Loading...
HomeMy WebLinkAbout17601 59th Ave Ne_BLD5628_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17601 59TH AVE NE Permit#: 5628 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052200405500 DATE OF ISSUANCE. Scope of Work: Provide fire alarm life safety Valuation:4140.75 OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Melinda Noordman/Absco ABSCO Solutions Inc PO BOX 1107 3400 188th St SW 19023 36thAve STE E EVERETT,WA 98206 lynnwood Lynnwood,WA 98036 4257711166 LIC:600 260 973 EXP: 10/31/2024 LIC:ABSCOAI961B EXP:06/30/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2018 STORIES: 1 CONST.TYPE: 1113 DWELLING UNITS: OCC GROUP: S-1; Storage Mod Hazard BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. /6-1 � 11/28/2023 Ve' Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/28/2023 Processing/Technology $25.00 11/28/2023 Fire System Plan Review $95.92 11/28/2023 FACP/Transmitter-New $200.00 11/28/2023 Fire Alarm System Permit $350.00 11/28/2023 Credit Card Service $20.13 Total Due: $691.05 Total Payment: $691.05 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17601 59TH AVE NE Permit#: 5628 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 31052200405500 DATE OF ISSUANCE. Scope of Work: Provide fire alarm life safety Valuation:4140.75 OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Melinda Noordman/Absco ABSCO Solutions Inc PO BOX 1107 3400 188th St SW 19023 36thAve STE E EVERETT,WA 98206 lynnwood Lynnwood,WA 98036 4257711166 LIC:600 260 973 EXP: 10/31/2024 LIC:ABSCOAI961B EXP:06/30/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: FIRE ALARM CODE YEAR: 2018 STORIES: 1 CONST.TYPE: 1113 DWELLING UNITS: OCC GROUP: S-1; Storage Mod Hazard BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 11/28/2023 Ve' Applicant Signature Date Building Official Date CONDITIONS Approved job copy shall be onsite for inspections.Adhere to approved plans The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/28/2023 Processing/Technology $25.00 11/28/2023 Fire System Plan Review $95.92 11/28/2023 FACP/Transmitter-New $200.00 11/28/2023 Fire Alarm System Permit $350.00 11/28/2023 Credit Card Service $20.13 Total Due: $691.05 Total Payment: $691.05 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail i FIRE ALARM PERM fT APPLICATION • Corn m unity and Econom is Developm ant City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: 0 New Installation ❑ System Modification [] Phased Installation 17601 59th Ave NE $ 33,126 Property Address: Suite No.: Project Valuation: Lot#: P arcel ID No.: 31052200405500 Preferred Contact: 71 Ow rer 0 Applicant 71 Contractor Project Description: Provide,program and test fire alarm equipment as outlined in this proposal.Design,equipment,head-end term nation,program mng,dem cnstration with the owner and confidence testing with the AHJ. Ow rer Nam e Snohomish County Public Utility Dist. No. 1 Phone No.: 425-783-8770 Emil Address: c dsbehar@snopud.com ell No.: M ailing Address: c 2320 California St. EE ity yerett W tate: zip: 98206 Applicant Name: P M dinda NOordm an hone No.: 509-321-1190 Email Address: C M dinda.Noordm an@abscosolutions.com ell No.: 509-820-0790 M ailing Address: C 3400 188th St SW Ste 461 ity Lynnwood tate: WA Zip: 98037 Contractor Name: pAbsco Solutions hone No.: 425-771-1166 Em ail Address: C Julie.Aspnes@abscosolutions.com ell No.: M ailing Address: C 3400 188th St SW Ste 461 ity:Ayn nwood W tate: Zip: 98037 L&I Contractor License Number: ABSCO AI961 J3 6 xpiration Date: /30/2024 SUBM UTAL REQUIREM ENTS: Provide Inform ction on All Equipm ent to be Installed Prior to Installation Subm it electronic files of the follow: ® Complete and Scaled Plans ® Specification Sheets ® Wiring Diagram s(Point to Point Wiring) ® Electrical Plans,if applicable NOTE: All Central Station M onitoring in ust be UL or FM listed. FIRE ALARM SYSTEM S(105.7.3) ** DEVICES include separate individual portions of a Fire Alarm System such as: Initiating Devices, Notification Appliances, Flow Sw tch, Supervisory Sw tches, M agnetic Door Hold-Open Devices, Rem ate Annunciators, Pull Stations, Beam Detectors, and other such devices. (Each piece is one device) PLAN REVIEW FEES -shall be paid at tim eof application subm ttal Less than $5,000.00 = $100.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation per Fee Calculation Table 4-1) REV2022 Page 1 of 2 REINSPECTION / PHASED INSTALLATION INSPECTIONS Subm t Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour m inim tin) 75.00 TENANT IM PROVEM ENT OR SYSTEM M(DIFICATION (NFPA 72) Number of Devices" D evice Fee Subtotal 1 to 2 $ 75.00 = $ 3to5 $ 125.00 = $ 6 to 10 $ 175.00 = $ 11 to 20 $ 225.00 = $ 21 to 40 $ 300.00 = $ 41 to 100 $ 375.00 = $ 101 to 200 $ 475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(round up) Total Num ber of Devices = $ 500.00 + $ _ $ FACP/TRANSMITTER M edification $ 125.00 = $ PERM If FEE SUBTOTAL $ ✓Q NEW COM M IRCIAL SYSTEM (NFPA 72) Number of Devices" D evice Fee Subtotal 1 to 100 $ 350.00 = $350 101 to 200 $ 475.00 = $ > 200 $500.00 plus$50.00 per 100 additional devices(roundup) Total Num ber of Devices = 38 $ 500.00 + $ _ $ FACP/TRANSMITTER New $200.00 = $200 PERM Ir FEE SUBTOTAL $550 PERM If FEE TOTAL $550 PLAN REVIEW FEE $586.24 Processing/Technology Fee $25.00 TOTAL $1161.24 I hereby certify that 1 am the ❑ Owner, ❑✓ Applicant, ❑ Contractor,and authorized to sign this application and that the above inform ction is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. M dinda Noordm an 10/4/2023 Signature P rint Nam e D ate SAVE PRINT REV2022 Page 2 of 2 GENERAL NOTES FIRE LEGEND AND E UIPMENT LIST SHEET INDEX FA1.00 FIRE ALARM COVER SHEET TY SYMBOL MODEL NUMBER DESCRIPTION ROLLUDA ARCHITECTS,INC. 1. THE CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE BEFORE COMMENCING WORK AND REPORT ANY DISCREPANCIES TO FA2.01 FIRE ALARM PLAN 105 S MAIN ST,#323 AON FIRE PROTECTION ENGINEERING CORPORATION PRIOR TO CONSTRUCTION. FATC 7100 HONEYWELL GAMEWELL 7100 SERIES FIRE ALARM CONTROL PANEL SEATTLE,WA 98104 FHg4E 1206)6244222 FAX 2066244226 2. ALL MATERIALS AND WORK TO CONFORM TO ALL GOVERNING BUILDING CODES,REGULATIONS,ORDINANCES AND AGENCIES. 0 AS-24MCC CEILING MOUNTED MULTI-CANDELA STROBE FA3.01 FIRE ALARM DETAILS 0 AS-24MCW WALL MOUNTED MULTI-CANDELA STROBE 3. CONSTRUCTION SAFETY:ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF OSHA. 1 D® AH-24R MULTI-CANDELA HORN/STROBE 4. ALL COST FOR INSPECTIONS,TEST SERVICES,BUILDING PERMITS,LICENSES AND CERTIFICATES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 0 0 ASD-PLR ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS. B501 DETECTOR BASE 5. CONSTRUCTION TO COMPLY WITH THE REQUIREMENTS OF LOCAL GOVERNING AGENCIES OF THE COUNTY OF SNOHOMISH AND THE STATE OF WASHINGTON. O AAM-2RIF INTELLIGENT INITIATING INTERFACE MODULE INPUT W/RELAY 6. EXIT DOORS,EXIT SIGNS,FIRE ALARM MANUAL PULL STATIONS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY 0 s AOM-2RF ADDRESSABLE DUCT SMOKE DETECTOR coMATERIALS. JENSEN HUGHES ❑F AD-HR ADDRESSABLE MANUAL PULL STATION 707 WILSHIRE BLVD. 7. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE ON THE DRAWINGS. SUITE2600 ® MS-7 WATERFLOW SWITCH LOS ANGELES,CA 90017 8. THE ENTIRE WORK PROVIDED HEREIN IS TO BE CONSTRUCTED AND FINISHED EMPLOYING UALITY WORKMANSHIP AND IN ACCORDANCE WITH THE 1213.630.2020 DRAWINGS AND SPECIFICATIONS.ANY WORK RE UIRED BYLAW,BUT WHICH MAY NOT BE SPECIFICALLY MENTIONED HEREIN,SHALL BE DONE BY THE O N/A RISER VALVE SUPERVISORY SWITCH WWW.JENSENHUGHES.COM CONTRACTOR(S)IN ACCORDANCE WITH THE LAWS OF THE CITY,COUNTY,DISTRICT OR STATE UNDER WHICH JURISDICTION MAY COME AND COST SHALL JH PROJECT NO.:IKCT00173 BE BORN BY THE CONTRACTOR(S). ANY SUCH WORK SHALL BE DONE IN CONFORMANCE WITH THE PLANS BOTH AS TO THE MANNER AND APPEARANCE. LIANI ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF C.B.C.,TITLE 19,TITLE 24,AND AMERICANS WITH DISABILITIES ACT(ADA)AS p� 1 Wqs o RE UIRED BY THE GOVERNING AGENCIES. DEVICE MOUNTING HEIGHTS (PER NFPA 72, 2016 EDITION) 'o 9. THE OWNERS REPRESENTATIVE IS AUTHORIZED TO ORDER MINOR CHANGES DURING THE COURSE OF THE WORK WHICH WILL NOT INVOLVE EXTRA COST OR TIME WHICH ARE CONSISTENT WITH THE CONTRACT DOCUMENTS. 57218 4� AECISTE- 10. THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF APPROVED STAMPED DRAWINGS AT THE JOB SITE FOR USE IN MAKING"AS-BUILT DRAWINGS NO SUPPLY fss/ONALE ANY REVISIONS SHALL BE NOTED THEREON AND SUBMITTED TO THE OWNER S REPRESENTATIVE AT THE COMPLETION OF THE JOB PER THE OR RETURN DIFFUSER SPECIFICATIONS. CEILING MOUNTED NOTE'MEASUREMENTS SMOKEIHEAT 3(MIN) 4 SHOWN ARE TO THE 11. THE CONTRACTOR SHALL USE THE"AS-BUILT DRAWINGS"TO GENERATE A RECORD SET OF THE COMPLETED SYSTEM AND SUBMIT THE RECORD SET TO DETECTOR I s14 MIN) 02 ) CLOSEST EDGE OF THE THE PROJECT MANAGER. DETECTOR. AUDI12. ALL SMOKE DETECTION DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. O VISUAL-AL-ONLY DE DEVICES 4' SYNCHRONIZE IVJOOR (10 ) 12'(MAX1 13. PROVIDE VISUAL STROBE UNITS THAT MEET THE AMERICANS WITH DISABILITIES ACT AND REFERENCE A.D.A.FOR MOUNTING INSTRUCTION IN REGARDS AUDIOVISUAL MOREFIELD OF VIEW NAVY HEATDETECTOR MAX) TO PLACEMENT. • VISUAL-ONLY FIELD 013 EDITION DETECTOR DEVICES NFPA 722013 EDITIIX4 NHEEE R 14. JUNCTION BOX COVERS ARE TO BE RED FOR FIRE ALARM IDENTIFICATION WITH THE LETTERS"FA"APPEAR IN WHITE LETTERING. TO EXIT DOOR WALL MOUNTED 15. ALL FIRE ALARM E UIPMENT SHOWN ON DRAWINGS ARE NEW UNLESS INDICATED OTHERWISE. 5(MAX)(1524 HEAT DETECTOR , 16. THE FIRE ALARM AND LIFE SAFETY SYSTEM SHALL CONFORM TO ARTICLE 760 OF THE CALIFORNIA ELECTRIC CODE. ODOR APPLICABLE CODES wIOTH 17. INSTALLATION OF THE FIRE ALARM SYSTEM AND THE LIFE SAFETY SYSTEM SHALL NOT BE STARTED UNTIL DETAILED PLANS AND SPECIFICATIONS,INCLUDING STATE FIRE MARSHAL Ess3° 2018 INTERNATIONAL BUILDING CODE WITH WASHINGTON AND LISTING NUMBERS FOR EACH COMPONENT OF THE SYSTEM HAVE BEEN APPROVED BY THE COUNTY OF SNOHOMISH FIRE DEPARTMENT. 80"(ADA) (2032 ) J_ CITY OF ARLINGTON AMMENDMENTS 80'MIN196"MAX (2032 MINP2438 MAX) SIDEWALL 18. ALL DEVICES IN EXTERIOR SERVICE AREAS SHALL BE LISTED FOR OUTDOOR USE. NFPA722013EDITION 2018 INTERNATIONAL ELECTRICAL CODE WITH WASHINGTON AND Mp1,IJgL 0 I CITY OF ARLINGTON AMMENDMENTS 19. AUDIBLENISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE. PUL 6. STATION 52 I 2018 INTERNATIONAL FIRE CODE WITH WASHINGTON AND CITY OF 20. DETECTORS SHALL BE MOUNTED NO CLOSER THAN 3-O"OF ANY SUPPLY AIR REGISTER. MAGNETIC ARLINGTON AMMENDMENTS FTC DOOR 21. FIRE ALARM WIRING SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDED CONDUCTOR SIZES AND TYPE. ALL CONDUCTORS SHALL BE FIRE p I ® HOLDER 2016 STANDARD FOR THE INSTALLATION OF PERMANENTLY,AND UNI UELY IDENTIFIED. BONE-- «yyJJ SPRINKLER SYSTEMS(NFPA 13) JACK 48"MAX(ADA) (1219 ) 22. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWING SET. 42.MIw54"MAX(NFPA) (1067 AW372 MAXI 2016 NATIONAL FIRE PROTECTION ASSOCIATION z NEPA 72 2013 EDITION STANDARD72 WITH WASHINGTON AMENDMENTS p 3. ALL 120VAC CIRCUITS TO FIRE ALARM PANELS SHALL BE DEDICATED CIRCUITS. MgW 2 �_ FM Lu 24. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 25. ALL EXPOSED WIRING AND CABLE SHALL BE INSTALLED IN CONTINUOUS RACEWAYS,UNLESS OTHERWISE NOTED. FIRE ALARM SE U E N C E OF OPERATION 26. ALL CONDUIT TO BE 3/4"UNLESS OTHERWISE NOTED. 27. THE INSTALLING CONTRACTOR SHALL PROVIDE EMPLOYEES STATE CERTIFIED BYTHE DIVISION OF APPRENTICESHIP STANDARDS AS FIRE/LIFE SAFETY O z TECHNICIAN. 28. THE FIRE ALARM SYSTEM PLANS SHALL NOT BE MEANT TO CONVEYOR ALLOW DISCREPANCY BETWEEN THE WORK ILLUSTRATED HEREIN AND ALL I N I T I AT I O N FIRE ALARM SCOPE OF WORK APPLICABLE CODES,STANDARDS,AND ORDINANCES. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF OWNER AND ENGINEER. RESPONSE ALL NEW FIRE ALARM DEVICES ARE AUTOMATIC AND SHALL BE CONTROLLED FROM 29. FIRE ALARM CONTRACTOR RESPONSIBLE FOR FIELD VERIFICATION OF FIRE ALARM PANEL,FIELD TESTING,AND ANY DIAGNOSTIC WORK.FIRE ALARM THE NEW FIRE ALARM CONTROL PANEL AND ITS TRANSPONDERS. CONTRACTOR SHALL COORDINATE DIRECTLY WITH VARIOUS TRADES TO ENSURE INSTALLATION AND FUNCTIONALITY OF ALL SYSTEMS. ANNUNCIATE AT FIRE CONTROL ANNUNCIATE AT-< - -r rIF NEW FIRE ALARM SYSTEM IS AN AUTOMATIC FIRE ALARM SYSTEM SUPPLEMENTED BY MANUAL DEVICES. -TVATE LE re INSTALL NEW DEVICES ARE SHOWN ON FLOOR PLANS. W U. U. O a � zco O OD 07 W � 2 Z)L, < ccn > � C) Q= z Ui Lr3 C~7 Z O w co cn Z =-_ Q UOJFCT BUILDING IDENTIFIER. KEYPLAN C. 1 SHEET TITLE. FIRE ALARM COVER SHEET Cm I 1 I LEAD: KCT E�DI ----- DRAFTER AK DATE 03/22/22 SHEET - - - - - - - - - -------- FA1.00 SHEEP OF e ,I ...�x."��„-Always Vey v jai ROLLUDA ARCHITECTS,INC. 105 S MAIN ST,#323 SEATTLE,WA 98104 MME(206)624 m FAX(2WI624422fi A 4"CONCRETE PAD MECH UNIT,SEE IMECH DRAWINGS II FACP _ p JENSE H UGHES 707 WILSHIREBLVD. C FAo _F'2I SUUITEITE 26 2600 102 LOS ANGELES,CA 90017 D 00 SF N -1213,630.2020 - WWW.JENSENHUGHES.COM M _ JH PROJECT NO.:1KCT00173 M Llgp o�F -o-zBE�ow FF _ Pa �WAs�� N 6 w 218T NAIFIRE PLPRMFIBEIN-SE 2 2 2 z. -- p4 TRUE R ROOF PLAN N FLOOR PLAN N SCALE: 1/8,, 1-0" SCALE: 1/8" 1-0" O o F Q O z Lu fL U- co a � zp p N W CT� 2 � zU, < ccn p Y> C) �Qz O NOTES: _ LU Lo GENERAL NOTES: p I z 1. REFERENCE SHEET A6.01 FOR ROOM FINISH SCHEDULE. z p W 1. IDENTIFYING NUMBERS ADJACENT TO INITIATING DEVICE DENOTES ADDRESS,SUBSCRIPT ADJACENT TO INDICATING APPLICANCE DENOTES 2. REFERENCE SHEET A6.02 FOR DOOR SCHEDULE AND TYPES. CIO Q CANDELA RATING OR SE UENCE. 3. REFERENCE SHEET A7.01 FOR WALL TYPES. PRaw 2. ALL INSTALLATION MATERIAL SUCH AS CONDUIT,FITTINGS,BOXES,HANGERS,ETC.NOT SUPPLIED BY SIEMENS,FIRE SAFETY DIVISION,UNLESS BUILDING IDENTIFIER OTHERWISE NOTED. 3. WIRING RUNS ARE SHOWN DIAGRAMMATICALLY,EXACT LOCATION OF ALL E UIPMENT TO BE DETERMINED IN THE FIELD. C. 4. ALL WIRING MUST CONFORM WITH LOCAL AND NATIONAL CODES. 5. DETECTOR AND AUDIBLE ALARM DEVICE CIRCUIT POLARITY SHOULD BE OBSERVED. KEYPLAN 6. ALL DETECTOR CIRCUIT WIRING SHALL BE 1 PAIR TWISTED FIRE ALARM CABLE,#16AWG MINIMUM,14 AWG MAXIMUM,6000 DIELECTRIC,UNLESS OTHERWISE INDICATED OR SPECIFIED. SHEET TITLE. 7. WHERE ALLOWED,ALL WIRING NOT IN CONDUIT MUST BE FIRE RATED PER N.E.C.WHEN INSTALLED IN A CEILING INTERSTITIAL SPACE BEING USED _ _ _ _ _ _ _ _ _ FIRE ALARM PLANS AS A RETURN AIR PLENUM WIRING MUST BE PLENUM RATED AND FIRE RATED PER N.E.G. 8. DO NOT INSTALL SMOKE DETECTORS WITHIN 36"OF FORCED AIR OPENINGS,NOR WITHIN 12"OF FLUORESCENT LIGHTING FIXTURES. 9. THE FOLLOWING CIRCUITS MUST BE SUPERVISED,WHICH DOES NOT ALLOW ANY BRANCHING,"T-TAPPING"IS NOT ALLOWED: -- CONVENTIONAL INITIATING DEVICE CIRCUITS(IDC) I ALL ALARM NOTIFICATION APPLIANCE CIRCUITS(NAC) I LEAD. KCT 10. ELECTRICAL ROUGH-IN BACKBOX SIZES AREAS SHOWN IN E UIPMENT SCHEDULE,UNLESS SPECIFICALLY NOTED ON SYSTEM DRAWINGS. I DRAFTER: AK 11. DURING SYSTEM INSTALLATION,INSTALLING CONTRACTOR SHALL MAINTAIN A SET OF FIELD DRAWINGS,INDICATING BY RED-LINE,CHANGES IN THE THIS DESIGN IS BASED ON THE FOLLOWING ADOPTED CODES ROUTING OF ALL CONDUIT OR CABLING AND DEVICE LOCATIONS INCLUDING ADDRESS REVISIONS,PROVIDE SIEMENS,FIRE SAFETY DIVISIONS,WITH A I DATE: 03/2222 SET OF THESE MARKED UP DRAWINGS FOR AS BUILTS PURPOSES. SHEET 2015 INTERNATIONAL BUILDING CODE(IBC) 12. CIRCUIT WIRING COLOR CODE SHALL BE AS DESCRIBED IN THE CONTRACT SPECIFICATIONS. rF101 G/12. 2015 INTERNATIONAL FIRE CODE(IFC) 13. ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED WALLS AND FLOORS SHALL BE SEALED TO MAINTAIN THE FIRE SEPARATION RATING. — — — — I NFPA72 SHEET = zo 1—to Exeba -MA, Inc. F sage Conditions Agze—t see....b....—-Always—ify Scat *CONTACT RATINGS: 3.5A ®120VAC DEVICE IS LISTED FOR AIR VOLOCITY ROLLUDA ARCHITECTS,INC 3.OA ®30VDC +32'F 0'C TO 100'F 39 C) APPLICATIONS OF 300-4000 FT/MIN 105 S MAIN ST,#323 HUMIDITY: 0-9%RELATIVE HUMIDITY, WHEN USED IN CONJUNCTION WITH SEATTLE,WA 98104 NON-CONDENSING DUCT HOUSINGS AD-11P OR AD-11XPR 11E(266)6244222 FAX(2WI6244 agI ' ®r HFP-11 SMOKE STANDARD HFP-11 I m m® I DETECTOR STANDARD p� DETECTOR ® I 'FORM'C'DRY I ______________ _ __ O BASE NOTE: O I RELAY CONTACTS '� \ dQ FOR ADDITIONAL SPECIFICATIONS MODULE OPTIONS O Li \J LED o� SEE PRODUCT DOCUMENTATION. � O O O SUPERVISORY POINT = ® FORM "C- RELAY CONTACTS O O J O B 1b g w JENSEN HUGHES Qo O 5+ 1a 707 WILSHIREITE2LVD. � m SUITE 2600 ——— 5 6 7 8 9 1O 11 12 - O O LOS ANGELES,CA 90017 +1 213,630.2M I 0 WWW.JENSENHUGHES.COM JH PROJECT NO.:iKCT00173 ------------ ----- + ® � L--EOL J O p� WA N' FROM PREVIOUS 470 EOL AO FROM PREVIOUS TO NEXT DEVICE ADDRESSABLE DEVICE ADDRESSABLE DEVICE OR POWER SOURCE NEXT DEVICE OR POWER SOURCE REAR VIEW ALARM CONTACTS 125 VAC/24 VDC, DATA IN(+) (+)DATA OUT DATA IN(-)> (-)DATA OUT + + DATA IN(-) I I (-)DATA OUT S70NAlE� FROM XLS CONTROL PANEL OR J _ _ TO NEXT DEVICE OR DATA IN(+) (+)DATA OUT PREVIOUS ADDRESSABLE DEVICE L STOP IF LAST DEVICE COMBINE ALL SHIELDS AND NOT USED ISOLATE FROM GROUNDING TYPICAL ASD-PL3 SMOKE DETECTOR & B501 DETECTOR BASE TYPICAL DNR DUCT DETECTOR - WIRING DETAIL TYPICAL ADM-2RE CONTROL RELAY MODULE - WIRING DETAIL - WIRING DETAIL SCALE:NONE SCALE:NONE SCALE:NONE *END OF LINE RESISTOR COMBINE ALL SHIELDS AND REQUIRED ONLY ON�m� FIELD SELECTABLE CANDELA VALUES LAST DEVICE OF A ISOLATE FROM GROUNDING CLASS"B'CIRCUIT. NOTE: Q FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. I + +1 5S+ TOFROM PREVIOUS DEVICE TO NEXT DEVICE OR Z 27 ORE OR XLS LOOP STOP IF LAST DEVICE LD L 0 3 wo— — N N DJ a THIS AUDIBLE/VISUAL APPUANCE FEATURES o 0 EARTH GROUND SYNCHRONIZATION OF STROBES& p SYNCHRONIZATION OF TEMPORAL HORNS, Z FROM PREVIOUS WITH HORN SILENCE CAPABILITY ON A TO NEXT DEVICE DEVICE OR TWO WIRE NOTIFICATION DESIGN. OR END OF UNE POWER SOURCE (SYNCHRONIZATION SOURCE IS REQUIRED), HORN/�(_) (+) I I (+)1HORN/ . STROBE - (-)j STROBE TYPICAL MULTI-CANDELA SELECTABLE HORN/STROBE APPLIANCE TYPICAL MS-7 MANUAL PULL STATION - WIRING DETAIL WIRING DETAIL SCALE:NONE SCALE:NONE U NOTE:THE CONTRACTOR IS LLL RESPONSIBLE FOR PROVIDING ALL TIE WIRES ANCHORED CEILING HANGERS AND SUPPORT. TO STRUCTURE ABOVE 4"MINIMUM SIZE ~ TIE WIRES ANCHORED CONDUIT CEILING j = TO STRUCTURE ABOVE ``L OOO 12"MAX. r 4"MINIMUM SIZE 1~1 CONDUIT CEILING HANGER ACCEPTABLE J U (h FLEXIBLE METAL CONDUIT SHALL HERE EXCEED 6 DETECTOR O N N Lu Co J-BOX SUPPORT FEETTINLENGTH ACCEPTABLE V Z Z pD HARD LID TYPE BRACKET SIDE WALL = Z LLI Q CEILING SUSPENDED TYPE O Q= Z 000 000 CEILING 00 000 NOTE: FOR CLARIFICATION OR ADDITIONAL = 0 Lo O INFORMATION REFERENCE NFPA REQUIREMENTS. LLJ 0 I— Z O J Lu of SMOKE DETECTOR SMOKE DETECTOR PROJEC y z Q ' BUILDING IDENTIFIER: C. SHEET TITLE. FIRE ALARM DETAILS TYPICAL SMOKE DETECTOR MOUNTING DETAILS TYPICAL SMOKE DETECTOR PLACEMENT SCALE:NONE SCALE:NONE LEAD. KCT DRAFTER: AK DATE: 03/22/22 SHEET: FA3.01 Sk=ET zov d to B—d—Excbange of W sage Conditions Agzeement see www.bxwa.com-Always—ify Sc North County Community Office #84-283100-Fire Detection and Alarm Submittal item detail 84-283100-0: Fire Detection and Alarm FT�::D�� Status Created on Due date Open Feb 1, 2023 Submitted Ball in court SnoPUD NCCO (Rolluda Architects) Manager SnoPUD NCCO (Rolluda Architects) Responsible contractor James Marsh (Faber Corp.) Watchers Douglas Wilson (Snohomish County PUD) Mark Curfman (Snohomish County PUD) Adam Burke(Faber Corp.) Adolfo Florindo(Faber Corp.) Brad Raymond (Faber Corp.) David Ward (Faber Corp.) Jansen Todd (Faber Corp.) Spec section 283100 Fire Detection and Alarm Spec sub section 2831 00 Description Final Response Final Response CD Attachments JENSEN HUGHES SUBMITTAL REVIEW ❑NO EXCEPTIONS TAKEN No farther review of submittal is required. Final Response ❑MAKE CORRECTIONS AS NOTED Incorporate corrections in work:resubmittal is not required.If Contractor Comments cannot comply with corrections as noted,revise to respond to exceptions and resubmit.Record tlrewings shall reflect correction. REVISE AND RESUBMIT Revise as noted and resubmit for further review. Package FIRE DETECTION AND ALARM ❑NOT REVIEWED:STATE REASON: This submittal has been reviewed only for the limited purposes of checking for general conformance with the design concept as expressed in the Contract Documents,subject to the requirements of the Contract Documents.The contractor,not the engineer,is responsible for checking the deviation,between Provide White color for the the submital and the Contrail Documents and field recautioforcorelstio and confirming s,techniques, and quantities,for safely precautions,and methods,techniques,schedules,sequences,procedures and fabrication processing,for error and omissions in the submittals,for coordination of the work interior notification devices and and other trades,and for performing the work in a safe and satisfactory manner and in conformance with the Contract Documents. Red for the exterior - RAI JENSEN E , By: Date:02115/2023 Created by SnoPUD NCCO with Autodesk®Construction Cloud'"on Feb 1,2023 at 8:47 AM PST Page 1 of 2 North County Community Office #84-283100-Fire Detection and Alarm Ball in court Sent Due Returned Response/Action Attachments Submitted James Marsh 28 31 00 Fire Detection (Faber Corp.) Feb 1, 2023 Jan 31, 2023 Feb 1, 2023 Submitted and Alarm Submittals.pdf Comments - Sent for review SnoPUD NCCO (Rolluda Architects) Feb 1, 2023 - - Sent for review Comments - Created by SnoPUD NCCO with Autodesk®Construction Cloud'"on Feb 1,2023 at 8:47 AM PST Page 2 of 2 FABER CONSTRUCTION CORPORATION Project:2191.3 North County Community Office rA E Lynd n,Washington Road 17601 ngth Ave NE 23 Lynden,Washington 98264 Arlington,Washington 98223 P: (360)354-3500 CONSTRUCTION F:(360)354-0335 Submittal #28 31 00-084.0 - Fire Alarm and Detection 28 31 00 - Fire Detection and Alarm Revision 0 Submittal Manager James Marsh(FABER CONSTRUCTION CORPORATION) Status Open Date Created Jan 31,2023 Issue Date Jan 31,2023 Spec Section 28 31 00-Fire Detection and Alarm Responsible SEAHURST ELECTRIC, INC Received From Contractor Received Date Submit By Jan 31,2023 Final Due Date Lead Time Cost Code Location Type Product Information Approvers Ball in Court James Marsh(FABER CONSTRUCTION CORPORATION) Distribution Description Mark, Please see attached submittal Fire Alarm Detection for your review and approval. Let us know if you have any questions or need additional info. Thanks! James Submittal Workflow Name Sent Date Due Date Returned Date Response These items have been received by Faber Construction Corporation,initially reviewed for compliance with the General Information Attachments contract documents,and are being sent on to the architect for further review and approval: By: I :� g Date: 01/31/2023 These material submittals have been reviewed and deemed to meet the intent of the contract documents, and are,to the best of our knowledge,in compliance with the project plans and specifications. ❑ Approved as Submitted ❑ Approved as Noted ❑ Rejected Im ❑ Revise and Resubmit CONSTRUCTION By: Date: This review does not remove any obligation by the subcontractor or supplier to provide and install FABER CONSTRUCTION CORPORATION Page 1 of 1 materials that are in full compliance with all referenced material standards and project documents,nor relieve any warranty obligations imposed by those documents EAHURST Letter of Transmittal LECTRIC To: Faber Construction Date: 1/27/2023 6951 Hannegan Road Job No.: 117510 Lynden,Washington 98264 Job Name: Snohomish County PUD Arlington Attention: James Marsh Re: 28 3100 Fire Alarm and Detection WE ARE SENDING YOU: Shop drawings X Attached Under separate cover via Copy of letter Prints Plans As required Change order Specifications For review and comment X Submittals Samples —Forbids due: Other Copies Date No Description 1 1/27/2023 28 3100 Fire Alarm and Detection THESE ARE TRANSMITTED AS CHECKED BELOW: x For approval Approved as submitted Resubmit copies for approval For your use Approved as noted Submit copies for distribution As required Returned for corrections Return corrected prints For review and comment Return to this office For bids due: Prints returned after loan to us Remarks: Copy To: Job File Signed: CONTRACT ADMIN Project: Snohomish County PUD-Arlington 24339- PWC North County Community Office PUD 1- FA 24339-C-2- PWC North County Community Office PUD Fire Alarm Bldg B 24339-C-1- PWC North County Community Office PUD Fire Alarm Bldg C FA Submittal Plans PWC North County Community Office PUD 1 - FA Job Number: 24339 24339 -PWC North County Community Office PUD 1 - FA PWC North County Community Office Table of Contents Spec # Section Manufacturer Doc Name Doc # Fire Alarm Gamewell - FCI E3 Cutsheet 1 Gamewell - FCI HPF PS10B Cutsheet 2 Gamewell - FCI 1100 0450 Cutsheet 3 Space Age IAMEFAD Cutsheet 4 Gamewell - FCI FlexGF506R Cutsheet 5 System Sensor SCWL Cutsheet 6 System Sensor PC2WL Cutsheet 7 System Sensor SWL Cutsheet 8 System Sensor P2WL Cutsheet 9 System Sensor P2WK Cutsheet 10 Gamewell - FCI ASD PI-3 IV Cutsheet 11 Gamewell - FCI ATD L3 IV Cutsheet 12 Gamewell - FCI MS 7AF Cutsheet 13 Gamewell - FCI AOM 2RF Cutsheet 14 Functional Devices Inc. RIBO1 BDC Cutsheet 15 Gamewell - FCI AMM 2F Cutsheet 16 Gamewell - FCI ASD PL3R IV Cutsheet 17 Gamewell - FCI RTS151 KEY Cutsheet 18 Fire Alarm 1/20/23,3:21 PM Gamewell I E3 series0100011110ed FIRE CONTROL INSTRUMENTS Fire and MNS System by Honeywell Description Combined Fire and MNS System The Gamewell-FCI, E3 Seriesg Broadband Emergency - Voice Evacuation System and the E3 Series Broadband Networked Fire Alarm System can be combined on the common network to form a combination Fire and Mass j Notification (MNS) System in accordance with the NFPA ; and UL Standard UL2572 requirements. The E3 Series 1 modules, nodes and control panels are peer-to-peer, self- L i regenerating, token ring passing networks consisting of 2 to 64 nodes,or consisting of up to 122 nodes with the addi- tion of an ANX. The E3 Series System is a modular design.This adaptable design allows a wide range of configurations to form an integrated, distributed fire alarm system in combination with the audio evacuation for both Fire and Mass Notifica- tion functions as desired.The design also allows for its use E3 Series Combined Fire and MNS System as a dedicated,standalone Mass Notification System with- Features out a fire alarm service. The network communication conveys all of the following Listed under ANSI/UL'"'Standard UL2572 for Fire Alarm and Mass Notification control functions: Mass Notification. • Listed under ANSI/UL Standard 864,9th Edition. • Audio evacuation IBC Seismic Certified • Voice paging Offers the Base Platform for the Emergency • Fire fighter communications over a single pair of wires Communications System. or fiber-optic cable Provides true.seamless and scalable integration for Fire and Mass Notification that is configured applying A Region contains only one ACU (Autonomous Control the E3 Series building blocks using up to 122 nodes. Unit), and multiple LOCs (Local Operating Consoles). Includes a cost-effective,supervised."Style 7"network Speaker circuits cannot be shared by Regions.The individ- wiring using a single pair of wire or fiber-optics at 625K ual node types and modules in the E3 Senes System fam- baud. ily are interconnected to form the ACU and the LOC panels Contains a compact,Local Operating Console(LOC) for Mass Notification as well as the following: that is designed for installation in lobbies,doorways and • Fire Command hallways allowing quick access to do the following: Control and Detection Broadcast MNS announcements. • AV Signaling View the System Status messages. • Designed with a user-friendly,color touchscreen display • Audio functional units within the overall network system that provides all Fire and MNS Events at all locations. • Installs a simple configuration of multiple LOCs with expandability from 16 to 64 programmable switches for status,message activation and control. SIGNALING U� LISTED S1869 E3 Senes®:s a registered trademark of Honeywell Internawnal Inc. S1949 ULS is as registered trademark of Underwnter's Laboratones Inc. �$® GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161•Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change vnthoul notice.No responsibility is assumed by Gamewell-KI for their use 62014 by Honeywell lntemabonal Inc, All rights reserved. www.gamewell-fci.com 9021-60758 Rev.B page 1 of 3 1/1 SERIES 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Gamewell-FCI.The HPF-PS6 is a 6 amp and the HPF-PS10 is a 10 amp,remote power supply with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a standalone power supply.The PS Series provides 24 VDC power for NACs(notification appliance circuits)configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync protocol options.The PS Series also provides auxiliary power,constant or resettable,suited for detectors,annunciators,door holders,and other fire alarm system peripherals.The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS HPF-PS6/10 • Up to five(6 amp model)or seven(10 amp • Two Form C normally-closed trouble relays model)independently-configurable,power- for AC Trouble and General Trouble limited output circuits for: • 6 or 10 amp full load output,respectively, —Class B and/or Class A NACs with 3 A maximum/circuit —Class B and/or Class A resettable or non- • Individual NAC power and trouble LEDs for resettable 24V auxiliary power diagnostic efficiency —door holder power • Trouble history mode for diagnostic support • Converts from Class B to Class A wiring • Wide range end-of-line supervision value without losing any outputs using the ZNAC- (normal:2-27K ohms) PS converter card(sold separately) • Selectable earth fault detection(enable or • Optimal for powering four-wire smoke disable) detectors,annunciators,and other system • AC trouble report delay timer peripherals requiring regulated power • Completely configurable via onboard DIP • Optional addressable control,monitor,and switches,no extra software required relay modules and power-supervision relay • Self-contained in compact,locking cabinet (EOLR-1) constructed of heavy gauge steel with a • Configurable for ANSI°Temporal 3 or corrosion-resistant powder coat chip and Temporal coded output scratch-resistant finish HPF-PS6110B • UL-Listed NAC synchronization using • Cabinet designed with ten double • Works with any UL 864 FACP which utilizes System Sensor',Wheelock',Gentex°,or knockouts and a removable door for ease of an industry-standard reverse-polarity AMSECO°appliances installation and wiring notification circuit • Synchronization can be triggered from • Includes integral battery charger capable of • HPF-PS6/10includethe-Honeywell Power FACP NAC/remote sync outputs,cascaded charging up to 33 AH batteries Products lock set(PN:17059)and key(PN: power supply,or a control module,single or • Cabinet can house two 7 AH or 18 AH 17051) multi,which may be housed within the batteries power supply cabinet • Battery charger may be disabled via DIP • Ability to cascade up to four power supplies switch for applications requiring larger • Two(6 amp model)orthree(10 amp model) batteries and external battery charger fully-isolated input/control circuits which • Removable terminal blocks accommodate Honeywell can be programmed to any output up to 12 AWG(3.1mm2)wire ORDERING INFORMATION HPF-PS6:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS613:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black HPF-PS10:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS10B 10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black ZNAC-PS:Optional Class A converter card,sold separately AOM-2SF:Addressable Control Module for one Class B or Class A zone of supervised,polarized Notification Appliances.Notification Appliance Circuit option requires external 24 VDC to power notification appliances. AOM-2RF:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch AMM-4F:Addressable Monitor Module for one zone of normally open dry-contact initiating devices.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Class B or Class A AMM-21F:Dual Monitor Module.Same as AMM-4F except it provides two inputs for Class B wiring only AMM-21RIF:Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only MMO-6SF:Six-circuit supervised control module MMO-6RF:Six Form-C relay control module EOLR-1:12/24VDC end-of-line relayfor monitoring four-wire smoke detector power BAT-1270-BP:Battery,12 volt,7.0 AH,5-pack(two required) BAT-12180-BP:Battery,12 volt,18AH,2-pack BAT-12330:Battery,12 volt,33AH SEISKIT-MULTI-1:Seismic kit for the PS Series.Includes bracket and hardware for two 7AH or two 18AH batteries. 17070:Alternate Honeywell Gamewell-FCI lock set,PK-625,3/8" cam Page 2 of 3—9021-61096:B•1/25/2021 HPS SERIES TECHNICAL SPECIFICATIONS PRIMARY(AC)POWER SECONDARY POWER(BATTERY) HPF-PS6(B):120VAC,50/60 Hz,5.OA CHARGING CIRCUIT Sensor' maximumtrademarkSupports lead-acid batteries only HPF-PS10(B) 120VAC,50/60 Hz,6.2 A • Float-charge voltage:27.6 VDC International,Inc.Wheelock' maximum Maximum current charge:1.5 A registered trademark of Cooper Wire Size:#12-14 AWG with 600 V • Maximum battery capacity:18 AH(inside Technologies Company.Gentexl is insulationregistered _' _' trademark' cabinet) COMMAND INPUT CIRCUIT • Maximum battery charging capacity:33 AH (external cabinet) registered trademark of Potter Trigger Input Voltage:9 to 32 VDC Electric Signal Company, Trigger Current:2.0 mA(16-32 V);Per PHYSICAL ANSIO is a registered trademark of Input:1.0 mA(9-16 V) Dimensions:20.0"H x 14.5"W x 3.5"D(cm: the American National RELAY CIRCUITS 50.8H x 36.83W x 8.91D) Institute,Inc. Trouble Contact Rating:4 A at 24 VDC Weight:with two 7Ah batteries is 24 pounds by Honeywell 'nal (10.9 kg),with two 18 AH batteries is 39 Inc.All rights ' OUTPUT CIRCUITS pounds(17.7 kg) Unauthorized use of this document • 24 VDC filtered STANDARDS AND CODES is strictly prohibited. • HPF-PS613:TB8-TB9—1A Regulated,3A The HPF-PS complies with the following This document is not - •-•tobe special applications;TB10-TB12—0.3A standards: usedfor installation purposes. Regulated,3A special applications NFPA 72:National Fire Alarm Code . • • • .• . • • HPF-PS10B:T138JI311-1.5A Regulated, UL 864:Standard for Control Units for Fire up-to-date• ' accurate.We cannot 3A special applications;TB12-TB14—0.3A Alarm Systems(NAC expander mode) cover all specific applications or Regulated,3A special applications UL 1481:Power Supplies for Fire Alarm anticipate all "' • 6.0 A(HPF-PS613)or 10.0(HPF-PS10B) Systems specifications are subjectto change maximum total continuous current for all without notice. outputs AGENCY LISTINGS AND APPROVALS Country of origin:USA These listings and approvals apply to the modules specified in this document.In some cases,certain modules or applications may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest listing status. UL Listed:S24562 CSFM:7315-1637:0505 FDNY Approved FM Approved Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT06472-1610 Honeywell 203.484.7161 � 9021-61096 B 01/21 www.gamewell-fci.com ©2021 Honeywell International Inc. Q[0*m;R _ GamewelL E3 Series - FIRE CONTROL INSTRUMENTS Cabinets by Honeywell Description Cabinets for the E3 Series® The E3 Series® Expandable Emergency Evacuation Sys- tem by Gamewell-FCI offers several cabinet size options. These cabinet options allow for neat, sturdy, attractive installations. The E3 Series cabinet assembly is a com- pact, wall-mounted enclosure. A typical cabinet includes a backbox and an outer locking door. In addition, there are several inner door choices and mounting plates to accom- modate a variety of E3 sub-assemblies. Each cabinet backbox includes mounting patterns for plates to aid the installer in arranging and securing the sub- assemblies to the backbox. Backbox knockouts are also i positioned at numerous points to allow a conduit access 3 into the enclosure. The following four Annunciator cabinet sizes provide the maximum flexibility that can meet any application. • Cabinet AA offers 2 slot or 3 slot options to accommodate any of the following configurations: Inner door,2 slots allows space for one LCD-E3 or LCD-SLP and one ASM-16. E3 Series®Cabinets -Inner door,3 slots allows space for any combination of three modules:ASM-16, NGA or an ANU-48. Features • Cabinet Al houses one NGA or one ASM-16/ANU-48. • Cabinet A2 accommodates a single LCD-E3. • E3BB-FLUSH-LCD or E3BB-NGA-FLUSH. IBC Seismic Certified. • 16-gauge steel backbox. E3BB-R-BSIim or B-Slim contains the 600 Series cabinet. Removable outer and inner doors. Cabinet B includes a mounting plate that contains a space Inner door bonding strap used to provide electrical for the ILI-MB-E3/IL195-MB-E3, PM-9/PM-9G sub-assem- continuity for grounding. blies and batteries set inside the backbox. Additional sub- Backbox and door ground studs provide positive assembly options mounted on the backbox include the grounding. 180'opening door with full clearance. DACT-E3 and RPT-E3. The 2 slot inner door houses the Available in either black or red. following options: Lexan®windows appear on the doors of most cabinets, • one LCD-E3 module and except the Cabinet"C"and"D" INX cabinets and the • either one ASM-16/ANU-48 or one NGA module INX CAB-B cabinet which contain louvered doors. • 90'opening door with zero clearance. Both C and D size Command Center cabinets house a vari- Keylock with quarter turn latch. ety of E3 Broadband sub-assemblies in multiple configura- Trim Ring accessories available. tions that provide a solution to a wide range of applications. Two flexible inner door panel selections are available for C and D size Command Center cabinets that may contain a fire fighter's phone handset, a microphone, and optional modules to meet the facility operation requirements. (Note: See Inner Door and Backbox Mounting Capacities on page 3 and 4). SIGNALING U FM City of MEA r�J`- Chic Cit Chicago y of �'0•""_-- LISTED APPROVED Approved Approved Denver E3 Series®and FocalPoint®area registered trademark ofHoneywell International hie. S1869 3025415 FDNY: 7165-1703:0125 class' Approved , 1exan®is a registered trademark of GE Plastics,a subsidiary of General Electric Company COM-6077 High Rise r...a'=i�f— VMN45894-01C ISO 9001 GAMEWELL-FCI " '...." 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. 2015 by Honeywelllnternational Inc. Allnghts reserved. www.gamewell-fci.com 9020-0649 Rev.T page 1 of 4 Ordering Information Ordering Information (Continued) Part Number Description Part Number Description Cabinet"AA"Size Cabinet"C"Size(Continued) Dimensions: 19 1/4"W x 10"H x 4 1/4"D E3-INCC-CPLATE Command Center module mounting (49 Wx25 Hx 11.4 Dcm) plate,"C"Size E3BB-BAA Enclosure, Black,"AA"(LOC)Size E3-INXCPLA'IF Transponder module mounting plate,'C"Size E3BB-RAA Enclosure, Red, "AA"(LOC)Size E3-ILI-CPLATE Intelligent loop module mounting plate`C"Size E31 D2-TA Inner Door,2 Slots, Cabinet"D"Size: (INCC-TEL&ASM-16) Dimensions: 19 3/8"W x 41"H x 4 1/2"D E31D2-A Inner Door,2 Slots, (49 Wx 104 Hx 11 Dcm) (LCD-E3 or LCD-SLP&ASM-16) E3BB-BD/INCC Enclosure,Command Center,Black,`IY'Size E31D3-A Inner Door,3 Slots, E3BB-RD/INCC Enclosure,Command Center,Red,`IY'Size (NGA,ASM-16 and MIC) E31D2-D Assy, Inner Door,2-Bay,"D"Size Cabinet"Al"Size: E31D3-D Assy, Inner Door,3-Bay,"D"Size Dimensions: 8 3/4"W x 10"H x 4 1/2"D E3BB-BD/INX Enclosure,Transponder, Black"D"Size (22 Wx25 Hx 11.4 Dcm) E3BB-RD/INX Enclosure,Transponder, Red,"D"Size E3BB-BAA1 Remote Enclosure, Black,w/Inner Door, E34NCC-D-PLATE Command Center module mounting 1 Slot, (NGA) plate,"D"Size E3BB-RAA1 Remote Enclosure, Red,w/Inner Door, E3-INX-D-PLATE Transponder module mounting plate,"D" 1 Slot, (NGA) Size Cabinet"A2"Size: Optional Extender Plates Dimensions: 13 1/4"W x 10"H x 3 1/2"D AM-50 Plate AM-50 Extender Plate (40Wx25 Hx9 Dcm) FPT-GATE-3-EXT FPT-GATE-3Extender Plate E3BB-BA2 Remote Enclosure,Black,w/Inner Door, Optional Accessories 1 Slot, (LCD-E3 or LCD-SLP) E3BB-RA2 Remote Enclosure,Red,w/Inner Door, 1 1100-0450 j Command Center,blank plate,single size Slot, (LCD-E3 or LCD-SLP) E3-BP Inner door panel, blank,double size Flush Cabinet Al Annunciators: 90375 PM-9/PM-9G Hardware E3BB-FLIJSHLCD CAB A2 Remote Flush LCD ANN with 18739 Adapter Plate Kit Keyswitch operation E3-TRIMKIT-A Trim kit for"A"/"AA"size enclosure, E3BB-NGA-FLUSH CAB A2 Remote Flush NGA ANN with black Password protected E3-TRIMKIT-A1 Trim kit for"Al"size enclosure, black Cabinet"B-Slim"Size: (Retrofit Kits) E3-TRIMKIT-A2 Trim kit for"A2"size enclosure, black Dimensions: 14"W x 20"H x 4 1/2: D E3-TRIMKIT-B Trim kit for"B"size enclosure, black (35.5 Wx50.8 Hx 11 Dcm) E3-TRIMKIT-C Trim kit for"C"size enclosure, black E3BB-RBSLIM Assy, Enclosure, B-SLIM, Red with E3-TRIMKIT-D Trim kit for"D"size enclosure, black Backplate and LCD-E3 Keyswitch plate. Bulk Amplification 117600-RETRO17IT Door and Cab mounting plates,disable key switch and door lock(PK-625)for Part Number Description E3 Series upgrade. AA-100 100 W Audio Amplifier, @70.7 VRMs Cabinet"B"Size: with 120 VAC. Dimensions: 19 3/8"W x 19 3/8"H x 4 1/2"D AA-120 120 W Audio Amplifier, @25 VRMs (49 Wx49 Hx 11 Dcm) with 120 VAC. E3BB-BB Assy, Backbox Enclosure, Black,"B" ACT-1 Audio coupling transformer,for audio Size systems w/multiple supplies. E3BB-RB Assy, Backbox Enclosure, Red,"B"Size FCI-CHG-120 Battery Charger, 25-120 A/H Gel cell. E31D2-B Inner Door,2 Slots,"B"Size FCI-LBB Battery box,accommodates batteries up 1100-0460 INX-Transponder 19"(cm)Backbox with to 55 A/H, (Black). Door, Black. Cabinet C: Dimensions: 19 3/8"W x 19 3/8"H x 4 1/2"D FCI-DR-C4B Large Battery Backbox,Blank door,lock (49 Wx49 Hx 11.43 Dcm) &keys,for backbox accepting 3 chassis, Cabinet"C"Size: (Black). Dimensions: 19 3/8"W x 30"H x 4 1/2"D FCI-DR-C4BR Blank door, lock&keys,for backbox (49 Wx76Hx 11 Dcm) accepting 3 chassis, (Red). E3BB-BC/INCC Enclosure,Command Center,Black,`C"Size SBB-C4 Backbox, 3 chassis, (Black) E3BB-RC/INCC Enclosure,Command Center,Red,`C"Size Cabinet D: E31D2-C Assy, Inner Door, Command Center, FCI-DR-D4B Blank door, lock&keys,for backbox 2-Bay"C"Size accepting 4 chassis, (Black) E31D3-C Assy, Inner Door, Command Center, FCI-DR-D4BR Blank door, lock&keys,for backbox 3-Bay"C"Size accepting 4 chassis, (Red) E3BB-BC/INX Assy,Transponder, Black,"C"Size SBB-D4 Backbox,4 chassis, (Black) E3BB-RC/INX Assy,Transponder, Red,"C"Size GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0649 Rev.T page 2 of 4 www.gamewell-fci.com Seismic Battery Bracket Kits Inner Door Mounting Capacity (Cont'd) Part Number Description Number Components 90516 7100-Slim 7 A/H Seismic Battery Bracket Kit Cabinet C E3 B-Slim 7 A/H Seismic Battery Bracket Kit E31D2-C, Cabinet C, Inner Door,2 Slots 90517 7100-Slim 12 A/H Seismic Battery Bracket Kit 1 LCD-E3 Display and E3 B-Slim 12 A/H Seismic Battery Bracket Kit 5 Any combination of ASM-16/ANU-48, NGA or 90518 E3 CAB-B 7 A/H Seismic Battery Bracket Kit Microphone Assemblies E3 CAB-C 7 A/H Seismic Battery Bracket Kit 1 Telephone Assembly E3 CAB-D 7 A/H Seismic Battery Bracket Kit NetSOLONS-M7 All Seismic Battery Bracket Kit E31D3-C, Cabinet C, Inner Door,3 Slots NetSOKD71007AASeismic Battery Bracket Kit 7 Any Combination of ASM-16/ANU 48, NGA,or 90519 E3 CAB-C(INX only)12 A/H Seismic Microphone Assemblies Battery Bracket Kit 1 Telephone Assembly E3 CAB-D(INX only)12 A/H Seismic Battery Bracket Kit Cabinet D NetSOLO NS-INX 12 A/H Seismic Battery E31D2-D, Cabinet D, Inner Door,2 Slots Bracket Kit 1 LCD-E3 Display 90520 E3 CAB-B 18 AIHSeismic Battery Bracket Kit 11 Any Combination of ASM-16/ANU-48,or NGA E3 CAB-C 18 A/H Seismic Battery Bracket Kt or Microphone and E3 CAB-D 18 A/H Seismic Battery Bracket Kit 1 Telephone Assembly E31D3-D, Cabinet D, Inner Door,3 Slots Retrofit Kits 13 Any Combination of ASM-16/ANU-48, NGA or For information on the Gamewell and 7200 Retrofit Kits, Microphone Assemblies refer to the following Data Sheets. 1 Telephone Assembly 9021-60678 Gamewell Retrofit Kits Data Sheet Backbox Mounting Capacity 9021-60733 7200 Retrofit Kits Data Sheet Number Components Specifications E3BB-BAA, Enclosure,"AA (LOC)Size, Black Inner Door Mounting Capacity 1 INI-VG Series Voice Gateway Number Components E3BB-BA,Al Size Box/Door, Black Cabinet A 1 RPT-E3 Network Repeater E31D2-A, Cabinet A, Inner Door,2 Slots E3BB-BB, B Size Box/Door, Black 1 LCD-E3 Display and 1 PM-9/PM-9G Power Supply 1 ASM-16/ANU-48 1 ILI-MB-E3/ILI95-MB-E3 and E31D2-TA Assembly, Door, Inner,TEL-E3 1 Additional ILI-MB-E3/ILI95-MB-E3 Loop Interface or ANX or E31D3-A, Cabinet A, Inner Door,3 Slots 1 DACT-E3 Digital Communicator and 1 NGA or ASM-16 1 RPT-E3 Network Repeater 2 ASM-16s/ANU-48s INX CAB-B Mounting Plate Cabinet AA 1 PM-9 or PM-9G 1 Microphone 1 INI-VGX Cabinet Al 4 AM-50 Series amplifiers E31D-Al Cabinet Al, Inner Door, (Included with Box) E3-INCC-C Plate 1 NGA or ASM-16 1 PM-9/PM-9G Power Supply Cabinet A2 1 INI-VG Series Voice Gateway E31D-A2 Cabinet A2, Inner Door, (Included with Box) 1 ILI-MB-E3/ILI95-MB-E3 Loop Interface and 1 LCD-E3 1 Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop Cabinet B Interface or E31D2-B,Cabinet B, Inner Door, (Included with Box) 1 DACT-E3 Digital Communicator and 1 LCD-E3 Display and one ASM-16/ANU-48 1 RPT-E3 Network Repeater 1 NGA and one ASM-16/ANU-48 1 Optional AM-50 or FPT-GATE-3 Extender Plate B-Slim Cabinet 1 LCD-E3 Display and one RPT-E3 or one DACT-E3 1 ILI-MB-E3 or one ILI95-MB-E3 1 PM-9 or one PM-9G GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9020-0649 Rev.T page 3 of 4 Backbox Mounting Capacity Backbox Mounting Capacity Number Components Number Components E3-I1-I-C Plate E3BB-BD, D Size Box/Command Center(Voice), Black 1 PM-9/PM-9G Power Supply 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 or ILI95-MB-E3 1 INI-VG Series Voice Gateway 2 Additional ILI-MB-E3/ILI95-MB-E3 or ILI-S-E3 4 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface /I1-I95-S-E3 or ANX and 1 DACT-E3 1 Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop 1 RPT-E3 Interface or 1 Optional FPT-GATE-3 Extender Plate 1 DACT-E3 Digital Communicator and E3-INX-C Plate 1 RPT-E3 Network Repeater 1 PM-9/PM-9G Power Supply with one PM-9/ 1 Optional FPT-GATE-3 Plate PM-9G Adapter Plate E3BB-BD, D Size Box/Command Center, Black 1 INI-VGX Voice Gateway 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 Loop Interface and 7 ILI-MB-E3/ILI95-MB-E3/ANX Loop Interface 1 AdditionallLI-MB-E3/LI95-MB-E3/ANX and 1 DACT-E3 Digital Communicator and 1 Additional ILI-MB-E3/ILI95-MB-E3/ANX Loop 1 RPT-E3 Network Repeater Interface or 1 DACT-E3 Digital Communicator and 4 AM-50 Series Amplifier 1 RPT-E3 Network Repeater 1 Optional FPT-GATE-3 Extender Plate 1 Optional FPT-GATE-3 Extender Plate E3-INCC-D Plate 1 PM-9/PM-9G Power Supply Optional Extender Plates 1 ILI-MB-E3 or ILI95-MB-E3 AM-50 Extender Plate 4 Additional ILI-E3 Series or I1-I95-E3 Series or 1 AM-50-25 or AM-50-70 ANX FPT-GATE-3 Extender Plate 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 FocalPointR�Gateway 1 INI-VG Series 1 PNET-1 1 Optional AM-50 or FPT-GATE-3 Extender Plate E3-INX-D Plate 1 PM-9/PM-9G Power Supply 1 ILI-MB-E3 or ILI95-MB-E3 1 DACT-E3 Digital Communicator 1 RPT-E3 Network Repeater 1 INI-VG Series 4 AM-50 Series Amplifier 1 Optional FPT-GATE-3 Plate GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0649 Rev.T page 4 of 4 www.gamewell-fci.com 0 S� FFAD Fire Alarm Documents The Space Age Electronics eFAD USB storage device has been developed to be a code compliant solution to a mandated item specified by the National Fire Code NFPA L FIRE 72 section 6.2.2.1 states, "A record of installed software ALARM and firmware version numbers shall be maintained at the DOCUMENTS location of the fire alarm control unit." The eFAD is a designed solution to prevent the reoccurring problem of non billable service calls and lost revenue. When your service technician arrives to your customer's location and the fire alarm software is not available due to it not being on site, not the right version "A record of installed software and or CD is damaged, it not only takes money directly from firmware version numbers shall be your bottom line, it can cause customer aggravation. maintained at the location of the fire These types of occurrences are typically caused by the alarm control unit." previous technician forgetting to put the software back or the end-user misplacing it. None the less this causes Standard Features: downtime and customer retention issues. • Single gang electrical back box • Standard Decora cover plate The eFAD eliminates the need for the industry standard • Can be mounted with other infinity CD's when making changes to the fire alarm software by single gang products storing your software on 2GB USB flash drive. It stores • Ensures that the files are always at your fire alarm software safe and secure, eliminating the jobsite the occurrences of the software not being on site when • Easy access to a USB B port to files • 2 GB flash drive, store electronically technicians arrive to service the system. Along with your your T&I records, AS Built Drawings fire alarm software you can store your test & inspection & service reports. documents, service records, manuals &AS built drawings • Make changes to the fire alarm soft- for the system. Using a standard USB B connector it ware without having to make a new allows you to plug in with any standard SB printer cable CD. • Durable steel frame mounts into an to upload or download information. Simply erase the old Infinity IGB Box or a standard electri- version and up load the new one with your changes. cal back box and securely holds the cover IGP plate. •�% • ISO 9001 ; INFINITY SERIES REGISTERED � �� odular Com onents Space Age Electronics, Inc. [07] COMPANY ADA www.isae.com 800.486.1723 Toll Free NFPA Made In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0571 LT10571 Rev.A 1/2 No Excuses, Just Solutions! 'SPACEAGE zMW ELECTRONICS, INC. Specifications: The fire alarm documents shall be digitally stored within 6ft of the FACU panel.A Space Age Electronics eFAD shall be installed in a single gang electrical back box or a IGB series back box with a red Decor plate cover. The unit will be permanently marked "Fire Alarm Documents" and will not be able to be removed from the surface. The unit will install like an electrical device and be securely fastened. The eFAD unit shall have a minimum capacity of 2GB's of digital storage. The access will be a USB type B connector. ' 1.5" O 0 Q M RE 4.25„ ALARM PO DOCUMENTS 1.29" EiOF-' - �j Ordering Information: Part# Description �NFINITY SERIES odularComponents IAMEFAD eFAD Fire Alarm Documents Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0571 LT10571 Rev.A 2/2 _ Gamevimil Flex GF506R_ ®INMUU ENTS by Honeywell Description Agent Release Control Panel General The Flex GF506R is a six-zone FACP used for single and dual hazard agent releasing applications. The Flex GF506R provides reliable fire detection. It also offers sig- naling and protection for commercial, industrial, and insti- tutional buildings that require agent-based releasing. The Flex GF506R is compatible with System Sensor's i3 detec- tors. The i3 detectors are conventional smoke detectors that transmit a maintenance trouble signal to the FACP that indicates the need for cleaning. It also transmits a supervi- sory `freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the Flex GF506R control panel is compatible with the following conventional input devices: Flex GF506R • two-wire and four-wire smoke detectors Features • pull stations • waterflow devices and tamper switches Listed under UL Standard 864, 9th Edition. • other normally-open contact devices IBC Seismic Certified. For a complete listing of compatible devices, refer to the Designed for Agent Releasing NFPA Standards: 12, Gamewell-FCI Device Compatibility Document, 12A, 12B,2001 and 2010. P/N:52195. Disable/Enable control per input zone and output zone. There are four outputs that are programmable as NACs Extensive transient protection. (Notification Appliance Circuits)or releasing circuits.Three Dual hazard operation. programmable Form-C relays (factory programmed for Adjustable pre-discharge,discharge and waterflow Alarm,Trouble, and Supervisory), and the 24 VDC special delay timers. application resettable and non-resettable power outputs Cross-zone(double-interlock)capability. are included on the main circuit board. The Flex GF506R Six programmable Style B(Class B)IDCs(Initiating supervises all wiring,AC voltage, battery charger, and bat- Device Circuit)with optional Class A wiring. tery level. 3 • System Sensor i series detectors compatible. The activation of a compatible smoke detector or any nor- Four programmable Style Y(Class B)output circuits- mally open fire alarm initiating device will do the following: (special application power)with Style Z(Class A)option. • Turn on audible and visual signaling devices. Strobe Synchronization: • Light an indicator. System Sensor -Cooper-Wheelock -Gentex • Display alarm information on the panel's LCD. Faraday -Amseco • Sound the piezo sounder at the FACP. Three programmable Form-C relays. • Activate the FACP alarm relay. 7.0 amps total 24 VDC output current. • Operate an optional module used to notify a remote Resettable and non-resettable output power. station or initiate an auxiliary control function. • Built-in Programmer. SIGNALING r' i 3TM'is a trademarkofFlone 11lntematanal Inc. ul- FM 4 s re ywe _ ;; Reference Certificate ® LISTED APPROVED — - of Compliance UL is a registered trademark of Underwriter's Laboratories Inc. S624 7165-1703:0171 VMA45894-02C (Revision 1) ISO 900 QOGl1iY%YSiEMB GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. C2013bylioneyaell International Inc. All rights reserved. www.gamewell-fci.com 9021-60467 Rev.D page 1 of Features (Continued) Features (Continued) Controls and Indicators • ANN-BUS for connection to optional The panel provides the following LED Indicators: (up to 8 total of any of the following): Fire Alarm(red) Alarm Silenced(yellow) GFANN-80 Remote LCD Annunciator Supervisory(yellow) Discharged (red) GFANN-S/PG Printer Module Trouble(yellow) Pre-discharge(red GFANN-RLY Relay Module indicator) GFANN-LED Annunciator Module AC Power(green) Abort(yellow indicator) • 80-character LCD display(backlit). • Real-time clock/calendar w/daylight savings time Control Buttons control. • Acknowledge System Reset(lamp test) • History Log with 256 event storage. • Alarm Silence Drill • Piezo sounder for alarm,trouble and supervisory. AC Power—TB1 • 24 volt DC operation. The AC Power-TB1 for each panel is listed below: • Low AC voltage sense. GF506R: 120 VAC, 50/60 Hz,2.3 amps • Outputs Programmable for the following: 2 Wire size: minimum#14 AWG(2.0 mm )with 600V -Releasing circuits or NACs • insulation. NACs programmable for the following: Supervised, non power-limited Silence Inhibit Auto-Silence Battery(sealed lead acid only)—J12: Strobe Synchronization The Battery(for sealed lead acid only)-J12 specifications Selective Silence(horn-strobe mute) are listed below. Temporal or Steady Signal Maximum Charging Circuit-Normal Flat Charge: Silenceable or Non-silenceable -27.6 VDC @ 1.4 amp. Supervised, non power-limited. Release Stage Sounder Maximum Charger Capacity: • Extensive transient protection. -26 Amp Hour battery(two 18 Amp Hour batteries can • Automatic battery charger with charger supervision. be housed in the FACP cabinet. Larger batteries • Optional Dress Panel DP-51050(red). require separate battery box such as the BB-26 or • Optional Trim Ring TR-CE(red)for semi-flush BB-55). mounting the cabinet. Minimum Battery Size: 7 Amp Hour • Optional CAC-5X Class A Converter Module for Outputs and IDCs. Initiating Device Circuits -TB4 and TB6 • Optional 4XTMF Municipal Box Transmitter Module. The Initiating Device Circuits for TB4 and TB6 • Optional Digital Alarm Communicators(411,411 LID, specifications are listed below. 411 UDAC). Alarm Zones 1 -5 on TB4 • Alarm Zone 6 on TB6 Programming and Software Supervised and Class 2 Power-Limited circuitry The programming software offers the following features: Style B(Class B)wiring with Style D(Class A)option • Custom English labels(per point)may be manually Normal Operating Nominal 20 VDC entered or selected from an internal library file. Voltage: • Programmable Abort operation. Alarm Current: 15 mA minimum • Three programmable Form-C relay outputs. Short Circuit Current: 40 mA max • Pre-programmed and custom application templates. Maximum Loop 100 Ohms • Continuous fire protection during online programming Resistance: at the front panel. End-of-Line Resistor: 4.7KOhms, 1/2 watt • Program Check automatically catches common errors (PN71252) not linked to any zone or input point. Standby Current: 4 mA For a list of compatible devices, refer to the Gamewell-FCI User Interface Device Compatibility Document, P/N:52195. The user interface features are listed below: • Integral 80-character LCD display with backlighting. Notification Appliance and Releasing Circuit(s) - • Real-time clock/calendar with automatic daylight TB5 and TB7 savings adjustments. The notification appliance and releasing circuits for TB5 • ANN-Bus for connection to remote annunciators. and TB7 specifications are listed below. • Audible or silent walk test capabilities. Four Output Circuits. • Piezo sounder for alarm,trouble,and supervisory. Style Y(Class B)or Style Z(Class A)with optional converter module GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60467 Rev.D page 2 of 4 www.gamewell-fci.com Features (Continued) Product Line Information Notification Appliance and Releasing Circuit(s) - Product Description T135 and T137 (Continued) GF506R Six-zone, 24 volt Agent Release Control • Strobe synchronization Panel (includes backbox, power supply, • Special Application power technical manual, and a frame & post • Supervised and Class 2Power-Limited circuitry operating instruction sheet) for single Su p y and dual hazard agent releasing applica- • Normal Operating tions. Voltage: Nominal 24 VDC CAC-5X Class A Converter Module can be used • Maximum Signaling 7.0 amps(3.0 amps to convert the Style B (Class B) Initiating Current: maximum per NAC) Device Circuits to Style D (Class A) and • End-of-Line Resistor: 4.7KOhms, 1/2 watt Style Y(Class B)Output Circuits to Style (PN71252) Z(Class A). • Max.Wiring Voltage Note:Two(2), Class A Converter Modules are required to Drop: 2 VDC convert all four Output Circuits and six Initiating Device For a list of compatible devices,refer to the Gamewell-FCI Circuits. Device Compatibility Document, P/N:52195. 4XTMF Transmitter Module provides a super- vised output for the local energy munici- pal box transmitter and the alarm and Form-C Relays -Programmable -T138 trouble reverse polarity. It includes a dis- The Form-C Relays for TB8 specifications are listed below. able switch and disable trouble LED. • Relay 1 (factory default programmed as Alarm Relay). GFANN-80 LCD Annunciator is a remote LCD • Relay 2(factory default programmed as fail-safe annunciator that mimics the information Trouble Relay). displayed on the FACP LCD display.The recommended wire type is unshielded. • Relay 3(factory default programmed as Supervisory GFANN-LED Annunciator Module provides three Relay). LEDs for each zone: Alarm, Trouble and • Relay Contact Ratings: Supervisory. Ships with enclosure (red -2 amps @ 30 VDC(resistive) and black enclosures available; refer to -2 amps @ 30 VAC(resistive) P/N: DF-60241). GFANN-RLY Relay Module, which can be mounted Auxiliary Trouble Input—J6 inside or outside the cabinet,provides 10 p programmable Form-C relays. The Auxiliary Trouble Input is an open collector circuit DP-51050 Dress panel (red) is available as an which can be used to monitor external devices for trouble option. The dress panel restricts access conditions. It can be connected to the trouble bus of a to the system wiring while allowing peripheral, such as a power supply, which is compatible access to the membrane switch panel. with open collector circuits. TR-CE Trim-ring (red) is available as an option. The trim-ring allows semi-flushing Special Application Resettable Power-T139 mounting of the cabinet. The Special Application Resettable Power-TB9 BB-17F Battery box, holds up to two (2) 18 Amp specifications are listed below. Hour batteries and the CHG-75. • Operating Voltage: Nominal 24 VDC PRN-6 UL-Listed compatible event printer. Dot- Maximum Available Current:500 mA-appropriate for matrix,tractor-fed paper, 120 VAC. powering 4-wire smoke detectors(see note 1). PRT/PK Cable Programming cable. • Class 2 Power-Limited circuitry Used to update the FACPs Flash firm- For a list of compatible devices,refer to the Gamewell-FCI ware. (It also requires an RS485 to Device Compatibility Document, P/N:52195. RS232 converter). NOTE 1:Total current for resettable power, non-resettable power and Output Circuits must not exceed 7.0 amps. Special Application Resettable or Non-resettable Power-TB9 The Special Application Resettable or Non-resettable Power-TB9 specifications are listed below. • Operating Voltage: Nominal 24 VDC • Maximum Available Current: 500 mA(see Note 1) • Class 2 Power-Limited circuitry • Jumper selectable by JP31 for resettable or non-reset- table power. For a list of compatible devices,refer to the Gamewell-FCI Device Compatibility Document, P/N:52195. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60467 Rev.D page 3 of 4 J System Specifications System Specifications (Continued) System Capacity: Annunciators............8 Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0° Electrical Specifications —49°C/32° — 120°F and at a relative humidity 93% ± 2% Flex GF506R RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). How- (FLPS-7 Power Supply): 120 VAC,50/60 Hz, 2.3 amps ever, the useful life of the system's standby batteries and the electronic components may be adversely affected by Wire size: minimum 14 AWG(2.0 mm2) extreme temperature ranges and humidity. Therefore, it is with 600 V insulation, recommended that this system and its peripherals be supervised, non power-limited installed in an environment with a normal room tempera- ture of 15'—27°C/60°—80°F. Cabinet Specifications Door NFPA Standards Dimensions: 19.26"H x 16.82"W x 0.72" The Flex GF506R complies with the following NFPA Fire (48.92 Hx42.73 Wx 1.82 Dcm) Alarm Systems requirements: Backbox: 19.00"H x 16.65"W x 5.25"D -NFPA 12 CO2 Extinguishing Systems Dimensions: (48.26 Hx42.29 Wx 13.34 Dcm) (High Pressure Only) Trim Ring JR-CE): -NFPA 12A Halon 1301 Extinguishing Systems Dimensions: 22.00"high x 19.65"wide -NFPA 12B Halon 1211 Extinguishing Systems (55.88 Hx49.91 Wcm) -NFPA 72 National Fire Alarm and Signaling Code -NFPA 2001 Clean Agent Fire Extinguishing System Shipping Specifications -NFPA 2010 Standard for Fixed Aerosol Fire- Dimensions: Extinguishing Systems -Height 20.00"(50.80cm) -Width 22.50" (57.15cm) -Depth 8.50" (21.59cm) GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60467 Rev.D page 4 of 4 www.gamewell-fci.com INSTALLATION AND MAINTENANCE INSTRUCTIONS ��T�� 0. Selectable Output SENSOR' CD Horn Strobes, Chime Strobes 3825 Ohio Avenue,St.Charles,Illinois 60174 -6495 and Strobes - Ceiling Mount 800/736-7ww FAX: msens r.com www.systemsensor.com For use with the following models: Ceiling Mount Horn Strobes:PC2RL,PC2WL Ceiling Mount Chime Strobe CHSCWL Ceiling Mount Strobes:SCR SCWL, CWL-CLR-ALERT PRODUCT SPECIFICATIONS Standard Operating Temperature: 32°F to 120°F(0°C to 49°C) Humidity Range: 10 to 93%Non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage: Regulated 12VDC or regulated 24DC/FWR Operating Voltage Range: 8 to 17.5V(12V nominal)or 16 to 33V(24V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5V(12V nominal)or 16.5 to 33V(24V nominal) Input terminal wire gauge: 12 to 18 AWG DIMENSIONS FOR PRODUCTS AND ACCESSORIES MOUNTING BOX OPTIONS CEILING PRODUCTS Diameter Depth 2-Wire Indoor Products Strobe,Chime Strobe and Horn Strobe 6.83" 2.47" (173.5mm) (62.7mm) 4"x 4"x 11/2",Single Gang,Double Gang, Strobe,Chime Strobe,and Horn Strobe with 6.92" 2.50" 4"Octagon,SBBCRL/WL(ceiling) SBBCRL/WL Surface Mount Back Box (175.8mm) (63.5mm) NOTICE:This manual shall be left with the owner/user of this equipment. BEFORE INSTALLING produce temporal coded signals.Signals other than those used for evacuation Please read the System Sensor Audible Visible Application Reference Guide, purposes do not have to produce the temporal coded signal. System Sensor which provides detailed information on notification devices, wiring and recommends spacing notification appliances in compliance with NFPA 72. special applications.Copies of this manual are available from System Sensor. SYSTEM DESIGN NFPA 72 and NEMA guidelines should be observed. The system designer must make sure that the total current draw by the devices Important: The notification appliance used must be tested and maintained on the loop does not exceed the current capability of the panel supply,and following NFPA 72 requirements. that the last device on the circuit is operated within its rated voltage. The GENERAL DESCRIPTION current draw information for making these calculations can be found in the System Sensor series of notification appliances offer a wide range of audible tables within the manual.For convenience and accuracy,use the voltage drop and visible devices for life safety notification.Our 2-wire horn strobes,chime calculator on the System Sensor website(www.systemsensor.com). strobes and strobes come with 8 field selectable tone and volume combina- When calculating the voltage available to the last device, it is necessary to tions and 7 field selectable candela settings.Intended for indoor applications consider the voltage due to the resistance of the wire.The thicker the wire,the and approved for ceiling mount installations. smaller the voltage drop.Wire resistance tables can be obtained from electri- 2-wire horn strobes and strobes are public mode notification appliances in- cal handbooks.Note that if Class A wiring is installed,the wire length may tended to alert occupants of a life safety event. The 2-wire chime strobe is be up to twice as long as it would be for circuits that are not fault tolerant. a private mode notification appliance.The horn is listed to ANSI/UL 464 re- The total number of strobes on a single NAC must not exceed 69 for 24 volt quirements (public mode) and the strobe is listed to ANSI/UL 1638 (public applications. mode).2-wire chime strobe is a private mode notification appliances intended AVAILABLE TONES to alert trained personnel to investigate a life safety event and take appropriate System Sensor offers a wide variety of tones for your life safety needs,includ- actions.The chime portion of the chime strobe is listed to ANSI/UL 464(pri- ing temporal 3 pattern(1/2 second on,1/2 second off, 1/2 second on,1/2 second vate mode)and the strobe portion is listed to ANSI/UL 1638(private mode). off,1/2 second on,11/2 off and repeat)which is specified by ANSI and NFPA 72 System Sensor strobes are designed to be used in 12 VDC,24VDC,or 24V FWR for standard emergency evacuation signaling. (full wave rectified)systems.System Sensor AV devices can be activated by a To select the tone,turn the rotary switch on the back of the product to the compatible fire alarm control panel or power supply.Refer to the appropriate desired setting.(See Figure 1.)Available horn settings can be found in Table 1. fire alarm control panel manufacturer or power supply for more information. Available chime settings can be found in Table 2. System Sensor ceiling 2-wire horn strobes,2-wire chime strobes,and strobes AVAILABLE CANDELA SETTINGS are electrically backward compatible with the previous generation,since 1996, System Sensor offers a wide range of candela settings for your life safety of notification appliances. They come enabled with System Sensor synchro- needs. In order to select your candela output,adjust the slide switch on the nization protocol which requires connections to a power supply capable of rear of the product to the desired candela setting on the selector switch. (See generating the System Sensor synchronization pulses, a FACP NAC output Figure 2.) configured to System Sensor synchronization protocol, or the use of MDL3 module to generate the synchronization protocol. The candela setting can also be verified by looking into the small window on the front of the unit.See Table 3 for candela settings for ceiling products.All FIRE ALARM SYSTEM CONSIDERATIONS products meet the light output profiles specified in the appropriate UL Stan- The National Fire Alarm and Signaling Code,NFPA 72,requires that all noti- dards.(See Figures 3 to 5.) fication appliances,used for building evacuation installed after July 1, 1996, 1 I56-5846-002 10/02/2018 FIGURE 1.AUDIO SELECTOR FIGURE 2.CANDELA SELECTOR FIGURE 3.LIGHT OUTPUT-VERTICAL DISPERSION,CEILING TO WALLS L%UND 01ELEM TO FLOOR Percent of `E°'NC 4 WDELA 8ELE(T Degrees* i Rating 90 90. o ® 0 100 5-25 90 A0486-00 30-45 75 50 55 A0518.00 60 45 e e 0 TABLE 1.HORN TONES TABLE 2.CHIME TONES 65 35 Pos Tone Volume Volume 70 35 Pos Tone Setting Settin 75 30 1 Temporal High 1 1 Second Chime High 80 30 30 30 2 Temporal Low 2 1 Second Chime Low 85 25 3 Non-Temporal High 3 1/4 Second Chime High 90 25 25 20 5 ° 5 0 5 ° 5 20 25 FIUOR 4 Non-Temporal Low 4 1/4 Second Chime Low A0468-00 5 3.1 KHz High 5 Temporal Chime High Temporal FIGURE 4.LIGHT OUTPUT— FIGURE 5.VERTICAL 6 3.1 KHz Low 6 Temporal Chime Low HORIZONTAL DISPERSION DISPERSION,WALL TO FLOOR Temporal 3.1 KHz Degrees* Percent of Rating Degrees* Percent of Rating 7 Non-Temporal High 7 5 Second Whoop High 0 100 0 100 3.1 KHz 5-25 90 5-30 90 8 Non-Tem oral Low 8 5 Second Whoop Low 30-45 75 35 65 50 55 40 46 TABLE 3.CEILING-MOUNT STROBE CURRENT DRAW(mA) 55 45 45 34 8-17.5 60 40 50 27 Candela Volts 16-33 Volts 65 35 55 22 DC DC FWR 70 35 60 18 15 87 41 60 75 30 65 16 30 153 63 86 NOTE: Products set at 15 and 30 80 30 70 15 75 - 111 142 candela automatically work on 85 25 75 13 95 134 164 either 12V or 24V power supplies. 90 25 80 12 115 158 191 The products are not listed for Compound 45 24 85 12 150 189 228 12V DC operation when set to any to the left 177 226 264 other candela settings. Compound 45 24 90 12 CURRENT DRAW AND AUDIBILITY RATINGS to the right For the horn strobe,the current draw and audibility ratings for each setting is listed in Table 4.For the chime strobe,the current draw and audibility ratings for each setting is listed in Table 5.For the strobe,the current draw for each setting is listed in Table 3. A0467-00 00' 80 55 o a5 a0 35 30 A0469-00 *Tolerance of 1 degree is permitted. TABLE 4.CEILING--MOUNT HORN STROBE CURRENT DRAW(mA)AND SOUND OUTPUT(dBA) Current draw(mA) Sound Output(dBA) Pos Tone Volume 8-17.5 VDC 16-33 VDC 16-33 FWR 8-17.5 V 1633 V Setting 15 30 15 30 75 95 115 150 177 15 30 75 95 115 150 177 DC DC FWR 1 Temporal High 103 167 71 90 143 165 187 217 254 107 135 179 198 223 254 286 84 89 89 2 Temporal Low 96 165 54 71 137 161 185 211 249 78 101 151 172 199 229 262 75 83 83 3 Non-Temporal High 106 173 71 90 141 165 187 230 273 107 135 179 198 223 254 286 85 90 90 4 Non-Temporal Low 95 166 54 71 124 161 170 216 258 78 101 151 172 199 229 262 76 84 84 5 3.1 KHz High 111 164 69 94 147 163 184 229 257 108 135 179 200 225 255 289 83 88 88 Temporal 6 3.1 KHz Low 103 163 54 88 143 155 185 212 252 79 101 150 171 196 229 260 76 82 82 Tempera 7 3.1 KHz High 111 172 69 94 144 164 202 229 271 108 135 179 200 225 255 289 84 89 89 Non-Tem oral 8 3.1 KHz Non- Low 103 169 54 88 131 155 187 217 259 79 101 150 171 196 229 260 77 83 83 Temporal NOTE:Products set at 15 and 30 candela automatically work on either 12V or 24V power supplies.The products are not listed for 12VDC operation when set to any other candela settings. 2 I56-5846-002 10/02/2018 WIRING AND MOUNTING SHORTING SPRING FEATURE All wiring must be installed in compliance with the National Electric Code System Sensor notification appliances come with a shorting spring that is pro- and the local codes as well as the authority having jurisdiction.Wiring must vided between terminals 2 and 3 of the mounting plate to enable system con- not be of such length or wire size which would cause the notification appli- tinuity checks after the system has been wired,but prior to installation of the ance to operate outside of its published specifications.Improper connections final product. (See Figure 6.) This spring will automatically disengage when can prevent the system from alerting occupants in the event of an emergency. the product is installed,to enable supervision of the final system. Wire sizes up to 12 AWG(2.5 mmz)may be used with the mounting plate.The MOUNTING AND REMOVING APPLIANCE mounting plate ships with the terminals set for 12 AWG wiring. 1. Attach mounting plate to junction box using two of the provided Philips Make wire connections by stripping about 3/s'of insulation from the end of head screws.(See Figure 8.) the wire.Then slide the bare end of the wire under the appropriate clamping 2. Connect field wiring according to terminal designations. (See Figures 6 plate and tighten the clamping plate screw.We provide a wire strip guide.See and 7.) Figure 6 for wiring terminals and strip guide reference. 3. If the product is not to be installed at this point, use the protective dust ACAl1TION cover to prevent contamination of the wiring terminals on the mounting plate. Factory finish should not be altered:Do not paint! 4.To attach product to mounting plate: a.Remove the protective dust cover. ACAUTION b.Hook the tabs on the top of the product housing into the grooves on mount- Do not over tighten mounting plate screws; this may cause mounting plate ing plate. to flex. c.Pivot the product into position to engage the terminals on the mounting plate.Make sure that the tabs on the back of the product housing fully en- FIGURE 6.WIRING TERMINALS,SHORTING SPRING,AND STRIP GUIDE gage with the mounting plate. Shorting Spring d.Hold product in place with one hand,and secure product by tightening the single mounting screw in the front of the product housing. Ceiling Models only:To remove product from the mounting plate,loosen the captive mounting screw and press the locking button. FIGURE S.MOUNTING o ®® DTI WIRING TERMINALS 1.Negative(-).Line in and out 2.Positive(+).Line in and out m® 3.Positive(+).Line in and out Strip Guide A0475-01 SYSTEM WIRING The 2-wire horn strobe, chime strobe and strobe only require two wires for �m power and supervision. (See Figure 7.) Please consult your FACP manufac- �m ®® turer or power supply manufacturer for specific wiring configurations and special cases. FIGURE 7.2-WIRE CIRCUIT ° INPUT FROM OUTPUT A0492-01 FACP TO OR NEXT PRIOR o DEVICE DEVICE o o OR EOL Locking A0367-02 button A0574-00 TABLE 5.CEILING-MOUNT CHIME STROBE CURRENT DRAW(mA)AND SOUND OUTPUT(dBA) Current draw(mA) Sound Output(dBA) Pos Chime Tone Volume 8-17.5 VDC 16-33 VDC 16-33 FWR 8-17.5 V 16-33 V Setting 15 30 15 30 75 95 115 150 177 15 30 75 95 115 150 177 DC DC FWR 1 1 Second High 96 165 47 69 117 137 165 202 238 63 90 147 169 184 212 245 61 62 62 2 1 Second Low 93 162 47 68 116 137 165 200 238 63 88 147 169 183 212 244 56 55 55 3 1/4 Second High 94 161 48 70 117 138 166 202 237 65 90 149 170 184 213 246 67 70 70 4 1/4 Second Low 1 93 157 48 69 116 137 164 199 236 64 89 148 168 184 216 244 61 61 61 5 Temporal High 93 163 48 70 116 138 165 199 238 64 89 148 169 184 212 245 64 66 66 6 Temporal Low 92 160 1 47 1 69 116 136 164 198 237 63 88 147 169 1 183 212 245 59 60 60 7 5 Second High 98 169 54 77 124 146 173 206 245 75 100 155 178 193 221 255 76 78 78 Whoop 8 5 Second Low 95 166 49 71 117 144 168 202 239 68 91 148 170 186 217 248 62 64 64 Whoop NOTE:Products set at 15 and 30 candela automatically work on either 12V or 24V power supplies.The products are not listed for 12VDC operation when set to any other candela settings. 3 I56-5846-002 10/02/2018 TAMPER SCREW FIGURE 10.SURFACE MOUNTING ON CEILING For tamper resistance,the standard captive screw may be replaced with a Torx SBBCRUSBBCWL screw(sold separately). 1.To remove the captive screw,back out the screw and apply pressure to the back of the screw until it disengages from the housing. Replace with Torx ®® screw. (See Figure 9.) FIGURE 9.TAMPER SCREW IT15 Tom N6-2,5/S" SCREW-TMPR-50 A0494-02 A0493-01 FIGURE 11.CUT-OUTS FOR SPEAKER(SPK)AND STROBE(STR) INSTALLING A SURFACE MOUNT BACK BOX 1. The ceiling surface mount back box may be secured directly to the wall or ceiling. Use of grounding bracket with ground screw is optional. (See Figure 10.) STIR 2.The ceiling mount box can be used on ceiling horn strobe,chime strobe, STIR strobe as well as ceiling speaker and speaker strobe models.Use the STR cut- outs for ceiling horn strobe,chime strobe and strobe installation needs. (See A0495-00 Figure 11.) 3.Threaded knockout holes are provided for the sides of the box for a/4 inch and 1/2 inch conduit adapter. Knockout holes in the back of the box can be FIGURE 12.KNOCKOUT AND VS00/V700 REMOVAL FOR SURFACE used for a/4 inch and 1/2 inch rear entry. MOUNT BACK BOX 4.To remove the a/4 inch knockout,place the blade of a flat-head screwdriver Wire Mold Removal along the outer edge and work your way around the knockout as you strike the screwdriver. (See Figure 12.) 1/2 inch NOTE: Use caution not to strike the knockout near the top edge of the or a/4 inch surface mount back box. 5. V500 and V700 raceway knockouts are also provided. Use V500 for low o profile applications and V700 for high profile applications. Ao465-01 A0466-01 6.To remove the knockout,turn pliers up.(See Figure 12.) AWARNING THE LIMITATIONS OF HORN/STROBES The horn and/or strobe will not work without power.The horn/strobe gets its power The signal strobe may not be seen.The electronic visual warning signal uses an extremely from the fire/security panel monitoring the alarm system.If power is cut off for any rea- reliable xenon flash tube.It flashes at least once every second.The strobe must not be son,the horn/strobe will not provide the desired audio or visual warning. installed in direct sunlight or areas of high light intensity(over 60 foot candles)where the The horn may not be heard.The loudness of the horn meets (or exceeds) current visual flash might be disregarded or not seen.The strobe may not be seen by the visually Underwriters Laboratories'standards.However,the horn may not alert a sound sleeper or impaired. one who has recently used drugs or has been drinking alcoholic beverages.The horn may The signal strobe may cause seizures.Individuals who have positive photoic response to not be heard if it is placed on a different floor from the person in hazard or if placed too visual stimuli with seizures,such as persons with epilepsy,should avoid prolonged exposure far away to be heard over the ambient noise such as traffic,air conditioners,machinery to environments in which strobe signals,including this strobe,are activated. or music appliances that may prevent alert persons from hearing the alarm.The horn The signal strobe cannot operate from coded power supplies.Coded power supplies may not be heard by persons who are hearing impaired. produce interrupted power.The strobe must have an uninterrupted source of power in or- NOTE:Strobes must be powered continuously for horn operation. der to operate correctly.System Sensor recommends that the horn and signal strobe always be used in combination so that the risks from any of the above limitations are minimized. FCC STATEMENT System Sensor Strobes and Horn/Strobes have been tested and found to comply with the can radiate radio frequency energy and,if not installed and used in accordance with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules.These limits are instruction manual,may cause harmful interference to radio communications.Operation designed to provide reasonable protection against harmful interference when the equip- of this equipment in a residential area is likely to cause harmful interference in which ment is operated in a commercial environment. This equipment generates,uses,and case the user will be required to correct the interference at his own expense. SUPPLEMENTAL INFORMATION For the latest Warranty information,please go to: VRE2. http://www.Zstemsensor.com/en-us/Documents/E56-4000.pddf For Limitations of Fire Alarm Systems,please go to:htto://www.systemsensor.com/en-us/Documents/I56-1558.E ; Speakers only:For the latest Important Assembly Information,please go to: ❑� ❑� =�4. ❑� + http://www.ZLstemsensoLcom/en-us/Documents/IS6-6556.pd Warranty Limitations of Speakers Only: Fire Alarm Systems Assembly Information System Sensor®is a registered trademark of Honeywell International,Inc. 4 I56-5846-002 02018 System Sensor. 10/02/2018 SYSTEM SENSOR' Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications . 1 � System Sensor L-Series audible visible notification products are rich with features guaranteed to cut — I � installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02-12/01/2017-Page 3 L-Series Specifications Arch itect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02•1 2101/2 01 7•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(rnA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92'diam. 2.5' 6(17 3 mm)diam. (175.77 mm) (64 mm)� (17 peror PA. u sia c o Q o 41) C O O O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box O m ® � p � p0p a� 0000 �Op A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information DescriptionModel Ceiling Horn Strobes Ceiling Strobes 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL I 2-Wire,Horn Strobe,White SCWL Strobe,White 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©2017 System Sensor. corn SENSOR® Phone: Ohio Avenue•St.Charles,IL 7-649 Prorcurre current product Itest [nonce innofthisd ensheet. Phone:800 SENSOR2•Fax:630 377-6495 or currentproduct information,including th01/201version of this data sheet. AVDS86a-02•12/01/2017 n L-Series Gamewell © INSSTRUUME� Indoor Horns, Strobes, by Honeywell and Horn Strobes Description Indoor Selectable-Output Horns, The L-Series audible visible notification products offer the Strobes, and Horn Strobes for most versatile and easy-to-use line of horns, strobes, and Wall Applications horn strobes in the industry. In addition, this product includes lower current draws and a modern aesthetic design which reduce installation times and maximize prof- its. The following devices offer a variety of design options, so that the L-Series can be used for any application requirement. • White and red plastic housings. • Standard and small footprint devices. • Plain, FIRE, and FUEGO-printed devices. Similar to the entire L-Series product line, the wall-mount < horns, strobes, and horn strobes include a variety of fea- tures that increase their application versatility while simpli- fying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox.These fea- tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To further simplify the installation and protect devices from Wall Horns/Hom Strobes construction damage, the L-Series uses a mounting plate Features for all standard and compact models that include an on- board shorting spring. This feature allows Installers to test Listed for wall mounting only. wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide Offers small profile devices for horns and horn strobes. range of application requirements using the following fea- Provides an automatic selection of 12 or 24-volt tures: operation at 15 and 30 candela. • Field-selectable candela settings. Supports a rotary switch for horn tone and two volume • Automatic selection of 12-or 24-volt operation. selections. • Rotary switch for horn tones with two volume selections. Produces horn rated at 88+dBA at 16 volts. L-Series Specifications Uses field-selectable candela settings on wall units: Architect/Engineer Specifications - 15 -30 -75 -95 General - 110 - 135 - 185 The L-Series standard horns, strobes,and horn strobes Includes a mounting plate for all standard and all com- shall mount to any of the following enclosures: pact wall units. • standard 2 x 4 x 1 7/8-inch backbox Contains a mounting plate with a shorting spring that • standard 4 x 4 x 1 1/2-inch backbox checks the wiring continuity before device installation. • 4-inch octagon backbox Features a plug-in design with minimal intrusion into the • double-gang backbox backbox. The L-Series compact products shall mount to a single- Designed with a tamper-resistant construction. gang 2 x 4 x 1 7/8-inch backbox. A universal mounting Built with an updated modern design. plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting Supports electrical compatibility with the existing plate shall be used for mounting wall compact models. SpectrAlert and the SpectrAlert Advance products. The notification appliance circuit wiring shall terminate at Compatible with System Sensor synchronization protocol. the universal mounting plate. Also, the L-Series products, when used with the Sync-Circuit, Module accessory, shall SIGNALING - be powered from a non-coded notification appliance circuit ()� output and shall operate on a nominal 12 or 24 volts. rM LISTED APPROVED _ PENDING ISO 900I GAMEWELL-FCI 031 LI S NTY YISTIM� 12 Clintonville UURL Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for insta➢ation purposes,and are subject to change wnthout notice.Nb responsibility is assumed by Gamewell-FCI for their use. C2016byttoneyweu International Inc. A lights reserved www.gamewell-fci.com 9021-60929 Rev.A page 1 of L-Series Specifications (Continued) Physical/Electrical Specifications Architect/Engineer Specifications (Continued) General (Continued) Standard Operating When it is used with the Sync-Circuit Module,the following Temperature: 32°F to 120°F(0°C to 49°C) occur: Humidity Range: 10 to 93%non-condensing • 12-volt-rated notification appliance circuit outputs shall Strobe Flash Rate: 1 flash per second operate between 8.5 and 17.5 volts. Nominal Voltage: Regulated 12 DC or • 24-volt-rated notification appliance circuit outputs shall regulated 24 DC/FWR1 operate between 16.5 and 33 volts. Operating Voltage Range2: 8 to 17.5 V(12 V nominal)or The Indoor L-Series products shall operate between 32 16 to 33 V(24 V nominal) and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn Operating Voltage Range strobes shall have the following field-selectable candela (MDL3)Sync Module: 8 .5 to 33 V to 17 V(12 V nominal)or 16 settings: • 15 30 75 95 (24 V nominal) • 110 135 185 Input Terminal Wire Gauge: 12 to 18 AWG Strobe Wall-Mount Dimensions The strobe shall be an L-Series Model listed to (including lens): 5.6 L x 4.7 W x 1.25 D(143 UL Standard 1971 and shall be approved for fire protective nunLx119mmWx32mmD) service. The strobe shall be wired as a primary-signaling Compact Wall-Mount Dimensions: 5.26"L x 3.46"W x 1.93"D notification appliance and comply with the Americans with (including lens) (133mmL08rrnnWx49mmD) Disabilities Act requirements for visible signaling appli- Horn Dimensions: 5.6 L x 4.7 W x 1.25 D(143 ances, flashing at 1 Hz over the strobe's entire operating mmLx119mmWx32mmD) voltage range. The strobe light shall consist of a xenon Compact Horn flash tube and associated lens/reflector system. Dimensions: 5.25"L x 3.45"W x 1.25"D Horn Strobe Combination Notes: (133mm L x 88mm W x 32mm D) The horn strobe shall be an L-Series Model listed 1. Full Wave Rectified(FWR)voltage is a non-regulated, to UL Standard 1971 and UL Standard 464 and shall be time-varying power source that is used on some approved for fire protective service. The horn strobe shall power supply and panel outputs. be wired as a primary-signaling notification appliance and 2. P, S, PC,and SC products will operate at 12 V comply with the Americans with Disabilities Act require- nominal only for 15 cd and 30 cd. ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audible options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync-Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also,while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z(Class A)circuit.The module shall synchronize multiple zones. Daisy-chaining two or more synchroniza- tion modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 page 2 of 4 www.gamewell-fci.Com 9021-60929 Rev.A UL Current Draw Table 2 lists the UL maximum Horn current draw. Table 1 lists the UL maximum Strobe current draw. 8-17.5 8-17.5 Volts 16-33 Volts Sound Volts 16-33 Volts Candela DC DC FWR Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 Table 1: UL Maximum Strobe Current Draw(mA 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 RMS) 3.1 KHz Coded High 42 43 54 Table 2: UL Max. Horn Current Draw(mA RMS) UL Current Draw Data Table 3 lists the maximum UL Current Draw(mA RMS)allowed for 2-Wire Horn Strobes,candala range(15-115cd). 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 1156 153 173 1119 1140 1164 1190 1242 3.1 K Temp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1 k Cont Low 93 156 52 72 119 138 162 192 242 16V FWR FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 1 196 234 284 3.1 K Temp Low 68 90 145 166 186 1 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1 k Cont Low 77 102 1 156 177 199 234 1 291 Table 3: UL Max. Current Draw(mA RMS), 2-Wire Horn Strobe, Candela Range (15-115 cd) Horn Strobe Tones and Sound Output Data Table 4 lists the horn strobe tones and sound output data. 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 13.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 1 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Table 4: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA-Tel:(203)484-7161 -Fax:(203)484-7118 www.gamewell-fci.com 9021-60929 Rev.A page 3 of 4 L Series Dimensions L Series Dimensions 3A6 3.46 —1.25 1.25 6.2! 5.27 o1i �Ic 11111/1/111 fl--'+� 11111111111 11111111111 11111111111 I I�Ii 11 Figure 1 Compact Combo Figure 2 Compact Horn L Series Dimensions L Series Dimensions 4.70 4.70 1.91 1.91 1.25 1.25 & 7 5.67 f ' Figure 3 Standard Combo Figure 4 Standard Horn L-Series Ordering Information L-Series Ordering Information Wall Horn Strobes Horns Part Number Description Part Number Description P2RL 2-Wire, Standard Horn Strobe, Red HRL Standard Horn, Red P2WL 2-Wire, Standard Horn Strobe,White HWL Standard Horn,White P2GRL 2-Wire,Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Standard Horn Strobe,Red, Plain Accessories P2WL-P 2-Wire,Standard Horn Strobe,Wh ite,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Standard Horn Strobe,Red, TR-2W Universal Wall Trim Ring White FUEGO SBBRL Standard Wall Surface Mount Backbox, P2WL-SP 2-Wire, Standard Horn Strobe,White, Red FUEGO SBBWL Standard Wall Surface Mount Backbox, Wall Strobes White SRL Standard Strobe, Red SBBGRL Compact Wall Surface Mount Backbox, Red SWL Standard Strobe,White SGRL Compact Strobe, Red SBBGWL Compact Wall Surface Mount Backbox, White SGWL Compact Strobe,White Notes: SRL-P Standard Strobe, Red, Plain All-P models have a plain housing SWL-P Standard Strobe,White, Plain (no"FIRE"marking on cover). SRL-SP Standard Strobe, Red, FUEGO All-SP models have"FUEGO"marking on cover. SWL-CLR-ALERT Standard Strobe,White,ALERT All-ALERT models have"ALERT"marking on cover. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA-Tel:(203)484-7161 -Fax:(203)484-7118 page 4 of 4 www.gamewell-fci.com 9021-60929 Rev.A SYSTEM - �� SENSOR' �tll�tllt I'I'I'I'I oil F I I I I F ''t'''' Indoor Selectable- Output Horns R •, R , � Strobes ,, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut 46 •; - installation times and maximize profits with lower ` e' current draw and modern aesthetics. - Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications Arch itect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions 1.91' 3.46" 3.46" 48.5 mm 88 mm IIIIII��III�1.25' 3.57" 1.55" 88 mm 1.25' 32 mm (9.1 em) 3.9 cm) 32 mm I 0004001 W o 5.27„ °°rr°° 9°°°9°°°9°0°° 5.38' 133.9 mm 5.27" o°n°o°n°o°u°� (13.7 em) O 133.9 mm oao�nao�000ao nro�nro°n�o° C G� A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70' (11.94 cm) 1.91" 4.7" (4.85 cm) 1.25° 4.82„ 1.25" 119mm 32 mm (12.24 cm) (469 cm) (3.18 mm) 4 UP O ® O Zcm) 0 0 5.67" 0°0°0000°0578" O000.0 000 14( 144 mm °°°°°n0n0u0 0°0°0°0°04 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information DescriptionModel Description Model Wall Horn Strobes Horns* 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL I 2-Wire,Horn Strobe,White HWL* Horn,White ��2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SIP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St.Charles,IL 60174 ©2018SystemSensor SYSTEM . Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom SENSOR® www.systemsensor.com y for current product information,including the latest version of this data sheet. temsensor.com AVDS865-05.2/22/2018 SYSTEM SENSOR" Outdoor Selectable. , Output Horns, H Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products �► o v a iN c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151 oF. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill O '0, holes for screw-in mounting.Plastic and metal weatherproof back L F M MEA boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch 7300-1653:137(outdoor strobes) LISTED sao11(eniLIS,LISTED strobes,Hems) APPROVED approved 7125-1653:16s(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horn.,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40oF to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with ,8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams �4.7 5.6- ° O 0 Wall-Mount Horn Strobes ® ® Wall Plastic Weatherproof Back Box Red for exterior - RAI Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert)dvance Ordering Information DescriptionModel Wall Horn Stro es P2RK't 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK't 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK' 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RK 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK`t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK`t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK"t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02012 System Sensor Y S . rJI 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12 Honeywell I Addressable Devices QGamewell Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti°Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern brightwhite color,the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations.The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series°and S3 Series panels support both the Velociti°and CLIP"protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotaryaddress Includes dual LEDs for Offers expanded color Standard 268 7th functional test switch switches(01-159) 3601visibility options Edition activated by external magnet • Supplies optional relay, • Designed with a new isolator,or sounder profile to offer modern • Supports a low standby bases(standard or low and improved current frequency) aesthetics Ordering Information Ordering Information NOTE:"-IV"suffix indicates Ivory color model. Accessories NOTE:"-BL'suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. ASD-PL3:Photoelectric smoke detector,bright white, TR300:Accessory Flange Ring for B300 6"Base,bright Velociti white ASD-PL3R:Photoelectric smoke detector,remote test TR300-IV:Accessory Flange Ring for B300 6"Base,ivory capable,for use with DNR(W)ductsmoke detectors,bright RA10OZ: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with B501 and B300-6. sensinq,bri ht white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,refer to Data Sheet M02-04-01: Detectortest magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR2B: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high B501-WHITE: 4"Flangeless mounting base,brightwhite ceiling applications. B501-WHITE-BP:4"Flangeless mounting base bulk pack, XP-4: Extension pole for XR2B.Shipped with three,5-foot bright white (1.524,m)sections. B501-IV: 4°Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,brightwhite B300-6-IV:6"Flanged mounting base,ivory B300-6-BP:6"Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,brightwhite B200SR-IV:Standard sounder base,ivory B20OS-WH:Intelligent addressable sounder base,bright white B20OS-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, brightwhite B200SR-LF-IV:Standard low frequency sounder base, ivory B20OS-LF-WH:Intelligent addressable low frequency sounder base,bright white B20OS-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white B224BI-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti° Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Photoelectric Intelligent Detector: The Velociti°Series 3 Photoelectric Detectors are certifications,please visit: Physical Specifications designed to comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3Series®,Velociti°and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI®are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of Honeywell Operating Temperature Range: approval agencies,or listing may be in process. International Inc. Photo:320 F to 122'F(0'C to 501 C) Consult factory for latest listing status. UL°is a registered trademark Photo in Duct Applications:-4°F to 1581 F I S2332 of Underwriter's Laboratories (-20°C to 700 C) FM:3023594 Inc. Photo with Thermal:32'F to 1001 F(0'C to 38'C) M EA FDNY:COA-219-02-E Vol.VI This document is not intended Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to be used for installation non-condensing ISO 9001 Certification purposes.We try to keep our Rate-of-Rise Detection:Responds to greater than product information up-to- 15°F/minute or 135°F(8.3°C/minute or 57°C date and accurate.We cannot Range: 0 to 4,000 ft/min cover all specific applications Air Velocity 9 or anticipate all requirements. (0 to 1219.2 m/min) All specifications aresubjectto Electrical Specifications change without notice. Voltage Range: 15 to 32 VDC Standby Current(@ 24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA @ 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti®Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0617 1 K 104/2018 Honeywell www.honeywell.com ©2018 Honeywell International Inc. Honeywell I Addressable Devices QGamewell Velociti" Series 3 Detectors Thermal Detectors Description The Gamewell-FCI,Velociti°Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern bright white color,the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to beset with rotary address switches providing exact device locations.The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and Thermal Detector maintenance efficiency.Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 1350F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate-of-rise thermal detection. • ATD-1_3H provides fixed high-temperature detection at 190°F. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number that appears after the detector model. Note:The E3 Series°and S3 Series panels support both the Velociti°and CLIPI protocols,and the GWF-7075 panel supports onlythe Velociti°protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL°268 • Contains a built-in • Provides rotaryaddress • Includes dual LEDs Offers expanded color 7th Edition functional test switch switches(01-159) used for 3601 visibility options • Designed with a new activated by an • Supplies optional relay, profile to offer modern external magnet isolator,or sounder and improved • Supports a lowstandby bases(standard or low aesthetics current frequency) Ordering Information Ordering Information NOTE:'-IV"suffix indicates Ivory color model. Accessories NOTE:"-BL'suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. TR300:Accessory Flange Ring for B300 6"Base,bright ATD-1-3:Thermal heat detector,135°Ffixed,bright white, white velociti TR300-IV:Accessory Flange Ring for B300 6"Base,ivory ATD-L3-IV: hermal heat detector,135°F fixed,ivory, RA100Z:Remote LED annunciator,3-32 VDC e oci The annunciator mounts to a U.S.single-gang electrical ATD-L3R:Thermal heat detector,135°F rate of rise,bright box.For use with B501 and B300-6. white,Velociti CK300:Bright White detector kit(Pack of 10) ATD-L3R-IV: Thermal heat detector,135°F rate of rise, CK300-IR:White,detector color kit for use with MCS-COF ivory,Velociti/CLIP Series Detectors.(Pack of 10) ATD-1_311:Thermal heat detector,190°F high temp,bright CK300-IV:Ivory,detector color kit.(Pack of 10) elo V white, citi ATDe, elo V: Thermal heat detector,190°F high temp, CK300-IR-IV:Ivory,detector color kit for use with MCS- ivory,Velociti/CLIP COF Series detectors.(Pack of 10) CK300-BL:Black detector kit(Pack of 10) Intelligent Bases CK300-IR-BI:Black,detector color kit for use with MCS- For details on intelligent bases,refer to Data Sheet COF Series detectors.(Pack of 10) P/N:9021-60540. M02-04-01:Detector test magnet. B501-White: 4"Flangeless mounting base,bright white M02-09-00:Test magnet with telescoping handle. B501-White-BP:4"Flangeless mounting base bulk pack, XR2B:Detector removal tool.Allows the installation brightwhite and/or removal of the detector heads from the bases in B501-IV: 4"Flangeless mounting base,ivory high ceiling applications. B501-BL XP-4:Extension pole for XR2B.Shipped with three,5- 4"Flangeless mounting base, B300-6:6"Flanged mounting base,bright white foot(1.524,m)sections. B300-6-IV:6"Flanged mounting base,ivory B300-6-BP:6"Flanged mounting base bulk pack B200SR-WH:Standard sounder base,bright white B200SR-IV:Standard sounder base,ivory B20OS-WH:Intelligent addressable sounder base,bright white B20OS-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, bright white B200SR-LF-IV:Standard low frequency sounder base, ivory B20OS-LF-WH:Intelligent addressable low frequency sounder base,bright white B20OS-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white B224BI-IV: Isolator base,ivory 2 Velociti° Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Thermal Intelligent Detector The Velociti°Series 3 Thermal Detectors are designed to certifications,please visit: Physical Specifications comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.6 cm)installed in B300-6 base These listings and approvals apply to the modules E3 Series°,Velociti®and 4 inches(10.2 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI°are registered Shipping Weight: 3.4 oz(95 g) modules or applications may not be listed by certain trademarks and CLIP''is a Operating Temperature Range: approval agencies,or listing may be in process. trademark of Honeywell Thermal135"Ffixed:-41 Fto 1001 F Consult factory for latest listing status. International Inc. (-20°C to 38'C) UL:S2332 UL`is a registered trademark Thermal 135'F rate-of-rise:-4°F to 100'F FM:3023594 of Underwriter's Laboratories (-20°C to 38'C) MEA-FDNY:219-02-E Vol.A Inc. Thermal 190°F rate-of-rise:-41 F to 1351 F CSFM:7270-1703-0502 This document is not intended (-20°C to 57'C) ISO 9001 Certification to be used for installation Operating Humidity Range: 10%to 93%non- purposes.We tryto keep our condensing product information up-to- Rate-of-Rise Detection::Responds to greater than date and accurate.We cannot cover 15°F/minute or 135°F(8.3°C/minute or 57°C or anticipate specific applications or anticipate all requirements. Electrical Specifications All specifications aresubjectto Voltage Range::15 to 32 VDC change without notice. Standby Current(C 24 VDC): 200 uA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): :2 mA @ 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): :4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: :0.0063 For more information Learn more about Gamewell-FCI's Velociti°Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-06201 G 1 04/2018 Honmmell www.honeywell.com ©2018 Honeywell International Inc. KV Honeywell I Addressable Devices QGamewell MS-7 Series Manual Fire Alarm Pull Stations General The Gam ewe ll-FCI,MS-7 Series man ualfire alarm pull stations are available in a wide . variety of configurations.The pull stations comply with the Americans with Disabilities Act(ADA)5-lb.maximum pull force requirement.Operating instructions and Braille text are engraved in the handle.All pullstations include a key lock/resetwhich is keyed PUSH IN alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull PULL F�'SMVI stations. J, P U 01� 1 N MS-7AF elociti Addressable Station The MS-7AF Velociti`Series addressable station is a double action pull station J, designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the pull station causes its assigned address _ to register at the fire alarm control panel.The door contains an LED which flashes C green in normal condition and lights steady red when the station has been activated The station features screw terminals. MS-7 Series MS-7ASF Velociti Addressable Station The MS-7ASF Velociti®Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the station causes its assigned address to register at the control panel.The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.*The station features screw terminals. The Velociti®Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and focuses on the single device.The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels.It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations • The pull stations(MS- • Offers surface or semi- Includes a tumbler lock *Only the red LED is compatible with all 7LOB)are Listed for flush mounting fortest and reset keyed operative in panels that Gamewell-FCI analog outdoor applications alike with analog do not operate in Velociti addressable fire alarm • Shock and vibration addressable fire alarm mode controls • Complies with ADApull resistant controls force requirements • Conventional stations • Both single and double suitable for use with action pull stations any UL Listed control available panel MS-7S Single Action Station NYC-Plate The MS-7S single action pull station is used with The NYC-Plate provides the backplate for the manual conventional fire alarm control panels.It features a set pull station.(See Figure 1). of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station,with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities `L and Flex Series releasing systems.It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort Figure 1 NYC-Plate The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities Ordering Information and Flex Series releasing systems where system abort MS-7:Double action station capabilities are required.It consists of the following: MS-7AF**: elociti addressable double action station • An MS-7LR mounted on a plate with an abort switch MS-7ASF**:Velociti addressable single action station • LED indicators that signal system normal and MS-7S:Single action station,wire leads system activated status MS-7L0B Double Action Station(Listed for Outdoor MS-7SP:Double action station,English and Spanish Applications) instructions The MS-7LOB station must be mounted on a Model MS-7LR:Agent release station,dual-action SB-I/0 backbox.In retrofit applications,the pull MS-7LRA:Agent release station with abort switch, station is UL Listed for use with the WP-10 backbox.It LED indicators,dual-action is intended for use with conventional control panels MS-7L0B:Double action station,outdoor use and has a set of single pole contacts and screw (Includes SB-1/0-Indoor/outdoor use backbox) terminals. SB-I/O:Indoor/outdoor use backbackbox Mounting The MS-7 interior pull stations may be surface SB-10:Surface backbox mounted or semi-flush mounted on a standard BG12TR:Trim ring for semi-flush mount,plastic double-gang,or4-inch(10.2 cm)square electrical box. NY-PLATE:NYC backplate for manual pull station An optional trim ring(BG12TR)may also be used for semi-flush mounting. **For use with the Gamewell-FCI analog addressable control panels only. 2 MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all The MS-7 Series is designed to com wth the following compliance approvals and li h lli Material:Lexan° g p y g certifications,please visit: Contact Ratings:0.25 amps.C 30 VAC/VDC(resistive) standard: http://www.gamewell- Dimensions:5 5/8"H x 41/4"W x 1 1/4"D UL Standard:UL 864 9th Edition fci.com/en-US/ (14x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx 0 eratin Temperature: These listings and approvals apply to the modules LEXAN°is a registered MS-7AF,MS-7ASR 32o to 1200 F Moto 490 C) specified in this document.In some cases,certain trademark of GE Plastics,a (MS-7LOB):-30°to 150°F(-35°to 66°C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies,or listing may be in process. Company. UL:S2465 MS-7AF, S-7ASF):10to93%(non-condensing) Consult factory for latest listing status. Velociti°and Gamewell-FCI ):85% 5%C�86° 3.6°(30° 2°C) are registered trademarks of Alarm Current:.0030 amp.0.007 for LED FM:3023594 Honeywell International Inc. Supervisor Current: MEA FDNY:67-02-E Vol.VI . Y UL`is a registered trademark (MS-7AF,MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. This system meets NFPA requirements for operation at 0 7160-1703:0170 This document is not intended —49°C/32—120°F and at a relative humidity 93% 2% 7160-1703:0109 to be used for installation RH(noncondensing)at 32°C 2°C(90°F 3°F). ISO 9001 Certification purposes.We tryto keep our However,the useful life of the system's standby batteries product information up-to- and the electronic components may be adversely affected date and accurate.We cannot cover all specific applications by extreme temperature ranges and humidity. Therefore, or anticipate all requirements. it is recommended thatthis system and its peripherals be All specifications are subjectto installed in an environment with a normal room change without notice. temperature of 15—27°C/60—80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 H o n eywe I I www.honeywell.com ©2017 Honeywell International Inc. ­44q Honeywell I Addressable Devices QGameuvell Velociti Series°,AOM-20, Addressable Output Relay Control Module General The Gamewell-FCI Velociti®Series,addressable output relay control module(AOM- 2RF)allows a Gamewell-FCI analog addressable fire alarm control panel to switch <Y - discrete relay contacts by code command.The relay provides two isolated sets of Form-C contacts which transfer simultaneously.Circuit connections to the relay — — contacts are not supervised by the module. The Velociti'Series use a communication protocol that substantially increases the — speed of communication between the SLC devices and certain Gamewell-FCI analog ill "I addressable fire alarm control panels.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and concentrates on the single device.The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any AOM-2RF Gamewell-FCI analog addressable fire alarm control panel.The module contains a panel controlled LED.The AOM-2RF is designed to mount in a 4"(10.16 cm)square junction box 21/8"(5.53 cm)deep. Ordering Information AOM-2RF:Addressable output relay control module Table 1 lists the relay contact ratings. CURRENT MAXIMUM LOAD RATING VOLTAGE DESCRIPTION APPLICATION 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30VDC Inductive Coded (L/R=5ms) 1A 30VDC Inductive Coded (L/R=2ms) 0.5A 125 VAC Inductive Non-Coded (PF=.35) 0.7A 75VAC Inductive Non-Coded Table 1:Relay Contact Ratings FEATURES & BENEFITS • Listed under UL Provides visual rotary, Includes a bi-color LED Designed as a compact Note 1:Only the red LED Standard 864 decimal switch that flashes green size to allow easy is operative in panels that addressing(01-159) wheneverthe module is installation do not operate in Velociti • Offers two sets of Form addressed,and lights mode "C"contacts stead red upon p on *Note 2:Thebi-color LED activation* functionality is not available on the GWF-7075 panel. Velociti Series° AOM-2RF Technical Specifications SYSTEMS STANDARDS For a complete listing of all The Velociti Series°AOM-2RF is designed to l with compliance approvals and comply Supervisory Current:.000375 amps. g p y certifications,please visit: Alarm Current:.0065 amps. the following standard: http://www.gamewell- Operating Temperature:320 to 1200 F Moto 49'C) UL Standard:UL 864 9th Edition fci.com/en-US/ o AGENCY LISTINGS AND APPROVALS documentation/Pages/ Relative Humidity:l0 to 93/o relative humidity(non- Listings.aspx condensing) These listings and approvals apply to the modules Dimensions:41/2"H x 4"W x 1 1/4" Velocitil Series and Gamewell- specified in this document.In some cases,certain FCI®are registered trademarks (11.4 x 10.2 x 3.2 cm) modules or applications may not be listed by certain of Honeywell International Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies,or listing may be in process.Consult factory for latest listing status. UL®is a registered trademark This system meets NFPA requirements for operation at 0 of Underwriter's Laboratories —49°C/32-120°F and ata relative humidity 93% 2% UL:S1913 Inc. RH(noncondensing)at 32oC 20C(90OF 30F). FM:3023594 However,the useful life of the system's standby batteries MEA FDNY:219-02-E Vol.VI This document is not intended and the electronic components may be adversely affected CSFM:7300-1703:0102 to be used for installation by extreme temperature ranges and humidity. Therefore, purposes.We tryto keep our ISO 9001 Certification product information it is recommended thatthis system and its peripherals be installed in an environment with a normal room date and accurate.Wee cannot coverall specific applications temperature of 15—271C/60—801F. or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's Velociti Series°AOM-2RF and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0625 I H 108/18 H o n eywe I I www.honeywell.com ©2018 Honeywell international Inc. ' Functional RIB® !, ll� Devices, �nE. � (800)888-5538 sales(afunctionaldevices.com ® www.functionaidevices.com DRY CONTACT INPUT RELAY RIB01 BDOmp SPDT,Class 2 Dry R1801 B D C [air yl)RIR S C U� BS Contact Input,120 Vac Power Input .. M..�� E 1& LISTED Z—m. roa,.M C E AAUeN mq Org DAIAsIiG rmmn N/O gAM�nn4rAVx n.i ;. ieemx"`c 'u�1 IIIIRf 1 120 VacWht uwn��M�n>k 'r RoXB Yel l CONTROL Neutra C CIRCUIT 1ii11= Blu N/C Dry Contact Input Wht/Red Wht/Blu SPECIFICATIONS #Relays&Contact Type: One(1)SPDT Continuous Duty Coil Contact Ratings: Power Input: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 277 Vac 42 mA @ 120 Vac Operating Temperature: -30 to 140'F 1110 VA Pilot Duty @ 277 Vac Humidity Range: 5 to 95%(noncondensing) 770 VA Pilot Duty @ 120 Vac Operate Time: 1.8 Seconds 20 Amp Ballast @ 277 Vac Notes: Relay Status: LED On=Activated 16 Amp Electronic Ballast @ 277 Vac(N/O) •Dry Contact Input Operation: Dimensions: 2.30-x 3.20-x 1.80-with.50-NPT Nipple 10AmpTungsten @ 120Vac(N/O) Close White/Red wire to White/Blue wire to Wires: 16-,600V Rated 240 WattTungsten @ 120 Vac(N/Q activate relay.If more than one dry contact Approvals: UL Listed,UL916,C-UL,CE,ROHS 2 HP @ 277 Vac RIB®shares a single dry contact input, Housing Rating: UL Accepted for Use in Plenum,NEMA 1 1 HP @ 120Vac White/Blue must be common. Gold Flash: No Override Switch: No 20191121 Functional Functional Devices,Inc. Toll-free: (800)888-5538 Email: sates@functionaldevices.com RIB 101 Commerce Drive Office: (765) 883-5538 Website: www.functionaldevices.com Devices,Inc: Sharpsville,IN 46068 Fax: (765) 883-7505 TERMS AND CONDITIONS OF SALE 1. OFFER,GOVERNING PROVISIONS AND CANCELLATIONS:This document constitutes an offer or counter-offer that such Product was originally defective,then Seller will at its option repair or replace the product without by Functional Devices,Inc.or any of its affiliates("Seller")to sell various products as agreed by Seller("Products") charge upon prepaid delivery of such Product to Seller's facility with proof of date of purchase.Corrections to the buyer named on the reverse side ofthis document or in other applicable print or electronic documentation of such defects by repair to or supplying of replacements for defective parts shall constitute fulfillment of all ("Buyer")in accordance with these terms and conditions.This writing is not an acceptance of any offer made by obligations of Seller. Buyer.This offer or counter-offer is expressly conditioned upon Buyer's assent to these terms and conditions and no others.Buyer is deemed to have assented to these terms and conditions(including Seller's warranty)when the first Seller shall not be liable for loss,damage,or expense directly or indirectly caused from the failure of Products to ofthe following occurs:A.Buyer signs and delivers to Seller an acknowledgement copy of any of Seller's quotation, perform as expected. order acknowledgement or invoice forms;B.Buyer gives to Seller(orally or in writing)specifications of quantity and/ or type,assortments thereof,delivery dates,shipping instructions,instructions to bill,or the like as to all or any part EXCEPT AS SET FORTH HEREIN,SELLER DISCLAIMS ALL REPRESENTATIONS OR WARRANTIES OF ANY KIND ofthe Products;C.Buyer receives delivery of any of the Products;or,D.Buyer has otherwise assented to the terms WHATSOEVER,WHETHER EXPRESS,IMPLIED OR STATUTORY,INCLUDING,WITHOUT LIMITATION,ANY IMPLIED and conditions hereof. WARRANTIES OF MERCHANTABILITY,NON-INFRINGEMENT,FITNESS FOR A PARTICULAR PURPOSE OR ANY WAR- RANTY ARISI NG FROM A COURSE OF DEALING OR USAGE OF TRADE.NO PERSON(INCLUDING ANY AGENT,DEALER Where an attachment to this Agreement or separate document referencing this Agreement consists of a quotation, OR REPRESENTATIVE OF SELLER)IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTYCONCERNING the quotation remains open for acceptance for a period of thirty(30)days or such other period as specified in the PRODUCTS EXCEPT TO REFER BUYER TOTHIS AGREEMENT.BUYER WARRANTS THAT BUYER HAS NOT RELIED ON quotation.Seller hereby rejects any additional or different terms or provisions contained in any purchase order, ANY OTHER WARRANTIES OR REPRESENTATIONS CONCERN ING THE PRODUCTS OR THIS AGREEMENT. acknowledgment or other communication heretofore or hereafter received from Buyer.Seller's delivery of Products For warranty service,call factory for RA number and send such Product prepared with sales receipt to: does not constitute an assent to any terms proposed by Buyer.Except for an officer of Sel ler,no representative of FUNCTIONAL DEVICES,INC.,101 COMMERCE DRIVE,SHARPSVILLE,IN 46068. Seller has any authority to waive,alter,vary,amend,or add to the terms hereof.THESE TERMS AND CONDITIONS OF SALE CONSTITUTE THE ENTIRE AGREEMENT rAGREEMENT")BETWEEN SELLERAND BUYER WITH RESPECT 7, LIMITATION OF LIABILITY:SELLER WILL NOT BE LIABLE FOR ANY LOSS OF PROFIT,INTERRUPTION TO THE MATTERS ADDRESSED HEREIN. OF BUSINESS OR ANY OTHER SPECIAL,CONSEQUENTIAL OR INCIDENTAL DAMAGES SUFFERED OR SUSTAINED BY BUYER FOR ANY REASON.EXCEPT FOR CLAIMS OF DEATH OR PERSONAL INJURY,IN NO 2. PRICES:The prices for the Products are based on the terms and conditions herein,including the limitations of EVENT WILL SELLER'S AGGREGATE LIABILITY TO BUYER ARISING UNDER ORIN ANYWAY RELATED TO liability and warranties,and all such terms and conditions are material to the sale of the Products.In the event Seller THIS AGREEMENT FOR ANY REASON(INCLUDING,BUT NOT LIMITED TO,LIABILITY ARISING FROM NEG- fails to provide a price quote and/or terms prior to the acceptance ofthe order,Buyer will pay Seller's then-current list LIGENCE OR ON THE BASIS OF STRICT LIABILITY,OR OTHERWISE)EXCEED THE TOTALAMOUNT PAID BY price for such Products.All quotations and invoices show the net selling price of each item quoted.In the event ofa BUYER TO SELLER HEREUNDER FOR ANY PRODUCT GIVING RISE TO A CLAIM UNDER THIS AGREEMENT. mathematical error,the quoted price per Product governs. 8. RETURNS:Unless otherwise approved by Seller in writing in its sole discretion,except in the case of a 3. TERMS OF PAYMENT:Buyer will pay the fees specified in each invoice provided by Seller in United States non-conforming shipment or a warranty issue,Buyer may not return Products.If Seller approves the return of Dollars within thirty(30)calendar days after the invoice date unless otherwise agreed to in writing by an authorized Products pursuant to the preceding sentence,such returned Products must be returned within ninety(90)days representative of Seller.Any amount due under this Agreement that remains unpaid after its due date will bear from date of invoice and will be subject to a 25%restocking fee.In the event of a non-conforming shipment or interest from the date that such payment became delinquent until the date it is paid in full at the lower of 1.5%per a warranty issue,Buyer may return Products,but only if Buyer first:(a)provides notice to Seller as required in month,which equals an annual percentage rate of 18%,or the maximum rate permitted bylaw.Seller reserves the this Agreement,(b)obtains prior authorization from Seller,and(c)all Products or containers for which return is right to establish,revoke or modify credit terms for Buyer at anytime.No discounts are allowed unless otherwise properly authorized have been marked with a return authorization number supplied by Seller.Buyer will make agreed to in writing by an authorized representative of Seller.Buyer will pay any collection fees,legal fees,or court all returns via a traceable form such as Federal Express,UPS or insured mail and in resalable condition.Buyer costs incurred by Seller to collect past due amounts.No offsets or setoffs of payments due to Seller hereunder are will pay all return shipping charges and any other charges associated therewith. allowed with respect to any other agreement between the parties.Seller hereby retains a lien on the goods sold for unpaid purchase money as herein provided. 9. CANCELLATIONS:Cancellation or deferment of all or part of an order is subject to acceptance by the Seller. If accepted,any reduction in quantity of any item to less than 85%ofthe original item quantity is subject to 4. TAXES AND OTHER CHARGES:In addition to the prices quoted or invoiced,Buyer will pay any sales tax,excise a 15%cancellation charge.If an order cancellation is accepted,the Buyer will make delivery and pay for all tax,use tax,value added or consumption tax,customs duty(that is assessed on the delivery of Product(s)to a material manufactured and in stock or in process at time of notice for such order,and for any special materials destination outside ofthe U.S.A.),fee or charge of any nature whatsoever imposed by any governmental authority on orders for which the Seller must take delivery. on or measured by the transaction between Seller and Buyer.In the event Seller is required to pay any amount,Buyer will reimburse Seller therefore;or provide Seller,at the time the order is submitted,an exemption certificate or other 10. EXPORTS.Buyer agrees that it will comply with any and all U.S.Export Controls and will not pay for,resell, document acceptable to the authority imposing the same.Seller does not accept and will not pay any fines,penalties transfer or knowingly sell Products in violation of U.S.Export Controls.If Buyer resells Products within or exports or chargebacks from Buyer for any reason. Products to a country or region which imposes upon Seller and/or Buyer an obligation to fund or undertake reuse,recycling,composting,recovery of Products,or any similar obligation(e.g.,the European Union's Waste 5. DELIVERY,RISK OF LOSS,CLAIMS AND FORCE MAJEURE: Electrical and Electronic Equipment Directive,EC 2002/96/EC)(the"Obligations"),Buyer shall wholly under- A.All prices quoted for products are Ex-Works(Incoterms 2010)at a shipping facility determined by Seller,unless take the Obligations or duties and shall be entirely responsible for all associated costs therewith.Seller shall otherwise noted by Seller("Seller''sShipping Facility").Risk of loss or damage,and beneficial ownership,ofthe have no obligation to reimburse Buyer for execution ofthe Obligations.In the eventthat Seller is named in a Products are transferred to Buyer when the Products are made available to Buyer at Seller's Shipping Facility.All proceeding based upon the Obligations,Buyer shall indemnify,defend and hold Seller harmless from all actions delivery dates are approximate. related thereto,including all civil and governmental actions. B.Buyer will only make written claims to Seller for damages,shortages or other delivery errors within seven(7) 11. MISCELLANEOUS.This Agreement is governed by the laws of the State of Indiana,without giving effect calendar days after receipt of shipment.All Products received by Buyer,or Buyer's clients,customers,or agents,that to its conflict of laws principles.Buyer hereby irrevocably consents and submits to the exclusive jurisdiction and are not rejected within such time will be deemed accepted.Failure to provide such written notice constitutes a waiver venue of the state and federal courts in Marion County,Indiana.The United Nations Convention for Contracts of all such claims regarding such shipment by Buyer.Buyer will not revoke acceptance. for the International Sale of Goods is explicitly excluded.Each provision contained in this Agreement constitutes (.Seller is not liable for any damage as a result of any delay or failure to deliver due to any act of God,act of a separate and distinct provision severable from all other provisions.If any provision(or any part thereof)is Buyer,embargo or other governmental act,regulation or request,fire,accident,power outage,strike,civil unrest, unenforceable under or prohibited by any present orfuture law,then such provision(or part thereof)will be weather,slowdown or other labor difficulties,war,riot,act ofterrorism,delay in transportation,defaults of common amended,and is hereby amended,so as to be in compliance with such law,while preserving to the maximum carriers,inability to obtain necessary labor,materials or manufacturing facilities or,without limiting the foregoing, extent possible the intent ofthe original provision.Any provision(or part thereof)that cannot be so amended any other delays beyond Seller's control.Buyer's sole and exclusive remedy for any delays or for Seller's inability will be severed from this Agreement;and,all the remaining provisions ofthis Agreement will remain unim- to deliver Products for any reason,in each case,that persists for more than ninety(90)days,is to cancel the order paired.No modification,addition or deletion,or waiver of any rights under this Agreement is binding on a party pursuant to Seller's Order Policies and Guidelines available upon request. unless made in a non-preprinted agreement clearly understood by the parties to be a modification or waiver, and signed by a duly authorized representative of each party. 6. WARRANTY;DISCLAIMER.Products are warranted to be free from manufacturing defects under normal use and conditions for five(5)years(the"Warranty Period"). The warranty does not apply to:(a)Damage caused by accident,abuse,mishandling,or dropping;(b)Products which have been subjected to unauthorized repair,opened,or taken apart;(c)Products not used in accordance with direc- tions;(d)Damages exceeding the cost of such Product;and(e)Damages caused by lightning,water,or condensation. lfwarranty service is required during the Warranty Period,and ifexamination shall disclose to Seller's satisfaction F2700 2.1.2020 � - -p _ Gameweii Velociti Series - FIRE CONTROL INSTRUMENTS AMM- by Honeywell Description Addressable Monitor Module The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit(IDC)with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- - — - -- _ tacts may be made addressable when connected to the AMM-2F module. AM42F The Velociti® Series use a communication protocol that substantially increases the speed of communi- Features cation between the sensors and certain Gamewell- Compact size allows easy installation FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the Class B, Style B, initiating circuit devices in the group has a status change, the 40 Ohm line resistance for each initiating device circuit panel's microprocessor stops the group poll and Connects to any normally open dry contact device concentrates on the single device. The net effect is response speed up to five times greater than earlier Specifications designs. Supervisory Current: .000375 amps The AMM-2F module can be programmed to provide Alarm Current: .00060 amps a wide variety of input functions to the Gamewell-FCI Operating Temperature: 32'to 120' F (0'to 49' C) addressable series fire alarm control panels. It can Relative Humidity: 10 to 93% be identified as a manual station, heat detector, ple- (non-condensing) num detector, waterflow switch, tamper switch, N.O. End-of-Line Resistance:47K ohms contact, smoke detector, projected beam smoke Dimensions: 1.YLx2.5"Wx0.5"D detector, sub loop, remote zone, etc. It can also (3.3 x6.4 x 1.3 cm) serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- Ordering Information ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- Part Number Description port a maximum line resistance of up to 40 ohms AMM-2F Addressable monitor module,single allowing the use of linear heat detection devices. The circuit,Style B, Class B compact size facilitates the installation of the module inside manual stations, or mounting boxes of various An ISO 9001-2000 Company types of alarm initiating devices. SIGNALINGO FM N,: Velocih'V is a registered trademark of Honeywell International Ina �� INI EA UL®is a registered trademark of Underwriters laboratories Inc. - '-- LISTED APPROVED Approved S1949 3023594 227-03-EVOLIV 7300-1703:102 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.Nb responsibility is assumed by Gamewell-FCI for their use. G2011 FloneywwU International Inc. Allrightsreserved. www.gamewell-fci.com 9020-0626 Rev.D1 page 1 of 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS Honeywell Velociti® Series 3 � QGamewell ©INSIRVM�rS� ASD-PL3R and ASD-PL3R-IV 12 Clintonville Road Intelligent Photoelectric Smoke Sensor Northford,CT 06472-1653 Phone:203.484.7161;Fax:203.484.7118 with Remote Test Capability in Duct Applications www.gamewell-fci.com SPECIFICATIONS Operating Voltage Range: 15 to 32 VDC Operating Current @ 24 VDC: 200 uA(one communication every 5 seconds with green LED blink on communication) Maximum Alarm Current: 2 mA @ 24 VDC(one communication every 5 seconds with red LED solid on) Maximum Current: 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED solid on) Operating Humidity Range: 10%to 93%Relative Humidity,Non-condensing Operating Temperature Range: 320F to 1220F(0°C to 50°C),-4°F to 158°F(-20oC to 70°C)in duct applications Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.) Height: 2.0"(51 min)installed in B300-6 Base Diameter: 6.1-(155 min)installed in B300-6 Base;4.1"(104 min)installed in B501 Base Weight: 5.2 oz. (147 g) Isolator Load Rating: 0.0063* *Please refer to your isolator base/module manual for isolator calculation instructions. UL268A listed for Duct Applications Duct Applications: ASD-PL3R and ASD-PL3R-IV are listed for use in ducts. This sensor must be installed in compliance with the control panel system See Duct Smoke Detectors Applications Guide HVAG53 for details on pendant installation manual. The installation must meet the requirements of the Au- mount applications.NOTE:ASD-PL3R and ASD-PL3R-IV are also listed for use thority Having Jurisdiction(AHJ).Sensors offer maximum performance when inside DNR(W)duct smoke detectors. installed in compliance with the National Fire Protection Association(NFPA); WIRING GUIDE see NFPA 72. All wiring must be installed in compliance with the National Electrical Code, GENERAL DESCRIPTION applicable local codes,and any special requirements of the Authority Having Models ASD-PL3R and ASD-PL3R-IV are plug-in type smoke sensors that com- Jurisdiction.Proper wire gauges should be used.The installation wires should bines a photoelectronic sensing chamber with addressable-analog communi- be color-coded to limit wiring mistakes and ease system troubleshooting.Im- cations.When used in duct applications with a DNR(W),testing can be done proper connections will prevent a system from responding properly in the remotely using approved System Sensor test accessories,eliminating the need event of a fire. for a test coil.The sensors transmit an analog representation of smoke density Remove power from the communication line before installing sensors. over a communication line to a control panel. Rotary dial switches are pro- 1. Wire the sensor base(supplied separately)per the wiring diagram,Figure 2. vided for setting the sensor's address. 2. Set the desired address on the sensor address switches,see Figure 1. FIGURE 1.ROTARY ADDRESS SWITCHES: 3. Install the sensor into the sensor base.Push the sensor into the base while turning it clockwise to secure it in place. S5 6 7$ 94. After all sensors have been installed,apply power to the control panel and 4activate the communication line. 25. Test the sensor(s)as described in the TESTING section of this manual. 1 0 TENS ONES C0162-00 ACAl1TION Two LEDs on the sensor are controlled by the panel to indicate sensor status. Dust covers provide limited protection against airborne dust particles during An output is provided for connection to an optional remote LED annunciator shipping.Dust covers must be removed before the sensors can sense smoke. (P/N RA100Z). Remove sensors prior to heavy remodeling or construction. Note: Only System Sensor approved accessories may be used with the ASD-PL3R and ASD-PL3R-IV. FIGURE 2.WIRING DIAGRAM: Gamewell-FCI panels offer different features sets across different models.As a Remote CAUTION:Do not loop wire under result,certain features of the photoelectric sensors may be available on some Annunciator terminal 1 or 2. Break wire run to control panels,but not on others.ASD-PL3R will support only Velociti®Series supervise connections. protocol mode.ASD-PL3R-IV will support either Velociti or CLIP(Classic Loop Interface Protocol) mode.The possible features available if supported by the (+) control panel are: I I 1. The sensor's LEDs can operate in three ways—on,off,and blinking-and E m ++_ ++_ +� they can be set to red,green,or amber.This is controlled by the panel. ® �a ® ® �s 2. The remote output may be synchronized to the LED operation or con- 0 ®® I®® I trolled independent of the LEDs. N 0 3. Devices are point addressable up to 159 addresses. (-) I I Please refer to the operation manual for the UL listed control panel for specific ———————— -—————————— —_—_—_____p p p (-) ——— CLASS A OPTIONAL WIRING_ I operation. The ASD-PL3R and ASD-PL3R-IV require compatible addressable (+) —� C0129-10 communications to function properly.Connect these sensors to listed-compat- TAMPER-RESISTANCE ible control panels only. Models ASD-PL3R and ASD-PL3R-IV include atamper-resistant capability that SPACING prevents their removal from the base without the use of a tool. Refer to the Gamewell-FCI recommends spacing sensors in compliance with NFPA 72.In base manual for details on making use of this capability. low air flow applications with smooth ceilings, space sensors 30 feet apart TESTING (9.1 m). For specific information regarding sensor spacing, placement, and special applications,refer to NFPA 72 or the System Smoke Detector Applica- Before testing, notify the proper authorities that the system is undergoing tion Guide,available from Gamewell-FCI. maintenance, and will temporarily be out of service. Disable the system to prevent unwanted alarms. 1 I56-6536-001 09/23/2019 All sensors must be tested after installation and periodically thereafter.Test- S. Use a vacuum cleaner or compressed air to remove dust and debris from ing methods must satisfy the Authority Having Jurisdiction (AHJ). Sensors the sensing chamber. offer maximum performance when tested and maintained in compliance with 6. Reinstall the chamber cover/screen assembly by sliding the edge over the NFPA 72. sensing chamber.Turn until it is firmly in place. The sensor can be tested in the following ways: 7. Replace the cover using the LEDs to align the cover and then gently push- A. Functional:Magnet Test(P/N M02-04-01 or M02-09-00) ing it until it locks into place. This sensor can be functionally tested with a test magnet.The test magnet 8. Reinstall the detector. electronically simulates smoke in the sensing chamber,testing the sensor 9• Test the detector as described in TESTING. electronics and connections to the control panel. 10.Reconnect disabled circuits. 1. Hold the test magnet in the magnet test area as shown in Figure 3. ll. Notify the proper authorities that the system is back on line. 2. The sensor should alarm the panel. SPECIAL NOTE REGARDING SMOKE DETECTOR GUARDS TWo LEDs on the sensor are controlled by the panel to indicate sensor Smoke detectors are not to be used with detector guards unless the combina- status.Coded signals,transmitted from the panel,can cause the LEDs to tion has been evaluated and found suitable for that purpose. blink,latch on,or latch off.Refer to the control panel technical documen- FIGURE 3:FEATURES OF THE PHOTO DETECTOR tation for sensor LED status operation and expected delay to alarm. B. Smoke Entry Magnet Test\Sensitivity readings are available through the FACP.Refer to the manufac- Marker Base Alignment Notch turer's published instructions for proper use. q° Additionally,canned aerosol simulated smoke(canned smoke agent)may Gres°re be used for smoke entry testing of the smoke detector. Tested and ap- Base 86j° proved aerosol smoke products are: Alignment Notch LED Manufacturer Model Magnet Test Marker LED HSI Fire&Safety 25S,30S(PURCHECK) C2021-01 SDi SMOKE CENTURIAN, SOLOA4, FIGURE 4:CLEANING THE PHOTO DETECTOR SMOKESABRE,TRUTEST No Climb TESTIFIRE 2000 Sensor Cover When used properly,the canned smoke agent will cause the smoke detec- tor to go into alarm.Refer to the manufacturer's published instructions for Sensing Chamber Cover Cover and Screen proper use of the canned smoke agent. Removal Tabs Sensing Chamber ACAUTION Canned aerosol simulated smoke(canned smoke agent)formulas will vary by C2022-00 manufacturer. Misuse or overuse of these products may have long term ad- verse effects on the smoke detector.Consult the canned smoke agent manufac- SPECIAL APPLICATION turer's published instructions for any further warnings or caution statements. When configured at the fire alarm control panel,this detector is capable of op- erating in a special application mode such that it has a higher sensitivity than C. Remote Test. is normally allowed by UL 268 for areas where early warning is important.In ASD-PL3R and ASD-PL3R-IV can be remotely tested using the RTS151 or this mode,the detector does not comply with the Cooking Nuisance Smoke RTS151KEY test accessories.Refer to the DNR(W) manual for wiring dia- Test. Detectors (Sampling ports) set to the special application mode are not grams. Maximum test response time may be up to two communications suitable for use in areas where cooking appliances may be used. If cooking from the panel. appliances are used within the protected space,a normal application detector A sensor that fails any of these tests may need to be cleaned as described or normal application mode must be used for that area. under CLEANING,and retested.When testing is complete,restore the system Special application mode is not for general use and the detector may be more to normal operation and notify the proper authorities that the system is back prone to false alarms if used in unsuitable environments. While no list is in operation. all-inclusive,some examples of unsuitable environments for special applica- CLEANING tion mode are areas with airborne particulate or aerosols including sawing, Before removing the detector, notify the proper authorities that the smoke drilling, and grinding operations, textile or agricultural processing, or areas detector system is undergoing maintenance and will be temporarily out of With engines that are not vented to the outside.A complete list of aerosol and service. Disable the zone or system undergoing maintenance to prevent un- particulate sources is available in the Annex of NFPA 72. wanted alarms. Suitable environments for special application mode could include early warn- 1. Remove the sensor to be cleaned from the system. ing for hospitals,museums,assisted living and other areas that do not have 2. Remove the sensor cover by pressing firmly on each of the four removal airborne particulate or aerosols. tabs that hold the cover in place. Refer to the fire alarm control panel documentation for information on how to 3. Vacuum the screen carefully without removing it. If further cleaning is configure the detector for special application mode. required continue with Step 4,otherwise skip to Step 7. 4. Remove the chamber cover/screen assembly by pulling it straight out. Please refer to insert for the Limitations of Fire Alarm Systems FCC STATEMENT DEVICE AND SYSTEM SECURITY This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference, Before installing this product ensure that the and(2)this device must accept any interference received,including interference that may cause undesired operation. tamper seal on the packaging is present and NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits unbroken and the product has not been tampered are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio with since leaving the factory.Do not install this frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there product if there are any indications of tampering. is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, If there are any signs of tampering the product which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following should be returned to the point of purchase. measures: It is the responsibility of the system owner to -Reorient or relocate the receiving antenna. ensure that all system components,i.e.devices, -Increase the separation between the equipment and receiver. panels,wiring etc.,are adequately protected to -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. avoid tampering of the system that could result -Consult the dealer or an experienced radio/TV technician for help. in information disclosure,spoofing,and integrity This Class B digital apparatus complies with Canadian ICES-003. violation. Gamewell-FCI®and VelocitO are registered trademarks of Honeywell International,Inc.Testifire®is a registrered trademark of SDi,I.I.C. 2 I56-6536-001 ©2019 Gamewell-FCI.09/23/2019 �` InnovairFiefm_ Gamewe11 Series FIRE® ROL NSSTRRUUMEINM Duct Smoke by Honeywell Detector Accessories Description Notification and Test Accessories The InnovairFlex Series Duct Smoke Detector accessories SMOKE add functionality to the duct detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All Gamewell-FCI duct detectors and accessories are UL Listed. T � The following duct smoke detector accessories are avail- able %NONE=, • APA151 Piezo Annunciator T • MHR Mini-Horn, Red • MHW Mini-Horn,White • RA100Z/RA100ZA Remote Annunciator REmote Test Station • IRTS151KEYI Remote Test Station with Key • H162 Multi-Signaling Accessory • AOS Add-On Strobe InnovairFlex-Series Accessories • RTS2-AOS Multi-Signaling Accessory Features The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible APA151 piezo annunciator offers a new style and pro- alarm signal, a red LED to indicate alarm status, and a vides enhanced audible alarm signals green LED to indicate power status. It is intended for use with Gamewell-FCI 4-wire conventional duct smoke detec- tor applications without a system control panel, to comply temporal and continuous tones for both high and low with NFPA 90A. volume settings The MHR and MHW SpectrAlert®Advance mini-horns fea- RA100Z and RA100ZA remote annunciators flexible ture temporal or continuous tones at high and low volume versatility are used for both conventional and intelligent settings. Their small footprint allows mounting to single- applications gang back boxes for applications where a small device is RTS151 an RTS151 KEY remote test stations are desired. designed to test duct detectors from remote locations The RA10OZ and RA10OZA remote annunciators are RTS2 and RTS2-AOS multi-signaling accessories are designed for both conventional and intelligent applications. used with the InnovairFlex 4-wire conventional duct Their red LED provides visual indication of an alarm condi- smoke detectors tion. The RTS151 an RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi- colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for An ISO 9000-2000 Company alarm. SIGNALING InnovairFlexT'and Sync-CircuitTA1 are trademarks and SpectraAlert0 is a registered trade- UL FM mark of Honeywell International Inc. LISTED - GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2009 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60532 Rev.A page 1 of 3 Description (Continued) Specifications, Duct Smoke Detector Accessories (Continued) The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional RTS151 Remote Test Station duct smoke detectors. These accessories include a key Power Requirements: Alarm LED:2.8 to 32 VDC, switch that can be used to select one of two connected 12 mA max. sensors to be tested, reset, or both by a push button Total Current: 105 mA max. switch.They also enable sensitivity measurements using Test Switch: 10 VA @ 32 VDC the SENS-RDR sensitivity reader (sold separately). The Reset Switch: 10 VA @ 32 VDC AOS (Add-On Strobe) is an optional accessory included Alarm Response Time: 40 seconds max. with the RTS2-AOS model. Temperature Range: -10°C to 60°C (14°F to 140°F) Relative Humidity: 95% non-condensing Specifications, Duct Smoke Detector Wire Gauge: 14 to 18 AWG Accessories Dimensions: 4.8"H x 2.90"W x 1.4"D APA151 Piezo Annunciator (12.1 H x 7.3 W x 3.5 D cm) Voltage: Regulated 24 VDC RTS15Peaqirements: emote Test Station with Key Operating Voltage: 16 to 33 VDC Power Power LED(Green): 14 to Maximum Alarm Current: 30 mA 35 VDC, 12 mA max. Temperature Range: 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 Relative Humidity: 10 to 93%non-condensing VDC, 12 mA max. Wire Gauge: 12 to 18 AWG Total Current: 105 mA max. Dimensions: 4.6"H x 2.9"W x .45"D Alarm Response Time: 40 seconds max. (11.6 H x 7.3 W x 1.1 D cm) Temperature Range: -10°C to 60°C (14°F to 140°F) MHR/MHW SpectrAlert@ Advance Mini-Horns Relative Humidity: 95% non-condensing Voltage: Regulated 12 DC or FWR Wire Gauge: 14 to 18 AWG (Full Wave Rectified)or Dimensions 4.6"H x 2.75"W x 1.8"D Regulated 24 VDC or FWR (11.6 H x 6.9 W x 4.5 D cm) Operating Voltage: 8 to 33 VDC(9 to 33 VDC with Sync-Circuit"' Module) Sounder Current Draw: 22 mA RMS max. RTS2 and RTS2-AOS Multi-signaling Accessory at 8 to 17.5 Volts DC Voltage: 20 to 29 VDC 17 mA RMS max. Power Requirements: at 8 to 17.5 Volts FWR Standby: 3.0 mA max. 29 mA RMS max. Trouble: 16.0 mA max. at 16 to 33 Volts DC 25 mA RMS max. Alarm without strobe: 30 mA max. at 16 to 33 Volts FWR Alarm with strobe: 55 mA max. Temperature Range: 0°C to 49°C(32°F to 120°F) Sounder: 85 dBA at ten feet Humidity Range 10 to 93%non-condensing Temperature Range: -10°C to 60°C(14°F to Nominal Sounder 140°F) Frequency: 3 kHz Relative Humidity: 95% non-condensing Wire Gauge: 12 to 18 AWG Wire Gauge: 14 to 22 AWG Dimensions 4.6"H x 2.9"W x 0.45"D Dimensions: 4.8"W x 5.3"H x 1.6"D (11.6 H x 7.3 W x 1.1 D cm) (12.1 W x 13.4 H x 4.0 D cm) For the very latest product specifications and listing infor- RA100Z/RA100ZA Remote Annunciator mation, please visit the Gamewell-FCI Web site at Voltage Range: Conventional System:3.1 to www.gamewell-fci.com. 32 VDC Intelligent System: 18to32VDC Maximum Alarm Current: 12 mA Dimensions: 4.6"H x 2.8"W x 1.3"D (11.6 H x 7.1 W x 3.3 D cm) GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60532 Rev.A page 2 of 3 www.gamewell-fci.com Accessories Gamewell-FCI provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation.As with our duct smoke detectors, all duct smoke detector accessories are UL Listed. SMOKE LMMA Figure 1 RTS151 UL S2522 Figure 2 RTS151KEY UL S2522 Figure 3 APA151 UL S4011 Figure 4 RTS2-AOS UL S2522 b -- VqPW Figure 8 RTS2-AOS with PS24LOW Figure 5 RA10OZ UL S2522 Figure 6 MHW UL S4011 Figure 7 MHR UL S4011 Strobe and PS12/24 LENSW lens Ordering Information Part Number Description Accessories Part Number Description Part Number Description APA151 Piezo Annunciator RTS151 KEY Remote test station with key lock MHR Mini Horn, Red RTS2 Multi-signaling accessory MHW Mini Horn,White AOS Add-On Strobe RA100Z/RA100ZA Remote annunciator alarm LED RTS2-AOS Multi-signaling accessory RTS151 Remote test station GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60532 Rev.A page 3 of 3 PWC North County Community Office PUD Fire Alarm Bldg B Job Number: 24339-C-2 24339-C-2 -PWC North County Community Office PUD Fire Alarm Bldg B PWC North County Community Office Table of Contents Spec # Section Manufacturer Doc Name Doc # Fire Alarm Gamewell - FCI SLP BLK 1 Gamewell - FCI HPF PS10B 2 Space Age SS000685 3 System Sensor SCWL 4 System Sensor PC2WL 5 System Sensor SWL 6 System Sensor P2WL 7 System Sensor P2WK 8 Gamewell - FCI ASD PI-3 IV 9 Gamewell - FCI MS 7AF 10 Gamewell - FCI AOM 2RF 11 Functional Devices Inc. RIB01 BDC 12 Gamewell - FCI AMM 2F 13 Gamewell - FCI ASD PL3R IV 14 Gamewell - FCI RTS151 KEY 15 Fire Alarm 0 _ Gamewell S3 Series E m 31 INSTRUMENTS control Control Panel by Honeywell Description Small Analog Addressable Fire Alarm Control Panel The Gamewell-FCI,S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high-end processing power. It offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks. r g r r r+ • Up to 64 nodes using the 7100 Series panel. `- • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ether- net connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. S3 Series The basic S3 Series consists of an SLP (Smart Loop Features Panel) main board, LCD-SLP touchscreen display, SLC Listed per ANSI/UL®Standard 864 9th Edition. loop personality modules, and 7 amp power supply. The IBC Seismic Certified. SLP provides either one or two SLC loops in Class A or B Allows one SLC loop(expandable to two loops)that configuration that supports either of the following protocols: supports either System Sensor or Apollo devices in • Up to 318 devices per loop using the System Sensor® Class A or Class B(Style 4,6 or 7). protocol. If you add a second loop module, it increases System Sensor supports up to 318 intelligent the maximum device count to 636 devices. devices and each SLC loop supports the following. • Up to 126 devices per loop using the Apollo protocol. If up to 159 detectors. you add a second loop module, it increases the maxi- up to 159 modules(expandable to 636 maximum mum device count to 252 devices. per panel). • Apollo supports up to 126 intelligent detectors and Four Class B or two Class A NACs can be wired and syn- modules per SLC.(Expandable to 252 maximum per chronized using the System Sensor, Cooper-Wheelock, or panel). Gentex strobes. To retrofit the SLP on the existing audible/ Includes a high resolution(4.3")(10.92 cm)color touch- visual appliances, the on-board Electronic EOL (EEOL) screen display. automatically adjusts to the EOL resistor in the field. Supports a network system of up to 122 nodes (includes E3 Series®panels)or up to 64 nodes A 4.3" (10.92 cm) color touchscreen display screen shows (includes 7100 Series). the following: Provides 7.0 amp power supply(120VAC or 240VAC). • Events on the system includes four Class B or two Class A built-in Notification • Status of analog addressable devices Appliance Circuits(NAC). Provides selectable System • Complete diagnostic fault codes/messages Sensor,Cooper-Wheelock,or Gentex strobe synchroni- zation.Five programmable function buttons with LED status for accessibility to the following functions: Supports up to 32 serial annunciators(LCD, LED only, LED Switch). -Disable/Enable -Trouble Acknowledge -Bypass Output -Alarm Acknowledge -Lamp Test -Custom-defined SIGNALING ® ® O �,- j�� City of E3 Se do nalinc.System Sensor and FocalPo nt®are registered trademarks of Honeywell int M EA r Chi-,. 0 �tatio FM - LISTED FD1 - Approved UL is registered trademark ofUnderwriters laboratories Inc. 51869 APPROVED COA-06#61627165.1703:0776 CIa55 1 Reference CertiRcate of Compliance VMA-45894-02C Is0 900 Som GAMEWELL-FCI OVAE LITY SYSTEMS 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for untomlation only,are not intended for installation purposes,and are subject to change without notice.Nb responsibility is assumed by Gamewell-FCI for theiruse. 52014byl>oneyw llInternationalInc. AD tights reserved. www.gamewell-fci.com 9021-60730 Rev.F page 1 of Application Features (Continued) The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the Offers an Ethernet port for programming,a variety of small to mid-sized buildings. Analog technology delivers system reports, and a FocalPointR Graphic Workstation the benefits of a simple system installation, while a user- connectivity. friendly interface makes panel operation and system main- Provides two fully-programmable Form-C contacts for tenance quick and intuitive. Fire,Trouble,and Supervisory. • TimeCap-Saves time and date up to 48 hours without Smart Panel Programming any power or battery. Using Boolean logic programming, the installer may cus- Automatically adjusts to any NAC End-of-Line Resistor tomize the system to precisely suit the needs of the build- (EOL)value(1 k-55k ohm)for legacy audible/visual ing owner. Auto-programming allows the installer to appliances. instantly locate all the devices on the SLC loop. Removable display can be used as a remote annunciator. Simple, Intuitive Display Suitable for pre-action deluge applications. The front panel display provides a user-friendly interface Optional Accessories for the operator's control. A 4.3" (10.922 cm) color touch- DACT-E3-Dialer screen displays system status, event details and service The Digital Alarm Communication Transmitter sends digital modes.On the front of the panel,six LEDs show the follow- signals over telephone lines to the central station. It con- ing conditions. nects to the SLP through an RS-485 bus. Using the Con- Fire Silenced tact ID format, the DACT-E3 provides a four-digit account • Hazard(Gas or CO) AC Power code followed by the code/numbers listed below: • Supervisory Trouble • Three-digit Event Code Five custom programmable switches allow the user quick Two-digit Group Number access to common functions specific to the building like Three-digit Contact Number device disable,output bypass and device status. All codes are used to provide specific point identification. Perfect for Retrofits The DACT-E3 is compatible with digital alarm communica- The S3 Series is well-suited for retrofit applications. The for receivers (DACRs) that receive the following signaling SLP provides a simple way to upgrade your fire protection formats: system. It is designed to be an upgrade solution for the leg- Contact ID SIA acy FCI 7100 and Gamewell 602 Series panels.An added 3+1 4+2 feature is the SLP's EEOL. Using EEOL, the installers can For more information, refer to the following data sheets: automatically identify the EOL for existing audible/visual DACT-E3 Data Sheet, P/N: 9020-0610 appliances. FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 Flexibility for Future Growth RPT-E3-UTP-Network Repeater Card The S3 Series can be expanded to add a second SLC loop The Network Repeater allows the SLP fire control panels to without replacing the entire system. Using the RPT-E3- connect to the broadband network from remote locations. It UTP Network Repeater, you can network up to 64 nodes connects to other networked units using unshielded, (122 nodes with the ANX node expander) using either twisted-pair wiring. The RPT-E3-UTP is available with two twisted-pair or fiber-optic. The built-in Ethernet port allows add-on fiber modules: the connection to the Gamewell-FCI's FocalPoint FML-E3 connects to the network using either 62.5/125 Graphical Workstation. micron multi-mode fiber. • FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100-Remote Annunciator The Remote serial display features an 80-character dis- play. The LCD-7100 can be surface or flush-mounted on a . . ■ . standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet,P/N:9020-0486. ASM-16-Addressable Switch/LED Module There are 16 programmable switches available to perform Figure 1 LCD-SLP Display any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g.ON, OFF,Activated,etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N:9020-0554. ANU-48-48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL®Listed annunciator enclosure. Up to 16 ANU-48 mod- ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N:9020-0596. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.F page 2 of 4 www.gamewell-fci.com Figure 2 illustrates the SLP-BB Cabinet Enclosure. Specifications SLP-BB CABINET Device Loops Up to two Class A or B,System Sensor BACKBOX units,each loop supporting up to 318 device addresses. ® ' 2 Or- Apollo units,each loop supporting up SLP-BB CABINET ® to 126 device addresses per loop. OUTER R ® NAC circuits 4 Class B or 4 112 Class A(2.0 A each circuit), 6.0 A total NAC Operating Voltage 24 VDC "04-3 ® NAC Minimum Voltage 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit o Operating Voltage 24 V peak-to-peak ® Input Voltage 120 VAC,60 Hz a 240 VAC 50-60 Hz 2 0 201/8"H Input Current 120 VAC,2.75 amps max. 240 VAC, 1.4 amps max. Aux Power 1(Continuous) 24 VDC nominal at 1.OA Aux Power 2(Resettable) 24 VDC nominal at 1.OA • 0 1® ® Base Panel Current draw Standby:0.111 amps Alarm: 0.243 amps Operating Temperature 32e-120c F(0e-49e C) ® Relative Humidity 93%(non-condensing) Battery Charger Voltage +24 VDC Battery Charger 55 A/H batteries(cabinet 4112"D Capacity accommodates 12 A/H batteries) Alarm,Trouble& Supervisory Relay Contacts Form-C,2 amps @ 24VDC(resistive) Cabinet Dimensions: SLP-BB Dimensions 14 1/2"W x 20 1/8"H x 4 1/2"D Figure 2 SLP Enclosure (36.83 Wx 51.18 Hx 11.43 Dcm) S3BB-RB Dimensions 19 3/8"W x 19 3/8"H x 4.5"D (49.22 W x 49.22 H x 11.43 D) Supports up to 636 Velociti devices or252XP95 devices_ S3 Series Fire Alarm Control p� ' Panel R a - - MCS-COF Networkable up to 122 - Intenigent Duct Detector F.,IC,rbon Monoxide panels using twisted - / Detector pair wire or fiber optics. 0"0""r y I• a r+ ASD-PL2F ASD-LS Photo Detector Laser Detector A .T .. 1� AMM-21F A M-2 IF Mini Monitor Module Dual lnpuVOutput Motlule Local Energy 1\\ E3 Series, Trip Panel AOM-2RF MS-7AF 0 w EthernetDO _ Relay Module Pull Station N N LCD-7100 LCD-SLP LCD-E3 -n 2emote Annunicator Color ToucM1[creep Remote Annunicator 3 Annuni n 13 FocalPoint Workstation ASM-16 LANU�-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 SLP Panel Configuration GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60730 Rev.F page 3 of 4 Ordering Information Ordering Information (Continued) Part.WwAber Description Part Number Description SLIP-BILK SLP addressable FACP in black SLP-BB Accessories enclosure. DACT-E3 Digital Dialer Communicator Requires either an SLC-PM or an Transmitter for the S3 or E3 Series. SLC95-PM for SLC loops. LCD-SLP LCD Color Touchscreen display with SLP-RED SLP addressable FACP with red door five programmable switches. and black SLP-BB backbox. For use with the S3 Series panels. Requires either an SLC-PM or an Remote annunciation requires the E3 SLC95-PM for SLC loops. Series A2 cabinet. SLP-RED-G SLP addressable FACP (E3BB-BA2, E3BB-RA2) 240VAC power supply with red door and RPT-E3-UTP Network repeater card with twisted- black SLP-BB backbox. pair fiber connections require either an Requires either an SLC-PM or an FML-E3 or an FSL-E3 card. SLC95-PM for SLC loops. FML-E3 Multi-mode fiber-optic card for one SLC-PM System Sensor Loop Card- 1 loop used channel on the RPT-E3-UTP. for 159 sensors and 159 modules. FSL-E3 Single-mode fiber-optic card for one For use with the SLP-E3 panels only. channel on the RPT-E3-UTP. SLC95-PM Apollo Loop Card-1 loop used for 126 SLP-RB SLP motherboard sensors and modules. For use with the SLP-E3 panels only. For use with the replacement or the retrofit solutions. FLPS-7-1113 SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mount- ing plate. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM S3BB-RB SLP red cabinet with an inner door for the mounting display behind the plexiglass. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM LCD-7100 Remote Serial LCD Annunciator ASM-16 Remote Programmable Addressable Switch/LED Module ANU-48 Remote LED Driver Module GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.F page 4 of 4 www.gamewell-fci.com j SERIES 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Gamewell-FCI.The HPF-PS6 is a 6 amp and the HPF-PS10 is a 10 amp,remote power supply with battery charger that maybe connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a standalone power supply.The PS Series provides 24 VDC power for NACs(notification appliance circuits)configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync protocol options.The PS Series also provides auxiliary power,constant or resettable,suited for detectors,annunciators,door holders,and other fire alarm system peripherals.The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS HPF-PS6/10 • Up to five(6 amp model)or seven(10 amp • Two Form C normally-closed trouble relays model)independently-configurable,power- for AC Trouble and General Trouble limited output circuits for: • 6 or 10 amp full load output,respectively, —Class B and/or Class A NACs with 3 A maximum/circuit —Class B and/or Class A resettable or non- • Individual NAC power and trouble LEDs for resettable 24V auxiliary power diagnostic efficiency —door holder power • Trouble history mode for diagnostic support • Converts from Class B to Class A wiring • Wide range end-of-line supervision value without losing any outputs using the ZNAC- (normal:2-27K ohms) PS converter card(sold separately) • Selectable earth fault detection(enable or • Optimal for powering four-wire smoke disable) detectors,annunciators,and other system • AC trouble report delay timer peripherals requiring regulated power • Completely configurable via onboard DIP • Optional addressable control,monitor,and switches,no extra software required relay modules and power-supervision relay • Self-contained in compact,locking cabinet (EOLR-1) constructed of heavy gauge steel with a • Configurable for ANSI°Temporal 3 or corrosion-resistant powder coat chip and Temporal coded output scratch-resistant finish HPF-PS6110B • UL-Listed NAC synchronization using • Cabinet designed with ten double • Works with any UL 864 FACP which utilizes System Sensor',Wheelock',Gentex°,or knockouts and a removable door for ease of an industry-standard reverse-polarity AMSECO°appliances installation and wiring notification circuit • Synchronization can be triggered from • Includes integral battery charger capable of • HPF-PS6/10includethe-Honeywell Power FACP NAC/remote sync outputs,cascaded charging up to 33 AH batteries Products lock set(PN:17059)and key(PN: power supply,or a control module,single or • Cabinet can house two 7 AH or 18 AH 17051) multi,which may be housed within the batteries power supply cabinet • Battery charger may be disabled via DIP • Ability to cascade up to four power supplies switch for applications requiring larger • Two(6 amp model)orthree(10 amp model) batteries and external battery charger fully-isolated input/control circuits which • Removable terminal blocks accommodate Honeywell can be programmed to any output up to 12 AWG(3.1mm2)wire ORDERING INFORMATION HPF-PS6:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS613:6.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black HPF-PS10:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red HPF-PS10B 10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,black ZNAC-PS:Optional Class A converter card,sold separately AOM-2SF:Addressable Control Module for one Class B or Class A zone of supervised,polarized Notification Appliances.Notification Appliance Circuit option requires external 24 VDC to power notification appliances. AOM-2RF:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch AMM-4F:Addressable Monitor Module for one zone of normally open dry-contact initiating devices.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Class B or Class A AMM-21F:Dual Monitor Module.Same as AMM-4F except it provides two inputs for Class B wiring only AMM-21RIF:Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only MMO-6SF:Six-circuit supervised control module MMO-6RF:Six Form-C relay control module EOLR-1:12/24VDC end-of-line relayfor monitoring four-wire smoke detector power BAT-1270-BP:Battery,12 volt,7.0 AH,5-pack(two required) BAT-12180-BP:Battery,12 volt,18AH,2-pack BAT-12330:Battery,12 volt,33AH SEISKIT-MULTI-1:Seismic kit for the PS Series.Includes bracket and hardware for two 7AH or two 18AH batteries. 17070:Alternate Honeywell Gamewell-FCI lock set,PK-625,3/8" cam Page 2 of 3—9021-61096:B•1/25/2021 HPS SERIES TECHNICAL SPECIFICATIONS PRIMARY(AC)POWER SECONDARY POWER(BATTERY) HPF-PS6(B):120VAC,50/60 Hz,5.OA CHARGING CIRCUIT Sensor' maximumtrademarkSupports lead-acid batteries only HPF-PS10(B) 120VAC,50/60 Hz,6.2 A • Float-charge voltage:27.6 VDC International,Inc.Wheelock' maximum Maximum current charge:1.5 A registered trademark of Cooper Wire Size:#12-14 AWG with 600 V • Maximum battery capacity:18 AH(inside Technologies Company.Gentexl is insulationregistered _' _' trademark' cabinet) COMMAND INPUT CIRCUIT • Maximum battery charging capacity:33 AH (external cabinet) registered trademark of Potter Trigger Input Voltage:9 to 32 VDC Electric Signal Company, Trigger Current:2.0 mA(16-32 V);Per PHYSICAL ANSIO is a registered trademark of Input:1.0 mA(9-16 V) Dimensions:20.0"H x 14.5"W x 3.5"D(cm: the American National RELAY CIRCUITS 50.8H x 36.83W x 8.91D) Institute,Inc. Trouble Contact Rating:4 A at 24 VDC Weight:with two 7Ah batteries is 24 pounds by Honeywell 'nal (10.9 kg),with two 18 AH batteries is 39 Inc.All rights ' OUTPUT CIRCUITS pounds(17.7 kg) Unauthorized use of this document • 24 VDC filtered STANDARDS AND CODES is strictly prohibited. • HPF-PS613:TB8-TB9—1A Regulated,3A The HPF-PS complies with the following This document is not - •-•tobe special applications;TB10-TB12—0.3A standards: usedfor installation purposes. Regulated,3A special applications NFPA 72:National Fire Alarm Code . • • • .• . • • HPF-PS10B:T138JI311-1.5A Regulated, UL 864:Standard for Control Units for Fire up-to-date• ' accurate.We cannot 3A special applications;TB12-TB14—0.3A Alarm Systems(NAC expander mode) cover all specific applications or Regulated,3A special applications UL 1481:Power Supplies for Fire Alarm anticipate all "' • 6.0 A(HPF-PS613)or 10.0(HPF-PS10B) Systems specifications are subjectto change maximum total continuous current for all without notice. outputs AGENCY LISTINGS AND APPROVALS Country of origin:USA These listings and approvals apply to the modules specified in this document.In some cases,certain modules or applications may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest listing status. UL Listed:S24562 CSFM:7315-1637:0505 FDNY Approved FM Approved Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT06472-1610 Honeywell 203.484.7161 � 9021-61096 B 01/21 www.gamewell-fci.com ©2021 Honeywell International Inc. Q[0*m;R 0 S� S� Lm SIGNALING UL LISTED ];;;;;;;iii0"FAD ACE-11 FIRE ALARM DO CUM BUTS The FAD is the perfect fit to m eet the demanding E ALARM DOCUMENTS code requirem ents today. SAE's num ber one goal is to m anufacture code com pliant solutions and this Records Pr•• -ms Software product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firm\Aare version num bers shall be m antained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4G B USB flash drive it stores your fire alarm software safe and secure elim hating the occurrences of the soft- ware not being on site when technicians arrive to service the system .Along with your fire alarm soft- Standard Features: ware you can store your test & inspection docu- m ents, service records, m anuals &AS built drawings • Installed with a 4 gig digital flash drive for the system .Using a standard USB B connector it with USB B connector allows you to plug in with any standard SIB printer • 2 Key ring hooks to hold system keys cable to upload or download information. • B usiness card holder for key contacts • & erall Dim eisions are 12" x 13"tall and 2 1/4 deep The FDB is designed to hold critical m anuals and • 1 6 gauge steel box and cover for security documents with a durable steel retainer. It has • D urable powercoat baked on finish designated hooks to organize key rings and hold other colors available im portant business cards for easy access and • S tandard3/4'cat 30 key lock other lock w- reference. Inside the cover it has a organized note sem dies available table that allows for documentation for passwords • S olid stainless steel piano hinge and other critical system information. • P erm anently screened white ink 1" high "Fire Alarm Docum efts" • L egend sheet for passwords and system inform ation _ I �? ��/ �� ISO 9001 Space Age Electronics, Inc. [07] �r`III� REGISTERED www.Isae.com NFPA COMPANY 800.486.1723 Toll Free MEMER �,7 M cde In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, ED0549 L T10559 R ev.D 1/2 .lust Solutions! �SPACEAGE ELECTRONICS, INC. Specifications: The fire alarm docum efts box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be perm anently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 m cunting holes. Inside the enclosure will accom m adate standard 8 1/2 x 11 m anuals and loose docum Ent records that will be protected within the enclosure.A legend sheet will be perm aiently attached to the door for system required documentation, key contacts and system inform ation. The FAD will have securely m cunted inside a m him un of 4 G gabyte digital flash m eTt cry drive with a standard USB B connector for uploading and downloading inform ation. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to m cunt standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector is ,�a.,.m.xb,m,ob,.P,x awa,ara.,a> rya Property Information Mhin—Required Documentation(SIG FUN) Key Ring �� E"�r' d-0. Hooksan�, Certifications and Approvals - aam mi Z!System Installs Contractor: oxu 1�1 o,al.-1 «om eu/nxmn:xm.m:.x1.a re wn n Enn09m nu we a mm..or a mm d aw o.� 1o1 Business o ­,noAll ; �d�c,aroo� „nma,xa�.�mo, Card Holder 16.5 Authouty,Ha ving�unstli Jurisdiction:ion: 1.�poEc (o All-rpmc alp a� oh. Ph—x,Allch— All aatiro All `�♦ •i11, ��• o —_— +ouin E—o,u�.m anon �w..xn zs.eam vaa Equipment Informatlon oa•`°o(a"�"t,°a'""apu. „xo l spennae Eknnnka,irc.5 etnocsename a rg, no,sta a oaneann3 wxu.tsea.com LT10aCC Rev.'I Legend sheet for storing system inform ation including contacts,sign-off,maintenance & test inform ation,and alternate locations of additional records. O idering Inform ation: Part# D escription SS000685 Fire Alarm Storage Cabinet RED 7Free Space Age E SS000686 Custom screening w th your Logo www.lsae.co800.486.172 Check out our Infinity line eFAD single gang 2 Gig digital storage 508 4485.096 solutions (IAM EFAD) 508.485.4740ax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0549 L T10559 R ev.D 2'2 INSTALLATION AND MAINTENANCE INSTRUCTIONS ��T�� 0. Selectable Output SENSOR' CD Horn Strobes, Chime Strobes 3825 Ohio Avenue,St.Charles,Illinois 60174 -6495 and Strobes - Ceiling Mount 800/736-7ww FAX: msens r.com www.systemsensor.com For use with the following models: Ceiling Mount Horn Strobes:PC2RL,PC2WL Ceiling Mount Chime Strobe CHSCWL Ceiling Mount Strobes:SCR SCWL, CWL-CLR-ALERT PRODUCT SPECIFICATIONS Standard Operating Temperature: 32°F to 120°F(0°C to 49°C) Humidity Range: 10 to 93%Non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage: Regulated 12VDC or regulated 24DC/FWR Operating Voltage Range: 8 to 17.5V(12V nominal)or 16 to 33V(24V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5V(12V nominal)or 16.5 to 33V(24V nominal) Input terminal wire gauge: 12 to 18 AWG DIMENSIONS FOR PRODUCTS AND ACCESSORIES MOUNTING BOX OPTIONS CEILING PRODUCTS Diameter Depth 2-Wire Indoor Products Strobe,Chime Strobe and Horn Strobe 6.83" 2.47" (173.5mm) (62.7mm) 4"x 4"x 11/2",Single Gang,Double Gang, Strobe,Chime Strobe,and Horn Strobe with 6.92" 2.50" 4"Octagon,SBBCRL/WL(ceiling) SBBCRL/WL Surface Mount Back Box (175.8mm) (63.5mm) NOTICE:This manual shall be left with the owner/user of this equipment. BEFORE INSTALLING produce temporal coded signals.Signals other than those used for evacuation Please read the System Sensor Audible Visible Application Reference Guide, purposes do not have to produce the temporal coded signal. System Sensor which provides detailed information on notification devices, wiring and recommends spacing notification appliances in compliance with NFPA 72. special applications.Copies of this manual are available from System Sensor. SYSTEM DESIGN NFPA 72 and NEMA guidelines should be observed. The system designer must make sure that the total current draw by the devices Important: The notification appliance used must be tested and maintained on the loop does not exceed the current capability of the panel supply,and following NFPA 72 requirements. that the last device on the circuit is operated within its rated voltage. The GENERAL DESCRIPTION current draw information for making these calculations can be found in the System Sensor series of notification appliances offer a wide range of audible tables within the manual.For convenience and accuracy,use the voltage drop and visible devices for life safety notification.Our 2-wire horn strobes,chime calculator on the System Sensor website(www.systemsensor.com). strobes and strobes come with 8 field selectable tone and volume combina- When calculating the voltage available to the last device, it is necessary to tions and 7 field selectable candela settings.Intended for indoor applications consider the voltage due to the resistance of the wire.The thicker the wire,the and approved for ceiling mount installations. smaller the voltage drop.Wire resistance tables can be obtained from electri- 2-wire horn strobes and strobes are public mode notification appliances in- cal handbooks.Note that if Class A wiring is installed,the wire length may tended to alert occupants of a life safety event. The 2-wire chime strobe is be up to twice as long as it would be for circuits that are not fault tolerant. a private mode notification appliance.The horn is listed to ANSI/UL 464 re- The total number of strobes on a single NAC must not exceed 69 for 24 volt quirements (public mode) and the strobe is listed to ANSI/UL 1638 (public applications. mode).2-wire chime strobe is a private mode notification appliances intended AVAILABLE TONES to alert trained personnel to investigate a life safety event and take appropriate System Sensor offers a wide variety of tones for your life safety needs,includ- actions.The chime portion of the chime strobe is listed to ANSI/UL 464(pri- ing temporal 3 pattern(1/2 second on,1/2 second off, 1/2 second on,1/2 second vate mode)and the strobe portion is listed to ANSI/UL 1638(private mode). off,1/2 second on,11/2 off and repeat)which is specified by ANSI and NFPA 72 System Sensor strobes are designed to be used in 12 VDC,24VDC,or 24V FWR for standard emergency evacuation signaling. (full wave rectified)systems.System Sensor AV devices can be activated by a To select the tone,turn the rotary switch on the back of the product to the compatible fire alarm control panel or power supply.Refer to the appropriate desired setting.(See Figure 1.)Available horn settings can be found in Table 1. fire alarm control panel manufacturer or power supply for more information. Available chime settings can be found in Table 2. System Sensor ceiling 2-wire horn strobes,2-wire chime strobes,and strobes AVAILABLE CANDELA SETTINGS are electrically backward compatible with the previous generation,since 1996, System Sensor offers a wide range of candela settings for your life safety of notification appliances. They come enabled with System Sensor synchro- needs. In order to select your candela output,adjust the slide switch on the nization protocol which requires connections to a power supply capable of rear of the product to the desired candela setting on the selector switch. (See generating the System Sensor synchronization pulses, a FACP NAC output Figure 2.) configured to System Sensor synchronization protocol, or the use of MDL3 module to generate the synchronization protocol. The candela setting can also be verified by looking into the small window on the front of the unit.See Table 3 for candela settings for ceiling products.All FIRE ALARM SYSTEM CONSIDERATIONS products meet the light output profiles specified in the appropriate UL Stan- The National Fire Alarm and Signaling Code,NFPA 72,requires that all noti- dards.(See Figures 3 to 5.) fication appliances,used for building evacuation installed after July 1, 1996, 1 I56-5846-002 10/02/2018 FIGURE 1.AUDIO SELECTOR FIGURE 2.CANDELA SELECTOR FIGURE 3.LIGHT OUTPUT-VERTICAL DISPERSION,CEILING TO WALLS L%UND 01ELEM TO FLOOR Percent of `E°'NC 4 WDELA 8ELE(T Degrees* i Rating 90 90. o ® 0 100 5-25 90 A0486-00 30-45 75 50 55 A0518.00 60 45 e e 0 TABLE 1.HORN TONES TABLE 2.CHIME TONES 65 35 Pos Tone Volume Volume 70 35 Pos Tone Setting Settin 75 30 1 Temporal High 1 1 Second Chime High 80 30 30 30 2 Temporal Low 2 1 Second Chime Low 85 25 3 Non-Temporal High 3 1/4 Second Chime High 90 25 25 20 5 ° 5 0 5 ° 5 20 25 FIUOR 4 Non-Temporal Low 4 1/4 Second Chime Low A0468-00 5 3.1 KHz High 5 Temporal Chime High Temporal FIGURE 4.LIGHT OUTPUT— FIGURE 5.VERTICAL 6 3.1 KHz Low 6 Temporal Chime Low HORIZONTAL DISPERSION DISPERSION,WALL TO FLOOR Temporal 3.1 KHz Degrees* Percent of Rating Degrees* Percent of Rating 7 Non-Temporal High 7 5 Second Whoop High 0 100 0 100 3.1 KHz 5-25 90 5-30 90 8 Non-Tem oral Low 8 5 Second Whoop Low 30-45 75 35 65 50 55 40 46 TABLE 3.CEILING-MOUNT STROBE CURRENT DRAW(mA) 55 45 45 34 8-17.5 60 40 50 27 Candela Volts 16-33 Volts 65 35 55 22 DC DC FWR 70 35 60 18 15 87 41 60 75 30 65 16 30 153 63 86 NOTE: Products set at 15 and 30 80 30 70 15 75 - 111 142 candela automatically work on 85 25 75 13 95 134 164 either 12V or 24V power supplies. 90 25 80 12 115 158 191 The products are not listed for Compound 45 24 85 12 150 189 228 12V DC operation when set to any to the left 177 226 264 other candela settings. Compound 45 24 90 12 CURRENT DRAW AND AUDIBILITY RATINGS to the right For the horn strobe,the current draw and audibility ratings for each setting is listed in Table 4.For the chime strobe,the current draw and audibility ratings for each setting is listed in Table 5.For the strobe,the current draw for each setting is listed in Table 3. A0467-00 00' 80 55 o a5 a0 35 30 A0469-00 *Tolerance of 1 degree is permitted. TABLE 4.CEILING--MOUNT HORN STROBE CURRENT DRAW(mA)AND SOUND OUTPUT(dBA) Current draw(mA) Sound Output(dBA) Pos Tone Volume 8-17.5 VDC 16-33 VDC 16-33 FWR 8-17.5 V 1633 V Setting 15 30 15 30 75 95 115 150 177 15 30 75 95 115 150 177 DC DC FWR 1 Temporal High 103 167 71 90 143 165 187 217 254 107 135 179 198 223 254 286 84 89 89 2 Temporal Low 96 165 54 71 137 161 185 211 249 78 101 151 172 199 229 262 75 83 83 3 Non-Temporal High 106 173 71 90 141 165 187 230 273 107 135 179 198 223 254 286 85 90 90 4 Non-Temporal Low 95 166 54 71 124 161 170 216 258 78 101 151 172 199 229 262 76 84 84 5 3.1 KHz High 111 164 69 94 147 163 184 229 257 108 135 179 200 225 255 289 83 88 88 Temporal 6 3.1 KHz Low 103 163 54 88 143 155 185 212 252 79 101 150 171 196 229 260 76 82 82 Tempera 7 3.1 KHz High 111 172 69 94 144 164 202 229 271 108 135 179 200 225 255 289 84 89 89 Non-Tem oral 8 3.1 KHz Non- Low 103 169 54 88 131 155 187 217 259 79 101 150 171 196 229 260 77 83 83 Temporal NOTE:Products set at 15 and 30 candela automatically work on either 12V or 24V power supplies.The products are not listed for 12VDC operation when set to any other candela settings. 2 I56-5846-002 10/02/2018 WIRING AND MOUNTING SHORTING SPRING FEATURE All wiring must be installed in compliance with the National Electric Code System Sensor notification appliances come with a shorting spring that is pro- and the local codes as well as the authority having jurisdiction.Wiring must vided between terminals 2 and 3 of the mounting plate to enable system con- not be of such length or wire size which would cause the notification appli- tinuity checks after the system has been wired,but prior to installation of the ance to operate outside of its published specifications.Improper connections final product. (See Figure 6.) This spring will automatically disengage when can prevent the system from alerting occupants in the event of an emergency. the product is installed,to enable supervision of the final system. Wire sizes up to 12 AWG(2.5 mmz)may be used with the mounting plate.The MOUNTING AND REMOVING APPLIANCE mounting plate ships with the terminals set for 12 AWG wiring. 1. Attach mounting plate to junction box using two of the provided Philips Make wire connections by stripping about 3/s'of insulation from the end of head screws.(See Figure 8.) the wire.Then slide the bare end of the wire under the appropriate clamping 2. Connect field wiring according to terminal designations. (See Figures 6 plate and tighten the clamping plate screw.We provide a wire strip guide.See and 7.) Figure 6 for wiring terminals and strip guide reference. 3. If the product is not to be installed at this point, use the protective dust ACAl1TION cover to prevent contamination of the wiring terminals on the mounting plate. Factory finish should not be altered:Do not paint! 4.To attach product to mounting plate: a.Remove the protective dust cover. ACAUTION b.Hook the tabs on the top of the product housing into the grooves on mount- Do not over tighten mounting plate screws; this may cause mounting plate ing plate. to flex. c.Pivot the product into position to engage the terminals on the mounting plate.Make sure that the tabs on the back of the product housing fully en- FIGURE 6.WIRING TERMINALS,SHORTING SPRING,AND STRIP GUIDE gage with the mounting plate. Shorting Spring d.Hold product in place with one hand,and secure product by tightening the single mounting screw in the front of the product housing. Ceiling Models only:To remove product from the mounting plate,loosen the captive mounting screw and press the locking button. FIGURE S.MOUNTING o ®® DTI WIRING TERMINALS 1.Negative(-).Line in and out 2.Positive(+).Line in and out m® 3.Positive(+).Line in and out Strip Guide A0475-01 SYSTEM WIRING The 2-wire horn strobe, chime strobe and strobe only require two wires for �m power and supervision. (See Figure 7.) Please consult your FACP manufac- �m ®® turer or power supply manufacturer for specific wiring configurations and special cases. FIGURE 7.2-WIRE CIRCUIT ° INPUT FROM OUTPUT A0492-01 FACP TO OR NEXT PRIOR o DEVICE DEVICE o o OR EOL Locking A0367-02 button A0574-00 TABLE 5.CEILING-MOUNT CHIME STROBE CURRENT DRAW(mA)AND SOUND OUTPUT(dBA) Current draw(mA) Sound Output(dBA) Pos Chime Tone Volume 8-17.5 VDC 16-33 VDC 16-33 FWR 8-17.5 V 16-33 V Setting 15 30 15 30 75 95 115 150 177 15 30 75 95 115 150 177 DC DC FWR 1 1 Second High 96 165 47 69 117 137 165 202 238 63 90 147 169 184 212 245 61 62 62 2 1 Second Low 93 162 47 68 116 137 165 200 238 63 88 147 169 183 212 244 56 55 55 3 1/4 Second High 94 161 48 70 117 138 166 202 237 65 90 149 170 184 213 246 67 70 70 4 1/4 Second Low 1 93 157 48 69 116 137 164 199 236 64 89 148 168 184 216 244 61 61 61 5 Temporal High 93 163 48 70 116 138 165 199 238 64 89 148 169 184 212 245 64 66 66 6 Temporal Low 92 160 1 47 1 69 116 136 164 198 237 63 88 147 169 1 183 212 245 59 60 60 7 5 Second High 98 169 54 77 124 146 173 206 245 75 100 155 178 193 221 255 76 78 78 Whoop 8 5 Second Low 95 166 49 71 117 144 168 202 239 68 91 148 170 186 217 248 62 64 64 Whoop NOTE:Products set at 15 and 30 candela automatically work on either 12V or 24V power supplies.The products are not listed for 12VDC operation when set to any other candela settings. 3 I56-5846-002 10/02/2018 TAMPER SCREW FIGURE 10.SURFACE MOUNTING ON CEILING For tamper resistance,the standard captive screw may be replaced with a Torx SBBCRUSBBCWL screw(sold separately). 1.To remove the captive screw,back out the screw and apply pressure to the back of the screw until it disengages from the housing. Replace with Torx ®® screw. (See Figure 9.) FIGURE 9.TAMPER SCREW IT15 Tom N6-2,5/S" SCREW-TMPR-50 A0494-02 A0493-01 FIGURE 11.CUT-OUTS FOR SPEAKER(SPK)AND STROBE(STR) INSTALLING A SURFACE MOUNT BACK BOX 1. The ceiling surface mount back box may be secured directly to the wall or ceiling. Use of grounding bracket with ground screw is optional. (See Figure 10.) STIR 2.The ceiling mount box can be used on ceiling horn strobe,chime strobe, STIR strobe as well as ceiling speaker and speaker strobe models.Use the STR cut- outs for ceiling horn strobe,chime strobe and strobe installation needs. (See A0495-00 Figure 11.) 3.Threaded knockout holes are provided for the sides of the box for a/4 inch and 1/2 inch conduit adapter. Knockout holes in the back of the box can be FIGURE 12.KNOCKOUT AND VS00/V700 REMOVAL FOR SURFACE used for a/4 inch and 1/2 inch rear entry. MOUNT BACK BOX 4.To remove the a/4 inch knockout,place the blade of a flat-head screwdriver Wire Mold Removal along the outer edge and work your way around the knockout as you strike the screwdriver. (See Figure 12.) 1/2 inch NOTE: Use caution not to strike the knockout near the top edge of the or a/4 inch surface mount back box. 5. V500 and V700 raceway knockouts are also provided. Use V500 for low o profile applications and V700 for high profile applications. Ao465-01 A0466-01 6.To remove the knockout,turn pliers up.(See Figure 12.) AWARNING THE LIMITATIONS OF HORN/STROBES The horn and/or strobe will not work without power.The horn/strobe gets its power The signal strobe may not be seen.The electronic visual warning signal uses an extremely from the fire/security panel monitoring the alarm system.If power is cut off for any rea- reliable xenon flash tube.It flashes at least once every second.The strobe must not be son,the horn/strobe will not provide the desired audio or visual warning. installed in direct sunlight or areas of high light intensity(over 60 foot candles)where the The horn may not be heard.The loudness of the horn meets (or exceeds) current visual flash might be disregarded or not seen.The strobe may not be seen by the visually Underwriters Laboratories'standards.However,the horn may not alert a sound sleeper or impaired. one who has recently used drugs or has been drinking alcoholic beverages.The horn may The signal strobe may cause seizures.Individuals who have positive photoic response to not be heard if it is placed on a different floor from the person in hazard or if placed too visual stimuli with seizures,such as persons with epilepsy,should avoid prolonged exposure far away to be heard over the ambient noise such as traffic,air conditioners,machinery to environments in which strobe signals,including this strobe,are activated. or music appliances that may prevent alert persons from hearing the alarm.The horn The signal strobe cannot operate from coded power supplies.Coded power supplies may not be heard by persons who are hearing impaired. produce interrupted power.The strobe must have an uninterrupted source of power in or- NOTE:Strobes must be powered continuously for horn operation. der to operate correctly.System Sensor recommends that the horn and signal strobe always be used in combination so that the risks from any of the above limitations are minimized. FCC STATEMENT System Sensor Strobes and Horn/Strobes have been tested and found to comply with the can radiate radio frequency energy and,if not installed and used in accordance with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules.These limits are instruction manual,may cause harmful interference to radio communications.Operation designed to provide reasonable protection against harmful interference when the equip- of this equipment in a residential area is likely to cause harmful interference in which ment is operated in a commercial environment. This equipment generates,uses,and case the user will be required to correct the interference at his own expense. SUPPLEMENTAL INFORMATION For the latest Warranty information,please go to: VRE2. http://www.Zstemsensor.com/en-us/Documents/E56-4000.pddf For Limitations of Fire Alarm Systems,please go to:htto://www.systemsensor.com/en-us/Documents/I56-1558.E ; Speakers only:For the latest Important Assembly Information,please go to: ❑� ❑� =�4. ❑� + http://www.ZLstemsensoLcom/en-us/Documents/IS6-6556.pd Warranty Limitations of Speakers Only: Fire Alarm Systems Assembly Information System Sensor®is a registered trademark of Honeywell International,Inc. 4 I56-5846-002 02018 System Sensor. 10/02/2018 SYSTEM SENSOR' Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications . 1 � System Sensor L-Series audible visible notification products are rich with features guaranteed to cut — I � installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02-12/01/2017-Page 3 L-Series Specifications Arch itect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02•1 2101/2 01 7•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(rnA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92'diam. 2.5' 6(17 3 mm)diam. (175.77 mm) (64 mm)� (17 peror PA. u sia c o Q o 41) C O O O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box O m ® � p � p0p a� 0000 �Op A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information DescriptionModel Ceiling Horn Strobes Ceiling Strobes 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL I 2-Wire,Horn Strobe,White SCWL Strobe,White 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©2017 System Sensor. corn SENSOR® Phone: Ohio Avenue•St.Charles,IL 7-649 Prorcurre current product Itest [nonce innofthisd ensheet. Phone:800 SENSOR2•Fax:630 377-6495 or currentproduct information,including th01/201version of this data sheet. AVDS86a-02•12/01/2017 n L-Series Gamewell © INSSTRUUME� Indoor Horns, Strobes, by Honeywell and Horn Strobes Description Indoor Selectable-Output Horns, The L-Series audible visible notification products offer the Strobes, and Horn Strobes for most versatile and easy-to-use line of horns, strobes, and Wall Applications horn strobes in the industry. In addition, this product includes lower current draws and a modern aesthetic design which reduce installation times and maximize prof- its. The following devices offer a variety of design options, so that the L-Series can be used for any application requirement. • White and red plastic housings. • Standard and small footprint devices. • Plain, FIRE, and FUEGO-printed devices. Similar to the entire L-Series product line, the wall-mount < horns, strobes, and horn strobes include a variety of fea- tures that increase their application versatility while simpli- fying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox.These fea- tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To further simplify the installation and protect devices from Wall Horns/Hom Strobes construction damage, the L-Series uses a mounting plate Features for all standard and compact models that include an on- board shorting spring. This feature allows Installers to test Listed for wall mounting only. wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide Offers small profile devices for horns and horn strobes. range of application requirements using the following fea- Provides an automatic selection of 12 or 24-volt tures: operation at 15 and 30 candela. • Field-selectable candela settings. Supports a rotary switch for horn tone and two volume • Automatic selection of 12-or 24-volt operation. selections. • Rotary switch for horn tones with two volume selections. Produces horn rated at 88+dBA at 16 volts. L-Series Specifications Uses field-selectable candela settings on wall units: Architect/Engineer Specifications - 15 -30 -75 -95 General - 110 - 135 - 185 The L-Series standard horns, strobes,and horn strobes Includes a mounting plate for all standard and all com- shall mount to any of the following enclosures: pact wall units. • standard 2 x 4 x 1 7/8-inch backbox Contains a mounting plate with a shorting spring that • standard 4 x 4 x 1 1/2-inch backbox checks the wiring continuity before device installation. • 4-inch octagon backbox Features a plug-in design with minimal intrusion into the • double-gang backbox backbox. The L-Series compact products shall mount to a single- Designed with a tamper-resistant construction. gang 2 x 4 x 1 7/8-inch backbox. A universal mounting Built with an updated modern design. plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting Supports electrical compatibility with the existing plate shall be used for mounting wall compact models. SpectrAlert and the SpectrAlert Advance products. The notification appliance circuit wiring shall terminate at Compatible with System Sensor synchronization protocol. the universal mounting plate. Also, the L-Series products, when used with the Sync-Circuit, Module accessory, shall SIGNALING - be powered from a non-coded notification appliance circuit ()� output and shall operate on a nominal 12 or 24 volts. rM LISTED APPROVED _ PENDING ISO 900I GAMEWELL-FCI 031 LI S NTY YISTIM� 12 Clintonville UURL Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for insta➢ation purposes,and are subject to change wnthout notice.Nb responsibility is assumed by Gamewell-FCI for their use. C2016byttoneyweu International Inc. A lights reserved www.gamewell-fci.com 9021-60929 Rev.A page 1 of L-Series Specifications (Continued) Physical/Electrical Specifications Architect/Engineer Specifications (Continued) General (Continued) Standard Operating When it is used with the Sync-Circuit Module,the following Temperature: 32°F to 120°F(0°C to 49°C) occur: Humidity Range: 10 to 93%non-condensing • 12-volt-rated notification appliance circuit outputs shall Strobe Flash Rate: 1 flash per second operate between 8.5 and 17.5 volts. Nominal Voltage: Regulated 12 DC or • 24-volt-rated notification appliance circuit outputs shall regulated 24 DC/FWR1 operate between 16.5 and 33 volts. Operating Voltage Range2: 8 to 17.5 V(12 V nominal)or The Indoor L-Series products shall operate between 32 16 to 33 V(24 V nominal) and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn Operating Voltage Range strobes shall have the following field-selectable candela (MDL3)Sync Module: 8 .5 to 33 V to 17 V(12 V nominal)or 16 settings: • 15 30 75 95 (24 V nominal) • 110 135 185 Input Terminal Wire Gauge: 12 to 18 AWG Strobe Wall-Mount Dimensions The strobe shall be an L-Series Model listed to (including lens): 5.6 L x 4.7 W x 1.25 D(143 UL Standard 1971 and shall be approved for fire protective nunLx119mmWx32mmD) service. The strobe shall be wired as a primary-signaling Compact Wall-Mount Dimensions: 5.26"L x 3.46"W x 1.93"D notification appliance and comply with the Americans with (including lens) (133mmL08rrnnWx49mmD) Disabilities Act requirements for visible signaling appli- Horn Dimensions: 5.6 L x 4.7 W x 1.25 D(143 ances, flashing at 1 Hz over the strobe's entire operating mmLx119mmWx32mmD) voltage range. The strobe light shall consist of a xenon Compact Horn flash tube and associated lens/reflector system. Dimensions: 5.25"L x 3.45"W x 1.25"D Horn Strobe Combination Notes: (133mm L x 88mm W x 32mm D) The horn strobe shall be an L-Series Model listed 1. Full Wave Rectified(FWR)voltage is a non-regulated, to UL Standard 1971 and UL Standard 464 and shall be time-varying power source that is used on some approved for fire protective service. The horn strobe shall power supply and panel outputs. be wired as a primary-signaling notification appliance and 2. P, S, PC,and SC products will operate at 12 V comply with the Americans with Disabilities Act require- nominal only for 15 cd and 30 cd. ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audible options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a Sync-Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also,while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z(Class A)circuit.The module shall synchronize multiple zones. Daisy-chaining two or more synchroniza- tion modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 page 2 of 4 www.gamewell-fci.Com 9021-60929 Rev.A UL Current Draw Table 2 lists the UL maximum Horn current draw. Table 1 lists the UL maximum Strobe current draw. 8-17.5 8-17.5 Volts 16-33 Volts Sound Volts 16-33 Volts Candela DC DC FWR Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 Table 1: UL Maximum Strobe Current Draw(mA 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 RMS) 3.1 KHz Coded High 42 43 54 Table 2: UL Max. Horn Current Draw(mA RMS) UL Current Draw Data Table 3 lists the maximum UL Current Draw(mA RMS)allowed for 2-Wire Horn Strobes,candala range(15-115cd). 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 1156 153 173 1119 1140 1164 1190 1242 3.1 K Temp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1 k Cont Low 93 156 52 72 119 138 162 192 242 16V FWR FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 1 196 234 284 3.1 K Temp Low 68 90 145 166 186 1 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1 k Cont Low 77 102 1 156 177 199 234 1 291 Table 3: UL Max. Current Draw(mA RMS), 2-Wire Horn Strobe, Candela Range (15-115 cd) Horn Strobe Tones and Sound Output Data Table 4 lists the horn strobe tones and sound output data. 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 13.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 1 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Table 4: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA-Tel:(203)484-7161 -Fax:(203)484-7118 www.gamewell-fci.com 9021-60929 Rev.A page 3 of 4 L Series Dimensions L Series Dimensions 3A6 3.46 —1.25 1.25 6.2! 5.27 o1i �Ic 11111/1/111 fl--'+� 11111111111 11111111111 11111111111 I I�Ii 11 Figure 1 Compact Combo Figure 2 Compact Horn L Series Dimensions L Series Dimensions 4.70 4.70 1.91 1.91 1.25 1.25 & 7 5.67 f ' Figure 3 Standard Combo Figure 4 Standard Horn L-Series Ordering Information L-Series Ordering Information Wall Horn Strobes Horns Part Number Description Part Number Description P2RL 2-Wire, Standard Horn Strobe, Red HRL Standard Horn, Red P2WL 2-Wire, Standard Horn Strobe,White HWL Standard Horn,White P2GRL 2-Wire,Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Standard Horn Strobe,Red, Plain Accessories P2WL-P 2-Wire,Standard Horn Strobe,Wh ite,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Standard Horn Strobe,Red, TR-2W Universal Wall Trim Ring White FUEGO SBBRL Standard Wall Surface Mount Backbox, P2WL-SP 2-Wire, Standard Horn Strobe,White, Red FUEGO SBBWL Standard Wall Surface Mount Backbox, Wall Strobes White SRL Standard Strobe, Red SBBGRL Compact Wall Surface Mount Backbox, Red SWL Standard Strobe,White SGRL Compact Strobe, Red SBBGWL Compact Wall Surface Mount Backbox, White SGWL Compact Strobe,White Notes: SRL-P Standard Strobe, Red, Plain All-P models have a plain housing SWL-P Standard Strobe,White, Plain (no"FIRE"marking on cover). SRL-SP Standard Strobe, Red, FUEGO All-SP models have"FUEGO"marking on cover. SWL-CLR-ALERT Standard Strobe,White,ALERT All-ALERT models have"ALERT"marking on cover. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA-Tel:(203)484-7161 -Fax:(203)484-7118 page 4 of 4 www.gamewell-fci.com 9021-60929 Rev.A SYSTEM - �� SENSOR' �tll�tllt I'I'I'I'I oil F I I I I F ''t'''' Indoor Selectable- Output Horns R •, R , � Strobes ,, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut 46 •; - installation times and maximize profits with lower ` e' current draw and modern aesthetics. - Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications Arch itect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions 1.91' 3.46" 3.46" 48.5 mm 88 mm IIIIII��III�1.25' 3.57" 1.55" 88 mm 1.25' 32 mm (9.1 em) 3.9 cm) 32 mm I 0004001 W o 5.27„ °°rr°° 9°°°9°°°9°0°° 5.38' 133.9 mm 5.27" o°n°o°n°o°u°� (13.7 em) O 133.9 mm oao�nao�000ao nro�nro°n�o° C G� A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70' (11.94 cm) 1.91" 4.7" (4.85 cm) 1.25° 4.82„ 1.25" 119mm 32 mm (12.24 cm) (469 cm) (3.18 mm) 4 UP O ® O Zcm) 0 0 5.67" 0°0°0000°0578" O000.0 000 14( 144 mm °°°°°n0n0u0 0°0°0°0°04 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information DescriptionModel Description Model Wall Horn Strobes Horns* 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL I 2-Wire,Horn Strobe,White HWL* Horn,White ��2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SIP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St.Charles,IL 60174 ©2018SystemSensor SYSTEM . Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom SENSOR® www.systemsensor.com y for current product information,including the latest version of this data sheet. temsensor.com AVDS865-05.2/22/2018 Red for exterior notification devices - RAI SYSTEM SENSOR" Outdoor Selectable- Output Horns, H Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products �► o v a iN c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151 oF. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill O '0, holes for screw-in mounting.Plastic and metal weatherproof back L F M MEA boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch 7300-1653:137(outdoor strobes) LISTED sao11(eniLIS,LISTED strobes,Hems) APPROVED approved 7125-1653:16s(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horn.,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40oF to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with ,8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams �4.7 5.6- ° O 0 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box low 4 I si IIII �i� Red for exterior notification devices - RAI m -< A { Wall-Mount Horn Strobe with Plastic Weatherproof Back Box Spectr lert Advance Ordering Information DescriptionModel Wall Horo Strobes P2RK"t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P21FIH 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK-t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK't 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK`t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK`t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK"t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02012 System Sensor Y S . rJI 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12 Honeywell I Addressable Devices QGamewell Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti°Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern brightwhite color,the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations.The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series°and S3 Series panels support both the Velociti°and CLIP"protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotaryaddress Includes dual LEDs for Offers expanded color Standard 268 7th functional test switch switches(01-159) 3601visibility options Edition activated by external magnet • Supplies optional relay, • Designed with a new isolator,or sounder profile to offer modern • Supports a low standby bases(standard or low and improved current frequency) aesthetics Ordering Information Ordering Information NOTE:"-IV"suffix indicates Ivory color model. Accessories NOTE:"-BL'suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. ASD-PL3:Photoelectric smoke detector,bright white, TR300:Accessory Flange Ring for B300 6"Base,bright Velociti white ASD-PL3R:Photoelectric smoke detector,remote test TR300-IV:Accessory Flange Ring for B300 6"Base,ivory capable,for use with DNR(W)ductsmoke detectors,bright RA10OZ: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with B501 and B300-6. sensinq,bri ht white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,refer to Data Sheet M02-04-01: Detectortest magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR2B: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high B501-WHITE: 4"Flangeless mounting base,brightwhite ceiling applications. B501-WHITE-BP:4"Flangeless mounting base bulk pack, XP-4: Extension pole for XR2B.Shipped with three,5-foot bright white (1.524,m)sections. B501-IV: 4°Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,brightwhite B300-6-IV:6"Flanged mounting base,ivory B300-6-BP:6"Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,brightwhite B200SR-IV:Standard sounder base,ivory B20OS-WH:Intelligent addressable sounder base,bright white B20OS-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, brightwhite B200SR-LF-IV:Standard low frequency sounder base, ivory B20OS-LF-WH:Intelligent addressable low frequency sounder base,bright white B20OS-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white B224BI-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti° Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Photoelectric Intelligent Detector: The Velociti°Series 3 Photoelectric Detectors are certifications,please visit: Physical Specifications designed to comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3Series®,Velociti°and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI®are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of Honeywell Operating Temperature Range: approval agencies,or listing may be in process. International Inc. Photo:320 F to 122'F(0'C to 501 C) Consult factory for latest listing status. UL°is a registered trademark Photo in Duct Applications:-4°F to 1581 F I S2332 of Underwriter's Laboratories (-20°C to 700 C) FM:3023594 Inc. Photo with Thermal:32'F to 1001 F(0'C to 38'C) M EA FDNY:COA-219-02-E Vol.VI This document is not intended Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to be used for installation non-condensing ISO 9001 Certification purposes.We try to keep our Rate-of-Rise Detection:Responds to greater than product information up-to- 15°F/minute or 135°F(8.3°C/minute or 57°C date and accurate.We cannot Range: 0 to 4,000 ft/min cover all specific applications Air Velocity 9 or anticipate all requirements. (0 to 1219.2 m/min) All specifications aresubjectto Electrical Specifications change without notice. Voltage Range: 15 to 32 VDC Standby Current(@ 24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA @ 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti®Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0617 1 K 104/2018 Honeywell www.honeywell.com ©2018 Honeywell International Inc. Honeywell I Addressable Devices QGamewell MS-7 Series Manual Fire Alarm Pull Stations General The Gam ewe ll-FCI,MS-7 Series man ualfire alarm pull stations are available in a wide . variety of configurations.The pull stations comply with the Americans with Disabilities Act(ADA)5-lb.maximum pull force requirement.Operating instructions and Braille text are engraved in the handle.All pullstations include a key lock/resetwhich is keyed PUSH IN alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull PULL F�'SMVI stations. J, P U 01� 1 N MS-7AF elociti Addressable Station The MS-7AF Velociti`Series addressable station is a double action pull station J, designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the pull station causes its assigned address _ to register at the fire alarm control panel.The door contains an LED which flashes C green in normal condition and lights steady red when the station has been activated The station features screw terminals. MS-7 Series MS-7ASF Velociti Addressable Station The MS-7ASF Velociti®Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the station causes its assigned address to register at the control panel.The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.*The station features screw terminals. The Velociti®Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and focuses on the single device.The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels.It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations • The pull stations(MS- • Offers surface or semi- Includes a tumbler lock *Only the red LED is compatible with all 7LOB)are Listed for flush mounting fortest and reset keyed operative in panels that Gamewell-FCI analog outdoor applications alike with analog do not operate in Velociti addressable fire alarm • Shock and vibration addressable fire alarm mode controls • Complies with ADApull resistant controls force requirements • Conventional stations • Both single and double suitable for use with action pull stations any UL Listed control available panel MS-7S Single Action Station NYC-Plate The MS-7S single action pull station is used with The NYC-Plate provides the backplate for the manual conventional fire alarm control panels.It features a set pull station.(See Figure 1). of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station,with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities `L and Flex Series releasing systems.It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort Figure 1 NYC-Plate The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities Ordering Information and Flex Series releasing systems where system abort MS-7:Double action station capabilities are required.It consists of the following: MS-7AF**: elociti addressable double action station • An MS-7LR mounted on a plate with an abort switch MS-7ASF**:Velociti addressable single action station • LED indicators that signal system normal and MS-7S:Single action station,wire leads system activated status MS-7L0B Double Action Station(Listed for Outdoor MS-7SP:Double action station,English and Spanish Applications) instructions The MS-7LOB station must be mounted on a Model MS-7LR:Agent release station,dual-action SB-I/0 backbox.In retrofit applications,the pull MS-7LRA:Agent release station with abort switch, station is UL Listed for use with the WP-10 backbox.It LED indicators,dual-action is intended for use with conventional control panels MS-7L0B:Double action station,outdoor use and has a set of single pole contacts and screw (Includes SB-1/0-Indoor/outdoor use backbox) terminals. SB-I/O:Indoor/outdoor use backbackbox Mounting The MS-7 interior pull stations may be surface SB-10:Surface backbox mounted or semi-flush mounted on a standard BG12TR:Trim ring for semi-flush mount,plastic double-gang,or4-inch(10.2 cm)square electrical box. NY-PLATE:NYC backplate for manual pull station An optional trim ring(BG12TR)may also be used for semi-flush mounting. **For use with the Gamewell-FCI analog addressable control panels only. 2 MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all The MS-7 Series is designed to com wth the following compliance approvals and li h lli Material:Lexan° g p y g certifications,please visit: Contact Ratings:0.25 amps.C 30 VAC/VDC(resistive) standard: http://www.gamewell- Dimensions:5 5/8"H x 41/4"W x 1 1/4"D UL Standard:UL 864 9th Edition fci.com/en-US/ (14x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx 0 eratin Temperature: These listings and approvals apply to the modules LEXAN°is a registered MS-7AF,MS-7ASR 32o to 1200 F Moto 490 C) specified in this document.In some cases,certain trademark of GE Plastics,a (MS-7LOB):-30°to 150°F(-35°to 66°C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies,or listing may be in process. Company. UL:S2465 MS-7AF, S-7ASF):10to93%(non-condensing) Consult factory for latest listing status. Velociti°and Gamewell-FCI ):85% 5%C�86° 3.6°(30° 2°C) are registered trademarks of Alarm Current:.0030 amp.0.007 for LED FM:3023594 Honeywell International Inc. Supervisor Current: MEA FDNY:67-02-E Vol.VI . Y UL`is a registered trademark (MS-7AF,MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. This system meets NFPA requirements for operation at 0 7160-1703:0170 This document is not intended —49°C/32—120°F and at a relative humidity 93% 2% 7160-1703:0109 to be used for installation RH(noncondensing)at 32°C 2°C(90°F 3°F). ISO 9001 Certification purposes.We tryto keep our However,the useful life of the system's standby batteries product information up-to- and the electronic components may be adversely affected date and accurate.We cannot cover all specific applications by extreme temperature ranges and humidity. Therefore, or anticipate all requirements. it is recommended thatthis system and its peripherals be All specifications are subjectto installed in an environment with a normal room change without notice. temperature of 15—27°C/60—80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 H o n eywe I I www.honeywell.com ©2017 Honeywell International Inc. ­44q Honeywell I Addressable Devices QGameuvell Velociti Series°,AOM-20, Addressable Output Relay Control Module General The Gamewell-FCI Velociti®Series,addressable output relay control module(AOM- 2RF)allows a Gamewell-FCI analog addressable fire alarm control panel to switch <Y - discrete relay contacts by code command.The relay provides two isolated sets of Form-C contacts which transfer simultaneously.Circuit connections to the relay — — contacts are not supervised by the module. The Velociti'Series use a communication protocol that substantially increases the — speed of communication between the SLC devices and certain Gamewell-FCI analog ill "I addressable fire alarm control panels.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and concentrates on the single device.The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any AOM-2RF Gamewell-FCI analog addressable fire alarm control panel.The module contains a panel controlled LED.The AOM-2RF is designed to mount in a 4"(10.16 cm)square junction box 21/8"(5.53 cm)deep. Ordering Information AOM-2RF:Addressable output relay control module Table 1 lists the relay contact ratings. CURRENT MAXIMUM LOAD RATING VOLTAGE DESCRIPTION APPLICATION 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30VDC Inductive Coded (L/R=5ms) 1A 30VDC Inductive Coded (L/R=2ms) 0.5A 125 VAC Inductive Non-Coded (PF=.35) 0.7A 75VAC Inductive Non-Coded Table 1:Relay Contact Ratings FEATURES & BENEFITS • Listed under UL Provides visual rotary, Includes a bi-color LED Designed as a compact Note 1:Only the red LED Standard 864 decimal switch that flashes green size to allow easy is operative in panels that addressing(01-159) wheneverthe module is installation do not operate in Velociti • Offers two sets of Form addressed,and lights mode "C"contacts stead red upon p on *Note 2:Thebi-color LED activation* functionality is not available on the GWF-7075 panel. Velociti Series° AOM-2RF Technical Specifications SYSTEMS STANDARDS For a complete listing of all The Velociti Series°AOM-2RF is designed to l with compliance approvals and comply Supervisory Current:.000375 amps. g p y certifications,please visit: Alarm Current:.0065 amps. the following standard: http://www.gamewell- Operating Temperature:320 to 1200 F Moto 49'C) UL Standard:UL 864 9th Edition fci.com/en-US/ o AGENCY LISTINGS AND APPROVALS documentation/Pages/ Relative Humidity:l0 to 93/o relative humidity(non- Listings.aspx condensing) These listings and approvals apply to the modules Dimensions:41/2"H x 4"W x 1 1/4" Velocitil Series and Gamewell- specified in this document.In some cases,certain FCI®are registered trademarks (11.4 x 10.2 x 3.2 cm) modules or applications may not be listed by certain of Honeywell International Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies,or listing may be in process.Consult factory for latest listing status. UL®is a registered trademark This system meets NFPA requirements for operation at 0 of Underwriter's Laboratories —49°C/32-120°F and ata relative humidity 93% 2% UL:S1913 Inc. RH(noncondensing)at 32oC 20C(90OF 30F). FM:3023594 However,the useful life of the system's standby batteries MEA FDNY:219-02-E Vol.VI This document is not intended and the electronic components may be adversely affected CSFM:7300-1703:0102 to be used for installation by extreme temperature ranges and humidity. Therefore, purposes.We tryto keep our ISO 9001 Certification product information it is recommended thatthis system and its peripherals be installed in an environment with a normal room date and accurate.Wee cannot coverall specific applications temperature of 15—271C/60—801F. or anticipate all requirements. All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's Velociti Series°AOM-2RF and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0625 I H 108/18 H o n eywe I I www.honeywell.com ©2018 Honeywell international Inc. ' Functional RIB® !, ll� Devices, �nE. � (800)888-5538 sales(afunctionaldevices.com ® www.functionaidevices.com DRY CONTACT INPUT RELAY RIB01 BDOmp SPDT,Class 2 Dry R1801 B D C [air yl)RIR S C U� BS Contact Input,120 Vac Power Input .. M..�� E 1& LISTED Z—m. roa,.M C E AAUeN mq Org DAIAsIiG rmmn N/O gAM�nn4rAVx n.i ;. ieemx"`c 'u�1 IIIIRf 1 120 VacWht uwn��M�n>k 'r RoXB Yel l CONTROL Neutra C CIRCUIT 1ii11= Blu N/C Dry Contact Input Wht/Red Wht/Blu SPECIFICATIONS #Relays&Contact Type: One(1)SPDT Continuous Duty Coil Contact Ratings: Power Input: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 277 Vac 42 mA @ 120 Vac Operating Temperature: -30 to 140'F 1110 VA Pilot Duty @ 277 Vac Humidity Range: 5 to 95%(noncondensing) 770 VA Pilot Duty @ 120 Vac Operate Time: 1.8 Seconds 20 Amp Ballast @ 277 Vac Notes: Relay Status: LED On=Activated 16 Amp Electronic Ballast @ 277 Vac(N/O) •Dry Contact Input Operation: Dimensions: 2.30-x 3.20-x 1.80-with.50-NPT Nipple 10AmpTungsten @ 120Vac(N/O) Close White/Red wire to White/Blue wire to Wires: 16-,600V Rated 240 WattTungsten @ 120 Vac(N/Q activate relay.If more than one dry contact Approvals: UL Listed,UL916,C-UL,CE,ROHS 2 HP @ 277 Vac RIB®shares a single dry contact input, Housing Rating: UL Accepted for Use in Plenum,NEMA 1 1 HP @ 120Vac White/Blue must be common. Gold Flash: No Override Switch: No 20191121 Functional Functional Devices,Inc. Toll-free: (800)888-5538 Email: sates@functionaldevices.com RIB 101 Commerce Drive Office: (765) 883-5538 Website: www.functionaldevices.com Devices,Inc: Sharpsville,IN 46068 Fax: (765) 883-7505 TERMS AND CONDITIONS OF SALE 1. OFFER,GOVERNING PROVISIONS AND CANCELLATIONS:This document constitutes an offer or counter-offer that such Product was originally defective,then Seller will at its option repair or replace the product without by Functional Devices,Inc.or any of its affiliates("Seller")to sell various products as agreed by Seller("Products") charge upon prepaid delivery of such Product to Seller's facility with proof of date of purchase.Corrections to the buyer named on the reverse side ofthis document or in other applicable print or electronic documentation of such defects by repair to or supplying of replacements for defective parts shall constitute fulfillment of all ("Buyer")in accordance with these terms and conditions.This writing is not an acceptance of any offer made by obligations of Seller. Buyer.This offer or counter-offer is expressly conditioned upon Buyer's assent to these terms and conditions and no others.Buyer is deemed to have assented to these terms and conditions(including Seller's warranty)when the first Seller shall not be liable for loss,damage,or expense directly or indirectly caused from the failure of Products to ofthe following occurs:A.Buyer signs and delivers to Seller an acknowledgement copy of any of Seller's quotation, perform as expected. order acknowledgement or invoice forms;B.Buyer gives to Seller(orally or in writing)specifications of quantity and/ or type,assortments thereof,delivery dates,shipping instructions,instructions to bill,or the like as to all or any part EXCEPT AS SET FORTH HEREIN,SELLER DISCLAIMS ALL REPRESENTATIONS OR WARRANTIES OF ANY KIND ofthe Products;C.Buyer receives delivery of any of the Products;or,D.Buyer has otherwise assented to the terms WHATSOEVER,WHETHER EXPRESS,IMPLIED OR STATUTORY,INCLUDING,WITHOUT LIMITATION,ANY IMPLIED and conditions hereof. WARRANTIES OF MERCHANTABILITY,NON-INFRINGEMENT,FITNESS FOR A PARTICULAR PURPOSE OR ANY WAR- RANTY ARISI NG FROM A COURSE OF DEALING OR USAGE OF TRADE.NO PERSON(INCLUDING ANY AGENT,DEALER Where an attachment to this Agreement or separate document referencing this Agreement consists of a quotation, OR REPRESENTATIVE OF SELLER)IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTYCONCERNING the quotation remains open for acceptance for a period of thirty(30)days or such other period as specified in the PRODUCTS EXCEPT TO REFER BUYER TOTHIS AGREEMENT.BUYER WARRANTS THAT BUYER HAS NOT RELIED ON quotation.Seller hereby rejects any additional or different terms or provisions contained in any purchase order, ANY OTHER WARRANTIES OR REPRESENTATIONS CONCERN ING THE PRODUCTS OR THIS AGREEMENT. acknowledgment or other communication heretofore or hereafter received from Buyer.Seller's delivery of Products For warranty service,call factory for RA number and send such Product prepared with sales receipt to: does not constitute an assent to any terms proposed by Buyer.Except for an officer of Sel ler,no representative of FUNCTIONAL DEVICES,INC.,101 COMMERCE DRIVE,SHARPSVILLE,IN 46068. Seller has any authority to waive,alter,vary,amend,or add to the terms hereof.THESE TERMS AND CONDITIONS OF SALE CONSTITUTE THE ENTIRE AGREEMENT rAGREEMENT")BETWEEN SELLERAND BUYER WITH RESPECT 7, LIMITATION OF LIABILITY:SELLER WILL NOT BE LIABLE FOR ANY LOSS OF PROFIT,INTERRUPTION TO THE MATTERS ADDRESSED HEREIN. OF BUSINESS OR ANY OTHER SPECIAL,CONSEQUENTIAL OR INCIDENTAL DAMAGES SUFFERED OR SUSTAINED BY BUYER FOR ANY REASON.EXCEPT FOR CLAIMS OF DEATH OR PERSONAL INJURY,IN NO 2. PRICES:The prices for the Products are based on the terms and conditions herein,including the limitations of EVENT WILL SELLER'S AGGREGATE LIABILITY TO BUYER ARISING UNDER ORIN ANYWAY RELATED TO liability and warranties,and all such terms and conditions are material to the sale of the Products.In the event Seller THIS AGREEMENT FOR ANY REASON(INCLUDING,BUT NOT LIMITED TO,LIABILITY ARISING FROM NEG- fails to provide a price quote and/or terms prior to the acceptance ofthe order,Buyer will pay Seller's then-current list LIGENCE OR ON THE BASIS OF STRICT LIABILITY,OR OTHERWISE)EXCEED THE TOTALAMOUNT PAID BY price for such Products.All quotations and invoices show the net selling price of each item quoted.In the event ofa BUYER TO SELLER HEREUNDER FOR ANY PRODUCT GIVING RISE TO A CLAIM UNDER THIS AGREEMENT. mathematical error,the quoted price per Product governs. 8. RETURNS:Unless otherwise approved by Seller in writing in its sole discretion,except in the case of a 3. TERMS OF PAYMENT:Buyer will pay the fees specified in each invoice provided by Seller in United States non-conforming shipment or a warranty issue,Buyer may not return Products.If Seller approves the return of Dollars within thirty(30)calendar days after the invoice date unless otherwise agreed to in writing by an authorized Products pursuant to the preceding sentence,such returned Products must be returned within ninety(90)days representative of Seller.Any amount due under this Agreement that remains unpaid after its due date will bear from date of invoice and will be subject to a 25%restocking fee.In the event of a non-conforming shipment or interest from the date that such payment became delinquent until the date it is paid in full at the lower of 1.5%per a warranty issue,Buyer may return Products,but only if Buyer first:(a)provides notice to Seller as required in month,which equals an annual percentage rate of 18%,or the maximum rate permitted bylaw.Seller reserves the this Agreement,(b)obtains prior authorization from Seller,and(c)all Products or containers for which return is right to establish,revoke or modify credit terms for Buyer at anytime.No discounts are allowed unless otherwise properly authorized have been marked with a return authorization number supplied by Seller.Buyer will make agreed to in writing by an authorized representative of Seller.Buyer will pay any collection fees,legal fees,or court all returns via a traceable form such as Federal Express,UPS or insured mail and in resalable condition.Buyer costs incurred by Seller to collect past due amounts.No offsets or setoffs of payments due to Seller hereunder are will pay all return shipping charges and any other charges associated therewith. allowed with respect to any other agreement between the parties.Seller hereby retains a lien on the goods sold for unpaid purchase money as herein provided. 9. CANCELLATIONS:Cancellation or deferment of all or part of an order is subject to acceptance by the Seller. If accepted,any reduction in quantity of any item to less than 85%ofthe original item quantity is subject to 4. TAXES AND OTHER CHARGES:In addition to the prices quoted or invoiced,Buyer will pay any sales tax,excise a 15%cancellation charge.If an order cancellation is accepted,the Buyer will make delivery and pay for all tax,use tax,value added or consumption tax,customs duty(that is assessed on the delivery of Product(s)to a material manufactured and in stock or in process at time of notice for such order,and for any special materials destination outside ofthe U.S.A.),fee or charge of any nature whatsoever imposed by any governmental authority on orders for which the Seller must take delivery. on or measured by the transaction between Seller and Buyer.In the event Seller is required to pay any amount,Buyer will reimburse Seller therefore;or provide Seller,at the time the order is submitted,an exemption certificate or other 10. EXPORTS.Buyer agrees that it will comply with any and all U.S.Export Controls and will not pay for,resell, document acceptable to the authority imposing the same.Seller does not accept and will not pay any fines,penalties transfer or knowingly sell Products in violation of U.S.Export Controls.If Buyer resells Products within or exports or chargebacks from Buyer for any reason. Products to a country or region which imposes upon Seller and/or Buyer an obligation to fund or undertake reuse,recycling,composting,recovery of Products,or any similar obligation(e.g.,the European Union's Waste 5. DELIVERY,RISK OF LOSS,CLAIMS AND FORCE MAJEURE: Electrical and Electronic Equipment Directive,EC 2002/96/EC)(the"Obligations"),Buyer shall wholly under- A.All prices quoted for products are Ex-Works(Incoterms 2010)at a shipping facility determined by Seller,unless take the Obligations or duties and shall be entirely responsible for all associated costs therewith.Seller shall otherwise noted by Seller("Seller''sShipping Facility").Risk of loss or damage,and beneficial ownership,ofthe have no obligation to reimburse Buyer for execution ofthe Obligations.In the eventthat Seller is named in a Products are transferred to Buyer when the Products are made available to Buyer at Seller's Shipping Facility.All proceeding based upon the Obligations,Buyer shall indemnify,defend and hold Seller harmless from all actions delivery dates are approximate. related thereto,including all civil and governmental actions. B.Buyer will only make written claims to Seller for damages,shortages or other delivery errors within seven(7) 11. MISCELLANEOUS.This Agreement is governed by the laws of the State of Indiana,without giving effect calendar days after receipt of shipment.All Products received by Buyer,or Buyer's clients,customers,or agents,that to its conflict of laws principles.Buyer hereby irrevocably consents and submits to the exclusive jurisdiction and are not rejected within such time will be deemed accepted.Failure to provide such written notice constitutes a waiver venue of the state and federal courts in Marion County,Indiana.The United Nations Convention for Contracts of all such claims regarding such shipment by Buyer.Buyer will not revoke acceptance. for the International Sale of Goods is explicitly excluded.Each provision contained in this Agreement constitutes (.Seller is not liable for any damage as a result of any delay or failure to deliver due to any act of God,act of a separate and distinct provision severable from all other provisions.If any provision(or any part thereof)is Buyer,embargo or other governmental act,regulation or request,fire,accident,power outage,strike,civil unrest, unenforceable under or prohibited by any present orfuture law,then such provision(or part thereof)will be weather,slowdown or other labor difficulties,war,riot,act ofterrorism,delay in transportation,defaults of common amended,and is hereby amended,so as to be in compliance with such law,while preserving to the maximum carriers,inability to obtain necessary labor,materials or manufacturing facilities or,without limiting the foregoing, extent possible the intent ofthe original provision.Any provision(or part thereof)that cannot be so amended any other delays beyond Seller's control.Buyer's sole and exclusive remedy for any delays or for Seller's inability will be severed from this Agreement;and,all the remaining provisions ofthis Agreement will remain unim- to deliver Products for any reason,in each case,that persists for more than ninety(90)days,is to cancel the order paired.No modification,addition or deletion,or waiver of any rights under this Agreement is binding on a party pursuant to Seller's Order Policies and Guidelines available upon request. unless made in a non-preprinted agreement clearly understood by the parties to be a modification or waiver, and signed by a duly authorized representative of each party. 6. WARRANTY;DISCLAIMER.Products are warranted to be free from manufacturing defects under normal use and conditions for five(5)years(the"Warranty Period"). The warranty does not apply to:(a)Damage caused by accident,abuse,mishandling,or dropping;(b)Products which have been subjected to unauthorized repair,opened,or taken apart;(c)Products not used in accordance with direc- tions;(d)Damages exceeding the cost of such Product;and(e)Damages caused by lightning,water,or condensation. lfwarranty service is required during the Warranty Period,and ifexamination shall disclose to Seller's satisfaction F2700 2.1.2020 � - -p _ Gameweii Velociti Series - FIRE CONTROL INSTRUMENTS AMM- by Honeywell Description Addressable Monitor Module The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit(IDC)with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- - — - -- _ tacts may be made addressable when connected to the AMM-2F module. AM42F The Velociti® Series use a communication protocol that substantially increases the speed of communi- Features cation between the sensors and certain Gamewell- Compact size allows easy installation FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the Class B, Style B, initiating circuit devices in the group has a status change, the 40 Ohm line resistance for each initiating device circuit panel's microprocessor stops the group poll and Connects to any normally open dry contact device concentrates on the single device. The net effect is response speed up to five times greater than earlier Specifications designs. Supervisory Current: .000375 amps The AMM-2F module can be programmed to provide Alarm Current: .00060 amps a wide variety of input functions to the Gamewell-FCI Operating Temperature: 32'to 120' F (0'to 49' C) addressable series fire alarm control panels. It can Relative Humidity: 10 to 93% be identified as a manual station, heat detector, ple- (non-condensing) num detector, waterflow switch, tamper switch, N.O. End-of-Line Resistance:47K ohms contact, smoke detector, projected beam smoke Dimensions: 1.YLx2.5"Wx0.5"D detector, sub loop, remote zone, etc. It can also (3.3 x6.4 x 1.3 cm) serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- Ordering Information ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- Part Number Description port a maximum line resistance of up to 40 ohms AMM-2F Addressable monitor module,single allowing the use of linear heat detection devices. The circuit,Style B, Class B compact size facilitates the installation of the module inside manual stations, or mounting boxes of various An ISO 9001-2000 Company types of alarm initiating devices. SIGNALINGO FM N,: Velocih'V is a registered trademark of Honeywell International Ina �� INI EA UL®is a registered trademark of Underwriters laboratories Inc. - '-- LISTED APPROVED Approved S1949 3023594 227-03-EVOLIV 7300-1703:102 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.Nb responsibility is assumed by Gamewell-FCI for their use. G2011 FloneywwU International Inc. Allrightsreserved. www.gamewell-fci.com 9020-0626 Rev.D1 page 1 of 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS Honeywell Velociti® Series 3 � QGamewell ©INSIRVM�rS� ASD-PL3R and ASD-PL3R-IV 12 Clintonville Road Intelligent Photoelectric Smoke Sensor Northford,CT 06472-1653 Phone:203.484.7161;Fax:203.484.7118 with Remote Test Capability in Duct Applications www.gamewell-fci.com SPECIFICATIONS Operating Voltage Range: 15 to 32 VDC Operating Current @ 24 VDC: 200 uA(one communication every 5 seconds with green LED blink on communication) Maximum Alarm Current: 2 mA @ 24 VDC(one communication every 5 seconds with red LED solid on) Maximum Current: 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED solid on) Operating Humidity Range: 10%to 93%Relative Humidity,Non-condensing Operating Temperature Range: 320F to 1220F(0°C to 50°C),-4°F to 158°F(-20oC to 70°C)in duct applications Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.) Height: 2.0"(51 min)installed in B300-6 Base Diameter: 6.1-(155 min)installed in B300-6 Base;4.1"(104 min)installed in B501 Base Weight: 5.2 oz. (147 g) Isolator Load Rating: 0.0063* *Please refer to your isolator base/module manual for isolator calculation instructions. UL268A listed for Duct Applications Duct Applications: ASD-PL3R and ASD-PL3R-IV are listed for use in ducts. This sensor must be installed in compliance with the control panel system See Duct Smoke Detectors Applications Guide HVAG53 for details on pendant installation manual. The installation must meet the requirements of the Au- mount applications.NOTE:ASD-PL3R and ASD-PL3R-IV are also listed for use thority Having Jurisdiction(AHJ).Sensors offer maximum performance when inside DNR(W)duct smoke detectors. installed in compliance with the National Fire Protection Association(NFPA); WIRING GUIDE see NFPA 72. All wiring must be installed in compliance with the National Electrical Code, GENERAL DESCRIPTION applicable local codes,and any special requirements of the Authority Having Models ASD-PL3R and ASD-PL3R-IV are plug-in type smoke sensors that com- Jurisdiction.Proper wire gauges should be used.The installation wires should bines a photoelectronic sensing chamber with addressable-analog communi- be color-coded to limit wiring mistakes and ease system troubleshooting.Im- cations.When used in duct applications with a DNR(W),testing can be done proper connections will prevent a system from responding properly in the remotely using approved System Sensor test accessories,eliminating the need event of a fire. for a test coil.The sensors transmit an analog representation of smoke density Remove power from the communication line before installing sensors. over a communication line to a control panel. Rotary dial switches are pro- 1. Wire the sensor base(supplied separately)per the wiring diagram,Figure 2. vided for setting the sensor's address. 2. Set the desired address on the sensor address switches,see Figure 1. FIGURE 1.ROTARY ADDRESS SWITCHES: 3. Install the sensor into the sensor base.Push the sensor into the base while turning it clockwise to secure it in place. S5 6 7$ 94. After all sensors have been installed,apply power to the control panel and 4activate the communication line. 25. Test the sensor(s)as described in the TESTING section of this manual. 1 0 TENS ONES C0162-00 ACAl1TION Two LEDs on the sensor are controlled by the panel to indicate sensor status. Dust covers provide limited protection against airborne dust particles during An output is provided for connection to an optional remote LED annunciator shipping.Dust covers must be removed before the sensors can sense smoke. (P/N RA100Z). Remove sensors prior to heavy remodeling or construction. Note: Only System Sensor approved accessories may be used with the ASD-PL3R and ASD-PL3R-IV. FIGURE 2.WIRING DIAGRAM: Gamewell-FCI panels offer different features sets across different models.As a Remote CAUTION:Do not loop wire under result,certain features of the photoelectric sensors may be available on some Annunciator terminal 1 or 2. Break wire run to control panels,but not on others.ASD-PL3R will support only Velociti®Series supervise connections. protocol mode.ASD-PL3R-IV will support either Velociti or CLIP(Classic Loop Interface Protocol) mode.The possible features available if supported by the (+) control panel are: I I 1. The sensor's LEDs can operate in three ways—on,off,and blinking-and E m ++_ ++_ +� they can be set to red,green,or amber.This is controlled by the panel. ® �a ® ® �s 2. The remote output may be synchronized to the LED operation or con- 0 ®® I®® I trolled independent of the LEDs. N 0 3. Devices are point addressable up to 159 addresses. (-) I I Please refer to the operation manual for the UL listed control panel for specific ———————— -—————————— —_—_—_____p p p (-) ——— CLASS A OPTIONAL WIRING_ I operation. The ASD-PL3R and ASD-PL3R-IV require compatible addressable (+) —� C0129-10 communications to function properly.Connect these sensors to listed-compat- TAMPER-RESISTANCE ible control panels only. Models ASD-PL3R and ASD-PL3R-IV include atamper-resistant capability that SPACING prevents their removal from the base without the use of a tool. Refer to the Gamewell-FCI recommends spacing sensors in compliance with NFPA 72.In base manual for details on making use of this capability. low air flow applications with smooth ceilings, space sensors 30 feet apart TESTING (9.1 m). For specific information regarding sensor spacing, placement, and special applications,refer to NFPA 72 or the System Smoke Detector Applica- Before testing, notify the proper authorities that the system is undergoing tion Guide,available from Gamewell-FCI. maintenance, and will temporarily be out of service. Disable the system to prevent unwanted alarms. 1 I56-6536-001 09/23/2019 All sensors must be tested after installation and periodically thereafter.Test- S. Use a vacuum cleaner or compressed air to remove dust and debris from ing methods must satisfy the Authority Having Jurisdiction (AHJ). Sensors the sensing chamber. offer maximum performance when tested and maintained in compliance with 6. Reinstall the chamber cover/screen assembly by sliding the edge over the NFPA 72. sensing chamber.Turn until it is firmly in place. The sensor can be tested in the following ways: 7. Replace the cover using the LEDs to align the cover and then gently push- A. Functional:Magnet Test(P/N M02-04-01 or M02-09-00) ing it until it locks into place. This sensor can be functionally tested with a test magnet.The test magnet 8. Reinstall the detector. electronically simulates smoke in the sensing chamber,testing the sensor 9• Test the detector as described in TESTING. electronics and connections to the control panel. 10.Reconnect disabled circuits. 1. Hold the test magnet in the magnet test area as shown in Figure 3. ll. Notify the proper authorities that the system is back on line. 2. The sensor should alarm the panel. SPECIAL NOTE REGARDING SMOKE DETECTOR GUARDS TWo LEDs on the sensor are controlled by the panel to indicate sensor Smoke detectors are not to be used with detector guards unless the combina- status.Coded signals,transmitted from the panel,can cause the LEDs to tion has been evaluated and found suitable for that purpose. blink,latch on,or latch off.Refer to the control panel technical documen- FIGURE 3:FEATURES OF THE PHOTO DETECTOR tation for sensor LED status operation and expected delay to alarm. B. Smoke Entry Magnet Test\Sensitivity readings are available through the FACP.Refer to the manufac- Marker Base Alignment Notch turer's published instructions for proper use. q° Additionally,canned aerosol simulated smoke(canned smoke agent)may Gres°re be used for smoke entry testing of the smoke detector. Tested and ap- Base 86j° proved aerosol smoke products are: Alignment Notch LED Manufacturer Model Magnet Test Marker LED HSI Fire&Safety 25S,30S(PURCHECK) C2021-01 SDi SMOKE CENTURIAN, SOLOA4, FIGURE 4:CLEANING THE PHOTO DETECTOR SMOKESABRE,TRUTEST No Climb TESTIFIRE 2000 Sensor Cover When used properly,the canned smoke agent will cause the smoke detec- tor to go into alarm.Refer to the manufacturer's published instructions for Sensing Chamber Cover Cover and Screen proper use of the canned smoke agent. Removal Tabs Sensing Chamber ACAUTION Canned aerosol simulated smoke(canned smoke agent)formulas will vary by C2022-00 manufacturer. Misuse or overuse of these products may have long term ad- verse effects on the smoke detector.Consult the canned smoke agent manufac- SPECIAL APPLICATION turer's published instructions for any further warnings or caution statements. When configured at the fire alarm control panel,this detector is capable of op- erating in a special application mode such that it has a higher sensitivity than C. Remote Test. is normally allowed by UL 268 for areas where early warning is important.In ASD-PL3R and ASD-PL3R-IV can be remotely tested using the RTS151 or this mode,the detector does not comply with the Cooking Nuisance Smoke RTS151KEY test accessories.Refer to the DNR(W) manual for wiring dia- Test. Detectors (Sampling ports) set to the special application mode are not grams. Maximum test response time may be up to two communications suitable for use in areas where cooking appliances may be used. If cooking from the panel. appliances are used within the protected space,a normal application detector A sensor that fails any of these tests may need to be cleaned as described or normal application mode must be used for that area. under CLEANING,and retested.When testing is complete,restore the system Special application mode is not for general use and the detector may be more to normal operation and notify the proper authorities that the system is back prone to false alarms if used in unsuitable environments. While no list is in operation. all-inclusive,some examples of unsuitable environments for special applica- CLEANING tion mode are areas with airborne particulate or aerosols including sawing, Before removing the detector, notify the proper authorities that the smoke drilling, and grinding operations, textile or agricultural processing, or areas detector system is undergoing maintenance and will be temporarily out of With engines that are not vented to the outside.A complete list of aerosol and service. Disable the zone or system undergoing maintenance to prevent un- particulate sources is available in the Annex of NFPA 72. wanted alarms. Suitable environments for special application mode could include early warn- 1. Remove the sensor to be cleaned from the system. ing for hospitals,museums,assisted living and other areas that do not have 2. Remove the sensor cover by pressing firmly on each of the four removal airborne particulate or aerosols. tabs that hold the cover in place. Refer to the fire alarm control panel documentation for information on how to 3. Vacuum the screen carefully without removing it. If further cleaning is configure the detector for special application mode. required continue with Step 4,otherwise skip to Step 7. 4. Remove the chamber cover/screen assembly by pulling it straight out. Please refer to insert for the Limitations of Fire Alarm Systems FCC STATEMENT DEVICE AND SYSTEM SECURITY This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference, Before installing this product ensure that the and(2)this device must accept any interference received,including interference that may cause undesired operation. tamper seal on the packaging is present and NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits unbroken and the product has not been tampered are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio with since leaving the factory.Do not install this frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there product if there are any indications of tampering. is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, If there are any signs of tampering the product which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following should be returned to the point of purchase. measures: It is the responsibility of the system owner to -Reorient or relocate the receiving antenna. ensure that all system components,i.e.devices, -Increase the separation between the equipment and receiver. panels,wiring etc.,are adequately protected to -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. avoid tampering of the system that could result -Consult the dealer or an experienced radio/TV technician for help. in information disclosure,spoofing,and integrity This Class B digital apparatus complies with Canadian ICES-003. violation. Gamewell-FCI®and VelocitO are registered trademarks of Honeywell International,Inc.Testifire®is a registrered trademark of SDi,I.I.C. 2 I56-6536-001 ©2019 Gamewell-FCI.09/23/2019 �` InnovairFiefm_ Gamewe11 Series FIRE® ROL NSSTRRUUMEINM Duct Smoke by Honeywell Detector Accessories Description Notification and Test Accessories The InnovairFlex Series Duct Smoke Detector accessories SMOKE add functionality to the duct detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All Gamewell-FCI duct detectors and accessories are UL Listed. T � The following duct smoke detector accessories are avail- able %NONE=, • APA151 Piezo Annunciator T • MHR Mini-Horn, Red • MHW Mini-Horn,White • RA100Z/RA100ZA Remote Annunciator REmote Test Station • IRTS151KEYI Remote Test Station with Key • H162 Multi-Signaling Accessory • AOS Add-On Strobe InnovairFlex-Series Accessories • RTS2-AOS Multi-Signaling Accessory Features The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible APA151 piezo annunciator offers a new style and pro- alarm signal, a red LED to indicate alarm status, and a vides enhanced audible alarm signals green LED to indicate power status. It is intended for use with Gamewell-FCI 4-wire conventional duct smoke detec- tor applications without a system control panel, to comply temporal and continuous tones for both high and low with NFPA 90A. volume settings The MHR and MHW SpectrAlert®Advance mini-horns fea- RA100Z and RA100ZA remote annunciators flexible ture temporal or continuous tones at high and low volume versatility are used for both conventional and intelligent settings. Their small footprint allows mounting to single- applications gang back boxes for applications where a small device is RTS151 an RTS151 KEY remote test stations are desired. designed to test duct detectors from remote locations The RA10OZ and RA10OZA remote annunciators are RTS2 and RTS2-AOS multi-signaling accessories are designed for both conventional and intelligent applications. used with the InnovairFlex 4-wire conventional duct Their red LED provides visual indication of an alarm condi- smoke detectors tion. The RTS151 an RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi- colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for An ISO 9000-2000 Company alarm. SIGNALING InnovairFlexT'and Sync-CircuitTA1 are trademarks and SpectraAlert0 is a registered trade- UL FM mark of Honeywell International Inc. LISTED - GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2009 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60532 Rev.A page 1 of 3 Description (Continued) Specifications, Duct Smoke Detector Accessories (Continued) The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional RTS151 Remote Test Station duct smoke detectors. These accessories include a key Power Requirements: Alarm LED:2.8 to 32 VDC, switch that can be used to select one of two connected 12 mA max. sensors to be tested, reset, or both by a push button Total Current: 105 mA max. switch.They also enable sensitivity measurements using Test Switch: 10 VA @ 32 VDC the SENS-RDR sensitivity reader (sold separately). The Reset Switch: 10 VA @ 32 VDC AOS (Add-On Strobe) is an optional accessory included Alarm Response Time: 40 seconds max. with the RTS2-AOS model. Temperature Range: -10°C to 60°C (14°F to 140°F) Relative Humidity: 95% non-condensing Specifications, Duct Smoke Detector Wire Gauge: 14 to 18 AWG Accessories Dimensions: 4.8"H x 2.90"W x 1.4"D APA151 Piezo Annunciator (12.1 H x 7.3 W x 3.5 D cm) Voltage: Regulated 24 VDC RTS15Peaqirements: emote Test Station with Key Operating Voltage: 16 to 33 VDC Power Power LED(Green): 14 to Maximum Alarm Current: 30 mA 35 VDC, 12 mA max. Temperature Range: 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 Relative Humidity: 10 to 93%non-condensing VDC, 12 mA max. Wire Gauge: 12 to 18 AWG Total Current: 105 mA max. Dimensions: 4.6"H x 2.9"W x .45"D Alarm Response Time: 40 seconds max. (11.6 H x 7.3 W x 1.1 D cm) Temperature Range: -10°C to 60°C (14°F to 140°F) MHR/MHW SpectrAlert@ Advance Mini-Horns Relative Humidity: 95% non-condensing Voltage: Regulated 12 DC or FWR Wire Gauge: 14 to 18 AWG (Full Wave Rectified)or Dimensions 4.6"H x 2.75"W x 1.8"D Regulated 24 VDC or FWR (11.6 H x 6.9 W x 4.5 D cm) Operating Voltage: 8 to 33 VDC(9 to 33 VDC with Sync-Circuit"' Module) Sounder Current Draw: 22 mA RMS max. RTS2 and RTS2-AOS Multi-signaling Accessory at 8 to 17.5 Volts DC Voltage: 20 to 29 VDC 17 mA RMS max. Power Requirements: at 8 to 17.5 Volts FWR Standby: 3.0 mA max. 29 mA RMS max. Trouble: 16.0 mA max. at 16 to 33 Volts DC 25 mA RMS max. Alarm without strobe: 30 mA max. at 16 to 33 Volts FWR Alarm with strobe: 55 mA max. Temperature Range: 0°C to 49°C(32°F to 120°F) Sounder: 85 dBA at ten feet Humidity Range 10 to 93%non-condensing Temperature Range: -10°C to 60°C(14°F to Nominal Sounder 140°F) Frequency: 3 kHz Relative Humidity: 95% non-condensing Wire Gauge: 12 to 18 AWG Wire Gauge: 14 to 22 AWG Dimensions 4.6"H x 2.9"W x 0.45"D Dimensions: 4.8"W x 5.3"H x 1.6"D (11.6 H x 7.3 W x 1.1 D cm) (12.1 W x 13.4 H x 4.0 D cm) For the very latest product specifications and listing infor- RA100Z/RA100ZA Remote Annunciator mation, please visit the Gamewell-FCI Web site at Voltage Range: Conventional System:3.1 to www.gamewell-fci.com. 32 VDC Intelligent System: 18to32VDC Maximum Alarm Current: 12 mA Dimensions: 4.6"H x 2.8"W x 1.3"D (11.6 H x 7.1 W x 3.3 D cm) GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60532 Rev.A page 2 of 3 www.gamewell-fci.com Accessories Gamewell-FCI provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation.As with our duct smoke detectors, all duct smoke detector accessories are UL Listed. SMOKE LMMA Figure 1 RTS151 UL S2522 Figure 2 RTS151KEY UL S2522 Figure 3 APA151 UL S4011 Figure 4 RTS2-AOS UL S2522 b -- VqPW Figure 8 RTS2-AOS with PS24LOW Figure 5 RA10OZ UL S2522 Figure 6 MHW UL S4011 Figure 7 MHR UL S4011 Strobe and PS12/24 LENSW lens Ordering Information Part Number Description Accessories Part Number Description Part Number Description APA151 Piezo Annunciator RTS151 KEY Remote test station with key lock MHR Mini Horn, Red RTS2 Multi-signaling accessory MHW Mini Horn,White AOS Add-On Strobe RA100Z/RA100ZA Remote annunciator alarm LED RTS2-AOS Multi-signaling accessory RTS151 Remote test station GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60532 Rev.A page 3 of 3 PWC North County Community Office PUD Fire Alarm Bldg C Job Number: 24339-C-1 24339-C-1 -PWC North County Community Office PUD Fire Alarm Bldg C PWC North County Community Office Table of Contents Spec # Section Manufacturer Doc Name Doc # Fire Alarm Gamewell - FCI SLP BLK 1 Space Age SS000685 2 System Sensor P2WL 3 System Sensor P2WK 4 Gamewell - FCI ASD PI-3 IV 5 Gamewell - FCI MS 7AF 6 Gamewell - FCI AMM 2F 7 Fire Alarm 0 _ Gamewell S3 Series E m 31 INSTRUMENTS control Control Panel by Honeywell Description Small Analog Addressable Fire Alarm Control Panel The Gamewell-FCI,S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high-end processing power. It offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks. r g r r r+ • Up to 64 nodes using the 7100 Series panel. `- • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ether- net connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. S3 Series The basic S3 Series consists of an SLP (Smart Loop Features Panel) main board, LCD-SLP touchscreen display, SLC Listed per ANSI/UL®Standard 864 9th Edition. loop personality modules, and 7 amp power supply. The IBC Seismic Certified. SLP provides either one or two SLC loops in Class A or B Allows one SLC loop(expandable to two loops)that configuration that supports either of the following protocols: supports either System Sensor or Apollo devices in • Up to 318 devices per loop using the System Sensor® Class A or Class B(Style 4,6 or 7). protocol. If you add a second loop module, it increases System Sensor supports up to 318 intelligent the maximum device count to 636 devices. devices and each SLC loop supports the following. • Up to 126 devices per loop using the Apollo protocol. If up to 159 detectors. you add a second loop module, it increases the maxi- up to 159 modules(expandable to 636 maximum mum device count to 252 devices. per panel). • Apollo supports up to 126 intelligent detectors and Four Class B or two Class A NACs can be wired and syn- modules per SLC.(Expandable to 252 maximum per chronized using the System Sensor, Cooper-Wheelock, or panel). Gentex strobes. To retrofit the SLP on the existing audible/ Includes a high resolution(4.3")(10.92 cm)color touch- visual appliances, the on-board Electronic EOL (EEOL) screen display. automatically adjusts to the EOL resistor in the field. Supports a network system of up to 122 nodes (includes E3 Series®panels)or up to 64 nodes A 4.3" (10.92 cm) color touchscreen display screen shows (includes 7100 Series). the following: Provides 7.0 amp power supply(120VAC or 240VAC). • Events on the system includes four Class B or two Class A built-in Notification • Status of analog addressable devices Appliance Circuits(NAC). Provides selectable System • Complete diagnostic fault codes/messages Sensor,Cooper-Wheelock,or Gentex strobe synchroni- zation.Five programmable function buttons with LED status for accessibility to the following functions: Supports up to 32 serial annunciators(LCD, LED only, LED Switch). -Disable/Enable -Trouble Acknowledge -Bypass Output -Alarm Acknowledge -Lamp Test -Custom-defined SIGNALING ® ® O �,- j�� City of E3 Se do nalinc.System Sensor and FocalPo nt®are registered trademarks of Honeywell int M EA r Chi-,. 0 �tatio FM - LISTED FD1 - Approved UL is registered trademark ofUnderwriters laboratories Inc. 51869 APPROVED COA-06#61627165.1703:0776 CIa55 1 Reference CertiRcate of Compliance VMA-45894-02C Is0 900 Som GAMEWELL-FCI OVAE LITY SYSTEMS 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for untomlation only,are not intended for installation purposes,and are subject to change without notice.Nb responsibility is assumed by Gamewell-FCI for theiruse. 52014byl>oneyw llInternationalInc. AD tights reserved. www.gamewell-fci.com 9021-60730 Rev.F page 1 of Application Features (Continued) The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the Offers an Ethernet port for programming,a variety of small to mid-sized buildings. Analog technology delivers system reports, and a FocalPointR Graphic Workstation the benefits of a simple system installation, while a user- connectivity. friendly interface makes panel operation and system main- Provides two fully-programmable Form-C contacts for tenance quick and intuitive. Fire,Trouble,and Supervisory. • TimeCap-Saves time and date up to 48 hours without Smart Panel Programming any power or battery. Using Boolean logic programming, the installer may cus- Automatically adjusts to any NAC End-of-Line Resistor tomize the system to precisely suit the needs of the build- (EOL)value(1 k-55k ohm)for legacy audible/visual ing owner. Auto-programming allows the installer to appliances. instantly locate all the devices on the SLC loop. Removable display can be used as a remote annunciator. Simple, Intuitive Display Suitable for pre-action deluge applications. The front panel display provides a user-friendly interface Optional Accessories for the operator's control. A 4.3" (10.922 cm) color touch- DACT-E3-Dialer screen displays system status, event details and service The Digital Alarm Communication Transmitter sends digital modes.On the front of the panel,six LEDs show the follow- signals over telephone lines to the central station. It con- ing conditions. nects to the SLP through an RS-485 bus. Using the Con- Fire Silenced tact ID format, the DACT-E3 provides a four-digit account • Hazard(Gas or CO) AC Power code followed by the code/numbers listed below: • Supervisory Trouble • Three-digit Event Code Five custom programmable switches allow the user quick Two-digit Group Number access to common functions specific to the building like Three-digit Contact Number device disable,output bypass and device status. All codes are used to provide specific point identification. Perfect for Retrofits The DACT-E3 is compatible with digital alarm communica- The S3 Series is well-suited for retrofit applications. The for receivers (DACRs) that receive the following signaling SLP provides a simple way to upgrade your fire protection formats: system. It is designed to be an upgrade solution for the leg- Contact ID SIA acy FCI 7100 and Gamewell 602 Series panels.An added 3+1 4+2 feature is the SLP's EEOL. Using EEOL, the installers can For more information, refer to the following data sheets: automatically identify the EOL for existing audible/visual DACT-E3 Data Sheet, P/N: 9020-0610 appliances. FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 Flexibility for Future Growth RPT-E3-UTP-Network Repeater Card The S3 Series can be expanded to add a second SLC loop The Network Repeater allows the SLP fire control panels to without replacing the entire system. Using the RPT-E3- connect to the broadband network from remote locations. It UTP Network Repeater, you can network up to 64 nodes connects to other networked units using unshielded, (122 nodes with the ANX node expander) using either twisted-pair wiring. The RPT-E3-UTP is available with two twisted-pair or fiber-optic. The built-in Ethernet port allows add-on fiber modules: the connection to the Gamewell-FCI's FocalPoint FML-E3 connects to the network using either 62.5/125 Graphical Workstation. micron multi-mode fiber. • FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100-Remote Annunciator The Remote serial display features an 80-character dis- play. The LCD-7100 can be surface or flush-mounted on a . . ■ . standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet,P/N:9020-0486. ASM-16-Addressable Switch/LED Module There are 16 programmable switches available to perform Figure 1 LCD-SLP Display any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g.ON, OFF,Activated,etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N:9020-0554. ANU-48-48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL®Listed annunciator enclosure. Up to 16 ANU-48 mod- ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N:9020-0596. GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.F page 2 of 4 www.gamewell-fci.com Figure 2 illustrates the SLP-BB Cabinet Enclosure. Specifications SLP-BB CABINET Device Loops Up to two Class A or B,System Sensor BACKBOX units,each loop supporting up to 318 device addresses. ® ' 2 Or- Apollo units,each loop supporting up SLP-BB CABINET ® to 126 device addresses per loop. OUTER R ® NAC circuits 4 Class B or 4 112 Class A(2.0 A each circuit), 6.0 A total NAC Operating Voltage 24 VDC "04-3 ® NAC Minimum Voltage 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit o Operating Voltage 24 V peak-to-peak ® Input Voltage 120 VAC,60 Hz a 240 VAC 50-60 Hz 2 0 201/8"H Input Current 120 VAC,2.75 amps max. 240 VAC, 1.4 amps max. Aux Power 1(Continuous) 24 VDC nominal at 1.OA Aux Power 2(Resettable) 24 VDC nominal at 1.OA • 0 1® ® Base Panel Current draw Standby:0.111 amps Alarm: 0.243 amps Operating Temperature 32e-120c F(0e-49e C) ® Relative Humidity 93%(non-condensing) Battery Charger Voltage +24 VDC Battery Charger 55 A/H batteries(cabinet 4112"D Capacity accommodates 12 A/H batteries) Alarm,Trouble& Supervisory Relay Contacts Form-C,2 amps @ 24VDC(resistive) Cabinet Dimensions: SLP-BB Dimensions 14 1/2"W x 20 1/8"H x 4 1/2"D Figure 2 SLP Enclosure (36.83 Wx 51.18 Hx 11.43 Dcm) S3BB-RB Dimensions 19 3/8"W x 19 3/8"H x 4.5"D (49.22 W x 49.22 H x 11.43 D) Supports up to 636 Velociti devices or252XP95 devices_ S3 Series Fire Alarm Control p� ' Panel R a - - MCS-COF Networkable up to 122 - Intenigent Duct Detector F.,IC,rbon Monoxide panels using twisted - / Detector pair wire or fiber optics. 0"0""r y I• a r+ ASD-PL2F ASD-LS Photo Detector Laser Detector A .T .. 1� AMM-21F A M-2 IF Mini Monitor Module Dual lnpuVOutput Motlule Local Energy 1\\ E3 Series, Trip Panel AOM-2RF MS-7AF 0 w EthernetDO _ Relay Module Pull Station N N LCD-7100 LCD-SLP LCD-E3 -n 2emote Annunicator Color ToucM1[creep Remote Annunicator 3 Annuni n 13 FocalPoint Workstation ASM-16 LANU�-48 Laptop LED Switch Control LED Display Driver Programming Figure 3 SLP Panel Configuration GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9021-60730 Rev.F page 3 of 4 Ordering Information Ordering Information (Continued) Part.WwAber Description Part Number Description SLIP-BILK SLP addressable FACP in black SLP-BB Accessories enclosure. DACT-E3 Digital Dialer Communicator Requires either an SLC-PM or an Transmitter for the S3 or E3 Series. SLC95-PM for SLC loops. LCD-SLP LCD Color Touchscreen display with SLP-RED SLP addressable FACP with red door five programmable switches. and black SLP-BB backbox. For use with the S3 Series panels. Requires either an SLC-PM or an Remote annunciation requires the E3 SLC95-PM for SLC loops. Series A2 cabinet. SLP-RED-G SLP addressable FACP (E3BB-BA2, E3BB-RA2) 240VAC power supply with red door and RPT-E3-UTP Network repeater card with twisted- black SLP-BB backbox. pair fiber connections require either an Requires either an SLC-PM or an FML-E3 or an FSL-E3 card. SLC95-PM for SLC loops. FML-E3 Multi-mode fiber-optic card for one SLC-PM System Sensor Loop Card- 1 loop used channel on the RPT-E3-UTP. for 159 sensors and 159 modules. FSL-E3 Single-mode fiber-optic card for one For use with the SLP-E3 panels only. channel on the RPT-E3-UTP. SLC95-PM Apollo Loop Card-1 loop used for 126 SLP-RB SLP motherboard sensors and modules. For use with the SLP-E3 panels only. For use with the replacement or the retrofit solutions. FLPS-7-1113 SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mount- ing plate. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM S3BB-RB SLP red cabinet with an inner door for the mounting display behind the plexiglass. Requires the following: • SLP-RB LCD-SLP • SLC-PM/ FLPS-7-RB SLC95-PM LCD-7100 Remote Serial LCD Annunciator ASM-16 Remote Programmable Addressable Switch/LED Module ANU-48 Remote LED Driver Module GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60730 Rev.F page 4 of 4 www.gamewell-fci.com j 0 S� S� Lm SIGNALING UL LISTED ];;;;;;;iii0"FAD ACE-11 FIRE ALARM DO CUM BUTS The FAD is the perfect fit to m eet the demanding E ALARM DOCUMENTS code requirem ents today. SAE's num ber one goal is to m anufacture code com pliant solutions and this Records Pr•• -ms Software product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firm\Aare version num bers shall be m antained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4G B USB flash drive it stores your fire alarm software safe and secure elim hating the occurrences of the soft- ware not being on site when technicians arrive to service the system .Along with your fire alarm soft- Standard Features: ware you can store your test & inspection docu- m ents, service records, m anuals &AS built drawings • Installed with a 4 gig digital flash drive for the system .Using a standard USB B connector it with USB B connector allows you to plug in with any standard SIB printer • 2 Key ring hooks to hold system keys cable to upload or download information. • B usiness card holder for key contacts • & erall Dim eisions are 12" x 13"tall and 2 1/4 deep The FDB is designed to hold critical m anuals and • 1 6 gauge steel box and cover for security documents with a durable steel retainer. It has • D urable powercoat baked on finish designated hooks to organize key rings and hold other colors available im portant business cards for easy access and • S tandard3/4'cat 30 key lock other lock w- reference. Inside the cover it has a organized note sem dies available table that allows for documentation for passwords • S olid stainless steel piano hinge and other critical system information. • P erm anently screened white ink 1" high "Fire Alarm Docum efts" • L egend sheet for passwords and system inform ation _ I �? ��/ �� ISO 9001 Space Age Electronics, Inc. [07] �r`III� REGISTERED www.Isae.com NFPA COMPANY 800.486.1723 Toll Free MEMER �,7 M cde In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, ED0549 L T10559 R ev.D 1/2 .lust Solutions! �SPACEAGE ELECTRONICS, INC. Specifications: The fire alarm docum efts box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be perm anently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 m cunting holes. Inside the enclosure will accom m adate standard 8 1/2 x 11 m anuals and loose docum Ent records that will be protected within the enclosure.A legend sheet will be perm aiently attached to the door for system required documentation, key contacts and system inform ation. The FAD will have securely m cunted inside a m him un of 4 G gabyte digital flash m eTt cry drive with a standard USB B connector for uploading and downloading inform ation. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to m cunt standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector is ,�a.,.m.xb,m,ob,.P,x awa,ara.,a> rya Property Information Mhin—Required Documentation(SIG FUN) Key Ring �� E"�r' d-0. Hooksan�, Certifications and Approvals - aam mi Z!System Installs Contractor: oxu 1�1 o,al.-1 «om eu/nxmn:xm.m:.x1.a re wn n Enn09m nu we a mm..or a mm d aw o.� 1o1 Business o ­,noAll ; �d�c,aroo� „nma,xa�.�mo, Card Holder 16.5 Authouty,Ha ving�unstli Jurisdiction:ion: 1.�poEc (o All-rpmc alp a� oh. Ph—x,Allch— All aatiro All `�♦ •i11, ��• o —_— +ouin E—o,u�.m anon �w..xn zs.eam vaa Equipment Informatlon oa•`°o(a"�"t,°a'""apu. „xo l spennae Eknnnka,irc.5 etnocsename a rg, no,sta a oaneann3 wxu.tsea.com LT10aCC Rev.'I Legend sheet for storing system inform ation including contacts,sign-off,maintenance & test inform ation,and alternate locations of additional records. O idering Inform ation: Part# D escription SS000685 Fire Alarm Storage Cabinet RED 7Free Space Age E SS000686 Custom screening w th your Logo www.lsae.co800.486.172 Check out our Infinity line eFAD single gang 2 Gig digital storage 508 4485.096 solutions (IAM EFAD) 508.485.4740ax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0549 L T10559 R ev.D 2'2 SYSTEM - �� SENSOR' �tll�tllt I'I'I'I'I oil F I I I I F ''t'''' Indoor Selectable- Output Horns R •, R , � Strobes ,, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut 46 •; - installation times and maximize profits with lower ` e' current draw and modern aesthetics. - Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications Arch itect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions 1.91' 3.46" 3.46" 48.5 mm 88 mm IIIIII��III�1.25' 3.57" 1.55" 88 mm 1.25' 32 mm (9.1 em) 3.9 cm) 32 mm I 0004001 W o 5.27„ °°rr°° 9°°°9°°°9°0°° 5.38' 133.9 mm 5.27" o°n°o°n°o°u°� (13.7 em) O 133.9 mm oao�nao�000ao nro�nro°n�o° C G� A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70' (11.94 cm) 1.91" 4.7" (4.85 cm) 1.25° 4.82„ 1.25" 119mm 32 mm (12.24 cm) (469 cm) (3.18 mm) 4 UP O ® O Zcm) 0 0 5.67" 0°0°0000°0578" O000.0 000 14( 144 mm °°°°°n0n0u0 0°0°0°0°04 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information DescriptionModel Description Model Wall Horn Strobes Horns* 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL I 2-Wire,Horn Strobe,White HWL* Horn,White ��2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SIP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. 3825 Ohio Avenue 9 St.Charles,IL 60174 ©2018SystemSensor SYSTEM . Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom SENSOR® www.systemsensor.com y for current product information,including the latest version of this data sheet. temsensor.com AVDS865-05.2/22/2018 Red for exterior notification devices - RAI SYSTEM SENSOR" Outdoor Selectable- Output Horns, H Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products �► o v a iN c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151 oF. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill O '0, holes for screw-in mounting.Plastic and metal weatherproof back L F M MEA boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch 7300-1653:137(outdoor strobes) LISTED sao11(eniLIS,LISTED strobes,Hems) APPROVED approved 7125-1653:16s(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horn.,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40oF to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with ,8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams �4.7 5.6" ° O 0 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box 4 I si IIII �i� I II S G A { Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information DescriptionModel Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK-t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK't 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK`t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK`t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK"t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: 'Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02012 System Sensor Y S . rJI 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12 Honeywell I Addressable Devices QGamewell Velociti" Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI,Velociti°Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance.Designed in a modern brightwhite color,the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations.The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel.The modern design and expanded color options support a variety of contemporary aesthetic demands.In addition,each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re-designed optical sensing Photoelectric Detector chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment.The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR(DNRW)duct smoke detector housing.The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations,service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility.Service models are designated by the-IV part number after the detector model. Note:Although the E3 Series°and S3 Series panels support both the Velociti°and CLIP"protocols,the GWF-7075 panel does not support the CLIP protocol.To obtain a complete list of panels that are listed to Velociti Series 3 detectors,refer to the Compatibility Addendum for Gamewell-FCI Manuals,P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL° • Contains a built-in • Provides rotaryaddress Includes dual LEDs for Offers expanded color Standard 268 7th functional test switch switches(01-159) 3601visibility options Edition activated by external magnet • Supplies optional relay, • Designed with a new isolator,or sounder profile to offer modern • Supports a low standby bases(standard or low and improved current frequency) aesthetics Ordering Information Ordering Information NOTE:"-IV"suffix indicates Ivory color model. Accessories NOTE:"-BL'suffix indicates Black color model. SMB600:Surface Mounting Kit(flanged) NOTE:"WH"suffix indicates Bright White color model. ASD-PL3:Photoelectric smoke detector,bright white, TR300:Accessory Flange Ring for B300 6"Base,bright Velociti white ASD-PL3R:Photoelectric smoke detector,remote test TR300-IV:Accessory Flange Ring for B300 6"Base,ivory capable,for use with DNR(W)ductsmoke detectors,bright RA10OZ: Remote LED annunciator,3-32 VDC white,Velociti The annunciator mounts to a U.S.single-gang electrical ASD-PTL3:Photoelectric smoke detector with thermal box.For use with B501 and B300-6. sensinq,bri ht white,Velociti CK300: Bright White detector kit(Pack of 10) ASD-PL3-IV Photoelectric smoke detector,ivory,Velociti/ CK300-IR: White,detector color kit for use with MCS-COF Series Detectors.(Pack of 10) ASD-PL3R-IV:Photoelectric smoke detector,remote test CK300-IV: Ivory,detector color kit.(Pack of 10) capable,for use with DNR(W)duct smoke detectors,ivory, CK300-IR-IV: Ivory,detector color kit for use with Velociti/CLIP MCSCOF Series detectors.(Pack of 10) ASD-PTL3-IV:Photoelectric smoke detector with thermal CK300-BL: Black detector kit.(Pack of 10) sensing,ivory,Velociti/CLIP CK300-IR-BI: Black,detector color kit for use with Intelligent Bases MCSCOF Series detectors.(Pack of 10) For details on intelligent bases,refer to Data Sheet M02-04-01: Detectortest magnet. P/N:9021-60540. M02-09-00: Test magnet with telescoping handle. Note:"IV"suffix indicates Flashscan and CLIP devices. XR2B: Detector removal tool.Allows the installation and/ "WH"suffix indicates bright white or removal of the detector heads from the bases in high B501-WHITE: 4"Flangeless mounting base,brightwhite ceiling applications. B501-WHITE-BP:4"Flangeless mounting base bulk pack, XP-4: Extension pole for XR2B.Shipped with three,5-foot bright white (1.524,m)sections. B501-IV: 4°Flangeless mounting base,ivory B300-6: 6"Flanged mounting base,brightwhite B300-6-IV:6"Flanged mounting base,ivory B300-6-BP:6"Flanged mounting base bulk(Pack of 10) B200SR-WH:Standard sounder base,brightwhite B200SR-IV:Standard sounder base,ivory B20OS-WH:Intelligent addressable sounder base,bright white B20OS-IV:Intelligent addressable sounder base,ivory B200SR-LF-WH:Standard low frequency sounder base, brightwhite B200SR-LF-IV:Standard low frequency sounder base, ivory B20OS-LF-WH:Intelligent addressable low frequency sounder base,bright white B20OS-LF-IV:Intelligent addressable low frequency sounder base,ivory B224RB-WH:Relay base,bright white B224RB-IV: Relay base,ivory B224BI-WH:Isolator base,bright white B224BI-IV: Isolator base,ivory DNR: Intelligent duct detector housing,non-relay DNRW: Intelligent duct detector housing,non-relay, watertight 2 Velociti° Series 3 Detectors Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and Photoelectric Intelligent Detector: The Velociti°Series 3 Photoelectric Detectors are certifications,please visit: Physical Specifications designed to comply with the following standard: http://www.gamewell- Height: 2.0 inches(51 mm)installed in B300-6 base UL Standard:UL 268 fci.com/en-US/ documentation/Pages/ Diameter: AGENCY LISTINGS AND APPROVALS Listings.aspx 6.1 inches(15.49 cm)installed in B300-6 base These listings and approvals apply to the modules E3Series®,Velociti°and 4 inches(10.16 cm)installed in B501 base specified in this document.In some cases,certain Gamewell-FCI®are registered Shipping Weight: 3.4 oz(96.4 g) modules or applications may not be listed by certain trademarks of Honeywell Operating Temperature Range: approval agencies,or listing may be in process. International Inc. Photo:320 F to 122'F(0'C to 501 C) Consult factory for latest listing status. UL°is a registered trademark Photo in Duct Applications:-4°F to 1581 F I S2332 of Underwriter's Laboratories (-20°C to 700 C) FM:3023594 Inc. Photo with Thermal:32'F to 1001 F(0'C to 38'C) M EA FDNY:COA-219-02-E Vol.VI This document is not intended Operating Humidity Range: 10%to 93% CSFM:7272-1703:0501 to be used for installation non-condensing ISO 9001 Certification purposes.We try to keep our Rate-of-Rise Detection:Responds to greater than product information up-to- 15°F/minute or 135°F(8.3°C/minute or 57°C date and accurate.We cannot Range: 0 to 4,000 ft/min cover all specific applications Air Velocity 9 or anticipate all requirements. (0 to 1219.2 m/min) All specifications aresubjectto Electrical Specifications change without notice. Voltage Range: 15 to 32 VDC Standby Current(@ 24 VDC): 200 UA(one communication every 5 seconds with green LED enabled) Max Alarm Current(max.): 2 mA @ 24 VDC(one communication every 5 seconds with red LED enabled) Max Current(max.): 4.5 mA @ 24 VDC(one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti®Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0617 1 K 104/2018 Honeywell www.honeywell.com ©2018 Honeywell International Inc. Honeywell I Addressable Devices QGamewell MS-7 Series Manual Fire Alarm Pull Stations General The Gam ewe ll-FCI,MS-7 Series man ualfire alarm pull stations are available in a wide . variety of configurations.The pull stations comply with the Americans with Disabilities Act(ADA)5-lb.maximum pull force requirement.Operating instructions and Braille text are engraved in the handle.All pullstations include a key lock/resetwhich is keyed PUSH IN alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull PULL F�'SMVI stations. J, P U 01� 1 N MS-7AF elociti Addressable Station The MS-7AF Velociti`Series addressable station is a double action pull station J, designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the pull station causes its assigned address _ to register at the fire alarm control panel.The door contains an LED which flashes C green in normal condition and lights steady red when the station has been activated The station features screw terminals. MS-7 Series MS-7ASF Velociti Addressable Station The MS-7ASF Velociti®Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels.Activation of the station causes its assigned address to register at the control panel.The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.*The station features screw terminals. The Velociti®Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a grouped fashion.If one of the devices in the group has a status change,the panel's microprocessor stops the group poll and focuses on the single device.The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels.It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations • The pull stations(MS- • Offers surface or semi- Includes a tumbler lock *Only the red LED is compatible with all 7LOB)are Listed for flush mounting fortest and reset keyed operative in panels that Gamewell-FCI analog outdoor applications alike with analog do not operate in Velociti addressable fire alarm • Shock and vibration addressable fire alarm mode controls • Complies with ADApull resistant controls force requirements • Conventional stations • Both single and double suitable for use with action pull stations any UL Listed control available panel MS-7S Single Action Station NYC-Plate The MS-7S single action pull station is used with The NYC-Plate provides the backplate for the manual conventional fire alarm control panels.It features a set pull station.(See Figure 1). of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station,with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities `L and Flex Series releasing systems.It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort Figure 1 NYC-Plate The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities Ordering Information and Flex Series releasing systems where system abort MS-7:Double action station capabilities are required.It consists of the following: MS-7AF**: elociti addressable double action station • An MS-7LR mounted on a plate with an abort switch MS-7ASF**:Velociti addressable single action station • LED indicators that signal system normal and MS-7S:Single action station,wire leads system activated status MS-7L0B Double Action Station(Listed for Outdoor MS-7SP:Double action station,English and Spanish Applications) instructions The MS-7LOB station must be mounted on a Model MS-7LR:Agent release station,dual-action SB-I/0 backbox.In retrofit applications,the pull MS-7LRA:Agent release station with abort switch, station is UL Listed for use with the WP-10 backbox.It LED indicators,dual-action is intended for use with conventional control panels MS-7L0B:Double action station,outdoor use and has a set of single pole contacts and screw (Includes SB-1/0-Indoor/outdoor use backbox) terminals. SB-I/O:Indoor/outdoor use backbackbox Mounting The MS-7 interior pull stations may be surface SB-10:Surface backbox mounted or semi-flush mounted on a standard BG12TR:Trim ring for semi-flush mount,plastic double-gang,or4-inch(10.2 cm)square electrical box. NY-PLATE:NYC backplate for manual pull station An optional trim ring(BG12TR)may also be used for semi-flush mounting. **For use with the Gamewell-FCI analog addressable control panels only. 2 MS-7 Series Technical Specifications SYSTEMS STANDARDS For a complete listing of all The MS-7 Series is designed to com wth the following compliance approvals and li h lli Material:Lexan° g p y g certifications,please visit: Contact Ratings:0.25 amps.C 30 VAC/VDC(resistive) standard: http://www.gamewell- Dimensions:5 5/8"H x 41/4"W x 1 1/4"D UL Standard:UL 864 9th Edition fci.com/en-US/ (14x 10.1 x 3.2 cm) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx 0 eratin Temperature: These listings and approvals apply to the modules LEXAN°is a registered MS-7AF,MS-7ASR 32o to 1200 F Moto 490 C) specified in this document.In some cases,certain trademark of GE Plastics,a (MS-7LOB):-30°to 150°F(-35°to 66°C) modules or applications may not be listed by certain subsidiary of General Electric Relative Humidity: approval agencies,or listing may be in process. Company. UL:S2465 MS-7AF, S-7ASF):10to93%(non-condensing) Consult factory for latest listing status. Velociti°and Gamewell-FCI ):85% 5%C�86° 3.6°(30° 2°C) are registered trademarks of Alarm Current:.0030 amp.0.007 for LED FM:3023594 Honeywell International Inc. Supervisor Current: MEA FDNY:67-02-E Vol.VI . Y UL`is a registered trademark (MS-7AF,MS-7ASF):.00030 amps. CSFM: of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES 7160-1703:0119 Inc. This system meets NFPA requirements for operation at 0 7160-1703:0170 This document is not intended —49°C/32—120°F and at a relative humidity 93% 2% 7160-1703:0109 to be used for installation RH(noncondensing)at 32°C 2°C(90°F 3°F). ISO 9001 Certification purposes.We tryto keep our However,the useful life of the system's standby batteries product information up-to- and the electronic components may be adversely affected date and accurate.We cannot cover all specific applications by extreme temperature ranges and humidity. Therefore, or anticipate all requirements. it is recommended thatthis system and its peripherals be All specifications are subjectto installed in an environment with a normal room change without notice. temperature of 15—27°C/60—80°F. For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford,CT 06472-1610 203.484.7161 9020-0616 1 F 1 11/17 H o n eywe I I www.honeywell.com ©2017 Honeywell International Inc. � - -p _ Gameweii Velociti Series - FIRE CONTROL INSTRUMENTS AMM- by Honeywell Description Addressable Monitor Module The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit(IDC)with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- - — - -- _ tacts may be made addressable when connected to the AMM-2F module. AM42F The Velociti® Series use a communication protocol that substantially increases the speed of communi- Features cation between the sensors and certain Gamewell- Compact size allows easy installation FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the Class B, Style B, initiating circuit devices in the group has a status change, the 40 Ohm line resistance for each initiating device circuit panel's microprocessor stops the group poll and Connects to any normally open dry contact device concentrates on the single device. The net effect is response speed up to five times greater than earlier Specifications designs. Supervisory Current: .000375 amps The AMM-2F module can be programmed to provide Alarm Current: .00060 amps a wide variety of input functions to the Gamewell-FCI Operating Temperature: 32'to 120' F (0'to 49' C) addressable series fire alarm control panels. It can Relative Humidity: 10 to 93% be identified as a manual station, heat detector, ple- (non-condensing) num detector, waterflow switch, tamper switch, N.O. End-of-Line Resistance:47K ohms contact, smoke detector, projected beam smoke Dimensions: 1.YLx2.5"Wx0.5"D detector, sub loop, remote zone, etc. It can also (3.3 x6.4 x 1.3 cm) serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- Ordering Information ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can sup- Part Number Description port a maximum line resistance of up to 40 ohms AMM-2F Addressable monitor module,single allowing the use of linear heat detection devices. The circuit,Style B, Class B compact size facilitates the installation of the module inside manual stations, or mounting boxes of various An ISO 9001-2000 Company types of alarm initiating devices. SIGNALINGO FM N,: Velocih'V is a registered trademark of Honeywell International Ina �� INI EA UL®is a registered trademark of Underwriters laboratories Inc. - '-- LISTED APPROVED Approved S1949 3023594 227-03-EVOLIV 7300-1703:102 GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.Nb responsibility is assumed by Gamewell-FCI for their use. G2011 FloneywwU International Inc. Allrightsreserved. www.gamewell-fci.com 9020-0626 Rev.D1 page 1 of 1 Table of Contents Spec # Section Manufacturer Doc Name Doc# 28.31.00 Fire Detection and Alarm 24339-PWC North County Community Office Bldg A 1 print 24339-PWC North County Community Office Bldg B 2 print 24339-PWC North County Community Office Bldg C 3 print 2 3 4 B 6 7 8 Firm Name and Address GENERAL SYSTEM NOTES TYPICAL MOUNTING HEIGHTS Verify device,model number,etc... DEVICE LEGEND Absco PANEL: is accurate and cross check MANUFACTURER MODEL NUMBER DESCRIPTION BACK BOX SYMBOL QUANTITY Solutions 1. THE FIRE ALARM CONTROL PANEL(FACE) IS TO BE MOUNTED TO THE FINISHED product data. SURFACE.THE TOP OF THE PANEL SHALL NOT EXCEED 6 FEET ABOVE CEILING WALL MOUNT CEILING MOUNT CEILING MOUNT FINISHED FLOOR SURFACE.A MINIMUM CLEARANCE OF 36"WORKING SPACE -STROBE -STROBE -SMOKE DETECTOR MEWELL-FCI E3 ADDRESSABLE FIRE ALARM CONTROL PANEL E3BB-BD/INCC FFACEPI 1 P.O. BOX 2246 A SHALL BE MAINTAINED. HORN STROBE ROBE -HORN STROBE -HEAT DEFECTOR NAG EXPANDER POWER O LYNNWOOD, WA 98036 _WPGAMEWEL U L - 4 O M PROVIDED NAC1 1 PH: 425.771.1166 2. THE SUPPLEMENTAL NOTIFICATION APPLIANCE CONTROL PANEL(SNAG) IS GAMEWELL-FCI 1100-0450 FIRE ALARM REMOTE ANNUNCIATOR IFFART 1 FAX: 425.771.442422 TO BE MOUNTED SURFACE, BESIDE THE FACE.THE TOP THE PANEL SHALL NOT EXCEED 6 FEET ABOVE FINISHED FLOOR SURFACE.A MINIMUM ��� Add$$0006$5 SPACE AGE PROVIDED FFADC1 1 www.O bscosolutions.com CLEARANCE OF 36"WORKING SPACE SHALL BE MAINTAINED. BY OTHERS BY OTHERS MEDIA CONVERTER PANEL BY OTHERS MCP 1 3. THE SNAG IS TO BE POWERED T THE SAME DEDICATED 120 VAC Confirm the MCP Project Name and Address CIRCUIT AS THE FACP. TWO CONDUCTORS CI 120 VAC, ONE CONDUCTOR SNAG is not listed in - - TO ISOLATED GROUND,20 AMP DEDICATED CIRCUIT.A HOUSE GROUND WILL requirement.What is it? 6 ZONE AGENT RELEASE, NOT BE ACCEPTABLE the device legend. GAMEWELL-FCI FLEX GF50fiR PROVIDED RCP 1 CONVENTIONAL CONTROL PANEL CONFROL MANUAL FARA O PENETRATEDR THE BOTTOM OF THE FACP NOR C-rLL BE PANEL PULL STATION SENSOR SCWL CEILING MOUNT ST E,WHITE DOUBLE GANG ® 9 L�DEVICES: F SYSTEM SENS PC2WL CEILING MOU ORN STROBE,WHITE DOUBLE GANG 11 L�1. ALL MANUAL PULL STATIONS SHALL HAVE THE TOP OF THE STATION AT 48 INCHES ABOVE THE FINISHED FLOOR. SYSTE NSOR EWE W MOUNT STROBE,WHITE DOUBLE GANG ® 13 O ^ so' so' 4s" so" Add Fiber Network �1 ) 2. ALL SIGNALING DEVICES SHALL HAVE THE BOTTOM OF THE DEVICE Card EM SENSOR P2WL ALL MOUM HORN STROBE,WHITE DOUBLE GANG 3 PLACED AT 80 INCHES ABOVE FINISHED FLOOR WITHIN THE SPACE, OR THE ALL MOUNT HORN STROBE,WHITE,OUTDOOR, B TOP OF THE DEVICE 6 INCHES BELOW THE CEILING,WHICHEVER IS LOWER. SYSTEM SENSOR P2WK INCLUDES BAG BOX PROVIDED �WP 1 " 3. THE AUDIBLE DEVICES SIGNAL SHALL BE SET TO THE TEMPORAL ` �' SETTING. Cellular WRY COLOR WNH B3G0-6-W GAMEWELL-FCI -PL3-IV ANALOG PHOTOELECIRONIC SENSOR,VELOCITI/CLIP/, 3300-6-IV/4SQR W/3-0 RING 07 4. ALL DEVICES ARE TO BE LOCATED PER THE DRAWINGS. FINISHED GAMEWELL-FCI ATD-L3-IV 00 FLOOR THERMAL SENSOR 135Fr,VELOCITI CLIP, B300-6-IV/4SQR W/3-0 RING Q 2 W 5. WHEN APPLICABLE,VERIFY WITH MECHANICAL CONTRACTOR THE Communicator WRY COLOR EXISTENCE AND LOCATION of ALL MOTORIZED SMOKE DAMPERS.THESE ARE GAMEWELL MS-7AF ADDRESSABLE DOUBLE ACTION PULL STATION DEEP 4-SOR ❑F 1 TO CDBE 120 VAC DEVICES FEW CIRCUITS AS POSSIBLE.THESE DEVICE CI — CIRCUITS ARE TO BE CONTROLLED D BY THE FACE THROUGH AN INTERFACING G ELL-FCI AOM-2RF ADDRESSABLE RELAY MODULE DEEP 4-SQR ® 8 RELAY. FUNCTIONAL O DEVICES INC. RIB0I BDC 120VAC DRY CONTACT INPUT INTERFACE RELAY DEEP 4-SOR 11 3 6. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR ALL LOCATIONS OF THE SPRINKLER WATERFLOW, DRY FLOW, HI/LO AIR,TAMPER SWITCHES GAMEWELL-FCI AMM-2F ADDRESSABLE MONITOR MODULE DEEP 4-SQR 0 7 AND PIV OR 0,S,A,Y VALVES. ANALOG PHOTOELECTRONIC SENSOR,REMOTE GAMEWELL-FCI ASD-PL3R-IV SURFACE � 3 7. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THE EXISTENCE TEST CAR W DNR BASE&HOUSING OF SPRINKLER HEAT TAPE.THIS HEAT TAPE SHALL BE MONITORED BY THE Where term"by others"is used,confirm the responsible party and GAMEWELL-FCI RTS151 KEY KEY OPERATED REMOTE TEST STATION SINGLE GANG 3 O M Z FACP AND SHALL REQUIRE AN APPROPRIATE RELAY THAT WILL PROVIDE verifythat a Will provide the service or installation as BY OTHERS BY OTHERS VALVE SUPERVISORY SWITCH BY OTHERS 2 �J l SUPERVISION FOR HEAT TAPE GROUND FAULTS AND LOSS OF PRIMARYp p O %1 E POWER. referenced. Revise the term"by others"to specify the responsible BY OTHERS BY OTHERS WATERFLOW SWITCH BY OTHERS A 2 LL � O 8. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THAT ALL party.TYP,ALL SHEETS APPLICABLE INTERSTITIAL CEILING,ATTIC,OR FLOOR SPACES ARE PROTECTED WITH SPRINKLER HEADS. O O 9. ALL SPRINKLER WATERFLOW ZONES SHALL BE NON-SILENCEABLE PER O CD U.L. 864.THE CONDITION MUST BE RETURNED TO A NORMAL CONDITION BEFORE THE FACP CAN BE SILENCED. WIRING: Provide alternate WIRE LEGEND CD means per o EDICA ED PHo E uN s o E IN TALLE B wN R To ANSMITTER. NFPA 72 Chapter 26.6.4 Provide Building L Construction Type ABSCO DESCRIPTION MANUFACTURER MODEL NUMBER MODEL NUMBER MODEL NUMBER � RISER DESIGNATION NON-PLENUM PLENUM BURIAL = O OR PLENUM RATED WIRE WHERE REQUIRED PER NEC). A 16/2 SOLID FPLR,NON-SHIELDED BY OTHERS BY OTHERS O 3. AUDIBLE/VISUAL CIRCUITS ARE TO HAVE AN END OF LINE RESISTOR B 14/2 SOLID FPLR,NON-SHIELDED BY OTHERS BY OTHERS O(ELR)AS APPROPRIATE WITH THE FACP/SNAG. C CAT5 ETHERNET BY OTHERS BY OTHERS D 4. THE DEFECTION COMMUNICATION LOOP IS TO BE 16 AWG TWISTED, ] /� O NON-SHIELDED, MID-CAP FPL WIRE. (RISER OR PLENUM RATED WIRE WHERE Provide Code vvv /I REQUIRED PER NEC). References 5. THE DETECTION COMMUNICATION LOOP DOES NOT REQUIRE AN ELF AT THE END OF THE CIRCUIT. 6. WIRE TO WEATHERPROOF DEVICES SHALL BE STUBBED OUT ONLY. GENERAL SYSTEM LEGEND LEGAL NOTICE: THE INFORMATION SURFACE WEATHERPROOF BACK BOXES SHALL BE PROVIDED WITH DEVICES. CONTAINED IN THIS DRAWING IS THE NOTIFICATION DEVICE ID INITIATING DEVICE ID WIRE ID ABBREVIATIONS SOLE PROPERTY OF ABSCO SOLUTIONS, 7. ALL FIRE ALARM WIRES ARE REQUIRED TO BE IDENTIFIED AND Provide a"Scope REFERENCE WIRE LEGEND-ABSCO DFSIGNANON INC.ANY REPRODUCTION IN PART OR IN APPROPRIATELY MARKED. E=EXISTING WHOLE WITHOUT THE WRITTEN of Work" ryt- 7DI N=NLw8. PER NEC, NO AC VOLTAGE WIRING OF ANY KIND SHALL BE RUN IN THE NOTIFlCATION RR=REMOVE&RELOCATE DEVICE PERMISSION OF ABSCO SOLUTIONS,INC. SAME CONDUIT OR RISER AS THE LOW VOLTAGE FIRE ALARM SYSTEM WIRING. CIRCUIT# VICE# WIRE ID QIY OF WIRE MULTIPLE TYPES/QTY W=WIRELESS IS PROHIBITED.PATENT RIGHTS(WHERE cd=CANDELA RATINGAPPLICABLE) COPYRIGHTS ANO ALL9. ALL JACKETED CABLE MUST INCLUDE A JACKET REMOVAL PULL STRING All panels shall be NOTIFICATION DEVICE# CE TYPE mA=MILLIAMPSOTHER PROPRIETARY RIGHTS ARE AS PART OF THE CABLE. interconnected b a fiber S"ENSOR C 2C 1 2C 2B I _ E X P R E S S L Y R E S E RV E D B Y y LOOP# i t �� ELR VOENDGOF LINE ABSCO SOLUTIONS, INC. 10. SHIELDED CABLE IS NOT AN ACCEPTABLE SUBSTITUTION FOR CABLE network. Fiber is shown on °M'a9uLE TFA=TO FLOOR ABOVE T P T OF THE DESCRIPT the design drawings but is not TFB=TO FLOOR BELOW Designer of Record_ E ENERAL: specifically listed In the KEN DAY specifications 283100. ABSCo SownoeS,INC. 1. ALL FIRE ALARM JUNCTION BOXES ARE TO BE PAINTED RED. 19023 36TH AVE W STE E PROJECT NOTES Add,"Transmit signal NNWOOD,WA 96036 2. ALL END OF LINE DEVICES SHALL HAVE AN IDENTIFYING E.O.L.STICKER PHONE:(425) 1-44266 FAX:(425)]771-112 AT THE E.O.L. LOCATION. •TECHNICIAN TO AS-BUILD DEVICE ADDRESSES system fiber network" EAVJL KEN.DAY®ABSCOSOWTIONS.COM �7 •AMBIENT TEMPERATURE 70'F IN ALL SPACES as shown on the NICET:IV#97083 3. ONLY CONDUCTORS INTENDED FOR TERMINATION TO THE SPECIFIC PANEL DETAIL — ROOM 125 PtevatorShuntPowerOff � — DEVICE ON AN GIVEN JUNCTION BOX SHALL BE LEFT OPEN FOR Am SOUND SOUND LEVEL>40DB IN ALL SPAC design drawings. TERMINATION IN THAT JUNCTION BOX. ALL OTHER CONDUCTORS SHALL PASS Add,"Elevator Firehat THROUGH, OR BE SPLICED THROUGH,THAT JUNCTION BOX. FINISHED CEILING Lamp". SMOKE DETECTOR Close Fire Damper WARRANTY QUENCE OE OPERATION ALL EQUIPMENT AND LABOR PROVIDED BY ABSCO SOLUTIONS, INC. HAS TO A WARRANTY OF ONE YEAR FROM DATE OF INVOICE. THIS WARRANTY TO SEC NOTIFICATION TO SLC Activated DEVICES DEVICES DEVICES EXCLUDES ALL COVERAGE FOR CONSEQUENTIAL DAMAGES,AND IS GIVEN IN Generel Tmnsmd Tmnsmlt LIEU OF ALL OTHER EXPRESS WARRANTIES OR IMPLIED WARRANTIES OF Ndification-Alerts Transmit Tmu F FITNESS, HABITABILITY, OR MERCHANTABILITY OTHERWISE PROVIDED UNDER Hom Hom Alarm Signals at 71A HVA 11 or emote El" eyped THE LAWS OF WASHINGTON. ANY WARRANTY WORK PERFORMED BY ABSCO 3/4"EMT TYP. 3/4°EMT TYP. NiDR D2YICe Stmbe«Stmbe Signals FACE KNO ecell Sbu A uncialor 1-10/03/22 Submittal Set AP SOLUTIONS, INC. DOES NOT EXTEND THE WARRANTY OF ONE YEAR FROM �11 ��1 4 THE DATE OF THE INVOICE. Smoke Detector X X THIS WARRANTY SHALL BE VOID IF A PERSON OR FIRM OTHER THAN 2 Rev.#-Dale Revision By ABSCO SOLUTIONS, INC. OR THE CONTRACTOR AUTHORIZED BY ABSCO 6' 3' Heel Detector X X SOLUTIONS, INC. PERFORMS OR RE-PERFORMS ANY WORK IDENTIFIED WITHIN 6"GUTTER FIRE ALARM DOCUMENT 6"GUTTER Manuel Pull Station X X X THE ORIGINAL SCOPE of THE WORK OF THE CONTRACT WITH ASSOC USE STORAGE DEVICE Duct Detector X X X Drawn By A.P. SOLUTIONS, INC. 1" EMT TYP. 1"EMT TYP. Room 114 Heat Detector x LEGAL NOTICE:THE INFORMATION CONTAINED IN THIS DRAWING IS THE Room Lobby Smoke x Checked By D.H. SOLE PROPERTY of ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART E3 - D SIZE CABINET HPF-PS10B NAC1 OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ASSOC SOLUTIONS, TO MEDIA C 112 Lobby Smoke X INC. IS PROHIBITED. PATENT RIGHTS WHERE APPLICABLE COPYRIGHTS AND OmtD CONNECTION TO ( ) CONVERTER PANEL om;D FA P la X x X Dale 09 28 22 ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ABSCO v®tD LOW AIR ZN03 / / SOLUTIONS, INC. (BY OTHERS) umro Add,"Elevator Shah c T bl x x TO PHONE LINES omtD CONNECTION TO O Smoke and Heat FACP Supemsmy X x Project Name PWC NORTH COMM OFFICE BY OTHERS omiDD RELEASING SOLENOID ( ) NGA � DeteCtOf". VaNe Supertisory X X TO FARA AB ASM-16 OUTPUT#1 Water Flout Alarm X X X VICINITY MAP Project"umber 24339 G a, FLEX OF506R System Type AGENT RELEASE Add"Preaction Panel CONTROL PANEL Alarm,trouble and FIRE ,�"•ram supervisory". ALARM Verification of"Campus Twws= ° I t 60' 60' Notification"is needed. Wide sheet N°me Current notification is"local LEGENDS, building only" This can be programmed I the network. DETAILS, TO 120VAC( OTHERS) FIRE ALARM TO 120VAC PLANS (BY OTHERS) x Sheet Number H c«�n pm�bmrt•° F001 FINISHED FLOOR SHEET 1 OF 4 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address FLEX GF506R ARCP BATTERY CALCULATIONS E3 FACP BATTERY CALCULATIONS NOTIFICATION CIRCUIT CALCULATIONS Absco Solutions �� PANEL TYPE-LOCATION HPF-PS10B NACI-LEVEL 1 37 P.O. BOX 2246 A Absco BATTERY STANDBY REQUREMENTS o bAbsco BATTERY STANDBYREQUREMENTS 10 A max.each cld.-10A Total LYNNWOOD, WA 98036 PSolutions SO'Ut'OnS PANEL CIRCUIT INFORMATION PH: 425.771.1166 JOB NAME:24339-PWC North County Community Office PUD 1-FA JOB NAME:24339-PWC North County Community Office PUD 7-FA 7 cN5 akailahle Total AMPS, 2.528 NOTIFICATIONCIRCUITN N7 N2 N3 N4 INS NIB N7 FAX: 425.771.4422 INIEGPAnCNnwTeMIONERSAN PFK)TECTS Standby Alarm ate, Alarm INlaaanoNnwTEnscXVFRSAw PrmTECTs Standby ANpp Standby pip TOTAL#OF DEVICES 12 13 10 2 www.obscosolutions.com 1902336h Awnue W,Suae E,Lynnwood.WA SBW6 currant Current Current current 19023 3611a Aeanue W,Suile E Lynnwood,WA 9MM anon Current Currcm Cement - - - Phene(425)771-1166 Pox(425)771-4422 Amps Amps MrR Amps Phma:(425)771-1166 Fec(425)771-4422 Amps Paps Anps Amps CURRENT DRAW 0.841 0.732 0.631 0.324 - - Project Name and Address OTY Motlal0 De¢.Iptlon Type Each Each Taal Total OlY MI Desodp0m type Each Each rota Total CIRCUIT SPARE CAPACITY 72% 76% 79% 89% 100% 100% 10D% 2 ASUPL.1-IV Analog phabelectrmic senso, IN 0.00012 0.0045 0.0001 0.009 1 Eliding Load 0.030 0_055 0.030 E055 WIFE GAUGE 14aag 14awg 14aag 14awg - - - W 1 R.GF506R 67me Agent Release Red.Camadond PAN 0.004 0.015 0.004 Q015 1 11000455 ASMi6 programable swish nodde PAN 0.011 0.011 0.011 0.011 VOLTAGE DROP% 5.5% 5.3% 5.0% 1.3% - - - 1 MIAOF MLN Module.10 Input module IN 0.0035 0.080 0.0015 0.0800 7 AM.42F Address shlmlur hbdule IN boom 01 D.0028 0.m42 8 AOM42RF Anareesable o,pdeaay antra AUK 0.0004 0.0065 0.003 01 VOLTAGE DROP 1.32 1.26 1.19 0.31 - - - 5 ASOVLIIV Analog phobzkptrenic senses, IN 0.0002 0I OAI01 0.0225 END aF LINE VOLTAGE 22.68 22.74 22.81 23.69 3 ASD-PL3R-IV Anaogphdo:kctrenicee serja- IN 0.0002 0.0045 0.0006 0.01M MAXIMUM WIRE LENGTH(FEET)1 250 275 300 150 - - - 2 ATD-L3-IV Thermal--135FT VdacifiICLIP, IN 0.0002 0.0045 01 01 L� 1 DACT--E3 D!lld AsmC-nicalen PAN 0.018 10.018 0.018 0.018 CD FhL-© Fberlap mob k-hLN mntle SLB 0.053 om 0.0530 00530. Insen Loop 1 ILI-MAF Addreental,douleac.- 11 Based PAN 0.000 D150 0.081 0.007 o w� B 1 MNGAF AdaessGaphicAmmeateull alen IN 0.000. 0.007 ow 0.007 HPF-PS10B NAC1 BATTERY CALCULATIONS 1 � Natwvk Graphic Annandato PAN o.ae1 0.054 o.oe4 0.0e4 1 RM9 NetSdo'69A Parer,%pply PAN 0.027 0.050 111 0..OW 1 Rar-E3-111P Newark Repeaa,Uinsmechetl PAN 0.013 0.013 oXh3 0.013 3 RIS75110=Y Key opened remote test sla8m,lest SUB 0.012 0-012 0.035 0.036 L T Absco BATTERY STANDBY REQUIREMENTS LI IQ-Solutions JOB NAME:24339-PWC North County Community Office PUD 1-FA O Q INTEGRATION THAT EMPOWERS AND PROTECTS Standby Alarm Standby Alarm O 19023 36th Avenue W,Sure E,Lynrlwood,WA 98036 Currant Current Current Current Phone:(425)771-1166 Fax(425)771-4422 Amps Amps Amps Amps QTy Model# CandNa Description Type Each Each Total Total 1 HPF-PS1oB 10 AMP NOTIFICATION POWER SUPPLY PAN 0.075 0.150 0.075 0.150 4 Tao Toth 0.0W90 0.0840 36 Tool Teas 0.36114 0.5782 13 SWL 15etl WALL MOUNT STROBE SIG 0.000 0.043 0.000 0.559 u l Z 3 SCWL 15ctl CEIUNGMCUNTSTROSE SIG 0.000 0.041 0.000 0.123 O C NOTES: fEXGF506RARCP NOTES: ©FRCP 4 P02WL 15cd CEIUNG MOUNT FIORN STROBE SIG 0.000 0.071 0.000 0.284v7ah Bamry Cepecdy 24v55al1 Battey Capacity 1 P2WL 15cd WALL MOUNT HORN STROBE SIG 0.000 0.054 0.000 0.054 Current Draw to Trip MCI 6 SCWL 30etl CEIUNGMOUNTSTROBE SIG 0.000 0.063 0.000 0.378 c L'sfed Under"Eeefing Current' r� 7 PC2WL 30cd CEILING MOUNT HORN STROBE SIG O.00D 0.080 0.000 0.630 1 P2WK 75cd WP WALL MCUNT HORN STROBE SIG 0.000 0.176 1 0.000 0.176 O O Taal Semen Current 0.006 TAW Slaaby: OASIS Taal Smnrby Gument 0.361 Total Stanrby: &66736 2 P2WL 11O cl WALL MOUNT HORN STROBE SIG 0.000 0.162 0.000 0.324 X standby hours needed: 24 +Total Norm 01 X standby hours needed: 2/ +Tamp Nem 0.048 37 Total Totals 1 0.075 2.678 Tome 0.18% Total: 0.197 Total:&6674 Total: 8.715 O ^ J Told alarm Cu- 0.OB4 X Dealing fad.: 1.2 Taal Nam Cument 0,578 X Damning factor: 1.2 NOTES: HPF-PS10B NP.C1-LEVEL 1 X fracton of hours needed: 0.W3 Teal Anp Hues NCNed 0236 X fraction of hours needed: 0.083 Total An 1-l1urs Nestled: 10.458 17ttery Capacity Toa: 0.007 BaosO,Rs N,eema2 7ah Total: 0.048 BI Requirement Mel, O � Total Standby Current: 0.075 Total Standby: 1.8 X standby hour,needed: 24 +Total Alarm 0.222 O D Total: 1.8 Total: 2.022 / /1 Total Alarm Current: 2.678 X Derating factor: 1.2 X frnetbn of hours needed: 0.093 Total Amp Flours Needed: 2.427 Total: 0.222 Battery Requirement 7ah LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS,INC. IS PROHIBITED.PATENT RIGHTS(WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE FIREALARM RISER EXPRESSLY RESERVED BY Il IIIVI RISER Il ABSCO SOLUTIONS, INC. Designer of Record E LEVEL 2 LEVEL 2 KEN DAY ABSCO SOLUTIONS,INC. Show FSD FLAG NOTE: 9023 36THLYNNWOOD,AVE WA 98036 E 1E] TO FIRE SMOKE DAMPER CONTROL PHONE:(425)771-1166 FAX:(425)771-4422 Show FSD AND SUPERVISORY CONNECTIONS. EMAIL:KEN.oAY4FABSCOSOLUTIONS.COM NICEf:IV W 97083 TO 120VAC TO 1 (BY OTHERS) (BY OTHERS) 1(�' TO HVAC TO HVAC /,(-,� SHUTDOWN SHUTDOWN r-A- • A ; A I -A- (2AA--- (2A A�AN4-2 B N4-1 8L1 M42 L1 M43 L1 M44 L1 M45 L1 M46 L1 M47Li S09 ELR. 0.324MA110c 1Ocd F I DOI DOI UNIT UNIT 1-10/03/22 Submittal Set AP LEVEL 2 I LEVEL 2 -------------------------------------------------------- LEVEL ----------------I---------------------------------------------------- LEVELI Rev.-Date Revision y I Connection of interface relay to FSD or 120VAC Drawn By A.P. N3- ELR. 0.63110 B B B B B B B B B N3-1 B i is unclear. TO 120VAC Checked By D.H. MAPlease vise if 30cd 15cd 15cd 15cd 30cd 15cd 30cd I Why two shunt intenttent is show FSD. 30cd 30cd 30cd Trouble Monitor I relays? (BY OTHERS) I TO HVAC Date 09/28/22 I SHUTDOWN l Project Name PWC NORTH COMM OFFICE N2-13 B B B B B B B B B B B B N2-1 B A A J A • A • A A A ----A-- I A A A I -A- R ELR. 0.732MA 1 L1 M41 2A Project Number 24339 30cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 30cd 30cd 30cd 15cd 15cd L1 M20 Li M32 L1 M33 L1 M34 Li M35 Li S01 L1 S02 L1 M36 PRIMARYA Li S03 L1 SO4 ERE B system TypeLi M37 ALTERNATEA L1 SOS CLA R�A�RL1 M38 FLASHING HATA DOAS-1 R E N1-12 B B B B B B B B B B B N1-1 B L1 M30 L1 M3 L1 M39 SHUNT TRIP UNIT ELR. 0.841 MA ELEVATOR Correct to Pre-Action , ALARM 15cd 15cd 30cd 15cd 15cd 15cd 75cd SHUNT System not an Agent 15cd 30cd 30cd 15cd 15cd WIR System AGENT RELEASING SYSTEM Sheet Name AB FARA F- COMMENT ONLY:The three buildings can be NOTIFICATION networked and programmed via"CamWorks" zrlaz Cellular A software to use a single UDACT for the campus. CIRCUIT & Communitactor r----0 A separate UDACT is currently designed for BATTERY B C (Y r� ZN01 each building.A second transmission means is CALCULATIONS, NAC1 FADC FACP MCP RCP required,Le Cellular. FIRE ALARM RISER 120VAC H TO NETWORK(BY OTHERS) (BY OTHERS) T ERS)IONTO Sheet Number TO PHONE LINE(BY OTHERS LOW AIR ZN03 TO 120VAC(BY OTHERS) CONNECTION TO RELEASING C O O SOLENOID OUTPUT#1 LEVEL 1 L----------------- LEVEL 1 SHEET 2 OF 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address a bsco Solutions P.O. BOX 2246 A LYNNWOOD, WA 98036 PH: 425.771.1 166 FAX: 425.771.4422 W W W.c bscosolutions.com C C.8 D J K Project Name and Address � I �J 0 TRACK FOR L� F F4RTITION 204' 3" I 24 ", i _v In CD e GNSHADc LLJ N FLAG NOTE: z N Adjust the 1[] TO FIRE SMOKE DAMPER CONTROL FIW background Color/line TIONS. / T weight so the floor �J 3'-0' plans are visible. Confirm:Elevator equipment CDn+ 19'-9 7fb room heat detector shall be Q Q Add Strobe in 119 located within 24 inches of the O 103 107 sprinkler head conf.Room / \ TYP Show FSD 30cd N2-13 30cd ELR. 0.732mA Z N3-10 2 n O ELR. 0.631 mA TO B u l (BY OTHERS)THERS) 10 TO HVAC SHUTDOWN B 119 O F1.7. o z CANOPY FOR 1 R A -- cd115 118 ODOAS-1 UNIT L1 M41 2A L1 M40 Per District,locate FARA here. D o N confirm acceptable by AHJ. L1 S05 15cd sr-1 B B B Q B 1os 15cd 112 1141504 1 A�LAS03 116 30cd 30cd 301 & 102 B 17 B 109 �R A R A R A• SHUNT TRIP L1 M39 121 O 113 B FLASHING HAT L1 M38 B 30cd 15cd ALTERNATE L1 M37 D �15cd 15cd 15cd PRIMARY L1 M36 CDFlo, 105 15cd B B 15cd B `� 100 X B 122 z A,B TO FACP- L A{2 T 15cd _ ROOM 125,LEVEL 1 T L1 S02 15cd B B N2-1 5 FAfiA LEGAL NOTICE: THE INFORMATION B D B SOLE APROPERTYTOF ABSCO I SOLUTIONS, 15cd NG B 15cd INC.ANY REPRODUCTION IN PART OR IN Add trouble monitor WHOLE WITHOUT THE WRITTEN 145 15cd PERMISSION OF ABSCO SOLUTIONS,INC. 135 1z4 for NAC1 131 130 Add Supervisory IS PROHIBITED.PATENT RIGHTS(WHERE 144 140 Module APPLICABLE) COPYRIGHTS AND ALL B N3 15cd B B 134 123 TO 120V OTHERS) OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY 30cd CTION TO AB SC0 SOLUTIONS, INC.30cd 141 Nt-12 B E—Low air is Supervisory 143 0 ELR. 0.841 mA B 132 129 15cd L1 M34 -2 LOW AIR ZN03 L1 S01 L1 M35 L1 M3 CONNECTION TO Designer of Record E B B L------- A— r------------------------------------- — 33=RELEASING SOLENOID KEN DAY ------------------------------------------- 2 A RCP OUTPUT#1 ABSCO SOLUTIONS,INC. 3ocd B TO FARA • A A 19023 36TH AVE W STE E 30cd 13s 136 30cd A,B FADC 1 125 Show Fiber Networ(c, LYNNWOOD,WA 98036 15cd 133 15cd NAC1 A A A to other builsdings PF°nxNe(izs 1ni 1_„2e6 6 1-1 EMAIL KEN.DAY®ABSCOSOLUTIONS.COM MCP 'Li M20 d NICET:IV W 97083 L1 30 B B 128 L1 31IMAMA WP 15cd A ELEVATOR A L A yTFA I SHUNT 142 B B B ZN01 2 b 7 30cd 30cd ZN02 Fire Alarm Contractor to confirm location I ( 13a 137 TOTOA120VNE(BY 0 HERS) B with Arlington Fire 126 TO PHONE LINE(BY OTHERS) F TO NETWORK(BY OTHERS) 8 SUNSHADE 1-10/03/22 Submittal Set AP T'F Rev.#-Date Revision By Drawn By A.P. Verify the Preaction Verify dedicated Checked By D.H. system is a single riser covering two exterior sprinkler bell Data 09/28/22 pre-action to be separate rooms. operated via Project Name PWC NORTH COMM OFFICE A B 0 C.9 dedicated detection G H K zones for each room Project Number 24339 G System Type LEVEL 1-FIRE ALARM PLAN aFIRE r SCALE: 1/8"=1'0" _—_ _—_ ALARM --------------- Cm El Sheet Name I J LEVEL 1 FIRE ALARM PLAN Sheet Number H KEYPLAN Tm C O SCALE: NTS SHEET 3 OF 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address a bsco Solutions P.O. BOX 2246 A LYNNWOOD, WA 98036 PH: 425.771.1 166 FAX: 425.771.4422 ^ W W W.a bscosolutions.com C C.8 D E Project Name and Address I� 154'-3" O LL 24' 0" 21'-10" 24' 0" 24'-0" ''. 36' S" O L� O LLJ B _ FLAG NOTE: z MMN 1[] TO FIRE SMOKE DAMPER CONTROL W AND SUPERVISORY CONNECTIONS. O T Add Note:Elevator O Top of Shaft detection O shall be accessible O from the outside of Adjust the background Color/line the elevator shaft. Z weight so the floor Add Note:Elevator _ _ _ plans are visible. \ shaft heat detector r H - shall be located within = O 24 inches of the sprinkler head - ST-1 110cd C) �J N4-2 ELR. 0.324mA CDC 200 O 2. t O � L1 S10 2( Moo Z D Show FSD L1 SO6(� 44-1 CD B 110cd 5 I T CHSE MECH TO 120VAC TO HVAC LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE ( ) SHUTDOWN SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN OTo O TO 120VAC 202 WHOLE WITHOUT THE WRITTEN c FUTURE MEWS SHUTDOWN 1 1 (BY OTHERS) ST-2 PERMISSION OF ABSCO SOLUTIONS,INC. —— RESTROOM A A L1 M46 A A A IS PROHIBITED.PATENT RIGHTS(WHERE L-------------- -- R — I �— R I ---------------, APPLICABLE) COPYRIGHTS AND ALL LI 147 2A L1 M45 2A Ll M44 A OTHER PROPRIETARY RIGHTS ARE L1 S07 D L1 SO6 D • L1 M EXPRESSLY RESERVED BY A ABSCO SOLUTIONS, INC. O FOR L1 M4 FUTURE WOMEN'S OFOR DOAS-3 UNIT A — Designer of Record E RESTROOM DOAS-2 UNIT L-- B KEN DAY TO Cl — ROOM 125, LEVEL 1 ABSCO SOLUTIONS,INC. 6 201 6 19023 36TH AVE W STE E WO OD,WA 98036 I ---— — — LYNN 9 PHONE:(425)771-1166 FAX:(425)771-4422 Verify location of the EMAIL:KEN.DAY®ABSCOSOLUTIONS.COM sprinkler riser. NICEr:IV#97083 I F 1-10/03/22 Submittal Set AP Rev.#—Date Revision By C C.9 F G H H.1 Drawn By A.P. Checked By D.H. Data 09/28/22 Project Name PWC NORTH COMM OFFICE Project Number 24339 system Type —J LEVEL 2-FIRE ALARM PLAN O r FIR E SCALE: 1/8"=1'0" _—_ _—_ ALARM --------------- Lm Sheet Name I J LEVEL 2 FIRE ALARM PLAN Sheet Number H KEYPLAN Tm C I O SCALE: NTS SHEET 4 OF 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ular Firm Name and Address GENERAL SYSTEM NOTES TYPICAL MOUNTING HEIGHTS PANEL DETAIL - LEVEL 1 mmunicator DEVICE LEGEND AbscO PANEL: FINISH;;�; MAN ER MODEL NUMBER DESCRIPTION BACK BOX SYMBOL QUANTITY RSolutions 1. THE FIRE ALARM CONTROL PANEL(FACP) IS TO BE MOUNTED TO THE FINISHED SURFACE.THE TOP OF THE PANEL SHALL NOT EXCEED 6 FEET ABOVE CEILING WALL MOUNT CEILING MOUNT CEILING MOUNT SMOKE DETECTOR m the MCPFNISHED FLOOR SURFACE.A MINIMUM CLEARANCE OF 36"WORKING SPACE -STROBE -STROBE -SMOKE DETECTOR ement.What is it? GAMEWELL-FCI SLP-BLK ADDRESSABLE FIRE ALARM CONTROL PANEL PROVIDED FACP 1 P.O. BOX 2246 A SHALL BE MAINTAINED. -WPRHORNR STROBE -HORN STROBE GAMEWELL- HPF-PS108 NAC EXPANDER POWER PROVIDED NAC1 1 LYNNW WA SUPPLY-24VDC 1n AMPS 98036 PH: 425.771.11 66 2. THE SUPPLEMENTAL NOTIFICATION APPLIANCE CONTROL PANEL(SNAG) IS TO SPACE AGE SS FIRE ALARM DOCUMENT CABINET PROVIDED TFADC1 1 FAX: 425.771.4422 TO BE MOUNTED SURFACE, BESIDE THE EACH.THE TOP OF THE PANEL TO SLC NOTIFICATION SHALL NOT EXCEED 6 FEET ABOVE FINISHED FLOOR SURFACE.A MINIMUM '�' DEVICES DEVICES Add Fi er Network BY OTHERS 0 E MEDIA CONVERTER PANEL BY OTHERS MCP I www.abscosolUtions.com CLEARANCE OF 36"WORKING SPACE SHALL BE MAINTAINED. Card 3. THE SNAG IS TO BE POWERED BY THE SAME DEDICATED 120 VAC SNAC is of listed Project Name and Address CIRCUIT AS THE EACH. TWO CONDUCTORS TO 120 VAC,ONE CONDUCTOR 3/4"EMT TYP.� SYSTEM SENSOR CENNG MOUNT STROBE,WHITE DOUBLE GANG X 3 the devic legend. ® J TO ISOLATED GROUND, 20 AMP DEDICATED CIRCUIT.A HOUSE GROUN NOT BE ACCEPTABLE. � SYSTEM SENSOR PC2WL CEILING MOUNT HORN STROBE,WHITE DOUBLE GANG + 4 CONTROL MANUAL 6° 3 4. NEITHER THE BOTTOM OF THE FACP NOR TH A�ALL PANEL PULL 6"GUTTER SYSTEM SENSOR SWL WALL MOUNT STROBE,WHITE DOUBLE GANG ® 5 PENETRATED. STATION 1"EMT TYP. 1"EMT TYP. SYSTEM SENSOR PZWL WALL MOUNT HORN STROBE,WHITE DOUBLE GANG 7 L�DEVICES: WALL MOUNT HORN STROBE,WHITE,OUTDOOR, 1. ALL MANUAL PULL STATIONS SHALL HAVE THE TOP OF THE STATION AT C HPF-PS10B NAC1 SYSTEM SENSOR P2WK INCLUDES BACKBOX PROVIDED Z<WP I L� 48 INCHES ABOVE THE FINISHED FLOOR. TO MEDIA O ^ 60" 60" 48" CONVERTER PANEL ITT ) 'YOS ANALOG PHOTOELCOLOR IC SENSOR,VELOCITI CUP, 2. ALL SIGNALING DEVICES SHALL HAVE THE BOTTOM OF THE DEVICE (BY OTHERS) GAMEWELL-FCI ASD-PL3-IV 8300-6-M/4SOR W/3-0 RING 1 IVORY COLOR WITH 8300-6-IV ^ B PLACED AT 80 INCHES ABOVE FINISHED FLOOR WITHIN THE SPACE,OR THE TO PHONE LINES - - - GAMEWELL-FCI MS-7AF ADDRESSABLE DOUBLE ACTION PULL STATION DEEP 4-SQR F 1 \ o `V TOP OF THE DEVICE 6 INCHES BELOW THE CEILING,WHICHEVER IS LOWER. p ❑ / (BY OTHERS) p®• ^ I 3. THE AUDIBLE DEVICES SIGNAL SHALL BE SET TO THE TEMPORAL GAMEWELL-FCI AOM-2RF ADDRESSABLE RELAY MODULE DEEP 4-SOR ® 4 ` V SETTING. FUNCTIONAL DEVICES INC. RIB0I BDC 120VAC DRY CONTACT INPUT INTERFACE RELAY DEEP 4-SQR ❑I 3 00 4. ALL DEVICES ARE TO BE LOCATED PER THE DRAWINGS. FINISHED GAMEWELL-FCI AMM-2F ADDRESSABLE MONITOR MODULE DEEP 4-SOR Q 2 Z 5. WHEN APPLICABLE,VERIFY WITH MECHANICAL CONTRACTOR THE ANPLOG PHOTOELECTRONIC SENSOR,REMOTE LJ EXISTENCE AND LOCATION OF ALL MOTORIZED SMOKE DAMPERS.THESE ARE SLP-BLK GAMEWELL-FCI ASD-PL3R-IV SURFACE � 3 O TO BE 120 VAC DEVICES ON AS FEW CIRCUITS AS POSSIBLE.THESE DEVICE TEST CAPABLE-HVAC W DNR BASE&HOUSING CIRCUITS ARE TO BE CONTROLLED BY THE FACP THROUGH AN INTERFACING GAMEWELL-FCI RTS151 KEY KEY OPERATED REMOTE TEST STATION SINGLE GANG �7 3 RELAY. O ® BY OTHERS BY OTHERS VALVE SUPERVISORY SWITCHQ BY OTHERS 1 6. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR ALL LOCATIONS 71 OF THE SPRINKLER WATERFLOW, DRY FLOW, HI/LO AIR,TAMPER SWITCHES 60" FIRE ALARM DOCUMENTS BY OTHERS BY OTHERS WATERFLOW SWITCH BY OTHERS ® 1 AND PIV OR 0,S,&Y VALVES. °b`7°rogi0"`7 mimre 7. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THE EXISTENCE OF SPRINKLER HEAT TAPE.THIS HEAT TAPE SHALL BE MONITORED BY THE FACP AND SHALL REQUIRE AN APPROPRIATE RELAY THAT WILL PROVIDE SUPERVISION FOR HEAT TAPE GROUND FAULTS AND LOSS OF PRIMARY V J�1 O POWER. = 8. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THAT ALL WIRE LEGEND / n APPLICABLE INTERSTITIAL CEILING,ATTIC,OR FLOOR SPACES ARE PROTECTED YV L V IV �/ f WITH SPRINKLER HEADS. 9. ALL SPRINKLER WATERFLOW ZONES SHALL BE NON-SILENCEABLE PER ABSCO DESCRIPTION MANUFACTURER MODEL NUMBER MODEL NUMBER MODEL NUMBER U.L.864.THE CONDITION MUST BE RETURNED TO A NORMAL CONDITION TO 120VAC(BY OTHERS) DE$IGNATIDN NON-PLENUM PLENUM BURIAL O z BEFORE THE FACP CAN BE SILENCED. Provide alternate A 16/2 SOLID FEUD,NON-SHIELDED BY OTHERS BY OTHERS WI transmission means per B 14/2 SOLID FPLR,NON-SHIELDED BY OTHERS BY OTHERS O I1 J NFPA 72 Chapter 26.6.4 N 1. TWO DEDICATED PHONE LINES TO BE INSTALLED BY OWNER TO C CAT5 ETH BY OTHERS BY OTHERS LL TR S ITTER. FINISH FLOOR 2. ALL AUDIBLE/VISUAL CIRCUITS ARE TO BE 14 AWG EEL WIRE. (RISER Q OR PLENUM RATED WIRE WHERE REQUIRED PER NEC). O 3. AUDIBLE/VISUAL CIRCUITS ARE TO HAVE AN END OF LINE RESISTOR (1/ (ELR)AS APPROPRIATE WITH THE FACP/SNAG. Where term"by others"is used,confirm the responsible party and GENERAL SYSTEM LEGEND L� D 4. THE DETECTION COMMUNICATION LOOP IS TO BE 16 AWG TWISTED, verify that party will provide the service or installation as (DNON-SHIELDED,MID-CAP FPL WIRE. (RISER OR PLENUM RATED WIRE WHERE referenced. Revise the term"by others"to specify the responsible NOTIFICATION DEVICE ID INITIATING DEVICE ID WIRE ID ABBREVIATIONS REQUIRED PER NEC). party.TYP,ALL SHEETS REFERENCE WIRE LEGEND-ABSCO DESIGNATION E=EXISTING 5. THE DETECTION COMMUNICATION LOOP DOES NOT REQUIRE AN ELR AT N1-5 7DEVICE N=NEW THE END OF THE CIRCUIT. NOTIFICATION RR=REMOVE&RELOCATE DEVICE CIRCUITS (j WIRE ID QTY OF WIRE MULTIPLE TYPES/QTY W=WIRELESS 6. WIRE TO WEATHERPROOF DEVICES SHALL BE STUBBED OUT ONLY. NOTIFICATION DEVCEy cd=CANDELA RATING SURFACE WEATHERPROOF BACK BOXES SHALL BE PROVIDED WITH DEVICES. CE TYPE 2C 2B mA=MILLIAMPS LEGAL NOTICE: THE INFORMATION °ENSOR 8 V=VOLTAGE CONTAINED IN THIS DRAWING IS THE 7. ALL FIRE ALARM WIRES ARE REQUIRED TO BE IDENTIFIED AND LOOP# "M"ODULE OUR=END OF LINE SOLE PROPERTY OF ABSCO SOLUTIONS, APPROPRIATELY MARKED. TFA�TO FLOOR ABOVE INC.ANY REPRODUCTION IN PART OR IN All panels Shall be TFB=TO FLOOR BELOW WE WITH THE WRITTEN PERMISSION OF ABSCO SOLUTIONS,INC. RI 8. PER NEC, NO VOLTAGE WIRING OF ANY KIND SHALL BE RUN IN THE interconnected by a fiber IS PROHIBITED.PATENT RIGHTS(WHERE SAME CONDUIT OR RISER AS THE LOW VOLTAGE FIRE ALARM SYSTEM WIRING. network as shown on design APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE 9. ALL JACKETED CABLE MUST INCLUDE A JACKET REMOVAL PULL drawings. Provide Building E X P R E S S L Y R E S E R V E D B Y AS PART OF THE CABLE. PROJECT NOTES Construction Type ABSCO SOLUTIONS, INC. 10. SHIELDED CABLE IS NOT AN ACCEPTA STITUTION FOR CABLE •TECHNICIAN TO AS-BUILD DEVICE ADDRESSES W SCRIPTION. •AMBIENT TEMPERATURE 707 IN ALL SPACES Designer of Record E GE E L: •AMBIENT SOUND LEVEL>40D6 IN ALL SPACES KEN DAY ABSCO SOLUTIONS,INC. 1. ALL FIRE ALARM JUNCTION BOXES ARE TO BE PAINTED RED. 19023 36TH AVE W STE E LYNNWOOD,WA 98036 2. ALL END OF LINE DEVICES SHALL HAVE AN IDENTIFYING E.O.L. STICKER PHONE:(425)771-1166FAX:(425)771-4422 AT THE E.O.L. LOCATION. Provide Code EMAIL:KEN.DAYGABSCOSOLUTIONS.COM 3. ONLY CONDUCTORS INTENDED FOR TERMINATION TO THE SPECIFIC References SEQUENCE OF OPERATIONS NICET:IV a 97083 DEVICE ON ANY GIVEN JUNCTION BOX SHALL BE LEFT OPEN FOR TERMINATION IN THAT JUNCTION BOX. ALL OTHER CONDUCTORS SHALL PASS THROUGH,OR BE SPLICED THROUGH,THAT JUNCTION BOX. Out urt AGtivated General Transmit Transmit Notification-Alarm Transmit Trouble Supervisory Provide a"Scope of Horn+Horn Alarm Signals at Signals atOWACWARRANTY Work" Alarm Device Strobe.Strobe Si nals FACP FACP ALL EQUIPMENT AND LABOR PROVIDED BY ABSCO SOLUTIONS,INC. HAS Smoke Detector X X A WARRANTY OF ONE YEAR FROM DATE OF INVOICE. THIS WARRANTY Manual Pull Station X X EXCLUDES ALL COVERAGE FOR CONSEQUENTIAL DAMAGES,AND IS GIVEN IN Duct Detector X LIEU OF ALL OTHER EXPRESS WARRANTIES OR IMPLIED WARRANTIES OF F FITNESS, HABITABILITY,OR MERCHANTABILITY OTHERWISE PROVIDED UNDER FACP Alarm X X THE LAWS OF WASHINGTON. ANY WARRANTY WORK PERFORMED BY ASSOC FACP Trouble X 1-09/29/22 Submittal Set AP SOLUTIONS, INC. DOES NOT EXTEND THE WARRANTY OF ONE YEAR FROM THE DATE OF THE INVOICE. FACP Supervisory Rev.#-Date Revision By THIS WARRANTY SHALL BE VOID IF A PERSON OR FIRM OTHER THAN ABSCO SOLUTIONS, INC.OR THE CONTRACTOR AUTHORIZED BY ABSCO Valve Supervisory X SOLUTIONS, INC. PERFORMS OR RE-PERFORMS ANY WORK IDENTIFIED WITHIN Water Flow Alarm X 7C Drawn By A.P. THE ORIGINAL SCOPE OF THE WORK OF THE CONTRACT WITH ABSCO SOLUTIONS, INC. LEGAL NOTICE:THE INFORMATION CONTAINED IN THIS DRAWING IS THE Checked By D.H. SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS, INC. IS PROHIBITED. PATENT RIGHTS(WHERE APPLICABLE)COPYRIGHTS AND HSLV Fan Shutdown Date 09/28/22 ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ASSOC SOLUTIONS, INC. Project Name PWC NORTH COMM OFFICE VICINITY MAP Project Number 24339 G System Type v am. Kp FIRE „ p •o. A,.,, w.p _ ALARM rueme cv-9 xwsr ra°aAn•,s�,.Q sQ: ' Sheet Nam V LEGENDS, V DETAILS, ,1EAnW<- FIRE ALARM taM�M.,o,o PLANS � m Sheet Number H N, a aIo FZ 0 01 SHEET 1 OF 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address Absco Solutions P.O. BOX 2246 A LYNNWOOD, WA 98036 PH: 425.771.1166 FAX: 425.771.4422 www.a bscosolutions.com SLP-BLK FACP BATTERY CALCULATIONS HPF-PS10B NAC1 BATTERY CALCULATIONS NOTIFICATION CIRCUIT CALCULATIONS Project Name and Add.... PANEL TYPE-LOCATION HPF-PS100 NAC1-LEVEL 1 20 Absco BATTERY STANDBY REQUIREMENTS Absco BATTERY STANDBY REQUIREMENTS 3.0 Ami each ckL-10A Total Solutions PANEL CIRCUIT INFORMATION JOB NAME:24339-PWC North Count'Community Office PUDr-FA .So1i1t1o113 JOB NAME:24339-PWC North County Community Office PUD1-FA 7cld's available Total AMPS, 1.772 L� NOTIFICATION CIRCUIT# NI N2 N3 N4 NS NB N7 INTEORATICN THAT EMPOWERS AND PROTECTS Staally Alarm Starchy Nam INTEGRATION THAT EMPOWERS AND PROTECTS Standby Alarm standby Alarm TOTAL#OF DEVICES 6 5 9 - - - - 19023 Man A ue W,Sude E.Lynnwmd,WA 9B016 Current current Current Current 19023 36th AVenue W,Suile E,Lynarmood,WA 98036 Current Current Current Current Rlane:(425)771.1166 Fac(425)7T1-4422 Anps Ares Amps Asps Phone:(425)771-1166 Fax(425)771-4422 Amps Amps Amps Amps CURRENT DRAW 0.662 0.510 0.600 - - - - O Ill CITY leads!IN Description Typa Each Each Total Total CITY model# candela Description Type Each Each Total Total CIRCUIT SPARE_CAPACITY 78% 83% 80% 100% 100% 100% 10D% LLI B 1 Eveang Load 0.030 0.055 0.030 0.055 1 HPF-PS10B 10 AMP NOT!FICATION POWER SUPPLY PAN 0.075 0.150 0.075 0.150 WIRE GAUGE 14axg 14avg 14aag - - o ` V 2 ANMI Addressable NM1 rxr Made IN 0.0004 0.0006 0.0008 0.0D12 5 SWL read WALL MOUNT STROBE SIG 0.000 0.043 0.000 0.215 VOLTAGE DROP% 3.9% 3.3% 3.1% 4 AOM23F Addressable ouputreley corral AID( 0.0004 Q0085 01 010280 1 SCWL 15cd CEILING MOUNTSTROBE SIG 0.000 0.041 0.000 0.041 VOLTAGE DROP 0.94 0.80 0.75 - - - - M 1 ASDPL31V Analog photaekctrono senso. IN 0.0002 0.0045 0.0D02 0.000.6 2 P2WL 15cd WALL MOUNT HORN STROBE SIG 0.000 0.054 0.000 0.108 W 3 ASD-K3RIV Analog phdoekironic senSR,rempYr IN 0.0002 0.0045 01 0.0135 2 SCWL 30cd CEILING MOUNT STROBE SIG 0.000 0.063 0.000 0.126 END OF LINE VOLTAGE 23.06 23.20 23.25 - - - - 1 DACT--E3 DgiWAWmComunlcaum PAW 0.018 Qm8 0.0180 Q0180 2 PC2WL Sold CEILING MOUNT HORN STROBE SIG 0.000 0.090 0.000 0.180 MAXIMl1M WIRELENGTH(FEET) 225 250 200 - _ _ `LJ 1 FM.-E3 Fiber lap mI-MAN made SIH 0,053 0.053 0.0530 0.0530 2 P2WL 30ctl WALL MOUNT HCRN STROBE SIG 0.000 0.074 0.000 0.148 1 MS-7AF Pdtressabk double action put$Man IN 0.0003 0.007 0.OD03 0.0070 2 P2WL 75cd WALL MOUNT HORN STROBE SIG 0.000 0.121 0.000 0.242 O 1 F8FE3-UIP Nei Repeater,Lhshidded PAN 0.013 0.013 0.0130 Q0130 1 P2WK 75cd WP WALL MOUM HGRN STROBE SIO 0.000 0.176 0.600 0.r78 � O 3 RTS151KEY Key aparatatlremota 4e9 station,tat SUB 0.012 0.012 0.03A0 0.0390 2 PC2WL rr5cd CEILING MOUNT HORN STROBE SIG 0.000 0.187 0.000 0.374 O 1 SLGPM SLP adden SLC ncdb PAN 0.014 0.014 0.0140 0.0140 1 P2WL Iload WALL MOUNT HCRN STROBE SIG 0.000 0.162 0.000 OA62 1 BLPBLK Snort bap penat PAN 0.111 0.243 0.1110 0.2430 20 Total Totab 0.075 1.822 / \ NOTES: HPF-PS1OB 11AC1-LEVEL 1 l\�1 24V 7ah Battery Capacity 0 C O 0 Total Standby Current: 0.075 Total Standby: 1.8 X standby hours needled: 24 'Total Alamo 0.160 0 TMaI: 1.8 Total: 1.960 O O Total Alarm Current: 1.922 X Derating factor: 1.2 19 Total TaW I.-E X fraction of hours needed: 0.083 Total Amp Fours Needed 2.351 O Total: 0.160 Battery Req me uirent 7ah NOTES: SLP-BLKFACP ,/ 24V 12M Batley Capecay Curram Dmx o nip NWC1 Lkkd under Meeting Current' O Total SWI Current 0.278 TOIN St or ty: 668208 X Meador hours neelad: 74 +Total Alarm 0.040 / (DB Total:6.6821 Task 6.722 Total Alarm Current 0.484 XDaralNq bclux 12 X lneon of hours needed: 0.083 Total Arty lours NI 8.067 Total: 0.040 Bfty Re¢irenat 12e1h LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS,INC. IS PROHIBITED.PATENT RIGHTS(WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY A B S C 0 SOLUTIONS, INC. Designer of Record F KEN DAY ABSCO SOLUTIONS,INC. 19023 36TH AVE W STE E LYNNWOOD,WA 98036 PHONE:(425)771-1166 F.:(425)7J1-4422 EMAIL N FIRE ALARM RISER N ICET:IV#9OONS.COM NoA QA C 0LU J083 LEVEL 1 LEVEL 1 FLAG NOTE: N3-1 [-L> TO FIRE SMOKE DAMPER CONTROL F N3-9 B B B B B B B B B Add"I"Interface SNOW FSD SNOW FSD AND SUPERVISORY CONNECTIONS. ELR. 0.600MA for fans Verify Five Fans Show FSD 1-09/29/22 Submittal Set AP 15cd 15cd 15cd 15cd 15cd 15cd 15cd 30cd 115cd i Rev.-Date Revision By A A Drawn By A.P. B B B B BF N2-5 L1 M3 Checked By D.H. ELR. 0.510MA TO HVAC TO HVAC TO HVAC Sold Sold 110cd 75cd SHUTDOWN SHUTDOWN SHUTDOWN Sold 0 ACTIVATE AND DISCONNECT Add Trouble MonitAr FOR TO 120VAC TO 120VAC TO 120VAC Date 09/28/22 for NAC1 THREE HSLV FANS (BY OTHERS) (BY OTHERS) (BY OTHERS) Project Name PWC NORTH COMM OFFICE B B B B B N1-1 B A A A A 1 A A 1 A A 1 A N1-6 4- - R ----------- R ------- R I ------- R I Project Number 24339 ELR. 0.662MA r L1 M41 2A L1 M43 2A L1 M45 2A Sold 15cd Sold 75cd 75cd L1 M20 L1 S01 L1 M40 L1 M42 L1 M44 L1 M46 115cd Wp D D D System Type G Cellular Lt S02 Lt S03 L1 SO4 C C I Communicator DOAS-1 UNIT FIR E I All panels shall be interconnected by ALARM NACi B FADC FACP C MCP drawings.network as shown on design Sheet Name NOTIFICATION CIRCUIT & TO NETWORK(BY OTHERS) BATTERY TO PHONE LINE(BY OTHERS) CALCULATIONS, FIRE ALARM RISER LEVEL 1 LEVEL 1 Sheet Number H 7 FZ002 SHEET 2 OF 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address a bsco Solutions 1 X 4 A * LYNNWOOD, WA 98036 PH: 425.771.1166 FAX: 425.771.4422 w .Obscosolutions.com rove e additional Adjust the xterior horn strobes background Color/line provide notification Project Name and Address weight so the floor r all of loading dock pi ns are visibl L�J FLAG NOTE: C� l� TO FIRE SMOKE DAMPER CONTROL L L AND SUPERVISORY CONNECTIONS. I L� O LJ B Z N B Show FSD B Z LJJ 15cd 1 15cd .B 15cd IIffI-I 30cd O TO 120VAC II U III II (BY OTHERS) r TO HVAC cd SHUTDOWN B I FO t L1 DOAS-1 UNIT L1 M41 R,AI .I 30cd LI. Z C Provide additional B L1 S02 I D� 1 B N2c5 ftt LO O e xterior horn strobes ELR. 0.51OmA per District comment 30cd 110cd k 0 ,._ 30cd ONi-6 6G B TO 120VAC ELR. 0.662mA U (BY OTHERS) - TO 120VAC O A - (BY OTHERS) I L_---------------- TO HVAC TO HVAC I B B SHUTDOWN A SHUTDOWN Q B1— t r--------------------- - LU W 15cd 75cd A Z Z O 15cd I- N3-9 N2-1 - R 0 ELR. 0.600mA L1 M43 2A 1 M44 t R A I Q ~ L� TO ACTIVATE AND DISCONNECT _ _ L1 :.) L1 M45 L1 M46 0 0 O p POWER AT SOURCE FOR . A 1- - L1 SO4 .� T E HSLV FANS I / J " R ----------� 15cd �- O- u Maa Show FSD B Q x Q x Five Fans? I Show"I"Interface Show FSD 15cd m Eo LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE (OTC' B II IN.ANY PERTY OF REPRODUCTION S REPRODUCTION IN PART OCO IRNN WH LE WRITTEN 8 8 I PERMISSION WITHOUT OF ABSCO TSOLUTONS,INC. IS PROHIBITED.PATENT RIGHTS(WHERE A PP AND ALL OTH ER LICABL P ROPR ETARIY COPYRIGHTS GHTS ARE EXPRESSLY RESERVED BY B B A B S C 0 SOLUTIONS, INC. 30Cd Design. of Record E t- A KENDAY ABSCO SOLUTIONS,INC. FF l� TN3-1 5Cd 9LYNNWOOD,AWA 98036 E PHONE:(425)771-1166 TO PHONE LINE(BY OTHERS) PADC F.:(425)771-4422_ EMAIL:KEN.DAY®AescosownoNS.COM TO NETWORK (BY OTHERS) MCP NAC1 C FACP B NICET:IV q 97083 f� B 8 TO 120VAC(BY OTHERS) L 115cd \A�A� L1 M20 75cd - L1 M30,�•�}A�rj L1 M31 A� B O O 99 0 1 B - �_. - _ Q Q F WPd 12'-0"KNOCK OUT Unable to verify W W location of mezzanine W W 1-09/29/22 sanmi with current drawings. _ = nol set AP Please provide separate plan of Provide notification U) CO Rev.f-Date Revision By Verify dedicated as needed at O O exteriors sprinkler bell fire alarm layout at mezzanine. f— P RAI mezzanine. Drawn By A.P. = S Checked By D.H. A C E �1 c Q Date os/zB/zz • Project Name PWC NORTH COMM OFFICE Project Number 24339 Fire Alarm Contractor to confirm location(s) syetem Type G of exterior horn strobe LEVEL 1-FIRE ALARM PLAN a ['=1 ALTAR M with Arlington Fire SCALE: 1/8"=1'0" RE Sheet Name I LEVEL 1 FIRE ALARM PLAN Sheet Number H KEYPLAN a C Z 1 O 1 SCALE: NTS SHEET 3 OF 3 1 2 3 4 5 6 7 8 1 1 2 1 3 1 4 1 5 6 7 1 8 GENERAL SYSTEM NOTES TYPICAL MOUNTING HEIGHTS PANEL DETAIL - ELEC ROOM 102 DEVICEFirm Name and Add.... LEGEND Absco PANEL: FINISHED cEluNc MANUFACTURER MODEL NUMBER DESCRIPTION BACK BOX SYMBOL QUANTITY Solutions1. THE FIRE ALARM CONTROL PANEL(FACP) IS TO BE MOUNTED TO THE FINISHED Confirm t e MCP R SURFACE.THE TOP OF THE PANEL SHALL NOT EXCEED 6 FEET ABOVE CEILING WALL MOUNT CEILING MOUNT SMOKE DETECTOR FINISHED FLOOR SURFACE.A MINIMUM CLEARANCE OF 36"WORKING SPACE -HORN STROBE -SMOKE DETECTOR requirem t.What IS It. GAMEWELL-FCI SUP-BLK ADDRESSABLE FIRE ALARM CONTROL PANEL PROVIDED FRCP P.O. BOX 2246 1 A SHALL BE MAINTAINED. -WP HORN STROBE SPACE AGE FIRE ALARM DOCUMENT CABINET PROVIDED FFA­D­C1 1 LYNNWOOD, WA 98036 k t Newor 2. THE SUPPLEMENTAL NOTIFICATION APPLIANCE CONTROL PANEL(SNAG) IS TO Add Fi r BY OTHERS MEDIA CONVERTER PANEL BY OTHERS MCP t PH: 425.771.11 66FAX: 425.771.4422 TO BE MOUNTED SURFACE, BESIDE THE FACP.THE TOP THE PANEL TO SILO NOION Card SHALL NOT EXCEED 6 FEET ABOVE FINISHED FLOOR SURFACE.A MINIMUM '�' DEVICES DEVICE DEVICES wwW.O bSCOSOutiOnS.COm CLEARANCE OF 36"WORKING SPACE SHALL BE MAINTAINED. SYSTEM SEN WALL MOUNT HORN STROBE,WHITE DOUBLE GANG l< 2 3. THE SNAC IS TO BE POWERED BY THE SAME DEDICATED 120 VAC Cellul Project Name and Address SNAC is of listed I 3 4 EMT TYR. WALL MOUNT FOR STROBE,WHITE,OUTDOOR, CIRCUIT AS THE EACH. TWO CONDUCTORS CI 12T.VAC,ONE CONDUCTOR / SYSTEM SENSOR P2WK INCLUDES BACKBOX PROVIDED Z<WP 1 TO ISOLATED GROUND, 20 AMP DEDICATED CIRCUIT.A HOUSE GROUND WILL the devic legend. Comm nicator J NOT BE ACCEPTABLE. 2. CONTROL MANUAL ANALOG PHOTOELECTRONIC SENSOR,VELOCIP CDP, 4. NEITHER THE BOTTOM OF THE FACP NOR TH SNAC S LL BE PANEL GAMEWELL-FCI ASD-PL3-IV B300-6-N/450R W/3-0 RING 1 PENETRATED. PULL 6"GUTTER IVORY COLOR WITH B300-6-IV STATION GAMEWELL-FCI MS-7AF ADDRESSABLE DOUBLE ACTION PULL STATION DEEP 4-SOR ❑P 1 L�DEVICES: 1"EMT TYP. F GAMEWELL-FCI AMM-2F ADDRESSABLE MONITOR MODULE DEEP 4-SOR [] 2 1. ALL MANUAL PULL STATIONS SHALL HAVE THE TOP OF THE STATION AT L� 48 INCHES ABOVE THE FINISHED FLOOR. g0" 60" 48" C BY OTHERS BY OTHERS VALVE SUPERVISORY SWITCH BY OTHERS Q 1 O MEDIA O 2. ALL SIGNALING DEVICES SHALL HAVE THE BOTTOM OF THE DEVICE CONVERTER PANEL 4�S BY OTHERS BY OTHERS WATERFLOW SWITCH BY OTHERS ® 1 B PLACED AT 80 INCHES ABOVE FINISHED FLOOR WITHIN THE SPACE,OR THE _ LL--I N TOP OF THE DEVICE 6 INCHES BELOW THE CEILING,WHICHEVER IS LOWER. TO PHONE LINES \ o (BY OTHERS) p®• / N 3. THE AUDIBLE DEVICES SIGNAL SHALL BE SET TO THE TEMPORAL SETTING. 00 4. ALL DEVICES ARE TO BE LOCATED PER THE DRAWINGS. FINISHED W T FLOOR v) 5. WHEN APPLICABLE,VERIFY WITH MECHANICAL CONTRACTOR THE EXISTENCE AND LOCATION OF ALL MOTORIZED SMOKE DAMPERS.THESE ARE SLP-BLK WIRE LEGEND CI O /BE 120 VAC DEVICES FEW CIRCUITS AS POSSIBLE.THESE DEVICE - CIRCUITS ARE TO BE CONTROLLED D BY THE FACP THROUGH AN INTERFACING RELAY. ABSCO MODEL NUMBERMODEL NUMBERMODEL NUMBER 6. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR ALL LOCATIONS ® DESCRIPTION MANUFACTURER O OF THE SPRINKLER WATERFLOW, DRY FLOW, HI/LO AIR,TAMPER SWITCHES All panels shall be interconnected DESIGNATION NON-PLENUM PLENUM BURIAL 60" FIRE ALARM DOCUMENTS A 16/2 SOLID FPLR,NON-SHIELDED BY OTHERS BY OTHERS AND PIV OR 0,S,&Y VALVES. by a fiber network as St10Wn On "°'d A e09���°e'0'• 7. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THE EXISTENCE design drawings. B 14/2 SOLID FPLR,NON-SHIELDED BY OTHERS BY OTHERS _ OF SPRINKLER HEAT TAPE.THIS HEAT TAPE SHALL BE MONITORED BY THE C CAT5 ETHERNET BY OTHERS BY OTHERS Z FACP AND SHALL REQUIRE AN APPROPRIATE RELAY THAT WILL PROVIDE SUPERVISION FOR HEAT TAPE GROUND FAULTS AND LOSS OF PRIMARY V J�1 O POWER. = 8. WHEN APPLICABLE,VERIFY WITH SPRINKLER CONTRACTOR THAT ALL APPLICABLE INTERSTITIAL CEILING,ATTIC,OR FLOOR SPACES ARE PROTECTED WITH SPRINKLER HEADS. (` 9. ALL SPRINKLER WATERFLOW ZONES SHALL BE NON-SILENCEA13LE PER GENERAL SYSTEM LEGEND U.L.864.THE CONDITION MUST BE RETURNED TO A NORMAL CONDITION TO 120VAC(BY OTHERS) O O z BEFORE THE FACP CAN BE SILENCED. NOTIFICATION DEVICE ID INITIATING DEVICE ID WIRE ID ABBREVIATIONS Provide alternate REFERENCE WIRE LEGEND-ABSCO DESIGNATION E=EXISTING O WIRI : transmission means per N1-5 M1 N=NEW J 1. TWO DEDICATED PHONE LINES TO BE INSTALLED BY OWNER TO NFPA 72 Chapter 26.6.4 NOTIFICATION RR=REMOVE&RELOCATE DEVICE TR MITTER. FINISHED PLO CIRCUITS DEVICE(i WIRE ID Qtt OF WIRE MULTIPLE ttPES/QTY W=WIRELESS NOTIFICATION DEVICE, cd=CANDELA RATING DEVICE TYPE mA=MILLIAMPS 2. RISER C 2C 2C 2B "S"ENSOR �� �� �� V=VOLTAGE O OR PLENUM RATED WIRE WHERE REQUIRED PER NEC). LOOP# "M"ODULE ELR=END OF LINE 3. AUDIBLE/VISUAL CIRCUITS ARE TO HAVE AN END OF LINE RESISTOR Where term"b others'is used,confirm the responsible a and TFA=TO FLOOR ABOVE (ELR)AS APPROPRIATE WITH THE FACP/SNAC. y l p TFB=TO FLOOR BELOW verify that party will provide the service or installation as p 4. THE DETECTION COMMUNICATION LOOP IS TO BE 16 AWG TWISTED, referenced. Revise the term"by others"to specify the responsible / ^ O NON-SHIELDED,MID CAP FPL WIRE. (RISER OR PLENUM RATED WIRE WHERE party.TYP,ALL SHEETS PROJECT NOTES V /I REQUIRED PER NEC). 5. THE DETECTION COMMUNICATION LOOP DOES NOT REQUIRE AN ELR AT THE END OF THE CIRCUIT. •TECHNICIAN TO AS-BUILD DEVICE ADDRESSES •AMBIENT TEMPERATURE 70'F IN ALL SPACES 6. WIRE TO WEATHERPROOF DEVICES SHALL BE STUBBED OUT ONLY. AMBIENT SOUND LEVEL>40DB IN ALL SPACES SURFACE WEATHERPROOF BACK BOXES SHALL BE PROVIDED WITH DEVICES. LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE 7. ALL FIRE ALARM WIRES ARE REQUIRED TO BE IDENTIFIED AND Provide Buildin SOLE PROPERTY OF IN PAR WRITTEN g I WHOLE IONS, LN WITHOUT REPRODUCTION IO ON THE W - APPROPRIATELY MARKED. CODStrUCIIOn Typo /�I I r T 8. PER NEC, NO AC VOLTAGE WIRING OF ANY KIND SHALL BE RUN IN THE SEWUENGE OI OPERAI IONS PERMISSION OF ABSCO SOLUTIONS,INC. SAME CONDUIT OR RISER AS THE LOW VOLTAGE FIRE ALARM SYSTEM WIRING. IS PROHIBITED.PATENT RIGHTS(WHERE All panels shall be OTH ER AP ROPR ETARCOPYRIGHTS R RIGHTS ARE 9. ALL JACKETED CABLE MUST INCLUDE A JACKET REMOVAL PULL STRING interconnected by a fiber E X P R E S S L Y R E S E R V E D B Y AS PART OF THE CABLE. network. Fiber is shown on output Activated A B s c o SOLUTIONS, I N C. 10. SHIELDED CABLE IS NOT AN ACCEPTABLE SUBSTITUTION Fo the design drawings but is not General Transmit Transmit W R TH Nbtifioa5on-Minn Transmit Trouble Su specifically listed in the Provide Code pervisory Designer of Record E G E L: specifications 283100. References Horn+Horn Alarm Signals at Signals at ABSCO SOLUTIONS,INC. KEN DAY Alarm Device Strobe+Strobe Signals FACP FACP 19023 36TH SOLUTIONS, W STE E 1. ALL FIRE ALARM JUNCTION BOXES ARE TO BE PAINTED RED. Snake Detec ar X X LYNNWOOD,WA 98036 2. ALL END OF LINE DEVICES SHALL HAVE AN IDENTIFYING E.O.L. STICKER Manual Pull Station X X PHONE:(425)771-1166 EMAIL: AT THE E.O.L. LOCATION. FAX:(425)771-4422 FACP Alarm X X KEN.DAY®ABSCOSOLUTIONS.COM : 3. ONLY CONDUCTORS INTENDED FOR TERMINATION TO THE SPECIFIC FACP Trouble X NICET IV W 97083 ^ DEVICE ANY GIVEN JUNCTION BOX SHALL BE LEFT OPEN FOR Provide a"Scope of FACP Supervisory X TERMINATITI ON IN THAT JUNCTION BOX. ALL OTHER CONDUCTORS SHALL PASS Work" THROUGH,OR BE SPLICED THROUGH,THAT JUNCTION BOX. VaIVa Supervisory X Water Flow Alarm X X WARRANTY ALL EQUIPMENT AND LABOR PROVIDED BY ABSCO SOLUTIONS,INC. HAS A WARRANTY OF ONE YEAR FROM DATE OF INVOICE. THIS WARRANTY EXCLUDES ALL COVERAGE FOR CONSEQUENTIAL DAMAGES,AND IS GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES OR IMPLIED WARRANTIES OF F FITNESS, HABITABILITY,OR MERCHANTABILITY OTHERWISE PROVIDED UNDER THE LAWS OF WASHINGTON. ANY WARRANTY WORK PERFORMED BY ABSCO 1-09/29/22 Submittal Set AP SOLUTIONS, INC. DOES NOT EXTEND THE WARRANTY OF ONE YEAR FROM THE DATE OF THE INVOICE. Rev.#-Date Revision By THIS WARRANTY SHALL BE VOID IF A PERSON OR FIRM OTHER THAN ABSCO SOLUTIONS, INC.OR THE CONTRACTOR AUTHORIZED BY ABSCO SOLUTIONS, INC. PERFORMS OR RE-PERFORMS ANY WORK IDENTIFIED WITHIN THE ORIGINAL SCOPE OF THE WORK OF THE CONTRACT WITH ABSCO Drawn By A.P. SOLUTIONS, INC. LEGAL NOTICE:THE INFORMATION CONTAINED IN THIS DRAWING IS THE Checked By D.H. SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS, INC. IS PROHIBITED. PATENT RIGHTS(WHERE APPLICABLE)COPYRIGHTS AND Date 09/29/22 ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY ASSOC SOLUTIONS, INC. Project Name PWC NORTH COMM OFFICE VICINITY MAP Project Number 24339 G System Type v amA Kp FIRE „ p •o. A,.,, w.p _ ALARM r a Pc,­9 M.. sheet Nam V LEGENDS, V DETAILS, qa=A FIRE ALARM iWM�M A,o,o PLANS � m Sheet Number H o W,h a aAIo FZ 0 01 SHEET 1 OF 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address Absco Solutions P.O. BOX 2246 A LYNNWOOD, WA 98036 PH: 425.771.1166 FAX: 425.771.4422 -W.0 bscosolutions.com SLP-BLK FACP BATTERY CALCULATIONS NOTIFICATION CIRCUIT CALCULATIONS Project Name and Address PANEL TYPE-LOCATION SUP-BLK FACP-MAIN FLOOR 3 Absco BATTERY STANDBY REQUIREMENTS 2.0 mA max.each ckt.-6A Total SolutionsPANEL CIRCUIT INFOF2MATIIXJ JOB NAME:24339-PWC North County Community Office PUD 1-FA 4 ckCS available Total Amp= 0.46 INlarunoN THAT EMRTNHSAID PRJlECTS NOTIFICATION CRCUIT# N1 N2 N3 N4 LI � Standby Alarm standby Alarm TOTAL it OF DEVICES 3 1902:1361,A-W.Suihe E,Ly-waad,WA 96036 Current Current CwRM CMRMt Rime:(425)T71-1166 Fmc(425)]71-4422 A, Arras Arras An" CURRENT DRAW 0.459 CD Ill OTY III s D..cdpd. TyPs Each Fiam Tar Taw CIRCUIT SPARE CAPACITY 77% 100% 100% 100% LJJ N B 2 AM,2F Addressable N msor M cdule IN O.00D7 0.0 006 0.0008 0OD12 WIRE GAUGE 14aV8I - - o t ASO-PL3-IV Analog DIalog phdoakolu-sensor, IN 0.0002 0.00/.5 0.0002 DOOM VOLTAGE DROP% 1.5% - t DIAlsrm Camarcdon PAN 0.018 0.018 0.015 0.0180 VOLTAGE DROP 05% - - - � M t FM4© a p module Rt loodule-WN node S(P 0.053 0.053 0.053 0.0530 W t Ms7AF Admmsmele amre atom pa sbllm IN 0.0003 aam 0.060 aoo70 ETD OF LINE VOLTAGE 23.84 1 P2wK 75cd WP WallMR Nun sane,12/24 BIG 0.000 0.176 OODO 0.1760 MAXIMUM WIRE LENGTH(FEET) 125 - - LJ �J l t P21ML 75cd wall alMoutkrn Snag.wh SIG 0.000 0.162 0.000 0,12t0 O 1 P2WL 1t0ulWal Maotltrn SMhe.WhNe SIG 0.000 0.182 0.000 0.1820 t I1PT--E3-UIP Ward Repealer,Ushirdad PAN 0.013 0.OU1 0.013 0.0730 t SLC-PM 9lP add on SLC nodule PAN 0.014 0.014 0.014 0.0140 t SLP-BILK SmartbapprM PAN 0.111 0,243 0.111 0.2430 O CO rn V I C O � Ln0 � 0 :5i Ooz 12 Talel UTotd. M=. O NOTES: SLP-1LK1" 24v]ah Emery Capacity O TaNh Sbnmmy Carret 0,210 Tod Shrr*y: 5.0472 x standby hours nerd: 24 +Tar Ad- 0.067 / � / O D TOMI: .0 TCW 5.115 f TOMIam AI Curert 0.813 X parading factor: 1.2 �l X fracdon of hours reds°:0.083 Tar An,Hburs Needed: 6.138 TONI: 0.067 Salary ,rmrnnt 7eh LEGAL NOTICE: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ABSCO SOLUTIONS, INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION OF ABSCO SOLUTIONS,INC. IS PROHIBITED.PATENT RIGHTS(WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY A B S C 0 SOLUTIONS, INC. Designer of Record F KEN DAY ABSCO SOLUTIONS,INC. 19023 36TH AVE W STE E LYNNWOOD,WA 98036 PHONE:(425)771-1166 F.:(425)7J1-4422 EMAIL:KEN.DAY®ABSCOSOLmONS.COM NICET:IV W 97083 FIRE ALARM RISER ----------------------------------------------------------------- MAIN FLOOR MAIN FLOOR F 1-09/29/22 Submittal Set AP 1`11-3 B B N1-1 B A A A A ELR. 0.459MA r - # Rev.-Date Revision By 1 tOcd 75cd 75cd Lt M20 MWI Lt M301 E011 All panels shall be interconnected by a fiber WP network as shown on design drawings. Drawn By A.P. Where term"by others"is used,confirm the Cellular y Checked By o.H. � responsible party and verify that party will communicator provide the service or installation as Date 09/29/22 referenced. Revise the term"by others"to FADC FACP C MCP specify the responsible party.TYR,ALL Project Name `WC NORTH COMM OFFICE SHEETS Project Number 24339 TO NETWORK(BY OTHERS) G TO PHONE LINE(BY OTHERS) system Type TO 120VAC(BY OTHERS) FIRE MAIN FLOOR MAIN FLOOR ALARM Sheet Name NOTIFICATION CIRCUIT & BATTERY CALCULATIONS, FIRE ALARM RISER Sheet Number H 7 FZ002 SHEET 2 OF 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Firm Name and Address Absco Solutions P.O. BOX 2246 A LYNNWOOD, WA 98036 PH: 425.771.1166 FAX: 425.771.4422 —W.,bscosolutions.com Project Name and Address \ O l B / Z N 00 Z LEI M _ Adjust the 0 Q background Color/line O weight so the floor plans are visible. I_ n � I = � 0 C 4"CONGh Ln MECH UNIT. MECH DRAV\ TO PHONE LINE(BY OTHERS) O O z TO 120V (BY OTHERS) O _ TO NETWORK (BY OTHERS) 4R . BN1-1 102 IA p 75cd W • WP L1 75cd r n O A u A4 Verify sprinkler riser /� L1 M31 location.Locate the sprinkler monitoring devices at the LEGAL N sprinkler riser CONTAINED TIN ETH ISH DRAWING�S TION THE Ire arm Contractor location. SOLE PROPERTY OF ABSCO SOLUTIONS, to confirm location INC.ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT THE WRITTEN with Arlington Fire PERMISSION OF ABSCO SOLUTIONS,INC. and District "'-�., IS PROHIBITED.PATENT RIGHTS(WHERE APPLICABLE) COPYRIGHTS AND ALL OTHER PROPRIETARY RIGHTS ARE EXPRESSLY RESERVED BY Verify dedicated ABSCO SOLUTIONS, INC. exterior sprinkler bell Designer of Record F KEN DAY ABSCO SOLUTIONS,INC. 19023 36TH AVE W STE E LYNNWOOD,WA 98036 N1-3 PHONE:(425)771-1166 ELR. 0. 9mA FAx:(425)771-4422 EMAIL:KEN.DAY®ABSCOSOU-TmNS.COM B 110cd NICE/T:IV#97083 t F 1-09/29/22 Submittal Set AP Rev.#—Date Revision By Drawn By A.P. MAIN FLOOR-FIRE ALARM PLAN a Checked By D.H. SCALE: 1/8—V ID" Date 09/29/22 Project Name PWC NORTH COMM OFFICE Project Number 24339 System Type a ® FIRE I I ALARM Sheet Name I MAIN FLOOR FIRE ALARM PLAN Sheet Number Ii KEYPLAN TAN C O SCALE: NTS SHEET 3 OF 3 1 2 3 4 5 6 7 8 M o �Z Z 8 6 bM ` N O10 N M�b P1; = sum= 8 g N /fib H 16 0 9 L op -:1g�2�y E _ N �; ° o x- u�wo a Y ; '' � n' W E J E 0 0 ,/�/l JI I///�\\ ///�\\ /I\ (\ III o' a Y" J �~ m;a N m V J 0 x Y 1 1 1 0 / \�N n 0 H.l V 0 N _ w ; ao_wF v bFgN2 - e d Q a E Q W w Q = N ; 6 tiQ �fi1 g e5'• w �1 4 O z a a z : � �w € e J€ •A a z= o /� ��n\\ /-�/t N //^\\ N ^\\ `^\ z g s m a x `I M� �• - E5 - ° (1j ; LL and / \ V 0 V Y 0 O V �J Uzm� H <owa z 8 ae uj w W LL m) LL n m m F ?U � I J J w r 'a c J (i iJ c a � _ a. z z g 3� 25 B a Oi lai- x x d. 'J @ O Is38;> f-`FQ xJ !j jig A 5 =x x x x LL AR Of W W z ��_ s W _< j y5� x J z z z b LO Of U tll - W cvi� o�� $c I-A"•I55 � WI Z LLJ gig i9 � WW �N � Z zap Y ��m LLL�IYY���� o O t ! 4 T LL O z 6z UgwJ6 ll�bbddr ,U s` y a 0 g U W x z z L� ME a-J oE2 ,.I O I I 0•M ! i 08 I o J y � W p M z 1 1 �w O J`<G n W CO a 3s N N N 5 Y °y w a wWa aw W� �V d2 .C. JfWjZ222O= 22 z �� - � i N o ma >OJ ��n`� C o Y� � �' L^-6 . 31 °rL0 t- -N W OC fG� K �I� Ka O 5 mO0 3 �Zw °mC CFNO O "11 W 'E3 oLLe N o 3 5 �s z o f z�- za s Y pUpUo &a ,es s me F m z oo-Z$ $ I;j3w � al. 0 0�0 0�" oa 3 ° pia o ow a rimFw zvi zz �^ w wmi o m o ow m F a z ro `� oo ~ �a ..� Uwm o °Y O o a y� -w z a zg m °z x Sso m ;r Z o $- kFc� o o P >o om J z 4 C i s c o� ° aYk z w z '� o mo u wz a oa N m No m w� Y 7 m zaY d C1 F u g 3p,a 8 ao aim s o wm� 8?`<w' Yx xm � x� iz i oa a°� ino S �m w� o mQ' ?- Ym£�oo xd a�sw Z u�°d L'Jz °a ei z i �gw m g z zww z� N o x aw a yi > m F— �W ° I—' U aawN mw a ��� a W& w z0gga rc 3 0� m m m o� x N� Q o o3w ¢w Wo w Y des z �W8 $�o ss z� z = °o « o w mSiEE 3� ooa° ooav o (/I fa z Fw p o xa °z s �i° o �3 uw z o°mmu CL' z w H L _d 5<<<� €a�� €� €��o �a Hw� z w �w ow O Ux � z $ � oxx � a o aWz �o�a zo r c Gm J 3w � 3 3 na& 3� 3m $ =w �i a� a �m 3i ado � m zz o Q so�3�r o cga �� o z o>-n Y '� Y Y ' z H ozs 'a 0 m 2-o.�� V az Fg$N "' m �x a UPI S� z � c ox �m ��ow oa3'Y _ a o ° `' m z rc rr,,,€zd�y m P-- w w a o " �ut� o`"s. mN ° � ��" X� ��o �� 5i.iw� �° zsw �� i� zw sF � z� � � z�U i�w � ?pwz� � o�w N s �iG U z o z 6 �' > z� k+zm H sd s_ P z o a m z o z° o LL moi52 °zLL M�k' P W u BYO k �W off° gY °ds� �v ao m� o� oo O �w >� y� o �� zd °i� uoo €��a ws r ///J Z z�cc -�icm3 id jw �° dE 3ii ��o� �F 3E y 53 � U °� w& zY �z �w z zF ozr-a w Nz�w r K� W av°z � �� `� z�w o �g �jy ���z oa ° \ s ziw z� z zo Jo � w io 52's �zwo �o a \\v w pp ° ° m -I z '3 0_ o a oz o m Un yW&a z m cwi 7aoaoo i4 zv o� ok ci . �i zo a Ni= ooz wo3g zzO o a zc pZO� LL -t WN xd°NN�z 3xm&N O rcwg �rz�`o 'n o$w o gza>w �� _ wa °m qx °� o Ug ZQ Z YUU a �� C, ��3 �'gLL-Na w�ri'm w°IV Wy1�6 x� Zyf N6� G WN� WZON �� U� w Jw N� Z N �Z H"; ie:n, ... - ....., ...... a ��55 W 'Y W O E, � bwo Naww g m oUo �W 6zm vir- �m rm m° a 3 ° NaWWm ...,,.... � N� gm i I`9 �cxi z x3°NN F�w� 3a �m5'a^ �mz o °a� �vxirc �w �a a" N O�-`4'�zo � ,�c B ? u z cq�,+ rcFra m_�<I �d € x & 7, a 5 �a �a c'�' oho w55�� �oFow mzx O .moo z �+ �� ciS� ri�n a In °c>¢ mood' I�or3i� aa3 °ism m .o a o°w x o da t7i °i� r��& 3Uw�ww= o oc -I a ��wm �i t-h° M�rz 6a o aw�W r9i�h you a m o w x M o �=96 bM N=Nl� ]VLLJ N ! a f0 07 dN•ai zTi3 '�ui= `�i^°ry N Z Z N M B V N 3 ^ g IN ]Ad N169 � 09 Z- o o o g �iU9oo°O /�aN� i13AAO OVVYVOV L OO iKN �z ��a`o?o ` by ;µ' �S a o m a 8L�UQ�g N a �W.,�� 7i1 � � 4 a a ; g ao ` mg $z I A j 2 U m Q W J ; and ),.,J_Nno3 Hs AoNoNs U , o � o z I IJ JI ~ IZ ZI I g I gC:s 14 I o I Z> YNY �N sr dcddad 'e I L------ r m V50503a § e � del LLJ m Q j =o ,ae I I w N qqqq �� Jw J Z Z a N Q I m I V O W W l7 2 2 Z z 9 6 bM ` NOiSWI IV w 8 � :a Napo IN ]AV H165 � 09� 0 E 3030 =V� a � N E. mow ° v o w w m o n o E a o o N E Q J �- M r a J =�aa=xm - w EQ a �} and XiNn03 HS AOHONS ¢ w rn� CL tYi_Q t. L I Q ( r r r 4 r r � � r r � I r r 1 r z r r I I r I 1 I I I •ate-, u o rL iT Ex Z Z I o 3F I i � <I m ti J LU I J I z r I Q o ——————— ———— w�n I 3 z w� '1 o- -, o w • J I � Q al m N oa "a J o> m� y m wr m O p O O T GFi o Z m Q Permit#: 5628 Permit Date: 10/06/23 Permit Type: FIRE ALARM Project Name: 24339-PWC North County Community Office PUD 1 - FA(Parking Garage) Applicant Name: Melinda Noordman/Absco Applicant Address: 3400 188th St SW Applicant, City, State, Zip: lynnwood Contact: Melinda Noordman Phone: 4257711166 Email: Melinda.Noordman@abscosolutions.com Scope of Work: Provide fire alarm life safety Valuation: 4140.75 Square Feet: 2184 Number of Stories: 1 Construction Type: 1113 Occupancy Group: S-1; Storage Mod Hazard ID Code: CIC Permit Issued: 11/28/2023 Permit Expires: 05/27/2024 Form Permit Type: FIRE ALARM Status: EXPIRED Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning Section 22 Township 31 Range 5 Quarter SE LOT 2 CITY ARL BSP FILE NO PUBLIC UTILITY 489 Other Utilities 31052200405500 17601 59TH AVE NE SPUD00000142 REC AFN DISTRICT NO 1 NEC 202105145008 BEING A PTN NW1/4 SE1/4&NE1/4 SE1/4 SD SEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# ABSCO Solutions Inc Julie Aspnes 19023 36th Ave CONSTRUCTION UBI 600 260 973 STE E CONTRACTOR ABSCO Solutions Inc Julie Aspnes 19023 36thAve CONSTRUCTION Contractor ABSCOA1961J3 STE E CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 11/07/2023 FIRE ALARM BUILDING Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-2 $95.92 FACP/Transmitter-New $200.00 Fire Alarm System Permit NFPA 72- 105.7.3 $350.00 Credit Card Service $20.13 Total $691.05 Attached Letters Date Letter Description 11/28/2023 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/23/2023 XBP Con£ $670.92 156870317 10/23/2023 156870317 Ameresia Lawlis $20.13 Outstanding Balance $0.00 Notes Date Note Created By: 04/26/2024 sent expiration notice Hannah Hardwick 03/25/2024 sent expiration notice Hannah Hardwick 11/28/2023 sent permit for signature Hannah Hardwick 10/06/2023 Need to add COA license Hannah Hardwick Need to update the valuation and devices.This was 1 permit for 3 buildings.Changed to 3 10/06/2023 separate permits.waiting on applicant to provide itemized valuation per building. Hannah Hardwick Uploaded Files Date File Name 11/28/2023 17607807-2023 BLD5628 IssuedPermit.pdf 11/28/2023 17607773-2023 BLD5628 ForSignature.pdf 11/27/2023 17593847-20231127 BLD Approved Plans.pdf 10/06/2023 17115912-20231006 BLD5628 Specs.pdf 10/06/2023 17115913-20231006 BLD5628 App.pdf 10/06/2023 17115914-20231006 BLD5628 Parking Garage Plans.pdf