Loading...
HomeMy WebLinkAbout16419 Smokey Point Blvd_BLD5524_2026 i COMMERCIAL MECHANICAL APPLICATION • Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration 0 Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address. 16419 Smokey Point Blvd. Project Valuation: 10,000.00 Lot#: Parcel ID No.: 31052800201000 Preferred Contact: ❑ Owner O Contractor Project Description: Replace Like for Like (1) Furnace, and (1)Air Conditioner. "Please Note: Project address is for the bank, but the Furnace and AC units are for the South Tenant Space— Bayshore Concrete. Owner Name: Coastal Community Bank Office No.: 425-349-2658 sgarber@coastalbank.com Steve Garber,VP Facilities/Finance Email Address: Cell No.: Mailing Address: city: Snohomish State: WA zip. 98291 Contractor Name: D.K. Systems, Inc. Office No.: 360-755-1555 Email Address: dulce@dksystemsinc.com Cell No.: Mailing Address: PO Box 886 City: Burlington State: WA zip: 98233 L&I Contractor License Number: DKSYSI*9821_1 Expiration Date: 06/21/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 ❑ Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8" ❑ 3/4" ❑ 1" ❑ 11/2 ❑ 2" Inlet Pressure: Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit Type of Fixture No. of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Cond.Unit<_100Btu h 1 x $ 15.00 = $15.00 Air Cond.Unit>100Btu h x $ 25.00 = $ Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu/h>3hp x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods-Type II x $ 50.00 = $ Diffusers x $ 15.00 = $ Dryer Ducting x $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h 1 x $ 25.00 = $25.00 Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC <_100 Btu/h x $ 15.00 = $ Gas Fired AC >100 Btu/h x $ 25.00 = $ Gas Fired AC > 500 Btu h x $ 50.00 = $ Gas Pi in <_ 5 units x $ 15.00 = $ Gas Piping> 5 units (plus <5 units x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-Energy Recovery x $ 15.00 = $ Ventilator regulated by mechanical code,not otherwise specified Pkg.Units <_100btu x $ 25.00 = $ Pkg.Units >100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<_100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters <_ 100 Btu h x $ 15.00 = $ Unit Heaters >100 Btu h x $ 25.00 = $ VAV Boxes (Variable Air Volume,part of air x $ 10.00 = $ conditioning system) Wall Heaters - Gas Fired x $ 25.00 = $ Water Heater- Gas Fired x $ 25.00 = $ Permit Fee $40.00 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2020 Page 2 of 3 Not Applicable PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated I hereby certify that I am the❑Owner, ElApplicant, ElCon tractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. Dulce Herrera�eaa l,eao �'�`������� Dulce Herrera 8/7/23 Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of 3 7 • a —,a �� Coastal Community Bank E ' �' B shore Concrete � Alt 45 IL 110611d. —poll z -'fir. 31 i6d0 nL ILL • � 00001, _� .� „�.� 1 Coastal Go�mmunity Barik • . - Bayshore Concrete- ; Administrative Office 16419 SmokeyPoint Blvd Outside Unit SouthProject address is for the bank, but the Furnace and AC units are for the • .ce — Bayshore Concrete. Table of Contents Indoor Unit 2 Furnace 7 Outdoor AC Unit 14 Indoor Unit Outline Drawing for Upflow models:4PXCAU24BS3HAB,4PXCAU32BS3HAB,4PXCBU24BS3HAB,4PXCBU30BS3HAB,4PXCCU30BS3HAB,4PXCBU36BS3HAB, D 4PXCCU366S3HAB,4PXC6U42BS3HAB,4PXCCU42BS3HAB,4PXCBU48BS3HAB,4PXCCU48BS3HAB,4PXCDU48BS3HAB,4PXCCU60BS3HA6,4PXCDU60BS3HAB and Downflow models:4PXCBD30BS3HDB,4PXCBD36BS3HDB,4PXCCD36BS3HDB,4PXCBD42BS3HDB,4PXCCD42BS3HDB,4PXCCD60BS3HDB, 4PXCDD60BS3HDB D e 2-7/8 114 1-114 19-3/8 O O O O O O 2-1/2 A I Ccmfo 4TMcoil O II-718 p 0 1-112 -- ® o v I/4 ¢3/4 NIT L 19-I12 m 0• 3-1/2 1-3// PLUGGED SECONDARY DRAIN OPENING 21-1112 WRAPPER rf FOR VERTICAL POSITION pia/d RY DRAIN NPT rf ' PAA C FOR VERTICAL POSITION I— OPENING IN WRAPPER 0. B CD FIGURE A O C 0 4PXCBU30BS3 4PXCBU36BS3 4PXCCU36BS3 4PXCBU42BS3 4PXC 4PXCCD60 S3 4PXCDD60BS3 CU42BS3 4PXCCU60 S3 4PXCDU60BS3 0 4PXCBD30BS3 4PXCBD36BS3 4PXCCD36BS3 MODEL 4PXCAU24BS3 4PXCAU32BS3 4PXCBD42BS3 4PXCCD42BS3 4PXCDU48BS3 PXCBU24BS3 4PXCCU30BS3 4PXCBU48BS3 4PXCCU48BS3 SEE FIGURE FIGURE A FIGURE A FIGURE B FIGURE A FIGURE A FIGURE A FIGURE A FIGURE A FIGURE FIGURE A FIGURE A FIGURE B 0 0 / SHIPPING WEIGHT(LBS.) 39 43 47 54 56 61 64 68 73 77 42 49 O ^' REFRIGERANT CONTROL TXV(NON-BLEED) —• i1� HEIGHT'A"(IN.) 17-5/8 22-1/2 17-5/8 22-1/2 22-1/2 26-7/8 26-7/8 26-7/8 30-3/ 30-3/4 17-5/8 17-1/2 N r/ OVERALL WIDTH"B'(IN.) 14-1/2 14-1/2 17-112 17-1/2 21 17-1/2 21 24-1/2 21 24-1/2 17-1/2 21 O U) QOPENING WIDTH"C'(IN.) 13-5/8 13-5/8 16-5/8 16-5/8 20-1/8 16-5/8 20-1/8 23-5/8 20-1/ 23-5/8 16-5/8 20-1/8 C TOP OPENING"D" 12-3/4 12-3/4 14 15-3/4 19-1/4 15-3/4 19-1/4 22-3/4 19-11 22-3/4 15-3/4 19-1/4 GAS CONNECTION 314 7/8 314 fii—ww� v LIQUID CONNECTION 3/8 O c (NO CHED ADAPTERNACE RQUIREDTH 14-1/2 14-1/2 17-1/2 17-1/2 21 17-1/2 21 24-1/2 21 24-112 17-1/2 21 C (NO ADAPTER RQUIRED) DRAIN PAN PLASTIC rf From Dwg D346711 RevB �• r+ m > N 0 0 co co 0 0 E 2 �o Li Qo 0 o� 0 � > 3 O o v= m ml Lu 0 0 0 (D LLi -i- 0 0 0 - o a � p o o 0 - 0 1 t � 0 u a PRODUCT SPECIFICATIONS[']--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED UPFLOW COMFORT TM COILS[21 Model 4PXCAU24BS3HAB 4PXCAU32BS3HAB 4PXCBU24BS3HAB 4PXCBU30BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-2.0 1.5-3.0 1.5-2.0 1.5-3.0 Rows/F.P.I. 2/20 2/20 2/20 3/14 Face Area(sq.ft.) 3.0 4.5 3.0 3.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size -Gas(in.) 3/4 3/4 3/4 3/4 Line Size -Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 17.5 x 26.5 26.35 x 17.5 x 26.5 21.35 x 20.5 x 26.5 21.35 x 20.5 x 26.5 Uncrated 17.6 x 14.5 x 21.5 22.6 x 14.5 x 21.5 17.6 x 17.5 x 21.5 17.6 x 17.5 x 21.5 WEIGHT(lbs) Shipping-- Net 39/31 43/35 42/34 47/39 2 4PXCV-SUB-4A-EN Model 4PXCCU30BS3HAB 4PXCBU36BS3HAB 4PXCCU36BS3HAB 4PXCBU42BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/F.P.I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 24 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x21x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 49/41 54/46 56/48 61 /53 Model 4PXCCU42BS3HAB 4PXCBU48BS3HAB 4PXCCU48BS3HAB 4PXCDU48BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 2.0-4.0 3.0-5.0 3.0-5.0 Rows/F.P.I. 3/14 3/14 3/14 3/14 Face Area(sq.ft.) 5.5 6.0 6.0 6.0 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 30.65 x 24 x 26.5 30.65 x 20.5 x 26.5 30.65 x 24 x 26.5 30.65 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 26.9 x 17.5 x 21.5 26.9x21 x21.5 26.9 x 24.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 64/56 61 /53 64/56 68/60 Model 4PXCCU60BS3HAB 4PXCDU60BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN Cooling Capacity(Tons) 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/12 3/12 Face Area(sq.ft.) 6.0 6.0 Tube Size 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Drain Conn.Size (in.) 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing REFRIGERANT R-410A R-410A CONNECTIONS BRAZED BRAZED Line Size Gas (in.) 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D Crated (H x W x D) 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 30.7 x 21 x 21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping -- Net 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps (A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Left with Kit 4PXCV-SUB-4A-EN 3 PRODUCT SPECIFICATIONSM --4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED DOWNFLOW COMFORT TM COILS [21 Model 4PXCBD30BS3HDB 4PXCBD36BS3HDB 4PXCCD36BS3HDB 4PXCBD42BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/FIR I. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21.35 x 20.5 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x17.5x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) 47/39 Shipping-- Net 54/46 56/48 61 /53 Model 4PXCCD42BS3HDB 4PXCCD60BS3HDB 4PXCDD60BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/14 3/12 3/12 Face Area(sq.ft.) 5.5 6.0 6.0 Tube Size 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D Crated (H x W x D) 30.65 x 24 x 26.5 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 30.7x21 x21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping-- Net 64/56 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Right with Kit 4 4PXCV-SUB-4A-EN PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(SCFM)VS. PRESSURE DROP ACROSS WET COIL PRESSURE DROP (INCHES OF WATER COLUMN) MODEL 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4PXCAU24BS3HAB 340 430 510 585 650 715 775 4PXCAU32BS3HAB 570 725 860 985 1100 1200 1305 4PXCBD30BS3HDB 510 645 760 865 965 1055 1140 4PXCBD36BS3HDB 645 810 950 1080 1200 1305 1410 4PXCBD42BS3HDB 585 745 880 1000 1115 1220 1315 4PXCBU24BS3HAB 435 555 660 755 840 920 995 4PXCBU30BS3HAB 525 665 1790 900 1000 1095 1180 4PXCBU36BS3HAB 655 825 970 1100 1220 1330 1435 4PXCBU42BS3HAB 625 790 935 1065 1185 1295 1400 4PXCBU48BS3HAB 640 815 965 1095 1220 1335 1445 4PXCCD36BS3HDB 760 955 1125 1275 1415 1540 1665 4PXCCD42BS3HDB 695 880 1040 1185 1315 1440 1555 4PXCCD60BS3HDB 720 920 1095 1250 1390 1525 1655 4PXCCU30BS3HAB 540 680 805 920 1020 1120 1210 4PXCCU36BS3HAB 770 970 1145 1300 1440 1570 1696 4PXCCU42BS3HAB 735 930 1105 1255 1400 1530 1655 4PXCCU48BS3HAB 760 965 1140 1300 1445 1580 1710 4PXCCU60BS3HAB 740 940 1120 1280 1425 1565 1695 4PXCDD60BS3HDB 815 1040 1235 1410 1575 1725 1870 4PXCDU48BS3HAB 870 1100 1300 1485 1650 1805 1950 4PXCDU60BS3HAB 835 1065 1265 1 1445 1615 1770 1915 Mechanical Specifications General These coils are A.H.R.I.certified with Trane The dedicated Upflow and Downflow coils are designed for cooling and heat pump and American Standard's applications. The coil uses 3/8" seamless aluminum tubing mechanically bonded to matching condensing units. aluminum plate fin. Accessories Refrigerant for the PXC is controlled with a factory installed Non-Bleed TXV Evaporator Defrost Control installed on coil refrigerant control. Refrigerant connections are brazed fittings. for lower ambient operating The coil cabinet has a removable front and interior access panel for evaporator coil conditions. entering air surface cleaning. Upflow coils can be converted to horzontal left and downflow coils can be converted to horizontal right with optional kit purchased separately. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4PXCV-SUB-4A-EN 29 Apr 2021 Supersedes (New) 02021 Furnace Submittal Upflow / Horizontal Left/Right Single Stage Condensing Gas Fired Furnace 120,000 BTU H , Convertible to Horizontal Horizontal Right or Horizontal Left S9X1D120U5PSBA S9131 D120U5PSAA o � • o Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July2019 S9X1 D120U-SUB-1A-EN 4fR"IngersollRand Outline Drawings Table 1. 24.5" Upf low Cabinet IN j g - =r _WQ - + + + + 0 0= =a _Wa , m� _ g -- - aN 2 S9X1 D120U-SUB-1A-EN Product Specifications MODEL S9X1D120USPSBA(a) MODEL S9X1D120USPSBA(a) S9B1D120USPSAA S9B1D120USPSAA TYPE Upflow/Horizontal Gauge(Fired) 20 RATINGS(b) ORIFICES—Main Input BTUH 120,000 Nat.Gas Qty.—Drill Size 6-45 Capacity BTUH(ICS)(C)(d) 116,400 LP Gas Qty.—Drill Size 6-56 Temp.Rise(Min.-Max.) 40-70 GAS VALVE Redundant-One Stage AFUE(%)S9X1/S9B1(d) 95.0/92.1 PILOT SAFETY DEVICE BLOWER DRIVE DIRECT Type 120 V SiNi Igniter Diameter—Width(In.) 11 X 10 BURNERS—Type Multiport Inshot No.Used 1 Number 6 Speeds(No.)(e) 9 POWER CONN.—V/Ph/Hz(h) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(In Amps) 14.1 Table Motor HP 1 Max.Overcurrent Protection(Amps) 15 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS H x W x D FLA 10.6 Uncrated(In.) 34 x 24-1/2 x 28-3/4 COMBUSTION FAN—Type Centrifugal Crated(In.) 35-1/2 x 26-1/2 x 30-7/8 Drive—No.Speeds Direct-1 WEIGHT Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 167/156 (a) Meets Energy Star Volts/Ph/Hz 120/1/60 b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 0.66 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are FILTER—Furnished? No up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. Type recommended High Velocity Central Furnace heating designs are certified to ANSI Z21.47/CSA Hi Vel.(No. Size Thk.) 1—24x25—1 in. 2.3. (d) Based on U.S.government standard tests. VENT PIPE DIAMETER—Min(in.) 3 Round (e) 9 Speed constant torque ECM blower motor M(9) M Refer to the Vent Length Table in the Installer's Guide. HEAT EXCHANGER (9) All furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Type—Fired 409 Stainless Steel Electrical Code;however,installations must comply with local codes. —Unfired 29-4C Stainless Steel S9X1 D120U-SUB-1A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 707 443 179 - - Watts 46 55 64 - - 2 SUM 1344 1218 1092 966 840 Watts 163 183 202 222 241 3 SCFM 1532 1419 1307 1195 1083 Watts 225 247 268 290 312 4 SUM 1584 1477 1370 1263 1156 Watts 247 270 292 315 338 S9X1D120U5PSBA 5 SUM 1915 1818 1722 1625 1529 S9B1D120USPSAA Watts 401 428 454 480 506 6 SUM 2104 2016 1927 1839 1750 Watts 525 553 582 610 639 7 SUM 2132 2045 1958 1870 1783 Watts 546 575 604 633 662 8 SUM 2410 2328 2247 2165 2084 Watts 833 868 903 937 972 9 SUM 2472 2401 2329 2257 2186 Watts 909 944 979 1013 1048 CFM Versus Temperature Rise Table 2. Heating Table — Upflow CFM VS.TEMPERATURE RISE MODEL 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1D120U5PSBA 67 65 60 55 54 51 48 44 41 S9B1D120U5PSAA 4 S9X1 D1 20U-SUB-1A-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the S9X1 Furnace is certified by the manufacturer to leak American Gas Association for both natural and L.P. 1%(1.4%for S9131)or less of nominal air conditioning gas. Limit setting and rating data were established and CFM delivered when pressurized to.5"water column approved under standard rating conditions using with all inlets,outlets,and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4CT"'stainless steel secondary heat exchanger to reclaim Durable,cycle tested, heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and Heavy gauge steel and "wrap-around"cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty. Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat. Complete front service access. valve,flame control and includes self diagnostics for a. Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. S9M D120U-SUB-1A-EN 5 Features and Benefits UP TO 96.0%AFUE ON S9X1 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections; no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34 INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 6 SKU's — Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's — Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement, regardless of poise All models are airtight; 1%or less air leakage as per THREE—WAY MULTI-POISE (UPFLOW, ASHRAE 193 0.4%for S9131) HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install (no conversion kits required) Widths are industry standard: 17.5",21",and 24.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2" pipe can be used up to 100K 6 SM1 D120U-SUB-1A-EN 4j:Pingersoll Rand© Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club CarT), Ingersoll RandID, Thermo Kingg and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. 4$Vingersoll Rand Tr THERMO KING TRANE® ingersollrand.com m C Eta �s ril7i.71Y13 Mi. Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X1D120U-SUB-1A-EN 24Jul2019 Supersedes(New) ©2019 Ingersoll Rand 0 TR E° Outdoor AC Unit Submittal Split System Cooling 4TTR406ON1000A 4TTR406ON1000B Note: "Graphics in this document are for representation only.Actual model may differ in appearance." October2022 4TTR406ON-SUB-1 B-EN T � n N = TECH NO LOG I ES' 0 TRAKE® B C i SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 152A (5 FEET) ABOVE UNIT, UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL K 25 (1 A 22.2 (1/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA, K.O. WITH 22.2 (7/8) DIA, HOLE IN CONTROL BON BOTTOM FOR ELECTRICAL POWER SUPPLY H F II III I L J K.O. FOR ALTERNATE G ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, "E' I,D. FEMALE BRAZE -7 CONNECTION WITH I/4" SAE GAS LINE 114 TURN BALL SERVICE VALVE, "D" FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH I/4" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 47TR4060N 4 1147 946 870 7/8 3/8 152 98 219 86 508 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power[dB] Model Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR4060N 72 81 75 71 70 68 63 58 53 Note:Rated in accordance with AHRI Standard 270-2008*For reference only 2 4TTR406ON-SUB-1 B-EN 0 TRANS° Product Specifications OUTDOOR UNIT(a)(b) 4TTR4060N 1000A 4TTR4060N1000B POWER CONNS.—V/PH/HZ W 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 28 34 BR.CIR.PROT RTG.—MAX.(AMPS) 50 60 COMPRESSOR CLIMATUFFO-SCROLL CLIMATUFF@-SCROLL NO.USED—NO.STAGES 1—1 1—1 VOLTS/PH/HZ 208/230/1/60 208/230/1/60 R.L.AMPS(d)—L.R.AMPS 21.9—118.7 26.3—140.6 FACTORY INSTALLED START COMPONENTS(e) NO(Uses BAYKSKT263) NO(Uses BAYKSKT263) INSULATION/SOUND BLANKET NO NO COMPRESSOR HEAT NO NO OUTDOOR FAN PROPELLER PROPELLER DIA.(IN.)—NO.USED 27.5—1 27.5—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 DIRECT—1 CFM @ 0.0IN.W.G.M 5230 5230 NO.MOTORS—HP 1-1/5 1-1/5 MOTOR SPEED R.P.M. 850 850 VOLTS/PH/HZ 208/230/1/60 208/230/1/60 F.L.AMPS 0.97 0.97 OUTDOOR COIL—TYPE SPINE FIN TM SPINE FIN TM ROWS—F.P.I. 1-24 1-24 FACE AREA(SQ.FT) 30.8 30.8 TUBE SIZE(IN.) 3/8 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(e) 9 LBS.,8 OZ 9 LBS.,8 OZ FACTORY SUPPLIED YES YES LINE SIZE—IN.O.D.GAS(h) 1-1/8 1-1/8 LINE SIZE—IN.O.D.LIQ. 3/8 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F 10°F DIMENSIONS HXWXD HXWXD CRATED(IN.) 50.4 x 35.1 x 38.7 50.4 x 35.1 x 38.7 WEIGHT SHIPPING(LBS.) 302 302 NET(LBS.) 277 277 (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment ce standard 210/240. (b) Rated in accordance with AHRI standard 270. (_) Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers orfuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size.The value shown is the branch circuit selection current. (e) Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor start.No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter.Optional kit shown. (f) Standard Air—Dry Coil—Outdoor (9) This value approximate.For more precise value see unit nameplate. (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid 60 ft.For greater length consult refrigerant piping software Pub.No.32-3312-0*(* denotes latest revision). 4TTR406ON-SUB-1 B-EN 3 0 TRANE® Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection. Other features include: Centrifugal unit,ten (10)feet of tested connecting line,and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match.This unit Condenser Coil is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer.The coil is protected on all four furnace coils that are AHRI certified.The unit is certified sides by louvered panels. to UL 1995. Exterior is designed for outdoor Low Ambient Cooling application. As manufactured,this system has a cooling capacity to Casing 55°F.The addition of an evaporator defrost control Unit casing is constructed of heavy gauge,galvanized permits operation to 40°F.The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish.The corner panels are prepainted.All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over).Sub-base to match switches.A factory supplied,field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 4TTR406ON-SUB-1 B-EN TRAME® Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. As • Unitary Small AC AHRI Standard 210/240 1 C Certification applies only anthen the co,plele syste, UL US LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4TTR4060N-SUB-1B-EN 280ct2o22 Supersedes 4TTR4060N-SUB-1A-EN (March 2022) ©2022 Trane Table of Contents Indoor Unit 2 Furnace 7 Outdoor AC Unit 14 IL ��. CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE BY -v/ NO C ANGES AUTHORIZED UNLESS APPRC\'FD BY THE BUILDING INSPECTOR M�y� Rece ..�. AUG 0 7 2023 Indoor Unit Outkne Drawtrva for Upflawmodets.4PXCAU24BS3HA8,4PXCAU32BS3HA8,4PXC8U24BS3HA8.4PXCBU30BS3KA8,4PXCCU30BS3HAB.4PXC8U368S3HA0. D 4PXCCU368S3HAB,4PXC8Ua28S3HA8,4PXCCW12BS3HAB,4PXC6U488S3HA8,4PXCCUa88S3HA8.4PXCDU48BS3HAB,4PXCCU60BS3HAB,4PXCDU60BS3HAS and DownllDw models 4PXC8VJWS3HDB.4PXCBD36BS3HD8,4PXCC030DG31 IDD,4PXC80428S38D8,4PXCCD426S3HD8.4PXCrr)F 08S3HD8, 4PXCOD608S3HOS r p I1 A Camfor6RCoil O I b V P A n 1 g., 0 M _ o a X\ 6.4 L I Cr fD B FIGURE A C O 4P%CBU30B53 4P%CBU36B53 4P%CCU36B53 4PXCBU42BG3 4PXCOU42BS3 IS 3 4P%COU60353 MODEL 4P%CAV240G3 4PXCAU32B53 4PXCBQ420SR 4P%CC042353 4PX0004BB53 4P%CCU33053 4P%CBD30B33 4P%CBD33033 4PXLC03fiB53 4PXCBU48B53 4PXCCU4BBSi 4PXGDD603$3 T GEE FIGURE FIGURER FIGUREA FIOUREB FIGUREA FIGUREA FIGUREA FIpUREA FIGURE i(1{F! FIGUREA FIGUREA FIGURER 0 I� SNIPPING WEIGHT(LES)♦I. 38 43 t.�llt!.!� ! N 61 64 N ]3 ]] 42 `+48 � 0 < REFRIGERANT LOMROL T%V(NON BLEED) . HEIGHT75 Y/ OVERALL WIOTH'B'IINI N�12 14.12 \l.lp if-12 ]! tr-Il> �1' 24-12 21 24 12 1] 12 0 CD CCIO OPENING WIDTH'C'(IN) t3.52 13-y3 1I.>w 1fi y0� 12 tfi-y0 I 20-1/3 23-513 !1 23GB IBy3 2a 212 Q ■ TOPOPENING-D' 12 y4 12-y4 is yw 15 ya .1P, 13 y4 1B-1/4 22 y4 \�1 22 ya V`y9 >� ii rF GAS CONNECTION y4 ]R LIQUID CONNECTION 0 'W IND CHED ADAPTER WIDTH /<•\2 14•12, 17-12 Q.\IA 21 ] 12 2t 24-12 21 24-t2 17 12 21 3 INO AOAPTEq ROUIgEO) GRAIN PAN — IPA ► .N11 PLASTIC From Dwg D346711 RevB 3 �• ' m a� m O Oto - I v M ❑ o) 3 E 2 �o U- <o 0 o� 0 > 3 �60 _ p O CRC -�- O - O ® a U 0 0 0 PRODUCT SPECIFICATIONS']--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED UPFLOW COMFORT TM COILS 121 Model 4PXCAU24BS3HAB 4PXCAU32BS3HAB 4PXCBU24BS3HAB 4PXCBU30BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-2.0 1.5-3.0 1.5-2.0 1.5-3.0 Rows/F.P.I. 2/20 2/20 2/20 3/14 Face Area(sci t.) 3.0 4.5 3.0 3.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size--Gas(in.) 3/4 3/4 3/4 3/4 Line Size--Liquid (in) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 21.35 x 17.5 x 26.5 26.35 x 17.5 x 26.5 21.35 x 20.5 x 26.5 21.35 x 20.5 x 26.5 Uncrated 17.6 x 14.5 x 21.5 22.6 x 14.5 x 21.5 17.6 x 17.5 x 21.5 17.6 x 17.5 x 21.5 WEIGHT(lbs) Shipping--Net 39/31 43/35 42/34 47/39 2 4PXCV-SUB-4A-EN Model 4PXCCU30BS3HAB 4PXCBU36BS3HAB 4PXCCU36BS3HAB 4PXCBU42BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/FRI. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT _Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size--Gas(in.) 3/4 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 21.35 x 24 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6x21x21.5 22.6 x 17.5 x 21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) Shipping--Net 49/41 54/46 56/48 61 /53 Model 4PXCCU42BS3HAB 4PXCBU48BS3HAB 4PXCCU48BS3HAB 4PXCDU48BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 2.0-4.0 3.0-5.0 3.0-5.0 Rows/F.P.I. 3/14 3/14 3/14 3/14 Face Area(sq.ft.) 5.5 6.0 6.0 6.0 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size--Gas(in.) 7/8 7/8 7/8 7/8 Line Size- Liquid(in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H XWX D Crated(H x W x D) 30.65 x 24 x 26.5 30.65 x 20.5 x 26.5 30.65 x 24 x 26.5 30.65 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 26.9 x 17.5 x 21.5 26.9x21 x21.5 26.9 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 64/56 61 /53 64/56 68/60 Model 4PXCCU60BS3HAB 4PXCDU60BS3HAB INDOOR COIL--Type PLATE FIN PLATE FIN Cooling Capacity(Tons) 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/12 3/12 Face Area(sq.ft.) 6.0 6.0 Tube Size 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing REFRIGERANT R-410A R-410A CONNECTIONS BRAZED BRAZED Line Size--Gas(in.) 7/8 7/8 Line Size Liquid in. 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D Crated(H x W x D) 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 30.7 x 21 x 21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 73/65 77/69 [1]These indoor Coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Left with Kit 4PXCV-SUB-4A-EN 3 PRODUCT SPECIFICATIONSM--4PXC- SPLIT SYSTEM HEAT PUMP/COOLING CASED DEDICATED DOWNFLOW COMFORTT- COILS 123 Model 4PXCBD30BS3HDB 4PXCBD36BS3HDB 4PXCCD36BS3HDB 4PXCBD42BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 1.5-3.0 2.0-3.5 2.0-4.0 2.0-3.5 Rows/FRI. 3/14 3/12 3/12 3/14 Face Area(sq.ft.) 3.5 5.0 5.0 5.5 Tube Size 3/8 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED Line Size--Gas(in.) 3/4 7/8 7/8 7/8 Line Size -Liquid in.) 3/8 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D HXWXD Crated(H x W x D) 21.35 x 20.5 x 26.5 26.35 x 20.5 x 26.5 26.35 x 24 x 26.5 30.65 x 20.5 x 26.5 Uncrated 17.6 x 17.5 x 21.5 22.6x17.5x21.5 22.6x21x21.5 26.9 x 17.5 x 21.5 WEIGHT(Ibs) 47/39 Shippin --Net 54/46 56/48 61 /53 Model 4PXCCD42BS3HDB 4PXCCD60BS3HDB 4PXCDD60BS3HDB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN Cooling Capacity(Tons) 2.5-3.5 3.5-5.0 3.5-5.0 Rows/F.P.I. 3/14 3/12 3/12 Face Area(sq.ft.) 5.5 6.0 6.0 Tube Size 3/8 3/8 3/8 Refrigerant Control Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Internal check valve Yes Yes Yes Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See outline drawing See outline drawing See outline drawing REFRIGERANT R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED Line Size Gas(in.) 7/8 7/8 7/8 Line Size Liquid (in) 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D Crated(H x W x D) 30.65 x 24 x 26.5 34.45 x 24 x 26.5 34.45 x 27.5 x 26.5 Uncrated 26.9x21 x21.5 30.7x21 x21.5 30.7 x 24.5 x 21.5 WEIGHT(Ibs) Shipping--Net 64/56 73/65 77/69 [1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps (A.H.R.I.Standard 210/240) Refer to the Split System Outdoor product information site or www.ahrinet.org [2]Convertible to Horizontal Right with Kit 4PXCV-SUB-4A-EN 4 PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(SCFM)VS. PRESSURE DROP ACROSS WET COIL PRESSURE DROP(INCHES OF WATER COLUMN) MODEL 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4PXCAU24BS3HAB 340 430 510 585 650 715 775 4PXCAU32BS3HAB 570 725 860 985 1100 1200 1305 4PXCBD30BS3HDB 510 645 760 865 965 1055 1140 4PXCBD36BS3HDB 645 810 950 1080 1200 1305 1 1410 4PXCBD42BS3HDB 585 745 880 1000 1115 1220 1315 4PXCBU24BS3HAB 435 555 660 755 840 920 995 4PXCBU30BS3HAB 525 665 790 900 1000 1095 1180 4PXCBU36BS3HAB 655 825 970 1100 1220 1330 1435 4PXCBU42BS3HAB 625 790 935 1065 1185 1295 1400 4PXCBU48BS3HAB 640 815 965 1095 1220 1335 1445 4PXCCD36BS3HDB 760 955 1125 1275 1415 1540 1665 4PXCCD42BS3HDB 695 880 1040 1185 1315 1440 1555 4PXCCD60BS3HDB 720 920 1095 1250 1390 1525 1655 4PXCCU30BS3HAB 540 680 805 920 1020 1120 1210 4PXCCU36BS3HAB 770 970 1145 1300 1440 1570 1696 4PXCCU42BS3HAB 735 930 1105 1255 1400 1530 1655 4PXCCU48BS3HAB 760 965 1140 1300 1445 1580 1710 4PXCCU60BS3HAB 740 940 1120 1280 1425 1565 1695 4PXCDD60BS3HDB 815 1040 1235 1410 1575 1725 1870 4PXCDU48BS3HAB 870 1100 1300 1485 1650 1805 1950 4PXCDU60BS3HAB 835 1065 1265 1 1445 1615 1770 1 1915 Mechanical Specifications General These coils are A.H.R.I.certified with Trane The dedicated Upflow and Downflow coils are designed for cooling and heat pump and American Standard's applications. The coil uses 3/8"seamless aluminum tubing mechanically bonded to matching condensing units. aluminum plate fin. Accessories Refrigerant for the PXC is controlled with a factory installed Non-Bleed TXV Evaporator Defrost Control installed on coil refrigerant control. Refrigerant connections are brazed fittings. for lower ambient operating The coil cabinet has a removable front and interior access panel for evaporator coil conditions. entering air surface cleaning. Upflow coils can be converted to horzontal left and downflow coils can be converted to horizontal right with optional kit purchased separately. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are commicfed la using environmentally conscious print practices. 4PXCV-SU8-4A-EN 29 Apr 2021 Supersedes (New) 02021 Furnace Submittal Upflow / Horizontal Left/Right Single Stage Condensing Gas Fired Furnace 120,000 BTU H Upflow,Convertible to Horizontal Right or Horizontal Left ' v S9X1D120U5PSBA S9B1 D120U5PSAA % RR o I Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July 2019 S9X1 D 120U-SUB-1 A-E N LR7lnyersvllRand Outline Drawings Table 1. 24.5"Upflow Cabinet S�� 3k±k A ak :y3 2 o=� -T—I—T _ e=n T } HWQ a:� o - ..6 2 S9X1 D120U-SUB-1 A-EN Product Specifications MODEL S9X1D120USPSBA(a) MODEL S9X1D120USPSBA(a) S9B1D120USPSAA S98ID12OUSPSAA TYPE Upflow/Horizontal Gauge(Fired) 20 RATINGS(b) ORIFICES—Main Input BTUH 120,000 Nat.Gas Qty.—Drill Size 6-45 Capacity BTUH(ICS)(c)(d) 116,400 LP Gas Qty.—Drill Size 6-56 Temp.Rise(Min.-Max.) 40-70 GAS VALVE Redundant-One Stage AFUE(%)S9X1/S9B1(d) 95.0/92.1 PILOT SAFETY DEVICE BLOWER DRIVE DIRECT Type 120 V SiNi Igniter Diameter—Width(In.) 11 X 10 BURNERS—Type Multiport Inshot No.Used 1 Number 6 Speeds(No.)(e) 9 POWER CONN.—V/Ph/Hz(h) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(In Amps) 14.1 Table Max.Overcurrent Protection(Amps) 15 Motor HP 1 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS H x W x D FLA 10.6 Uncrated(In.) 34 x 24-1/2 x 28-3/4 COMBUSTION FAN—Type Centrifugal Crated(In.) 35-1/2 x 26-1/2 x 30-7/8 Drive—No.Speeds Direct-1 WEIGHT Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 167/156 120/1/60 (a) Meets Energy Star Volts/Ph/Hz (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 0.66 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are FILTER—Furnished? No up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. Type recommended High Velocity (_) Central Furnace heating designs are certified to ANSI Z21.47/CSA Hi Vel.(No.-Size-Thk.) 1—24x25—1 in. 2.3. (d) Based on U.S.government standard tests. VENT PIPE DIAMETER—Min(in.) 3 Round 0) 9 Speed constant torque ECM blower motor M(g) M Referto the Vent Length Table in the Installer's Guide. HEAT EXCHANGER e) All furnace models have a vent outlet diameter that equals 2 in. (hl The above wiring specifications are in accordance with National Type—Fired 409 Stainless Steel Electrical Code;however,installations must comply with local codes. —Unfired 29-4C Stainless Steel S9X1 D120U-SU13-1 A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 707 443 179 - - Watts 46 55 64 - 2 SCFM 1344 1218 1092 966 840 Watts 163 183 202 222 241 3 SCFM 1532 1419 1307 1195 1083 Watts 225 247 268 290 312 4 SCFM 1584 1477 1370 1263 1156 Watts 247 2/0 292 115 338 S9X1D120U5PSBA 5 SCFM 1915 1818 1722 1625 1529 59131D120USPSAA Watts 401 428 454 480 506 6 SCFM 2104 2016 1927 1839 1750 Watts 525 553 582 610 639 7 SCFM 2132 2045 1958 1870 1783 Watts 546 575 604 633 662 8 SCFM 2410 2328 2247 2165 2084 Watts 833 868 903 937 972 9 SCFM 2472 2401 2329 2257 1 2186 Watts 909 944 979 1013 1048 CFM Versus Temperature Rise Table 2. Heating Table— Upflow CFM VS.TEMPERATURE RISE MODEL 1100 1200 1300 1 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1D120U5PSBA 67 65 60 55 54 51 1 48 44 41 S9B1D120U5PSAA 4 SMI D120U-SUB-1 A-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the S9X1 Furnace is certified by the manufacturer to leak American Gas Association for both natural and L.P. 1%(1.4%for S9B1)or less of nominal air conditioning gas. Limit setting and rating data were established and CFM delivered when pressurized to.5"water column approved under standard rating conditions using with all inlets,outlets,and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. The S-Series furnace has a special type 29-4CT"" QUICK HEATING stainless steel secondary heat exchanger to reclaim Durable,cycle tested, heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure. Low Heavy gauge steel and "wrap-around"cabinet energy power vent blower,to increase efficiency and construction is used in the cabinet with baked-on provide a positive discharge of gas fumes to the enamel finish for strength and beauty.Every outside. orientation has at least two venting options.There are BURNERS no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. The S-Series furnace utilizes a Silicon Nitride Hot gas with LP conversion kit. Surface Ignition system,which eliminates the waste of INTEGRATED SYSTEM CONTROL a constant burning pilot.The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat. Complete front service access. valve,flame control and includes self diagnostics for a.Low energy power venter ease of service.Also contains dry contacts for EAC and b.Vent proving pressure switches. HUM. 5 S9X1 D120U-SUB-1A-EN Features and Benefits UP TO 96.0%AFUE ON S9X1 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections;no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT Works great with larger,high-efficiency coils EXCHANGER Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3—WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 6 SKU's — Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 5 SKU's — Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CFM/ton REGULATORY Blower deck has full-length rails for easy removal and replacement,regardless of poise All models are airtight;1%or less air leakage as per THREE—WAY MULTI-POISE(UPFLOW, ASHRAE 193(1.4%for S9B1) HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED Open vestibule design provides a full 34" high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install(no conversion kits required) Widths are industry standard: 17.5",21",and 24.5" Every model has at least two venting options Depth remains approximately 28" When in horizontal,trap extends only about 2" Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as,other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup/Status/Diagnostics/Digital Display Vent table improvements including longer vent No dip switches lengths;2" pipe can be used up to 100K 6 S9X1 D120U-SUB-1 A-EN Ingersoll Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. �® I'f/ingersoll Rand THERMO KING T/�M/E' ingersollrand.com c(%us (� Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X1 D120U-SUB-1A-EN 24 Jul 201s ©2019 Ingersoll Rand Supersedes(New) 0 TIPME® Outdoor AC Unit Submittal Split System Cooling 4TTR406ON1000A 4TTR406ON1000B r Note:"Graphics in this document are for representation only.Actual model may differ in appearance." October 2022 4TTR4060N-SUB-1 B-EN 1 R ^ N = TECH NO LOG I ES' AM TRANE° B C SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNII UNIT SHOULD 8E PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 30$412.1 FROM WALL AND ALL SURROUNDING SHRU88EIY ON TWO SIDES OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL NK 25 111 A 22 2 (7/BI DIA HOLE LOW VOLTAGE 28.6 (1-1/8) CIA N.O. WITH 22 2 I7/81 DIA HOLE IN CONTROL BOA BOTTOM FOR ELECTRICAL POWER SUPPLY R I F K.O. FOR ALTERNATE (; ELECTRICAL ROUTING LIQUD LINE SERVICE VALVE. 'E' I D iEMALI BRAZE GAS LINE 114 TURN BALL SERVICE VALVE, -D- CONNECTION WITH 114' SAE I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTINGS. FLARE PRESSURE TAP FITTING Model Base A B C D E F G H ] K 1147 946 870 7/8 3/8 152 98 219 86 508 4TTR4060N 4 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power[dB] Model Power Level[dB(A)] 63 Hz* 125 Hz 25EU 500 Hz 1 000 Hz 2000 Hz F 4000 Hz 8000 Hz 4TTR406ON 72 81 75 71 70 68 63 58 53 Note:Rated in accordance with AHRI Standard 270-2008*For reference only 4TTR4060N-SUB-1 B-EN 2 1WTAME Product Specifications OUTDOOR UNIT(el(b) 4TTR4060N 1000A 4TTR406ON1000B POWER CONNS.—V/PH/HZ W 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 28 34 BR.CIR.PROT.RTG.—MAX.(AMPS) 50 60 COMPRESSOR CLIMATUFF@-SCROLL CLIMATUFF@-SCROLL NO.USED—NO.STAGES 1—1 1—1 VOLTS/PH/HZ 208/230/1/60 208/230/1/60 R.L.AMPS(d)—L.R.AMPS 21.9—118.7 26.3—140.6 FACTORY INSTALLED START COMPONENTS(e) NO(Uses BAYKSKT263) NO(Uses BAYKSKT263) INSULATION/SOUND BLANKET NO NO COMPRESSOR HEAT NO NO OUTDOOR FAN PROPELLER PROPELLER DIA.(IN.)—NO.USED 27.5—1 27.5—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 DIRECT—1 CFM @ 0.0 IN.W.G.M 5230 5230 NO.MOTORS—HP 1-1/5 1-1/5 MOTOR SPEED R.P.M. 850 850 VOLTS/PH/HZ 208/230/1/60 208/230/1/60 F.L.AMPS 0.97 0.97 OUTDOOR COIL—TYPE SPINE FINTM SPINE FINT ROWS—F.P.I. 1-24 1-24 FACE AREA(SQ.FT.) 30.8 30.8 TUBE SIZE(IN.) 3/8 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 9 LBS.,8 OZ 9 LBS.,8 OZ FACTORY SUPPLIED YES YES LINE SIZE—IN.O.D.GAS(h) 1-1/8 1-1/8 LINE SIZE—IN.O.D.LIQ. 3/8 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F 10°F DIMENSIONS H X W X D H X W X D CRATED(IN.) 50.4 x 35.1 x 38.7 50.4 x 35.1 x 38.7 WEIGHT SHIPPING(LBS.) 302 302 NET(LBS.) 277 277 (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment to standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size.The value shown is the branch circuit selection current. M Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor start.No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter.Optional kit shown. (f) Standard Air—Dry Coil—Outdoor (9) This value approximate.For more precise value see unit nameplate. (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid 60 ft.For greater length consult refrigerant piping software Pub.No.32-3312-0*(* denotes latest revision). 4TTR406ON-SUB-1 B-EN 3 0 . Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection.Other features include:Centrifugal unit,ten(10)feet of tested connecting line,and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match.This unit Condenser Coil is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified sides by louvered panels. to UL 1995.Exterior is designed for outdoor Low Ambient Cooling application. As manufactured,this system has a cooling capacity to Casing 55°F.The addition of an evaporator defrost control Unit casing is constructed of heavy gauge,galvanized permits operation to 40°F.The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish.The corner panels are prepainted.All ambient cooling to 30°F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling(manual compressor contactor and low and high pressure and automatic change over).Sub-base to match switches.Afactory supplied,field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 4TTR4060N-SUB-1 B-EN 0 TR4AW Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. Unitary Small AG AHRI Standard 210/240 C UL US LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4TTR4060N-SUB-1 B-EN 2e oct 2022 Supersedes 4TTR4060N-SUB-IA-EN (March2022) ©2022Trane CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 16419 SMOKEY POINT BLVD Permit#: 5524 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052800201000 DATE OF ISSUANCE. Scope of Work:Replace Like for Like(1)Furnace and(1)Air Conditioner Valuation: 10000.00 OWNER APPLICANT CONTRACTOR COASTAL COMMUNITY BANK D.K. Systems,Inc D.K. Systems,Inc 10520 19TH AVE SE PO Box 886,PO Box 886 962 S Spruce Street EVERETT,WA 98208-4276 Burlington Burlington,WA 98233 360-755-1555 360-755-1555 LIC:602 204 164 EXP:05/31/2024 LIC:DKSYSI*982L1 EXP:06/21/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR D.K. Systems,Inc 962 S Spruce Street Burlington,WA 98233 360-755-1555 LIC#:DKSYSI*982L1 EXP: 06/21/2024 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: CODE YEAR: 2018 STORIES: 1 CONST.TYPE: 111B DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC I I O/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Dgirelly signed Ey DNS Herrera DN:C=US,OWPrei—Coordinabr.C= K.Systems,Inc.', / N=Dolts Henea,E=duke®dksyslemalnc.com Dulce HerreraRPB�rtlamtkeearen.a..'—mem -�'' �/�� 08/16/2023 v" wagon:roo signing low4on Here /li/ � %U�y/ Dore:h. Daisis— Fostl PNanremPDF Version: Applicant Signature Date Building Official Date CONDITIONS Adhere to approved appliances.Approved permit shall be onsite during installation.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 08/16/2023 Web Only-Mechanical Commercial Plan Review $176.01 08/16/2023 Processing/Technology $25.00 08/16/2023 Air Cond. Units 100 BTU/h $15.00 08/16/2023 Forced Air Heat>100 BTU/h $25.00 08/16/2023 Mechanical Base $25.00 Total Due: $266.01 Total Payment: $0.00 Balance Due: $266.01 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail v ,�, ��� �O ,����� 55 r' i i s r i Permit#: 5524 Permit Date: 08/07/23 Permit Type: Project Name: Coastal Community Bank- Smokey Point-HVAC Applicant Name: D.K. Systems, Inc Applicant Address: PO Box 886, PO Box 886 Applicant, City, State, Zip: Burlington Contact: Dulce Herrera Phone: 360-755-1555 Email: dulce@dksystemsinc.com Scope of Work: Replace Like for Like (1) Furnace and (1)Air Conditioner Valuation: 10000.00 Square Feet: 8856 Number of Stories: 1 Construction Type: 11113 Occupancy Group: B; Business ID Code: Permit Issued: 08/16/2023 Permit Expires: 02/03/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning COASTAL 31052800201000 16419 SMOKEY POINT COMMUNITY 611 Banking&Bank BLUR BANK Related Functions Contractors Contractor Primary Contact Phone Address Contractor Type License License# D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION COA 602 204 164 Street CONTRACTOR D.K.Systems,Inc Dulce Herrera 360-755-1555 962 S Spruce CONSTRUCTION L&I DKSYSI*982L1 Street CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. 09/11/2023 MECHANICAL 09/12/2023 10/12/2023 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 08/08/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $176.01 Review (Table 4-1) Processing/Technology $25.00 Air Cond.Unit<100 BTU/h Enter#of units $15.00 Forced Air Heat> 100 BTU/h Enter#of units $25.00 Mechanical Base Permit Fee $25.00 Total $266.01 Attached Letters Date Letter Description 08/16/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/16/2023 XBP Conf: $266.01 151775679 Outstanding Balance $0.00 Notes Date Note Created By: 10/12/2023 Received photo verifying the contractor put contact information on the furnace unit.KO Kristin Foster checked and approved. Uploaded Files Date File Name 10/16/2023 17198224-20230811 BLD5524 ApprovedPlans.pdf 08/16/2023 16538591-20230816 BLD5524 IssuedPermit.pdf