDR&TXV 13.50 11.20 355AAV042040 CSPH*3012A** 26,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CSPH*3612A** 27,400 TXV 13,20 11.00 CSPH*3612A** 27,200 TDR&TXV 14.00 11.50 355AAV042040 CSPH*3612A** 27,200 TDR&TXV 14.00 11.50 315(A,J)AV036070 FY4ANF030 27.600 TDR&TXV 13.00 11.00 FY4ANF036 27,800 TDR&TXV 13.00 11.00 FX4CNF030 28,000 TDR&TXV 13.50 11.20 FX4CN B, 036 28,200 TDR&TXV 14.00 11.50 FE4ANF002 27,800 TDR&TXV 14.00 11.50 FE4ANF003 28,000 TDR&TXV 14.50 11.70 FE4ANF005 28,800 TDR&TXV 15.00 12.00 FF1 ENP030 27,400 TDR&TXV 13.00 11.00 FFIENP036 28,000 TDA&TXV 13.20 11.00 FV48NF002 27,800 TDR&TXV 14.00 11.50 FV4BNF003 28,000 TDR&TXV 14.50 11.70 FV4BNFo05 28,800 TDA&TXV 15.00 12.00 *CAP**3617A** 34.000 TXV 13.00 11.00 CAP**3614A** 33,000 TXV 13.00 11.00 CAP**3614A** 33,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CAP**3617A** 33,600 TDR&TXV 14.00 11.50 355AAV042060 CAP**3617A** 33,600 TDR&TXV 14.00 11.50 315(A,J)AV048090 CAP**3621A** 34,000 TXV 13.00 11.00 CAP**3621A** 33,600 TDR&TXV 13.50 11.20 355AAV042080 CAP**3621A** 33,800 TDR&TXV 14.00 11.50 315(A,J)AV060110 036-A CAP**4221A** 34,000 TXV 13.00 11.00 (N,P,E) CAP**4221A** 33,800 TDR&TXV 14.00 11.50 355AAV042080 CAP**4221A** 34.000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CAP**4224A** 34,000 TXV 13.00 11.00 CAP**4224A** 33.800 TDR&TXV 14.00 11.50 355AAV042040 CAP**4224A** 34,000 TDR&TXV 14.50 11.70 315(A,J)AV066135 NPV*3617A** 33,800 TXV 13.00 11.00 CNPV*3617A** 33,200 TDR&TXV 13.50 11.20 355AAV042060 CNPV*3617 ** 33,400 TDA TXV 14.00 11.50 315(A,J)AV048090 CNPV*3621A** 33,800 TXV 13.00 11.00 CNPV*3621A** 33,600 TDR&TXV 13.00 11.00 355AAV042080 See notes on pg.13 11 COMBINATION RATINGS CONTINUED UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.eTUH SUPPLIED STANDARD EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING TOW CNPV*3621A** 33,800 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNPV*4221A** 34,000 TXV 13.00 11.00 CNPV*4221A** 34,200 TDR&TXV 14.00 11.50 355AAV042080 CNPV*4221A** 34,600 TDR&TXV 14.50 11.70 315(A,J)AV060110 CNPH*3617A** 33,800 TXV 13.00 11.00 CNPH*3617A** 33,200 TDR&TXV 13.50 11.20 355AAV042040 CNPH*3617A** 33,200 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNPH*4221A** 34,000 TXV 13.00 11.00 CNPH*4221A** 34,200 TDR&TXV 14.00 11.50 355AAV042040 CNPH*4221A** 34,400 TDR&TXV 14.00 11.50 355AAV042060 CNPH*4221A** 34,200 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNPF*3618A** 33,800 TXV 13.00 11.00 CSPH*3612A** 33,600 TXV 13.00 11.00 036-A(N,P,E) CSPH*3612A** 33,200 TDR&TXV 14.00 11.50 355AAV042040 CSPH*3612A** 33,200 TDR&TXV 14.00 11.50 315(A,J)AV036070 CSPH*4212A** 33,800 TXV 13.20 11.20 CSPH*4212A** 33,800 TDR&TXV 13.50 11.20 355AAV042040 CSPH*4212A** 34,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 FY4ANF036 33,800 TDR&TXV 13.00 11.00 FY4ANF042 34,400 TDR&TXV 13.00 11.00 FX4CN(B,F)036 34,400 TDR&TXV 14.00 11.50 FX4CN(B,F)042 34,800 TDR&TXV 14.00 11.50 FE4ANF002 33,600 TDR&TXV 14.00 11.50 FE4ANF003 34.000 TDR&TXV 14.50 11.70 FE4ANF005 35,000 TDR&TXV 15.00 12.00 FE4ANb006 35,400 TDR&TXV 15.00 12.00 FFIENP036 33,800 TDR&TXV 13.00 11.00 FV4BNF002 33,600 TDR&TXV 14,00 11.50 FV4SNF003 34,000 TDR&TXV 14.50 11.70 FV4BNF005 35.000 TDR&TXV 15.00 12.00 FV4BNB006 35.400 TDR&TXV 15.00 12.00 *CAP**4221A** 41,000 TXV 13.00 11.00 CAP**4221A** 40,000 TDR&TXV 13.50 1120 355AAV042080 CAP**4221A** 40,500 TDR TXV 13.50 11.20 315(A,J)AV060110 AP**4224A** 41,000 TV 13.00 11.00 CAP**4224A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CAP**4224A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CAP**4817A** 40,000 TXV 13.20 11.00 CAP**4817A** 40,000 TDR&TXV 14.00 11.50 355AAV042060 CAP**4817A** 40,000 TDR&TXV 14.00 11.50 315(A,J)AV048030 CAP**4821A** 41,500 TXV 13.20 11.00 CAP**4821A** 40,500 TDR&TXV 13.50 1120 355AAV042080 CAP**4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 AP**4824A** 41,500 TXV 13.20 11.00 042-A(N,P,E) CAP**4824A** 41,000 TDR&TXV 13.50 11.20 355AAV042040 CAP**4824A** 41,000 TDR&TXV 14.50 11.70 315(A,J)AV066135 CNPV*4221A** 41,000 TXV 13.00 11.00 CNPV*4221A** 40,000 TDR&TXV 13.50 11.20 355AAV042080 CNPV*4221A** 40,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNPV*4821A** 40,500 TXV 13.20 11.00 CNPV*4821A** 40,500 TDR&TXV 13.50 11.20 355AAV042080 CNPV*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 NPV*4824A** 41,500 TXV 13.20 11.00 CNPV*4824A** 41,000 TDR&TXV 13.50 11.20 365AAV042040 CNPV*4824A** 40,500 TDR&TXV 14.50 11.70 315 A, AV066135 CNPH*4221A** 41,000 TXV 13.00 11.00 CNPH*4221A^* 40,000 TDR&TXV 13.50 11.20 355AAV042040 CNPH*4221A** 40.500 TDR&TXV 13.50 11.20 315(A,J)AV036070 See notes on pg.13 12 t • 1 COMBINATION RATINGS CONTINUED UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.BTUH SUPPLIED STANDARD EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING TDRt CNPH*4821A** 41,500 TXV 13.20 11.00 CNPH*4821A** 40,500 TDR&TXV 13.50 11.20 355AAV042040 CNPH*4821A** 41,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNPF*4818A** 41,500 TXV 13.20 11.00 CSPH*4212A** 40,500 TXV 13.20 11.00 CSPH*4212A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CSPH*4212A** 40.000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CSPH*4812A** 41,000 TXV 13.20 11.00 042-A(N,P,E) CSPH*4812A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CSPH*4812A** 40,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 FY4ANF042 41,000 TDR&TXV 13.00 11.00 FY4ANF048 42,000 TDR&TXV 13.20 11.00 FX4CN(B,F)042 41,500 TDR&TXV 13.50 11.20 FX4CN(B,F)048 42,500 TDR&TXV 14.00 11.50 FE4ANF003 40,500 TDR&TXV 14.00 11.50 FE4ANF005 42,000 TDR&TXV 14.50 11.70 FE4ANB006 42,500 TDR&TXV 15.00 12.00 FV4BNF003 40,500 TDR&TXV 14.00 11.50 FV4BNF005 41,500 TDR&TXV 14.50 11.70 FV4BNB006 42,500 TDR&TXV 15.00 12.00 *CAP**4821A** 46,000 TXV 13.00 11.00 CAP**4817A** 45,500 TXV 113.00 11.00 CAP**4817A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV048090 CAP**4821A** 45,000 TDR&TXV 13.20 11.00 355AAV060080 CAP**4821A** 45,000 TDR&TXV 13.65 11.40 355AAV060100 CAP**4821A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV060110 CAP**4824A** 46,000 TXV 13.00 11.00 CAP**4824A** 45,000 TDR&TXV 13.50 11.20 355AAV060120 CAP**4824A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV066135 CAP**6021A** 47,000 TXV 13.20 11.00 CAP**6021A** 46,000 TDR&TXV 13.50 11.20 355AAV060080 CAP**6021A** 47,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CAP**6024A** 47,000 TXV 13.20 11.00 6AP**6024A** 46,000 TDR&TXV 14.00 11.50 355AAV060120 CAP**6024A** 46,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNPV*4221A** 44,500 TXV 13.00 10.95 CNPV*4221A** 44,500 TDR&TXV 13.20 11.00 355AAV060080 048-A(N, E) CNPV*4221A** 44,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 P, NPV*4821A** 46,000 TXV 13.00 11.00 CNPV*4821A** 45,000 TDR&TXV 13.20 11.00 355AAV0600BO CNPV*4821A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNPV*4824A** 46,000 TXV 13.00 11.00 CNPV*4824A** 45,500 TDR&TXV 13.50 11.20 355AAV060120 CNPV*4824A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV066135 CNPV*6024A** 47,000 TXV 13.20 11.00 IVPV*6024A** 46.000 TDR&TXV 13.50 11.20 355AAV060120 CNPV*6024A** 46.000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNPH*4821A** 46,000 TXV 13.00 11.00 CNPH*4821A** 45,000 TDR&TXV 13.20 11.00 355AAV060080 CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 355AAV060100 CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 NPH*4821A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNPH*6024A** 47,000 TXV 13.20 ii.00 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 355AAV060080 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 355AAV060100 CNPH*6024A** 46,000 TDR TXV 13.50 11.20 315(A,J)AV048090 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNPF*4818A** 45,000 TXv 13.00 11.00 See notes on pg.13 13 M1 COMBINATION RATINuS CONTINUED UNIT SIZE- FACTORY SEER SERIES INDOOR MODEL TOTAL CAP.BTUH SUPPLIED STANDARD EER FURNACE MODEL (VOLTAGE) ENHANCEMENT RATING TDRt CSPH*4812A** 45,500 TXV 13.00 11.00 CSPH*4812A** 44,500 TDR&TXV 13.20 11.00 355AAV060080 CSPH*4812A** 44.500 TDR&TXV 13.50 11.20 315(A,J)AV048090 CSPH*6012A** 46,000 TXV 13.20 11.00 CSPH*6012A** 45,000 TDR&TXV 13.50 11.20 355AAV060080 CSPH*6012A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 048-A(N,P,E) FX4CN(B,F)048 47,000 TDR&TXV 13.50 11.20 FX4CN(B,F)060 47,500 TDR&TXV 14.00 11.50 FE4ANF005 46,500 TDR&TXV 14.00 11.50 FE4ANB006 47,000 TDR&TXV 14.50 11.70 FV4BNF005 46,500 TDR&TXV 14.00 11.50 FV4BNB006 47,000 TDR&TXV 14.50 11.70 FY4ANF048 46,000 TDR&TXV 13.00 11.00 FY4ANB060 46,500 TDR&TXV 13.20 11.00 *CAP**6024A** 57,500 TXV 13.00 11.00 CAP**6021A** 56,500 TXV 13.00 11.00 CAP**6021A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV060110 CAP**6024A** 56,500 TDR&TXV 13.20 11.00 315(A,J)AV066135 CAP**6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155 CNPV*6024A** 57,000 TXV 13.00 11.00 CNPV*6024A** 56,000 TDR&TXV 13.50 11.00 315(A,J)AV066135 CNPV*6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155 060-A(N,P,E) CNPH*6024A** 56,000 TXV 13.00 11.00 CNPH*6024A** 56,000 TDR&TXV 13.50 11.20 315(A,J)AV066135 CNPH*6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155 CSPH*6012A** 56,500 TXV 13.00 11.00 CSPH*6012A** 55,500 TDR&TXV 13.20 11.00 315(A,J)AV060110 CSPH*6012A** 55,500 TDR&TXV 13.50 11.20 315(A,J)AV066135 CSPH*6012A** 55,500 TDR&TXV 13.50 11.20 315(A,J)AV066155 FX4CN(B,F)060 58.000 TDR&TXV 13.20 11.00 FE4ANB006 57,000 TDR&TXV 13.50 11.20 FV4BNB006 57,000 TDR&TXV 13.50 11.20 FY4ANB060 56,500 TDR&TXV 13.00 11.00 'Tested combination t In most cases,only 1 method should be used to achieve TDR function.Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.Most Bryant furnaces are equipped with TDR. NOTES: 1.Ratings are net values reflecting the effects of circulating fan motor heat.Supplemental electric heat is not included. 2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners.Ratings for other combinations are determined under DOE computer simulation procedures. 3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4.Do not apply with capillary tube coils as performance and reliability are significantly affected. EER-Energy Efficiency Ratio SEER-Seasonal Energy Efficiency Ratio TDR-Time-Delay Relay TXV-Thermostatic Expansion Valve 14 i DETAILED COOLING t:APACITIEStt EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES dog F AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity MBtuht Total MBtuht Total MBtuht Total MBtuht Total MBtuht Total MBtuht Total CFM EWB System System System System System System Total Sens KW** Total Sens# KW** Total Sens# KW** Total Sens# KW** Total 'Sens# KW** Total Sens# KW** 123ANADIS-A Outdoor Section With CAP**1814A**Indoor Section 72 20.46 10.76 1.21 19.55 10.41 1.36 18.59 10.05 1.53 17.62 9.69 1.71 16.57 9.30 1.91 15.40 8.88 2.13 525 67 18.79 13.26 1.22 17.95 12.90 1.37 17.05 12.52 1.53 16.12 12.14 172 15.13 11.74 1.92 14.03 11.30 2.13 62 17.27 15.73 1.22 16.49 15.36 1.37 15.66 14.97 1.54 14.83 14.55 1.72 14.00 14.00 1.92 13.15 1315 2.13 57 16.78 16.78 1.23 16.15 16.15 1.37 15.46 15.48 1.54 14.77 14.77 1.72 14.00 14.00 1.92 13.15 13.15 2.13 72 2079. 11.28 1.24 19.83 10.92 1.39 18.83 10,55 1.56 17.83 10.19 1.74 16.76 9.60 1.94 15.55 9.37 2.16 600 67 19.11 14.10 1.25 18.23 13.73 1.40 17.30 13.36 1.56 16.35 12.97 1.74 15.33 12.57 1.94 14,20 12.12 2.16 6 117.66 16.88 1 1.25 16.87 116.49 1 1.40 16.06 11&06 1 1.56 15.32 1 15.32 1.75 114.51 114.51 1.94 113.61 13.61 1 2.16 57 17.46 17.46 1.25 16.79 16.79 1.40 16.07 16,07 1.56 15.32 15.32 1.75 14.51 14.51 1.94 13.61 13.61 2.16 72 21.03 11.77 1.27 20,02 11.40 1.42 18.99 11.03 1.58 17.97 10.67 1.77 16.88 10.28 1.97 15.65 9.85 2.18 675 67 19.33 14.90 1.27 18.43 14454 1.42 17.48 14.15 1.59 16.51 13.77 1.77 15.48 13.35 1.97 14.33 12.89 219 62 18.01 17.91 1.28 17.30 17.30 1.43 16.54 16.54 1.59 15.76 15.76 1.77 14.92 14.92 1.97 13.97 13.97 2.19 57 18.01 18.01 1,28 17.30 17.30 1.43 16.55 16.55 1.59 15.76 15.76 1.77 14,92 14.92 1.97 13.97 13.97 2.19 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Model Capacity Power Furnace Model Cooling Indoor Model Capacity Power Furnace Model *CAP**1614A** 1.00 1.00 CAP**1814A** 0.98 0.92 315(A,J)AV036070 CAP**2414A** 1.01 1.01 CAP**2414A** 1.00 0.94 315(A,J)AV036070 CAP**2417A** 1.01 1.01 CNPH*2417A** 0.99 0.93 315(A,J)AV036070 CNPF*2418A** 1.00 1.00 CNPV*1814A** 0.98 0.92 315(A,J)AV036070 CNPH*2417A** 1.00 1.00 CNPV*2414A** 0.99 0.93 315(A,J)AV036070 CNPV*1814A** 0.99 0.99 CSPH*2412A** 0.95 0.89 315(A,J)AV036070 CNPV*2414A** 1_00 1x0 CAP**2417A** 1.01 0.95 315(A,J)AV048090 CNPV*2417A** 1.00 1.00 CNPH*2417A** 0.99 0.93 315(A,J)AV048090 CSPH*2412A** 0,97 0,97 CNPV*2417A** 0.99 0.93 315(A,J)AV048090 FE4ANF002 1.02 0.93 CSPH*2412A** 0.95 0.90 315(A,J)AV048090 FFiENP018 0.99 0.99 CNPH*2417A** 0.99 0.93 355AAV042040 FFI ENP024 1.01 1.01 CSPH*2412A** 0.95 0.90 355AAV042040 FV4BNF002 1-02 0.93 CAP**2417A** 1.00 0.94 355AAV042060 FX4CNF018 I.01 0.95 CNPH*2417A** 0.99 0.93 355AAV042060 FX4CNF024 1.02 0.96 CNPV*2417A** 0.99 0.93 355AAV042060 FY4ANF018 0.99 0.99 CSPH*2412A** 0,95 0.90 355AAV042060 FY4ANF024 1.00 1.00 CNPH*2417A** 0,99 0.93 355AAV042080 CSPH*2412A** 0.95 0.90 355AAV042080 See notes on pg.20 15 7i DETAILED COOLING CAPACITIEStt (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES deg F AIR 75 85 1 95 1 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuht MBtuht MBtuht MBtuht MBtuht MBtuht CFM EWB System System System System System System Total Sens KW** Total Sens KW** Total Sens# KW** Total Sens KW** Total Sens KW** Total Sens KW** 123ANA024"A Outdoor Section With CAP**2414A**Indoor Section # # # # # 72 27.11 14.29 1.61 25.97 13.86 1.81 2475 13.40 2.03 23.47 12,92 2.2B 22.09 1241 2.55 20.55 11.85 2.84 700 67 24.89 17.62 1461 23.81 17.16 1.81 22.66 16,68 2.03 21.45 16.19 2.28 20.15 15.66 2.55 18.73 15.09 2.85 62 22.86 20.91 1.61 21.86 20.44 1.81 20.81 19.93 2.04 19.72 19.39 2.2B 18.65 1 B.65 2.56 17.57 17.57 2.86 57 22.24 22-24 1.61 21.43 21.43 1.82 20,56 20,56 2.04 19.64 19.64 2.28 18.65 16.65 256 17.57 17.57 2.86 72 27.54 14.98 1.64 26.35 14,54 1.84 25-08 14.08 2.06 23.76 13.60 2.31 22.34 13.09 2.58 20.75 12.52 2.88 800 67 25.31 18.74 1,64 24.19 18.29 1.85 23.00 17.81 2.07 21.75 17.31 2.31 20.42 16.77 2.59 18.96 16.19 286 62 23.37 22.46 1.65 22.36 21.95 1.85 21.35 21.35 2.07 20.38 20.38 2.32 19.33 19.33 2.59 18.18 18.18 2.89 57 23.14 23.14 1.65 22.28 22.28 1.85 21.36 21.36 2,07 20.38 20.38 2,32 19.33 19.33 2.59 18.18 18.18 2.89 72 27.83 15.64 1.68 26.61 15.19 1.88 25.31 14.72 2.10 23.96 14.25 2.34 22.50 13.73 2.61 20.87 13.16 2.91 900 67 25.61 19.B3 1.68 24.46 �2 ,6 37 1.88 23.25 18,88 2.10 21.97 18.37 2.35 20.61 17.83 2.62 19.12 17.24 2.92 62 23.85 23.85 1.68 22.96 1.88 22.00 22.00 2.15 20,98 20.98 2.35 19.87 19.87 262 16.66 18.66 2.92 57 23.87 23.07 1.68 22.97 97 1.80 22.00 22,00 2,10 20.98 20.90 2.35 19.87 19.87 2.62 10.66 18.66 2.92 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Capacity Power Furnace Model Cooling Indoor Capacity Power Furnace Model Model Model *CAP**2414A** 1.00 1.00 CAP**2414A** 0.98 0.94 315(A,J)AV036070 CAP**2417A** 0.99 0.99 CAP**3014A** 0.99 0.95 315(A,J)AV036070 CAP**3014A** 1.00 1.00 CNPH*2417A** 0.97 0.93 315(A,J)AV036070 CAP**3017A** 1.00 1.00 CNPH*3017A** 0.98 0.92 315(A,J)AV036070 CNPF*2418A** 0.98 0.98 CNPV*2414A** 0,97 0.93 315(A,J)AV036070 CNPH*2417A** 0.98 0.98 CNPV*3014A** 0.98 0.97 315(A,J)AV036070 CNPH*3017A** 0.99 0.99 CSPH*2412A** 0.95 0.91 315(A,J)AV036070 CNPV*2414A** 0.98 0.98 CSPH*3012A** 0.95 0.89 315(A,J)AV036070 CNPV*2417A** 0.98 0.98 CAP**2417A** 0.98 0.92 315 A,J AV048090 CNPV*3014A** 0.99 0.99 CAP**3017A** 0.99 0.93 315&,I AV048090 CNPV*3017A** 0.99 0.99 CNPV*2417A** 0.97 0.93 315(A,J)AV048090 CSPH*2412A** 0.96 0.96 CNPV*3017A** 0.98 1 0.92 315(A,J)AV048090 CSPH*3012A** 0.96 0.96 CSPH*2412A** 0.95 0.89 315(A,J)AV048090 FE4ANF002 1.00 0.94 CSPH*3012A** 0.96 0.90 315(A,J)AV048090 FE4ANF003 1.00 0.94 CSPH*2412A** 0.95 0.91 315(A,J)AV060110 FFlENP024 0.98 0.98 CSPH*3012A** 0.96 0.90 315(A,J)AV060110 FFlENP030 0.98 0.98 CSPH*2412A** 0.95 0.91 315(A,J)AV066135 FV4BNF002 1.00 0.94 CSPH*3012A** 0.96 0.90 315(A,J)AV066135 FV4BNF003 1.00 0.92 CSPH*3012A** 0.96 0.90 1 315(A,J)AV066155 FX4CNF024 1.00 0.96 CNPH*2417A** 0.97 0.93 355AAV042040 FX4CNF030 1.01 0.96 CNPH*3017A** 0.98 0.92 355AAV042040 FY4ANF024 0.98 0.98 CSPH*2412A** 0.95 0.91 355AAV042040 FY4ANF030 0.99 0.99 CSPH*3012A** 0.96 0.90 355AAV042040 CAP**2417A** 0.98 0.94 355AAV042060 CAP**3017A** 0.99 0.93 355AAV042060 CNPV*2417A** 0.97 0.93 355AAV042060 CNPV*3017A** 0.98 0.92 355AAV042060 CSPH*2412A** 0.95 0.91 355AAV042060 CSPH*3012A** 0.95 0.89 355AAV042060 CSPH*3012A** 0.96 0.90 355AAV042080 CSPH*3012A** 0.95 0.89 355AAV060080 0.9 CSPH*3012A** 6 0.90 355AAV060100 CSPH*3012A** 0.95 0.89 355AAV060120 See notes on pg.20 16 DETAILED COOLING tt_.APACITIES" (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES deg F AIR 75 BS 1 95 1 105 1 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuht MBtuht MBtuht MBtuht MBtuht MBtuht CFM EWB System System System System System System Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** 030 Outdoor 72 33.13 17.60 2.01 31.70 1706 2,23 30.20 1649 247 2859 15.90 2.75 26.81 15.27 3.06 25.01 -i 3.38 875 67 30.12 21.64 2.01 28.78 21.09 2.23 27.37 20.50 2.48 25.87 19.89 2.76 24.27 19.25 1 3.07 122,59 18.58 3.42 62 27.50 25.68 2.01 26.29 25.09 2.23 25.03 24.47 2.48 23.75 23.75 2.77 22.56 22.56 3.08 21.27 21.27 3.43 57 26.93 26.93 2.01 25,94 25.94 2.24 24.89 24.89 2.48 23.76 23.76 2.77 22.56 22.56 3.08 21.27 21.27 3.43 72 33.69 18.46 2.05 32.21 17.92 2.27 30.64 17.34 2.52 28,98 16.74 2.80 27.20 16.10 3.11 25.32 15.44 3.45 1000 67 30.64 23.04 2.05 29.26 22.48 2.27 27.80 21.89 2.52 26.25 21.27 2.80 24.61 20.61 3.12 22.87 19.92 3.46 62 28.16 27.55 1 2.06 26,95 126.95 1 2.28 25.86 25.86 2.53 1 24.67 124.67 2.81 23.39 23.39 3.12 22.02 22.02 3.47 57 28.03 28.03 2.06 26.98 26.98 2.28 25.86 25.86 2.53 24.67 24.67 2.81 23.39 23.39 3.12 22.02 22.02 3.47 72 34.09 19.27 2.10 32.57 18,72 2.32 30.96 1 B.14 2.56 29.26 17.54 2.84 27.43 16.8925.50 16.22 3.49 1125 67 31.03 24.36 2.10 29,61 23-80 2.32 28.12 23.20 2.57 26.54 22.57 2.85 24.86 21.9023.10 21.19 3.50 62 28.94 28.94 2.10 27.83 27.83 2.32 26.66 26.66 2.57 25.40 25.40 2.85 24.06 24.06 3.16 2261 22,61 3.48 57 26.94 28.94 2.10 27,83 27.83 2.32 26.66 26.66 2.57 25.41 25.41 2.85 24.06 24,06 3.16 22.62 22.62 3.51 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Capacity Power Furnace Model Cooling Indoor Capacity Power Furnace Model Model Model *CAP**3014A** 1.00 1.00 CAP**3014A** 0.99 0.97 315(A,J)AV036070 CAP**3017A** 1.00 1.00 CAP**3614A** 0.99 0.94 315(A,J)AV036070 CAP**3614A** 1.00 1.00 CNPH*3017A** 0.98 0.94 315(A,J)AV036070 CAP**3617A** 1.00 1.00 CNPH*3617A** 0.98 0.94 315(A,J)AV036070 CAP**3621A** 1.00 1.00 CNPV*3014A** 0.98 0.96 315(A,J)AV036070 CNPF*3618A** 0.99 0.99 CSPH*3012A** 0.96 0.92 315(A,J)AV036070 CNPH*3017A** 0.99 0.99 CSPH*3612A** 0.97 0.93 315(A,J)AV036070 CNPH*3617A** 0.99 0.99 CAP**3017A** 0.99 0.94 315(A,J)AV048090 CNPV*3014A** 0.99 0.99 CAP**3617A** 0.99 0.95 315(A,J)AV048090 CNPV*3017A** 0.99 0.99 CNPV*3017A** 0.98 0.94 315(A,J)AV048090 CNPV*3617A** 0.99 0.99 CNPV*3617A** 0.98 0.94 315(A,J)AV048090 CNPV*3621A** 0.99 0,99 CAP**3621A** 0.99 0.95 315 A,J AV060110 CSPH*3012A** 0.96 0.96 CNPV*3621A** 0.99 0.94 315(A,J)AV060110 CSPH*3612A** 0.98 0.98 CNPH*3017A** 0.98 0.96 355AAV042040 FE4ANF002 0.99 0.95 CNPH*3617A** 0.98 0.96 355AAV042040 FE4ANF003 1.00 0.94 CSPH*3012A** 0.96 0.94 355AAV042040 FE4ANF005 1.03 0.94 CSPH*3612A** 0.97 0.93 355AAV042040 FF1 ENP030 0.98 0.98 CAP**3017A** 0.99 0.94 355AAV042060 FF1 ENP036 1.00 1.00 CAP**3617A** 0.99 0.94 355AAV042060 FV4BNF002 0.99 0.95 CNPV*3017A** 0.98 0.94 355AAV042060 FV4BNF003 1.00 0.94 CNPV*3617A** 0.98 0.94 355AAV042060 FV4BNF005 1.03 6.94 CAP**3621A** 0.99 0.95 355AAV042080 FX4CN(B,F)036 1.01 0.96 CNPV*3621A** 0.98 0.94 _ 355AAV042080 FX4CNF030 1.00 0.98 FY4ANF030 0.99 0.99 FY4ANF036 0.99 0.99 See dotes on pg.20 17 DETAILED COOLING kAPACITIEStt (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES deg F AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity MBtuht Total MBtuht Total MBtuht Total MBtuht Total MBtuht Total MBtuht Total CFM EWB System System System System System System Total Sens KW- Total Sens Ryy** Total Sens KVy** Total Sen KW** Total Sens KW** Total Sens KW** # # # s# # # 123ANA036-A Outdoor Section With CAP**3617A**indoor Section 72 40.12 21.34 2.4B 38.42 20.70 2.74 36.61 20.02 3.03 34.70 19.31 3.35 32.62 18.55 3.71 30.32 17.72 4.09 1050 67 36.62 26.34 2.47 35.03 25.67 2.73 33.34 24.97 3.02 31.55 24.24 3.34 29.62 23.47 3.70 27.50 22.62 4.09 62 33.54 31.31 2.46 32.11 30.61 2.72 30.61 29.86 3.01 29.06 29.06 3.34 27.62 27.62 3.70 25.99 25.99 4.09 57 32.88 3288 2.46 31.70 31.70 2.72 30.44 30.44 3.01 29.09 29.09 3.34 27.63 27.63 3.70 26.00 26.00 4.09 72 40.72 22.34 2.54 38.96 21,69 2.80 37,09 21.00 3.09 35.11 20.28 3.41 32.97 19.51 3.76 30.60 18.67 4.15 1200 67 37.19 27.96 2.53 35.54 27.28 2.79 33.80 26.58 3.08 31.96 25.85 3.40 29.98 25.06 3.76 27.81 24,20 4.15 62 34.30 33.50 2.52 32.84 32.84 2.78 31.55 31.55 3.07 30.12 30,12 3.40 28.56 28.56 3.75 26.83 26.83 4.14 57 34.15 34.15 1 2.52 32.89 32.89 2.78 31.55 31.55 3.07 30.12 30.12 3.40 28.56 28.56 3.75 26.83 26.83 4.14 72 41.16 23.27 2.60 39.34 22.61 2.86 37.42 21.92 3.14 35.40 21.20 3.47 33.21 20.42 3.62 30.78 19.57 4.21 1350 67 37.62 29.51 2.59 35.93 28.83 2.85 34.15 2B.12 3.14 32.27 27.38 3.46 30.25 26.57 3.61 28.05 25.67 4.20 62 35.18 35.18 2.58 33.86 33.86 2.84 32.45 32.45 3.13 30.95 30.95 3.46 29.31 29.31 3.81 27.50 27.50 4.20 57 35.19 35.19 2.58 33.86 33,86 2.84 32.46 32.46 3.13 30.95 30.95 3.46 29.31 29.31 3.81 27.50 2Z50 4.20 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Model Capacity Power Furnace Model Cooling Indoor Model Capacity Power Furnace Model *CAP**3617A** 1.00 1.00 CAP**3614A** 0.97 0.95 315(A,J)AV036070 CAP**3614A** 0.97 0.97 CNPH*3617A** 0.98 0.96 315(A,J)AV036070 CAP**3621A** 1.00 1.00 CNPH*4221A** 1.01 0.96 315(A,J)AV036070 CAP**4221A** 1.00 1.00 CSPH*3612A** 0.98 0.93 315(A,J)AV036070 CAP**4224A** 1.00 1.00 CSPH*4212A** 1.00 0.98 315(A,J)AV036070 CNPF*3618A** 0.99 0.99 1 CAP**3617A** 0.99 0.95 315(A,J)AV048090 CNPH*3617A** 0.99 0.99 CNPV*3617A** 0.98 0.94 315(A,J)AV048090 CNPH*4221A** 1.00 1.00 CAP**3621A** 0.99 0.95 315(A,J)AV060110 CNPV*3617A** 0.99 0.99 CAP**4221A** 1.00 0.96 315(A,J)AV060110 CNPV*3621A** 0.99 0.99 CNPV*3621A** 0.99 0.98 315(A,J)AV060110 CNPV*4221A** 1.00 1.00 CNPV*4221A** 1.02 0.96 315(A,J)AV060110 CSPH*3612A** 0.99 0.99 CAP**4224A** 1.00 1 0.94 315(A,J)AV066135 CSPH*4212A** 0.99 0.98 CAP**4224A** 0.99 0.95 355AAV042040 FE4ANB006 1.04 0.95 CNPH*3617A** 0.98 0.96 355AAV042040 FE4ANF002 0.99 0.95 CNPH*4221A** 1.01 0.96 355AAV042040 FE4ANF003 1.00 0.94 CSPH*3612A** 0.98 0.93 355AAV042040 FE4ANF005 1.03 0.94 CSPH*4212A** 0.99 0.98 355AAV042040 FFlENP036 0.99 0.99 CAP**3617A** 0.99 0.95 355AAV042060 FV4BNB006 1.04 0.95 CNPH*4221A** 1.01 0.97 355AAV042060 FV4BNF002 0.99 0.95 CNPV*3617A** 0.98 0.96 355AAV042060 FV4BNF003 1.00 0.94 CAP**3621A** 0.99 0.97 355AAV042080 FV4BNF005 1.03 0.94 CAP**4221A** 0.99 0.95 355AAV042080 FX4CN(B,F)036 1.01 0.97 CNPV*3621A** 0.99 0.99 355AAV042080 FX4CN(B,F)042 1.02 0.98 CNPV*4221A** 1.01 0.96 355AAV042680 FY4ANF036 0.99 0.99 FY4ANF042 1.01 1.01 See notes on pg.20 18 DETAILED COOLING C APACITIEStt (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES deg F AIR 75 85 95 105 115 125 Capacity Capacity Capacity hMB city Capacity Capacity Total Total Total Total Total Total MBtuht MBtuht MBtuht uht MBtuht MBtuhtSystem System System System System System Total Sens Kyy** Total Sens KW** Total Sens Kw** Sens KW** Total Sens Kyy** Total Sens KW** # # # # # # 123ANA0,12-A Outdoor Secuon With CAP"4221A*l Indoor Section 72 4&51 25.52 3.33 46.40 24,71 3.68 44.17 23.86 4.08 41.83 22.99 4,51 39.30 22.05 4.99 36.50 21.03 &51 1225 67 44.49 31.40 3.31 4253 30.57 3.66 40.46 29.71 4.06 38.30 28.81 4.50 35,96 27.87 4.98 33.41 2&84 5.51 62 40.85 37.25 3.29 39.08 36.40 3.65 37.24 35,50 4.04 35.33 34.54 4.48 33.39 33.39 4.97 31.44 31.44 5.50 57 39.76 39.76 3.29 38.32 38.32 3.64 36.79 36,79 4.04 35.17 35.17 4.48 33.41 33.41 4.97 31.45 31.45 5.50 72 49.22 26.65 3.40 47A2 25,82 3.76 44,72 24.97 4.15 42.30 24.08 4.59 39.69 23.14 5.07 36.79 22.10 5.59 1400 67 45.18 33.25 3.38 43.15 32,40 3.74 41.00 31.53 4.13 38.76 30.63 4.57 36.37 29.68 5.05 33.74 28,63 5.58 62 41.71 39.81 3.37 39.92 36,90 3.72 38.04 38.04 4,12 3&38 36.38 4.56 34,50 34.50 5.05 32.41 3241 5.58 57 41.28 41.28 3.37 39.74 39.74 3.72 38.11 38.11 4.12 36.38 36.38 4.56 34.50 34.50 5.05 32,41 3241 5.58 72 49.76 27.73 3.48 47.49 26,90 3.84 45.12 26.04 4.23 42.63 25.14 4.67 39,95 24.19 5.14 36.99 23.14 5.66 1575 67 45.71 35.04 3.46 43.61 34.19 3.82 41.42 33.32 4.21 39.13 3241 4.65 36.68 31.44 5.13 33,99 30.36 5.65 62 42.55 4213 3.45 40,89 40.89 3.80 39.17 39.17 4.20 37.34 37.34 4.64 35.37 35.37 5.12 33.16 33.16 5.65 57 42-52 42.52 &45 40.89 40.89 3.80 39.17 39.17 4.20 37.35 37,35 4.64 35.37 35.37 5.12 33.16 33.16 5.65 Multipliers for Determining the Performance With Other Indoor Sections Indoor Model Capacity Power Furnace Model Indoor Model Capacity Power Furnace Model *CAP**4221A** 1.00 1.00 CNPH*4221A** 0.99 0.97 315(A,J)AV036070 CAP**4224A** 1.00 1.00 CNPH*4821A** 1.00 0.98 315(A,J)AV036070 CAP**4817A** 0.98 0.98 CSPH*4212A** 0.98 0.96 315(A,J)AV036070 CAP**4821A** 1.01 1.01 CSPH*4812A** 0.98 0.96 315(A,J)AV036070 CAP**4824A** 1.01 1.01 CAP**4817A** 0.98 0.93 315 A,J AV048090 CNPF*4818A** 1.01 1.01 CAP**4221A** 0.99 0.97 315(A,J)AV060110 CNPH*4221A** 1.00 1.00 CAP**4821A** 1.00 0.96 315(A,J)AV060110 CNPH*4821A** 1.01 1.01 CNPV*4221A** 0.98 0.93 315(A,J)AV060110 CNPV*4221A** 1.00 1.00 CNPV*4821A** 1.00 0.96 315(A,J)AV060110 CNPV*4621A** 0.99 0.99 CAP**4224A** 0.99 0.94 315(A,J)AV066135 CNPV*4824A** 1.01 1.01 CAP**4824A** 1.00 0.94 315(A,J)AV066135 CSPH*4212A** 0.99 0.99 CNPV*4824A** 0.99 0.93 315(A,J)AV066135 CSPH*4812A** 1.00 1.00 CAP**4224A** 0.98 0.96 355AAV042040 FE4ANB006 1.04 0.95 CAP**4824A** 1.00 0.98 355AAV042040 FE4ANF003 0.99 0.94 CNPH*4221A** 0.98 0.96 355AAV042040 FE4ANF005 1.02 0.96 CNPH*4821A** 0.99 0.97 355AAV042040 FV4BNB006 1.04 0.95 CNPV*4824A** 1.00 0.98 355AAV042040 FV4BNF003 0.99 0.94 CSPH*4212A** 0.98 0.96 355AAV042040 FV4BNF005 1.01 0.95 CSPH*4812A** 0.98 0.96 355AAV042040 FX4CN(B,F)042 1.01 1 0.99 CAP**4817A** 0.98 0.93 355AAV042060 FX4CN B,F 048 1.04 0.99 CAP**4221A** 0.98 0.96 355AAV042080 FY4ANF042 1.00 1.00 CAP**4821A** 0.99 0.97 355AAV042080 FY4ANF048 1.02 1.02 See notes on pg.20 19 t DETAILED COOLING CAPACITIEStt (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES deg F AIR 75 1 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuht MBtuht MBtuht MBtuht MBtuht MBtuht CFM EWB System System System System System System Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** # # # # # # ,, 72 55,04 28.49 3.35 5262 27.54 3.75 50.08 26.56 4.20 47.38 25.54 4.72 44.49 24.45 5.30 41.25 23.26 6.01 1400 67 49.86 34.52 3,35 47.63 33.55 3.75 45.27 32.56 4.21 42.77 31.51 4.73 40.10 30.41 5.33 37.08 29.19 6.08 62 45.26 40.60 3.35 43.30 39.77 3.76 41.26 38.91 4.22 39.15 38.04 4.74 37.27 37.27 5.34 35.05 35.05 6.09 57 44.65 44,65 3.35 42.99 42.99 3,76 41.23 41.23 4,22 39.35 39.35 4.74 37.33 37.33 5.34 35.06 35.06 6.09 72 56.06 29.65 3.42 53.54 28.69 3.82 50.89 27.69 4.27 48.09 26.65 4.79 45.09 25,55 5.36 41.76 24.34 6.06 1600 67 50,79 36,35 3.42 48.45 35.38 3.82 46.00 34.36 4,28 43,40 33.30 4.80 40.63 32-17 5.39 37.50 30.93 6.14 62 46.36 43.45, 3 442 44.40 42.66 3.83 42.52 41.92 4.17 40.77 40.77 4.81 38.63 38.63 5.40 36.19 36.19 6.15 _ 57 46.41 46.41 3.42 44.64 44,64 3.63 42.77 42.77 4.28 40.78 40.78 4.61 38.63 36.63 5.40 36.19 36,19 6.15 72 56.83 30.71 3.49 54.22 29.73 3.69 51.49 28.72 4.34 48.61 27.66 4,85 45.53 26.54 5.43 42.11 25.32 6.12 1800 67 51.48 38.05 3.49 49.06 37.05 3.89 46.53 36,02 4.35 43.86 34.94 4.87 41.00 33.80 5.46 37.80 32.58 6.20 62 47.45 46.27 3.50 45.69 45.69 3.90 44.03 44.03 4.16 41,94 41.94 4.88 39.69 39.69 5.47 37.12 37.12 6.21 57 47.87 47.87 3.49 46.01 46.01 3.90 44.04 44.04 4.36 41.95 41.95 4.88 39,69 39.69 5.47 37.13 37.13 6.21 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Cooling Indoor Model Capacity Power Furnace Model Model Capacity Power Furnace Model *CAP**4821A** 1.00 1.00 CAP**4817A** 0.99 0.97 315(A,J)AV048090 CAP**4817A** 0.99 0.99 CNPH*4821A** 0.98 0.96 315(A,J)AV048090 CAP**4824A** 1.00 1.00 CNPH*6024A** 1.00 0.98 315(A,J)AV048090 CAP**6021A** 1.02 1.02 CSPH*4812A** 0.97 0.95 315(A,J)AV048090 CAP**6024A** 1.02 1 1.02 CSPH*6012A** 0.98 0.96 315(A,J)AV048090 CNPF*4818A** 0.98 0.98 CAP**4821A** 0.98 0.96 315(A,J)AV060110 CNPH*4821A** 1.00 1.00 CAP**6021A** 1.03 1.01 315(A,J)AV060110 CNPH*6024A** 1.02 1.02 CNPH*4821A** 0.99 0.97 315 A,J AV060110 CNPV*4221A** 0.97 0.97 CNPH*6024A** 1.00 0.98 315(A,J)AV060110 CNPV*4821A** 1.00 1.00 CNPV*4221A** 0.97 0.95 315 A,J AV060110 CNPV*4824A** 1.00 1.00 CNPV*4821A** 0.98 0.96 315(A,J)AV060110 CNPV*6024A** 1.02 1.02 CAP**4824A** 0.99 1 0.97 315(A,J)AV066135 CSPH*4812A** 0.99 0.99 CAP**6024A** 1.01 0.97 315(A,J)AV066135 CSPH*6012A** 1.00 1.00 CNPV*4824A** 0.99 0.97 315(A,J)AV066135 FE4ANB006 1.02 0.96 CNPV*6024A** 1.00 0.96 315(A,J)AV066135 FE4ANF005 1.01 0.97 CAP**4821A** 0.98 0.98 355AAV060080 FV4BNB006 1.02 0.96 CAP**6021A** 1.00 0.98 355AAV060080 FV4BNF005 1.01 0.97 CNPH*4821A** 0.98 0.98 355AAV060080 FX4CN(B,F)048 1.02 1.00 CNPH*6024A** 1.00 0.98 355AAV660080 FX4CN B,F 060 1.03 0.99 CNPV*4221A** 0.97 1 0.97 355AAV060080 FY4ANB060 1.01 1.01 CNPV*4821A** 0.98 0.98 355AAV060080 FY4ANF048 1.00 1.00 CSPH*4812A** 0.97 0.97 355AAV060080 CSPH*6012A** 0.98 0.96 355AAV060080 CAP**4821A** 0.98 0.94 355AAV060100 CNPH*4821A** 0.98 0.96 355AAV060100 CNPH*6024A** 1.00 0.98 355AAV060100 CAP**4824A** 0.98 0.96 355AAV060120 CAP**6024A** 1.00 0.96 355AAV060120 CNPV*4824A** 0.99 0.97 355AAV060120 CNPV*6024A** 1.00 0.98 355AAV060120 See notes on pg.20 20 DETAILED COOLING CAPACITIEStt (CONT.) EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES de F AIR 75 85 95 105 115M Capacity Capacity Capacity Capacity Capacity Total Total Total Total TotalTotal MBtuht MBtuht MBtuht MBtuht MBtuht CFM EWB System System System System SystemSystem Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** Total Sens KW** K1N** 123ANA060-A Outdoor Section With CAP**6024A** 72 67.65 35.66 4.15 64.56 34.48 4.58 61.30 33.25 5.06 57.89 31,98 Indoor1 5.58 154.20 30.63 6.15 50,10 129.15 6.77 1750 67 62.07 43.94 4.10 59.24 42.75 4,53 56.25 41.50 5.01 53.12 40.22 5.54 149.74 38.85 6.11 46.03 37.38 6.74 62 57.01 52.17 4.06 54.45 50.95 4,49 51.79 49.66 4.97 49.04 46.27 5.50 46.34 46.34 6.08 43.50 43.50 6.72 57 55.50 55.50 4.04 53.42 53.42 4.46 51.22 51.22 4.96 48.89 48.89 5.50 46.35 46.35 6.08 43.51 43.51 6.72 72 68.69 37.30 4.26 65.46 36.09 4,69 62.07 34.85 5.16 58.54 33.56 5.69 54.71 32.19 6.26 50.48 30.69 6.87 2000 67 63.07 46.60 4.21 60.11 45.38 4.64 57.00 44.12 5.11 53.75 42.62 5.64 50.27 41.45 6.21 46.44 39.94 6.84 62 58.17 55.80 4,16 55.57 54.47 4.59 52.95 52.95 5.07 50.49 50.49 5.61 47.78 47.78 6.19 44.74 44.74 6.82 57 57.57 57.57 4.16 55.35 1 55.35 1 4,59 152.99 1 52.99 5.07 50.50 50.50 5.61 47.78 47.78 6.19 44.74 1 44.74 6.82 72 69.44 38.83 4.36 66.10 37.62 4.79 62.61 36.36 5.27 5&97 35.06 5.79 55.04 33.67 6.36 50.70 32.16 6.97 2250 67 63.79 49.12 4.31 60.73 47.89 4.74 57.53 46.62 5.21 54.20 45,31 5.74 50.63 43.90 6.31 46.72 42.34 6.93 62 59.18 59.18 4.27 56.90 56.90 4.70 54.41 54.41 5.16 51.77 51.77 5.72 48.91 40.91 6.30 45.70 45.70 6,93 57 59.25 59.25 4.27 56.90 56.90 4.70 54.42 54.42 5.18 51.78 51.78 5.72 48.91 48.91 6.30 45.70 45.70 6.93 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Cooling Indoor Model Capacity Power Furnace Model Model Capacity Power Furnace Model *CAP**6024A** 1.00 1.00 CAP**6021A** 0.97 0.97 315(A,J)AV060110 CAP**6021A** 0.98 0.98 CSPH*6012A** 0.97 0.97 315(A,J)AV060110 CNPH*6024A** 0.97 0.97 CAP**6024A** 0.98 0.98 315(A,J)AV066135 CNPV*6024A** 0.99 0.99 CNPH*6024A** 0.97 0.96 315(A,J)AV066135 CSPH*6012A** 1 0.98 1 0.98 1 CNPV*6024A** 0.97 0.97 1 315(A,J)AV066135 FE4ANB006' 0.99 0.97 CSPH*6012A** 0.97 0.95 315(A,J)AV066135 FV461\113006 0.99 0.97 CAP**6024A** 0.98 0.97 315 A,J AV066155 FX4CN B,F 060 1.01 1.01 CNPH*6024A** 0.98 0.97 315(A,J)AV066155 FY4ANB060 0.98 0.98 CNPV*6024A** 0.98 0.97 315(A,J)AV066155 CSPH*6012A** 0.97 0.95 315(A,J)AV066155 * Tested combination. t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. t Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh (245 kW)per 1000 CFM(480 L/S)of indoor coil air for each degree below 80'F(27°C),or add 835 Btuh(245 kW)per 1000 CFM(480 L/S)of indoor coil air per degree above 80'F(27'C). **Total system kW is total of indoor and outdoor unit kilowatts. tt Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur. When the required data fall between the published data,interpolation may be performed. NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. 21 -'r.- � _. ■ fi t GUIDE SPECIFICATI6, S AIR-COOLED,6-%IT-SYSTEM AIR CONDITIONER GENERAL 12 1-1/2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1-phase Outdoor-mounted,air-cooled,split-system air conditioner type with class B insulation and permanently lubricated , unit suitable for ground or rooftop installation.Unit consists bearings. Shafts will be corrosion resistant. of a hermetic compressor,an air-cooled coil,propeller-type — Fan blades will be statically and dynamically balanced. condenser fan,and a control box. Unit will discharge supply — Condenser fan openings will be equipped with air upward as shown on contract drawings. Unit will be used PVC-coated steel wire safety guards. in a refrigeration circuit to match up to a packaged fan coil Compressor or coil unit. Quality Assurance Compressor will be hermetically sealed. — Unit will be rated in accordance with the latest edition Compressor will be mounted on split-post rubber vibration isolators. of ARI Standard 210. — Unit will be certified for capacity and efficiency, and Compressor will be covered with a sound absorbingblanket. listed in the latest ARI directory. Condenser Coil — Unit construction will comply with latest edition of ANSI/ASHRAE and with NEC. — Condenser coil will be air cooled. — Unit will be constructed in accordance with UL — Coil will be constructed of aluminum fins mechanically standards and will carry the UL label of approval. Unit bonded to copper tubes which are then cleaned, will have c-UL approval. dehydrated,and sealed. — Unit cabinet will be capable of withstanding Federal Refrigeration Components Test Method Standard No. 141 (Method 6061) 500-hr — Refrigeration circuit components will include salt spray test. liquid-line shutoff valve with sweat connections, — Air-cooled condenser coils will be leak tested and vapor-line shutoff valve with sweat connections, pressure tested. system charge of PuronO (R-410A) refrigerant, and — Unit constructed in IS09001 approved facility. compressor oil. Unit will be equipped with high-pressure switch, low Delivery,Storage,and Handling Unit will be shipped as single package only and is pressure switch and filter drier for Puron refrigerant. — Operating Characteristics stored and handled per unit manufacturer's — The capacity of the unit will meet or exceed recommendations. Btuh at a suction temperature of 'F. The power Warranty(for inclusion by specifying engineer) consumption at full load will not exceed kW. U.S.and Canada only. — Combination of the unit and the evaporator or fan coil PRODUCTS unit will have a total net cooling capacity of Equipment Btuh or greater at conditions of CFM entering air temperature at the evaporator at °F wet bulb and Factory-assembled, single-piece, air-cooled air °F dry bulb, and air entering the unit at conditioner unit. Contained within the unit enclosure is -F. all factory wiring, piping, controls, compressor, — The system will have a SEER of Btuh/watt or refrigerant charge Puron (R-410A), and special greater at DOE conditions. features required prior to field start-up. Electrical Requirements Unit Cabinet — Unit cabinet will be constructed of galvanized steel, — Nominal unit electrical characteristics will be v, bonderized,and coated with a powder coat paint. single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v Fans to V. — Condenser fan will be direct-drive, forward-swept, — Nominal unit electrical characteristics will be v, propeller type,discharging air upward. three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. ©Bryant Heating&Cooling Systems 7310 W.Morris St. Indianapolis,IN 46231 Printed in U.S.A. Edition Date:07/06 Catalog No.PDS 123A.18.2 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring o igauons. Replaces:PDS 123A.18.1 22 r .. ��- G``Y RESIDENTIAL MECniANICAL ;� o PERMIT APPLICATION t I N G� Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington,WA 98223• Phone (360)403 3431 • FAX (360)403 3447 THIS APPLICATION TO BE USED FOR ONE AND TWO DWELLING UNITS RESIDENTIAL STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS, AND TWO(2) SETS OF WASHINGTON STATE ENERGY CODE APPLICATIONS. Type of Permit: 1) Reside ial ( ) Commercial 17708 79TH DR2lF,Arlington WA 98223 Parcel ID#: 01047900011400 Project Address: Lot#: Subdivision: INSTALL BRYANT 3 TON A/C UNIT Project Description: Owner: RONNEY NELSON Phone Number: Address: Y� 17708 79TH DR SE -City: Arlington State: WA Zip Code: 98223 Contact Person: Naida Khan Phone Number: 360-945-2787 Cell Phone: 206-388-9357 Fax: 360-945-2091 E-mail: naida@nwpermit.com Address: 1345 Gulf Road City: Point Roberts State: WA-- Zip Code:98281 Please List quantity of fixtures Below: CLOTHES DRYER FURNACE UP TO 100K BTU GAS OUTLETS FURNACE OVER 100K FLR FURN INSTALURELOCATE SUSPENDED HTR/UNIT HTR1 APPL VENT/OTHER APPLIANCE REPAIR BOILER UP TO 3 HP BOILER UP TO 4-15 HP BOLIER UP TO 16-30 HP BOILER UP TO 31-50 HP BOILER 51 HP AND UP AIR AHNDLING UP TO 1OK CFM AIRHANDLING OVER 10K CFM EVAL COOLER VENTILATION FANS OTHER VENTILATION SYSTEM VENT HOOD DOMESTIC INCINERATOR COM/IND INCINERATOR ALL OTHER UNITS FREESTANDING STOVE FIREPLACE INSERT Contractor: WESCO Phone Number: 206-378-6644 Address: City: 2800 Thorndyke Ave W Seattle State: Zip Code:WA 98199 Contractor's License Number: WASHIES9710B Expiration: 09/02/09 I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. Applicants Signature Date Print Applicants Name �)'`` l' �% �P� ��,o , � � . RECEIVE �„�Qe� gut, o a zoos 1 `'D �A Forms/MECH-1 _ <-, �� � J • u� ' li • ' 1 11� '.i' 07-08-'08 09,57 FROM- T-702 P001f002 F-210 Northwest Permit Inc. 1345 Gulf Road Point Roberts WA 98281 360-945-2787- 364-945-2091: t r ! I To: City of Arlington Fax: 360 403-3418 i Attn:Brenda _ ! From: Adina Johon Date: July 8,2008 1 ns - - Re: Mechanioal Permit Aps Pages:2 CC: Urgent ❑For Review ❑ please comment ❑Please Reply ❑ please Recycle aM ' svthis application.Let me know when the permit is ready for pickup. Thanks! If you questions please call Tania or Adina at 360-945-2787 or email us at'-kiniac7i}.1,nJ.s�rnli[tl or elmit.coln. Tha A n Northwest permits Inc. RECEIVED JUL 0 8 2008 COA PERMIT CENTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . ,� i� � - .� BLD-Building Permit Ver: 2008B Priority. N.Im.l • 4BLD20080I75 oWner:INELSON,RONNEY status:JAPPLIED C r r address:117708 79TH DR NE,ARLINGTON post date: 7/8,12008 .ngrll data screens: select Screen... functions: Select Permit Function_.- r7WS al tRE �.iew Remove Review Prim close Description Review 11) r 2000 C-Building l CYOUNG 7,1E 2008 0 Y N ASSr.N { 2008 C-Community Development I BFECHT 7/15/2008 0 Y N ASSIGN r Done ! Local intranet °�100% ly i,.,.11 l •,-1 l - ,. �i l l - i I- :, i ..•. i i 1111 ..r, t �n �- rfi• -1JP, ,. 1 nd'Ly r �`'1.'.�)pi. ....., t.fir.11...-:I: i_,lJ:a1...fir l:l�:• , r.. . r., i...II. 1['Start U ;Inbox-Microso•.. J mach Permit aP•..I F PermitTrax-U•.. I 5earch Permit-... BLD20080L75... J ken « � 1120 AM Tuesday, Jul 08,2008 11:20 AM I 1