Loading...
HomeMy WebLinkAbout17833 59th Ave Ne Ste C_BLD5605_2026 COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223 •Phone(360)403-3551 This application is for new,addition,altered or replaced mechanical installation and new or altered gas piping and must be accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition © Alteration © Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 17833 59th Ave suite D Arlington WA 98223 project Valuation: $90,000.00 building# Lot#:10 Parcel ID No.: Preferred Contact: 0 Owner 0 Contractor Project Description: remove and replace two exhaust fan and collection filter for existing fiberglass larnination processes. using existing make up air unit Owner Name: Fluid Motion LLC Office No.: Email Address: dennispearson@rangertugs.com Cell No.: 425-212-8136 Mailing Address: 17939 59th Ave NE City: Arlington State: WA Zip:98223 Contractor Name: Superior Systems Office No.: 360-466-1234 Email Address: trev@supersystemsinc.net Cell No.: 360-708-0669 Mailing Address: 13576 Bayview-Edison rd City: Mt Vernon State: Zip: WA 98273 L&I Contractor License Number: Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips)are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 0 Not Applicable 0 CSST 0 Brass 0 Other Proposed Piping Material: O Black Steel D Galvanized Steel Proposed Piping Size: 0 1/2" 0 s/s" 0 3/4" 1" 0 11/2" 0 2" Inlet Pressure: Pressure Drop: Specific Gravity: REV03.2022 Page 1 of 3 MECHANICAL PERMIT FEES fper unit Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees x $75.00 = $ Air Cond.Unit<-100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h x $25.00 = $ Air Cond.Unit>50OBtu/hp x $50.00 = $ Air Handling Units x $ 15.00 = $ Base Mechanical Fee $25.00 $25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $25.00 = $ Boiler>1.5 million Btu/h<50hp x $50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $25.00 = $ Commercial Hoods-Type I x $25.00 = $ Commercial Hoods-Type II x $50.00 - $ Diffusers x $ 15.00 = $ Dryer Ducting x $15.00 = $ Ductwork(drawings required) x $25.00 = $ Evaporative Coolers x $15.00 = $ Exhaust Ventilation Fans x $ 15.00 = $ Fireplace/Insert/Stove x $15.00 = $ Forced Air Heat<-100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu h x $25.00 = $ Gas Clothes Dryer x $ 15.00 = $ Gas Fired AC<-100 Btu h x $ 15.00 = $ Gas Fired AC>100 Btu h x $25.00 = $ Gas Fired AC> 500 Btu h x $50.00 = $ Gas Pi in -< 5 units x $ 15.00 = $ Gas Piping> 5 units (plus<5 units x $2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 = $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 = $ mechanical code,not otherwise specified Pkg.Units<-100btu x $ 25.00 - $ Pkg.Units>100btu x $ 50.00 = $ Range/Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit 5100Btu h x $ 15.00 = $ Refrigeration Unit>100Btu h x $25.00 = $ Refrigeration Unit>500Btu h x $50.00 = $ Re-inspection fee all x $75.00 = $ Unit Heaters s 100 Btu h x $ 15.00 = $ Unit Heaters>100 Btu h x $25.00 = $ VAV Boxes (Variable Air Volume,part of air x $10.00 = $ conditioning system) Wall Heaters-Gas Fired x $25.00 = $ Water Heater-Gas Fired x $25.00 = $ Permit Fee $ Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2020 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated I hereby certify that I am the❑Owner,❑Applicant [ Contractor,and authorized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation he State of Washin on,and the City of Arlington.A final inspection and approval shall be obtained when complete. Dennis Pearson 9/18/20 Signature Print Name Date REV2.2020 SAVE PRINT Page 3 of 3 711 de obi a a m m N O N w N O r n 7AVA �:. 4 - j�l u -- T A XI + f K OO U i� j _ IX f { iid//• ` J � t 1��� pTS PAINT BOOTH DUCTWORK SPIRAL DUCT ire root ti entiiato-provides protection against it Sold by the foot,spiral ducts are available rain, snow and backdrafts for the exhaust in 2-to 8-foot lengths.All sizes are system, paint booth and operator.All sizes are constructed from galvanized steel and constructed from galvanized steel.Requires require connector rings on each end some assembly and may require connector rings (sold separately). (sold separately). , i DU-SPP-10 10" DU-ARV-10 10" DU-SPP-12 12" DU-ARV-12 12" DU-SPP-18 18" DU-ARV-18 18" DU-SPP-24 24" DU-ARV-24 24` DU-SPP-30 30" TM W DU-SPP-34 34- DU-ARV-34 34" DU-SPP-36 36" DU-ARV-36 36" DU-SPP-40 40" DU-ARV-40 40" DU-SPP-42 42" DU-ARV-42 42" DU-SPP-48 48- DU-ARV-48 48" EXHAUST STACK KITS EXHAUST DUCT Exhaust stack kits include three 3-foot An exhaust duct comes with a straight, plain exhaust duct sections,one 3-foot 3-foot-tong section,with one end universal stack with access door and one corrugated for easy installation.All sizes roof ventilator. are constructed from galvanized steel and require some assembly. M6W oil DU-STK-10 10` DU-STK-12 12" DU-PLP-10 3 10" DU-STK-18 18" DU-PLP-12-3 12" DU-STK-24 24" DU-PLP-18-3 18" DU-STK-30 30" DU-PLP-24-3 24" DU-STK-34 34" DU-PLP-30-3 30" DU-STK-36 36" DU-PLP-34-3 34' DU-STK-40 40" DU-PLP-36-3 36" DU-STK-42 42" DU-PLP-40 3 40" DU-PLP-42-3 42" DU-PLP-48-3 48" CONNECTOR RINGS Connector rings are used for connecting an exhaust fan to other exhaust system stack components.One connector ring is t supplied with fan assemblies. 409-110 10" 409.112 12" 409-118 18" 409 124 24" 409-130 30" 409-134 34" 409-136 36" 409-140 40" 409-142 42" 409-148 48" 23 alobalfinistina.com I)Al'I Off.Clean:fir.30 in blade. I ubea:xial Fan-7F84217F842-... https:i;'%�-%%-%%.grainger.cornrproduct/DAYTON-Tubeaxial-Fan-Clean... GRADIM. IM Tubeaxial Fans / DAYTON Tubeaxial Fan:Clean Air,30 in... DAYTON Tubeaxial Fan: Web Price Clean Air, 30 in Blade, $3,198.14jeach 14,040 cfm @ 0.000 in SP, This item requires special shipping, 208-230/460V AC, 3 Phase additional charges may apply. oty Item 7F842 Mfr. Model 7F842 1Add to Cart I • Ship Pickup Expected to arrive Mon. Sep 25 Compare Ship tc 98233 1 Change Product Details Catalog Page 2940 Shipping Weight 267.6lbs Ship Availability Terms DAYTON For Air Type Clean Air add to List Drive Type Belt Drive Q Alternate Products fj Includes Motor& Drive Package Yes Assembly Unassembled A Blade Diameter 30 in Airflow @ 0.000 in SP 14,040 cfm DAYTON Tubeaxial Fan: Clean Air,30 in Blade, 16,495 cfm C Airflow @ 0.125 in SP 13,630 cfm 0.000 in SP, 208-230;'460V AC, 3 Phase Airflow @ 0.250 in SP 13,180 cfm Item 7F843 Airflow @ 0.500 in SP 12,220 cfm Compare Maximum Noise Level @ 5 Feet 52 sones Web Price B Nameplate Voltage 208-230i460V AC $3,240.88 /each aty Phase 3 1 Add to Cart Frequency 60 Hz Current 8.7 to 7.8/3.9 A Motor Enclosure Totally Enclosed Fan Cooled Motor Horsepower 3 hp ® Chat with an Agent Brake Horsepower 2-91/100 hp I of 4 9 21'2023.8:57 A111 I),-%y type(-Ica rse in Blade. I ubeaxial Fan-7F8.t2 7F842-... https: -.titi%�s grainger.comiproduct/DAYTON-Tubexxial-Fan-Clewi... motorMotor Speed 1,740 RPM Maximum Fan Speed 1,320 RPM DAYTON Tubeaxial Fan: Flammable Vapor, 30 in Number of Speeds 1 Blade, 14,040 cfm C 0.000 in Motor Hazardous Location Rating Not Rated SP,230/460V AC, 3 Phase Item 7F846 Housing Material Steel Compare Housing Finish Baked Enamel Web Price Blade Material Aluminum S3,833.16 /each Qty Maximum Inlet Air Temperature 200 `F 1 Add to Cart Maximum Ambient Temperature 104 `F Mounting Orientation Horizontal;Vertical Number of Blades 6 Bearing Type Ball Bearing Bolt Circle Diameter 32-1/4 in Propeller Shaft Diameter 1-1/4 in Body Diameter 30-5/8 in Overall Diameter 33-5/8 in Overall Height 46-5/8 in Overall Length 24 in Standards AMCA Resistance Properties Rust Resistant Spark Resistant Construction Type B Manufacturer Part Number 71`842 Compatible Flange Grainger Part Number 3C440 Replacement Fan Blade Part Number 3C418 Includes Belt Guard Features Streamlined Belt Tunnel UNSPSC 40101604 Country of Origin Varies (subject to change) Product Description Clean air fans with drive are primarily used to supply fresh air and exhaust odorous, hot,or stale air.These fans come with a drive package that includes a motor, sheaves, belts, and bushings. Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive exhaust fans ® Chat with an Agent t 3 9/2 12023.8:57 AM Product Specification ULTRA MEDIA SYNTHETIC FILTER MEDIA 1.0 Scope This specification covers synthetic media that is a component of paint booth systems. Media can be used in paint overspray, adhesive overspray, oil mist or sanding dust collection. 2.0 Construction 2.1 Media The media shall be gradient density, 100% polyester fiber. The media shall be white on the air entering side and have a dense needled purple layer on the air leaving side. No halogen, ammonium sulfate or ammonium phosphate shall be used in this media. 2.2 Product Availability The media shall be available in precut pads, blankets and bulk rolls. 3.0 Performance The filters shall meet the following minimum performance requirements for pant removal, based on using high solids bake enamel and ASHRAE Standard 52.2- 2012. Performance shall be representative of all sizes offered. ASHRAE 52.2-2012 Nominal Size 24 x 24 Rated Face Velocity (FPM) 295 Initial Resistance 0.15" W.G. Final Resistance 1.00" W.G. MERV 8 Revised 04/18/201-8 Product Specification Paint Removal and Capacity 40 CFR Part 63 National Emission Standard Nominal Size 20 x 20 Rated Face Velocity (FPM} 150 Initial Resistance 0.05" W.G. Final Resistance 0.50" W.G. Average Removal Efficiency 99.48% Penetration 7.8 grams Paint Holding Capacity 1 3.2 pounds Revised 04/28/2018 2 PAINT ARRESTANCE FILTER TEST REPORT Spray Removal Efficiency&Paint Holding Capacity BASED ON 40 CFR PART 63 NATIONAL EMNIMION STANDARD __— Tested for: ATI 0.5 lean Filter Filter Mfr.: ATI Filter Name/Model: Ultra Pad n 0.4 Report#.tTest# R 675 T 775 a0.3 Report Date:. April 1,2005 a 0-2 _. ....._- r Test Information 0 loo 150 200 25G 30O FILTER DESCRIPTION(20"x 20"pad): Air Velocity(FPM) --- _ _ ---- Picrple and white highloft poly pad _ ---- -._:_ _ . _. _._. PAINT DESCRIPTION: 1.2 Pressure Dro High Solids baking enamel(S:YJ. l Permaclad 240Q red) 1.0 — — --- — PAINT SPRAY METHOD: =o.g Conventional Air Gun at 40 PSI !SPRAY FEED RATE: a 0,6 i 136 gr.:min. 130 cc./rnin. ^0.4 1AiR VELOCITY: 150 FPM 0,2 _ — j 0.0 f 0 500 1000 1500 2000 2500 Test Results Wt.Paint Fed(g.) INITIAL PRESSURE DROP of Clean Test Filter 15 Penetration, 0.05 in.Water FINAL PRESSURE DROP of Loaded Test Filter 12 -- 0.50 in.water WEIGHT GAIN of FILTER and test frame trogh 1508 grams PAINT HOLDING CAPACITY of TEST FILTER 1454 grams 3.2 tbs. 3 m PAINT RUN-OFF 0 54 grams 0 500 1000 1500 2000 2500 WEIGHT GAIN-FINAL FILTER Wt.Paint Fed(g.) 7.8 grams= PENETRATION _. ---- _.___ _._ AVERAGE REMOVAL EFFICIENCY of TEST FILTER %Removal Efficiency 99.48°o 100 01 c 95 s i 4o 0 500 1000 1500 2000 1-500 Test Engineer: Todd Krujer Wt.Paint Fed(g.) Supervising Engineer: K.C.Kwok,Ph.D. -_----.------ __�_. ----------- CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE-9��ZJ BY J!�Q 7 N NO CHANGES AUTHORIZED UNLESS APPROVED BY THE 'fk BUILDING INSPECTOR AL T AYJ Roo ul j . .. =F PAINT BOOTH DUCTWORK SPIRAL DUCT The roof ventilator provides protection against Sold by the foot,spiral ducts are available rain,snow and backdrafts for the exhaust in 2-to 8-foot lengths.All sizes are system, paint booth and open wor.Ail sizes are constructed from galvanized steel and constructed from galvanized steel.Requires require connector rings on each end some assembly and may require connector rings (sold separately). (sold separately). DU-SPP-10 10" DU-ARV-10 10" DU-SPP-12 12" DU-ARV-12 12" DU-SPP-18 18" DU-ARV-18 18" DU-SPP-24 24' DU-ARV-24 24 OU-SPP-30 30" aiiaw DU•SPP-34 34" DU-ARV-34 34" DU-SPP-36 36" DU-ARV-36 36" DU-SPP-40 40' DU-ARV-40 40" DU-SPP-42 42" DU-ARV-42 42" DU-SPP-48 48" — DU-ARV-48 48" EXHAUST STACK KIPS EXHAUST DUCT Exhaust stack kits include three 3-foot An exhaust duct comes with a straight, plain exhaust duct sections,one 3-foot 3-foot4ong section,with one end universal stack with access door and one corrugated for easy installation.All sizes roof ventilator. are constructed from galvanized steel and require some assembly. DU-STK-10 10" DU-STK-12 12" DU-PLP-10.3 10" DU-STK-18 18" DU-PLP-12-3 12- DU-STK-24 24' DU-PLP-18-3 18" DU-STK-30 30" DU-PLP-24-3 24" DU-STK-34 34" DU-PLP-30-3 30' DU-STK-36 36" DU-PLP-34-3 34" DU-STK-40 40" DU-PLP-36-3 36" DU-STK-42 42" DU•PLf-40.3 40' DU-PLP-42-3 42" DU-PLPA8-3 48• - CONNECTOR RINGS Connector rings are used for connecting an exhaust fan to other exhaust system stack components.One connector ring is r' ' supplied with fan assemblies- I 409-110 10" 409.112 12" 409-118 18" 409-124 24" 409-130 30' 409-134 34" t it At 409-136 36� ,Ilk 409 140 40" f 409-142 42" 409-148 48" • . . 11 � u DAYTON,Clean Air.30 in Blade,Tubeaxial Fan-71784217F842-_._ https:/hi»u:grainger.comfprndLkc DAYTON-Tubeaxial-Fan-Clean... try Tubeaxial Fans / DAYTON Tubeaxial Fan:Clean Air,30 in-- DAYTON Tubeaxial Fan: Web Price Clean Air, 30 in Blade, $3,198.14/each 14,040 cfm @ 0.000 in SP, This item requires special shipping, 208-230/460V AC, 3 Phase additional charges may apply_ city— Item 7FB42 Mfr.Model 7F842 1 , Ship Pickup Expected to arrive Mon.Sep 25. Compare Ship to 98233 1 Change Product Details Catalog Page 2940 Shipping Weight 267.6 lbs Ship Availability Terms Brand DAYTON For Air Type Glean Air Add to List Drive Type Belt Drive Includes Motor&©rive Package Yes 0 Alternate Products Assembly Unassembled Blade Diameter 30 in Airflow @ 0.000 in SP 14,040 cfm DAYTON Tubeaxial Fan_Clean Air,30 in Blade, 16,495 cfm C Airflow @ 0.125 in SP 13,630 cfm 0.000 in SP,208-230/460V Airflow @ 0.250 in SP 13,180 cfm AC,3 PhaseItem 7l 843 Airflow @ 0.500 in SP 1 Z220 cfm Compare Maximum Noise Level @ 5 Feet 52 sones Web Price Nameplate Voltage 208-230i460V AC $3,240.88/each City Phase 3 1 Add to Cart Frequency 60 Hz Current 8.7 to 7.8/3.9 A Motor Enclosure Totally Enclosed Fan Cooled Motor Horsepower 3 hp ®Brake Horsepower 2-91/100 hp Chat with an Agent I of 4 9/1-1,1023,8:57 AM MO to( IypBI mSSA0 in Blade, fui�iai Fan-7F&12j7F&47-_.. https `r�ititizv.grainger.corn product/DAYTO\-Tubeaeial-Fan-Cleut_._ Motor Speed 1,740 RPM Maximum Fan Speed 1,320 RPM DAYTON Tubeaxial Fan: Flammable Vapor,30 in Number of Speeds 1 Blade, 14,040 cfm @ 0.000 in SP,230/460V AC,3 Phase Motor Hazardous Location Rating Not Rated Item 7F846 Housing Material Steel Compare Housing Finish Baked Enamel Web Price Blade Material Aluminum $3,833.16/each Maximum Inlet Air Temperature 200'F 1 Add to Cart Maximum Ambient Temperature 104'F Mounting Orientation Horizontal;Vertical Number of Blades 6 Bearing Type Bali Bearing Bolt Circle Diameter 32-1/4 in Propeller Shaft Diameter 1-1/4 in Body Diameter 30-518 in Overall Diameter 33-5/8 in Overall Height 46-5/8 in Overall Length 24 in Standards AMCA Resistance Properties Rust Resistant Spark Resistant Construction Type B Manufacturer Part Number 7FS42 Compatible Flange Grainger Part Number 3C440 Replacement Fan Blade Part Number 3C418 Includes Belt Guard Features Streamlined Belt Tunnel UNSPSC 40101604 Country of Origin Varies(subject to change) Product Description Clean air fans with drive are primarily used to supply fresh air and exhaust odorous, hot,ar state air.These fans come with a drive package that includes a motor, sheaves,belts,and bushings_Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive exhaust fans. ® Ghat with an Agent 2 oF4 91'21F1023.8.57 AM i 41 Kp Permit#: 5605 Permit Date: 09/21/23 Permit Type: COMMERCIAL MECHANICAL Project Name: Fluid Motion Applicant Name: Superior Systems Applicant Address: 13576 Bayview-Edison Rd Applicant, City, Mount Vernon, WA State, Zip: Contact: Dennis Pearson Phone: 425-212-8136 Email: dennispearson@rangetugs.com Scope of Work: Remove and replace two exhaust fans and collection filters for existing fiberglass lamination processes using existing make-up air unit Valuation: 90.00 Square Feel. Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: COMMERCIAL MECHANICAL Status: IN PROCESS Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 17833 59TH AVE NE STE ADVANCED 300 INDUSTRIAL/ 31052200403900 C MANUFACTURING MANUFACTURING PARK Contractors Contractor Primary Contact Phone Address Contractor Type License License# 13576 Bayview MECHANICAL L&I SUPERS*196 5 Superior Systems Mack Wolfe 360 466-1234 Edison Rd CONTRACTOR Q Plan Reviews Date Review Type Description Assigned To Review Status 09/22/2023 COMMERCIAL BUILDING In Review MECHANICAL Fees Fee Description Notes Amount Processing/Technology $25.00 Exhaust/VentsNent Fans $30.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $22.10 Total $102.10 Uploaded Files Date File Name 09/22/2023 16969638-20230920 BLD5605 ExhaustFanlnfb.p- 09/22/2023 16968639-20230920 BLD5605 Specs.pdf 09/22/2023 16968640-20230920 BLD5605 App Plancpdf COMMERCIAL MECHANICAL APPLICATION Community&Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 This application is for new,addition,altered or replaced mechanical installation and new or altered gas piping and mustbe accompanied by ELECTRONIC CONSTRUCTION DRAWINGS and CUT SHEETS and/or information outlined in the MECHANICAL SUBMITTAL REQUIREMENTS,if applicable. Type of Permit: ❑ New Installation ❑ Addition 0 Alteration © Replaced ❑ Gas Piping Type I and Type H Hood Systems required submittal of the Commercial Mechanical Addenda Property Address: 17833 59th Ave suite D Arlington WA 98223 Project Valuation: $90,000.00 building#Lot#:10 Parcel ID No.: Preferred Contact: 0 Owner ❑Contractor remove and replace two exhaust fan and collection filter for existing faberglass Project Description: l afio ro ake up air unit Owner Name: Fluid Motion LLC Office No.: Email Address: dennispearson@rangertugs.com Cell No.: 425-212-8136 Mailing Address: City: State: Zip: 17939 59th Ave NE Arlington WA 98223 Contractor Name: Superior Systems Office No.: 360-466-1234 trev@supersystemsinc.net Cell No.: 360-708-0669 Email Address: 13576 Bayview-Edison rd Mt Vernon WA 98273 Mailing Address: City: State: Zip: L&I Contractor License Number: Expiration Date: New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips)are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 41S • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 3 O Not Applicable ❑CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ %ll ❑ 5/s' ❑3/4' ❑1" ❑ 11/z" ❑ 2" Inlet Pressure: Pressure Drop: Specific Gravity: Page 1 of 3 REV03.2022 MECHANICAL PERMIT FEES(per unit Type of Fixture _ No.of Units Cost er Unit Subtotal Additional Plan Review fees x $75.00 I = $ Air Cond.Unit s100Btu x $15.00 = $ Air Cond.Unit>100Btu h x $25.00 = $ Air Cond.Unit>50OBtu/hp x $50.00 = $ Air Handling Units x $15.00 = $ Base Mechanical Fee $25.00 $25.00 Boiler<100Btu h>3h x $15.00 = $ _ Boiler>1 million Btu/h<50hp x $25.00 $ Boiler>1.5 million Btu/h<50hp x $50.00 = $ Boiler>100Btu 3-15h x $15.00 = $ Boiler>500Btu h 15-30hp x $25.00 = $ Commercial Hoods-Type I x $25.00 = $ Commercial Hoods-Type II x $50.00 = $ Diffusers x $15.00 = $ Dryer Ducting x $15.00 = $ Ductwork (drawings required) x $25.00 = $ Evaporative Coolers x $15.00 = $ Exhaust Ventilation Fans x $15.00 = $ Fireplace/Insert/Stove x $15.00 = $ Forced Air Heat<_100 Btu h x $15.00 = $ Forced Air Heat>100 Btu h x $25.00 = $ Gas Clothes Dryer x $15.00 = $ Gas Fired AC:5100 Btu h x $15.00 = $ Gas Fired AC>100 Btu/h x $25.00 = $ Gas Fired AC>500 Btu h x $50.00 = $ Gas Pi in _<5 units x $15.00 = $ Gas Piping>5 units (plus<5 units x $2.00 = $ Heat Exchangers x $15.00 = $ Heat Pump-Condensing Unit x $25.00 = $ Hot Water Heat Coils x $15.00 = $ Miscellaneous Appliance-regulated by x $15.00 _ $ mechanical code,not otherwise specified Pkg.Units<_100btu x $25.00 = $ Pkg.Units>100btu x $50.00 = $ Ran a Cookto -Gas Fired x $15.00 = $ Refrigeration Unit 5100Btu h x $15.00 = $ Refrigeration Unit>100Btu h x $25.00 = $ Refrigeration Unit>500Btu h x $50.00 = $ Re-ins ecrion fee all x $75.00 = $ Unit Heaters:5 100 Btu h x $15.00 = $ Unit Heaters>100 Btu h x $25.00 = $ VAV Boxes r'ariable Air Volume,part of air $10,nn _ $ Y x _ conditioning system) Wall Heaters-Gas Fired x_ $25.00 = $ Water Heater-Gas Fired x $25.00 = $ Permit Fee $ Table 4-8;Plan Review Fee $ Processing/Technology Fee $25.00 Total $ REV2.2020 Page 2 of3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s)from meter to all appliances NOTE:Any interior pressure regulators must be indicated I hereby certify that l am the❑Owner,[ Applicants ❑Contractor,and authoirized to sign this application and that the above information is correct and construction on,and the occupancy and the use of the above-desclribed property will be in accordance with the laws,rules and regulation - lie State of Washin on,and the City of Arlington.A final inspection and approval shall be obtained when complete. Dennis Pearson 9/18/20 - Signature Print Name Date SAVE PRINT Page 3of3 REV2.2020 I Ca f L�- 0 7 CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED C3 DATE�1-7 BY Q NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR L� I CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATEJ,��i2-7 BY J�Q N NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR 17> W- Axi Kl�C)r (' L'IZ Ix / + 1 = r _ 7 �Jj 8 Uit. 3 PAINT BOOTH DUCTWORK SPIRAL DUCT The roof ventilator provides protection against Sold by the foot,spiral ducts are available rain,snow and backdrafts for the exhaust in 2-to 8-foot lengths.All sizes are system,paint booth and operator.All sizes are constructed from galvanized steel and constructed from galvanized steel.Requires require connector rings on each end some assembly and may require connector rings (sold separately). (sold separately). 41 DU-SPP-10 10" DU-ARV-10 10" DU-SPP-12 12" DU-ARV-12 12" DU-SPP-18 18' DU-ARV-18 18" DU-SPP-24 24' DU•ARV-24 24" DU-SPP-30 30' VINFUi-k-30 301 DU-SPP-34 34- DU-ARV-34 34' DU-SPP-36 36' DU-ARV-36 36" DU-SPP-40 40' DU-ARV40 40" DU-SPP-42 42' DU-ARV-42 42' DU-SPP•48 48" DU-ARV-48 48" EXHAUST STACK KITS EXHAUST DUCT Exhaust stack kits include three 3-foot An exhaust duct comes with a straight, plain exhaust duct sections,one 3-foot 3-foot-long section,with one end universal stack with access door and one corrugated for easy installation.All sizes roof ventilator. are constructed from galvanized steel and require some assembly. DU-STK-10 10" IWI _ DU-STK-12 12" DU-PLP-10-3 10' DU-STK-18 18" DU-PLP-12-3 12' DU-STK-24 24' DU-PLP-18-3 18' DU-STK-30 30" DU-PLP-24-3 24' OU-STK-34 34" DU-PLP-30-3 30" DU-STK-36 36" DU-PLP-34-3 34' DU-STK-40 40" DU-PLP-36-3 36" DU-STK-42 42" DU-PLP-40.3 40' DU-PLP-42-3 42" DU-PLPA8-3 48" CONNECTOR RINGS Connector rings are used for connecting an exhaust fan to other exhaust system stack components-One connector ring is supplied with fan assemblies. 409-110 10" 409.112 12" 409-118 18" -- 409.124 24' 409-130 30" 409-134 34" 409-136 36' 409-140 40" 409-142 42' 409-148 48' DAYTON.Clean Air,30 in Blade,Tubeaxial Fan- 217F842-__. https:/,lei»zr•.grainger.com!prodi `aYTON-Tubeaxial-Fan-Clean... GRAENM, itrr Tubeaxial Fans { DAYTON Tubeaxial Fan.Clean Air,30 in— DAYTON Tubeaxial Fan-, web Price Clean Air, 30 in Blade, $3,1 98.14/each 14,040 cfm @ 0.000 in SP, This item requires special shipping, 208-230/460V AC, 3 Phase additional charges may apply_ Item 7F842 Mfr.Model 7F842 I� Add to Cart Ship Pickup Expected to arrive Mon.Sep 25. Compare Ship to 98233 1 Change Product Details Catalog Page 2940 Shipping Weight 267.6 Ibs Ship Availability Terms Brand DAYTON For Air Type Clean Air Add to List Drive Type Belt Drive Alternate Products 0 Includes Motor&Drive Package Yes Assembly Unassembled Blade Diameter 30 in Airflow @ 0.000 in SP 14,040 cfm DAYTON Tubeaxial Fan_Clean Air,30 in Slade, 16,495 cfm Airflow @ 0.125 in SP 13,630 cfm 0.000 in SR 208-230/460V AC,3 Phase Airflow @ 0.250 in SP 13,180 cfm Item 7F843 Airflow @ 0.500 in SP 12,220 cfm Compare Maximum Noise Level @ 5 Feet 52 sones Web Price 0 (V i3mepla le VVILdVoltageLUO-LJV/YV $3,240.88/each Vv ML /�� `+y Phase 3 1 Add to Can Frequency 60 Hz Current 8.7 to 7.8/3.9 A Motor Enclosure Totally Enclosed Fan Cooled Motor Horsepower 3 hp Chat with an Agent Brake Horsepower 2-91/100 hp 1 44 9fZ l 2023,8:57 AM bea M()�ottI 1 ls.gainger.com� cDAYTOTuxaE-Eon-Cleul.-- 0iBlade, uheaaial F 7F84217F842 https_`N y32 haS2 Motor Speed 1,740 RPM Maximum Fan Speed 1,320 RPM DAYTON Tubeaxial Fan: Flammable Vapor,30 in Number of Speeds 1 Blade,14,040 cfm @ 0.000 in SP,230/460V AC,3 Phase Motor Hazardous Location Rating Not Rated Item 7FB46 Housing Material Steel Compare Housing Finish Baked Enamel Web Price Blade Material Aluminum $3,833.16/each Maximum Inlet Air Temperature 200'F 1 Add to Cart Maximum Ambient Temperature 104°F Mounting Orientation Horizontal;Vertical Number of Blades 6 Bearing Type Ball Bearing Bolt Circle Diameter 32-1/4 in Propeller Shaft Diameter 1-1/4 in Body Diameter 30-5/8 in Overall Diameter 33-5/8 in Overall Height 46-5/8 in Overall Length 24 in Standards AMCA Resistance Properties Rust Resistant Spark Resistant Construction Type B Manufacturer Part Number 7F842 Compatible Flange Grainger Part Number 3C440 Replacement Fan Blade Part Number 3C418 Includes Belt Guard Features Streamlined Belt Tunnel UNSPSC 40101604 Country of Origin Varies(subject to change) Product Description Clean air fans with drive are primarily used to supply fresh air and exhaust odorous, hot,or stale air.These fans coarse with a drive package that includes a motor, sheaves,belt%and bushings_Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive exhaust fans. � Chat with an Agent of 4 91212,2023,&-57 AM Product Specification ULTRA MEDIA SYNTHETIC FILTER MEDIA 1.0 Scope This specification covers synthetic media that is a component of paint booth systems. Media can be used in paint overspray, adhesive overspray, oil mist or sanding dust collection. 2.0 Construction 2.1 Media The media shall be gradient density, 100% polyester fiber. The media shall be white on the air entering side and have a dense needled purple layer on the air leaving side. No halogen, ammonium sulfate or ammonium phosphate shall be used in this media. 2.2 Product Availabift The media shall be available in precut pads, blankets and bulk rolls. 3.0 Performance The filters shall meet the following minimum performance requirements for pant removal, based on using high solids bake enamel and ASHRAE Standard 52.2- 2012. Performance shall be representative of all sizes offered. ASHRAE 52.2-2012 Nominal Size 24 x 24 Rated Face Velocity FPM 295 Initial Resistance 1.01 W.G. 1.00 Final Resistance "W.G. MERV 8 Revised 04/18/2018 i 1 Product Specification Paint Removal and Capacity 40 CFR Part 63 National Emission Standard Nominal Size 20 x 20 Rated Face Velocity FP 150 Initial Resistance 0.05"W.G. Final Resistance 0.50"W.G. Average Removal Efficiency 99.48% Penetration 7.8 grams Paint Holding Capacity 3.2 pounds Revised o4/i8l2m8 2 PAINT ARRESTA1 CE FILTER TEST REPORT Spray Removal Efficiency&Paint Holding Capacity BASED ON 40 CFR PART 63 NATIONAL.EMMISSION STANDARD Tested for: ATI 0-5 lean Filte Filter Wt.: ATI Filter Name/Model: Ultra Pad 0.4 Report*.,Test# R 675 T 77S ^0.3 Report Date: Apn71,2005 0_2 - --- -- ____ . _...—_-•- Test Information 0.0 0 So 100 ISO 200 250 300 FILTER DESCRIPTION(20"x 20"pad): Air Velocity(FPM) Purple and white highlofr poly pad --- -- - -- PAINT DESCRIPTION: 1.2 Pressure Dro Nigh Solids baking enamel(S.W.rl Permaclad 2400,red) �1.0 PAINT SPRAY METHOD: =0.8 Conventional Air Gun at 40 PSI 20.6 ISPP,AY FEED RATE: q i 136 gr./min- 130 cc.1min. 2 0.4 ----- AIR VELOCITY: 02 - 150 FPM 0.0 0 500 1000 1500 2000 2500 Test Results Wt.Paint Fed('g.) INITIAL PRESSURE DROP of Clean Test Filter 15 enetratio 0.05 in.water FINAL PRESSURE DROP of Loaded Test Filter 12 - - 0.50 in.water 9 -- --_--_ WEIGHT GAIN of FILTER and test frame trogh i 1508 grams 6 - - PAINT HOLDING CAPACITY of TEST FILTER — 1454 grams = 32 lbs. !PAINT RUN-OFF 0 - 54 grams 0 Soo 1000 1500 2000 2500 WE!GHT GAIN-FINAL FILTER Wt_Paint Fed(g.) 7.8 grams= PENETRATION -— -- -- --- -- - .AVERAGE REMOVAL EFFICIENCY of TEST FILTER %Removal Efficiency 99.48% 100 i U 94 90 0 500 1000 1500 2000 2500 Test Engineer: Todd Kruger Wt.Paint Fed(g.) Supervising Engineer: K.C.Kwok,Ph-D. - `� --'- I CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 e INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 17833 59TH AVE NE STE C Permit#:5605 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052200403900 DATE OF ISSUANCE. Scope of Work: Remove and replace two exhaust fans and collection filters for Valuation: 90000.00 existing fiberglass lamination processes using existing make-up air unit OWNER APPLICANT CONTRACTOR ARLINGTON ADVANCED Superior Systems Superior Systems MANUFACTURING PARK 3316 FUHRMAN AVE E STE 200 13576 Bayview-Edison Rd 13576 Bayview Edison Rd SEATTLE,WA 98102 Mount Vernon,WA Mount Vernon,WA 98273 425-212-8136 360-466-1234 LIC:SUPERS*196Q5 EXP:08/10/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: COMMERCIAL MECHANICAL CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I O/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales to urn form and coded City of Arlington#3101. 5 • Z O Z e7,l�l.Gt-O 09/25/2023 Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY COP/---1 RUCTION ON THE PUBLIC DOMAIN(Cli�3, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/25/2023 Processingrrechnology $25.00 09/25/2023 Exhaust/VentsNent Fans $30.00 09/25/2023 Mechanical Base $25.00 09/25/2023 Mechanical Commercial Plan Review $22.10 Total Due: $102.10 Total Payment: $0.00 Balance Due: $102.10 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail Permit#: 5605 Permit Date: 09/21/23 Permit Type: COMMERCIAL MECHANICAL Project Name: Fluid Motion Applicant Name: Superior Systems Applicant Address: 13576 Bayview-Edison Rd Applicant, City,Mount Vernon,WA State, Zip: Contact: Dennis Pearson Phone: 425-212-8136 Email: dennispearson@rangertugs.com Scope of Work: Remove and replace two exhaust fans and collection filters for existing fiberglass lamination processes using existing make-up air unit Valuation: 90000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/15/2023 Permit Expires: 05/13/2024 Form Permit Type: COMMERCIAL MECHANICAL Status: COMPLETE Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31052200403900 17833 59TH AVE NE STE ADVANCED 300 INDUSTRIAL/ C MANUFACTURING MANUFACTURING PARK Contractors Contractor Primary Contact Phone Address Contractor Type License License# Superior Systems Mack Wolfe 360-466-1234 13576 Bayview MECHANICAL L&I SUPERS*196Q5 Edison Rd CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C10. 12/01/2023 MECHANICAL 12/04/2023 12/04/2023 BUILDING Approved ROUGH-IN Plan Reviews Date Review Type Description Assigned To Review Status 09/22/2023 COMMERCIAL BUILDING Approved MECHANICAL Fees Fee Description Notes Amount Processing/Technology $25.00 ExhaustNentsNent Fans $30.00 Mechanical Base Permit Fee $25.00 Mechanical Commercial Plan Review Table 4-1 $904.57 Credit Card Service $2.40 Total $986.97 Attached Letters Date Letter Description 09/25/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/15/2023 XBP Con£ $80.00 158651151 11/15/2023 Dannis Pearson 158651151 Kristin Foster $2.40 11/15/2023 Fluid Motion,LLC 124141 Kristin Foster $904.57 Outstanding Balance $0.00 Uploaded Files Date File Name 11/15/2023 17494412-20231115 BLD5605 ApprovedDocuments.pdf 11/15/2023 17494410-20231115 BLD5605 IssuedPermit.pdf 09/22/2023 16968640-20230920 BLD5605 Anp Plans.pdf