HomeMy WebLinkAbout18825 67th Ave Ne_BLD5514_2026 SYSTEM RECORD OF COMPLETION Form Completion Date:09/29/2023 Supplemental Pages Attached:01 1. PROPERTY INFORMATION Name of property: Mid Mountain Materials Address: 18825 67th Ave NE Arlington,WA.98223 Description of property: manufacturing Name of property representative: Fred Willcutt Address: 18825 67th Ave NE Arlington,WA.98223 Phone: 360-454-0009 Fax: 360-435-4192 E-mail: faw(cDmid-mountain.com 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor:ADT Commercial Address: 600 Oakesdale Ave SE Renton,WA.98057 Phone: Fax: E-mail: Service organization:ADT Commercial Address: 600 Oakesdale Ave SE Renton,WA.98057 Phone: 800-357-1808 Fax: E-mail: Testing organization: ADT Commercial Address: 600 Oakesdale Ave SE Renton WA.98057 Phone: 800-357-1808 Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: ADT Commercial Address: Phone: 800-357-1808 Fax: E-mail: Account number: STI-0017993 Phone line 1: Phone line 2: Means of transmission: Cellular Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION Document Box On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system 0 Modification to existing system Permit number: 4163 NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: Resideo Model number: Vista 128FBPT 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification 0 This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds NFPA 72(p.1 of 3) n� 0 2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized HFFW use,contact licensing@nfpa.org. SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120vac Control panel amps: 20 Overcurrent protection: Type: breaker Amps: 20 Branch circuit disconnecting means location: South Lab Number: HNL#AES Br#12 5.1.2 Secondary Power Type of secondary power:sealed lead acid battery Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): 24 In alarm mode(minutes): 5 5.2 Control Unit 0 This system does not have power extender panels OO Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line B Device Power Initiating Device B Notification Appliance B Other(specify): 7. REMOTE ANNUNCIATORS Type Location Resideo 6160CR-2 West WHSE Entry 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Conventional Alarm Manual Smoke Detectors 1 Conventional Alarm Smoke Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches 2 Addressable Alarm Flow Tamper Switches 4 Addressable Supervisory Manual NFPA 72(p.2 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use,contact licensing@nfpa.org. SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 1 Bell Visible 16 System Sensor Strobe Combination Audible and Visible 19 System Sensor Horn/Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS 0 This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Greg Bjornerud Printed name: Grea Biornerud Date: 12/14/2022 Organization:ADT Commercial Title: Foreman Phone: 206-423-2167 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Randy Chenard Printed name: Randy Chenard Date: 03/09/2023 Organization:ADT Commercial Title: Service Technician Phone: 206-255-5256 12.3 Acceptance Test Date and time of acceptance test:03/16/2023 Installing contractor representative: Randy Chenard Testing contractor representative: Randy Chenard Property representative: Fred Willcutt AHJ representative: NFPA 72(p.3 of 3) n ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale �.m•, or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized NFEW use,contact licensing@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION Form Completion Date: _ Number of Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property:Alid-Mo m ain Materials_ Add yetis-_jaU5uZJkiA E AsiAotonJb'l�_98223 2. SYSTEM POWER 2.1 Control Unit 2.1.1 Primary Power Input voltage of control panel: 120vac Control panel amps: 20 Overcurrent protection: Type: Breaker Amps: gn Location(of primary supply panelboard): smith i nh Disconnecting means location: PNL#AES Br#12 2.1.2 Engine-Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.1.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.1.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): 2.2 In-Building Fire Emergency Voice Alarm Communications System or Mass Notification System 2.2.1 Primary Power Input voltage of EVACS or MNS panel: EVACS or MNS panel amps: Overcurrent protection: Type: Amps: Location(of primary supply panelboard): Disconnecting means location: NFPA 72(p.1 of 3) 2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use,contact licensing@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) 2. SYSTEM POWER (continued) 2.2.2 Engine-Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.2.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.2.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculaaed capacity of batteries to drive the system: — In standby mode(hours): In alarm mode(minutes): 2.3 Notification Appliance Power Extender Panels ❑This system does not have power extender panels. 2.3.1 Primary Power Input voltage of power extender panel(s): 120vac Power extender panel amps: 20 Overcurrent protection: Type: Breaker Amps: 20 Location(of primary supply panelboard): South Lab Disconnecting means location: PNL#AES Br#12 2.3.2 Engine Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.3.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.3.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): NFPA 72(p.2 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized NFPA use,contact licensing@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) 2. SYSTEM POWER (continued) 2.4 Supervising Station Transmission Equipment [ This system does not use transmission equipment within the building powered by any other source than the alarm system control unit. 2.4.1 Primary Power Input voltage of shared transmission equipment: Shared transmission equipment panel amps: Overcurrent protection: Type: Amps: Location(of primary supply panelboard): Disconnecting means location: - 2.4.2 Engine Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.4.3 Uninterruptible Power System Equipment powered by UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.4.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): See Main System Record of Completion for additional information,certifications,and approvals. NFPA 72(p.3 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale L� or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized use,contact licensing@nfpa.org. FIRE ALARM LEGEND & MATERIAL LIST SYMBOL DESCRIPTION MANUFACTURER PART NUMBER CITY. 1 U FF—AC—Pl FIRE ALARM CONTROL PANEL HONEYWELL VISTA V128FBPT EXIST MID MOUNTAIN MATERIALS °J FA—NN-1 FIRE ALARM REMOTE ANNUNCIATOR HONEYWELL 6160CR-2 EXIST SCOPE OF WORK: ADD NOTIFICATION TO WAREHOUSE 18825 67th AVE CELL FIRE CELLULAR COMMUNICATOR NAPCO SLE-LTEV-FIRE EXIST 1 1. THIS IS AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM INSTALLED 7/2021. NAC NAC BOOSTER POWER SUPPLY FIRELITE FCPS-24FS8 1 NEW FOR THIS 2023 UPDATE THE FIRE MARSHAL WANTS NOTIFICATION ADDED INSIDE w THE WAREHOUSE AREA AS SHOWN. >u DOC FIRE DOCUMENTS CABINET MIERPRODUCTS BW-DOCBOX EXIST A R L I N G T O N, WA 98223 2. INSTALL NEW NOTIFICATION BOOSTER POWER SUPPLY(NAC#2 PANEL)UPSTAIRS m o E MANUAL PULL STATION(CONVENTIONAL) FIRELITE BG-12 EXIST IN IT CLOSET NEXT TO EXISTING FIRE ALARM PANELS.TIE TO DEDICATED& O a N LOCKABLE 120VAC CIRCUIT.PROVIDE TWO 12V-7AH BACKUP BATTERIES. / �S SMOKE DETECTOR(CONVENTIONAL) SYSTEM SENSOR 2W-B EXIST V fO ri 3. INSTALL CEILING HORN-STROBES IN WAREHOUSE ON BOTTOM OF RAFTERS,AS f WALL STROBE SYSTEM SENSOR SRL EXIST SHOWN.VERIFY EXACT LOCATIONS.TIE TO NOTIFICATION CIRCUITS ON NEW z IN PANEL.MAXIMUM MOUNTING HEIGHT FOR CEILING DEVICES 30FT,USE FIRE ALARM SYSTEM ADDITION 3~ 1"�P WALL STROBE(WEATHERPROOF) SYSTEM SENSOR SRK EXIT PENDANTS IF NEED BE. D& CEILING HORN-STROBE SYSTEM SENSOR PC2WL 9 NEW OUTDOOR BELL SYSTEM SENSOR SSM2410 EXIST WF TS PS WATER FLOW SWITCH / TAMPER SWITCH / PRESSURE SWITCH EXISTING OFFICE OFFICE OFFICE CABLE LEGEND* OFFICE F.X.Y F#=FACP/NAC#,X=CIRCUIT#,V=DEVICE# B B OFFICE 75cd EOLR END OF LINE RESISTOR A SLC/ZONE 16 AWG,2 CONDUCTOR,FPLP N.1.6 1 EOLR 15cd [BATTERY] BACK UP BATTERIES (2x)12V-7AH B STROBE 14 AWG,2 CONDUCTOR,FPLP Z.1 E F 1.1. N.1 A QS [EOLR] N.1.5 RR B RR [CABLE] ESTIMATED TOTAL CABLE LENGTHS IT NAC.2 (1,200 FT)2#14AWG C ANN/RTS 18 AWG,4 CONDUCTOR,FPLP STORAGE DO C FACP 15cd RR 'VERIFY ALL CABLE TYPES IN PRODUCT MANUALS/SPECS CELL NACA NA.2 OFFICE N J IMPORTANT NOTES 75cd BNAO#' B 75cd Q N.1.1 N.1.3 1. DO NOT START ROUGH-IN OR INSTALL BEFORE SYSTEM IS APPROVED BY THE AHJ. SHEET INDEX L[. CONFERENCE OFFICE Q 2. INSTALLATION TO BE DONE PER NFPA 72(2019)&ALL APPLICABLE CODE REQUIREMENTS. SHEET# DESCRIPTIONL_ 7 — L > w 3. VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN. UPPER OFFICE PLAN-FIRE ALARM DEVICE PLACEMENT Q > � FA-1 COVER SHEET&FIRE ALARM DEVICE PLACEMENT ul 4. VERIFY ALL WIRING CONNECTIONS,CONDUIT, BACK-BOXES AND CABLE TYPES BEFORE Z } INSTALLATION. FA-2 RISER DIAGRAM,BATTERY CALCS &VOLTAGE DROPS 0 LO Z L Q U Q J ANN ANN #4 7 Q #3 L 185cd MANAGER B 185cd J LLI N.2.4 N.2.3 1770d EOLR N.1.1 Cl LL 7 Q I i 1 I 0 NAC.2,CKT#1 B EOLR B B B B 177cd 177cd 177cd 177cd 177cd N2.1.5 N2.1.4 N2.1.3 N2.1.2 N2.1.1 B NAC.2,CKT#2 FROM NEW MID MOUNTAIN MATERIALS [NAC2]UPSTAIRS _ 18825 67TH AVE ARLINGTON,WA 98223 NAC#2 B LAB B l\ WAREHOUSEAREA 75rd NAC#4 75®� N.2.2 B FROM N.2.1 [ LAB NAC 15cd Revisions 3.11 EOLR Rev#0(9-12-21)-ORIGINAL SHOWER NAC#3 75cd LAB B N.3.1 B 75cd Rev#1(7-5-23)-ADD NEW RR 15cd N.3.2 OFFICE WAREHOUSE NOTIFICATION N.53 10 PER FM PLAN REVIEW EOLR B B B g LUNCH STOR RR 75cd 15cd 15c g N.3. OFFICE Project# RR N.3.9 N. 177cd 177cd 177cd 177cd N2.2.4 N2.2.3 N2.2.2 N2.2.1 SHWR RR 5c5 Project Manager: 15� KEVIN DUBOIS N.3.8 OFFICE B B B Drawn By: 75cd NLH N.3.7 75 cd Date Drawn: 15cd B Z.5[EOLR] B 185 N qc1 N.3.6 7-5-23 REV#1 NAA z OFFICE OFFICE OFFICE Scale: EOLR RR 15cd [EOLR]ZA WF WF PS PS ¢#1 AS SHOWN RR N.4.3 [EOLR]Z.6 TS TS TS TS ANN #2 Sheet: [EOLR]Z.7 TS TS N 4 2 7TCOVER&LAYOUT MAIN FLOOR PLAN-FIRE ALARM DEVICE PLACEMENT m DESIGNED&REVIEWED BY: Y NICET KEVIN MILLER SCALE:1/16"=1' NICET 135024,LEVEL:III 1 CET FIRE ALARM SYSTEMS FA- 1 U IMPORTANT NOTES FIRE ALARM o 0 SEQUENCE OF 0 Z o 1. VERIFY WIRING CONNECTIONS IN INSTALLATION MANUALS BEFORE ROUGH-IN. OPERATIONS Q 2. VERIFY MOUNTING HEIGHTS WITH AHJ BEFORE ROUGH-IN. Z O 0 Z (L N W V a>a U Q > N W W O 0 Z W F- n o NOTES: Z ¢N CENTRAL STATION ALARM SERVICE ¢ O N w ^' 1 A/C SUPPLY 4" d F- � m `/ f A DIFFUSER OR INTAKE TO RECEIVE SEPARATE&DISTINCT CEILING (MIN) 0. W z SIGNALS AS FOLLOWS: lai � W 3 W BATTERY CALCULATIONS FOR NEW NAC#2 PANEL ����� ����� a 50 F- A. ALARM ¢ r r F- SUPERV. ALARM TOTAL SUP. OTAL ALARM 3' SMOKE SMOKE B. SUPERVISORY } 2 2 2 QTV MODULE DESCRIPTION CEILING DETECTOR DETECTOR Q 57 57 U) CURRENT,A CURRENT,A CURRENT,A CURRENT,A J 1 FCPS-24FS8 FIRELITE NAC PANEL 0.091000 0.145000 0.091000 0.145000 HORN I (MIN) C. TROUBLE N Z Z Z STROBE 0 F F F NOTIFICATION APPLIANCES CIRCUITS WALL 0 SRL-15 SYSTEM SENSOR 15CD WALL STROBE 0.000 0.043 0.000 0.000 HORN/ • ACTIVATION OF MANUAL PULL STATION 0 SRL-185 SYSTEM SENSOR 185CD WALL STROBE 0.000 0.222 0.000 0.000 STROBE 0 SRK-15 SYSTEM SENSOR 15CD WALL STROBE WEATHERPROOF0.000 0.066 0.000 0.000 ACTIVATION OF SMOKE DETECTOR 0 PC2WL-15 SYSTEM SENSOR 15CD CEILING HORN-STROBE 0.000 0.071 0.000 0.000 ACTIVATION OF WATER FLOW SWITCH 0 PC2WL-75 SYSTEM SENSOR 75CD CEILING HORN-STROBE 0.000 0.143 0.000 0.000 5 PC2WL-177 I SYSTEM SENSOR 177CD CEILING HORN-STROBE 0.000 0.254 0.000 1.270 ACTIVATION OF VALVE TAMPER SWITCH TOTAL CURRENT CIRCUIT#1 1.270 SYNCHRONIZE ALL DEVICES OPEN CIRCUIT • • 0 SRL-15 SYSTEM SENSOR 15CD WALL STROBE 1 0.0001 0.0431 0.0001 0.000 TROUBLE CONDITION 0 SRL-185 SYSTEM SENSOR 185CD WALL STROBE 0.0001 0.222 0.000 0.000 0 SRK-15 SYSTEM SENSOR,5CD WALL STROBE WEATHERPROO 0.000 0.066 0.000 0.000 LOSS OF PRIMARY POWER AT PANEL 0 PC2WL-15 SYSTEM SENSOR 15CD CEILING HORN-STROBE 0.000 0.071 0.000 0.000 0 PC2WL-75 SYSTEM SENSOR 75CD CEILING HORN-STROBE 0.000 0.143 0.000 0.000 91 4 PC2WL-177 SYSTEM SENSOR 177CD CEILING HORN-STROBE 0.000 0.254 0.000 1.016 TOTAL CURRENT CIRCUIT#2 1.016 0 SRL-15 SYSTEM SENSOR 15CD WALL STROBE 1 0.0001 0.0431 0.000 0.000 0 SRL-185 SYSTEM SENSOR 185CD WALL STROBE 0.Wo 0.12 0.000 0.000 0 SRK-15 SYSTEM SENSOR 15CD WALL STROBEWEATHERPROQ 0.000 0.066 0.000 0.000 90"TYPICAL FINISHED 0 PC2WL-15 SYSTEM SENSOR 15CD CEILING HORN-STROBE 0.000 0.071 0.000 0.000 ( 5' ) WALL FIRE ALARM GENERAL INFORMATION W Q 0 PC2WL-75 SYSTEM SENSOR 75CD CEILING HORN-STROBE 0.000 0.143 0.000 0.000 MAX 0 SSM2410 SYSTEM SENSOR 10^WEATHERPROOF BELL 0.000 0.0311 0.000 0.000 L TOTAL CURRENT CIRCUIT#3 0.000 A. ALL WIRING TO BE IN ACCORDANCE WITH NEC,LOCAL AUTHORITIES,AND r W MPULL L O APPLICABLE CODES.EQUIPMENT GROUNDING CONDUCTORS,IF NEEDED,ARE 0 SRL-15 SYSTEM SENSOR 15CD WALL STROBE 0.000 0.043 0.000 0.000 NOT SHOWN ON THE DRAWING,UNLESS OTHERWISE NOTED. 0 SRL-185 SYSTEM SENSOR 185CD WALL STROBE 0.000 0.222 0.000 0.000 STATION ^ ul 0 SRK-15 SYSTEM SENSOR 15CD WALL STROBE WEATHERPROO 0.000 0.066 0.000 0.000 B. DISCONNECT POWER BEFORE SERVICING SYSTEM. Z 0 PC2WL-15 SYSTEM SENSOR,5CD CEILING HORN-STROBE 0.000 0.071 0.000 0.000 fn 0 PC2WL-75 SYSTEM SENSOR 75CD CEILING HORN-STROBE 0.000 0.143 0.000 0.000 C. ALL DC ALARM SIGNALS ARE MARKED SHOWING POLARITY OF OPERATION. Ul 42"MAX ADA o SSM2410 SYSTEM SENSOR 10^WEATHERPROOF BELL 0.000 0.0311 0.000 0.000 THE POLARITY REVERSING DC ALARM INDICATING CIRCUITS ARE MARKED C TOTAL CURRENT CIRCUIT#4 0.000 SHOWING POLARITY OF SUPERVISION. CONNECT ONLY 24VDC POLARIZED L G ALARM SIGNAL. r TOTAL ALARM CURRENT 2.431 Q �( TOTAL SUPERVISORY CURRENT 0.091 D. ALL SUPPLEMENTARY POWER MUST BE FUSED.USE ONLY UL LISTED POWER �1 TOTAL STANDBY HOURS 24 FINISHED FLOOR SUPPLY FOR FIRE PROTECTIVE SERVICE. [- Z J TOTAL SUPERVISORY CAPACITY 2.184 Q E. INSTALLATION TO BE PER NFPA 72(2019). Z _ ALARM PERIOD IN MINUTES 10 F. SEE INSTALLATION INSTRUCTIONS SHEET PACKAGED WITH FIRE ALARM '�I W TOTAL ALARM TOTAL ALARM AND SUPTY 0.405ERVISORY ERVISORY CAPACITY 2.589 FIRE ALARM TYPICAL DEVICE MOUNTING HEIGHTS SYSTEM DEVICES FOR ADDITIONAL INFORMATION. TOTAL AMP-HOURS REQUIRED(AFTER 20%DERATING FACTOR) 3.107 G. SEE DATA MANUAL(S)FOR ADDITIONAL INFORMATION. LL ILL PROVIDE TWO(2)12V-7AH BATTERIES (VERIFY EXACT PLACEMENT BEFORE INSTALL) Q H. MAKE SURE THAT ALL POWER-LIMITED/CLASS 2 WIRING IS SEPARATED AT 1 LEAST 0.25 INCH FROM ANY WIRING THAT IS NOT POWER-LIMITED. VOLTAGE DROP CALCULATIONS FOR NEW NAC#2 PANEL I. LOOP WIRE IN ALL J BOXES FROM TOP OF CAN TO BOTTOM OF CAN BACK TO I..I TOP. CIRCUIT#1 427 J. TO PREVENT CONFUSION AND POSSIBLE ERRORS,ALL CONDUCTORS SHOULD VOLTAGE APPLIED(VOLTS) 2 BE TAGGED OR OTHERWISE CODED AND LOGGED, AT INSTALLATION,TO WIRE RUN LENGTH(FEET) 27 BE CIRCUIT ASSIGNMENT, POLARITY,AND WHETHER THE WIRING IS WIRE RUN CURRENT(AMPS) 1.270 OUTGOING OR RETURN. WIRE SIZE(AWG) 14 VOLTAGE DROP(%) 16.32% K. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. END OF RUN VOLTAGE(VOLTS) 17.07 CIRCUIT#2 L. CIRCUITS TO BE DESIGNED AS A CLASS B(STYLE Y)SYSTEM. VOLTAGE APPLIED(VOLTS) 20.40 WIRE RUN LENGTH(FEET) 474 MID MOUNTAIN MATERIALS WIRE RUN CURRENT(AMPS) 1.016 18825 67TH AVE WIRE SIZE(AWG) 14 VOLTAGE DROP(%) 14.49% ARLINGTON,WA 98223 END OF RUN VOLTAGE(VOLTS) 17.44 CELLULAR C 1 DIALER Revisions STARLINK Rev#0(9-12-21)-ORIGINAL ABOVE FACP TO 120VAC CKT- Rev#1(7-5-23)-ADD NEW FACP DIED.&LOCK B WAREHOUSE NOTIFICATION VISTA128FBPT NAC CKT#1-WAREHOUSE NOTIFICATION PER FM PLAN REVIEW FIRE HONEYWELL NEW Project# DOCUMENTS NACA NAC.2 B CABINET EXISTING FIRELITE NAC CKT#2-WAREHOUSE NOTIFICATION Project Manager: NEXT TO FACP FCPS-24FS8 KEVIN DUBOIS NAC CKT#3-SPARE Drawn By: (EXIST) (B,NEW NLH Date Drawn: REMOTE C REMOTE C REMOTE C REMOTE C FACPBELLCKT INPUT#1 FA PBELLCKTCONT. INPUT#1 NACCKT#4-SPARE 7-5-23REV#1 ANNUNCIATOR ANNUNCIATOR ANNUNCIATOR ANNUNCIATOR Scale: #4 #3 #2 #1 2x 12V-10AH 2x 12V-7AH BATTERIES(PARALLEL) BATTERIES Sheet: EAST SHOP-S ENTRY EAST SHOP-N.ENTRY WEST SHOP-S.W.ENTRY OFFICE N.W.ENTRY UPSTAIRS I.T.ROOM NEXT TO FACP NEXT TO FACP RISER/BATT CALCS MANAGER OFFICE (VERIFY LOCATION) FIRE ALARM RISER DIAGRAM FA- ADT Commercial 11824 N. Creek Pkwy, Suite 105 Bothell, WA 98011 -8204 425.949.8046 Reference: Fire Alarm System - Upgrade Mid Mountain Materials 18825 67t" Ave. Arlington, WA 98223 DEVICE DATA SHEETS REVISION #1 - 7/5/23 PER FIRE MARSHAL REQUEST: ADDING NOTIFICATION INSIDE WAREHOUSE Honeywell Home Control Panels VISTA-128 FB P/V128 FB P-24 VISTA" Commercial Partitioned Fire and Burglary Alarm Control Panel The VISTA-128FBP provides the ultimate protection of life and property.This UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points .M! ' using hardwired,wireless and V-Plex'addressable technologies. A diverse line of Honeywell Home initiating devices, notification circuits,communication devices, keypads, RF receivers and relays are also supported.The VISTA-128FBP has been designed to mount Now UL864 9th Edition Approved quickly and easily in an attack resistant cabinet,and is available in 12V and 24V models. FEATURES • Eight hardwired zones standard, • Supports V-Plex addressable • Supports Internet and GSM expandable to 120 V-Plex VISTAKEY access control alarm reporting* addressable points/zones or (1 to 8 doors) • Supports graphical user interfaces 128 wireless points/zones • Two on-board notification(bell) for burglary use • Can control eight separate areas circuits delivering 2.3A @ 12V . Supports 6160CR-2 multi-LED independently(8 partitions) . Automatic smoke detector sensitivity fire keypad • Supports commercial wireless fire maintenance testing • Listed to UL8649th Edition and burglary devices • Four-wire smoke reset using • Upload/download via Ethernet* • Stores up to 512 events onboard J2 output trigger • Carbon monoxide(CO) • Accommodates 150 user codes • Supports dynamic signaling for zone support and up to 250 access card holders Alarm Net'Communicators using VISTAKEY' *When used with Alarm Net'devices. VISTA-128FBPNUMP-24 VISTA"° Commercial Partitioned Fire and Burglary Alarm Control Panel ADDITIONAL FEATURES • Notification Appliance Circuits(two): -Individually assignable to any - Eight zone-Class B -Programmable of eight partitions expander module -Temporal code compliant - Up to 16 two-wire smoke detectors - Single-zone supervised -Individually silenceable each on zone one and two contact module • Programmable on-board (32 total) • UL Listed wireless expansion auxiliary relay - Up to 50 two-wire glassbreak - Supports up to 128 wireless detectors on zone eight zones/points • False alarm reduction features: -Exit error logic Patented addressable V-Plex - Supervised by control for -Exit delay reset polling loop technology check-in signals -Cross zoning - Supports 120 two-wire zones - Tamper protection fortransmitters -Callwaiting defeat points Individually assignable up to -Recent close report - Global polling technology for eight partitions faster processing - Supports commercial wireless • Supports commercial hardwired, - Supervised by panel smoke detectors addressable V-Plex°polling loop - Zones individually assignable to • Up to eight doors using VISTAKEY and wireless zones partitions,notification circuit(bell) V-Plex Access Control • Hardwired zones output or auxiliary relay • Event reporting • Provides eight style B - 4,000ft.capability without the use • Local printer for event log printing hardwired zones of shielded cable -EOLR supervised for Fire and UL - Extender/Isolation bus modules • Communication burglary installations-Supports - Eight zone-Class A and B - Phone line,GSM and IP N.O.or N.0 sensors expander module communicator support - Panel operation during download VISTA-128FBPNUMP-24 VISTA"° Commercial Partitioned Fire and Burglary Alarm Control Panel SPECIFICATIONS Applications: Main Dialer: Agency Listings: The VISTA-128FBP control is well Line seize:Double Pole U L609 Grade A Local Mercantile suited for a variety of applications Ringer equiv:0.7B Premises and Mercantile Safe as an integrated fire and burglary Formats:ADEMCO®Low Speed, and Vault control.Some of the applications ADEMCO 4+2 Express,ADEMCO U L611/1610 Grades A,AA, supported are:medical and High Speed,ADEMCO Contact ID, Central Station professional buildings,churches or Sescoa and Radionics U L365 Grades A,AA Police Connect synagogues,office buildings,schools, Backup Communication: UL864/NFPA72 Local,Central strip malls,larger residences and p Station and Remote Station factory or warehouse environments. Dual phone line capability using Electrical: 5140DLM module Alarm Net®GSM, UL985 Primary power:18VAC C 72VA i-GSM and IP Communicators Factory Mutual Honeywell No.1451 Cabinet Dimensions: California State Fire Marshal Control panel quiescent current 18"H x 14.5"W x 4.3"D M EA draw:300mA CAN/ULC S304—Central and Environmental: Monitoring Station Burglar Alarm Unit Backup battery: Storage temp:141Fto 1581E 12VDC,12AH min to 34.4AH max (-101C to 701C) CAN/ULC S527—Central Unit for Fire Lead acid battery(gel type) 1 1 Alarm Systems Alarm power:l2VDC,1.7A max Operating/temp:32 F to 122 F CAN/ULC S303—Local Burglar for each notification(bell)circuit (0 C 50 C) Alarm Unit output Total2.3A 12V Humiddity:85%RH CAN/ULC S525—Audible Aux.standby pwr:12VDC,lA max EMI:Meets or exceeds the following Signal Appliances requirements: Total power:2.3A at 12VDC -FCC Part 15,Class B Device Standby time:24 hours with 1A -FCC Part 68 standby load using 34.4AH battery -IEC EMC Directive Fusing:Battery input,aux.and notification(bell)circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Optional24-volt kit VISTA-128FBP/VUMP-24 VISTA' Commercial Partitioned Fire and Burglary Alarm Control Panel COMPATIBLE DEVICES Auxiliary Devices 4193SN and 4193SNP Two-zone 5881ENHC- RF Receiver 6160CR-2- Red Fire Keypad Expander Modules 5883H-RF Receiver 6160- Burglary Keypad V-Plex Extender/Isolation Modules Access Control 4204- Relay Module,four form C 4297 Extender/Isolator Module VISTAKEY®V-Plex(addressable) contacts VSI Isolator Module Access Control 4204CF-Two supervised output V-Plex Smoke Detectors VISTAKEY-SK Starter Kit circuits 5881 Series RF receiver 5193SD VISTAKEY-EX Expansion Kit 5883H RF receiver 5193SDT Alarm Communications 6220S-System printer used with V-Plex Passive Infrared Detectors 7845i-ENT- Internet/Intranet 4100SM serial module 998MX Communicator Two-Wire Smoke Detectors IS2500SN 7845GSM- Digital Cellular Conventional DT7500SN Communicator 7845i-GSM- Internet and Digital System Sensor V-Plex(Addressable)Contacts Cellular Communicator ESL 4939SN-WH GSMCF/iGSMCF-Commercial Fire DSC 4944SN-WH Communication Kits(when available) Horn/Strobes 4959SN IPGSM-DP Internet and Digital Cellular System Sensor V-Plex Glassbreak Detectors Communicator Wheelock FG1625SN M EA Gentex CAN/ULC S304—Central and Optional 24V Kit Monitoring Station Burglar Alarm Unit Manual Pull Stations Order number:V128FBP924KT 5140M PS-1 CAN/ULC S527—Central Unit for Fire 5140M PS-2 Commercial Wireless Devices Alarm Systems 5808W3- Photoelectric Smoke/Heat CAN/ULC S303— Local Burglar V-Plex(Addressable)Devices Detector Alarm Unit 4208U Universal Eight-zone Expansion 5806W3- Photoelectric Smoke CAN/ULC S525—Audible Signal Module Detector Appliances 4101SN Single Relay/Zone Module 5809-Wireless Heat Detector 4208SNF Class A/B Expander Module 5817CB-Wireless Commercial Product specifications subjectto change. 4190SN Remote Point Module- Transmitter two zones 5869- Hold-Up Transmitter ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information security.honeywellhome.com r resideo Alltrademarks are property Resideo Technologies,Inc. of their respective owners. 2 Corporate Center Drive,Suite 100 L/VSTA128FBPD/D 1 08/19 P.O.Box 9040 ©2019 Resideo Technologies,Inc. This product is manufactured Melville,NY 11747 by Resideo and its affiliates.The 1-800-645-7492 Honeywell Home trademark is used un sedun Honeywell resideo.com International Inc.All rights reserved. Honeywell ll Home DF-52310:A3•D-50 FOPS-24FS8(C/E) Flre•LITe�ALarmS 8 Am 24 Volt p� Remote Power Supply by Honeywell Power Supplies The Fire-Lite FCPS-24FS8(C/E) is a compact, cost-effective, 8- amp remote power supplies with battery charger. The FCPS- 24FS8C/E)may be connected to any 12 or 24 volt fire alarm control • • . panel(FACP)or may stand-alone. Primary applications include noti- fication appliance (bell) circuit (NAC) expansion (to support ADA ' ' • requirements and NAC synchronization) or auxiliary power to sup- • • port 24 volt system accessories. The FCPS provides regulated and `• • • filtered 24 VDC power to four notification appliance circuits config- ured as either two Class B (Style Y) and Class A (Style Z, with ' • • ZNAC 4 option module)or four class B only.Alternately,the four out- ' • • puts may be configured as any combination of resettable/non-reset- ' • table power outputs (optimal for powering four-wire smoke ' • • • detectors. The FCPS-24FS8(C/E) also contains a battery charger • • i capable of charging up to 18.0 Amp hour batteries. The FCPS- 24FS8C is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS8 used in this document refers to the FCPS-24FS8, FCPS-24FS8C, and FCPS- • 24FS8E. • • Features • UL-Listed Notification Appliance Circuit (NAC) synchronization using System Sensor®, Wheelock®, or Gentex®"Commander2" appliances • Operates as a "sync-follower" or as a "sync-generator" (default) See note on page 2. '` • Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode)or jumped permanently"ON" (stand-alone mode) • Two Class B (Style Y)or Class A(Style Z,with ZNAC-4 module) NACs(circuits 1 &3) • 8-amp full load output, with 3 amps maximum/circuit, in NAC expander mode(UL 864) Specifications • 6-amp continuous output in stand-alone mode(UL 1481) Primary(AC)Power: • Compatible with coded inputs;signals passed through FCPS-24FS8/C: 120 VAC,60 Hz,3.2A maximum • Optional power-supervision relay(EOLR-1) FCPS-24FS8E:240 VAC,50 Hz, 1.6A maximum • In stand-alone mode,output power circuits may be configured as: Wire Size: minimum#14 AWG (2.Omm2)with 600 V insulation resettable, (reset line from FACP required), non-resettable, or a mix of two and two Control Input Circuit: • Fully regulated and filtered power output - optimal for powering Trigger Input Voltage: 9 to 32 VDC four-wire smoke detectors, annunciators, and other system Trigger Current:2.0 mA(16-32 V); Per Input: 1.0 mA(9- 16 V) peripherals requiring regulated/filtered power Trouble Contact Rating: 5 A at 24 VDC • Power-limiting technology meets UL power-limiting requirements. Auxiliary Power Output: Special application power 500 mA maxi- • Form-C normally-closed trouble relay mum • Fully supervised power supply,battery,and NACs Output Circuits: • Selectable earth fault detection • +24 VDC filtered,regulated • AC trouble report selectable for immediate 2-hour delay 3.0 A maximum for any one circuit • Works with virtually any UL 864 fire alarm control which utilizes Total continuous current for all outputs(stand-alone mode): an industry-standard reverse-polarity notification circuit(including 6.0 A maximum unfiltered and unregulated bell power) • Requires input trigger voltage of 9-32 VDC Total short-term current for all outputs(NAC expander mode): 8.0 A maximum • Self-contained in compact, locking cabinet - 15"H x 14.5"W x Secondary Power(Battery)Charging Circuit: 2.75"D(cm:38.1 H x 36.83W x 6.985D) • Includes integral battery charger capable of charging up to 18 AH Supports lead-acid batteries only batteries. Cabinet capable of housing 7.0 AH batteries Float-charge voltage:27.6 VDC • Battery charger may be disabled via DIP switch for applications Maximum current charge:250 mA requiring larger batteries Maximum battery capacity:7.0 AH • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2)wire DF-52310:A3•11/4/2019—Page 1 of 2 Applications Standards and Codes Example 1: Expand notification appliance power an additional 8 The FCPS-24FS8 complies with the following standards: amps. Use up to four Class B(Style Y)outputs or four Class A(Style NFPA 72 National Fire Alarm Code Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity acti- vation occurs. Trouble conditions on the FCPS are sensed by the expander mode) FACP through the notification appliance circuit. UL 1481 Power Supplies for Fire Alarm Systems Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 6 amps. Both resettable and non-resettable Agency Listings and Approvals power options are available. Resettable outputs are created by con- These listings and approvals apply to the modules specified in this necting the resettable output from the FACP to one or both of the document. In some cases, certain modules or applications may not FCPS inputs. be listed by certain approval agencies, or listing may be in process. Example 3: Use addressable control modules to activate the FCPS Consult factory for latest listing status. instead of activating it through the FACP notification appliance cir- . UL Listed: S2424 cuits. This typically allows for mounting the FCPS at greater dis- . ULC Listed: S2424 tances*away from the FACP while expanding system architecture in various applications. • CSFM Approved: 7315-0075:0206 For example, an addressable control module is used to activate the ' MEA:219-02E FCPS, and an addressable monitor module is used to sense FCPS • FM Approved trouble conditions. Local auxiliary power output from the FCPS pro- vides power to the addressable control module. Ordering Information *NOTE:Addressable FACPs are capable of locating control and monitor FCPS-24FS8: 8.0 A, 120 VAC remote charger power supply. modules at distances of up to 10,000 feet(3,046 meters). Includes main printed circuit board, transformers,enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation Sync Follower/Generator Note instructions In some installations, it is necessary to synchronize the flash timing FCPS-24FS8C: Same as FCPS-24FS8, ULC-Listed of all strobes in the system for ADA compliance.Strobes accomplish FCPS-24FS8E: 8.0 A, 240 VAC remote charger power supply. this by monitoring very short timing pulses on the NAC power which Includes main printed circuit board, transformers,enclosure (15"H x are created by the FACP. When installed at the end of a NAC wire 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation run, the FCPS-24FS8 can track (i.e. "follow") the strobe synchroni- instructions zation timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to ZNAC-4: Class A(Style Y)NAC option module the FCPS. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-24FS8 is configured (via DIP switch settings)as a smoke detector power "sync follower," the FCPS' NAC outputs track the strobe synchroni- BAT-1270: Battery, 12-volt, 7.0 AH (two required) zation pulses present at the FCPS' sync input terminal. The pulses originate from an upstream FACP or other power supply. PS-1270: Battery, 12-volt,7.0 AH (two required) When the FCPS-24FS8 is configured (via DIP switch settings)as a 90286: Optional module mounting kit, is required to install an "sync generator," the FCPS' sync input terminals are not used. addressable module on the power supply main circuit board Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS' NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Fire•LiteO Alarms and System Sensor®are registered trademarks of Honeywell International, Inc. Wheelock®is a registered trademark of Cooper Technologies Company.Gentex®is a registered trademark of Gentex Corporation. ©2019 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING U MANUFACTURING QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www.firelite.com Page 2 of 2—DF-52310:A3•11/4/2019 SYSTEM SEIVSOR° Indoor Selectable- s Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut -_ installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30, 75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box, making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING @ AFM11.1.? X LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 AVDS868-02•12/01/2017•Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS666-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47'(62.7 mm) 1.37"(34.8 mm) 6.92'diam. 2.5' (173 mm) 6 diam. (175.77 mm) (64 mm)� 17 OppT►AO O�PK O lA O o CD 0 0 O O O O o CD o 0 A0545-00 AOb46-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box QD :30 91 �1 Np[PA\NT SPA\Pi �o�000®moo \ � pppp °gip �p°p0o�®mmm�DOO\, o°oo 0 opal° 00 0 A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information DescriptionModel Description Model Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe, Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". f� SYSTEM 02017 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product opccificationo oubjcct to changc without notice.Visit oystcmocnooccom SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 for current product information,868C-Oding the 1/2017 version oftlis data sheet. AVDS888-02.12/01/2017 FIRE ALARM LEGEND& MATERIAL LIST SYMBOL DESCRIPTION MANUFACTURER PARTNUMBER QTY. U 1.L FIRE ALARM CONTROL PANEL HONEYWELL VISTA V128FBPT EXIST MID MOUNTAIN MATERIALS F-AN-N-1 FIRE ALARM REMOTE ANNUNCIATOR HONEYWELL 6160CR-2 EXIST SCOPE OF WORK: ADD NOTIFICATION TO WAREHOUSE cELL FIRE CELLULAR COMMUNICATOR NAPCO SLE-LTEV-FIRE E IsT 1 1. THIS IS AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM INSTALLED 7/2021. 18825 6/ 11 7}h 1 AVE E o a NAC I NAC BOO TER POWER SUPPLY FIRELITE FOPS-24FS8 1 NEW FOR THIS 2023 UPDATE THE FIRE MARSHAL WANTS NOTIFICATION ADDED INSIDE THE WAREHOUSE AREA AS SHOWN. >u F—DOC-1 FIRE DOC JMENTS CABINET MIERPRODUCTS Bw-Doceox EXIST 2, INSTALL NEW NOTIFICATION BOOSTER POWER SUPPLY(NAC#2 PANEL)UPSTAIRS ° o j] MANUAL ULL STATION(CONVENTIONAL) FIRELITE BG-12 EXIST IN IT CLOSET NEXT TO EXISTING FIRE ALARM PANELS,TIE TO DEDICATED& A R L I N G TO N WA 98223 � O o LOCKABLE 120VAC CIRCUIT.PROVIDE TWO 12V-7AH BACKUP BATTERIES. w M QS SMOKEDETECTOR(CONVENTIONAL) SYSTEM SENSOR 2W-B EXIST U 3. INSTALL CEILING HORN-STROBES IN WAREHOUSE ON BOTTOM OF RAFTERS,AS f o SHOWN.VERIFY EXACT LOCATIONS.TIE TO NOTIFICATION CIRCUITS NEW FIRE ALARM SYSTEM ADDITION J { WALL STROBE SYSTEM SENSOR SRL EXIST ON NAC#2 PANEL.MAXIMUM MOUNTING HEIGHT FOR CEILING DEVICES OF USE 3 v PENDANTS IF NEED BE. JxWR WALLST BE(WEATHERPROOF) SYSTEM SENSOR SRK XI T N 1 P D& CEILING RN-STROBE SYSTEM SENSOR PC2WL 9 NEW OUTDOOF BELL SYSTEM SENSOR SSM2410 EXIST Dm WF FTSI FP7S WATER F W SWITCH / TAMPER SWITCH / PRESSURE SWITCH EXISTING OFFICE OFFICE OFFICE CABLE LEGEND* OFFICE F.X.Y F#=FACP NAC#,X=CIRCUIT#,Y=DEVICE# B B OFFICE 75cd EOLR END OF LI qE RESISTOR 1 A SLC/ZONE 16 AWG,2 CONDUCTOR,FPLP NA S 15cd (BATTERY] BACKUP BATTERIES (2x)12V-7AH B STROBE 14 AWG,2 CONDUCTOR,FPLP 2.1 .2 F 1 A. N.1.4 QS [FOLK] N.15 RR B RR [CABLE] ESTIMATE TOTAL CABLE LENGTHS (1,200 FT)2#14AWG C ANN/RTS 18 AWG,4 CONDUCTOR,FPLP STORAGE I.T. NAC.2 DOC FACP 15cd RR 'VERIFY ALL CABLE TYPES IN PRODUCT MANUALS/SPECS CELL NAC.i N.12 ul OFFICE J IMPORTANT NOTES 7 d BNAC#1 N c3 Q It 1. DO NOT START R UGH-IN OR INSTALL BEFORE SYSTEM IS APPROVED BY THE AHJ. SHEET INDEX CONFERENCE OFFICE W 2. INSTALLATION TO E DONE PER NFPA 72(2019)&ALL APPLICABLE CODE REQUIREMENTS. SHEET# DESCRIPTION 7 1W �- 3 W 3. VERIFY EXACT LO1,ATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN. FA-1 COVER SHEET&FIRE ALARM DEVICE PLACEMENT UPPER OFFICE PLAN-FIRE ALARM DEVICE PLACEMENT Q w 4. VERIFY ALL WIRIP G CONNECTIONS,CONDUIT, BACK-BOXES AND CABLE TYPES BEFORE 7 >- INSTALLATION. FA-2 RISER DIAGRAM,BATTERY CALCS &VOLTAGE DROPS LO U] Z � � Q 7� Q ANN ANV #4 Z `� Q #3 185cd MANAGER 185W J W N.2.4 N.2.3 177cd f V EOLR N.1.1 O LL 1 O NAC.2,CKT#1 B EOLR B B B B C G 177cd 177cd 177cd 1770d 177cd N2.1.5 N2.1.4 N2.1.3 IJ2.1.2 N2.1.1 NAC.2,CKT#2 FROM NEW MID MOUNTAIN MATERIALS [NAC.21 UPSTAIRS 18825 07TH AVE NAC#2 ARLINGTON,WA 98223 B LAB B WAREHOUSEAREA 75cd NAC#4 75cd N.2.2 BI FROM N.2.1 LAB NAC I 75cd Revisions 3.11 OFFICE COPY FOUR ReW0(9-12.21)-ORIGINAL SHOWER NAC#3 75cdALA137 B N.3.1 CITY OF ARLgGTON Rev#1(7-5-23)-ADD NEW 75cdOFFICE RRN.3.10 BUILDING DEPARTMENT WAREHOUSE NOTIFICATION APPROV7D 75c 1 PER FM PLAN REVIEW EOLR B B B B LUNCH CAT" BY `y'-��/ 75cdN.3. OFFICE —+—ter— Project# RR N.3.9177cd 177od 177cd 77cd N2.2.4 N2.2.3 N2.2.2 2.2.1 Sh WR U UILDINi15cdBUILUING IfvSf'EG ..,< Project Manager: N.3.8KEVIN DUBOIS B Drawn By: NLH N.3.7750d Received Date Drawn: 1 5`.d N.3.6 7-5-23 REV#1 i 5cd Z.5:EOLR] 4.1 NAA Z OFFICE OFFICE OFFICE EOLR i5cd [EOLRi Z.4 WF WF �q PS z AUG 02 2023 $Gels: 4R RR N.4.3 [FOLK]Z.6 7S TS TS P.NN ¢#1 ',}��f �,.fy1 AS SHOWN [FOLK]Z 7 TS TS V Sheet: N.4.2 COVER&LAYOUT a MAIN FLOOR PLAN-FIRE ALARM DEVICE PLACEMENT m DESIGNED&REVIEWED BY: SCALE:1/16"=1' KEVIN MILLER NICER ALARM LEVEL:III FA- 1 CET FIRE ALARM SYSTEMS U IMPORTANT NOTES FIRE ALARM o SEQUENCE OF o a 1. VERIFY WIRING CONNECTIONS IN INSTALLATION MANUALS BEFORE ROUGH-IN. OPERATIONS Q to to O,p 2. VERIFY MOUNTING HEIGHTS WITH AHJ BEFORE ROUGH-IN. W Z O 0 Z W N K M (L > >O K U x O a 00 z w0. O o NOTES: z U) a N zN CENTRAL STATION ALARM SERVICE ¢ O w 1 A/C SUPPLY m DIFFUSER OR INTAKE ����4 TO RECEIVE SEPARATE&DISTINCT U it w � z BATTERY CALCULATIONS FOR NEW NAC#2 PANEL ����� ���� CEILINGMIN� SIGNALS AS FOLLOWS: a a O - -� A. ALARM < CO F- 6 --�.• - M KE SMOKE } g g SUPERV. ALARM roTALSUP. OTALALAR B. SUPERVISORY a TY MODULE DESCRIPTION CEILING CURRENT,A CURREM,A CURRENT,A CURRENT,A DETE TOR DETECTOR J to m i FCPS-24F53 FIRELITE NAC PAN L 0.091000 0.145000 0.091000 0.1450W HORN/ '.'�') -� C. TROUBLE D- Z Z Z STROBE O NOTIFICATION APPLIANCES CIRCUITS WALL 0 SRL-15 SYSTEM SENSOR 1 D WALL STROBE 0.000 0.043 O.ODO 0.000 HORN/ ACTIVATION OF MANUAL PULL STATION • • 0 SRL-785 SYSTEM SENSOR 1 CD WALL STROBE Q000 0.222 0.000 0.000 STROBE 0 SRK-15 SYSTEM SENSOR 1 D WALL STROBE WEATHERPROO 0.000 0.066 0.000 0.000 ACTIVATION OF SMOKE DETECTOR • • 0 PC2NL-15 SYSTEM SENSOR I DCEILINGHORN-STROBE 0.000 0.G71 0.000 0.000 ACTIVATION OF WATER FLOW SWITCH • • 0 PC2WL-75 SYSTEM SENSOR DCEILING HORN-STROBE O.00D N. 0.OW 0.000 s PczWL-m SYSTEM SENSOR i CD CEILING HORN-STROBE 0.000 N. 0.000 1.rro ACTIVATION OF VALVE TAMPER SWITCH • • TOTAL CURRENT CIRCUIT#1 1.270 SYNCHRONIZE ALL DEVICES OPEN CIRCUIT • • 0 =SYSTEMYSTEM SENSOR 1 D WALLSTROBE 0.000 0.043 0.000 0.0000YSTEM SENSOR 1 D WALL STROBE G000 0.222 0000 0,000TROUBLE CONDITION0YSTEM SENSOR 1 D WALL STROBE WEATHERPROO 0.000 0.0" 00000000LOSS OF PRIMARY POWER AT PANELYSTEM SENSOR 15CD CEILING HORN-STROBE O.OW 0.071 0.000 O.ODDSTEM SENSOR DCEILING HORN-STROBE DOW 0.143 0.000 O.ODD STEM SENSOR 1 CD CEILING HORNSTROBE 0.000 0.254 0.000 1.016 TOTAL CURRENT CIRCUIT#2 1.016 J 0 SIR SYSTEM SENSOR 15CD WALL STROBE 0,000 0.043 0.000 0.000 Q 0 SRL-185 SYSTEM SENSOR 1 D WALL STROBE 0.000 0.222 0.000 0.000 0 SRK55 SYSTEMSENSORI D WALL STROBE WEATHERPROO 0.000 OA6fi 0.000 0.000 g0"TYPICAL FINISHED 0 PC2WL-15 SYSTEMSENSORI DCEIUNGHORN-STROBE 0.000 2A11 O.D00 0.0m FIRE ALARM GENERAL INFORMATION 5' WALL 0 PC2NL-75 SYSTEM D CEILING HORN-STROBE 0.000 0.143 0.000 0.000 (MAX) W Q 0 SSM2410 SYSTEM SENSOR 1 WEATHERPROOF BELL 0.000 0.031 0.000 0.000 LL TOTAL CURRENT CIRCUIT#3 0.000 MANUAL O A ALL WIRING TO BE IN ACCORDANCE WITH NEC,LOCAL AUTHORITIES,AND r 3 W PULL APPLICABLE CODES.EQUIPMENT GROUNDING CONDUCTORS,IF NEEDED,ARE 0 SRL-15 SYSTEM SENSOR 1 D WALL STROBE 0.000 0.043 0.000 0.000 NOT SHOWN ON THE DRAWING,UNLESS OTHERWISE NOTED. 0 SRL-185 SYSTEM SENSOR 1 D WALL STROBE 0.000 0.222 0.000 0.000 STATION .. (n 0 SRK-15 SYSTEM SENSOR 1 D WALL STROBE WEATHERPROOF0.000 0.066 0.000 0.000 B. DISCONNECT POWER BEFORE SERVICING SYSTEM. Z } 0 PCZWL-15 SYSTEM SENSOR 1 DCEILING HORN-STROBE 0.000 0.071 0.000 0.000 0 PC2WL-75 SYSTEM SENSOR DCEILING HORN-STROBE 0.000 0.143 0.000 0.000 42"MAX ADA C. ALL DC ALARM SIGNALS ARE MARKED SHOWING POLARITY OF OPERATION. LO 0 SSM2410 SYSTEM SENSOR 1 WEATHERPROOF BELL 0.000 0.031 0.000 0.000 ( ) THE POLARITY REVERSING DC ALARM INDICATING CIRCUITS ARE MARKED c TOTAL CURRENT CIRCUIT#4 0.000 SHOWING POLARITY OF SUPERVISION.CONNECT ONLY 24VDC POLARIZED L G ALARM SIGNAL. - I r���1 TOTAL ALARM CURRENT 0,091 0 TOTAL SUPERVISORY CURRENT 0'�1 FINISHED FLOOR D. SUPPLY FOR FIRE ROTECNTARY WTIVE SERVICE.R MUST BE FUSED.USE ONLY UL LISTED POWER uu TOTAL STANDBY HOURS 24 --j TOTAL SUPERVISORY CAPACITY 2.184 if E. INSTALLATION TO BE PER NFPA 72(2019). 7 �I �l ALARM PERIOD IN MINUTES 10 F. SEE INSTALLATION INSTRUCTIONS SHEET PACKAGED WITH FIRE ALARM J L^ W TOTALT ALARM ALARM ANDSU TY ERVISORY CAPACI � FIRE ALARM TYPICAL DEVICE MOUNTING HEI HTS SYSTEM DEVICES FOR ADDITIONAL INFORMATION. J ry PROVIDE TWO(2)12V-7AH BATTERIES Q MP-HOURS REQUIRED (VERIFY EXACT PLACEMENT BEFORE INSTALL)(AFTER DEBATING FACTOR) 3.107 G. SEE DATA MANUAL(S)FOR ADDITIONAL INFORMATION. D LL W PROVI H. MAKE SURE THAT ALL POWER-LIMITED/CLASS 2 WIRING IS SEPARATED AT 1 LEAST 0.25 INCH FROM ANY WIRING THAT IS NOT POWER-LIMITED. I. LOOP WIRE IN ALL J BOXES FROM TOP OF CAN TO BOTTOM OF CAN BACK TO Q VOLTAGE DRO CALCULATIONS FOR NEW NAC#2 PANEL TOP. CIRCUIT#1 J. TO PREVENT CONFUSION AND POSSIBLE ERRORS,ALL CONDUCTORS SHOULD VOLTAGE APPLIED(VOLTS) 20.40 BE TAGGED OR OTHERWISE CODED AND LOGGED,AT INSTALLATION,TO WIRE RUN LENGTH(FEET) 427 IDENTIFY CIRCUIT ASSIGNMENT, POLARITY,AND WHETHER THE WIRING IS WIRE RUN CURRENT(AMPS) 1.270 OUTGOING OR RETURN. WIRE SIZE(AWO) 14 VOLTAGE DROP% 1632% K LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. END OF RUN VOLTAGE(VOLTS) ,n7 GRCUIT#2 L CIRCUITS TO BE DESIGNED AS A CLASS B(STYLE Y)SYSTEM. VOLTAGE APPLIED(VOLTS) �.40 WIRE RUN LENGTH(FEET) 474 FrMID MOUNTAIN MATERIALS WIRE RUN CURRENT(AMPS) .14 18825 67TH AVE WIRE SIZE(AWG) VOLTAGE DROP(%) 14.49% RLINGTON,WA 98223 END OF RUN VOLTAGE(VOLTS) 17.44 CELLULAR C 1 DIALER Revisions STARLINK Rev#0(9.12-21)-ORIGINAL ABOVE FRCP TO 120VAC CKT Rev#1(7-5-23)-ADD NEW FACP DED.&LOCK B WAREHOUSE NOTIFICATION VISTA128FBPT NAC CKT#1-WAREHOUSE NOTIFICATION HONEYWELL PER FM PLAN REVIEW FIRE NEW Project# DOCUMENTS NAC.1 NAC.2 B CABINET EXISTING FIRELITE NAC CKT#2-WAREHOUSE NOTIFICATION Project Manager: NEXT TO FACP FCPS-24FS8 KEVIN DUBOIS NAC CKT#3-SPARE Drawn By: (EXIST) (B,NE NLH Date Drawn: REMOTE C REMOTE C REMOTE C EEE C FACP BELL CKT NPUT#1 FA P BELL CKT CONT. INPUT#1 NAC CKTtf4-SPARE 7-5-23 REV#1 ANNUNCIATOR ANNUNCIATOR ANNUNCIATOR A Scale: #4 #3 #2 2x 12V-10AH 2x 12V-7AH BATTERIES(PARALLEL) BATTERIES EAST SHOP-SENTRY EAST SHOP-N.ENTRY WEST SHOP-S.W.ENTRY OFFICE N.W.ENTRY Sheet: MANAGER OFFICE UPSTAIRS I.T.ROOM NEXT TO FACP NEXT TO FACP (VERIFY LOCATION) RISER!BATT CALCS FIRE ALARM RISER DIAGRAM FA-2 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18825 67TH AVE NE Permit#:5514 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31051400302700 DATE OF ISSUANCE. Scope of Work:Additional work per BLD4163.Adding 10 notification devices in Valuation:29610.63 warehouse area OWNER APPLICANT CONTRACTOR M3 FINANCIAL MANAGEMENT LLC ADT Commercial LLC ADT Commercial 7600 5TH AVE S 600 Oakesdale Ave SW 600 Oaksdale Ave SE, Suite A SEATTLE,WA 98108 Renton,WA 98057 Renton,WA 98057 206-586-6343 425-970-4359 LIC:602 805 295 EXP:04/30/2024 LIC:ADTCOCL80IK6 EXP:05/28/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC IO/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. UipZ� dQ �GLrG ti3O�� 08/10/2023 Applicant Signature Date Building Official Date CONDITIONS APPROVED JOB COPY SHALL BE ONSITE FOR INSTALLATION AND INSPECTIONS.ADHERE TO APPROVED PLANS.CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/10/2023 Processing/Technology $25.00 08/10/2023 Fire System Plan Review $426.73 08/10/2023 Fire Alarm System Permit $225.00 Total Due: $676.73 Total Payment: $0.00 Balance Due: $676.73 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5514 Permit Date: 07/31/23 Permit Type: FIRE ALARM Project Name: Mid-Mountain Materials Applicant Name: ADT Commercial LLC Applicant Address: 600 Oakesdale Ave SW Applicant, City, State, Zip: Renton, WA 98057 Contact: Marissa Rohani Phone: 206-586-6343 Email: nwcommpermits@adt.com Scope of Work: Additional work per BLD4163.Adding 10 notification devices in warehouse area Valuation: 29610.63 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: 01/27/2024 Form Permit Type: FIRE ALARM Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning M3 FINANCIAL 31051400302700 18825 67TH AVE NE MANAGEMENT Storage Warehousing& rage Services LLC Sto Contractors Contractor Primary Contact Phone Address Contractor Type License License# ADT Commercial Stephen Price 425-970-4359 600 Oaksdale Ave CONSTRUCTION COA 602 805 295 SE,Suite A CONTRACTOR ADT Commercial Stephen Price 425-970-4359 600 Oaksdale Ave CONSTRUCTION Construction ADTCOCL801 K6 SE,Suite A CONTRACTOR Contractor Plan Reviews Date Review Type Description Assigned To Review Status -5514 SYSTEM RECORD OF COMPLETION Form Completion Date:09/29/2023 Supplemental Pages Attached:01 1. PROPERTY INFORMATION Name of property: Mid Mountain Materials Address: 18825 67th Ave NE Arlington WA 98223 Description of property: manufacturing Name of property representative: Fred Willcutt Address: 18825 67th Ave NE Arlington WA 98223 Phone: 360-454-0009 Fax: 360-435-4192 E-mail: fawArnid-mountain.com 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor: ADT Commercial Address: 600 Oakesdale Ave SE Renton.WA.98057 Phone: Fax: E-mail: Service organization:ADT Commercial Address: 600 Oakesdale Ave SE Renton.WA.98057 Phone: 800-357-1808 Fax: E-mail: Testing organization: ADT Commercial Address: 600 Oakesdale Ave SE Renton WA.98057 Phone: 800-357-1808 Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: ADT Commercial Address: Phone. 800-357-1808 Fax: E-mail: Account number: STI-0017993 Phone line 1: Phone line 2: Means of transmission:cellular Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION Document Box On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: 0 New system m Modification to existing system Permit number: 4163 NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: Resideo Model number: Vista 129FRPT 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification m This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds NFPA 72(p.1 of 3) @ 2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale d1 or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized M use,contact licensing@nfpa.org. SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120vac Control panel amps: 20 Overcurrent protection: Type: breaker Amps: 20 Branch circuit disconnecting means location:South Lab Number: PNIL#AFS Rr#1 5.1.2 Secondary Power Type of secondary power:_sealed lead acid battery Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours):24 In alarm mode(minutes): 5 5.2 Control Unit 0 This system does not have power extender panels O Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line R Device Power Initiating Device R Notification Appliance R Other(specify): 7. REMOTE ANNUNCIATORS Type Location Resideo 6160CR-2 West WHSE Entry 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 1 Conventional Alarm Manual Smoke Detectors 1 Conventional Alarm Smoke Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches 2 Addressable Alarm Flow Tamper Switches 14 Addressable Supervisory Manual NFPA 72(p.2 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale 7I or distribution.No other reproduction or transmission in any form permitted wRhaut written permission of NFPA.For inquiries or to report unauthorized use,contact IicensingQnfpa.org. SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 1 Bell Visible 16 System Sensor Strobe Combination Audible and Visible 19 System Sensor Horn/Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS I] This system does not have interconnected systems. ❑ Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Greg Bjornerud Printed name: Greg B(ornerud Date: 12/14/2022 Organization:ADT Commercial Title: Foreman Phone: 206-423-2167 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Randy Chenard Printed name: Randy Chenard Date: 03/09/2023 Organization:ADT Commercial Title: Service Technician Phone: 206-255-5256 12.3 Acceptance Test Date and time of acceptance test: 03/16/2023 Installing contractor representative: Randy Chenard Testing contractor representative: Randy Chenard — Property representative: Fred Willcutt AHJ representative: NFPA 72(p.3 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized NFPA use,contact licensing@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION Form Completion Date: Number of Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property:_MA�lnuntain_MatejaLs Address: 2. SYSTEM POWER 2.1 Control Unit 2.1.1 Primary Power Input voltage of control panel: 120vac Control panel amps: 20 Overcurrent protection: Type: Breaker Amps: go Location(of primary supply panelboard): smith i ah Disconnecting means location: PNL#AES Br#12 2.1.2 Engine-Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.1.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.1.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): 2.2 In-Building Fire Emergency Voice Alarm Communications System or Mass Notification System 2.2.1 Primary Power Input voltage of EVACS or MNS panel: EVACS or MNS panel amps: Overcurrent protection: Type: Amps: Location(of primary supply panelboard): Disconnecting means location: NFPA 72(p.1 of 3) ©2016 National Fire Protection Association.This form may be copied for individual use other than for resale.it may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized arm use,contact licensing@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) 2. SYSTEM POWER (continued) 2.2.2 Engine-Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.2.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.2.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): 2.3 Notification Appliance Power Extender Panels ❑This system does not have power extender panels. 2.3.1 Primary Power Input voltage of power extender panel(s): 120vac Power extender panel amps: 20 Overcurrent protection: Type: Breaker Amps: 20 Location(of primary supply panelboard): South Lab Disconnecting means location: PNL#AES Br#12 2.3.2 Engine Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.3.3 Uninterruptible Power System Equipment powered by UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.3.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): NFPA 72(p.2 of 3) ©DO2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale L or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized NFPW use.contact Iicensinga@nfpa.org. POWER SYSTEMS SUPPLEMENTARY RECORD OF COMPLETION (continued) 2. SYSTEM POWER (continued) 2.4 Supervising Station Transmission Equipment pp This system does not use transmission equipment within the building powered by any other source than the alarm system control unit. 2.4.1 Primary Power Input voltage of shared transmission equipment: Shared transmission equipment panel amps: Overcurrent protection: Type: Amps: Location(of primary supply panelboard): Disconnecting means location: 2.4.2 Engine Driven Generator Location of generator: Location of fuel storage: Type of fuel: 2.4.3 Uninterruptible Power System Equipment powered by UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 2.4.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): In alarm mode(minutes): See Main System Record of Completion for additional information,certifications,and approvals. NFPA 72(p.3 of 3) @ 2016 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.No other reproduction or transmission in any form permitted without written permission of NFPA.For inquiries or to report unauthorized NFPX use,contact licensing@nfpa.org. Permit#: 5514 Permit Date: 07/31/23 Permit Type: FIRE ALARM Project Name: Mid-Mountain Materials Applicant Name: ADT Commercial LLC Applicant Address: 600 Oakesdale Ave SW Applicant, City, State, Zip: Renton,WA 98057 Contact: Marissa Rohani Phone: 206-586-6343 Email: nwcommpermits@adt.com Scope of Work: Additional work per BLD4163.Adding 10 notification devices in warehouse area Valuation: 29610.63 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 08/22/2023 Permit Expires: 02/18/2024 Form Permit Type: FIRE ALARM Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning M3 FINANCIAL 31051400302700 18825 67TH AVE NE MANAGEMENT Storage Warehousing& rage Services LLC Sto Contractors Contractor Primary Contact Phone Address Contractor Type License License# ADT Commercial Stephen Price 425-970-4359 600 Oaksdale Ave CONSTRUCTION COA 602 805 295 SE,Suite A CONTRACTOR ADT Commercial Stephen Price 425-970-4359 600 Oaksdale Ave CONSTRUCTION Construction ADTCOCL801K6 SE,Suite A CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Requesting 8am.Meeting 10/05/2023 FA00.FIRE ALARM Tech,Randy onsite. 11/03/2023 11/03/2023 BUILDING Approved FINAL Randy 206-255-5256 Advised of 8:15am arrival Plan Reviews Date Review Type Description Assigned To Review Status 08/03/2023 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-2 $426.73 Fire Alarm System Permit NFPA 72- 105.7.3 $225.00 Credit Card Service $20.30 Total $697.03 Attached Letters Date Letter Description 08/10/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/15/2023 XBP Conf: $676.73 151689012 08/15/2023 Amber Rush 151689012 Kristin Foster $20.30 Outstanding Balance $0.00 Notes Date Note Created By: 08/02/2023 Received hard copies Kristin Foster 07/31/2023 Waiting on application and hard copies-applicant said they are in the mail. Kristin Foster Uploaded Files Date File Name 08/22/2023 16592889-20230822 BLD5514 IssuedPermit.pdf 07/31/2023 16353403-20230731 BLD5514 Plans.pdf 07/31/2023 16353404-20230731 BLD5514 Specs.pdf