HomeMy WebLinkAbout17939 59TH AVE BLD 4_BLD20120292_2026 BUILDING INSPECTION REPORT 07i Permit No. l�_D�ZAddress: 17�39 Contractor:Owner: 40/ Date: 2 13 APPROVAL ® PARTIAL APPROVAL ® VIOLATION CORRECTION REQUEST Corrections listed below MUST BE MADE before work can be approved Please contact inspector Was not able to perform inspection Call 360-435-0674 FOR RE-INSPECTION by 5:00 pm the day before ff l2 nS /L All Inspector: Date: z4h, ® Under-floor ® Framing ® Gas Piping ® Footing ® Drywall, nailing ® Consultation ® Foundation ®Shear Nailing ® Groundwork ® Mechanical ® Grid ® Struct. Slab ® Wood Stove ® Rough-in XFinal ® Masonry ® Drainage ® Insulation ® Other: 1� ' - ��_. ."+,`•, {ref' .:1 _- Z, •tir: • { 4A • r •:jar; i,. r t I/ CITY OF ARLINGTON 238 N.OLYMPIC AVE.-ARLINGTON,WA 98223 PHONE:(360)403-3551 BUILDING PERMIT ' Addres s:17939 59TH AVE NE,ARLINGTON Permit#:BLD20120292 Parcel#:31052200403300 Valuation:$2,400.00 APPLICANT CONTRACTOR { ARLINGTON ADVANCED MANUFACTURING COMMERCIAL ALARM&DETECTION COMMERCIAL ALARM&DETECTION KRAUT HOUCK JAMES ROSE JAMES ROSE 3316 FUHRMAN AVE E,SUITE 200 17199 BENNETT RD 17199 BENNETT RD SEATTLE,WA 98102 MOUNT VERNON,WA 98273 MOUNT VERNON,WA 98273 Lic#:COMMEAD96I LS Exp: 11/02/14 'PLUMBING CONTRA. I " KCAL CONTRACTOR Lic#: Exp: Lic#: Exp: 40Bi'pESCRIP'I70 Fire Alarm PERMIT TYPE: Commercial-Business-Other CODE YEAR: STORIES: 0 CONST TYPE: DWELLINGUNITS: 0 OCC GROUP: BUILDINGS: 0 OCC LOAD: ENWAPPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX C ' its tKN . construction and construction materials in the City of Arlington must be reported on your sales tax return form and c d Cit f Arlingto c �2 2,1 Si re Print Name Date Rdleased By bat a ARCHIVE APPLICANT ASSESSOR OTHER BLD20120292 CONDMONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS, DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. • None PunirrFly - - Date Description Fee Amount Paid Balance Due 12/20/12 Fire Alarm(QTY:1) $88.50 SO.00 qUo 12/20/12 Building Plan Check Fee(QTY-.1) $100.00 $0.00 $100.00 Total Due: $188.50 $0.00 $188.50 CALL FOR INSPE(MONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon. df-52266:al •A2-260 MS-4(E) FIM-LITIaALarms Fire Alarm Control Panel by Honeywell Conventional General The Fire-Lite MS-4 and MS-4E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to con- ventional fire controls. The MS-4 is compatible with the i3TM smoke detectors from System Sensor, with drift compensation, maintenance alert, and freeze warning. Automatic synchroniza- tion of audio/visual devices with three selections for manufac- turer protocol.The Notification Appliance Circuit(NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The MS-4 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete list of compatible devices. Note:Unless indicated otherwise,the term"MS-4"refers to both MS-4 and MS-4E models. Features • Four Style B(Class B) Initiating Device Circuits(IDCs). • Two Style Y(Class B)NACs. • Optional module that converts all four IDCs and two NACs to Class A operation. • 24 VDC. • i3Tm Technology features: —Drift compensation automatically adjusts detector sensitiv- Msz, &Jpg ity and increases resistance to false alarms caused by dust accumulation. —Maintenance Alert LEDs (per zone) warn of excessive dirt • Silent or audible Walk Test operation mode commanded from accumulation, preventing false alarms (meets NFPA 72 the front keypad, with automatic return-to-normal after one requirements). hour of inactivity. —Detector sensitivity is automatically measured by the • Each zone may be programmed for supervisory or fire; each detector, which automatically adjusts its sensitivity back to zone has separate red and yellow LEDs. the factory settings when it becomes more sensitive due to • Zone 4 is programmable for combination of tamper supervi- contaminants settling in the chamber. sory monitoring and waterflow alarm. —Wireless handheld sensitivity meter eliminates the need for • Form-C Alarm,Trouble,and Supervisory relays. voltmeters, magnets, and a physical connection to the • 3.0 A total usable current. • 6.0 A total usable current available with optional second detector.The reader displays sensitivity in terms of percent transformer. per foot obscuration and provides text status indication. Control buttons: —Supervisory LED(per zone) provides warning if a detector —ACK(Acknowledge) senses temperature approaching freezing. —Alarm Silence —Special test protocol and LED indication allows quick test of —Reset —Walk Test all detectors without need for a ladder. —Zone Enable/Disable(one per zone) • NAC synchronization features: LED indicators: —Synchronization of standard ANSI audible signals as —Fire Alarm(one per zone) required by NFPA 72. —Supervisory(one per zone) —Synchronization of ADA compliant strobes per NFPA 72. —Trouble(one per zone) —Selectable for System Sensor, Wheelock, and Gentex —Maintenance(one per zone) protocols. —AC Power —Selective Silence feature for manual silence of horns —NAC Disable while strobes continue to flash on the same NAC. —Zone Disable —Alarm verification selectable for each zone. —NAC Fault —Disable switches provided per zone. —System Trouble • NACs programmable for: —Power Trouble —Walk Test —Silence Inhibit —Alarm Silence —Auto Silence —Earth Fault(on circuit board) —Strobe Synchronization —Battery Fault(on circuit board) —Selective Silence(horn-strobe mute) —Charger Fault(on circuit board) —Temporal or Steady signal Piezo sounder for alarm, trouble, supervisory and mainte- -Silenceable or Nonsilenceable RECEIVE®. nance. Optional plug-in 4XTMF transmitter module. nE,r , o on,) df-52266:al •03/10/09—Page 1 of 2 COA PERMIT CENTER • Optional plug-in 4XZMF zone relay module. • Maximum available current: 500 mA-appropriate for pow- • Optional 4XLMF transmitter module for RZA-4XF remote ering four-wire smoke detectors(see notes). LED annunciator. • Power-limited circuitry. • Optional dress panel. Notes: 1)Refer to the Fire-Lite Device Compatibility Document Operation for a complete list of compatible devices. Activation of a compatible smoke detector or any normally-open 2) Total current for nonresettab/e power, resettable power and fire alarm initiating device activates audible and visual signaling two NACs must not exceed 6.0 A for the MS-4(required optional second transformer). devices, illuminates an indicating LED, sounds the piezo sounder at the FRCP, activates the FACP alarm relay and oper- CABINET DIMENSIONS ates an optional module used to notify a remote station or ini- Door: 15.342" (38.97 cm) high x 14.667" (37.28 cm) wide x tiate an auxiliary control function. 0.375"(0.95 cm)deep. Backbox: 15.0"(38.10 cm) high x 14.5' (36.83 cm)wide x 3.0" Specifications (7.62 cm)deep. AC POWER-T63 BACKBOX MOUNTING • MS-4: 120 VAC,50/60 Hz,2.3 A. The cabinet can be surface mounted. The door is removable • MS-4E:240 VAC,50 Hz, 1.15 A. during installation by opening and lifting it off the hinges. The • Wire Size: Minimum 14 AWG(2.0 mm2)with 600 V insulation. cabinet mounts using two key slots at the top of the backbox and two additional 0.25"diameter holes at the bottom. BATTERY(SEALED LEAD-ACID ONLY)-J8 • Maximum charging circuit: normal flat charge 27.6 VCD @ Listings and Approvals 0.8 A. • UL Listed:S624 • Maximum battery charger capacity: 18.0 AH battery (two MEA:297-01-E 7.0 AH batteries can be housed in the FACP cabinet. Larger • CSFM:7165-0075:200 batteries require a separate battery box such as the Fire•Lite BB-17F). Ordering Information INITIATING DEVICE CIRCUITS-T63 MS-4:Four-zone conventional FACP;120 VAC,50/60 Hz,2.3 A. • Alarm zones 1 -4. MS-4E:Same as above,but 240 VAC,50 Hz, 1.15 A operation. • Power-limited circuitry. CAC-4: Class A converter module. Used to convert Style B • Operation:all zones Style B(Class B). (Class B)IDC to Style D(Class A)and Style Y(Class B)NAC to • Normal operating voltage: nominal 20 VDC. Style Z(Class A). The module connects to J1 on the MS-4 cir- • Alarm current: 15 mA minimum. cuit board. • Short-circuit current:40 mA maximum. 4XTMF:Transmitter module. • Maximum loop resistance: 100 ohms. 4XLMF: LED interface module. • End-of-line resistor:4.71K ohm,1/2 watt(P/N 71252). 4XZMF:Zone relay module,4 form C relay. • Standby current:4 mA. RZA:-4XF: Remote Annunciator. • Compatible devices: refer to the Fire-Lite Device Compatibil- BB-17F: Battery box, required to house two batteries greater ity Document no. 15384 for a complete list of compatible than 7 AH to a rrlaxiITIUM of 18 AH. devices. 411/411UD: Three-input (channels) model 411, and four-input NOTIFICATION APPLIANCE CIRCUITS-T62 model 411 UD, dual-line Digital Alarm Communicator/Tiansmit- • Two NACs. ters (DACTs). Can be used as slave communicators with the • Power-limited circuitry. FACP. • Normal operating voltage:nominal 24 VDC. DP-MS2/4:Optional dress panel. • Maximum signalling current: 2.5 A total with standard trans- MS-41313: Replacement board. former 5.0 A total (2.5 A maximum per NAC) with optional TRA-R:Optional trim ring for semi-flush mounting. transformer. A 2-zone version of this panel is also available.See DF-52211. • End-of-line resistor:4.7K ohm,1/2 watt(P/N 71252). • Compatible devices: refer to the Fire-Lite Device Compatibil- ity Document no. 15384 for a complete list of compatible devices. FORM-C RELAYS • Trouble Relay T135(fail-safe). • Alarm Relay T66. • Supervisory relay T137. • Relay contact ratings:2.0 A @ 30 VAC(resistive). Fire-Lite®Alarms is a registered trademark of Honeywell International Inc. AUXILIARY OUTPUT:RESETTABLE POWER-TB1 Bayblend®is a registered trademark of Bayer Corp. • Operating voltage:nominal 24 VDC. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements UVIIIYfMIN6 9MNYIFAMIUNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2-df-52266:al•03/10/09 7788F/ 7744F 'Series = ESlntelliNet CORPORATION I For Alarm Monitoring Wireless Fire Alarm CommunicatDrs for IntelliNet Features —All models • UL Listed commercial fire alarm applications. • Meets NFPA72 requirements • Direct reporting to AES receiver across IntelliNet mesh radio network • Each Subscriber acts as trans itterlreceiverlrepeater • Simple and fast activation on network i, On board status LEDs for easy set up • 8 programmable zone inputs—7788F • 4 programmable zone inputs and .t 4 reverse polarity inputs—7744F • Easy programming via AES handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application • Narrowband compliant Model 7788F @ LISTED Models 7788F/7744F-ULP with IntelliPro Fire also includes Advanced Wireless Alarm Monitoring IntelliPro Fire transmits full alarm data from As expensive dedicated Iandlines, required for UL864 compliance disappear, and the virtually any fire alarm panel digital future of GSM for alarm transmission becomes increasingly uncertain, the AES communicator IntelliNet mesh radio network continues to offer unmatched reliability and speed in Alarm format support for Contact ID,Pulse, delivering wireless alarm signals to a central station without any third-party fees or as well as Bosch Modem Ile and Modem Illa reliance on networks operated by companies outside the alarm industry. The Easy installation in AES subscriber 7788F/7744F Series Subscribers provide the wireless communications link between Operates in applications with or without a the fire alarm panel and the central station receiver. Ideal for most commercial fire phone line alarm applications, each 7788F/7744F Series Subscriber is housed in a full-sized, red, locked steel cabinet and supports a range of alarm panel inputs, including EOL fire, EOL supervised, and direct voltage from the panel (non-fire applications) — Supervised Operation AES Subscribers offer fully-supervised operation that includes monitoring of operating power(both primary AC and battery back-up)and the connection to the mesh radio network Each subscriber"checks-in"with the AES central station d receiver at least once every 24 hours The supervision check-in time can be set to as often as needed for the application, as appropriate for the network. Because the _ central station operates the wireless network, there is no additional cost for air time Wireless mesh networking is an innovative to transmit supervisory signals technology adopted by many industries with applications that need to communicate data over Full Data Reporting from Alarm Panel Digital Dialer a large geographicv,area with a high level of reliability Models 7788F-ULP and 7744F-ULP come equipped with an IntelliPro-Fire Full Data total cost of Module(AES-7794)which enables reporting of full alarm data captured from the The advanced ownership. a low wdesign and o way alarm panel's digital communicator. IntelliPro-Fire supports most alarm communication communications capability provides easy formats including Contact ID, Pulse, as well as Bosch Modem Ile and Modem IIla2 installation,expansion,and management when (when converted to Contact ID format). compared to alternative communication methods, both wired and wireless. 7744F/7788F Series ES�lntelliNet CORPORATION For Alarm Monitoring Technical Specifications 7788F/7744F Series Subscriber Dimensions Antenna Cut/Communication HOW to Order • 13.25"H x 8.5"W x 4.3"D Trouble Output Model Description (34cm H x 21.5cm W x 11 cm D) Form C relay;fail secure; 7744F 4 Zone Fire Alarm Subscriber with 4 Weight rated for 24 VDC 1A resistive reverse polarity inputs • Approx.7 pounds(3.2 kilograms), Reset Button excludes battery. • Located on main circuit board. 7744F-ULP 7744F Fire Alarm Subscriber with Radio Frequency Operating Temperature IntelliPro Fire full data module • Standard Frequency Range: • 0°to 50'C(32'to 122°F) 450-470MHz Storage Temperature 7788F 8 Zone Fire Alarm Subscriber (others available in 400-512MHz range) • —10'to 60*C(14'to l40°F) • Output Power—2 Watts Relative Humidity 7788F-ULP 7788F Fire Alarm Subscriber with Antenna • 0 to 85%RHC,Non Condensing IntelliPro Fire full data module • Included 2.5 db tamper resistant antenna mounts on enclosure AES-7794 IntelliPro Fire Optional Accessories • Multiple remote antenna options available Packaged with 7744F•ULP and 7788F•ULP 7041E Subscriber Handheld Programmer Power Input Input/Output Connections • 16.5VAC,40VA transformer(not included) RJ11 connection to AES subscriber for module 7794 IntelliPro Fire Full Data Module (AES 1640, ELK TRG1640,MG Electronics data and power MGT1640—UL Listed for use) RJ11 connector for Handheld Programmer/PC 1640 Plug-in Transformer: 16.5VAC,40VA Backup Battery programming • Will charge 12V battery up to 7.5 AH. Requires RJ31 X Telco connections-T and R both in 12VDC 7.5 AH battery for UL 864. and out via terminal strip and RJ45 Alarm Signal Inputs(subscriber) Alarm Panel digital communicator T and R • 7788F—8 individually programmable zones both in and out via termina strip and RJ45 • 7744F—4 individually programmable zones Trouble output:Form C relay detects if and 4 reverse polarity inputs Subscriber is off the network UL Standards Alarm Formats • UL 864 Edition 9—Standard for Control Units Support for Contact ID and Pulse formats as and Accessories for Fire Alarm Systems well as Modem Ile and Modem IIla2 converted .''�••; : , • UL 365—Standard for Police Station to CID stCutrlrY Connected Burglar Alarm Units and Systems Size I r,;,;, ,, NETWORK • UL 1681 —Standard for Central Station Burglar • 2.8 x 5.0 inches(7.1cm x 12.7cm) •��-^ aAMERICA Alarm Units Power Requirements • 12 VDC nominal-primary and backup power 1 provided by the AES 7788FI7744F or other U` NFPA Subscriber AES-IntelliNet'"is the industry leader in delivering high-quality mesh radio networks to the fire and security industry in commercial,corporate,government,and educational applications with its broad line of products and advanced network management tools.Users of AES-IntelliNet networks have gained significant revenue,communications,and cost advantages while meeting the high standards of reliability required for the fire and security industry.AES-IntelliNet alarm monitoring systems are deployed at hundreds of thousands of locations in over 130 countries, - FRAIT§ION� ntelIiNe tCORP For Alarm Monitoring For more information Call 800-AES-NETS (800-237-6387) AES Corporation 1 285 Newbury Street I Peabody, MA 01960 USA Copyright 2012 AES Corporation Tel. +1 978-535-7310 1 Fax+1 978-535-7313 AES-IntelliNet is a registered trademark of Email info@aes-intellinet.com I Web www.aes-intellinet.com AES Corporation 7788-7744Fi1/121R4 BLD20120292 (PT-LIVE) - PermitTrrax by Bitco Software Page 1 of 1 BUILDING PERMIT PERMIT#: BLD20120292 1/ OWNER:ARLINGTON ADVANCED MANUFACTUR... STATUS: APPLIED ADDRESS: 17939 59TH AVE NE,ARLINGTON BALANCE: $0.00 ISSUED: CREATED: 12/19/2012 SCREENS: Select Screen... FUNCTIONS: Select Permit Function... COMMERCIAL-BUSINESS-OTHER REVIEWS PRINT ADD NEW SUMMARY COMME... ID DESCRIPTION ASSIGNED.. DUE DA... LAST (#) REQ? DON... ASSIGN REMOVE 2000 C-Building I CYOUNG 12/28/2... 0 Y N %a 2008 C-Community Developme... ARUSKO 12/28/2... 0 Y N �j 3004 X-Fire TCOOPER 12/28/2... 0 Y N https:Hcoapermits.arlington.local/PermitTrax/Module_Permits/Permits_Permit/Permit Reviews.... 12/19/2012 a �_ - a I FIRE ALARM PERMIT APPLICATION Department of Community Development City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX(360)403 3447 THIS APPLACATION MUST BE ACCOMPANIED BY FOUR(4)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) 0 New Fire Ala r �d (]) Fire Alarm Alteration/Addition Project Address: ` I S A), Parcel ID#: j 0 a 00 ®13 O o Number of Zones/Panels Building Area(Sq Ft): Valuation: Owner: fT��i rth�lly� Qi�C�.nC-e,0 w.", P4 k Phone Number: 3 3I� FuhrP7d,,, ,4"� s¢e�o� . Address: City: � �!l t State: ablL Zip Code: Contact Person: .zj(k.0le-S �1a' Phone Number: Cell Phone: Fax: E-mail: Address: City: State: Zip Code: Contractor: 0—p—tnpy) orri A_L A_4& ,v1 t- be C-it-iL Phone Number: 36%O— 9 4(F?— Address: 1 ')CI q ,e�1 iy l city: !?t�ri� ��°�tu,ad State: Zip Code: W,�L 7 3 Contractor's License Number: L �.�� �� Expiration: a J a 0 )� Electrical Contractor: h1C Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. The applicant will be responsible for providing a method of safely accessing roof for inspection. A final inspection and approval shall be obtained when the re-roofing is comp) Applicants Sig ature Date ehr.-, 'hite &. Aer Print Applicants Name RECERIED FOR STAFF USE ONLY &bA19-b?qc?- DEC 18 2012 Permit It Accepted By Amount Received Receipt# COMER TICENTER WEB Form—130 Page 1 of 1 4/04 sb <r. �. � � ,�, i ��'� Commercial Alarm & Detection, Inc. Transmittal 17199 Bennett Road Mount Vernon WA 98273-9789 Date: 12-17-2012 360 848-1533 License: COMMEAD961LS To: City of Arlington Project: 12126 238 N. Olympic Ave Arlington Advanced MFG#4 Arlington WA 98223 17825 59th Ave NE Bldg#4 Arlington WA 98223 Prepared By: CHRISTINE COOPER Item Quantity Description 1 Permit App 4 Plans 4 Cutsheets RECEIVE® Please sign and date this form as proof that you are in receipt of the above listed items. Return form to Commercial Alarm& Detection, Inc. orc 18 2012 Signed. Date ;OA PERMIT CENTER -6L)Q 2-�o I d-D 2- I 198tn 9xNE Pe"'Rd 61 G 10M t h 1 �601tt?1 NE'. 'S" . R S'"},= tsai S IE Park ne Sl9pih 9t N€: 'i08[h 3Y NE t y +� " ggI Ali . RXoX 4 �4 - F AOIThe j x t. .r' y` N annex t - r1 A�tuS�ton ME .`.y I p m, ,r PROJECT a T ` �ea�n scram `P k'' aR u « LOCATION )7141 PI NE , , i Y 'E'J:i'3'.E # Z \ ' raRfN'Fiht q NMI nPlRE, rKiinN114 E' GI qP INE �r 1 'S m'ktM.pu^a,1 FPI Nf e , RV Pard-� g 1Y',V E1 N£ . S - - -i M. St} ,;v A g A g dt E.d9ecomW Rd 51 _ �_d�72rn5t NE.., r,✓,lSTLnd S.NF .� +. r ,q,SINE- VICINITY MAP N SCALE:NTS AREA OF WORK BUtL0111AG#4 \--_ 180TH STR T N - ASSEMBLY J `od O - -- UI® REOET . E� G < 6WIi0H J n "V PmPemmerPoR - J .a I Electncal M Room AES:748$ FIELD WIRING 18.UA G Z1 G 2Z Z3 G Z Z5 Zs Z7 'thr,.I� E'- pt� l5i 1fi5VAC �--------------- 7AH j -- Battery a o ; ` ARLINGTON ADVANCED MANUFACTURING: SITE PLAN o 9 NJ SCALE:NTS x W € CENTRAL STATION ZONE LEST �lu ;DJ: Z DESIGN CRITERIA y /� {/ ( DESIGNED PER ED 2009 EDITION 1 General Fire Alarm i ��///f/�r"� �Q •J� I INS ALLIED PER NFPA 72-2GO7 EDITION Va✓r�Y V INSTALLED PER NFPA 70-2DO8 EDITION BUILDING#4 2 General Supervisory C,<� V � N rq V u d m FLOOR 2 i o 0 0 0 2 Main Panel Trouble R SCOPE OF WORK hgr COMMERCIAL ALARM&DETECTION(CAD)WILL SEPARATE BUILDING N4 i � /• I v FROM THE FORMER BRUNSWICK BOAT YARD FIRE ALARM SYSTEM FOR 0 Sri m. = v.00 LOCAL ZONE LIST INDEPENDENTSERVICE. ALL EXISTING BUILDING FIRE ALARM SERVICE WILL REMAIN UNCHANGED APART FROM INDEPENDANT /� MONITORING AND DISPTACH.THIS WILL BE ACCOMPLISHED THROUGH ®O 2 PUII Sta♦LIOnS THE ADDITION OF A NEW CONVENTIONAL FIRE ALARM PANEL AND IDC TWO-WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON FREQUENCY Cop- 3 465.9875 mhz LICENSED TO ALARM CENTER OF LACY WITH THE FCC IDC 3 Sprinkler Waterflow THIS UNIT WILL COMMUNICATE TO CENTRAL STATION THROUGH EEE MINIMUMOF TWO GOOD PATHS WITHA Ne n OF50R LESS THESE IDC 4 Sprinkler Tampers PATHS CAN BE DOCUMENTED UPON REQUEST ORVERIFIED DURING (�44� FINAL INSPECTION. O O Ea MI ® IT1' OF ARLINGI 0 NFPA 72 REFERENCES eUlLolr DEP RIMENT A P ` r R THE BE FOUND AT REFERENCES FOR WIRELESS RADIO TRANSMISSION 'rMl` t�C t�{^!� CAN BE FOUND AT: FLOOR PLAN - _ NFPA ED,2002 85,3.5lrABLEA 85.1 DATE 1'1 '/�� Z �/✓//)�II�A��/7 NFPA ED 2010 86 ITABLEA881 N SCALE:NTS FIRE ALARM SYSTEM RISER DETAIL N „ A A6Y 1/ TM--- "EPA ED 2010 266332 ABLE A2881 ZED I( UgLESS Af P (C PV iNC4— All `"G'" BUILDING Notes: SCALE:NITS existing devices and wiring to remain. I - - --- _ -__-__--.-_ _._ ABBREVIATIONS REVISIONS :oNTer„ wn-ri CABLE—CODES — DEVICE LEGEND CODE FUNCTION DESORIPTION,NEC TYPE CABLE ROUTING SYMBOLT.MANUFACTt1RER TYPE MODEL GANDEtA MQUNTiNG QTY a�� ocR NO. _TA eY REi�soN FOR REVISION _ t COMMERCIAL ALARM&DETECTION, INC. EACP FIREl1TE'F1RE ALARM CONTROL PANEL MS-4 1 Advanced Business Park :] n BEENFTT ROAD -- - Advanced k AES AES _ RADIO 9JBSCRIBER UNIT 740E 1 E MT V RNOY tNA 96273 AES 3IXB ANTENNA — 1 — 1A782FJ9 h Ave NE LICENSE PIX)MMEA1948L0 i t `.O F ExlsnNc mst G MANUAL PULL STAION _-nr -. _ -_ Arlington,Wa98223 f _ - - -- -_ - - --- -_.. — -- LE I PHONE:136' 648 1633 FAX (36D)848 tOT2 _ EYJSIING IXISIING WATERFLOW SMTCH MODULE --. - - i IXI611NG IXRN_G..TAMR MiCN M000LE --. -' - -_- PROJECT MANAGER:Kat Nouk i Arlington Manufacturing cturing Pa rk wNawmE Building#4AJSEMBLY PHONE:360-333-2556 RECEIVED i N 17825 5 h Avenue N ---. _. - - S�!t'ERtHTE4t:FttT F:'..t.S zQtz ! Arlington Washington 98223 AUTHORITIES HAVING JURISDICTION:City of Arlington PHONE t - - -- ---- - De t of Labor and Industries FAx: g'+ r C oRnwry-1v cl+eelceo sv- DarE: sHEeT- abeo.:N t -- ----- - - - --� - — —� P KEY PLAN -" � ��p CENTE JR t35 12111712 1 OP 1 12-126