Loading...
HomeMy WebLinkAbout17501 59th Ave Ne_BLD5551_2026 Customer Name: Cement Distributors Inc Jon, Dan and Larry NQ ? l?Q_�i I"ROM Address: 17501 59th Ave NE Arlington WA 98223 HEATING & AIR Jurisdiction: City of Arlington Place home street view below: Place site plan here: J' � ice° •�� - I � _ r t c r� Submittal Variable Speed Convertible Air Handler 3 Ton TEM8AOC36V31 DB 0 0 • Do o . 0 0 D Note:The TEM8 series air handler is designed for installation in a closet,utility room,alcove,basement,crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. March 2018 TEM8A0C36-SUB-1 C-EN 40H Ingersoll Rand Outline Drawing 1.00 21,12 I.00 It.15�7.97 MINIMUM UNIT CLEARANCE TABLE SERVICE CLEARANCE IRECOMMENDCD, SIDES 2" FRONT 21" 01.13 BACK 0" B C INLET DUCT I" OUTLET DUCT N/A NOTE:THIS UNFF IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL AS 5,03 STATED ON THE UNIT RATING NAMEPLATE 2.59 i 00 1.11 � 02.00 I I 0.88 2.71 F O s.15 0 O 6.88 ¢2.00 0 Q 1.13 O A 61 IY.5P0 1.15 O � O O O H O O 6.78 UE 0 1 d,32 0 .33 .87 18.15 1.12 3,69 I.d6 2 PLCS 38 871 1.15 L E F D .87� PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEM8AOC36V31DB 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 All dimensions are in inches 2 TEM8A0C36-SUB-1 C-EN Product Specifications MODEL TEM8AOC36V31DB F.L.Amps 3.9 RATED VOLTS/PH/HZ 208-230/1/60 FILTER RATINGS(a) See O.D.Specifications Filter Furnished?M No INDOOR COIL—Type Plate Fin REFRIGERANT R-410A Rows—F.P.I. 4-14 Ref.Line Connections Brazed Face Area(sq.ft.) 4.59 Coupling or Conn.Size— 7/8 in.Gas Tube Size(in.) 3/8 Coupling or Conn.Size— 3/8 Refrigerant Control TXV in.Liq. Drain Conn.Size(in.)(b) 3/4 NPT DIMENSIONS H x W x D DUCT CONNECTIONS See Outline Drawing Crated(In.) 52-3/4 x 27-1/2 x 25-1/2 INDOOR FAN—Type Centrifugal Uncrated 51-3/8 x 23-1/2 x 21-1/8 Diameter-Width(In.) 11 X 8 WEIGHT No.Used 1 Shipping(Lbs.)/Net(Lbs.) 155/144 (a) These Air Handlers are A.H.R.I certified with various Split System Air Drive-No.Speeds Direct-16 Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance CFM vs.in.w.g. See Fan Performance Table data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) No.Motors—H.P. 1-1/2 (c) Remote filter required. Motor Speed R.RM. Variable Volts/Ph/Hz 208-230/1/60 Minimum Airflow CFM TEM8AOC36V31DB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG 675 675 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 950 900 BAYHTR1510BRK,BAYHTR151OLUG 950 900 BAYHTR1517BRK 950 900 BAYHTR351OLUG 950 900 BAYHTR3517LUG 1050 950 BAYHTR1523BRK 1500 1300 TEM8A0C36-SUB-1 C-EN 3 Heater Pressure Drop Table Number of Racks Heater Racks Airflow 1 2 3 4 Heater Model No.of Racks CFM Air Pressure Drop-Inches W.G. BAYHTRI504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTRI508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1517 3 1100 0.01 0.03 0.05 0.09 BAYHTRI522 4 1000 0.01 0.03 0.04 0.09 BAYHTRI523 4 900 0.01 0.03 0.04 0.08 BAYHTR3517 3 800 0.01 0.03 BAYHTRI525 4 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP-2 ton TEM8AOC36V31 4TWR6024H1000A 13 Degrees 4TWX6024H 1000A 4A6H6024H1000A 15 SEER HP-2 ton TEM8AOB24V21 4TWR5024G1000A 14 Degrees TEM8AOB30V31 4A6H5024G1000A 15 SEER HP-3 ton TEM8AOB30V31 4TWR5036G1000A 14 Degrees TEM8AOC36V31 4A6H5036G1000A TEM8AOC42V41 All other matches must be charged per the nameplate charging instructions 4 TEM8A0C36-SUB-1 C-EN Performance and Electrical Data 0 0 0 0 o O o 0 0 0 0 0 0 Oi O Ln 00 y 0 M Ln Ln0 OO OO MO �,.�L1 NO ^O OO �O 10 O O OO lD.ti n n O N ti n n 0 7 ti.--i M O O N N N M .� M N ti O M.--� M N M N O l0 N M N M ti M CON 0 M .-1 V y y M .--I t M Ln In .-1 M Ln M Ln M 1) LLJ 3 0 0 0 0 0 0 0 M o 0 0 0 0 M lO oo M N b N � N N 01 y In It O1 M Ln M I0 0 Ln 0 M ^I1 00 LLrI, 0 " 0 I� M Ln � n ON CD N N bo N 00 NLn MN ON Nl0 M Ln Ln Ln HM Mlfl Ln Ln O l0.--I O N y N .-1 M O N �y N y M .-i N M V In M V y Ln O T W K JO C a M O U Ln O CO N O M It OtO tO 0) -0 Ln MO 0O1 NCO 0)0 ^n NO 00 � N CD ItE M n O Ln O Ln M 00 0) M to F O r . 00 0 NO 'iN CO� ON N N MM 0 NO NMN MM Ln V -4N MM Ln Ln LnLn i a J Q LO O O M Ln .--i 0' 7 .--� N 7 7 t0 N Z M 0 co l .- Ln �N N 'DO N O ^t0 M O V O1 N M O M O 0 N M .-i.--i 00Ln p C d N � ON OLn �O nN OO N MO 0Ln NN 7•--� InN .�O 7•--� 10� 100 H W O r, O•--� 0•--� .--I•--� CO�--� 0•--� N .--I N .--i`ti �N .--I M Ln� .--I N .--I M I Ln @ L H X N +� Z W a u 0 H n M n M N Ln 10 .� 00 t0 00 � Ld C 00 MM MN lnN 00 00 N M MO .-1 O l0� „'i N M „'� a+ LL MLn OO O0 .--ice �O ON N� MM N --i N^ V Ln ID kD Ln �Ln O n ^M N U Z O OJ W N N M i N M 't '0 C t C SOW � " � " �� � � �� � � �� �� � " � � � y 3 O LL LL Lp LL O LL L0 W L0 LL N LL LD LL Lp LL Lp LL Lp LL L0 LL r0 LL Lp LL N LL Lp L ro LL O `t O �o U� v� u� U� U� U� v� U v� U� � � U� c�� v� u � U� fu Q U @ 7 w LL '0 (U N V CJ 3:(7 C C C C C C C C C C C C C C C C a) fu H z p o o O o 0 0 0 0 0 0 0 0 0 } o 0 0 = v Z �� 0) Ln o C Ln Gi u) 00� Ln CD Lr) 00� Lf) 01 o� cD Ln `3 0 3 a Qa.Lu N� MLL 7LL t-LE N � M� - 7� N� M� - V N� Ln� V �� N O � W�,W LL LL LL LE LL LL LL LL LL LL LL LL LL M LL LL_ LL 2 Q M U U U U V U U U U U U U U U V U p E Z E C O 0 Ln co NCO .~-IO N M Ln Ln �n n �M �O O MO .--I -T 0 7 E N C U n O O V O n N O \ 0 M. O � O \ � n \ \ N \ n C 0� .--i l!1.--i \N N t0.ti \N N 0 O M \N �N p ID M p O Ln 0)N 0 W O N Ln O N Ln O O i \\ \\ \ \ \\ \ \ M \ \ \ n \ � \ \ n \ M \ O \ O O N 0 0 Ln O O O OM Ln Ln O C O CD 0 M.--i 0 OM Ln N o M.--i 0 M ti 0 �0 L`'),--i O M,--i o M.--i o H V Q U W C LO.--i n n O N .--i n O t\ O 7 a,.--i .ti O O N N N �"� .--i .--� N 10 O �"� .--� V 0 LO N CON ti M ti M O N ti M ti V V ti M ti V lfl Ln 'y M Ln In lfl Z v a \ tnM nN On O M N n O M O In N.-i OD N O O O O O .--i N Ln Ln O O . M O Ln O.--i \ n \ Ln M O \ 00 \ 00 \ O \ LO \ M, \ .--i \ �--� LL ^ .--I l0.--I ^.-I O N '0.-I O N O N O O M O N 0 0 N 0 0 M O C) O^N C N M O M lf1 O f0 ad U \ \ \ N n \ V1 M O O M O O \ \ M \ O \ O \ n \ O Ln O \ O \ Q }' O O O O O .--i O O N M O N M M E C M l0 .--I M 01 .-I 7.--I O N.--I In M�..�O l/'1 N�--�n M.--I Lr) u1�--�M .--i,--�N M•y In v1�--�O LL ate+ n n O N N LO V N n N ^co `"� Ln �"� N M N ''"� O "'� In *"� Ln �""� M �"� In *"� t0 t0.--i O0 N O N M O N O N M 1 O N M V Ln M V 11'1 �O O W c 3 (j M Ln O 00 O O � N O .^-I 00 O O 7 - N N 01 O M n N n O \ 1O \ M co \ n \ LO \ co \ Ln \ O \ 01 \ 01 W 7 Ln Ln.--I n•--I O•-I �N N�.--� ON Ln0 N MunM O•-� NCON 01MM INN V N CO N 01�M `'"�- ON V 7 O 2 0- o \\ N\ M\ \\ \\ �\ u,�\ o N\ o\ �ti\ O N\ ��\ COp\ O M\ Mom\ ln�\ v LL L F OO M 0 0 M 0 N't N CC 01 N -.--i N .--i M 0 .--i CO .ti N "'i� .--i� .ti O "i.I�- �'"i 00 ra W N.--i CO.^-i N N 00.--i N N M N N M 7 N M In Ln a O CO [l N O M '~00 N N 0) 7 M n N 7 M Ln n M O O O 7 N Ln \ O N N \ 00 \ \ - \ N \ Ln \ LO \ Ln \ M \ Ln \ LO \ lO 0 M n O 00 �a,N CO.--I co M0)N LnMM .--�.N-I r"� 01HN V 00N •--�M't N^N 70 M 't MI LON� 7 rl Q O \\ \\ O\ 0\ \\ 100\ N�\ n M\ MD\ �N\ NM\ Oil\ O \ Nam\ ,--i�\ O�\ 6 n O V 7 ID V .--i N O M O,--�00 N,--�0• CO.--i i0 O.--�CO N.--�at V,--�M Ln.--�M .ti.-� T 7�..i M LO.--i.--i LO,--i Ll1 > N O O N O Ln *"� 01 n N �"� LO �"� .--� �"� CO �"� M *"� N �"� +--I N O �"� +--I *"� V �"� O 0 N J n 00.--i .-i .--i 00 N N .--i N M N M Ln C Q U Z ^ N 0 n M O 0 N 00 n O O O if to a M N n M \ M \ n O O \ LO \ .--i \ O \ � \ N .--I \ N \ O \ N \ M \ Q F �..� On O� ^�.--i M�.ti Oi ^N.--i OM N 't NN NN.-1 ��N ti M ,--i�V OOr,N �p NM CO V 0 V VL CO \\ \\ OD\ Mti\ \\ lnti\ ON\ t0�\ N ti\ MM\ �\ 00\ tON\ .--ice\ N O\ .- O\ 0) y W 0 Ln O M N O,y O ,--i.--�M CON O,.i N N�..�O M.--i O O,�M N�..�O l0 �0.--i O +"� Ln V �O n .--i 7 M Ln CO ""� 0 ""� 7 � �"� N �"� lD ""� M ti .-� N N ti Ln •--I In •--I In •--I r-I Ln .--I r-i n .--I'ti M Cr n 00 O .--i .� COO .--i .--i N .-1 .--i N M .--i N M V v Ca L � CO 3Q� y y o U .d LL LL LO LL t0 LL t0 LL Lp LL N LL O LL t0 LL LO LL LO LL LO LL r0 LL MLL N LL LO LL i0 LL O > a o_ a a� a U L» U O O O O LO� O O 0 ll1 O O O OpZ oO o� o� o o � o Epp a � i rn L O0 ui 0 M 0 LL N N MLn LL �p LuNLL LL LL LL LL LL LL M LL LL LL m W U Q Ln U U U U V V V U U V U CO� CaJ ) '3 u a) c Y to L O W to to } 0 J 0 E J U) C N C O N E c +� 3 p a z o c o 0 J Ln M Ln LL afu N C O�t N M } (n i--i TEM8AOC36-SUB-1 C-EN 5 Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Note:Heater size needs to be set in Configuration Menu. Table 1. Electrical Data TEMSAOC36V31DB,TEMSAOC42V41DB HEATER DATA 240 Volt 208 Volt No.of Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW I BTUH Circuit Ampacity Protection No Heater 3.9* 5 15 3.9* 5 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 22 25 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 39 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 BAYHTR1510LUG BAYHTR1517BRK 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 Circuit 1(a) 2/1 BAYHTR1517BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 BAYHTR1523BRK 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 Circuit 1(a) 2/1 BAYHTR1523BRK 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 Circuit 2 BAYHTR3510LUG 1/3 9.60 32800 23.1 33 35 7.20 24600 20.0 29 30 BAYHTR3517LUG 1/3 14.40 149100� 34.6 48 50 10.80 36900 30.0 42 45 *=MotorAmps (a) MCA and MOP for circuit I contains the motor amps 6 TEM8AOC36-SU BI C-EN Features and Benefits • Communicating or 24 V control • Variable Speed ECM Motor • Painted metal cabinet with captured foil face • Low Voltage Pigtail Connections insulation • Draw Through Design • 2%or less air leakage • Horizontal Drain Pan • R-4.2 Insulating Value • Single Color • Multi-Position UP/Down Flow,Horizontal Left/Right . Fused 24V Power • ALL Aluminum Coil with Enhanced Patented Coil . 3 year warranty Fin • Electric Heaters with polarized plug connections • 10-year warranty registered (sold as accessory) • Optional extended warranty available • R-410A Thermal Expansion Valve TEWAOC36-SUB-1 C-EN 7 4j:PIngersoll Rand. Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car@, Ingersoll Rand@, Thermo King@ and Traneo—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. JB Ingersoll Rand T THERMO KING 92 TRANE' ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TEM8A0C36-SUB-1C-EN 19mar2018 Supersedes TEm8AX36-SUB-16-EN (August 2017) ©2017 Ingersoll Rand i COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 This application is for new, addition,altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition ❑ Alteration ❑✓ Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 17501 59th Ave NE Project Valuation: 21986.00 Lot#: Parcel ID No.: Preferred Contact: 0 Owner 71 Contractor Project Description: Like in kind AH and HP replacement Owner Name: Cement Distributors Inc-Jon Walden Office No.: 360-403-7335 Email Address: Jon@cementdistributors.com Cell No.: Mailing Address: 17501 59th Ave NE City: State: —Zip:Arlington WA 98223 Contractor Name: Nordstrom Heating and Air Office No.: 360-386-9819 Email Address: office@nordstromheating.com Cell No.: MailingAddress: 1059 State Ave Suite G City: Marysville state: WA zip: 98270 L&I Contractor License Number: Nordsha7721_2 6/26/ 55 Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS, Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 NY Not Applicable Proposed Piping Material: 0 CSST 13 Brass 0 Other O Black Steel 0 Galvanized Steel Proposed Piping Size: 0 1/2 ❑ s/8" ❑ 3/4" O 1" O 11/2" 0 2" Inlet Pressure: Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES (per unit T e of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $ 75.00 = $ Air Cond.Unit<_100Btu h x $ 15.00 = $ Air Cond. Unit>100Btu h x $ 5.00 = $ Air Cond.Unit>SOOBtu/hp x $ 50.00 = $ Air Handling-units 1 x $ 15.00 = $15.00 Base Mechanical Fee $ 25.00 Boiler<100Btu h>3h $ 25.00 x $ 15.00 = $ Boiler>1 million Btu h<50h x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30h x $ 25.00 = $ Commercial Hoods-Type I x $ 25.00 = $ Commercial Hoods -Type II x $ 25.00 = $ Diffusers x $ 15.00 = $ Dryer Ductingx $ 15.00 = $ Ductwork(drawings required) x $ 25.00 = $ Evaporative Coolers x $ 15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $ 25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC :5100 Btu h x $ 15.00 = $ Gas Fired AC>100 Btu h x $ 25.00 = $ Gas Fired AC > 500 Btu h x $ 50.00 = $ Gas Pi in 5 5 units x $ 15.00 = $ Gas Piping> 5 units (plus <5 units x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit 1 x $ 25.00 = $25.00 Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by $ 15.00 $ mechanical code,not otherwise specified x = Pkg. Units_<100btu x $ 25.00 = $ Pkg. Units>100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit 5100Btu h x $ 15.00 = $ -Refrigeration Unit>100Btu/h x $ 25.00 4- x Refrigeration Unit>500Btu h x $ 50.00 Re-inspection fee all x $ 75.00 Unit Heaters < 100 Btu h x $ 15.00 Unit Heaters>100 Btu h $ 25.00 = VAV Boxes (Variable Air Volume,part of air $ 10.00 $ conditioning system) x = Wall Heaters- Gas Fired x $ 25.00 = $ Water Heater-Gas Fired x $ 25.00 = $ Permit Fee $ o Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated I hereby certify that I am the[]owner, ❑Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington.A final inspection and approval shall be obtained when complete. Jessica Schuerman 8/15/23 Signature Print Name Date REv2.2020 SAVE PRINT Page 3 of 3 A KJOR www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:201922493 Date:08-07-2023 Model Status:Active AHRI Type: HRCU-A-CB(Split System: Heat Pump with Remote Outdoor Unit-Air-Source) Series:Platinum 19 Outdoor Unit Brand Name:AMERICAN STANDARD Outdoor Unit Model Number (Condenser or Single Package):4A6L9036A1 Indoor Unit Model Number(Evaporator and/or Air Handler):TEM8AOC36V31+TDR The manufacturer of this AMERICAN STANDARD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240-2017 with Addendum 1,Performance Rating of Unitary Air-Conditioning& Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:36000 SEER: 17.00 EER(A2)-Single or High Stage(95F): 12.00 Heating Capacity(H 12)-Single or High Stage(47F):33600 HSPF(Region IV): 11.00 Rated as follows in accordance with the latest edition of AHRI 2101240—2023,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(AFull)—Single or High Stage(95F),btuh:36400 SEER2: 17.50 EER2(A Full)—Single or High Stage(95F): 11.50 Heating Capacity(H1Fuii)—Single or High Stage(47F),btuh:33600 HSPF2(Region IV):9.00 t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. The Department of Energy has published updated energy efficiency metrics for central air conditioners and heat pumps.This publication reflects both the 1987 metric(SEER)and the 2023 metric(SEER2).Efficiency requirements are published at 10 C.F.R.430.32(c).Please refer to www.AHRInet.org for more information about updated energy efficiency metrics. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2023Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133359246685730213 S HEATING & AIR CONDITIONING Submittal Side Discharge Variable Speed HP For coastal applications where units are installed within one(1)mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. Epoxy Coated Model 4A61-9036A1000A 4A61-9036A1COTA 1 Note: "Graphics in this document are for representation only. Actual model may differ in appearance." March 2020 4A6L9036A-SUB-1 C-EN Akwaw S wdard HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A6L9036A1XXXA (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(e) 208-230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 26.9 (b) Rated in accordance with AHRI standard 275. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATION@-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—Variable this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208-230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 12.4/48.9 (e) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. M Standard Air—Dry Coil—Outdoor START COMPONENTS(e) NO (e) This value approximate.For more precise value see unit nameplate. INSULATION/SOUND BLANKET YES (h) Reference the outdoor unit ship-with literature for refrigerant piping SUMP HEAT YES length and lift guidelines.Reference the refrigerant piping software pub#32-3312-xx or refrigerant piping application guide SS- OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes DIA.(IN.)—NO.USED 27.5—1 latest revision). TYPE DRIVE—NO.SPEEDS DIRECT—VARIABLE Center Mass Dimensions CFM @ 0.0IN.W.G.M 2400 0 0 0 0 0 0 NO.MOTORS—HP 1-1/2 MOTOR SPEED R.P.M. 200-1050 VOLTS/PH/HZ 325-385 VDC/3/60 F.L.AMPS 2.3 �o OUTDOOR COIL—TYPE PLATE FIN ROWS—F.P.I. 2-16 FACE AREA(SQ.FT.) 12.88 TUBE SIZE(IN.) 5/16 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 8 LBS,0 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 0 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS o SUBCOOLING COOLING MODE 10°F DIMENSIONS H X W X D 40.25' CRATED(IN.) 42 x 56 x 24 CenterofMass CenterofMass „BA .A� UNCRATED(IN.) 36-3/4 X 47 X 17-1/2 W2 wt WEIGHT SHIPPING(LBS.) 250 NET(LBS.) 226 Model 2 Ton 3 Ton 4/5 Ton Total Weight 206 228 247 W1(LB) 135.63 143.03 150.35 Dim"A" 13.75 15.00 15.75 W2(LB) 70.37 84.97 96.65 Dim"B" 26.50 25.25 24.50 2 4A61_9036A-SUB-1 C-EN Aftwe-4WS7�WOdAdo HEATING & AIR CONDITIONING Outline Drawing SERVICE PANEL J- LSD rry 0 L C K IOU ID LINE SERVICE VALVE, Tc I.D.TENALE BRAZE CORRECTION WIT'Ile•SAE FLARE PRESSURE TAP EI TTI NGS. CCESS PAXfL +B F Hy GAS LINE 114 TURN BALL SERVICE VALVE D J —� SHOULD XE Ai LEAST IBt.1 I6 IXCXESI FROM WALL AXD I.D.FENALE BflAZEO CONNECTION WI iH Ild'SAE G GA (2 FEETI A.SURROUNDING SNAUDDERY ON ALL SIDES. iLAflE PRESSURE TAP FI ii IN6. FIGURE 2 SERVICE PANEL - ACCESS14-9132 PAXfL �a > u Y $I-3132 HIGH VOLTAGE 2-I/B I I A 4Tie LOW VOLTAGE ELECTRICAL AXD REPO IGEflAXi CONPONE AT <LEAflANfES PEI PREVAILING CODES. IOU ID LINE SERVICE VALVf.�E.I.D.FENALE BRAZED COXN Eti ION WI iN Ild'SAE FLARE PRESSURE TAP TIiiIN6. H o F i GA_S LINE SERVICE VALVf. J --L D I.O.EENALE BRAZED CONNECTION WIT"N"SAE FLARE G PRESSURE TAP flit lNG. FIGURE 1 Model Base A B C D E F G H J K 4A6L9036A 4.3 934 1194 445 16 10 (54/ 159 (3 101 --31/ 187 495 (36-3/4) (47) (17-1/2) (3/4) (3/8) 16) (6-1/4) 32) (7-11/32) (19-1/2) 4A6 L9036A-S U BI C-E N 3 �c icati, �S'7 iw HEATING & AIR CONDITIONING Sound Pressure Level Outdoor Unit Reflective Surface 3'ft (Back wall) 5'ft Table 1. 3.0 Ton Heating Sound Pressure Level dB(A)per ARI 275(Max Heating) 3' S' 7' #Reflective Surfaces from Property Line from Property Line from Property Line 0 46 41 1 490) 44 2 52 47 44 M Lab tested as per the illustration shown above Table 2. 3.0 Ton Cooling Sound Pressure Level dB(A)per ARI 275(Max Cooling) 3' S' 7' #Reflective Surfaces from Property Line from Property Line from Property Line 0 45 1 48(a) 43 2 51 46 43 (a) Lab tested as per the illustration shown above Notes: 4A6L9036A1 Sound Characteristics • Measuring place:Hemi-Anechoic chamber _ _Coaine —Heating • Sound pressure level will vary depending on a range of factors such as the construction 0 of the particular room where the equipment is installed. -1 i • Operation sound level may differ depending 2 / on operation and ambient conditions. r -3 — W m v / -S 0 20 40 60 80 1W 1 %Demand 4 4A6L9036A-SUB-1 C-E N �cati, �S'7 iw HEATING & AIR CONDITIONING Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with Inverter driven scroll compressor with 50 to 100% the system charge required for the outdoor condensing output capacity. Noise enclosure minimizes sound unit,ten (10)feet of tested connecting line,and the levels and built in compressor protection will reduce smallest rated indoor evaporative coil match.This unit operating speed and current draw to maintain is designed to operate at outdoor ambient operation while protecting the compressor. temperatures from 55'F to 120'F in cooling. From — Condenser Coil 10'F to 66°F in heating.Only AHRI approved indoor matches are approved for use with these models. The copper tube,aluminum fin outdoor coil provides low airflow resistance and efficient heat transfer.The This outdoor unit contains the AccuLinkT"^ digital coil is protected by a wire guard. communication with 2 wire connection to outdoor and Plug-n-Play set up. Low Ambient Cooling Casing As manufactured,this system has built in freeze protection that will allow cooling operation down to 45' Unit is painted with a glossy corrosion resistant finish F but will reduce capacity or shut down completely to on all panels. prevent operation under adverse conditions. Refrigerant Controls Comfort Control Refrigeration system controls include condenser fan, The 1050/950/850 Control is required and provides high and low pressure switches.A factory supplied, Plug-n-Play setup and 3 wire connection. field installed filter drier is standard. 4A6 L9036A-SUB-1 C-E N 5 Aw ew Si�uidsrd HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. Unitary Small HP C o L US AHRI Standard 210/240 1 LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4A6L9036A-SUB-IC-EN 19Mar2020 Supersedes 4A6L9036A-SUB-1 B-EN (July 2018) ©2020 American Standard Heating and Air Conditioning A;wsrie-uw SqAm , HEATING & AIR CONDITIONING Submittal Side Discharge Variable Speed HP For coastal applications where units are installed within one(1)mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. Epoxy Coated Model 4A6L9036A1000A 4A6L9036A1COTA O r CITY OF ARLINGTON BUILDING DEPARTMENT Note:"Graphics in this document are for representation only. APPROVED Actual model may differ in appearance." DATE-9A J-Z��BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Received AUG 15 2023 March 2020 4A6L9036A-SUB-1 C-EN �Q�;k 4AWc " S*Rda d HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT(e)(b) 4A6L9036A1XXXA 0) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ W 208-230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH,CIR.AMPACITY 26.9 (b) Rated in accordance with AHRI standard 275. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers orfuses. COMPRESSOR DURATION@-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—Variable this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208-230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 12.4/48.9 (e) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. START COMPONENTS(e) NO (f) Standard Air—Dry Coil—Outdoor W This value approximate.For more precise value see unit nameplate. INSULATION/SOUND BLANKET YES (h) Reference the Outdoor unit ship-with literature for refrigerant piping SUMP HEAT YES length and lift guidelines.Reference the refrigerant piping software pub#32-3312-xx or refrigerant piping application guide SS- OUTDOOR FAN PROPELLER APGO06-xx for long line sets or specialty applications(xx denotes DIA.(IN.)—NO.USED 27 5—1 latest revision). 'TYPE DRIVE—NO.SPEEDS DIRECT—VARIABLE CFM @ 0.0IN.W.G.(f) 2400 Center Mass Dimensions NO.MOTORS—HP 1-1/2 MOTOR SPEED R.P.M. 200-1050 VOLTS/PH/HZ 325-385 VDC/3/60 F.L.AMPS • / \ e 2.3 OUTDOOR COIL—TYPE PLATE FIN ROWS—F.P.I. 2—16 4 FACE AREA(SQ.FT.) 12.88 TUBE SIZE(IN.) 5/16 I REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 8 LBS,0 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 -- CHARGING SPECIFICATIONS a SUBCOOLING COOLING MODE 10°F DIMENSIONS H X W X D nozs CRATED(IN.) 42 x 56 x 24 centm dMan centerof Mass B. .A. UNCRATED(IN.) 36-3/4 X 47 X 17-1/2 Wz W, WEIGHT SHIPPING(LBS.) 250 NET(LBS.) 226 Model 2 Ton 3 Ton 4/5 Ton Total Weight 206 228 247 W1(LB) 135.63 143.03 150.35 Dim"A" 13.75 15.00 15.75 W2.(LB) 70.37 84.97 96.65 Dim"B" 26.50 25.25 24.50 2 4A6L9036A-SUB-1 C-EN HEATING & AIR CONDITIONING Outline Drawing MAN.<I r— O L C K -p4 Lix[9[AV VALVE. To S,r[vu[eAAAE WAIuiW l 1 s.[ qAA[vA6s.rAP[x AW miuG4 L Kass INNIL m 8 + F N 4A LINE it BALL SERVICE VALVE.T- 'I xWLO 0[ l f isu w�^iA[xix9 reDx TAIL Ax i4 5 f[xxl[D BPNIO CDxxA[CEOK'.;p fif XAF 6P9{1 rE[Li CADx A W DiAG u0 EAA L>A ALLDP iO[5 AA[ A[95DPF A fi L G�1 FIGURE 2 NpM.AANA AN -- A[<[09 P.NA AN \ ANmi�DxP vO�iA4[ 0 AAD I A 1 ,Y iv PK{ \ EL[fAiCAL AND A[rAl4IN111 P[AAVAE 1no6 CW f em,�K uena - iN PINE Au f���K N`` T i W I Nh.fI INK. le{NCAiO�iHIN�iw4wW G .IIe0111 IM f N FIGG URE I Model Base A B C D E F G H J K 101 4A6L9036A 4.3 934 1194 445 16 10 (2 1/ —1/ (3 31/ (7 18/ 495 (36-3/4) (47) (17-1/2) (3/4) (3/8) 16) (61/4) 32) —1132) (19-1/2) 4A6L9036A-SUB-1 C-EN 3 4tic ?4w S-lavdard. HEATING & AIR CONDITIONING Sound Pressure Level Outdoor Unit Reflective Surface �-- 3'ft (Back wall) 5'ft Table 1. 3.0 Ton Heating Sound Pressure Level dB(A)per ARI 275(Max Heating) #Reflective Surfaces 3 5' 7' from Property Line from Property Line from Property Line 0 46 41 1 49(a) 44 2 52 47 44 (a) Lab tested as per the illustration shown above Table 2. 3.0 Ton Cooling Sound Pressure Level dB(A)per ARI 275(Max Cooling) #Reflective Surfaces 3 5 7 from Property Line from Property Line from Property Line 0 45 1 48(a) 43 2 51 46 43 cal Lab tested as per the illustration shown above Notes: • Measuring place:Hemi-Anechoic chamber 4A61_9()36A1 Sound Characteristics • Sound pressure level will vary depending on —Cooling —Heating a range of factors such as the construction 0 of the particular room where the equipment is installed. -1 i • Operation sound level may differ depending i on operation and ambient conditions. -2 b i t 3 u J* m v -4 -5 0 20 40 60 r,. 100 %Demand 4 4A6L9036A-SUB-1 C-EN AAW?AW S-1zwda,t-d.. HEATING & AIR CONDITIONING Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with Inverter driven scroll compressor with 50 to 100% the system charge required for the outdoor condensing output capacity. Noise enclosure minimizes sound unit,ten(10)feet of tested connecting line,and the levels and built in compressor protection will reduce smallest rated indoor evaporative coil match.This unit operating speed and current draw to maintain is designed to operate at outdoor ambient operation while protecting the compressor. temperatures from 55°F to 120°F in cooling. From — Condenser Coil 10'F to 66'F in heating.Only AHRI approved indoor The copper tube,aluminum fin outdoor coil provides matches are approved for use with these models. low airflow resistance and efficient heat transfer.The This outdoor unit contains the Accul-inkT" digital coil is protected by a wire guard. communication with 2 wire connection to outdoor and Plug-n-Play setup. Low Ambient Cooling Casing As manufactured,this system has built in freeze protection that will allow cooling operation down to 45° Unit is painted with a glossy corrosion resistant finish F but will reduce capacity or shut down completely to on all panels. prevent operation under adverse conditions. Refrigerant Controls Comfort Control Refrigeration system controls include condenser fan, The 1050/950/850 Control is required and provides high and low pressure switches.A factory supplied, Plug-n-Play setup and 3 wire connection. field installed filter drier is standard. 4A6L9036A-SUB-1 C-E N 5 r¢kuinw Sifpffdard !ATING i Al CGNDI'I ONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. Unitary S-11 HP U` US AHRI Standard 210/240 LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 4A6L9036A-SUB-1 C-EN 19 Mar 2020 Supersedes 4A61-9036A-SUB-1 B-EN (July 2016) ©2020 American Standard Heating and Air Conditioning Submittal Variable Speed Convertible Air Handler 3 Ton TEM8AOC36V31 DB e o O 'N2 Note_The TEMB series air handler is designed for installation in a closet,utility room,alcove,basement crawlspace or attic.These versatile units are applicable to air conditioning and heat pump applications.Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. March 2018 TEM8AOC36-SUB-1 C-EN 41 Ingersoll Rand. Outline Drawing CJ •' 12 I! 21 I 1 91 100 NININI N IINIT CLEARANCE TAKE 1 SERVICE CLEARANCE IPECONNENDEDI SIDES 2' F tt• 0'13 DtICR 0• ts C IXLET DUCT I WhiT DKI N2A NOTE:THIS UNIT 15 APPROVED FOR INSTALLATION !R7 CLEARANCE5TO COMBUSTIBLE MATERIAL AS J„ STATED ON THE UNIT RATING NAMEPLATE �t9J •2.11 r OJ.N 2 17 2 12— �ZL:] 6 p1 1f L]A 1..01 x 1 is —T O � H • o A,le O I I.1J 61 le 1! 1,12 e6! 116 PLCf 2.I! E F D Ri PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEMSAOC36V31DB 1 51.27 23.50 1 21.50 21.7S 7.01 9.66 24.59 TXV 718 All dimensions are Irl inches 2 TE M WC36-SUB-1 C-E N Product Specifications MODEL TEM8AOC36V31DB F.L.Amps 3.9 RATED VOLTS/PH/HZ 208-230/1/60 FILTER RATINGS(a) See O.D.Specifications Filter Furnished?W No INDOOR COIL—Type Plate Fin REFRIGERANT R-410A Rows—F.P.I. 4-14 Ref.Line Connections Brazed Face Area(sq.ft.) 4.59 Coupling or Conn.Size— 7/8 in.Gas Tube Size(in.) 3/8 Coupling or Conn.Size— 3/8 Refrigerant Control TXV in.Liq. Drain Conn.Size(in.)(b) 3/4 NPT DIMENSIONS H x W x D DUCT CONNECTIONS See Outline Drawing Crated(In.) 52-3/4 x 27-1/2 x 25-1/2 INDOOR FAN—Type Centrifugal Uncrated 51-3/8 x 23-1/2 x 21-1/8 Diameter-Width(In.) 11 X 8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 155/144 No.Used 1 (a) These Air Handlers are A.H.R.I certified with various Split System Air Drive-No.Speeds Direct-16 Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance CFM vs.in.w.g. See Fan Performance Table data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) No.Motors—H.P. 1-1/2 a) Remote filter required. Motor Speed R.P.M. Variable Volts/Ph/Hz 208-230/1/60 Minimum Airflow CFM TEMBAOC36V31DB Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRK,BAYHTR1504LUG 675 675 BAYHTR1505BRK,BAYHTR1505LUG BAYHTR1508BRK,BAYHTR1508LUG 950 900 BAYHTR1510BRK,BAYHTR1510LUG 950 900 BAYHTR1517BRK 950 900 BAYHTR351OLUG 950 900 BAYHTR3517LUG 1050 950 BAYHTR1523BRK 1500 1300 TEM8A0C36-S1UB-1 C-EN 3 Heater Pressure Drop Table Number of Racks Heater Racks Airflow CFM 1 1 2 1 3 4 Heater Model No.of Racks Air Pressure Drop-Inches W.G. BAYHTR1504 1 18UO 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1517 3 1100 0.01 0.03 0.05 0.09 BAYHTR1522 4 1000 0.01 0.03 0.04 0.09 BAYHTR1523 4 900 0.01 0.03 0.04 0.08 BAYHTR3517 3 800 0.01 0.03 BAYHTR1525 4 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP-2 ton TEM8AOC36V31 4TWR6024HI000A 13 Degrees 4TWX6024H 1000A 4A6H6024H1000A 15 SEER HP-2 ton TEM8AOB24V21 4TWR5024G1000A 14 Degrees TEM8A01330V31 4A6H5024G1000A 15 SEER HP-3 ton TEM8AOB3OV31 4TWR5036G1000A 14 Degrees TEM8AOC36V31 4A6H5036G1000A TEM8AOC42V41 All other matches must be charged perthe nameplate charging instructions 4 TE M 8AOC36-SUB-1 C-E N Performance and Electrical Data O Ln O O p O O l f 7 V 1 O O O O p O O O O p O p O p O O O p O O O O LT LO.-I r,r-, .--IN Mn 0n V �.-I M0 MN NN r, lTN 10O n� ON mN O O N 00 N M y M co N M .~-I I. V C)M 'N-I .Mi L1l M �••I Ln Ln Ln Ll 3 LL' o 0 0 0 0 0 o M o 0 0 0 0 O' N M 1D '-I M N 0 .-� '""I ^0, ,.�Ln 0, !`"1 Ln M ID O Ln O I,n n M 0 Ln O 0 O n M n N 00N p 0 'tN n N p0 N Ln MN p n ryLD M� Ln� '-I M M� Ln Ln`� O Ln O 10_ 0o N N -M 0 N N ry r, V ,y N �••I rn V 'y In M 0 T W +O W LY C CL .--i Ln M O N Ol n N O, V O Q U �� O0 N O OM-1 V �l0 110 Cr) 00 Ln N 00 Ln 0, V 0 �0 n 000 0,0 M'^a Ln� X O M lb t\ O V n 0 N n Ln O OD n 0, .--I LD fn nLn QO n.-1 0o'-i N N 00.1 O N ry Irl O�N N M-1 M ti V 'y N �..L M .�In ,..i In OL W a n U7 r0 a a rn O O_ f+l N0 W N �Ln V O I,N 00 N� ^0 M� V N Nti TN �00 O V'� i0 V 'D0 O F L O n 0.-i .-I .-I 00.-1 '•i ,Ny N My N CD'y ti N It M Ln V ,y N '+M '+V .+ La F N OJ Z w Ln F ,y In M ry� MM 0 nN 0)GoV O N M �0 V 'i LO OD Ln ID 0 M j0 U- O VI In ON Op 'n V nN lnN C � lDM N ti M^ .--�L4 OLn 00 •�� N^ '�M N U — p L�Ln 0 0 O ti .r.ti 0 0 O'.I N.--i N O.-i .ti V N 0 M N M ^V CO Z .--I M -� O C 0 O L U 3 v W w to Ln rn In rn Ln Iyn In Iyn N Ln vl ul Ln o U �_ Q J y ay.+ N y L 1.� �..i f y y y y f�i i+ �r �0LL LL LL LL W W W W LL 10 W N W N lL IO lL M lL IO LL IO W IO 3 u� uZ. u� u� u� u� u� u� U� v� u� u� u� u� u� u� Y c V ` ¢ OJ aJ U. LU 3 U C C C C C C C C C C C C C C C C — M T H Z p Z o 0 0 0 0 0 0 0 0 0 0 0 o t y o o ar > Z oy oy o o+ oL o\ o2 o+ oL o- oL p+ o� o o� HJ al\ Ln\ o\ Ln m Ln o\ Ln\ C, In\ O\ Ln\ D,\ o\ C) In\ 3 FLQ�� N M� V V N LL M LL LL V �� N M LL �� V LLL N L LL M L L V LL V W '0 E y =¢ U u U U V U U U U U U U U U U u 0 O nm 0 �o �V NM OMLn vNi^ r. �M 0D � Ln 0� `i \ N \ N o E ai mN t0 O V O t\ N 0 \ ,O ^'i O 01 \ O \ O 0 .-I Q j L O V.--I1'r, Ln.-I ^N O N lO' ^N N p 0 M N N p M M p 0 In N p V p Ln �p Ifl\ \ \ \ ,..� \ t0 M \\ CO N N = O L \\ \N \ \ \\ \ \ M,y\ \ \\ I�,..i\ of Iyl\ O I�,y\ O I�.l\ O,M\ F Q U 0 oLn o0 00 0Ln Lno 00 CD0o M'.,o CD oo I`'l.�o M,.,0 o rr, 0 M.,o M,yp W C 0.--i n t\ ~O N n 0 n 00 O,'-i •� Go N N N •--� .--I •-1 N ID M '+ ,..L '+ N ~ ry V O l0 N ON tiM �yM OON IM ,..I V �..IM V Ill N �M In In Ln u - Z \ lfl M n N m n M N n M 0 In '-I CO Ln O 0 00 O O �. .-I N lfl In 0 M 0 Ln '+ \ r \ lfl O \ O0 \ 0 \ O \ LO \ O N O.--I 00 N p N N p CT f,•l W N p�N C) M O.Ln p 0 N 0 N M O Q Ln p M Ln M 19 U \\ \\ \ \ q \ .--I O\ �\ O\ Mp\ CON\ OI.n\ n p\ 0 ry\ O MOM\ E LLpMl0M NOl �rl n O, i Ln 'i Q, LnN�..�1\ M --I Ln Ln M .--I ti r, M.-1 Ln Ln 0 rl N cc n n 00 N to N 00 LnN M N - LD `� Ln •-I Ln •� M ti Ln `� 0 0 N N M N M V OD N M V L+1 M V Ln to O W c - a (,j^ M Ln ip CO ^� O 0 .�-I� r'.�-i N D, ti 00 't 00 O V ti N N io 0 O V M 0ti ON r,V 00 \N lD \MM 00 \0 \M 0 \ry0 \nN \nOMD \N� 0 W O 0 Ln.--i ^'a \ .�N n.--I \N Ln O N Irl M \,-� N N N 0l O M it l0 V N 0_ Ol N_ In O (31 OJ LY Q p O 0 N O M lD lD 0 Q\ '�O N.-I n M'N-I O M 0, N.�00 M.M-I 00 Ln n O M ti 00 M'i rs N'-I V0 t0 {L U O M 00 n MO O n V N to N '� n `� Ln O O '-i 0 .-I n .ti O `� 0 '-i n - ,.-i .•L n.--I 00.ti M N -N 00.-i �y N N M '-i N N M V N M Ln Ln N Ln M M W O Q d N 0,M 0 N N O V M N N V M Ln n 0 0 E m o O V N Ln \ O n N \ 0 \ V \ �"� \ n \ Ln \ ,o \ Ln \ M I.,,, M to \ ,0 U n O, CD.-1 .ti M N 0.--I In'-I O N V M N.--I N M N '-1 ID V N Ln N V M Ln i�In 7 M \\ \\ \\ V 0\ \\ LO V\ N�\ I�OM.I\ MQ\ �N\ N�\ o,�\ 0�\ N�\ .--I M\Epp\ l7 Q O ^0 V V i0 V "'�00 N 0 M O 00 N fn,y 0 O.-+O N..-i O V,y M Ln,M .ti V V.y M LD.--�.1 'O�..�In (n N Ol 0 N ~O Ln '� Ol n N •� 0 •� •� •� 0 •� Ln `� N `� rI '� N '� O '� '� '� V '� O N Ln n 00'-i .--I ..-I O0•--I '+ N N '+ N M V N M V Ln ti V Z n N N 00 I\ n V O O, 0 Ln Ln O LY M N n M \ M \ n 0,0 O \ .-a \ 0 V \ N V.--I \ N \ O \ N \ M M N p Q W OD r, T� ^CO.-i Mom- 0) ^�'� m�N V NN ryN.--I Ln.N-iN \M 'a�V Lp^N ,D OIM 0�V V p V M V \\ \\ O p\ M�..�\ \\ Ln \ O ry\ LD V\ N ti\ M M\ \ O l0\ tO N\ r-1 V\ N 0\ '-I O\ N N WO Ln 0 M N .-a O ,ti M 0 L.y O�.ti N .-I 0 M'-i O O,y M "'i LVn '+ .-�,-I Ln +V-I LIVI 'i^ '+'�In LT C M Ln o0 O V n N ID "'' M '"i '+ 11 n 0 0 .-L '-i 0 0 .-L .-I N N M ti N M V W LL 0 n v n n m LEr v Ln n v U i O W �i f �N y �i f i �i LL (u zL Fes' C:) _ W LO LL IO LL M W M LL Ip LL LO U- !0 LL LO LL i0 W 10 W j0 W Lp W M LL M LL IO LL f0 ,-I Ln LL�o u� u� u� u� u� u� u� u� u� u� u� u� u� u v� u� ai t a v M u ai OU U C C C C C C C C C C C C C C C C C z o z o o O o 0 0 0 0 0 0 0 0 o t o 0 0 E .0 C, C L o L o L o 2 o+� o 2 o 0 o 2 o+� o L o+� o L o y o+� J Ln\ O\ In O,\ ln\ O\ Vl\ 01\ Ln\ O\ In\ IT\ O\ O\ lll\ C O W N� M� �� �£ �� N� n� �g �� Ng n� O W W W W W W LL W W W W W W W M W W W — ~ U Q(n U U U U U U U U U U U U U U U U C O C al .3 u In O C 7 J w v E O�tn c o rn � L3 E O a Z o O R o n v O J O N M f`'1 V t fn O C O TEM8AOC36-SUB-lC-EN • • 5 Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Note_Heater size needs to be set in Configuration Menu. Table 1. Electrical Data TEMBAOC36V31DB,TEMSAOC42V41DB HEATER DATA No.of 240 Volt 208 Volt Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 3.9* 5 15 3.9* 5 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 22 25 BAYHTR1504LUG BAYHTR1505BRK BAYHTR1505LUG 1/1 4.80 16400 20.0 30 30 3.60 12300 17.3 27 30 I BAYHTRI508BRK BAYHTR1508LUG 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 39 40 UG BAYHTR1510BRK 1/1 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 BAYHTR1510LUG BAYHit1(-) BRK 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 Circuit 1(a1 2/1 BAcuit2 17BRK 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 Circuit 2 BAYH BRK Circuit 1 1(a) 2/1 9.60 32800 40.0 55 60 7.20 24600 34.6 48 50 BA 23BRK Circuitcuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 2 BAYHTR351OLUG 1/3 9.60 32800 23.1 33 35 7.20 24600 20.0 29 30 BAYHTR3517LUG 1/3 14.40 49100 1 34.6 48 50 10.80 36900 30.0 42 45 *=Motor Amps (al MCA and MOP for circuit 1 contains the motor amps 6 TEM8A0C36-SUB-1 C-EN Features and Benefits • Communicating or 24 V control • Variable Speed ECM Motor • Painted metal cabinet with captured foil face • Low Voltage Pigtail Connections insulation • Draw Through Design • 2%or less air leakage • Horizontal Drain Pan • R-4.2 Insulating Value • Single Color • Multi-Position UP/Down Flow,Horizontal Left/Right . Fused 24V Power • ALL Aluminum Coil with Enhanced Patented Coil . 3 year warranty Fin • Electric Heaters with polarized plug connections • 10-year warranty registered (sold as accessory) • Optional extended warranty available • R-410A Thermal Expansion Valve TE WAOC36-SUB-1 C-E N 7 j�Ingersoll Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car@, Ingersoll Rand®, Thermo KingG and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. ® tiI`ilingersoll Rand THERMO KING 0 fRAA�' ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TEM8A0C36-SUB-1C-EN 18Mar2018 Supersedes TEM8AOC36-SUB-IB-EN (August2017) ©2017Ingersoll Rand cr) N O i N s� i i t o -- K � t .a N O- _ C 00 'Cat let WIV N a) a ~` O L Li L E ca N Z (D a`) o E cn _r_ o CD 0 U U Q d i p CITY O ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17501 59TH AVE NE Permit#:5551 Parcel#:31052200401700 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:replace Airhandler and HP Valuation:21986.00 OWNER APPLICANT CONTRACTOR CEMENT DISTRIBUTORS Nordstrom Heating and Air NORDSTROM HEATING&AIR INC 17501 59TH AVENUE NE 1059 State Ave Suite G 1059 State Ave. Ste.G ARLINGTON,WA 98223 Marysville,WA 98270 MARYSVILLE,WA 98270 360-386-9819 425-335-4029 LIC:601 764 617 EXP:06/30/2024 LIC:NORDSHA772L2 EXP:06/26/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST.TYPE: IA DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I OARCI 10. SALES TAX NOTICE.-Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 09/01/2023 +� Appl' ant Signature Date Building Official Date CONDITIONS ADHERE TO THE INSTALLATION OF THE APPROVED EQUIPMENT.PROVIDE 3"CONCRETE PAD WITH SEISMIC BRACING ATTACHED.PROVIDE ELECTRICAL DISCONNECT.LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPES IS PROHIBITED.APPROVED JOB COPY SHALL BE ONISTE FOR INSPECTIONS.CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description 09/01/2023 Web Only-Mechanical Commercial Plan Review Fee Amount 09/01/2023 Processing/Teclinology $339.86 09/01/2023 Air Handling Unit $25 0f] 09/01/2023 Heat Pump-Condensing Unit $15.00 $15.00 Total Due: $394.86 Total Payment: $0.00 Balance Due: $394.86 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Qn- � CITY OF ARLINGTON 18264 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17501 59TH AVE NE Permit#:5551 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052200401700 DATE OF ISSUANCE. Scope of Work:replace Airhandler and HP Valuation:21986.00 OWNER APPLICANT CONTRACTOR CEMENT DISTRIBUTORS Nordstrom Heating and Air NORDSTROM HEATING&AIR INC 17501 59TH AVENUE NE 1059 State Ave Suite G 1059 State Ave. Ste.G ARLINGTON,WA 98223 Marysville,WA 98270 MARYSVILLE,WA 98270 360-386-9819 425-335-4029 LIC:601 764 617 EXP:06/30/2024 LIC:NORDSHA772L2 EXP:06/26/2025 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: 1 CONST.TYPE: IA DWELLING UNITS: OCC GROUP: B;Business BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 09/01/2023 Applicant Signature Date Building Official Date CONDITIONS ADHERE TO THE INSTALLATION OF THE APPROVED EQUIPMENT.PROVIDE 3"CONCRETE PAD WITH SEISMIC BRACING ATTACHED.PROVIDE ELECTRICAL DISCONNECT.LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPES IS PROHIBITED.APPROVED JOB COPY SHALL BE ONISTE FOR INSPECTIONS. CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/01/2023 Web Only-Mechanical Commercial Plan Review $339.86 09/01/2023 Processing/Technology $25 0n 09/01/2023 Air Handling Unit $15.00 09/01/2023 Heat Pump-Condensing Unit $15.00 Total Due: $394.86 Total Payment: $0.00 Balance Due: $394.86 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail Permit#: 5551 Permit Date: 08/15/23 Permit Type: COMMERCIAL MECHANICAL Project Name: Cement Distributors Applicant Name: Nordstrom Heating and Air Applicant Address: 1059 State Ave Suite G Applicant, City, State, Zip: Marysville,WA 98270 Contact: Jessica Schuerman Phone: 360-386-9819 Email: office@nordstromheating.com Scope of Work: replace Airhandler and HP Valuation: 21986.00 Square Feet: 2492 Number of Stories: 1 Construction Type: IA Occupancy Group: B; Business ID Code: Permit Issued: 09/01/2023 Permit Expires: 02/28/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200401700 17501 59TH AVE NE CEMENT 300 INDUSTRIAL/ DISTRIBUTORS MANUFACTURING Contractors Contractor Primary Contact Phone Address Contractor Type License License# NORDSTROM 1059 State Ave. CONSTRUCTION HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR COA 601764617 NORDSTROM 1059 State Ave. CONSTRUCTION Labor&NORDSHA772L2 HEATING&AIR INC 425-335-4029 Ste.G CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C 14. 09/06/2023 MECHANICAL Anytime works 09/07/2023 09/07/2023 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 08/15/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Enter 1 if permit is for commercial Web Only-Mechanical Commercial Plan mechanical $339.86 Review (Table 4-1) Processing/Technology $25.00 Air Handling Unit $15.00 Heat Pump-Condensing Unit Enter#of units $15.00 Credit Card Service $11.85 Total $406.71 Attached Letters Date Letter Description 09/01/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/01/2023 XBP Conf: $394.86 152995067 09/01/2023 152995067 AmeresiaLawlis $11.85 Outstanding Balance $0.00 Notes Date Note Created By: 09/01/2023 Emailed the permit for signature. Kristin Foster Uploaded Files Date File Name 09/01/2023 16730225-20230901 BLD5551 IssuedPermit.pdf 08/15/2023 16521914-20230815 BLD5551 App.pdf 08/15/2023 16521915-20230815 BLD5551 HPSpecs.pdf 08/15/2023 16521916-20230815 BLD5551 AerialView.Pdf 08/15/2023 16521917-20230815 BLD5551 AHSpecs.pdf