HomeMy WebLinkAbout19923 48th Dr Ne_BLD5622_2026 RESIDENTIAL MECHANICAL APPLICATION
Community and Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 - Phone(360) 403-3551
This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Gas Piping
Property Address: 19923 48th Dr Ne Arlington 98223 project Valuation: $5973
Lot#: Parcel ID No.: 00849100003300 Preferred Contact: O Owner 71 Contractor
Project Description: Replace gas furnace
Lindsay Torralba 425-322-9920
Owner Name: Y Home No.:
Email Address: greenrae27@yahoo.com Cell No.:
Mailing Address: Same as Site City: State: Zip:
Contractor Name: Brennan Heating Office No.: 206-248-7900
Email Address: jaimie@brennanheating.com Cell No.:
Mailing Address: 4601 S 134th PI City: Tukwila State: Wa Zip:98168
L&I Contractor License Number: BRENNHA971 R9 Expiration Date: 12/29/23
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Gas Piping Information O Not Applicable
❑CSST ❑ Brass ❑ Other
Proposed Piping Material:
❑ Black Steel ❑ Galvanized Steel
Proposed Piping Size: ❑ y2" ❑ 5/s" 3 3/4" ❑ 1" ❑ 1Y2" O 2"
Distance from Meter to furthest Appliance: Total BTU's of all Appliances:
MECHANICAL PERMIT FEES(per unit)
Type of Fixture No.of Units Cost per Unit Subtotal Model No.
Additional Plan Review fees x $75.00 =
Air Cond.Unit s100Btu h x $ 15.00 =
Air Cond.Unit>10013tu h x $25.00 -
Air Cond.Unit>50013tu h x $50.00 =
Air Handling Units x $15.00 =
Base Mechanical Fee 1 x $25.00 - $ 25.00
Boiler<10013tu h>3h x $ 15.00 =
Boiler>1 million Btu/h<50hp x $25.00 =
REV03.2022 Page 1 of 2
MECHANICAL PERMff FEES(per unit)
Boiler>1.5 million Btu h<50h x $50.00 =
Boiler>100Btu h 3-15h x $ 15.00 =
Boiler>500Btu h 15-30hp x $25.00 =
Commercial Hoods-Type I x $25.00 =
Commercial Hoods-Type 11 x $50.00 =
Diffusers x $ 15.00 =
Dryer Ducting x $15.00 -
Ductwork(drawings required) x $25.00 =
Evaporative Coolers x $ 15.00 =
Exhaust Ventilation Fans x $ 15.00 =
Fire lace Insert Stove x $15.00 -
Forced Air Heat 5100 Btu h ' x $15.00 -
Forced Air Heat>100 Btu h x $25.00 =
Gas Clothes Dryer x $ 15.00 -
Gas Fired AC :5100 Btu h x $ 15.00 =
Gas Fired AC>100 Btu h x $25.00 =
Gas Fired AC>500 Btu h x $50.00 =
Gas Pi in <- 5 units x $ 15.00 =
Gas Piping>5 units(plus<5 units x $2.00 =
Heat Exchangers x $15.00 -
Heat Pump-Condensing Unit x $25.00 =
Hot Water Heat Coils x $ 15.00 =
Miscellaneous Appliance-regulated by x $15.00 =
mechanical code,not otherwise specified
Pkg.Units:5100btu x $25.00 =
Pkg.Units>100btu x $50.00 =
Range/Cook to -Gas Fired x $15.00 Refrigeration Unit<-100Btu h x $15.00 =
Refrigeration Unit>100Btu h x $25.00 =
Refrigeration.Unit>SOOBtu h x $50.00 =
Re-inspection fee x $75.00 =
Residential Range Hood x $ 15.00 =
Unit Heaters<- 100 Btu h x $ 15.00 -
Unit Heaters>100 Btu h x $25.00 =
VAV Boxes(Variable Air Volume,part of air x $ 10.00 =
conditioning system)
Wall Heaters-Gas Fired x $25.00 =
Water Heater-Gas Fired x $25.00 =
Permit Fee
Inspection Fee $75.00
Processing/Technology Fee $25.00
Total
REV2.2020 Page 2 of 2
PRESSURE PIPING SCHEMATIC
COMPLETE FOR GAS PIPING ONLY
SCHEMATIC IS TO SCALE F SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE;Any interior pressure regulators must be indicated
1 l 1 V,
I hereby certify that I am the ❑Owner, [Applicant [!(Contractor, and authorized to sign this application and that the above
information is correct and construction on, and the occupancy and the use of the above described property will be in accordance with
thq4rnys, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained
hen omplete.
Jaimie How 10/5/23
Si tore Print Name Date
SAVE PRINT
Page 3 of 3
REV2.2020
SPECIFICATIONS 4
Gas Model No. SL28ODF07OV36A SL28ODF09OV48B SL280DF09OV60C SL28ODF11OV60C
Heating 'AFUE 80% 80% 80% 80%
Performance High Input-Btuh 66,000 88,000 88,000 110,000
Fire Output-Btuh 52,000 69,000 70,000 87,000
Temperature rise range-°F 35-65 35-65 35-65 35-65
Gas Manifold Pressure(in.w.g.) 3.5/ 10.0 3.5/ 10.0 3.51 10.0 3.5/ 10.0
Nat. Gas/LPG/Propane
Low Input-Btuh 43,000 57,000 57,000 72,000
Fire Output-Btuh 35,000 46,000 F 46,000 59,000
Temperature rise range-°F 25-55 25-55 25-55 25-55
Gas Manifold Pressure(in.w.g.) 1.714.5 1.7/4.5 1.7/4.5 1.7/4.5
Nat. Gas/LPG/Propane
High static-in.w.g. Heating 0.8 0.8 0.8 0.8
Cooling 1.0 1.0 1.0 1.0
Connections Flue connection-in. round 4 4 4 4
in. Gas pipe size IPS 1/2 112 1/2 1/2
Indoor Wheel nominal diameter x width-in. 10 x 8 11 x 9 11 x 10 11 x 10
Blower Motor output-hp 1/2 1 1 1
Tons of add-on cooling 2-3 3-4 3.5-5 3.5-5
Air Volume Range-cfm 589- 1514 830- 1996 899-2273 882-2120
Electrical Voltage 120 volts-60 hertz- 1 phase
Data Blower motor full load amps 7.7 12.8 12.8 12.8
Maximum overcurrent protection 15 20 20 20
Shipping Data lbs. - i package j 130 153 164 173
NOTE-Filters and provisions for mounting are not furnished and must be field provided.
'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces.
OPTIONAL ACCESSORIES - ORDER SEPARATELY
NOTE -FURNACES CANNOT BE TWINNED!
"A"Width "B"Width "C"Width
Models Models Models
CABINET ACCESSORIES
Downflow Combustible Flooring Base I 11M59 I 11M60 11M61
CONTROLS
S40 Smart Wi-FI Thermostat 22V24 22V24 22V24
2 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658
' Discharge Air Temperature Sensor 88K38 88K38 881<38
DOWNFLOW FILTER KITS
3 Downflow Filter Cabinet 51 W06 51 W07 51 W08
No. and Size of filter-in. (1)20 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1
Remote Outdoor Air Temperature Sensor is used with conventional(non-Lennox®Communicating)outdoor units(sensor is furnished with Lennox®Communicating
outdoor units).Allows the thermostat to display outdoor temperature.Required in dual-fuel and EDA applications.
s Optional for service diagnostics.
Cleanable polyurethane,frame-type filter.
ei 9onrimi/ci w o
CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center:360-403-3551
BUILDING PERMIT
19923 48TH DR NE Permit#:5622
Parcel#:00$491 b0003300 PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work: Replace gas furnace Valuation:5973.00
OWNER APPLICANT CONTRACTOR
TORRALBA LINDSAY R/HUMBERTO Brennan Heating Brennan Heating
S
19923 48TH DR NE 4601 S 134th PI 4601 S 134TH PL
ARLINGTON,WA 98223-6368 Tukwila Wa 98168 TUKWILA,WA 98168
2062487900 206-248-7900
LIC:602 346 866 EXP: 12/31/2023
LIC:BRENNHA971 R9 EXP: 12/29/2023
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR. 2018
STORIES: I CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC IOARCI 10.
SALES TAX NOTICE,• Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sale ax turn form and coded City of Arlington#3101.
O a3 �h— 10/05/2023
Applicant Signature Date Building Official Date
CONDITIONS
Adhere to approved mechanical equipment.Call for final inspection.Permit shall be onsite for inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
10/05/2023 Processing/Technology $25.00
10/05/2023 Inspection $75.00
10/05/2023 Mechanical Base $25.00
10/05/2023 Gas Piping/Units $15.00
10/0512023 Forced Air Heat 5 100 BTU/h $15.00
Total Due: $155.00
Total Payment: $155,00
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
INSPECTION INFORMATION IPass/Fail
Permit#: 5622
Permit Date: 10/05/23
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Torralba
Applicant Name: Brennan Heating
Applicant Address: 4601 S 134th PI
Applicant, City, State, Zip: Tukwila Wa 98168
Contact: Brennan Heating
Phone: 2062487900
Email:jaimie@brennanheating.com
Scope of Work: Replace gas furnace
Valuation: 5973.00
Square Feet: 1276
Number of Stories: 1
Construction Type:
Occupancy Group:
ID Code:
Permit Issued:
Permit Expires:
Form Permit Type: RESIDENTIAL MECHANICAL
Status: ISSUED
Assigned To: Hannah Hardwick
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
TORRALBA 100 SINGLE
00849100003300 19923 48TH DR NE LINDSAY FAMILY
RMUMBERTO S RESIDENCE
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866
CONTRACTOR
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9
CONTRACTOR Industries
Fees
Fee Description Notes Amount
Processing/Technology $25.00
Inspection $75.00
Mechanical Base Permit Fee $25.00
Gas Piping/Units Enter#of units $15.00
Forced Air Heat<100 BTU/h Enter#of units $15.00
Credit Card Service $4.65
Total $159.65
Attached Letters
Date Letter Description
10/05/2023 Building Permit
10/05/2023 Web Form-Residential Mechanical Application
Payments
Date Paid By Description Payment Type Accepted By Amount
10/05/2023 XBP Con£ $155.00
155521247
10/05/2023 Brennan Heating 155521247 Hannah Hardwick $4.65
Outstanding Balance $0.00
Notes
Date Note Created By:
10/05/2023 Sent permit to contractor for signature Hannah Hardwick
Uploaded Files
Date File Name
10/05/2023 17103025-BLD5622 Signgd.pdf
10/05/2023 06b2e757e8b8ea6d554f1eb94fc17898 torralbaspecs.pdf
10/05/2023 79575a6ac589c29de65cbb4d5961bcb8 torralbamechapp.pdf