Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
199th St Ne_BLD5513_2026
8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com Comment Letter on Permit 5512/5513 August 9, 2023 Jeff Lincoln Air Gas USA LLC 5925 199th St NE Arlington, Wa. 98223 Hello, I am reviewing your permits for a propane tank and dispenser at the Air Gas facility. I came down and I was told there was previously a dispenser. I just need to make sure the dispenser and tank comply with the Fire Code. As you are in the business, I am sure you are aware of the distances, I just need to verify. I have the sketch and the table on the following pages. I also need to know what type of impact protection there will be for the tank. The area is pretty tight as you come in and the tank/dispenser will create more congestion. I have a spec on bollards if you need them. • Weeds, grass, brush, trash and other combustibles shall be not less than 10 feet away from the LP-gas tanks or containers. • The other gases in storage use would need to be 25 feet away from the filling area. On the day I was there I was not sure you had the distances • Each industrial plant, and distributing point shall be provided with at least one portable fire extinguisher in accordance with Section 4.7 having a minimum capacity of 18 Ibs with a B:C rating within 30 feet • No smoking signs within 25 ft of filling station 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com 30.000 GALLONS EACH UNDERGROUND S,000 GALLONS SO•-0'MINIMUM MINDALAM —5'-0'MINIMLAM STREET 25'-0-MINIMUM i i ® i -No GALLONS ' BUILDWO Y-WMINIMUMJ ® -•---•-.- 10'4r 2S'0' � BUILOfJG7-25-4r 1.000 GALLONS 4. Ply 000 GALLONS EACH �I NOTE:ALL LPG CYUINOERS.ALL ABOVE GROUND EXCEPT WHERE NOTED_ 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com y RL 1116TON a Al VZc,A-s Ulg R E H0145 E 0 Fe,ce - l 1 _ AAQJ. S� of /t{Dg..c rMk C,ATJE I I �1 uo �o c� } Q This is the table I am working from 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS MINIMUM SEPARATION BETWEEN LP-GAS CONTAINERS AND BUILDINGS,PUBLIC WAYS9 OR LOT LINES OF ADJOINING PROPERTY THAT LP-GAS CONTAINER CAPACITY CAN BE BUILT ON MINIMUM SEPARATION BETWEEN LP-GAS CONTAINERS'c (water gallons) Mounded or underground Above-ground LP-gas containersb (fit) LP-gas containers' (feet) (feet) Less than 125`d 10 5e None 125 to 250 10 10 None 251 to 500 10 10 3 501 to 2,000 10 25'1 3 2.001 to 30.000 50 50 5 30,001 to 70.000 50 75 70,001 to 90.000 50 100 (0,25 of sum of diameters of adjacent LP-gas containers) 90,001 to 120.000 50 125 For SI 1 fat=3048 min 191111n=3785L a.Minimum distance for underground LPgas containers shall 4 measured hom the pressure relief device and Me filling or Ipad-level gauge vrnl connection at the container.except Mat all parts of an undegound LPgas cmtainer shall be nbt kss than 10 feet from a building or lot In,of atioining abcedy Mal can be buin on b.For MM1er Man installations in rMicM1 the osreManging strvdure rs SO feel or more above Me relief-valve discharge w0et.In applying Me tlistance behveen buildings ant ASME LPgas containers wiM a wafer capacty o1125 gallms or more.not less Man 50 percent of Mis M1ori_ontal distance shall also apply to all podinns of Me WIdbg Mat pr 1more Man 5feet from Me bmldmgwall and that are higher than Merelief valve discharge bullet This ho,cbntal distance shall be measured from a point del—alb by pbbding Me outside edge o1 such overhanging structure vbin-Hy damvrad ro grate a other I...I on which Me LP-gas container is installed Distances to Me Wilding wall sM1all be not—than Mole p—bet in th5 table c._underground multiconlainer installations an,—p—a.1h.�itlual LPgas containers daring awaler c-ty of 125 gallons in more.such containers shall beinstalled so asto Ina—access at their entlsasides to faubale v:o st—cranes a hoists d.Ataconsumer stle if Me aggregate watercapacily ofa multiple.obtainerinslarabbn comprised of individual LP-gas containers raving.water -tybfless than 125 gallons.,500 gallons or more.Me minimum distance shall cbmpl,vnlh the appropriate poNm Ott"table applying the aggregate ceDacitY ranter Than Me capadty per LP-gas container If more Than one such installation is made each inslallalim shall W sepa,alet from olds indallafims by nd less Man 25 n-Minimum distances behreen LPgaz containers need nM be applie0 e.Tlie follovdng shall apply to aboveground cl ntai,rtrs installed alorgsitle b.b iN, 1.LPgas containers o1 kss Man a 125ga11mwafer capacity are all—wiM a separation tlislanm wherein ca.pliancew nth Items 23 and 4. 2.Depadmrnt of Transpbdation IDOTni specification LPgas containers shall De located and installed w that the discharge hom the container a—Iin,bt,f device Is not kss than 3 feet horizontalry bbbi buiking oprnngs bdov:the level of—discharge and shall nd ce'meant buikings unless the space is well v..blatetl to In,outside and It not enclosed for more Man 50 percent of ifs perimeter Th,discharge from LP-gas container aessure relief devices shall be locaret nor less Man 5 feel from eAedor sources of ignition openings into tired-vent lsealet omb-bi,syslemi al%rbances a mechanical ventilabm air Intakes 3.ASME IPgaz-tamers of—than a 125yallon ware,c,p,,ty shall beocated l and Installed such that the discharge tram essu prre,tlief d,,,a shall not tmminate In or beneah buik—till, and shall be located not less Man 5 f or�on fiat hrally from baiting openings W=the Iesal of sucM1 tiuhargecand not less Man 5 feel ham eAedor sources of ignition.openings into direct vent isealetl combustion syslemi appliances.or mechanical—hahb,air intakes. 4.The filling connection and Me vent from liquid-level gauges on either DOT.or ASME LPgas containers filled at Me point of installation shall W not less Man 10 1-1 from ededa swrtes b1 ignition openings into direct vent IsealM canWstion syslemi appliances or mechanical ve b abbe air intakes f.TNs tistance is aIt.-tb be r...d to not less Man 10—Ior a single LPgas cmtainer M 1200-garon water capacity or less.provitet that such container is not less than 25 feet I——LPgas containers of more than 125-galkn v,ah,.capacily. g.Aboveground LPgas containers th av:a capacily o12 OOD gallons or less stall be separated hom hbI.ways by a distance of not less M an 5 leer Containers—awaler capacity It,—,Man 2000 gallons stallbe separated flan pudic ways in—dance vah thistable. Steve Goforth,Assistant Chief/Community Risk Reduction North County Regional Fire Authority 8117 267111 St NW Stanwood,WA 98292 Office 360-629-2184 x105 Cell 360-502-6184 sgoforth@northcountyfireems.com "Serving our Communities with Compassion" Serving the Cities of Arlington and Stanwood,the rural communities of Bryant,Freeborn,Warm Beach, Kayak Point and the Stillaguamish Tribe of Indians. CONFIDENTIALITY NOTICE This e-mail message,including any attachments,is for the sole use of the intended reciplent(s)and may contain confidential,proprietary,and/or privileged information protected by law. If you are not the intended recipient,you may not use,copy,or distribute this e-mail message or its attachments. If you believe you have received this e-mail message in error,please contact the sender by reply e-mail and telephone immediately and destroy all copies of the original message.Thank you ' OPERATING PERMIT APPLICATION Department of Community& Economic Development City of Arlington- 18204 59th Ave NE-Arlington.WA 98223-Phone(360)403-3551 Part I Applicant/Building Information Applicant's Name: Air Gas Arlington Applicant's Address:5925 199th St NE, Arlington, WA 98223 Contact Person: Kelly Kite Telephone:253-380-0286 Address of Premises for which Operating Permit is requested: © Same as above ❑Other(specify): Tax Parcel ID#: 00746300000100 Current Occupancy Class:General Industrial Part II Type of Operating Permit An Operating Permit is required to conduct any activity or to use any class of building listed below. Please indicate the type(s) of Operating Permit(s)requested by checking each applicable box. (If you require assistance,or would like more information,contact the City of Arlington Building Department at 360-403- 3551.) ❑ Manufacturing, storing or handling hazardous materials in quantities exceeding those listed in the Fire Code(see Appendix A.)Identify the materials and quantities and describe the manner in which the materials will be manufactured, stored or handled (attach additional sheets if necessary): Revised 4/l/08 Page 1 of 4 Part H (cont'd) ❑ Conducting a hazardous process or activity, including, but not limited to, any commercial or industrial operation which produces combustible dust as a byproduct,fruit and crop ripening, waste handling, spray operations, and high-piled storage (see Appendix B.) Describe the process(es)or activity(ies)to be conducted (attach additional sheets if necessary): ❑Use of pyrotechnic devices in assembly occupancies (see Appendix C.)Describe the devices to be used and type of event(attach additional sheets if necessary): © Aboveground Storage Tank(AST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanenttankclosur Brief description: installing a 1000 gallon propane dispensing unit ❑ Underground Storage Tank(UST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑Temporary Membrane Structures, including tents and canopies (see Appendix E.)Brief description of structure and use: Cc: Fire Department Page 2 of 4 Part H (cont'd) ❑ Special Event Operating Permit -An Operating Permit is required for any special event that takes place within an occupied building, or an outdoor mass gathering,which is outside the scope of the permitted use (see Appendix F.) Brief description of type of gathering proposed: Pdrt III Premises/Building Information 1. Date of last inspection of Premises: 2. Has a Certificate of Occupancy been issued for the premises? 2 Yes ❑No Type: ©Permanent ❑ Temporary Date of Issuance: 3. Are there currently any open Building Permits associated with the premises? Yes ❑ No If yes,please describe(attach additional sheets if necessary): Permit #: 5424 4. Additional Comments: SIGNATURE OF APPLICANT I herby certify that the foregoing information(and all information in attached sheets,if any) is true and complete. aSid�sa�aesooe.com 07-28-2023 1gIici�uia sv °riYjiva aii or Authorized Representatives Signature Late Kelly Kite Name and Title (if applicable) of person signing Application (Please print) Cc: Fire Department Page 3 of 4 Part IV To be completed by the City of Arlington Building Department Inspection Required: ❑ Yes ❑ No Inspections Performed: ❑ Yes ❑ No Date of Inspection: Tests or Reports required verifying compliance? ❑Yes ❑ No If YES, have Tests or Reports been received? ❑ Yes ❑ No Application(s) Approved: ❑ Yes ❑ No Operating Permit Issued by: Date Operating Permit Issued: _ Date Operating Permit Expires: Type/Description of Operating Permit: Conditions of Operating Permit(list conditions here AND in the space provided in the Operating Permit): Additional Comments: (Attach additional pages if needed) Cc: Fire Department Page 4 of 4 9 v� cy Fe+nce6 r�3 i I i Z ct 3�5' i PRODUCTS, INC. PDM Style Dispenser Designed to Meet and Exceed NFPA 58 Requirements Utilizing UL Approved Equipment M NYy Teeco Products, Inc. 7471 Reese Road, Sacramento, CA 95828 Phone 800-225-6621 www.TeecoProducts.com PRODUCTS, INC. PDM Series Dispensers Specif ications Galvanized Steel Cabinet Dimensions: 42" W x 22" D x 59" H RL1001" Type 4D-MD Neptune Meter w/ Model 600 Register Pump of Choice - Smith / Corken / Blackmer Manufacturer's Bypass RegO A2141A6 3/4" Pull-Away RegO 7554LV 3/4" Quick Acting Fill Valve RegO A75751_3 3/4" x 1 3/4 ACME Adaptor RegO 3146S 3/4" Soft-Seated Back Check RegO 3125L External Hydrostatic Relief Valve RegO 3272G 3/4" 15 GPM Excess Flow Valve RegO A7706P 3/4" Angle Valve SS8021 L RegO External Hydrostatic Relief Valve 15 foot Parker 3/4" Delivery Hose RegO A75751_3 3/4" Extended Type Hose Coupling Explosion-Proof ON/OFF Switch wired to motor Forged Steel Pipe Fittings Unit completely tested for leaks Meter tested and calibrated Dispensing Unit meets or exceeds NFPA 58 requirements Utilizes UL Approved Equipment RED SEAL TS-285(G .MEASUREMENT TYPE 4D-MD L.P. GAS FLOWMETER 66 1 " ALUMINUM BODY ' ' ' ' ' DISPENSER METER DESCRIPTION The Red Seal 1"Type 4D-MD meter, with double case design has been specifically designed for the custody transfer of liquefied propane and butane gas (LPG). This meter utilizes the oscillating piston positive displacement measuring chamber technology. The 1"Type 4D-MD is particularly suited for filling portable gas bottled and fuel containers for portable burners, pavement heaters, weed burners, fork lift trucks and motor fuel tanks. The standard unit includes the base meter with the choice of either a 600 Series totalizing register with a resettable counter or an 800 Series printer register.A differential control 1" 4D-MD with 600 Series Register valve, combination vapor eliminator/strainer, continuous bleed pressure relief valve and tubing kit are also included. An optional automatic temperature compensator(ATC) is available. The ATC senses product temperature and adjusts OPERATING SPECIFICATIONS the readout to result in registration that is compensated to 15°C (60°F). Flow Rate LPM US Gal./Min. Maximum 68 18 Minimum 11 3 DESIGN FEATURES Operating Pressure Bars PSI SUPERIOR ACCURACY Maximum 24 350 Minimum See Note The Neptune designed oscillating piston measuring chamber is both accurate and reliable. The piston is treated with a Operating Temperature °c °F special coating which protects it from damage by impurities (without ATC) and adds lubricity for smooth performance at low flow and Maximum 60 140 high operating pressures. Minimum -23 -10 FLEXIBILITY Temperature Compensation(ATC) Rugged outer body components in a compact design make Compensates to a basepoint of 15°C(60oF) the 1"Type 4D-MD useable in a wide variety of installation Range: -23°C to 52°C(-10°F to 125°F) configurations. The meter is also available with several Connections different register options, and in temperature compensated Ductile iron companion flange tapped for 3/4"std.pipe and uncompensated versions. Optional ductile iron companion flange tapped for 1"std.pipe UNITS OF MEASURE Note:A minimum of 1.034 bars(15 psi)is needed to open the dif- Neptune 600 and 800 Series registers offer a full range of ferential control valve,plus pressure loss in the system. options for calibration in U.S. gallons, Litres and Imperial gallons, with 5 digit reset and an 8 digit non-resettable totalizer. www.redsealmeasurement.com DIMENSIONAL DATA, mm (in.) 1" 4D-MD with 1" 4D-MD with 1" 4D-MD with 600 Series 800 Series Register 600 Series Register Register, pulser, and ATC and pulser 67 Myd (a°M11 tf14 (1°/a 14 NPT --- Om nt CNNOulm W4 1 86 3/4 NRT mil CILITW 3/4 fIQNp 93 " INLJS(AND OUTILIT (34W ----__ os r►se1 --- --- 3"CLEARANCE FOR (BrIrW REMOVING REGISTER t 'ECLEARANCE L_.. —4tA t s� FOR REMOVING REGIS I 2-CLEARANCE YING REGISTER 87 Wks) 406 i z (t61 1/ (14Y.) 412 114 mm(45i) �110 1� 194 20 CLEARANCE (4.1.) FLARED TUBE FOR REMOVING 60 (z 1 FITTING STRAINER 114 mm(41h) CLEARANCE FOR REMOVING Bottom View STRAINER WO (4%.) 60All Configurations (2') CLEARANCE %j 18 UNC 28 FOR REMOVING 110__1 60 (3 HOLES) STRAINER 1 I � 1 Specify Genuine Neptune Replacement Parts Accuracy of all Neptune Type 4D Custody Transfer Meters for use with L.P. Gas and Butane meets or exceeds N.I.S.T. Handbook 44 Parameters. 1310 Emerald Road IsCoiaR11a20IW Greenwood, SC 29646 USA RED SEAL L, Phone: 1.800.833.3357 MEASUREMENT ��"�,! TOVNIeMIenO Fax: 1.864.223.0341 1* iw �-^^^ m,.�.oa..o. Excess Flow Valves for Liquid or Vapor 3272 Series,3282 Series,3292 Series,A3272 Series,A3282 Series,A3292 Series,7574 and 12472 F - % G`'m Closing Flo�Range WE--.. __... .■. .. loon �.■■..111...I n I o.ME.cu . io1 "pl 1■■■���■■■1111■■11 ... .e�i..... n.�n .■n.1O. ._ I■111�■■■111111■111 ' . 111/ii ■■Illn!111 "111 IIIII■■■■1111111111 � ,111■■�:illlllllll■��J1�IIII1111 ��I■■iiiiiiil1111■■■■Irlllll�ll • 111�_�_■_■��IIII��mm1MlM=M mom /:`��i%�1111■�11 ' �.��.■.....i....��.6�...11.■.Mon m Mom. �11�■■.��1111��11—%1■■■IIIII■111 "••1 111��%IIIIIIII�iII�■11111111111 'C.1����■■..IICAI���■■■1111■■11 1__!;�■■Il�:iilllll■■■11111111111 .Illii■■1�!:n■111�■■■111111■111 111�■'.■111111111�■■■■11111■111 �:��■�:illlllllll■■■■1111111111 11��%�11111111111■■�11111111111 III��IIIIIIIIIIII■■111111111111 _ • • . • • - • • •- B 1) PF proximate Closing Fl Outlet Effective Vapor SCFH(Pro ne art Brass or Inlet Connecti Connection Wrench Length p umber Steel (M.N (F.NPT) Hex Flats (Approx.) Liquid(GPM Propane) 25 PSIG Inlet 100 PSIG AM 1 1 11 ® ® 1 11 11 ® :11 111 �_� � 1 11 . •11 1 11 .11 �_� � 1 • 111 . 11 1 111 111 11 .11 1 1 1 1 / 1 1 1 1 e 1 Application CIS N, Designed to ensure positive shut-off and long maintenance-free . U� service life in liquid or vapor service.Ideally suited for use on cylinder charging manifolds, truck filling hoses, bulk storage containers and plant piping. The high quality construction and wide variety of sizes make them Open highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. Features • Available with either a brass bonnet and bronze stem for LP-Gas service or a steel bonnet and stainless steel stem for combined LP-Gas and anhydrous ammonia service. 1 311/16" • Flange seal stem provides for leak-proof operation.No packing to 77 0 P reti hten or replace. A7 P 9 p 7705 P A7705 P • Metal-to-metal back seat permits replacement of the flange ring with the valve in service. • Plugged '/4" NPT boss on downstream side of valve A7704P accommodates hydrostatic relief valve or vent valve. • Swivel seat disc minimizes grinding on the body seat and ensures longer service life. • "Dropped seat'body design of the angle valve provides high flow capacity. 33/1fi Open Materials Body............................................................................... Ductile Iron Bonnet(7704,05,06).............................................................. Brass _ Bonnet(A7704,05,06)............................................................ Steel _ Stem(7704-05-06)................................................................ Bronze Stem(A7704-05-06).................................................. Stainless Steel Flange Ring........................................................... Synthetic Rubber Seat Disc............................................................... Synthetic Rubber 111/s" 7704 LP A7704 LP 7706 P A7706 P 7706 P 'Irdering Intornm- IPart Number Accessories 16L Angle Inlet&Outlet Connection(E NPTkwm Hydrostatic Relief Valve Vent Valve 7704P 7704LP A7704P A7704LP Y� 7.3 12.3 7705P 7706P SS8001 J or SS8001 L TSS3169 A7705P A7706P a/ 11.5 17.7 To obtain approximate flow at other than 1 PSIG pressure drop,multiply flow in table by square root of pressure drop.Example:A7704 LP @ 9 PSIG=12.3 x f=36.9 GPM/propane.For NH3 flow, multiply propane flow by.90. EIG AMMM 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com +1(336)449-7707 General Information RegO Back Pressure Check Valves are designed to allow flow in one Metal-to-metal seats will allow slight leakage after closure. These direction only. The check, normally held in the closed position by a valves will restrict the escape of container contents in the event of spring, precludes the possibility of flow out of the container. When accidental breakage of the piping or fittings. flow starts into the container, the pressure overcomes the force of the spring to open the check. When the flow stops or reverses, the check closes. Back Pressure Valves for Container or Line Applications Application Designed to provide protection of a container opening when desired flow is always into the vessel.May be used in line applications where flow must be limited to one direction. —A When used with the appropriate single check filler valve, the combination forms a double check filler valve suitable for use in filling ° of bulk storage tanks. c Features B • Generous flow channels for low pressure drop. • Heavy-duty construction for long service life. 3146Series,31765eries,A3186,A3196 • Soft seat valves have synthetic rubber seat disc for positive seals. 11 Materiais Body(3146,3146S,3176)....................................................... Brass Body(all others) ........................................... Cadmium Plated Steel A Disc(3146,3146S,3176)........................................................ Brass Disc(all others)............................................. Cadmium Plated Steel Stem(3146,3146S,3176) ...................................................... Brass Stem(A3146,A3196,A3276BC) .............................. Stainless Steel ° Stem(A3176,A3186) Cadmium Plated Steel c ................................... Spring ..... ........................... .................................... Stainless Steel B Seat Disc 3146S,A3276BC ............................... Synthetic Rubber ( A3276BC —Effective Length REGO 1 O (2"-11.5 NPTF THD) (2"-11.5 NPTF THD)YEAR WARRANT (3"-8 NPTF HD) 8.209 A3198S A3187S Container Service Installation Typical Installation 3146,A3146,3146S,3147S,A3276BC,3176,A3176,A3186,A3196 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com +1(336)449-7707 MEL F29 ' . •I. Application Designed especially to provide pull-away protection for LP-Gas and p� anhydrous ammonia transfer operations including transport and �- delivery truck loading and unloading,engine fuel container filling and miscellaneous cylinder filling operations. When properly fastened to ( r the inlet end of the discharge hose,the valve is designed to stop gas escape from both upstream and downstream lines in the event of a pull-away.An excessive tension pull causes the valve to automatically separate,closing two internal back pressure checks.Only a few cubic centimeters of gas escape at the instant of separation. A2141AG It is recommended that a convenient means be provided to safely remove the pressure from the line upstream of each coupling half to enable reassembly of the valve.To reassemble,simply push the male half firmly into the female half until the retaining balls slip into the retaining groove.Check for leaks after reassembly. NOTE: It is recommended that pull-away valves be maintained and -- safety tested perodically to confirm that they will separate properly in the event of a pull-away. Lubrication every six months is essential to the pull-away's operation.Dry nitrogen or other inert gas is suggested as a source of pressure for pull-away tests. If the A2141 pull-away valve is going to be stored for a period of time, A2141 Series such as in seasonal applications, it is recommended that it be sprayed with a good grade of rust-preventive machine oil, A214UUO and covered to protect it from moisture. Features • Heavy-duty construction for long service life. • A"true"pull-away type valve which simply reconnects by snapping together without unnecessary downtime or need for new parts. • Buna-N seals provide leak tight operation. n s A e • 400 PSIG operating pressure. Materials Body(%" 1")................................................. Cadmium Plated Steel Body(1%",2")............................................... Cadmium Plated Steel Seals........................................................................ Buna-N Rubber A2141A6 A2141A6L Cables........................................... Nylon Coated,Galvanized Steel A2141A8 A2141A8L 8.5"Appro 12.3" 5" 5.51" REG YEAR WARRANTY A2141A16 A2141A10 Orderi) . Differential Part Number Connections Force Force Length Of Valve A2141A6 130 80 3'/a" 11 16 25 36 A2141A6L** A2141A8 1" 75 50 4%6" 21 30 47 67 A2141A8L— A2141A10 1'/<" 160 25 5%11 52 75 120 170 A2141A16 2" 300 50 149/16 250 350 550 750 *To Determine NH,Iiq.,d flow capacity,m tlply by.W 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com +1(336)449-7707 SEGO .I Application o05 Designed especially for the protection of piping and shut-off valves . U� where there is a possibility of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and hoses located 3129-10 between shut-off valves or in the side boss of RegO shut-off valves. Pipe Aw Features • Relief valve designed to automatically reseat firmly after discharge. • Resilient seat disc provides a"bubble-tight"seal. J04 I • Available in both brass and stainless steel. • Available in configurations that permit direct attachment of vent piping when required. C Materials Body(3125,3127,3129)........................................................ Brass Body(SS8001,SS8002,SS8021,SS8022)............. Stainless Steel A Spring....................................................................... Stainless Steel Seat Disc............................................................... Resilient Rubber 3125 Series(.161 Orifice) 3127 Series(.274 Orifice) 3129 Series(.386 Orifice) Ordering Information ConnectionStart To Container ILe ch Pipeaway- SS8001 G /<" 11/16" SS8002G Stainless /2' /s W, SS8021G Steel /4" , 11/16" /4"NPSM Thrds SS8022G 250 '/2' 1/8' /a 3/d'NPT Thrds 3127G '/4" 131/32' 9103-54 3129G '/2' 219/32" 1'/d' 3129-40P 3129-10* 3127H 275 Brass %1' 131/32, 3/8" 9103-54 - 3124 /2' 219/32' 1%11 3129-40P 3129-10* 3127P /4" 131/32" 1'/a" 9103-54 - SS8022G 3129P 300 219/32" 1%11 3129-40P 3129-10* SS8022P Stainless /2' 1%11 %a" - 3/a"NPTThrds Steel 7K 3127J Brass 1/a" 131/32" %a" 9103-54 - C C 3129J '/2' 219/32" 1%11 3129-40P 3129-10* SS8001J 350 '/4" 1W, 11/16" - SS8002J Stainless '/2' %a" SS8021J Steel 1/4' 11/16" WNPSM Thrds SS8022J /2' 13� WNPT Thrds A 3127K '/4" 131/32" /a 9103-54 - 3129K 375 /2" 219/32' 11/8" 3129-40P 3129-10* A SS8001,SS8002 3125L Brass 19/16" %' 3125-40P Series 3127L /" 131/32' 9103-54 SS8021,SS8022 (.156 Orifice) *2 /32" 1%11 3129-40P 3129-10 Series 3129E '/2' 19 (.156 Orifice) SS8001 L 400 '/4" %11 11/16" SS8002L Stainless '/2' %d' SS8021L Steel '/4" 11/16" 1 '/d'NPSM Thrds SS8022L ''/z" W NPT Thrds _ 3127U Brass /°' 131/32" /a 9103-54 - R E G 3129U '/2' Z19/32' 111/16" 16" 3129-40P 3129-10* O SS8001U 450 �/4 /1s SS8002U Stainless '/2' SS8021U Steel '/;' 1„ 11/16" /4'"NPSM Thrds YEAR SS8022U '/2' %a" 3/2'NPT Thrds r WARRANTYdi *1/2'F.NPT outlet connection. DIG SEGO 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com +1(336)449-7707 Application 7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop driers. They are also ideal for charging manifold hoses,stationary fuel transfer hoses and other applications requiring quick,positive shut-off.They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as the hose is reeled back to the truck. 7554L Series valves feature a locking handle device to help prevent accidental opening of the valve.It is ideal for all the same applications as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design. Both valve series must be installed so that flow through the valve is opposite to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve and prevents the valve from being opened by high pump pressures. 311" Features 7554S 3• • Quick-acting design speeds transfer operations, permitting rapid, one-handed opening and closing. • Resilient seat disc provides positive shut-off. 3 i16 • Flange seal stem design provides for leak-proof operation. No packing to retighten or replace. • 7554L Series incorporates locking handle to prevent accidental opening of the valve. INLET • Vent valve installed on the downstream side of the valve permits bleeding of trapped product to ensure safe uncoupling. • Swivel seat disc minimizes grinding on the body seat and ensures s longer service life. Materials Body................................................................................ Ductile Iron Bonnet...................................................................................... Brass StemSeal................................................................................ Teflon Stem.......................................................................... Stainless Steel Seat Disc................................................................ Nitrile Elastomer 3• Seal Housing..............................................................................Brass Lever...........................................................................................Brass 7594LV 3 116' INLET 127, 31118 Ordering Information Part Number Inlet&• .. ... 7554SAV No 7554LAV �z Yes 7.3 7554SV No 7554LV Yes 11.3 *To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in table by square root of pressure drop.Example:7554LV @ 9 PSIG=11.5 X✓9=34.5 GPM/ propane. $$ fiVAEGQ 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com +1(336)449-7707 - I I Application Designed especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off,encouraging cautious removal to properly A bleed off trapped product to ensure closure of the filler valve and hose end valve.The ACME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle,providing for durability under repeated use. Features • Lightweight aluminum handle is contoured and ribbed for added C comfort,easy handling allows for easy make-up. • Free swivel action between tailpiece and handle allows for easy 5" make-up. • Simplified design eliminates an extra joint and provides smooth, uninterrupted flow. sb B A7571Series For Vapor Equalizing Materials Handle............................................................................. Aluminium ACME Threads................................................................. Steel Inlet Restraining Ring....................................................... Stainless Steel A— I I RE y C ! 5" )1 I B A7575Series For Liquid Filling Ordering Information Part Type Hose Connection Coupling Connection ,11M of Service (M.NPT) W ACME) Length A75751_2* 1/2" A75751_3 3/a" A7575L4 Liquid ill 1'/a" A7575L5** 11/<" 7 A7571 LA /2" 1 A7571 LB Vapor 3/„ Includes 7199-33 adapter,shipped loose. Includes A75751-5-1 adapter,shipped loose. H4 M9992 100 Rego Dr.Elon,NC 27244 USA www.regoproducts.com Phone(336)449-7707 SMITH ; PUMPS Small Capacity Pumps EC-HZ Pump E-Series Each E-series pump comes complete with an internal/external bypass valve and built-in strainer. Affords the flexibility of either using the pump bypass valve to relieve within the pump in cases where it is necessary or with a simple rotation of the pump cover,the internal bypass valve can be used as an external bypass valve with the use of a return line back to the supply tank.The bypass valve cartridge is set to crack at 90 psid. Designed for direct motor mount to the 56C-frame electric motor or to internal combustion engine for portable transfer applica- tions. Replacement parts for E-series are Interchangeable with D-Series. Foot mount available. Pump Specifications PumpOnly Average Deliver Rate Internal Bypass Maximum Differential Inlet/Outlet Size Motor y g y Relief Valve Setting Pressure Female Threaded Pump Rotation Looking at Pump Model 40 PSID, 75 PSID,3600 RPM 3600 RPM PSI PSI Inches HP Shaft End EG-1Z 81/2 7 90 125 3/4 1 CW EC-HZ 131/2 1 12 90 125 1 11/2 CW GEAR SET EASY TO MAINTAIN BALANCED GEAR CONFIGURATION Without disturbing the mechanical shaft Minimizes gear tooth contact and eliminates constant seal,the gear set can easily be replaced. casing contact.Allows for higher differential pressure. All pipework remains in place. SUPERSEAL MECHANICAL SHAFT SEAL ASSEMBLY Built as a kit onto the pump shaft - Your assurance that the seal has been tested before and after assem- bly into the pump. All replacement mechanical shaft CONVERSION TO LARGER CAPACITY PUMP seal assemblies are dynamically liquid tested before With the addition of 1-3 secondary gear shipment. housings, each with 50 GPM capacity, bulk transfer pumps can easily be converted to higher capacity. - r NO SERVICE BALL BEARING With no load design, permits the use of radial contact ball bearing,requiring no periodic greas- ing or servicing of any kind. CARBON GRAPHITE JOURNAL BEARINGS Designed to withstand vapor conditions associated with liquefied gases and support the entire length of the pump shaft to maximize smooth,efficient operation. State-of-the-art Mechanical Shaft Assembly Smith Precision Products Company offers a full line of positive displacement pumps for liquefied gas transfer. Designed for safety and high performance, Smith pumps are unequalled in installations ranging from small capacity cylinder filling to large capacity bulk loading or unloading facilities. Smith Precision Products Company has been designing and manufacturing liquefied gas pumps since 1938 and has Introduced many innovative designs now standard on most liquefied gas pumps. Positive Displacement Gear Design lends to highest efficiency. Smith pumps utilize a high efficiency gear set designed for high performance, minimal slippage, and ease of maintenance. The unique design al- lows for balanced internal loading which greatly increases pump life expectancy. Smith pumps are widely used for applications including cylinder filling, automotive fueling, bulk transfer, vaporizers, high pressure burners and truck applications. Standard base type models are available In 3/4, 1, 1-1/2, 2-1/2, and 4-inch port sizes. Options include threaded housing ports or threaded and/ or weld flanges. Smith pumps utilize a 3-piece mechanical shaft seal designed as an integral part of the pump shaft. This unique feature allows the actual seal ring to rotate at 1/2 the shaft speed, greatly increasing seal life. Also, should mechanical seal replacement ever be necessary In the field, service personnel won't be fumbling around with loose seal components.The Smith mechanical seal is received as a factory tested, assem- bled unit that cannot be taken apart. Additionally, all Smith pumps include an ease of maintenance design that allows the gear set to be replaced WITHOUT Taking the mechanical shaft seal apart. ALL PUMPS AND BYPASS RELIEF VALVES shown are listed with the Underwriters Laboratories and are manufactured and tested to UL-51. Solutions be vnd products... CORKEN- ASEX Coro-Flo® Pumps The Coro-Fio® pump is offered in three different model drive configurations. The C-Model configuration has the pump close coupled to a motor (shown below). The F-Model has a separate pump body and is directly driven through a coupling. And finally, the DS/DL Model pumps are mounted on a special bracket which will accept standard C-face motors. Designed specifically for LPG, the C-Model pump is extremely quiet and free of vibration and pulsation and provides trouble free service and long life for volatile liquids such as LPG. The one W 4o, s moving part, the impeller, floats on the shaft without contact- 3 • ing adjacent surfaces, thus extending pump life. All Coro-Fio® pumps are listed by Underwriters Laboratories, Inc. for LP-Gas i and anhydrous ammonia service. XAW �l -�� The F Model pump is the base plate mounted version. Coro-Flog pumps are designed to operate at shaft speeds between 2880-3600 rpm. The F-Model provides the flexibility of motor selection. l The DS/DL Model pumps are designed to eliminate the need for a baseplate, coupling guard, and coupling alignment which . VENOM makes DS/DL series pumps compact and easy to install. The special bracket supports both the pump and the motor so they t can be directly coupled. .� Now Additional Mounting Holes Coro-Fio® pumps have an option of ANSI flange connections on all of the various sizes and model types. • 1 11 Section: 501 Part of Pump Solutions Group® Effective: October 2012 DDYBt c wn Replaces: February 2009 LG1 Series Sliding Vane Pumps for Cylinder Filling ro�O LGF1 E and LGF1 PE model sa h Cylinder Filling How Blackmer's sliding vane action works LGB1 E and LGB1 PE model Reliability Flow Rates Durable pumps for fast and quiet operation.Sliding vane At motor speed 1,750,the LG1 Series pumps provide design provides sustained performance and trouble approximately 8.0 gpm (30.3 L/min)at 50 psi (3.4 bar) free operation. and the LG1 P models provide 13 gpm (49.2 L/min)at 50 psi (3.4 bar). Unique Features The latest 6-vane design contributes to reduced noise levels Applications in the pumps.All models have 1-in. NPT tapped parts and Cylinder filling,motor fueling,small vaporizers use an exclusive"combination"valve that acts as both a and dispensers. back-to-tank bypass valve and an internal safety valve (no separate bypass valve is needed).The LGF1 pumps accept standard C-face mounted motors. �► LG1 Series Sliding Vane Pumps for Cylinder Filling AA E $ "B'KEY AA E S S Ir U V � D �E U V U "B"KEY "B"KEY o 0 4 Q A M A� M o 0 Q A o G K F%� K I� *LGF Model non-footed **LGF Model footed LGB Model Dimensions Pump Model A B r r Approximate.Wt. lbs. k *LGF1 E in. 11/16 3/16 311/16 41/2 - - - 71/8 41/2 21/2 21/2 611/16 LGFIPE CFaceMount mm - - 93.7 114.3 - - - 181.0 114.3 63.5 63.5 169.9 39 17.7 **LGF1 E in. 11/16 3/16 311/16 41/2 31/8 65/8 41/2 85/16 41/2 21/2 21/2 611/16 LGF1 PE C Face Mount mm - - 93.7 114.3 98.4 168.3 114.3 211.1 114.3 63.5 63.5 169.9 39 17 7 LGB1E Bracket in. 1 11/16 1 3/16 1311/16 141/2 1 29/16 1 31/8 131/2 1 7s/1e 1 41/: 1 21/2 21/2 - 19 8.6 LGBIPE Mount mm - - 93.7 1 114.3 1 65.1 1 85.7 1 88.9 1 185.7 1 114.3 1 63.5 63.5 - Performance Data Pump and Approx.Approx.Delivery of rr. Diff Maximum Maximum Typical rr r Assembled Motor r r r Motor r. r Speed 1 psi r. 00 psi bar) Pressure Pressure Model I RV Setting (rpm)' gpm L/min gpm L/min psi bar psi bar hp Minimum Frame Maximum Frame LGHE 105psi 1,750 8.0 30.3 6.0 22.7 125 8.6 350 24.1 1 56C 184C4 (7.2 bar) LGB1 E-DM 105 psi 1,750 8.0 30.3 6.0 22.7 125 8.6 350 24.1 1 56 184 (7.2 bar) LGF1 PE 120 psi 1,750 13.0 49.2 10.0 37.9 125 8.6 350 24.1 1.5 56C 184C4 (8.3 bar) LGB1PE-DM 120psi 1,750 13.0 49.2 10.0 37.9 125 8.6 350 24.1 1.5 56 184 (8.3 bar) 1 Maximum pump speed is 1,750 rpm.Slower electric motor speeds may be used with a corresponding reduction in flow rate. 2 Maximum rated working pressure is 350 psi(24.1 bar)for LPG and NH,(limited by U.L.and N.H.A.58). 3 Motors may be specified from dimension charts above and electric motor price list No.10-MTRG-01(explosion proof manual start switch for 1 and 11/2 horsepower single phase motors also available). 4 Pump flange accepts NEMA C-face motors with 5 7/8"bolt circle diameter.Pump flange will not accept 182TC or 184TC frames. Combination Relief/Bypass Valve Normal Operation Back-to-Tank Bypassing Pressure Relief Valve is completely Discharge pressure If back-to-tank line closed during normal exceeding the valve is closed,valve O operation with O settings opens valve to O opens to third stage, discharge line open. second stage,returning passing flow back to all or part of pump flow inlet side of pump. back to supply tank. OEIPGA Part of Pump Solutions Group® • DDVER m �' Process Energy I Military&Marine World Headquarters �SG 1809 Century Avenue SW,Grand Rapids,MI 49503-1530 USA PUMP 50LUTIONS GROUP T616.241.1611 F616.241.3752 www.blackmer.com Printed in USA O 2012 Blackmer • DDVER�co.wxr OPERATING } PERMIT APPLICATION Department of Community& Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Part I Applicant/Building Information Applicant's Name: Air Gas Arlington Applicant's Address:5925 199th St NE, Arlington, WA 98223 Contact Person:Kelly Kite Telephone:253-380-0286 Address of Premises for which Operating Permit is requested: © Same as above ❑ Other(specify): Tax Parcel ID#: 00746300000100 Current Occupancy Class:General Industrial Part II Type of Operating Permit An Operating Permit is required to conduct any activity or to use any class of building listed below.Please indicate the type(s) of Operating Permit(s)requested by checking each applicable box. (If you require assistance, or would like more information,contact the City of Arlington Building Department at 360-403- 3551.) ❑ Manufacturing,storing or handling hazardous materials in quantities exceeding those listed in the Fire Code (see Appendix A.)Identify the materials and quantities and describe the manner in which the materials will be manufactured, stored or handled(attach additional sheets if necessary): Revised 4/l/08 Received Page 1 of 4 JUL 2 8 2023 r515 Part H (cont'd) ❑ Conducting a hazardous process or activity, including, but not limited to, any commercial or industrial operation which produces combustible dust as a byproduct,fruit and crop ripening,waste handling, spray operations, and high-piled storage (see Appendix B.) Describe the process(es)or activity(ies)to be conducted (attach additional sheets if necessary): ❑Use of pyrotechnic devices in assembly occupancies (see Appendix C.)Describe the devices to be used and type of event(attach additional sheets if necessary): 21 Aboveground Storage Tank(AST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanent tank closure Brief description: installing a 1000 gallon propane dispensing unit ❑ Underground Storage Tank (UST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑Temporary Membrane Structures, including tents and canopies (see Appendix E.)Brief description of structure and use: Cc: Fire Department Page 2 of 4 Part II (cont'd) ❑ Special Event Operating Permit -An Operating Permit is required for any special event that takes place within an occupied building, or an outdoor mass gathering,which is outside the scope of the permitted use (see Appendix F.) Brief description of type of gathering proposed: Part III Premises/Building Information 1. Date of last inspection of Premises: 2. Has a Certificate of Occupancy been issued for the premises?© Yes ❑No Type: ©Permanent ❑ Temporary Date of Issuance: 3. Are there currently any open Building Permits associated with the premises? 0 Yes ❑ No Permit #: 5424 If yes,please describe(attach additional sheets'if necessary):' - 4. Additional Comments: SIGNATURE OF APPLICANT I herby certify that the foregoing information(and all information in attached sheets, if any) is true and complete. 07-28-2023 luakft or Authorized Representatives Signature Date Kelly Kite Name and Title (if applicable) of person signing Application (Please print) Cc: Fire Department Page 3 of 4 Part IV To be completed by the City of Arlington Building Department Inspection Required: M`YYes ❑ No Inspections Performed: ❑ Yes No Date of Inspection: Tests or Reports required verifying compliance? ❑ Yes No If YES, have Tests or Reports been received? ❑ Yes ❑No Application(s) Approved: ElYes ❑ No Operating Permit Issued by: Cky Date Operating Permit Issued: Date Operating Permit Expires: ' Type/Description of Operating Permit: fo:LP NEE- �7L5p�J5L-iZ , Conditions of Operating Permit(list conditions here AND in the space provided in the Operating Permit): IWlL6 U11?c' 13c�(.L►��Z'p Pt2dCC� �o[.1 ac�; Lt_1Zt75 �c 96- pZ-kc-, no 4 1-dl l co cEP yeh—z— Kme 3!oft Ki sl zp)�rwp� <c> f3G w5l- sz-" D 1*,1 l 5 t� K%tJ PIA., VkOLLs Additional Comments: (Attach additional pages if needed) _ G►4 _�Co1JGQ+ � MUS'� �� M�+r�1 3L�t Cc: Fire Department Page 4 of 4 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com Comment Letter on Permit 5512/5513 August 9, 2023 Jeff Lincoln Air Gas USA LLC 5925 199th St NE Arlington, Wa. 98223 Hello, I am reviewing your permits for a propane tank and dispenser at the Air Gas facility. I came down and I was told there was previously a dispenser. I just need to make sure the dispenser and tank comply with the Fire Code. As you are in the business, I am sure you are aware of the distances, I just need to verify. I have the sketch and the table on the following pages. I also need to know what type of impact protection there will be for the tank. The area is pretty tight as you come in and the tank/dispenser will create more congestion. I have a spec on bollards if you need them. • Weeds, grass, brush, trash and other combustibles shall be not less than 10 feet away from the LP-gas tanks or containers. • The other gases in storage use would need to be 25 feet away from the filling area. On the day I was there I was not sure you had the distances • Each industrial plant, and distributing point shall be provided with at least one portable fire extinguisher in accordance with Section 4.7 having a minimum capacity of 18 Ibs with a B:C rating within 30 feet • No smoking signs within 25 ft of filling station 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com 30.000 GALLONS EACH UNDERGROUND S,000 GALLONS SO•-0'MINIMUM MINDALAM —5'-0'MINIMLAM STREET 25'-0-MINIMUM i i ® i -No GALLONS ' BUILDWO Y-WMINIMUMJ ® -•---•-.- 10'4r 2S'0' � BUILOfJG7-25-4r 1.000 GALLONS 4. Ply 000 GALLONS EACH �I NOTE:ALL LPG CYUINOERS.ALL ABOVE GROUND EXCEPT WHERE NOTED_ 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com y RL 1116TON a Al VZc,A-s Ulg R E H0145 E 0 Fe,ce - l 1 _ AAQJ. S� of /t{Dg..c rMk C,ATJE I I �1 uo �o c� } Q This is the table I am working from 8117 267th Street NW Stanwood,WA 98292 North County Regional Fire Authority Phone:(360)629-2184 ` •, Fax(360)652-3166 www.northcountyfireems.com TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS MINIMUM SEPARATION BETWEEN LP-GAS CONTAINERS AND BUILDINGS,PUBLIC WAYS9 OR LOT LINES OF ADJOINING PROPERTY THAT LP-GAS CONTAINER CAPACITY CAN BE BUILT ON MINIMUM SEPARATION BETWEEN LP-GAS CONTAINERS'c (water gallons) Mounded or underground Above-ground LP-gas containersb (fit) LP-gas containers' (feet) (feet) Less than 125`d 10 5e None 125 to 250 10 10 None 251 to 500 10 10 3 501 to 2,000 10 25'1 3 2.001 to 30.000 50 50 5 30,001 to 70.000 50 75 70,001 to 90.000 50 100 (0,25 of sum of diameters of adjacent LP-gas containers) 90,001 to 120.000 50 125 For SI 1 fat=3048 min 191111n=3785L a.Minimum distance for underground LPgas containers shall 4 measured hom the pressure relief device and Me filling or Ipad-level gauge vrnl connection at the container.except Mat all parts of an undegound LPgas cmtainer shall be nbt kss than 10 feet from a building or lot In,of atioining abcedy Mal can be buin on b.For MM1er Man installations in rMicM1 the osreManging strvdure rs SO feel or more above Me relief-valve discharge w0et.In applying Me tlistance behveen buildings ant ASME LPgas containers wiM a wafer capacty o1125 gallms or more.not less Man 50 percent of Mis M1ori_ontal distance shall also apply to all podinns of Me WIdbg Mat pr 1more Man 5feet from Me bmldmgwall and that are higher than Merelief valve discharge bullet This ho,cbntal distance shall be measured from a point del—alb by pbbding Me outside edge o1 such overhanging structure vbin-Hy damvrad ro grate a other I...I on which Me LP-gas container is installed Distances to Me Wilding wall sM1all be not—than Mole p—bet in th5 table c._underground multiconlainer installations an,—p—a.1h.�itlual LPgas containers daring awaler c-ty of 125 gallons in more.such containers shall beinstalled so asto Ina—access at their entlsasides to faubale v:o st—cranes a hoists d.Ataconsumer stle if Me aggregate watercapacily ofa multiple.obtainerinslarabbn comprised of individual LP-gas containers raving.water -tybfless than 125 gallons.,500 gallons or more.Me minimum distance shall cbmpl,vnlh the appropriate poNm Ott"table applying the aggregate ceDacitY ranter Than Me capadty per LP-gas container If more Than one such installation is made each inslallalim shall W sepa,alet from olds indallafims by nd less Man 25 n-Minimum distances behreen LPgaz containers need nM be applie0 e.Tlie follovdng shall apply to aboveground cl ntai,rtrs installed alorgsitle b.b iN, 1.LPgas containers o1 kss Man a 125ga11mwafer capacity are all—wiM a separation tlislanm wherein ca.pliancew nth Items 23 and 4. 2.Depadmrnt of Transpbdation IDOTni specification LPgas containers shall De located and installed w that the discharge hom the container a—Iin,bt,f device Is not kss than 3 feet horizontalry bbbi buiking oprnngs bdov:the level of—discharge and shall nd ce'meant buikings unless the space is well v..blatetl to In,outside and It not enclosed for more Man 50 percent of ifs perimeter Th,discharge from LP-gas container aessure relief devices shall be locaret nor less Man 5 feel from eAedor sources of ignition openings into tired-vent lsealet omb-bi,syslemi al%rbances a mechanical ventilabm air Intakes 3.ASME IPgaz-tamers of—than a 125yallon ware,c,p,,ty shall beocated l and Installed such that the discharge tram essu prre,tlief d,,,a shall not tmminate In or beneah buik—till, and shall be located not less Man 5 f or�on fiat hrally from baiting openings W=the Iesal of sucM1 tiuhargecand not less Man 5 feel ham eAedor sources of ignition.openings into direct vent isealetl combustion syslemi appliances.or mechanical—hahb,air intakes. 4.The filling connection and Me vent from liquid-level gauges on either DOT.or ASME LPgas containers filled at Me point of installation shall W not less Man 10 1-1 from ededa swrtes b1 ignition openings into direct vent IsealM canWstion syslemi appliances or mechanical ve b abbe air intakes f.TNs tistance is aIt.-tb be r...d to not less Man 10—Ior a single LPgas cmtainer M 1200-garon water capacity or less.provitet that such container is not less than 25 feet I——LPgas containers of more than 125-galkn v,ah,.capacily. g.Aboveground LPgas containers th av:a capacily o12 OOD gallons or less stall be separated hom hbI.ways by a distance of not less M an 5 leer Containers—awaler capacity It,—,Man 2000 gallons stallbe separated flan pudic ways in—dance vah thistable. Steve Goforth,Assistant Chief/Community Risk Reduction North County Regional Fire Authority 8117 267111 St NW Stanwood,WA 98292 Office 360-629-2184 x105 Cell 360-502-6184 sgoforth@northcountyfireems.com "Serving our Communities with Compassion" Serving the Cities of Arlington and Stanwood,the rural communities of Bryant,Freeborn,Warm Beach, Kayak Point and the Stillaguamish Tribe of Indians. CONFIDENTIALITY NOTICE This e-mail message,including any attachments,is for the sole use of the intended reciplent(s)and may contain confidential,proprietary,and/or privileged information protected by law. If you are not the intended recipient,you may not use,copy,or distribute this e-mail message or its attachments. If you believe you have received this e-mail message in error,please contact the sender by reply e-mail and telephone immediately and destroy all copies of the original message.Thank you Permit#: 5513 Permit Date: 07/31/23 Permit Type: OPERATING Project Name: Air Gas USA LLC Applicant Name: Propane Northwest Applicant Address: 1906 Marc Ave Applicant, City, State, Zip: Tacoma,WA 98421 Contact: Kelly Kite Phone: 253-875-3000 Email: kellykite@thompsongas.com Scope of Work: Install new 1000 gallon propane tank with dispenser equipment Valuation: 15000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 01/27/2024 Form Permit Type: OPERATING Status: EXPIRED Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning AIRGAS-NOR 910 00746300001600 199TH ST NE UNDEVELOPED PAC INC (VACANT)LAND Plan Reviews Date Review Type Description Assigned To Review Status 07/31/2023 OPERATING BUILDING In Review 07/31/2023 OPERATING New 1000 gal tank FIRE Pending Corrections Fees Fee Description Notes Amount Processing/Technology $25.00 Total $25.00 Notes Date Note Created By: 07/31/2023 The property where the tank is to be installed does not have an address.The address provided on Kristin Foster the application is for the Airgas office parcel. Uploaded Files Date File Name 07/31/2023 16347165-20230728 BLD5513 SitePlan.pdf 07/31/2023 16347060-20230728 BLD5513 App.pdf 07/31/2023 16347061-20230728 BLD5513 Specs.PDF