HomeMy WebLinkAbout18012 GREYWALLS DR_BLD20100088_2026 CITY OF ARLINGTON
238 N.OLYMPIC AVE.-ARLINGTON,WA.98223
PHONE:(360)403-3421
— Permit#: BLD20100088
BUILDING PERMIT
Project Address: 18012 GREYWALLS DR, ARLWGTON
Parcel No: 00874800001400
PROPERTY OWNER APPLICANT CONTRACTOR
SALSTROM CHRISTOPHER A SALSTROM CHRISTOPHER A AIRFORCE HEATING&GAS
18012 GREYWALLS DR 18012 GREYWALLS DR 3810 166TH PL NE
ARLINGTON,WA 98223-5062 ARLINGTON,WA 98223-506 ARLINGTON,WA 98223-
Phone:(360)403-7697 Ext Phone:(360)403-7697 Ext. LICENSE#:AIREFFH942KA EXP:5/1/2012
Email: Email:
PLUMBING CONTRACTOR MECHANICAL CONTRACTOR
AIRFORCE HEATING&GAS
3 810 166TH PL NE
ARLINGTON,WA 98223-
Lic#, Ex p, Lic#:AIREFFH942KA Ex :5/1/2012
DESCRIPTIONJOB
REPLACE FURNACE UP TO 100BTU and Heat Pump
VALUATION: $0
PERMIT TYPE:Residential IPERMIT GROUP:Mechanical/Solar
NUMBER OF STORIES:0 TYPE OF CONSTRUCTION:
NUMBER OF DWELLING UNITS:0 OCCUPANT GROUP:
CODE:2006 OCCUPANT LOAD:
EXISTING AREA PROPOSED AREA
BASEMENT:0 1ST FLOOR:0 2ND FLOOR:0 BASEMENT:0 1 ST FLOOR:0 2ND FLOOR:0
3RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0 13RD FLOOR:0 GARAGE:0 DECK:0 OTHER:0
FRONT :ACK SIDE SETBACK REARSETBACK
REQUIRED: PROPOSED: RE UIRED: PROPOSED: I REQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O RE UIRED: PROPOSED:
SETBACK NOTES:
. .
OVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18:27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
Signature Print Name Date RE ed By ate
ATTENTION
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED.UBC109/IBC110/IRC110.
ARCHIVE APPLICANT ASSESSOR OTHER
i
BLD20100088
CONDITIONS
• None
Date Description Fee Amount Paid Balance Due
7/8/2010 C-Mechanical Permit Fee $70.00 $0.00 $70.00
Total Due: $70.00 $0.00 $70.00
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE
PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
INSPECTIONSCALL FOR
BUILDING/ENGINEERING/PARKS/UTILITIES/FINAL(360)435-0674
FIRE(360)403-3607
When calling for an inspection please leave the following information: Permit Number,Job Site Address,Type of Inspection
being requested,Contact Name and Phone Number,Date Prefereed and whether you prefer morning or afternoon.
• None
�1
i
' RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community Development
City of Arlington • 238 N Olympic Ave. •Arlington, WA 98223 • Phone(360)403 3551 • FAX(360)-443-344-7-
THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS, TWO(2) SETS
OF SPECIFICATION SHEETS AND TWO(2) SETS OF WASHINGTON STATE ENERGY CODE(if applicable).
Project Valuation. a
Project Address: Parcel ID#:
Lot#: Subdivision: /� /� /► sco
Project Description: r���vli f/��/l�l� /C CL" ' /_ ,�ry�� N� /_ —/l 31D �
Owner: '/,fS 7�� �������/J'� Phone Number: -&Q :2
Address: l •City: • LW—State:- -f— Zip/Code:
Contact Person: -7,/ Phone Number: 2610P "1d5-"/'�
Cell Phone: Fax: a31,1(1 �-[/1��- �'/rjk-mail:4,22�1Jv2a O
Address: 3 �� �� �l /4/r�A�ity: e Stater Zip Code: 45�A 2 -73
Please List quantity of fixtures Below:
CLOTHES DRYER _ _ FURNACE U TO 100K BTU GAS OUTLETS
FURNACE OVER 100K FLR FURN INSTAL-I/RELOCAI-E SUSPENDED HTR/UNIT HTR\
APPL VENT/OTHER APPLIANCE REPAIR BOILER UP TO 3 HP
BOILER UP TO 4-15 H BOLIER UP TO 16-30 HP BOILER UP TO 31-50 HP
BOILER 51 HP AND UP AIR AHNDLING UP TO 10K CFM AIRHANDLING OVER 10K CFM
EVAL COOLER VENTILATION FANS OTHER VENTILATION SYSTEM
VENT HOOD DOMESTIC INCINERATOR COM/IND INCINERATOR
ALL OTHER UNITS FREESTANDING STOVE FIREPLACE INSERT
Contractor: /,,�/ _Phone Number: �3�7� �/��� yw—s
Address: J Ya - FLU 47- City: State: Zip Code: �-173
Contractor's License Number: 47 /ram /6-2 Expiration: �� Z 2-
1 hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be in accordance with the laws, rules and regulation of the State of Washington.
Zz
Applica Ignature Date
111%� Z��141 , a
Print Applicants Name
/ FOR STAFF USE ONLY
'��b
Permit# Accepted By Amount Received Receipt# Date Received
WEB Forms-139 Page 1 of 1 04/08 sb
I
- � . �
r
1
.�
BLD20100088 (BFECHT/PT- -EVE) - PermitTrax by Bitco Software Page 1 of 1
>. BUILDING PERMIT PERMIT #: BLD20100088
� s
OWNER: SALSTROM CHRISTOPHER A-SALS... STATUS:APPLIED
�f + ADDRESS: 18012 GREYWALLS DR,ARLINGT... BALANCE: $0.00
ISSUED: CREATED: 7/8/2010
SCREENS:I Select Screen... FUNCTIONS: Select Permit Function... -(
MECHANICAUSOLAR
Reviews
ADD REVIEW REMOVE REVIEW PRINT CLOSE
Review Description Assigned To Due Date Last (#) Req? Done? ASSIGN
2000 C-Building I CYOUNG 7/15/2010 0 Y N ASSIGN
2008 C-Community Development I BFECHT 7/8/2010 0 Y N ASSIGN
http://coaweb2/pennittrax/PermitTraxMain/wfPermitConsoleReviews.aspx?COMMENT=R... 7/8/2010
.��
�• r
.�
I
1
FORM NO. G11-490
GAS FURNACES
/ 11
Pi esti e
0'
I
O
S E R I E S
SUPER QUIET 80
TWO STAGE
80% A.F.U.E.t
DOWNFLOW
0 GAS FURNACES
The Rheem Prestige Series® Super Quiet 80 Two Stage
Downflow line of downflow gas furnaces is designed for
installation in closets, alcoves, utility rooms, or attics.The
design is certified by CSA International.
Features
■ Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
MOW ■ Low profile"34 inch"[864 mm] design is lighter and eas-
ier to handle, and leaves room for optional equipment.
■ Energy efficient and quiet ECM 2+motor.
■ Improves cooling efficiency when matched with rated
condensing unit and coil.
■ Constant CFM.
RGLR- SERIES ■ Dip switch settings for selectable cooling airflow.
■ On-demand dehumidification terminal for improved com-
ECM Equipped fort in cooling mode.
Models with Input Rates from ■ Left or right side gas and electric inlet connections.
75,000 to 125,000 BTU/H R ■ All models feature an integrated board with humidifier and
> > electronic air cleaner hookups.
115 Volts, 60 Hz, Single-Phase ■ Insulated blower compartment, a slow-open gas valve,
[22 to 37 kW] specially designed draft inducer motor and blower motor
(U.S. & Canadian Models) make it one of the quietest furnaces on the market today.
■ Pre-paint galvanized steel cabinet.
■ Easy door removal and replacement.
o�„�H . , ■ Molded permanent filter.
y E
■ Compatible with single or two-stage thermostat.(For opti-
Sp Sp mal performance,two-stage thermostat recommended.)
HIGH A variety of cooling coils and plenums designed to use with
" Rheem Prestige Series®Super Quiet 80 Two Stage Down-
flow gas furnaces are available as optional accessories.
tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department
of Energy test procedures.
member
gania ,p
P2vvrae
� -
I
R H E E M . RESTIGE SERIES SUS . :"R QUIET 80
TWO STAGE
DOWNFLOW GAS FURNACE
IFC Integrated
Furnace Control
i
I_ `r
ECM Motor ti
f ECM Interface
Furnace Controls
Aft&,17'
P J t
:Aw '=
Two-Speed
Draft Inducer Motor
..iNy
. I
( Heat Exchanger
Pressure Switch In-Shot Burners
Flame Sensor �y
Direct Spark Ignitor
STANDARD EQUIPMENT All models can be converted by a qualified HVAC professional or local service
dealer to use L.P.(propane)gas without changing burners.Factory approved
Completely assembled and wired;2 speed induced draft blower;high and low kits must be used to convert from natural to LP.(propane)gas and may be
pressure switches;2 stage redundant main gas control;blower compartment ordered as optional accessories from a Rheem parts distributor.
door safety switch;solid state time on/time off blower control;limit control; For L.P.(propane)operation,refer to Conversion Kit Index Form.
transformer;ECM blower motor.Furnaces are equipped with cooling/heating
relay and transformer(40VA)ready for air conditioning applications.(Please NOTE:For natural and L.P.(propane)gas models,direct spark ignition is 100%
note:a thermostat is not included as standard equipment.)Flame sensor lockout type.
diagnostics;fused-protection(secondary),3rd speed option for continuous fan.
NOTE:Furnace is not listed for use with fuels other than natural or L.P.
(propane)gas. WAR.NING
The complete terms at limited and other warranties are available at our sales THIS FURNACE NOT "APPROVED
office,or through local installer. 1' RECOMMENDED
1 ' USE IN MOBILEHOMES
2 Rheem Manufacturing Company
..
r
BEFORE PURCHASING THIS APPLI` E, READ IMPORTANT ENERGY COST AND E'-'r,IENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS (DOWNFLOW)
U.S. AND CANADA MODELS
MODEL NUMBERS 07EAMKR 07EBROR 10EBRMR 12EARMR
RGLR-SERIES 07NAMKR 07NBRQR 1ONBRMR 12NARMR
100%High Input—BTU/Hr[kW]OO 75,000[22] 75,000[22] 100,000[29] 125,000[37]
High Heating Capacity—BTU/Hr[kW].7 60,000[18] 60,000[18] 80,000[23] 100,000[29]
70%Low Input—BTU/Hr[kW] 52,500[15] 52,500[15] 70,000[20] 87,500[25]
Low Heating Capacity—BTU/Hr[kW] 42,000[12] 42,000(12] 56,000[16] 70,000[20]
Heating—Ext.Static Pressure[kPa] .12[.029] .12[.029] .15[.037] .20[.05]
Blower(D x W)[mm] 11 x 7 11 x 10 11 x 10 11 x 10
[279 x 178) [279 x 254] [279 x 254] [279 x 254]
ECM Motor H.P.[W] 1/2[373] 3/4[559] 1 [746] 1 [746]
Motor Full Load Amps. 7.7 9.6 12.8 12.8
Unit Amps 8.7 12.0 12.0 12.0
Maximum Overcurrent Protection 15 15 15 15
Cooling CFM @.5"[kPa]E.S.P. 1200 1600 2000 2000
(Nominal)[Us] [566] [755] [944] [944]
Max.E.S.P.(In.W.C.)[kPa] 0.8[0.2] 0.8[0.2] 0.8[0.2] 0.8[0.2]
Temperature Rise I High Fire 30-60[17-33] 25-55[14-31] 30-60[17-33] 35-65[19.4-36.0]
Range°F[°C] Low Fire 20-50[11-28] 20-50[11-28] 25-55[14-31] 30-60[17-33]
Max.Outlet Air Temp.°F[°C] 165[73.9] 165[73.9] 165[73.9] 185[85]
Standard Filter Size—Inches (2)12 x 20 (2)14 x 20 (2)14 x 20 (2)14 x 20
[mm] 1305 x 5081 [356 x 508] [356 x 508] [356 x 508]
Approx.Shipping Weight(Lbs.)[kg] 1 115[52) 115[52] 120[54] 140[63]
AFUE( 80% 1 80% 80% 80%
O In accordance with D.O.E.test procedures.
O See Conversion Kit Index Farm for high altitude Berate in U.S.applications.For Canadian applications,reference the furnace installation instructions.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product Gas Heat Exchanger Limited Warranty......Twenty(20)Years
which fails in normal use and service within the applicable *Any Other Part.............................................Five(5)Years
period stated, in accordance with the terms of the limited *This five year limited warranty Is applicable only to single-phase
warranty. products installed in residential applications on or after January 1,2001.
For Complete Details of the Limited Warranty,Including Applicable Terms
and Conditions,See Your Local Installer cr Contact the Manufacturer for
a Copy.
MODEL IDENTIFICATION-DOWNFLOW MODELS
R G L R — 07E A M K R
Rheem Gas Downflow Design Heating Input Designation Variations Blower Heating&Cooling Fuel Type
Furnace Series Electric NOx Input A=Std. Designation Designation R=Natural Gas,
Ignition Model BTU/HR Cabinet U=11 x 6 K=600-1200 CFM U.S.and
B=Wide [279 x 152 mm] [283-566 Us] Canadian
07E 07N 75,000[22 kW]
07 E 07 N 175 Cabinet M=11 x 7 M=1200-2000 CFM Standard
12E 12N 100,000[,000[229 kW]kW] [279 x 178 mm] [566-944 Us] Furnace
R=11 x 10 0=1000-1600 CFM
[279 x 254 mm] [566-755 Us]
[ ]Designates Metric Conversions
Rheem Manufacturing Company 3
.I
I
DOWNFLOW DIMENSIUS
TIP BOTTOM ,`I—MI
I
RETURN24
g kt3t AIR
[622 m�J
3/' 201/1s"[713 mm]
A [19 mm]
R.A.
5 l'� 8 s/o"(16 mm] D I� 1_ 201/e" 516"
[16 mm] I 1 I [511 mmJ J16 mm]
AIRFLOW o /• 265/6„
119 mm] 1676 mmJ
265/6 112"DIA.[13 mm]
[676 mmJ
—-I- 7/e"DIA.
LOW VOLTAGE [22 mm]
ELECTRICAL I 34"
CONNECTION [064 mm]
(HIGH VOLTAGE) 233le" p p 233/e°
2613/16" [594 mm] 1594 mm]
1681 mm] 1518 m 2Q'M Ll
24�hs"m] 203/6 [tS21 mmJ
[518 mm]
GAS CONNECTION 63116" 63/16" 131s"DIA.
[157 mm] [157 mm] [35 mm]
LEFT SIDE FRONT RIGHT SIDE
DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL(INCHES) [mm]
MODEL REDUCED CLEARANCES(IN.)[mm]
RGLR- A B C D E LEFT RIGHT SHIP.WGTS.
SERIES SIDE SIDE BACK TOP FRONT VENT (LBS.)[kg]
07A 171/2[445] 1611/32[415] 121/a[308] D 165/8[422] 0 3 Cz 0 1 [25] 3[76] 6[152]03 110[49.9]
07B 21 [533] 1927/32[504] 137/e[352] 01 201/8[511] 0 0 0 1 [25] 3[76] 6[152]03 115[52.2]
10 21 [533] 1927/32[504] 137/e[352] 10 201/e[511] 0 0 0 1 [25] 3[76] 6[152]03 120[54.4]
12 241/2[622] 2311/32[593] 155/e[397] 10 235/e[600] 0 1 0 1 0 1 1 [25] 1 3[76] 1 6[152]c3� 140[63.5]
NOTES: 1T May require a 3"[76 mm]to 4"[102 mm]or 3"[76 mm]to 5"[127 mm]adapter.
TO May be 0"[0 mm]with type B vent.
OO May be 1"[25 mm]with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with
localcodes.
4 Rheem Manufacturing Company [ ]Designates Metric Conversions
t� � a�
.;,:.
c
BLOWER PERFORMP-ACE DATA DOWNFLOW IIADELS
BLOWER SIZE ECM CFM[L/sl AIR DELIVERY
MODEL RGLR- (D X W) MOTOR H.P. BLOWER EXTERNAL STATIC PRESSURE
INCHES[mm] [W] SPEED INCHES WATER COLUMN[kPal
.1 [.02]—.8[.2]
HIGH 1200[566]
07A 11 x 7 1/2 MED-HI 1000[472]
[279 x 178] [373] MED 800[378]
LOW 600[283]
HIGH 1600[755]
07B 11 x 10 3/4 MED-HI 1400[661]
[279 x 254] [559) MED 1200[566]
LOW 1000[472]
HIGH 2000[944]
10,12 11 x 10 1 MED-HI 1600[755]
[279 x 254] [746] MED 1400[661]
LOW 1200[566]
NOTE:See Coil Specification Sheet for coil data.
[ ]Designates Metric Conversions
Rheem Manufacturing Company 5
�� �--� �
' 11
f
ACCESSORIES DOW.r'''LOW
DOWNFLOW WARNING:Unit design is certified for installation on non-com- RXPF-F01 and F02
bustible floor.A special factory supplied combustible floor sub-base is
required when installing on a combustible floor.Failure to install the sub-base FOSSIL FUEL KITS—are for use with Rheem Heat Pumps and
may result in fire,property damage and personal injury. Super Quiet 80 warm air furnaces.The RXPF-F02 also meets TVA
requirements.
COMBUSTIBLE FLOOR BASE DIMENSIONS
COMBUSTIBLE USE WITH A B C RXGF-CC*
FLOOR BASE FURNACE SIZES IN.[mml IN.[mml IN.[mml FILTER RACK—Downflow top return mount.
RXGC-B17 RGLR-07EAMK 18 [457] 163/4[4251 143/4[451] NOTE:Filter racks are shipped without filters.
RXGC-821 RGLR-07EBRO, 211/2[546] 201/4[514] 181/4[464] "Filters available through PROSTOCKO.
RGLR-10EBRM
RXGC-624 RGLR-12EARMR 25 [635] 233/4[603] 213/4[552]1
FOR HIGH ALTITUDES:
HIGH ALTITUDE OPTION CODE:U.S.&Canada—
[ ]Designates Metric Conversions None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS:U.S.&Canada—
None required for high altitudes.
80+HIGH ALTITUDE INSTRUCTIONS
Caution:Always follow National Fuel Gas Code(NFGC)guidelines when
converting for high altitudes.High altitude option codes are not required for
19112„ these models.However,the burner orifice size needs to be recalculated
l�-1495 mm)—...j and verified at elevations above 2000 ft.See Installation Instructions for
q7'W
more information.
NOTE:For Canadian installations only,an optional Berate(manifold gas
c pressure reduction)method may be used to adjust the furnace for
altitude.See Installation Instructions for more information.This
optional method may NOT be used for U.S.installations.
.... RXGW-B01 CHIMNEY ADAPTER:
2Bz/e" ' �]721 mm] A � See Installation Instructions for application limitations.
li
%�3• 1']25 mm]
FIBERGLASS 3' '' _ _
3 LB.11.4 kg]DENSITY ]76 mm] FIBERGLASS
]51 mm)2" 3 LB.11.4 kg]DENSITY
`171FLOOR PLENUM OR
11:7-----
-•----- - --- 3")76 mm] DUCTWORK
L— WWI[646 mm] NOTE:FLOOR OPENING
21112„ 46 mm1 x B
MAX. LENUM SIZE
1911z"1495 mm]x C
6 Rheem Manufacturing Company
��• '� �'
�: 1
i
i
�I
1
NOTES
Rheem Manufacturing Company 7
,�
�i
Before proceeding with installation,refer RHEEM
to installation instructions packaged AIR CONDITIONING
with each model,as well as complying DIVISION
with all Federal,State,Provincial,and
Local codes,regulations,and practices. 5600 Old Greenwood Road,Fort Smith,Arkansas 72908
"In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice."
PRINTED IN U.S.A. 5-06 DC FORM NO. G11-490
.-u'-
.; f�
��r • �
• , I
1
I�
I
I
FORM NO. P11-780 REV. 1
Supersedes Form No.P11-780
EA
PUM
Equipped withy ,
the Aware! Winning WS✓F ,,,.Q
Comfort Control Systemrm e
• Increased Reliability
0
•On-Board Diagnostics
•Fault Recall Pre.stz e
•Active Protection- S E R I E S
v \ RPQL- JEZ n 'f �/a� The Rheem Prestige Series'^t RPQL- JEZ Heat Pump Outdoor
Ldi G � ? units can provide year-round heating and cooling comfort for resi-
15 SEER Models denlial, multi-family and light commercial applications. They are
" Efficiencies up to 15.5 SEER/13 EER/10 HSPF
esigned to operate with Rheem indoor units with Nominal Sizes 11/2 to 5 Tons heating capacities certified under the ARI Certification program.end
[5.28 kW]to [17-6 kW] The following additional features,plus its energy-saving character-
Seven Models istics,make the RPQL-JEZ Heat Pump outdoor unit an excellent
choice for new construction or upgrading your present system.
Cooling Capacities The Rheem Prestige Series"'"RPQL-JEZ Heat Pumps are the
18,300 to 60,500 BT'U/HR result of an ongoing development program for improved efficien-
[5.36 kW]to[17.73 kW] cies. With SEER's up to 15.5, these units continue a tradition of
HSPF up to 9.00 high efficiency.
■The Comfort Control Systeml^t provides on-board diagnostics
and fault history for heat pumps with single-phase compressors
by detecting system and electrical problems without adding sen-
sors.It can also communicate"fault codes"to enabled 1 terminal"
thermostats. The Integrated diagnostics with Active Protection
prevents compressor operation when potentially harmful condi-
tions are detected.
■7-Segment LED Display is exclusive only to Rheem products.
The information-display quickly and accurately shows technicians
the source of malfunctions.
■Features a five-year conditional unit replacement warranty
when properly Rheem installed
l door Coil w th a Rheem Gas Furnace,Air Handler OR
_ti-yam9 Compressor sound blanket is standard to provide quiet operation.
0 Attractive,louvered wrap around jacket protects coil from weather
extremes and yard hazards.Top grille is steel reinforced for extra
strength.Cabinet is powder painted for all weather protection.
■Four sided outdoor coil design allows compressor operation with
access panel removed.
■Air is discharged upward away from bushes and shrubs.The dis-
. Charge pattern of the top grille provides minimum air restriclion,
- -' resulting in quiet fan operation.
■Combination Grille/Motor Mount secures the fan motor to the
underside of the discharge grille.
(J,(J �i16 C�`' ��G e ■Removable top grille provides access to the outdoor fan motor
and outdoor coil.
•Compressor compartment offers additional protection from the
elements and reduces operating noise.
s Single speed, 8-pole fan motor is designed for quieter, energy-
saving operation.
■Non-cycling reversing valve and demand defrost.
,P/f GOR'lAF-C• a All models meet or exceed a 1000-hour salt spray test perASTfJI
B117 Standard Practice for Operating Salt Spray Testing
Apparatus.
C us
ISO
(E)
r.,. LISTED
Proper sizing and installation of equipment/s critical to achieve optimal performance.Splir Sys lam air condltlonars and hoar pumps must he matched wlthren•
appropriate col/components to meet ENERGY STAR cnrario.Ask your Contractor for dot it S sl visit ww comfit
ionarsa nd h nt pu ips musrorgystacgod will,
�1,
'4V
1
FEATURES & BENJITS OF THE COMFORI CONTROL TM
�The Rheem exclusive 7-Segment LED Display easily shows s stem � �or` SYSTEM
y The fault recall feature will allow for the last six fault-codes to be
operating status codes and diagnostic codes.
' displayed,and will retain these codes even if power failure occurs.
A Sealed Switch replaces the standard
'1 .r contactor and fea- 'Built-in short-cycle protection allows the compressor to restart eas-
�� tures optical control ily without oil removal.
�^ and latching mocha- 'A 30-second minimum run-time for every compressor call enables
nism.The sealed ., oil to return to the compressor.
switch prevents infil- a
' Active Protection monitors the system to prevent nuisance lockouts
[ration of insects and and prevents compressor operation
dust.A minimal " when potentially harmful conditions
switching arc,by the are detected.
Optical control,offers ■The compressor and fan are controlled
surnes less power while reducing chatter. independently,which reduces the
greater reliability.The latching mechanism con-
INThe Status Indication and System Diagnostics feature thermostat a starting load and light dimming. -�
communication capability,built-in diagnostics,high&low voltage A manual push-button is offered to �►
9 operate the compressor and fan for 5
monitoring and high&low pressure switch monitoring.The thereto-
slat communication capability alerts the homeowner to any necessary checks to allow for an operation
service requirements.Faster,more accurate L
service is provided by the built-in diagnos- a in order to save time and mone tics,by providing tile y,
e HVAC professional replacement automotive fuses can be
with dependable information.With the high � U!ffized Instead of replacing the entire control board.
and low voltage monitoring feature,the con-
trol provides alerts for out-of-range condi-
tions.In addition,high and low pressure- Problem-S olvin Accuracy
switch monitoring prevents the system from
operating outside of its normal parameters. 1C09i
STANDARD FEATURES ' - -
R PQL-JEZ Heat Pump Outdoor Units
1. Scroll compressor is hermetically sealed and incorporates internal
high temperature motor overload protection,and durable insulation 49% ■ ism D Orroa,i
on the motor windings.It is externally mounted on rubber grommets to reduce vibration and noise. F�'04Vv C;"1,A
2. Enhanced Compressor Protection—Features an enhanced 20% {aaYaraE•.4 m
defrost control,auto-reset high pressure control,and auto-reset
low pressure control to provide compressor protection under 0%
abnormally high head pressure conditions(outdoor fan failure, fttFy
restriction,dirty coil,etc.)or abnormally low suction pressure condi- Ltl Expgirienc9rd
tions(restrictions,TEV failure,loss of charge,indoor blower failure,
etc.)while eliminating nuisance!ripping sometimes experienced with
conventional control systerns.3. Compressors have an internal pressure relief assembly to protect SCROLL 0C0MPRESS0R
against excessive pressure differential.
4. All refrigerant connections are on the exterior of the unit,located The scroll compressor is the key to efficiency for this Rheem model.It's
close to the ground for neat appearing installations. the latest in high-efficiency compressor technology.The advanced scroll
5. Cabinet is constructed of powder painted galvanized steel,The full
compressor offers low noise and vibration characteristics and features
wrap-around louvered grille protects the coil from damage, tolerance to liquid refrigerant and system contamination.The scroll
6. Enhanced compressor sound blanket is standard. compresor also has low start torque,eliminating start problems in the
7. Demand Defrost Control—Provides complete defrost when defrost
field.And its unique design enables the RPQL-JEZ Neat Pump to
is required. perform efficiently,quietly and dependably.
8. Non-Cycling Reversing Valve—Eliminates discharge noises on
each heating cycle.
9. Hot Gas Muffler—Reduces noise in heating cycle.
10. Bi-Directional Filter Drier—Standard on RPQL-JEZ models
(shippers—net installed).
11. Service valves are standard on all models.
12. Refrigerant Metering—TEV accurately meters refrigerant into
indoor and outdoor coils.
13. Copper tube—aluminum fin coils are used on all models.
14. The control box is located in the top corner of the cabinet providing
for easy access through a service panel.
15. Service valves are standard on all models.
16. Field connections for power and control wiring are kept separate.
17. Every unit is factory charged and run-tested.
18. Separate compressor compartment for easy service access.
19. Drawn,painted basepan for extra corrosion resistance and sound
reduction.
20. The RPQL-JEZ has a 10 year limited compressor warranty,plus a
5 year conditional unit replacement warranty.See General Terms of
Limited Warranty for more details.
21. Hard Start Kits—Standard on all JEZ models.
22. Control[lox Cover.
2 Rheem Heating, Cooling and Water Heating
.},
r,
1
1
I
n i
,c
Model Number Identification
R P a L — 018
� E Z
RHEEM REMOTE Q=15 SEER DESIGN COOLING
ELECTRICAL VARIATIONS COOLING
HEAT PUMP SERIES CAPACITY
DESIGNATION E=EQUIPPED WITH CONNECTION
L=R-410A 018=18,000 BTU/HR JT03 kVJJ J=208/23OV-1-60 THE COMFORT FITTING
024=24.000 BTU/HR [7.03 kWJ CONTROL SYSTEM' Z=SWEAT
030=30,000 BTU/HR [8.79 kW] W/SCROLL
036=36,000 BTU/HR[10.55 kW]
042=42,000 BTU/HR[12.31 kWJ
048=48,000 BTU/IJR[14.07 kWJ
060=60.000 BTU/1IR[17.58 kW] I ]Designates Metric Conversions
Field Installed Accessories _-
is Low Ambient Control—Allows low temperature operation in the cooling r Compressor Crankcase Heater—Available through PROSTOCK6,
cycle down to 0°F[-17.8,C)outdoor temperature.It is recommended that ■ Thermostats and-Subbases—Available through PROSTOCK®.
this control be Insta!!cd in units to be uperated for cooling at outdoor
ambient temperatures under 70"F[210C].(Model No.RXAD-A00) ° Blower Time Delay Control—RXMD-004.
■ Thermostats a Fossil Fuel Kits—RXPF-01
RXPF-02
G t
I.
• I D
lip
300-Series * 200-Series * 100-Series
Deluxe Programmable Programmable Non-Programmable
400-Series*
Special Applications/Programmable
Unique
Brand Model DascrlPtor Series System)
Number (3 Characters) (3 Characters Type
Prefix (2 Characters) T(2 Characters)
RHC - TST 101 GE MS
3:i7'=Then�osr.v 100-Nen-Prugraevpabla GE=GwOII/El.ddc Ss=Single-slag.
200Pro9rornmAk HP=Heal Pump MS=MuNSIe
9e
RHC=Rheem ]OODeluxe Pr ogramsahte MD=Modulatlne Furnace
400-SPo gApp*,ewGal
Prog.ammado DF=Duel Fuel
uti-Urworul ACrHPn'E
"Photos are representative.Actual models may vary.
For detailed thermostat match-up information,
see specification sheet form number T11-001.
Rheem Heat Pump System
More than a reverse cycle air conditioner,it's a specially designed combination Winter/Summer comfort system using a single indoor coil
for heating and cooling.
For all season home comfort,performance and energy conservation,choose a Rheem RPQL-JEZ Heat Pump and a RHSL, RHLL,or
RHKL Series Air Handler.
To choose an Air Handler designed for use with the RPQL-JEZ Heat Pump, refer to the Performance Data Tables and/or the air handler
specification sheet.
Rheem Heating,Cooling and Water Heating 3
• '1• -
:.
.r-.
��
I
I
Performance Data ARI StanL_.rd Conditions-RPQL-JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Model Numbers ARI Coolln Perlormance ARI Healln Performance 70°F(21°Cl indoor
80°F[26.5°C]DB/67°F[19.5°Cl WB Indoor Air OuldocrAir Outdoor 95°F[35°Cl DB Outdoor Air
Outdoor 47°F(8,5°C]BB/ 17°F(-8.b-C]C10B/ DOE
Indoor Total Net Net 43°F[6°C1 WB 15*F(-9.5°C1 WB R
Unit Coil and/or Capa epi on
icily Sens. Latent Snd. Indaor DOE High Temp. DOE Low Temp, IY
RPOL- Air Handler 8 U/H BTU/H BTU/H EER SEER Rate CFM
ikWI IkWI (kWl dB 1L/s] [kU/ COo BTU/H HSPF
Rev. 1kW1 COP
11/14/08 RHLL HM2417(RCSL H*2417A*)0 i[5 51 00 1[4 2510 [j33i 13.00 15.50 70 625 17,200 4 02 10,400 2.60 9.50
[295] [5.0) [3.0]
RCFL H*2414A* 18,300 13,950 4,350 650 17,800 10,900[5.4] 14.1] [1.3) 11.50 14.00 70 1307 3.68 2.38 9.50
] [5.2] [3.2]
RCFL-H*2414A*(RGFD-06?MCK?) 18.400 13,950 4,45] 600 17,200 1[5.4] [4,1] [1 0,400
.3 12.G0 15.50 70 [283] [5.0] 4.00 2.56 9.50
18,400 13,950 4,450 [3.0]
RCFL H*2414A*(RGFD 07?MCK?) 12.00 15.50 7p 600 17,200 10,400[5.4j [4.1] [1.3] [283] [5.0] 4.00 (3.0] 2.56 9.50
RCFL-H*2414A*(RGGD-06?MCK?) 18.400 13,950 4.450 600 17,200 10,400
[5.4] [4.1] [1.3] 13.00 15.50 70 [2831 [5.0] 4.04 [3.0 2.58 9,50
18,700 14,350 4,350 ]
RC,c L H*241,A*(RGGD-G7?MCK?) [5.51 [4.21 [1.31 13.00 15.50 70 625 17.200 402 10,400 2 58 9.50
[295] [5.01 [3.0]
RCFI-H"2414A*(RGJD 06?;°1CK?) 1[5 41U 1[4910 �1.31 13.00 15.50 70 600 17,200 4.04 10.400 2.58 9.50
[283] (5.0] [3.0]
RCFL-W2414A*(RGJD-07?MCK?) 18,700 14,350
4,35 625 17,200 4 02 10,400 2 58 9.50
13.00 15.50 70 [2951 [5.0] [3,0]
RCFL-H*2414A*(RGLR-07?AMK?) 18,500 14,0] [45 600 17,200 10,400
13.00 15.50 70 [283] [5.01 4.04 [3.0]18,400 13,950 4450 2.58 9.50
,
RCFL-H*2414A*(RGPR-05?BMK?) [5.4] [4.1] [1,3] 12.00 15.50 70 60D 17,300 398 10,500 2.56 9.50
[283] [5.1 J [3.11
RCFL-H*2417A* 18,300 13,950 4,350 650 17,800 10,900
] [5.21 [3.2
018JEZ [5.4] [4.1] [1.3] 11,50 14.00 70 [307 3.68 ] 2,38 8.50
RCFL-H*2417A*(RGFD-06?MCK?) 1[5.4] 13,950 j 0 [45 12.00 600 17,200 4.00 10,400 15.50 70 12831 [5.0] [3.0] 2.56 9.50
RCFL-H*2417A* (RGFD-07?MCK?) 18,400 13,950 4,450 600 17,200 10,400
] [4.1] [1.3] 12.00 15.50 70 [283] [5.01 4.00 [3.0] 2.56 9.50
RCFL-1-1*2417A*(RGGD-06?MCK?) 18 500 14,050 4,450 600 17 10,400,200
[5.4] [4.1] [1.3] 13.00 15.50 70 [283J [5.0] 4.04 [3,0] 2.58 9.50
RCFL H*2417A*(RGGD 07?MCK?) 1[5 51 700 1[4 21 [t 3j 13.00 15.50 70 625 17,200 4 02 10,400
RCFL H*2417A*(RGJD 06?[viCK?) 18,500 14,050 4,450 [295] [5.0] [3.0] 2.58 9.50
[5.41 [4.1] [1.31 13.00 15.50 70 600 17,200 4.04 10,400 2 58 9.50
[283] [5
RCFL-HW2417A*(RGJD-07?MCK?) 18,70 5J 14,350
[4.21 4,3g 13.00 15.50 70 625 17,200 4 02 10,400 2 58 9.50
[295] [5.0] [3.0]
RCFL-H2417A*(RGLR-07?AMK?) 18,500 14,050 4,450 600 17,
[5.4] [4,1] [13] 13.00 15.50 70 200 10,400
[283) [5.01 4.04 [3.0] 2.58 9.50
RCFL-H*2417A*(RGPR-05?BMK?) 1[5.4]400 13,950
4,45 600 17,300 10.500
12.00 15.50 70 [283] [5,1] 3.98 2.56 9.50
, [31)
RCFL H 18,500 14,050 4450
*2417A*(RGPR 07?AMK?) [541 [4.11 [1.3] 13.00 15.50 70 600 17,200 4 02 10,400 2.58 9.50
[2831 [5.0] [3.0]
RHKL HM2417(RCSL H*2417A*) 1[5 5]0 1[4 2]350 [;3, 625 17,200 4.02 10,400 2.58 9.50
13.00 15.50 70
[295] [5.0] [3.0]
RHSL HM1817(RCSL H*2417A*) 1[5 3j0 1[4 01 750 4,350 600 17,600 3 78 10,800 2,44 9.00
12.00 14.00 70 [283j [5.2]
* 24,000 17,950 6,050 (3-2)
RHLL HM2417(RCSL H 2417A*)» [7.01 [5.31 [1.8] 13.00 15.00 70 [800 23,000 3.72 13,900 2.44 9.00
RCFL-H*2414A* 23.600 17,550 6,050 11.50 14.00 7p 800 23,600 14,500[6.9) [5.1] [1.8] [3781 [6.9] 3.48 21 2.30 8.50
23,800 17,800 6,000 4 0
RCFL H*2414A*(RGFD 06?MCK?) 12.00 14.50 70 800 23,200 14100
024JEZ [7.0] [5.2] [1.8] [378] [6.8] 2.62 14.11 2.40 8.50
RCFL-H*2414A*(RGFD-07?MCK?) 24,000 0) 17 5 ,8] 800 23G o00 14 000
12.00 14.50 70 3.64 2.40 8.50
[378] i,,.,,1 [4.11
RCFL H*2414A*(RGGD O6?MCK?) 2[7�1 17,950 [1 Qj 13.00 15,00 70 800 23,000 3 68 13,900 2.42 9.00
RCFL H*24i4A*(RGGD 07?MCK?) 24,OD0 i7,950 6,05 [378] [6.7] [4.1]0 800 23,000 14000[7.0] [5.3] [1.8 12.00 15.00 70 3.66 2.42 9.D0
O Highest sales volume tested combination required by DOE test procedures. 1
[ ]Designates
Metric Conversions
4 Rheem Heating,Cooling and Water Heating
�_ 1 �
4�
��1
�'i
Performance Data ARI S>`_ "dard Conditions-RPQL-JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Model Numbers ARI Cooling Performance ARI Healin Performance 707121°C]Indoor
80°F[26.5`Cl DB/67°F[19.5°C]WB Indoor Air Outdoor Air Outdoor Air
951 I35°Cl DO Outdoor Air 47°F(8.5*C)DB/ 177 I-8.5*CI DO/ DOE
Outdoor Indoor Total Mel Net 437I6^Cl WB 15°F[-9.5°CI WB Ile i
on
Unit Coil and/or Capacity Sens. Latent Snd. Indoor DOE High Temp. DOE Low Temp. IVRPQL- Air Handler BTU/H BTU/H BTU/H EER SEER Rate CFM H BTU/H HSPF
TU/
IkWI [kWI [kW) d8 IL/sl B TU/ COP IkW) COP
11//l4/08 RCFL-H*2414A*(RGJD-06?MCK?) 24,000 17,950 6,050
[7.01 [5.3] [1.81 13.00 15.00 70 [378] 2[60] 3.68 1[49]D 2,42 9.00
RCFL H*2414A*(RGJD 07?MCK?) 2[7.0]
7 3]0 1[53]0 6,05
,8] 12.00 15.00 70 800 23,000 3.66 14,000 2 42 9.00
[378] [6.7] [4.1]
RCFL H*2414A*(RGLR 07?AMK?) 2[700] 1[5 3]0 6,050
.81 [8000J 2[3,0 13,900
13.00 15.00 70 2.70 2.44 9.00
[4.1 J
RCFL H*2414A*(RGPR 05?BMK?) 2[7 p]U 1[53;D I'All$] 12.00 14.50 70 775 23,200 2.64 14,000 2.40 8.50
[366] [6.8]
(4.11
RCFL H*2417A' 2[9j0 1[5150 6,050 11.50 14.OD 70 800 23,600 14,500
] [1.8] [378] [6.9] 3.48 [4.21 2.30 8,60
RCFL-H*2417A*(RGFD-06?IMCK?) 23,800 17800 [000] 800 23,200 i4,100
12.00 14.50 70 2.40 8.50
(3781 [6.81 2-62 14.1]
RCFL-H*2417A*/nGFD 7 24000 17950 6,05u l�uru ui rPviCK?) [7.0] 15.31 [1.8] 12.00 14.50 70 800J 23,200
3.64 14,010 2.40 8.50
[378
1`10FL-1-1*2417A*(RGGD-06?MCK?) 24,000 17,950 6,050 800 23,000 13,900
024JEZ [7.0] [5.3] [1.8] 13.00 15.00 70 [378] [600 3.68 [411 2.42 9.00
RCFL-H*2417A*(RGGD-07?MCK?) 24,000 17,950 6,050 800 23,000 14,000[7.0] [5.3] [1.8] 12.00 15.00 70
[378] [6.7] 3.66 [4.11 2.42 9.00
RCFL H*2417A*(RGJD O6?MCK?) 2[7 0]000 1[7 955 31D 6,050 13.00 15.00 70 800 23,000 3 68 13,900 2 42 9.00
[378] 16.7j [4.1]
RCFL-H*2417A*(RGJD-07?MCK.?) 2[7 01 17, 0 6,050
j 8] 800 23,000 3.66 14,000 2 42 9.00
12.00 15.00 70
3] [378] [6.7]
24,000 17,950 6,050 [41]
RCFL H*2417A*(RGLR 07?AMK?) [7.0] [5.3] [1.8] 13.00 15.50 70 800 23,000 2 70 13,900 2.44 9.00
[3781 [6.7] [4.1]
RCFL H*2417A*(RGPR 05?BMK?) 24,000 O 1[5 3]950 [1 8] 775 23,200 2 64 14,000 2.40 8 50
12.00 15.00 70 13661 [6.8]
14.1]
RCFL H*2417A*(RGPR 07?AMK?) 2[7 01 000 1[5 3]U [1.81 13.00 15.00 70 (3800 78J 23,000
2.68 13,900 2.44 9.00
RHKL-HM2417(RCSL-H*2417A*) 24,200 18,300 5,90] 378 2[6.71 1[4.1]
[7.11 (5.41 [1.7 13.00 15.00 70 [401] [6.7j 3.68 2.42 9.00
23,800 17,800 6,000 [41]
RHSL HM2417(RCSL H*2417A*) [7.01 [5 21 [i 8] 12.00 14.00 70 800 23,400 14.300
(3781 (6.91 2.52 [4.21 2.34 8.50
RHLL HM3617(RCSL H*3617A*)O 3[8 8] 2[fi 4] 8,100
2 4] 1,000 29,000 3 82 2.60 9.00
13.00 15.50 71 18,300
[4721 [8.5]
[5.4]
RCFL-H*3617A* 29,600 21,500 8,100 1,000 29,600 18,900[8.7] [6.31 (i4l) 11.50 14.00 71 1,00[472 [8.7],60 3.6U 2.44 9.00
29,600 21,600 8,000 [5.51
RCFL H*3617A*(RGFD O7?MCK?) [8.7] [6.31 12.00 14.50 71 1,000 29,200 18,600] [2.3j (472] [8.61 3.70 [5.4] 2.50 9.00
RCFL-H*3617A*(RGGD-06?MCK?) 29,80 21,800 [2 3] 12.00 14.50 71 1,000 29,200 3 72 18,600 2 52 g.00
[472] [8.6] [5.4J
RCFL-H*3617A*(RGGD-07?MCK?) 29,600
21,600 [2 30 1,025 29,400 3 70 18 600 2.50 9.00
12.00 14.50 71 [484] [8.6] 8,6
29 800 21 800 8 000 J
RCFL H*3617A*(RGJD 06?MCK?) 12.00 14.50 71 1,000 29,200 18,B00
030JEZ [8.7J [6,4J [2.3J [472) [8.6] 3.72 [5.41 2.52 9.00
RCFL-W3617A*(RGJD-07?MCK?) 29,600 21,600 8,000 1200 14.50 71 1,025 29
. ,400 18,600[8.71 [6.3] [2.3] [484]
RCFL H*3617A*(RGLR 07?AMK?) 2[�]0 2[641 [�4j 1,025 29,200 376 18,500 2.54 9.00
11.50 15.00
8, [5.4]
RCFL H*3617A*(RGPR 05?BMK?) 29,600 21,600 000
[8.7] [6.3] (2.31 12.00 14.50 71 1,000 29,400 3 70 18,600 2.50 9.00
[4721 [8.6] [5.4]
RCFL-H*3617A*(RGPR-07?AMK?) 29.800 21,750 8,05] 1,000 29,200 18,500[8.7] [6.4] [2.4 12.00 14.iO 71 1472 3.76
j [8.6] [5.4] 2.54 9.00
RCFL-H*3621A* 29,600 21.500 8,100
[8�1 11..90 14.00 71 1,000 29.600 18 900
[6.31 [2.4] [472] [8.7] 3.60 [5.5] 2.44 9.00
RCFL W3621A*(RGFD-07?MCK?) 29,800 21,800 8,000 1 000 29,200 18600
[8.7] [6.4] [2.3] 12.00 14.50 71 [4721 [8.6] 3.72 [5.4 2.52 9.00
D Highest safes volume tested combination required by DOE test procedures. ]
[ ]Designates Metric Conversions
Rheem Heating, Cooling and Water Heating 5
i��
_� �.
��
� I
».
1
�I
I
I
1`
'�L
I
Performance Data ARI Stan,--i'd Conditions-RPQL-JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Model Numbers ARI Conlin Performance ARI Heatin Performance 7g•F!2 I Q Indoor
80°F[26.5°C]OB/67°F[19.5°C]We Indoor Air Outdoor Air Outdoor Air 95°F[35°C]DB Outdoor Air 47°F 18.5°C)De/ 17°F[-8.5°C]DB/ DOE
Outdoor Indoor Total Net Nal 43•F[6°C)WB 15°F[-9.5°Cl WB Unit Coil and/or Copaclly Sens. Latent Snd. Indoor DOE High Temp. p0E Low Temp, Region
RPQL- Air Handler BTTU/H BTUlH BTU/II EER SEER Rate CFM BH COP BTU/H COP HSPF
[kW) IkWI IkWj dB [1.7s] TU/TU/(kW [kWl
Rev RCFL-H*3621A* RGGD-06?MCK? 29,800 21,750 8,050
11/14/OB ( ) 12.00 14.50 71 1,000 29,200 18,500[8.7j (6.4] [2.4) (472j [8.6] 3.74 2.52 9.00
29,800 21,800 8,000 [5.4J
RCFL H*3621A*(RGGD 07?MCK?) [8.7] [6.4] [2.3] 12.00 14.50 71 1,025 29,200 3 72 18,600 2 52 9,G0
14841 [8.6] 15.41
RCFL H*3621A"(RGJD 06?MCK?) 2[$$) 2[64;D [2 41 12.00 14.50 71 1,000 29,200 3,74 18,500 2.52 9.00
[472] [8.6] [5.4]
RCFL H*3621A*(RGJD 07?MCK?) 2[8�� 2[6.4]0 [2 3] 1,025 29,200 3 72 18,660 2 52 9.00
12.00 14.50 71 [484] [120 8,6
29,800 21,750 8,050 [5.4]
RCFL H*3621A*(RGLR 07?AMK?) [8.7] [6.4] 12 4) 12.00 15.00 71 14845 29,200 3 78 18,400 2.54 9.00
[ ] [8.6] [5.4]
030JEZ RCFL FI*3621A*(RGLR 07?BRC1?) 30,.8] 269G0 8,100 1 000 29,000 18,300
13.00 15.50 71 [472
[8.8] [6.4] [2.4] ] [8.5] 3.84 [5.4] 2.58 9.00
RCFL H*3621A*(i4GFR 05?"oiviK?) -2[$6 j0 2[6.31. [2 3] 12.00 14.50 71 1,000 29,200 3.70 18,600 2.50 9.00
[472] [8.G] [5.4]
RCFL-H*3621A*(RGPR-07?AMK?) 29,800
21,750 8,050
2 4j 14700 29,200 3 76 18,400 2 54 9.00
12.00 15.00 71 [ ] [8.6]
[5.4]
RCFL H*3621A*(RGPR 07?BRQ?) 3[8 Bj0 2[G.4]900 8,100
2 q) 1,000 29,000 3.84 18,200 2.58 9.00
13.G0 15.50 71 [472) [8.51 [5.3]
RHKL HM3617(RCSL H*3617A*) 3[8 8] 2[13A]]0 8,100
�4� 1,025 29,000 3.82 18,300 2.56 9.00
13.00 15.50 71 [484] [8.5]
29.400 21,250 8,150 [5.4]
RHSL-HM3017(RCSL-H*3617A") - (8 6] (6 2 12.00 14.00 71 950 29,400 18,700
[2.4] 1448] [8.6) 3.66 [5.51 2.48 9.00
RHLL-HM3617(RCSL-H*3617A*)0 [6,6]200 2[7 450 9,750 1,200 37,000 24,000
] [2.9] 13.00 15.50 74 [566] [10.81 4.02 2.82 10.00
[7.0]
RCFL-H*3617A* 34,400 24,650 9,750 11.50 14.00 74 1,075 37,600 24,600
[10.1] [7.2) [2.9] [507] [11.01 3.84 [7.�1 2.70 9.00
RCFL-H*3617A*(RGFD-09?ZCM?) 00[60 6J 26,900
[2 70 1,150 37,200 3 96 24,200 2 78 10 00
12.00 15.00 74 [543] [10.9] [7.1
36,200 27,050 9,150 ]
RCFL H*3617A*(RGFD 10?ZCM?) [10.6] [7.9] [2.71 12.00 15.00 74 1,175 37,200 3.92 24,200 2 76 10.00
[554] [10.91 [7.1]
RCFL-H*3617A*(RGLR-07?AMK?) 36,7] 27,350
91050 12.00 14.50 74 1,200 37,400 24 q00
[566] [11.01 3.90 [7.11 2.74 10.00
RCFL-H*3617A*(RGPR-07?AMK?) [6,6)200 27,20 �2 6� 12.00 14.50 74 1,200 37,400[566] 388 24,400 2.74 10.00
RCFL-H*3621A* 34,400 24,650 9,750 1,075 37,6[11.0] 40
00 24,600
[10.1 J [7.2] [2.9] 11.50 14.00 74 [507] 111.0] 3.84 17.21 36,200 26,900 9,300
2.70 9.50
RCFL H*3621A*(RGFD 09?ZCM?) [106) (,9] [2 7] 12.00 15.00 74 1,150 37,000 24,200
[543] [10.8] 3 08 [7.1] 2.80 10.00
036JEZ RCFL-H*3621A*(RGFD-10?ZCM?) 36,00] 2[8 5] 9150
12.00 15.00 74 1,175 37,200 394 24,200 2.76 10.00
[5541 [10.9] [7,1]
RCFL-H*3621A°(RGGD-09?ZCM?) [6040] 27 0] �20] 12.00 15.00 74 1,175 37,200 3 98 24,200 2 78 10.00
[554] [10.9] [7.1]
RCFL-H*3621A*(RGGD-10?ZCM?) 36,400 27,200 9,200[10.71 [8.0] 1,175 37,000 24,200
12.00 15.00 74
[2.7] [5541 [10.81 3.98 (7 11 2.80 10.00
RCFL-H*3621A*(RGJD-09?ZCM?) f60 7]400 2[j.01 0 9,200 1,175 37,200 24,200
12.00 15.00 74 [554] [10.9]
[2.7] 3.98 [7.1] 2.78 10.00
RCFL-H*3621A*(RGJD-10?ZCM?) 36,400
6�0, 2[82010 [2 00] 12.00 15.00 74 1,175 37,000 3 98 24,200 2 80 10.00
[554] [10.8] [7.11
RCFL-H*3621A*(RGLR 07?AMK?) [60 7]400 27,350[8 0) [2 71 12.00 15.00 74 1,200 37,400 3 90 24,400 2 74 10.00[566] [11.0] [7•1]
RCFL H*3621A*(RGLR 07?BRQ?) [608] 2[88 j0 [261 13.00 15.50 74 1,225 37,000 3 q8 24,000 280 10.00
[5,8] [10.8] [7.0]
RCFL H*3621A*(RGLR 10?BRM?) 110 7] 2[g5] 9`00 13,00 15.50 ,4 1,200 37.000 4 00 24,000 2.80 10.00
[566] [10.8] [7,0]
RCFL-H*3621A*(RGPR-07?AMK?) 36,400 27,350 9,050 1 200 37,400 24400
[10.7) [8.0) [2.7) 12.00 14.50 74 [566 3.90 2.74 10.00
H0 Highest sales volume tested combination required by DOE test procedures.
[ ]Designates Metric Conversions
6 Rheem Heating, Cooling and Water Heating
- ---«---
��J
� 1 �
1rM
Performance Data ARI Sil lidard Conditions-RPOL-JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Model Numbers ARI Cooling Performance ARI Healin Performance 0 :I21*CI Indoor
8117 126.5 C)DB/67°F[19.5•CI WB Indoor Air Ogldoor Air Outdoor Ali
95'F 135•CI DB Outdoor Air 47°F(8.5•C)DB/ 17'F(-B.5°C)OB/ DOE
Outdoor Indoor Totet Net Net 43•F[li WB 15'F(-9.5°C)WB Region
Unit Coil and/or Capachy Sons. talent Sad. Indoor DOE High Temp. DOE Low Temp. I
RPQL- Air Handler BTUII� BTU/H BTU/H EER SEER Rate CFM gTUlH
IkW) III [kW) dB rL/s) TU/ COP BTU/H HSPF
Rev. Ift cut•
11/14/08 RCFL-W3621A*(RGPR-07?BRQ?) 366
0�0 2[7.50 �2 0 1,200 37,000 4.00 24,000 2 82 10.00
13.00 15.50 74 [566
] [10.8] [7.0]
RCFL-H*3621A*(RGPR-10?BRM?) 31,111 27,650 8,950 1,225 37,200 24,200
[10.7] [8.1] [2.6] 12.00 15.00 74 [578] [10.9] 3.96 4,2[7.1] 2.78 10,00
036JEZ RHKL HM3617(RCSL H*3617A") [1�8] 2[88 j0 [2 6] 13.00 15.50 74 1,28) [10 9] [71
5 37,200 3 98 24,200 2.80 10.00
]
RHSL HM3617(RCSL H*3617A*) 35,400 25,850 9,550 1[1041 [7.61 [2.8] 12.00 14.50 74 1,100 37,600 24,600
3.82 2.70 9.00
[519] [11.01
35,400 25,850 9,550 [7 21
RHSL-HM3621 (RCSL-H*3621A*) [10.4] [7.6] (2,81 12.00 14.50 74 1.100 37,600 24,600
[519] [11.0] 3.82 2.70 9.00
40.000 30,000 10,000 [7.2]
RHLL HM4821 (RCSL H'4621A*)01, [11.71 [8.8] [2.9] 12.50 15.50 74 [661] 39,500 3.98 25,600 2.70 9.50
[661] (11.6] [7.5]
RCFL-H*4821A* 39.500 29,500 10,0u0 1,400 40,500 26,400
[i 1.6] [8.6] [2.9] 11.50 14.00 74 [6611 (11.91 3.76 [7 71 2.56 9.00
RCFL H'4821A'(RGLR 07?BRQ?) [1156] 2[8 7] 9,950
2 9] 12.00 14.50 74 1,425 40,000 3 90 26,000 2.66 9.50
[672] [11.7] [7.6]
RCFL H*4821A*(RGLR 10?BRM?) [1,T] 3[8 8]0 I2 9] 12.00 14.50 74 1,375 39.500 3.94 25,800 2.6G 9.50
[649) [11.61 [7.6]
RCFL-H*4821A'(RGPR-07?BRQ?) 40,000 3[88] [2 9] 12.00 14.50 74 1,400 39,500 25,800
(661] [11.6] 3.92 [7.6] 2.66 9.50
RCFL-H*4821A'(RGPR-10?BRM?) [9156] 2[8�] [29] 12.00 14.50 74 1,425 [11.71 3 88 26,000 54 9.50
[672] [11.71 [7.6]
RCFL-H*4824A* 39,500 29,500 10,000 1,400 40,500 26,400
[11.6] [8.6] [2.9) 11.50 14.00 74 [661] [11.9] 3.76 2.56 9.50
0.000 30.350 9,650 [7.7]
4 RCFL-H*4824A*(RGGD-12?RCM?) 12.00 14.50 74 1,450 40,000 26,000[11.71 (8.9) [2.81 [684] [11.71 3.88 [7.61 2.64 9.50
042JEZ RCFL H*4824A*(RGJD 12?RCM?) [01 0� 3[8 9j0 l2$] 1,450 40,000 3 88 26,000 2.64 9.50
12.00 14.50 74 [684] [11.1]
39,500 29,550 9,950 [7.61
RCFL H*4824A*(RGLR 07?BRQ?) [11.6] [8.7] [2 g] 12.00 14.50 74 1,425 40,000 390 26,000 2.66 9.50
[672] [11.7] [7.6]
RCFL-H*4824A*(RGLR-10?BRM?) 0,00] 30,050 9,950 12.00 14.50 74 1,375 39,500 3 94 25,800 2,66 9.50
[649] [11.6] 5,80
RCFL H*4824A*(RGLR 12?ARM?) 40,0001 3[8 8j0 9,950 12.00 14.50 74 1,425 39,500 3 92 25,800
[672] [11.61 [7.6] 2.66 9.50
RCFL H*4824A*(RGPR 07?BRQ?) [11,71 3[8 8j0 [2 91 12.00 14.50 74 1,400 39,500 3 92 25,800 2.66 9.50
[6611 [11.6] (7.6)
RCFL H*4824A*(RGPR 10?BRM?) [9156] 2[861 [2 9] 12.00 14.50 74 1,425 40,000 3.88 26,000 2.64 9.50
[672] [11.71 [7.6]
RCFL-H*4824A*(RGPR-12?ARM?) 0, 0) 30,050
9,950
2 9] 12.00 14.50 74 1,400 39,500 3 92 25.800 2.66 9.50
[6611 [11.6] 178'
RHKL-HM4821 (RCSL-H'4821A') 0, 0] 30,000
10,000 12.50 15.00 74 1,400 39,500 25,.61
[661] [11.6] 3.98 2.68 9.50
39, 28,900 10,100 [7.5]
RHSL-HM4221 (RCSL H*4821A*) 000 111.41 [8.5) [3.0) 11.50 13.50 74 [631.371 4Q500 3.74 26,400 256 9.00
17.71
RHLL HM4821 (RCSL H*4821A')O [1331 [1021 750 1[31] 13.00 15.00 74 1_600 45,500 382 29,200 2.50 1755] [13.31 [8.6] 9.00
RCFL-H*4821A* 44,000 33,250 10,750 1,475 46,000 29,800[12.9] [9.7] [3.1] 11.50 14.00 74 3.68 2.42 9.00
(
RCFL-W4821A' RGLR-07?BP,Q? 46,000 36,300 9,700 [696] [13.5] [g,71
048JEZ ) [13.5] [10.61 [2.8] 12.00 14.50 74 1,625 46,000 3.70 29,800 2.44 9.00
[767] [13.5] [8.7]
RCFL-H*4821A'(RGLR-10?BRM?) [6,00 35,950 10,050 1,575 46,000 29, ]6D0
[8.7
] [10.5] [2.9] 12.00 14.50 74 [7431 [13.5] 3.72 2.44 9.00
RCFL-W4821A*(RGPR-07?BRQ?) 46,000 36,300 9,700
[13.5] [10 6' 12.00 14.50 74 1,625 46,000 29 600
[2.0"1 [767] 113.51 3.72 [8.71, 2.44 9.00
RCFL-H*4824A* 44,000 33,250 10,750 1475 46,000 2
[12.91 [9.71 [3.1 11,50 14.00 74 ] 3.68 [87 2,42 9.00
i0 Highest sales volume tested c J [696]
9 combination required by DOE test procedures.
[ ]Designates Metric Conversions
Rheem Heating,Cooling and Water Heating 7
I \
Performance Data ARI Stan.rd Conditions-RPOL-JEZ
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Model Numbers ARI cooling Performance ARI Healln Performance 70°F(21'Cl Indoor
80°F[26.5°Cl DB/67°F 119.5°Cl WB Indoor Air
95°F[35°C]DB Outdoor Air Outdoor Air Outdoor Air
Outdoor 47°F[8.5°C]DB/
Indoor Total 17°F(-8.5'Cl DB/ DOE
Net 43°F WB 15°F[-9.5'Cl WB Re Ion
Unit Coil and/or Capacity Sens.
s. Latent Sad. Indoor DOE High(yh Tamp. DOE Low Temp• IV
RPOL- Air Handler BTU/H BTU/H RTU/H EER SEER Rate CFM QTU/H STU/N HSI'F
/1 [kWl lkW] [kWl d9 [Us1 IkW1 COP COP
11/14;08 RCFL-H'4824A'(RGLR-07?BRQ? 46,000 36,300 9,700 IkWI
[13.5] [10.61 [2.8] 12.00 14.50 74 [7675 46,000 3.70 29,800
RCFL-HW4824A'(RGLR-10?BRM?) 46 000 35,95] 1[02 9] 1,575 46,000 29,600
11 A [16.5 12.00 14.50 74 [743 3.72 ] 2.44 9.00
1 [13.5] [8.7
RCFL H'4824A'(RGLR 12?ARM?) [63 5] [000 60 6] [2 9] 1,600 46,000 29,600
12.00 14.50 74 [755j [i3.5] 3.74 [8•7] 2.44 9.00
RCFL-H'4824A'(RGPR-07?BRQ?) 46,000 36,300 9,700 17551 [13.5] 2[8.7]
[13.51 [10.6] [2•8] 12.00 14.50 74 3.72 2.44 9.00
[7671 [13.5] [8.7]
048JEZ RCFL-W4824A'(RGPR-12?ARM?) 46,000[13.5, 310.5]950 10,05
12.00 14.50 74 1,575 46,000 3 72 29,600
[7431 [13.5] [8,7] 2.44 9.00
RHKL HM4821 (RCSL H'4821A') [6,000 35900 100
3 5] [10.51 1[3 01 13.00 15.00 74 1,575 45,500 3 78 29,400 2 48 9.00
[743] [13.3] [8.6]
RHSL-HM4821 (RCSL-H'4821A') 43 3] [1500 0 31 150 10350
1720 46,500 3 66 30,000 2.40 9.00
11.50 14.00 74 1 ) [13.6] [8,8
RHKL-HM4824(RCSL-H'4824A") [6,60 36,650 9,850 1.625 45,500 29,200] [10.7] [2.9] 13.00 15.00 74 [767] 113.3J 3.84 [8.6 2.52 9.00
RHLL HM4824(RCSL-H"4824A') 46,500 36.650 9,850 ]
[13.6] [10.7] (2_9[ 13.00 15.00 74 [767] [1625 3 31 3.84 500 2[86] 2.52 9.00
RHSL HM4824(RCSL H"4824A') [ 35,150 53 3j [10.3J 1(3 OJ 1,525 46,500 3.66 30,000 2.40 9.00
11.50 14.00 74 (720
1 (13.6j [8.8)
RHLL HM6024(RCSL H'6024A')0 [9�41 4225 1 1[5�� 12.50 14.50 74 1,800 60,500 3 86 37,800 2 70 9.50
[849] [17.7] (11.1]
RCFL-H'6024A' 57,000 39,750 17,250 1,675 61,000 37,800
060JEZ [16.7] [11.61 [5.1] 11.50 13.50 74 3.32 3.70 9.50
[790] [17.9] f11.1]
RHKL HM6024(RCSL H'6024A') 617 71 [13 001 1[��J 1,800 60,500 3.90 37,600 2.74 9.50
12.50 14.50 74
(849] [17.71 [11.0]
RHSL-HM6024(RCSL-H'6024A') 58,500 42,200 16,300 [ 491 617.71 [1 .0]
[17.1] [12,4] (4,8] 11.00 13.00 74 ] 3.66 [11.4 2.58 9.50
O Highest sales volume tested combination required by DOE test procedures. [8�] [18 0 ]
[ ]Designates Metric Conversions
8 Rheem Heating, Cooling and Water Heating
�.
I
..
I�
,.,, �
1
I
Electrical and Physical Jata: RPQL- JEZ
ELECTRICAL
Model Compressor PHYSICAL
Number Phase , Fan Motor Minimum Fuse or HACK Retri
RPQL_ Frequency(Hz) Rated Load Locked Rotor Full Load Circuit Circuit Breaker Outdoor Coil g Weight
Voltage Volts Amperes Amperes Amperes Am acit Per
g ( ) p p p Y Minimum Maximum Face Area NO. Circuit
IRS+) (LRA) (FLA) Amperes Amperes AmperesNet Rev.11/10/2008 Sq.Ft.[m2] Rows CFM[L/s] Oz.[g] Lbipping
018JEZ 1-60-208/230 9/9 48 0.8 18/18 15/15 20/20 11.0[1.02] 1 1925 [908] 5[2410] 156 [70.8j 166 [75.31
024JEZ 1 60 208/230 13.5/13.5 58.3 8
0.8 18/18 25/25 30/30 1 13.0[1.21 1 1 1 finor [908] 98(2778J 156 [70.8] 167 [75.8)
030JEZ 1-60-208/230 14.1/14.1 73 0.8 19/19 25/25 30/30 17.1[1.59] 1 1925 [9osJ 120[3402j 175 [79.4j 186 (75[84.4)
036JEZ 1-60-208/230 17.5/17.5 79 0.8 23/23 30/30 40/40 33.6[3.12] 1 3575[1687] 194[55001 246[111.6] 256[116.1j
042JEZ 1-60-2W/230 17.9/17.9 112 0.8 24/24 30/30 40/40 33.6[3.12] 2 3575[16871 208[5897J 256[116.11 266[120.71
0JEZ 1-60-208/230 19.9/19.9 109 0.8 26/26 35/35 45/45 44.0[4.09j 2 3575[iG87J 231[6549J 258[117.0] 268(121.6)
06060JEZ 1-60-208/230 26.4/26.4 134 2.8 36/36 45/45 60/60 44.0[4.09j 2 3100[1463J 277[7853J 308[139.7] 318[144.2]
Unit Dimensions
T TAGE
mm)
ji
AIR DISCHARGE ALLOW Rr[1524 mm]CLEARANCEW HIGH VOLTAGE
111/32"[34 mm]
LIQUID LINE
CONNECTION
H SERVICE ACCESS
ACCESS TO ELECTRICAL&
PANEL ACC [73 mm]DIA. VALVES ALLOW
ACCESSORY KNOCKOUTS24"[610 mm]
\ HIGH PRESSURE CLEARANCE
CONTROL ONE SIDE
MANUAL RESET
o (FIELD INSTALLED
ACCESSORY)
AIR INLETS
(LOUVERS) ALLOW 24"[610 mm]
ALLOW 6"1152 min] ACCESS CLEARANCE
MIN.CLEARANCE
3 SIDES
67odel Numher Height"H" Length"L" 9",
Nn"
RPQL (Inches)[mm] (Inches)[mm]
018JEZ 19[482] 40V2[1028] e ]
024JEZ 19[482] 443/B[1127]
030JE77�Z/036JEZ/042JEZ 25[635] 1443/3 11127] 31,/2[800]
048JEZ/060JEZ 33[838] 443/a[1127] 311/2[800]
[ ]Designates Metric Conversions
Rheem Heating,Cooling and Water Heating 9
i
Heat Pump Refrigerant Lip,a Size Information
Line Size Liquid Line Sizing(R-410A)
System Connection Line Size Outdoor Unit Above or Below Indoor Coil(Heat Pumps Only
Capacity Size (Inch O.D.) Total Equivalent Length-Feet[m]
(Inch I.D.) [mm] 25[7.62] 50[15.24]
[mm] 75[22.861 100[30.48] 1 125[38.10] 150[45.721
Maximum Vertical Separatlon-Feel(ml
1/4 [6.35) 25[7.621 40[12.191 25 [7.62) 9 12.741 N/A N/A
1V2Ton .5 5/16 [7.94] 25 762 50 15.24 62 18.901 58[17.68) 53[16.15J 49[14.94]
[9.53] [ ] [ ] [
3/8* 19.531 25[7.621 50[15.241 75[22.861 72[21.951 70[21.341 68[20.731
114 [6.351 23[73/8' .011 N/A N/A N/A N/A N/A
[9.53]
2 Ton 5/16 [7.941 25[7.621 36[10.971 29 [8.84] 23 [7.01) 16 [4.88] 9 12.741
3/8* [9.53j 25[7.621 50[15.24] 72[21.951 70[21.34] 68[20.73] 65[19.811
1/4 [6.351 25[7.621 N/A N/A N/A N/A N/A
21/2 Ton [9/31 5/16 [7.941 25[7.621 0(14.94) 38[11. 881 27 [8.231 17 [5.181 6 [1.831
3/8* [9.531 25[7.621 50[15.24) 68[20.731 65[19.81j 62[18.90] 58[17.68)
3 Ton 3/8' 5/16 [7.94] 25[7.621 50[15.241 37[11.28] 22 [6.71] 7 [2.13] N/A
[9.53] 3/8* [9.53] 25[7.62] 50[15.24) 68120.73] 63[19.201 58[17.68] 53[16.15]
31/2 Ton 3/8' 5/16 [7.94] 25[7.62] 23 [7.01] 4 11.221 N/A N/A N/A
[9.531 3/8* [9.53] 3[7.62] 50[15.24] 43(13.11] 36110.97] 30 19.14] 24 [7.32]
4 Ton 3/8" 3/8* [9.531 25[7.62] 46[14.02] 38[11.58] 30 [9.141 22 [6. 111 15 [4.571
-F 19.531 1/2 [12.71 25[7.62] 50[15.241 56[17.071 55[16.76) 53 116.15] 52[15.85]
5 Ton NOTES: 3/8' 3/8* [9.53] 25 17.62] 50[15.24] 56(17,07] 44(13.41] 32 [9.75] 20 [6.10]
[9.53] 112 [12.71 25(7.62] 50[15.241 75[22.86) 81 [24.691 79(24.08) 76[23.161
*Standard line size
N/A=Application not recommended.
Suction Line Length/Size versus Capacity Multiplier(R-410A)
Unit Size 11/2 Ton 2 Ton 21/2 Ton 3 Ton 31/2 Ton 4 Ton 5 Ton
Suction Line
Connection Size 3/4"(19.05]I.D. 7/8"[22.231 I.D.
Suction Line[ Run- 3/e"[15.88 mm]O.D.Opt. 3/4'[119.05 mm]]OR O.D.Sttdt* 3/4"(19.05 mm]O.D.Opt. z/8"[22.23 mm]O.D.Opt.
[ ] /4"[19.05 mm]O.D.Std.* 7/8"[22.23 mm]O.D.Opt. 718"[22.23 mm]O.D.Std.* 1Ve"[28.58 mm]O.D.Std.*
Optional 1.00 1.00 1.00 1.00 1.00 1.00 1.00
25' [7.62] Standard 1.00 1.00 1.00 1.00 1.00 1.00 1.00
Optional - - 1.00 - -
Optional 0.98 0.98 0.96 0.98 0.99 0.99 0.99
50'[15.24] Standard 0.99 0.99 0.98 0.99 0.99 0.99 0.99
Optional - - 0.99 - -
Optional 0.95 0.95 0.94 0.96 0.96 0,96 0,97
100'[30.481 Standard 0.96 0,96 0.96 0.97 0.98 0,98 0.gg
Optional - - 0.97 - - _
Optional 0.92 0.92 0.91 0.94 0.94 0.95 0.94
150'[45.72] Standard 0.93 0.94 0.93 0.95 0.96 0.95 0.97
Optional - - 0.95 - -
NOTES:
*Standard line c17a
Note:Using suction line larger than shown in chart will result in poor oil return and is not recommended.
[ ]Designates Metric Conversions
10 Rheem Heating, Cooling and Water Heating
NOTES
Rheem Heating,Cooling and Water Heating 11
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY
INFORMATION AVAILABLE FROM YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product RPQL-JEZ Conditional Replacement Warranty:
which fails in normal use and service within the applicable Rheem will provide a replacement model(if an exact
period stated, in accordance with the terms of the limited replacement is not available,an equivalent product will be
warranty provided)to the original purchaser if the compressor fails
For Complete Details of the Limited Warranty,Including Applicable Terms within 5 years(providing the unit is installed with a new
and Conditions,see Your Local Installer or Contact the Manufacturer for Rheem Air Handler OR Rheem Indoor Coil with a Rheem
a Copy. Gas Furnace, and is properly matched as specified by
Rheem as listed in the Air Conditioning Institute(ARI)pub-
Compressor......................................................Ten (10)Years lished rating,and if additional conditions are satisfied.See
Any Other Part ..........................................Ten (10)Years product warranty card for additional information.
Before proceeding with installation,refer Rheem Heating,
to installation instructions packaged Cooling and '
with each model,as well as complying t
with all Federal,state,Provincial,and :"later Heating
Local codes,regulations,and practices. P.O.Box 17010,Fort Smith,AR 72917
"In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice."
PRINTED IN U.S.A. 4-09 DC FORM NO.P11-780 REV.1
Supersedes Form No.P71-700
CITY OF ARLINGTON
BUILDING DEPARTMENT
APPROVED
DATE COPY
N cF nr�c�s AUTHORED OFFICE
UNLESS APPROVED BY TH
BUILDING INSPECTO