HomeMy WebLinkAbout19923 48th Dr Ne_BLD5622_2026 RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 - Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Gas Piping Property Address: 19923 48th Dr Ne Arlington 98223 project Valuation: $5973 Lot#: Parcel ID No.: 00849100003300 Preferred Contact: O Owner 71 Contractor Project Description: Replace gas furnace Lindsay Torralba 425-322-9920 Owner Name: Y Home No.: Email Address: greenrae27@yahoo.com Cell No.: Mailing Address: Same as Site City: State: Zip: Contractor Name: Brennan Heating Office No.: 206-248-7900 Email Address: jaimie@brennanheating.com Cell No.: Mailing Address: 4601 S 134th PI City: Tukwila State: Wa Zip:98168 L&I Contractor License Number: BRENNHA971 R9 Expiration Date: 12/29/23 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ y2" ❑ 5/s" 3 3/4" ❑ 1" ❑ 1Y2" O 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: MECHANICAL PERMIT FEES(per unit) Type of Fixture No.of Units Cost per Unit Subtotal Model No. Additional Plan Review fees x $75.00 = Air Cond.Unit s100Btu h x $ 15.00 = Air Cond.Unit>10013tu h x $25.00 - Air Cond.Unit>50013tu h x $50.00 = Air Handling Units x $15.00 = Base Mechanical Fee 1 x $25.00 - $ 25.00 Boiler<10013tu h>3h x $ 15.00 = Boiler>1 million Btu/h<50hp x $25.00 = REV03.2022 Page 1 of 2 MECHANICAL PERMff FEES(per unit) Boiler>1.5 million Btu h<50h x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type 11 x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $15.00 - Ductwork(drawings required) x $25.00 = Evaporative Coolers x $ 15.00 = Exhaust Ventilation Fans x $ 15.00 = Fire lace Insert Stove x $15.00 - Forced Air Heat 5100 Btu h ' x $15.00 - Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 - Gas Fired AC :5100 Btu h x $ 15.00 = Gas Fired AC>100 Btu h x $25.00 = Gas Fired AC>500 Btu h x $50.00 = Gas Pi in <- 5 units x $ 15.00 = Gas Piping>5 units(plus<5 units x $2.00 = Heat Exchangers x $15.00 - Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $15.00 = mechanical code,not otherwise specified Pkg.Units:5100btu x $25.00 = Pkg.Units>100btu x $50.00 = Range/Cook to -Gas Fired x $15.00 Refrigeration Unit<-100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>SOOBtu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<- 100 Btu h x $ 15.00 - Unit Heaters>100 Btu h x $25.00 = VAV Boxes(Variable Air Volume,part of air x $ 10.00 = conditioning system) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total REV2.2020 Page 2 of 2 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY SCHEMATIC IS TO SCALE F SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE;Any interior pressure regulators must be indicated 1 l 1 V, I hereby certify that I am the ❑Owner, [Applicant [!(Contractor, and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above described property will be in accordance with thq4rnys, rules and regulation of the State of Washington, and the City of Arlington.A final inspection and approval shall be obtained hen omplete. Jaimie How 10/5/23 Si tore Print Name Date SAVE PRINT Page 3 of 3 REV2.2020 SPECIFICATIONS 4 Gas Model No. SL28ODF07OV36A SL28ODF09OV48B SL280DF09OV60C SL28ODF11OV60C Heating 'AFUE 80% 80% 80% 80% Performance High Input-Btuh 66,000 88,000 88,000 110,000 Fire Output-Btuh 52,000 69,000 70,000 87,000 Temperature rise range-°F 35-65 35-65 35-65 35-65 Gas Manifold Pressure(in.w.g.) 3.5/ 10.0 3.5/ 10.0 3.51 10.0 3.5/ 10.0 Nat. Gas/LPG/Propane Low Input-Btuh 43,000 57,000 57,000 72,000 Fire Output-Btuh 35,000 46,000 F 46,000 59,000 Temperature rise range-°F 25-55 25-55 25-55 25-55 Gas Manifold Pressure(in.w.g.) 1.714.5 1.7/4.5 1.7/4.5 1.7/4.5 Nat. Gas/LPG/Propane High static-in.w.g. Heating 0.8 0.8 0.8 0.8 Cooling 1.0 1.0 1.0 1.0 Connections Flue connection-in. round 4 4 4 4 in. Gas pipe size IPS 1/2 112 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 11 x 9 11 x 10 11 x 10 Blower Motor output-hp 1/2 1 1 1 Tons of add-on cooling 2-3 3-4 3.5-5 3.5-5 Air Volume Range-cfm 589- 1514 830- 1996 899-2273 882-2120 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 7.7 12.8 12.8 12.8 Maximum overcurrent protection 15 20 20 20 Shipping Data lbs. - i package j 130 153 164 173 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE -FURNACES CANNOT BE TWINNED! "A"Width "B"Width "C"Width Models Models Models CABINET ACCESSORIES Downflow Combustible Flooring Base I 11M59 I 11M60 11M61 CONTROLS S40 Smart Wi-FI Thermostat 22V24 22V24 22V24 2 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 ' Discharge Air Temperature Sensor 88K38 88K38 881<38 DOWNFLOW FILTER KITS 3 Downflow Filter Cabinet 51 W06 51 W07 51 W08 No. and Size of filter-in. (1)20 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 Remote Outdoor Air Temperature Sensor is used with conventional(non-Lennox®Communicating)outdoor units(sensor is furnished with Lennox®Communicating outdoor units).Allows the thermostat to display outdoor temperature.Required in dual-fuel and EDA applications. s Optional for service diagnostics. Cleanable polyurethane,frame-type filter. ei 9onrimi/ci w o CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 19923 48TH DR NE Permit#:5622 Parcel#:00$491 b0003300 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work: Replace gas furnace Valuation:5973.00 OWNER APPLICANT CONTRACTOR TORRALBA LINDSAY R/HUMBERTO Brennan Heating Brennan Heating S 19923 48TH DR NE 4601 S 134th PI 4601 S 134TH PL ARLINGTON,WA 98223-6368 Tukwila Wa 98168 TUKWILA,WA 98168 2062487900 206-248-7900 LIC:602 346 866 EXP: 12/31/2023 LIC:BRENNHA971 R9 EXP: 12/29/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR. 2018 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC IOARCI 10. SALES TAX NOTICE,• Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sale ax turn form and coded City of Arlington#3101. O a3 �h— 10/05/2023 Applicant Signature Date Building Official Date CONDITIONS Adhere to approved mechanical equipment.Call for final inspection.Permit shall be onsite for inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/05/2023 Processing/Technology $25.00 10/05/2023 Inspection $75.00 10/05/2023 Mechanical Base $25.00 10/05/2023 Gas Piping/Units $15.00 10/0512023 Forced Air Heat 5 100 BTU/h $15.00 Total Due: $155.00 Total Payment: $155,00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION IPass/Fail Permit#: 5622 Permit Date: 10/05/23 Permit Type: RESIDENTIAL MECHANICAL Project Name: Torralba Applicant Name: Brennan Heating Applicant Address: 4601 S 134th PI Applicant, City, State, Zip: Tukwila Wa 98168 Contact: Brennan Heating Phone: 2062487900 Email:jaimie@brennanheating.com Scope of Work: Replace gas furnace Valuation: 5973.00 Square Feet: 1276 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: RESIDENTIAL MECHANICAL Status: ISSUED Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning TORRALBA 100 SINGLE 00849100003300 19923 48TH DR NE LINDSAY FAMILY RMUMBERTO S RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9 CONTRACTOR Industries Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Mechanical Base Permit Fee $25.00 Gas Piping/Units Enter#of units $15.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Credit Card Service $4.65 Total $159.65 Attached Letters Date Letter Description 10/05/2023 Building Permit 10/05/2023 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 10/05/2023 XBP Con£ $155.00 155521247 10/05/2023 Brennan Heating 155521247 Hannah Hardwick $4.65 Outstanding Balance $0.00 Notes Date Note Created By: 10/05/2023 Sent permit to contractor for signature Hannah Hardwick Uploaded Files Date File Name 10/05/2023 17103025-BLD5622 Signgd.pdf 10/05/2023 06b2e757e8b8ea6d554f1eb94fc17898 torralbaspecs.pdf 10/05/2023 79575a6ac589c29de65cbb4d5961bcb8 torralbamechapp.pdf