HomeMy WebLinkAbout18520 67th Ave Ne_BLD5648_2026 Burns Fire Protection Systems, Inc. P.O. Box 1110 Granite Falls, WA 98252 PH: (425) 388-0124 Seattle Galvanizing Co 18520 67th Ave NE Arlington, WA 98223 Item No DESCRIPTION MANUFACTURER MFG. NO. FINISH REMARKS Air Compressor General Air Maintenance Device Tyco Wall Mount FDC FPPI 4 x 2.5 x 2.5 Hose Valve FPPI Backflow Preventor Ames Derringer 30 Check Valve Tyco CV-1 Blue/BLK Electric Bell Potter Red Dry Valve Tyco DPV-1 Sprinkler Head Tyco TY3131 WH Sprinkler Head Tyco TY3151 Chr Sprinkler Head Tyco TY3351 WH Sprinkler Head Tyco TY3331 WH Storage Cabinet FPPI Red Steel Pipe Bull Moose Eddy Flow Steel Pipe Bull Moose Sched 10/40 Blk Sammy Screw All Buildex Hangers Caddy Seismic Bracing Caddy Sway Brace Caddy Grooved Coupling Victaulic 009H Orange Grooved Fitting Victaulic Orange Mech Tee Tyco 730 Orange Threaded Fittings Shurjoint Blk tqC0 Fire & Building Products Technical Services: Tel: (800) 381-9312/Fax: (800) 791-5500 Series TY-B — 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General standard corrosion tests of the appli- cable approval agencies,the testing is Description not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be The Series TY-B, 5.6 and 8.0 K-factor consulted with respect to the suitability Upright and Pendent Intermediate of these coatings for any given corro- Level Sprinklers described in this data sive environment.The effects of ambi- sheet are automatic sprinklers of the ent temperature, concentration of "standard response" 5 mm frangible chemicals, and gas/chemical velocity, bulb type. They are "standard spray" should be considered, as a minimum, -_ - sprinklers intended for use in fire sprin- along with the corrosive nature of the kler systems designed in accordance chemical to which the sprinklers will be with the standard installation rules rec- exposed. ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright Sprinklers WARNINGS it produce a hemispherical water distri- The Series TY-B Sprinklers described bution pattern below the deflector. herein must be installed and main- tained in compliance with this docu- Intermediate Level Sprinklers are pri- ment, as well as with the applicable marily designed for use in rack storage standards of the National Fire Protec- sprinkler systems where their ther- tion Association, in addition to the mally sensitive elements must be standards of any other authorities hav- shielded from the water spray of higher ing jurisdiction. Failure to do so may elevation sprinklers that could operate impair the performance of these de- r _ earlier during afire.Intermediate Level vices. Sprinklers are also used in other appli- cations such as beneath open gridded The owner is responsible for maintain- catwalks. ing their fire protection system and de- vices in proper operating condition. Corrosion resistant coatings, where The installing contractor or sprinkler Technical applicable, are utilized to extend the manufacturer should be contacted life of copper alloy sprinklers beyond with any questions. Data that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- Approvals tant coated sprinklers have passed the 11llodel/Sprinkler UL and C-UL Listed. FM and NYC Approved. Identification (Refer to Table A for complete approval information including corrosion resis- IMPORTANT tant status.) Y Always refer to Technical Data umbers Sheet TFP700 for the "INSTALLER Maximum Working Pressure WARNING" that provides cautions TY3153- Upright 5.6K, 1/2"NPT 175 psi (12,1 bar) with respect to handling and instal- TY3251 - Pendent 5.6K, 1/2"NPT Discharge Coefficient TY4153- Upright 8.OK,3/4"NPT g a lation of sprinkler systems and com TY4251 - Pendent 8.OK,3/4"NPT K=5.6 GPM/psis/2 (80,6 LPM/bars/2) 0 ponents. Improper handling and in- K=8.0 GPM/psil/2(115,2 LPM/bars/2) 2 stallation can permanently damage a sprinkler system or its compo- Temperature Ratings nents and cause the sprinkler to fail Refer to Table A o to operate in a fire situation or cause Finishes a it to operate prematurely. Sprinkler: Refer to Table A o Page 1 of 6 JANUARY, 2005 TFP351 Page 2 of 6 TFP351 7/16" (11,1 mm) 1/2"** 3-1/2" (88,9 mm) DIA, NOMINAL MAKE-IN NPT SHIELD O-RING SCREW lik/ UPRIGHT 7/16" 2 3/16" SHIELD* (11,1 mm) 2-3/8" (55,6 mm) MODEL S2 WRENCHING NOMINAL (60,3 mm) SHIELD FLATS MAKE-IN WRENCHING 1 FLATS 1 3-1/2" (88,9 mm) DIA, 1/2"** NPT PENDENT UPRIGHT (FIELD ASSEMBLED-SEE INSTALLATION SECTION) (FACTORY ASSEMBLED) * Temperature rating is indicated on the deflector, shield, or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY3153)AND PENDENT(TY3251)SPRINKLERS INTERMEDIATE LEVEL SPRINKLERS, 5.6 K-FACTOR, 112 INCH NPT 1/2" (12,7 mm) 3/4"** 3-1/2" (88,9 mm) DIA, NOMINAL MAKE-IN NPT SHIELD O-RING SCREW 2 5/16" UPRIGHT 1/2" (58,7 mm) MODEL S2 WRENCHING SHIELD* (12,7 mm) 2-7/16" NOMINAL (61,9 mm) SHIELD FLATS MAKE-IN WRENCHING 1 FLATS 1 3-1/2" (88,9 mm) DIA, 3/4"** PENDENT NPT UPRIGHT (FIELD ASSEMBLED-SEE INSTALLATION SECTION) (FACTORY ASSEMBLED) * Temperature rating is indicated on the deflector,shield,or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY4153)AND PENDENT(TY4251)SPRINKLERS INTERMEDIATE LEVEL SPRINKLERS, 8.0 K-FACTOR, 314 INCH NPT TFP351 Page 3 of 6 SPRINKLER FINISH(See Note 5) K TYPE TEMP. BULB NATURAL LEAD WAX WAX OVER LIQUID BRASS*** COATED COATED LEAD COATED 135°F/57°C Orange UPRIGHT 155°F/68°C Red 5.6 (TY3153) 1,2,3,4 1,2,3,4 1,2,3,4 1,2,3,4 1/2" 175°F/79°C Yellow NPT 200°F/93°C Green 286°F/141°C Blue 1**,2",3**,4" 1",2**,3",4" 360°F/182°C Mauve N/A 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3251) 1,2.3,4 N/A 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve 135°F/57°C Orange UPRIGHT 155°F/68°C Red 80 (TY4153) 1,2.3,4 1,2.3,4 1,2.3,4 1,2,3,4 3/4" 175°F/79°C Yellow NPT 200°F/93°C Green 286°F/141°C Blue 1",2",3",4" 1",2",3",4" 360°F/182°C Mauve N/A 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4251) 1,2,3,4 N/A 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve NOTES: 1.Listed by Underwriters Laboratories, Inc.(UL). 2.Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL). 3.Approved by Factory Mutual Research Corporation(FM). 4.Approved by the City of New York under MEA 354-01-E. 5.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. " 150°F/66°C Maximum Ceiling Temperature. With Zinc Plated Shield. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS Page 4 of 6 TFP351 Physical Characteristics —Upright Sprinklers— Frame . . . . . . . . . . . . . Bronze The Series TY-B Intermediate Level Button . . . . . . . . . Brass/Copper Upright Sprinklers must be installed in Sealing Assembly . . . . . . . . accordance with the following instruc- / WRENCH RECESS Beryllium Nickel w/Teflont tions. (END"A"USED FOR Bulb . . . . . . . . . . . . . . . Glass Step 1. With pipe thread sealant ap- plied 1/2"NPT MODELS) Compression Screw Bronze plied to the pipe threads, hand tighten Deflector . . . . . . . . . . . Copper the sprinkler into the sprinkler fitting. Shield . . . . . . . . . . Plated Steel Step 2. Tighten the sprinkler into the WRENCH RECESS sprinkler fitting using only the W-Type (END"B"USED FOR 6 Sprinkler Wrench (Ref. Figure 3), 3/4"NPT MODELS) Operation except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax FIGURE 3 The glass Bulb contains a fluid which coated sprinklers. With reference to W-TYPE 6 SPRINKLER expands when exposed to heat.When Figure 1 or 2, the W-Type 6 Sprinkler WRENCH the rated temperature is reached, the Wrench or the Crescent wrench, as fluid expands sufficiently to shatter the applicable, is to be applied to the glass Bulb, allowing the sprinkler to wrench flats. activate and water to flow. ing the wrench. — Pendent Sprinklers—The Series TY-B Intermediate Level After installation, the sprinkler wrench flats and frame arms must be in- Design Pendent Sprinklers must be installed spected and the wax coating re- in accordance with the following in touched(repaired)whenever the coat- Criteria structions. ing has been damaged and bare metal Step 1.Thread the S2 Shield onto the is exposed. The wax coating on the The Series TY-B Pendent and Upright sprinkler threads with the stamped wrench flats can be retouched by gen- Intermediate Level Sprinklers are in- markings toward the deflector and just tly applying a heated 1/8 inch diameter tended for fire protection systems de- to the end of the threads. The final steel rod to the areas of wax that have signed in accordance with the stand- assembly step is easier to accomplish been damaged,to smooth it back over and installation rules recognized by the if the Shield is not disengaged by con- areas where bare metal is exposed. applicable Listing or Approval agency tinuing to turn the Shield past the (e.g., UL Listing is based on the re- threads. NOTES quirements of NFPA 13, and FM Ap Step 2. Roll the O-Ring over the sprin Only retouching of the wax coating ap- proval is based on the requirements of er threads until it seats against the plied to the wrench flats and frame FM's Loss Prevention Data Sheets). Shield. arms is permitted, and the retouching is to be performed only at the time of Step 3. With pipe thread sealant ap- the initial sprinkler installation. Installation plied to the pipe threads, hand tighten The steel rod should be heated only to the sprinkler into the sprinkler fitting. the point at which it can begin to melt The Series TY-B Sprinklers must be Step 4. Tighten the sprinkler into the the wax, and appropriate precautions installed in accordance with the follow- sprinkler fitting using only the W-Type need to be taken, when handling the ing instructions: 6 Sprinkler Wrench (Ref. Figure 3). heated rod, in order to prevent the With reference to Figure 1 or 2, the installer from being burned. NOTES W-Type 6 Sprinkler Wrench is to be If attempts to retouch the wax coating Do not install any bulb type sprinkler if applied to the wrench flats. with complete coverage are unsuc- the bulb is cracked or there is a loss of Step 5.Rotate the S2 Shield clockwise cessful,additional wax can be ordered liquid from the bulb. With the sprinkler (looking up) so that it slightly com- in the form of a wax stick (the end of held horizontally, a small air bubble presses the O-Ring between the which is color coded).Only the correct should be present. The diameter of the Shield and sprinkler fitting. color coded wax is to be used, and air bubble is approximately 1116 inch retouching of wrench flats and frame (1,6 mm) for the 135°F/57°C to 3132 arms is only permitted at the time of inch (2,4 mm) for the 360°F/182°C —Wax Coated Sprinklers— initial sprinkler installation. With the temperature ratings. When installing wax coated sprinklers steel rod heated as previously de- A leak tight 112 inch NPT sprinkler joint with the adjustable Crescent wrench, scribed, touch the rod to the area re- should be obtained with a torque of 7 additional care needs to be exercised quiring additional wax with the rod an- to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- to prevent damage to the wax coating gled downward, and then touch the mum of 21 ft. lbs. (28,5 Nm)of torque on the sprinkler wrench flats or frame wax stick to the rod approximately one- may be used to install sprinklers with arms and, consequently, exposure of half inch away from the area requiring 112 NPT connections. A leak tight 314 bare metal to the corrosive environ- retouching. The wax will melt and run inch NPT sprinkler joint should be ob- ment. The jaws of the wrench should down onto the sprinkler. tained with a torque of 10 to 20 ft.lbs. be opened sufficiently wide to pass (13,4 to 26,8 Nm). A maximum of 30 over the wrench flats without damag- ft.lbs. (40,7 Nm)of torque is to be used ing the wax coating. Before wrench to install sprinklers with 314 NPT con- tightening the sprinkler,the jaws of the nections. Higher levels of torque may wrench are to be adjusted to just con- distort the sprinkler inlet and cause tact the sprinkler wrenching flanges. leakage or impairment of the sprinkler. After wrench tightening the sprinkler, loosen the wrench jaws before remov- TFP351 Page 5 of 6 Care and It r recommended that automatic Ordering sprinkler systems be inspected, tested, and maintained by a qualified procedure Maintenance Inspection Service in accordance with local requirements and/or national The Series TY-B Sprinklers must be code. When placing an order,indicate the full maintained and serviced in accord- product name. Refer to the Price List ance with the following instructions: for complete listing of Part Numbers. Limited y NOTES Contact your local distributor for avail- Before closing a fire protection system Warrant ability. main control valve for maintenance Upright Sprinkler Assemblies with work on the fire protection system that Products manufactured by Tyco Fire Shield and NPT Thread itcontrols,permission to shutdown the Products are warranted solely to the affected fire protection system must be original Buyer for ten (10) years Connections: obtained from the proper authorities against defects in material and work- Specify: (Specify Model/SIN), Stand- and all personnel who maybe affected manship when paid for and properly and Response, (specify K-factor), by this action must be notified. installed and maintained under normal (specify temperature rating), Series use and service.This warranty will ex- TY-B Upright Intermediate Level Sprin- Sprinklers that are found to be leaking pire ten (10) years from date of ship- kler with (specify type of finish or coat- or exhibiting visible signs of corrosion ment by Tyco Fire Products. No war- ing), P/N (specify from Table B). must be replaced. ranty is given for products or Automatic sprinklers must never be components manufactured by compa- Pendent Sprinkler Assemblies with (Shield Ordered Separately)and painted, plated, coated or otherwise nies not affiliated by ownership with altered after leaving the factory. Modi- Tyco Fire Products or for products and NPT Thread Connections: Specify: (Specify Model/SIN), Stand fied sprinklers must be replaced. components which have been subject Sprinklers that have been exposed to to misuse, improper installation,corro- and Response, (specify K factor), corrosive products of combustion, but sion, or which have not been installed, (specify temperature rating), Series have not operated,should be replaced maintained,modified or repaired in ac- TY-B Pendent Sprinkler with (specify if they cannot be completely cleaned cordance with applicable Standards of type of finish or coating), P/N (specify by wiping the sprinkler with a cloth or the National Fire Protection Associa- from Table C) by brushing it with a soft bristle brush. tion, and/or the standards of any other Model S2 Pendent Shield &O-Ring: Care must be exercised to avoid dam- Authorities Having Jurisdiction. Mate- Specify: S2 Pendent Shield & O-Ring age to the sprinklers - before, during, rials found by Tyco Fire Products to be for use with (specify 1/2" NPT or 3/4" and after installation. Sprinklers dam- defective shall be either repaired orreplaced, at Tyco Fire Products' sole NPT) Series TY-B Pendent Sprinklers, aged by dropping, striking, wrench option. Tyco Fire Products neither as P/N (specify). twist/slippage, or the like, must be re- sumes, nor authorizes any person to placed.Also, replace any sprinkler that assume for it, an other obligation ation in 1/2" NPT S2 has a cracked bulb or that has lost y g Pendent Shield liquid from its bulb. (Ref. Installation connection with the sale of products or &O-Ring .............. P/N 56-070-9-332 Section). parts of products. Tyco Fire Products 3/4 NPT S?Shield shall not be responsible for sprinkler Frequent visual inspections are rec- system design errors or inaccurate or &O-Ring .............. P/N 56-070-9-342 ommended to be initially performed for incomplete information supplied by Sprinkler Wrench: corrosion resistant coated sprinklers, Buyer or Buyer's representatives. Specify: W-Type 6 Sprinkler Wrench, after the installation has been com- IN NO EVENT SHALL TYCO FIRE P/N 56-000-6-387. pleted,to verify the integrity of the cor- PRODUCTS BE LIABLE, IN CON- rosion resistant coating. Thereafter, TRACT,TORT,STRICT LIABILITY OR Wax Sticks: annual inspections per NFPA 25 UNDER ANY OTHER LEGAL THE- (for retouching wrench damaged should suffice; however, instead of in- ORY, FOR INCIDENTAL, INDIRECT, wax coating) specting from the floor level,a random SPECIAL OR CONSEQUENTIAL Specify: (Specify color) color coded sampling of close-up visual inspec- DAMAGES, INCLUDING BUT NOT Wax Stick for retouching (specify tem- tions should be made, so as to better LIMITED TO LABOR CHARGES, RE- perature rating)temperature rated Se- determine the exact sprinkler condi- GARDLESS OF WHETHER TYCO ries TY-B Sprinklers, P/N (specify). tion and the long term integrity of the FIRE PRODUCTS WAS INFORMED corrosion resistant coating, as it may ABOUT THE POSSIBILITY OF SUCH Black for 135°F............ P/N 56-065-1-135 be affected by the corrosive conditions DAMAGES, AND IN NO EVENT Red for 1 ............. P/N 56-065-1-155 present. Yellow forr 17575°F. . . . .. . . . P/N 56-065-1-175 SHALL TYCO FIRE PRODUCTS' Lk Blue for 200°F and The owner is responsible for the in- ABILITY EXCEED AN AMOUNT 286°F................. P/N56-065-1-286 EQUAL TO THE SALES PRICE spection, testing, and maintenance of . their fire protection system and de- THE FOREGOING WARRANTY IS NOTES Each wax stick is suitable for retouch- vices in compliance with this docu- MADE IN LIEU OF ANY AND ALL ment, as well as with the applicable OTHER WARRANTIES EXPRESS OR ing up to twenty-five sprinklers. standards of the National Fire Protec- IMPLIED,INCLUDING WARRANTIES The wax used for 286°F sprinklers is tion Association (e.g., NFPA 25), in OF MERCHANTABILITY AND FIT- the same as for 200°Fsprinklers, and, addition to the standards of any other NESS FOR A PARTICULAR PUR- therefore,the 286°Fsprinkler is limited authorities having jurisdiction. The in- POSE. to the same maximum ceiling tempera- stalling contractor or sprinkler manu- ture as the 200oF sprinkler (i.e., facturer should be contacted relative to 150°F). any questions. Page 6 of 6 TFP351 P/N 57 - XXX - X - XXX TEMPERATURE TI SPRINKLER RANG MODEUSIN 135 135°F/57°C 533 5.6K UPRIGHT(1/2"NPT) TY3153 1 NATURAL BRASS 155 155°F/68°C 543 8.OK UPRIGHT(3/4"NPT) TY4153 7 LEAD COATED 175 175°F/79°C 6 WAX COATED 200 200°F/93°C 286°F/141°C MAX. 286 286°F/141°C 8 WAX OVER LEAD 286°F/141°C MAX. 360 360°F/182"C TABLE B PART NUMBER SELECTION SERIES TY-B UPRIGHT INTERMEDIATE LEVEL SPRINKLERS (UPRIGHT SHIELD INCLUDED WITH SPRINKLER) P/N 57 - XXX - X - XXX TEMPERATURE TI SPRINKLER RANG MODEUSIN 135 135°F/57°C 571 5.6K PENDENT(1/2"NPT) TY3251 1 NATURAL BRASS 155 155°F/68°C 591 8.OK PENDENT(3/4"NPT) TY4251 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C 360 360°F/182°C TABLE C PART NUMBER SELECTION SERIES TY-B PENDENT SPRINKLERS (MODEL S2 PENDENT SHIELD& O-RING MUST BE SEPARATELY ORDERED) TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale, Pennsylvania 19446 tqCaRre Suppression & Building Products Technical Services 800-381-9312 1+1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Corrosion-resistant coatings, where applicable, are utilized to extend the Description life of copper alloy sprinklers beyond that which would otherwise be obtained i d corrosive atmo- hen expose to corros The TYCO Series TY-FRB,2.8,4.2,5.6, w and 8.0 K-factor, Upright and Pendent spheres.Although corrosion-resistant Sprinklers described in this data sheet coated sprinklers have passed the j are quick response,standard coverage, standard corrosion tests of the appli- N decorative 3 mm glass bulb-type spray cable approval agencies,the testing is sprinklers designed for use in light or not representative of all possible cor- ordinary hazard,commercial occupan- rosive atmospheres. Consequently, cies such as banks, hotels, and shop- it is recommended that the end user ping malls. be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment. The effects of FRB Pendent Sprinkler,where applica- ambient temperature, concentration of ble, is intended for use in areas with a chemicals, and gas/chemical velocity, finished ceiling.This recessed pendent should be considered, as a minimum, sprinkler uses one of the following, along with the corrosive nature of the • A two-piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be i or Style 40 (3/4 inch NPT) Recessed exposed. Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- a l recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed —_ (19,1 mm)of total adjustment from the in Technical Data Sheet TFP356, and flush ,or a pendent position,P P Sprinkler Guards are detailed in Tech- • A two-piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch(6,4 mm)of recessed adjustment or up to 1/2 inch The Series TY-FRB Concealed Pendent Model/Sprinkler (12,7 mm)of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- Number (SIN) Recessed Escutcheon reduces the cable standards of the National Fire accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2-NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2-NPT the performance of these devices. TY2131: Upright 4.2K, 1/2-NPT Owners are responsible for maintaining TY2231: Pendent 4.2K, 1/2-NPT their fire protection system and devices TY3131: Upright 5.6K, 1/2-NPT in proper operating condition. The TY3231: Pendent 5.6K, 1/2-NPT IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.OK, 3/4-NPT Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.OK, 3/4-NPT Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.OK, 1/2-NPT WARNING" that provides cautions TY4931: Pendent* 8.OK, 1/2-NPT with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* \ 5 7/16° 2-1/4" q (11,1 mm) NOMINAL (57,2 mm) 2 MAKE-IN 3 2-3/16" 1-9/16" (55,6 mm) WRENCH (39,7 mm) 1 FLATS 7 1/2" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5W2-3/16" 7/16" (11,1 mm) 2-3/16" 4NOMINAL (55,6 mm) MAKE-IN 2 ,6 mm) WRENCH (38,1 mm) 3 FLATS 1 1/2" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP171 Page 3 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5T2-3/16" 7/16" (11,1 mm) 2-3/16" 4NOMINAL (55,6 mm) MAKE-IN 2 1-1/2" ,6 mm) WRENCH (38,1 mm) 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT 112"(12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU* NOMINAL 3/4„ PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON i 6*, 5_ 1/2" (12,7 mm) 2-5/16" 4 NOMINAL (58,7 mm) MAKE-IN (57,2 mm) (39,7 mm) 3 1 �3/4" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFP171 Page 4 of 10 7/16"(11,1 mm) SSU* NOMINAL 1/2" DEFLECTOR MAKE-IN NPT 6* 1, T I _T 57/ (55,6mm) 7/16" (11,1 mm) f 2-1/4" 4NOMINAL (57,2 mm) MAKE-IN 22-3/16" 1-9/16" WRENCH (39,7 mm) 3 FLATS 1 f SSP* Il CROSS 112" NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Technical O eration inch (1,6 mm) for the 135°F/57°C and N 3132 inch(2,4 mm)for the 286°F/141°C Data The glass Bulb contains a fluid that temperature ratings. expands when exposed to heat.When Obtain a leak-tight 112 inch NPT sprin- Approvals the rated temperature is reached, the kler joint by applying a minimum to UL and C-UL Listed fluid expands sufficiently to shatter the maximum torque of 7 to 14 ft.lbs. (9,5 FM, LPCB, and NYC Approved glass Bulb, allowing the sprinkler to to 19,0 Nm). Higher levels of torque Refer to Table A and B for complete activate and water to flow. can distort the sprinkler Inlet with con- approval information including sequent leakage or impairment of the corrosion-resistant status. Design sprinkler. Maximum Working Pressure Criteria not attempt to compensate for Refer to Table C. insufficient adjustment in the Escutch- eon Plate by under-or over-tightening Discharge Coefficient The TYCO Series TY-FRB Pendent the sprinkler. Re-adjust the position of K=2.8 GPM/psi1i2 (40,3 LPM/bar1/2) and Upright Sprinklers are intended the sprinkler fitting to suit. K=4.2 GPM/psi1i2 (60,5 LPM/bar1/2) for fire protection systems designed in The Series TY-FRB Pendent and accordance with the standard installa- K=5.6 GPM/psi1i2 (80,6 LPM/bar1/2) tion rules recognized by the applicable Upright Sprinklers must be installed K=8.0 GPM/psi1i2 (115,2 LPM/bar1/2) Listing or Approval agency(such as, UL in accordance with the following Temperature Rating Listing is based on the requirements of instructions. Refer to Table A and B. NFPA 13,and FM Approval is based on 1. Install Pendent sprinklers in the the requirements of FM's Loss Preven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10, sprinklers in the upright position. Sprinkler: Refer to Table A and B. 20,30,or 40 Recessed Escutcheon,as Recessed Escutcheon: White Coated, applicable, is to be used for recessed 2 With pipe-thread sealant applied to Chrome Plated, or Brass Plated. pendent installations. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Physical Characteristics Installation 3. Tighten the sprinkler into the sprin- Frame. . . . . . . . . . . . . . . . . . . Bronze kler fitting using only the W-Type 6 Button. . . . . . . . . . . . . .Brass/Copper The TYCO Series TY-FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly. . . . . . . . .Beryllium must be installed in accordance with reference to Figures 1 through Nickel w/Teflont the following instructions. 5, apply the W-Type 6 Sprinkler Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Wrench to the sprinkler wrench Compression Screw. . . . . . . . Bronze flats. Deflector. . . . . . . . . . .Copper/Bronze LEM Bushing (K=2.8) . . . . . . . . . . . Bronze Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter t Registered Trademark of Dupont of the air bubble is approximately 1116 TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K BULB LIQUID NATURAL CHROME WHITE*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) and 175°F/79°C Yellow 1,2,3,4 UPRIGHT(TY1131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 2,8 RECESSED 1/2"NPT PENDENT 155°F/68°C Red (TY1231)* 175°F/79°C Yellow Figure 6 200°F/93°C Green 135°F/57°C Orange 1 2 4 RECESSED PENDENT 155°F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79°C Yellow UPRIGHT(TY2131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F/68°C Red 1,2 (TY2231)" 175°F/79°C Yellow Figure 8 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** 175°F/79°C Yellow Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT(TY3231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F/93°C Green (TY3131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 5.6 PENDENT 175°F/79°C Yellow 1,2,4,5 N/A 1/2"NPT (TY3231)* Figure 10 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,4,5 N/A (TY3231)** Figure 11 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT(TY4231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F/93°C Green (TY4131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 8.0 PENDENT 175°F/79°C Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 12 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,5 N/A (TY4231)** Figure 13 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 8.0 PENDENT 155°F/68°C Red 1/2$NPT (TY4931)and 175°F/79°C Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F/93°C Green (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. "Installed with Style 10(112"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only. Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and (12,1 BAR) 5.6 UPRIGHT(TY3131) OR 105 PSI (11(12,BAR) 1/2"NPT (SEE NOTE 1) 1 BAR) RECESSED N/A PENDENT(TY3231) PENDENT(TY4231) 175 PSI and UPRIGHT(TY4131) (12,1 BAR) 8.0 175 PSI(12,1 BAR) 3/4"NPT RECESSED N/A PENDENT(TY4231) 8.0 PENDENT(TY4931) 175 PSI 1/2"NPT and 175 PSI(12,1 BAR) (12,1 BAR) UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent Care and Exercise care to avoid damage to Sprinklers must be installed in accor- sprinklers before, during, and after dance with the following instructions. installation. Never paint, plate, coat, 1. After installing the Style 10, 20, 30, Maintenance or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY-FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe-thread sealant applied to with the following instructions. . were modified or over-heated. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. • were damaged by dropping,striking, wrench twisting,wrench slippage,or 2. Tighten the sprinkler into the sprin- Before closing a fire protection system the like. kler fitting using only the W-Type 7 main control valve for maintenance . are leakingor exhibiting visible signs Recessed Sprinkler Wrench (Fig- work on the fire protection system g g ure 15). With reference to Figures 1 of corrosion. � g that it controls, obtain permission to to 4, apply the W-Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by-products with a cloth. ing, slide on the Style 10, 20, 30, or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY-FRB escutcheon, which is used to cover uid from the bulb. Refer to the Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. TFP171 Page 8 of 10 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" ' (3,2 mm) (3,2 mm) l MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. _ 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8 (73,0 mm) y 1/2"(12,7 mm) " (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) I 1 MOUNTING MOUNTING SURFACE SURFACE/ + CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 112 INCH NPT Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam- random samples are recommended for the inspection, testing, and mainte- age to the sprinklers -before, during, corrosion-resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam- the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has a cracked bulb or that has lost Inspections of corrosion-resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- Section). or range, instead of from the floor level sprinkler Contact the installing contractornkler manufacturer regarding any y Initial and frequent visual inspections of per NFPA. Inspection at close range spri random samples are recommended for can better determine the exact sprin- questions. corrosion-resistant sprinklers to verify kler condition and the long-term integ- Automatic sprinkler systems are rec- the integrity of the corrosion-resistant rity of the corrosion-resistant material, ommended to be inspected, tested, material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and/or national codes. TFP171 Page 9 of 10 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / (3,2 mm) (3,2 mm) 1 MOUNTING MOUNTING SURFACE SURFACE /I,/ CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. _ 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) I 1 MOUNTING MOUNTING71 I SURFACE SURFACE 4 11 CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT &0 K-FACTOR, 314 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range / WRENCH RECESS can better determine the exact sprin- (END"A" USED FOR kler condition and the long-term integ- 1/2" NPT MODELS) rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END"B" USED FOR 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH FIGURE 14 SPRINKLER WRENCHING AREA W-TYPE 6 SPRINKLER FIGURE 15 WRENCH W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX MODEL/SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 4 WHITE POLYESTER 155 155°F(68°C) 340 4.2K UPRIGHT(1/2"NPT) TY2131 3 WHITE(RAL9010)" 175 175°F(79°C) 341 4.2K PENDENT(1/2"NPT) TY2231 9 CHROME PLATED 200 200°F(93°C) 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.61K PENDENT(1/2"NPT) TY3231 390 8.OK UPRIGHT(3/4"NPT) TY4131 391 8.OK PENDENT(3/4"NPT) TY4231 360 8.OK UPRIGHT(1/2"NPT) TY4831' Eastern Hemisphere sales only. 361 8.OK PENDENT(1/2"NPT) TY4931` TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS responsible for sprinkler system design Limited ordering errors or inaccurate or incomplete infor- Warrant r supplied by Buyer or Buyer's procedure Y representatives. Products manufactured by Tyco Fire In no event shall TFSBP be liable, in Contact your local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to the any other legal theory, for incidental, indicate the full product name and Part original Buyer for ten(10)years against indirect,special or consequential dam- Number(P/N). defects in material and workmanship ages, including but not limited to labor when paid for and properly installed charges, regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of Thread Connections service. This warranty will expire ten such damages, and in no event shall Specify: (Specify Model/SIN), Quick (10) years from date of shipment by TFSBP's liability exceed an amount Response, (specify K-factor), (specify TFSBP. No warranty is given for prod- equal to the sales price. temperature rating), Series TY-FRB ucts or components manufactured by s ecif Pendent or Upright) Sprinkler companies not affiliated by ownership The foregoing warranty is made in lieu (specify with TFSBP or for products and com- of any and all other warranties,express with (specify type of finish or coating), ponents which have been subject to or implied, including warranties of mer- P/N (specify from Table D). misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: sion, or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify") accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify'). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and/or the standards of any other als or components,whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract,tort, strict liability or Specify: W-Type 6 Sprinkler Wrench, rials found by TFSBP to be defective any other legal theory. P/N 56-000-6-387. shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W-Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law.The invalidity, P/N 56-850-4-001. to assume for it, any other obligation in in whole or part, of any portion of this Refer to Technical Data Sheet TFP770. connection with the sale of products or warranty will not affect the remainder. parts of products.TFSBP shall not be Copyright©2007-2010 Tyco Fire Suppression&Building Products.All rights reserved. CO® Worldwide www.tyco-fire.com Contacts Series TY.B - 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the Description standard corrosion tests of the appli- The TYCO Series TY-B, 5.6 K-factor, cable approval agencies,the testing is Horizontal and Vertical Sidewall Sprin- not representative of all possible cor- klers described in this technical data rosive atmospheres. Consequently, sheet are standard response,standard it is recommended that the end user coverage decorative 5 mm glass bulb be consulted with respect to the suit- ttype spray sprinklers designed for use ability of these coatings for any given light and ordinary hazard, c for er-use corrosive environment. The effects of in light occupancies such as banks,hotels, ambient temperature,concentration of and shopping malls. chemicals, and gas/chemical velocity, should be considered, as a minimum, They are designed for installation along along with the corrosive nature of the a wall or the side of a beam and just chemical to which the sprinklers will be beneath a smooth ceiling. Sidewall exposed. sprinklers are commonly used instead of pendent or upright sprinklers due LEM to aesthetics or building construction The Series TY-B Sprinklers described considerations, where piping across herein must be installed and main- the ceiling is not desirable. tained in compliance with this docu- The recessed version of the Series ment, as well as with the applicable TY-B Horizontal Sidewall Sprinkler is standards of the National Fire Protec- intended for use in areas with a fin- tion Association,in addition to the stan- ished wall. It uses a two-piece Style 10 dards of any other authorities having Recessed Escutcheon. The Recessed jurisdiction.Failure to do so may impair Escutcheon provides 1/2 in. (12,7 mm) the performance of these devices. of recessed adjustment or up to 3/4 in. The owner is responsible for main- (19,1 mm) of total adjustment from the taining their fire protection system flush sidewall position.The adjustment and devices in proper operating con- provided by the Recessed Escutcheon dition. Contact the installing contrac- Maximum Working Pressure reduces the accuracy to which the fixed for or product manufacturer with any Refer to Table B pipe nipples to the sprinklers must be questions. Discharge Coefficient cut. K=5.6 gpm/psis/2(80,6 Ipm/bars/2) Corrosion-resistant coatings, where Sprinkler Temperature Ratings applicable,are utilized to extend the life of copper alloy sprinklers beyond that Identification Refer to Table A which would otherwise be obtained Finishes Nu M be rs Sprinkler: Refer to Table C TY3351. . . . . . . . Horizontal Sidewall Recessed Escutcheon:Signal or Pure IMPORTANT White,Grey Aluminum,Jet Black,Chrome Refer to Technical Data Sheet TY3451. . . . . . . . . . .Vertical Sidewall Plated,or Natural Brass TFP2300 for warnings pertaining to Physical Characteristics regulatory and health information. Technical Frame ............................Bronze Always refer to Technical Data Button......................Brass/Copper Sheet TFP700 for the "INSTALLER Data Sealing Assembly. Beryllium Nickel w/TEFLON WARNING" that provides cautions Bulb pressi .........................Glass p Approvals Compression Screw.......... ...Bronze with respect to handling and instal- UL and als Listed HSW Deflector .....................Bronze lation of sprinkler systems and com- UL Approved VSW Deflector..................... Copper ponents. Improper handling and FIVI LPCB Certified installation can permanently damage NYC Approved a sprinkler system or its compo- nents and cause the sprinkler to fail (Refer to Table A for complete approval to operate in a fire situation or cause information, including corrosion-resis- it to operate prematurely. tant status.) Page 1 of 6 JULY 2018 TFP161 TFP161 Page 2of6 DEFLECTOR \ DEFLECTOR 1 - Frame HAT �, \ 5 1 - Frame HAT 5 2 - Button � \ 2 - Button � 3 - Sealing 3 - Sealing Assembly Assembly 4 - Bulb 4 - Bulb 5 - Compression 5 - Compression Screw Screw 6 - Deflector* 6* 4 2 3 1 6 - Deflector* 6* 4 2 3 1 9/16" WRENCH 1/2"** 9/16" WRENCH 1/2" (14,3 mm) FLATS NPT (14,3 mm) FLATS NPT O _ O 1-13/16" 7/16" 1-13/16" 7/16" (46,0 mm) (11,1 mm) (46,0 mm) (11,1 mm) CENTERLINE NOMINAL CENTERLINE NOMINAL OF SPRINKLER MAKE-IN OF SPRINKLER MAKE-IN WATERWAY 1 1/2" WATERWAY 1-1/2" (38,1 mm) _ (38,1 mm) ESCUTCHEON ESCUTCHEON PLATE SEATING 2-3/16" _ PLATE SEATING 2-3/16" SURFACE (55,6 mm) SURFACE (55,6 mm) STYLE 10 STYLE 10 RECESSED RECESSED 1 ESCUTCHEON ESCUTCHEON *Temperature rating is *Temperature rating is indicated on Deflector indicated on Deflector jii ** Pipe thread connections per ISO 7-1 can be provided on special request 2-7/8" DIA. 2-7/8" DIA. (73,01 mm) (73,01 mm) 1 1 ALL FINISHES EXCEPT POLY-STAINLESS POLY-STAINLESS FINISH ONLY FIGURE 1 SERIES TY-B TY3351 HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR STANDARD RESPONSE Poly-Stainless Physical Characteristics Design Criteria Installation Frame ............................Bronze Button................ L316316 Stainless Steel` The TYCO Series TY-B, 5.6 K-fac- The TYCO Series TY-B, 5.6 K-factor, St Bulb...............................Glass tor, Horizontal and Vertical Side- Horizontal and Vertical Sidewall Sprin- Compression Screw..... L316 Stainless Steel` wall Sprinklers are intended for klers must be installed in accordance HSW Deflector ..............Copper/Bronze fire protection systems designed with this section. Sealing Assembly.Gold Plated Beryllium Nickel In accordance with the standard w/TEFLON installation YUIeS recognized by General Instructions *Type L316 stainless steel(UNS 31603)per ASTM YeCO n g A479/479M or BS EN 1008 WN1.4404. the applicable Listing or Approval Do not install any bulb type sprinkler agency (for example, UL Listing is if the bulb is cracked or there is a loss Operation based on the requirements of NFPA of liquid from the bulb. With the sprin- The glass bulb contains a fluid which 13, and FM Approval is based on the kler held horizontally,a small air bubble expands when exposed to heat.When requirements of the FM Loss Preven- should be present.The diameter of the the rated temperature is reached, the tion Data Sheets). Only the Style 10 air bubble is approximately 1/16 in. fluid expands sufficiently t0 Shatter the Recessed Escutcheon, as applicable, (1,6 mm)for the 135oF(57°C)to 3/32 in. glass bulb, allowing the sprinkler to is to be used for recessed horizontal (2,4 mm)for the 360 F(182 C)tempera- activate and water to flow. installations. ture ratings. TFP161 Page 3of6 *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection rating is connections 2 - Button 5 - Compression Spring indicated on per ISO 7-1 can 3 - Sealing Screw Deflector. be provided on Assembly 6 - Deflector* WRENCH RECESS special request. (END"A" USED FOR ARROW MUST 1/2" NPT MODELS) POINT AWAY 7/16" FROM AND BE FIGURE 4 ESCUTCHEON (11,1 mm) PERPENDICULAR O W-TYPE6 PLATE SEATING ** NOMINAL TO THE BACK /� SPRINKLER WRENCH SURFACE NPT MAKE-IN WALL SURFACE WRENCH 6* RECESS FLOW 52-3 (55,6/m", 2-3/16" 4 1 J 55,6 mm) 1-1/2" \ 2 (38,1 mm) WRENC FLATS 3 i PUSH WRENCH 1 IN TO ENSURE SHOWN SHOWN CROSS ENGAGEMENT PENDENT UPRIGHT SECTION WITH SPRINKLER FIGURE 2 WRENCHING AREA SERIES TY-B VERTICAL SIDEWALL(TY3451)SPRINKLER FIGURE 5 5.6 K-FACTOR, STANDARD RESPONSE W-TYPE 7 RECESSED SPRINKLER WRENCH 5/8 1/4" Horizontal Sidewall Sprinkler (15,9 6,4 mm) Installation FACE OF The TYCO Series TY-B Recessed Hor- MOUNTING izontal Sidewall Sprinklers must be SURFACE SPRINKLER installed in accordance with the fol- lowing instructions. Install recessed horizontal sidewall sprinklers in the horizontal position with the centerline CLOSURE of waterway perpendicular to the back wall and parallel to the ceiling. The 2-7/8" DIA. word "TOP" on the Deflector is to face SERIES (73,0 mm) towards the ceiling. - TY-B - 2-1/4" DIA. Step A. After installing the Style 10 (57,2 mm) Mounting Plate over the sprinkler threads,hand-tighten the sprinkler into MOUNTING - 11 the sprinkler fitting. PLATE Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 5). Apply the W-Type 7 Recessed Sprinkler Wrench to the (3,2 mm) sprinkler wrench flats(Ref. Figure 1). 1-1/4" (31,8 mm) 3/4"(19,1 mm) Step C.After the ceiling is installed or 3/4" (19,1 mm) 1/4"(6,4 mm) the finish coat is applied, slide on the Style 10 Closure over the Series TY-B FIGURE 3 Sprinkler and push the Closure over the SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Mounting Plate until its flange comes in WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT contact with the ceiling. STYLE 10 RECESSED ESCUTCHEON, 5.6 K-FACTOR, 112 INCH NPT A leak-tight 1/2 in. NPT sprinkler make-up for insufficient adjustment in joint should be obtained by apply- the escutcheon plate by under-or over- ing a minimum-to-maximum torque of tightening the sprinkler. Readjust the 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher position of the sprinkler fitting to suit. levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to TFP161 Page 4of6 Vertical Sidewall Sprinkler INOTim Automatic sprinklers must never be Installation painted, plated, coated, or other- The Series TY-B Vertical Sidewall Only retouching of the wax coating wise altered after leaving the factory. Sprinklers must be installed in accor- applied to the wrench flats and frame Modified sprinklers must be replaced. dance with the following instructions. arms is permitted, and the retouching Sprinklers that have been exposed to Install vertical sidewall sprinklers in the t i be performed only at the time of corrosive products of combustion, but pendent or upright position with the the initial sprinkler installation. have not operated,should be replaced arrow on the Deflector pointing away The steel rod should be heated only if they cannot be completely cleaned from the wall. to the point at which it can begin to by wiping the sprinkler with a cloth or Step 1. With pipe thread sealant melt the wax, and appropriate precau- by brushing it with a soft bristle brush. applied to the pipe threads, hand- tions need to be taken when handling Care must be exercised to avoid tighten the sprinkler into the sprinkler the heated rod in order to prevent the damage to the sprinklers before, fitting. installer from being burned. during, and after installation. Sprin- Step 2. Tighten the sprinkler into the Care and klers damaged by dropping, striking, sprinkler fitting using only the W-Type wrench twist/slippage,or the like, must 6 Sprinkler Wrench (Ref. Figure 4). For be replaced.Also,replace any sprinkler wax-coated sprinklers, use an 8 or 10 Maintenance that has a cracked bulb or that has lost in. adjustable Crescent wrench. Apply The TYCO Series TY-B, 5.6 K-factor, liquid from its bulb. (Refer to Installa- tionthe W-Type 6 Sprinkler Wrench or the Horizontal and Vertical Sidewall Sprin- Section.) Crescent wrench,as applicable,to the klers must be maintained and serviced The owner is responsible for the wrench flats(Ref. Figure 2). in accordance with this section. inspection,testing,and maintenance of When installing wax-coated sprinklers Before closing a fire protection system their fire protection system and devices with the adjustable Crescent wrench, main control valve for maintenance in compliance with this document, as well as with the applicable standards exercise care to prevent damage to the work on the fire protection system wax coating on the sprinkler wrench that it controls, obtain permission to of the National Fire Protection ion to flats or frame arms and, consequently, shut down the affected fire protection the s n standards N f a y of in addition to exposure of bare metal to the corro- system from the proper authorities the standards of any other authorities sive environment.Open the jaws of the and notify all personnel who may be having jurisdiction.Contact the install wrench sufficiently wide to pass over affected by this action. ing contractor or product manufacturer with any questions. the wrench flats without damaging the wax coating. Before wrench-tighten- The owner must assure that the sprin- Automatic sprinklers are recommended ing the sprinkler, adjust the jaws of the klers are not used for hanging any to be inspected,tested,and maintained wrench to contact only the sprinkler objects and that the sprinklers are only by a qualified Inspection Service in wrench flats. After wrench tightening cleaned by means of gently dusting accordance with local requirements the sprinkler, loosen the wrench jaws with a feather duster; otherwise, non- and/or national codes. before removing the wrench. operation in the event of a fire or inad- After installation, inspect the sprin- vertent operation may result. kler wrench flats and frame arms and Absence of an escutcheon, which is retouch(repair)the wax coating when- used to cover a clearance, may delay ever the coating has been damaged the time to sprinkler operation in a fire and bare metal is exposed. Retouch situation. the wax coating on the wrench flats by Sprinklers which are found to be gently applying a heated 1/8 in. diam- leaking or exhibiting visible signs of eter steel rod to the damaged areas of corrosion must be replaced. wax to smooth it back over areas where bare metal is exposed. TFP161 Page 5of6 SPRINKLER FINISH(10) K SPRINKLER TEMPERATURE QUIP WAX- TYPE RATING COLOR NATURAL CHROME POLYESTERS POLY- LEAD WAX OVER- BRASS PLATED STAINLESS° COATED COATED LEAD COATED 135°F(57°C) Orange 155°F(68°C) Red HORIZONTAL 175°F79°C Yellow 1,2,3,4,9 1,2,3,9 1,2,3,9 SIDEWALL ( ) 1,2 1,2,3,9 (TY3351) 200°F(93°C) Green Figure 1 5.6 286°F(141°C) Blue 11h,2b,3b,9b 1/2 in. NPT 360°F(182°C) Mauve 1,2,4,9 1,2,9 N/A RECESSED 135°F(57°C) Orange HORIZONTAL 155°F(68°C) Red SIDEWALL 1,2,3,9 1,2 N/A (TY3351)a 175°F(79°C) Yellow Figure 3 200°F(93°C) Green 135°F(57°C) Orange VERTICAL 155°F(68°C) Red SIDEWALL 5,6,7,9 5.6 (TY3451) 175°F(79°C) Yellow 4,5,6,7,8,9 N/A 1/2 in. PENDENT 5,6,7,9 NPT or 200°F(93°C) Green UPRIGHT Figure 2 286°F(141°C) Blue 5b,6b,7b,9b 360°F(182°C) Mauve 4,5,6,8,9 N/A N/A Notes: 1. UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector-to-ceiling distance 2. C-UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector-to-ceiling distance 3. FM Approved for use in Light Hazard Occupancies at a 4 to 12 IN.(100 to 300 mm)top of deflector-to-ceiling distance 4. LPCB Approved(Ref.No.094a&007k)at a 4 to 6 in.(100 to 150 mm)deflector-to-ceiling distance 5. UL Listed for use in Light and Ordinary Hazard Occupancies 6. C-UL Listed for use in Light and Ordinary Hazard Occupancies 7. FM Approved for use in Light Hazard Occupancies 8. -PCB Approved(Ref.No.094a&007k) 9. Approved by the City of New York under MEA 354-01-E 10.Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as corrosion-resistant sprinklers. a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only N/A-Not Applicable TABLE A SERIES TY-B HORIZONTAL AND VERTICAL SPRINKLERS LABORATORY LISTINGS AND APPROVALS SPRINKLER FINISH K SPRINKLER TYPE NATURAL CHROME POLYESTER' LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED HORIZONTAL SIDEWALL (TY3351) 250 psi(17,2 bar)2 OR 5.6 RECESSED 175 psi(12,1 bar) 1/2 in. HORIZONTAL SIDEWALL NPT (TY3351) VERTICAL SIDEWALL 175 psi(12,1 bar) (TY3451) Notes: 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to UL Listing,C-UL Listing and Approval by the City of New York TABLE B SERIES TY-B HORIZONTAL AND VERTICAL SPRINKLERS MAXIMUM WORKING PRESSURE TFP161 Page 6of6 P/N 57 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH I RATING 578 HORIZONTAL SIDEWALL TY3351 1 NATURAL BRASS 135 135°F(57°C) 575 VERTICAL SIDEWALL TY3451 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) Notes: 3 PURE WHITE(RAL9010)2 93°C°F 1. Available for TY3351 only POLYESTER 200 200 ( ) 2. Eastern Hemisphere sales only 4 SIGNAL WHITE(RAL9003) 3. Available only for 155 T(68°C)or 200 T(93°C)temperature POLYESTER rated sprinklers 286 286°F(141-C) 4. Available only for horizontal sidewall TY3351 for use in Deluge JET BLACK(RAL9005)3 Systems("OPEN'indicates sprinkler assembly without glass 5 POLYESTER 360 360°F(182°C) bulb,button,and sealing assembly) 6 WAX COATED 286°F(141 °C)MAX 000 OPEN4 7 LEAD COATED 8 WAX-OVER-LEAD 286°F(141 °C)MAX 9 CHROME PLATED TABLE C SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Color Sprinkler Part Number Temperature Rating Black 135°F(57°C) 56-065-1-135 Red 155°F(68°C) 56-065-1-155 Yellow 175°F(79°C 56-065-1-175 Blue 200°F(93°C) 56-065-1-286 286°F(141°C) TABLE D SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS WAX RETOUCHING STICK PART NUMBER SELECTION Li 1'n ited Sprinkler Assemblies with Wax Sticks NPT Thread Connections (for retouching wrench-damaged Warrant Specify: Series TY-13 (specify SIN), wax coating) Y (specify K-factor), (specify Horizontal Specify:(specify color,below)Colored For warranty terms and conditions,visit or Vertical Sidewall) Sprinklers with Coded Wax Stick for retouching www.tyco-fire.com. (specify) temperature rating, (specify) (specify temperature rating) tempera- finish or coating, P/N(Refer to Table C) ture-rated Series TY-13 Sprinklers, P/N Ordering Recessed Escutcheon (specify) Specify: Style 10 Recessed Escutch- Note: Each wax stick is suitable for Procedure eon with(specify)finish, P/N(specify*) retouching up to 25 sprinklers. Contact your local distributor for avail- *Refer to Technical Data Sheet TFP770 Note: The wax used for 286°F (141°C) ability.When placing an order, indicate Sprinkler Wrench sprinklers a the sameasthr200°F(93°C) the full product name and Part Number Specify: W-Type 6 Sprinkler Wrench, sprinklers,and,therefore,th me maxima ) (P/N). P/N 56-000-6-387 sprinkler is limited to the same maximum ceiling temperature as the 200°F(93°C) Specify: W-Type 7 Sprinkler Wrench, sprinkler(i.e., 150°F[66°C]). P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a reglstered trademark of DuPont tqCU Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB 5 . 6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response , Standard Coverage ment provided by the Recessed Es- General cutcheon reduces the accuracy to which the fixed pipe nipples to the De s c rip t i o n sprinklers must be cut. The Series TY-FRB, 5.6 K-Factor, Corrosion resistant coatings, where r Horizontal and Vertical Sidewall Sprin- applicable, are utilized to extend the �T klers described in this data sheet are life of copper alloy sprinklers beyond quick response - standard coverage, that which would otherwise be ob- decorative 3 mm glass bulb type spray tained when exposed to corrosive at- sprinklers designed for use in light and mospheres. Although corrosion resis- ordinary hazard,commercial occupan- tant coated sprinklers have passed the cies such as banks, hotels, shopping standard corrosion tests of the appli- malls, etc. They are designed for in- cable approval agencies,the testing is stallation along a wall or the side of a not representative of all possible cor- beam and just beneath a smooth ceil- rosive atmospheres. Consequently, it ing. Sidewall sprinklers are commonly is recommended that the end user be used instead of pendent or upright consulted with respect to the suitability ; sprinklers due to aesthetics or building of these coatings for any given corro- construction considerations, where sive environment.The effects of ambi- piping across the ceiling is not desir- ent temperature, concentration of - able. chemicals, and gas/chemical velocity, should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the " TY-FRB Horizontal Sidewall Sprinkler chemical to which the sprinklers will be is intended for use in areas with a exposed. finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch WARNINGS (12,7 mm) of recessed adjustment or The Series TY-FRB Sprinklers de- up to 3/4 inch(19,1 mm)of total adjust- scribed herein must be installed and ment from the flush sidewall position, maintained in compliance with this or a two-piece Style 20 Recessed Es- document, as well as with the applica- T e c h n 1 c a 1 cutcheon with 1/4 inch (6,4 mm) of ble standards of the National Fire Pro- recessed adjustment or up to 1/2 inch tection Association, in addition to the Da t c`i (12,7 mm)of total adjustment from the standards of any other authorities hav- flush sidewall position. The adjust- ing jurisdiction. Failure to do so may Approvals impair the performance of these de- UL and C-UL Listed. vices. FM, LPCB, and NYC Approved. The owner is responsible for maintain- (Refer to Table A for complete ap- ing their fire protection system and de- proval information including corrosion IMPORTANT vices in proper operating condition. resistant status.) The installing contractor or sprinkler Maximum Working Pressure Always refer to Technical Data manufacturer should be contacted Sheet TFP700 for the "INSTALLER with any questions. Refer to Table B. WARNING" that provides cautions Discharge Coefficient with respect to handling and instal- K= 5.6 GPM/psis/2 (80,6 LPM/barli2) lation of sprinkler systems and com- Model/Sprinkle r Temperature Ratings ponents. Improper handling and in- stallation can permanently damage Id e n t ifi c a t i o n Refer to Table A. a sprinkler system or its compo- Finishes nents and cause the sprinkler to fail Numbers Sprinkler: Refer to Table A. to operate in a fire situation or cause Recessed Escutcheon:White Coated, it to operate prematurely. TY3331 - Horizontal Chrome Plated, or Brass Plated. TY3431 - Vertical Page I of 6 APRIL, 2006 TFP176 Page 2 of 6 TFP176 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL I CHROME WHITE— LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,3,4,9, 10 1,2,3,9 1,2,3,9 (TY3331) 175°F/79°C Yellow 200°F/93°C Green 5.6 286°F/141°C Blue 1/2" NPT RECESSED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,4,9, 10 1,2,9 N/A (TY3331)* 175°F/79°C Yellow Figure 3 200°F/93°C Green RECESSED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,3,4,9 N/A (TY3331)" 175°F/79°C Yellow Figure 4 200°F/93°C Green VERTICAL 135°F/57°C Orange SIDEWALL 155°F/68°C Red 5.6 (TY3431) 5,6,7,8,9 5,6,7,9 1/2" Installed 175°F/79°C Yellow NPT Pendent 200°F/93°C Green or Upright 286°F/141°C I Blue NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 2.Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 4.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04)at a 4 to 6 inch (100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5.Listed by Underwriters Laboratories, Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6.Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06&007a/04)as Quick Response Sprinklers. 9.Approved by the City of New York under MEA 354-01-E. 10.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon. Installed with Style 20(1/2"NPT) 1/2"Total Adjustment Recessed Escutcheon. Frame and deflector only. Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Y Physical Characteristics @ Frame . . . . . . . . . . . . . Bronze Op era t i o n Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . The glass Bulb contains a fluid which . . . . . Beryllium Nickel w/Teflont expands when exposed to heat.When a Bulb . . . . . . . . . . . . . . . Glass the rated temperature is reached, the Compression Screw . . . . . Bronze fluid expands sufficiently to shatter the HSW Deflector . . . . . . . . Bronze glass Bulb, allowing the sprinkler to Of VSW Deflector . . . . . . . . Copper activate and water to flow. o Patents a. U.S.A. 5,810,263 0 TFP176 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3331) OR 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 5.6 RECESSED HORIZ. 1/2" SIDEWALL(TY3331) (SEE NOTE 1) N/A NPT VERTICAL SIDEWALL (TY3431) 175 PSI (12,1 BAR) NOTES: 1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories, Inc. (UL);the Listing by Underwriters Laboratories, Inc.for use in Canada(C-UL); and,the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE De s ign * Temperature rating is DEFLECTOR indicated on deflector or HAT [H. Cri t e ri a adjacent to orifice seat on frame. The Series TY-FRB Horizontal and **Pipe thread Vertical Sidewall Sprinklers are in- connections per ISO 7/1 tended for fire protection systems de- can be provided on \ signed in accordance with the stand- special request. and installation rules recognized by the 6 2 3 1 applicable Listing or Approval agency WRENCH 1/2"** (e.g., UL Listing is based on the re- 9/16" quirements of NFPA 13, and FM Ap- (14,3 mm) FLATS NPT proval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. 1-13/16" 7/16" (46,0 mm) 17 (11,1 mm) CENTERLINE NOMINAL OF SPRINKLER MAKE-IN WATERWAY 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) 1 -Frame STYLE ESCUTCHEON 2-Button PLATE SEATING 3-Sealing 10 or 20 Assembly RECESSED SURFACE 4-Bulb ESCUTCHEON 5-Compression Screw 6-Deflector 2-7/8"DIA. (73,0 mm) FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331)SPRINKLERS Page 4 of 6 TFP176 Ins t o Ha L i o n ARROW MUST POINT AWAY The Series TY-FRB Sprinklers must 7/16" FROM AND BE 0 be installed in accordance with the fol- ESCUTCHEON (11,1 mm) PERPENDICULAR lowing instructions: PLATE SEATING 1/2„** NOMINAL TO THE BACK NOTES SURFACE NPT MAKE-IN WALL SURFACE Do not install any bulb type sprinkler if *6 the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler 5 held horizontally, a small air bubble 2-3/16" 2-3116" should be present. The diameter of the (55,6 mm) (55,6 mm) 4 air bubble is approximately 1116 inch (1,6 mm) for the 135°F/57°C to 3132 1-1/2" WRENCH 2 inch (2,4 mm) for the 286°F/141°C (38,1 mm) FLATS �; A temperature ratings. 7 3 r, A leak tight 112 inch NPT sprinkler joint �+ should be obtained with a torque of 7 1 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- SHOWN SHOWN CROSS mum of21 ft. lbs. (28,5 Nm)of torque PENDENT UPRIGHT SECTION may be used to install sprinklers with 112 NPT connections. Higher levels of torque may distort the sprinkler and 1 -Frame 3-Sealing 4-Bulb 6-Deflector cause leakage or impairment of the 2-Button Assembly 5-Compression 7-Ejection Spring sprinkler. Screw Do not attempt to make-up for insuffi- cient adjustment in the escutcheon * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. plate by under- or over-tightening the **Pipe thread connections per ISO 7/1 can be provided on special request. sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 The Series TY-FRB Horizontal and 5.6 K-FACTOR QUICK RESPONSE Vertical Sidewall Sprinklers must be SERIES TY-FRB VERTICAL SIDEWALL (TY3431)SPRINKLERS installed in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- Step B.After installing the Style 10 or way perpendicular to the back wall and 20 Mounting Plate over the sprinkler Care a n d parallel to the ceiling.The word"TOP" threads, hand tighten the sprinkler into on the Deflector is to face towards the the sprinkler fitting. Ma In t e n a n C e ceiling. Step C. Tighten the sprinkler into the The Series TY-BFR Sprinklers must Vertical sidewall sprinklers are to be sprinkler fitting using only the W-Type be maintained and serviced in accord- installed in the pendent or upright po- 7 Recessed Sprinkler Wrench (Ref. ance with the following instructions: sition with the arrow on the Deflector Figure 6). With reference to Figure 1, pointing away from the wall. the W-Type 7 Recessed Sprinkler NOTES Step 2. With pipe thread sealant ap- Wrench is to be applied to the sprinkler Before closing a fire protection system plied to the pipe threads, hand tighten wrench flats. main control valve for maintenance the sprinkler into the sprinkler fitting. Step D. After the ceiling has been in- work on the fire protection system that Step 3. Tighten the sprinkler into the stalled or the finish coat has been ap- it controls, permission to shut down sprinkler fitting using only the W-Type plied, slide on the Style 10 or 20 Clo- the affected fire protection system 6 Sprinkler Wrench (Ref. Figure 5), sure over the Series TY-FRB Sprinkler must be obtained from the proper With reference to Figure 1 or 2, the and push the Closure over the Mount- authorities and all personnel who may W-Type 6 Sprinkler Wrench is to be ing Plate until its flange comes in con- be affected by this action must be no- applied to the wrench flats. tact with the ceiling tified. The Series TY-FRB Recessed Hori- The owner must assure that the sprin- zontal Sidewall Sprinklers must be klers are not used for hanging of any installed in accordance with the follow- objects; otherwise, non-operation in ing instructions. the event of afire or inadvertent opera- tion may result. Step A. Recessed horizontal sidewall Absence of an escutcheon, which is sprinklers are to be installed in the used to cover a clearance hole, may horizontal position with their centerline delay the time to sprinkler operation in of waterway perpendicular to the back a fire situation. wall and parallel to the ceiling. The word "TOP" on the Deflector is to face Sprinklers that are found to be leaking towards the ceiling. or exhibiting visible signs of corrosion TFP 176 Page 5 of 6 5/8±1/4" (15,9±6,4 mm) FACE OF Z(END ENCH RECESS MOUNTING SPRINKLER NPT MODELS) SURFACE FITTING FIGURE 5 CLOSURE W-TYPE 6 SPRINKLER WRENCH 2-7/8"DIA. (73,0 mm) WRENCH SERIES RECESS TY-FRB 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8" PUSH WRENCH (3,2 mm) IN TO ENSURE ENGAGEMENT 1-1/4"(31,8 mm) 3/4"(19,1 mm) WITH SPRINKLER WRENCHING AREA 3/4"(19,1 mm) 1/4"(6,4 mm) FIGURE 3 FIGURE 6 SERIES TY-FRB RECESSED HORIZONTAL S/DEWALL SPRINKLER W-TYPE 7 RECESSED WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT SPRINKLER WRENCH STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" must be replaced. (12,7±3,2 mm) Automatic sprinklers must never be painted, plated, coated or otherwise MOUNTING FACE OF altered after leaving the factory. Modi- SURFACE SPRINKLER fied sprinklers must be replaced. FITTING Sprinklers that have been exposed to corrosive products of combustion, but have not operated,should be replaced CLOSURE if they cannot be completely cleaned by wiping the sprinkler with a cloth or 2-7/8"DIA. by brushing it with a soft bristle brush. (73,0 mm) Care must be exercised to avoid dam- SERIES age to the sprinklers - before, during, TY-FRB 2-1/4"DIA. and after installation. Sprinklers dam- (57,2 mm) aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler MOUNTING that has a cracked bulb or that has lost PLATE liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- 1/8" ommended to be initially performed for (3,2 mm) corrosion resistant coated sprinklers, after the installation has been com- 1-1/4"(31,8 mm) 1/2"(12,7 mm) pleted,to verify the integrity of the cor- rosion resistant coating. Thereafter, 1"(25,4 mm) 1/4"(6,4 mm) annual inspections per NFPA 25 should suffice; however, instead of in- FIGURE 4 specting from the floor level,a random SERIES TY-FRB RECESSED HORIZONTAL S/DEWALL SPRINKLER sampling of close-up visual inspec- WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT tions should be made, so as to better STYLE 20 RECESSED ESCUTCHEON determine the exact sprinkler condi- tion and the long term integrity of the Page 6 of 6 TFP176 P/N 57 - XXX - X - XXX SPRINKLER TEMPERATURE MODEL/SIN RATING 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F/57°C 375 VERTICAL SIDEWALL TY3431 4 WHITE POLYESTER 155 155°F/68°C 3 WHITE RAL9010)* 175 175°F/79°C 9 CHROME PLATED 200 200°F/93°C 7 LEAD COATED 286 286°F/141°C TABLE C 'Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS corrosion resistant coating, as it may standards of any other Authorities be affected by the corrosive conditions Having Jurisdiction. Materials found Ord e rin g present. by TFBP to be defective shall be either repaired or replaced, at TFBP's sole Procedure The owner is responsible for the in- option. TFBP neither assumes, nor spection, testing, and maintenance of authorizes any person to assume for it, When placing an order, indicate the their fire protection system and de- any other obligation in connection with full product name. Refer to the Price vices in compliance with this docu- the sale of products or parts of prod- List for complete listing of Part Num- ment, as well as with the applicable ucts.TFBP shall not be responsible for bers. standards of the National Fire Protec- sprinkler system design errors or inac- Contact your local distributor for avail- tion Association (e.g., NFPA 25), in curate or incomplete information sup- ability. addition to the standards of any other plied by Buyer or Buyer's repre- authorities having jurisdiction. The in- sentatives. Sprinkler Assemblies with NPT stalling contractor or sprinkler manu- In no event shall TFBP be liable, in Thread Connections: facturer should be contacted relative contract, tort, strict liability or under Specify: (Specify Model/SIN), Quick to any questions. any other legal theory, for incidental, Response, (specify K-factor), (specify It is recommended that automatic indirect,special or consequential dam- temperature rating), Series TY-FRB sprinkler systems be inspected, ages, including but not limited to labor (specify Horizontal Sidewall or Vertical tested, and maintained by a qualified charges, regardless of whether TFBP Sidewall) Sprinkler with (specify type Inspection Service in accordance with was informed about the possibility of of finish or coating), P/N (specify from local requirements and/or national such damages, and in no event shall Table C). codes. TFBP's liability exceed an amount equal to the sales price. Recessed Escutcheon: Specify: Style (10 or 20) Recessed Lim i t e d The foregoing warranty is made in lieu Escutcheon with (specify*) finish, P/N of any and all other warranties. ex- (specify*). Wa rra n t y press or implied, including warranties of merchantability and fitness for a par- *Refer to Technical Data Sheet TFP770. Products manufactured by Tyco Fire& ticular purpose. Building Products (TFBP) are war- This limited warranty sets forth the ex- Sprinkler Wrench: ranted solely to the original Buyer for clusive remedy for claims based on Specify: W-Type 6 Sprinkler Wrench, ten (10)years against defects in mate- failure of or defect in products, materi- P/N 56-000-6-387. rial and workmanship when paid for als or components, whether the claim Specify: W-Type 7 Sprinkler Wrench, and properly installed and maintained is made in contract, tort, strict liability P/N 56-850-4-001. under normal use and service. This or any other legal theory. warranty will expire ten (10) years from date of shipment by TFBP. No This warranty will apply to the full ex- warranty is given for products or com- tent permitted by law.The invalidity, in ponents manufactured by companies whole or part, of any portion of this not affiliated by ownership with TFBP warranty will not affect the remainder. or for products and components which have been subject to misuse,improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale, Pennsylvania 19446 AIR PRODUCTS OL Plus Series - Single Phase, Riser Mounted Air Compressors for Dry Pipe Sprinkler Systems O L UThis oil less riser mounted air compressor is UL1450 listed - oL Series for use in sprinkler systems. - UL1450 listed - Integrated Air Intake Filters - Oil Less Piston Compressor - Fully automatic, direct drive - UL Listed Pressure Switch - Max Pressure: 60 PSI - Bubble tight air check valve - 30" Stainless Steel Flex Hose - Permanently lubricated bearings - Riser Mounting Kit - Specifically designed to fill the sprinkler system to 40 PSI in 30 minutes MotorSystem Model Average 125 gal. OL12516AC 1.52 1/6 12 16" 12" 12" 30 250 gal. OL25033AC 3.03 1/3 12 16" 12" 12" 31 365 gal. OL36550AC 4.43 1/2 12 16" 15" 101, 38 430 gal. OL43075AC 5.21 3/4 10 17" 15"' 101, 48 615 gal. OL615100AC* 7.46 1 6 17" 15" 10" 48 915 gal. OL915150AC* 11.10 1 1/2 6 23" 15" 101, 60 1225 gal. OL1225200AC* 14.85 2 10 24" 15" 11" 70 Accessories: Notes: Air Maintenance Device- Part#AMD-1 + System Capacity based on 70°F system temperature. The AMD-1 regulates the volume of air being delivered ** Average CFM is the average free air delivery from q to the sprinkler system by the air compressor. 0 to 40 PSIG a Per NFPA 13-An Air Maintenance Device is required ++ Recommended Wire Sizes based on 100ft run. on every system unless the air compressor has a capacity less than 5.5 ft3/min at 10 psi. consult factory for longer or shorter runs. * Compressor has a capacity above 5.5 CFM at 10 PSI. Motor Line Starters - Thermal Overload Protection Air Maintenence Device required per NFPA 13 Single Phase VOLTAGE-All Single Phase Units 115 or 208-230 Volt 115V 208/230V Size Model except OL1225200AC which is 208-230 only. 1/3 HP 1 HP 00 MGOOA Maximum 1 HP 2 HP 0 MGXOA QO H 2 HP 3 HP 1 MG01A 3 HP 5 HP 1P MG15A When Ordering a Motor Starter you must specify HP, Voltage - —� and Phase that is supplied to the motor. ®WARNING:Cancer and Reproductive Harm-www.o65wamings.ca.gov www.generalairproducts.com 1-800-345-8207 AIR PRODUCTS OL Plus Series - Single Phase Riser Mounted Fire Protection Air Compressor Electrical Cut Sheet OLThis oil less riser mounted air U� UL compressor is UL1450 listed Series for use in sprinkler systems. Factory Amperage (amps) Recommended ize .Model Nominal Wired Based on Run . . . - VoltageNumber HP Up 115 5 35 12 12 12 OL12516AC 1/6 115 208 2.3 16.1 12 12 12 230 2.5 17.5 12 12 12 115 7.4 51.8 12 12 8 OL25033AC 1/3 115 208 3.5 24.5 12 12 12 230 3.7 25.9 12 12 12 115 10 70 12 10 8 OL36550AC 1/2 115 208 4.9 34.3 12 12 12 230 5 35 12 12 12 115 11.6 81.2 12 10 6 OL43075AC 3/4 115 208 5 35 12 12 12 230 5.8 40.6 12 12 12 115 18 126 12 8 6 OL615100AC 1 115 208 7.7 53.9 12 12 12 230 9 63 12 12 12 115 16.6 116.2 12 8 6 OL915150AC 11/2 115 208 8.2 57.4 12 12 12 230 8.3 58.1 12 12 12 OL1225200AC 2 208-230 208 11.6 81.2 12 12 10 230 11 77 12 12 10 Note: Wire sizes are based on maintaining 90%of the nominal voltage at starting amps. Starting amps are assumed to be 6 times the SFA. Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor. Wire sizes listed are recommendations only. Consult the National Electric Code(NEC)and any applicable local electrical safety codes.The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code(NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 7 w A/R PRODUCTS OL Plus Series - Connection Diagram OA ' This oil less riser mounted air Z1�� UL compressor is UL1450 listed - Series for use in sprinkler systems. _ System Layout PRESSURE SWITCH MUST or. BE WIRED IN CIRCUIT TO INDUSTRIAL CONTROL COMPRESSOR Main DISCONNECT SWITCH Power 9 OFT WIRE RUN, TOTAL LENGTH RISER NOTES: 1.MOST MOTORS ARE MULTIPLE VOLTAGE.CHECK NAME PLATE FOR CORRECT INTERNAL CONNECTIONS FOR VOLTAGE BEING SUPPLIED TO UNIT. 2.ALL WIRING TO BE IN ACCORDANCE WITH THE APPLICABLE STATE.LOCAL,AND NATIONAL CODES SHOULD BE APPROVED BY AHI. AIR TO SYSTEM Pressure Switch Connection SWP60401 U-C SWP60601 U PRESSURE SWITCH for 1/6 - 1/2 HP for 3/4-2 HP POWER SUPPLY Diagram +�� M. . L23Note:Location of pressure switch varies based on Ll L2model.This is a general diagram of components.For Ehelp specific to your switch please contact General Air POWERProducts. I41 iSUPPLY RT2L2 aB Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor. Wire sizes listed are recommendations only. Consult the National Electric Code (NEC)and any applicable local electrical safety codes.The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code (NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 Fire SprinkLer Accessories 'I mc. Engineered Solutions Fire Department Connection — S.Og|e C|apper, Siamese Straight Specifications �� 09_000 Size:— 4^|PSOutlet (2)z8^Inlets Straight Pattern Material: � 4r �� �� alaerao~ � Finishes: Rough Brass ' poi|shed[hmme^^ � Pin Lugs: msT I0686x716T ecr s.0000xurp [F 2.9900x716T Om-new I0580x6TP Om-old 3.0930x0TP [cv 3.0780x8Tp Dayton I2340x6Tp DcT 3l250x7*T Description wovascoa.zaooxsTP m,po 3.0300x8Tp The Straight Pattern Fire Department Connection isUL Listed and FMApproved. OmT 3l250x5Tp Manufactured from solid brass*components to increase service Life.The single clapper pHx aoszoxaTP design features brass clapper and brass seats within a cast brass body.The 2'/2"inlets QST 3.0910x7Tp are pin Lug design for ease of use and compatibility with Local fireservice districts.Swivel Raleigh 3.3400»6Tp nichmona.slznxuTp gaskets are included.Breakable caps orplugs should be installed to protect threads and TsM 3.0750x6Tp prevent debris from being accidently introduced into the water way. App,ovab: InstalLation uL Listed aoop,i Installation of the Fire Department Connection is achieved with readily available jobsite pw Approved 900pg ^ tools.Prior to installation make sure the proper idend cation sign has been instaK c"","/"`�°^ w"tm,""°m°°,°,`,,,°m`/",°"^°dedonthe for hu man nipple.Coat male threads of4^|PS nipple Liberally with a suitable pipe thread sealant such ^Polished chrome n1sh only available for mST pin lugs. aspipeph'.Tighten FDC one full turn past hand tight.Make sure Fo[is aligned according to requirements. & <�> D0 NOT OVER TIGHTEN.0VERT|CHTEN|NG MAY CAUSE SEVERE STRETCHING AND LISTED— APPROVED -- POSSIBLE CRACKING OF THE OF THE FD[BODY. The information above/^believed wbe reliable and accurate,but meant for reference only.ppp/and its agents cannot be hew FPPI. responsible",liable for incidental ,consequential damages°,toss suffered by any person","result ofm"use",misuse"f""~f m./"m�*""=��m"*�"��="°w�m.m"�=u"�u��"""���"^our=���**t�"��,=�",/mow ImAnAS[Engineered Solution w assure that products and methods cruse are suitable w,w°intended purpose,and the preparation vrio,w installation,and the installation*executed properly and"="*m^t°existing code,regulations where applicable and accepted industry practices.nyo"are =**rai"*=the installation mth/,product,seek guidance from"n""uedinstaller. PROJECT INFORMATION APPROVAL STAMP Project: El Approved Address: El Approved as noted Contractor: F-1 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Fp-oszz page I pp'soo'09'000'0120220502 tqCOWorldwide Fire Protection Contacts www.tyco-fire.com Products Model AMP-1 Automatic Air Maintenance Device Pressure Reducing Type with Field-Adjustable Pressure Regulator General Technical Description Data The TYCO Model AMD-1 Automatic Air Approvals Maintenance Device is an automatic, UL and C-UL Listed _ field-adjustable, pressure reducing FM Approved device. It is used to control the pres- NYC Approved under MEA 206-02-E sure in a dry pipe sprinkler system,pre- Maximum Inlet Air(or Nitrogen) action system, or dry pilot line system Supply Pressure of a dry pilot actuated deluge or preac- 200 psi(13,8 bar) tion valve. IF' Field-Adjustable Outlet Pressure The Model AMD-1 Device is utilized Range in applications where there is a com- 5 to 70 psi(0,4 to 4,8 bar) pressed air (or nitrogen) source con- trolled at a higher pressure than the Assembly desired system pressure. Pressure Major components illustrated in Figure sources include plant air supplies with 1 are factory assembled with galva- Installation their own automatic compressor con- nized steel nipples and malleable iron trols or nitrogen supplies with single- pipe fittings. The TYCO Model AMD-1 Automatic stage, cylinder-mounted pressure Air Maintenance Device should be regulators. operation installed in the horizontal position as The Model AMD-1 Automatic Air Main- shown in figure 1, as well as in accor- tenance Device is a re-designation for The By-Pass Valve in the Model AMD-1 dance with the following instructions: the Central Model D-2, Gem Model Automatic Air Maintenance Device is F324, and Star Model S460. opened to quickly fill the system during freTRIM initial pressurization.Once the required Moisture build-up can adversely affect system pressure has been reached, performance. Suitable consideration ® the By-Pass Valve is closed and the must be given to the removal of exces- The Model AMD-1 Automatic Air Main- Air Supply Control Valve is left open to sive moisture from the compressed air tenance Devices described herein must place the Model AMD-1 Device in auto- supply. be installed and maintained in compli- matic operation. ance with this document and with the When there is a small leak in the 1. Make connections a minimum of applicable standards of the National system, the Pressure Regulator auto- 1/2 inch (DN15) pipe size between Fire Protection Association, in addi- matically maintains system pressure at the inlet air supply and the Model tion to the standards of any authorities the preset level.The 3/32 inch(2,4 mm) AMD-1 Device,as well as between l. having jurisdiction. Failure to do so orifice in the 1.The ctor Check Valve the Model AMD-1 Device and the may impair the performance of these limits the flow of air from the Pressure system to pressurize. devices. Regulator into the system to a value 2. Place a 1/2 inch(DN15),non-spring Owners are responsible for maintain- significantly less than that exhausted loaded, rubber-faced, swing-type ing their fire protection system and by the operation of a 5.6 K-factor check valve between the Model devices in proper operating condition. sprinkler. AMD-1 Device and the system to The installing contractor or sprinkler pressurize. A check valve of this manufacturer should be contacted type is provided in the air supply with any questions. trim of TYCO dry pipe valves, pre- action valves, and dry pilot trim. Page 1 of 4 AUGUST 2015 TFP1221 TFP1221 Page 2 of 4 2" 16-1/8"" _ (50,8 mm) (409,6 mm) 1/4" NPT BY-PASS VALVE GAUGE (NORMALLY TEST PORT CLOSED) V(82 4" 112" NPT P/N 46-047-1-004 mm) OUTLET CONNECTION (TO SYSTEM) 8-1/2" (215,9 mm) 1/2" NPT LABEL INLET CONNECTION (FROM COMPRESSED AIR SUPPLY) RESTRICTOR � � � i CHECK VALVE P/N 92-326-1-003 PRESSURE AIR SUPPLY REGULATOR STRAINER CONTROL VALVE (ADJUSTABLE) P/N 52-353-1-002 (NORMALLY OPEN) P/N 92-324-1-012 P/N 46-048-1-002 FIGURE 1 MODEL AMD-1 AUTOMATIC AIR MAINTENANCE DEVICE Setting 6. Open the Air Supply Control Valve 10. Open the control valve in the in the Model AMD-1 Device. air supply trim to the system to Procedure 7. While observing the relocated pressurize. pressure gauge, adjust the output 11. Open the Air Supply Control Valve The TYCO Model AMD-1 Automatic pressure of the Pressure Regula- in the Model AMD-1 Device. Air Maintenance Device must be tor. Pull the knob out and away 12. Open the By-Pass Valve in the set in accordance with the following from the Pressure Regulator body Model AMD-1 Device. instructions: and then slowly turn the knob 1. Determine the pressure that meets clockwise, as viewed from the 13. Close the By-Pass Valve after the the minimum requirements of the knob end of the Pressure Regu- system is pressurized to approxi- system to pressurize. lator, to increase pressure, and mately 5 psi(0,4 bar)less than the counter-clockwise to decrease minimum required system pres- 2. Close the Model AMD-1 By-Pass pressure. sure determined in Step 1. Valve,and close the Model AMD-1 When decreasing pressure,the air 14. After the system pressure sta- Air Supply Control Valve. pressure must be relieved down- bilizes, note the value and com- 3. Open the control valve in the air stream of the Pressure Regulator pare with the requirement. Re- supply trim of the system to pres- by temporarily opening the control adjust the Pressure Regulator, as surize and then reduce the system valve in the air supply trim of the required. air pressure to 0 psi. system to pressurize,assuming that 4. Close the control valve in the the system to pressurize is at 0 psi. LEM air supply trim of the system to After the Pressure Regulator is set, If the system was over-pressurized pressurize. push the knob in and towards the during manual fill, open a suitable 5. Remove the system pressure Pressure Regulator body to"snap" connection to the system and manu- gauge from its connection and it in a locked position. ally reduce the pressure to the desired temporarily install it in the 1/4 inch 8. Close the Air Supply Control Valve value. The Model AMD-1 Automatic Air NPT Model AMD-1 Gauge Test in the Model AMD-1 Device. Maintenance Device then automatically Port. maintains the preset system pressure. 9. Return the system air pressure The Restrictor Check Valve prevents gauge to its normal location. Re- the Pressure Regulator from bleeding install the 1/4 inch pipe plug in the down the system pressure. Before removing the plug,make certain Model AMD-1 Gauge Test Port. In order to minimize the time for system that the piping to which the Model Apply pipe-thread sealant spar- trip in the event of a sprinkler opera- AMD-1 Gauge Test Port is connected ingly to the plug threads only. tion, set the system pressure at the is at 0 psi. Failure to do so may result minimum required value. in personal injury or property damage. RM-17WRO in Before removing the pressure gauge, make certain that the piping to which the Model AMD-1 Gauge Test Port is connected is at 0 psi. Failure to do so may result in personal injury or prop- erty damage. TFP1221 Page 3of4 Care and Automatic sprinkler systems are rec- Limited ommend to be inspected, tested, Maintenance and maintained a qualified c Warranty Inspec- tion Service in accordance withth local The TYCO Model AMD-1 Automatic requirements and/or national code. For warranty terms and conditions,visit Air Maintenance Device must be main- The Model AMD-1 Device must be www.tyco-fire.com. tained and serviced in accordance with inspected quarterly in accordance with the following instructions,in addition to the following instructions: ordering any specific requirements of the NFPA. Any impairment must be immediately 1. Verify that the By-Pass Valve is closed. procedure corrected. 2. Close the Model AMD-1 Air Supply Contact your local distributor for avail- MUM Control Valve and clean out the 1/4 ability. When placing an order, indi- Before closing a fire protection system inch Strainer located at the inlet cate the full product name, including main control valve for maintenance to the Restrictor Check Valve. Be description and Part Number(P/N). work on the fire protection system sure to reinstall the strainer screen Model AMD-1 Device that it controls, obtain permission to er and tighten the cap securely. p Specify: Model AMD-1 Automatic Air shut down the affected fire protec- 3. Open the Model AMD-1 Air Sup- Maintenance Device,P/N 52-324-2-002 tion system from the proper authori- ply Valve and verify that the control ties and notify all personnel who may valve in the air supply trim to the Replacement Parts be affected by this action. system to pressurize is open. Specify:(description), P/N(specify per It is recommended that accumulated 4. Verify that the system pressure is Figure 1) moisture be removed from air supply essentially the same as the previ- moisture filtration equipment at least ously established requirement. If quarterly. More frequent inspections not, adjust the system pressure may be necessary in particularly humid as follows: environments. a. Close the system's main con- After placing a fire protection system trol valve and open the main in service, notify the proper authori- drain valve. If the system is so ties and advise those responsible for equipped, close the Accelera- monitoring proprietary and/or central for Control Valve. station alarms. b. Follow Steps 1 through 14 in Responsibility lies with owners for the the Setting Procedure section. inspection,testing,and maintenance of c. Slowly open the Accelerator their fire protection system and devices Control Valve, as applicable. in compliance with this document, as well as with the applicable standards of d. Slowly open the main con- the National Fire Protection Association trol valve. After water begins (for example, NFPA 25), in addition to to flow, slowly close the main the standards of any other authorities drain valve, then completely having jurisdiction.Contact the install- open the main control valve. ing contractor or sprinkler manufac- The Model AMD-1 Automatic turer regarding any questions. Air Maintenance Device is now ready for service. TFP1221 Page 4of4 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. tgg0 Fire Protection Products ES-A-Deringer 30 Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval — Representative DeringerTM 30 Double Check Detector Assembly 4. . Sizes: 2"** - 8" a The DeringerTM 30 Double Check Detector Assembly(DCDA-ll) • • ,, prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire Approved for Fire Protection,Waterworks, Plumbing, sprinkler systems when monitoring of unauthorized water and Irrigation Applications. use is required. Materials Features Valve Housing: 304 Stainless Steel •Integral shutoff valves indoor/outdoor application Valve Cover: 304 Stainless Steel •100%stainless steel housing SOV Disks: EPDM/304SS •Tamper-resistant test cocks SOV Shafts: 304 Stainless Steel •Patented Dual-actionTm check modules Bypass Spring 302 Stainless Steel - Poppet action at low flow SOV Bearings: Teflon®fluoropolymer/Bronze -Swing action at high flow Non-wetted Bolts: Grade 8 Zinc Plated •Lead Free* Bronze bypass components Check Disks: Silicone(NSF) •CuFt or gallons bypass meter Wetted Fasteners: 18-8 Stainless Steel •DCDA-II single check bypass Bypass Components: Lead Free Bronze •Silicone elastomer check discs Check Springs: 17-7 Stainless Steel •Prewired supervisory switches Check Pins: 17-7/18-8 Stainless Steel •Flange adapters available Check Seats: Noryl® Polymer(NSF) •IPS grooved ends O-rings: Buna-N (NSF) Bypass Internals: ABS Polymer(NSF) Specifications Pressure — Temperature The Deringer 30 Double Check Detector Assembly shall utilize two independent Dual-action check modules and two integral Temperature Range:33°F-140°F resiliently seated shut-off valves all of which shall be contained Working Pressure: 10-175psi within a single rigid valve housing constructed entirely of 304 stainless steel. Both integral shutoff valves shall include *The wetted surface of this product contacted by consumable pre-wired supervisory tamper switches contained within a water contains less than 0.25%of lead by weight. weatherproof actuator housing approved for both indoor and outdoor use. Dual-action check modules shall operate as a Teflon®is a registered trademark of The Chemours Company. "poppet style"check under low flow conditions, operate as Nory10 is a registered trademark of SABIC Global Technologies B.V. a"swing style"check under high flow conditions and utilize replaceable silicone elastomer sealing discs.Assembly test ONFiToTMM cocks shall be handle-less and operate via a tamper resistant The information contained herein is not actuator.Assembly shall have a single full access service port intended to replace the full product installa- and cover with an "inline" replaceable elastomer seal. The tion and safety information available or the bypass assembly shall include a meter registering either experience of a trained product installer.You gallons or cubic feet, a single check valve and required test are required to thoroughly read all installation cocks.Assembly shall be serviceable without special tools and instructions and product safety information approved for both horizontal and vertical applications. before beginning the installation of Ak this product. A M Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- E S. ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction, FIRE&WATERWORKS specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand = Rated Flow A=UL Tested O = 15 fps Flow Performance _ (Ipm) 379 757 1136 1514 1893 2271 2650 3028 18 124 a 16 2„/2„ 4" 110 14 3" 96 12 83 J 10 69 8 55 6 41 cn 4 28 2 14 a� 0 (kPa) 0 100 200 300 400 500 600 700 800 Specific orientation&agency flow characteristics available on website Rate of Flow (gpm) pm) 1514 3028 4542 6056 7571 9085 16 110 a 14 6 8" 96 12 83 0 10 69 J 8 55 6 41 4 28 2 14 a� 0 400 800 1200 1600 2000 2400 *Specific orientation&agency flow characteristics available on website Rate Of Flow (gpm) Standards AWWA C510-07 Compliant NSF/ANSI 372, UL CERTIFIED LEAD FREE Dimensions - Weights End Connections - IPS Groove for Steel Pipe: AWWA C606 - Flange Adapters: ANSI B16.1 Class 125 ssfF� Ht D H ®C US APPROVED AssE U SC � O �Hb APPROVED 1015 L W Size Model 2(2'/2)** 30 7.1 180 2.9 74 22.3 566 0.0 0 10.0 254 11.0 279 52 24 2'/2 30 7.1 180 2.9 74 18.7 475 0.0 0 10.0 254 11.0 279 47 21 3 30 7.4 188 2.9 74 18.7 475 0.0 0 10.3 262 11.0 279 49 22 4 30 7.9 201 3.1 79 18.7 475 0.2 5 11.0 279 11.0 279 51 23 6 30 10.1 257 4.5 114 25 726 1.0 25 14.6 370 16.9 429 99 45 8 30 10.4 264 5.4 137 31.0 787 1.8 46 15.8 401 13.8 351 150 68 **2"size utilizes a 2 1/2"assembly with 2 1/2"groove to 2"female NPT adapter and couplings.Adapter and couplings ship unassembled. AM E S FIRE&WATERWORKS A WATTS Brand USA:Backflow T:(978)689-6066•F:(978)975-8350•AmesFireWater.com USA:Control Valves T:(713)943-0688•F:(713)944-9445•AmesFireWater.com Canada: T:(905)332-4090•F:(905)332-7068•AmesFireWater.ca Latin America: T:(52)55-4122-0138•AmesFireWater.com ES-A-Deringer 30 1951 0 2020 Watts t t tllll &64mmys 20184019 � + Product Catalog Ap TABLE OF CONTENTS Sammys°for Wood .......................................................................................................................... 4 Sidewinder"for Wood....................................................................................................................... 5 Sammys Swivel Head" for Wood......................................................................................................5 Sammys°for Steel............................................................................................................................ 6 Sidewinder"for Steel........................................................................................................................ 7 Sammys Swivel Head'm for Steel....................................................................................................... 7 SammyX-PressO............................................................................................................................... 8 SammyX-Press SidewinderTM............................................................................................................ 8 SammyX-Press Swivel'm................................................................................................................... 9 Sammy X-Press It° Installation Tool ..................................................................................................9 Sammys°for Concrete................................................................................................................... 10 Sidewinder"for Concrete ................................................................................................................ 10 Sammys Swivel HeadT11 for Concrete................................................................................................11 Concrete/Wood Installation Kit........................................................................................................ 11 SammysToggleTM............................................................................................................................ 12 Dektite° Pipe Flashing..................................................................................................................... 12 Sammys X-Press° Pole Tool Kit...................................................................................................... 13 SammysPole TooITM......................................................................................................................... 13 Approvalsand Listings.................................................................................................................... 14 SpecialNotes .................................................................................................................................. 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used.Allowance for special characteristics in materials,differences in materials,differences in types of materials being joined,unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered.Due to possible differences in specifications,applications,and interpretation of results,purchasers and specifiers must make their own evaluation of the products,to determine the suitability of these products for intended use.All warranties of Buildex products,expressed or implied,including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following:Buildex will repair or replace any product which,within twelve months after sale by Buildex or its distributors,is found by Buildex to be defective in material or workmanship-normal wear and tear accepted.This is the sole warranty of Buildex and the sole remedy available to distributor or buyer.Buildex shall not be liable for any injury,loss or damage,direct,indirect,or consequential,arising out of the use of,or the inability to use,any Buildex product. INSTALLATION • • ' WOOD & STEEL INSTALLATION STEP INTO WOOD&STEEL: INSTALLATION STEP •' •MTO WOOD&STEEL: 1.Insert the appropriate nut driver into a 318"or 1/2°portable drill. 1.Insert the appropriate nut driver into a 318"or 112"portable drill. 2.Insert the SAMMYS®into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.Begin installation when the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins freely on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114"318",112"or metric all thread rod,bolt stock.(The 112"requires the#14SW red nut driver) 4.The unit is now ready to receive 114",318",M10,M8 or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximumpullout in purlin steel. Note:When installing SWDR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximum pullout in purlin steel. INSTALLATION • FOR CONCRETE INSTALLATION STEPS- =INTO CONCRETE: INSTALLATION STEPS = INTO CONCRETE: 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit,pre-drill the concrete member to a depth of 2"with a carbide tip bit,pre-drill the concrete member to a depth of 2"with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2.After pre-drilling has been completed,install the SLEEVE TOOL over 2.After pre-drilling has been completed,install the SLEEVE TOOL the bit(the bit should remain in the drill),and insert the#14(black) over the bit(the bit should remain in the drill),and insert the#14SW(red) nut driver(p/n 8113910)into the opposite end(see Vertical Installation nut driver(p/n 8114910)into the opposite end. note above). 3.Insert the SWC screw into the nut driver. 3.Insert the CST screw into the nut driver. 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill drill mode and begin insertion.When the nut driver spins free on the mode and begin insertion.When the nut driver spins freely on the SWC screw,installation is complete.Stop and remove drill. CST screw,installation is complete.Stop and remove drill. 5.The SWC screw is ready to receive 114"318"or metric all thread rod 5.The concrete screw is ready to receive 114",318°112",or metric all or bolt stock. thread rod or bolt stock.(#14SW red nut driver used with 112"screw) Note:Use a 1200 maximum RPM drill for installation. Note:Use a 1200 maximum RPM drill for installation. Note:Do not install concrete screws while the drill unit is in impact mode— Note:Do not install concrete screws while the drill unit is in impact mode— doing so will destroy the pullout factor of the fastener doing so will destroy the pullout factor of the screw. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 3 To find a distdbutor near you,call 800-848-5611 SAMMYS° FOR WOOD SAMMYS' FOR WOOD - Vertical Application Application Product Features Not less than Wood Flooring 2"nominal width •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill. thickness(2-1/2") (depth or side Wood Joist of vertical member) •Saves time from traditional - - - - - methods. Double Sheetrock Ceiling •Reduces installation costs. Assembled in the U.S.A. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-dtilfing may be required for GST N 25-380.Tool available on page 11. View our installation videos! OUT& Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Gty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 L 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 #14 Black 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 Nut Driver v 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Part#8113910 tg 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 If w � oHS ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 SIDEWINDER@ FOR WOOD -Horizontal ApplicationApplication o Product„ 5 Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5'pipe •Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. •Assembled in the U.S.A. :r View our installation videos! O YOUTUk HORIZONTALApprovals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Shear(Ibs) Load(Ibs) Gty QtY . VIL 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 Q. 3/8" 8022925 SWG 25-380 318 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL HEAD Tm FOR WOOD Swivel Application Application Product Features r..•an c.*00°.,,,.10", •Eliminates distortion of threaded rod. ", •Accommodates up to 3'%"x 12 pitch roof. •Allows 17°deflection from vertical. ..a •Saves time from traditional methods. •Reduces installation costs. �rre� •*. Assembled in the U.S.A.Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case • Size Number .• City e #14 Black SWIVEL MOUNT Nut Driver 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#81139101 1903 Dim.Lumber 1500 33/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 May require pre-drilling;consult joist manufacturer. Dim.Lumber #14 SH Orange ••will not swivel until installed with black nut driver. • Nut Driver Part#8273910 To find.distributor near y• 800-848-5611 SAMMYS® FOR STEEL SAMMYS' FOR STEEL - Vertical Application Application Product Features •Made with Teks®self-drilling fasteners- no pre-drilling required. •Installs into steel range from ` 20 gauge—1/2"thicknesses. �' •Saves time from traditional methods. •Reduces installation costs. •Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. •A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance,the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. ,► •Assembled in the U.S.A. P�►�.O�►JL� � View our installation videos! MuTube Approvals Rod Part Model Screw Ultimate ILL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x V TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4'. 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 _ 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 0 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-112"TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 �} 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 i 0 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) #14 Black 3/8" 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 Nut Driver Y 0 3/8" 8046957 TEK 50 12-24 x 1-112"TEKS 5 3125 (3/16") 1500 1475 .250"-l/4" 1/2" 25 125 Part#8113910 446 (20 ga.) .::--•� 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 g70 (16 ga.) .188"-3/16" 1/4" 25 125 .. 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 s � oHS 00"I ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. ProductSIDEWINDERI FOR STEEL -Horizontal Application Application •Made with Teks°self-drilling fasteners-no pre-drilling required. NO •Installs into steel range from 20 gauge—1/2"thicknesses. }�� •A standard screwgun with a depth sensitive nosepiece should be used to install Teks.For optimal fastener performance,the screwgun should be a -- minimum of 6 amps and have an RPM range of 0-2500. Y0 •Saves time from traditional methods. J •Reduces installation costs. W •Quick to install using the Sammys Nut Driver with an View our W 18V cordless drill/driver. installation videos! •Asembled in the U.S.A. 0 YothbeApprovals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case y Size Number D- Qty Qty HORIZONTAL MOUNT 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 v 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8054957 SWDR 1-1/2* 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 3/8" 8056957 SWDR 516* 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL .Tm • - STEEL Application Application Product Features •Eliminates distortion of threaded rod in sloped roof applications. r •Accommodates 3-1/2 x 12 pitch. • •Installs into angled z-purlin;allows threaded rod to hang plumb. •Allows 17°deflection from vertical. •Asembled in the U.S.A. 1 View our installation videos! CYoubbe Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case Size Number •. Qty Qty SWIVEL MOUNT M #14Black " 81379 11TEK S 3 X 1" ( ) Nut 3/8 57 SH-DSTR 1* Driver TEK 3220 3/16" 1500 1475 .035" 3/16" 25 125 Nut Part#8113910 2368(1/2"steel Vertical) 3/8" 8268957 SH-TEK 50 12-24 x 1-5/8" 1306(45°off Vertical) 1500(Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281(3/16"HISS) 850(45°off Vertical) 2-1/2" 1585(3/16"HISS 45°off Vertical) *Does not comply with ROHS requirements/Includes retaining nut #14 SH Orange • Nut Driver Part#8273910 SA MMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel SAMMYX-PRESSOApplication ProductApplication •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin •No retaining nut required. � (22 ga.-1/8"). •Provides design flexibility. •Installs in seconds with Sammy X-Press It®Tool, saving time&installation costs. •Assembledin the U.S.A. •Use in applications where access to the back of View our the installed fastener is prohibited.is.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. Woubbe DescriptionApprovals Rod Part Model Size Number Pullout(lbs) Load(lbs) Thick Load(lbs) Thick Thick • QtY MOUNTVERTICAL Sammy 185(Luminaire) .027 NL 1/4" 8181922 XP 200 X-P ess 200 1146(22 ga) 250(Luminaire) .056" .125" 25 125 Metal Deck ■ 850(2%"Pipe) .027" 940 (2"Pipe) 029" X-Press 20 250 3/8" 8150922 XP 20 Sammy 1146(22 ga) 250(Luminaire)(Luminaire) .0.056"" 1475(4"Pipe) .104" .125" 25 125 Metal Deck 283(Conduit&Cable) .029" 1500(4"Pipe) .060" 3/8" 8153922 XP 35 X Pr ss 35 1783(16 ga) 250(Luminaire) .056" 4775((4"PI pe) .1104" .125" 25 125 Purlin 416(Conduit&Cable) .059" T Pre-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2%Pipe) 25 125 (Pre-Pour) X-Press 20 Post-Pour Range II LWC<_35 PCF(lbs/ft3) Metal Deck (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibs/ft') —J—�VVE Lr -�- Lr'� SAMMYX-PRESS SIDEWINDER'" - Horizontal Application Application Product •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. provide horizontal attachment in: 16 ga-3/16"steel-purlin,tubular steel. •No retaining nut required. •Installs in seconds with Sammy X-Press It®Tool, •Provides design flexibility. saving time&installation costs. •Assembled in U.S.A.of •Use in applications where access to the back of Canadian Steel the installed fastener is prohibited;ie.metal roof View our deck,tubular steel,or vapor barrier fabric. installation videos! 0 Youbbe DescriptionApprovals Rod Part Model Size NumberShear(Ibs) Load(lbs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT 1250(3%'Pipe) 3/8" 8293957 SWXP 35 Sidewinder 1798(16 ga) 80 (Luminaire) .059" .125" 25 125 Metal rlin in X-Press 35 416(Conduit&Cable) Pu � S ASSEMBLER U.S A. TM SAMMYX-PRESSA . . ProductApplication •The Sammy X-Press Swivel allows you •Less jobsite material needed. to hang plumb in extreme roof pitches: 89*in z-purlin •No retaining nut required. 45'in metal deck for 12/12 pitch � •Provides design flexibility. EREM •Installs in seconds with Sammy X-Press It®Tool, f)10' n 1 G saving time&installation costs. •Assembled in the U.S.A. V�p1�NT •Use in applications where access to the back of View our the installed fastener is prohibited.ie.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. MOW— O — DescriptionApprovals Rod Part Model Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty MOUNTSWIVEL 750(2"Pipe) Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) Metal Deck/ 3/8" 8294922 SXP 20 80 @ 45°(Luminaire) .029" 635(2"Pipe) .029" .125" 25 125 X-Press 20 829(45°Off Vert) 283 Vertical(Conduit&Cable) Pudin 11J 233 @ 45°(Conduit&Cable) 'W 1250(3-1/2"Pipe) 250 Vertical(Luminaire) ? 3/8" 8295922 SXP 35 Swivel 1675(16 ga Vert) 80 @ 90°(Luminaire) '059° '029" .125" 25 125(Luminaire) Metal Deck/ X-Press 35 1558(89°Off Vert) 500 Vertical(Conduit&Cable) 635(2"Pipe) Purlin 333 @ 89°(Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vert) Pudin 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) Metal Deck/ X-Press 3.5 1558(89°Off Vert) .060" .125" 25 125 Pudin • SAMMYX- - - © • • • Application Product ` •The Sammy X-Press expands to provide direct vertical attachment in: metal deck(22-16 gauge) y4 J t z-purlin(18-16 gauge) •Assembled in the U.S.A. View our installation videos! 0 Youbbe DescriptionPart Number Model 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64"Drill Bit 1 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. 1 1 • To find-distributor near y• 800-848-5611 SAMMYS° FOR CONCRETE SAMMYS@ FOR CONCRETE — Vertical Application Application Product Features •Easy two step process(Drill hole& *•4��'4 ,d o d v; �•4,'Q drive Sammys concrete anchor). ?" 'a r 4?" a •1W pre-drilled pilot hole required. . 7 ` .D `ad•`aJ�A�• :d `pd• •� •Concrete Installation Tool available for CC a one tool installation process. •Assembled in the U.S.A. -j .f••'ft••r ••r•' � j•• fir View our ... installation videos! 0YOUTUbe Size Number Descriptions Pullout(lbs)* Load(lbs)Approvals Rod Part Model Screw Ultimate I'M Test Box Case VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part#8113910 — #14SW Red 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 36-EFM 3/8" 8306957 CCST 516 5116-14 x 2-1/2" 857** 25 125 Part#8114910 For complete performance data see ICC Report ESR-3699 Tested in 3000 PSI concrete **Pullout strength for Cracked Concrete and Seismic Zones A-F ProductSIDEWINDEW FOR CONCRETE - Horizontal Application Application �' •Easy two step process(Drill hole&drive •4• U°• Sammys concrete anchor). � I I • C p '�' o'P Z •'/<"pre-drilled pilot hole required. •Concrete Installation Tool available for a one tool D., -p. • C installation process. d ri ol77`4; , a o � •Assembleded in the U.S.A. View our installation videos! OYNTUM Approvals Rod Part Model Screw Ultimate FM Test Box Case Size Number 1• Qty Qty HORIZONTAL MOUNT 0 3/8" 8061957 SWC 20 5/16 x 1-3/4" 2450 1475 25 125 O 369gEFM 3/8" 8307957 SW-CCST 516 5/16-14 x 2-1/2" 857** 25 125 #14SW Red Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Nut Driver Part#8114910 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.ASSEMBLED U.S.A. �S free.Installation n t onis then complete.rWarranty requires thecuse ltof the appropriate nut driver for installations.continue drilling until nut driver spins OZZHH'yo SAMMYS SWIVEL HEAD Tm FOR CONCRETE Swivel Application Application Product Features •Installs vertically and swivels up to 89°in wood& concrete structures. •:moo s..�:=.P' Eliminates distortion of threaded rod. •1/4"pre-drilled pilot hole required. •Concrete installation tool available for a one piece installation process. •Assembled in the U.S.A. Approvals Rod Part Model Screw Ultimate Box Case Size Number .• Qty Qty SWIVEL MOUNT 2537 in 3000 psi concrete 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1459 @ 45°off vertical in 3000 psi concrete 25 125 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete FM 3/8" 8308957 SH-CCST 516 5/16-14 x 2-1/2" 857** 25 125 Note:UL Listed for wood-see page 5 #14 SH Orange Nut Driver Part#8273910 *Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Uj CONCRETE I WOOD INSTALLATIONLLI Ct V Application Z 'CRotary Hammer Drill into concrete Hammer Drill into concrete (b) b (9) (d) (h) (gam (e) (h) -sepiao, (C) (c) (a) Part Number Description Each Qty • 8122910 Concrete Installation Kit(a) 1 Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 8114910 #14 SW Red Nut Driver(c) 1 8116910c #250 Bit(1/4")(d) 1 8117910 SIDS Bit(1/4")(e) 1 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 8098910 SL 250 Sleeve(h) 1 To find a distributor near you,call 800-848-5611 ACCESSORIES SAMMYS TOGGLE TM Application Installation Steps 1.Pre-drill a 5/8"hole with a regular drill or hole saw. 4N, 2.Insert SST screw into#14 black nut driver.With wing nut and washer on bolt,insert wing nut through surface,and begin J installation. 3.When bolt is secure and nut driver spins free,stop drill motor and remove. Pre-Cast Hollow Core 4.SST screw is now ready to receive 114",3/8",or Metric all Concrete thread rod or bolt stock. o. r D• e ty 'Size Part Number Model • 450 (Lath&Plaster)' 3/8" 8064925 SST 30 1/4 x 3" 404 (2 Layers 5/8 Rock) 25 125 #14 Black Nut Driver Part#8113910 PIPE Application ,r •Complies with NFPA 13 Code Changes. •Flashing for dry pendant sprinklers subject to 4-f�RTITE 51 AY �p TO extreme temperature changes. CODE s •One piece construction is easy to install. --- with a qui<har, •Pipe diameter markings ensure accurate fit. U ARM more efficient war HOLE to fl4sh your •EPDM temperature range of-65OF to+250°F. refri9crationifreaicy units. tresrtUlTEo FREEZER STRUCTURE t—Nn fif>fU�118 Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4003910 1 1/4"-2" 4-3/4" 3" 10 4004910 2 1-3/4"-3-1/4" 6-1/4" 4" 10 . 1. - 1 11. 611 11. oil SAMMYX-PRESS POLE TOOL • Application Product Features Speed your labor by 25% Work from the ground up It �w No scaffolding,ladders,or lifts v Perfect for working in tight spaces,through ceiling grid, --— and high vaulted ceilings For use installing Works with any Sammy X-Press product t Sammy X-Press anchors from the ground up! View our installation videos! p YouTube r Part Number Model Description Box Qty 1 XPKIT* XPKIT Sammy X-Press Pole Tool Kit 1 3/4"electdcal conduit needed for pole tool assembly • ji• SAMMYS �. POLE TOOL TIM Installation , Product Speed your labor by 25% 1 2 3 Insert •Work from the ground up adjust! here No scaffolding,ladders,or lifts Perfect for working in tight spaces,through ceiling grid, Adjust the Pole Tool to length. Load rod and Sammys into The socket will spin free and high vaulted ceilings The adjusting pin must be 18" Pole Tool. when the screw is completely below the base or the pin may installed.Pull down to remove •Works with any Vertical SAMMYS:Wood,Steel,or interfere with the rod. the Pole Tool. Concrete • Part Number Description Box Qty Pole 6'-18' 1 W W O 0 W V V Q • APPROVALS Part Numberr . ..• Mount UL Max ULTest UIL Min Wood FM Max FM Test FM Min Wood _ 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2' 8068925 GST20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-112' 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG25-380 3/8" Horizontal 3-1/2"-4"* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3"** 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45"Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1475 1-1/2" SAMMYS FOR STEEL-PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 318" 17'Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK50 3/8" Vertical 2-1/2" 850 70*Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89' 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE-PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC<_35 PCF(lbs/fC) Part Model .. Mount UL Load UL Min Steel SAMMYS Number Size Direction Rating(Ibs) Thickness 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 318" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8' Vertical 170 .027" 45' 80 .027" 8295922 SXP 35 3/8' Vertical 250 .060" 90* 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" Part Model Rod Mount UL Load UL Min.Steel Listed Application Number Size Direction Rating(Ibs) Thickness SAMMYS FOR CONDUIT, 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 1/4"or 3/8" Onto Vertical Rod UL Listed 4S16-Cable Hanger,Cat.No.C-Z2000 Plenum Rated, Complies w/NEC Standards GaugesSheet Steel Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber orjoist allowed by UL is 4" UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum pipe size in wood timber or'oisl allowed to UL is 3" SPECIAL NOTES • Engineering Note • In 1996,the anchors listed by UL were tested in plate steel that measured.188"and.118".Subsequent testing was done for z-purlin applications in May 1997 using(.037")or 20 gauge steel.Most recently in 2008,testing with the new Sammy X-Press®was completed using(.030")or 22 gauge steel metal deck. Sammys®Nut Drivers Special nut drivers were designed to be used with Sammys.When the appropriate nut drivers are used for installation,the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure. Steel Screws Due to variations in hardness of certain metals,it should be noted that our self-drilling screws for steel will experience different drill speeds.500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist.UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a composite joist.Penetration of the upright center web is permitted by some joist manufacturers.Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot hole 1/8"smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7132" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers,and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards.Check with your local(AHJ)Authority Having Jurisdiction to confirm application and usage. UL Listings/FM Approvals UL and FM reports are available at www.itwbuildex.com �uLD 5 O • 111B RAKER ALSO LISTED AS CONDUIT AN O CABLE HARD WARE ALSO USMB AS ANCHOR FOR LUMINAIRE B., Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats:.dwg,.dxf,and.igs. Assembled in the U.S.A. Products Contact Information As—bledUSA Technical Assistance:(800)848-5611 Option#6(x 3259) Customer Service:(800)848-5611 Option#1 • J Q Q. Q. Q 15 To find a distributor near you,call 800-848-5611 Angle Hose Valves 111S1S7r--0L FPPI° Description Angle hose valves feature all brass"construction with forged or cast bodies '' for rigidity and light weight. Typical uses are in rack assemblies or any other application which requires a listed fire hose valve. Available in rough brass or polished chrome finish with a red hand wheel. UL, ULc Listed, FM Approved. Rated 300psi Installation Specifications Install in accordance with customary installation practices. Use an approved thread sealant such as PipeFit°Thread Sealing Paste with PTFE on the male Material: Cast or Forged Brass Body threads to which the valve is being installed. Finish: DO NOT OVER TIGHTEN. Over tightening of the valve during installation Rough Brass Polished Chrome* to the male pipe threads may crack or deform the valve body. Only use tools suitable for the installation of this product. Do not use pipe wrench Threads: extenders to increase leverage on pipe wrenches. This may result in valve 2 1/2" FNPT x FNPT damage as well as personal injury. x MNST x MBCT x MQST x MONT x MPHX x MTEM x MCLV x MNYFD x MDET x MCF x MRCH 21/2" GRV x FNPT x MNST x MQST x MNYFD 2 1/2" FNPT x 3 MNST The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance 1 1/2" FNPT x FNPT and information purposes only.FPPI and its agents cannot assume liability or responsibility for results obtained in the x MNST use or misuse of its product by persons whose methods and qualifications are outside and beyond our control.It is the user's responsibility to determine the suitability of,methods of use,preparation prior to use,and appropriate installation `Contains lead.Not for use in for all products purchased from FPPI.It is the user's sole responsibility to observe and adapt such precautions as may water systems intended for human be advisable or necessary for the protection of personnel and property in the handling and use of any of our products. consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 +1 (760)599-1168 +1 (800)344-1822 +1 (800)344-3775 FAX C ul us FM APPROVED ©2017 Fire Protection Products,Inc. 37WL TATA TT U1111fill IT, CO® Worldwide www.tyco-fire.com Contacts Model DPV4 Dry Pipe Valve External Resetting General Description The TYCO Model DPV-1 Dry Pipe Valves are differential valves used to automatically control the flow of water into dry pipe fire protection sprinkler systems upon operation of one or more I automatic sprinklers. The DPV-1 also provides for actuation of fire alarms r: upon system operation. The Model DPV-1 features are as follows: • External reset. • 250 psi (17,2 bar) pressure rating. • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. • Ductile iron construction to ensure Available Sizes and End Connections a lightweight valve to minimize ship- ping cost. Nominal Valve Size • A variety of inlet and outlet End Connection 2-1/2 in. 3 in. 4 in. 6 in. connections. (DN65) (DN80) (DN100) (DN150) • Compact, Pre-Trimmed, and Semi- Flange x Flange N/A N/A • Assembled, easy to operate valve Flange x Groove N/A N/A • trim. Groove x Groove • • Simple reset procedure through the .=Available elimination of priming water. N/A=Not Available Dry pipe sprinkler systems are used in unheated warehouses, parking INOTRIM Dry Pipe Valve garages, store windows, attic The Model DPV-1 Dry Pipe Valves The TYCO Model DPV-1 Dry Pipe spaces, loading docks, and other described herein must be installed Valves shall be installed in the verti- areas exposed to freezing tempera- and maintained in compliance with cal orientation only (supply at bottom tures, where water filled pipe cannot this document, as well as with the flowing upward)and are rated for use at be utilized. When set for service, the applicable standards of the National a maximum service pressure of 250 psi dry pipe sprinkler system is pressur- Fire Protection Association, in addition (17,2 bar). Valve and trim dimensions ized with air (or nitrogen). The loss of to the standards of any other authori- are shown in Figure 6. pressure through an operated auto- ties having jurisdiction. Failure to do so Flanged connections are available and matic sprinkler in response to heat may impair the performance of these drilled per ANSI,ISO,AS,and JIS spec- from a fire permits the DPV-1 Dry devices. ifications (Ref. Table A). The grooved Pipe Valve to open and allow a flow of outlet connections, as applicable, are water into the sprinkler system piping. The owner is responsible for main- cut in accordance with standard groove Table B establishes the minimum taining their fire protection system specifications for steel pipe. They are required system air pressure that and devices in proper operating con- suitable for use with grooved end pipe includes a safety factor to help prevent dition. Contact the installing contrac- couplings that are listed or approved false operations that might occur due for or product manufacturer with any for fire protection system service. to water supply fluctuations. questions. Available combinations of inlet and outlet connections are described in Technical Data the Ordering Procedure section and in IMPORTANT the Available End Connection and Sizes Refer to Technical Data Sheet Approvals table on page 1. TFP2300 for warnings pertaining to UL and C-UL Listed regulatory and health information. FM Approved Trim port connections of valves having NYC Approved flanges drilled to ANSI,AS,or JIS spec- Page 1 of 20 OCTOBER 2018 TFP1020 TFP1020 Page 2 of 20 NO. DESCRIPTION QTY. REF 1 Valve Body.......1 NR 2 Air and Water Seat . .. .... .....1 NR 3 Handhole Cover...1 NR 4 Handhole Cover Gasket . .........1 (b) 0-11 5 1/2-13 UNC x 1" Hex Head Cap Screw: 2-1/2&3 Inch 12 Valves.. .........5 CH 6 4 Inch Valve ......6 CH ® 13 6 Clapper. .........1 (a) 7 Clapper Facing....1 (a)or(b) 7 RESET 8 Clapper Facing CLAPPER 14 PLUNGER Retaining Plate....1 (a) ASSEMBLY ��8 PARTS 9 2-1/2 and 3 Inch Valves: 15,18 1/4"x Long Shoulder � #10-32 Shoulder 9 Screw.. .........5 (a) 16 4 Inch Valve: 1/4-20 UNC x 1/2" Socket Head Cap 17 Screw.. .........7 (a) 10 Clapper Hinge Pin .. .. .. .......1 (a) 11 Reset Knob ......1 (c)or(d) 12 Reset Spring .....1 (c) 0 13 Reset Bushing ....1 (c) 14 Reset Bushing O-Ring.. .........1 (b),(c)or(e) 15 Reset Plunger O-Ring . .. .......1 (b)or(c) 16 Reset Plunger.....1 (c) 17 Reset Latch I Subassembly .....1 (c) 18 Dow Corning FS3452 FlouroGrease, 1.5ne 1 Grease,1.5 g .....1 (b)or(c) 4 NR:Not Replaceable / 3 CH:Common Hardware 2 \ ® / REPLACEMENT PARTS NO. DESCRIPTION P/N / ® Q (a) Clapper Assembly Includes Items 6-10: I 0 Q 2-1/2&3 Inch Valves. . 92-310-2-203 4 Inch Valve ........ . 92-310-2-403 ® (b) Repair Parts Kit 10 Includes Items 0 5 4,7, 14,15,&18: 2-1/2&3 Inch Valves. . 92-310-1-204 4 Inch Valve ........ . 92-310-1-404 (c) Reset Plunger Parts Kit Includes Items 11-18. . 92-310-1-405 (d) Reset Knob, Item 11.. . 92-310-1-406 (e) Reset Plunger O-Ring,Item 15 ..... . 92-310-1-407 FIGURE 1 -PART 1 OF MODEL DPV-1 DRY PIPE VALVE 2-1/2,3,AND 4 INCH(DN65,DN80, DN100)ASSEMBLIES TFP1020 Page 3 of 20 NO. DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY. REP.PART 1 Valve Body.. ... ..1 NR 5 Socket Head Cap 8 Hex Head Cap Screw 2 Air and Water Screw 5/8-11 UNC x 1". ..6 CH Seat . .. .... ... ..1 NR 3/8-16 UNC x 1". . .8 NR 9 Clapper. .. .. ... ..1 (a) 3 Water Seal 6 Handhole Cover. ..1 NR 10 Clapper Facing.. ..1 (a)or(b) O-Ring . .........1 NR 7 Handhole Cover 11 Clapper Facing 4 Air Seal O-Ring....1 NR Gasket . .. .. ... ..1 (b) Retaining Plate....1 (a) 12 Socket Head Cap Screw 1/4-20 UNC x 1/2" .9 (a) 0-14 13 Clapper Hinge Pin..1 (a) 14 Reset Knob ......1 (c)or(d) / 15 Reset Spring .....1 (c) 15 16 Reset Bushing ....1 (c) / 17 Reset Bushing 16 O-Ring.. .........1 (b),(c)or(e) 10 1 1 18 Reset Plunger CLAPPER RESET O-Ring1 b or c ASSEMBLY 17 PLUNGER 19 Reset Plunger.....1 (c) j—1 PARTS 20 Reset Latch 18,21 Subassembly .....1 (c) 12 21 Dow Corning FS3452 Flourosilicone 19 Grease,1.5 g ... ..1 (b)or(c) 0 0 NR:Not Replaceable 20 CH:Common Hardware CD 0 \ REPLACEMENT PARTS ° NO. DESCRIPTION P/N / (a) Clapper Assembly Includes Items 9-13.. . 92-310-2-603 (b) Repair Parts Kit 2 0 Includes Items 7, 10,17, 18,21 . . . .. . 92-310-1-604 (c) Reset Plunger Parts Kit CD Includes Items 14-21 . . 92-310-1-405 l\ (d) Reset Knob, Item 14.. . 92-310-1-406 O O (e) Reset Plunger IO-Ring,Item 18 ..... . 92-310-1-407 4 / 1 7 00 3 5 o ® o 13 0 0 � o o ' 0 FIGURE 1 -PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVE 6 INCH(DN150)ASSEMBLY TFP1020 Page 4 of 20 Flange Drilling Specification Nominal Dimensions in Inches and(mm) Dim.A Nominal Bolt Circle Valve ANSI B16.11 ISO 7005-2 JIS B 2210 AS 2129 Diameter Size (Class 125) (PN16)2 (10K) (Table E) C"7 Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. City. o Dim. B A B N A B N A B N A B N ���Bolt Hole 4 in. 7.50 0.75 87.09 0.75 86.89 0.59 8 7.00 0.71 8 Diameter (DN100) (190,5) (19,0) (180,0) (19,0) (175,0) (15,0) (178,0) (18,0) � 6 in. 9.50 0.88 9.45 0.91 9.45 0.75 9.25 0.87 Qty.N (DN150) (241,3) (22,2) 8 (240,0) (23,0) 8 (240,0) (19,0) 8 (235,0) (22,0) 8 Number of Bolt Holes 1. Drilling same as ANSI 316.5(Class 150)and ANSI 1316.42(Class 150). 2. Drilling same as BS 4504 Section 3.2(PN16)and DIN 2532(PN16). TABLE A SELECTION OF FLANGE DRILLING SPECIFICATIONS ifications are NPT threaded per ANSI Pre-trimmed valve assemblies also 4 in.(DN100)FxF....................77 lb(36 kg) Standard B1.20.1. Trim port connec- include the following equipment: 6 in.(DN150)GxG...................95 lb(44 kg) tions of valves having flanges drilled . Model BFV-300 butterfly valve 6 in. DN150 FxG..................108 lb 50 k to ISO are available either threaded ( ) ( g) per ISO 7-1 or NPT threaded per ANSI • Figure 577 grooved coupling 6 in.(DN150)FxF...................121 lb(56 kg) Standard 131.20.1. Valves with NPT . PS10-2 waterflow alarm switch threaded ports will readily accept the Air Supply trim arrangements shown in Parts 2 • PS40-2 low air pressure alarm switch Table B shows the system air pres- and 3 of Figures 3, 4, and 5. Order the above equipment sepa- sure requirements as a function of the ro- Model DPV-1 Valve assemblies are rately when ordering trim packages water supply pressure.The air(or stem shown in Figure 1.The Body and Hand- separately. is re pressure in the sprinkler system hole Cover are ductile iron.The Hand- is recommended to be automatically hole Cover Gasket is neoprene, and Note: When the system pressure is maintained by using one of the follow- hole greater than 175 psi(12,1 bar),provision ing pressure maintenance devices, as the Clapper Facing is EPDM. The Air/ shall be made to replace the standard appropriate: Water Seat Ring is brass, the Clapper order 300 psi(20,7 bar)Water Pressure . Model AMD-1 Air Maintenance is bronze or aluminum bronze,and both gauge with a separately ordered 600 the Clapper Retaining Plate and Latch psi(41,4 bar) Water Pressure Gauge. Device(pressure reducing type) are bronze.The Hinge Pin is aluminum • Model AMD-2 Air Maintenance bronze,and the fasteners for the Hand- Weights Device(compressor control type) hole Cover are carbon steel. The following are the nominal weights for Pre-Trimmed Valve Assemblies, • Model AMD-3 Nitrogen Maintenance Valve Trim Semi-Assembled Trim, and DPV-1 Device(high pressure reducing type) Installation dimensions are provided Valves without trim. in Figure 6, and Valve Trim and Pre- The Pressure Relief Valve provided with Trimmed Valve Assemblies are shown Pre-Trimmed DPV-1 Valve the valve trim is factory set to relieve in Figures 3, 4, and 5. Assemblies: at a pressure of approximately 45 psi (3,1 bar). If the normal system air pres- The valve trim,ordered separately or as 2-1/2 in.(DN65)GxG..............87 lb(40 kg) sure is less than or exceeds 40 psi(2,8 a pre-trimmed valve assembly, forms 3 in.(DN80)GxG.....................90 lb(42 kg) bar), then the pressure Relief Valve t be reset to relieve at a pressure approvals of the DPV-1 Valve and is 4 in.(DN100)GxG.................121 lb(56 kg) that is in accordance with the authority necessary for the proper operation of 4 in.(DN100)FxG..................135 lb(64 kg) having jurisdiction. the DPV-1 Valve. 4 in.(DN100)FxF..................145 lb(69 kg) Quick Opening Device Trim packages or pre-trimmed valve The Model DPV-1 Dry Pipe Valve may assemblies include the following 6 in.(DN150)GxG.................175 lb(81 kg) optionally be equipped with an elec- equipment: 6 in.(DN150)FxG..................195 lb(90 kg) tronic or mechanical dry pipe valve • Water Supply Pressure Gauge accelerator. Select the VIZOR Elec- 6 in.(DN150)FxF...................208 lb(96 kg) tronic Dry Pipe Valve Accelerator • System Air Pressure Gauge Standard Galvanized (4 and 6 in. sizes only) described in • Air Supply Connections Semi-Assembled DPV-1 Trim: Technical Data Sheet TFP1105 or the Model ACC-1 Mechanical Dry Pipe • Main Drain Valve 2-1/2 in.(DN65)........................23 lb(11 kg) Valve Accelerator (2-1/2 through 6 in. • Low Body Drain Valve 3 in.(DN80)..............................23 lb(11 kg) sizes) described in Technical Data • Alarm Test Valve 4 in.(DN100)............................30 lb(14 kg) Sheet TFP1112. • Automatic Drain Valve 6 in. DN150 30 lb 14 k The VIZOR or the ACC-1 is used to ( ) ( g) reduce the time to valve actuation fol- • Drip Funnel DPV-1 Valve(Without Trim): lowing the operation of one or more • Connections For Optional Quick 2-1/2 in.(DN65)GxG...............37 lb(17 kg) automatic sprinklers. In some cases the use of a quick opening device Opening Device(Accelerator) 3 in.(DN80)GxG......................38 Ib(18 kg) such as the VIZOR or the ACC-1 may 4 in.(DN100)GxG...................57 lb(26 kg) be required to meet the requirements of the National Fire Protection Association 4 in.(DN100)FxG....................67 1b(31 kg) to meet water delivery times. TFP1020 Page 5 of 20 Maximum System Air FLOW RATE IN LITRES PER MINUTE(LPM) Water Supply Pressure (1 GPM=3.785 LPM) Pressure Range 500 700 1000 2000 3000 5000 10000 psi psi 9.0 � 0,60 20 10 a 7.0 0,50 60 15-23 = 80 20-28 0,40 z 5.0 100 25-33 Lu 4.0 0 0,30 Z� 145 36-43 O 3'0 Q 0,20 m 165 40-48 � 185 45-53 a 2.0 O Oa Q 205 50-58 0 ^� 0,10 tr m Lo 225 55-63 Z =�O� Q 0,08 LLJ°' 250 1 60-68 a 1.0 V� O= D o TABLE B z G� 0,06 co o 2 D C 0,05 w n SYSTEM AIR PRESSURE a 0.7 N = � REQUIREMENTS � ^� (0 0,04 a a p 0.5 ti z w 0,03 Operation r[ 0.4 0 0 0.3 0,02 Z The TYCO Model DPV-1 Dry Pipe Valve a is a differential type valve that utilizes a a 0.2 substantially lower system(air or nitro- Q gen) pressure than the supply (water) 0,01 pressure, to maintain the set position o shown in Figure 2A. The differential Z 0.1 nature of the DPV-1 is based on the 100 200 300 500 700 1000 2000 3000 area difference between the air seat FLOW RATE IN GALLONS PER MINUTE(GPM) and the water seat in combination with The approximate friction losses,based on the Hazen and Williams formula and expressed in equivalent length of the ratio of the radial difference from Schedule 40 pipe with C=100 and flowing at typical flow rates,are as follows: the Hinge Pin to the center of the Water 2-1/2 in.valve at 250 GPM flow=2.2 ft 4 in.valve at 600 GPM flow=8.9 ft Seat and the Hinge Pin to the center of 3 in.valve at 350 GPM flow=4.9 ft 6 in.valve at 1500 GPM flow=22.0 ft the Air Seat.The difference is such that GRAPH A 1 psi (0,07 bar) of system air pressure MODEL DPV-1 DRY PIPE VALVES can hold approximately 5.5 psi (0,38 1 NOMINAL PRESSURE LOSS VS. FLOW bar)of water supply pressure. Table B establishes the minimum sure of 100 psi (6,9 bar). It is for this After a valve actuation and upon sub- required system air pressure that reason that the plunger of the Auto- sequent closing of a system main includes a safety factor to help prevent matic Drain Valve must be depressed control valve to stop water flow, the false operations that occur due to water during several of the resetting steps, Clapper Assembly will latch open as supply fluctuations. as well as during inspections, making shown in Figure 3D. Latching open of certain that the Automatic Drain Valve the DPV-1 will permit complete drain- The Intermediate Chamber of the is open. ing of the system (including any loose DPV-1 is formed by the area between scale)through the main drain port. the Air Seat and Water Seat as shown in When one or more automatic sprin- Figure 213. The Intermediate Chamber klers operate in response to a fire, During the valve resetting procedure normally remains at atmospheric pres- air pressure within the system piping and after the system is completely sure through the Alarm Port connection is relieved through the open sprin- drained,the external reset knob can be and the valve trim to the normally open klers. When the air pressure is suf- easily depressed to externally unlatch Automatic Drain Valve (Fig. 3, 4, or ficiently reduced, the water pressure the Clapper Assembly, as shown 5). Having the Intermediate Chamber, overcomes the differential holding in Figure 2E. As such, the Clapper Figure 26, open to atmosphere is criti- the Clapper Assembly closed and the Assembly is returned to its normal set cal to the DPV-1 Valve remaining set, Clapper Assembly swings clear of the position to facilitate setting of the dry otherwise the full resulting pressure of water seat, as shown in Figure 2C, pipe sprinkler system,without having to the system air pressure on top of the This action permits water flow into the remove the Handhole Cover. Clapper Assembly cannot be realized. system piping and subsequently to be discharged from any open sprinklers. For example, and assuming a water Also,with the Clapper Assembly open, supply pressure of 100 psi (6,9 bar), if the intermediate chamber is pressur- the system air pressure is 25 psi (1,7 ized and water flows through the alarm bar) and there was 15 psi (1,0 bar) port (Ref. Figure 26) at the rear of the pressure trapped in the Intermediate DPV-1 Valve to actuate system water Chamber,the resulting pressure across flow alarms. The flow from the alarm the top of the Clapper would only be 10 port is also sufficient to close the oth- psi (0,7 bar). This pressure would be erwise normally open Automatic Drain insufficient to hold the Clapper Assem- Valve in the valve trim. bly closed against a water supply pres- TFP1O2O Page 6 of 20 Installation be equipped with a Dry Pipe Valve however, it must be reset to relieve Accelerator, refer to the Technical at a pressure which is in accordance General Instructions Data Sheet TFP1105 for the VIZOR with the requirements of the author- Proper operation of the Model DPV-1 Electronic Dry Pipe Valve Accel- ity having jurisdiction. Dry Pipe Valve depends upon its trim erator or TFP1112 for the Model To reset the Pressure Relief Valve, being installed in accordance with the ACC-1 Mechanical Dry Pipe Valve first loosen the jam nut and then instructions given in this Technical Data Accelerator. adjust the cap accordingly — Sheet. Failure to follow the appropriate • Care must be taken to make sure that clockwise for a higher pressure trim diagram may prevent the DPV-1 check valves,strainers,globe valves, setting or counter-clockwise for a Valve from functioning properly, as etc.are installed with the flow arrows lower pressure setting.After veri- well as void listings,approvals,and the in the proper direction. fying the desired pressure setting, manufacturer warranties. tighten the jam nut. • Drain tubing to the drip funnel must . Installation of an Air Maintenance Failure to latch open the Clapper be installed with smooth bends that Device,Installation described in the MaintTechnienance prior to a system hydro- will not restrict flow. cal Data Section, is recommended. static test may result in damage to the . The main drain and drip funnel drain Clapper Assembly. may be interconnected provided a • An Inspector's Test Connection as The DPV-1 Valve must be installed in a check valve is located at least 12 in. required By NFPA 13 must be pro- readily visible and accessible location. (300 mm)below the drip funnel.The vided on the system piping at the Low Body Drain Valve(Figure 3,4,or most remote location from the Model The DPV-1 Valve and associated trim DPV-1 Valve. must be maintained at a minimum tem- 5) may be piped so as to discharge must ure of 40°F maintained at into the Drip Funnel or to a separate Conduit and electrical connections peradrain. are to be made in accordance with Heat tracing of the DPV-1 Valve or its Suitable provision must be made the requirements of the author- associated trim is not permitted. Heat for disposal of drain water. Drainage ity having jurisdiction and/or the tracing can result in the formation of water must be directed such that it National Electric Code. hardened mineral deposits that are will not cause accidental damage to Before a system hydrostatic test is capable of preventing proper operation. property or danger to persons. performed in accordance with NFPA The Model DPV-1 Dry Pipe Valve is to 13 system acceptance test require- be installed in accordance with the fol- Unused pressure alarm switch and/ ments, the Clapper Assembly is to lowing criteria: or water motor alarm connections be manually latched open (Ref. Fig- must be plugged. ure 2D); the Automatic Drain Valve • All nipples,fittings,and devices must The Pressure Relief Valve provided (Figure 3,4,or 5)is to be temporarily be clean and free of scale and burrs with the Valve Trim is factory set to replaced with a 1/2 in. NPT plug,the before installation. Use pipe thread relieve at a pressure of approximately 3/32 in. Vent Fitting (Item 13, Figure sealant sparingly on male pipe 45 psi (3,1 bar), which can typically 3; Item 15, Figure 4; or Item 15, Fig- threads only. be used for a maximum normal sys- ure 5) is to be temporarily replaced • The DPV-1 Valve must be trimmed tem air pressure of 40 psi (2,8 bar). with a 1/4 in. NPT plug, and the in accordance with Figures 3, 4, or The Pressure Relief Valve may be Handhole Cover Bolts are to be tight- 5, as applicable. If the DPV-1 is to reset to a lower or higher pressure; ened using a cross-draw sequence. TFP1O2O Page 7 of 20 Valve Setting Step 5.As necessary,replace all sprin- to the Care and Maintenance section klers that have operated. Replacement under Automatic Drain Valve Inspection Procedure sprinklers must be of the same type to determine/correct the cause of the and temperature rating as those which leakage problem. Steps 1 through 11 are to be performed have operated. Step 10. Partially open the Main when initially setting the Model DPV-1 Control Valve. Slowly close the Main Dry Pipe Valve;after an operational test MUM Drain Valve as soon as water dis- of the fire protection system; or, after In order to prevent the possibility of charges from the drain connection. system operation due to a fire. a subsequent operation of an over- Depress the plunger on the Automatic NOTES:If the DPV-1 is equipped with heated solder type sprinkler,any solder Drain Valve to make sure that it is open a Dry Pipe Valve Accelerator, refer to type sprinklers which were possibly and that there is no water discharging. its resetting instructions before reset- exposed to a temperature greater than The absence of water discharging from ting the DPV-1.Refer to TFP1105 for the their maximum rated ambient must be the Automatic Drain Valve is an indica- VIZOR or TFP1112 for the ACC-1. replaced. tion of a properly set water seat within Based on the instructions provided, Step 6. Push down on the Reset Knob the DPV-1 Valve. If water is discharg- reset the Accelerator at the appropriate (Figure 2E)to allow the Clapper Assem- ing, refer to the Care and Maintenance time during the resetting of the DPV-1. bly to re-seat. section under the Automatic Drain Step 7. Pressurize the system with air Valve Inspection to determine/correct Unless otherwise noted,refer to Figure 3, 4, or 5 to identify functional trim (or nitrogen) to 10 psi (0,7 bar), and the cause of the leakage problem. components. then individually open all auxiliary drain If there are no leaks,the DPV-1 Valve is valves in the system piping to drain ready to be placed in service and the Step 1. Close the Main Control Valve, any remaining water in trapped sec- Main Control Valve must then be fully and close the Air Supply Control Valve. tions. Close each drain valve as soon opened. If the DPV-1 is equipped with a Dry as water ceases to discharge. Note: After setting a fire protection Pipe Valve Accelerator, remove the Dry Pipe Valve Accelerator from service in Also partially open the Low Body Drain system, notify the proper authorities accordance with its Technical Data Valve to assure that the riser is com- and advise those responsible for moni- S heet(Refer to TFP1105 for the VIZOR pletely drained. Close the Low Body toring proprietary and/or central station or TFP1112 for the ACC-1). Drain Valve as soon as water ceases alarms. Step 2.Open the Main Drain Valve and to discharge. Step 11. Once a week after a valve is all auxiliary drains in the system.Close Step 8. Refer to Table B and then reset following an operational test or the auxiliary drain valves after water restore the system to the normal system operation,the Low Body Drain ceases to discharge. Leave the Main system air pressure as necessary to Valve (and any low point drain valves) Drain Valve open. hold the DPV-1 Valve closed. should be partially opened (and then Step 9. Depress the plunger on the subsequently closed) to relieve drain- Step Depress the plunger the Automatic Drain Valve to make sure back water. Continue this procedure drain- Automatic tic Drain Valve to verify that it is until drain-back water is no longer it is open and that there is no air open and that the DPV-1 Valve is com-pletely drained. discharging. present. Step 4. Open the Optional Alarm The absence of air discharging from Control Valve, as applicable, if it was the Automatic Drain Valve is an indica- closed to silence local alarms. tion of a properly set air seat within the DPV-1 Valve. If air is discharging, refer TFP1020 Page 8 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM itCLAPPER CLAPPER 1" NPT ASSEMBLY ASSEMBLY AIR SUPPLY IN SET FULLY OPEN \ PORT POSITION CLAPPER LATCH PIVOTS TO ALLOW 1WATERT "o CLAPPER ASSEMBLY L ° SUPPLY �, TO FULLY OPEN PR ESSURE -T-T- 3/4" NPT ALARM - - &ALARM i�Y PORT OPEN TO TEST PORT ATMOSPHERE VALARM PORT WATERFLOW CLAPPER TO ALARM ASSEMBLY FROM FROM WATER SUPPLY AIR WATER SUPPLY SEAT FIGURE 2A FIGURE 2C SET POSITION WATER OPERATED POSITION SEAT I � ALARM \ PORT DRAIN FROM DRAIN FROM SYSTEM SYSTEM VALVE INTERMEDIATE COMPLETE WATERWAY CHAMBER PUSH HERE It FIGURE 2B TO RESET SET POSITION VALVE INTERMEDIATE RESET CLAPPER CHAMBER KNOB ASSEMBLY - - LATCHED RESET OPEN ASSEMBLY CLAPPER _ LATCH o PIVOTS TO r o CLAPPER UNLATCH ' LATCH CLAPPER ASSEMBLY MAIN DRAIN PORT: 3/4" NPT 1-1/4" NPT`(2-1/2 INCH CLAPPER LOW BODY &3 INCH VALVES) ASSEMBLY DRAIN 2" NPT(4 INCH VALVE) RESEATED PORT WATER SUPPLY DN40 FOR VALVES WITH WATER SUPPLY SHUT OFF ISO THREADED PORTS SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVES 2-112, 3,AND 4 INCH(DN65, DN80,AND DN100) SET AND OPEN POSITIONS TFP1020 Page 9 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM CLAPPER t ASSEMBLY t FULLY OPEN 1" NPT CLAPPER LATCH AIR SUPPLY PIVOTS TO ALLOW PORT CLAPPER ASSEMBLY TO FULLY OPEN 3/4" NPT ALARM PORT OPEN TO ° CLAPPER ATMOSPHERE ASSEMBLY f, IN SET POSITION 1/2" NPT WATER SUPPLY m PRESSURE /— &ALARM TEST PORT ALARM PORT WATERFLOW CLAPPER TO ALARM ASSEMBLY AIR FROM SEAT FROM WATER SUPPLY WATER SUPPLY FIGURE 2A ALARM FIGURE 2C SET POSITION WATER PORT OPERATED POSITION SEAT m I DRAIN FROM DRAIN FROM SYSTEM SYSTEM INTERMEDIATE VALVE COMPLETE CHAMBER WATERWAYIt PUSH HERE FIGURE 2B SET POSITION TO RESET INTERMEDIATE VALVE CLAPPER CHAMBER RESET ASSEMBLY KNOB LATCHED OPEN - - RESET ASSEMBLY 3/4" NPT CLAPPER LOW BODY ° LATCH ` ° DRAIN PORT PIVOTS TO UNLATCH ' �- CLAPPER i i ASSEMBLY 2" NPT CLAPPER MAIN DRAIN LATCH PORT CLAPPER ASSEMBLY RESEATED WATER SUPPLY WATER SUPPLY SHUT OFF SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVES 6INCH(DN150) SET AND OPEN POSITIONS TFP1020 Page 10 of 20 NOTES: 1. SEE FIGURE 3 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. / SWITCH SYSTEM AIR SUPPLY 1 INCH NPT SYSTEM CONTROL VALVE CONNECTION AIR SUPPLY / (NORMALLY FOR LOCAL PRESSURE OPEN) SPRINKLER GAUGE �I 2-1/2 INCH(DN65) ��/A WATERFLOW 1/2 INCH NPT / or INCH(DN80) PRESSURE CONNECTION MODEL DPV-1 ALARM FOR SYSTEM DRY PIPE VALVE / SWITCH AIR SUPPLY (GxG ONLY) GROOVED MAIN COUPLING TEST VALVE e® DRAIN VALVE (NORMALLY ® (NORMALLY 1/2 INCH NPT CLOSED) CLOSED) CONNECTION SYSTEM 3/4 IN NPT \ SYSTEM FOR OPTIONAL WATER CONNECTION SHUT-OFF SUPPLY 1-1/4 INCH NPT ACCELERATOR PRESSURE TO DRAIN VALVE CONNECTION GAUGE LOW BODY (NORMALLY TO DRAIN AUTOMATIC DRAIN VALVE OPEN) DRAIN VALVE (NORMALLY 1-1/4 INCH NPT CLOSED) CONNECTION DRIP TO DRAIN FUNNEL FIGURE 3-PART 1 OF 3 2-112 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY AIR SUPPLY 1/2 INCH NPT 1/2 INCH NPT NOTES: CONTROL VALVE CONNECTION CONNECTION 1. INSTALL TRIM ASSEMBLIES IN (NORMALLY OPEN) FOR OPTIONAL FOR OPTIONAL ALPHABETICAL ORDER. ACCELERATOR AIR PRESSURE AUTOMATIC SWITCH 2. SEE FIGURE 2 FOR VALVE PORT 1/2 INCH NPT I DRAIN VALVE IDENTIFICATION. CONNECTION 3. ROUTE 1/4"TUBING TO DRIP FOR SYSTEM AIR SUPPLY H FUNNEL. \e = SYSTEM AIR SUPPLY MAIN 1/2 INCH NPT G D PRESSURE GAUGE A DRAIN VALVE CONNECTION (NORMALLY FOR WATERFLOW \ E \ CLOSED) PRESSURE ALARM SWITCH 1-1/4 INCH NPT DRIP CONNECTION FUNNEL TO DRAIN 1-1/4 INCH NPT \ CONNECTION 2-1/2 INCH(DN65) TO DRAIN 1 INCH NPT C or 3 INCH(DN80) CONNECTION MODEL DPV-1 FOR LOCAL DRY PIPE VALVE SPRINKLER (GxG ONLY) ALARM / F B/ LOW BODY TEST VALVE � DRAIN VALVE (NORMALLY SYSTEM (NORMALLY CLOSED) WATER SUPPLY 3/4 INCH NPT CLOSED) PRESSURE CONNECTION GAUGE TO DRAIN FIGURE 3-PART 2 OF 3 2-112 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 11 of 20 NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N 1 250 psi/1750 kPa 13 3/32"Vent 28 1"x 1"x 1/2" Air Pressure Fitting .. .. .. ... ..1 92-032-1-002 Reducing Tee ... ..1 CH Gauge.. .. .. ... ..1 92-343-1-012 14 1/4"Tube, 29 Not Used 2 300 psi/2000 kPa 18" Long....... ..1 CH PIPE NIPPLES: Water Pressure 15 1/4" Plug....... ..2 CH 30 1/4"x 3" ....... ..2 CH Gauge.. .. .. ... ..1 92-343-1-005 16 1/2" Plug....... ..2 CH 31 1/2"x Close .... ..4 CH 3 1/4"Gauge Test 17 1" Plug . .........1 CH 32 1/2"x 1-1/2".... ..8 CH Valve. .. .. .. ... ..2 46-005-1-002 18 1/2" Union. .......1 CH 33 1/2"x 2" ....... ..1 CH 4 Model AD-1 19 1/2"x 1/4" Reducing 34 1/2"x 4-1/2".... ..1 CH Automatic Bushing .........1 CH 35 1/2"x 6" ....... ..1 CH Drain Valve .. ... ..1 52-793-2-004 20 1/2"90'Elbow....3 CH 36 3/4"x Close .... ..1 CH 5 1/4" Pressure 21 3/4"90'Elbow....1 CH 37 3/4"x 1-1/2".... ..1 CH Relief Valve.. ... ..1 92-343-1-020 22 1-1/4"90'Elbow...1 CH 38 3/4"x 2-1/2".... ..1 CH 6 1/2" Ball Valve .. ..2 46-050-1-004 23 1/2"Cross........2 CH 39 1"x Close...... ..1 CH 7 3/4"Angle Valve. ..1 46-048-1-005 24 1/2"x 1/2"x 1/4" 40 1-1/4"x Close .. ..1 CH 8 1-1/4"Angle Valve .1 46-048-1-007 Reducing Tee .....1 CH 41 1-1/4"x 4"...... ..1 CH 9 1/2"Swing 25 1/2"Tee .........1 CH COMPONENTS INCLUDED ONLY IN Check Valve .... ..2 46-049-1-004 26 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 10 Drip Funnel Reducing Tee .....2 CH Connector... ... ..1 92-211-1-005 27 1/2"x 1/2"x 3/4" 42 Model BFV-300 11 Drip Funnel Reducing Tee .....1 CH Butterfly Valve, Bracket. .... ... ..1 92-211-1-003 2-1/2"(DN65).....1 59300GO25W 12 Drip Funnel.. ... ..1 92-343-1-007 3"(DN80) ........1 59300GO30W 45 43 Figure 577 Coupling, 2-1/2"(DN65).....1 57725ACP \/ 16 3"(DN80) ...... ..1 57730ACP 44 Waterflow Pressure 20 1 Alarm Switch, Model PS10-2... ..1 25710 9 19 45 Low Air Pressure 32 30 Alarm Switch, 5 32 6 32 23 Model PS40-2... ..1 25730 32 24 20 17 32 15 ® 34 39 3 44 33 28 2-1/2 INCH(DN65) g 16 4 or 3 INCH(DN80) MODEL DPV-1 25 31 27 DRY PIPE VALVE (GxG ONLY) 31 LOCATION 32 23 FOR OPTIONAL 10 36 41 8 18 ELECTRICALLY SUPERVISED 32 N.O.ALARM 20 1 22 31 40 CONTROL 11 VALVE 26 13 12 37 NOTES: 1 (GREEN 14 43 1. SEE FIGURE 2 FOR VALVE TINS 21 PORT IDENTIFICATION. 38 7 42 2. ROUTE 114"TUBING,ITEM 14, 31 TO DRIP FUNNEL,ITEM 12. 6 3. ALL FITTINGS AND NIPPLES 32 35 o ARE GALVANIZED. 26 2 4. CH:COMMON HARDWARE 30 5. ITEMS 42-45 INCLUDED 3 ONLY IN PRE-TRIMMED VALVE ASSEMBLIES AS APPLICABLE;OTHERWISE SEPARATELY ORDERED. FIGURE 3-PART 3 OF 3 2-1 12 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 12 of 20 1. SEE FIGURE 4 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM / AIR SUPPLY 1/2 INCH NPT SYSTEM 4 INCH(DN100) CONTROL VALVE CONNECTION AIR SUPPLY MODEL VALVE (NORMALLY \/ ® FOR SYSTEM PRESSURE DRY PIPE VALVE OPEN) AIR SUPPLY GAUGE (FxG SHOWN) 3/4 INCH NPT J 1 INCH NPT CONNECTION FLANGE ADAPTER FOR WATER CONNECTION OR GROOVED FOR LOCAL COUPLING MOTOR ALARM SPRINKLER MAIN WATERFLOW C�3/4 INCH NPT � � DRAIN VALVE o PRESSURE CONNECTION (NORMALLY ALARM TO DRAIN / CLOSED) 1/2 INCH NPT SWITCH CONNECTION ALARM / FOR OPTIONAL TEST VALVE \ SYSTEM 2 INCH NPT ACCELERATOR (NORMALLY LOW BODY CONNECTION CLOSED) DRAIN VALVE SYSTEM SHUT-OFF TO DRAIN AUTOMATIC WATER VALVE (NORMALLY SUPPLY (NORMALLY DRAIN VALVE CLOSED) PRESSURE OPEN) 1-1/4 INCH NPT GAUGE CONNECTION DRIP TO DRAIN FUNNEL FIGURE 4-PART 1 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT AIR SUPPLY CONNECTION CONTROL VALVE FOR OPTIONAL (NORMALLY ACCELERATOR OPEN) 1/2 INCH NPT MAIN CONNECTION SYSTEM DRAIN VALVE 0 1/2 INCH NPT AUTOMATIC AIR SUPPLY NORMALLY CONNECTION DRAIN VALVE FOR OPTIONAL PRESSURE AIR PRESSURE CLOSED) FOR WATERFLOW \ SWITCH GAUGE SLOPE PRESSURE ALARM DOWN SWITCH \ D I 3/4 INCH NPT CONNECTION FOR WATER A MOTOR ALARM � \ � 1/2 INCH NPT �/ 2 INCH NPT CONNECTION CONNECTION FOR SYSTEM ~ TO DRAIN � I AIR SUPPLY C 0 4 INCH(DN100) ALARM �' �o_ — C) MODEL DPV-1 TEST VALVE / DRY PIPE VALVE (NORMALLY (FxG SHOWN) CLOSED) 3/4 1 INCH NPT NOTES: B CONNECTION 1. INSTALL TRIM ASSEMBLIES IN SYSTEM INCH NPT FOR LOCAL ALPHABETICAL ORDER. ONNECTON CI WATER SUPPLY SPRINKLER PRESSURE TO DRAIN 2. SEE FIGURE 2 FOR VALVE PORT GAUGE LOW BODY IDENTIFICATION. DRIP DRAIN VALVE 3. ROUTE 1/4"TUBING TO DRIP FUNNEL. FUNNEL 1-1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE TO DRAIN SUFFICIENT LOW BODY DRAINAGE. FIGURE 4-PART 2 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 13 of 20 l NOTES: 47 16 48 1. SEE FIGURE 2 FOR VALVE 28 18 PORT IDENTIFICATION. 5 6 2. ROUTE TUBING, ITEM 16, FUNNEL, 0 15 27 TO DRIP FUNNEL,ITEM 14. 34 (GREEN 3. SLOPE 3/4"ANGLE VALVE, 9 29 y TINT) 18 12 ITEM 9,DOWN TOWARD SLOPE 34 14 BACK OF VALVE TO DOWN ® 34 26 34 FACILITATE SUFFICIENT 8 LOW BODY DRAINAGE. 19 34 27 = 4. ALL FITTINGS AND NIPPLES 36 ARE GALVANIZED. LOCATION FOR OPTIONAL 30 21 1 5. CH:COMMON HARDWARE ELECTRICALLY r 32 17 13 6. ITEMS 45-48 INCLUDED SUPERVISED 3 ONLY IN PRE-TRIMMED N.O.ALARM 41 30 VALVE ASSEMBLIES AS CONTROL 39 40 APPLICABLE;OTHERWISE VALVE 10 SEPARATELY ORDERED. 39 i' 23 30 40 4 INCH(DN100) 24 34 84 43 MODEL DPV-1 1 DRY PIPE VALVE 33 42 31 I (FxG SHOWN) 25 7 9 20 CQ CD 0 33 38 � 46 37 CD �(D 2 11 44 NO. DESCRIPTION QTY P/N 22 1 250 psi/1750 kPa 28 3 45 Air Pressure 35 Gauge.. .........1 92-343-1-012 32 17 2 300 psi/2000 kPa Water Pressure Gauge.. .........1 92-343-1-005 3 1/4"Gauge Test NO. DESCRIPTION QTY P/N Valve. .. .........2 46-005-1-002 4 1/4" Pressure 21 1/2"x 1/4" Reducing Relief Valve.......1 92-343-1-020 Bushing ....... ..1 CH 5 1/2"Angle Valve...1 46-048-1-004 22 1/2" Union...... ..1 CH NO. DESCRIPTION QTY P/N 6 Model AD-1 23 3/4" Union...... . . 1 CH 41 3/4"x 2" .. .. ... ..1 CH Automatic 24 1/2"90'Elbow.. .. 1 CH 42 3/4"x 3" .. .. ... ..1 CH Drain Valve .. ... ..1 52-793-2-004 25 1/2"45'Elbow....1 CH 43 1"x 4".. .. .. ... ..1 CH 7 1/2" Ball Valve .. ..1 46-050-1-004 26 1/2"Cross........1 CH 44 2"x 4-1/2". .. ... ..1 CH 8 1/2"Swing 27 1/2"Tee .........2 CH COMPONENTS INCLUDED ONLY IN Check Valve . ... ..1 46-049-1-004 28 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 9 3/4"Angle Valve. ..1 46-048-1-005 Reducing Tee .....2 CH 10 3/4"Swing 29 1/2"x 1/2"x 1/4" 45 Model BFV-300 Butterfly Check Valve .... ..1 46-049-1-005 Reducing Tee .....1 CH Valve,4"(DN100)..1 59300GO40W 11 2"Angle Valve .. ..1 46-048-1-009 30 3/4"x 1/2"x 3/4" 46 Butterfy Valve 12 Drip Funnel Reducing Tee .....3 CH Assembly Component: Connector... ... ..1 92-211-1-005 31 1"x 1"x 1/2" GxG DPV-1 Valves, 13 Drip Funnel Reducing Tee ... ..1 CH Figure 577 Coupling, Bracket. .........1 92-211-1-003 PIPE NIPPLES: 4"(DN100) .......1 57740ACP 14 Drip Funnel.......1 92-343-1-007 32 1/4"x 3" ....... ..2 CH FxF,FxG DPV-1 Valves, 15 3/32"Vent 33 1/2"x Close .... ..2 CH Figure 71 Flange Adapter, Fitting .. .........1 92-032-1-002 34 1/2"x 1-1/2".... ..7 CH 4"(DN100) .......1 7140S 16 1/4"Tube, 35 1/2"x 2" ....... ..1 CH 47 Waterflow Pressure 24" Long.........1 CH 36 1/2"x 2-1/2".... ..1 CH Alarm Switch, 17 1/4" Plug.........2 CH 37 1/2"x 3" .........1 CH Model PS10-2.....1 25710 18 1/2" Plug.........2 CH 38 1/2"x 3-1/2"......1 CH 48 Low Air Pressure 19 3/4" Plug.........1 CH 39 3/4"x Close ......2 CH Alarm Switch, 20 1" Plug . .........1 CH 40 3/4"x 1-1/2"......2 CH Model PS40-2.....1 25730 FIGURE 4-PART 3 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 14 of 20 NOTES: 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM AIR SUPPLY SYSTEM CONTROL VALVE AIR SUPPLY (NORMALLY PRESSURE OPEN) 1/2 INCH NPT GAUGE CONNECTION SYSTEM LOW BODY FOR SYSTEM / WATER DRAIN VALVE AIR SUPPLY SUPPLY (NORMALLY PRESSURE CLOSED) 1 INCH NPT GAUGE CONNECTION ®AUTOMATIC FOR LOCAL GROOVED DRAIN VALVE SPRINKLER COUPLING OR FLANGE ° 1/2 INCH NPT DRIP FUNNEL ADAPTER CONNECTION e FOR OPTIONAL MAIN / ® ACCELERATOR DRAIN VALVE ALARM (NORMALLY 2 INCH NPT TEST VALVE 1-1/4 INCH NPT CLOSED) CONNECTION SYSTEM (NORMALLY WATERFLOW CONNECTION 6 INCH(DN150) SHUT-OFF CLOSED) 3/4 INCH NPT PRESSURE TO DRAIN MODEL DPV-1 VALVE CONNECTION ALARM TO DRAIN DRY PIPE VALVE (NORMALLY FOR WATER SWITCH (GxG SHOWN) OPEN) MOTOR ALARM FIGURE 5-PART 1 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT 1/2 INCH NPT NOTES: B CONNECTION CONNECTION 4. SLOPE 3/4"ANGLE VALVE AND ��' d FOR OPTIONAL FOR SYSTEM 3/4"x 4-1/2" NIPPLE(OF ASSEMBLY B) O va SYSTEM AIR PRESSURE AIR SUPPLY INTO DRIP FUNNEL TO FACILITATE AIR SUPPLY SWITCH SUFFICIENT LOW BODY DRAINAGE. PRESSURE AIR SUPPLY DRIP GAUGE \, CONTROL VALVE LOW BODY 112 INCH NPT FUNNEL— (NORMALLY DRAIN VALVE CONNECTION SLOPE 1 INCH NPT OPEN) (NORMALLY FOR OPTIONAL TO FIT CONNECTION CLOSED) ACCELERATOR 1/2 INCH NPT FOR LOCAL CONNECTION SPRINKLER A o o AUTOMATIC FOR WATERFLOW 0 o DRAIN VALVE PRESSURE ALARM (7) SWITCH 0 0 MAIN o o B 3/4 INCH NPT CONNECTION DRAIN VALVE FOR WATER (NORMALLY I MOTOR ALARM CLOSED) D 2 INCH NPT CONNECTION 6 INCH(DN150) / TO DRAIN MODEL DPV-1 DRIP i D(FxF SHOWN)RY PIPE E FUNNEL (; NOTES: 1. INSTALL TRIM ASSEMBLIES IN ALPHABETICAL ORDER. / ALARM 2. SEE FIGURE 2 FOR VALVE PORT 1-1/4 INCH NPT SYSTEM TEST VALVE IDENTIFICATION. CONNECTION WATER SUPPLY (NORMALLY 3. ROUTE 1/4"TUBING TO DRIP TO DRAIN PRESSURE CLOSED) FUNNEL. GAUGE FIGURE 5-PART 2 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP102O Page 15 of 20 9 BACK OF 4 NOTES: 1. SEE FIGURE 2 FOR VALVE 4. ALL FITTINGS AND NIPPLES (( VALVE 29 PORT IDENTIFICATION. ARE GALVANIZED. 42 \\ o 35 2. ROUTE 1/4"TUBING, ITEM 16, 5. CH:COMMON HARDWARE 5 TO DRIP FUNNEL, ITEM 14. 6. ITEMS 45-48 INCLUDED 14-- 18 3. SLOPE 3/4"ANGLE VALVE, ONLY IN PRE-TRIMMED SLOPE 48 ITEM 9,AND 3/4"x 4-1/2" VALVE ASSEMBLIES AS TO FIT 35 NIPPLE, ITEM 42, INTO APPLICABLE;OTHERWISE DRIP FUNNEL, ITEM 14,TO SEPARATELY ORDERED. 1 21 26 ~ 8 40 FACILITATE SUFFICIENT 15 LOW BODY DRAINAGE. (GREEN LOCATION 35 TINT) FOR OPTIONAL 3 9 85 18 �� ELECTRICALLY 30 27 SUPERVISED 17 33 35 42 6 16 47 N.O.ALARM 11 20 43 27 35 28 CONTROL 32 31 37 VALVE � 40 31 44 10 40 i 40 41 19 23 6 INCH(DN150) 1� 42 12 MODEL DPV-1 DRY PIPE VALVE 40 (GxG SHOWN) 31 13 35 24 NO. DESCRIPTION QTY P/N 39 14 38 1 250 psi/1750 kPa 22 7 34 Air Pressure 36 35 25 Gauge.. .........1 92-343-1-012 28 2 300 psi/2000 kPa 2 Water Pressure Gauge.. .........1 92-343-1-005 3 1/4"Gauge Test Valve. .. .. .. ... ..2 46-005-1-002 33 4 1/4" Pressure 46 3 Relief Valve..... ..1 92-343-1-020 17 NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve. ..1 46-048-1-004 45 35 1/2"x 1-1/2".... ..8 CH 6 Model AD-1 36 1/2"x 2" ....... ..1 CH Automatic 37 1/2"x 2-1/2".... ..1 CH Drain Valve .......1 52-793-2-004 ® 38 1/2"x 3" ....... ..1 CH 7 1/2" Ball Valve .. ..1 46-050-1-004 ® 39 1/2"x 6" ....... ..1 CH 8 1/2"Swing 40 3/4"x 1-1/2"......5 CH Check Valve ......1 46-049-1-004 p 41 3/4"x 2" .........1 CH 9 3/4"Angle Valve...1 46-048-1-005 42 3/4"x 4-1/2"......2 CH 10 3/4"Swing 43 1"x 4".. .........1 CH Check Valve . ... ..1 46-049-1-005 44 2"x 4-1/2"... ... ..1 CH 11 2"Angle Valve .. ..1 46-048-1-009 COMPONENTS INCLUDED ONLY IN 12 Drip Funnel Connector...... ..1 92-211-1-005 PRE-TRIMMED VALVE ASSEMBLIES: 13 Drip Funnel NO. DESCRIPTION QTY P/N 45 Model BFV-300 Butterfly Bracket. ....... ..1 92-211-1-003 25 1/2"45'Elbow.. ..1 CH Valve,6"(DN150)..1 59300GO60W 14 Drip Funnel..... ..1 92-343-1-007 26 1/2"Cross .......1 CH 46 Butterfy Valve 15 3/32"Vent 27 1/2"Tee .........2 CH Assembly Component: Fitting .. .........1 92-032-1-002 28 1/2"x 1/4"x 1/2" GxG DPV-1 Valves, 16 1/4"Tube, Reducing Tee .....2 CH Figure 577 Coupling, 24" Long....... ..1 CH 29 1/2"x 1/2"x 1/4" 6"(DN150) .......1 57760ACP 17 1/4" Plug....... ..2 CH Reducing Tee .....1 CH FxF,FxG DPV-1 Valves, 18 1/2" Plug....... ..2 CH 30 3/4"90'Elbow....1 CH Figure 71 Flange Adapter, 19 3/4" Plug....... ..1 CH 31 3/4"x 1/2"x 3/4" 6"(DN150) .......1 7160S 20 1" Plug . .... ... ..1 CH Reducing Tee .....3 CH 47 Waterflow Pressure 21 1/2"x 1/4" Reducing 32 1"x 1"x 1/2" Alarm Switch, Bushing .. . . . . . . . 1 CH Reducing Tee ... ..1 CH Model PS10-2.....1 25710 22 1/2" Union. . . . . . . . 1 CH PIPE NIPPLES: 48 Low Air Pressure 23 3/4" Union... ... .. 1 CH 33 1/4"x 3" .. .. ... ..2 CH Alarm Switch, 24 1/2"90'Elbow....1 CH 34 1/2"x Close . ... ..1 CH Model PS40-2... ..1 25730 FIGURE 5-PART 3 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 16 of 20 7-1/8" _ _ 8-3/8" 14-7/8" 9-1/4" (180 mm) (213 mm) (380 mm) (235 mm) 2-1/2&3 INCH 0 ® o (DN65&DN80) 20-7/16" VALVE ® (520 mm) 16-1/8" (409,6 mm) 2-1/2 or 3 INCH ° q VALVES ° P o 0 if _ 12" 9-5/8" _ 12" __ 14" (300 mm) (245 mm) (300 mm) (355 mm) 4 INCH O a o (DN100) VALVE ® 21-7/8" ® (555 mm) d� FxF: 18-3/16"(462 mm) O �qP FxG: 18-1/4"(464 mm) ® ac GxG:18-5/16"(465 mm) o O O 11-1/2" 11-3/8" 15" 14-3/4" _ (290 mm)�~(289 mm) (380 mm) (375 mm) 6INCH (DN 150) VALVE 0 P O 24-1/2" 0 (620 mm) d b 21-7/8" O (555,6 mm) O O O FIGURE 6-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, PRE-TRIMMED VALVE TFP1020 Page 17 of 20 6-3/4" 8" 14-7/8" 9-1/4" (170 mm) (200 mm) (380 mm) (235 mm) 2-1/2&3 INCH O vc 16-9/16" ® o (DN65&DN80) (420,7 mm) VALVE ® 12-1/4" (311, 2-1/2 orr IN 3 INCH VALVES o qP �I Y 6" (150 mm) _ 12" _ 6" 12" _ 14" _ (300 mm) (150 mm) (300 mm) (355 mm) 4 INCH D Q 17-1/4" O (DN100) qP (440 mm) VALVE ® ® FxF:13-5/8"(346,1 mm) FxG: 113 1/4" 49,3 mm) .pbQ GxG:13-3/4"(349,3 mm) �qP ® DQ O 2-1/2"(65 mm) 11-1/2" 7-1/4" 15" __ 14-3/4" (290 mm) (190 mm) �_— (380 mm) (375 mm) 6INCH (DN150) VALVE O D P 18-3/4" o (475 mm) ® 16" (406,4 mm) FxF,FxG, or GxG ° D Q o �P nQ o 4-1/2" (115 mm) FIGURE 6-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, VALVE AND SEMI-ASSEMBLED TRIM TFP1020 Page 18 of 20 Step 3. Verify that the DPV-1 Valve Care and has operated, as indicated by the flow Nominal Torque Maintenance of water into the system and that all Valve Sizes lb-ft waterflow alarms operate properly. in. (N•m) (DN) The following procedures and inspec- Step 4.Close the system Main Control tions should be performed as indicated, Valve. 2-1/2 30 in addition to any specific requirements (DN65) (41) Step 5. Reset the DPV-1 Valve in of the NFPA,and any impairment must accordance with the Valve Setting 3 30 be immediately corrected. Procedure. (DN80) (41) Before closing a fire protection system Note: It is recommended that the 4 30 main control valve for maintenance requirement of NFPA 25 to annually (DN100) (41) work on the fire protection system that inspect the inside of the valve be per- 6 55 it controls,permission to shut down the formed at this time and prior to reset- (DN150) (75) affected fire protection system must be ting the DPV-1 Valve. Refer to the obtained from the proper authorities Automatic Drain Valve Inspection sub- TABLE C and notify all personnel who may be HANDHOLE COVER BOLTS affected by action. section Steps 2 through 5 for ction of MAXIMUM TORQUE tions with regard to the inspection of The owner is responsible for the the Clapper Facing. inspection,testing,and maintenance of Quarterly Waterf low Alarm Test Gauge), and then after removing the their fire protection system and devices d roceure p Handhole Cover, perform the follow- in compliance with this document, as ing steps: well as with the applicable standards Testing of the system waterflow alarms of the National Fire Protection Associa- should be performed quarterly.To test Step 1. Make sure that the Seat Ring tion (e.g., NFPA 25), in addition to the the waterflow alarm, open the Alarm is clean and free of any nicks or signifi- standards of any authority having juris- Test Valve, which will allow a flow of cant scratches. diction. Contact the installing contrac- water to the Waterf low Pressure Alarm Step 2. Remove the Clapper Assem- tor or sprinkler manufacturer regarding Switch and/or Water Motor Alarm. bly from the valve by first pulling out any questions. Upon satisfactory completion of the the Hinge Pin. Automatic sprinkler systems are rec- test, close the Alarm Test Valve. Step 3. Disassemble the Clapper ommended to be inspected, tested, Water Pressure Inspection Facing Retainer from the Clapper and maintained by a qualified Inspec- The Water Pressure Gauge is to be so that the Clapper Facing can be tion Service in accordance with local inspected monthly (per NFPA 25) to removed and inspected. Make sure requirements and/or national codes. ensure that normal system water pres- that the Clapper Facing does not show sure is being maintained. signs of compression set,damage,etc. The operational test procedure and Clapper the lace waterflow pressure alarm test pro- Air Pressure Inspection Replace PP Facing if there is cedure will result in operation of the The Air Pressure Gauge is to be any signs of wear. associated alarms. Consequently, inspected monthly (per NFPA 25) to Step 4. Clean the Clapper Facing, notification must first be given to the ensure that normal system air pressure Clapper, and Clapper Facing Retainer, owner and the fire department, central is being maintained. and then reassemble the Clapper station,or other signal station to which Automatic Drain Valve Inspection Assembly. the alarms are connected. The Automatic Drain Valve should be Step 5.Reinstall the Clapper Assembly Annual Operation Test Procedure inspected monthly (per NFPA 25) by with its Hinge Pin. Note:Unless otherwise noted, refer to depressing the plunger and check- Figure 3, 4, or 5 to identify functional g in to ensure that the Automatic Drain Step 6. Install Handhole Cover: trim components. Valve is not discharging water and/or a. Align Handhole Cover Gasket and air. A discharge of water and/or air is Handhole Cover in proper orien- Proper operation of the DPV-1 Valve an indication that the air and/or water tation with valve body(Ref. Figure (i.e.,opening of the DPV-1 Valve during seats are leaking, which could subse- 1)and hold in place a fire condition) should be verified at quently cause a false operation should least once a year as follows: the intermediate chamber become b. Apply o Hex E It t rea s equiv- Step 1. If necessary, prevent water inadvertently pressurized. anent)to Hex Bolt threads Hand- from flowing beyond the riser by: If leakage is present, take the DPV-1 c. Insert Hex Bolts through Hand- • Close the Main Control Valve Valve out of service (i.e., close the hole Cover Gasket and le main control valve,open the main drain Cover, hand-tighten inttoo valve • Open the Main Drain Valve valve,close the air supply control valve, body • Open the Main Control Valve one turn remove the Dry Pipe Valve Accelerator d. Using crossdraw sequence to beyond the position at which water from service, as applicable, in accor- assure uniformity,wrench-tighten just begins to flow from the Main dance with its Technical Data Sheet Hex Bolts to appropriate torque Drain Valve (Refer to TFP1105 for the VIZOR or values(Ref.Table C) • Close the Main Drain Valve TFP1112 for the ACC-1), and open the e. Inspect to assure all Hex Bolts Inspector's Test Connection to relieve are securely tightened Step 2. Open the system Inspector's the system air pressure to 0 psig as Test Connection. indicated on the System Air Pressure TFP1020 Page 19 of 20 Limited Specify:6 in. DPV-1 Pre-Trimmed Valve Accessories Assembly, (specify) End Connection, Refer to Technical data Sheets describ- Warranty P/N (specify): ing the following accessories, as Flange x Flange...............52-310-3-060 applicable. For warranty terms and conditions,visit Flange x Groove...............52-310-3-460 Specify: Description, P/N (specify): www.tyco-fire.com. Groove x Groove..............52-310-3-960 Model PS10-2 Potter Electric Waterflow Pre-Trimmed DPV-1 Assemblies Pressure Alarm Switch ...............25710 Ordering without Butterfly Valve (Ref.Potter Electric Technical Data Sheet) Specify:4 in. DPV-1 Pre-Trimmed Valve Model PS40-2 Potter Electric Low Air Pressure Alarm Switch ...............25730 Procedure Assembly without Butterfly, (Specify) (Ref.Potter Electric Technical Data Sheet) End Connection, P/N (specify): Model WMA-1 Contact your local distributor for avail- Water Motor Alarm.............52-630-1-001 ability.When placing an order.indicate Flange x Flange...............52-310-4-440 (Ref.Technical Data Sheet TFP921) y p g Flange xGroove...............52-310-4- 40 the full product name and Part Number Model AMD-1 (P/N). Specify:6 in. DPV-1 Pre-Trimmed Valve Air Maintenance Device.........52-324-2-002 Assembly without Butterfly, (specify) (Ref.Technical Data Sheet TFP1221) Standard DPV-1 Dry Pipe Valve End Connection, P/N (specify) Model AMD-2 ( p y)� Air Maintenance Device.........52-326-2-001 ANSI standard outside diameter(O.D.) pipe size with grooved or ANSI drilled Flange x Flange...............52-310-4- 60 (Rod el AMDc31 Data Sheet TFP1231) Flange xGroove...............52-310-4-460 flange end connections and NPT Nitrogen Maintenance Device....52-328-2-001 threaded ports. Standard Galvanized (Ref.Technical Data Sheet TFP1241) Specify: (specify size) Model DPV-1 Semi-Assembled DPV-1 TrimNote: Valves with NPT threaded ports Replacement Valve Parts Dry Pipe Valve with(specify) End Con- are intended for use with the Standard Specify: (description) for use with nections, P/N (specify): Galvanized Semi-Assembled StandDPV-ard (specify size) Model DPV-1 Dry Pipe Groove x Groove, Valve Trim described in Figures 3, 4 Valve, P/N (see Figure 1). ANSI 2.in.( in. 5)G G.O.D.Grooves: and 5 of this document. Replacement Trim Parts Groove e (DN65)G x G..........52-310-1-925 Specify: (description) for use with GroovexGroove, Specify: 2-1/2 and 3 in. DPV-1 (specify size) Model DPV-1 Dry Pipe ANSI 3.50 in.(88,9 mm)O.D.Grooves: Semi-Assembled Galvanized Trim, 3 in.(DN80)G x G .............52-310-1-930 P/N 52-309-2-005 Valve, P/N (see Figures 3, 4, or 5). Groove x Groove, Other DPV-1 Dr Pipe Valves ANSI 4.50 in.(114,3 mm)O.D.Grooves: Specify: 4 in. DPV-1 Semi-Assembled Y p 4 in.(DN100)G x G ............52-310-1-940 Galvanized Trim, P/N 52-309-2-001 Notes: Other DPV-1 Dry Pipe Valves Flange x Groove, are valves ordered with any combi- ANSI Flange x ANSI 4.50 in.(114,3 mm)O.D. Specify: 6 in. DPV-1 Semi-Assembled nation of flange drilling, pipe groove Groove: Galvanized Trim, P/N 52-309-2-002 outside diameter(0.D.), or port thread 4 in.(DN100)F x G.............52-310-1-440 specification not offered as Standard Flange x Flange, Optional Electronic Accelerator: s p ANSI Flanges: DPV-1 Dry Pipe Valves. 4 in.(DN100)F x F.............52-310-1-040 VIZOR Electronic Dry Pipe Groove xGroove, Accelerator(with Trim) Valves with NPT threaded ports are ANSI 6.62 in.(168,3 mm)O.D.Grooves: (Ref.Technical Data Sheet TFP1105) intended for use with the Standard 6 in.(DN150)G x G ............52-310-1-960 Galvanized Semi-Assembled DPV-1 Flange x Groove, Specify: VIZOR Electronic Dry Pipe Valve Trim described in Figures 3, 4 ANSI Flange x ANSI 6.62 in.(168,3 mm)O.D. Accelerator for use with the 4 or 6 in. and 5 of this document. Valves with ISO Groove: TYCO Model DPV-1 Dry Pipe Valve threaded ports are intended for use 6 in.(DN150)F x G.............52-310-1-460 Trim, P/N 52-312-3-001 Flange x Flange, with special order trim that is provided ANSI Flanges: Optional Mechanical Accelerator: by local distributors to meet the spe- 6 in.(DN150)F x F.............52-310-1-060 Model ACCA Dry Pipe Accelerator cific needs of certain localities. Please Pre-Trimmed DPV-1 Assemblies (Ref.Technical Data Sheet TFP1112) contact your local distributor regard- with ButterflyValve regard- ing valves and valve trim for specific Specify: Model ACC-1 Dry Pipe localities. Specify: 2-1/2 in. DPV-1 Pre-Trimmed Accelerator, P/N 52-311-1-001, Valve Assembly,Grooved End Connec- and Galvanized Accelerator Trim Specify: (specify size) Model DPV-1 tions, P/N 52-310-3-925 for Model DPV-1 Dry Pipe Valve, Dry Pipe Valve with(specify) End Con- Specify:3 in. DPV-1 Pre-Trimmed Valve P/N 52-311-2-010 nections and (specify NPT or ISO) Assembly, Grooved End Connections, Optional 600 PSI Water Pressure threaded ports, P/N (specify): P/N 52-310-3-930 Gauge: Other 2-1/2 in. (DN65)Valves Specify:4 in. DPV-1 Pre-Trimmed Valve Specify: 600 PSI Water Pressure with NPT Threaded Ports Assembly, (specify) End Connection, Gauge, P/N 92-343-1-004 Groove x Groove, s ecif 3.00 in.(76,1 mm)O.D. P/N (specify): Grooves.....................52-309-1-930 Flange x Flange...............52-310-3-040 Flange x Groove...............52-310-3-440 Groove x Groove..............52-310-3-940 TFP1020 Page 20 of 20 Other 2-1/2 in. (DN65)Valves Other 4 in. (DN100)Valves Other 6 in. (DN150)Valves with ISO Threaded Ports with ISO Threaded Ports with ISO Threaded Ports Groove x Groove, Groove x Groove, Groove x Groove, ANSI 2.88 in.(73,0 mm)O.D. ANSI 4.50 in.(114,3 mm)O.D. ANSI 6.62 in.(168,3 mm)O.D. Grooves.....................52-309-1-920 Grooves.....................52-309-1-923 Grooves.....................52-309-1-925 Groove x Groove, Flange x Groove, Groove x Groove, 3.00 in.(76,1 mm)O.D. ISO Flange x ANSI 4.50 in.(114,3 mm)O.D. 6.50 in.(165,1 mm)O.D. Grooves.....................52-309-1-940 Groove......................52-309-1-213 Grooves.....................52-309-1-945 Flange x Flange, Flange x Groove, Other 3 in.(DN80)Valves ISO Flanges..................52-309-1-113 ISO Flange x ANSI 6.62 in.(168,3 mm)O.D. with ISO Threaded Ports O Groove......................52-309-1-215 Other 6 in. DN150 Groove x Groove, ( )Valves Flange x Groove, ANSI 3.50 in.(88,9 mm)O.D. with NPT Threaded Ports ISO Flange x 6.50 in.(165,1 mm)O.D. Grooves.....................52-309-1-922 Groove x Groove, Groove......................52-309-1-315 DN100 Valves 6.50 in.(165,1 mm)O.D. Flange x Flange, Other 4 in. ( ) Grooves.....................52-309-1-935 ISO Flanges..................52-309-1-115 with NPT Threaded Ports Flange x Groove, Flange x Groove, ANSI Flange x 6.50 in.(165,1 mm)O.D. ISO Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-435 Groove......................52-309-1-253 Flange x Groove, Flange x Groove, ISO Flange x ANSI 6.62 in.(168,3 mm)O.D. AS Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-255 Groove......................52-309-1-613 Flange x Groove, Flange x Groove, ISO Flange x 6.50 in.(165,1 mm)O.D. JIS Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-335 Groove......................52-309-1-813 Flange x Groove, Flange x Flange, AS Flange x ANSI 6.62 in.(168,3 mm)O.D. ISO Flanges..................52-309-1-133 Groove......................52-309-1-615 Flange x Flange, Flange x Groove, AS Flanges...................52-309-1-513 AS Flange x 6.50 in.(165,1 mm)O.D. Flange x Flange, Groove......................52-309-1-635 JIS Flanges ..................52-309 1-713 Flange x Groove, JIS Flange x ANSI 6.62 in.(168,3 mm)O.D. Groove......................52-309-1-815 Flange x Groove, JIS Flange x 6.50 in.(165,1 mm)O.D. Groove......................52-309-1-835 Flange x Flange, ISO Flanges..................52-309-1-135 Flange x Flange, AS Flanges...................52-309-1-515 Flange x Flange, JIS Flanges ..................52-309-1-715 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone A-215-362-0700®2018 Johnson Controls.All rights reserved.All specifications and other Information shown were current as of document revision date and are subject to change without notice. Johnson 400 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls LOCTITE is a registered trademark of Henkel Corporation tqCaRre Suppression & Building Products Technical Services 800-381-9312 1+1-401-781-8220 www.tyco-fire.com Model CV-1F Check Valves 2 to 12 Inch (DN50 to DN300) General The Model CV-1F Check Valves described herein must be installed Descry t/on and maintained in compliance with this N document and with the applicable stan- The TYCO Model CV-1 F Check Valve is dards of the National Fire Protection a compact and rugged swing-type unit Association, in addition to the stan- that allows water flow in one direction dards of any authorities having juris- and prevents flow in the opposite direc- diction. Failure to do so may impair the o' tion. A resilient elastomer seal facing performance of this device. on the spring-loaded clapper ensures Owners are responsible for maintain- a leak-tight seal and non-sticking oper- ing their fire protection system and ation.The Model CV-1 F Check Valves devices in proper operating condition. are designed to minimize water hammer The installing contractor or manufac- • caused by flow reversal. turer should be contacted with any The Model CV-1F Check Valve is questions. furnished with grooved ends and can be installed using Grinnell Grooved Technical Couplings or GRINNELL Figure 71 Installation Flange Adapters. The Model CV-1F Data Check Valves have been designed The Model CV-1 F Check Valves are with a removable cover for ease of field to be installed in accordance with the maintenance. These valves can be Approvals following instructions: installed horizontally(with cover in the UL, C-UL, and FM g upward position)or vertically with the Sizes 1.The arrow cast on the Body must flow in the upward direction. Refer to 2 to 12 Inch (DN50 to DN300) point in the direction of the flow. Figure 4. 2.Valves installed vertically must be Maximum Working Pressure positioned with the flow in the up- A Maintenance Check Valve Kit 300 psi (20,7 bar) ward direction. (TFP1555) is available to allow the maintenance procedure of back- Valve Assembly Finish 3.Valves installed horizontally must be flushing through the fire department Red, non-lead paint positioned with the Cover facing up. connection without removing the Model Refer to Figure 4. CV-1F Check Valve from the pipe line. 4.Grooved end pipe couplings used The Model CV-1F Check Valves area with the Model CV-1F Check Valve redesign for the Central Figure 590F must and GRINNELL Figure 590F. manufacturer's instructions. be installed in accordance with EMM Never remove any piping component nor correct or modify any piping defi- ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 4 OCTOBER 2010 TFP1550 TFP1550 Page 2 of 4 B A C O ♦ O.D. D — NPT 1/2" NPT j E F Nominal Pipe Size Nominal Dimensions Inches(mm) Cover Approx. Bolt Torq. Weight ANSI O.D. Lbs.-ft. Lbs. Inches Inches A B C D E F J (Nm) (kg) DN (mm) 2 2.375 6.75 4.38 2.55 2.57 3.25 4.75 1.62 18 9.0 DN50 (60,3) (171,5) (111,3) (64,8) (65,3) (82,3) (120,7) (41,5) (25) (4,5) 2-1/2 2.875 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.0 DN65 (73,0) (203,2) (147,3) (86,6) (86,4) (98,6) (152,4) (43,2) (54) (4,5) 76,1 - 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.00 DN65 (76,1) (203,2) (147,3) (86,6) (86,4) (98,6) (152,4) (43,2) (54) (4,5) 3 3.500 8.37 5.76 3.60 3.40 3.88 6.00 1.70 39 11.0 DN80 (88,9) (212,6) (146,3) (91,4) (86,4) (98,6) (152,4) (43,2) (54) (5,0) 4 4.500 9.63 6.74 4.61 3.63 4.56 7.13 1.84 50 25.0 DN100 (114,3) (244,6) (171,2) (117,1) (92,2) (115,1) (181,1) (46,7) (69) (11.3) 139.7 - 10.50 7.50 5.29 4.20 4.90 7.60 1.90 39 29.0 DN125 (139.7) (266,7) (190,5) (134,4) (106,7) (124,5) (193,0) (48,3) (54) (13.2) 5 5.563 10.50 7.50 5.29 4.20 4.90 7.60 1.90 39 29.0 DN125 (141,3) (266,7) (190,5) (134,4) (106,7) (124,5) (193,0) (48,3) (54) (13,2) 165.1 - 11.50 8.05 5.75 4.50 5.00 7.60 1.48 60 47.0 DN150 (165.1) (292,1) (204,5) (146,1) (114,3) (127,0) (193,0) (37,6) (82) (21,3) 6 6.625 11.50 8.05 5.75 4.50 5.00 7.60 1.48 60 47.0 DN150 (168,3) (292,1) (204,5) (146,1) (114,3) (127,0) (193,0) (37,6) (82) (21,3) 8 8.625 14.00 10.25 7.75 5.62 5.45 8.40 2.20 120 66.0 DN200 (219,1) (355,6) (260,4) (196,9) (142,7) (138,4) (213,4) (58,9) (164) (29,9) 10 10.750 18.00 13.00 10.21 6.38 7.50 10.50 3.00 130 109.7 DN250 (273,1) (457,2) (330,2) (259,3) (162.1) (190.5) (266,7) (76,2) (178) (49,4) 12 12.750 21.00 14.28 11.31 7.26 7.62 10.62 2.75 130 151.0 DN300 (323,9) (533,4) (362,7) (287,2) (184,4) (193,5) (269,7) (69.9) (178) (68,0) FIGURE 1 MODEL CV-1F CHECK VALVES NOMINAL DIMENSIONS TFP1550 Page 3of4 8 8 4,16 18 17 9 5 2 SEE 2 7 9 VIEW A 3 2"-8" 2 10"-12" 7 5 (DN50-DN200) (DN250-DN300) VIEW A 13 D 5 13 SEE , 11,16 DETAIL B 11 14,16 19 6 5 6 1 15 2"-8" 10"-12" (DN50-DN200) (DN250-DN300) DETAIL B Detail Part Material Oty. Detail Part Material Oty. Detail Part Material Qty. 1 Body Ductile Iron 1 6 Clapper EPDM 1 14 Locknut Stainless 1 Facing Grade"E" Steel 2 Cover Ductile Iron 1 7 Spring Stainless 1 15 Plug- Cast Iron 2 Steel 1/2-14 NPT 3 Cover Nitrile Rubber 1 8 Hinge Stainless 1 16 Adhesive Thread AR Gasket Shaft Steel Sealer Hex Cap Steel,Zinc AR 9 Retaining Stainless AR 17 Nameplate Aluminum 1 4 Screw Plated Ring Steel Clapper Stainless Retention Stainless 2 -8 Steel 11 Bolt Steel 1 18 Rivet Steel 2 5 (DN50-200) 1 Clapper Retaining Stainless Stainless 10"-12- Ductile Iron 13 Disc Steel 1 19 Spacer Steel 1 (DN250-300) FIGURE 2 MODEL CV-IF CHECK VALVES ASSEMBLY FLOW RATE IN LITRES PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 4.0 0 0 0,30 h = Q o a a 3.0 V� o z `? 1 vz Q2 ^rye o z _ �h o Q rr 2.0 ry 20 Q= o0 o m �z ° 20 VZ =� o W 00 W CJ h _ O h p `° QC Co � =`v �0 0,10 o a w 20 2 0,09 W ii zEL cn cb U� 0,08 d u) z 1.0 0= ?V 0,07 Q a O 0.9 '� JCL 0,06 ? a 0.8 :5i z 0.7 I I III !HAW0'05 0.6 0,04 0.5 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) FIGURE 3 MODEL CV-1F CHECK VALVES PRESSURE LOSS DATA TFP1550 Page 4 of 4 Care and Limited TFSBP was informed about the possi- bility of such damages, and in no Maintenance Warranty event shall TF liability exceed an amount equal too the the sales price. Products manufactured by Tyco Fire The foregoing warranty is made in lieu Suppression & Building Products of any and all other warranties. express Before closing a fire protection system (TFSBP) are warranted solely to the or implied, including warranties of main control valve for maintenance original Buyer for ten(10)years against merchantability and fitness for a partic- work on the fire protection system defects in material and workmanship ular purpose. that it controls, obtain permission to when paid for and properly installed shut down the affected fire protection and maintained under normal use This limited warranty sets forth the system from the proper authorities and and service. This warranty will expire exclusive remedy for claims based on notify all personnel who may be affect- ten (10) years from date of shipment failure of or defect in products, materi- ed by this decision. by TFSBP. No warranty is given for als or components,whether the claim is products or components manufac- made in contract,tort, strict liability or After placing a fire protection system tured by companies not affiliated by any other legal theory. in service, notify the proper authorities ownership with TFSBP or for products This warranty will apply to the full and advise those responsible for moni- and components which have been extent permitted by law.The invalidity, toring proprietary and/or central station subject to misuse, improper instal- in whole or part, of any portion of this alarms. lation, corrosion, or which have not warranty will not affect the remainder. Responsibility lies with owners for the been installed, maintained, modified inspection,testing,and maintenance of or repaired in accordance with appli- Ordering their fire protection system and devices cable Standards of the National Fire in compliance with this document, as Protection Association,and/or the stan- procedure well as with the applicable standards of dards of any other Authorities Having the National Fire Protection Association Jurisdiction. Materials found by TFSBP Contact your local distributor for avail- (for example, NFPA 25), in addition to to be defective shall be either repaired ability.When placing an order, indicate the standards of any authority having or replaced, at TFSBP's sole option. the full product name and Part Number jurisdiction. The installing contractor TFSBP neither assumes, nor authorizes (P/N). or product manufacturer should be any person to assume for it, any other contacted relative to any questions. obligation in connection with the sale of Model CV-1F Check Valves Any impairments must be immediately products or parts of products.TFSBP Specify: size and P/N (below). corrected. shall not be responsible for sprinkler p p 2"(DN50)...............P/N 59-590-0-020 or Automatic sprinkler systems are recom- system design errors or inaccurate incomplete information supplied by y 2-1/2-(DN65)............P/N 59-590-0-025 mended to be inspected, tested, and 76,1 mm(DN65) .........P/N 59-590-0-076 maintained by a qualified Inspection Buyer or Buyer's representatives. 3-(DN80)...............P/N 59-590-0-030 Service in accordance with local In no event shall TFSBP be liable, in 4-(DN100)..............P/N 59-590-0-040 requirements and/or national codes. contract, tort, strict liability or under 139,7 mm(DN125) .......P/N 59-590-0-139 any other legal theory, for inciden- 5-(DN125)..............P/N 59-590-0-050 tal, indirect, special or consequential 165,1 mm(DN150) .......P/N 59-590-0-165 damages, including but not limited to 6-(DN150)..............P/N 59-590-0-060 labor charges, regardless of whether 8 (DN200)..............P/N 59-590-0-080 10-(DN250).............P/N 59-590-0-100 12-(DN300).............P/N 59-590-0-120 OUTLET COVER FLOW i O INLET - OUTLET COVER _ ( 0� INLET FLOW VERTICAL ORIENTATION HORIZONTAL ORIENTATION FIGURE 4 MODEL CV-1F CHECK VALVES INSTALLATION Copyright© 2008-2010 Tyco Fire Suppression&Building Products.All rights reserved. CP� POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -400 to 150OF(-401 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires DC Bells-Terminal strip * APPa°°E Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30'to 150°F(-341 to 661C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. A WA R N I N G In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5400776-REV Y PAGE 1 OF 2 5/08 (E) POTTER BELLS ® The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS 10" WHITE(IN) WHITE(OUT) ° 8" I (200) FROM CONTROL 6" I I PANEL OR (150) I PRECEDING BELL I I o BLACK(OUT)BLACK(E� VOj CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 211/16" (68) DWG#776-1 NOTES: 1.WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2.END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWGtt 7763 Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance 0 5 3/4" _ 3 3/8" 5" To Next (146) 0 (86) (127) Device or End-of-Line Resistor 3 3/8" 1 5/8, (8� (41) 4 1/4" (108) Installation DWG#776-2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. O 2. Remove the gong. o 3. Connect wiring(see Fig.3). 0 4. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). ° 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). l 6. Test all bells for proper operation and observe that they can BBx-1 / be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 Spare Sprinkler Head Storage Cabinet 111S1S7r-_1L FPPI° Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts"to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Material: Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct Painted Plain Steel number of spare sprinkler is as follows: Finish: 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, Red enamel not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers, '/2 or 3/4 6 Spare sprinklers, '/2 or 3/4 6 Spare, ESFR, 1/2, 3/4 or 1" Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers'/2 or 3/ is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers the cabinet, securing the cabinet securely to the wall. The insert the correct 36 Spare sprinklers number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. TT AT AT U Schedule • and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal .- Size (in) Nominal O.D. 1 1.315 1.097 1.41 Ibs/ft 91 1 1/4 1.660 1.442 1.81 Ibs/ft 61 1 1/2 1.900 1.682 2.09 Ibs/ft 61 2 2.375 2.157 2.64 Ibs/ft 37 2 1/2 2.875 2.635 3.53 Ibs/ft 30 3 3.500 3.260 4.34 Ibs/ft 19 4 4.500 4.260 5.62 Ibs/ft 19 Schedule 40 Pipe 116� Nominal Pipe Size (in) Nominal O.D. (in) 1 1.315 1.049 1.68 Ibs/ft 70 1 1/4 1.660 1.380 2.27 Ibs/ft 51 1 1/2 1.900 1.610 2.72 Ibs/ft 44 2 2.375 2.067 3.66 Ibs/ft 30 2 1/2 2.875 2.468 5.80 Ibs/ft 30 3 3.500 3.068 7.58 Ibs/ft 19 4 4.500 4.026 10.80 Ibs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. QiIZ 1819 Clarkson Road Foradditonal inforpmation, C �L usA Chesterfield, MO 63017 contact our salesperson (800)325-4467 today at(800)325-4467 or LISTED BULL MOOSE TUBE COMPANY FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada F M A UP- company e-mail: sales(c�bullmoosetube.com call(800)882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 BULL MOOSE® EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET TUBE APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based • ASTM A795,Type E, Grade A paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate,the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain • NFPA-14 minimal bacterial count after multiple flushes (25) of the pipe. • CIVIL DEFENSE APPROVAL— • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC&FM listed for roll-groove, plain-end and welded joints for wet, dry, Every length of BUII Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer,type • LEED v4 Certified of pipe,size,and length. mom 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4,310 7 JEMPtVWe'11gJnT(10F1.222 1.844 2.330 2.809 3.361 4,968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7,144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY U1 C U1 FM L SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments O Eddy Flow-Black Eddy Flow-Hot Dip Galvanized BULLT/[OOSETUBE. - 00 00 115 Standard Duty - i The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines,including CPVC pipes, in fire sprinkler systems.A knurled insert nut helps simplify vertical adjustments and flared edges on the base(1/2"to 4"sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe(1/2"to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non-insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA°for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society(MSS)SP-58(Type 10) �- -RS C 8 A OD �F Material:Steel FM Finish: Pregalvanized C UL US wv►•oveo Outer Diameter Rod Size Static Load Part Number Pipe Size OD RS A f3 C F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 3001b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 1b cULus,FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16'* 3001b cULus,FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 1b cULus,FM 1150150EG 1 1/2" 1.900" 3/8" 3 13/16" 1 5/8" 15/16" 300 lb cULus,FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 lb cULus,FM 1150250EG 2 1/2" 2.875" 3/8" 5 15/16" 3 7/16" 2" 5251b cULus,FM 115030DEG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 lb cULus,FM 1150350EG 3 1/2" 4.000" 3/8" 7 1/16" 3 3/4" 1 15/16" 585 lb cULus,FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 lb cULus,FM 1150500EG 5" 5.563" 1/2" 9 13/16" 4 3/4" 2 1/4" 1,000[b cULus,FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 lb cULus.FM 1150800EG 8" 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus,FM nJent CADDY FM is a registered certification mark of FM Approvals LLC,LTD.NFPA is a registered trademark of National Fire Protection Association,Inc.UL,UR,cUL,cUR,cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials,Instruction sheets are available at www.erico.com and from your nVent customer service representative.Improper installation,misuse,misapplication or other failure to completely follow nVent'a instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ®2019 nVent All rights reserved nVent,nVent CADDY,nVent ERICO,nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners.nVent reserves the right to change specifications without prior notice. v, mkiri CADDY / • © Seismic Braces V `11111�:p Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Material Specifications Size Range Service Pipe Size:T'-12,DN25-DN100 - Material Carbon Steel Clamp and Hardware.Ductile Iron Brace Member Attachment Fitting. r Finish s ❑ Plain ❑ Clamp:Hot Dipped Galvanized per ASTM A153 cL us Fnn ❑ Brace Member Attachment Fitting: LISTED APPROVED Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and lateral brace clamp designed to connect a piping system to a brace O O member.The AF730 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).FM Tested(ANSI/FM 1950-16). FIG.AF730 Dimensions and Weight Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Size A B Y Weight Features In./mm In./mm In./mm Ibs/kgs Torque offset screw and nuts provide a visual 1"(DN25) 7.6 193 2.49 1.13 indication that the desired installation torque 11/2"(DN32) 8.0 203 2.55 1.13 values have been achieved. 11/2" DN40 8.2 208 2.64 1.20 ordering ( ) Specify figure number,service pipe size,finish, 2"(DN50) 8.7 221 2.78 1.26 and description. 21/2" 9.2 234 2.92 1.32 DiscLaimer: ASC Engineered Solutions does not provide any warranties 3"(DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4"(DN100) 10.8 274 3.38 1.53 are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been,or are used. 8" 15.2 386 6.40 2.90 Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered Solutions*"^brand bracing components are designed to be compatible ONLY with other AFCON� ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service V.,O `11111�:p Size Pipe Pipe 30°-44° 45`-59` 60°-90° Listed 30`-44` 45°-59° 60°-90° Listed VAN VAN VAN IVAN IVAN VAN VAN VAN Sch.A Mega-Thread 1 Sch.40 MLT/GL 340 480 588 680 340 480 588 680 (DN25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 EZ-Thread Mega-Flow O Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) Metric Pipe EEddd Flow Longitudinal Application ThreaEZ-Thread Mega-Flow MLT/GL 11/2 Sch.10 Mega-Thread Sch.40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo 0 EZ-Thread Mega-Flow 21/2 Sch.10 Eddy Flow Sch.40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 Sch.10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 3 Sch.40 Eddy Flow (DN80) Metric Pipe Fire-Flo 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 51, Sch.10 _ Sch.40 Sch.10 942 1333 1632 1885 942 1333 1632 1885 6 Sch.40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch.10 8" 0.188"Wall - Riser Application Sch.40 10" 0.188"Wall _ Sch.40 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes&UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA13-2019 Section A.18.5.2.3. BUILdIng connections that Last' All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service VAO %IIZ:P Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN bf/kN Sch.10 Mega-Thread V Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow 0 Sch.10 MLT/GL 1Y4" Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Lon itudinatA EZ-Thread g ppllcatlon Mega-Flow Sch.10 MLT/GL 1v2" Sch.40 Mega Thread Y 800 650 790 1800 1790 2530 3100 3460 ( ) DN40 Metric Pipe Eddy Flow Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega Thread Y 830 990 1190 1620 1820 2580 3160 3530 ( ) DN50 Metric Pipe Eddy Flow Eddy Thread 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Fire-Flo EZ-Thread 2h' Sch.10 Edda Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Sch.10 Mega-Flow Lateral Application 3" Sch.40 EddyFlow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 4" Sch.10 Mega-Flow 760 1040 1270 1400 1260 1790 2190 2440 (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 51, Sch.10 _ 890 1230 1410 1550 1260 1790 2190 2440 Sch.40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 6„ Sch.10 Mega-Flow 700 940 1140 1310 950 1340 1640 1830 Sch.40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 8„ 0.188"Wall _ 990 1130 1360 1520 1540 2170 2660 2970 Sch.40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 10" 0.188"Wall _ 1020 850 1000 1100 1700 2410 2950 3290 Riser Application Sch.40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 12" 0.188"Wall _ 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. [moo Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of1.5. BUILdIng connections that Last" See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces rlrs:) / Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe.Unbolt the back nut&bolt and rotate the clamp halves over the service pipe.Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut&bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 3 Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. FIG.AF730 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1",1 Y,",1 v2",2" ASTM A53,Al 06,Al 35,or ✓ ✓ NIPS Pipe A795 Sch.40 Metric Pipe KS D 3562 ✓ ✓ DN25,DN32, EN10255H ✓ Metric Pipe DN40,DN50 GB/T3091 ✓ AS G3454 ✓ FIG.AF730 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 ✓ ✓ KS D 3537 KS D 3562 ✓ ✓ Sch.40 G B/T 3091 ✓ GB/T 3092 DN25,DN32,DN40, JIS G3452 DN50,DN 80,DN100 ✓ EN10255M asc-es.com EN 10255H Building connections that last" ss-07.20 page 4 SS-SUB-AF730-v04 20221228 ODTOLCO" www.tolco.com 00: Fig. 1000 - "Fast Clamp" Sway Brace Attachment liorniaOStPDAp of eof California OSHPD Approved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 C �L US LISTED I PS. *Additionally(UL) approved for use to brace Schedule 7 FM sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features — Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. - Installation — The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be Maximum Design Load combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs. ment component, Fig. 980, 910 or 909 to form a complete bracing 6" size — 1265 lbs. assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. FM Approved Design Loads* Brace pipe can be installed on top or bottom of pipe to be braced. 1" - 21/2" - 600 lbs. Tighten hex nuts until leaf spring is flat. It is recommended that the 3" - 4" - 700 lbs. brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Lateral Brace TOLCOO brand bracing components are desgined to be compatible ONLY with other TOLCO®brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components, in the instance that such TOLCOO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH- 951.737.5599•FAX- 951.737.0330 CUSTOMER SERVICE•800.786.5266 www,tolco.com FireLock EZ° Rigid Coupling C&f FM yds ilu4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining.The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Nominal Size 11/a 175 365 365 365 365 32 1206 2517 2517 2517 2517 11h 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 21h N/A 365 365 365 365 65 2517 2517 2517 2517 76.1mm N/A N/A 365** 365 365 2517** 2517 2517 3 N/A 365 365 365 365 80 2517 2517 2517 2517 4 365 365 365 365 100 N/A 2517 2517 2517 2517 165.1mm N/A N/A 290** 232 300 1999** 1600 2068 6# N/A 290 365 232 365 150# 1999 2517 1600 2517 rt Listed/Approved for wet and dry pipe systems(>—40°F/-400C). Please refer to the Victaulic Installation Manual(1-009H_009_009V.pdf)for details concerning when supplemental lubrication is required. *` EN-10219(L)for 76.1mm size;EN-10255(M)for 165.1mm size # Regional availability only Speciality Pipe Pipe Size psi/ a Pipe Size psi/ Pipe Size /kPa BLT 1 Ya—2 300 300 EZT 1/a—2 300 300 MT 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 DF 1 Ya—4 300 300 FF 1 Ya—4 300 300 MLT 1 Ya—2 N/A 300 2068 2068 2068 2068 2068 DT 1 Ya—2 300 300 FLF 1 Ya—4 N/A 300 ST 1'/a—2 N/A 300 2068 2068 2068 2068 EF 1 Ya—4 175 175 FLT 1 Ya—2 N/A 300 STF 1'/a—4 N/A 300 1206 1206 2068 2068 EL 1 Ya—2 300 300 FLTL 1 Ya—2 N/A 300 TF 2Ya—4 N/A 300 2068 2068 1 2068 1 1 2068 ET40 1'/a—2 300 300 GL 1 Ya—2 300 300 WLS 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 EZF 3-4 300 300 MF 1'/a-4 300 300 WST 1'/a-2 N/A 175 2068 2068 2068 2068 1206 XL 1'/a—2 300 300 2068 2068 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC_tau I1C REV_F 10.61_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.61 FireLook EZ° Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS No.-Size Dimensions-Inches/mm L�a e m b I ed ss St R1.660365 condition) Joint Assembled M Inches X 1 Ya 790 0.10 1 2 -3/8 x 2 1 2.95 1 4.77 2.70 1 4.63 1.93 1.4 32 42.4 2517 1 3514 2.54 -M10 x 2 75 121 69 1 118 49 1 0.7 1'/2 1.900 365 1035 0.10 2 -3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 -M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.375 365 1616 0.12 2 -3/8x2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 -M10 x 2 96 140 88 138 49 0.9 2'/2 2.875 365 2370 0.12 2 -3/8 x 2'/2 4.29 6.09 3.92 5.85 1.93 2.1 Y E L 65 73.0 2517 10542 3.05 M10 x 2'/2 109 155 100 149 49 1.0 76.1 mm 3.000 365 2580 0.12 2 -1/8 x 2 1/24.40 6.31 4.05 5.90 1.93 2.1 76.1 2517 11476 3.05 M10 x 2'/2 112 160 103 150 49 1.0 X 3 3.500 365 3512 0.12 2 -3/8 x 2'/2 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 M10 x 2'/2 125 170 116 164 49 1.0 _ 4 4.560 365 5805 0.17 2 -3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 M10 x 2'h 151 199 141 190 55 1.3 STYLE 009H JOINT ASSEMBLED 165.1 mm 6.500 290 9623 0.17 2 -1A x 3 Ya 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 M16 x 3 Ya 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 1 2 -1A x 3 1/47.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 -M16 x 3 Ya 1 202 281 195 305 54 2.69 Working Pressure and End Load are total,from all internal and external loads,based on standard weight (ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown in the chart on page 1,specific to pipe schedule and size. t The allowable pipe separation dimension shown is for system layout purposes only.Fire Lock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel(North America,Asia Pacific) • Red enamel(Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade"E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.9UI1C® 10.61_2 REV_F FFireLock EZ° Rigid Coupling STYLE 009H GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps con- taining the"QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling.There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade "E"Type A gaskets.These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop,that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.61 5731 REV F UPDATED 10/2011 �CtaLlIiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.61 FireLock° Fittings <&> @ LPCB See Victaulic publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-l. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC._tau IiC REV_I 10.03_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings DIMENSIONS �-CtoE� toE� I u CtoE WC - o o , •� TEto E oo tE �<e NO.001 NO.003 NO.002 NO.006 Size ,. 'Elbow 45'Elbow Straight Tee Cap Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness"T" Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs 1 Y4 1.660 0.8 0.3 32 42.4 21 1 0.1 1'/2 1.900 - - - - - 0.82 0.4 40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 L2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 1 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id 10.03_2 REV_I IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings FLOW DATA Size Equivalent Feet/meters of Straight Pipe t Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches �� �0 0.Elbow Elbow Branch Run 1'/4 I 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 Yz 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2'/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id REV-1 10.03_3 A . r�FireLockO Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009WO09H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV I UPDATED 2/2010 �CtaLJIIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 Mechanical-T° Bolted Branch Outlets SEE FM �c Vd3 LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 115 top housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30OF to+230°F/-340C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+820C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iIIIIC 1I1C® REV_O 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Appr x. Size Dimensions Weight Each minal Size D. Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs. L, F Y �Z� �� - - 2 x 1/2(a)d 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4(a)❑ 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a)n 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 w 25 3450 38.1 47 64 41 136 70 1.4 1 Y4(a)to g20N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 C5- I? 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y �Z� 65 x Yz(a)§d 920N 500 L50 2.21 2.74 _ 1.82 143 2.0 1 A 65 a) 3450 1.5 .1 70 46 1.6 70 1.4 3/a(a)§d 920N 500 i 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 _ LF 20 3450 38.1 55 70 46 143 70 1A T 1(a)§n 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 25 920N 3450 38.1 52 70 46 143 70 1.4 1'/4 t(a)0 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 1 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1�/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 Yz(a)a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 /2(a)0 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6--r • Sizes from 2 x 1/2'/50 x 15 mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)o 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3/2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/2"BSPT clearly on order. §Vds approved for fire protection services o-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St'le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. 'tl e Ma rk 920 or E Y �Z m m 920N -0.00 TABLE CONTINUED FROM PAGE 2 - 4 1/2(a)❑ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 r I 3/4(a)❑ 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 w 1(a)a 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 _ 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y4(a)tM 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 1/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2(a)to 920N 4 0 63.5 83 102 100 68 17 99 2.3 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 w 3450 69.9 73 102 68 186 118 2.9 1? 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)o 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)o 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 - 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 1 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use rig(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1/2750 x 15 mm 3450 699 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 _ 80 920 3450 88.9 97 1 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com iiiCtaILJIiiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions minal Size, Inches +0.13 Inches Inches Inches Inches Inches Inch'7h or es D. es y �Z� 0r mm mm mm mm mm m TABLE CONTINUED FROM PAGE 3 - 1 Yz t 500 2.00 3.78 4.50 3.30 8.23 3.25 1 7.0 i 139.7 x 40 920N 3450 50.8 96 114 - 84 209 83 3.2 - T 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- 50 3450 63.5 95 114 84 209 99 4.1 w 6 1 Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'/z(a)trl 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 5 920 4 0 69.9 110 130 130 94 10.51 118 8.3 3.4 '� 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 76.1 mm 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 T 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 w 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 1 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 108.Omm 920 3450 114.3 1 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 _ Mechanical-T cross assemblies 100 920 3450 114.3 96.80 1 146 92 239 159 ' 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with H DPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2Y50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2'BSPT clearly on order. §Vds approved for fire protection services a-PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_4 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. E Y �Z mm 920N -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 - 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 x 25 920N 3450 38.1 99 116 96 237 70 3.6 V - - 1�/4II 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 w 1/2(a)tR 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3(a)t o 920 4 0 88.9 110 140 130 92 10.51 135 10.2 8.8 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V T 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 TL 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 + 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 w 200 x 50 920 3450 69.9 138 157 159 122 316 1 114 5.3 5.3 2Y2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.7s 6.38 4.81 12.42 6.25 is.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal t Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services rt-PCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com iiictauliiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and (2)for the Style 920,920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for CvrKV Values: AP = Qz Where: AP = Qz Where: O C 2 Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(psi) V AP=Pressure Drop(Bar) Q = C x AP C =Flow Coefficient Q = K„x AP K =Flow Coefficient j Exaggerated for clarity OutletEquivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K,Values NOMINq AL • . � GROOVED '/z 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1'/< 1.660 50 48 32 42.7 5/z 6 42.9 41.1 1 Y2 1.900 53 53 40 48.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2'/2 2.875 1 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 1 1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. 1"FireLock-Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'dUI1C° 11.02_6 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Pi Run Size xt�al Outlet SizeJpe Rated Working Pressures—psi/kPa Size m Diameter S FTEW_ �O(Style920) (Style 920N) Inches/m Inches/mm *Inches mm ScPheldule UL IJLC dQ 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5Y125mm,67150mm and 87200 mm diameter pipe.The Style 931 comes with a 21h"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. X.A—c—tSUIiC® REV_O 11.02_7 rM1 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 L+tc�u�lC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 0 11.02_L �ZTISHURJOINTR) Threaded Fittings 1-01 www.shurjoint.com c&us FM 'W'. APNIINfO For Fire Protection pressure rating,listing,and approval information,visitShurjointwebsite, www.shurioint.com THREADED FITTINGS for details or contact your SHURJOINT Representative. Shurjoint offers a complete range of ductile iron Class 300 threaded fittings in sizes from %"to 2%". Material: Ductile iron ASTM A536 Gr. 65-45-12 and or Shurjoint ductile iron threaded fittings are 100% air ASTM A395 Gr. 65-45-15. tested underwater to ensure leak-free performance. Dimensions:ANSI B16.3 Class 150 except bushings and The Shurjoint ductile iron fitting series is UL listed plugs(1316.14), unions (B16.39)and companion flanges and FM approved, making them the right choice for (616.42). Please note wall thickness dimensions are fire protection and other general application services. subordinate to Shurjoint UL and FM pressure rating listings and approvals Threads:ANSI B1.20.1 NPT or ISO-7(BSPT) Finish: Black or electro-zinc plated • General Dimensions ' L These dimensions apply to all standard fittings, both straight and reducing. For center-to-face dimensions(*), - see fitting tables. Ductile Iron Class 300 threaded fittings are designed to the y. ' same dimensions as that of Class 150 malleable iron J E + H fittings.Though due to the superior strength characteristics, J ductile Iron fittings carry a much higher pressure rating. B j Laboratory tests confirm Shurjoint ductile iron fittings have T passed hydrostatic test pressures exceeding 6,000 psi/ 414 Bar,which is equal to four times the 1,500 psi/103 Bar as specified by ANSI B16.3 for 1%"—2"sizes. Size Band O.D. Band Width Thread Length(min) in in in in '/2 1.02 0.25 0.43 3/4 1.46 0.27 0.50 1 1.77 0.30 0.58 1'/4 2.15 0.34 0.67 1'/2 2.43 0.37 0.70 2 2.96 0.42 0.75 2%2 3.59 0.48 0.92 Installers who have not used DI threaded fittings before Burst pressure testing of DI threaded fittings(2") 0 should be instructed that the fittings are stronger than the pipe in most cases. In general DI threaded fittings require about a one-half turn less than cast iron fittings. Refer to the installation instructions for fiuther detail. Pressure-Temperature Ratin ANSI 11316.3&B16.14 Nom. Working Pressure • Rating @1 -G) Working Pressure Class �z —1":2000 psi/140 Bar 300 1%4"—2": 1500 psi/105 Bar 300 psi(20 Bar) 2'/2": 1000 psi/70 Bar *Proof test pressure:1.5 times the working pressure,non-shock cold water. I-01-1/6 Rev G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 811 ELBOW 900 Model . . 0' A--I size A Wt. BoxQ'ty in in Lbs PCs J '/2 1.12 0.25 240 L '/4 1.31 0.35 120 I 1 1.50 0.57 70 1'/4 1 1.75 1 0.97 1 40 1'/2 1 1.94 1 1.17 1 30 2 1 2.25 1 1.83 1 20 2'/2 2.70 3.34 1 10 MODEL 812 REDUCING ELBOW 900 ElbowModel 812 Reducing 90' B _ Size A B W. Box Q'ty in in in Lbs PCs ,. '/4X'/2 1.20 1.22 0.35 160 1 x'/2 1.26 1.36 0.46 110 1 x'/4 1.18 1.45 0.57 90 L P/4 x'/2 1.34 1.53 0.64 75 1'/4 x 1/4 1 1.45 1.62 0.68 60 1'/4 x 1 1.58 1.67 0.81 55 P/2 x'/2 1.41 1.66 0.84 45 1'/2 x'/4 1.52 1.75 0.90 45 1'h x 1 1.65 1.80 0.95 40 P/2 x P/4 1.82 1.88 1.10 35 2x3/4 1.60 1.97 1.19 1 30 2 x 1 1.73 2.02 1 1.47 25 2x11/2 2.02 2.16 1 1.61 20 2'/2 x 2 2.39 2.60 2.93 15 MODEL 813 ELBOW 450 ElbowModel 813 450 Size A Wt. Box Q'ty f in in Lbs PCs '/2 0.88 0.22 250 3/4 0.98 0.33 150 1 1.12 0.55 90 1'/4 1.29 0.84 50 P/2 1.43 0.92 35 2 1.68 1.63 18 2'/2 1 1.95 2.42 12 I-01-2/6 Rev.G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 814 TEE Model Tee - 1 Size A Wt. Box Q'ty m in Ibs PCs A '/z 1.12 0.31 150 '/a 1.31 0.48 90 1 1.50 0.81 60 1.75 1.28 35 A A� 1.94 1.72 24 01 2 2.25 2.57 12 2.70 4.44 8 MODEL 815 REDUCING TEE Model 815 Reducing Tee Size A B C W. Box in in in in Lbs PCs '/a %z 1.20 1.20 1.22 0.46 95 Yz 1 1.50 1.36 1.50 0.71 55 1 /z 1.26 1.20 1.36 0.59 80 1 '/a '/a 1.37 1.31 1.45 0.66 65 1 1.50 1.45 1.50 0.77 55 1 /z 1.26 1.26 1.36 0.64 1 65 ` '/a 1.37 1.37 1.45 0.75 60 '/z 1.34 1.26 1.53 0.79 50 1 '/a 1.45 1.37 1.62 0.88 50 1 1.58 1.50 1.67 1.01 45 1'/a 1'/a 1.75 1.67 1.75 1.25 40 '/z 1.34 1.34 1.53 0.84 45 1'/a '/a 1.45 1.45 1.62 0.99 45 1 1.58 1.58 1.67 1.12 40 '/z 1.44 1.31 1.69 0.92 40 '/a 1.50 1.37 1.75 1.01 40 1 1 1.65 1.50 1.80 1.19 30 1'/a 1.82 1.67 1.88 1.54 30 1%z 1.94 1.80 1.94 1 1.54 30 1'/ %z 1.41 1.34 1.66 1.08 40 1'A '/a 1.52 1.45 1.75 1.14 40 1 1.65 1.58 1.80 1.39 30 %z 1.41 1.41 1.66 1.10 35 1'/z '/a 1.52 1.52 1.75 1.17 35 1 1.65 1.65 1.80 1.36 30 1'/a 1.82 1.82 1.88 1.56 30 1 2 2.25 2.02 2.25 2.13 15 1'/a 2 2.25 2.10 2.25 2.22 15 %z 1.49 1.41 1.88 1.52 30 '/a 1.60 1.52 1.97 1.47 25 1'/z 1 1.73 1.65 2.02 1.63 20 2 1%z 2.02 1.94 2.16 2.09 20 2 1 2.25 2.16 2.25 2.33 15 '/z 1.49 1.49 1.88 1.56 20 1.60 1.60 1.97 1.61 20 2 1 1.73 1.73 2.02 1.80 20 P/a 1.90 1.90 2.10 2.09 20 1%z 2.02 2.02 2.16 2.24 15 2'/z 2 1 '/a 1.74 1.60 2.32 2.35 15 1-01-3/6 Rev.G 20120315 TSHURJOINT R' Threaded Fittings 1-01 www.shugant.com MODEL 815 BULLHEAD TEE Model 815 Bullhead Tee Size A B C At. Box C in in in in Lbs PCs '/4 '/4 1 1.45 1.45 1.37 0.66 65 1 1 1'/4 1.67 1.67 1.58 0.97 45 1'/z 1.80 1.80 1.65 1.15 35 1 1'/z 1.88 1.80 1.82 1.43 30 1'/4 1,/4 1%z 1.88 1 1.88 1.82 1 1.52 30 2 2.10 2.10 1.90 1.80 24 1 Yz 1'/4 2 2.16 2.10 2.02 1.94 20 1'/z 2 2.16 2.16 2.02 2.00 20 2 2 2%z 2.60 2.60 2.39 3.61 10 MODEL 816 REDUCING COUPLING Model 816 Reducing Coupling Size A Wrench Size At. Box in in in Lbs PCs : s '/4 x'/z 1.63 1'/4 0.37 150 1 x Yz 1.69 1 1/4 0.37 140 } 1 x'/4 1.37 1'/z 0.48 120 1'/4 x 3/4 2.06 1-'/z 0.59 80 1'/4 x 1 2.06 0.66 60 lYzxl 2.31 0.84 50 P/z x P/4 2.31 0.92 45 2 x 1 2.81 1.23 35 2 x 1'/4 2.81 1.28 30 2 x 1'/z 2.81 1.66 30 2'/z x 2 3.25 - 2.24 18 MODEL 817 CROSS B B--I . • - � size A B W. Box Q'ty A in in in Lbs PCs 1 1/2 1.12 1.12 0.48 90 1- 3/4 1.31 1.31 0.77 60 A 1 1.50 1.50 0.95 45 1'/4 1.75 1.75 1.43 25 1%z 1.94 1 1.94 1 1.87 1 20 2 2.25 2.25 2.86 10 A�A Model 817 Reducing Cross Size A B W. Box Qty in in in Lbs PCs 1'/xl'/a 1A 1.67 1.58 1.25 30 1'/A1 YAW 1.80 1.65 1.47 24 2x2xl xl 2.02 1.73 1.94 16 I-014/6 Rev G 20120315 TSHURJOINTR Th - " ' - ' Fittings 1-01 www.shugant.com MODEL 818 STRAIGHT COUPLING ,- Model 818 Straight Coupling Size A Wrench Size W. Box Q'ty i in in in Lbs PCs + I A /2 1.38 1'8 0.18 360 i I '/4 1.61 1%" 0.26 200 1 1.77 111/16" 0.42 110 1'/4 2.00 2" 0.57 75 1'/z 1 2.20 1 2'/4" 1 0.77 1 60 2 1 2.60 1 23/4" 1 1.17 1 30 2'/2 3.00 3%" 2.11 18 MODEL 820 CAP Model i Cap r size A VV1. Box Q'ty in m in Lbs Ya 0.89 0.14 500 I. '/4 1.00 0.20 300 1 1.18 0.33 180 1'/4 1.32 0.46 110 1'/z 1.38 1 0.57 80 2 1.48 1 0.88 1 45 2Y2 1.77 1.54 25 MODEL 825 EXTENSION PIECE Model Size A Wt. Box Q'ty in in Lbs PCs '/2 x 1'/zL 1.50 0.18 300 '/2 x 2L 2.00 0.22 250 t".., 3/4x1Y2L 1.50 0.22 250 '� 6 '/4 x 2L 2.00 0.26 200 f: AA MODEL 831 LONG STREET ELBOW 900 ElbowModel 831 Long Street • i ' all% size A B W. Box Q'ty in in in Lbs PCs i 1 x'/2M 1.50 3.00 0.66 80 g 1 x 1M 1.50 3.00 0.81 60 I-01-5/6 Rev.G 20120315 TSHURJOINTR Threaded Fittings 1-01 www.shugant.com MODEL 832 LONG STREET TEE Model 832 Long Street Tee C size A B C Wt I Box Q'ty in in in in Lbs Pes 1 x'/2XIM 1.50 1.40 3.00 0.91 50 -t-- IX1x1M 1.50 1.50 3.00 1.03 45 MODEL 827 HEX BUSHING Model 827 Hex Bushing Size A Wt. Box Q'ty in in Lbs PCs A I X'/2 1.06 0.20 280 1 x3/4 1.06 0.18 280 qW, 1'/4 X I 1.18 0.29 150 1'/2 x 1 1.26 0.53 100 Ph x P/4 1 1.26 0.37 100 2 x 1 1 1.34 0.75 80 2 x 1'/4 1 1.34 0.75 80 2 x 1'/2 1 1.34 0.64 80 MODEL 819 PLUG Model 819 Plug size A Wt. BoxQty in in Lbs PCs '/2 0.93 0.09 500 3/4 1.13 0.18 300 1 1.25 0.25 200 A 1'/4 1.36 0.42 110 1 Y2 1.45 0.59 80 2 1 1.50 1 0.95 1 45 General Notes: • Pressure ratings listed are CWP(cold water pressure)or rnaximum Aurking pressure widen the service temperature range ofthe gasket used in the coupling.This rating may occasionally differ from maximum NNurking pressures listed and/or approved by UT,ULC,and/or FM as testing conditions and test pipes differ.For additional information contact Shurjoint.. • NVhximum wutidng pressures and end loads listed are total of internal and extemal pressures and loads based on Sch. 10 steel pipe with roll grooves toANSFAWWAC606-07 specifications.For information on other pipe schedules contact Shurjoint.. • For one time field test only the maximum joint vwrking pressure may be increased 1'/2 times the figures shown. • Warning:Piping systems must always be depressurized and drained before attempting disassembly and or removal ofany components. • Shurjoint reserves the right to change specifications,designs and or standard equipment without notice and without incurring any obligations. Job Name: System No. Location: Contractor: Approved: Date: Engineer: Approved: Date: Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,please contact Shurjoint Technical Service.Shurjoint reserves the right to change or modify product design, construction, specifications,or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. I-01-6/6 Rev.G20120315 i FIRE SPRINKLER PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: F] New Installation [] System Modification [] Phased Installation Property Address. 18520 67th Ave NE Suite No.: Project Valuation: 149,900 Lot#: Parcel ID No.: 31052200102000 Preferred Contact: ❑ Owner ❑Applicant ❑ Contractor Project Description: Burns to start at flange 12" AFF inside of riser room to provide code compliant NFPA13 system Owner Name: Mina Properties VII, LLC Phone No.: Email Address: Cell No.: Mailing Address: 1418 MarketSt City: Kirkland State: WA zip: 98033 Applicant Name: Audra Williams Phone No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: 425-223-6464 Mailing Address: PO Box 1110 City:Granite Falls State: WA Zip: 98252 Contractor Name: Burns Fire Protection Systems, Inc. Office No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: 425-223-6464 Mailing Address: PO Box 1110 City: Granite Falls State: WA zip: 98252 L&I Contractor License Number: BURNSFP841 DU Expiration Date: 12-31-2023 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: 0 Complete and Scaled Plans I] Hydraulic Calculations I] Equipment Specifications for Each Fire Sprinkler Permit Application 0 Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.00 + 1 $ 1 = $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ✓❑ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = 433 $625.00 + 1 $100 = $ 725.00 Hydraulically Designed Systems Yes 0 / No ❑ Yes = Permit Fee x 2 $ 1450.00 PERMIT FEE SUBTOTAL $ 2175.00 ❑ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I - new or existing x $150.00 = $ Class II - new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ 2175.00 PLAN REVIEW FEE $ 1918.24 Processing/Technology Fee $25.00 TOTAL $ 4093.24 I hereby certify that I am the ❑ Owner, ✓❑Applicant, ❑ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 Seismic Brace Report p . / Ack,Engineered Solutions Project Name Seattle Galvanizing Company APPROVAL STAMP MI Date 09/05/2023 ❑ Approved Address 18520 67th Ave NE Arlington, WA 98223 ❑ Approved as Noted - -- ❑ Not Approved WASHINGTON STATE ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , Remarks: David Yates 2605.0898-C Level , ' Burns Fire Protection Systems,Inc. I=F 2801bU 9/6/23 Expires: ; Signxture Date 12/31/23 Standard NFPA 13-2019 ................................ BRACE SUMMARY Drawing Seismic Design Brace Name Structure Brace Description Fastener Attachments Reference Load Lateral A FP2 450 Ibf. Horizontal Beam Flange Lateral Orientation 60'-90' 1 NPS Sch AF778 40 AF700-1/2" AF035-4 NPS x 1 NPS Longitudinal B FP2 157 IV. Horizontal Beam Flange Longitudinal Orientation 60°-90° 1 AF778 NPS Sch 40 AF700-1/2" AF730-4 NPS NOTE:Per NFPA 13-2019,all load capacities listed for fasteners installed in cracked concrete have been reduced based on the prying factors listed for ASC's swivel attachments.Prying factors for NFPA fastener orientations"A"through "I"may be found in ASC's individual product submittal at asc-es.com NFPA 13-2016 Product loads incorporate a minimum safety factor of 1.5.NFPA 13-2019 FM Product loads have been reduced to include a safety factor of 2.2 unless noted in the applicable product submittal. The products specified within this report are limited to the capability of the sway brace assembly alone to resist the calculated seismic force resulting from user input. Point loads applied to structural elements as a result of seismic forces are not evaluated by the software.The seismic load rating of the fastener attached to a structural element is determined by one of the following:NFPA 13,UL listing,FM Global approval,or other empirical testing. The review of the of the structural element(s)as a whole and/or the entire structure and its ability to resist the seismic load(s)is beyond the scope of these seismic calculations. ASC MAKES NO WARRANTIES,EXPRESS,IMPLIED,STATUTORY,OR OTHERWISE, WITH RESPECT TO THE SOFTWARE OR THE SEISMIC CALCULATIONS,AND ASC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 1 LATERAL A - SEISMIC BRACE CALCULATIONS Seismic Project Braces to Crane support beams Brace Name Lateral A Standard NFPA 13-2019 Drawing Reference FP2 Brace Type Lateral Approval Agency UL Listed STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS Structure I-Beam/Joist Model Size Load Rating Substrate Horizontal Beam Flange Structural Att. AF778 N/A 1,385 Ibf. Thickness 0.250 in. Swivel Att. AF700 1/2" 1,632 Ibf. Load Orientation Parallel to Beam Pipe Att. AF035 4 NPS x 1 NPS 1,632 Ibf. BRACE INFORMATION See Appendix A for alternate seismic brace attachments. Brace Member 1 NPS Sch 40 All seismic brace attachments manufactured byASC Engineered Solutions. Brace Length Max 7 ft 0 in Brace Angle 600 - 900 structure: Beam(By Others) Least Radius of Gyration 0.421 in. Fig.AF77s 1/r Ratio Max 200 01 Fig.AF700 Max Horizontal Load 1,604 Ibf. FASTENER INFORMATION Pipe Schedule 40 Service Fastener Name N/A Brace Pipe Fig.AF035 Net Vertical Reaction Forces do not need to be addressed per NFPA 13-2019. SPRINKLER SYSTEM LOAD CALCULATION (Fpw = CP*WP) CP = 0.602 AW Qty Line Description Pipe Diameter/Type Length Weight per ft Weight 1 Main Braced Pipe 4 NPS Eddy Flow 19.00 ft. 11.29 lb/ft. 214.51 lb. 2 Branch 1 Segment A 1 1/2 NPS Eddy Flow 76.00 ft. 2.86 lb/ft. 217.36 lb. Weakest Main Size Spacing Max Fpw Total System Weight 649.23 lb. 4 NPS Eddy Flow 20 ft. 1,544 Ibf. System Design Weight (WP) 747.00 lb. Horizontal Seismic Load (Fpw) 450 Ibf. 2 LONGITUDINAL B - SEISMIC BRACE CALCULATIONS Seismic Project Braces to Crane support beams Brace Name Longitudinal B Standard NFPA 13-2019 Drawing Reference FP2 Brace Type Longitudinal Approval Agency UL Listed STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS Structure I-Beam/Joist Model Size Load Rating Substrate Horizontal Beam Flange Structural Att. AF778 N/A 1,385 Ibf. Thickness 0.250 in. Swivel Att. AF700 1/2" 1,632 Ibf. Load Orientation Perpendicular to Beam Pipe Att. AF730 4 NPS 1,632 Ibf. BRACE INFORMATION See Appendix A for alternate seismic brace attachments. Brace Member 1 NPS Sch 40 All seismic brace attachments manufactured byASC Engineered Solutions. Brace Length Max 7 ft 0 in Brace Angle 60' -90' _ Fig.AF778 Structure: Least Radius of Gyration 0.421 In. Beam (By Others) I/r Ratio Max 200 Fig.AF7°° Max Horizontal Load 1,604 Ibf. FASTENER INFORMATION Schedule 40 Fig.AF730 Brace Pipe Fastener Name N/A Service Pipe Net Vertical Reaction Forces do not need to be addressed per NFPA 13-2019. SPRINKLER SYSTEM LOAD CALCULATION (Fpw = Cp*Wp) Cp = 0.602 ;11&. M Qty Line Description Pipe Diameter/Type Length Weight per ft Weight 1 Main Braced Pipe 4 NPS Eddy Flow 20.00 ft. 11.29 Ib/ft. 225.80 lb. Total System Weight 225.80 lb. System Design Weight (Wp) 260.00 lb. Horizontal Seismic Load (Fpw) 157 Ibf. 3 Appendix A - Alternate Seismic Brace Attachments LATERAL A Structural Attachment Structural Structural Attach. Swivel Pipe Attachment Attach. Size Capacity AF778 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. AF735 4 NPS x 1 NPS 1,632 Ibf. AF778 1,385 Ibf. AF076 1/2" 11,515 Ibf. AF730 4 NPS 11,632 Ibf. AF720 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. AF720 1,385 Ibf. AF700 1/2" 1,632 Ibf. - AF720 1,385 Ibf. AF076 1/2" 1,515 Ibf. - AF087 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF087 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF087 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 649 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF086 649 Ibf. AF076 1/2" 11,515 Ibf. - AF086 649 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 649 Ibf. AF700 1/2" 11,632 Ibf. - AF086 649 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - LONGITUDINAL B Structural Attachment Structural Structural Attach. Capacity Swivel Pipe Attachment Attach. Size AF778 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - AF778 1,385 Ibf. AF076 1/2" 11,515 Ibf. - AF720 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - AF720 1,385 Ibf. AF700 1/2" 1,632 Ibf. - AF720 1,385 Ibf. AF076 1/2" 1,515 Ibf. - AF087 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF087 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF087 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF086 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF086 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 1,186 Ibf. AF700 1/2" 11,632 Ibf. - AF086 1,186 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. 4 Appendix B - Enlarged Images LATERAL A Structure: Beam (By Others) Fig. AF77S 0 -- .J Fig. AF700 Schedule 40 Service Brace Pipe Pipe Fig. AF035 LONGITUDINAL B Fig. AF778 Structure. Beam (By Others) �\ Q `J Fig. AF700 Fig. AF730 Schedule 40 Brace Pipe \� Service Pipe 5 Appendix C - Cp Calculations BRACE CALCULATION DATA Brace Name Brace Ref Method CP SS Site Fa SDS Z H Lateral A FP2 A 0.602 1.280 Longitudinal B FP2 A 0.602 1.280 CALCULATION METHODS A CP calculated per NFPA 13-2019 Table 18.5.9.3 B CP entered by user C CP calculated per ASCE/SEI 7-16 per NFPA 13-2019 Section 18.5.9.4 Notes for Calculation Method C Per NFPA 13-2019, the following values are always assumed for aP,RP,and IP: aP RP IP 2.5 4.5 1.5 LEGEND EQUATIONS FPW Seismic Horizontal Design Force Fpu, = CpWp CP Seismic Coefficient per NFPA SS Short Period MCEr Spectral Response Acceleration Where:C 0.4RDs S 1 p Z * Hl Fa Site Coefficient. See Tables Below. p = 0.7 ` J P (1 +2 SpS Short Period Spectral Acceleration aP Component Amplification Factor. Taken as 2.5 for Fire Sprinkler Applications Where:SDs — 2�3 FaSs RP Component Response Modification Factor.Taken as 4.5 for Fire Sprinkler Applications IP Component Importance Factor.Taken as 1.5 for Fire Sprinkler Applications Cp,n = 0.7* 1.6SDSIp WP Component Operating Weight.Taken as the weight of the Fire Sprinkler System in the ZOI plus 15% Z Height in the structure where the component attaches to the structure. Height is Cp min = 0.7* 0.3SDSIp relative to the base of the structure and shall not be taken as less than 0 and shall not be larger than "H". H Average roof height of the structure relative to the base 6 SITE COEFFICIENT, FA PER ASCE/SEI 7-16 SS <_ 0.25 SS = 0.5 SS = 0.75 SS = 1 SS = 1.25 SS > 1.5 A 0.8 0.8 0.8 0.8 0.8 0.8 B 0.9 0.9 0.9 0.9 0.9 0.9 C 1.3 1.3 1.2 1.2 1.2 1.2 D 1.6 1.4 1.2 1.1 1 1 E 2.4 1.7 1.3 1.2 1.2 1.2 Use straight-line interpolation for intermediate values of S, SITE CLASSIFICATION PER ASCE/SEI 7-16 Site Class Ground Structure A Hard Rock B Rock C Very Dense Soil and Soft Rock D Stiff Soil E Soft Clay Soil 1' H i Z t GROUND BEFORE A SEISMIC EVENT DURING A SEISMIC EVENT (Exaggerated) 7 Appendix D - Bill of Materials Project Name Seattle Galvanizing Company Code Requirements NFPA 13-2019 Last Updated September 5, 2023 QUANTITY FIGURE NUMBER PRODUCT DESCRIPTION 0 Fastener 0 AF778 AF778 Universal Structural Brace Attachment AF778 0 AF700 1/2"AF700 Universal Swivel Attachment AF700-1/2" AF035 4 NIPS AF035 Model K Brace Clamp AF035-4 NIPS x 1 NIPS AF730 4 NIPS AF730 Longitudinal&Lateral Seismic Clamp AF730-4 NIPS 8 AFCONO Seismic Braces `11111�:p Engineered Solutions Universal Structural Brace Attachment Fig.AF778 Material Specifications Size Range: Flange Thickness: 1/8"to 1/4"thick Material Ductile Iron Casting with Carbon Steel Hardware A Finish H ❑ Plain ❑ ELectro-Galvanized per ASTM B633 Service A seismic structural attachment designed to NOW 1/2"Mounting Bolt attach to steel I-beams,flanges,and joists.The AF778 rigidly braces piping systems subjected to L horizontal and vertical seismic loads. J Approvals cULus Listed(ANSI/UL 203a),FM Approved(FM W 1950-13),&OSHPD(OPM-0351-13).Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. osr7pd cL us FM Features OPM-0351-13 LISTED APPROVED Shear Off Bolt x 2 The set screw provides a visual indication that proper installation has been achieved FIG.AF778 Dimensions and Weight May be installed anywhere a Fig 92 standard throat beam clamp may be installed Mounting Bolt A B L W H Weight In./mm In./mm In./mm In./mm In./mm Ibs/kg Ordering 16" 0.75 0.75 4.13 2.75 2.25 2.26 Specify figure number,finish,and description. (M12) 19.1 19.1 104.8 69.9 57.2 1.03 Installation Instructions AFCON.1 An ASC Engineered Solution Place the AF778 on a horizontal orvertical 3 Mount the AF700,AF771,orAF076 to the steel flange. 1/2"mounting bolt.The mounting bolt shall be installed wrench tight(typicaLLy finger 2 Hand tighten the set screws until they tight plus'/4 to 1/2 turns). contact the flange.Continue to torque the Notes: When installed with the AF700,AF771,or set screws until the heads break off. AF076,the Lowest Load rating at angle shall control the load rating of the assembly. PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-05.21 page 1 SS—SUB—AF778—v02 20230705 AFCONO Seismic Braces Engineered Solutions Universal Structural Brace Attachment Fig.AF778 FIG.AF778 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-90° Listed In./(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) Lbf/kN Horizontal Steel Flange and Parallel to Flange 0.1875-0.750 800 1131 1385 1600 Vertical Steel Flange Perpendicular to Flange (4.76-19.05) (3.56) (5.03) (6.16) (7.12) 1) Listed for installation with Fig.AF700,AF771,and AF076 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. Horizontal Steel Flange 4)Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. Seismic Load Parallel to Flange FIG.AF778 cULus Listing per UL 203a(ASD)for NFPA 13-2016 Editions or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 73.The 2076 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition.The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 203A,Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping,based upon a minimum safety factor of 1.5 in accordance with the earlier editions of NFPA 73.The load ratings based upon the 2076 or earlier editions of NFPA 13 should only be used where approved by the Authority HavingJurisdiction(AHJ). Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-90° Listed nd(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) LVAN 0.1875-0.249 500 707 865 1000 Horizontal Steel Flange (4.76-6.32) (2.22) (3.15) (3.85) (4.45) Seismic Load Perpendicularto Flange Horizontal Steel Flange and Parallel to Flange 0.250-0.499 800 1131 1385 1600 Vertical Steel Flange Perpendicular to Flange (6.35-12.67) (3.56) (5.03) (6.16) (7.12) OO OO 0.500-0.750 1007 1425 1744 2015 (12.70-19.05) (4.48) (6.34) (7.76) (8.96) Q 1) Listed for installation with Fig.AF700&AF771 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2016 Table 9.3.5.2.3. Oo 4)Minimum safety factor oft.5in accordance with NFPA13-2016 Section A.9.3.5.2.3. FIG.AF778 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-74° 75°-90° Vertical Steel Flange In./(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) Lbf/kN Seismic Load Parallel to Flange Parallel to Flange 1280 1840 2210 2470 Horizontal Steel Flange (5.69) (8.18) (9.83) (10.99) Perpendicular to Flange 1570 1490 1040 1150 0.125-0.750 (6.98) (6.63) (4.63) (5.12) (3.18-19.05) 870 1440 1230 1360 Parallel to Flange O Vertical Steel Flange (3.87) (6.41) (5.47) (6.05) Perpendicular to Flange 1038 2260 2490 2750 (4.58) (10.05) (11.08) (12.23) 1) Listed for installation with Fig.AF700&AF771 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA13-2019 Table 18.5.2.3. 4) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA13-2019 Section A.18.5.2.3,multiply load ratings by a factor of 0.68. Vertical Steel Flange 5) To convert toLRFD Load Ratings,ASD Load Ratings may bemuLtipliedbya factor of1.5 Seismic Load PerpendiculartoFlange Notes: ASC Engineered SolutionsTm brand bracing components are designed to be compatible ONLYwith other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly.Updated UL Listing information may be viewed at www.uL.com and updated FM approval information may be viewed ® © © at www.approvaLguide.com. Disclaimer: asc-es.com ASC Engineered SolutionsTm does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not Building connections that last' manufactured or sold by ASC.In no event shall ASC be liable for any incidental,direct,consequential,special or indirect damages or Lost profits where non-ASC bracing components have been,or are used. Sells Brace®Seismic Fire Protection Design Tool.may be accessed at www.seisbrace.com SS-03.22 page 2 SS-SUB-AF778-v0220230705 AFCONO Seismic Braces Engineered Solutions Universal Swivel Attachment Fig.AF700 Material Specifications Size Range Brace Member:See Table Anchors:1h"-1/4"(M12—M18) Material Ductile Iron with Carbon Steel Hardware Finish ❑ Plain o, ❑ ELectro-Galvanized perASTM B633 r Service A seismic swivel attachment designed to connect a brace member to the building structure or to a seismic structural attachment.The AF700 rigidly € r braces piping systems subjected to horizontal and vertical seismic Loads. Approvals cLJLus Listed(ANSI/UL 203a)),FM Approved(FM c uL us Fm 1950-13),&FM Tested(FM 1950-16).FM Tested LISTED APPROVED (ANSI/FM 1950-16).Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Features • The set screw provides a visual indication that proper installation has been achieved OEliminates brace member eccentricity by T—Ac concentrically Loading T'and 11/4"brace pipes + Ordering Specify figure number,fastener size,finish and D description. AX Y Disclaimer: L ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shaLL ASC be liable FIG.AF700 Dimensions and Weight for any incidental,direct,consequential,special or indirect A B C D L X Y Weight damages or Lost profits where non-ASC bracing components have been,or are used. In./mm In./mm In./mm In./mm In./mm In./mm In./mm Ibs/kgs Seis Brace'Seismic Fire Protection Design Tool maybe 1.40 1.983 1.400 1.280 6.40 2.80 1.91 2.25 accessed at www.seisbrace.com 35.56 50.37 35.56 32.51 162.6 71.1 48.5 1.02 Notes: ASC Engineered SolutionsTI brand bracing components are designed to be compatible ONLY with other ���0� ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL Listing information may be viewed at www.ut.com and updated FM approval information may be viewed at www.approvaLguide.com. — An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: submittal Date: September 5,2023 Notes 1: Notes 2: SS-05.21 page 1 SS-SUB-AF700-vO2 20220408 AFCONO Seismic Braces Engineered Solutions Universal Swivel Attachment Fig.AF700 FIG.AF700 cULus Listing per ANSIML 203a(ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle VA4 30"-44" 45°-59° 60°-90' Listed 1 2" 'h"-W 942lbf 1333Ibf 1632Ibf 1885lbf Sch 40 Pipe(DN25-DN50) (M12-M18) (4.19 kN) (5.93 kN) (7.26 kN) (8.38 kN) 1) Load ratings may apply to NPFA 13 fastener orientations A,B,C,D,E,F,G,H,or I. 2) Brace Angles are determined from Vertical. 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) See table below for listed brace members. 5) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. NFPA 13 Orientations A,B,or C FIG.AF700 FM Approved(Listing)per FM 1950-13(ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle 30°-44° 45°-59° 60°-74' 74'-90° 1`2" Y2"-3/4' 1780lbf 2510IV 3080lbf 3440lbf O Sch 40 Pipe (M12-M18) (7.92 kN) (11.17 kN) (13.70 kN) (15.30 kN) (DN25-DN50) 1) Load ratings may apply to NPFA 13 fastener orientations A,B,C,D,E,F,G,H,or I. 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 TabLe 18.5.2.3. 4) See table below for listed brace members. 5) Minimum safety factor oft.5in accordance with NFPA13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply Load ratings by a factor of 0.68. 6)To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. NFPA13 Orientations D,E,or F FIG.AF700 FM Listed,Approved&Tested Brace Members Brace Member Brace Size Standard(or Equivalent) UL FM Sch.40 NPS Pipe 1",11ra",1 Y2",2" ASTM A53,Al06,A135,or A795 ✓ ✓ O DN25 KS S 3562 Sch.40 Metric Pipe ✓ ✓ DN32 EN10255H ✓ DN40 GB/T 3091 ✓ Metric Pipe DN50 JIS G3454 ✓ FIG AF700 Horizontal Prying Factors(Pr)Per NFPA 13:Angles(Deg) Fastener Orientation A B c D E F G H I Brace Angle 30°-44° 45°-59° 60°-90° 30°-44° 45°-59° 60°-90° 30°-44° 45°-59° 60°-90° NFPA 13 Orientations G, H,or I AF700 2.55 1.09 0.91 1.41 1.45 2.00 1.83 1.29 1.06 AF700 w/Metal Deck' 2.55 1.09 1.14 - - - - - - AF700 w/Metal Deck 2.75 1.11 1.14 - - - - - - 1) Prying factors reflect the basepLate`B"dimension overhanging the edge of the metal deck.Used for DeWaLt [moo anchor Loads. 2) Prying factors reflect the baseplate"A"or"B"dimension overhanging the edge of the metal deck.Used for asc-es.com NFPA&HiLti anchor Loads. .I 3) Prying Factors calculated in accordance with NFPA13-2019 Section A.18.5.12.2. BUILding connections that lat Last' SS-05.21 page 2 SS-SUB-AF700-v0220220408 AFCONO Seismic Braces MC. P / Engineered Solutions Universal Swivel Attachment Fig.AF700 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly up to the fastener or the related seismic structural attachment and connect through the mounting hole. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the range specified. Notes:The cross bolt should be hand tight.Forvisual inspection,at least one thread should be exposed. Method 2 - Connection to Structure First Connect the AF700 to the fastener or the related seismic structural attachment. 2 Tighten per the fastener or structural attachment specifications. 3 Slide the brace member over the lowerjaw until it contacts the back wall. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 5 Rotate the brace member until the brace angle is within the specified range. Notes:The cross bolt should be hand tight.Forvisual inspection,at least one thread should be exposed.. Structural Attachments,Anchors,&Fasteners Listed,Approved,&Tested with the AF700 Structural Attachment Structure AF085 Steel Joist(Top Chord) AF086 Horizontal Steel Flange(I-Beam Bottom Flange) AF772 Horizontal Steel Flange(I-Beam Bottom Flange) Horizontal Steel Flange(I-Beam Top or Bottom Flange) AF778 C-Channel(Top or Bottom Flange) Vertical Flange of a Joist(Top Chord) AF779 All Structures with the Applicable Approved Anchor or Fastener DeWalt Cracked Concrete Power-Stud®+SD1 Cracked Concrete Filled Metal Deck DeWalt Cracked Concrete Power-Stud®+SD2 Cracked Concrete Filled Metal Deck DeWalt Cracked Concrete Wood-Knocker®I I+ DeWalt Bang-It°+ Cracked Concrete Filled Metal Deck DeWalt DDI+' Cracked Concrete Filled Metal Deck Cracked Concrete [moo Anchors&Fasteners Cracked Concrete Filled Metal Deck Per NFPA 13 Steel asc-es.com Wood Saw Lumber or Glue-Laminated Timbers Building connections that last" SS-05.21 page 3 SS-SUB-AF700-4220220408 AFCONO Seismic Braces kttp Engineered Solutions Model K Lateral Sway Brace Fig.AF035 Material Specifications Size Range: Service Pipe Size:T'-12" Brace Member:T'-2" Material r Ductile Iron Casting with Carbon Steel Strap and Hardware Finish ❑ Plain ❑ Electro-Galvanized Service ®r' A seismic lateral brace designed to connect a brace member to the service pipe.The AF035 rigidly braces steel and CPVC piping systems subjected to horizontal and vertical seismic Loads. C U� US FM Approvals LISTED APPROVED cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).Complies with NFPA 13,ASCE 7, IBC,&MSS SP-127 bracing requirements. Features • The set screw provides a visual indication that proper installation has been achieved • Rounded edge design eliminates potential for abrasion of CPVC pipe Patents No.7,516,922,No.7,523,895 t ° Ordering O Specify figure number,service pipe size,brace size,finish,and description. o 1"(DN25)to 3"(DN80)Service Pipe 4"(DN100)to 12"Service Pipe AFCON® An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-04.21 page 1 SS-SUB-AF035-v03 20220408 / • © Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035:Weight Per Size Brace Member Size Service Pipe Size 1"(DN25) 1%"(DN32) 1%"(DN40) 2"(DN50) 1 1.60lbs 1.80lbs 2.00lbs 2.28lbs (DN25) 1'�4" 1.68 lbs 1.88 lbs 2.08 lbs 2.36 lbs (DN32) 1/z 1.64 lbs 1.84 lbs 2.04 lbs 2.32 lbs (DN40) 2 1.88lbs 2.08lbs 2.28lbs 2.56lbs (DN50) 21h" 1.90lbs 2.10lbs 2.30lbs 2.58lbs DN65 2.00lbs 2.20lbs 2.40lbs 2.68lbs 3 2.10lbs 2.30lbs 2.50lbs 2.78lbs (DN80) 4 2.18lbs 3.38lbs 3.58lbs 3.76lbs (DN100) 5 3.40lbs 3.60lbs 3.80lbs 4.08lbs (DN125) DN150 3.80lbs 4.00lbs 4.20lbs 4.48lbs 6" 3.90lbs 4.10lbs 4.30lbs 4.58lbs DN200 4.70lbs 4.90lbs 5.10lbs 5.38lbs 8" 4.80lbs 5.00lbs 5.20lbs 5.48lbs 10" 5.60lbs 5.80lbs 6.00lbs 6.28lbs 12" 6.16lbs 6.36lbs 6.56lbs 6.84lbs ®©o asc-es.com Building connections that last" SS-04.21 page 2 SS-SUB-AF035-4320220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 cULus Listing per ANSI/UL 203a(ASD) Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service Pipe Size 30°-44° 45°-59° 60°-90° Listed Pipe Pipe IVAN VAN YAN VAN V,Aa Sch.10 Mega-Thread 1" Sch.40 MLT/GL (DN25) CPVC Eddy Thread Metric Pipe EZ-Thread Mega-Flow Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Mega-Flow Lateral Application Sch.10 MLT/GL 11/2 Sch.40 Mega-Thread (DN40) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 625 884 1082 1250 2.78 3.93 4.81 5.56 Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega-Thread (DN50) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Sch.10 Mega-Flow 21/2" Sch.40 Eddy Flow CPVC Fire-Flo DN65 Metric Pipe - Lateral Appllcatlon Sch.10 Mega Flow 3" Sch. Eddy Flow (DN80) CPVCC Fire-Flo O Metric Pipe 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 5„ Sch.10 O (DN125) Sch.40 - Metric Pipe DN150 Metric Pipe - 942 1333 1632 1885 Sch.10 4.19 5.93 7.26 8.38 6 Sch.40 Mega-Flow 0 DN200 Metric Pipe - 8„ 0.188"wall _ Sch.40 0.1ch.wall Riser Application 10" 0.188" 12" 0.188"wall _ 1125 1591 1948 2250 Sch.40 5.00 7.08 8.67 10.01 1) Brace Angles are determined from Vertical. 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) See table below for UL listed specialty pipes&UL Listed metric service pipes. 5) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for Listed asc-es.com brace members. Building connections that last" 6) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. SS-04.21 page 3 SS-SUB-AF035-v0320220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 cULus Listing Per UL 203a(ASD)For NFPA 13-2016 Editions Or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 13.The 2076 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition.The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 2O3A,Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping based upon a minimum safety factor of 7.5 in accordance with the earlier editions of NFPA 73. The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority Having Jurisdiction(AHJ). Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Pipe Pipe Ibf/kN Ibf/kN Ibf/kN Ibf/kN Sch.10 Mega-Thread 1 Sch 40 MLT/GL (DN25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow Lateral Application Sch.10 MLT/GL 1° Sch 40 Mega-Thread (DN32) Metric Pipe Eddy Flow Eddy Thread EZ-Thread Mega-Flow MLT/GL 11/2'. Sch.10 Mega-Thread (DN40) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread EThread Fire-Flo Latera[App llcation Fire-Flo 1382 1955 2393 2765 Sch.10 Mega-Flow 6.15 8.70 10.65 1 b.. 21h" Sch.40 Eddy Flow Metric Pipe Fire-Flo O DN65 Metric Pipe - 3" Sch.10 Mega-Flow (DN80) Sch.40 Eddy Flow Metric Pipe Fire-Flo 4" Sch.10 Mega-Flow O (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 5" Sch.10 (DN125) Sch.40 - Metric Pipe 0 DN150 Metric Pipe - 6„ Sch.10 Sch.40 Mega Flow DN200 Metric Pipe - Riser Application 8" 0.188"Wall _ Sch.40 101, 0.188"Wall _ Sch.40 12" 0.188"Wall _ 1870 2644 3238 3740 Sch.40 8.32 11.77 14.40 16.64 1) Brace Angles are determined from Vertical. [moo 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2016 Section A.93.5.23. asc-es.com 4) See table below for UL Listed specialty pipes&UL Listed metric service pipes. 5) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for Listed brace members. BUILdIng connections that Last" 6) Minimum safety factor of 2.2 in accordance with NFPA 13-2016 Section A.9.3.5.23. SS-03.22 page 4 SS-SUB-AF035-v03 20220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 FM Approved(Listing)per FM 1950-13(ASD) Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service VAO Pipe Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Sch.10 Mega-Thread 1 Sch.40 MLT/GL (DN25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow 1660 2350 2880 3210 MLT/GL 7.38 10.45 12.81 14.28 114° Sch. Mega-Thread (DN32) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Lateral Application Mega-Flow MLT/GL 11r2 Sch.10 Mega-Thread (DN40) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 1540 2170 2660 2970 Mega-Flow 6.85 9.65 11.83 13.21 MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Sch.10 Mega-Flow 2h Sch.40 Eddy Flow Fire-Flo Lateral Application DN65 Metric Pipe - 1270 1790 2200 2450 5.65 7.96 9.79 10.90 O 3„ Sch.10 Mega-Flow (DN80) Sch.40 Eddy Flow Metric Pipe Fire-Flo 4" Sch.10 Mega-Flow O 1020 1450 1770 1980 (DN100) Sch.40 Eddy Flow 4.54 6.45 7.87 8.81 Metric Pipe Fire-Flo 5„ Sch.10 (DN125) Sch.40 - Metric Pipe O 860 1220 1490 1660 DN150 Metric Pipe - 3.83 5.43 6.63 7.38 6" Sch.10 Mega-Flow Sch.40 Riser Application DN200 Metric Pipe - 540 770 950 1060 8„ 0.188"Wall 2.40 3.43 4.23 4.72 Sch.40 1) Brace Angles are determined from Vertical. 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© 3) See table below for FM listed specialty pipes&FM Listed metric service pipes. 4) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for listed brace members. 5) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings asc-es.com above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply Load ratings by a factor of 0.68. 5)To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. BUILding connections that Last" SS-04.21 page 5 SS-SUB-AF035-v0320220408 AFCONO Seismic Braces xcwk, / Engineered Solutions Model K Lateral Sway Brace Fig.AF035 Place the AF035 over the service pipe to be braced. Z Insert the brace member through the cast hoop ends. The end of the brace pipe shall extend at least 1"(25.4 mm)past the cast hoop ends. 3 Hand tighten the set screws until they contact the brace member. Continue to torque the set screws until the heads bottom out on the cast hoop ends. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the specified range. Notes:The brace member may be installed above or below the service pipe. 1"Min. ❑ ❑ Set Screw Installation 10i FIG.AF035 cULus Listed&FM Approved Brace Members Brace Member Brace Size Standard(or Equivalent) UL FM Sch.40 NPS Pipe 1",1 Y4",1'h",2" ASTM A53,Al06,Al35,or A795 ✓ ✓ KS S 3562 ✓ ✓ Sch.40 Metric Pipe DN25 EN10255H ✓ DN32 DN40 GB/T 3091 ✓ DN50 Metric Pipe JIS G3454 ✓ FIG.AF035 cULus Listed&FM Approved Metric Service Pipes Service Pipe Standard(or Equivalent) Service Pipe Size UL FM KS D 3507 V ✓ KS D 3537 DN25 KS D 3562 DN32 ✓ ✓ Sch.40 DN40 GB/T 3091 DN50 ✓ GB/T 3092 DN65 JIS G3452 DN80 ✓ DN100 EN 10255M DN125 ✓ DN150 EN 10255H DN200 ✓ Notes: ASC Engineered Solutions""brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly.Updated UL Listing information may ®© be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. Disclaimer: asc-es.com ASC Engineered Solutions does not provide any warranties and specifically disclaims any Liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not Buildin6 connections that last' manufactured or sold by ASC.In no event shall ASC be Liable for any incidental,direct,consequential,special or indirect b damages or Lost profits where non-ASC bracing components have been,or are used. Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com SS-04.21 page 6 SS-SUB-AF035-v0320220408 / • © Seismic Braces V `11111�:p Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Material Specifications Size Range Service Pipe Size:T'-12,DN25-DN100 - Material Carbon Steel Clamp and Hardware.Ductile Iron Brace Member Attachment Fitting. r Finish s ❑ Plain ❑ Clamp:Hot Dipped Galvanized per ASTM A153 cL us Fnn ❑ Brace Member Attachment Fitting: LISTED APPROVED Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and lateral brace clamp designed to connect a piping system to a brace O O member.The AF730 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).FM Tested(ANSI/FM 1950-16). FIG.AF730 Dimensions and Weight Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Size A B Y Weight Features In./mm In./mm In./mm Ibs/kgs Torque offset screw and nuts provide a visual 1"(DN25) 7.6 193 2.49 1.13 indication that the desired installation torque 11/2"(DN32) 8.0 203 2.55 1.13 values have been achieved. 11/2" DN40 8.2 208 2.64 1.20 Ordering ( ) Specify figure number,service pipe size,finish, 2"(DN50) 8.7 221 2.78 1.26 and description. 21/2" 9.2 234 2.92 1.32 DiscLaimer: ASC Engineered Solutions does not provide any warranties 3"(DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4"(1)N100) 10.8 274 3.38 1.53 are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been,or are used. 8" 15.2 386 6.40 2.90 Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered Solutions*"brand bracing components are designed to be compatible ONLY with other AFCON, ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service V.,O `11111�:p Size Pipe Pipe 30°-44° 45`-59` 60°-90° Listed 30`-44` 45°-59° 60°-90° Listed VAN VAN VAN IVAN IVAN VAN VAN VAN Sch.A Mega-Thread 1 Sch.40 MLT/GL 340 480 588 680 340 480 588 680 (DN25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 EZ-Thread Mega-Flow O Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) Metric Pipe EEddd Flow Longitudinal Application ThreaEZ-Thread Mega-Flow MLT/GL 11/2 Sch.10 Mega-Thread Sch.40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo 0 EZ-Thread Mega-Flow 21/2 Sch.10 Eddy Flow Sch.40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 Sch.10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 3 Sch.40 Eddy Flow (DN80) Metric Pipe Fire-Flo 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 51, Sch.10 _ Sch.40 Sch.10 942 1333 1632 1885 942 1333 1632 1885 6 Sch.40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch.10 8" 0.188"Wall - Riser Application Sch.40 10" 0.188"Wall _ Sch.40 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes&UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA13-2019 Section A.18.5.2.3. BUILdIng connections that Last' All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service VAO %IIZ:P Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN bf/kN Sch.10 Mega-Thread V Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow 0 Sch.10 MLT/GL 1Y4" Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Lon itudinatA EZ-Thread g ppllcatlon Mega-Flow Sch.10 MLT/GL 1v2" Sch.40 Mega Thread Y 800 650 790 1800 1790 2530 3100 3460 ( ) DN40 Metric Pipe Eddy Flow Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega Thread Y 830 990 1190 1620 1820 2580 3160 3530 ( ) DN50 Metric Pipe Eddy Flow Eddy Thread 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Fire-Flo EZ-Thread 2h' Sch.10 Edda Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Sch.10 Mega-Flow Lateral Application 3" Sch.40 EddyFlow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 4" Sch.10 Mega-Flow 760 1040 1270 1400 1260 1790 2190 2440 (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 51, Sch.10 _ 890 1230 1410 1550 1260 1790 2190 2440 Sch.40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 6„ Sch.10 Mega-Flow 700 940 1140 1310 950 1340 1640 1830 Sch.40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 8„ 0.188"Wall _ 990 1130 1360 1520 1540 2170 2660 2970 Sch.40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 10" 0.188"Wall _ 1020 850 1000 1100 1700 2410 2950 3290 Riser Application Sch.40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 12" 0.188"Wall _ 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. [moo Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of1.5. BUILdIng connections that Last" See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces rlrs:) / Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe.Unbolt the back nut&bolt and rotate the clamp halves over the service pipe.Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut&bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 3 Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. FIG.AF730 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1",1 Y,",1 v2",2" ASTM A53,Al 06,Al 35,or ✓ ✓ NIPS Pipe A795 Sch.40 Metric Pipe KS D 3562 ✓ ✓ DN25,DN32, EN10255H ✓ Metric Pipe DN40,DN50 GB/T3091 ✓ AS G3454 ✓ FIG.AF730 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 ✓ ✓ KS D 3537 KS D 3562 ✓ ✓ Sch.40 G B/T 3091 ✓ GB/T 3092 DN25,DN32,DN40, JIS G3452 DN50,DN 80,DN100 ✓ EN10255M asc-es.com EN 10255H Building connections that last" ss-07.20 page 4 SS-SUB-AF730-v04 20221228 © NEW 6"D.I. BY OTHERS Q STORAGE LOADI G 39'-6" 70'4" 39'-6" CANOPY DOCK �1 INES FOLLOW SLOPE 6" BELOW PURLINS V-10 V-10" I�RANE SUPPORT CF NE S PPORT INIMUM HEIGHT 17'9" MINIMUM HEIGHT 17'9"� SCOPE OF WORK IN PIPIN 6" BELOW CEILIN THIS SUBMITTAL - EXISTING BUILDING - OTTOM OF CRANE RAIL BEAM Z.T. OF CRANE RAIL BEAM NO WORK THIS SUBMITTAL 0943 ® H, o � 123 NEW 6"D.I.BY OTHERS 2 BUILDING SECTION Scale:1/8"=1' 67TH AVE NE W1 UNDERGROUND NOTES: Source information BURNS FIRE PROTECTION SYSTEMS, INC. TO START AT FLANGE INSIDE OF THE BUILDING. Date of Flow Testl Info:83112023 Locatbn of flow test data BURNS FIRE PROTECTION SYSTEMS, INC. EXPECTS ALL UNDERGROUND 67th ave NE PIPING TO BE FLUSHED PER NFPA STANDARD #13 AND NFPA STANDARD 24 Sounafflow Nst' . AND THAT THE UNDERGROUND SYSTEM WILL BE INSTALLED MEETING THE modeled flow by Ryan Momson-Adington Water PROCEDURES AND STANDARDS SET BY THE WASHINGTON STATE FIRE Source DataP' Pressure I Fbw Pressure Flow MARSHAL AND LOCAL UTILITY REQUIREMENTS 79.00 0.00 WHEN NFPA CERTIFICATE IS SUBMITTED DOCUMENTING 66.00 5000.00 SITE PLAN THE PROPER INSTALLATION AND FLUSH OF THE UNDERGROUND, BURNS 1 FIRE PROTECTION SYSTEMS INC., WILL CONNECT THE INTERIOR AUTOMATIC FIRE SPRINKLER scale:1"=40' SYSTEM TO THE UNDERGROUND FIRE SERVICE AT THE INTERIOR SUPPLY FLANGE. Calculation results for Design Area 1 -SW CORNER This system as shown on Burns Fire Protection.Inc company print no dated 5113116 Calculation results for Design Area 3 -lower mew-nine for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. This system as shown on Burns Fire Protection,Inc company print no dated 5/13/16 contract no is designed to discharge at a rate of 0.15 gpni(L/min/ri of floor area over for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. a maximum area of 1950 fl2 when supplied with water at a rate of 751.3 gom at 66.9 psi at the base of the riser. contract no is designed to discharge at a rate of 0.1 gpni(L/min/m2)of floor area over Hose stream allowance of Is Included in the above. a maximum area of 1950 IF when supplied with water at a rate of 459.3 opm at 70.6 psi at the base of the riser. Occupancy classification:OH1 Number of heads flowing:19 Hose stream allowance of is included in the above. STRUCTURAL STEEL BEAM Commodity classification: System Type: Dry Occupancy classification:Ih Number of heads flowing:19 Dr Maximum storage height: Maximum velocity: 17.43 ills s Commodity classification: System Type: Storage arrangement: Maximum storage height: Maximum velocity: 30.25 ft/s Z-PURLIN Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 66.9 psi Storage arrangementV-13 : Flow from Overhead sprinklers: 501.3 gpm Pressure Available at Source: 78.6 psi Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 70.6 psi Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 11.7 psi Flow from Overhead sprinklers: 359.3 gpm Pressure Available at Source: 78.8 psi G TYPE BEAM CLAMP Flow from Outside Hoses: 250 gpm Flow from Inside Hoses: 0 gpm Su plus Pressure at Sou ce: 8.3 psi SELF TAPPING + Other fixed flows: oaom Flow from Outside Hoses: 100 gpm W/RETAINING STRAP 'F Total flow in system piping: 751.3 gpm "SAMMY"SCREW SWDR, 3/8" -4" & SMALLER PIPE O� Addit tonal flow at/beyond source: 0a0 m Total fixed sy 3gpm Total of all flows: 751.3 gpm Total flow fl system piping: 459.3 gpm Additional flow alPoeyond source: 0 oom Total of all flows: 459.3 gpm 3/8" A.T.R.-4" & SMALLER PIPE Calculation results for Design Area 2 -STORAGE CANOPY This system as shown on Bums Fire Protection,Inc company prim no dated 5/13116 for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. �l contract no is designed to discharge at a rate of 0.1 gpm/W(L/min/m2)of floor area over 3/8 A.T.R. a maximum area of 1950 W when supplied with water at a rate of 669.6 apm at 70.5 psi at the base of the riser. Hose Stream allowance of is included in the above. Occupancy classification:OH2 Number of heads flowing:16 RING HANGER a Commodity classification: System Type: Dry n Maximum storage height: Maximum velocity: 23.43 fVs O NN Storage arrangement: 6 3x2Yh Flow from In-Rack sprinklers: 0 gpm pressure Required at Source: 70.5 psi RING HANGER RED a Flow from Overhead sprinklers: 419.6 gpm Pressure Available at Source: 78.7 psi i0 COUPLI G � n� Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 8.2 psi Flow from Outside Hoses: 250 gpm HANGER 12 HANGERS AT ROOF PURLINS ` <o Other fixed flows: Oopm # #0 4 MAIN HANGER A T BEAMS 'F J'F Total flow in system piping: 669.6 gpm N.T.S. as a "F Additional flow,at/beyond source: 0 opm Total of all flows: 669.6 gpm " RISER OOM 3/8x2" BOLT NUT AND WASHER WORK PERFORMED BY BURNS FIRE PROTECTION SYSTEM,INC.CONSISTS OF: welght/ft mOxim um load at NOT LESS THAN 2" NOMINAL WIDTH. water filed hanger maximum. SIZE PIPE TYPE SCHED. NOM ID pipe � Ocing spacin yy EXTENDING NEW DRY SYSTEM PIPING TO ALL AREAS OF BUILDING AS REQUIRED BY NFPA#13 INCHES / INCHES (pounds) eetJJ ounds ( 1 1/2" ) rd>) SYSTEMS HYDRAULICALLY DESIGNED FOR ORDINARY HAZARD GROUP 1.15 GPMI 1950 4 SQ.FT.00CUPANCIES,IN GALVANIZING AND DIPPING PLAN 1" SCH 40 1.049 2.05 12'0" 24.6 SYSTEM DESIGNED GROUP II.20 GPM/1950 SQ.FT.UNDER STORAGE AND LOADING DOCK CANOPIES 1"1/4" SCH 40 1.380 2.93 12'0" 35.16 LIGHT HAZA FM / SPACING OFRSPIRINKLERS BASED ON 130 SQ.FT.MAXIMUM,EXCEPT IN OFFICE AREAS 225 SQ.FT. 1 1/4'- EDDYFLOW 1.536 5.1 15 0" 56.85 O ASC FIG 55r=0��\ / NOT LESS THAN 3" SIDE BEAM BRACKET\ MAXIMUM 3 1/2 EDDYFLOW 2.314 7.1 15'0" 76.5 NOMINAL THICKNESS TAPPED FOR 3/8" BOLT 4 EDDYFLOW 3.314 10 8 15'O" 162.9 EDDYFLOW 4.31 10.86 150" 601-2 GENERAL NOTES: 6 SCHED 10 6.36 23.03 15'0" 345.45 c2 1/2) $ SCHED 10 B25 40.08 15'0" 6012 RISER DETAIL 1/F P 1 1. DESIGN AND INSTALLATION TO CONFORM WITH NFPA 13, 2019. 2. ALL MATERIALS TO BE NEW AND UL OR FM LISTED. 3/6'D"A. PIPING SYMBOLS: A B 0 1' 2' 3' 4' 3. PROTECTION OF SPRINKLER FROM PAINT BY OTHERS. t'0"ATR 1/z^=1'a^ ��� 4. ALL PIPE THREADED PIPE TO BE BLACK SCH 40 PIPE. 2" MIN. A.T.R.WELDED TO 5. ALL NEW GROOVED PIPE WITH WELDED OUTLETS AND JOINED NTH GROOVED EA.END COUPLINGS TO BE EDDYFLOW. PENETRATION SYSTEM RISER/SUPPLY Components f Approximate Hanger Location 6. FITTINGS TO BE BLACK MALLEABLE IRON OR PAINTED GROOVED. GST 20 FOR 1-2 1/2" PIPE Nt"TRAPEZE ASC/ANVIL FIG 69H RING TYP. 1 6"SUPPLY 7. ALL PIPE ELEVATIONS ARE TAKEN FROM CENTER LINE OF PIPE AND ARE AS f Approximate Bracing Location 3/8°A.T.R.FOR UP To 4"MAIN 2 6'GROOVED BY FLANGE ADAPTER MARKED ON THE DRAWINGS. -�- Approximate Location of Grooved Coupling GST 25 FOR 4' PIPE 3 6x4"REDUCER 8. SYSTEM IS DESIGNED TO DELIVER PER THE NOTES ON THE PLAN. FOR VERTICAL USE. 1/2"A.T.R.FOR 6"MAIN 9. ALL SWAY BRACING TO BE 1" SCH40 PIPE FASTENED PER APPROPRIATE DETAIL. INSTALL IN CENTER 4 4"AMES DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY 10. ALL GROOVED COUPLINGS ARE TO BE RIGID UNLESS NOTED OTHERWISE. +0-0 Elevation from Floor to Centerline of Pipe OF LOWER FACE. 5 4"TYCO DPV-1 DRY VALVE WITH ACCELERATOR 11. GROOVED COUPLINGS TO BE FLEXIBLE COUPLINGS ON MAINS WITH DROPS -0 BOJ Elevation down from Joist to Centerline of Pipe 6 RISER MOUNT AIR COMPRESSOR WITH AIR MAINT.DEVICE-1200 GALLON SYSTE EXCEEDING 7' IN LENGTH. GST PIPE HANGER FOR WOOD MAIN OR 7 (2)21/2"HOSE VALVES FOR FORWARD FLOW TEST OF BACKFLOW PREVENTOR 12. FLOW AND TAMPER SWITCHES TO BE PROVIDED AND INSTALLED BY BURNS FIRE -0 BOB Elevation down from Beam to Centerline of Pipe t'11d �Y/ BRANCH LINES 8 4"CV-1 CHECK VALVE(9.63"T.O.) PROTECTION SYSTEMS, INC. e/, PIPE SPAN A B ASPAIJED EMBER TRAPEZE MODULAS MODULAS 9 ILL MOUNT 13. ALL ELECTRICAL WIRING TO BE PERFORMED BY OTHERS. (0'-0") Center to Center Dimension of Pipe as T1 2Ys SPA4'0 t'a" 2'8" PAN 1Ys"SCHED 40 .33 .27 10 1.ELECT" ELECTRIC BELL 14. FLOW SNATCHES AND TAMPER SNATCHES AS REQUIRED BY CODE. FOR PIPE IN supported by dimensional lumber 15. THE OWNER IS TO PROVIDE MONITORING AS REQUIRED.. O'-0" Cut Dimension of Pipe T2 216 5'0" 3'2" ,',0" 4'6" 11 12 HEAD SPARE HEAD BOX 16. THE NEW ELECTRIC BELL SHALL BE MOUNTED AT 10'-0" ABOVE AND WITHIN 4' 2"SCHED to .34 1 Hydraulic Reference Point CERT. *F INDICATES FLEXIBLE COUPLING HORIZONTALLY OF THE FIRE DEPARTMENT CONNECTION. #86528 ADJUSTED SPAN FOR PIPE LOCATED WHERE TRAPEZE IS NOT CENTERED BETWEEN SUPPORTS BASE ON FOLLOWING FORMULA BURNS FIRE PROTECTION SYSTEMS,INC.TO PROVIDE ALL FLOW AND 17. HEADS ARE TO BE SPACED PER NFPA13 David Yates C.E.T. 4(A)(8) TAMPER SNITCHES-ELECTRIC WIRING AND SYSTEM MONITORING TO BE 18. ALL PENETRATIONS THRU RATED WALLS SHALL BE FIRECAULKED. o • Rise/Drop N.I.C.E.T. Level IV PROVIDED BY OTHERS 19. THIS BUILDING IS MIXED HAZARD OCCUPANCY. Fay PR0'="o" 20. TOTAL NUMBER OF NEW SPRINKLERS= 433 ® Main Sprinkler Riser ExcwEERwc TEceprowcv A+B PATER-BASED SYSI'EYS WYOUT #62 TRAPEZE HANGER DETAIL 21. TOTAL AREA OF BUILDING IS APPROX. 41,965 SQ.FT. NAT ONA N TUTS E N.T.S. 3 (NAS) No Automatic Sprinklers CERT FCAT ONr ENGINE- RISER TECFe101AGR:e. Scale:1/2"=P (NTS) NOT TO SCALE NOTES REVISIONS SPRINKLER SYMBOLS NOTES AND DATE DESCRIPTION BY DETAILS ......... .""""WASHINGTONSTATE......... SYM CNT POSITION FINISH TEMP K NPT SIN MFO. MODEL BURNS FIRE PROTECTION SYSTEMS SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY X 364 uPR WHITE 20o S.6o 1/2' TY3131 T1co TY-FRB FIRE PROTECTION SPRINKLER SYSTEMS: 0 3e JUPR ICHROME 1200 1 5.60 1/2' 1 TY3151 IT1co I TY-B PERMIT NO. VJ 7i 4 30 SIDE WHITE 200 5.60 1/2' TY3351 T1ao TY-B P.O.B. 1110 CONTRACT NO. :David � 18520 67TH AVE NE 2608"0898"C Level /1 ISIDE WHITE 1200 1 5.60 1/2' ITY3331 IT1a, I TY-FRB Burns Fire Protection Systems,Inc. GRANITE FALLS, WA ARLINGTON APPROVAL CITY OF ARLINGTON , WA 98223 DRAWN BY D.YATES M :B SFPB nu g,6/23 425-388-0124 SCALE NOTED E>area: , :Signature Date 12/312 r DATE 9/6/2023 ................................ DESIGN UESTIONS 360-591-5396 Q CONTRACTOR: Rs"sm FP 1 PcoTlsp OP IDGE 2-0 e Design Areal Dry System DA Area 1981.a1 17'7" .5" P RLIN BDP 16' .5� STORAGE CANOPY IN S UP LOPE AT Demand Calculations using Hazen-Williams Method 203 Omupancy Classirsetion: OH2 Design ATea Density: 0.1 a 207 06 205 11 0916 g'T a 20 P - AddNonalOutsideHoss: 0 _ „ 1 •6" —M IN AT 1'4 BOP DesiNotes ATea S¢e. 1950 - 9-6z eh e-e'z NI LINES FOLLOW 2 SLOPE 6"BELOW PURLINS T1 " LOADING ,', N r1 NES B CANOPY 1 1 1 1 STORAGE 000 2 214 212 211 09 91 aka CANOPY &V EXISTING BEAM �T 15-8 'g m 2 , T2 r IS-9 1 I B 1 . -° N-0 I 0 4 0024 5-0z 61 II-z " Im 0-0Pz - 1 91 D ��,`• NONCOMB STIBLE AWNING NO STORAGECO ECTIN A NIN 20 — 1 18-1 a 0141 0140 0138 0- 10-0 I 9-6 I - /-3 /-3 I 3-6 7-fi I 3-6 fi-6 fi 0- 10-0 }Il�z 19-0 1 4" 00421D" IB-014.. r VP�VE 19-J 2-Ms 4 4 J a J Nz 6-]k _ 0 „v0-0 _ „_ 10-0 _ 6- I-0 f e 1 0 _ 9- e 4 ]-Imz _ 9- _ la. 10-0 94 101 c 4 0 OP 0,1A ORp\N „" „.. ��- 1 1 1 1��_ 1 1 � � �_ 1 _ 1 1 }s: „ 19-z 1 4 •25 1 2 1 — - - Q Q - - Q Q - - Q Q - - Q Q - - Q ¢ - - ¢ Q - - Q Q - - Q Q - - - - Q Q - - Q - O - a W W W W W W W W W W W W W W W W W W P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 P2 m m P2 m z o z o z o z o z o z o z o z o z o D a o a o a o a o a o a o a o a o J( a o ;g rr of m rr rc m of m of PI N C) N C) N N N N N N N P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 02 a P2 P2 P2 P2 P2 P2 P2 m P2 P2 F�2 f05 -S 110 `� 5 11 D. S D. -.S D. -S D. -S D. -S D. -S D. -S .b .b .b ORp\N NP\'VE BOI 01\A P 2 P2 P2 P2 P2 P2 P2 P2 P2 P2 lo-a }mv g to-6 _ _ _ CHANNELS 6"� ' }a: 104 11 ,16 -FLOOR STEPS 5" O -d _1 -d ns J r .m 5,z- 3 Y d io-i 03^ 1 f 1 113 117 3/S3 0 2 2 2 2 _ - - 2 _ '2 m r 5' 0" 5' 0" d RAIN VALVE P3 O m OWN TO LOWER p MEZZANINE PIPING m ,oz 7 � 1 116 B.2, P3 LL h�l M Desi n Area 1 D S stem w w w w w w w w is-u a 4 SW CORNER _ _ _ _ _ _ _ _ _ _ Demand CalculiLions using HazemWilliams Method 3 Ccclpancy Clasthcadon: OH, 101 106 0 Design Area Desity: 0.15 (E) OFFICE Additional Outsi]a Hose AREA TO io Design Area Si : 1950 ,t, P3 REMAIN Notes: K = A ANa q - - - 10'- - - - 5-0- -o,• 0•_0•• - - - - '�� a - - - - - - - - - - - - ' �ro c� 110'o LEVEL - 2n ..—.i SPECTORS TEST P3 PURLIN SCHEDULE p3 MARK SIZE NOTES P1 8Z16 (E) ROOF PURLIN, DO - - - 3 - - - - - - - - - - - NOT HANG SPRINKLERS -` FROM P1 PURLINS P3 P2 8Z16 (E) CRANE W-RAFTER PURLIN, HANG 8.1 SPRINKLER BRANCH LINES PER PLAN BOTTO F CRA RAIL 6'7" AND KEY NOTE 1 P3 P3 8Z16 (E) W-RAFTER PURLIN, HANG m\ _ SPRINKLER BRANCH LINES PER PLAN P3 o AND KEY NOTE 2 D g KEY NOTES: cn 9�53 TTOM GRAN RAIL 1 D TOP 19.1 T =S `ARP\N VP�'vE 1 2"0 PIPE MAX SPRINKLER BRANCH LINE LOCATION GRID O - _ - _ - _ _ - - _ _ W c A-B &B-C. HANG SPRINKLER LINE FROM EACH P-2 0 PURLIN (SPACING VARIES) 2 2"0 PIPE MAX SPRINKLER BRANCH LINE LOCATION GRID q B-C. HANG SPRINKLER FROM EACH P-3 PURLIN \ \ \ \ e+ VE 1 oRp\N�P 5'-0" O.C.) V4\j 3 6"0 PIPE MAX SPRINKLER MAIN LINE LOCATION. HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 f P2 c -MAIN ALONG SIDE SPRINKLER LINE FROM (E) CRANE W-RAFTER ONLY. DO OF BEAM NOT HANG FROM (E) 2C RAFTER OR (E) PURLINS. SEE SUPPORT FROM PLAN NOTE 5 O TOP FLANGE OF BEAM = 4 6"OPIPE MAX SPRINKLER MAIN LINE LOCATION. HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 D SPRINKLER LINE FROM (E) W-RAFTER ONLY. DO HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 � �2 P1 FROM FROM (E) PURLINS. SEE PLAN NOTE 5 -0, a -a �a, a -a ��, a -a ��, a -a �a, -a ��, a -�, -�, a -�, -�, a -h 02 -�,� a a w a w a w a w a w a w a w a a w a w a w a w m m m m m m m m m m m m m m m m m m m m m T m 5 BLOCKING PER 4/53.0 AT P2 MID-SPAN Z O Z O Z O z O Z O Z O z O Z z O z O z P2 a m P2 x P2 a P2 P2 P2 P2 a P2 a P2 P2 a P2 P2 `a m m m � -d cb U -d cb U -d cb U -d cb U -d cb U -d ab U -d cb U -d -b cbc7 N N n n N N V NO n ♦ .m 0936 ..}s: OP�Sa bR Ix a i ,I, f4a 4 -.S ? V", �g"f ?4 4 J 4 4 ,o-o ,o-o lo-g e-s= _ -- --- - b 0094 aos6 FPl 2 2-6 -6 }6 -6 6 -6 81-6� 6- 3- 10-0 ]- 2- I 8- 9- 0-0 9-6 0-0 10-0 2 ,U-0 0939 A --__ - -- ---_- 0940 1&-019^s • 7- WALL MOUNT F.D.C. i0o--oi i p 20'-0" 20'-0" 20'-0" 20'- " 20'-0" 20'-0" 20'-0" 20'-0" 2 '-0" 21'-0" 20'-0" 20'-0" �°-0�° oa�EroauN a"e _ CERT.#86528 25" WALL GERTS suwoa,raoN,o>ovaFun David Yates C.E.T. O O O O O O O O O 2 O N LC E T Level IV 1 2 3 4 6 7 8 9 10 11 2 @tG1NEEnWG TECfLN01AGY D IN VALVE " PURLIN IN MIDDLE xATaR-6Asm srsraus umuT NATIONAL P,STNVTE FOR fPl 3 �Taeoio g NcweeRec 240'-0" SEISMIC ZONE OF INFLUENCE #1 s. N NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN ••--••• DATE DESCRIPTION BY .�, N N Ni M K N IN MG. MODEL BURNS FIRE PROTECTION SYSTEMS ROOF LEVEL WASNINGTON STATE••••--•' 364 UPR WHITE 200 5.60 ,/2" TY3,3, ryro ,~-FRD SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY Q 38 uPR CHROME zaa 5.60 ,/2" TY3151 Tyco TY-B PERMIT N0. FIRE PROTECTION SPRINKLER SYSTEMS; Nr E. d 30 510E WHITE 200 5.60 t/2" TY3351 Tyco TY-B P.O.B. 1110 CONTRACT NO. David Yates ., 910E WHITE z00 5.60 ,/2" TY3331 Tyco Tr-FRB 18520 67TH AVE NE 2605.0898•C Level Burns Fire Protection systems,Inc. GRANITE FALLS, WA APPROVAL ARLINGTON, WA 98223 DRAWN BY D.YATES S B SFP8 Du 9/6/23 425-388-0124 SCALE 1/8" = V-0" ' Expires: , Signature Date 12f31/2 DATE 9/6/2023 ---•--"••••••••••••••••••• DESIGN QUESTIONS 360-591-5396 CONTRACTOR: REN6 3 FP 2 PLOT,ED 9'-5" DA Name:3 DA Area:2022.68 1 1 4 1 1 4 0- 10-0 10-6 2-6 1- 1 304 309 WOMENS 322 -2 z BELOW FOLLOWCEILI G SLOPE 1 1 OTS WITH 1'DEEP BEAM 6" M _ 1_ N 12" DEEP BEAM 1'4 fl *5 1 2 Boo O 1-5 N Cn 6-4 AFF °° DROP IN WH CLOSET 114 1' O 01 1a-10 REF 4" N MENS 61 6 AFF 321 TO LINE BELOW STAIR o- 10-0 10-s 2-s 1 2 STOR 0010 CORRI O 6-6 REF SIN o, 2 1 314 318 002 4„ 2 8-2'2 &2' 0012 M41 SLOPED CEILING NN6-512Ce. 12 r- _ CEILNG STARTS AT 68 2 Ln *6 BODAFF a2 J 2 h 2 2 q2 - " � L � 7_2 REFTO O 2- ° °) 7-11 z -8 N °�9l z 3-11' w 112 0 14'-7 1/4" 0-6 0 0021 x &� o, -9 3-2 0-1 2 3-7 1 1 306 0013 0�. . - 2 0046 048 N - z 7 3 7 BDD i -6 1 1 16 REF (D OFFICE " ^10 z 2-4 N 311 ` � DRUM DRIP DRAIN CN s "' Ln *s BOD IN WATER HEATER 7-2 AFF CLOSET " 7-2 REF —_ 305 coRRl 16 LOBBY LINE BELOW STAIRS 112 1'2 112 N M 1-112 3-3 g_glz 5-1 OPEN TO ABOVE N 1 " 0-10 r ° " 6-5 3 2 0017 CN Design Area 3 Dry System CEILINGS CORRIDOR 1 lower mewzzanine 307 308 0018 316 2-6 s-1 2 o Demand Calculations using Hazen-Williams Method Occupancy Classification: Ih o 1,z 1'2 1,z 1'2 3-1'z 4-3 z 2-5 Design Area Density: 0.1 3-11z 301 9-2' 7-912 0-6 Additional Outside Hose: 0 OFFICE OFFICE OFFICE Design Area Size: 1950 OFFICE Notes: calulations include all of lower mezzanine ceiling 71011 (� 2ND MEZ UNLESS NOTED OTHERWISE CEILING ELEVATION: MAIN PIPE ELEVATION: BRANCH PIPE ELEVATION: ELEVATION FROM JOB REF: 8'6" 1 LOWER MEZZANINE PIPING UPPER MEZZANINE PIPING CERT.#86528 Scale: 1/4"=1' 2 David Yates C.E.T. Scale: 1/4"-1' N t Fo,R T. Le-1 N — @tG1NEERWG TECfR,OLOGY AATRR-BA6®SY6TRY6 LAYOUT NATIONAL R,SITTUTE FOR CRRTR+ICAT[ON RI II,GRiRRRING TEC@IOIAGIRB. N NOTES REVISIONS SPRINKLER SYMBOLS MEZZANINE -•----• DATE DESCRIPTION BY W NI H M K N IN M D. MODEL BURNS FIRE PROTECTION SYSTEMS ROOF LEVEL WASNINGTON STATE......... WHITE 200 e.6o ,/2" TY3,3, Tyco ,~-FRD SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY CHROME 20a 5.60 ,/2" TY3151 Tyco TY-B PERMIT NO. FIRE PROTECTION SPRINKLER SYSTEMS;NrE. WHITE 2aa 5.60 t/2" TY3351 Tyco TY-B P.0.B. 1110 CONTRACT NO. pevidYete. WHITE 200 5.60 ,/2" TY3331 Tyco Tr-FRB 18520 67TH AVE NE 2605.0898•C Level F Burns Fire Protection systems,Inc. GRANITE FALLS, WA APPROVAL S B SFPB ou 9623 ARLINGTON, WA 98223 DRAWN BY D.YATES Eyre.: , 425-388-0124 SCALE 1/4" = V-0- Sgneture-----"•,--Date--_-12fbV2- : DATE 9/6/2023 DESIGN QUESTIONS 360-591-5396 CONTRACTOR: REN6m FP 3 PLo ED CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 1 Demand (HW) OH1 1950 751.3 Required 0.179 7 21.2 19 250 11.7 66.9 WASHINCaTON STATE ---- ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , , David Yates 2606-0898-C Level Burns Fire Protection Systems,Inc. B VS 1bU 9/6/23 Expires: 14 Signature Date 12/31/23 ................. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 1 Remote Area Location SW CORNER Occupancy Classification OH1 Density(gpm/ft2) 0.179 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 118.3 Number of Calculated Sprinklers 19 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 751.3 Required Pressure at Source(psi) 66.9 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 1 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.6 751.3 66.9 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 250 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 501.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 501.3 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 66.9 W1 -Flow(gpm) 751.3 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 a supply♦Supply;Safety Pressure f System Demand • Available At Source 10 90 78.6 psi @ 751.3 glom 00 8 � 70 ~ D2 -- C:,2 63 493 60 !Z N 7 50 fq d a 4 3 20 D1 1 10 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 13.6 D2 I System Demand 751.3 66.9 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.5 836.1 11.7 751.3 Supply;Safety Pressure 70.7 780.2 3.9 751.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 102 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 8 Sprinkler 103 Overhead 118.3 8 0.15 17.7 7 0.209 24.7 9.5 Sprinkler 104 Overhead 118.3 8 0.15 17.7 7 0.233 27.6 11.9 Sprinkler 105 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 106 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 107 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 7.9 Sprinkler 108 Overhead 118.3 8 0.15 17.7 7 0.208 24.6 9.5 Sprinkler 109 Overhead 118.3 8 0.15 17.7 7 0.233 27.5 11.8 Sprinkler 110 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 111 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 112 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 7.9 Sprinkler 113 Overhead 118.3 8 0.15 17.7 7 0.208 24.6 9.5 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 114 Overhead 118.3 8 0.15 17.7 7 0.233 27.5 11.8 Sprinkler 115 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 116 Overhead 118.3 8 0.15 17.7 7 0.23 27.2 11.5 Sprinkler 117 Overhead 118.3 8 0.15 17.7 7 0.24 28.4 12.6 Sprinkler 118 Overhead 118.3 8 0.15 17.7 7 0.257 30.4 14.4 Sprinkler 119 Overhead 118.3 8 0.15 17.7 7 0.282 33.4 17.4 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 111 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.4 0.179 -13.6 17.7 106 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.4 0.179 -13.6 17.7 101 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.5 0.179 -13.6 17.7 112 Overhead Sprinkler 8 22.6 118.3 7.9 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 107 Overhead Sprinkler 8 22.6 118.3 7.9 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 102 Overhead Sprinkler 8 22.6 118.3 8 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 113 Overhead Sprinkler 8 24.6 118.3 9.5 7 24.95 HEAD Open 6.9 0.208 -12.1 17.7 108 Overhead Sprinkler 8 24.6 118.3 9.5 7 24.95 HEAD Open 6.9 0.208 -12.1 17.7 103 Overhead Sprinkler 8 24.7 118.3 9.5 7 24.95 HEAD Open 6.9 0.209 -12.1 17.7 116 Overhead Sprinkler 8 27.2 118.3 11.5 7 26.65 HEAD Open 9.4 0.23 -12.8 17.7 114 Overhead Sprinkler 8 27.5 118.3 11.8 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 109 Overhead Sprinkler 8 27.5 118.3 11.8 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 104 Overhead Sprinkler 8 27.6 118.3 11.9 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 117 Overhead Sprinkler 8 28.4 118.3 12.6 7 24.95 HEAD Open 10.7 0.24 -12.1 17.7 118 Overhead Sprinkler 8 30.4 118.3 14.4 7 23.4 HEAD Open 12.6 0.257 -11.4 17.7 115 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.6 0.265 -10.8 17.7 110 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.6 0.265 -10.8 17.7 105 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.7 0.265 -10.8 17.7 119 Overhead Sprinkler 8 33.4 118.3 17.4 7 21.97 HEAD Open 15.6 0.282 -10.8 17.7 0141 Node 34.8 17.99 NODE -9.1 0140 Node 34.8 17.96 NODE -9.1 0030 Node 34.8 18.01 NODE -9.1 0138 Node 34.9 17.94 NODE -9.1 0096 Node 43.2 18.02 NODE -9.1 0938-0 Node 50.7 5.28 NODE -3.6 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0938-I Node 52 4.14 NODE -3.1 0939-0 Node 53 2.09 INODE -2.2 0939-I Node 62.1 1.93 NODE -2.1 0940 Node 62.8 0.5 NODE -1.5 H1 Outside Hose 250 64.5 -3 IHOSE 0 250 0943 Node 64.6 -3 NODE 0 0944-0 Node 65.9 -3 NODE 0 0944-I Node 66 -3 NODE 0 0945 Node 66.5 -3 NODE 0 wi Supply -751.3 66.9 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 ill 28.35 8 21.2 1.5 11.85 100 7 112 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 112 26.65 8 22.6 1.5 11.85 100 7.9 113 24.95 8 43.7 1.728 0 0.068 0.7 11.85 0.8 113 24.95 8 24.6 1.5 10.81 100 9.5 114 23.4 8 68.4 1.728 0 0.1557 0.7 10.81 1.7 114 23.4 8 27.5 1.5 9.98 100 11.8 115 21.97 8 95.9 1.728 0 0.2914 0.6 9.98 2.9 115 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.89 100 15.4 0140 17.96 127.3 1.728 lx(90 ell)=4.02 12.07 0.4922 1.7 35.96 17.7 0140 17.96 13.9 4 10 100 34.8 0138 17.94 141.2 4.31 0 0.007 0.0 10 0.1 0138 17.94 119.3 4 5x(90 ell)=33.29 351.41 100 34.9 0096 18.02 260.5 4.31 33.29 0.0216 0.0 384.7 8.3 0096 18.02 240.8 4 2x(90 ell)=13.32 13.85 100 43.2 0938-0 5.28 501.3 4.31 13.32 0.0727 5.5 27.17 2 0938-0 5.28 0 4 1.14 50.7 DPV-1 0938-I 4.14 501.3 0 0 0.7591 0.5 *** 1.14 0.9 0938-I 4.14 0 4 2.04 120 52 0939-0 2.09 501.3 4.31 0 0.0519 0.9 2.04 0.1 0939-0 2.09 0 4 0.17 53 Ames 0939-I 1.93 501.3 0 0 54.2493 0.1 Deringer 30 0.17 9 *** 0939-I 1.93 0 4 1.43 120 62.1 0940 0.5 501.3 4.31 0 0.0519 0.6 1.43 0.1 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 62.8 0943 -3 501.3 6.4 34.91 0.0057 1.5 44.03 0.3 0943 -3 250 6 104.43 140 64.6 0944-0 -3 751.3 6.4 0 0.012 0 104.43 1.3 0944-0 -3 0 6 0.88 65.9 Gate A2360 0944-I -3 751.3 0 0 0.1131 0 *** 0.88 0.1 0944-I -3 0 6 lx(tee-Br)=43.72 1.21 140 66 0945 -3 751.3 6.4 43.72 0.012 0 44.931 0.5 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0945 -3 0 8 124.91 140 66.5 W 1 -3 751.3 8.55 0 0.0029 0 124.91 0.4 W 1 66.9 Path No: 2 106 28.35 8 21.2 1.5 11.85 100 7 107 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 107 26.65 8 22.6 1.5 11.85 100 7.9 108 24.95 8 43.7 1.728 0 0.0681 0.7 11.85 0.8 108 24.95 8 24.6 1.5 10.81 100 9.5 109 23.4 8 68.4 1.728 0 0.1558 0.7 10.81 1.7 109 23.4 8 27.5 1.5 9.98 100 11.8 110 21.97 8 95.9 1.728 0 0.2916 0.6 9.98 2.9 110 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.86 100 15.4 0141 17.99 127.3 1.728 1x(90 ell)=4.02 12.07 0.4924 1.7 35.93 17.7 0141 17.99 -13.9 4 10 100 34.8 0030 18.01 113.4 4.31 0 0.0046 0.0 10 0.0 0030 18.01 127.4 4 lx(tee-Br)=16.69 389.77 100 34.8 0096 18.02 240.8 4.31 6x(90 ell)=39.95 56.64 0.0187 0 446.421 8.4 0096 43.2 Path No: 3 101 28.35 8 21.2 1.5 11.85 100 7 102 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 102 26.65 8 22.6 1.5 11.85 100 8 103 24.95 8 43.8 1.728 0 0.0682 0.7 11.85 0.8 103 24.95 8 24.7 1.5 10.81 100 9.5 104 23.4 8 68.4 1.728 0 0.1561 0.7 10.81 1.7 104 23.4 8 27.6 1.5 9.98 100 11.9 105 21.97 8 96 1.728 0 0.2921 0.6 9.98 2.9 105 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.83 100 15.4 0030 18.01 127.4 1.728 1x(90 ell)=4.02 12.07 0.4933 1.7 35.9 17.7 0030 34.8 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 116 26.65 8 27.2 1.5 11.85 100 11.5 117 24.95 8 27.2 1.728 0 0.0282 0.7 11.85 0.3 117 24.95 8 28.4 1.5 10.81 100 12.6 118 23.4 8 55.6 1.728 0 0.1061 0.7 10.81 1.1 118 23.4 8 30.4 1.5 9.98 100 14.4 119 21.97 8 85.9 1.728 0 0.238 0.6 9.98 2.4 119 21.97 8 33.4 1.5 lx(tee-Br)=8.05 23.91 100 17.4 0138 17.94 119.3 1.728 1x(90 ell)=4.02 12.07 0.437 1.7 35.99 15.7 0138 34.9 Path No: 5 H1 -3 250 6 lx(tee-Br)=43.72 1.76 140 64.5 0943 -3 250 6.4 43.72 0.0016 0 45.48 0.1 0943 64.6 Path No: 6 0141 17.99 0 4 10 100 34.8 0140 17.96 13.9 4.31 0 0.0001 0.0 10 0 0140 34.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 17.43 ft/s occurs in the following pipe(s): (0030-105) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 1; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 11.1 c. 1o.1s 9 psi @ 501.3 gpm ., m L 7 9.1 40) 8.1 L. d 7.1 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 13 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 1; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1.9 0.9psi' 501.39pm 0.9 0 0 0 0 0 0 0 0 0 0 o c o 0 o o n o n o 0 o v o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 1; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @a 751.3 gpm o c c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 14 CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 2 Demand (HW) OH2 1950 669.6 Required 0.2 18.7 24.2 16 250 8.2 70.5 -- WASHINGTON STATE - ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , , David Yates 2605.0898-C Leve13 Burns Fire Protection Systems,Inc. 8 SFPB '!bU ' / 9/6/23 rJExpires: ; S19nature Date 12/31/23 ................................ File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 2 Remote Area Location STORAGE CANOPY Occupancy Classification OH2 Density(gpm/ft2) 0.2 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 121 Number of Calculated Sprinklers 16 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 669.6 Required Pressure at Source(psi) 70.5 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 2 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.7 669.6 70.5 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 250 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 419.6 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 419.6 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 70.5 W1 -Flow(gpm) 669.6 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 a supply♦Supply;Safety Pressure f System Demand • Available At Source 10 90 78.7 psi @ 669.6 gpm 800 � D2 70 ~ -- C:,2 63 493 6 .y !Z N 7 50 N d a a 3 2 D1 1 1 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 9.3 D2 I System Demand 669.6 70.5 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.6 716.3 8.2 669.6 Supply;Safety Pressure 70.8 671.4 0.3 669.6 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead 121 5.6 0.2 24.2 18.7 0.228 27.6 24.2 Sprinkler 202 Overhead 121 5.6 0.2 24.2 18.7 0.23 27.9 24.8 Sprinkler 203 Overhead 121 5.6 0.2 24.2 18.7 0.236 28.5 25.9 Sprinkler 204 Overhead 121 5.6 0.2 24.2 18.7 0.22 26.7 22.7 Sprinkler 205 Overhead 121 5.6 0.2 24.2 18.7 0.215 26 21.6 Sprinkler 206 Overhead 121 5.6 0.2 24.2 18.7 0.212 25.7 21.1 Sprinkler 207 Overhead 121 5.6 0.2 24.2 18.7 0.2 24.2 18.7 Sprinkler 208 Overhead 121 5.6 0.2 24.2 18.7 0.202 24.5 19.1 Sprinkler 209 Overhead 121 5.6 0.2 24.2 18.7 0.208 25.1 20.1 Sprinkler 210 Overhead 121 5.6 0.2 24.2 18.7 0.251 30.3 29.3 Sprinkler 211 Overhead 121 5.6 0.2 24.2 18.7 0.222 26.8 22.9 Sprinkler 212 Overhead 121 5.6 0.2 24.2 18.7 0.216 26.2 21.8 Sprinkler 213 Overhead 121 5.6 0.2 24.2 18.7 0.214 25.9 21.3 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 214 Overhead 121 5.6 0.2 24.2 18.7 0.201 24.4 18.9 Sprinkler 215 Overhead 121 5.6 0.2 24.2 18.7 0.204 24.7 19.4 Sprinkler 216 Overhead 121 5.6 0.2 24.2 18.7 0.209 25.3 20.4 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 207 Overhead Sprinkler 5.6 24.2 121 18.7 18.7 18.49 HEAD Open 0 0.2 -9.3 24.2 214 Overhead Sprinkler 5.6 24.4 121 18.9 18.7 18.49 HEAD Open 0.2 0.201 -9.3 24.2 208 Overhead Sprinkler 5.6 24.5 121 19.1 18.7 17.86 HEAD Open 0.3 0.202 -9 24.2 215 Overhead Sprinkler 5.6 24.7 121 19.4 18.7 17.86 HEAD Open 0.5 0.204 -9 24.2 209 Overhead Sprinkler 5.6 25.1 121 20.1 18.7 17.23 HEAD Open 0.9 0.208 -8.8 24.2 216 Overhead Sprinkler 5.6 25.3 121 20.4 18.7 17.23 HEAD Open 1.1 0.209 -8.8 24.2 206 Overhead Sprinkler 5.6 25.7 121 21.1 18.7 18.48 HEAD Open 1.5 0.212 -9.3 24.2 213 Overhead Sprinkler 5.6 25.9 121 21.3 18.7 18.48 HEAD Open 1.7 0.214 -9.3 24.2 205 Overhead Sprinkler 5.6 26 121 21.6 18.7 17.82 HEAD Open 1.8 0.215 -9 24.2 212 Overhead Sprinkler 5.6 26.2 121 21.8 18.7 17.82 HEAD Open 2 0.216 -9 24.2 204 Overhead Sprinkler 5.6 26.7 121 22.7 18.7 17.15 HEAD Open 2.5 0.22 -8.7 24.2 211 Overhead Sprinkler 5.6 26.8 121 22.9 18.7 17.15 HEAD Open 2.6 0.222 -8.7 24.2 201 Overhead Sprinkler 5.6 27.6 121 24.2 18.7 18.49 HEAD Open 3.4 0.228 -9.3 24.2 202 Overhead Sprinkler 5.6 27.9 121 24.8 18.7 17.86 HEAD Open 3.7 0.23 -9 24.2 203 Overhead Sprinkler 5.6 28.5 121 25.9 18.7 17.23 HEAD Open 4.3 0.236 -8.8 24.2 210 Overhead Sprinkler 5.6 30.3 121 29.3 18.7 17.23 HEAD Open 6.1 0.251 -8.8 24.2 0946 Node 23.6 15.79 NODE -8.1 0002 Node 23.9 15.76 NODE -8.1 0011 Node 26.4 15.79 NODE -8.1 0009 Node 26.7 15.75 NODE -8.1 0008 Node 28.2 15.73 NODE -8.1 0916 Node 30.1 15.79 NODE -8.1 0915 Node 30.5 15.75 NODE -8.1 0024 Node 32 15.73 NODE -8.1 0027 Node 45.1 17.75 NODE -9 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0042 Node 45.7 19.25 NODE -9.6 0096 Node 50.8 18.02 NODE -9.1 0938-0 Node 57.8 5.28 NODE -3.6 0938-I Node 58.9 4.14 NODE -3.1 0939-0 Node 59.8 2.09 NODE -2.2 0939-I Node 66.3 1.93 NODE -2.1 0940 Node 67 0.5 NODE -1.5 H1 Outside Hose 250 68.6 -3 HOSE 0 250 0943 Node 68.7 -3 INODE 0 0944-0 Node 69.7 -3 NODE 0 0944-I Node 69.8 -3 NODE 0 0945 Node 70.2 -3 NODE 0 wi Supply -669.6 70.5 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 207 18.49 5.6 24.2 1.5 8.52 100 18.7 208 17.86 5.6 24.2 1.728 0 0.0228 0.3 8.52 0.2 208 17.86 5.6 24.5 1.5 8.52 100 19.1 209 17.23 5.6 48.7 1.728 0 0.0831 0.3 8.52 0.7 209 17.23 5.6 25.1 1.5 1x(tee-Br)=8.05 3.62 100 20.1 0946 15.79 73.8 1.728 1x(90 ell)=4.02 12.07 0.1796 0.6 15.7 2.8 0946 15.79 0 2.5 14.17 100 23.6 0002 15.76 73.8 2.705 0 0.0202 0.0 14.17 0.3 0002 15.76 74.3 2.5 1x(90 ell)=4.56 53.94 100 23.9 0008 15.73 148.1 2.705 4.56 0.0735 0.0 58.5 4.3 0008 15.73 157.2 2.5 1x(tee-Br)=11.46 2 100 28.2 0024 15.73 305.3 2.705 11.46 0.2807 0 13.46 3.8 0024 15.73 114.3 2.5 1x(tee-Br)=11.46 11.67 100 32 0027 17.75 419.6 2.705 1x(90 ell)=4.56 16.02 0.5059 -0.9 27.68 14 0027 17.75 -177.2 4 5x(90 ell)=33.29 275.7 100 45.1 0096 18.02 242.4 4.31 33.29 0.0189 -0.1 308.99 5.9 0096 18.02 177.2 4 2x(90 ell)=13.32 13.85 100 50.8 0938-0 5.28 419.6 4.31 13.32 0.0523 5.5 27.17 1.4 0938-0 5.28 0 4 1.14 57.8 DPV-1 0938-I 4.14 419.6 0 0 0.5398 0.5 *** 1.14 0.6 0938-I 4.14 0 4 2.04 120 58.9 0939-0 2.09 419.6 4.31 0 0.0373 0.9 2.04 0.1 0939-0 2.09 0 4 0.17 59.8 Ames 0939-I 1.93 419.6 0 0 38.3815 0.1 Deringer 30 0.17 6.4 *** 0939-I 1.93 0 4 1.43 120 66.3 0940 0.5 419.6 4.31 0 0.0373 0.6 1.43 0.1 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 67 0943 -3 419.6 6.4 34.91 0.0041 1.5 44.03 0.2 0943 -3 250 6 104.43 140 68.7 0944-0 -3 669.6 6.4 0 0.0097 0 104.43 1 0944-0 -3 0 6 0.88 69.7 Gate A2360 0944-I -3 669.6 0 0 0.1136 0 *** 0.881 1 0.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0944-I -3 0 6 lx(tee-Br)=43.72 1.21 140 69.8 0945 -3 669.6 6.4 43.72 0.0097 0 44.93 0.4 0945 -3 0 8 124.91 140 70.2 W 1 -3 669.6 8.55 0 0.0024 0 124.911 1 0.3 W 1 70.5 Path No: 2 214 18.49 5.6 24.4 1.5 8.52 100 18.9 215 17.86 5.6 24.4 1.728 0 0.023 0.3 8.52 0.2 215 17.86 5.6 24.7 1.5 8.52 100 19.4 216 17.23 5.6 49 1.728 0 0.0841 0.3 8.52 0.7 216 17.23 5.6 25.3 1.5 lx(tee-Br)=8.05 3.65 100 20.4 0002 15.76 74.3 1.728 1x(90 ell)=4.02 12.07 0.1816 0.6 15.73 2.9 0002 23.9 Path No: 3 206 18.48 5.6 25.7 1.5 8.53 100 21.1 205 17.82 5.6 25.7 1.728 0 0.0254 0.3 8.53 0.2 205 17.82 5.6 26 1.5 8.53 100 21.6 204 17.15 5.6 51.7 1.728 0 0.0929 0.3 8.53 0.8 204 17.15 5.6 26.7 1.5 lx(tee-Br)=8.05 3.53 100 22.7 0011 15.79 78.4 1.728 1x(90 ell)=4.02 12.07 0.2006 0.6 15.61 3.1 0011 15.79 0 2.5 14.17 100 26.4 0009 15.75 78.4 2.705 0 0.0226 0.0 14.17 0.3 0009 15.75 78.9 2.5 lx(tee-Br)=11.46 6.32 100 26.7 0008 15.73 157.2 2.705 11.46 0.0821 0 17.77 1.5 0008 28.2 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 213 18.48 5.6 25.9 1.5 8.53 100 21.3 212 17.82 5.6 25.9 1.728 0 0.0257 0.3 8.53 0.2 212 17.82 5.6 26.2 1.5 8.53 100 21.8 211 17.15 5.6 52 1.728 0 0.094 0.3 8.531 1 0.8 211 17.15 5.6 26.8 1.5 lx(tee-Br)=8.05 3.58 100 22.9 0009 15.75 78.9 1.728 1x(90 ell)=4.02 12.07 0.2029 0.6 15.65 3.2 0009 26.7 Path No: 5 201 18.49 5.6 27.6 1.5 8.52 100 24.2 202 17.86 5.6 27.6 1.728 0 0.029 0.3 8.52 0.2 202 17.86 5.6 27.9 1.5 8.52 100 24.8 203 17.23 5.6 55.4 1.728 0 0.1057 0.3 8.52 0.9 203 17.23 5.6 28.5 1.5 lx(tee-Br)=8.05 3.62 100 25.9 0916 15.79 84 1.728 1x(90 ell)=4.02 12.07 0.2279 0.6 15.7 3.6 0916 15.79 0 2.5 14.17 100 30.1 0915 15.75 84 2.705 0 0.0257 0.0 14.17 0.4 0915 15.75 30.3 2.5 2x(tee-Br)=22.91 8.32 100 30.5 0024 15.73 114.3 2.705 22.91 0.0455 0 31.23 1.4 0024 32 Path No: 6 210 17.23 5.6 30.3 1.5 lx(tee-Br)=8.05 3.67 100 29.3 0915 15.75 30.3 1.728 1x(90 ell)=4.02 12.07 0.0346 0.6 15.74 0.5 0915 30.5 Path No: 7 H1 -3 250 6 lx(tee-Br)=43.72 1.76 140 68.6 0943 -3 250 6.4 43.72 0.0016 0 45.48 0.1 0943 68.7 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 8 0027 17.75 0 4 2x(90 ell)=13.32 110.43 100 45.1 0042 19.25 177.2 4.31 13.32 0.0106 -0.6 123.75 1.3 0042 19.25 0 4 1x(tee-Br)=16.69 385.05 100 45.7 0096 18.02 177.2 4.31 4x(90 ell)=26.63 43.33 0.0106 0.5 428.381 1 4.5 0096 50.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 23.43 ft/s occurs in the following pipe(s): (0027-0024) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 2; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 z 11.1 Q' 10.15 L 7 9.1 N L8.1 L 6.4 psi @ 419.6 gpm d 7.1 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 14 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 2; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1100, 1.9 - 0.6 psi @ 419.6 gpm 0.9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o o n o n o 0 o v o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 2; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @ 669.6 gpm 0 o c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 15 CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 3 Demand (HW) Ih 1950 459.3 Required 0.161 7 14.8 19 100 8.3 70.6 WASHINGTON STATE ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , David Yates 2606-0898-C Level Burns Fire Protection Systems,Inc. B ZPB 1bU Expires: ; 9/6/23 t 2/31 R3 Sign2ture Date ................................ File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 3 Remote Area Location lower mewzzanine Occupancy Classification Ih Density(gpm/ft2) 0.161 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 91.94 Number of Calculated Sprinklers 19 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 100 Total Water Required(incl. Hose Streams)(gpm) 459.3 Required Pressure at Source(psi) 70.6 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes calulations include all of lower mezzanine File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 3 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.8 459.3 70.6 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 100 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 100 Sprinklers Ovehead Sprinkler Flow(gpm) 359.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 359.3 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 70.6 W1 -Flow(gpm) 459.3 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 a supply♦Supply;Safety Pressure f System Demand • Available At Source 100 90 78.8 psi @ 459.3 gpm 80 D2 70 63 493 6 .y !Z N 7 50 N d a a 3 20 D1 1 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 4.4 D2 I System Demand 459.3 70.6 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.8 489.5 8.3 459.3 Supply;Safety Pressure 71 460.9 0.4 459.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 301 Overhead 91.94 5.6 0.1 9.2 7 0.168 15.4 7.6 Sprinkler 302 Overhead 91.94 5.6 0.1 9.2 7 0.172 15.9 8 Sprinkler 303 Overhead 91.94 5.6 0.1 9.2 7 0.206 18.9 11.4 Sprinkler 304 Overhead 91.94 5.6 0.1 9.2 7 0.197 18.1 10.4 Sprinkler 305 Overhead 91.94 5.6 0.1 9.2 7 0.196 18 10.3 Sprinkler 306 Overhead 91.94 5.6 0.1 9.2 7 0.207 19 11.6 Sprinkler 307 Overhead 91.94 5.6 0.1 9.2 7 0.166 15.3 7.4 Sprinkler 308 Overhead 91.94 5.6 0.1 9.2 7 0.166 15.3 7.4 Sprinkler 309 Overhead 91.94 5.6 0.1 9.2 7 0.229 21 14.1 Sprinkler 310 Overhead 91.94 5.6 0.1 9.2 7 0.168 15.4 7.6 Sprinkler 311 Overhead 91.94 5.6 0.1 9.2 7 0.192 17.7 10 Sprinkler 312 Overhead 91.94 5.6 0.1 9.2 7 0.165 15.1 7.3 Sprinkler 313 Overhead 91.94 5.6 0.1 9.2 7 0.173 15.9 8.1 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 314 Overhead 91.94 5.6 0.1 9.2 7 0.263 24.2 18.6 Sprinkler 316 Overhead 91.94 5.6 0.1 9.2 7 0.162 14.9 7.1 Sprinkler 318 Overhead 91.94 5.6 0.1 9.2 7 0.284 26.1 21.8 Sprinkler 319 Overhead 91.94 5.6 0.1 9.2 7 0.161 14.8 7 Sprinkler 321 Overhead 91.94 5.6 0.1 9.2 7 0.326 30 28.6 Sprinkler 322 Overhead 91.94 5.6 0.1 9.2 7 0.308 28.3 25.5 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 319 Overhead Sprinkler 5.6 14.8 91.94 7 7 7.17 HEAD Open 5.6 0.161 -4.4 9.2 316 Overhead Sprinkler 5.6 14.9 91.94 7.1 7 7.17 HEAD Open 5.7 0.162 -4.4 9.2 312 Overhead Sprinkler 5.6 15.1 91.94 7.3 7 7.17 HEAD Open 6 0.165 -4.4 9.2 308 Overhead Sprinkler 5.6 15.3 91.94 7.4 7 7.17 HEAD Open 6.1 0.166 -4.4 9.2 307 Overhead Sprinkler 5.6 15.3 91.94 7.4 7 7.17 HEAD Open 6.1 0.166 -4.4 9.2 301 Overhead Sprinkler 5.6 15.4 91.94 7.6 7 7.17 HEAD Open 6.2 0.168 -4.4 9.2 310 Overhead Sprinkler 5.6 15.4 91.94 7.6 7 7.17 HEAD Open 6.3 0.168 -4.4 9.2 302 Overhead Sprinkler 5.6 15.9 91.94 8 7 7.17 HEAD Open 6.7 0.172 -4.4 9.2 313 Overhead Sprinkler 5.6 15.9 91.94 8.1 7 7.17 HEAD Open 6.7 0.173 -4.4 9.2 311 Overhead Sprinkler 5.6 17.7 91.94 10 7 7.17 HEAD Open 8.5 0.192 -4.4 9.2 305 Overhead Sprinkler 5.6 18 91.94 10.3 7 7.17 HEAD Open 8.8 0.196 -4.4 9.2 304 Overhead Sprinkler 5.6 18.1 91.94 10.4 7 7.17 HEAD Open 8.9 0.197 -4.4 9.2 303 Overhead Sprinkler 5.6 18.9 91.94 11.4 7 7.17 HEAD Open 9.7 0.206 -4.4 9.2 306 Overhead Sprinkler 5.6 19 91.94 11.6 7 7.17 HEAD Open 9.8 0.207 -4.4 9.2 309 Overhead Sprinkler 5.6 21 91.94 14.1 7 7.17 HEAD Open 11.8 0.229 -4.4 9.2 314 Overhead Sprinkler 5.6 24.2 91.94 18.6 7 7.17 HEAD Open 15 0.263 -4.4 9.2 318 Overhead Sprinkler 5.6 26.1 91.94 21.8 7 6.5 HEAD Open 16.9 0.284 -4.1 9.2 322 Overhead Sprinkler 5.6 28.3 91.94 25.5 7 7.17 HEAD Open 19.1 0.308 -4.4 9.2 321 Overhead Sprinkler 5.6 30 91.94 28.6 7 7.17 HEAD Open 20.8 0.326 -4.4 9.2 0018 Node 7.5 7.17 NODE -4.4 0017 Node 7.8 7.17 NODE -4.4 0016 Node 8.6 7.17 NODE -4.4 0010 Node 12.2 7.17 NODE -4.4 0007 Node 17.6 6.5 NODE -4.1 0006 Node 17.6 6.5 1 NODE -4.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0012 Node 18.7 6.5 NODE -4.1 0013 Node 19.6 6.5 NODE -4.1 0021 Node 20.5 6.5 NODE -4.1 0022 Node 23 6.5 NODE -4.1 0046 Node 39.4 7.17 NODE -4.4 0048 Node 42.6 7.17 NODE -4.4 0089 Node 50.2 19.06 INODE -9.6 0042 Node 51.2 19.25 NODE -9.6 0096 Node 53 18.02 NODE -9.1 0938-0 Node 59.6 5.28 NODE -3.6 0938-I Node 60.6 4.14 INODE -3.1 0939-0 Node 61.5 2.09 NODE -2.2 0939-I Node 67.3 1.93 NODE -2.1 0940 Node 67.9 0.5 INODE -1.5 H1 Outside Hose 100 69.6 -3 HOSE 0 100 0943 Node 69.6 -3 NODE 0 0944-0 Node 70.1 -3 INODE 0 0944-I Node 70.2 -3 NODE 0 0945 Node 70.4 -3 NODE 0 wi Supply -459.3 70.6 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 319 7.17 5.6 14.8 1.5 1x(90 ell)=4.02 5.75 100 7 316 7.17 5.6 14.8 1.728 4.02 0.0092 0 9.77 0.1 316 7.17 5.6 14.9 1.5 lx(tee-Br)=8.05 4.28 100 7.1 0018 7.17 29.7 1.728 8.05 0.0333 0 12.33 0.4 0018 7.17 11.6 1.5 1.8 100 7.5 310 7.17 5.6 41.3 1.728 0 0.0613 0 1.8 0.1 310 7.17 5.6 15.4 1.5 1.31 100 7.6 0017 7.17 56.8 1.728 0 0.1104 0 1.31 0.1 0017 7.17 15.1 1.5 4.97 100 7.8 0016 7.17 71.9 1.728 0 0.1711 0 4.97 0.9 0016 7.17 15.9 1.5 5.43 100 8.6 311 7.17 5.6 87.8 1.728 0 0.2477 0 5.43 1.3 311 7.17 5.6 17.7 1.5 lx(tee-Br)=8.05 10.71 100 10 0013 6.5 105.5 1.728 2x(90 ell)=8.05 16.1 0.3478 0.3 26.81 9.3 0013 6.5 145.3 2 1.79 100 19.6 0021 6.5 250.8 2.203 0 0.5297 0 1.79 0.9 0021 6.5 24.2 2 3.97 100 20.5 0022 6.5 274.9 2.203 0 0.6282 0 3.97 2.5 0022 6.5 26.1 2 3x(90 ell)=14.59 7.84 100 23 0046 7.17 301.1 2.203 14.59 0.7433 -0.3 22.42 16.7 0046 7.17 58.3 2 3.16 100 39.4 0048 7.17 359.3 2.203 0 1.0314 0 3.16 3.3 0048 7.17 0 2.5 lx(tee-Br)=11.46 12.93 100 42.6 0089 19.06 359.3 2.705 2x(90 ell)=9.12 20.57 0.3796 -5.2 33.51 12.7 0089 19.06 -91.4 4 2x(90 ell)=13.32 90.09 100 50.2 0096 18.02 267.9 4.31 13.32 0.0228 0.5 103.4 2.4 0096 18.02 91.4 4 2x(90 ell)=13.32 13.85 100 53 0938-0 5.28 359.3 4.31 13.32 0.0393 5.5 27.17 1.1 0938-0 5.28 0 4 1.14 59.6 DPV-1 0938-I 4.14 359.3 0 0 0.3948 0.5 *** 1.14 0.5 0938-I 4.14 0 4 2.04 120 60.6 0939-0 2.09 359.3 4.31 0 0.028 0.9 2.041 1 0.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0939-0 2.09 0 4 0.17 61.5 Ames 0939-I 1.93 359.3 0 0 34.2337 0.1 Deringer 30 0.17 5.7 *** 0939-I 1.93 0 4 1.43 120 67.3 0940 0.5 359.3 4.31 0 0.028 0.6 1.43 0.0 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 67.9 0943 -3 359.3 6.4 34.91 0.0031 1.5 44.03 0.1 0943 -3 100 6 104.43 140 69.6 0944-0 -3 459.3 6.4 0 0.0048 0 104.43 0.5 0944-0 -3 0 6 0.88 70.1 Gate A2360 0944-I -3 459.3 0 0 0.1144 0 *** 0.88 0.1 0944-I -3 0 6 1x(tee-Br)=43.72 1.21 140 70.2 0945 -3 459.3 6.4 43.72 0.0048 0 44.93 0.2 0945 -3 0 8 124.91 140 70.4 W 1 -3 459.3 8.55 0 0.0012 0 124.91 0.1 W 1 70.6 Path No: 2 312 7.17 5.6 15.1 1 1x(tee-Br)=3.56 0.47 100 7.3 0017 7.17 15.1 1.049 3.56 0.1086 0 4.04 0.4 0017 7.8 Path No: 3 308 7.17 5.6 15.3 1.5 1x(tee-Br)=8.05 3.14 100 7.4 0018 7.17 11.6 1.728 8.05 0.0058 0 11.19 0.1 0018 7.5 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 308 7.17 5.6 15.3 1.5 8.3 100 7.4 307 7.17 5.6 3.7 1.728 0 0.0007 0 8.3 0 307 7.17 5.6 15.3 1.5 9.22 100 7.4 301 7.17 5.6 18.9 1.728 0 0.0145 0 9.22 0.1 301 7.17 5.6 15.4 1.5 1x(90 ell)=4.02 6.19 100 7.6 302 7.17 5.6 34.4 1.728 4.02 0.0436 0 10.22 0.4 302 7.17 5.6 15.9 1.5 2x(90 ell)=8.05 17.99 100 8 305 7.17 5.6 50.2 1.728 8.05 0.088 0 26.04 2.3 305 7.17 5.6 18 1.5 8 100 10.3 306 7.17 5.6 68.2 1.728 0 0.1551 0 8 1.2 306 7.17 5.6 19 1.5 lx(tee-Br)=8.05 7.59 100 11.6 0006 6.5 87.2 1.728 2x(90 ell)=8.05 16.1 0.2446 0.3 23.69 5.8 0006 6.5 37 2 7.13 100 17.6 0012 6.5 124.2 2.203 0 0.1443 0 7.13 1 0012 6.5 21 2 4.68 100 18.7 0013 6.5 145.3 2.203 0 0.1927 0 4.68 0.9 0013 19.6 Path No: 5 313 7.17 5.6 15.9 1 lx(tee-Br)=3.56 0.98 100 8.1 0016 7.17 15.9 1.049 3.56 0.1189 0 4.54 0.5 0016 8.6 Path No: 6 304 7.17 5.6 18.1 1 1x(90 ell)=1.43 10.13 100 10.4 0010 7.17 18.1 1.049 1.43 0.1508 0 11.55 1.7 0010 7.17 18.9 1 lx(tee-Br)=3.56 4.07 100 12.2 0007 6.5 37 1.049 1x(90 ell)=1.43 4.99 0.5676 0.3 9.061 1 5.1 0007 6.5 0 2 2.15 100 17.6 0006 6.5 37 2.203 0 0.0153 0 2.15 0.0 0006 17.6 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 7 303 7.17 5.6 18.9 1 lx(tee-Br)=3.56 1.13 100 11.4 0010 7.17 18.9 1.049 3.56 0.1638 0 4.69 0.8 0010 12.2 Path No: 8 309 7.17 5.6 21 1 lx(tee-Br)=3.56 14.89 100 14.1 0012 6.5 21 1.049 2x(90 ell)=2.85 6.42 0.1997 0.3 21.31 4.3 0012 18.7 Path No: 9 314 7.17 5.6 24.2 1 lx(tee-Br)=3.56 1.17 100 18.6 0021 6.5 24.2 1.049 1x(90 ell)=1.43 4.99 0.2582 0.3 6.16 1.6 0021 20.5 Path No: 10 318 6.5 5.6 26.1 1 lx(tee-Br)=3.56 0.5 100 21.8 0022 6.5 26.1 1.049 3.56 0.2985 0 4.06 1.2 0022 23 Path No: 11 322 7.17 5.6 28.3 1 9 100 25.5 321 7.17 5.6 28.3 1.049 0 0.3456 0 9 3.1 321 7.17 5.6 30 1 lx(tee-Br)=3.56 4.59 100 28.6 0046 7.17 58.3 1.049 3.56 1.3168 0 8.161 1 10.7 0046 39.4 Path No: 12 H1 -3 100 6 lx(tee-Br)=43.72 1.76 140 69.6 0943 -3 100 6.4 43.72 0.0003 0 45.48 0.0 0943 69.6 Path No: 13 0089 19.06 0 4 5x(90 ell)=33.29 296.04 100 50.2 0042 19.25 91.4 4.31 33.29 0.0031 -0.1 329.33 1 0042 19.25 0 4 lx(tee-Br)=16.69 385.05 100 51.2 0096 18.02 91.4 4.31 4x(90 ell)=26.63 43.33 0.0031 0.5 428.381 1.3 0096 53 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 30.25 ft/s occurs in the following pipe(s): (0048-0046) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 3; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 3; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 y 11.1 Q' 10.15 L 7 9.1 N 8.1 L. a 7.1 5.7 psi @ 359.3 gpm 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 15 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 3; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1100, 0-00 1.9 0.5 psi @ 359.3 gpm 0.9 0 0 0 0 0 0 0 0 0 0 o c o 0 c o c c c o I o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 3; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @ 459.3 gpm 0 o c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 16 i FIRE SPRINKLER PERMIT APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 Type of Permit: F] New Installation [] System Modification [] Phased Installation Property Address. 18520 67th Ave NE Suite No.: Project Valuation: 149,900 Lot#: Parcel ID No.: 31052200102000 Preferred Contact: ❑ Owner ❑Applicant ❑ Contractor Project Description: Burns to start at flange 12" AFF inside of riser room to provide code compliant NFPA13 system Owner Name: Mina Properties VII, LLC Phone No.: Email Address: Cell No.: Mailing Address: 1418 MarketSt City: Kirkland State: WA zip: 98033 Applicant Name: Audra Williams Phone No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: 425-223-6464 Mailing Address: PO Box 1110 City:Granite Falls State: WA Zip: 98252 Contractor Name: Burns Fire Protection Systems, Inc. Office No.: 360-691-2235 Email Address: audra@burnsfire.com Cell No.: 425-223-6464 Mailing Address: PO Box 1110 City: Granite Falls State: WA zip: 98252 L&I Contractor License Number: BURNSFP841 DU Expiration Date: 12-31-2023 SUBMITTAL REQUIREMENTS: Provide Information on All Equipment to be Installed Prior to Installation ELECTRONIC FILES OF THE FOLLOW: 0 Complete and Scaled Plans I] Hydraulic Calculations I] Equipment Specifications for Each Fire Sprinkler Permit Application 0 Specification Sheets ❑ Wiring Diagrams (Point to Point Wiring) ❑ Electrical Plans,if applicable FIRE SPRINKLER SYSTEMS (105.7.1, 105.7.4, 105.7.11) ** DEVICES include separate individual portions of a Fire Sprinkler System such as: Sprinklers Heads, Risers, Valves, Pull Stations, and other such devices. (Each piece is one device) PLAN REVIEW FEES Less than $5,000.00 = $100.00 $5,000.00 &over-based on project valuation (Plan Review Fee is 65%of project valuation as calculated per Table 4-1) REV11.2020 Page 1 of 3 REINSPECTION / PHASED INSTALLATION INSPECTIONS Submit Phasing Plan with Application - review and approval required REINSPECTION FEES SHALL BE PAID PRIOR TO INSPECTION FEE Reinspection/Phased Installation fee is charged per hour (1 hour minimum) $75.00 Hydrostatic Pressure Test(1 test included per permit) $150.00 Cover Inspection (1 cover inspection included per permit) $75.00 Fire Pump (1 fire pump inspection per permit) inspection requires 2 hours $150.00 ❑ TENANT IMPROVEMENT OR SYSTEM MODIFICATION (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1to2 $ 75.00 = $ 3 to 5 $125.00 = $ 6 to 10 $175.00 = $ 11 to 20 $225.00 = $ 21 to 40 $300.00 = $ 41 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $575.00 = $ > 300 $600.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = $600.00 + 1 $ 1 = $ Hydraulically Designed Systems Yes ❑ No ❑ Yes = Permit Fee x 2 $ PERMIT FEE SUBTOTAL $ ✓❑ NEW COMMERCIAL SYSTEM (NFPA 13/13R) Number of Devices" Device Fee Subtotal 1 to 100 $375.00 = $ 101 to 200 $475.00 = $ 201 to 300 $600.00 = $ > 300 $625.00 plus$50.00 per 100 additional devices(round up) Total Number of Devices = 433 $625.00 + 1 $100 = $ 725.00 Hydraulically Designed Systems Yes 0 / No ❑ Yes = Permit Fee x 2 $ 1450.00 PERMIT FEE SUBTOTAL $ 2175.00 ❑ RESIDENTIAL (NFPA 13D) Number of Devices" Device Fee Subtotal 1 to 10 $175.00 = $ 11 to 25 $225.00 = $ 26 + $275.00 = $ *NFPA 13D SYSTEM INSTALLED(NOT REQUIRED)Permit Fee Reduced 50% = $ PERMIT FEE SUBTOTAL $ REV2022 Page 2 of 3 ❑ HOOD SUPPRESSION SYSTEM Type of System No. of Units Cost per Unit Subtotal Pre-Engineered x $200.00 = $ Custom Engineered x $275.00 = $ PERMIT FEE SUBTOTAL $ ❑ STANDPIPE SYSTEM Type of Standpipe No. of Units Cost per Unit Subtotal Class I - new or existing x $150.00 = $ Class II - new or existing x $150.00 = $ PERMIT FEE SUBTOTAL $ ❑ FIRE PUMP Fire Pump x $300.00 each = $ PERMIT FEE SUBTOTAL $ ❑ SPRAY BOOTHS (105.7) &INDUSTRIAL OVENS (105.7.7) NOTE.SEPARATE SPRINKLER PERMIT REQUIRED Type of Booth No. of Units Cost per Unit Subtotal Pre-Engineered w/documents x $150.00 = $ Site-built or used w/o documents x $250.00 = $ Industrial Oven x $250.00 = $ PERMIT FEE SUBTOTAL $ Plan review fee due at time of submittal TOTAL PERMIT FEE $ 2175.00 PLAN REVIEW FEE $ 1918.24 Processing/Technology Fee $25.00 TOTAL $ 4093.24 I hereby certify that I am the ❑ Owner, ✓❑Applicant, ❑ Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington,and the City of Arlington. Signature Print Name Date SAVE PRINT REV2022 Page 3 of 3 Seismic Brace Report p . / Ack,Engineered Solutions Project Name Seattle Galvanizing Company APPROVAL STAMP MI Date 09/05/2023 ❑ Approved Address 18520 67th Ave NE Arlington, WA 98223 ❑ Approved as Noted - -- ❑ Not Approved WASHINGTON STATE ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , Remarks: David Yates 2605.0898-C Level , ' Burns Fire Protection Systems,Inc. I=F 2801bU 9/6/23 Expires: ; Signxture Date 12/31/23 Standard NFPA 13-2019 ................................ BRACE SUMMARY Drawing Seismic Design Brace Name Structure Brace Description Fastener Attachments Reference Load Lateral A FP2 450 Ibf. Horizontal Beam Flange Lateral Orientation 60'-90' 1 NPS Sch AF778 40 AF700-1/2" AF035-4 NPS x 1 NPS Longitudinal B FP2 157 IV. Horizontal Beam Flange Longitudinal Orientation 60°-90° 1 AF778 NPS Sch 40 AF700-1/2" AF730-4 NPS NOTE:Per NFPA 13-2019,all load capacities listed for fasteners installed in cracked concrete have been reduced based on the prying factors listed for ASC's swivel attachments.Prying factors for NFPA fastener orientations"A"through "I"may be found in ASC's individual product submittal at asc-es.com NFPA 13-2016 Product loads incorporate a minimum safety factor of 1.5.NFPA 13-2019 FM Product loads have been reduced to include a safety factor of 2.2 unless noted in the applicable product submittal. The products specified within this report are limited to the capability of the sway brace assembly alone to resist the calculated seismic force resulting from user input. Point loads applied to structural elements as a result of seismic forces are not evaluated by the software.The seismic load rating of the fastener attached to a structural element is determined by one of the following:NFPA 13,UL listing,FM Global approval,or other empirical testing. The review of the of the structural element(s)as a whole and/or the entire structure and its ability to resist the seismic load(s)is beyond the scope of these seismic calculations. ASC MAKES NO WARRANTIES,EXPRESS,IMPLIED,STATUTORY,OR OTHERWISE, WITH RESPECT TO THE SOFTWARE OR THE SEISMIC CALCULATIONS,AND ASC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 1 LATERAL A - SEISMIC BRACE CALCULATIONS Seismic Project Braces to Crane support beams Brace Name Lateral A Standard NFPA 13-2019 Drawing Reference FP2 Brace Type Lateral Approval Agency UL Listed STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS Structure I-Beam/Joist Model Size Load Rating Substrate Horizontal Beam Flange Structural Att. AF778 N/A 1,385 Ibf. Thickness 0.250 in. Swivel Att. AF700 1/2" 1,632 Ibf. Load Orientation Parallel to Beam Pipe Att. AF035 4 NPS x 1 NPS 1,632 Ibf. BRACE INFORMATION See Appendix A for alternate seismic brace attachments. Brace Member 1 NPS Sch 40 All seismic brace attachments manufactured byASC Engineered Solutions. Brace Length Max 7 ft 0 in Brace Angle 600 - 900 structure: Beam(By Others) Least Radius of Gyration 0.421 in. Fig.AF77s 1/r Ratio Max 200 01 Fig.AF700 Max Horizontal Load 1,604 Ibf. FASTENER INFORMATION Pipe Schedule 40 Service Fastener Name N/A Brace Pipe Fig.AF035 Net Vertical Reaction Forces do not need to be addressed per NFPA 13-2019. SPRINKLER SYSTEM LOAD CALCULATION (Fpw = CP*WP) CP = 0.602 AW Qty Line Description Pipe Diameter/Type Length Weight per ft Weight 1 Main Braced Pipe 4 NPS Eddy Flow 19.00 ft. 11.29 lb/ft. 214.51 lb. 2 Branch 1 Segment A 1 1/2 NPS Eddy Flow 76.00 ft. 2.86 lb/ft. 217.36 lb. Weakest Main Size Spacing Max Fpw Total System Weight 649.23 lb. 4 NPS Eddy Flow 20 ft. 1,544 Ibf. System Design Weight (WP) 747.00 lb. Horizontal Seismic Load (Fpw) 450 Ibf. 2 LONGITUDINAL B - SEISMIC BRACE CALCULATIONS Seismic Project Braces to Crane support beams Brace Name Longitudinal B Standard NFPA 13-2019 Drawing Reference FP2 Brace Type Longitudinal Approval Agency UL Listed STRUCTURE INFORMATION SEISMIC BRACE ATTACHMENTS Structure I-Beam/Joist Model Size Load Rating Substrate Horizontal Beam Flange Structural Att. AF778 N/A 1,385 Ibf. Thickness 0.250 in. Swivel Att. AF700 1/2" 1,632 Ibf. Load Orientation Perpendicular to Beam Pipe Att. AF730 4 NPS 1,632 Ibf. BRACE INFORMATION See Appendix A for alternate seismic brace attachments. Brace Member 1 NPS Sch 40 All seismic brace attachments manufactured byASC Engineered Solutions. Brace Length Max 7 ft 0 in Brace Angle 60' -90' _ Fig.AF778 Structure: Least Radius of Gyration 0.421 In. Beam (By Others) I/r Ratio Max 200 Fig.AF7°° Max Horizontal Load 1,604 Ibf. FASTENER INFORMATION Schedule 40 Fig.AF730 Brace Pipe Fastener Name N/A Service Pipe Net Vertical Reaction Forces do not need to be addressed per NFPA 13-2019. SPRINKLER SYSTEM LOAD CALCULATION (Fpw = Cp*Wp) Cp = 0.602 ;11&. M Qty Line Description Pipe Diameter/Type Length Weight per ft Weight 1 Main Braced Pipe 4 NPS Eddy Flow 20.00 ft. 11.29 Ib/ft. 225.80 lb. Total System Weight 225.80 lb. System Design Weight (Wp) 260.00 lb. Horizontal Seismic Load (Fpw) 157 Ibf. 3 Appendix A - Alternate Seismic Brace Attachments LATERAL A Structural Attachment Structural Structural Attach. Swivel Pipe Attachment Attach. Size Capacity AF778 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. AF735 4 NPS x 1 NPS 1,632 Ibf. AF778 1,385 Ibf. AF076 1/2" 11,515 Ibf. AF730 4 NPS 11,632 Ibf. AF720 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. AF720 1,385 Ibf. AF700 1/2" 1,632 Ibf. - AF720 1,385 Ibf. AF076 1/2" 1,515 Ibf. - AF087 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF087 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF087 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 649 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF086 649 Ibf. AF076 1/2" 11,515 Ibf. - AF086 649 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 649 Ibf. AF700 1/2" 11,632 Ibf. - AF086 649 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - LONGITUDINAL B Structural Attachment Structural Structural Attach. Capacity Swivel Pipe Attachment Attach. Size AF778 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - AF778 1,385 Ibf. AF076 1/2" 11,515 Ibf. - AF720 1,385 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. - AF720 1,385 Ibf. AF700 1/2" 1,632 Ibf. - AF720 1,385 Ibf. AF076 1/2" 1,515 Ibf. - AF087 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF087 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF087 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 1,186 Ibf. AF075 1 NPS x 1/2" 11,186 Ibf. - AF086 1,186 Ibf. AF076 1/2" 11,515 Ibf. - AF086 1,186 Ibf. AF077 1 NPS x 1/2" 1 588 Ibf. - AF086 1,186 Ibf. AF700 1/2" 11,632 Ibf. - AF086 1,186 Ibf. AF771 1 NPS x 1/2" 11,731 Ibf. 4 Appendix B - Enlarged Images LATERAL A Structure: Beam (By Others) Fig. AF77S 0 -- .J Fig. AF700 Schedule 40 Service Brace Pipe Pipe Fig. AF035 LONGITUDINAL B Fig. AF778 Structure. Beam (By Others) �\ Q `J Fig. AF700 Fig. AF730 Schedule 40 Brace Pipe \� Service Pipe 5 Appendix C - Cp Calculations BRACE CALCULATION DATA Brace Name Brace Ref Method CP SS Site Fa SDS Z H Lateral A FP2 A 0.602 1.280 Longitudinal B FP2 A 0.602 1.280 CALCULATION METHODS A CP calculated per NFPA 13-2019 Table 18.5.9.3 B CP entered by user C CP calculated per ASCE/SEI 7-16 per NFPA 13-2019 Section 18.5.9.4 Notes for Calculation Method C Per NFPA 13-2019, the following values are always assumed for aP,RP,and IP: aP RP IP 2.5 4.5 1.5 LEGEND EQUATIONS FPW Seismic Horizontal Design Force Fpu, = CpWp CP Seismic Coefficient per NFPA SS Short Period MCEr Spectral Response Acceleration Where:C 0.4RDs S 1 p Z * Hl Fa Site Coefficient. See Tables Below. p = 0.7 ` J P (1 +2 SpS Short Period Spectral Acceleration aP Component Amplification Factor. Taken as 2.5 for Fire Sprinkler Applications Where:SDs — 2�3 FaSs RP Component Response Modification Factor.Taken as 4.5 for Fire Sprinkler Applications IP Component Importance Factor.Taken as 1.5 for Fire Sprinkler Applications Cp,n = 0.7* 1.6SDSIp WP Component Operating Weight.Taken as the weight of the Fire Sprinkler System in the ZOI plus 15% Z Height in the structure where the component attaches to the structure. Height is Cp min = 0.7* 0.3SDSIp relative to the base of the structure and shall not be taken as less than 0 and shall not be larger than "H". H Average roof height of the structure relative to the base 6 SITE COEFFICIENT, FA PER ASCE/SEI 7-16 SS <_ 0.25 SS = 0.5 SS = 0.75 SS = 1 SS = 1.25 SS > 1.5 A 0.8 0.8 0.8 0.8 0.8 0.8 B 0.9 0.9 0.9 0.9 0.9 0.9 C 1.3 1.3 1.2 1.2 1.2 1.2 D 1.6 1.4 1.2 1.1 1 1 E 2.4 1.7 1.3 1.2 1.2 1.2 Use straight-line interpolation for intermediate values of S, SITE CLASSIFICATION PER ASCE/SEI 7-16 Site Class Ground Structure A Hard Rock B Rock C Very Dense Soil and Soft Rock D Stiff Soil E Soft Clay Soil 1' H i Z t GROUND BEFORE A SEISMIC EVENT DURING A SEISMIC EVENT (Exaggerated) 7 Appendix D - Bill of Materials Project Name Seattle Galvanizing Company Code Requirements NFPA 13-2019 Last Updated September 5, 2023 QUANTITY FIGURE NUMBER PRODUCT DESCRIPTION 0 Fastener 0 AF778 AF778 Universal Structural Brace Attachment AF778 0 AF700 1/2"AF700 Universal Swivel Attachment AF700-1/2" AF035 4 NIPS AF035 Model K Brace Clamp AF035-4 NIPS x 1 NIPS AF730 4 NIPS AF730 Longitudinal&Lateral Seismic Clamp AF730-4 NIPS 8 AFCONO Seismic Braces `11111�:p Engineered Solutions Universal Structural Brace Attachment Fig.AF778 Material Specifications Size Range: Flange Thickness: 1/8"to 1/4"thick Material Ductile Iron Casting with Carbon Steel Hardware A Finish H ❑ Plain ❑ ELectro-Galvanized per ASTM B633 Service A seismic structural attachment designed to NOW 1/2"Mounting Bolt attach to steel I-beams,flanges,and joists.The AF778 rigidly braces piping systems subjected to L horizontal and vertical seismic loads. J Approvals cULus Listed(ANSI/UL 203a),FM Approved(FM W 1950-13),&OSHPD(OPM-0351-13).Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. osr7pd cL us FM Features OPM-0351-13 LISTED APPROVED Shear Off Bolt x 2 The set screw provides a visual indication that proper installation has been achieved FIG.AF778 Dimensions and Weight May be installed anywhere a Fig 92 standard throat beam clamp may be installed Mounting Bolt A B L W H Weight In./mm In./mm In./mm In./mm In./mm Ibs/kg Ordering 16" 0.75 0.75 4.13 2.75 2.25 2.26 Specify figure number,finish,and description. (M12) 19.1 19.1 104.8 69.9 57.2 1.03 Installation Instructions AFCON.1 An ASC Engineered Solution Place the AF778 on a horizontal orvertical 3 Mount the AF700,AF771,orAF076 to the steel flange. 1/2"mounting bolt.The mounting bolt shall be installed wrench tight(typicaLLy finger 2 Hand tighten the set screws until they tight plus'/4 to 1/2 turns). contact the flange.Continue to torque the Notes: When installed with the AF700,AF771,or set screws until the heads break off. AF076,the Lowest Load rating at angle shall control the load rating of the assembly. PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-05.21 page 1 SS—SUB—AF778—v02 20230705 AFCONO Seismic Braces Engineered Solutions Universal Structural Brace Attachment Fig.AF778 FIG.AF778 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-90° Listed In./(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) Lbf/kN Horizontal Steel Flange and Parallel to Flange 0.1875-0.750 800 1131 1385 1600 Vertical Steel Flange Perpendicular to Flange (4.76-19.05) (3.56) (5.03) (6.16) (7.12) 1) Listed for installation with Fig.AF700,AF771,and AF076 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. Horizontal Steel Flange 4)Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. Seismic Load Parallel to Flange FIG.AF778 cULus Listing per UL 203a(ASD)for NFPA 13-2016 Editions or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 73.The 2076 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition.The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 203A,Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping,based upon a minimum safety factor of 1.5 in accordance with the earlier editions of NFPA 73.The load ratings based upon the 2076 or earlier editions of NFPA 13 should only be used where approved by the Authority HavingJurisdiction(AHJ). Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-90° Listed nd(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) LVAN 0.1875-0.249 500 707 865 1000 Horizontal Steel Flange (4.76-6.32) (2.22) (3.15) (3.85) (4.45) Seismic Load Perpendicularto Flange Horizontal Steel Flange and Parallel to Flange 0.250-0.499 800 1131 1385 1600 Vertical Steel Flange Perpendicular to Flange (6.35-12.67) (3.56) (5.03) (6.16) (7.12) OO OO 0.500-0.750 1007 1425 1744 2015 (12.70-19.05) (4.48) (6.34) (7.76) (8.96) Q 1) Listed for installation with Fig.AF700&AF771 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2016 Table 9.3.5.2.3. Oo 4)Minimum safety factor oft.5in accordance with NFPA13-2016 Section A.9.3.5.2.3. FIG.AF778 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Structure Load Orientation Flange Thickness 30°-44° 45°-59° 60°-74° 75°-90° Vertical Steel Flange In./(mm) Lbf/(kN) Lbf/(kN) Lbf/(kN) Lbf/kN Seismic Load Parallel to Flange Parallel to Flange 1280 1840 2210 2470 Horizontal Steel Flange (5.69) (8.18) (9.83) (10.99) Perpendicular to Flange 1570 1490 1040 1150 0.125-0.750 (6.98) (6.63) (4.63) (5.12) (3.18-19.05) 870 1440 1230 1360 Parallel to Flange O Vertical Steel Flange (3.87) (6.41) (5.47) (6.05) Perpendicular to Flange 1038 2260 2490 2750 (4.58) (10.05) (11.08) (12.23) 1) Listed for installation with Fig.AF700&AF771 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA13-2019 Table 18.5.2.3. 4) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA13-2019 Section A.18.5.2.3,multiply load ratings by a factor of 0.68. Vertical Steel Flange 5) To convert toLRFD Load Ratings,ASD Load Ratings may bemuLtipliedbya factor of1.5 Seismic Load PerpendiculartoFlange Notes: ASC Engineered SolutionsTm brand bracing components are designed to be compatible ONLYwith other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly.Updated UL Listing information may be viewed at www.uL.com and updated FM approval information may be viewed ® © © at www.approvaLguide.com. Disclaimer: asc-es.com ASC Engineered SolutionsTm does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not Building connections that last' manufactured or sold by ASC.In no event shall ASC be liable for any incidental,direct,consequential,special or indirect damages or Lost profits where non-ASC bracing components have been,or are used. Sells Brace®Seismic Fire Protection Design Tool.may be accessed at www.seisbrace.com SS-03.22 page 2 SS-SUB-AF778-v0220230705 AFCONO Seismic Braces Engineered Solutions Universal Swivel Attachment Fig.AF700 Material Specifications Size Range Brace Member:See Table Anchors:1h"-1/4"(M12—M18) Material Ductile Iron with Carbon Steel Hardware Finish ❑ Plain o, ❑ ELectro-Galvanized perASTM B633 r Service A seismic swivel attachment designed to connect a brace member to the building structure or to a seismic structural attachment.The AF700 rigidly € r braces piping systems subjected to horizontal and vertical seismic Loads. Approvals cLJLus Listed(ANSI/UL 203a)),FM Approved(FM c uL us Fm 1950-13),&FM Tested(FM 1950-16).FM Tested LISTED APPROVED (ANSI/FM 1950-16).Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Features • The set screw provides a visual indication that proper installation has been achieved OEliminates brace member eccentricity by T—Ac concentrically Loading T'and 11/4"brace pipes + Ordering Specify figure number,fastener size,finish and D description. AX Y Disclaimer: L ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shaLL ASC be liable FIG.AF700 Dimensions and Weight for any incidental,direct,consequential,special or indirect A B C D L X Y Weight damages or Lost profits where non-ASC bracing components have been,or are used. In./mm In./mm In./mm In./mm In./mm In./mm In./mm Ibs/kgs Seis Brace'Seismic Fire Protection Design Tool maybe 1.40 1.983 1.400 1.280 6.40 2.80 1.91 2.25 accessed at www.seisbrace.com 35.56 50.37 35.56 32.51 162.6 71.1 48.5 1.02 Notes: ASC Engineered SolutionsTI brand bracing components are designed to be compatible ONLY with other ���0� ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL Listing information may be viewed at www.ut.com and updated FM approval information may be viewed at www.approvaLguide.com. — An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: submittal Date: September 5,2023 Notes 1: Notes 2: SS-05.21 page 1 SS-SUB-AF700-vO2 20220408 AFCONO Seismic Braces Engineered Solutions Universal Swivel Attachment Fig.AF700 FIG.AF700 cULus Listing per ANSIML 203a(ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle VA4 30"-44" 45°-59° 60°-90' Listed 1 2" 'h"-W 942lbf 1333Ibf 1632Ibf 1885lbf Sch 40 Pipe(DN25-DN50) (M12-M18) (4.19 kN) (5.93 kN) (7.26 kN) (8.38 kN) 1) Load ratings may apply to NPFA 13 fastener orientations A,B,C,D,E,F,G,H,or I. 2) Brace Angles are determined from Vertical. 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) See table below for listed brace members. 5) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. NFPA 13 Orientations A,B,or C FIG.AF700 FM Approved(Listing)per FM 1950-13(ASD) Brace Member Fastener Size Horizontal Load Rating at Brace Angle 30°-44° 45°-59° 60°-74' 74'-90° 1`2" Y2"-3/4' 1780lbf 2510IV 3080lbf 3440lbf O Sch 40 Pipe (M12-M18) (7.92 kN) (11.17 kN) (13.70 kN) (15.30 kN) (DN25-DN50) 1) Load ratings may apply to NPFA 13 fastener orientations A,B,C,D,E,F,G,H,or I. 2) Brace Angles are determined from Vertical. 3) Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 TabLe 18.5.2.3. 4) See table below for listed brace members. 5) Minimum safety factor oft.5in accordance with NFPA13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply Load ratings by a factor of 0.68. 6)To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. NFPA13 Orientations D,E,or F FIG.AF700 FM Listed,Approved&Tested Brace Members Brace Member Brace Size Standard(or Equivalent) UL FM Sch.40 NPS Pipe 1",11ra",1 Y2",2" ASTM A53,Al06,A135,or A795 ✓ ✓ O DN25 KS S 3562 Sch.40 Metric Pipe ✓ ✓ DN32 EN10255H ✓ DN40 GB/T 3091 ✓ Metric Pipe DN50 JIS G3454 ✓ FIG AF700 Horizontal Prying Factors(Pr)Per NFPA 13:Angles(Deg) Fastener Orientation A B c D E F G H I Brace Angle 30°-44° 45°-59° 60°-90° 30°-44° 45°-59° 60°-90° 30°-44° 45°-59° 60°-90° NFPA 13 Orientations G, H,or I AF700 2.55 1.09 0.91 1.41 1.45 2.00 1.83 1.29 1.06 AF700 w/Metal Deck' 2.55 1.09 1.14 - - - - - - AF700 w/Metal Deck 2.75 1.11 1.14 - - - - - - 1) Prying factors reflect the basepLate`B"dimension overhanging the edge of the metal deck.Used for DeWaLt [moo anchor Loads. 2) Prying factors reflect the baseplate"A"or"B"dimension overhanging the edge of the metal deck.Used for asc-es.com NFPA&HiLti anchor Loads. .I 3) Prying Factors calculated in accordance with NFPA13-2019 Section A.18.5.12.2. BUILding connections that lat Last' SS-05.21 page 2 SS-SUB-AF700-v0220220408 AFCONO Seismic Braces MC. P / Engineered Solutions Universal Swivel Attachment Fig.AF700 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly up to the fastener or the related seismic structural attachment and connect through the mounting hole. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the range specified. Notes:The cross bolt should be hand tight.Forvisual inspection,at least one thread should be exposed. Method 2 - Connection to Structure First Connect the AF700 to the fastener or the related seismic structural attachment. 2 Tighten per the fastener or structural attachment specifications. 3 Slide the brace member over the lowerjaw until it contacts the back wall. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 5 Rotate the brace member until the brace angle is within the specified range. Notes:The cross bolt should be hand tight.Forvisual inspection,at least one thread should be exposed.. Structural Attachments,Anchors,&Fasteners Listed,Approved,&Tested with the AF700 Structural Attachment Structure AF085 Steel Joist(Top Chord) AF086 Horizontal Steel Flange(I-Beam Bottom Flange) AF772 Horizontal Steel Flange(I-Beam Bottom Flange) Horizontal Steel Flange(I-Beam Top or Bottom Flange) AF778 C-Channel(Top or Bottom Flange) Vertical Flange of a Joist(Top Chord) AF779 All Structures with the Applicable Approved Anchor or Fastener DeWalt Cracked Concrete Power-Stud®+SD1 Cracked Concrete Filled Metal Deck DeWalt Cracked Concrete Power-Stud®+SD2 Cracked Concrete Filled Metal Deck DeWalt Cracked Concrete Wood-Knocker®I I+ DeWalt Bang-It°+ Cracked Concrete Filled Metal Deck DeWalt DDI+' Cracked Concrete Filled Metal Deck Cracked Concrete [moo Anchors&Fasteners Cracked Concrete Filled Metal Deck Per NFPA 13 Steel asc-es.com Wood Saw Lumber or Glue-Laminated Timbers Building connections that last" SS-05.21 page 3 SS-SUB-AF700-4220220408 AFCONO Seismic Braces kttp Engineered Solutions Model K Lateral Sway Brace Fig.AF035 Material Specifications Size Range: Service Pipe Size:T'-12" Brace Member:T'-2" Material r Ductile Iron Casting with Carbon Steel Strap and Hardware Finish ❑ Plain ❑ Electro-Galvanized Service ®r' A seismic lateral brace designed to connect a brace member to the service pipe.The AF035 rigidly braces steel and CPVC piping systems subjected to horizontal and vertical seismic Loads. C U� US FM Approvals LISTED APPROVED cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).Complies with NFPA 13,ASCE 7, IBC,&MSS SP-127 bracing requirements. Features • The set screw provides a visual indication that proper installation has been achieved • Rounded edge design eliminates potential for abrasion of CPVC pipe Patents No.7,516,922,No.7,523,895 t ° Ordering O Specify figure number,service pipe size,brace size,finish,and description. o 1"(DN25)to 3"(DN80)Service Pipe 4"(DN100)to 12"Service Pipe AFCON® An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-04.21 page 1 SS-SUB-AF035-v03 20220408 / • © Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035:Weight Per Size Brace Member Size Service Pipe Size 1"(DN25) 1%"(DN32) 1%"(DN40) 2"(DN50) 1 1.60lbs 1.80lbs 2.00lbs 2.28lbs (DN25) 1'�4" 1.68 lbs 1.88 lbs 2.08 lbs 2.36 lbs (DN32) 1/z 1.64 lbs 1.84 lbs 2.04 lbs 2.32 lbs (DN40) 2 1.88lbs 2.08lbs 2.28lbs 2.56lbs (DN50) 21h" 1.90lbs 2.10lbs 2.30lbs 2.58lbs DN65 2.00lbs 2.20lbs 2.40lbs 2.68lbs 3 2.10lbs 2.30lbs 2.50lbs 2.78lbs (DN80) 4 2.18lbs 3.38lbs 3.58lbs 3.76lbs (DN100) 5 3.40lbs 3.60lbs 3.80lbs 4.08lbs (DN125) DN150 3.80lbs 4.00lbs 4.20lbs 4.48lbs 6" 3.90lbs 4.10lbs 4.30lbs 4.58lbs DN200 4.70lbs 4.90lbs 5.10lbs 5.38lbs 8" 4.80lbs 5.00lbs 5.20lbs 5.48lbs 10" 5.60lbs 5.80lbs 6.00lbs 6.28lbs 12" 6.16lbs 6.36lbs 6.56lbs 6.84lbs ®©o asc-es.com Building connections that last" SS-04.21 page 2 SS-SUB-AF035-4320220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 cULus Listing per ANSI/UL 203a(ASD) Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service Pipe Size 30°-44° 45°-59° 60°-90° Listed Pipe Pipe IVAN VAN YAN VAN V,Aa Sch.10 Mega-Thread 1" Sch.40 MLT/GL (DN25) CPVC Eddy Thread Metric Pipe EZ-Thread Mega-Flow Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Mega-Flow Lateral Application Sch.10 MLT/GL 11/2 Sch.40 Mega-Thread (DN40) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 625 884 1082 1250 2.78 3.93 4.81 5.56 Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega-Thread (DN50) CPVC Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Sch.10 Mega-Flow 21/2" Sch.40 Eddy Flow CPVC Fire-Flo DN65 Metric Pipe - Lateral Appllcatlon Sch.10 Mega Flow 3" Sch. Eddy Flow (DN80) CPVCC Fire-Flo O Metric Pipe 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 5„ Sch.10 O (DN125) Sch.40 - Metric Pipe DN150 Metric Pipe - 942 1333 1632 1885 Sch.10 4.19 5.93 7.26 8.38 6 Sch.40 Mega-Flow 0 DN200 Metric Pipe - 8„ 0.188"wall _ Sch.40 0.1ch.wall Riser Application 10" 0.188" 12" 0.188"wall _ 1125 1591 1948 2250 Sch.40 5.00 7.08 8.67 10.01 1) Brace Angles are determined from Vertical. 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. 4) See table below for UL listed specialty pipes&UL Listed metric service pipes. 5) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for Listed asc-es.com brace members. Building connections that last" 6) Minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. SS-04.21 page 3 SS-SUB-AF035-v0320220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 cULus Listing Per UL 203a(ASD)For NFPA 13-2016 Editions Or Earlier UL's current Listings are predicated on installation in accordance with the latest edition of NFPA 13.The 2076 and earlier editions of NFPA 13 referenced a minimum safety factor of 1.5 for the load rating as compared to 2.2 for the current edition.The load ratings noted in this table are consistent with the historical cULus Listings that were evaluated to the requirements of UL 2O3A,Outline of Investigation for Sway Brace Devices for Fire Sprinkler System Piping based upon a minimum safety factor of 7.5 in accordance with the earlier editions of NFPA 73. The load ratings based upon the 2016 or earlier editions of NFPA 13 should only be used where approved by the Authority Having Jurisdiction(AHJ). Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Pipe Pipe Ibf/kN Ibf/kN Ibf/kN Ibf/kN Sch.10 Mega-Thread 1 Sch 40 MLT/GL (DN25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow Lateral Application Sch.10 MLT/GL 1° Sch 40 Mega-Thread (DN32) Metric Pipe Eddy Flow Eddy Thread EZ-Thread Mega-Flow MLT/GL 11/2'. Sch.10 Mega-Thread (DN40) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread EThread Fire-Flo Latera[App llcation Fire-Flo 1382 1955 2393 2765 Sch.10 Mega-Flow 6.15 8.70 10.65 1 b.. 21h" Sch.40 Eddy Flow Metric Pipe Fire-Flo O DN65 Metric Pipe - 3" Sch.10 Mega-Flow (DN80) Sch.40 Eddy Flow Metric Pipe Fire-Flo 4" Sch.10 Mega-Flow O (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 5" Sch.10 (DN125) Sch.40 - Metric Pipe 0 DN150 Metric Pipe - 6„ Sch.10 Sch.40 Mega Flow DN200 Metric Pipe - Riser Application 8" 0.188"Wall _ Sch.40 101, 0.188"Wall _ Sch.40 12" 0.188"Wall _ 1870 2644 3238 3740 Sch.40 8.32 11.77 14.40 16.64 1) Brace Angles are determined from Vertical. [moo 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. 3) Listed Load ratings reduced for angle ranges in accordance with NFPA 13-2016 Section A.93.5.23. asc-es.com 4) See table below for UL Listed specialty pipes&UL Listed metric service pipes. 5) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for Listed brace members. BUILdIng connections that Last" 6) Minimum safety factor of 2.2 in accordance with NFPA 13-2016 Section A.9.3.5.23. SS-03.22 page 4 SS-SUB-AF035-v03 20220408 AFCONO Seismic Braces Engineered Solutions Model K Lateral Sway Brace Fig.AF035 FIG.AF035 FM Approved(Listing)per FM 1950-13(ASD) Standard Speicalty Horizontal Load Rating at Brace Angle Service Service Service VAO Pipe Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Sch.10 Mega-Thread 1 Sch.40 MLT/GL (DN25) Metric Pipe Eddy Thread EZ-Thread Mega-Flow 1660 2350 2880 3210 MLT/GL 7.38 10.45 12.81 14.28 114° Sch. Mega-Thread (DN32) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Lateral Application Mega-Flow MLT/GL 11r2 Sch.10 Mega-Thread (DN40) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo 1540 2170 2660 2970 Mega-Flow 6.85 9.65 11.83 13.21 MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread EZ-Thread Fire-Flo Sch.10 Mega-Flow 2h Sch.40 Eddy Flow Fire-Flo Lateral Application DN65 Metric Pipe - 1270 1790 2200 2450 5.65 7.96 9.79 10.90 O 3„ Sch.10 Mega-Flow (DN80) Sch.40 Eddy Flow Metric Pipe Fire-Flo 4" Sch.10 Mega-Flow O 1020 1450 1770 1980 (DN100) Sch.40 Eddy Flow 4.54 6.45 7.87 8.81 Metric Pipe Fire-Flo 5„ Sch.10 (DN125) Sch.40 - Metric Pipe O 860 1220 1490 1660 DN150 Metric Pipe - 3.83 5.43 6.63 7.38 6" Sch.10 Mega-Flow Sch.40 Riser Application DN200 Metric Pipe - 540 770 950 1060 8„ 0.188"Wall 2.40 3.43 4.23 4.72 Sch.40 1) Brace Angles are determined from Vertical. 2) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© 3) See table below for FM listed specialty pipes&FM Listed metric service pipes. 4) Load Ratings reflect 1"(DN25)-2"(DN50)brace members.See table below for listed brace members. 5) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings asc-es.com above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply Load ratings by a factor of 0.68. 5)To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. BUILding connections that Last" SS-04.21 page 5 SS-SUB-AF035-v0320220408 AFCONO Seismic Braces xcwk, / Engineered Solutions Model K Lateral Sway Brace Fig.AF035 Place the AF035 over the service pipe to be braced. Z Insert the brace member through the cast hoop ends. The end of the brace pipe shall extend at least 1"(25.4 mm)past the cast hoop ends. 3 Hand tighten the set screws until they contact the brace member. Continue to torque the set screws until the heads bottom out on the cast hoop ends. 4 Tighten per the fastener or structural attachment specifications. 5 Ensure the brace angle is within the specified range. Notes:The brace member may be installed above or below the service pipe. 1"Min. ❑ ❑ Set Screw Installation 10i FIG.AF035 cULus Listed&FM Approved Brace Members Brace Member Brace Size Standard(or Equivalent) UL FM Sch.40 NPS Pipe 1",1 Y4",1'h",2" ASTM A53,Al06,Al35,or A795 ✓ ✓ KS S 3562 ✓ ✓ Sch.40 Metric Pipe DN25 EN10255H ✓ DN32 DN40 GB/T 3091 ✓ DN50 Metric Pipe JIS G3454 ✓ FIG.AF035 cULus Listed&FM Approved Metric Service Pipes Service Pipe Standard(or Equivalent) Service Pipe Size UL FM KS D 3507 V ✓ KS D 3537 DN25 KS D 3562 DN32 ✓ ✓ Sch.40 DN40 GB/T 3091 DN50 ✓ GB/T 3092 DN65 JIS G3452 DN80 ✓ DN100 EN 10255M DN125 ✓ DN150 EN 10255H DN200 ✓ Notes: ASC Engineered Solutions""brand bracing components are designed to be compatible ONLY with other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly.Updated UL Listing information may ®© be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. Disclaimer: asc-es.com ASC Engineered Solutions does not provide any warranties and specifically disclaims any Liability whatsoever with respect to ASC bracing products and components that are used in combination with products,parts or systems not Buildin6 connections that last' manufactured or sold by ASC.In no event shall ASC be Liable for any incidental,direct,consequential,special or indirect b damages or Lost profits where non-ASC bracing components have been,or are used. Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com SS-04.21 page 6 SS-SUB-AF035-v0320220408 / • © Seismic Braces V `11111�:p Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Material Specifications Size Range Service Pipe Size:T'-12,DN25-DN100 - Material Carbon Steel Clamp and Hardware.Ductile Iron Brace Member Attachment Fitting. r Finish s ❑ Plain ❑ Clamp:Hot Dipped Galvanized per ASTM A153 cL us Fnn ❑ Brace Member Attachment Fitting: LISTED APPROVED Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and lateral brace clamp designed to connect a piping system to a brace O O member.The AF730 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).FM Tested(ANSI/FM 1950-16). FIG.AF730 Dimensions and Weight Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Size A B Y Weight Features In./mm In./mm In./mm Ibs/kgs Torque offset screw and nuts provide a visual 1"(DN25) 7.6 193 2.49 1.13 indication that the desired installation torque 11/2"(DN32) 8.0 203 2.55 1.13 values have been achieved. 11/2" DN40 8.2 208 2.64 1.20 Ordering ( ) Specify figure number,service pipe size,finish, 2"(DN50) 8.7 221 2.78 1.26 and description. 21/2" 9.2 234 2.92 1.32 DiscLaimer: ASC Engineered Solutions does not provide any warranties 3"(DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4"(1)N100) 10.8 274 3.38 1.53 are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been,or are used. 8" 15.2 386 6.40 2.90 Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered Solutions*"brand bracing components are designed to be compatible ONLY with other AFCON, ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: Seattle Galvanizing Company ❑Approved Address: 18520 67th Ave NE,Arlington,WA 98223 ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: September 5,2023 Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service V.,O `11111�:p Size Pipe Pipe 30°-44° 45`-59` 60°-90° Listed 30`-44` 45°-59° 60°-90° Listed VAN VAN VAN IVAN IVAN VAN VAN VAN Sch.A Mega-Thread 1 Sch.40 MLT/GL 340 480 588 680 340 480 588 680 (DN25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 EZ-Thread Mega-Flow O Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) Metric Pipe EEddd Flow Longitudinal Application ThreaEZ-Thread Mega-Flow MLT/GL 11/2 Sch.10 Mega-Thread Sch.40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo 0 EZ-Thread Mega-Flow 21/2 Sch.10 Eddy Flow Sch.40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 Sch.10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 3 Sch.40 Eddy Flow (DN80) Metric Pipe Fire-Flo 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 51, Sch.10 _ Sch.40 Sch.10 942 1333 1632 1885 942 1333 1632 1885 6 Sch.40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch.10 8" 0.188"Wall - Riser Application Sch.40 10" 0.188"Wall _ Sch.40 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes&UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA13-2019 Section A.18.5.2.3. BUILdIng connections that Last' All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service VAO %IIZ:P Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN bf/kN Sch.10 Mega-Thread V Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow 0 Sch.10 MLT/GL 1Y4" Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Lon itudinatA EZ-Thread g ppllcatlon Mega-Flow Sch.10 MLT/GL 1v2" Sch.40 Mega Thread Y 800 650 790 1800 1790 2530 3100 3460 ( ) DN40 Metric Pipe Eddy Flow Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega Thread Y 830 990 1190 1620 1820 2580 3160 3530 ( ) DN50 Metric Pipe Eddy Flow Eddy Thread 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Fire-Flo EZ-Thread 2h' Sch.10 Edda Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Sch.10 Mega-Flow Lateral Application 3" Sch.40 EddyFlow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 4" Sch.10 Mega-Flow 760 1040 1270 1400 1260 1790 2190 2440 (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 51, Sch.10 _ 890 1230 1410 1550 1260 1790 2190 2440 Sch.40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 6„ Sch.10 Mega-Flow 700 940 1140 1310 950 1340 1640 1830 Sch.40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 8„ 0.188"Wall _ 990 1130 1360 1520 1540 2170 2660 2970 Sch.40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 10" 0.188"Wall _ 1020 850 1000 1100 1700 2410 2950 3290 Riser Application Sch.40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 12" 0.188"Wall _ 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. [moo Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of1.5. BUILdIng connections that Last" See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces rlrs:) / Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe.Unbolt the back nut&bolt and rotate the clamp halves over the service pipe.Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut&bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 3 Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. FIG.AF730 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1",1 Y,",1 v2",2" ASTM A53,Al 06,Al 35,or ✓ ✓ NIPS Pipe A795 Sch.40 Metric Pipe KS D 3562 ✓ ✓ DN25,DN32, EN10255H ✓ Metric Pipe DN40,DN50 GB/T3091 ✓ AS G3454 ✓ FIG.AF730 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 ✓ ✓ KS D 3537 KS D 3562 ✓ ✓ Sch.40 G B/T 3091 ✓ GB/T 3092 DN25,DN32,DN40, JIS G3452 DN50,DN 80,DN100 ✓ EN10255M asc-es.com EN 10255H Building connections that last" ss-07.20 page 4 SS-SUB-AF730-v04 20221228 Burns Fire Protection Systems, Inc. P.O. Box 1110 Granite Falls, WA 98252 PH: (425) 388-0124 Seattle Galvanizing Co 18520 67th Ave NE Arlington, WA 98223 Item No DESCRIPTION MANUFACTURER MFG. NO. FINISH REMARKS Air Compressor General Air Maintenance Device Tyco Wall Mount FDC FPPI 4 x 2.5 x 2.5 Hose Valve FPPI Backflow Preventor Ames Derringer 30 Check Valve Tyco CV-1 Blue/BLK Electric Bell Potter Red Dry Valve Tyco DPV-1 Sprinkler Head Tyco TY3131 WH Sprinkler Head Tyco TY3151 Chr Sprinkler Head Tyco TY3351 WH Sprinkler Head Tyco TY3331 WH Storage Cabinet FPPI Red Steel Pipe Bull Moose Eddy Flow Steel Pipe Bull Moose Sched 10/40 Blk Sammy Screw All Buildex Hangers Caddy Seismic Bracing Caddy Sway Brace Caddy Grooved Coupling Victaulic 009H Orange Grooved Fitting Victaulic Orange Mech Tee Tyco 730 Orange Threaded Fittings Shurjoint Blk tqC0 Fire & Building Products Technical Services: Tel: (800) 381-9312/Fax: (800) 791-5500 Series TY-B — 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General standard corrosion tests of the appli- cable approval agencies,the testing is Description not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be The Series TY-B, 5.6 and 8.0 K-factor consulted with respect to the suitability Upright and Pendent Intermediate of these coatings for any given corro- Level Sprinklers described in this data sive environment.The effects of ambi- sheet are automatic sprinklers of the ent temperature, concentration of "standard response" 5 mm frangible chemicals, and gas/chemical velocity, bulb type. They are "standard spray" should be considered, as a minimum, -_ - sprinklers intended for use in fire sprin- along with the corrosive nature of the kler systems designed in accordance chemical to which the sprinklers will be with the standard installation rules rec- exposed. ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright Sprinklers WARNINGS it produce a hemispherical water distri- The Series TY-B Sprinklers described bution pattern below the deflector. herein must be installed and main- tained in compliance with this docu- Intermediate Level Sprinklers are pri- ment, as well as with the applicable marily designed for use in rack storage standards of the National Fire Protec- sprinkler systems where their ther- tion Association, in addition to the mally sensitive elements must be standards of any other authorities hav- shielded from the water spray of higher ing jurisdiction. Failure to do so may elevation sprinklers that could operate impair the performance of these de- r _ earlier during afire.Intermediate Level vices. Sprinklers are also used in other appli- cations such as beneath open gridded The owner is responsible for maintain- catwalks. ing their fire protection system and de- vices in proper operating condition. Corrosion resistant coatings, where The installing contractor or sprinkler Technical applicable, are utilized to extend the manufacturer should be contacted life of copper alloy sprinklers beyond with any questions. Data that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- Approvals tant coated sprinklers have passed the 11llodel/Sprinkler UL and C-UL Listed. FM and NYC Approved. Identification (Refer to Table A for complete approval information including corrosion resis- IMPORTANT tant status.) Y Always refer to Technical Data umbers Sheet TFP700 for the "INSTALLER Maximum Working Pressure WARNING" that provides cautions TY3153- Upright 5.6K, 1/2"NPT 175 psi (12,1 bar) with respect to handling and instal- TY3251 - Pendent 5.6K, 1/2"NPT Discharge Coefficient TY4153- Upright 8.OK,3/4"NPT g a lation of sprinkler systems and com TY4251 - Pendent 8.OK,3/4"NPT K=5.6 GPM/psis/2 (80,6 LPM/bars/2) 0 ponents. Improper handling and in- K=8.0 GPM/psil/2(115,2 LPM/bars/2) 2 stallation can permanently damage a sprinkler system or its compo- Temperature Ratings nents and cause the sprinkler to fail Refer to Table A o to operate in a fire situation or cause Finishes a it to operate prematurely. Sprinkler: Refer to Table A o Page 1 of 6 JANUARY, 2005 TFP351 Page 2 of 6 TFP351 7/16" (11,1 mm) 1/2"** 3-1/2" (88,9 mm) DIA, NOMINAL MAKE-IN NPT SHIELD O-RING SCREW lik/ UPRIGHT 7/16" 2 3/16" SHIELD* (11,1 mm) 2-3/8" (55,6 mm) MODEL S2 WRENCHING NOMINAL (60,3 mm) SHIELD FLATS MAKE-IN WRENCHING 1 FLATS 1 3-1/2" (88,9 mm) DIA, 1/2"** NPT PENDENT UPRIGHT (FIELD ASSEMBLED-SEE INSTALLATION SECTION) (FACTORY ASSEMBLED) * Temperature rating is indicated on the deflector, shield, or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY3153)AND PENDENT(TY3251)SPRINKLERS INTERMEDIATE LEVEL SPRINKLERS, 5.6 K-FACTOR, 112 INCH NPT 1/2" (12,7 mm) 3/4"** 3-1/2" (88,9 mm) DIA, NOMINAL MAKE-IN NPT SHIELD O-RING SCREW 2 5/16" UPRIGHT 1/2" (58,7 mm) MODEL S2 WRENCHING SHIELD* (12,7 mm) 2-7/16" NOMINAL (61,9 mm) SHIELD FLATS MAKE-IN WRENCHING 1 FLATS 1 3-1/2" (88,9 mm) DIA, 3/4"** PENDENT NPT UPRIGHT (FIELD ASSEMBLED-SEE INSTALLATION SECTION) (FACTORY ASSEMBLED) * Temperature rating is indicated on the deflector,shield,or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT(TY4153)AND PENDENT(TY4251)SPRINKLERS INTERMEDIATE LEVEL SPRINKLERS, 8.0 K-FACTOR, 314 INCH NPT TFP351 Page 3 of 6 SPRINKLER FINISH(See Note 5) K TYPE TEMP. BULB NATURAL LEAD WAX WAX OVER LIQUID BRASS*** COATED COATED LEAD COATED 135°F/57°C Orange UPRIGHT 155°F/68°C Red 5.6 (TY3153) 1,2,3,4 1,2,3,4 1,2,3,4 1,2,3,4 1/2" 175°F/79°C Yellow NPT 200°F/93°C Green 286°F/141°C Blue 1**,2",3**,4" 1",2**,3",4" 360°F/182°C Mauve N/A 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3251) 1,2.3,4 N/A 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve 135°F/57°C Orange UPRIGHT 155°F/68°C Red 80 (TY4153) 1,2.3,4 1,2.3,4 1,2.3,4 1,2,3,4 3/4" 175°F/79°C Yellow NPT 200°F/93°C Green 286°F/141°C Blue 1",2",3",4" 1",2",3",4" 360°F/182°C Mauve N/A 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4251) 1,2,3,4 N/A 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve NOTES: 1.Listed by Underwriters Laboratories, Inc.(UL). 2.Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL). 3.Approved by Factory Mutual Research Corporation(FM). 4.Approved by the City of New York under MEA 354-01-E. 5.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. " 150°F/66°C Maximum Ceiling Temperature. With Zinc Plated Shield. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS Page 4 of 6 TFP351 Physical Characteristics —Upright Sprinklers— Frame . . . . . . . . . . . . . Bronze The Series TY-B Intermediate Level Button . . . . . . . . . Brass/Copper Upright Sprinklers must be installed in Sealing Assembly . . . . . . . . accordance with the following instruc- / WRENCH RECESS Beryllium Nickel w/Teflont tions. (END"A"USED FOR Bulb . . . . . . . . . . . . . . . Glass Step 1. With pipe thread sealant ap- plied 1/2"NPT MODELS) Compression Screw Bronze plied to the pipe threads, hand tighten Deflector . . . . . . . . . . . Copper the sprinkler into the sprinkler fitting. Shield . . . . . . . . . . Plated Steel Step 2. Tighten the sprinkler into the WRENCH RECESS sprinkler fitting using only the W-Type (END"B"USED FOR 6 Sprinkler Wrench (Ref. Figure 3), 3/4"NPT MODELS) Operation except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax FIGURE 3 The glass Bulb contains a fluid which coated sprinklers. With reference to W-TYPE 6 SPRINKLER expands when exposed to heat.When Figure 1 or 2, the W-Type 6 Sprinkler WRENCH the rated temperature is reached, the Wrench or the Crescent wrench, as fluid expands sufficiently to shatter the applicable, is to be applied to the glass Bulb, allowing the sprinkler to wrench flats. activate and water to flow. ing the wrench. — Pendent Sprinklers—The Series TY-B Intermediate Level After installation, the sprinkler wrench flats and frame arms must be in- Design Pendent Sprinklers must be installed spected and the wax coating re- in accordance with the following in touched(repaired)whenever the coat- Criteria structions. ing has been damaged and bare metal Step 1.Thread the S2 Shield onto the is exposed. The wax coating on the The Series TY-B Pendent and Upright sprinkler threads with the stamped wrench flats can be retouched by gen- Intermediate Level Sprinklers are in- markings toward the deflector and just tly applying a heated 1/8 inch diameter tended for fire protection systems de- to the end of the threads. The final steel rod to the areas of wax that have signed in accordance with the stand- assembly step is easier to accomplish been damaged,to smooth it back over and installation rules recognized by the if the Shield is not disengaged by con- areas where bare metal is exposed. applicable Listing or Approval agency tinuing to turn the Shield past the (e.g., UL Listing is based on the re- threads. NOTES quirements of NFPA 13, and FM Ap Step 2. Roll the O-Ring over the sprin Only retouching of the wax coating ap- proval is based on the requirements of er threads until it seats against the plied to the wrench flats and frame FM's Loss Prevention Data Sheets). Shield. arms is permitted, and the retouching is to be performed only at the time of Step 3. With pipe thread sealant ap- the initial sprinkler installation. Installation plied to the pipe threads, hand tighten The steel rod should be heated only to the sprinkler into the sprinkler fitting. the point at which it can begin to melt The Series TY-B Sprinklers must be Step 4. Tighten the sprinkler into the the wax, and appropriate precautions installed in accordance with the follow- sprinkler fitting using only the W-Type need to be taken, when handling the ing instructions: 6 Sprinkler Wrench (Ref. Figure 3). heated rod, in order to prevent the With reference to Figure 1 or 2, the installer from being burned. NOTES W-Type 6 Sprinkler Wrench is to be If attempts to retouch the wax coating Do not install any bulb type sprinkler if applied to the wrench flats. with complete coverage are unsuc- the bulb is cracked or there is a loss of Step 5.Rotate the S2 Shield clockwise cessful,additional wax can be ordered liquid from the bulb. With the sprinkler (looking up) so that it slightly com- in the form of a wax stick (the end of held horizontally, a small air bubble presses the O-Ring between the which is color coded).Only the correct should be present. The diameter of the Shield and sprinkler fitting. color coded wax is to be used, and air bubble is approximately 1116 inch retouching of wrench flats and frame (1,6 mm) for the 135°F/57°C to 3132 arms is only permitted at the time of inch (2,4 mm) for the 360°F/182°C —Wax Coated Sprinklers— initial sprinkler installation. With the temperature ratings. When installing wax coated sprinklers steel rod heated as previously de- A leak tight 112 inch NPT sprinkler joint with the adjustable Crescent wrench, scribed, touch the rod to the area re- should be obtained with a torque of 7 additional care needs to be exercised quiring additional wax with the rod an- to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- to prevent damage to the wax coating gled downward, and then touch the mum of 21 ft. lbs. (28,5 Nm)of torque on the sprinkler wrench flats or frame wax stick to the rod approximately one- may be used to install sprinklers with arms and, consequently, exposure of half inch away from the area requiring 112 NPT connections. A leak tight 314 bare metal to the corrosive environ- retouching. The wax will melt and run inch NPT sprinkler joint should be ob- ment. The jaws of the wrench should down onto the sprinkler. tained with a torque of 10 to 20 ft.lbs. be opened sufficiently wide to pass (13,4 to 26,8 Nm). A maximum of 30 over the wrench flats without damag- ft.lbs. (40,7 Nm)of torque is to be used ing the wax coating. Before wrench to install sprinklers with 314 NPT con- tightening the sprinkler,the jaws of the nections. Higher levels of torque may wrench are to be adjusted to just con- distort the sprinkler inlet and cause tact the sprinkler wrenching flanges. leakage or impairment of the sprinkler. After wrench tightening the sprinkler, loosen the wrench jaws before remov- TFP351 Page 5 of 6 Care and It r recommended that automatic Ordering sprinkler systems be inspected, tested, and maintained by a qualified procedure Maintenance Inspection Service in accordance with local requirements and/or national The Series TY-B Sprinklers must be code. When placing an order,indicate the full maintained and serviced in accord- product name. Refer to the Price List ance with the following instructions: for complete listing of Part Numbers. Limited y NOTES Contact your local distributor for avail- Before closing a fire protection system Warrant ability. main control valve for maintenance Upright Sprinkler Assemblies with work on the fire protection system that Products manufactured by Tyco Fire Shield and NPT Thread itcontrols,permission to shutdown the Products are warranted solely to the affected fire protection system must be original Buyer for ten (10) years Connections: obtained from the proper authorities against defects in material and work- Specify: (Specify Model/SIN), Stand- and all personnel who maybe affected manship when paid for and properly and Response, (specify K-factor), by this action must be notified. installed and maintained under normal (specify temperature rating), Series use and service.This warranty will ex- TY-B Upright Intermediate Level Sprin- Sprinklers that are found to be leaking pire ten (10) years from date of ship- kler with (specify type of finish or coat- or exhibiting visible signs of corrosion ment by Tyco Fire Products. No war- ing), P/N (specify from Table B). must be replaced. ranty is given for products or Automatic sprinklers must never be components manufactured by compa- Pendent Sprinkler Assemblies with (Shield Ordered Separately)and painted, plated, coated or otherwise nies not affiliated by ownership with altered after leaving the factory. Modi- Tyco Fire Products or for products and NPT Thread Connections: Specify: (Specify Model/SIN), Stand fied sprinklers must be replaced. components which have been subject Sprinklers that have been exposed to to misuse, improper installation,corro- and Response, (specify K factor), corrosive products of combustion, but sion, or which have not been installed, (specify temperature rating), Series have not operated,should be replaced maintained,modified or repaired in ac- TY-B Pendent Sprinkler with (specify if they cannot be completely cleaned cordance with applicable Standards of type of finish or coating), P/N (specify by wiping the sprinkler with a cloth or the National Fire Protection Associa- from Table C) by brushing it with a soft bristle brush. tion, and/or the standards of any other Model S2 Pendent Shield &O-Ring: Care must be exercised to avoid dam- Authorities Having Jurisdiction. Mate- Specify: S2 Pendent Shield & O-Ring age to the sprinklers - before, during, rials found by Tyco Fire Products to be for use with (specify 1/2" NPT or 3/4" and after installation. Sprinklers dam- defective shall be either repaired orreplaced, at Tyco Fire Products' sole NPT) Series TY-B Pendent Sprinklers, aged by dropping, striking, wrench option. Tyco Fire Products neither as P/N (specify). twist/slippage, or the like, must be re- sumes, nor authorizes any person to placed.Also, replace any sprinkler that assume for it, an other obligation ation in 1/2" NPT S2 has a cracked bulb or that has lost y g Pendent Shield liquid from its bulb. (Ref. Installation connection with the sale of products or &O-Ring .............. P/N 56-070-9-332 Section). parts of products. Tyco Fire Products 3/4 NPT S?Shield shall not be responsible for sprinkler Frequent visual inspections are rec- system design errors or inaccurate or &O-Ring .............. P/N 56-070-9-342 ommended to be initially performed for incomplete information supplied by Sprinkler Wrench: corrosion resistant coated sprinklers, Buyer or Buyer's representatives. Specify: W-Type 6 Sprinkler Wrench, after the installation has been com- IN NO EVENT SHALL TYCO FIRE P/N 56-000-6-387. pleted,to verify the integrity of the cor- PRODUCTS BE LIABLE, IN CON- rosion resistant coating. Thereafter, TRACT,TORT,STRICT LIABILITY OR Wax Sticks: annual inspections per NFPA 25 UNDER ANY OTHER LEGAL THE- (for retouching wrench damaged should suffice; however, instead of in- ORY, FOR INCIDENTAL, INDIRECT, wax coating) specting from the floor level,a random SPECIAL OR CONSEQUENTIAL Specify: (Specify color) color coded sampling of close-up visual inspec- DAMAGES, INCLUDING BUT NOT Wax Stick for retouching (specify tem- tions should be made, so as to better LIMITED TO LABOR CHARGES, RE- perature rating)temperature rated Se- determine the exact sprinkler condi- GARDLESS OF WHETHER TYCO ries TY-B Sprinklers, P/N (specify). tion and the long term integrity of the FIRE PRODUCTS WAS INFORMED corrosion resistant coating, as it may ABOUT THE POSSIBILITY OF SUCH Black for 135°F............ P/N 56-065-1-135 be affected by the corrosive conditions DAMAGES, AND IN NO EVENT Red for 1 ............. P/N 56-065-1-155 present. Yellow forr 17575°F. . . . .. . . . P/N 56-065-1-175 SHALL TYCO FIRE PRODUCTS' Lk Blue for 200°F and The owner is responsible for the in- ABILITY EXCEED AN AMOUNT 286°F................. P/N56-065-1-286 EQUAL TO THE SALES PRICE spection, testing, and maintenance of . their fire protection system and de- THE FOREGOING WARRANTY IS NOTES Each wax stick is suitable for retouch- vices in compliance with this docu- MADE IN LIEU OF ANY AND ALL ment, as well as with the applicable OTHER WARRANTIES EXPRESS OR ing up to twenty-five sprinklers. standards of the National Fire Protec- IMPLIED,INCLUDING WARRANTIES The wax used for 286°F sprinklers is tion Association (e.g., NFPA 25), in OF MERCHANTABILITY AND FIT- the same as for 200°Fsprinklers, and, addition to the standards of any other NESS FOR A PARTICULAR PUR- therefore,the 286°Fsprinkler is limited authorities having jurisdiction. The in- POSE. to the same maximum ceiling tempera- stalling contractor or sprinkler manu- ture as the 200oF sprinkler (i.e., facturer should be contacted relative to 150°F). any questions. Page 6 of 6 TFP351 P/N 57 - XXX - X - XXX TEMPERATURE TI SPRINKLER RANG MODEUSIN 135 135°F/57°C 533 5.6K UPRIGHT(1/2"NPT) TY3153 1 NATURAL BRASS 155 155°F/68°C 543 8.OK UPRIGHT(3/4"NPT) TY4153 7 LEAD COATED 175 175°F/79°C 6 WAX COATED 200 200°F/93°C 286°F/141°C MAX. 286 286°F/141°C 8 WAX OVER LEAD 286°F/141°C MAX. 360 360°F/182"C TABLE B PART NUMBER SELECTION SERIES TY-B UPRIGHT INTERMEDIATE LEVEL SPRINKLERS (UPRIGHT SHIELD INCLUDED WITH SPRINKLER) P/N 57 - XXX - X - XXX TEMPERATURE TI SPRINKLER RANG MODEUSIN 135 135°F/57°C 571 5.6K PENDENT(1/2"NPT) TY3251 1 NATURAL BRASS 155 155°F/68°C 591 8.OK PENDENT(3/4"NPT) TY4251 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C 360 360°F/182°C TABLE C PART NUMBER SELECTION SERIES TY-B PENDENT SPRINKLERS (MODEL S2 PENDENT SHIELD& O-RING MUST BE SEPARATELY ORDERED) TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale, Pennsylvania 19446 tqCaRre Suppression & Building Products Technical Services 800-381-9312 1+1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Corrosion-resistant coatings, where applicable, are utilized to extend the Description life of copper alloy sprinklers beyond that which would otherwise be obtained i d corrosive atmo- hen expose to corros The TYCO Series TY-FRB,2.8,4.2,5.6, w and 8.0 K-factor, Upright and Pendent spheres.Although corrosion-resistant Sprinklers described in this data sheet coated sprinklers have passed the j are quick response,standard coverage, standard corrosion tests of the appli- N decorative 3 mm glass bulb-type spray cable approval agencies,the testing is sprinklers designed for use in light or not representative of all possible cor- ordinary hazard,commercial occupan- rosive atmospheres. Consequently, cies such as banks, hotels, and shop- it is recommended that the end user ping malls. be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment. The effects of FRB Pendent Sprinkler,where applica- ambient temperature, concentration of ble, is intended for use in areas with a chemicals, and gas/chemical velocity, finished ceiling.This recessed pendent should be considered, as a minimum, sprinkler uses one of the following, along with the corrosive nature of the • A two-piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be i or Style 40 (3/4 inch NPT) Recessed exposed. Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- a l recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed —_ (19,1 mm)of total adjustment from the in Technical Data Sheet TFP356, and flush ,or a pendent position,P P Sprinkler Guards are detailed in Tech- • A two-piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch(6,4 mm)of recessed adjustment or up to 1/2 inch The Series TY-FRB Concealed Pendent Model/Sprinkler (12,7 mm)of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- Number (SIN) Recessed Escutcheon reduces the cable standards of the National Fire accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2-NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2-NPT the performance of these devices. TY2131: Upright 4.2K, 1/2-NPT Owners are responsible for maintaining TY2231: Pendent 4.2K, 1/2-NPT their fire protection system and devices TY3131: Upright 5.6K, 1/2-NPT in proper operating condition. The TY3231: Pendent 5.6K, 1/2-NPT IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.OK, 3/4-NPT Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.OK, 3/4-NPT Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.OK, 1/2-NPT WARNING" that provides cautions TY4931: Pendent* 8.OK, 1/2-NPT with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* \ 5 7/16° 2-1/4" q (11,1 mm) NOMINAL (57,2 mm) 2 MAKE-IN 3 2-3/16" 1-9/16" (55,6 mm) WRENCH (39,7 mm) 1 FLATS 7 1/2" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5W2-3/16" 7/16" (11,1 mm) 2-3/16" 4NOMINAL (55,6 mm) MAKE-IN 2 ,6 mm) WRENCH (38,1 mm) 3 FLATS 1 1/2" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP171 Page 3 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5T2-3/16" 7/16" (11,1 mm) 2-3/16" 4NOMINAL (55,6 mm) MAKE-IN 2 1-1/2" ,6 mm) WRENCH (38,1 mm) 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT 112"(12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU* NOMINAL 3/4„ PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON i 6*, 5_ 1/2" (12,7 mm) 2-5/16" 4 NOMINAL (58,7 mm) MAKE-IN (57,2 mm) (39,7 mm) 3 1 �3/4" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFP171 Page 4 of 10 7/16"(11,1 mm) SSU* NOMINAL 1/2" DEFLECTOR MAKE-IN NPT 6* 1, T I _T 57/ (55,6mm) 7/16" (11,1 mm) f 2-1/4" 4NOMINAL (57,2 mm) MAKE-IN 22-3/16" 1-9/16" WRENCH (39,7 mm) 3 FLATS 1 f SSP* Il CROSS 112" NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Technical O eration inch (1,6 mm) for the 135°F/57°C and N 3132 inch(2,4 mm)for the 286°F/141°C Data The glass Bulb contains a fluid that temperature ratings. expands when exposed to heat.When Obtain a leak-tight 112 inch NPT sprin- Approvals the rated temperature is reached, the kler joint by applying a minimum to UL and C-UL Listed fluid expands sufficiently to shatter the maximum torque of 7 to 14 ft.lbs. (9,5 FM, LPCB, and NYC Approved glass Bulb, allowing the sprinkler to to 19,0 Nm). Higher levels of torque Refer to Table A and B for complete activate and water to flow. can distort the sprinkler Inlet with con- approval information including sequent leakage or impairment of the corrosion-resistant status. Design sprinkler. Maximum Working Pressure Criteria not attempt to compensate for Refer to Table C. insufficient adjustment in the Escutch- eon Plate by under-or over-tightening Discharge Coefficient The TYCO Series TY-FRB Pendent the sprinkler. Re-adjust the position of K=2.8 GPM/psi1i2 (40,3 LPM/bar1/2) and Upright Sprinklers are intended the sprinkler fitting to suit. K=4.2 GPM/psi1i2 (60,5 LPM/bar1/2) for fire protection systems designed in The Series TY-FRB Pendent and accordance with the standard installa- K=5.6 GPM/psi1i2 (80,6 LPM/bar1/2) tion rules recognized by the applicable Upright Sprinklers must be installed K=8.0 GPM/psi1i2 (115,2 LPM/bar1/2) Listing or Approval agency(such as, UL in accordance with the following Temperature Rating Listing is based on the requirements of instructions. Refer to Table A and B. NFPA 13,and FM Approval is based on 1. Install Pendent sprinklers in the the requirements of FM's Loss Preven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10, sprinklers in the upright position. Sprinkler: Refer to Table A and B. 20,30,or 40 Recessed Escutcheon,as Recessed Escutcheon: White Coated, applicable, is to be used for recessed 2 With pipe-thread sealant applied to Chrome Plated, or Brass Plated. pendent installations. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Physical Characteristics Installation 3. Tighten the sprinkler into the sprin- Frame. . . . . . . . . . . . . . . . . . . Bronze kler fitting using only the W-Type 6 Button. . . . . . . . . . . . . .Brass/Copper The TYCO Series TY-FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly. . . . . . . . .Beryllium must be installed in accordance with reference to Figures 1 through Nickel w/Teflont the following instructions. 5, apply the W-Type 6 Sprinkler Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Wrench to the sprinkler wrench Compression Screw. . . . . . . . Bronze flats. Deflector. . . . . . . . . . .Copper/Bronze LEM Bushing (K=2.8) . . . . . . . . . . . Bronze Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter t Registered Trademark of Dupont of the air bubble is approximately 1116 TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K BULB LIQUID NATURAL CHROME WHITE*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) and 175°F/79°C Yellow 1,2,3,4 UPRIGHT(TY1131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 2,8 RECESSED 1/2"NPT PENDENT 155°F/68°C Red (TY1231)* 175°F/79°C Yellow Figure 6 200°F/93°C Green 135°F/57°C Orange 1 2 4 RECESSED PENDENT 155°F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79°C Yellow UPRIGHT(TY2131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F/68°C Red 1,2 (TY2231)" 175°F/79°C Yellow Figure 8 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** 175°F/79°C Yellow Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT(TY3231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F/93°C Green (TY3131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 5.6 PENDENT 175°F/79°C Yellow 1,2,4,5 N/A 1/2"NPT (TY3231)* Figure 10 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,4,5 N/A (TY3231)** Figure 11 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT(TY4231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F/93°C Green (TY4131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 8.0 PENDENT 175°F/79°C Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 12 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,5 N/A (TY4231)** Figure 13 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 8.0 PENDENT 155°F/68°C Red 1/2$NPT (TY4931)and 175°F/79°C Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F/93°C Green (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. "Installed with Style 10(112"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. Frame and Deflector only. Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and (12,1 BAR) 5.6 UPRIGHT(TY3131) OR 105 PSI (11(12,BAR) 1/2"NPT (SEE NOTE 1) 1 BAR) RECESSED N/A PENDENT(TY3231) PENDENT(TY4231) 175 PSI and UPRIGHT(TY4131) (12,1 BAR) 8.0 175 PSI(12,1 BAR) 3/4"NPT RECESSED N/A PENDENT(TY4231) 8.0 PENDENT(TY4931) 175 PSI 1/2"NPT and 175 PSI(12,1 BAR) (12,1 BAR) UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent Care and Exercise care to avoid damage to Sprinklers must be installed in accor- sprinklers before, during, and after dance with the following instructions. installation. Never paint, plate, coat, 1. After installing the Style 10, 20, 30, Maintenance or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY-FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe-thread sealant applied to with the following instructions. . were modified or over-heated. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. • were damaged by dropping,striking, wrench twisting,wrench slippage,or 2. Tighten the sprinkler into the sprin- Before closing a fire protection system the like. kler fitting using only the W-Type 7 main control valve for maintenance . are leakingor exhibiting visible signs Recessed Sprinkler Wrench (Fig- work on the fire protection system g g ure 15). With reference to Figures 1 of corrosion. � g that it controls, obtain permission to to 4, apply the W-Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by-products with a cloth. ing, slide on the Style 10, 20, 30, or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY-FRB escutcheon, which is used to cover uid from the bulb. Refer to the Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. TFP171 Page 8 of 10 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" ' (3,2 mm) (3,2 mm) l MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. _ 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8 (73,0 mm) y 1/2"(12,7 mm) " (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) I 1 MOUNTING MOUNTING SURFACE SURFACE/ + CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 112 INCH NPT Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam- random samples are recommended for the inspection, testing, and mainte- age to the sprinklers -before, during, corrosion-resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam- the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has a cracked bulb or that has lost Inspections of corrosion-resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- Section). or range, instead of from the floor level sprinkler Contact the installing contractornkler manufacturer regarding any y Initial and frequent visual inspections of per NFPA. Inspection at close range spri random samples are recommended for can better determine the exact sprin- questions. corrosion-resistant sprinklers to verify kler condition and the long-term integ- Automatic sprinkler systems are rec- the integrity of the corrosion-resistant rity of the corrosion-resistant material, ommended to be inspected, tested, material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and/or national codes. TFP171 Page 9 of 10 2-7/8" DIA. _ 2-7/8" DIA. _ 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / (3,2 mm) (3,2 mm) 1 MOUNTING MOUNTING SURFACE SURFACE /I,/ CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. _ 2-7/8" DIA. 5/8 1/4" (73,0 mm) 3/4"(19,1 mm) 1/2 1/8" (73,0 mm) 1/2"(12,7 mm) (15,9 6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7 3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) I 1 MOUNTING MOUNTING71 I SURFACE SURFACE 4 11 CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT &0 K-FACTOR, 314 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range / WRENCH RECESS can better determine the exact sprin- (END"A" USED FOR kler condition and the long-term integ- 1/2" NPT MODELS) rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END"B" USED FOR 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH FIGURE 14 SPRINKLER WRENCHING AREA W-TYPE 6 SPRINKLER FIGURE 15 WRENCH W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX MODEL/SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 4 WHITE POLYESTER 155 155°F(68°C) 340 4.2K UPRIGHT(1/2"NPT) TY2131 3 WHITE(RAL9010)" 175 175°F(79°C) 341 4.2K PENDENT(1/2"NPT) TY2231 9 CHROME PLATED 200 200°F(93°C) 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.61K PENDENT(1/2"NPT) TY3231 390 8.OK UPRIGHT(3/4"NPT) TY4131 391 8.OK PENDENT(3/4"NPT) TY4231 360 8.OK UPRIGHT(1/2"NPT) TY4831' Eastern Hemisphere sales only. 361 8.OK PENDENT(1/2"NPT) TY4931` TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS responsible for sprinkler system design Limited ordering errors or inaccurate or incomplete infor- Warrant r supplied by Buyer or Buyer's procedure Y representatives. Products manufactured by Tyco Fire In no event shall TFSBP be liable, in Contact your local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to the any other legal theory, for incidental, indicate the full product name and Part original Buyer for ten(10)years against indirect,special or consequential dam- Number(P/N). defects in material and workmanship ages, including but not limited to labor when paid for and properly installed charges, regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of Thread Connections service. This warranty will expire ten such damages, and in no event shall Specify: (Specify Model/SIN), Quick (10) years from date of shipment by TFSBP's liability exceed an amount Response, (specify K-factor), (specify TFSBP. No warranty is given for prod- equal to the sales price. temperature rating), Series TY-FRB ucts or components manufactured by s ecif Pendent or Upright) Sprinkler companies not affiliated by ownership The foregoing warranty is made in lieu (specify with TFSBP or for products and com- of any and all other warranties,express with (specify type of finish or coating), ponents which have been subject to or implied, including warranties of mer- P/N (specify from Table D). misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: sion, or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify") accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify'). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and/or the standards of any other als or components,whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract,tort, strict liability or Specify: W-Type 6 Sprinkler Wrench, rials found by TFSBP to be defective any other legal theory. P/N 56-000-6-387. shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W-Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law.The invalidity, P/N 56-850-4-001. to assume for it, any other obligation in in whole or part, of any portion of this Refer to Technical Data Sheet TFP770. connection with the sale of products or warranty will not affect the remainder. parts of products.TFSBP shall not be Copyright©2007-2010 Tyco Fire Suppression&Building Products.All rights reserved. CO® Worldwide www.tyco-fire.com Contacts Series TY.B - 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the Description standard corrosion tests of the appli- The TYCO Series TY-B, 5.6 K-factor, cable approval agencies,the testing is Horizontal and Vertical Sidewall Sprin- not representative of all possible cor- klers described in this technical data rosive atmospheres. Consequently, sheet are standard response,standard it is recommended that the end user coverage decorative 5 mm glass bulb be consulted with respect to the suit- ttype spray sprinklers designed for use ability of these coatings for any given light and ordinary hazard, c for er-use corrosive environment. The effects of in light occupancies such as banks,hotels, ambient temperature,concentration of and shopping malls. chemicals, and gas/chemical velocity, should be considered, as a minimum, They are designed for installation along along with the corrosive nature of the a wall or the side of a beam and just chemical to which the sprinklers will be beneath a smooth ceiling. Sidewall exposed. sprinklers are commonly used instead of pendent or upright sprinklers due LEM to aesthetics or building construction The Series TY-B Sprinklers described considerations, where piping across herein must be installed and main- the ceiling is not desirable. tained in compliance with this docu- The recessed version of the Series ment, as well as with the applicable TY-B Horizontal Sidewall Sprinkler is standards of the National Fire Protec- intended for use in areas with a fin- tion Association,in addition to the stan- ished wall. It uses a two-piece Style 10 dards of any other authorities having Recessed Escutcheon. The Recessed jurisdiction.Failure to do so may impair Escutcheon provides 1/2 in. (12,7 mm) the performance of these devices. of recessed adjustment or up to 3/4 in. The owner is responsible for main- (19,1 mm) of total adjustment from the taining their fire protection system flush sidewall position.The adjustment and devices in proper operating con- provided by the Recessed Escutcheon dition. Contact the installing contrac- Maximum Working Pressure reduces the accuracy to which the fixed for or product manufacturer with any Refer to Table B pipe nipples to the sprinklers must be questions. Discharge Coefficient cut. K=5.6 gpm/psis/2(80,6 Ipm/bars/2) Corrosion-resistant coatings, where Sprinkler Temperature Ratings applicable,are utilized to extend the life of copper alloy sprinklers beyond that Identification Refer to Table A which would otherwise be obtained Finishes Nu M be rs Sprinkler: Refer to Table C TY3351. . . . . . . . Horizontal Sidewall Recessed Escutcheon:Signal or Pure IMPORTANT White,Grey Aluminum,Jet Black,Chrome Refer to Technical Data Sheet TY3451. . . . . . . . . . .Vertical Sidewall Plated,or Natural Brass TFP2300 for warnings pertaining to Physical Characteristics regulatory and health information. Technical Frame ............................Bronze Always refer to Technical Data Button......................Brass/Copper Sheet TFP700 for the "INSTALLER Data Sealing Assembly. Beryllium Nickel w/TEFLON WARNING" that provides cautions Bulb pressi .........................Glass p Approvals Compression Screw.......... ...Bronze with respect to handling and instal- UL and als Listed HSW Deflector .....................Bronze lation of sprinkler systems and com- UL Approved VSW Deflector..................... Copper ponents. Improper handling and FIVI LPCB Certified installation can permanently damage NYC Approved a sprinkler system or its compo- nents and cause the sprinkler to fail (Refer to Table A for complete approval to operate in a fire situation or cause information, including corrosion-resis- it to operate prematurely. tant status.) Page 1 of 6 JULY 2018 TFP161 TFP161 Page 2of6 DEFLECTOR \ DEFLECTOR 1 - Frame HAT �, \ 5 1 - Frame HAT 5 2 - Button � \ 2 - Button � 3 - Sealing 3 - Sealing Assembly Assembly 4 - Bulb 4 - Bulb 5 - Compression 5 - Compression Screw Screw 6 - Deflector* 6* 4 2 3 1 6 - Deflector* 6* 4 2 3 1 9/16" WRENCH 1/2"** 9/16" WRENCH 1/2" (14,3 mm) FLATS NPT (14,3 mm) FLATS NPT O _ O 1-13/16" 7/16" 1-13/16" 7/16" (46,0 mm) (11,1 mm) (46,0 mm) (11,1 mm) CENTERLINE NOMINAL CENTERLINE NOMINAL OF SPRINKLER MAKE-IN OF SPRINKLER MAKE-IN WATERWAY 1 1/2" WATERWAY 1-1/2" (38,1 mm) _ (38,1 mm) ESCUTCHEON ESCUTCHEON PLATE SEATING 2-3/16" _ PLATE SEATING 2-3/16" SURFACE (55,6 mm) SURFACE (55,6 mm) STYLE 10 STYLE 10 RECESSED RECESSED 1 ESCUTCHEON ESCUTCHEON *Temperature rating is *Temperature rating is indicated on Deflector indicated on Deflector jii ** Pipe thread connections per ISO 7-1 can be provided on special request 2-7/8" DIA. 2-7/8" DIA. (73,01 mm) (73,01 mm) 1 1 ALL FINISHES EXCEPT POLY-STAINLESS POLY-STAINLESS FINISH ONLY FIGURE 1 SERIES TY-B TY3351 HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR STANDARD RESPONSE Poly-Stainless Physical Characteristics Design Criteria Installation Frame ............................Bronze Button................ L316316 Stainless Steel` The TYCO Series TY-B, 5.6 K-fac- The TYCO Series TY-B, 5.6 K-factor, St Bulb...............................Glass tor, Horizontal and Vertical Side- Horizontal and Vertical Sidewall Sprin- Compression Screw..... L316 Stainless Steel` wall Sprinklers are intended for klers must be installed in accordance HSW Deflector ..............Copper/Bronze fire protection systems designed with this section. Sealing Assembly.Gold Plated Beryllium Nickel In accordance with the standard w/TEFLON installation YUIeS recognized by General Instructions *Type L316 stainless steel(UNS 31603)per ASTM YeCO n g A479/479M or BS EN 1008 WN1.4404. the applicable Listing or Approval Do not install any bulb type sprinkler agency (for example, UL Listing is if the bulb is cracked or there is a loss Operation based on the requirements of NFPA of liquid from the bulb. With the sprin- The glass bulb contains a fluid which 13, and FM Approval is based on the kler held horizontally,a small air bubble expands when exposed to heat.When requirements of the FM Loss Preven- should be present.The diameter of the the rated temperature is reached, the tion Data Sheets). Only the Style 10 air bubble is approximately 1/16 in. fluid expands sufficiently t0 Shatter the Recessed Escutcheon, as applicable, (1,6 mm)for the 135oF(57°C)to 3/32 in. glass bulb, allowing the sprinkler to is to be used for recessed horizontal (2,4 mm)for the 360 F(182 C)tempera- activate and water to flow. installations. ture ratings. TFP161 Page 3of6 *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection rating is connections 2 - Button 5 - Compression Spring indicated on per ISO 7-1 can 3 - Sealing Screw Deflector. be provided on Assembly 6 - Deflector* WRENCH RECESS special request. (END"A" USED FOR ARROW MUST 1/2" NPT MODELS) POINT AWAY 7/16" FROM AND BE FIGURE 4 ESCUTCHEON (11,1 mm) PERPENDICULAR O W-TYPE6 PLATE SEATING ** NOMINAL TO THE BACK /� SPRINKLER WRENCH SURFACE NPT MAKE-IN WALL SURFACE WRENCH 6* RECESS FLOW 52-3 (55,6/m", 2-3/16" 4 1 J 55,6 mm) 1-1/2" \ 2 (38,1 mm) WRENC FLATS 3 i PUSH WRENCH 1 IN TO ENSURE SHOWN SHOWN CROSS ENGAGEMENT PENDENT UPRIGHT SECTION WITH SPRINKLER FIGURE 2 WRENCHING AREA SERIES TY-B VERTICAL SIDEWALL(TY3451)SPRINKLER FIGURE 5 5.6 K-FACTOR, STANDARD RESPONSE W-TYPE 7 RECESSED SPRINKLER WRENCH 5/8 1/4" Horizontal Sidewall Sprinkler (15,9 6,4 mm) Installation FACE OF The TYCO Series TY-B Recessed Hor- MOUNTING izontal Sidewall Sprinklers must be SURFACE SPRINKLER installed in accordance with the fol- lowing instructions. Install recessed horizontal sidewall sprinklers in the horizontal position with the centerline CLOSURE of waterway perpendicular to the back wall and parallel to the ceiling. The 2-7/8" DIA. word "TOP" on the Deflector is to face SERIES (73,0 mm) towards the ceiling. - TY-B - 2-1/4" DIA. Step A. After installing the Style 10 (57,2 mm) Mounting Plate over the sprinkler threads,hand-tighten the sprinkler into MOUNTING - 11 the sprinkler fitting. PLATE Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 5). Apply the W-Type 7 Recessed Sprinkler Wrench to the (3,2 mm) sprinkler wrench flats(Ref. Figure 1). 1-1/4" (31,8 mm) 3/4"(19,1 mm) Step C.After the ceiling is installed or 3/4" (19,1 mm) 1/4"(6,4 mm) the finish coat is applied, slide on the Style 10 Closure over the Series TY-B FIGURE 3 Sprinkler and push the Closure over the SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Mounting Plate until its flange comes in WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT contact with the ceiling. STYLE 10 RECESSED ESCUTCHEON, 5.6 K-FACTOR, 112 INCH NPT A leak-tight 1/2 in. NPT sprinkler make-up for insufficient adjustment in joint should be obtained by apply- the escutcheon plate by under-or over- ing a minimum-to-maximum torque of tightening the sprinkler. Readjust the 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher position of the sprinkler fitting to suit. levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to TFP161 Page 4of6 Vertical Sidewall Sprinkler INOTim Automatic sprinklers must never be Installation painted, plated, coated, or other- The Series TY-B Vertical Sidewall Only retouching of the wax coating wise altered after leaving the factory. Sprinklers must be installed in accor- applied to the wrench flats and frame Modified sprinklers must be replaced. dance with the following instructions. arms is permitted, and the retouching Sprinklers that have been exposed to Install vertical sidewall sprinklers in the t i be performed only at the time of corrosive products of combustion, but pendent or upright position with the the initial sprinkler installation. have not operated,should be replaced arrow on the Deflector pointing away The steel rod should be heated only if they cannot be completely cleaned from the wall. to the point at which it can begin to by wiping the sprinkler with a cloth or Step 1. With pipe thread sealant melt the wax, and appropriate precau- by brushing it with a soft bristle brush. applied to the pipe threads, hand- tions need to be taken when handling Care must be exercised to avoid tighten the sprinkler into the sprinkler the heated rod in order to prevent the damage to the sprinklers before, fitting. installer from being burned. during, and after installation. Sprin- Step 2. Tighten the sprinkler into the Care and klers damaged by dropping, striking, sprinkler fitting using only the W-Type wrench twist/slippage,or the like, must 6 Sprinkler Wrench (Ref. Figure 4). For be replaced.Also,replace any sprinkler wax-coated sprinklers, use an 8 or 10 Maintenance that has a cracked bulb or that has lost in. adjustable Crescent wrench. Apply The TYCO Series TY-B, 5.6 K-factor, liquid from its bulb. (Refer to Installa- tionthe W-Type 6 Sprinkler Wrench or the Horizontal and Vertical Sidewall Sprin- Section.) Crescent wrench,as applicable,to the klers must be maintained and serviced The owner is responsible for the wrench flats(Ref. Figure 2). in accordance with this section. inspection,testing,and maintenance of When installing wax-coated sprinklers Before closing a fire protection system their fire protection system and devices with the adjustable Crescent wrench, main control valve for maintenance in compliance with this document, as well as with the applicable standards exercise care to prevent damage to the work on the fire protection system wax coating on the sprinkler wrench that it controls, obtain permission to of the National Fire Protection ion to flats or frame arms and, consequently, shut down the affected fire protection the s n standards N f a y of in addition to exposure of bare metal to the corro- system from the proper authorities the standards of any other authorities sive environment.Open the jaws of the and notify all personnel who may be having jurisdiction.Contact the install wrench sufficiently wide to pass over affected by this action. ing contractor or product manufacturer with any questions. the wrench flats without damaging the wax coating. Before wrench-tighten- The owner must assure that the sprin- Automatic sprinklers are recommended ing the sprinkler, adjust the jaws of the klers are not used for hanging any to be inspected,tested,and maintained wrench to contact only the sprinkler objects and that the sprinklers are only by a qualified Inspection Service in wrench flats. After wrench tightening cleaned by means of gently dusting accordance with local requirements the sprinkler, loosen the wrench jaws with a feather duster; otherwise, non- and/or national codes. before removing the wrench. operation in the event of a fire or inad- After installation, inspect the sprin- vertent operation may result. kler wrench flats and frame arms and Absence of an escutcheon, which is retouch(repair)the wax coating when- used to cover a clearance, may delay ever the coating has been damaged the time to sprinkler operation in a fire and bare metal is exposed. Retouch situation. the wax coating on the wrench flats by Sprinklers which are found to be gently applying a heated 1/8 in. diam- leaking or exhibiting visible signs of eter steel rod to the damaged areas of corrosion must be replaced. wax to smooth it back over areas where bare metal is exposed. TFP161 Page 5of6 SPRINKLER FINISH(10) K SPRINKLER TEMPERATURE QUIP WAX- TYPE RATING COLOR NATURAL CHROME POLYESTERS POLY- LEAD WAX OVER- BRASS PLATED STAINLESS° COATED COATED LEAD COATED 135°F(57°C) Orange 155°F(68°C) Red HORIZONTAL 175°F79°C Yellow 1,2,3,4,9 1,2,3,9 1,2,3,9 SIDEWALL ( ) 1,2 1,2,3,9 (TY3351) 200°F(93°C) Green Figure 1 5.6 286°F(141°C) Blue 11h,2b,3b,9b 1/2 in. NPT 360°F(182°C) Mauve 1,2,4,9 1,2,9 N/A RECESSED 135°F(57°C) Orange HORIZONTAL 155°F(68°C) Red SIDEWALL 1,2,3,9 1,2 N/A (TY3351)a 175°F(79°C) Yellow Figure 3 200°F(93°C) Green 135°F(57°C) Orange VERTICAL 155°F(68°C) Red SIDEWALL 5,6,7,9 5.6 (TY3451) 175°F(79°C) Yellow 4,5,6,7,8,9 N/A 1/2 in. PENDENT 5,6,7,9 NPT or 200°F(93°C) Green UPRIGHT Figure 2 286°F(141°C) Blue 5b,6b,7b,9b 360°F(182°C) Mauve 4,5,6,8,9 N/A N/A Notes: 1. UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector-to-ceiling distance 2. C-UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector-to-ceiling distance 3. FM Approved for use in Light Hazard Occupancies at a 4 to 12 IN.(100 to 300 mm)top of deflector-to-ceiling distance 4. LPCB Approved(Ref.No.094a&007k)at a 4 to 6 in.(100 to 150 mm)deflector-to-ceiling distance 5. UL Listed for use in Light and Ordinary Hazard Occupancies 6. C-UL Listed for use in Light and Ordinary Hazard Occupancies 7. FM Approved for use in Light Hazard Occupancies 8. -PCB Approved(Ref.No.094a&007k) 9. Approved by the City of New York under MEA 354-01-E 10.Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as corrosion-resistant sprinklers. a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only N/A-Not Applicable TABLE A SERIES TY-B HORIZONTAL AND VERTICAL SPRINKLERS LABORATORY LISTINGS AND APPROVALS SPRINKLER FINISH K SPRINKLER TYPE NATURAL CHROME POLYESTER' LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED HORIZONTAL SIDEWALL (TY3351) 250 psi(17,2 bar)2 OR 5.6 RECESSED 175 psi(12,1 bar) 1/2 in. HORIZONTAL SIDEWALL NPT (TY3351) VERTICAL SIDEWALL 175 psi(12,1 bar) (TY3451) Notes: 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to UL Listing,C-UL Listing and Approval by the City of New York TABLE B SERIES TY-B HORIZONTAL AND VERTICAL SPRINKLERS MAXIMUM WORKING PRESSURE TFP161 Page 6of6 P/N 57 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH I RATING 578 HORIZONTAL SIDEWALL TY3351 1 NATURAL BRASS 135 135°F(57°C) 575 VERTICAL SIDEWALL TY3451 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) Notes: 3 PURE WHITE(RAL9010)2 93°C°F 1. Available for TY3351 only POLYESTER 200 200 ( ) 2. Eastern Hemisphere sales only 4 SIGNAL WHITE(RAL9003) 3. Available only for 155 T(68°C)or 200 T(93°C)temperature POLYESTER rated sprinklers 286 286°F(141-C) 4. Available only for horizontal sidewall TY3351 for use in Deluge JET BLACK(RAL9005)3 Systems("OPEN'indicates sprinkler assembly without glass 5 POLYESTER 360 360°F(182°C) bulb,button,and sealing assembly) 6 WAX COATED 286°F(141 °C)MAX 000 OPEN4 7 LEAD COATED 8 WAX-OVER-LEAD 286°F(141 °C)MAX 9 CHROME PLATED TABLE C SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Color Sprinkler Part Number Temperature Rating Black 135°F(57°C) 56-065-1-135 Red 155°F(68°C) 56-065-1-155 Yellow 175°F(79°C 56-065-1-175 Blue 200°F(93°C) 56-065-1-286 286°F(141°C) TABLE D SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS WAX RETOUCHING STICK PART NUMBER SELECTION Li 1'n ited Sprinkler Assemblies with Wax Sticks NPT Thread Connections (for retouching wrench-damaged Warrant Specify: Series TY-13 (specify SIN), wax coating) Y (specify K-factor), (specify Horizontal Specify:(specify color,below)Colored For warranty terms and conditions,visit or Vertical Sidewall) Sprinklers with Coded Wax Stick for retouching www.tyco-fire.com. (specify) temperature rating, (specify) (specify temperature rating) tempera- finish or coating, P/N(Refer to Table C) ture-rated Series TY-13 Sprinklers, P/N Ordering Recessed Escutcheon (specify) Specify: Style 10 Recessed Escutch- Note: Each wax stick is suitable for Procedure eon with(specify)finish, P/N(specify*) retouching up to 25 sprinklers. Contact your local distributor for avail- *Refer to Technical Data Sheet TFP770 Note: The wax used for 286°F (141°C) ability.When placing an order, indicate Sprinkler Wrench sprinklers a the sameasthr200°F(93°C) the full product name and Part Number Specify: W-Type 6 Sprinkler Wrench, sprinklers,and,therefore,th me maxima ) (P/N). P/N 56-000-6-387 sprinkler is limited to the same maximum ceiling temperature as the 200°F(93°C) Specify: W-Type 7 Sprinkler Wrench, sprinkler(i.e., 150°F[66°C]). P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a reglstered trademark of DuPont tqCU Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB 5 . 6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response , Standard Coverage ment provided by the Recessed Es- General cutcheon reduces the accuracy to which the fixed pipe nipples to the De s c rip t i o n sprinklers must be cut. The Series TY-FRB, 5.6 K-Factor, Corrosion resistant coatings, where r Horizontal and Vertical Sidewall Sprin- applicable, are utilized to extend the �T klers described in this data sheet are life of copper alloy sprinklers beyond quick response - standard coverage, that which would otherwise be ob- decorative 3 mm glass bulb type spray tained when exposed to corrosive at- sprinklers designed for use in light and mospheres. Although corrosion resis- ordinary hazard,commercial occupan- tant coated sprinklers have passed the cies such as banks, hotels, shopping standard corrosion tests of the appli- malls, etc. They are designed for in- cable approval agencies,the testing is stallation along a wall or the side of a not representative of all possible cor- beam and just beneath a smooth ceil- rosive atmospheres. Consequently, it ing. Sidewall sprinklers are commonly is recommended that the end user be used instead of pendent or upright consulted with respect to the suitability ; sprinklers due to aesthetics or building of these coatings for any given corro- construction considerations, where sive environment.The effects of ambi- piping across the ceiling is not desir- ent temperature, concentration of - able. chemicals, and gas/chemical velocity, should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the " TY-FRB Horizontal Sidewall Sprinkler chemical to which the sprinklers will be is intended for use in areas with a exposed. finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch WARNINGS (12,7 mm) of recessed adjustment or The Series TY-FRB Sprinklers de- up to 3/4 inch(19,1 mm)of total adjust- scribed herein must be installed and ment from the flush sidewall position, maintained in compliance with this or a two-piece Style 20 Recessed Es- document, as well as with the applica- T e c h n 1 c a 1 cutcheon with 1/4 inch (6,4 mm) of ble standards of the National Fire Pro- recessed adjustment or up to 1/2 inch tection Association, in addition to the Da t c`i (12,7 mm)of total adjustment from the standards of any other authorities hav- flush sidewall position. The adjust- ing jurisdiction. Failure to do so may Approvals impair the performance of these de- UL and C-UL Listed. vices. FM, LPCB, and NYC Approved. The owner is responsible for maintain- (Refer to Table A for complete ap- ing their fire protection system and de- proval information including corrosion IMPORTANT vices in proper operating condition. resistant status.) The installing contractor or sprinkler Maximum Working Pressure Always refer to Technical Data manufacturer should be contacted Sheet TFP700 for the "INSTALLER with any questions. Refer to Table B. WARNING" that provides cautions Discharge Coefficient with respect to handling and instal- K= 5.6 GPM/psis/2 (80,6 LPM/barli2) lation of sprinkler systems and com- Model/Sprinkle r Temperature Ratings ponents. Improper handling and in- stallation can permanently damage Id e n t ifi c a t i o n Refer to Table A. a sprinkler system or its compo- Finishes nents and cause the sprinkler to fail Numbers Sprinkler: Refer to Table A. to operate in a fire situation or cause Recessed Escutcheon:White Coated, it to operate prematurely. TY3331 - Horizontal Chrome Plated, or Brass Plated. TY3431 - Vertical Page I of 6 APRIL, 2006 TFP176 Page 2 of 6 TFP176 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL I CHROME WHITE— LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,3,4,9, 10 1,2,3,9 1,2,3,9 (TY3331) 175°F/79°C Yellow 200°F/93°C Green 5.6 286°F/141°C Blue 1/2" NPT RECESSED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,4,9, 10 1,2,9 N/A (TY3331)* 175°F/79°C Yellow Figure 3 200°F/93°C Green RECESSED 135°F/57°C Orange HORIZ. 155°F/68°C Red SIDEWALL 1,2,3,4,9 N/A (TY3331)" 175°F/79°C Yellow Figure 4 200°F/93°C Green VERTICAL 135°F/57°C Orange SIDEWALL 155°F/68°C Red 5.6 (TY3431) 5,6,7,8,9 5,6,7,9 1/2" Installed 175°F/79°C Yellow NPT Pendent 200°F/93°C Green or Upright 286°F/141°C I Blue NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 2.Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector to ceiling distance. 4.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04)at a 4 to 6 inch (100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5.Listed by Underwriters Laboratories, Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6.Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06&007a/04)as Quick Response Sprinklers. 9.Approved by the City of New York under MEA 354-01-E. 10.Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06)at a 4 to 6 inch(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)3/4"Total Adjustment Recessed Escutcheon. Installed with Style 20(1/2"NPT) 1/2"Total Adjustment Recessed Escutcheon. Frame and deflector only. Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Y Physical Characteristics @ Frame . . . . . . . . . . . . . Bronze Op era t i o n Button . . . . . . . . . Brass/Copper Sealing Assembly . . . . . . . . . . The glass Bulb contains a fluid which . . . . . Beryllium Nickel w/Teflont expands when exposed to heat.When a Bulb . . . . . . . . . . . . . . . Glass the rated temperature is reached, the Compression Screw . . . . . Bronze fluid expands sufficiently to shatter the HSW Deflector . . . . . . . . Bronze glass Bulb, allowing the sprinkler to Of VSW Deflector . . . . . . . . Copper activate and water to flow. o Patents a. U.S.A. 5,810,263 0 TFP176 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3331) OR 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 5.6 RECESSED HORIZ. 1/2" SIDEWALL(TY3331) (SEE NOTE 1) N/A NPT VERTICAL SIDEWALL (TY3431) 175 PSI (12,1 BAR) NOTES: 1.The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories, Inc. (UL);the Listing by Underwriters Laboratories, Inc.for use in Canada(C-UL); and,the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE De s ign * Temperature rating is DEFLECTOR indicated on deflector or HAT [H. Cri t e ri a adjacent to orifice seat on frame. The Series TY-FRB Horizontal and **Pipe thread Vertical Sidewall Sprinklers are in- connections per ISO 7/1 tended for fire protection systems de- can be provided on \ signed in accordance with the stand- special request. and installation rules recognized by the 6 2 3 1 applicable Listing or Approval agency WRENCH 1/2"** (e.g., UL Listing is based on the re- 9/16" quirements of NFPA 13, and FM Ap- (14,3 mm) FLATS NPT proval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. 1-13/16" 7/16" (46,0 mm) 17 (11,1 mm) CENTERLINE NOMINAL OF SPRINKLER MAKE-IN WATERWAY 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) 1 -Frame STYLE ESCUTCHEON 2-Button PLATE SEATING 3-Sealing 10 or 20 Assembly RECESSED SURFACE 4-Bulb ESCUTCHEON 5-Compression Screw 6-Deflector 2-7/8"DIA. (73,0 mm) FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331)SPRINKLERS Page 4 of 6 TFP176 Ins t o Ha L i o n ARROW MUST POINT AWAY The Series TY-FRB Sprinklers must 7/16" FROM AND BE 0 be installed in accordance with the fol- ESCUTCHEON (11,1 mm) PERPENDICULAR lowing instructions: PLATE SEATING 1/2„** NOMINAL TO THE BACK NOTES SURFACE NPT MAKE-IN WALL SURFACE Do not install any bulb type sprinkler if *6 the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler 5 held horizontally, a small air bubble 2-3/16" 2-3116" should be present. The diameter of the (55,6 mm) (55,6 mm) 4 air bubble is approximately 1116 inch (1,6 mm) for the 135°F/57°C to 3132 1-1/2" WRENCH 2 inch (2,4 mm) for the 286°F/141°C (38,1 mm) FLATS �; A temperature ratings. 7 3 r, A leak tight 112 inch NPT sprinkler joint �+ should be obtained with a torque of 7 1 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- SHOWN SHOWN CROSS mum of21 ft. lbs. (28,5 Nm)of torque PENDENT UPRIGHT SECTION may be used to install sprinklers with 112 NPT connections. Higher levels of torque may distort the sprinkler and 1 -Frame 3-Sealing 4-Bulb 6-Deflector cause leakage or impairment of the 2-Button Assembly 5-Compression 7-Ejection Spring sprinkler. Screw Do not attempt to make-up for insuffi- cient adjustment in the escutcheon * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. plate by under- or over-tightening the **Pipe thread connections per ISO 7/1 can be provided on special request. sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 The Series TY-FRB Horizontal and 5.6 K-FACTOR QUICK RESPONSE Vertical Sidewall Sprinklers must be SERIES TY-FRB VERTICAL SIDEWALL (TY3431)SPRINKLERS installed in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- Step B.After installing the Style 10 or way perpendicular to the back wall and 20 Mounting Plate over the sprinkler Care a n d parallel to the ceiling.The word"TOP" threads, hand tighten the sprinkler into on the Deflector is to face towards the the sprinkler fitting. Ma In t e n a n C e ceiling. Step C. Tighten the sprinkler into the The Series TY-BFR Sprinklers must Vertical sidewall sprinklers are to be sprinkler fitting using only the W-Type be maintained and serviced in accord- installed in the pendent or upright po- 7 Recessed Sprinkler Wrench (Ref. ance with the following instructions: sition with the arrow on the Deflector Figure 6). With reference to Figure 1, pointing away from the wall. the W-Type 7 Recessed Sprinkler NOTES Step 2. With pipe thread sealant ap- Wrench is to be applied to the sprinkler Before closing a fire protection system plied to the pipe threads, hand tighten wrench flats. main control valve for maintenance the sprinkler into the sprinkler fitting. Step D. After the ceiling has been in- work on the fire protection system that Step 3. Tighten the sprinkler into the stalled or the finish coat has been ap- it controls, permission to shut down sprinkler fitting using only the W-Type plied, slide on the Style 10 or 20 Clo- the affected fire protection system 6 Sprinkler Wrench (Ref. Figure 5), sure over the Series TY-FRB Sprinkler must be obtained from the proper With reference to Figure 1 or 2, the and push the Closure over the Mount- authorities and all personnel who may W-Type 6 Sprinkler Wrench is to be ing Plate until its flange comes in con- be affected by this action must be no- applied to the wrench flats. tact with the ceiling tified. The Series TY-FRB Recessed Hori- The owner must assure that the sprin- zontal Sidewall Sprinklers must be klers are not used for hanging of any installed in accordance with the follow- objects; otherwise, non-operation in ing instructions. the event of afire or inadvertent opera- tion may result. Step A. Recessed horizontal sidewall Absence of an escutcheon, which is sprinklers are to be installed in the used to cover a clearance hole, may horizontal position with their centerline delay the time to sprinkler operation in of waterway perpendicular to the back a fire situation. wall and parallel to the ceiling. The word "TOP" on the Deflector is to face Sprinklers that are found to be leaking towards the ceiling. or exhibiting visible signs of corrosion TFP 176 Page 5 of 6 5/8±1/4" (15,9±6,4 mm) FACE OF Z(END ENCH RECESS MOUNTING SPRINKLER NPT MODELS) SURFACE FITTING FIGURE 5 CLOSURE W-TYPE 6 SPRINKLER WRENCH 2-7/8"DIA. (73,0 mm) WRENCH SERIES RECESS TY-FRB 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8" PUSH WRENCH (3,2 mm) IN TO ENSURE ENGAGEMENT 1-1/4"(31,8 mm) 3/4"(19,1 mm) WITH SPRINKLER WRENCHING AREA 3/4"(19,1 mm) 1/4"(6,4 mm) FIGURE 3 FIGURE 6 SERIES TY-FRB RECESSED HORIZONTAL S/DEWALL SPRINKLER W-TYPE 7 RECESSED WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT SPRINKLER WRENCH STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" must be replaced. (12,7±3,2 mm) Automatic sprinklers must never be painted, plated, coated or otherwise MOUNTING FACE OF altered after leaving the factory. Modi- SURFACE SPRINKLER fied sprinklers must be replaced. FITTING Sprinklers that have been exposed to corrosive products of combustion, but have not operated,should be replaced CLOSURE if they cannot be completely cleaned by wiping the sprinkler with a cloth or 2-7/8"DIA. by brushing it with a soft bristle brush. (73,0 mm) Care must be exercised to avoid dam- SERIES age to the sprinklers - before, during, TY-FRB 2-1/4"DIA. and after installation. Sprinklers dam- (57,2 mm) aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler MOUNTING that has a cracked bulb or that has lost PLATE liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- 1/8" ommended to be initially performed for (3,2 mm) corrosion resistant coated sprinklers, after the installation has been com- 1-1/4"(31,8 mm) 1/2"(12,7 mm) pleted,to verify the integrity of the cor- rosion resistant coating. Thereafter, 1"(25,4 mm) 1/4"(6,4 mm) annual inspections per NFPA 25 should suffice; however, instead of in- FIGURE 4 specting from the floor level,a random SERIES TY-FRB RECESSED HORIZONTAL S/DEWALL SPRINKLER sampling of close-up visual inspec- WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT tions should be made, so as to better STYLE 20 RECESSED ESCUTCHEON determine the exact sprinkler condi- tion and the long term integrity of the Page 6 of 6 TFP176 P/N 57 - XXX - X - XXX SPRINKLER TEMPERATURE MODEL/SIN RATING 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F/57°C 375 VERTICAL SIDEWALL TY3431 4 WHITE POLYESTER 155 155°F/68°C 3 WHITE RAL9010)* 175 175°F/79°C 9 CHROME PLATED 200 200°F/93°C 7 LEAD COATED 286 286°F/141°C TABLE C 'Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS corrosion resistant coating, as it may standards of any other Authorities be affected by the corrosive conditions Having Jurisdiction. Materials found Ord e rin g present. by TFBP to be defective shall be either repaired or replaced, at TFBP's sole Procedure The owner is responsible for the in- option. TFBP neither assumes, nor spection, testing, and maintenance of authorizes any person to assume for it, When placing an order, indicate the their fire protection system and de- any other obligation in connection with full product name. Refer to the Price vices in compliance with this docu- the sale of products or parts of prod- List for complete listing of Part Num- ment, as well as with the applicable ucts.TFBP shall not be responsible for bers. standards of the National Fire Protec- sprinkler system design errors or inac- Contact your local distributor for avail- tion Association (e.g., NFPA 25), in curate or incomplete information sup- ability. addition to the standards of any other plied by Buyer or Buyer's repre- authorities having jurisdiction. The in- sentatives. Sprinkler Assemblies with NPT stalling contractor or sprinkler manu- In no event shall TFBP be liable, in Thread Connections: facturer should be contacted relative contract, tort, strict liability or under Specify: (Specify Model/SIN), Quick to any questions. any other legal theory, for incidental, Response, (specify K-factor), (specify It is recommended that automatic indirect,special or consequential dam- temperature rating), Series TY-FRB sprinkler systems be inspected, ages, including but not limited to labor (specify Horizontal Sidewall or Vertical tested, and maintained by a qualified charges, regardless of whether TFBP Sidewall) Sprinkler with (specify type Inspection Service in accordance with was informed about the possibility of of finish or coating), P/N (specify from local requirements and/or national such damages, and in no event shall Table C). codes. TFBP's liability exceed an amount equal to the sales price. Recessed Escutcheon: Specify: Style (10 or 20) Recessed Lim i t e d The foregoing warranty is made in lieu Escutcheon with (specify*) finish, P/N of any and all other warranties. ex- (specify*). Wa rra n t y press or implied, including warranties of merchantability and fitness for a par- *Refer to Technical Data Sheet TFP770. Products manufactured by Tyco Fire& ticular purpose. Building Products (TFBP) are war- This limited warranty sets forth the ex- Sprinkler Wrench: ranted solely to the original Buyer for clusive remedy for claims based on Specify: W-Type 6 Sprinkler Wrench, ten (10)years against defects in mate- failure of or defect in products, materi- P/N 56-000-6-387. rial and workmanship when paid for als or components, whether the claim Specify: W-Type 7 Sprinkler Wrench, and properly installed and maintained is made in contract, tort, strict liability P/N 56-850-4-001. under normal use and service. This or any other legal theory. warranty will expire ten (10) years from date of shipment by TFBP. No This warranty will apply to the full ex- warranty is given for products or com- tent permitted by law.The invalidity, in ponents manufactured by companies whole or part, of any portion of this not affiliated by ownership with TFBP warranty will not affect the remainder. or for products and components which have been subject to misuse,improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale, Pennsylvania 19446 AIR PRODUCTS OL Plus Series - Single Phase, Riser Mounted Air Compressors for Dry Pipe Sprinkler Systems O L UThis oil less riser mounted air compressor is UL1450 listed - oL Series for use in sprinkler systems. - UL1450 listed - Integrated Air Intake Filters - Oil Less Piston Compressor - Fully automatic, direct drive - UL Listed Pressure Switch - Max Pressure: 60 PSI - Bubble tight air check valve - 30" Stainless Steel Flex Hose - Permanently lubricated bearings - Riser Mounting Kit - Specifically designed to fill the sprinkler system to 40 PSI in 30 minutes MotorSystem Model Average 125 gal. OL12516AC 1.52 1/6 12 16" 12" 12" 30 250 gal. OL25033AC 3.03 1/3 12 16" 12" 12" 31 365 gal. OL36550AC 4.43 1/2 12 16" 15" 101, 38 430 gal. OL43075AC 5.21 3/4 10 17" 15"' 101, 48 615 gal. OL615100AC* 7.46 1 6 17" 15" 10" 48 915 gal. OL915150AC* 11.10 1 1/2 6 23" 15" 101, 60 1225 gal. OL1225200AC* 14.85 2 10 24" 15" 11" 70 Accessories: Notes: Air Maintenance Device- Part#AMD-1 + System Capacity based on 70°F system temperature. The AMD-1 regulates the volume of air being delivered ** Average CFM is the average free air delivery from q to the sprinkler system by the air compressor. 0 to 40 PSIG a Per NFPA 13-An Air Maintenance Device is required ++ Recommended Wire Sizes based on 100ft run. on every system unless the air compressor has a capacity less than 5.5 ft3/min at 10 psi. consult factory for longer or shorter runs. * Compressor has a capacity above 5.5 CFM at 10 PSI. Motor Line Starters - Thermal Overload Protection Air Maintenence Device required per NFPA 13 Single Phase VOLTAGE-All Single Phase Units 115 or 208-230 Volt 115V 208/230V Size Model except OL1225200AC which is 208-230 only. 1/3 HP 1 HP 00 MGOOA Maximum 1 HP 2 HP 0 MGXOA QO H 2 HP 3 HP 1 MG01A 3 HP 5 HP 1P MG15A When Ordering a Motor Starter you must specify HP, Voltage - —� and Phase that is supplied to the motor. ®WARNING:Cancer and Reproductive Harm-www.o65wamings.ca.gov www.generalairproducts.com 1-800-345-8207 AIR PRODUCTS OL Plus Series - Single Phase Riser Mounted Fire Protection Air Compressor Electrical Cut Sheet OLThis oil less riser mounted air U� UL compressor is UL1450 listed Series for use in sprinkler systems. Factory Amperage (amps) Recommended ize .Model Nominal Wired Based on Run . . . - VoltageNumber HP Up 115 5 35 12 12 12 OL12516AC 1/6 115 208 2.3 16.1 12 12 12 230 2.5 17.5 12 12 12 115 7.4 51.8 12 12 8 OL25033AC 1/3 115 208 3.5 24.5 12 12 12 230 3.7 25.9 12 12 12 115 10 70 12 10 8 OL36550AC 1/2 115 208 4.9 34.3 12 12 12 230 5 35 12 12 12 115 11.6 81.2 12 10 6 OL43075AC 3/4 115 208 5 35 12 12 12 230 5.8 40.6 12 12 12 115 18 126 12 8 6 OL615100AC 1 115 208 7.7 53.9 12 12 12 230 9 63 12 12 12 115 16.6 116.2 12 8 6 OL915150AC 11/2 115 208 8.2 57.4 12 12 12 230 8.3 58.1 12 12 12 OL1225200AC 2 208-230 208 11.6 81.2 12 12 10 230 11 77 12 12 10 Note: Wire sizes are based on maintaining 90%of the nominal voltage at starting amps. Starting amps are assumed to be 6 times the SFA. Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor. Wire sizes listed are recommendations only. Consult the National Electric Code(NEC)and any applicable local electrical safety codes.The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code(NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 7 w A/R PRODUCTS OL Plus Series - Connection Diagram OA ' This oil less riser mounted air Z1�� UL compressor is UL1450 listed - Series for use in sprinkler systems. _ System Layout PRESSURE SWITCH MUST or. BE WIRED IN CIRCUIT TO INDUSTRIAL CONTROL COMPRESSOR Main DISCONNECT SWITCH Power 9 OFT WIRE RUN, TOTAL LENGTH RISER NOTES: 1.MOST MOTORS ARE MULTIPLE VOLTAGE.CHECK NAME PLATE FOR CORRECT INTERNAL CONNECTIONS FOR VOLTAGE BEING SUPPLIED TO UNIT. 2.ALL WIRING TO BE IN ACCORDANCE WITH THE APPLICABLE STATE.LOCAL,AND NATIONAL CODES SHOULD BE APPROVED BY AHI. AIR TO SYSTEM Pressure Switch Connection SWP60401 U-C SWP60601 U PRESSURE SWITCH for 1/6 - 1/2 HP for 3/4-2 HP POWER SUPPLY Diagram +�� M. . L23Note:Location of pressure switch varies based on Ll L2model.This is a general diagram of components.For Ehelp specific to your switch please contact General Air POWERProducts. I41 iSUPPLY RT2L2 aB Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor. Wire sizes listed are recommendations only. Consult the National Electric Code (NEC)and any applicable local electrical safety codes.The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code (NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 Fire SprinkLer Accessories 'I mc. Engineered Solutions Fire Department Connection — S.Og|e C|apper, Siamese Straight Specifications �� 09_000 Size:— 4^|PSOutlet (2)z8^Inlets Straight Pattern Material: � 4r �� �� alaerao~ � Finishes: Rough Brass ' poi|shed[hmme^^ � Pin Lugs: msT I0686x716T ecr s.0000xurp [F 2.9900x716T Om-new I0580x6TP Om-old 3.0930x0TP [cv 3.0780x8Tp Dayton I2340x6Tp DcT 3l250x7*T Description wovascoa.zaooxsTP m,po 3.0300x8Tp The Straight Pattern Fire Department Connection isUL Listed and FMApproved. OmT 3l250x5Tp Manufactured from solid brass*components to increase service Life.The single clapper pHx aoszoxaTP design features brass clapper and brass seats within a cast brass body.The 2'/2"inlets QST 3.0910x7Tp are pin Lug design for ease of use and compatibility with Local fireservice districts.Swivel Raleigh 3.3400»6Tp nichmona.slznxuTp gaskets are included.Breakable caps orplugs should be installed to protect threads and TsM 3.0750x6Tp prevent debris from being accidently introduced into the water way. App,ovab: InstalLation uL Listed aoop,i Installation of the Fire Department Connection is achieved with readily available jobsite pw Approved 900pg ^ tools.Prior to installation make sure the proper idend cation sign has been instaK c"","/"`�°^ w"tm,""°m°°,°,`,,,°m`/",°"^°dedonthe for hu man nipple.Coat male threads of4^|PS nipple Liberally with a suitable pipe thread sealant such ^Polished chrome n1sh only available for mST pin lugs. aspipeph'.Tighten FDC one full turn past hand tight.Make sure Fo[is aligned according to requirements. & <�> D0 NOT OVER TIGHTEN.0VERT|CHTEN|NG MAY CAUSE SEVERE STRETCHING AND LISTED— APPROVED -- POSSIBLE CRACKING OF THE OF THE FD[BODY. The information above/^believed wbe reliable and accurate,but meant for reference only.ppp/and its agents cannot be hew FPPI. responsible",liable for incidental ,consequential damages°,toss suffered by any person","result ofm"use",misuse"f""~f m./"m�*""=��m"*�"��="°w�m.m"�=u"�u��"""���"^our=���**t�"��,=�",/mow ImAnAS[Engineered Solution w assure that products and methods cruse are suitable w,w°intended purpose,and the preparation vrio,w installation,and the installation*executed properly and"="*m^t°existing code,regulations where applicable and accepted industry practices.nyo"are =**rai"*=the installation mth/,product,seek guidance from"n""uedinstaller. PROJECT INFORMATION APPROVAL STAMP Project: El Approved Address: El Approved as noted Contractor: F-1 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Fp-oszz page I pp'soo'09'000'0120220502 tqCOWorldwide Fire Protection Contacts www.tyco-fire.com Products Model AMP-1 Automatic Air Maintenance Device Pressure Reducing Type with Field-Adjustable Pressure Regulator General Technical Description Data The TYCO Model AMD-1 Automatic Air Approvals Maintenance Device is an automatic, UL and C-UL Listed _ field-adjustable, pressure reducing FM Approved device. It is used to control the pres- NYC Approved under MEA 206-02-E sure in a dry pipe sprinkler system,pre- Maximum Inlet Air(or Nitrogen) action system, or dry pilot line system Supply Pressure of a dry pilot actuated deluge or preac- 200 psi(13,8 bar) tion valve. IF' Field-Adjustable Outlet Pressure The Model AMD-1 Device is utilized Range in applications where there is a com- 5 to 70 psi(0,4 to 4,8 bar) pressed air (or nitrogen) source con- trolled at a higher pressure than the Assembly desired system pressure. Pressure Major components illustrated in Figure sources include plant air supplies with 1 are factory assembled with galva- Installation their own automatic compressor con- nized steel nipples and malleable iron trols or nitrogen supplies with single- pipe fittings. The TYCO Model AMD-1 Automatic stage, cylinder-mounted pressure Air Maintenance Device should be regulators. operation installed in the horizontal position as The Model AMD-1 Automatic Air Main- shown in figure 1, as well as in accor- tenance Device is a re-designation for The By-Pass Valve in the Model AMD-1 dance with the following instructions: the Central Model D-2, Gem Model Automatic Air Maintenance Device is F324, and Star Model S460. opened to quickly fill the system during freTRIM initial pressurization.Once the required Moisture build-up can adversely affect system pressure has been reached, performance. Suitable consideration ® the By-Pass Valve is closed and the must be given to the removal of exces- The Model AMD-1 Automatic Air Main- Air Supply Control Valve is left open to sive moisture from the compressed air tenance Devices described herein must place the Model AMD-1 Device in auto- supply. be installed and maintained in compli- matic operation. ance with this document and with the When there is a small leak in the 1. Make connections a minimum of applicable standards of the National system, the Pressure Regulator auto- 1/2 inch (DN15) pipe size between Fire Protection Association, in addi- matically maintains system pressure at the inlet air supply and the Model tion to the standards of any authorities the preset level.The 3/32 inch(2,4 mm) AMD-1 Device,as well as between l. having jurisdiction. Failure to do so orifice in the 1.The ctor Check Valve the Model AMD-1 Device and the may impair the performance of these limits the flow of air from the Pressure system to pressurize. devices. Regulator into the system to a value 2. Place a 1/2 inch(DN15),non-spring Owners are responsible for maintain- significantly less than that exhausted loaded, rubber-faced, swing-type ing their fire protection system and by the operation of a 5.6 K-factor check valve between the Model devices in proper operating condition. sprinkler. AMD-1 Device and the system to The installing contractor or sprinkler pressurize. A check valve of this manufacturer should be contacted type is provided in the air supply with any questions. trim of TYCO dry pipe valves, pre- action valves, and dry pilot trim. Page 1 of 4 AUGUST 2015 TFP1221 TFP1221 Page 2 of 4 2" 16-1/8"" _ (50,8 mm) (409,6 mm) 1/4" NPT BY-PASS VALVE GAUGE (NORMALLY TEST PORT CLOSED) V(82 4" 112" NPT P/N 46-047-1-004 mm) OUTLET CONNECTION (TO SYSTEM) 8-1/2" (215,9 mm) 1/2" NPT LABEL INLET CONNECTION (FROM COMPRESSED AIR SUPPLY) RESTRICTOR � � � i CHECK VALVE P/N 92-326-1-003 PRESSURE AIR SUPPLY REGULATOR STRAINER CONTROL VALVE (ADJUSTABLE) P/N 52-353-1-002 (NORMALLY OPEN) P/N 92-324-1-012 P/N 46-048-1-002 FIGURE 1 MODEL AMD-1 AUTOMATIC AIR MAINTENANCE DEVICE Setting 6. Open the Air Supply Control Valve 10. Open the control valve in the in the Model AMD-1 Device. air supply trim to the system to Procedure 7. While observing the relocated pressurize. pressure gauge, adjust the output 11. Open the Air Supply Control Valve The TYCO Model AMD-1 Automatic pressure of the Pressure Regula- in the Model AMD-1 Device. Air Maintenance Device must be tor. Pull the knob out and away 12. Open the By-Pass Valve in the set in accordance with the following from the Pressure Regulator body Model AMD-1 Device. instructions: and then slowly turn the knob 1. Determine the pressure that meets clockwise, as viewed from the 13. Close the By-Pass Valve after the the minimum requirements of the knob end of the Pressure Regu- system is pressurized to approxi- system to pressurize. lator, to increase pressure, and mately 5 psi(0,4 bar)less than the counter-clockwise to decrease minimum required system pres- 2. Close the Model AMD-1 By-Pass pressure. sure determined in Step 1. Valve,and close the Model AMD-1 When decreasing pressure,the air 14. After the system pressure sta- Air Supply Control Valve. pressure must be relieved down- bilizes, note the value and com- 3. Open the control valve in the air stream of the Pressure Regulator pare with the requirement. Re- supply trim of the system to pres- by temporarily opening the control adjust the Pressure Regulator, as surize and then reduce the system valve in the air supply trim of the required. air pressure to 0 psi. system to pressurize,assuming that 4. Close the control valve in the the system to pressurize is at 0 psi. LEM air supply trim of the system to After the Pressure Regulator is set, If the system was over-pressurized pressurize. push the knob in and towards the during manual fill, open a suitable 5. Remove the system pressure Pressure Regulator body to"snap" connection to the system and manu- gauge from its connection and it in a locked position. ally reduce the pressure to the desired temporarily install it in the 1/4 inch 8. Close the Air Supply Control Valve value. The Model AMD-1 Automatic Air NPT Model AMD-1 Gauge Test in the Model AMD-1 Device. Maintenance Device then automatically Port. maintains the preset system pressure. 9. Return the system air pressure The Restrictor Check Valve prevents gauge to its normal location. Re- the Pressure Regulator from bleeding install the 1/4 inch pipe plug in the down the system pressure. Before removing the plug,make certain Model AMD-1 Gauge Test Port. In order to minimize the time for system that the piping to which the Model Apply pipe-thread sealant spar- trip in the event of a sprinkler opera- AMD-1 Gauge Test Port is connected ingly to the plug threads only. tion, set the system pressure at the is at 0 psi. Failure to do so may result minimum required value. in personal injury or property damage. RM-17WRO in Before removing the pressure gauge, make certain that the piping to which the Model AMD-1 Gauge Test Port is connected is at 0 psi. Failure to do so may result in personal injury or prop- erty damage. TFP1221 Page 3of4 Care and Automatic sprinkler systems are rec- Limited ommend to be inspected, tested, Maintenance and maintained a qualified c Warranty Inspec- tion Service in accordance withth local The TYCO Model AMD-1 Automatic requirements and/or national code. For warranty terms and conditions,visit Air Maintenance Device must be main- The Model AMD-1 Device must be www.tyco-fire.com. tained and serviced in accordance with inspected quarterly in accordance with the following instructions,in addition to the following instructions: ordering any specific requirements of the NFPA. Any impairment must be immediately 1. Verify that the By-Pass Valve is closed. procedure corrected. 2. Close the Model AMD-1 Air Supply Contact your local distributor for avail- MUM Control Valve and clean out the 1/4 ability. When placing an order, indi- Before closing a fire protection system inch Strainer located at the inlet cate the full product name, including main control valve for maintenance to the Restrictor Check Valve. Be description and Part Number(P/N). work on the fire protection system sure to reinstall the strainer screen Model AMD-1 Device that it controls, obtain permission to er and tighten the cap securely. p Specify: Model AMD-1 Automatic Air shut down the affected fire protec- 3. Open the Model AMD-1 Air Sup- Maintenance Device,P/N 52-324-2-002 tion system from the proper authori- ply Valve and verify that the control ties and notify all personnel who may valve in the air supply trim to the Replacement Parts be affected by this action. system to pressurize is open. Specify:(description), P/N(specify per It is recommended that accumulated 4. Verify that the system pressure is Figure 1) moisture be removed from air supply essentially the same as the previ- moisture filtration equipment at least ously established requirement. If quarterly. More frequent inspections not, adjust the system pressure may be necessary in particularly humid as follows: environments. a. Close the system's main con- After placing a fire protection system trol valve and open the main in service, notify the proper authori- drain valve. If the system is so ties and advise those responsible for equipped, close the Accelera- monitoring proprietary and/or central for Control Valve. station alarms. b. Follow Steps 1 through 14 in Responsibility lies with owners for the the Setting Procedure section. inspection,testing,and maintenance of c. Slowly open the Accelerator their fire protection system and devices Control Valve, as applicable. in compliance with this document, as well as with the applicable standards of d. Slowly open the main con- the National Fire Protection Association trol valve. After water begins (for example, NFPA 25), in addition to to flow, slowly close the main the standards of any other authorities drain valve, then completely having jurisdiction.Contact the install- open the main control valve. ing contractor or sprinkler manufac- The Model AMD-1 Automatic turer regarding any questions. Air Maintenance Device is now ready for service. TFP1221 Page 4of4 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. tgg0 Fire Protection Products ES-A-Deringer 30 Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval — Representative DeringerTM 30 Double Check Detector Assembly 4. . Sizes: 2"** - 8" a The DeringerTM 30 Double Check Detector Assembly(DCDA-ll) • • ,, prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire Approved for Fire Protection,Waterworks, Plumbing, sprinkler systems when monitoring of unauthorized water and Irrigation Applications. use is required. Materials Features Valve Housing: 304 Stainless Steel •Integral shutoff valves indoor/outdoor application Valve Cover: 304 Stainless Steel •100%stainless steel housing SOV Disks: EPDM/304SS •Tamper-resistant test cocks SOV Shafts: 304 Stainless Steel •Patented Dual-actionTm check modules Bypass Spring 302 Stainless Steel - Poppet action at low flow SOV Bearings: Teflon®fluoropolymer/Bronze -Swing action at high flow Non-wetted Bolts: Grade 8 Zinc Plated •Lead Free* Bronze bypass components Check Disks: Silicone(NSF) •CuFt or gallons bypass meter Wetted Fasteners: 18-8 Stainless Steel •DCDA-II single check bypass Bypass Components: Lead Free Bronze •Silicone elastomer check discs Check Springs: 17-7 Stainless Steel •Prewired supervisory switches Check Pins: 17-7/18-8 Stainless Steel •Flange adapters available Check Seats: Noryl® Polymer(NSF) •IPS grooved ends O-rings: Buna-N (NSF) Bypass Internals: ABS Polymer(NSF) Specifications Pressure — Temperature The Deringer 30 Double Check Detector Assembly shall utilize two independent Dual-action check modules and two integral Temperature Range:33°F-140°F resiliently seated shut-off valves all of which shall be contained Working Pressure: 10-175psi within a single rigid valve housing constructed entirely of 304 stainless steel. Both integral shutoff valves shall include *The wetted surface of this product contacted by consumable pre-wired supervisory tamper switches contained within a water contains less than 0.25%of lead by weight. weatherproof actuator housing approved for both indoor and outdoor use. Dual-action check modules shall operate as a Teflon®is a registered trademark of The Chemours Company. "poppet style"check under low flow conditions, operate as Nory10 is a registered trademark of SABIC Global Technologies B.V. a"swing style"check under high flow conditions and utilize replaceable silicone elastomer sealing discs.Assembly test ONFiToTMM cocks shall be handle-less and operate via a tamper resistant The information contained herein is not actuator.Assembly shall have a single full access service port intended to replace the full product installa- and cover with an "inline" replaceable elastomer seal. The tion and safety information available or the bypass assembly shall include a meter registering either experience of a trained product installer.You gallons or cubic feet, a single check valve and required test are required to thoroughly read all installation cocks.Assembly shall be serviceable without special tools and instructions and product safety information approved for both horizontal and vertical applications. before beginning the installation of Ak this product. A M Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- E S. ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction, FIRE&WATERWORKS specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand = Rated Flow A=UL Tested O = 15 fps Flow Performance _ (Ipm) 379 757 1136 1514 1893 2271 2650 3028 18 124 a 16 2„/2„ 4" 110 14 3" 96 12 83 J 10 69 8 55 6 41 cn 4 28 2 14 a� 0 (kPa) 0 100 200 300 400 500 600 700 800 Specific orientation&agency flow characteristics available on website Rate of Flow (gpm) pm) 1514 3028 4542 6056 7571 9085 16 110 a 14 6 8" 96 12 83 0 10 69 J 8 55 6 41 4 28 2 14 a� 0 400 800 1200 1600 2000 2400 *Specific orientation&agency flow characteristics available on website Rate Of Flow (gpm) Standards AWWA C510-07 Compliant NSF/ANSI 372, UL CERTIFIED LEAD FREE Dimensions - Weights End Connections - IPS Groove for Steel Pipe: AWWA C606 - Flange Adapters: ANSI B16.1 Class 125 ssfF� Ht D H ®C US APPROVED AssE U SC � O �Hb APPROVED 1015 L W Size Model 2(2'/2)** 30 7.1 180 2.9 74 22.3 566 0.0 0 10.0 254 11.0 279 52 24 2'/2 30 7.1 180 2.9 74 18.7 475 0.0 0 10.0 254 11.0 279 47 21 3 30 7.4 188 2.9 74 18.7 475 0.0 0 10.3 262 11.0 279 49 22 4 30 7.9 201 3.1 79 18.7 475 0.2 5 11.0 279 11.0 279 51 23 6 30 10.1 257 4.5 114 25 726 1.0 25 14.6 370 16.9 429 99 45 8 30 10.4 264 5.4 137 31.0 787 1.8 46 15.8 401 13.8 351 150 68 **2"size utilizes a 2 1/2"assembly with 2 1/2"groove to 2"female NPT adapter and couplings.Adapter and couplings ship unassembled. AM E S FIRE&WATERWORKS A WATTS Brand USA:Backflow T:(978)689-6066•F:(978)975-8350•AmesFireWater.com USA:Control Valves T:(713)943-0688•F:(713)944-9445•AmesFireWater.com Canada: T:(905)332-4090•F:(905)332-7068•AmesFireWater.ca Latin America: T:(52)55-4122-0138•AmesFireWater.com ES-A-Deringer 30 1951 0 2020 Watts t t tllll &64mmys 20184019 � + Product Catalog Ap TABLE OF CONTENTS Sammys°for Wood .......................................................................................................................... 4 Sidewinder"for Wood....................................................................................................................... 5 Sammys Swivel Head" for Wood......................................................................................................5 Sammys°for Steel............................................................................................................................ 6 Sidewinder"for Steel........................................................................................................................ 7 Sammys Swivel Head'm for Steel....................................................................................................... 7 SammyX-PressO............................................................................................................................... 8 SammyX-Press SidewinderTM............................................................................................................ 8 SammyX-Press Swivel'm................................................................................................................... 9 Sammy X-Press It° Installation Tool ..................................................................................................9 Sammys°for Concrete................................................................................................................... 10 Sidewinder"for Concrete ................................................................................................................ 10 Sammys Swivel HeadT11 for Concrete................................................................................................11 Concrete/Wood Installation Kit........................................................................................................ 11 SammysToggleTM............................................................................................................................ 12 Dektite° Pipe Flashing..................................................................................................................... 12 Sammys X-Press° Pole Tool Kit...................................................................................................... 13 SammysPole TooITM......................................................................................................................... 13 Approvalsand Listings.................................................................................................................... 14 SpecialNotes .................................................................................................................................. 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used.Allowance for special characteristics in materials,differences in materials,differences in types of materials being joined,unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered.Due to possible differences in specifications,applications,and interpretation of results,purchasers and specifiers must make their own evaluation of the products,to determine the suitability of these products for intended use.All warranties of Buildex products,expressed or implied,including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following:Buildex will repair or replace any product which,within twelve months after sale by Buildex or its distributors,is found by Buildex to be defective in material or workmanship-normal wear and tear accepted.This is the sole warranty of Buildex and the sole remedy available to distributor or buyer.Buildex shall not be liable for any injury,loss or damage,direct,indirect,or consequential,arising out of the use of,or the inability to use,any Buildex product. INSTALLATION • • ' WOOD & STEEL INSTALLATION STEP INTO WOOD&STEEL: INSTALLATION STEP •' •MTO WOOD&STEEL: 1.Insert the appropriate nut driver into a 318"or 1/2°portable drill. 1.Insert the appropriate nut driver into a 318"or 112"portable drill. 2.Insert the SAMMYS®into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.Begin installation when the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins freely on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114"318",112"or metric all thread rod,bolt stock.(The 112"requires the#14SW red nut driver) 4.The unit is now ready to receive 114",318",M10,M8 or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximumpullout in purlin steel. Note:When installing SWDR,follow the above instructions,then add retainer nut and torque to 20 inch lbs.for maximum pullout in purlin steel. INSTALLATION • FOR CONCRETE INSTALLATION STEPS- =INTO CONCRETE: INSTALLATION STEPS = INTO CONCRETE: 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit,pre-drill the concrete member to a depth of 2"with a carbide tip bit,pre-drill the concrete member to a depth of 2"with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2.After pre-drilling has been completed,install the SLEEVE TOOL over 2.After pre-drilling has been completed,install the SLEEVE TOOL the bit(the bit should remain in the drill),and insert the#14(black) over the bit(the bit should remain in the drill),and insert the#14SW(red) nut driver(p/n 8113910)into the opposite end(see Vertical Installation nut driver(p/n 8114910)into the opposite end. note above). 3.Insert the SWC screw into the nut driver. 3.Insert the CST screw into the nut driver. 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill drill mode and begin insertion.When the nut driver spins free on the mode and begin insertion.When the nut driver spins freely on the SWC screw,installation is complete.Stop and remove drill. CST screw,installation is complete.Stop and remove drill. 5.The SWC screw is ready to receive 114"318"or metric all thread rod 5.The concrete screw is ready to receive 114",318°112",or metric all or bolt stock. thread rod or bolt stock.(#14SW red nut driver used with 112"screw) Note:Use a 1200 maximum RPM drill for installation. Note:Use a 1200 maximum RPM drill for installation. Note:Do not install concrete screws while the drill unit is in impact mode— Note:Do not install concrete screws while the drill unit is in impact mode— doing so will destroy the pullout factor of the fastener doing so will destroy the pullout factor of the screw. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 3 To find a distdbutor near you,call 800-848-5611 SAMMYS° FOR WOOD SAMMYS' FOR WOOD - Vertical Application Application Product Features Not less than Wood Flooring 2"nominal width •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill. thickness(2-1/2") (depth or side Wood Joist of vertical member) •Saves time from traditional - - - - - methods. Double Sheetrock Ceiling •Reduces installation costs. Assembled in the U.S.A. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-dtilfing may be required for GST N 25-380.Tool available on page 11. View our installation videos! OUT& Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Gty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 L 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 #14 Black 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 Nut Driver v 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Part#8113910 tg 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 If w � oHS ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 SIDEWINDER@ FOR WOOD -Horizontal ApplicationApplication o Product„ 5 Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5'pipe •Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. •Assembled in the U.S.A. :r View our installation videos! O YOUTUk HORIZONTALApprovals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Shear(Ibs) Load(Ibs) Gty QtY . VIL 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 Q. 3/8" 8022925 SWG 25-380 318 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL HEAD Tm FOR WOOD Swivel Application Application Product Features r..•an c.*00°.,,,.10", •Eliminates distortion of threaded rod. ", •Accommodates up to 3'%"x 12 pitch roof. •Allows 17°deflection from vertical. ..a •Saves time from traditional methods. •Reduces installation costs. �rre� •*. Assembled in the U.S.A.Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case • Size Number .• City e #14 Black SWIVEL MOUNT Nut Driver 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#81139101 1903 Dim.Lumber 1500 33/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 May require pre-drilling;consult joist manufacturer. Dim.Lumber #14 SH Orange ••will not swivel until installed with black nut driver. • Nut Driver Part#8273910 To find.distributor near y• 800-848-5611 SAMMYS® FOR STEEL SAMMYS' FOR STEEL - Vertical Application Application Product Features •Made with Teks®self-drilling fasteners- no pre-drilling required. •Installs into steel range from ` 20 gauge—1/2"thicknesses. �' •Saves time from traditional methods. •Reduces installation costs. •Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. •A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance,the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. ,► •Assembled in the U.S.A. P�►�.O�►JL� � View our installation videos! MuTube Approvals Rod Part Model Screw Ultimate ILL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x V TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4'. 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 _ 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 0 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-112"TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 �} 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 i 0 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) #14 Black 3/8" 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 Nut Driver Y 0 3/8" 8046957 TEK 50 12-24 x 1-112"TEKS 5 3125 (3/16") 1500 1475 .250"-l/4" 1/2" 25 125 Part#8113910 446 (20 ga.) .::--•� 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 g70 (16 ga.) .188"-3/16" 1/4" 25 125 .. 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 s � oHS 00"I ASSEMBLED U.S.A. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. ProductSIDEWINDERI FOR STEEL -Horizontal Application Application •Made with Teks°self-drilling fasteners-no pre-drilling required. NO •Installs into steel range from 20 gauge—1/2"thicknesses. }�� •A standard screwgun with a depth sensitive nosepiece should be used to install Teks.For optimal fastener performance,the screwgun should be a -- minimum of 6 amps and have an RPM range of 0-2500. Y0 •Saves time from traditional methods. J •Reduces installation costs. W •Quick to install using the Sammys Nut Driver with an View our W 18V cordless drill/driver. installation videos! •Asembled in the U.S.A. 0 YothbeApprovals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case y Size Number D- Qty Qty HORIZONTAL MOUNT 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 v 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8054957 SWDR 1-1/2* 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 3/8" 8056957 SWDR 516* 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 *Includes retaining nut #14 SW Red Nut Driver Part#8114910 SAMMYS SWIVEL .Tm • - STEEL Application Application Product Features •Eliminates distortion of threaded rod in sloped roof applications. r •Accommodates 3-1/2 x 12 pitch. • •Installs into angled z-purlin;allows threaded rod to hang plumb. •Allows 17°deflection from vertical. •Asembled in the U.S.A. 1 View our installation videos! CYoubbe Approvals Rod Part Model Screw Ultimate UL Test I'M Test Min Max Box Case Size Number •. Qty Qty SWIVEL MOUNT M #14Black " 81379 11TEK S 3 X 1" ( ) Nut 3/8 57 SH-DSTR 1* Driver TEK 3220 3/16" 1500 1475 .035" 3/16" 25 125 Nut Part#8113910 2368(1/2"steel Vertical) 3/8" 8268957 SH-TEK 50 12-24 x 1-5/8" 1306(45°off Vertical) 1500(Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281(3/16"HISS) 850(45°off Vertical) 2-1/2" 1585(3/16"HISS 45°off Vertical) *Does not comply with ROHS requirements/Includes retaining nut #14 SH Orange • Nut Driver Part#8273910 SA MMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel SAMMYX-PRESSOApplication ProductApplication •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: (XP) - light gauge steel deck or purlin •No retaining nut required. � (22 ga.-1/8"). •Provides design flexibility. •Installs in seconds with Sammy X-Press It®Tool, saving time&installation costs. •Assembledin the U.S.A. •Use in applications where access to the back of View our the installed fastener is prohibited.is.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. Woubbe DescriptionApprovals Rod Part Model Size Number Pullout(lbs) Load(lbs) Thick Load(lbs) Thick Thick • QtY MOUNTVERTICAL Sammy 185(Luminaire) .027 NL 1/4" 8181922 XP 200 X-P ess 200 1146(22 ga) 250(Luminaire) .056" .125" 25 125 Metal Deck ■ 850(2%"Pipe) .027" 940 (2"Pipe) 029" X-Press 20 250 3/8" 8150922 XP 20 Sammy 1146(22 ga) 250(Luminaire)(Luminaire) .0.056"" 1475(4"Pipe) .104" .125" 25 125 Metal Deck 283(Conduit&Cable) .029" 1500(4"Pipe) .060" 3/8" 8153922 XP 35 X Pr ss 35 1783(16 ga) 250(Luminaire) .056" 4775((4"PI pe) .1104" .125" 25 125 Purlin 416(Conduit&Cable) .059" T Pre-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22 ga) 850(2%Pipe) 25 125 (Pre-Pour) X-Press 20 Post-Pour Range II LWC<_35 PCF(lbs/ft3) Metal Deck (Post-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<_35 PCF(Ibs/ft') —J—�VVE Lr -�- Lr'� SAMMYX-PRESS SIDEWINDER'" - Horizontal Application Application Product •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. provide horizontal attachment in: 16 ga-3/16"steel-purlin,tubular steel. •No retaining nut required. •Installs in seconds with Sammy X-Press It®Tool, •Provides design flexibility. saving time&installation costs. •Assembled in U.S.A.of •Use in applications where access to the back of Canadian Steel the installed fastener is prohibited;ie.metal roof View our deck,tubular steel,or vapor barrier fabric. installation videos! 0 Youbbe DescriptionApprovals Rod Part Model Size NumberShear(Ibs) Load(lbs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT 1250(3%'Pipe) 3/8" 8293957 SWXP 35 Sidewinder 1798(16 ga) 80 (Luminaire) .059" .125" 25 125 Metal rlin in X-Press 35 416(Conduit&Cable) Pu � S ASSEMBLER U.S A. TM SAMMYX-PRESSA . . ProductApplication •The Sammy X-Press Swivel allows you •Less jobsite material needed. to hang plumb in extreme roof pitches: 89*in z-purlin •No retaining nut required. 45'in metal deck for 12/12 pitch � •Provides design flexibility. EREM •Installs in seconds with Sammy X-Press It®Tool, f)10' n 1 G saving time&installation costs. •Assembled in the U.S.A. V�p1�NT •Use in applications where access to the back of View our the installed fastener is prohibited.ie.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. MOW— O — DescriptionApprovals Rod Part Model Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty MOUNTSWIVEL 750(2"Pipe) Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) Metal Deck/ 3/8" 8294922 SXP 20 80 @ 45°(Luminaire) .029" 635(2"Pipe) .029" .125" 25 125 X-Press 20 829(45°Off Vert) 283 Vertical(Conduit&Cable) Pudin 11J 233 @ 45°(Conduit&Cable) 'W 1250(3-1/2"Pipe) 250 Vertical(Luminaire) ? 3/8" 8295922 SXP 35 Swivel 1675(16 ga Vert) 80 @ 90°(Luminaire) '059° '029" .125" 25 125(Luminaire) Metal Deck/ X-Press 35 1558(89°Off Vert) 500 Vertical(Conduit&Cable) 635(2"Pipe) Purlin 333 @ 89°(Conduit&Cable) 1/2" 8272957 SXP 2.0 Swivel 1061(22 ga Vert) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vert) Pudin 1/2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) Metal Deck/ X-Press 3.5 1558(89°Off Vert) .060" .125" 25 125 Pudin • SAMMYX- - - © • • • Application Product ` •The Sammy X-Press expands to provide direct vertical attachment in: metal deck(22-16 gauge) y4 J t z-purlin(18-16 gauge) •Assembled in the U.S.A. View our installation videos! 0 Youbbe DescriptionPart Number Model 8194910 UXPIT* Universal X-Press It Tool 1 8152910 XPDB 25/64"Drill Bit 1 'Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. 1 1 • To find-distributor near y• 800-848-5611 SAMMYS° FOR CONCRETE SAMMYS@ FOR CONCRETE — Vertical Application Application Product Features •Easy two step process(Drill hole& *•4��'4 ,d o d v; �•4,'Q drive Sammys concrete anchor). ?" 'a r 4?" a •1W pre-drilled pilot hole required. . 7 ` .D `ad•`aJ�A�• :d `pd• •� •Concrete Installation Tool available for CC a one tool installation process. •Assembled in the U.S.A. -j .f••'ft••r ••r•' � j•• fir View our ... installation videos! 0YOUTUbe Size Number Descriptions Pullout(lbs)* Load(lbs)Approvals Rod Part Model Screw Ultimate I'M Test Box Case VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Part#8113910 — #14SW Red 1/2" 8060925 CST 2 5/16 x 1-3/4" 2400 25 125 Nut Driver FM 36-EFM 3/8" 8306957 CCST 516 5116-14 x 2-1/2" 857** 25 125 Part#8114910 For complete performance data see ICC Report ESR-3699 Tested in 3000 PSI concrete **Pullout strength for Cracked Concrete and Seismic Zones A-F ProductSIDEWINDEW FOR CONCRETE - Horizontal Application Application �' •Easy two step process(Drill hole&drive •4• U°• Sammys concrete anchor). � I I • C p '�' o'P Z •'/<"pre-drilled pilot hole required. •Concrete Installation Tool available for a one tool D., -p. • C installation process. d ri ol77`4; , a o � •Assembleded in the U.S.A. View our installation videos! OYNTUM Approvals Rod Part Model Screw Ultimate FM Test Box Case Size Number 1• Qty Qty HORIZONTAL MOUNT 0 3/8" 8061957 SWC 20 5/16 x 1-3/4" 2450 1475 25 125 O 369gEFM 3/8" 8307957 SW-CCST 516 5/16-14 x 2-1/2" 857** 25 125 #14SW Red Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Nut Driver Part#8114910 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.ASSEMBLED U.S.A. �S free.Installation n t onis then complete.rWarranty requires thecuse ltof the appropriate nut driver for installations.continue drilling until nut driver spins OZZHH'yo SAMMYS SWIVEL HEAD Tm FOR CONCRETE Swivel Application Application Product Features •Installs vertically and swivels up to 89°in wood& concrete structures. •:moo s..�:=.P' Eliminates distortion of threaded rod. •1/4"pre-drilled pilot hole required. •Concrete installation tool available for a one piece installation process. •Assembled in the U.S.A. Approvals Rod Part Model Screw Ultimate Box Case Size Number .• Qty Qty SWIVEL MOUNT 2537 in 3000 psi concrete 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1459 @ 45°off vertical in 3000 psi concrete 25 125 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete FM 3/8" 8308957 SH-CCST 516 5/16-14 x 2-1/2" 857** 25 125 Note:UL Listed for wood-see page 5 #14 SH Orange Nut Driver Part#8273910 *Tested in 3000 PSI concrete **Pullout strength for cracked concrete and Seismic Zones A-F Uj CONCRETE I WOOD INSTALLATIONLLI Ct V Application Z 'CRotary Hammer Drill into concrete Hammer Drill into concrete (b) b (9) (d) (h) (gam (e) (h) -sepiao, (C) (c) (a) Part Number Description Each Qty • 8122910 Concrete Installation Kit(a) 1 Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 8114910 #14 SW Red Nut Driver(c) 1 8116910c #250 Bit(1/4")(d) 1 8117910 SIDS Bit(1/4")(e) 1 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 8098910 SL 250 Sleeve(h) 1 To find a distributor near you,call 800-848-5611 ACCESSORIES SAMMYS TOGGLE TM Application Installation Steps 1.Pre-drill a 5/8"hole with a regular drill or hole saw. 4N, 2.Insert SST screw into#14 black nut driver.With wing nut and washer on bolt,insert wing nut through surface,and begin J installation. 3.When bolt is secure and nut driver spins free,stop drill motor and remove. Pre-Cast Hollow Core 4.SST screw is now ready to receive 114",3/8",or Metric all Concrete thread rod or bolt stock. o. r D• e ty 'Size Part Number Model • 450 (Lath&Plaster)' 3/8" 8064925 SST 30 1/4 x 3" 404 (2 Layers 5/8 Rock) 25 125 #14 Black Nut Driver Part#8113910 PIPE Application ,r •Complies with NFPA 13 Code Changes. •Flashing for dry pendant sprinklers subject to 4-f�RTITE 51 AY �p TO extreme temperature changes. CODE s •One piece construction is easy to install. --- with a qui<har, •Pipe diameter markings ensure accurate fit. U ARM more efficient war HOLE to fl4sh your •EPDM temperature range of-65OF to+250°F. refri9crationifreaicy units. tresrtUlTEo FREEZER STRUCTURE t—Nn fif>fU�118 Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4003910 1 1/4"-2" 4-3/4" 3" 10 4004910 2 1-3/4"-3-1/4" 6-1/4" 4" 10 . 1. - 1 11. 611 11. oil SAMMYX-PRESS POLE TOOL • Application Product Features Speed your labor by 25% Work from the ground up It �w No scaffolding,ladders,or lifts v Perfect for working in tight spaces,through ceiling grid, --— and high vaulted ceilings For use installing Works with any Sammy X-Press product t Sammy X-Press anchors from the ground up! View our installation videos! p YouTube r Part Number Model Description Box Qty 1 XPKIT* XPKIT Sammy X-Press Pole Tool Kit 1 3/4"electdcal conduit needed for pole tool assembly • ji• SAMMYS �. POLE TOOL TIM Installation , Product Speed your labor by 25% 1 2 3 Insert •Work from the ground up adjust! here No scaffolding,ladders,or lifts Perfect for working in tight spaces,through ceiling grid, Adjust the Pole Tool to length. Load rod and Sammys into The socket will spin free and high vaulted ceilings The adjusting pin must be 18" Pole Tool. when the screw is completely below the base or the pin may installed.Pull down to remove •Works with any Vertical SAMMYS:Wood,Steel,or interfere with the rod. the Pole Tool. Concrete • Part Number Description Box Qty Pole 6'-18' 1 W W O 0 W V V Q • APPROVALS Part Numberr . ..• Mount UL Max ULTest UIL Min Wood FM Max FM Test FM Min Wood _ 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2' 8068925 GST20-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-112' 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG25-380 3/8" Horizontal 3-1/2"-4"* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3"** 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45"Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1475 1-1/2" SAMMYS FOR STEEL-PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 318" 17'Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK50 3/8" Vertical 2-1/2" 850 70*Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical or up to 89' 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE-PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC<_35 PCF(lbs/fC) Part Model .. Mount UL Load UL Min Steel SAMMYS Number Size Direction Rating(Ibs) Thickness 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 318" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8' Vertical 170 .027" 45' 80 .027" 8295922 SXP 35 3/8' Vertical 250 .060" 90* 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" Part Model Rod Mount UL Load UL Min.Steel Listed Application Number Size Direction Rating(Ibs) Thickness SAMMYS FOR CONDUIT, 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 1/4"or 3/8" Onto Vertical Rod UL Listed 4S16-Cable Hanger,Cat.No.C-Z2000 Plenum Rated, Complies w/NEC Standards GaugesSheet Steel Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber orjoist allowed by UL is 4" UL and FM tests were performed in compliance with NFPA 13 Standards. **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. **SWG 20 Maximum pipe size in wood timber or'oisl allowed to UL is 3" SPECIAL NOTES • Engineering Note • In 1996,the anchors listed by UL were tested in plate steel that measured.188"and.118".Subsequent testing was done for z-purlin applications in May 1997 using(.037")or 20 gauge steel.Most recently in 2008,testing with the new Sammy X-Press®was completed using(.030")or 22 gauge steel metal deck. Sammys®Nut Drivers Special nut drivers were designed to be used with Sammys.When the appropriate nut drivers are used for installation,the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure. Steel Screws Due to variations in hardness of certain metals,it should be noted that our self-drilling screws for steel will experience different drill speeds.500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist.UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a composite joist.Penetration of the upright center web is permitted by some joist manufacturers.Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot hole 1/8"smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8" GST 25-380 .280" 7132" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers,and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards.Check with your local(AHJ)Authority Having Jurisdiction to confirm application and usage. UL Listings/FM Approvals UL and FM reports are available at www.itwbuildex.com �uLD 5 O • 111B RAKER ALSO LISTED AS CONDUIT AN O CABLE HARD WARE ALSO USMB AS ANCHOR FOR LUMINAIRE B., Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats:.dwg,.dxf,and.igs. Assembled in the U.S.A. Products Contact Information As—bledUSA Technical Assistance:(800)848-5611 Option#6(x 3259) Customer Service:(800)848-5611 Option#1 • J Q Q. Q. Q 15 To find a distributor near you,call 800-848-5611 Angle Hose Valves 111S1S7r--0L FPPI° Description Angle hose valves feature all brass"construction with forged or cast bodies '' for rigidity and light weight. Typical uses are in rack assemblies or any other application which requires a listed fire hose valve. Available in rough brass or polished chrome finish with a red hand wheel. UL, ULc Listed, FM Approved. Rated 300psi Installation Specifications Install in accordance with customary installation practices. Use an approved thread sealant such as PipeFit°Thread Sealing Paste with PTFE on the male Material: Cast or Forged Brass Body threads to which the valve is being installed. Finish: DO NOT OVER TIGHTEN. Over tightening of the valve during installation Rough Brass Polished Chrome* to the male pipe threads may crack or deform the valve body. Only use tools suitable for the installation of this product. Do not use pipe wrench Threads: extenders to increase leverage on pipe wrenches. This may result in valve 2 1/2" FNPT x FNPT damage as well as personal injury. x MNST x MBCT x MQST x MONT x MPHX x MTEM x MCLV x MNYFD x MDET x MCF x MRCH 21/2" GRV x FNPT x MNST x MQST x MNYFD 2 1/2" FNPT x 3 MNST The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance 1 1/2" FNPT x FNPT and information purposes only.FPPI and its agents cannot assume liability or responsibility for results obtained in the x MNST use or misuse of its product by persons whose methods and qualifications are outside and beyond our control.It is the user's responsibility to determine the suitability of,methods of use,preparation prior to use,and appropriate installation `Contains lead.Not for use in for all products purchased from FPPI.It is the user's sole responsibility to observe and adapt such precautions as may water systems intended for human be advisable or necessary for the protection of personnel and property in the handling and use of any of our products. consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 +1 (760)599-1168 +1 (800)344-1822 +1 (800)344-3775 FAX C ul us FM APPROVED ©2017 Fire Protection Products,Inc. 37WL TATA TT U1111fill IT, CO® Worldwide www.tyco-fire.com Contacts Model DPV4 Dry Pipe Valve External Resetting General Description The TYCO Model DPV-1 Dry Pipe Valves are differential valves used to automatically control the flow of water into dry pipe fire protection sprinkler systems upon operation of one or more I automatic sprinklers. The DPV-1 also provides for actuation of fire alarms r: upon system operation. The Model DPV-1 features are as follows: • External reset. • 250 psi (17,2 bar) pressure rating. • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. • Ductile iron construction to ensure Available Sizes and End Connections a lightweight valve to minimize ship- ping cost. Nominal Valve Size • A variety of inlet and outlet End Connection 2-1/2 in. 3 in. 4 in. 6 in. connections. (DN65) (DN80) (DN100) (DN150) • Compact, Pre-Trimmed, and Semi- Flange x Flange N/A N/A • Assembled, easy to operate valve Flange x Groove N/A N/A • trim. Groove x Groove • • Simple reset procedure through the .=Available elimination of priming water. N/A=Not Available Dry pipe sprinkler systems are used in unheated warehouses, parking INOTRIM Dry Pipe Valve garages, store windows, attic The Model DPV-1 Dry Pipe Valves The TYCO Model DPV-1 Dry Pipe spaces, loading docks, and other described herein must be installed Valves shall be installed in the verti- areas exposed to freezing tempera- and maintained in compliance with cal orientation only (supply at bottom tures, where water filled pipe cannot this document, as well as with the flowing upward)and are rated for use at be utilized. When set for service, the applicable standards of the National a maximum service pressure of 250 psi dry pipe sprinkler system is pressur- Fire Protection Association, in addition (17,2 bar). Valve and trim dimensions ized with air (or nitrogen). The loss of to the standards of any other authori- are shown in Figure 6. pressure through an operated auto- ties having jurisdiction. Failure to do so Flanged connections are available and matic sprinkler in response to heat may impair the performance of these drilled per ANSI,ISO,AS,and JIS spec- from a fire permits the DPV-1 Dry devices. ifications (Ref. Table A). The grooved Pipe Valve to open and allow a flow of outlet connections, as applicable, are water into the sprinkler system piping. The owner is responsible for main- cut in accordance with standard groove Table B establishes the minimum taining their fire protection system specifications for steel pipe. They are required system air pressure that and devices in proper operating con- suitable for use with grooved end pipe includes a safety factor to help prevent dition. Contact the installing contrac- couplings that are listed or approved false operations that might occur due for or product manufacturer with any for fire protection system service. to water supply fluctuations. questions. Available combinations of inlet and outlet connections are described in Technical Data the Ordering Procedure section and in IMPORTANT the Available End Connection and Sizes Refer to Technical Data Sheet Approvals table on page 1. TFP2300 for warnings pertaining to UL and C-UL Listed regulatory and health information. FM Approved Trim port connections of valves having NYC Approved flanges drilled to ANSI,AS,or JIS spec- Page 1 of 20 OCTOBER 2018 TFP1020 TFP1020 Page 2 of 20 NO. DESCRIPTION QTY. REF 1 Valve Body.......1 NR 2 Air and Water Seat . .. .... .....1 NR 3 Handhole Cover...1 NR 4 Handhole Cover Gasket . .........1 (b) 0-11 5 1/2-13 UNC x 1" Hex Head Cap Screw: 2-1/2&3 Inch 12 Valves.. .........5 CH 6 4 Inch Valve ......6 CH ® 13 6 Clapper. .........1 (a) 7 Clapper Facing....1 (a)or(b) 7 RESET 8 Clapper Facing CLAPPER 14 PLUNGER Retaining Plate....1 (a) ASSEMBLY ��8 PARTS 9 2-1/2 and 3 Inch Valves: 15,18 1/4"x Long Shoulder � #10-32 Shoulder 9 Screw.. .........5 (a) 16 4 Inch Valve: 1/4-20 UNC x 1/2" Socket Head Cap 17 Screw.. .........7 (a) 10 Clapper Hinge Pin .. .. .. .......1 (a) 11 Reset Knob ......1 (c)or(d) 12 Reset Spring .....1 (c) 0 13 Reset Bushing ....1 (c) 14 Reset Bushing O-Ring.. .........1 (b),(c)or(e) 15 Reset Plunger O-Ring . .. .......1 (b)or(c) 16 Reset Plunger.....1 (c) 17 Reset Latch I Subassembly .....1 (c) 18 Dow Corning FS3452 FlouroGrease, 1.5ne 1 Grease,1.5 g .....1 (b)or(c) 4 NR:Not Replaceable / 3 CH:Common Hardware 2 \ ® / REPLACEMENT PARTS NO. DESCRIPTION P/N / ® Q (a) Clapper Assembly Includes Items 6-10: I 0 Q 2-1/2&3 Inch Valves. . 92-310-2-203 4 Inch Valve ........ . 92-310-2-403 ® (b) Repair Parts Kit 10 Includes Items 0 5 4,7, 14,15,&18: 2-1/2&3 Inch Valves. . 92-310-1-204 4 Inch Valve ........ . 92-310-1-404 (c) Reset Plunger Parts Kit Includes Items 11-18. . 92-310-1-405 (d) Reset Knob, Item 11.. . 92-310-1-406 (e) Reset Plunger O-Ring,Item 15 ..... . 92-310-1-407 FIGURE 1 -PART 1 OF MODEL DPV-1 DRY PIPE VALVE 2-1/2,3,AND 4 INCH(DN65,DN80, DN100)ASSEMBLIES TFP1020 Page 3 of 20 NO. DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY. REP.PART 1 Valve Body.. ... ..1 NR 5 Socket Head Cap 8 Hex Head Cap Screw 2 Air and Water Screw 5/8-11 UNC x 1". ..6 CH Seat . .. .... ... ..1 NR 3/8-16 UNC x 1". . .8 NR 9 Clapper. .. .. ... ..1 (a) 3 Water Seal 6 Handhole Cover. ..1 NR 10 Clapper Facing.. ..1 (a)or(b) O-Ring . .........1 NR 7 Handhole Cover 11 Clapper Facing 4 Air Seal O-Ring....1 NR Gasket . .. .. ... ..1 (b) Retaining Plate....1 (a) 12 Socket Head Cap Screw 1/4-20 UNC x 1/2" .9 (a) 0-14 13 Clapper Hinge Pin..1 (a) 14 Reset Knob ......1 (c)or(d) / 15 Reset Spring .....1 (c) 15 16 Reset Bushing ....1 (c) / 17 Reset Bushing 16 O-Ring.. .........1 (b),(c)or(e) 10 1 1 18 Reset Plunger CLAPPER RESET O-Ring1 b or c ASSEMBLY 17 PLUNGER 19 Reset Plunger.....1 (c) j—1 PARTS 20 Reset Latch 18,21 Subassembly .....1 (c) 12 21 Dow Corning FS3452 Flourosilicone 19 Grease,1.5 g ... ..1 (b)or(c) 0 0 NR:Not Replaceable 20 CH:Common Hardware CD 0 \ REPLACEMENT PARTS ° NO. DESCRIPTION P/N / (a) Clapper Assembly Includes Items 9-13.. . 92-310-2-603 (b) Repair Parts Kit 2 0 Includes Items 7, 10,17, 18,21 . . . .. . 92-310-1-604 (c) Reset Plunger Parts Kit CD Includes Items 14-21 . . 92-310-1-405 l\ (d) Reset Knob, Item 14.. . 92-310-1-406 O O (e) Reset Plunger IO-Ring,Item 18 ..... . 92-310-1-407 4 / 1 7 00 3 5 o ® o 13 0 0 � o o ' 0 FIGURE 1 -PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVE 6 INCH(DN150)ASSEMBLY TFP1020 Page 4 of 20 Flange Drilling Specification Nominal Dimensions in Inches and(mm) Dim.A Nominal Bolt Circle Valve ANSI B16.11 ISO 7005-2 JIS B 2210 AS 2129 Diameter Size (Class 125) (PN16)2 (10K) (Table E) C"7 Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. City. o Dim. B A B N A B N A B N A B N ���Bolt Hole 4 in. 7.50 0.75 87.09 0.75 86.89 0.59 8 7.00 0.71 8 Diameter (DN100) (190,5) (19,0) (180,0) (19,0) (175,0) (15,0) (178,0) (18,0) � 6 in. 9.50 0.88 9.45 0.91 9.45 0.75 9.25 0.87 Qty.N (DN150) (241,3) (22,2) 8 (240,0) (23,0) 8 (240,0) (19,0) 8 (235,0) (22,0) 8 Number of Bolt Holes 1. Drilling same as ANSI 316.5(Class 150)and ANSI 1316.42(Class 150). 2. Drilling same as BS 4504 Section 3.2(PN16)and DIN 2532(PN16). TABLE A SELECTION OF FLANGE DRILLING SPECIFICATIONS ifications are NPT threaded per ANSI Pre-trimmed valve assemblies also 4 in.(DN100)FxF....................77 lb(36 kg) Standard B1.20.1. Trim port connec- include the following equipment: 6 in.(DN150)GxG...................95 lb(44 kg) tions of valves having flanges drilled . Model BFV-300 butterfly valve 6 in. DN150 FxG..................108 lb 50 k to ISO are available either threaded ( ) ( g) per ISO 7-1 or NPT threaded per ANSI • Figure 577 grooved coupling 6 in.(DN150)FxF...................121 lb(56 kg) Standard 131.20.1. Valves with NPT . PS10-2 waterflow alarm switch threaded ports will readily accept the Air Supply trim arrangements shown in Parts 2 • PS40-2 low air pressure alarm switch Table B shows the system air pres- and 3 of Figures 3, 4, and 5. Order the above equipment sepa- sure requirements as a function of the ro- Model DPV-1 Valve assemblies are rately when ordering trim packages water supply pressure.The air(or stem shown in Figure 1.The Body and Hand- separately. is re pressure in the sprinkler system hole Cover are ductile iron.The Hand- is recommended to be automatically hole Cover Gasket is neoprene, and Note: When the system pressure is maintained by using one of the follow- hole greater than 175 psi(12,1 bar),provision ing pressure maintenance devices, as the Clapper Facing is EPDM. The Air/ shall be made to replace the standard appropriate: Water Seat Ring is brass, the Clapper order 300 psi(20,7 bar)Water Pressure . Model AMD-1 Air Maintenance is bronze or aluminum bronze,and both gauge with a separately ordered 600 the Clapper Retaining Plate and Latch psi(41,4 bar) Water Pressure Gauge. Device(pressure reducing type) are bronze.The Hinge Pin is aluminum • Model AMD-2 Air Maintenance bronze,and the fasteners for the Hand- Weights Device(compressor control type) hole Cover are carbon steel. The following are the nominal weights for Pre-Trimmed Valve Assemblies, • Model AMD-3 Nitrogen Maintenance Valve Trim Semi-Assembled Trim, and DPV-1 Device(high pressure reducing type) Installation dimensions are provided Valves without trim. in Figure 6, and Valve Trim and Pre- The Pressure Relief Valve provided with Trimmed Valve Assemblies are shown Pre-Trimmed DPV-1 Valve the valve trim is factory set to relieve in Figures 3, 4, and 5. Assemblies: at a pressure of approximately 45 psi (3,1 bar). If the normal system air pres- The valve trim,ordered separately or as 2-1/2 in.(DN65)GxG..............87 lb(40 kg) sure is less than or exceeds 40 psi(2,8 a pre-trimmed valve assembly, forms 3 in.(DN80)GxG.....................90 lb(42 kg) bar), then the pressure Relief Valve t be reset to relieve at a pressure approvals of the DPV-1 Valve and is 4 in.(DN100)GxG.................121 lb(56 kg) that is in accordance with the authority necessary for the proper operation of 4 in.(DN100)FxG..................135 lb(64 kg) having jurisdiction. the DPV-1 Valve. 4 in.(DN100)FxF..................145 lb(69 kg) Quick Opening Device Trim packages or pre-trimmed valve The Model DPV-1 Dry Pipe Valve may assemblies include the following 6 in.(DN150)GxG.................175 lb(81 kg) optionally be equipped with an elec- equipment: 6 in.(DN150)FxG..................195 lb(90 kg) tronic or mechanical dry pipe valve • Water Supply Pressure Gauge accelerator. Select the VIZOR Elec- 6 in.(DN150)FxF...................208 lb(96 kg) tronic Dry Pipe Valve Accelerator • System Air Pressure Gauge Standard Galvanized (4 and 6 in. sizes only) described in • Air Supply Connections Semi-Assembled DPV-1 Trim: Technical Data Sheet TFP1105 or the Model ACC-1 Mechanical Dry Pipe • Main Drain Valve 2-1/2 in.(DN65)........................23 lb(11 kg) Valve Accelerator (2-1/2 through 6 in. • Low Body Drain Valve 3 in.(DN80)..............................23 lb(11 kg) sizes) described in Technical Data • Alarm Test Valve 4 in.(DN100)............................30 lb(14 kg) Sheet TFP1112. • Automatic Drain Valve 6 in. DN150 30 lb 14 k The VIZOR or the ACC-1 is used to ( ) ( g) reduce the time to valve actuation fol- • Drip Funnel DPV-1 Valve(Without Trim): lowing the operation of one or more • Connections For Optional Quick 2-1/2 in.(DN65)GxG...............37 lb(17 kg) automatic sprinklers. In some cases the use of a quick opening device Opening Device(Accelerator) 3 in.(DN80)GxG......................38 Ib(18 kg) such as the VIZOR or the ACC-1 may 4 in.(DN100)GxG...................57 lb(26 kg) be required to meet the requirements of the National Fire Protection Association 4 in.(DN100)FxG....................67 1b(31 kg) to meet water delivery times. TFP1020 Page 5 of 20 Maximum System Air FLOW RATE IN LITRES PER MINUTE(LPM) Water Supply Pressure (1 GPM=3.785 LPM) Pressure Range 500 700 1000 2000 3000 5000 10000 psi psi 9.0 � 0,60 20 10 a 7.0 0,50 60 15-23 = 80 20-28 0,40 z 5.0 100 25-33 Lu 4.0 0 0,30 Z� 145 36-43 O 3'0 Q 0,20 m 165 40-48 � 185 45-53 a 2.0 O Oa Q 205 50-58 0 ^� 0,10 tr m Lo 225 55-63 Z =�O� Q 0,08 LLJ°' 250 1 60-68 a 1.0 V� O= D o TABLE B z G� 0,06 co o 2 D C 0,05 w n SYSTEM AIR PRESSURE a 0.7 N = � REQUIREMENTS � ^� (0 0,04 a a p 0.5 ti z w 0,03 Operation r[ 0.4 0 0 0.3 0,02 Z The TYCO Model DPV-1 Dry Pipe Valve a is a differential type valve that utilizes a a 0.2 substantially lower system(air or nitro- Q gen) pressure than the supply (water) 0,01 pressure, to maintain the set position o shown in Figure 2A. The differential Z 0.1 nature of the DPV-1 is based on the 100 200 300 500 700 1000 2000 3000 area difference between the air seat FLOW RATE IN GALLONS PER MINUTE(GPM) and the water seat in combination with The approximate friction losses,based on the Hazen and Williams formula and expressed in equivalent length of the ratio of the radial difference from Schedule 40 pipe with C=100 and flowing at typical flow rates,are as follows: the Hinge Pin to the center of the Water 2-1/2 in.valve at 250 GPM flow=2.2 ft 4 in.valve at 600 GPM flow=8.9 ft Seat and the Hinge Pin to the center of 3 in.valve at 350 GPM flow=4.9 ft 6 in.valve at 1500 GPM flow=22.0 ft the Air Seat.The difference is such that GRAPH A 1 psi (0,07 bar) of system air pressure MODEL DPV-1 DRY PIPE VALVES can hold approximately 5.5 psi (0,38 1 NOMINAL PRESSURE LOSS VS. FLOW bar)of water supply pressure. Table B establishes the minimum sure of 100 psi (6,9 bar). It is for this After a valve actuation and upon sub- required system air pressure that reason that the plunger of the Auto- sequent closing of a system main includes a safety factor to help prevent matic Drain Valve must be depressed control valve to stop water flow, the false operations that occur due to water during several of the resetting steps, Clapper Assembly will latch open as supply fluctuations. as well as during inspections, making shown in Figure 3D. Latching open of certain that the Automatic Drain Valve the DPV-1 will permit complete drain- The Intermediate Chamber of the is open. ing of the system (including any loose DPV-1 is formed by the area between scale)through the main drain port. the Air Seat and Water Seat as shown in When one or more automatic sprin- Figure 213. The Intermediate Chamber klers operate in response to a fire, During the valve resetting procedure normally remains at atmospheric pres- air pressure within the system piping and after the system is completely sure through the Alarm Port connection is relieved through the open sprin- drained,the external reset knob can be and the valve trim to the normally open klers. When the air pressure is suf- easily depressed to externally unlatch Automatic Drain Valve (Fig. 3, 4, or ficiently reduced, the water pressure the Clapper Assembly, as shown 5). Having the Intermediate Chamber, overcomes the differential holding in Figure 2E. As such, the Clapper Figure 26, open to atmosphere is criti- the Clapper Assembly closed and the Assembly is returned to its normal set cal to the DPV-1 Valve remaining set, Clapper Assembly swings clear of the position to facilitate setting of the dry otherwise the full resulting pressure of water seat, as shown in Figure 2C, pipe sprinkler system,without having to the system air pressure on top of the This action permits water flow into the remove the Handhole Cover. Clapper Assembly cannot be realized. system piping and subsequently to be discharged from any open sprinklers. For example, and assuming a water Also,with the Clapper Assembly open, supply pressure of 100 psi (6,9 bar), if the intermediate chamber is pressur- the system air pressure is 25 psi (1,7 ized and water flows through the alarm bar) and there was 15 psi (1,0 bar) port (Ref. Figure 26) at the rear of the pressure trapped in the Intermediate DPV-1 Valve to actuate system water Chamber,the resulting pressure across flow alarms. The flow from the alarm the top of the Clapper would only be 10 port is also sufficient to close the oth- psi (0,7 bar). This pressure would be erwise normally open Automatic Drain insufficient to hold the Clapper Assem- Valve in the valve trim. bly closed against a water supply pres- TFP1O2O Page 6 of 20 Installation be equipped with a Dry Pipe Valve however, it must be reset to relieve Accelerator, refer to the Technical at a pressure which is in accordance General Instructions Data Sheet TFP1105 for the VIZOR with the requirements of the author- Proper operation of the Model DPV-1 Electronic Dry Pipe Valve Accel- ity having jurisdiction. Dry Pipe Valve depends upon its trim erator or TFP1112 for the Model To reset the Pressure Relief Valve, being installed in accordance with the ACC-1 Mechanical Dry Pipe Valve first loosen the jam nut and then instructions given in this Technical Data Accelerator. adjust the cap accordingly — Sheet. Failure to follow the appropriate • Care must be taken to make sure that clockwise for a higher pressure trim diagram may prevent the DPV-1 check valves,strainers,globe valves, setting or counter-clockwise for a Valve from functioning properly, as etc.are installed with the flow arrows lower pressure setting.After veri- well as void listings,approvals,and the in the proper direction. fying the desired pressure setting, manufacturer warranties. tighten the jam nut. • Drain tubing to the drip funnel must . Installation of an Air Maintenance Failure to latch open the Clapper be installed with smooth bends that Device,Installation described in the MaintTechnienance prior to a system hydro- will not restrict flow. cal Data Section, is recommended. static test may result in damage to the . The main drain and drip funnel drain Clapper Assembly. may be interconnected provided a • An Inspector's Test Connection as The DPV-1 Valve must be installed in a check valve is located at least 12 in. required By NFPA 13 must be pro- readily visible and accessible location. (300 mm)below the drip funnel.The vided on the system piping at the Low Body Drain Valve(Figure 3,4,or most remote location from the Model The DPV-1 Valve and associated trim DPV-1 Valve. must be maintained at a minimum tem- 5) may be piped so as to discharge must ure of 40°F maintained at into the Drip Funnel or to a separate Conduit and electrical connections peradrain. are to be made in accordance with Heat tracing of the DPV-1 Valve or its Suitable provision must be made the requirements of the author- associated trim is not permitted. Heat for disposal of drain water. Drainage ity having jurisdiction and/or the tracing can result in the formation of water must be directed such that it National Electric Code. hardened mineral deposits that are will not cause accidental damage to Before a system hydrostatic test is capable of preventing proper operation. property or danger to persons. performed in accordance with NFPA The Model DPV-1 Dry Pipe Valve is to 13 system acceptance test require- be installed in accordance with the fol- Unused pressure alarm switch and/ ments, the Clapper Assembly is to lowing criteria: or water motor alarm connections be manually latched open (Ref. Fig- must be plugged. ure 2D); the Automatic Drain Valve • All nipples,fittings,and devices must The Pressure Relief Valve provided (Figure 3,4,or 5)is to be temporarily be clean and free of scale and burrs with the Valve Trim is factory set to replaced with a 1/2 in. NPT plug,the before installation. Use pipe thread relieve at a pressure of approximately 3/32 in. Vent Fitting (Item 13, Figure sealant sparingly on male pipe 45 psi (3,1 bar), which can typically 3; Item 15, Figure 4; or Item 15, Fig- threads only. be used for a maximum normal sys- ure 5) is to be temporarily replaced • The DPV-1 Valve must be trimmed tem air pressure of 40 psi (2,8 bar). with a 1/4 in. NPT plug, and the in accordance with Figures 3, 4, or The Pressure Relief Valve may be Handhole Cover Bolts are to be tight- 5, as applicable. If the DPV-1 is to reset to a lower or higher pressure; ened using a cross-draw sequence. TFP1O2O Page 7 of 20 Valve Setting Step 5.As necessary,replace all sprin- to the Care and Maintenance section klers that have operated. Replacement under Automatic Drain Valve Inspection Procedure sprinklers must be of the same type to determine/correct the cause of the and temperature rating as those which leakage problem. Steps 1 through 11 are to be performed have operated. Step 10. Partially open the Main when initially setting the Model DPV-1 Control Valve. Slowly close the Main Dry Pipe Valve;after an operational test MUM Drain Valve as soon as water dis- of the fire protection system; or, after In order to prevent the possibility of charges from the drain connection. system operation due to a fire. a subsequent operation of an over- Depress the plunger on the Automatic NOTES:If the DPV-1 is equipped with heated solder type sprinkler,any solder Drain Valve to make sure that it is open a Dry Pipe Valve Accelerator, refer to type sprinklers which were possibly and that there is no water discharging. its resetting instructions before reset- exposed to a temperature greater than The absence of water discharging from ting the DPV-1.Refer to TFP1105 for the their maximum rated ambient must be the Automatic Drain Valve is an indica- VIZOR or TFP1112 for the ACC-1. replaced. tion of a properly set water seat within Based on the instructions provided, Step 6. Push down on the Reset Knob the DPV-1 Valve. If water is discharg- reset the Accelerator at the appropriate (Figure 2E)to allow the Clapper Assem- ing, refer to the Care and Maintenance time during the resetting of the DPV-1. bly to re-seat. section under the Automatic Drain Step 7. Pressurize the system with air Valve Inspection to determine/correct Unless otherwise noted,refer to Figure 3, 4, or 5 to identify functional trim (or nitrogen) to 10 psi (0,7 bar), and the cause of the leakage problem. components. then individually open all auxiliary drain If there are no leaks,the DPV-1 Valve is valves in the system piping to drain ready to be placed in service and the Step 1. Close the Main Control Valve, any remaining water in trapped sec- Main Control Valve must then be fully and close the Air Supply Control Valve. tions. Close each drain valve as soon opened. If the DPV-1 is equipped with a Dry as water ceases to discharge. Note: After setting a fire protection Pipe Valve Accelerator, remove the Dry Pipe Valve Accelerator from service in Also partially open the Low Body Drain system, notify the proper authorities accordance with its Technical Data Valve to assure that the riser is com- and advise those responsible for moni- S heet(Refer to TFP1105 for the VIZOR pletely drained. Close the Low Body toring proprietary and/or central station or TFP1112 for the ACC-1). Drain Valve as soon as water ceases alarms. Step 2.Open the Main Drain Valve and to discharge. Step 11. Once a week after a valve is all auxiliary drains in the system.Close Step 8. Refer to Table B and then reset following an operational test or the auxiliary drain valves after water restore the system to the normal system operation,the Low Body Drain ceases to discharge. Leave the Main system air pressure as necessary to Valve (and any low point drain valves) Drain Valve open. hold the DPV-1 Valve closed. should be partially opened (and then Step 9. Depress the plunger on the subsequently closed) to relieve drain- Step Depress the plunger the Automatic Drain Valve to make sure back water. Continue this procedure drain- Automatic tic Drain Valve to verify that it is until drain-back water is no longer it is open and that there is no air open and that the DPV-1 Valve is com-pletely drained. discharging. present. Step 4. Open the Optional Alarm The absence of air discharging from Control Valve, as applicable, if it was the Automatic Drain Valve is an indica- closed to silence local alarms. tion of a properly set air seat within the DPV-1 Valve. If air is discharging, refer TFP1020 Page 8 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM itCLAPPER CLAPPER 1" NPT ASSEMBLY ASSEMBLY AIR SUPPLY IN SET FULLY OPEN \ PORT POSITION CLAPPER LATCH PIVOTS TO ALLOW 1WATERT "o CLAPPER ASSEMBLY L ° SUPPLY �, TO FULLY OPEN PR ESSURE -T-T- 3/4" NPT ALARM - - &ALARM i�Y PORT OPEN TO TEST PORT ATMOSPHERE VALARM PORT WATERFLOW CLAPPER TO ALARM ASSEMBLY FROM FROM WATER SUPPLY AIR WATER SUPPLY SEAT FIGURE 2A FIGURE 2C SET POSITION WATER OPERATED POSITION SEAT I � ALARM \ PORT DRAIN FROM DRAIN FROM SYSTEM SYSTEM VALVE INTERMEDIATE COMPLETE WATERWAY CHAMBER PUSH HERE It FIGURE 2B TO RESET SET POSITION VALVE INTERMEDIATE RESET CLAPPER CHAMBER KNOB ASSEMBLY - - LATCHED RESET OPEN ASSEMBLY CLAPPER _ LATCH o PIVOTS TO r o CLAPPER UNLATCH ' LATCH CLAPPER ASSEMBLY MAIN DRAIN PORT: 3/4" NPT 1-1/4" NPT`(2-1/2 INCH CLAPPER LOW BODY &3 INCH VALVES) ASSEMBLY DRAIN 2" NPT(4 INCH VALVE) RESEATED PORT WATER SUPPLY DN40 FOR VALVES WITH WATER SUPPLY SHUT OFF ISO THREADED PORTS SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVES 2-112, 3,AND 4 INCH(DN65, DN80,AND DN100) SET AND OPEN POSITIONS TFP1020 Page 9 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM CLAPPER t ASSEMBLY t FULLY OPEN 1" NPT CLAPPER LATCH AIR SUPPLY PIVOTS TO ALLOW PORT CLAPPER ASSEMBLY TO FULLY OPEN 3/4" NPT ALARM PORT OPEN TO ° CLAPPER ATMOSPHERE ASSEMBLY f, IN SET POSITION 1/2" NPT WATER SUPPLY m PRESSURE /— &ALARM TEST PORT ALARM PORT WATERFLOW CLAPPER TO ALARM ASSEMBLY AIR FROM SEAT FROM WATER SUPPLY WATER SUPPLY FIGURE 2A ALARM FIGURE 2C SET POSITION WATER PORT OPERATED POSITION SEAT m I DRAIN FROM DRAIN FROM SYSTEM SYSTEM INTERMEDIATE VALVE COMPLETE CHAMBER WATERWAYIt PUSH HERE FIGURE 2B SET POSITION TO RESET INTERMEDIATE VALVE CLAPPER CHAMBER RESET ASSEMBLY KNOB LATCHED OPEN - - RESET ASSEMBLY 3/4" NPT CLAPPER LOW BODY ° LATCH ` ° DRAIN PORT PIVOTS TO UNLATCH ' �- CLAPPER i i ASSEMBLY 2" NPT CLAPPER MAIN DRAIN LATCH PORT CLAPPER ASSEMBLY RESEATED WATER SUPPLY WATER SUPPLY SHUT OFF SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVES 6INCH(DN150) SET AND OPEN POSITIONS TFP1020 Page 10 of 20 NOTES: 1. SEE FIGURE 3 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. / SWITCH SYSTEM AIR SUPPLY 1 INCH NPT SYSTEM CONTROL VALVE CONNECTION AIR SUPPLY / (NORMALLY FOR LOCAL PRESSURE OPEN) SPRINKLER GAUGE �I 2-1/2 INCH(DN65) ��/A WATERFLOW 1/2 INCH NPT / or INCH(DN80) PRESSURE CONNECTION MODEL DPV-1 ALARM FOR SYSTEM DRY PIPE VALVE / SWITCH AIR SUPPLY (GxG ONLY) GROOVED MAIN COUPLING TEST VALVE e® DRAIN VALVE (NORMALLY ® (NORMALLY 1/2 INCH NPT CLOSED) CLOSED) CONNECTION SYSTEM 3/4 IN NPT \ SYSTEM FOR OPTIONAL WATER CONNECTION SHUT-OFF SUPPLY 1-1/4 INCH NPT ACCELERATOR PRESSURE TO DRAIN VALVE CONNECTION GAUGE LOW BODY (NORMALLY TO DRAIN AUTOMATIC DRAIN VALVE OPEN) DRAIN VALVE (NORMALLY 1-1/4 INCH NPT CLOSED) CONNECTION DRIP TO DRAIN FUNNEL FIGURE 3-PART 1 OF 3 2-112 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY AIR SUPPLY 1/2 INCH NPT 1/2 INCH NPT NOTES: CONTROL VALVE CONNECTION CONNECTION 1. INSTALL TRIM ASSEMBLIES IN (NORMALLY OPEN) FOR OPTIONAL FOR OPTIONAL ALPHABETICAL ORDER. ACCELERATOR AIR PRESSURE AUTOMATIC SWITCH 2. SEE FIGURE 2 FOR VALVE PORT 1/2 INCH NPT I DRAIN VALVE IDENTIFICATION. CONNECTION 3. ROUTE 1/4"TUBING TO DRIP FOR SYSTEM AIR SUPPLY H FUNNEL. \e = SYSTEM AIR SUPPLY MAIN 1/2 INCH NPT G D PRESSURE GAUGE A DRAIN VALVE CONNECTION (NORMALLY FOR WATERFLOW \ E \ CLOSED) PRESSURE ALARM SWITCH 1-1/4 INCH NPT DRIP CONNECTION FUNNEL TO DRAIN 1-1/4 INCH NPT \ CONNECTION 2-1/2 INCH(DN65) TO DRAIN 1 INCH NPT C or 3 INCH(DN80) CONNECTION MODEL DPV-1 FOR LOCAL DRY PIPE VALVE SPRINKLER (GxG ONLY) ALARM / F B/ LOW BODY TEST VALVE � DRAIN VALVE (NORMALLY SYSTEM (NORMALLY CLOSED) WATER SUPPLY 3/4 INCH NPT CLOSED) PRESSURE CONNECTION GAUGE TO DRAIN FIGURE 3-PART 2 OF 3 2-112 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 11 of 20 NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N 1 250 psi/1750 kPa 13 3/32"Vent 28 1"x 1"x 1/2" Air Pressure Fitting .. .. .. ... ..1 92-032-1-002 Reducing Tee ... ..1 CH Gauge.. .. .. ... ..1 92-343-1-012 14 1/4"Tube, 29 Not Used 2 300 psi/2000 kPa 18" Long....... ..1 CH PIPE NIPPLES: Water Pressure 15 1/4" Plug....... ..2 CH 30 1/4"x 3" ....... ..2 CH Gauge.. .. .. ... ..1 92-343-1-005 16 1/2" Plug....... ..2 CH 31 1/2"x Close .... ..4 CH 3 1/4"Gauge Test 17 1" Plug . .........1 CH 32 1/2"x 1-1/2".... ..8 CH Valve. .. .. .. ... ..2 46-005-1-002 18 1/2" Union. .......1 CH 33 1/2"x 2" ....... ..1 CH 4 Model AD-1 19 1/2"x 1/4" Reducing 34 1/2"x 4-1/2".... ..1 CH Automatic Bushing .........1 CH 35 1/2"x 6" ....... ..1 CH Drain Valve .. ... ..1 52-793-2-004 20 1/2"90'Elbow....3 CH 36 3/4"x Close .... ..1 CH 5 1/4" Pressure 21 3/4"90'Elbow....1 CH 37 3/4"x 1-1/2".... ..1 CH Relief Valve.. ... ..1 92-343-1-020 22 1-1/4"90'Elbow...1 CH 38 3/4"x 2-1/2".... ..1 CH 6 1/2" Ball Valve .. ..2 46-050-1-004 23 1/2"Cross........2 CH 39 1"x Close...... ..1 CH 7 3/4"Angle Valve. ..1 46-048-1-005 24 1/2"x 1/2"x 1/4" 40 1-1/4"x Close .. ..1 CH 8 1-1/4"Angle Valve .1 46-048-1-007 Reducing Tee .....1 CH 41 1-1/4"x 4"...... ..1 CH 9 1/2"Swing 25 1/2"Tee .........1 CH COMPONENTS INCLUDED ONLY IN Check Valve .... ..2 46-049-1-004 26 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 10 Drip Funnel Reducing Tee .....2 CH Connector... ... ..1 92-211-1-005 27 1/2"x 1/2"x 3/4" 42 Model BFV-300 11 Drip Funnel Reducing Tee .....1 CH Butterfly Valve, Bracket. .... ... ..1 92-211-1-003 2-1/2"(DN65).....1 59300GO25W 12 Drip Funnel.. ... ..1 92-343-1-007 3"(DN80) ........1 59300GO30W 45 43 Figure 577 Coupling, 2-1/2"(DN65).....1 57725ACP \/ 16 3"(DN80) ...... ..1 57730ACP 44 Waterflow Pressure 20 1 Alarm Switch, Model PS10-2... ..1 25710 9 19 45 Low Air Pressure 32 30 Alarm Switch, 5 32 6 32 23 Model PS40-2... ..1 25730 32 24 20 17 32 15 ® 34 39 3 44 33 28 2-1/2 INCH(DN65) g 16 4 or 3 INCH(DN80) MODEL DPV-1 25 31 27 DRY PIPE VALVE (GxG ONLY) 31 LOCATION 32 23 FOR OPTIONAL 10 36 41 8 18 ELECTRICALLY SUPERVISED 32 N.O.ALARM 20 1 22 31 40 CONTROL 11 VALVE 26 13 12 37 NOTES: 1 (GREEN 14 43 1. SEE FIGURE 2 FOR VALVE TINS 21 PORT IDENTIFICATION. 38 7 42 2. ROUTE 114"TUBING,ITEM 14, 31 TO DRIP FUNNEL,ITEM 12. 6 3. ALL FITTINGS AND NIPPLES 32 35 o ARE GALVANIZED. 26 2 4. CH:COMMON HARDWARE 30 5. ITEMS 42-45 INCLUDED 3 ONLY IN PRE-TRIMMED VALVE ASSEMBLIES AS APPLICABLE;OTHERWISE SEPARATELY ORDERED. FIGURE 3-PART 3 OF 3 2-1 12 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 12 of 20 1. SEE FIGURE 4 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM / AIR SUPPLY 1/2 INCH NPT SYSTEM 4 INCH(DN100) CONTROL VALVE CONNECTION AIR SUPPLY MODEL VALVE (NORMALLY \/ ® FOR SYSTEM PRESSURE DRY PIPE VALVE OPEN) AIR SUPPLY GAUGE (FxG SHOWN) 3/4 INCH NPT J 1 INCH NPT CONNECTION FLANGE ADAPTER FOR WATER CONNECTION OR GROOVED FOR LOCAL COUPLING MOTOR ALARM SPRINKLER MAIN WATERFLOW C�3/4 INCH NPT � � DRAIN VALVE o PRESSURE CONNECTION (NORMALLY ALARM TO DRAIN / CLOSED) 1/2 INCH NPT SWITCH CONNECTION ALARM / FOR OPTIONAL TEST VALVE \ SYSTEM 2 INCH NPT ACCELERATOR (NORMALLY LOW BODY CONNECTION CLOSED) DRAIN VALVE SYSTEM SHUT-OFF TO DRAIN AUTOMATIC WATER VALVE (NORMALLY SUPPLY (NORMALLY DRAIN VALVE CLOSED) PRESSURE OPEN) 1-1/4 INCH NPT GAUGE CONNECTION DRIP TO DRAIN FUNNEL FIGURE 4-PART 1 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT AIR SUPPLY CONNECTION CONTROL VALVE FOR OPTIONAL (NORMALLY ACCELERATOR OPEN) 1/2 INCH NPT MAIN CONNECTION SYSTEM DRAIN VALVE 0 1/2 INCH NPT AUTOMATIC AIR SUPPLY NORMALLY CONNECTION DRAIN VALVE FOR OPTIONAL PRESSURE AIR PRESSURE CLOSED) FOR WATERFLOW \ SWITCH GAUGE SLOPE PRESSURE ALARM DOWN SWITCH \ D I 3/4 INCH NPT CONNECTION FOR WATER A MOTOR ALARM � \ � 1/2 INCH NPT �/ 2 INCH NPT CONNECTION CONNECTION FOR SYSTEM ~ TO DRAIN � I AIR SUPPLY C 0 4 INCH(DN100) ALARM �' �o_ — C) MODEL DPV-1 TEST VALVE / DRY PIPE VALVE (NORMALLY (FxG SHOWN) CLOSED) 3/4 1 INCH NPT NOTES: B CONNECTION 1. INSTALL TRIM ASSEMBLIES IN SYSTEM INCH NPT FOR LOCAL ALPHABETICAL ORDER. ONNECTON CI WATER SUPPLY SPRINKLER PRESSURE TO DRAIN 2. SEE FIGURE 2 FOR VALVE PORT GAUGE LOW BODY IDENTIFICATION. DRIP DRAIN VALVE 3. ROUTE 1/4"TUBING TO DRIP FUNNEL. FUNNEL 1-1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE TO DRAIN SUFFICIENT LOW BODY DRAINAGE. FIGURE 4-PART 2 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 13 of 20 l NOTES: 47 16 48 1. SEE FIGURE 2 FOR VALVE 28 18 PORT IDENTIFICATION. 5 6 2. ROUTE TUBING, ITEM 16, FUNNEL, 0 15 27 TO DRIP FUNNEL,ITEM 14. 34 (GREEN 3. SLOPE 3/4"ANGLE VALVE, 9 29 y TINT) 18 12 ITEM 9,DOWN TOWARD SLOPE 34 14 BACK OF VALVE TO DOWN ® 34 26 34 FACILITATE SUFFICIENT 8 LOW BODY DRAINAGE. 19 34 27 = 4. ALL FITTINGS AND NIPPLES 36 ARE GALVANIZED. LOCATION FOR OPTIONAL 30 21 1 5. CH:COMMON HARDWARE ELECTRICALLY r 32 17 13 6. ITEMS 45-48 INCLUDED SUPERVISED 3 ONLY IN PRE-TRIMMED N.O.ALARM 41 30 VALVE ASSEMBLIES AS CONTROL 39 40 APPLICABLE;OTHERWISE VALVE 10 SEPARATELY ORDERED. 39 i' 23 30 40 4 INCH(DN100) 24 34 84 43 MODEL DPV-1 1 DRY PIPE VALVE 33 42 31 I (FxG SHOWN) 25 7 9 20 CQ CD 0 33 38 � 46 37 CD �(D 2 11 44 NO. DESCRIPTION QTY P/N 22 1 250 psi/1750 kPa 28 3 45 Air Pressure 35 Gauge.. .........1 92-343-1-012 32 17 2 300 psi/2000 kPa Water Pressure Gauge.. .........1 92-343-1-005 3 1/4"Gauge Test NO. DESCRIPTION QTY P/N Valve. .. .........2 46-005-1-002 4 1/4" Pressure 21 1/2"x 1/4" Reducing Relief Valve.......1 92-343-1-020 Bushing ....... ..1 CH 5 1/2"Angle Valve...1 46-048-1-004 22 1/2" Union...... ..1 CH NO. DESCRIPTION QTY P/N 6 Model AD-1 23 3/4" Union...... . . 1 CH 41 3/4"x 2" .. .. ... ..1 CH Automatic 24 1/2"90'Elbow.. .. 1 CH 42 3/4"x 3" .. .. ... ..1 CH Drain Valve .. ... ..1 52-793-2-004 25 1/2"45'Elbow....1 CH 43 1"x 4".. .. .. ... ..1 CH 7 1/2" Ball Valve .. ..1 46-050-1-004 26 1/2"Cross........1 CH 44 2"x 4-1/2". .. ... ..1 CH 8 1/2"Swing 27 1/2"Tee .........2 CH COMPONENTS INCLUDED ONLY IN Check Valve . ... ..1 46-049-1-004 28 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 9 3/4"Angle Valve. ..1 46-048-1-005 Reducing Tee .....2 CH 10 3/4"Swing 29 1/2"x 1/2"x 1/4" 45 Model BFV-300 Butterfly Check Valve .... ..1 46-049-1-005 Reducing Tee .....1 CH Valve,4"(DN100)..1 59300GO40W 11 2"Angle Valve .. ..1 46-048-1-009 30 3/4"x 1/2"x 3/4" 46 Butterfy Valve 12 Drip Funnel Reducing Tee .....3 CH Assembly Component: Connector... ... ..1 92-211-1-005 31 1"x 1"x 1/2" GxG DPV-1 Valves, 13 Drip Funnel Reducing Tee ... ..1 CH Figure 577 Coupling, Bracket. .........1 92-211-1-003 PIPE NIPPLES: 4"(DN100) .......1 57740ACP 14 Drip Funnel.......1 92-343-1-007 32 1/4"x 3" ....... ..2 CH FxF,FxG DPV-1 Valves, 15 3/32"Vent 33 1/2"x Close .... ..2 CH Figure 71 Flange Adapter, Fitting .. .........1 92-032-1-002 34 1/2"x 1-1/2".... ..7 CH 4"(DN100) .......1 7140S 16 1/4"Tube, 35 1/2"x 2" ....... ..1 CH 47 Waterflow Pressure 24" Long.........1 CH 36 1/2"x 2-1/2".... ..1 CH Alarm Switch, 17 1/4" Plug.........2 CH 37 1/2"x 3" .........1 CH Model PS10-2.....1 25710 18 1/2" Plug.........2 CH 38 1/2"x 3-1/2"......1 CH 48 Low Air Pressure 19 3/4" Plug.........1 CH 39 3/4"x Close ......2 CH Alarm Switch, 20 1" Plug . .........1 CH 40 3/4"x 1-1/2"......2 CH Model PS40-2.....1 25730 FIGURE 4-PART 3 OF 3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 14 of 20 NOTES: 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM AIR SUPPLY SYSTEM CONTROL VALVE AIR SUPPLY (NORMALLY PRESSURE OPEN) 1/2 INCH NPT GAUGE CONNECTION SYSTEM LOW BODY FOR SYSTEM / WATER DRAIN VALVE AIR SUPPLY SUPPLY (NORMALLY PRESSURE CLOSED) 1 INCH NPT GAUGE CONNECTION ®AUTOMATIC FOR LOCAL GROOVED DRAIN VALVE SPRINKLER COUPLING OR FLANGE ° 1/2 INCH NPT DRIP FUNNEL ADAPTER CONNECTION e FOR OPTIONAL MAIN / ® ACCELERATOR DRAIN VALVE ALARM (NORMALLY 2 INCH NPT TEST VALVE 1-1/4 INCH NPT CLOSED) CONNECTION SYSTEM (NORMALLY WATERFLOW CONNECTION 6 INCH(DN150) SHUT-OFF CLOSED) 3/4 INCH NPT PRESSURE TO DRAIN MODEL DPV-1 VALVE CONNECTION ALARM TO DRAIN DRY PIPE VALVE (NORMALLY FOR WATER SWITCH (GxG SHOWN) OPEN) MOTOR ALARM FIGURE 5-PART 1 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT 1/2 INCH NPT NOTES: B CONNECTION CONNECTION 4. SLOPE 3/4"ANGLE VALVE AND ��' d FOR OPTIONAL FOR SYSTEM 3/4"x 4-1/2" NIPPLE(OF ASSEMBLY B) O va SYSTEM AIR PRESSURE AIR SUPPLY INTO DRIP FUNNEL TO FACILITATE AIR SUPPLY SWITCH SUFFICIENT LOW BODY DRAINAGE. PRESSURE AIR SUPPLY DRIP GAUGE \, CONTROL VALVE LOW BODY 112 INCH NPT FUNNEL— (NORMALLY DRAIN VALVE CONNECTION SLOPE 1 INCH NPT OPEN) (NORMALLY FOR OPTIONAL TO FIT CONNECTION CLOSED) ACCELERATOR 1/2 INCH NPT FOR LOCAL CONNECTION SPRINKLER A o o AUTOMATIC FOR WATERFLOW 0 o DRAIN VALVE PRESSURE ALARM (7) SWITCH 0 0 MAIN o o B 3/4 INCH NPT CONNECTION DRAIN VALVE FOR WATER (NORMALLY I MOTOR ALARM CLOSED) D 2 INCH NPT CONNECTION 6 INCH(DN150) / TO DRAIN MODEL DPV-1 DRIP i D(FxF SHOWN)RY PIPE E FUNNEL (; NOTES: 1. INSTALL TRIM ASSEMBLIES IN ALPHABETICAL ORDER. / ALARM 2. SEE FIGURE 2 FOR VALVE PORT 1-1/4 INCH NPT SYSTEM TEST VALVE IDENTIFICATION. CONNECTION WATER SUPPLY (NORMALLY 3. ROUTE 1/4"TUBING TO DRIP TO DRAIN PRESSURE CLOSED) FUNNEL. GAUGE FIGURE 5-PART 2 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP102O Page 15 of 20 9 BACK OF 4 NOTES: 1. SEE FIGURE 2 FOR VALVE 4. ALL FITTINGS AND NIPPLES (( VALVE 29 PORT IDENTIFICATION. ARE GALVANIZED. 42 \\ o 35 2. ROUTE 1/4"TUBING, ITEM 16, 5. CH:COMMON HARDWARE 5 TO DRIP FUNNEL, ITEM 14. 6. ITEMS 45-48 INCLUDED 14-- 18 3. SLOPE 3/4"ANGLE VALVE, ONLY IN PRE-TRIMMED SLOPE 48 ITEM 9,AND 3/4"x 4-1/2" VALVE ASSEMBLIES AS TO FIT 35 NIPPLE, ITEM 42, INTO APPLICABLE;OTHERWISE DRIP FUNNEL, ITEM 14,TO SEPARATELY ORDERED. 1 21 26 ~ 8 40 FACILITATE SUFFICIENT 15 LOW BODY DRAINAGE. (GREEN LOCATION 35 TINT) FOR OPTIONAL 3 9 85 18 �� ELECTRICALLY 30 27 SUPERVISED 17 33 35 42 6 16 47 N.O.ALARM 11 20 43 27 35 28 CONTROL 32 31 37 VALVE � 40 31 44 10 40 i 40 41 19 23 6 INCH(DN150) 1� 42 12 MODEL DPV-1 DRY PIPE VALVE 40 (GxG SHOWN) 31 13 35 24 NO. DESCRIPTION QTY P/N 39 14 38 1 250 psi/1750 kPa 22 7 34 Air Pressure 36 35 25 Gauge.. .........1 92-343-1-012 28 2 300 psi/2000 kPa 2 Water Pressure Gauge.. .........1 92-343-1-005 3 1/4"Gauge Test Valve. .. .. .. ... ..2 46-005-1-002 33 4 1/4" Pressure 46 3 Relief Valve..... ..1 92-343-1-020 17 NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve. ..1 46-048-1-004 45 35 1/2"x 1-1/2".... ..8 CH 6 Model AD-1 36 1/2"x 2" ....... ..1 CH Automatic 37 1/2"x 2-1/2".... ..1 CH Drain Valve .......1 52-793-2-004 ® 38 1/2"x 3" ....... ..1 CH 7 1/2" Ball Valve .. ..1 46-050-1-004 ® 39 1/2"x 6" ....... ..1 CH 8 1/2"Swing 40 3/4"x 1-1/2"......5 CH Check Valve ......1 46-049-1-004 p 41 3/4"x 2" .........1 CH 9 3/4"Angle Valve...1 46-048-1-005 42 3/4"x 4-1/2"......2 CH 10 3/4"Swing 43 1"x 4".. .........1 CH Check Valve . ... ..1 46-049-1-005 44 2"x 4-1/2"... ... ..1 CH 11 2"Angle Valve .. ..1 46-048-1-009 COMPONENTS INCLUDED ONLY IN 12 Drip Funnel Connector...... ..1 92-211-1-005 PRE-TRIMMED VALVE ASSEMBLIES: 13 Drip Funnel NO. DESCRIPTION QTY P/N 45 Model BFV-300 Butterfly Bracket. ....... ..1 92-211-1-003 25 1/2"45'Elbow.. ..1 CH Valve,6"(DN150)..1 59300GO60W 14 Drip Funnel..... ..1 92-343-1-007 26 1/2"Cross .......1 CH 46 Butterfy Valve 15 3/32"Vent 27 1/2"Tee .........2 CH Assembly Component: Fitting .. .........1 92-032-1-002 28 1/2"x 1/4"x 1/2" GxG DPV-1 Valves, 16 1/4"Tube, Reducing Tee .....2 CH Figure 577 Coupling, 24" Long....... ..1 CH 29 1/2"x 1/2"x 1/4" 6"(DN150) .......1 57760ACP 17 1/4" Plug....... ..2 CH Reducing Tee .....1 CH FxF,FxG DPV-1 Valves, 18 1/2" Plug....... ..2 CH 30 3/4"90'Elbow....1 CH Figure 71 Flange Adapter, 19 3/4" Plug....... ..1 CH 31 3/4"x 1/2"x 3/4" 6"(DN150) .......1 7160S 20 1" Plug . .... ... ..1 CH Reducing Tee .....3 CH 47 Waterflow Pressure 21 1/2"x 1/4" Reducing 32 1"x 1"x 1/2" Alarm Switch, Bushing .. . . . . . . . 1 CH Reducing Tee ... ..1 CH Model PS10-2.....1 25710 22 1/2" Union. . . . . . . . 1 CH PIPE NIPPLES: 48 Low Air Pressure 23 3/4" Union... ... .. 1 CH 33 1/4"x 3" .. .. ... ..2 CH Alarm Switch, 24 1/2"90'Elbow....1 CH 34 1/2"x Close . ... ..1 CH Model PS40-2... ..1 25730 FIGURE 5-PART 3 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 16 of 20 7-1/8" _ _ 8-3/8" 14-7/8" 9-1/4" (180 mm) (213 mm) (380 mm) (235 mm) 2-1/2&3 INCH 0 ® o (DN65&DN80) 20-7/16" VALVE ® (520 mm) 16-1/8" (409,6 mm) 2-1/2 or 3 INCH ° q VALVES ° P o 0 if _ 12" 9-5/8" _ 12" __ 14" (300 mm) (245 mm) (300 mm) (355 mm) 4 INCH O a o (DN100) VALVE ® 21-7/8" ® (555 mm) d� FxF: 18-3/16"(462 mm) O �qP FxG: 18-1/4"(464 mm) ® ac GxG:18-5/16"(465 mm) o O O 11-1/2" 11-3/8" 15" 14-3/4" _ (290 mm)�~(289 mm) (380 mm) (375 mm) 6INCH (DN 150) VALVE 0 P O 24-1/2" 0 (620 mm) d b 21-7/8" O (555,6 mm) O O O FIGURE 6-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, PRE-TRIMMED VALVE TFP1020 Page 17 of 20 6-3/4" 8" 14-7/8" 9-1/4" (170 mm) (200 mm) (380 mm) (235 mm) 2-1/2&3 INCH O vc 16-9/16" ® o (DN65&DN80) (420,7 mm) VALVE ® 12-1/4" (311, 2-1/2 orr IN 3 INCH VALVES o qP �I Y 6" (150 mm) _ 12" _ 6" 12" _ 14" _ (300 mm) (150 mm) (300 mm) (355 mm) 4 INCH D Q 17-1/4" O (DN100) qP (440 mm) VALVE ® ® FxF:13-5/8"(346,1 mm) FxG: 113 1/4" 49,3 mm) .pbQ GxG:13-3/4"(349,3 mm) �qP ® DQ O 2-1/2"(65 mm) 11-1/2" 7-1/4" 15" __ 14-3/4" (290 mm) (190 mm) �_— (380 mm) (375 mm) 6INCH (DN150) VALVE O D P 18-3/4" o (475 mm) ® 16" (406,4 mm) FxF,FxG, or GxG ° D Q o �P nQ o 4-1/2" (115 mm) FIGURE 6-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, VALVE AND SEMI-ASSEMBLED TRIM TFP1020 Page 18 of 20 Step 3. Verify that the DPV-1 Valve Care and has operated, as indicated by the flow Nominal Torque Maintenance of water into the system and that all Valve Sizes lb-ft waterflow alarms operate properly. in. (N•m) (DN) The following procedures and inspec- Step 4.Close the system Main Control tions should be performed as indicated, Valve. 2-1/2 30 in addition to any specific requirements (DN65) (41) Step 5. Reset the DPV-1 Valve in of the NFPA,and any impairment must accordance with the Valve Setting 3 30 be immediately corrected. Procedure. (DN80) (41) Before closing a fire protection system Note: It is recommended that the 4 30 main control valve for maintenance requirement of NFPA 25 to annually (DN100) (41) work on the fire protection system that inspect the inside of the valve be per- 6 55 it controls,permission to shut down the formed at this time and prior to reset- (DN150) (75) affected fire protection system must be ting the DPV-1 Valve. Refer to the obtained from the proper authorities Automatic Drain Valve Inspection sub- TABLE C and notify all personnel who may be HANDHOLE COVER BOLTS affected by action. section Steps 2 through 5 for ction of MAXIMUM TORQUE tions with regard to the inspection of The owner is responsible for the the Clapper Facing. inspection,testing,and maintenance of Quarterly Waterf low Alarm Test Gauge), and then after removing the their fire protection system and devices d roceure p Handhole Cover, perform the follow- in compliance with this document, as ing steps: well as with the applicable standards Testing of the system waterflow alarms of the National Fire Protection Associa- should be performed quarterly.To test Step 1. Make sure that the Seat Ring tion (e.g., NFPA 25), in addition to the the waterflow alarm, open the Alarm is clean and free of any nicks or signifi- standards of any authority having juris- Test Valve, which will allow a flow of cant scratches. diction. Contact the installing contrac- water to the Waterf low Pressure Alarm Step 2. Remove the Clapper Assem- tor or sprinkler manufacturer regarding Switch and/or Water Motor Alarm. bly from the valve by first pulling out any questions. Upon satisfactory completion of the the Hinge Pin. Automatic sprinkler systems are rec- test, close the Alarm Test Valve. Step 3. Disassemble the Clapper ommended to be inspected, tested, Water Pressure Inspection Facing Retainer from the Clapper and maintained by a qualified Inspec- The Water Pressure Gauge is to be so that the Clapper Facing can be tion Service in accordance with local inspected monthly (per NFPA 25) to removed and inspected. Make sure requirements and/or national codes. ensure that normal system water pres- that the Clapper Facing does not show sure is being maintained. signs of compression set,damage,etc. The operational test procedure and Clapper the lace waterflow pressure alarm test pro- Air Pressure Inspection Replace PP Facing if there is cedure will result in operation of the The Air Pressure Gauge is to be any signs of wear. associated alarms. Consequently, inspected monthly (per NFPA 25) to Step 4. Clean the Clapper Facing, notification must first be given to the ensure that normal system air pressure Clapper, and Clapper Facing Retainer, owner and the fire department, central is being maintained. and then reassemble the Clapper station,or other signal station to which Automatic Drain Valve Inspection Assembly. the alarms are connected. The Automatic Drain Valve should be Step 5.Reinstall the Clapper Assembly Annual Operation Test Procedure inspected monthly (per NFPA 25) by with its Hinge Pin. Note:Unless otherwise noted, refer to depressing the plunger and check- Figure 3, 4, or 5 to identify functional g in to ensure that the Automatic Drain Step 6. Install Handhole Cover: trim components. Valve is not discharging water and/or a. Align Handhole Cover Gasket and air. A discharge of water and/or air is Handhole Cover in proper orien- Proper operation of the DPV-1 Valve an indication that the air and/or water tation with valve body(Ref. Figure (i.e.,opening of the DPV-1 Valve during seats are leaking, which could subse- 1)and hold in place a fire condition) should be verified at quently cause a false operation should least once a year as follows: the intermediate chamber become b. Apply o Hex E It t rea s equiv- Step 1. If necessary, prevent water inadvertently pressurized. anent)to Hex Bolt threads Hand- from flowing beyond the riser by: If leakage is present, take the DPV-1 c. Insert Hex Bolts through Hand- • Close the Main Control Valve Valve out of service (i.e., close the hole Cover Gasket and le main control valve,open the main drain Cover, hand-tighten inttoo valve • Open the Main Drain Valve valve,close the air supply control valve, body • Open the Main Control Valve one turn remove the Dry Pipe Valve Accelerator d. Using crossdraw sequence to beyond the position at which water from service, as applicable, in accor- assure uniformity,wrench-tighten just begins to flow from the Main dance with its Technical Data Sheet Hex Bolts to appropriate torque Drain Valve (Refer to TFP1105 for the VIZOR or values(Ref.Table C) • Close the Main Drain Valve TFP1112 for the ACC-1), and open the e. Inspect to assure all Hex Bolts Inspector's Test Connection to relieve are securely tightened Step 2. Open the system Inspector's the system air pressure to 0 psig as Test Connection. indicated on the System Air Pressure TFP1020 Page 19 of 20 Limited Specify:6 in. DPV-1 Pre-Trimmed Valve Accessories Assembly, (specify) End Connection, Refer to Technical data Sheets describ- Warranty P/N (specify): ing the following accessories, as Flange x Flange...............52-310-3-060 applicable. For warranty terms and conditions,visit Flange x Groove...............52-310-3-460 Specify: Description, P/N (specify): www.tyco-fire.com. Groove x Groove..............52-310-3-960 Model PS10-2 Potter Electric Waterflow Pre-Trimmed DPV-1 Assemblies Pressure Alarm Switch ...............25710 Ordering without Butterfly Valve (Ref.Potter Electric Technical Data Sheet) Specify:4 in. DPV-1 Pre-Trimmed Valve Model PS40-2 Potter Electric Low Air Pressure Alarm Switch ...............25730 Procedure Assembly without Butterfly, (Specify) (Ref.Potter Electric Technical Data Sheet) End Connection, P/N (specify): Model WMA-1 Contact your local distributor for avail- Water Motor Alarm.............52-630-1-001 ability.When placing an order.indicate Flange x Flange...............52-310-4-440 (Ref.Technical Data Sheet TFP921) y p g Flange xGroove...............52-310-4- 40 the full product name and Part Number Model AMD-1 (P/N). Specify:6 in. DPV-1 Pre-Trimmed Valve Air Maintenance Device.........52-324-2-002 Assembly without Butterfly, (specify) (Ref.Technical Data Sheet TFP1221) Standard DPV-1 Dry Pipe Valve End Connection, P/N (specify) Model AMD-2 ( p y)� Air Maintenance Device.........52-326-2-001 ANSI standard outside diameter(O.D.) pipe size with grooved or ANSI drilled Flange x Flange...............52-310-4- 60 (Rod el AMDc31 Data Sheet TFP1231) Flange xGroove...............52-310-4-460 flange end connections and NPT Nitrogen Maintenance Device....52-328-2-001 threaded ports. Standard Galvanized (Ref.Technical Data Sheet TFP1241) Specify: (specify size) Model DPV-1 Semi-Assembled DPV-1 TrimNote: Valves with NPT threaded ports Replacement Valve Parts Dry Pipe Valve with(specify) End Con- are intended for use with the Standard Specify: (description) for use with nections, P/N (specify): Galvanized Semi-Assembled StandDPV-ard (specify size) Model DPV-1 Dry Pipe Groove x Groove, Valve Trim described in Figures 3, 4 Valve, P/N (see Figure 1). ANSI 2.in.( in. 5)G G.O.D.Grooves: and 5 of this document. Replacement Trim Parts Groove e (DN65)G x G..........52-310-1-925 Specify: (description) for use with GroovexGroove, Specify: 2-1/2 and 3 in. DPV-1 (specify size) Model DPV-1 Dry Pipe ANSI 3.50 in.(88,9 mm)O.D.Grooves: Semi-Assembled Galvanized Trim, 3 in.(DN80)G x G .............52-310-1-930 P/N 52-309-2-005 Valve, P/N (see Figures 3, 4, or 5). Groove x Groove, Other DPV-1 Dr Pipe Valves ANSI 4.50 in.(114,3 mm)O.D.Grooves: Specify: 4 in. DPV-1 Semi-Assembled Y p 4 in.(DN100)G x G ............52-310-1-940 Galvanized Trim, P/N 52-309-2-001 Notes: Other DPV-1 Dry Pipe Valves Flange x Groove, are valves ordered with any combi- ANSI Flange x ANSI 4.50 in.(114,3 mm)O.D. Specify: 6 in. DPV-1 Semi-Assembled nation of flange drilling, pipe groove Groove: Galvanized Trim, P/N 52-309-2-002 outside diameter(0.D.), or port thread 4 in.(DN100)F x G.............52-310-1-440 specification not offered as Standard Flange x Flange, Optional Electronic Accelerator: s p ANSI Flanges: DPV-1 Dry Pipe Valves. 4 in.(DN100)F x F.............52-310-1-040 VIZOR Electronic Dry Pipe Groove xGroove, Accelerator(with Trim) Valves with NPT threaded ports are ANSI 6.62 in.(168,3 mm)O.D.Grooves: (Ref.Technical Data Sheet TFP1105) intended for use with the Standard 6 in.(DN150)G x G ............52-310-1-960 Galvanized Semi-Assembled DPV-1 Flange x Groove, Specify: VIZOR Electronic Dry Pipe Valve Trim described in Figures 3, 4 ANSI Flange x ANSI 6.62 in.(168,3 mm)O.D. Accelerator for use with the 4 or 6 in. and 5 of this document. Valves with ISO Groove: TYCO Model DPV-1 Dry Pipe Valve threaded ports are intended for use 6 in.(DN150)F x G.............52-310-1-460 Trim, P/N 52-312-3-001 Flange x Flange, with special order trim that is provided ANSI Flanges: Optional Mechanical Accelerator: by local distributors to meet the spe- 6 in.(DN150)F x F.............52-310-1-060 Model ACCA Dry Pipe Accelerator cific needs of certain localities. Please Pre-Trimmed DPV-1 Assemblies (Ref.Technical Data Sheet TFP1112) contact your local distributor regard- with ButterflyValve regard- ing valves and valve trim for specific Specify: Model ACC-1 Dry Pipe localities. Specify: 2-1/2 in. DPV-1 Pre-Trimmed Accelerator, P/N 52-311-1-001, Valve Assembly,Grooved End Connec- and Galvanized Accelerator Trim Specify: (specify size) Model DPV-1 tions, P/N 52-310-3-925 for Model DPV-1 Dry Pipe Valve, Dry Pipe Valve with(specify) End Con- Specify:3 in. DPV-1 Pre-Trimmed Valve P/N 52-311-2-010 nections and (specify NPT or ISO) Assembly, Grooved End Connections, Optional 600 PSI Water Pressure threaded ports, P/N (specify): P/N 52-310-3-930 Gauge: Other 2-1/2 in. (DN65)Valves Specify:4 in. DPV-1 Pre-Trimmed Valve Specify: 600 PSI Water Pressure with NPT Threaded Ports Assembly, (specify) End Connection, Gauge, P/N 92-343-1-004 Groove x Groove, s ecif 3.00 in.(76,1 mm)O.D. P/N (specify): Grooves.....................52-309-1-930 Flange x Flange...............52-310-3-040 Flange x Groove...............52-310-3-440 Groove x Groove..............52-310-3-940 TFP1020 Page 20 of 20 Other 2-1/2 in. (DN65)Valves Other 4 in. (DN100)Valves Other 6 in. (DN150)Valves with ISO Threaded Ports with ISO Threaded Ports with ISO Threaded Ports Groove x Groove, Groove x Groove, Groove x Groove, ANSI 2.88 in.(73,0 mm)O.D. ANSI 4.50 in.(114,3 mm)O.D. ANSI 6.62 in.(168,3 mm)O.D. Grooves.....................52-309-1-920 Grooves.....................52-309-1-923 Grooves.....................52-309-1-925 Groove x Groove, Flange x Groove, Groove x Groove, 3.00 in.(76,1 mm)O.D. ISO Flange x ANSI 4.50 in.(114,3 mm)O.D. 6.50 in.(165,1 mm)O.D. Grooves.....................52-309-1-940 Groove......................52-309-1-213 Grooves.....................52-309-1-945 Flange x Flange, Flange x Groove, Other 3 in.(DN80)Valves ISO Flanges..................52-309-1-113 ISO Flange x ANSI 6.62 in.(168,3 mm)O.D. with ISO Threaded Ports O Groove......................52-309-1-215 Other 6 in. DN150 Groove x Groove, ( )Valves Flange x Groove, ANSI 3.50 in.(88,9 mm)O.D. with NPT Threaded Ports ISO Flange x 6.50 in.(165,1 mm)O.D. Grooves.....................52-309-1-922 Groove x Groove, Groove......................52-309-1-315 DN100 Valves 6.50 in.(165,1 mm)O.D. Flange x Flange, Other 4 in. ( ) Grooves.....................52-309-1-935 ISO Flanges..................52-309-1-115 with NPT Threaded Ports Flange x Groove, Flange x Groove, ANSI Flange x 6.50 in.(165,1 mm)O.D. ISO Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-435 Groove......................52-309-1-253 Flange x Groove, Flange x Groove, ISO Flange x ANSI 6.62 in.(168,3 mm)O.D. AS Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-255 Groove......................52-309-1-613 Flange x Groove, Flange x Groove, ISO Flange x 6.50 in.(165,1 mm)O.D. JIS Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove......................52-309-1-335 Groove......................52-309-1-813 Flange x Groove, Flange x Flange, AS Flange x ANSI 6.62 in.(168,3 mm)O.D. ISO Flanges..................52-309-1-133 Groove......................52-309-1-615 Flange x Flange, Flange x Groove, AS Flanges...................52-309-1-513 AS Flange x 6.50 in.(165,1 mm)O.D. Flange x Flange, Groove......................52-309-1-635 JIS Flanges ..................52-309 1-713 Flange x Groove, JIS Flange x ANSI 6.62 in.(168,3 mm)O.D. Groove......................52-309-1-815 Flange x Groove, JIS Flange x 6.50 in.(165,1 mm)O.D. Groove......................52-309-1-835 Flange x Flange, ISO Flanges..................52-309-1-135 Flange x Flange, AS Flanges...................52-309-1-515 Flange x Flange, JIS Flanges ..................52-309-1-715 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone A-215-362-0700®2018 Johnson Controls.All rights reserved.All specifications and other Information shown were current as of document revision date and are subject to change without notice. Johnson 400 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls LOCTITE is a registered trademark of Henkel Corporation tqCaRre Suppression & Building Products Technical Services 800-381-9312 1+1-401-781-8220 www.tyco-fire.com Model CV-1F Check Valves 2 to 12 Inch (DN50 to DN300) General The Model CV-1F Check Valves described herein must be installed Descry t/on and maintained in compliance with this N document and with the applicable stan- The TYCO Model CV-1 F Check Valve is dards of the National Fire Protection a compact and rugged swing-type unit Association, in addition to the stan- that allows water flow in one direction dards of any authorities having juris- and prevents flow in the opposite direc- diction. Failure to do so may impair the o' tion. A resilient elastomer seal facing performance of this device. on the spring-loaded clapper ensures Owners are responsible for maintain- a leak-tight seal and non-sticking oper- ing their fire protection system and ation.The Model CV-1 F Check Valves devices in proper operating condition. are designed to minimize water hammer The installing contractor or manufac- • caused by flow reversal. turer should be contacted with any The Model CV-1F Check Valve is questions. furnished with grooved ends and can be installed using Grinnell Grooved Technical Couplings or GRINNELL Figure 71 Installation Flange Adapters. The Model CV-1F Data Check Valves have been designed The Model CV-1 F Check Valves are with a removable cover for ease of field to be installed in accordance with the maintenance. These valves can be Approvals following instructions: installed horizontally(with cover in the UL, C-UL, and FM g upward position)or vertically with the Sizes 1.The arrow cast on the Body must flow in the upward direction. Refer to 2 to 12 Inch (DN50 to DN300) point in the direction of the flow. Figure 4. 2.Valves installed vertically must be Maximum Working Pressure positioned with the flow in the up- A Maintenance Check Valve Kit 300 psi (20,7 bar) ward direction. (TFP1555) is available to allow the maintenance procedure of back- Valve Assembly Finish 3.Valves installed horizontally must be flushing through the fire department Red, non-lead paint positioned with the Cover facing up. connection without removing the Model Refer to Figure 4. CV-1F Check Valve from the pipe line. 4.Grooved end pipe couplings used The Model CV-1F Check Valves area with the Model CV-1F Check Valve redesign for the Central Figure 590F must and GRINNELL Figure 590F. manufacturer's instructions. be installed in accordance with EMM Never remove any piping component nor correct or modify any piping defi- ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 4 OCTOBER 2010 TFP1550 TFP1550 Page 2 of 4 B A C O ♦ O.D. D — NPT 1/2" NPT j E F Nominal Pipe Size Nominal Dimensions Inches(mm) Cover Approx. Bolt Torq. Weight ANSI O.D. Lbs.-ft. Lbs. Inches Inches A B C D E F J (Nm) (kg) DN (mm) 2 2.375 6.75 4.38 2.55 2.57 3.25 4.75 1.62 18 9.0 DN50 (60,3) (171,5) (111,3) (64,8) (65,3) (82,3) (120,7) (41,5) (25) (4,5) 2-1/2 2.875 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.0 DN65 (73,0) (203,2) (147,3) (86,6) (86,4) (98,6) (152,4) (43,2) (54) (4,5) 76,1 - 8.00 5.80 3.41 3.40 3.88 6.00 1.70 39 10.00 DN65 (76,1) (203,2) (147,3) (86,6) (86,4) (98,6) (152,4) (43,2) (54) (4,5) 3 3.500 8.37 5.76 3.60 3.40 3.88 6.00 1.70 39 11.0 DN80 (88,9) (212,6) (146,3) (91,4) (86,4) (98,6) (152,4) (43,2) (54) (5,0) 4 4.500 9.63 6.74 4.61 3.63 4.56 7.13 1.84 50 25.0 DN100 (114,3) (244,6) (171,2) (117,1) (92,2) (115,1) (181,1) (46,7) (69) (11.3) 139.7 - 10.50 7.50 5.29 4.20 4.90 7.60 1.90 39 29.0 DN125 (139.7) (266,7) (190,5) (134,4) (106,7) (124,5) (193,0) (48,3) (54) (13.2) 5 5.563 10.50 7.50 5.29 4.20 4.90 7.60 1.90 39 29.0 DN125 (141,3) (266,7) (190,5) (134,4) (106,7) (124,5) (193,0) (48,3) (54) (13,2) 165.1 - 11.50 8.05 5.75 4.50 5.00 7.60 1.48 60 47.0 DN150 (165.1) (292,1) (204,5) (146,1) (114,3) (127,0) (193,0) (37,6) (82) (21,3) 6 6.625 11.50 8.05 5.75 4.50 5.00 7.60 1.48 60 47.0 DN150 (168,3) (292,1) (204,5) (146,1) (114,3) (127,0) (193,0) (37,6) (82) (21,3) 8 8.625 14.00 10.25 7.75 5.62 5.45 8.40 2.20 120 66.0 DN200 (219,1) (355,6) (260,4) (196,9) (142,7) (138,4) (213,4) (58,9) (164) (29,9) 10 10.750 18.00 13.00 10.21 6.38 7.50 10.50 3.00 130 109.7 DN250 (273,1) (457,2) (330,2) (259,3) (162.1) (190.5) (266,7) (76,2) (178) (49,4) 12 12.750 21.00 14.28 11.31 7.26 7.62 10.62 2.75 130 151.0 DN300 (323,9) (533,4) (362,7) (287,2) (184,4) (193,5) (269,7) (69.9) (178) (68,0) FIGURE 1 MODEL CV-1F CHECK VALVES NOMINAL DIMENSIONS TFP1550 Page 3of4 8 8 4,16 18 17 9 5 2 SEE 2 7 9 VIEW A 3 2"-8" 2 10"-12" 7 5 (DN50-DN200) (DN250-DN300) VIEW A 13 D 5 13 SEE , 11,16 DETAIL B 11 14,16 19 6 5 6 1 15 2"-8" 10"-12" (DN50-DN200) (DN250-DN300) DETAIL B Detail Part Material Oty. Detail Part Material Oty. Detail Part Material Qty. 1 Body Ductile Iron 1 6 Clapper EPDM 1 14 Locknut Stainless 1 Facing Grade"E" Steel 2 Cover Ductile Iron 1 7 Spring Stainless 1 15 Plug- Cast Iron 2 Steel 1/2-14 NPT 3 Cover Nitrile Rubber 1 8 Hinge Stainless 1 16 Adhesive Thread AR Gasket Shaft Steel Sealer Hex Cap Steel,Zinc AR 9 Retaining Stainless AR 17 Nameplate Aluminum 1 4 Screw Plated Ring Steel Clapper Stainless Retention Stainless 2 -8 Steel 11 Bolt Steel 1 18 Rivet Steel 2 5 (DN50-200) 1 Clapper Retaining Stainless Stainless 10"-12- Ductile Iron 13 Disc Steel 1 19 Spacer Steel 1 (DN250-300) FIGURE 2 MODEL CV-IF CHECK VALVES ASSEMBLY FLOW RATE IN LITRES PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 4.0 0 0 0,30 h = Q o a a 3.0 V� o z `? 1 vz Q2 ^rye o z _ �h o Q rr 2.0 ry 20 Q= o0 o m �z ° 20 VZ =� o W 00 W CJ h _ O h p `° QC Co � =`v �0 0,10 o a w 20 2 0,09 W ii zEL cn cb U� 0,08 d u) z 1.0 0= ?V 0,07 Q a O 0.9 '� JCL 0,06 ? a 0.8 :5i z 0.7 I I III !HAW0'05 0.6 0,04 0.5 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) FIGURE 3 MODEL CV-1F CHECK VALVES PRESSURE LOSS DATA TFP1550 Page 4 of 4 Care and Limited TFSBP was informed about the possi- bility of such damages, and in no Maintenance Warranty event shall TF liability exceed an amount equal too the the sales price. Products manufactured by Tyco Fire The foregoing warranty is made in lieu Suppression & Building Products of any and all other warranties. express Before closing a fire protection system (TFSBP) are warranted solely to the or implied, including warranties of main control valve for maintenance original Buyer for ten(10)years against merchantability and fitness for a partic- work on the fire protection system defects in material and workmanship ular purpose. that it controls, obtain permission to when paid for and properly installed shut down the affected fire protection and maintained under normal use This limited warranty sets forth the system from the proper authorities and and service. This warranty will expire exclusive remedy for claims based on notify all personnel who may be affect- ten (10) years from date of shipment failure of or defect in products, materi- ed by this decision. by TFSBP. No warranty is given for als or components,whether the claim is products or components manufac- made in contract,tort, strict liability or After placing a fire protection system tured by companies not affiliated by any other legal theory. in service, notify the proper authorities ownership with TFSBP or for products This warranty will apply to the full and advise those responsible for moni- and components which have been extent permitted by law.The invalidity, toring proprietary and/or central station subject to misuse, improper instal- in whole or part, of any portion of this alarms. lation, corrosion, or which have not warranty will not affect the remainder. Responsibility lies with owners for the been installed, maintained, modified inspection,testing,and maintenance of or repaired in accordance with appli- Ordering their fire protection system and devices cable Standards of the National Fire in compliance with this document, as Protection Association,and/or the stan- procedure well as with the applicable standards of dards of any other Authorities Having the National Fire Protection Association Jurisdiction. Materials found by TFSBP Contact your local distributor for avail- (for example, NFPA 25), in addition to to be defective shall be either repaired ability.When placing an order, indicate the standards of any authority having or replaced, at TFSBP's sole option. the full product name and Part Number jurisdiction. The installing contractor TFSBP neither assumes, nor authorizes (P/N). or product manufacturer should be any person to assume for it, any other contacted relative to any questions. obligation in connection with the sale of Model CV-1F Check Valves Any impairments must be immediately products or parts of products.TFSBP Specify: size and P/N (below). corrected. shall not be responsible for sprinkler p p 2"(DN50)...............P/N 59-590-0-020 or Automatic sprinkler systems are recom- system design errors or inaccurate incomplete information supplied by y 2-1/2-(DN65)............P/N 59-590-0-025 mended to be inspected, tested, and 76,1 mm(DN65) .........P/N 59-590-0-076 maintained by a qualified Inspection Buyer or Buyer's representatives. 3-(DN80)...............P/N 59-590-0-030 Service in accordance with local In no event shall TFSBP be liable, in 4-(DN100)..............P/N 59-590-0-040 requirements and/or national codes. contract, tort, strict liability or under 139,7 mm(DN125) .......P/N 59-590-0-139 any other legal theory, for inciden- 5-(DN125)..............P/N 59-590-0-050 tal, indirect, special or consequential 165,1 mm(DN150) .......P/N 59-590-0-165 damages, including but not limited to 6-(DN150)..............P/N 59-590-0-060 labor charges, regardless of whether 8 (DN200)..............P/N 59-590-0-080 10-(DN250).............P/N 59-590-0-100 12-(DN300).............P/N 59-590-0-120 OUTLET COVER FLOW i O INLET - OUTLET COVER _ ( 0� INLET FLOW VERTICAL ORIENTATION HORIZONTAL ORIENTATION FIGURE 4 MODEL CV-1F CHECK VALVES INSTALLATION Copyright© 2008-2010 Tyco Fire Suppression&Building Products.All rights reserved. CP� POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use(See Note 1) -400 to 150OF(-401 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires DC Bells-Terminal strip * APPa°°E Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30'to 150°F(-341 to 661C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. A WA R N I N G In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5400776-REV Y PAGE 1 OF 2 5/08 (E) POTTER BELLS ® The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS 10" WHITE(IN) WHITE(OUT) ° 8" I (200) FROM CONTROL 6" I I PANEL OR (150) I PRECEDING BELL I I o BLACK(OUT)BLACK(E� VOj CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 211/16" (68) DWG#776-1 NOTES: 1.WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2.END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWGtt 7763 Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance 0 5 3/4" _ 3 3/8" 5" To Next (146) 0 (86) (127) Device or End-of-Line Resistor 3 3/8" 1 5/8, (8� (41) 4 1/4" (108) Installation DWG#776-2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. O 2. Remove the gong. o 3. Connect wiring(see Fig.3). 0 4. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). ° 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). l 6. Test all bells for proper operation and observe that they can BBx-1 / be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 Spare Sprinkler Head Storage Cabinet 111S1S7r-_1L FPPI° Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts"to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Material: Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct Painted Plain Steel number of spare sprinkler is as follows: Finish: 0-300 sprinklers, not less than 6; 300-1000, not less than 12; 1000 or more, Red enamel not less than 24. Stock of spare sprinklers shall include all types and ratings Styles: installed.* 3 Spare sprinklers, '/2 or 3/4 6 Spare sprinklers, '/2 or 3/4 6 Spare, ESFR, 1/2, 3/4 or 1" Once the correct Spare Sprinkler Head Cabinet has been selected, installation 12 Spare sprinklers'/2 or 3/ is accomplished by inserting the correct fastener in each of the two holes inside 24 Spare sprinklers the cabinet, securing the cabinet securely to the wall. The insert the correct 36 Spare sprinklers number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. TT AT AT U Schedule • and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal .- Size (in) Nominal O.D. 1 1.315 1.097 1.41 Ibs/ft 91 1 1/4 1.660 1.442 1.81 Ibs/ft 61 1 1/2 1.900 1.682 2.09 Ibs/ft 61 2 2.375 2.157 2.64 Ibs/ft 37 2 1/2 2.875 2.635 3.53 Ibs/ft 30 3 3.500 3.260 4.34 Ibs/ft 19 4 4.500 4.260 5.62 Ibs/ft 19 Schedule 40 Pipe 116� Nominal Pipe Size (in) Nominal O.D. (in) 1 1.315 1.049 1.68 Ibs/ft 70 1 1/4 1.660 1.380 2.27 Ibs/ft 51 1 1/2 1.900 1.610 2.72 Ibs/ft 44 2 2.375 2.067 3.66 Ibs/ft 30 2 1/2 2.875 2.468 5.80 Ibs/ft 30 3 3.500 3.068 7.58 Ibs/ft 19 4 4.500 4.026 10.80 Ibs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. QiIZ 1819 Clarkson Road Foradditonal inforpmation, C �L usA Chesterfield, MO 63017 contact our salesperson (800)325-4467 today at(800)325-4467 or LISTED BULL MOOSE TUBE COMPANY FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada F M A UP- company e-mail: sales(c�bullmoosetube.com call(800)882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 BULL MOOSE® EDDY FLOW SPRINKLER PIPE SUBMITTAL DATA SHEET TUBE APPROVALS AND SPECIFICATIONS FINISHES AND COATINGS • ASTM A135, Grade A • Eddy Flow Sprinkler Pipe receives an OD mill coating of water-based • ASTM A795,Type E, Grade A paint which has corrosion protection expected with a painted carbon • Pressure rated to 300 psi steel product, i.e. it would be expected to resist corrosion for an • Underwriters Laboratories— extended and indefinite period in a clean and dry environment and, United States of America as environmental conditions deteriorate,the corrosion protection • Underwriters Laboratories—Canada would also diminish. • Factory Mutual • Eddy Flow Sprinkler Pipe (black) receives an ID mill coating of Eddy • NFPA-13 Guard II MIC preventative coating. EG2 has been tested at • NFPA-13R independent laboratories to resist bacterial growth and maintain • NFPA-14 minimal bacterial count after multiple flushes (25) of the pipe. • CIVIL DEFENSE APPROVAL— • Eddy Flow Sprinkler Pipe when Hot Dip Galvanized by ASTM A123 United Arab Emirates and supplied by Bull Moose Tube is UL listed and FM approved. • Made in the United States of America PRODUCT IDENTIFICATION • UL, ULC&FM listed for roll-groove, plain-end and welded joints for wet, dry, Every length of BUII Moose fire sprinkler pipe features large, easy-to- preaction and deluge sprinkler systems. read, continuous stenciling, clearly identifying the manufacturer,type • LEED v4 Certified of pipe,size,and length. mom 1.660 1.900 2.375 2.875 3.500 4.500 1.530 1.728 2.203 2.705 3.334 4,310 7 JEMPtVWe'11gJnT(10F1.222 1.844 2.330 2.809 3.361 4,968 Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7,144 11.290 C.R.R.* 1.98 3.44 2.78 1.66 1.00 1.00 Pieces per Lift 61 61 37 30 19 19 *Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY U1 C U1 FM L SUBMITTAL INFORMATION Project Contractor Engineer Specification Reference Date System Type Locations Comments O Eddy Flow-Black Eddy Flow-Hot Dip Galvanized BULLT/[OOSETUBE. - 00 00 115 Standard Duty - i The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines,including CPVC pipes, in fire sprinkler systems.A knurled insert nut helps simplify vertical adjustments and flared edges on the base(1/2"to 4"sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe(1/2"to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non-insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA°for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society(MSS)SP-58(Type 10) �- -RS C 8 A OD �F Material:Steel FM Finish: Pregalvanized C UL US wv►•oveo Outer Diameter Rod Size Static Load Part Number Pipe Size OD RS A f3 C F Certifications 1150050EG 1/2" 0.840" 3/8" 213/16" 11/8" 1" 3001b cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 1b cULus,FM 1150100EG 1" 1.315" 3/8" 3 1/4" 1 3/8" 15/16'* 3001b cULus,FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 1b cULus,FM 1150150EG 1 1/2" 1.900" 3/8" 3 13/16" 1 5/8" 15/16" 300 lb cULus,FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 lb cULus,FM 1150250EG 2 1/2" 2.875" 3/8" 5 15/16" 3 7/16" 2" 5251b cULus,FM 115030DEG 3" 3.500" 3/8" 6 9/16" 3 1/2" 1 15/16" 525 lb cULus,FM 1150350EG 3 1/2" 4.000" 3/8" 7 1/16" 3 3/4" 1 15/16" 585 lb cULus,FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 650 lb cULus,FM 1150500EG 5" 5.563" 1/2" 9 13/16" 4 3/4" 2 1/4" 1,000[b cULus,FM 1150600EG 6" 6.625" 1/2" 11 5/16" 6 5/16" 3 5/16" 1,000 lb cULus.FM 1150800EG 8" 8.625" 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus,FM nJent CADDY FM is a registered certification mark of FM Approvals LLC,LTD.NFPA is a registered trademark of National Fire Protection Association,Inc.UL,UR,cUL,cUR,cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials,Instruction sheets are available at www.erico.com and from your nVent customer service representative.Improper installation,misuse,misapplication or other failure to completely follow nVent'a instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ®2019 nVent All rights reserved nVent,nVent CADDY,nVent ERICO,nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners.nVent reserves the right to change specifications without prior notice. v, mkiri CADDY / • © Seismic Braces V `11111�:p Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Material Specifications Size Range Service Pipe Size:T'-12,DN25-DN100 - Material Carbon Steel Clamp and Hardware.Ductile Iron Brace Member Attachment Fitting. r Finish s ❑ Plain ❑ Clamp:Hot Dipped Galvanized per ASTM A153 cL us Fnn ❑ Brace Member Attachment Fitting: LISTED APPROVED Electro-Galvanized per ASTM B633 A Service A seismic longitudinal and lateral brace clamp designed to connect a piping system to a brace O O member.The AF730 rigidly braces piping systems subjected to horizontal and vertical seismic loads. Y Approvals cULus Listed(ANSI/UL 203a)and FM Approved (FM 1950-13).FM Tested(ANSI/FM 1950-16). FIG.AF730 Dimensions and Weight Complies with NFPA 13,ASCE 7,IBC,&MSS SP-127 bracing requirements. Size A B Y Weight Features In./mm In./mm In./mm Ibs/kgs Torque offset screw and nuts provide a visual 1"(DN25) 7.6 193 2.49 1.13 indication that the desired installation torque 11/2"(DN32) 8.0 203 2.55 1.13 values have been achieved. 11/2" DN40 8.2 208 2.64 1.20 ordering ( ) Specify figure number,service pipe size,finish, 2"(DN50) 8.7 221 2.78 1.26 and description. 21/2" 9.2 234 2.92 1.32 DiscLaimer: ASC Engineered Solutions does not provide any warranties 3"(DN80) 9.8 249 3.13 1.42 and specifically disclaims any liability whatsoever with 1.50 38.1 1.91 48.5 respect to ASC bracing products and components that 4"(DN100) 10.8 274 3.38 1.53 are used in combination with products,parts or systems not manufactured or sold by ASC.In no event shall ASC 5" 12.1 307 3.81 1.73 be liable for any incidental,direct,consequential,special or indirect damages or lost profits where non-ASC bracing 6" 13.2 335 4.12 1.87 components have been,or are used. 8" 15.2 386 6.40 2.90 Seis Brace®Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com 10" 18.1 460 7.60 3.45 12" 20.1 511 8.60 3.90 Notes: ASC Engineered Solutions*"^brand bracing components are designed to be compatible ONLY with other AFCON� ASC Engineered Solutions brand bracing components,resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.uL.com and updated FM approval information may be viewed at www.approvaLguide.com. An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-07.20 page 1 SS-SUB-AF730-v04 20221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 cULus Listing per ANSI/UL 203a(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service V.,O `11111�:p Size Pipe Pipe 30°-44° 45`-59` 60°-90° Listed 30`-44` 45°-59° 60°-90° Listed VAN VAN VAN IVAN IVAN VAN VAN VAN Sch.A Mega-Thread 1 Sch.40 MLT/GL 340 480 588 680 340 480 588 680 (DN25) Metric Pipe Eddy Thread 1.51 2.14 2.62 3.02 1.51 2.14 2.62 3.02 EZ-Thread Mega-Flow O Sch.10 MLT/GL 11/4 Sch.40 Mega-Thread (DN32) Metric Pipe EEddd Flow Longitudinal Application ThreaEZ-Thread Mega-Flow MLT/GL 11/2 Sch.10 Mega-Thread Sch.40 Eddy Flow 375 530 649 750 375 530 649 750 (DN40) Metric Pipe Eddy Thread 1.67 2.36 2.89 3.34 1.67 2.36 2.89 3.34 Fire-Flo EZ-Thread Mega-Flow MLT/GL 2" Sch.10 Mega-Thread (DN50) Sch.40 Eddy Flow Metric Pipe Eddy Thread Fire-Flo 0 EZ-Thread Mega-Flow 21/2 Sch.10 Eddy Flow Sch.40 Fire-Flo Lateral Application 545 770 943 1090 545 770 943 1090 Sch.10 Mega-Flow 2.42 3.43 4.19 4.85 2.42 3.43 4.19 4.85 3 Sch.40 Eddy Flow (DN80) Metric Pipe Fire-Flo 4„ Sch.10 Mega-Flow (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 51, Sch.10 _ Sch.40 Sch.10 942 1333 1632 1885 942 1333 1632 1885 6 Sch.40 Mega-Flow 4.19 5.93 7.26 8.38 4.19 5.93 7.26 8.38 Sch.10 8" 0.188"Wall - Riser Application Sch.40 10" 0.188"Wall _ Sch.40 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. ®© Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes&UL Listed metric service pipes. asc-es.com See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA13-2019 Section A.18.5.2.3. BUILdIng connections that Last' All load ratings may be used for NFPA 13-2016 designs. SS-07.20 page 2 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces MC Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 FIG.AF730 FM Approved(Listing)per FM 1950-13(ASD) Horizontal Load Rating at Brace Angle Service Standard Specialty Longitudinal Load Rating Lateral Load Rating Pipe Service Service VAO %IIZ:P Size Pipe Pipe 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN Ibf/kN bf/kN Sch.10 Mega-Thread V Sch.40 MLT/GL 550 640 670 740 1740 2460 3010 3360 (DN25) Metric Pipe Eddy Thread 2.24 2.84 2.98 3.29 7.74 10.94 13.39 14.95 EZ-Thread Mega-Flow 0 Sch.10 MLT/GL 1Y4" Sch.40 Mega-Thread 740 680 820 1620 1430 2020 2480 2770 (DN32) Metric Pipe Eddy Flow 3.29 3.02 3.65 7.21 6.36 8.99 11.03 12.32 Eddy Thread Lon itudinatA EZ-Thread g ppllcatlon Mega-Flow Sch.10 MLT/GL 1v2" Sch.40 Mega Thread Y 800 650 790 1800 1790 2530 3100 3460 ( ) DN40 Metric Pipe Eddy Flow Eddy Thread 3.56 2.89 3.51 8.01 7.96 11.25 13.79 15.39 Fire-Flo EZ-Thread Mega-Flow Sch.10 MLT/GL 2" Sch.40 Mega Thread Y 830 990 1190 1620 1820 2580 3160 3530 ( ) DN50 Metric Pipe Eddy Flow Eddy Thread 3.69 4.4 5.29 7.21 8.1 11.48 14.06 15.7 Fire-Flo EZ-Thread 2h' Sch.10 Edda Flow 800 700 850 1930 1610 2280 2790 3120 Sch.40 Fire-Flo 3.65 3.11 3.78 8.59 7.16 10.14 12.41 13.88 Sch.10 Mega-Flow Lateral Application 3" Sch.40 EddyFlow 960 1330 1540 1700 1550 2200 2690 3010 (DN80) Metric Pipe Fire-Flo 4.27 5.92 6.85 7.56 6.89 9.79 11.97 13.39 4" Sch.10 Mega-Flow 760 1040 1270 1400 1260 1790 2190 2440 (DN100) Sch.40 Eddy Flow Metric Pipe Fire-Flo 3.38 4.63 5.65 6.23 5.6 7.96 9.74 10.85 51, Sch.10 _ 890 1230 1410 1550 1260 1790 2190 2440 Sch.40 3.96 5.47 6.27 6.89 5.6 7.96 9.74 10.85 6„ Sch.10 Mega-Flow 700 940 1140 1310 950 1340 1640 1830 Sch.40 3.11 4.18 5.07 5.83 4.23 5.96 7.3 8.14 8„ 0.188"Wall _ 990 1130 1360 1520 1540 2170 2660 2970 Sch.40 4.4 5.03 6.05 6.76 6.85 9.65 11.82 13.21 10" 0.188"Wall _ 1020 850 1000 1100 1700 2410 2950 3290 Riser Application Sch.40 4.54 3.78 4.45 4.89 7.56 10.72 13.12 14.63 12" 0.188"Wall _ 970 1010 1220 1430 1690 2390 2930 3270 Sch.40 4.31 4.49 5.43 6.36 7.52 10.63 13.03 14.55 Brace Angles are determined from Vertical. Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. [moo Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings asc-es.com by a factor of 0.68. To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of1.5. BUILdIng connections that Last" See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. SS-07.20 page 3 SS-SUB-AF730-v0420221228 AFCONO Seismic Braces rlrs:) / Engineered Solutions Longitudinal & Lateral Seismic Clamp Fig.AF730 Method 1 - Connection to Brace Member First I Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 2 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. 3 Rotate the brace assembly to the service pipe.Unbolt the back nut&bolt and rotate the clamp halves over the service pipe.Re-assemble the nut and bolt. 4 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 5 Ensure the brace angle is within the range specified. Method 2 - Connection to Service Pipe First 1 Unbolt the back nut&bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2 Hand tighten the nuts on both sides of the clamp.Evenly and alternately torque the nut until the head breaks off.It is best practice to tighten the nut at thejaw side first. 3 Slide the brace member over the lowerjaw until it contacts the back wall of the brace member attachment fitting. 4 Hand tighten the set screw until it contacts the brace member.Continue to torque the set screw until the head breaks off. FIG.AF730 cULus Listed&FM Approved Brace Members Brace Member Sizes Standards(or Equivalent) UL Listed FM Approved Sch.40 1",1 Y,",1 v2",2" ASTM A53,Al 06,Al 35,or ✓ ✓ NIPS Pipe A795 Sch.40 Metric Pipe KS D 3562 ✓ ✓ DN25,DN32, EN10255H ✓ Metric Pipe DN40,DN50 GB/T3091 ✓ AS G3454 ✓ FIG.AF730 cULus Listed&FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 ✓ ✓ KS D 3537 KS D 3562 ✓ ✓ Sch.40 G B/T 3091 ✓ GB/T 3092 DN25,DN32,DN40, JIS G3452 DN50,DN 80,DN100 ✓ EN10255M asc-es.com EN 10255H Building connections that last" ss-07.20 page 4 SS-SUB-AF730-v04 20221228 ODTOLCO" www.tolco.com 00: Fig. 1000 - "Fast Clamp" Sway Brace Attachment liorniaOStPDAp of eof California OSHPD Approved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 C �L US LISTED I PS. *Additionally(UL) approved for use to brace Schedule 7 FM sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features — Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. - Installation — The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be Maximum Design Load combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs. ment component, Fig. 980, 910 or 909 to form a complete bracing 6" size — 1265 lbs. assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. FM Approved Design Loads* Brace pipe can be installed on top or bottom of pipe to be braced. 1" - 21/2" - 600 lbs. Tighten hex nuts until leaf spring is flat. It is recommended that the 3" - 4" - 700 lbs. brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Lateral Brace TOLCOO brand bracing components are desgined to be compatible ONLY with other TOLCO®brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components, in the instance that such TOLCOO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH- 951.737.5599•FAX- 951.737.0330 CUSTOMER SERVICE•800.786.5266 www,tolco.com FireLock EZ° Rigid Coupling C&f FM yds ilu4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining.The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Nominal Size 11/a 175 365 365 365 365 32 1206 2517 2517 2517 2517 11h 175 365 365 365 365 40 1206 2517 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 21h N/A 365 365 365 365 65 2517 2517 2517 2517 76.1mm N/A N/A 365** 365 365 2517** 2517 2517 3 N/A 365 365 365 365 80 2517 2517 2517 2517 4 365 365 365 365 100 N/A 2517 2517 2517 2517 165.1mm N/A N/A 290** 232 300 1999** 1600 2068 6# N/A 290 365 232 365 150# 1999 2517 1600 2517 rt Listed/Approved for wet and dry pipe systems(>—40°F/-400C). Please refer to the Victaulic Installation Manual(1-009H_009_009V.pdf)for details concerning when supplemental lubrication is required. *` EN-10219(L)for 76.1mm size;EN-10255(M)for 165.1mm size # Regional availability only Speciality Pipe Pipe Size psi/ a Pipe Size psi/ Pipe Size /kPa BLT 1 Ya—2 300 300 EZT 1/a—2 300 300 MT 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 DF 1 Ya—4 300 300 FF 1 Ya—4 300 300 MLT 1 Ya—2 N/A 300 2068 2068 2068 2068 2068 DT 1 Ya—2 300 300 FLF 1 Ya—4 N/A 300 ST 1'/a—2 N/A 300 2068 2068 2068 2068 EF 1 Ya—4 175 175 FLT 1 Ya—2 N/A 300 STF 1'/a—4 N/A 300 1206 1206 2068 2068 EL 1 Ya—2 300 300 FLTL 1 Ya—2 N/A 300 TF 2Ya—4 N/A 300 2068 2068 1 2068 1 1 2068 ET40 1'/a—2 300 300 GL 1 Ya—2 300 300 WLS 1'/a—2 300 300 2068 2068 2068 2068 2068 2068 EZF 3-4 300 300 MF 1'/a-4 300 300 WST 1'/a-2 N/A 175 2068 2068 2068 2068 1206 XL 1'/a—2 300 300 2068 2068 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC_tau I1C REV_F 10.61_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.61 FireLook EZ° Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS No.-Size Dimensions-Inches/mm L�a e m b I ed ss St R1.660365 condition) Joint Assembled M Inches X 1 Ya 790 0.10 1 2 -3/8 x 2 1 2.95 1 4.77 2.70 1 4.63 1.93 1.4 32 42.4 2517 1 3514 2.54 -M10 x 2 75 121 69 1 118 49 1 0.7 1'/2 1.900 365 1035 0.10 2 -3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48.3 2517 4604 2.54 -M10 x 2 81 126 75 122 49 0.7 STYLE 009H PRE-ASSEMBLED 2 2.375 365 1616 0.12 2 -3/8x2 3.79 5.53 3.45 5.42 1.93 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 3.05 -M10 x 2 96 140 88 138 49 0.9 2'/2 2.875 365 2370 0.12 2 -3/8 x 2'/2 4.29 6.09 3.92 5.85 1.93 2.1 Y E L 65 73.0 2517 10542 3.05 M10 x 2'/2 109 155 100 149 49 1.0 76.1 mm 3.000 365 2580 0.12 2 -1/8 x 2 1/24.40 6.31 4.05 5.90 1.93 2.1 76.1 2517 11476 3.05 M10 x 2'/2 112 160 103 150 49 1.0 X 3 3.500 365 3512 0.12 2 -3/8 x 2'/2 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 M10 x 2'/2 125 170 116 164 49 1.0 _ 4 4.560 365 5805 0.17 2 -3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9 100 114.3 2517 25822 4.32 M10 x 2'h 151 199 141 190 55 1.3 STYLE 009H JOINT ASSEMBLED 165.1 mm 6.500 290 9623 0.17 2 -1A x 3 Ya 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 M16 x 3 Ya 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 1 2 -1A x 3 1/47.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 -M16 x 3 Ya 1 202 281 195 305 54 2.69 Working Pressure and End Load are total,from all internal and external loads,based on standard weight (ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown in the chart on page 1,specific to pipe schedule and size. t The allowable pipe separation dimension shown is for system layout purposes only.Fire Lock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel(North America,Asia Pacific) • Red enamel(Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade"E" EPDM (Type A) Fire Lock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.9UI1C® 10.61_2 REV_F FFireLock EZ° Rigid Coupling STYLE 009H GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps con- taining the"QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling.There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EZ Grade "E"Type A gaskets.These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop,that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.61 5731 REV F UPDATED 10/2011 �CtaLlIiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.61 FireLock° Fittings <&> @ LPCB See Victaulic publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-l. • Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC._tau IiC REV_I 10.03_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings DIMENSIONS �-CtoE� toE� I u CtoE WC - o o , •� TEto E oo tE �<e NO.001 NO.003 NO.002 NO.006 Size ,. 'Elbow 45'Elbow Straight Tee Cap Size Outside Diameter C to E Weight Each C to E Weight Each C to E Weight Each Thickness"T" Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs 1 Y4 1.660 0.8 0.3 32 42.4 21 1 0.1 1'/2 1.900 - - - - - 0.82 0.4 40 48.3 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 L2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 1 108 9.3 176 17.6 29 5.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id 10.03_2 REV_I IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock° Fittings FLOW DATA Size Equivalent Feet/meters of Straight Pipe t Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter Inches Inches �� �0 0.Elbow Elbow Branch Run 1'/4 I 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1 Yz 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2'/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC-tau I-id REV-1 10.03_3 A . r�FireLockO Fittings GENERAL NOTES NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009WO09H couplings, use FireLock No.006 end caps containing the"EZ" marking on the inside face or No.60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV I UPDATED 2/2010 �CtaLJIIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 Mechanical-T° Bolted Branch Outlets SEE FM �c Vd3 LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 115 top housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30OF to+230°F/-340C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+820C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iIIIIC 1I1C® REV_O 11.02_1 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Appr x. Size Dimensions Weight Each minal Size D. Inches +0.13 Inches Inches Inches Inches Inches Inches Lbs. L, F Y �Z� �� - - 2 x 1/2(a)d 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 38.1 51 64 41 136 70 1.5 V 3/4(a)❑ 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 41 136 70 1.5 1(a)n 920N 500 1.50 1.85 2.53 _ 1.61 5.35 2.75 3.0 w 25 3450 38.1 47 64 41 136 70 1.4 1 Y4(a)to g20N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 C5- I? 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y �Z� 65 x Yz(a)§d 920N 500 L50 2.21 2.74 _ 1.82 143 2.0 1 A 65 a) 3450 1.5 .1 70 46 1.6 70 1.4 3/a(a)§d 920N 500 i 1.50 2.18 2.74 _ 1.82 5.64 2.75 3.0 _ LF 20 3450 38.1 55 70 46 143 70 1A T 1(a)§n 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 25 920N 3450 38.1 52 70 46 143 70 1.4 1'/4 t(a)0 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 44.5 1 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1�/2 t(a)0 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 1'/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 Yz(a)a 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 /2(a)0 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3/4(a)a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1 (a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6--r • Sizes from 2 x 1/2'/50 x 15 mm 1'/4(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2(a)to 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)o 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3/2 x 2 920N 500 2.50 3.00 _ 3.75 2.44 6.72 3.88 _ 3.8 90 50 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/2"BSPT clearly on order. §Vds approved for fire protection services o-PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St'le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. 'tl e Ma rk 920 or E Y �Z m m 920N -0.00 TABLE CONTINUED FROM PAGE 2 - 4 1/2(a)❑ 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 V 100 x 15 920N 3450 38.1 77 90 68 178 70 1.8 r I 3/4(a)❑ 920N 500 1.50 3.00 3.56 _ 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 w 1(a)a 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 _ 25 920N 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1 Y4(a)tM 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 1 44.5 78 96 102 68 178 76 1.9 1.8 1/2(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 Y Z 2(a)to 920N 4 0 63.5 83 102 100 68 17 99 2.3 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 T 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 _ 4.00 2.69 7.34 4.63 _ 6.4 w 3450 69.9 73 102 68 186 118 2.9 1? 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 FEMALE THREADED OUTLET 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 1 1/4(a)o 500 1.75 3.08 3.78 _ 2.63 7.64 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 11/2(a)o 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 - 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 _ 2.63 7.64 4.00 4.0 in the pipe 50 3450 63.5 83 102 67 194 1 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'/2(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe; also available for use rig(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 79 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 1/2750 x 15 mm 3450 699 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 _ 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 _ 80 920 3450 88.9 97 1 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another t Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com iiiCtaILJIiiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Size Dimensions minal Size, Inches +0.13 Inches Inches Inches Inches Inches Inch'7h or es D. es y �Z� 0r mm mm mm mm mm m TABLE CONTINUED FROM PAGE 3 - 1 Yz t 500 2.00 3.78 4.50 3.30 8.23 3.25 1 7.0 i 139.7 x 40 920N 3450 50.8 96 114 - 84 209 83 3.2 - T 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 -- 50 3450 63.5 95 114 84 209 99 4.1 w 6 1 Ya(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'/z(a)trl 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 Y Z 2 5 920 4 0 69.9 110 130 130 94 10.51 118 8.3 3.4 '� 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V 76.1 mm 920 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 T 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 w 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 1/2(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 1 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 500 4.50 4.45 _ 5.38 3.63 9.40 6.12 _ 10.0 108.Omm 920 3450 114.3 1 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 _ 3.63 9.40 6.25 18.0 _ Mechanical-T cross assemblies 100 920 3450 114.3 96.80 1 146 92 239 159 ' 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with H DPE pipe t Center of run to end of fitting. • Sizes from 2 x 1/2Y50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/2'BSPT clearly on order. §Vds approved for fire protection services a-PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com ICtaUI1C° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_4 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS St le Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Inches or +0.13 Inches Inches Inches Inches Inches inch I Lbs. Lbs. E Y �Z mm 920N -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 - 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 V 165.1 x 25 920N 3450 38.1 99 116 96 237 70 3.6 V - - 1�/4II 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 w 1/2(a)tR 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 Y Z 3(a)t o 920 4 0 88.9 110 140 130 92 10.51 135 10.2 8.8 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 V T 4(a)to 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 TL 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 + 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 w 200 x 50 920 3450 69.9 138 157 159 122 316 1 114 5.3 5.3 2Y2(a)t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.7s 6.38 4.81 12.42 6.25 is.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal t Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services rt-PCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com iiictauliiiC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_O 11.02_5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and (2)for the Style 920,920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 4z Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for CvrKV Values: AP = Qz Where: AP = Qz Where: O C 2 Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(psi) V AP=Pressure Drop(Bar) Q = C x AP C =Flow Coefficient Q = K„x AP K =Flow Coefficient j Exaggerated for clarity OutletEquivalent Length of 40 Carbon Steel Pipe OUTLET SIZE (C 120)t FT C,/K,Values NOMINq AL • . � GROOVED '/z 0.840 11 15 21.3 9.4 3/4 1.050 16 20 26.7 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1'/< 1.660 50 48 32 42.7 5/z 6 42.9 41.1 1 Y2 1.900 53 53 40 48.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10/z 96 89.1 2'/2 2.875 1 119 150 65 73.0 20 12/z 102 128.5 76.1 mm 3.000 16* 161 76.1 1 1 138.1 3 3.500 249 237 80 88.9 14 15/z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. 1"FireLock-Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'dUI1C° 11.02_6 REV-0 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11 .02 Mechanical-TO Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Pi Run Size xt�al Outlet SizeJpe Rated Working Pressures—psi/kPa Size m Diameter S FTEW_ �O(Style920) (Style 920N) Inches/m Inches/mm *Inches mm ScPheldule UL IJLC dQ 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145 200 219.1 2755 1000 8 8.625 3,4 10 300 250 145 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100- 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5Y125mm,67150mm and 87200 mm diameter pipe.The Style 931 comes with a 21h"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. X.A—c—tSUIiC® REV_O 11.02_7 rM1 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV 0 UPDATED 11/2018 L+tc�u�lC® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2018 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 0 11.02_L �ZTISHURJOINTR) Threaded Fittings 1-01 www.shurjoint.com c&us FM 'W'. APNIINfO For Fire Protection pressure rating,listing,and approval information,visitShurjointwebsite, www.shurioint.com THREADED FITTINGS for details or contact your SHURJOINT Representative. Shurjoint offers a complete range of ductile iron Class 300 threaded fittings in sizes from %"to 2%". Material: Ductile iron ASTM A536 Gr. 65-45-12 and or Shurjoint ductile iron threaded fittings are 100% air ASTM A395 Gr. 65-45-15. tested underwater to ensure leak-free performance. Dimensions:ANSI B16.3 Class 150 except bushings and The Shurjoint ductile iron fitting series is UL listed plugs(1316.14), unions (B16.39)and companion flanges and FM approved, making them the right choice for (616.42). Please note wall thickness dimensions are fire protection and other general application services. subordinate to Shurjoint UL and FM pressure rating listings and approvals Threads:ANSI B1.20.1 NPT or ISO-7(BSPT) Finish: Black or electro-zinc plated • General Dimensions ' L These dimensions apply to all standard fittings, both straight and reducing. For center-to-face dimensions(*), - see fitting tables. Ductile Iron Class 300 threaded fittings are designed to the y. ' same dimensions as that of Class 150 malleable iron J E + H fittings.Though due to the superior strength characteristics, J ductile Iron fittings carry a much higher pressure rating. B j Laboratory tests confirm Shurjoint ductile iron fittings have T passed hydrostatic test pressures exceeding 6,000 psi/ 414 Bar,which is equal to four times the 1,500 psi/103 Bar as specified by ANSI B16.3 for 1%"—2"sizes. Size Band O.D. Band Width Thread Length(min) in in in in '/2 1.02 0.25 0.43 3/4 1.46 0.27 0.50 1 1.77 0.30 0.58 1'/4 2.15 0.34 0.67 1'/2 2.43 0.37 0.70 2 2.96 0.42 0.75 2%2 3.59 0.48 0.92 Installers who have not used DI threaded fittings before Burst pressure testing of DI threaded fittings(2") 0 should be instructed that the fittings are stronger than the pipe in most cases. In general DI threaded fittings require about a one-half turn less than cast iron fittings. Refer to the installation instructions for fiuther detail. Pressure-Temperature Ratin ANSI 11316.3&B16.14 Nom. Working Pressure • Rating @1 -G) Working Pressure Class �z —1":2000 psi/140 Bar 300 1%4"—2": 1500 psi/105 Bar 300 psi(20 Bar) 2'/2": 1000 psi/70 Bar *Proof test pressure:1.5 times the working pressure,non-shock cold water. I-01-1/6 Rev G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 811 ELBOW 900 Model . . 0' A--I size A Wt. BoxQ'ty in in Lbs PCs J '/2 1.12 0.25 240 L '/4 1.31 0.35 120 I 1 1.50 0.57 70 1'/4 1 1.75 1 0.97 1 40 1'/2 1 1.94 1 1.17 1 30 2 1 2.25 1 1.83 1 20 2'/2 2.70 3.34 1 10 MODEL 812 REDUCING ELBOW 900 ElbowModel 812 Reducing 90' B _ Size A B W. Box Q'ty in in in Lbs PCs ,. '/4X'/2 1.20 1.22 0.35 160 1 x'/2 1.26 1.36 0.46 110 1 x'/4 1.18 1.45 0.57 90 L P/4 x'/2 1.34 1.53 0.64 75 1'/4 x 1/4 1 1.45 1.62 0.68 60 1'/4 x 1 1.58 1.67 0.81 55 P/2 x'/2 1.41 1.66 0.84 45 1'/2 x'/4 1.52 1.75 0.90 45 1'h x 1 1.65 1.80 0.95 40 P/2 x P/4 1.82 1.88 1.10 35 2x3/4 1.60 1.97 1.19 1 30 2 x 1 1.73 2.02 1 1.47 25 2x11/2 2.02 2.16 1 1.61 20 2'/2 x 2 2.39 2.60 2.93 15 MODEL 813 ELBOW 450 ElbowModel 813 450 Size A Wt. Box Q'ty f in in Lbs PCs '/2 0.88 0.22 250 3/4 0.98 0.33 150 1 1.12 0.55 90 1'/4 1.29 0.84 50 P/2 1.43 0.92 35 2 1.68 1.63 18 2'/2 1 1.95 2.42 12 I-01-2/6 Rev.G20120315 TSHURJOINTR: Threaded Fittings 1-01 www.shugoint.com MODEL 814 TEE Model Tee - 1 Size A Wt. Box Q'ty m in Ibs PCs A '/z 1.12 0.31 150 '/a 1.31 0.48 90 1 1.50 0.81 60 1.75 1.28 35 A A� 1.94 1.72 24 01 2 2.25 2.57 12 2.70 4.44 8 MODEL 815 REDUCING TEE Model 815 Reducing Tee Size A B C W. Box in in in in Lbs PCs '/a %z 1.20 1.20 1.22 0.46 95 Yz 1 1.50 1.36 1.50 0.71 55 1 /z 1.26 1.20 1.36 0.59 80 1 '/a '/a 1.37 1.31 1.45 0.66 65 1 1.50 1.45 1.50 0.77 55 1 /z 1.26 1.26 1.36 0.64 1 65 ` '/a 1.37 1.37 1.45 0.75 60 '/z 1.34 1.26 1.53 0.79 50 1 '/a 1.45 1.37 1.62 0.88 50 1 1.58 1.50 1.67 1.01 45 1'/a 1'/a 1.75 1.67 1.75 1.25 40 '/z 1.34 1.34 1.53 0.84 45 1'/a '/a 1.45 1.45 1.62 0.99 45 1 1.58 1.58 1.67 1.12 40 '/z 1.44 1.31 1.69 0.92 40 '/a 1.50 1.37 1.75 1.01 40 1 1 1.65 1.50 1.80 1.19 30 1'/a 1.82 1.67 1.88 1.54 30 1%z 1.94 1.80 1.94 1 1.54 30 1'/ %z 1.41 1.34 1.66 1.08 40 1'A '/a 1.52 1.45 1.75 1.14 40 1 1.65 1.58 1.80 1.39 30 %z 1.41 1.41 1.66 1.10 35 1'/z '/a 1.52 1.52 1.75 1.17 35 1 1.65 1.65 1.80 1.36 30 1'/a 1.82 1.82 1.88 1.56 30 1 2 2.25 2.02 2.25 2.13 15 1'/a 2 2.25 2.10 2.25 2.22 15 %z 1.49 1.41 1.88 1.52 30 '/a 1.60 1.52 1.97 1.47 25 1'/z 1 1.73 1.65 2.02 1.63 20 2 1%z 2.02 1.94 2.16 2.09 20 2 1 2.25 2.16 2.25 2.33 15 '/z 1.49 1.49 1.88 1.56 20 1.60 1.60 1.97 1.61 20 2 1 1.73 1.73 2.02 1.80 20 P/a 1.90 1.90 2.10 2.09 20 1%z 2.02 2.02 2.16 2.24 15 2'/z 2 1 '/a 1.74 1.60 2.32 2.35 15 1-01-3/6 Rev.G 20120315 TSHURJOINT R' Threaded Fittings 1-01 www.shugant.com MODEL 815 BULLHEAD TEE Model 815 Bullhead Tee Size A B C At. Box C in in in in Lbs PCs '/4 '/4 1 1.45 1.45 1.37 0.66 65 1 1 1'/4 1.67 1.67 1.58 0.97 45 1'/z 1.80 1.80 1.65 1.15 35 1 1'/z 1.88 1.80 1.82 1.43 30 1'/4 1,/4 1%z 1.88 1 1.88 1.82 1 1.52 30 2 2.10 2.10 1.90 1.80 24 1 Yz 1'/4 2 2.16 2.10 2.02 1.94 20 1'/z 2 2.16 2.16 2.02 2.00 20 2 2 2%z 2.60 2.60 2.39 3.61 10 MODEL 816 REDUCING COUPLING Model 816 Reducing Coupling Size A Wrench Size At. Box in in in Lbs PCs : s '/4 x'/z 1.63 1'/4 0.37 150 1 x Yz 1.69 1 1/4 0.37 140 } 1 x'/4 1.37 1'/z 0.48 120 1'/4 x 3/4 2.06 1-'/z 0.59 80 1'/4 x 1 2.06 0.66 60 lYzxl 2.31 0.84 50 P/z x P/4 2.31 0.92 45 2 x 1 2.81 1.23 35 2 x 1'/4 2.81 1.28 30 2 x 1'/z 2.81 1.66 30 2'/z x 2 3.25 - 2.24 18 MODEL 817 CROSS B B--I . • - � size A B W. Box Q'ty A in in in Lbs PCs 1 1/2 1.12 1.12 0.48 90 1- 3/4 1.31 1.31 0.77 60 A 1 1.50 1.50 0.95 45 1'/4 1.75 1.75 1.43 25 1%z 1.94 1 1.94 1 1.87 1 20 2 2.25 2.25 2.86 10 A�A Model 817 Reducing Cross Size A B W. Box Qty in in in Lbs PCs 1'/xl'/a 1A 1.67 1.58 1.25 30 1'/A1 YAW 1.80 1.65 1.47 24 2x2xl xl 2.02 1.73 1.94 16 I-014/6 Rev G 20120315 TSHURJOINTR Th - " ' - ' Fittings 1-01 www.shugant.com MODEL 818 STRAIGHT COUPLING ,- Model 818 Straight Coupling Size A Wrench Size W. Box Q'ty i in in in Lbs PCs + I A /2 1.38 1'8 0.18 360 i I '/4 1.61 1%" 0.26 200 1 1.77 111/16" 0.42 110 1'/4 2.00 2" 0.57 75 1'/z 1 2.20 1 2'/4" 1 0.77 1 60 2 1 2.60 1 23/4" 1 1.17 1 30 2'/2 3.00 3%" 2.11 18 MODEL 820 CAP Model i Cap r size A VV1. Box Q'ty in m in Lbs Ya 0.89 0.14 500 I. '/4 1.00 0.20 300 1 1.18 0.33 180 1'/4 1.32 0.46 110 1'/z 1.38 1 0.57 80 2 1.48 1 0.88 1 45 2Y2 1.77 1.54 25 MODEL 825 EXTENSION PIECE Model Size A Wt. Box Q'ty in in Lbs PCs '/2 x 1'/zL 1.50 0.18 300 '/2 x 2L 2.00 0.22 250 t".., 3/4x1Y2L 1.50 0.22 250 '� 6 '/4 x 2L 2.00 0.26 200 f: AA MODEL 831 LONG STREET ELBOW 900 ElbowModel 831 Long Street • i ' all% size A B W. Box Q'ty in in in Lbs PCs i 1 x'/2M 1.50 3.00 0.66 80 g 1 x 1M 1.50 3.00 0.81 60 I-01-5/6 Rev.G 20120315 TSHURJOINTR Threaded Fittings 1-01 www.shugant.com MODEL 832 LONG STREET TEE Model 832 Long Street Tee C size A B C Wt I Box Q'ty in in in in Lbs Pes 1 x'/2XIM 1.50 1.40 3.00 0.91 50 -t-- IX1x1M 1.50 1.50 3.00 1.03 45 MODEL 827 HEX BUSHING Model 827 Hex Bushing Size A Wt. Box Q'ty in in Lbs PCs A I X'/2 1.06 0.20 280 1 x3/4 1.06 0.18 280 qW, 1'/4 X I 1.18 0.29 150 1'/2 x 1 1.26 0.53 100 Ph x P/4 1 1.26 0.37 100 2 x 1 1 1.34 0.75 80 2 x 1'/4 1 1.34 0.75 80 2 x 1'/2 1 1.34 0.64 80 MODEL 819 PLUG Model 819 Plug size A Wt. BoxQty in in Lbs PCs '/2 0.93 0.09 500 3/4 1.13 0.18 300 1 1.25 0.25 200 A 1'/4 1.36 0.42 110 1 Y2 1.45 0.59 80 2 1 1.50 1 0.95 1 45 General Notes: • Pressure ratings listed are CWP(cold water pressure)or rnaximum Aurking pressure widen the service temperature range ofthe gasket used in the coupling.This rating may occasionally differ from maximum NNurking pressures listed and/or approved by UT,ULC,and/or FM as testing conditions and test pipes differ.For additional information contact Shurjoint.. • NVhximum wutidng pressures and end loads listed are total of internal and extemal pressures and loads based on Sch. 10 steel pipe with roll grooves toANSFAWWAC606-07 specifications.For information on other pipe schedules contact Shurjoint.. • For one time field test only the maximum joint vwrking pressure may be increased 1'/2 times the figures shown. • Warning:Piping systems must always be depressurized and drained before attempting disassembly and or removal ofany components. • Shurjoint reserves the right to change specifications,designs and or standard equipment without notice and without incurring any obligations. Job Name: System No. Location: Contractor: Approved: Date: Engineer: Approved: Date: Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,please contact Shurjoint Technical Service.Shurjoint reserves the right to change or modify product design, construction, specifications,or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. I-01-6/6 Rev.G20120315 CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 1 Demand (HW) OH1 1950 751.3 Required 0.179 7 21.2 19 250 11.7 66.9 WASHINCaTON STATE ---- ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , , David Yates 2606-0898-C Level Burns Fire Protection Systems,Inc. B VS 1bU 9/6/23 Expires: 14 Signature Date 12/31/23 ................. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 1 Remote Area Location SW CORNER Occupancy Classification OH1 Density(gpm/ft2) 0.179 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 118.3 Number of Calculated Sprinklers 19 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 751.3 Required Pressure at Source(psi) 66.9 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 1 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.6 751.3 66.9 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 250 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 501.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 501.3 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 66.9 W1 -Flow(gpm) 751.3 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 a supply♦Supply;Safety Pressure f System Demand • Available At Source 10 90 78.6 psi @ 751.3 glom 00 8 � 70 ~ D2 -- C:,2 63 493 60 !Z N 7 50 fq d a 4 3 20 D1 1 10 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 1 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 13.6 D2 I System Demand 751.3 66.9 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.5 836.1 11.7 751.3 Supply;Safety Pressure 70.7 780.2 3.9 751.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 102 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 8 Sprinkler 103 Overhead 118.3 8 0.15 17.7 7 0.209 24.7 9.5 Sprinkler 104 Overhead 118.3 8 0.15 17.7 7 0.233 27.6 11.9 Sprinkler 105 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 106 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 107 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 7.9 Sprinkler 108 Overhead 118.3 8 0.15 17.7 7 0.208 24.6 9.5 Sprinkler 109 Overhead 118.3 8 0.15 17.7 7 0.233 27.5 11.8 Sprinkler 110 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 111 Overhead 118.3 8 0.15 17.7 7 0.179 21.2 7 Sprinkler 112 Overhead 118.3 8 0.15 17.7 7 0.191 22.6 7.9 Sprinkler 113 Overhead 118.3 8 0.15 17.7 7 0.208 24.6 9.5 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 114 Overhead 118.3 8 0.15 17.7 7 0.233 27.5 11.8 Sprinkler 115 Overhead 118.3 8 0.15 17.7 7 0.265 31.4 15.4 Sprinkler 116 Overhead 118.3 8 0.15 17.7 7 0.23 27.2 11.5 Sprinkler 117 Overhead 118.3 8 0.15 17.7 7 0.24 28.4 12.6 Sprinkler 118 Overhead 118.3 8 0.15 17.7 7 0.257 30.4 14.4 Sprinkler 119 Overhead 118.3 8 0.15 17.7 7 0.282 33.4 17.4 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 111 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.4 0.179 -13.6 17.7 106 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.4 0.179 -13.6 17.7 101 Overhead Sprinkler 8 21.2 118.3 7 7 28.35 HEAD Open 3.5 0.179 -13.6 17.7 112 Overhead Sprinkler 8 22.6 118.3 7.9 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 107 Overhead Sprinkler 8 22.6 118.3 7.9 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 102 Overhead Sprinkler 8 22.6 118.3 8 7 26.65 HEAD Open 4.8 0.191 -12.8 17.7 113 Overhead Sprinkler 8 24.6 118.3 9.5 7 24.95 HEAD Open 6.9 0.208 -12.1 17.7 108 Overhead Sprinkler 8 24.6 118.3 9.5 7 24.95 HEAD Open 6.9 0.208 -12.1 17.7 103 Overhead Sprinkler 8 24.7 118.3 9.5 7 24.95 HEAD Open 6.9 0.209 -12.1 17.7 116 Overhead Sprinkler 8 27.2 118.3 11.5 7 26.65 HEAD Open 9.4 0.23 -12.8 17.7 114 Overhead Sprinkler 8 27.5 118.3 11.8 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 109 Overhead Sprinkler 8 27.5 118.3 11.8 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 104 Overhead Sprinkler 8 27.6 118.3 11.9 7 23.4 HEAD Open 9.8 0.233 -11.4 17.7 117 Overhead Sprinkler 8 28.4 118.3 12.6 7 24.95 HEAD Open 10.7 0.24 -12.1 17.7 118 Overhead Sprinkler 8 30.4 118.3 14.4 7 23.4 HEAD Open 12.6 0.257 -11.4 17.7 115 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.6 0.265 -10.8 17.7 110 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.6 0.265 -10.8 17.7 105 Overhead Sprinkler 8 31.4 118.3 15.4 7 21.97 HEAD Open 13.7 0.265 -10.8 17.7 119 Overhead Sprinkler 8 33.4 118.3 17.4 7 21.97 HEAD Open 15.6 0.282 -10.8 17.7 0141 Node 34.8 17.99 NODE -9.1 0140 Node 34.8 17.96 NODE -9.1 0030 Node 34.8 18.01 NODE -9.1 0138 Node 34.9 17.94 NODE -9.1 0096 Node 43.2 18.02 NODE -9.1 0938-0 Node 50.7 5.28 NODE -3.6 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0938-I Node 52 4.14 NODE -3.1 0939-0 Node 53 2.09 INODE -2.2 0939-I Node 62.1 1.93 NODE -2.1 0940 Node 62.8 0.5 NODE -1.5 H1 Outside Hose 250 64.5 -3 IHOSE 0 250 0943 Node 64.6 -3 NODE 0 0944-0 Node 65.9 -3 NODE 0 0944-I Node 66 -3 NODE 0 0945 Node 66.5 -3 NODE 0 wi Supply -751.3 66.9 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 ill 28.35 8 21.2 1.5 11.85 100 7 112 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 112 26.65 8 22.6 1.5 11.85 100 7.9 113 24.95 8 43.7 1.728 0 0.068 0.7 11.85 0.8 113 24.95 8 24.6 1.5 10.81 100 9.5 114 23.4 8 68.4 1.728 0 0.1557 0.7 10.81 1.7 114 23.4 8 27.5 1.5 9.98 100 11.8 115 21.97 8 95.9 1.728 0 0.2914 0.6 9.98 2.9 115 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.89 100 15.4 0140 17.96 127.3 1.728 lx(90 ell)=4.02 12.07 0.4922 1.7 35.96 17.7 0140 17.96 13.9 4 10 100 34.8 0138 17.94 141.2 4.31 0 0.007 0.0 10 0.1 0138 17.94 119.3 4 5x(90 ell)=33.29 351.41 100 34.9 0096 18.02 260.5 4.31 33.29 0.0216 0.0 384.7 8.3 0096 18.02 240.8 4 2x(90 ell)=13.32 13.85 100 43.2 0938-0 5.28 501.3 4.31 13.32 0.0727 5.5 27.17 2 0938-0 5.28 0 4 1.14 50.7 DPV-1 0938-I 4.14 501.3 0 0 0.7591 0.5 *** 1.14 0.9 0938-I 4.14 0 4 2.04 120 52 0939-0 2.09 501.3 4.31 0 0.0519 0.9 2.04 0.1 0939-0 2.09 0 4 0.17 53 Ames 0939-I 1.93 501.3 0 0 54.2493 0.1 Deringer 30 0.17 9 *** 0939-I 1.93 0 4 1.43 120 62.1 0940 0.5 501.3 4.31 0 0.0519 0.6 1.43 0.1 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 62.8 0943 -3 501.3 6.4 34.91 0.0057 1.5 44.03 0.3 0943 -3 250 6 104.43 140 64.6 0944-0 -3 751.3 6.4 0 0.012 0 104.43 1.3 0944-0 -3 0 6 0.88 65.9 Gate A2360 0944-I -3 751.3 0 0 0.1131 0 *** 0.88 0.1 0944-I -3 0 6 lx(tee-Br)=43.72 1.21 140 66 0945 -3 751.3 6.4 43.72 0.012 0 44.931 0.5 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0945 -3 0 8 124.91 140 66.5 W 1 -3 751.3 8.55 0 0.0029 0 124.91 0.4 W 1 66.9 Path No: 2 106 28.35 8 21.2 1.5 11.85 100 7 107 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 107 26.65 8 22.6 1.5 11.85 100 7.9 108 24.95 8 43.7 1.728 0 0.0681 0.7 11.85 0.8 108 24.95 8 24.6 1.5 10.81 100 9.5 109 23.4 8 68.4 1.728 0 0.1558 0.7 10.81 1.7 109 23.4 8 27.5 1.5 9.98 100 11.8 110 21.97 8 95.9 1.728 0 0.2916 0.6 9.98 2.9 110 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.86 100 15.4 0141 17.99 127.3 1.728 1x(90 ell)=4.02 12.07 0.4924 1.7 35.93 17.7 0141 17.99 -13.9 4 10 100 34.8 0030 18.01 113.4 4.31 0 0.0046 0.0 10 0.0 0030 18.01 127.4 4 lx(tee-Br)=16.69 389.77 100 34.8 0096 18.02 240.8 4.31 6x(90 ell)=39.95 56.64 0.0187 0 446.421 8.4 0096 43.2 Path No: 3 101 28.35 8 21.2 1.5 11.85 100 7 102 26.65 8 21.2 1.728 0 0.0178 0.7 11.85 0.2 102 26.65 8 22.6 1.5 11.85 100 8 103 24.95 8 43.8 1.728 0 0.0682 0.7 11.85 0.8 103 24.95 8 24.7 1.5 10.81 100 9.5 104 23.4 8 68.4 1.728 0 0.1561 0.7 10.81 1.7 104 23.4 8 27.6 1.5 9.98 100 11.9 105 21.97 8 96 1.728 0 0.2921 0.6 9.98 2.9 105 21.97 8 31.4 1.5 lx(tee-Br)=8.05 23.83 100 15.4 0030 18.01 127.4 1.728 1x(90 ell)=4.02 12.07 0.4933 1.7 35.9 17.7 0030 34.8 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 116 26.65 8 27.2 1.5 11.85 100 11.5 117 24.95 8 27.2 1.728 0 0.0282 0.7 11.85 0.3 117 24.95 8 28.4 1.5 10.81 100 12.6 118 23.4 8 55.6 1.728 0 0.1061 0.7 10.81 1.1 118 23.4 8 30.4 1.5 9.98 100 14.4 119 21.97 8 85.9 1.728 0 0.238 0.6 9.98 2.4 119 21.97 8 33.4 1.5 lx(tee-Br)=8.05 23.91 100 17.4 0138 17.94 119.3 1.728 1x(90 ell)=4.02 12.07 0.437 1.7 35.99 15.7 0138 34.9 Path No: 5 H1 -3 250 6 lx(tee-Br)=43.72 1.76 140 64.5 0943 -3 250 6.4 43.72 0.0016 0 45.48 0.1 0943 64.6 Path No: 6 0141 17.99 0 4 10 100 34.8 0140 17.96 13.9 4.31 0 0.0001 0.0 10 0 0140 34.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 17.43 ft/s occurs in the following pipe(s): (0030-105) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 1; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 11.1 c. 1o.1s 9 psi @ 501.3 gpm ., m L 7 9.1 40) 8.1 L. d 7.1 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 13 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 1; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1.9 0.9psi' 501.39pm 0.9 0 0 0 0 0 0 0 0 0 0 o c o 0 o o n o n o 0 o v o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 1; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @a 751.3 gpm o c c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 14 CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 2 Demand (HW) OH2 1950 669.6 Required 0.2 18.7 24.2 16 250 8.2 70.5 -- WASHINGTON STATE - ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , , David Yates 2605.0898-C Leve13 Burns Fire Protection Systems,Inc. 8 SFPB '!bU ' / 9/6/23 rJExpires: ; S19nature Date 12/31/23 ................................ File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 2 Remote Area Location STORAGE CANOPY Occupancy Classification OH2 Density(gpm/ft2) 0.2 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 121 Number of Calculated Sprinklers 16 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl. Hose Streams)(gpm) 669.6 Required Pressure at Source(psi) 70.5 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 2 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.7 669.6 70.5 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 250 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 419.6 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 419.6 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 70.5 W1 -Flow(gpm) 669.6 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 a supply♦Supply;Safety Pressure f System Demand • Available At Source 10 90 78.7 psi @ 669.6 gpm 800 � D2 70 ~ -- C:,2 63 493 6 .y !Z N 7 50 N d a a 3 2 D1 1 1 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 2 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 9.3 D2 I System Demand 669.6 70.5 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.6 716.3 8.2 669.6 Supply;Safety Pressure 70.8 671.4 0.3 669.6 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 201 Overhead 121 5.6 0.2 24.2 18.7 0.228 27.6 24.2 Sprinkler 202 Overhead 121 5.6 0.2 24.2 18.7 0.23 27.9 24.8 Sprinkler 203 Overhead 121 5.6 0.2 24.2 18.7 0.236 28.5 25.9 Sprinkler 204 Overhead 121 5.6 0.2 24.2 18.7 0.22 26.7 22.7 Sprinkler 205 Overhead 121 5.6 0.2 24.2 18.7 0.215 26 21.6 Sprinkler 206 Overhead 121 5.6 0.2 24.2 18.7 0.212 25.7 21.1 Sprinkler 207 Overhead 121 5.6 0.2 24.2 18.7 0.2 24.2 18.7 Sprinkler 208 Overhead 121 5.6 0.2 24.2 18.7 0.202 24.5 19.1 Sprinkler 209 Overhead 121 5.6 0.2 24.2 18.7 0.208 25.1 20.1 Sprinkler 210 Overhead 121 5.6 0.2 24.2 18.7 0.251 30.3 29.3 Sprinkler 211 Overhead 121 5.6 0.2 24.2 18.7 0.222 26.8 22.9 Sprinkler 212 Overhead 121 5.6 0.2 24.2 18.7 0.216 26.2 21.8 Sprinkler 213 Overhead 121 5.6 0.2 24.2 18.7 0.214 25.9 21.3 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 214 Overhead 121 5.6 0.2 24.2 18.7 0.201 24.4 18.9 Sprinkler 215 Overhead 121 5.6 0.2 24.2 18.7 0.204 24.7 19.4 Sprinkler 216 Overhead 121 5.6 0.2 24.2 18.7 0.209 25.3 20.4 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 207 Overhead Sprinkler 5.6 24.2 121 18.7 18.7 18.49 HEAD Open 0 0.2 -9.3 24.2 214 Overhead Sprinkler 5.6 24.4 121 18.9 18.7 18.49 HEAD Open 0.2 0.201 -9.3 24.2 208 Overhead Sprinkler 5.6 24.5 121 19.1 18.7 17.86 HEAD Open 0.3 0.202 -9 24.2 215 Overhead Sprinkler 5.6 24.7 121 19.4 18.7 17.86 HEAD Open 0.5 0.204 -9 24.2 209 Overhead Sprinkler 5.6 25.1 121 20.1 18.7 17.23 HEAD Open 0.9 0.208 -8.8 24.2 216 Overhead Sprinkler 5.6 25.3 121 20.4 18.7 17.23 HEAD Open 1.1 0.209 -8.8 24.2 206 Overhead Sprinkler 5.6 25.7 121 21.1 18.7 18.48 HEAD Open 1.5 0.212 -9.3 24.2 213 Overhead Sprinkler 5.6 25.9 121 21.3 18.7 18.48 HEAD Open 1.7 0.214 -9.3 24.2 205 Overhead Sprinkler 5.6 26 121 21.6 18.7 17.82 HEAD Open 1.8 0.215 -9 24.2 212 Overhead Sprinkler 5.6 26.2 121 21.8 18.7 17.82 HEAD Open 2 0.216 -9 24.2 204 Overhead Sprinkler 5.6 26.7 121 22.7 18.7 17.15 HEAD Open 2.5 0.22 -8.7 24.2 211 Overhead Sprinkler 5.6 26.8 121 22.9 18.7 17.15 HEAD Open 2.6 0.222 -8.7 24.2 201 Overhead Sprinkler 5.6 27.6 121 24.2 18.7 18.49 HEAD Open 3.4 0.228 -9.3 24.2 202 Overhead Sprinkler 5.6 27.9 121 24.8 18.7 17.86 HEAD Open 3.7 0.23 -9 24.2 203 Overhead Sprinkler 5.6 28.5 121 25.9 18.7 17.23 HEAD Open 4.3 0.236 -8.8 24.2 210 Overhead Sprinkler 5.6 30.3 121 29.3 18.7 17.23 HEAD Open 6.1 0.251 -8.8 24.2 0946 Node 23.6 15.79 NODE -8.1 0002 Node 23.9 15.76 NODE -8.1 0011 Node 26.4 15.79 NODE -8.1 0009 Node 26.7 15.75 NODE -8.1 0008 Node 28.2 15.73 NODE -8.1 0916 Node 30.1 15.79 NODE -8.1 0915 Node 30.5 15.75 NODE -8.1 0024 Node 32 15.73 NODE -8.1 0027 Node 45.1 17.75 NODE -9 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0042 Node 45.7 19.25 NODE -9.6 0096 Node 50.8 18.02 NODE -9.1 0938-0 Node 57.8 5.28 NODE -3.6 0938-I Node 58.9 4.14 NODE -3.1 0939-0 Node 59.8 2.09 NODE -2.2 0939-I Node 66.3 1.93 NODE -2.1 0940 Node 67 0.5 NODE -1.5 H1 Outside Hose 250 68.6 -3 HOSE 0 250 0943 Node 68.7 -3 INODE 0 0944-0 Node 69.7 -3 NODE 0 0944-I Node 69.8 -3 NODE 0 0945 Node 70.2 -3 NODE 0 wi Supply -669.6 70.5 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 207 18.49 5.6 24.2 1.5 8.52 100 18.7 208 17.86 5.6 24.2 1.728 0 0.0228 0.3 8.52 0.2 208 17.86 5.6 24.5 1.5 8.52 100 19.1 209 17.23 5.6 48.7 1.728 0 0.0831 0.3 8.52 0.7 209 17.23 5.6 25.1 1.5 1x(tee-Br)=8.05 3.62 100 20.1 0946 15.79 73.8 1.728 1x(90 ell)=4.02 12.07 0.1796 0.6 15.7 2.8 0946 15.79 0 2.5 14.17 100 23.6 0002 15.76 73.8 2.705 0 0.0202 0.0 14.17 0.3 0002 15.76 74.3 2.5 1x(90 ell)=4.56 53.94 100 23.9 0008 15.73 148.1 2.705 4.56 0.0735 0.0 58.5 4.3 0008 15.73 157.2 2.5 1x(tee-Br)=11.46 2 100 28.2 0024 15.73 305.3 2.705 11.46 0.2807 0 13.46 3.8 0024 15.73 114.3 2.5 1x(tee-Br)=11.46 11.67 100 32 0027 17.75 419.6 2.705 1x(90 ell)=4.56 16.02 0.5059 -0.9 27.68 14 0027 17.75 -177.2 4 5x(90 ell)=33.29 275.7 100 45.1 0096 18.02 242.4 4.31 33.29 0.0189 -0.1 308.99 5.9 0096 18.02 177.2 4 2x(90 ell)=13.32 13.85 100 50.8 0938-0 5.28 419.6 4.31 13.32 0.0523 5.5 27.17 1.4 0938-0 5.28 0 4 1.14 57.8 DPV-1 0938-I 4.14 419.6 0 0 0.5398 0.5 *** 1.14 0.6 0938-I 4.14 0 4 2.04 120 58.9 0939-0 2.09 419.6 4.31 0 0.0373 0.9 2.04 0.1 0939-0 2.09 0 4 0.17 59.8 Ames 0939-I 1.93 419.6 0 0 38.3815 0.1 Deringer 30 0.17 6.4 *** 0939-I 1.93 0 4 1.43 120 66.3 0940 0.5 419.6 4.31 0 0.0373 0.6 1.43 0.1 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 67 0943 -3 419.6 6.4 34.91 0.0041 1.5 44.03 0.2 0943 -3 250 6 104.43 140 68.7 0944-0 -3 669.6 6.4 0 0.0097 0 104.43 1 0944-0 -3 0 6 0.88 69.7 Gate A2360 0944-I -3 669.6 0 0 0.1136 0 *** 0.881 1 0.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0944-I -3 0 6 lx(tee-Br)=43.72 1.21 140 69.8 0945 -3 669.6 6.4 43.72 0.0097 0 44.93 0.4 0945 -3 0 8 124.91 140 70.2 W 1 -3 669.6 8.55 0 0.0024 0 124.911 1 0.3 W 1 70.5 Path No: 2 214 18.49 5.6 24.4 1.5 8.52 100 18.9 215 17.86 5.6 24.4 1.728 0 0.023 0.3 8.52 0.2 215 17.86 5.6 24.7 1.5 8.52 100 19.4 216 17.23 5.6 49 1.728 0 0.0841 0.3 8.52 0.7 216 17.23 5.6 25.3 1.5 lx(tee-Br)=8.05 3.65 100 20.4 0002 15.76 74.3 1.728 1x(90 ell)=4.02 12.07 0.1816 0.6 15.73 2.9 0002 23.9 Path No: 3 206 18.48 5.6 25.7 1.5 8.53 100 21.1 205 17.82 5.6 25.7 1.728 0 0.0254 0.3 8.53 0.2 205 17.82 5.6 26 1.5 8.53 100 21.6 204 17.15 5.6 51.7 1.728 0 0.0929 0.3 8.53 0.8 204 17.15 5.6 26.7 1.5 lx(tee-Br)=8.05 3.53 100 22.7 0011 15.79 78.4 1.728 1x(90 ell)=4.02 12.07 0.2006 0.6 15.61 3.1 0011 15.79 0 2.5 14.17 100 26.4 0009 15.75 78.4 2.705 0 0.0226 0.0 14.17 0.3 0009 15.75 78.9 2.5 lx(tee-Br)=11.46 6.32 100 26.7 0008 15.73 157.2 2.705 11.46 0.0821 0 17.77 1.5 0008 28.2 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 213 18.48 5.6 25.9 1.5 8.53 100 21.3 212 17.82 5.6 25.9 1.728 0 0.0257 0.3 8.53 0.2 212 17.82 5.6 26.2 1.5 8.53 100 21.8 211 17.15 5.6 52 1.728 0 0.094 0.3 8.531 1 0.8 211 17.15 5.6 26.8 1.5 lx(tee-Br)=8.05 3.58 100 22.9 0009 15.75 78.9 1.728 1x(90 ell)=4.02 12.07 0.2029 0.6 15.65 3.2 0009 26.7 Path No: 5 201 18.49 5.6 27.6 1.5 8.52 100 24.2 202 17.86 5.6 27.6 1.728 0 0.029 0.3 8.52 0.2 202 17.86 5.6 27.9 1.5 8.52 100 24.8 203 17.23 5.6 55.4 1.728 0 0.1057 0.3 8.52 0.9 203 17.23 5.6 28.5 1.5 lx(tee-Br)=8.05 3.62 100 25.9 0916 15.79 84 1.728 1x(90 ell)=4.02 12.07 0.2279 0.6 15.7 3.6 0916 15.79 0 2.5 14.17 100 30.1 0915 15.75 84 2.705 0 0.0257 0.0 14.17 0.4 0915 15.75 30.3 2.5 2x(tee-Br)=22.91 8.32 100 30.5 0024 15.73 114.3 2.705 22.91 0.0455 0 31.23 1.4 0024 32 Path No: 6 210 17.23 5.6 30.3 1.5 lx(tee-Br)=8.05 3.67 100 29.3 0915 15.75 30.3 1.728 1x(90 ell)=4.02 12.07 0.0346 0.6 15.74 0.5 0915 30.5 Path No: 7 H1 -3 250 6 lx(tee-Br)=43.72 1.76 140 68.6 0943 -3 250 6.4 43.72 0.0016 0 45.48 0.1 0943 68.7 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 8 0027 17.75 0 4 2x(90 ell)=13.32 110.43 100 45.1 0042 19.25 177.2 4.31 13.32 0.0106 -0.6 123.75 1.3 0042 19.25 0 4 1x(tee-Br)=16.69 385.05 100 45.7 0096 18.02 177.2 4.31 4x(90 ell)=26.63 43.33 0.0106 0.5 428.381 1 4.5 0096 50.8 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 23.43 ft/s occurs in the following pipe(s): (0027-0024) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 2; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 z 11.1 Q' 10.15 L 7 9.1 N L8.1 L 6.4 psi @ 419.6 gpm d 7.1 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 14 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 2; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1100, 1.9 - 0.6 psi @ 419.6 gpm 0.9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o o n o n o 0 o v o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 2; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @ 669.6 gpm 0 o c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 15 CALCULATION SUMMARY Project Name :SEATTLE GALVANIZING PLANT Project Location: 18520 67th Ave N.E. Contract No. : City: Arlington, WA 98223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 3 Demand (HW) Ih 1950 459.3 Required 0.161 7 14.8 19 100 8.3 70.6 WASHINGTON STATE ' ' CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS , David Yates 2606-0898-C Level Burns Fire Protection Systems,Inc. B ZPB 1bU Expires: ; 9/6/23 t 2/31 R3 Sign2ture Date ................................ File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name :SEATTLE GALVANIZING PLANT Contract No. : City: Arlington, WA 98223 Project Location: 18520 67th Ave N.E. Date:5/13/2016 Contractor Information Name of Contractor: Burns Fire Protection, Inc Address: P.O.B. 1110 City: Granite Falls, Wa 98252 Phone Number: E-mail: Name of Designer: D.Yates Authority Having Jurisdiction: Arlington Design Remote Area Name 3 Remote Area Location lower mewzzanine Occupancy Classification Ih Density(gpm/ft2) 0.161 Area of Application (ft2) 1950 Coverage per Sprinkler(ft2) 91.94 Number of Calculated Sprinklers 19 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 100 Total Water Required(incl. Hose Streams)(gpm) 459.3 Required Pressure at Source(psi) 70.6 Type of System Dry Volume-Downstream DPV (gal) 1161.2 gal Water Supply Information Date 8/31/2023 Location 67th ave NE Source W 1 Notes calulations include all of lower mezzanine File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:SEATTLE GALVANIZING PLANT Node Labels: Off Pipe Labels: Off Diagram for Design Area : 3 (Optimized Hvdraulic Simplified) File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 79 5000 66 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source (psi) Pressure (gpm) Pressure (gpm) (psi) (psi) (psi) W1 79 66 5000 78.8 459.3 70.6 Hoses Inside Hose Flow/Standpipe Demand(gpm) 0 Outside Hose Flow(gpm) 100 Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Hose Flow(gpm) 100 Sprinklers Ovehead Sprinkler Flow(gpm) 359.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Total Sprinkler Flow(gpm) 359.3 Other Required Margin of Safety(%) 10 W1 -Pressure(psi) 70.6 W1 -Flow(gpm) 459.3 Demand w/o System Pump(s) N/A File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 4 Job :SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 a supply♦Supply;Safety Pressure f System Demand • Available At Source 100 90 78.8 psi @ 459.3 gpm 80 D2 70 63 493 6 .y !Z N 7 50 N d a a 3 20 D1 1 0 0 1500 2000 2500 3000 3500 4000 4500 5000 5500 Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 5 Job:SEATTLE GALVANIZING PLANT Hydraulic Analysis for : 3 Graph Labels Values Label Description Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 79 S2 Supply point#2-Residual 5000 66 D1 Elevation Pressure 0 4.4 D2 I System Demand 459.3 70.6 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 78.8 489.5 8.3 459.3 Supply;Safety Pressure 71 460.9 0.4 459.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 301 Overhead 91.94 5.6 0.1 9.2 7 0.168 15.4 7.6 Sprinkler 302 Overhead 91.94 5.6 0.1 9.2 7 0.172 15.9 8 Sprinkler 303 Overhead 91.94 5.6 0.1 9.2 7 0.206 18.9 11.4 Sprinkler 304 Overhead 91.94 5.6 0.1 9.2 7 0.197 18.1 10.4 Sprinkler 305 Overhead 91.94 5.6 0.1 9.2 7 0.196 18 10.3 Sprinkler 306 Overhead 91.94 5.6 0.1 9.2 7 0.207 19 11.6 Sprinkler 307 Overhead 91.94 5.6 0.1 9.2 7 0.166 15.3 7.4 Sprinkler 308 Overhead 91.94 5.6 0.1 9.2 7 0.166 15.3 7.4 Sprinkler 309 Overhead 91.94 5.6 0.1 9.2 7 0.229 21 14.1 Sprinkler 310 Overhead 91.94 5.6 0.1 9.2 7 0.168 15.4 7.6 Sprinkler 311 Overhead 91.94 5.6 0.1 9.2 7 0.192 17.7 10 Sprinkler 312 Overhead 91.94 5.6 0.1 9.2 7 0.165 15.1 7.3 Sprinkler 313 Overhead 91.94 5.6 0.1 9.2 7 0.173 15.9 8.1 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright @ 2002-2012 Tyco Fire Protection Products Page 6 314 Overhead 91.94 5.6 0.1 9.2 7 0.263 24.2 18.6 Sprinkler 316 Overhead 91.94 5.6 0.1 9.2 7 0.162 14.9 7.1 Sprinkler 318 Overhead 91.94 5.6 0.1 9.2 7 0.284 26.1 21.8 Sprinkler 319 Overhead 91.94 5.6 0.1 9.2 7 0.161 14.8 7 Sprinkler 321 Overhead 91.94 5.6 0.1 9.2 7 0.326 30 28.6 Sprinkler 322 Overhead 91.94 5.6 0.1 9.2 7 0.308 28.3 25.5 Sprinkler File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 319 Overhead Sprinkler 5.6 14.8 91.94 7 7 7.17 HEAD Open 5.6 0.161 -4.4 9.2 316 Overhead Sprinkler 5.6 14.9 91.94 7.1 7 7.17 HEAD Open 5.7 0.162 -4.4 9.2 312 Overhead Sprinkler 5.6 15.1 91.94 7.3 7 7.17 HEAD Open 6 0.165 -4.4 9.2 308 Overhead Sprinkler 5.6 15.3 91.94 7.4 7 7.17 HEAD Open 6.1 0.166 -4.4 9.2 307 Overhead Sprinkler 5.6 15.3 91.94 7.4 7 7.17 HEAD Open 6.1 0.166 -4.4 9.2 301 Overhead Sprinkler 5.6 15.4 91.94 7.6 7 7.17 HEAD Open 6.2 0.168 -4.4 9.2 310 Overhead Sprinkler 5.6 15.4 91.94 7.6 7 7.17 HEAD Open 6.3 0.168 -4.4 9.2 302 Overhead Sprinkler 5.6 15.9 91.94 8 7 7.17 HEAD Open 6.7 0.172 -4.4 9.2 313 Overhead Sprinkler 5.6 15.9 91.94 8.1 7 7.17 HEAD Open 6.7 0.173 -4.4 9.2 311 Overhead Sprinkler 5.6 17.7 91.94 10 7 7.17 HEAD Open 8.5 0.192 -4.4 9.2 305 Overhead Sprinkler 5.6 18 91.94 10.3 7 7.17 HEAD Open 8.8 0.196 -4.4 9.2 304 Overhead Sprinkler 5.6 18.1 91.94 10.4 7 7.17 HEAD Open 8.9 0.197 -4.4 9.2 303 Overhead Sprinkler 5.6 18.9 91.94 11.4 7 7.17 HEAD Open 9.7 0.206 -4.4 9.2 306 Overhead Sprinkler 5.6 19 91.94 11.6 7 7.17 HEAD Open 9.8 0.207 -4.4 9.2 309 Overhead Sprinkler 5.6 21 91.94 14.1 7 7.17 HEAD Open 11.8 0.229 -4.4 9.2 314 Overhead Sprinkler 5.6 24.2 91.94 18.6 7 7.17 HEAD Open 15 0.263 -4.4 9.2 318 Overhead Sprinkler 5.6 26.1 91.94 21.8 7 6.5 HEAD Open 16.9 0.284 -4.1 9.2 322 Overhead Sprinkler 5.6 28.3 91.94 25.5 7 7.17 HEAD Open 19.1 0.308 -4.4 9.2 321 Overhead Sprinkler 5.6 30 91.94 28.6 7 7.17 HEAD Open 20.8 0.326 -4.4 9.2 0018 Node 7.5 7.17 NODE -4.4 0017 Node 7.8 7.17 NODE -4.4 0016 Node 8.6 7.17 NODE -4.4 0010 Node 12.2 7.17 NODE -4.4 0007 Node 17.6 6.5 NODE -4.1 0006 Node 17.6 6.5 1 NODE -4.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge ft gpm/psi'/z gpm ftz psi psi gpm gpm/ftz psi gpm 0012 Node 18.7 6.5 NODE -4.1 0013 Node 19.6 6.5 NODE -4.1 0021 Node 20.5 6.5 NODE -4.1 0022 Node 23 6.5 NODE -4.1 0046 Node 39.4 7.17 NODE -4.4 0048 Node 42.6 7.17 NODE -4.4 0089 Node 50.2 19.06 INODE -9.6 0042 Node 51.2 19.25 NODE -9.6 0096 Node 53 18.02 NODE -9.1 0938-0 Node 59.6 5.28 NODE -3.6 0938-I Node 60.6 4.14 INODE -3.1 0939-0 Node 61.5 2.09 NODE -2.2 0939-I Node 67.3 1.93 NODE -2.1 0940 Node 67.9 0.5 INODE -1.5 H1 Outside Hose 100 69.6 -3 HOSE 0 100 0943 Node 69.6 -3 NODE 0 0944-0 Node 70.1 -3 INODE 0 0944-I Node 70.2 -3 NODE 0 0945 Node 70.4 -3 NODE 0 wi Supply -459.3 70.6 -3 SUPPLY 0 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 9 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 319 7.17 5.6 14.8 1.5 1x(90 ell)=4.02 5.75 100 7 316 7.17 5.6 14.8 1.728 4.02 0.0092 0 9.77 0.1 316 7.17 5.6 14.9 1.5 lx(tee-Br)=8.05 4.28 100 7.1 0018 7.17 29.7 1.728 8.05 0.0333 0 12.33 0.4 0018 7.17 11.6 1.5 1.8 100 7.5 310 7.17 5.6 41.3 1.728 0 0.0613 0 1.8 0.1 310 7.17 5.6 15.4 1.5 1.31 100 7.6 0017 7.17 56.8 1.728 0 0.1104 0 1.31 0.1 0017 7.17 15.1 1.5 4.97 100 7.8 0016 7.17 71.9 1.728 0 0.1711 0 4.97 0.9 0016 7.17 15.9 1.5 5.43 100 8.6 311 7.17 5.6 87.8 1.728 0 0.2477 0 5.43 1.3 311 7.17 5.6 17.7 1.5 lx(tee-Br)=8.05 10.71 100 10 0013 6.5 105.5 1.728 2x(90 ell)=8.05 16.1 0.3478 0.3 26.81 9.3 0013 6.5 145.3 2 1.79 100 19.6 0021 6.5 250.8 2.203 0 0.5297 0 1.79 0.9 0021 6.5 24.2 2 3.97 100 20.5 0022 6.5 274.9 2.203 0 0.6282 0 3.97 2.5 0022 6.5 26.1 2 3x(90 ell)=14.59 7.84 100 23 0046 7.17 301.1 2.203 14.59 0.7433 -0.3 22.42 16.7 0046 7.17 58.3 2 3.16 100 39.4 0048 7.17 359.3 2.203 0 1.0314 0 3.16 3.3 0048 7.17 0 2.5 lx(tee-Br)=11.46 12.93 100 42.6 0089 19.06 359.3 2.705 2x(90 ell)=9.12 20.57 0.3796 -5.2 33.51 12.7 0089 19.06 -91.4 4 2x(90 ell)=13.32 90.09 100 50.2 0096 18.02 267.9 4.31 13.32 0.0228 0.5 103.4 2.4 0096 18.02 91.4 4 2x(90 ell)=13.32 13.85 100 53 0938-0 5.28 359.3 4.31 13.32 0.0393 5.5 27.17 1.1 0938-0 5.28 0 4 1.14 59.6 DPV-1 0938-I 4.14 359.3 0 0 0.3948 0.5 *** 1.14 0.5 0938-I 4.14 0 4 2.04 120 60.6 0939-0 2.09 359.3 4.31 0 0.028 0.9 2.041 1 0.1 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 0939-0 2.09 0 4 0.17 61.5 Ames 0939-I 1.93 359.3 0 0 34.2337 0.1 Deringer 30 0.17 5.7 *** 0939-I 1.93 0 4 1.43 120 67.3 0940 0.5 359.3 4.31 0 0.028 0.6 1.43 0.0 0940 0.5 0 6 2x(90 ell)=34.91 9.12 140 67.9 0943 -3 359.3 6.4 34.91 0.0031 1.5 44.03 0.1 0943 -3 100 6 104.43 140 69.6 0944-0 -3 459.3 6.4 0 0.0048 0 104.43 0.5 0944-0 -3 0 6 0.88 70.1 Gate A2360 0944-I -3 459.3 0 0 0.1144 0 *** 0.88 0.1 0944-I -3 0 6 1x(tee-Br)=43.72 1.21 140 70.2 0945 -3 459.3 6.4 43.72 0.0048 0 44.93 0.2 0945 -3 0 8 124.91 140 70.4 W 1 -3 459.3 8.55 0 0.0012 0 124.91 0.1 W 1 70.6 Path No: 2 312 7.17 5.6 15.1 1 1x(tee-Br)=3.56 0.47 100 7.3 0017 7.17 15.1 1.049 3.56 0.1086 0 4.04 0.4 0017 7.8 Path No: 3 308 7.17 5.6 15.3 1.5 1x(tee-Br)=8.05 3.14 100 7.4 0018 7.17 11.6 1.728 8.05 0.0058 0 11.19 0.1 0018 7.5 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 11 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 4 308 7.17 5.6 15.3 1.5 8.3 100 7.4 307 7.17 5.6 3.7 1.728 0 0.0007 0 8.3 0 307 7.17 5.6 15.3 1.5 9.22 100 7.4 301 7.17 5.6 18.9 1.728 0 0.0145 0 9.22 0.1 301 7.17 5.6 15.4 1.5 1x(90 ell)=4.02 6.19 100 7.6 302 7.17 5.6 34.4 1.728 4.02 0.0436 0 10.22 0.4 302 7.17 5.6 15.9 1.5 2x(90 ell)=8.05 17.99 100 8 305 7.17 5.6 50.2 1.728 8.05 0.088 0 26.04 2.3 305 7.17 5.6 18 1.5 8 100 10.3 306 7.17 5.6 68.2 1.728 0 0.1551 0 8 1.2 306 7.17 5.6 19 1.5 lx(tee-Br)=8.05 7.59 100 11.6 0006 6.5 87.2 1.728 2x(90 ell)=8.05 16.1 0.2446 0.3 23.69 5.8 0006 6.5 37 2 7.13 100 17.6 0012 6.5 124.2 2.203 0 0.1443 0 7.13 1 0012 6.5 21 2 4.68 100 18.7 0013 6.5 145.3 2.203 0 0.1927 0 4.68 0.9 0013 19.6 Path No: 5 313 7.17 5.6 15.9 1 lx(tee-Br)=3.56 0.98 100 8.1 0016 7.17 15.9 1.049 3.56 0.1189 0 4.54 0.5 0016 8.6 Path No: 6 304 7.17 5.6 18.1 1 1x(90 ell)=1.43 10.13 100 10.4 0010 7.17 18.1 1.049 1.43 0.1508 0 11.55 1.7 0010 7.17 18.9 1 lx(tee-Br)=3.56 4.07 100 12.2 0007 6.5 37 1.049 1x(90 ell)=1.43 4.99 0.5676 0.3 9.061 1 5.1 0007 6.5 0 2 2.15 100 17.6 0006 6.5 37 2.203 0 0.0153 0 2.15 0.0 0006 17.6 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 7 303 7.17 5.6 18.9 1 lx(tee-Br)=3.56 1.13 100 11.4 0010 7.17 18.9 1.049 3.56 0.1638 0 4.69 0.8 0010 12.2 Path No: 8 309 7.17 5.6 21 1 lx(tee-Br)=3.56 14.89 100 14.1 0012 6.5 21 1.049 2x(90 ell)=2.85 6.42 0.1997 0.3 21.31 4.3 0012 18.7 Path No: 9 314 7.17 5.6 24.2 1 lx(tee-Br)=3.56 1.17 100 18.6 0021 6.5 24.2 1.049 1x(90 ell)=1.43 4.99 0.2582 0.3 6.16 1.6 0021 20.5 Path No: 10 318 6.5 5.6 26.1 1 lx(tee-Br)=3.56 0.5 100 21.8 0022 6.5 26.1 1.049 3.56 0.2985 0 4.06 1.2 0022 23 Path No: 11 322 7.17 5.6 28.3 1 9 100 25.5 321 7.17 5.6 28.3 1.049 0 0.3456 0 9 3.1 321 7.17 5.6 30 1 lx(tee-Br)=3.56 4.59 100 28.6 0046 7.17 58.3 1.049 3.56 1.3168 0 8.161 1 10.7 0046 39.4 Path No: 12 H1 -3 100 6 lx(tee-Br)=43.72 1.76 140 69.6 0943 -3 100 6.4 43.72 0.0003 0 45.48 0.0 0943 69.6 Path No: 13 0089 19.06 0 4 5x(90 ell)=33.29 296.04 100 50.2 0042 19.25 91.4 4.31 33.29 0.0031 -0.1 329.33 1 0042 19.25 0 4 lx(tee-Br)=16.69 385.05 100 51.2 0096 18.02 91.4 4.31 4x(90 ell)=26.63 43.33 0.0031 0.5 428.381 1.3 0096 53 File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 13 Job:SEATTLE GALVANIZING PLANT Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/z) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 30.25 ft/s occurs in the following pipe(s): (0048-0046) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 14 Job :SEATTLE GALVANIZING PLANT Device Graphs Pressure vs. Flow Function Design Area: 3; Supply Ref.: W1; Supply Name:W1 90 85 80 75 70 65 60 y 55 >Z 50 L y 45 to N 40 L d 35 30 25 20 15 10 5 0 0 0 0 0 0 0 0 0 0 0 Flow,gpm Pressure Loss Function Design Area: 3; BFP Ref.: 1009 (Ames Deringer 30, Size = 4); Inlet Node: 0939-I; Outlet Node: 0939-0 17.15 16.15 15.15 14.15 13.15 12.15 y 11.1 Q' 10.15 L 7 9.1 N 8.1 L. a 7.1 5.7 psi @ 359.3 gpm 6.1 5.1 4.1 3.1 2.1 1.1 0.1 0 o c o 0 0 0 0 0 0 0 0 0 0 0 n Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright 0 2002-2012 Tyco Fire Protection Products Page 15 Job:SEATTLE GALVANIZING PLANT Device Graphs Pressure Loss Function Design Area: 3; DPV Ref.: 1010 (DPV-1, Size = 4); Inlet Node: 0938-I; Outlet Node: 0938-0 a.9 7.9 6.9 Nl 5.9 >Z d L N 4.9 rn d L d 3.9 2.9 1100, 0-00 1.9 0.5 psi @ 359.3 gpm 0.9 0 0 0 0 0 0 0 0 0 0 o c o 0 c o c c c o I o 0 0 0 M � 7 vl vl i0 r W 00 O N C Flow,gpm Pressure Loss Function Design Area: 3; Valve Ref.: 1011 (Gate A2360, Size = 6); Inlet Node: 0944-I; Outlet Node: 0944-0 y 0.766 Q d 7 N rn d a 0.266 0.1 psi @ 459.3 gpm 0 o c c o 0 0 0 c o N M � Vl Vl Flow,gpm File:C:\Users\yates\Documents\dwg2\burns\Arlington Galvanizing Plant\Submittal\Arlington Galvinizing Plant.dwg Date 9/6/2023 Copyright©2002-2012 Tyco Fire Protection Products Page 16 © NEW 6"D.I. BY OTHERS Q STORAGE LOADI G 39'-6" 70'4" 39'-6" CANOPY DOCK �1 INES FOLLOW SLOPE 6" BELOW PURLINS V-10 V-10" I�RANE SUPPORT CF NE S PPORT INIMUM HEIGHT 17'9" MINIMUM HEIGHT 17'9"� SCOPE OF WORK IN PIPIN 6" BELOW CEILIN THIS SUBMITTAL - EXISTING BUILDING - OTTOM OF CRANE RAIL BEAM Z.T. OF CRANE RAIL BEAM NO WORK THIS SUBMITTAL 0943 ® H, o � 123 NEW 6"D.I.BY OTHERS 2 BUILDING SECTION Scale:1/8"=1' 67TH AVE NE W1 UNDERGROUND NOTES: Source information BURNS FIRE PROTECTION SYSTEMS, INC. TO START AT FLANGE INSIDE OF THE BUILDING. Date of Flow Testl Info:83112023 Locatbn of flow test data BURNS FIRE PROTECTION SYSTEMS, INC. EXPECTS ALL UNDERGROUND 67th ave NE PIPING TO BE FLUSHED PER NFPA STANDARD #13 AND NFPA STANDARD 24 Sounafflow Nst' . AND THAT THE UNDERGROUND SYSTEM WILL BE INSTALLED MEETING THE modeled flow by Ryan Momson-Adington Water PROCEDURES AND STANDARDS SET BY THE WASHINGTON STATE FIRE Source DataP' Pressure I Fbw Pressure Flow MARSHAL AND LOCAL UTILITY REQUIREMENTS 79.00 0.00 WHEN NFPA CERTIFICATE IS SUBMITTED DOCUMENTING 66.00 5000.00 SITE PLAN THE PROPER INSTALLATION AND FLUSH OF THE UNDERGROUND, BURNS 1 FIRE PROTECTION SYSTEMS INC., WILL CONNECT THE INTERIOR AUTOMATIC FIRE SPRINKLER scale:1"=40' SYSTEM TO THE UNDERGROUND FIRE SERVICE AT THE INTERIOR SUPPLY FLANGE. Calculation results for Design Area 1 -SW CORNER This system as shown on Burns Fire Protection.Inc company print no dated 5113116 Calculation results for Design Area 3 -lower mew-nine for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. This system as shown on Burns Fire Protection,Inc company print no dated 5/13/16 contract no is designed to discharge at a rate of 0.15 gpni(L/min/ri of floor area over for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. a maximum area of 1950 fl2 when supplied with water at a rate of 751.3 gom at 66.9 psi at the base of the riser. contract no is designed to discharge at a rate of 0.1 gpni(L/min/m2)of floor area over Hose stream allowance of Is Included in the above. a maximum area of 1950 IF when supplied with water at a rate of 459.3 opm at 70.6 psi at the base of the riser. Occupancy classification:OH1 Number of heads flowing:19 Hose stream allowance of is included in the above. STRUCTURAL STEEL BEAM Commodity classification: System Type: Dry Occupancy classification:Ih Number of heads flowing:19 Dr Maximum storage height: Maximum velocity: 17.43 ills s Commodity classification: System Type: Storage arrangement: Maximum storage height: Maximum velocity: 30.25 ft/s Z-PURLIN Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 66.9 psi Storage arrangementV-13 : Flow from Overhead sprinklers: 501.3 gpm Pressure Available at Source: 78.6 psi Flow from In-Rack sprinklers: 0 gpm Pressure Required at Source: 70.6 psi Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 11.7 psi Flow from Overhead sprinklers: 359.3 gpm Pressure Available at Source: 78.8 psi G TYPE BEAM CLAMP Flow from Outside Hoses: 250 gpm Flow from Inside Hoses: 0 gpm Su plus Pressure at Sou ce: 8.3 psi SELF TAPPING + Other fixed flows: oaom Flow from Outside Hoses: 100 gpm W/RETAINING STRAP 'F Total flow in system piping: 751.3 gpm "SAMMY"SCREW SWDR, 3/8" -4" & SMALLER PIPE O� Addit tonal flow at/beyond source: 0a0 m Total fixed sy 3gpm Total of all flows: 751.3 gpm Total flow fl system piping: 459.3 gpm Additional flow alPoeyond source: 0 oom Total of all flows: 459.3 gpm 3/8" A.T.R.-4" & SMALLER PIPE Calculation results for Design Area 2 -STORAGE CANOPY This system as shown on Bums Fire Protection,Inc company prim no dated 5/13116 for SEATTLE GALVANIZING PLANT at 18520 67th Ave N.E. �l contract no is designed to discharge at a rate of 0.1 gpm/W(L/min/m2)of floor area over 3/8 A.T.R. a maximum area of 1950 W when supplied with water at a rate of 669.6 apm at 70.5 psi at the base of the riser. Hose Stream allowance of is included in the above. Occupancy classification:OH2 Number of heads flowing:16 RING HANGER a Commodity classification: System Type: Dry n Maximum storage height: Maximum velocity: 23.43 fVs O NN Storage arrangement: 6 3x2Yh Flow from In-Rack sprinklers: 0 gpm pressure Required at Source: 70.5 psi RING HANGER RED a Flow from Overhead sprinklers: 419.6 gpm Pressure Available at Source: 78.7 psi i0 COUPLI G � n� Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 8.2 psi Flow from Outside Hoses: 250 gpm HANGER 12 HANGERS AT ROOF PURLINS ` <o Other fixed flows: Oopm # #0 4 MAIN HANGER A T BEAMS 'F J'F Total flow in system piping: 669.6 gpm N.T.S. as a "F Additional flow,at/beyond source: 0 opm Total of all flows: 669.6 gpm " RISER OOM 3/8x2" BOLT NUT AND WASHER WORK PERFORMED BY BURNS FIRE PROTECTION SYSTEM,INC.CONSISTS OF: welght/ft mOxim um load at NOT LESS THAN 2" NOMINAL WIDTH. water filed hanger maximum. SIZE PIPE TYPE SCHED. NOM ID pipe � Ocing spacin yy EXTENDING NEW DRY SYSTEM PIPING TO ALL AREAS OF BUILDING AS REQUIRED BY NFPA#13 INCHES / INCHES (pounds) eetJJ ounds ( 1 1/2" ) rd>) SYSTEMS HYDRAULICALLY DESIGNED FOR ORDINARY HAZARD GROUP 1.15 GPMI 1950 4 SQ.FT.00CUPANCIES,IN GALVANIZING AND DIPPING PLAN 1" SCH 40 1.049 2.05 12'0" 24.6 SYSTEM DESIGNED GROUP II.20 GPM/1950 SQ.FT.UNDER STORAGE AND LOADING DOCK CANOPIES 1"1/4" SCH 40 1.380 2.93 12'0" 35.16 LIGHT HAZA FM / SPACING OFRSPIRINKLERS BASED ON 130 SQ.FT.MAXIMUM,EXCEPT IN OFFICE AREAS 225 SQ.FT. 1 1/4'- EDDYFLOW 1.536 5.1 15 0" 56.85 O ASC FIG 55r=0��\ / NOT LESS THAN 3" SIDE BEAM BRACKET\ MAXIMUM 3 1/2 EDDYFLOW 2.314 7.1 15'0" 76.5 NOMINAL THICKNESS TAPPED FOR 3/8" BOLT 4 EDDYFLOW 3.314 10 8 15'O" 162.9 EDDYFLOW 4.31 10.86 150" 601-2 GENERAL NOTES: 6 SCHED 10 6.36 23.03 15'0" 345.45 c2 1/2) $ SCHED 10 B25 40.08 15'0" 6012 RISER DETAIL 1/F P 1 1. DESIGN AND INSTALLATION TO CONFORM WITH NFPA 13, 2019. 2. ALL MATERIALS TO BE NEW AND UL OR FM LISTED. 3/6'D"A. PIPING SYMBOLS: A B 0 1' 2' 3' 4' 3. PROTECTION OF SPRINKLER FROM PAINT BY OTHERS. t'0"ATR 1/z^=1'a^ ��� 4. ALL PIPE THREADED PIPE TO BE BLACK SCH 40 PIPE. 2" MIN. A.T.R.WELDED TO 5. ALL NEW GROOVED PIPE WITH WELDED OUTLETS AND JOINED NTH GROOVED EA.END COUPLINGS TO BE EDDYFLOW. PENETRATION SYSTEM RISER/SUPPLY Components f Approximate Hanger Location 6. FITTINGS TO BE BLACK MALLEABLE IRON OR PAINTED GROOVED. GST 20 FOR 1-2 1/2" PIPE Nt"TRAPEZE ASC/ANVIL FIG 69H RING TYP. 1 6"SUPPLY 7. ALL PIPE ELEVATIONS ARE TAKEN FROM CENTER LINE OF PIPE AND ARE AS f Approximate Bracing Location 3/8°A.T.R.FOR UP To 4"MAIN 2 6'GROOVED BY FLANGE ADAPTER MARKED ON THE DRAWINGS. -�- Approximate Location of Grooved Coupling GST 25 FOR 4' PIPE 3 6x4"REDUCER 8. SYSTEM IS DESIGNED TO DELIVER PER THE NOTES ON THE PLAN. FOR VERTICAL USE. 1/2"A.T.R.FOR 6"MAIN 9. ALL SWAY BRACING TO BE 1" SCH40 PIPE FASTENED PER APPROPRIATE DETAIL. INSTALL IN CENTER 4 4"AMES DERINGER 30 DOUBLE CHECK DETECTOR ASSEMBLY 10. ALL GROOVED COUPLINGS ARE TO BE RIGID UNLESS NOTED OTHERWISE. +0-0 Elevation from Floor to Centerline of Pipe OF LOWER FACE. 5 4"TYCO DPV-1 DRY VALVE WITH ACCELERATOR 11. GROOVED COUPLINGS TO BE FLEXIBLE COUPLINGS ON MAINS WITH DROPS -0 BOJ Elevation down from Joist to Centerline of Pipe 6 RISER MOUNT AIR COMPRESSOR WITH AIR MAINT.DEVICE-1200 GALLON SYSTE EXCEEDING 7' IN LENGTH. GST PIPE HANGER FOR WOOD MAIN OR 7 (2)21/2"HOSE VALVES FOR FORWARD FLOW TEST OF BACKFLOW PREVENTOR 12. FLOW AND TAMPER SWITCHES TO BE PROVIDED AND INSTALLED BY BURNS FIRE -0 BOB Elevation down from Beam to Centerline of Pipe t'11d �Y/ BRANCH LINES 8 4"CV-1 CHECK VALVE(9.63"T.O.) PROTECTION SYSTEMS, INC. e/, PIPE SPAN A B ASPAIJED EMBER TRAPEZE MODULAS MODULAS 9 ILL MOUNT 13. ALL ELECTRICAL WIRING TO BE PERFORMED BY OTHERS. (0'-0") Center to Center Dimension of Pipe as T1 2Ys SPA4'0 t'a" 2'8" PAN 1Ys"SCHED 40 .33 .27 10 1.ELECT" ELECTRIC BELL 14. FLOW SNATCHES AND TAMPER SNATCHES AS REQUIRED BY CODE. FOR PIPE IN supported by dimensional lumber 15. THE OWNER IS TO PROVIDE MONITORING AS REQUIRED.. O'-0" Cut Dimension of Pipe T2 216 5'0" 3'2" ,',0" 4'6" 11 12 HEAD SPARE HEAD BOX 16. THE NEW ELECTRIC BELL SHALL BE MOUNTED AT 10'-0" ABOVE AND WITHIN 4' 2"SCHED to .34 1 Hydraulic Reference Point CERT. *F INDICATES FLEXIBLE COUPLING HORIZONTALLY OF THE FIRE DEPARTMENT CONNECTION. #86528 ADJUSTED SPAN FOR PIPE LOCATED WHERE TRAPEZE IS NOT CENTERED BETWEEN SUPPORTS BASE ON FOLLOWING FORMULA BURNS FIRE PROTECTION SYSTEMS,INC.TO PROVIDE ALL FLOW AND 17. HEADS ARE TO BE SPACED PER NFPA13 David Yates C.E.T. 4(A)(8) TAMPER SNITCHES-ELECTRIC WIRING AND SYSTEM MONITORING TO BE 18. ALL PENETRATIONS THRU RATED WALLS SHALL BE FIRECAULKED. o • Rise/Drop N.I.C.E.T. Level IV PROVIDED BY OTHERS 19. THIS BUILDING IS MIXED HAZARD OCCUPANCY. Fay PR0'="o" 20. TOTAL NUMBER OF NEW SPRINKLERS= 433 ® Main Sprinkler Riser ExcwEERwc TEceprowcv A+B PATER-BASED SYSI'EYS WYOUT #62 TRAPEZE HANGER DETAIL 21. TOTAL AREA OF BUILDING IS APPROX. 41,965 SQ.FT. NAT ONA N TUTS E N.T.S. 3 (NAS) No Automatic Sprinklers CERT FCAT ONr ENGINE- RISER TECFe101AGR:e. Scale:1/2"=P (NTS) NOT TO SCALE NOTES REVISIONS SPRINKLER SYMBOLS NOTES AND DATE DESCRIPTION BY DETAILS ......... .""""WASHINGTONSTATE......... SYM CNT POSITION FINISH TEMP K NPT SIN MFO. MODEL BURNS FIRE PROTECTION SYSTEMS SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY X 364 uPR WHITE 20o S.6o 1/2' TY3131 T1co TY-FRB FIRE PROTECTION SPRINKLER SYSTEMS: 0 3e JUPR ICHROME 1200 1 5.60 1/2' 1 TY3151 IT1co I TY-B PERMIT NO. VJ 7i 4 30 SIDE WHITE 200 5.60 1/2' TY3351 T1ao TY-B P.O.B. 1110 CONTRACT NO. :David � 18520 67TH AVE NE 2608"0898"C Level /1 ISIDE WHITE 1200 1 5.60 1/2' ITY3331 IT1a, I TY-FRB Burns Fire Protection Systems,Inc. GRANITE FALLS, WA ARLINGTON APPROVAL CITY OF ARLINGTON , WA 98223 DRAWN BY D.YATES M :B SFPB nu g,6/23 425-388-0124 SCALE NOTED E>area: , :Signature Date 12/312 r DATE 9/6/2023 ................................ DESIGN UESTIONS 360-591-5396 Q CONTRACTOR: Rs"sm FP 1 PcoTlsp OP IDGE 2-0 e Design Areal Dry System DA Area 1981.a1 17'7" .5" P RLIN BDP 16' .5� STORAGE CANOPY IN S UP LOPE AT Demand Calculations using Hazen-Williams Method 203 Omupancy Classirsetion: OH2 Design ATea Density: 0.1 a 207 06 205 11 0916 g'T a 20 P - AddNonalOutsideHoss: 0 _ „ 1 •6" —M IN AT 1'4 BOP DesiNotes ATea S¢e. 1950 - 9-6z eh e-e'z NI LINES FOLLOW 2 SLOPE 6"BELOW PURLINS T1 " LOADING ,', N r1 NES B CANOPY 1 1 1 1 STORAGE 000 2 214 212 211 09 91 aka CANOPY &V EXISTING BEAM �T 15-8 'g m 2 , T2 r IS-9 1 I B 1 . -° N-0 I 0 4 0024 5-0z 61 II-z " Im 0-0Pz - 1 91 D ��,`• NONCOMB STIBLE AWNING NO STORAGECO ECTIN A NIN 20 — 1 18-1 a 0141 0140 0138 0- 10-0 I 9-6 I - /-3 /-3 I 3-6 7-fi I 3-6 fi-6 fi 0- 10-0 }Il�z 19-0 1 4" 00421D" IB-014.. r VP�VE 19-J 2-Ms 4 4 J a J Nz 6-]k _ 0 „v0-0 _ „_ 10-0 _ 6- I-0 f e 1 0 _ 9- e 4 ]-Imz _ 9- _ la. 10-0 94 101 c 4 0 OP 0,1A ORp\N „" „.. ��- 1 1 1 1��_ 1 1 � � �_ 1 _ 1 1 }s: „ 19-z 1 4 •25 1 2 1 — - - Q Q - - Q Q - - Q Q - - Q Q - - Q ¢ - - ¢ Q - - Q Q - - Q Q - - - - Q Q - - Q - O - a W W W W W W W W W W W W W W W W W W P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 m m P2 P2 m m P2 m z o z o z o z o z o z o z o z o z o D a o a o a o a o a o a o a o a o J( a o ;g rr of m rr rc m of m of PI N C) N C) N N N N N N N P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 02 a P2 P2 P2 P2 P2 P2 P2 m P2 P2 F�2 f05 -S 110 `� 5 11 D. S D. -.S D. -S D. -S D. -S D. -S D. -S .b .b .b ORp\N NP\'VE BOI 01\A P 2 P2 P2 P2 P2 P2 P2 P2 P2 P2 lo-a }mv g to-6 _ _ _ CHANNELS 6"� ' }a: 104 11 ,16 -FLOOR STEPS 5" O -d _1 -d ns J r .m 5,z- 3 Y d io-i 03^ 1 f 1 113 117 3/S3 0 2 2 2 2 _ - - 2 _ '2 m r 5' 0" 5' 0" d RAIN VALVE P3 O m OWN TO LOWER p MEZZANINE PIPING m ,oz 7 � 1 116 B.2, P3 LL h�l M Desi n Area 1 D S stem w w w w w w w w is-u a 4 SW CORNER _ _ _ _ _ _ _ _ _ _ Demand CalculiLions using HazemWilliams Method 3 Ccclpancy Clasthcadon: OH, 101 106 0 Design Area Desity: 0.15 (E) OFFICE Additional Outsi]a Hose AREA TO io Design Area Si : 1950 ,t, P3 REMAIN Notes: K = A ANa q - - - 10'- - - - 5-0- -o,• 0•_0•• - - - - '�� a - - - - - - - - - - - - ' �ro c� 110'o LEVEL - 2n ..—.i SPECTORS TEST P3 PURLIN SCHEDULE p3 MARK SIZE NOTES P1 8Z16 (E) ROOF PURLIN, DO - - - 3 - - - - - - - - - - - NOT HANG SPRINKLERS -` FROM P1 PURLINS P3 P2 8Z16 (E) CRANE W-RAFTER PURLIN, HANG 8.1 SPRINKLER BRANCH LINES PER PLAN BOTTO F CRA RAIL 6'7" AND KEY NOTE 1 P3 P3 8Z16 (E) W-RAFTER PURLIN, HANG m\ _ SPRINKLER BRANCH LINES PER PLAN P3 o AND KEY NOTE 2 D g KEY NOTES: cn 9�53 TTOM GRAN RAIL 1 D TOP 19.1 T =S `ARP\N VP�'vE 1 2"0 PIPE MAX SPRINKLER BRANCH LINE LOCATION GRID O - _ - _ - _ _ - - _ _ W c A-B &B-C. HANG SPRINKLER LINE FROM EACH P-2 0 PURLIN (SPACING VARIES) 2 2"0 PIPE MAX SPRINKLER BRANCH LINE LOCATION GRID q B-C. HANG SPRINKLER FROM EACH P-3 PURLIN \ \ \ \ e+ VE 1 oRp\N�P 5'-0" O.C.) V4\j 3 6"0 PIPE MAX SPRINKLER MAIN LINE LOCATION. HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 f P2 c -MAIN ALONG SIDE SPRINKLER LINE FROM (E) CRANE W-RAFTER ONLY. DO OF BEAM NOT HANG FROM (E) 2C RAFTER OR (E) PURLINS. SEE SUPPORT FROM PLAN NOTE 5 O TOP FLANGE OF BEAM = 4 6"OPIPE MAX SPRINKLER MAIN LINE LOCATION. HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 D SPRINKLER LINE FROM (E) W-RAFTER ONLY. DO HANG P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 � �2 P1 FROM FROM (E) PURLINS. SEE PLAN NOTE 5 -0, a -a �a, a -a ��, a -a ��, a -a �a, -a ��, a -�, -�, a -�, -�, a -h 02 -�,� a a w a w a w a w a w a w a w a a w a w a w a w m m m m m m m m m m m m m m m m m m m m m T m 5 BLOCKING PER 4/53.0 AT P2 MID-SPAN Z O Z O Z O z O Z O Z O z O Z z O z O z P2 a m P2 x P2 a P2 P2 P2 P2 a P2 a P2 P2 a P2 P2 `a m m m � -d cb U -d cb U -d cb U -d cb U -d cb U -d ab U -d cb U -d -b cbc7 N N n n N N V NO n ♦ .m 0936 ..}s: OP�Sa bR Ix a i ,I, f4a 4 -.S ? V", �g"f ?4 4 J 4 4 ,o-o ,o-o lo-g e-s= _ -- --- - b 0094 aos6 FPl 2 2-6 -6 }6 -6 6 -6 81-6� 6- 3- 10-0 ]- 2- I 8- 9- 0-0 9-6 0-0 10-0 2 ,U-0 0939 A --__ - -- ---_- 0940 1&-019^s • 7- WALL MOUNT F.D.C. i0o--oi i p 20'-0" 20'-0" 20'-0" 20'- " 20'-0" 20'-0" 20'-0" 20'-0" 2 '-0" 21'-0" 20'-0" 20'-0" �°-0�° oa�EroauN a"e _ CERT.#86528 25" WALL GERTS suwoa,raoN,o>ovaFun David Yates C.E.T. O O O O O O O O O 2 O N LC E T Level IV 1 2 3 4 6 7 8 9 10 11 2 @tG1NEEnWG TECfLN01AGY D IN VALVE " PURLIN IN MIDDLE xATaR-6Asm srsraus umuT NATIONAL P,STNVTE FOR fPl 3 �Taeoio g NcweeRec 240'-0" SEISMIC ZONE OF INFLUENCE #1 s. N NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN ••--••• DATE DESCRIPTION BY .�, N N Ni M K N IN MG. MODEL BURNS FIRE PROTECTION SYSTEMS ROOF LEVEL WASNINGTON STATE••••--•' 364 UPR WHITE 200 5.60 ,/2" TY3,3, ryro ,~-FRD SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY Q 38 uPR CHROME zaa 5.60 ,/2" TY3151 Tyco TY-B PERMIT N0. FIRE PROTECTION SPRINKLER SYSTEMS; Nr E. d 30 510E WHITE 200 5.60 t/2" TY3351 Tyco TY-B P.O.B. 1110 CONTRACT NO. David Yates ., 910E WHITE z00 5.60 ,/2" TY3331 Tyco Tr-FRB 18520 67TH AVE NE 2605.0898•C Level Burns Fire Protection systems,Inc. GRANITE FALLS, WA APPROVAL ARLINGTON, WA 98223 DRAWN BY D.YATES S B SFP8 Du 9/6/23 425-388-0124 SCALE 1/8" = V-0" ' Expires: , Signature Date 12f31/2 DATE 9/6/2023 ---•--"••••••••••••••••••• DESIGN QUESTIONS 360-591-5396 CONTRACTOR: REN6 3 FP 2 PLOT,ED 9'-5" DA Name:3 DA Area:2022.68 1 1 4 1 1 4 0- 10-0 10-6 2-6 1- 1 304 309 WOMENS 322 -2 z BELOW FOLLOWCEILI G SLOPE 1 1 OTS WITH 1'DEEP BEAM 6" M _ 1_ N 12" DEEP BEAM 1'4 fl *5 1 2 Boo O 1-5 N Cn 6-4 AFF °° DROP IN WH CLOSET 114 1' O 01 1a-10 REF 4" N MENS 61 6 AFF 321 TO LINE BELOW STAIR o- 10-0 10-s 2-s 1 2 STOR 0010 CORRI O 6-6 REF SIN o, 2 1 314 318 002 4„ 2 8-2'2 &2' 0012 M41 SLOPED CEILING NN6-512Ce. 12 r- _ CEILNG STARTS AT 68 2 Ln *6 BODAFF a2 J 2 h 2 2 q2 - " � L � 7_2 REFTO O 2- ° °) 7-11 z -8 N °�9l z 3-11' w 112 0 14'-7 1/4" 0-6 0 0021 x &� o, -9 3-2 0-1 2 3-7 1 1 306 0013 0�. . - 2 0046 048 N - z 7 3 7 BDD i -6 1 1 16 REF (D OFFICE " ^10 z 2-4 N 311 ` � DRUM DRIP DRAIN CN s "' Ln *s BOD IN WATER HEATER 7-2 AFF CLOSET " 7-2 REF —_ 305 coRRl 16 LOBBY LINE BELOW STAIRS 112 1'2 112 N M 1-112 3-3 g_glz 5-1 OPEN TO ABOVE N 1 " 0-10 r ° " 6-5 3 2 0017 CN Design Area 3 Dry System CEILINGS CORRIDOR 1 lower mewzzanine 307 308 0018 316 2-6 s-1 2 o Demand Calculations using Hazen-Williams Method Occupancy Classification: Ih o 1,z 1'2 1,z 1'2 3-1'z 4-3 z 2-5 Design Area Density: 0.1 3-11z 301 9-2' 7-912 0-6 Additional Outside Hose: 0 OFFICE OFFICE OFFICE Design Area Size: 1950 OFFICE Notes: calulations include all of lower mezzanine ceiling 71011 (� 2ND MEZ UNLESS NOTED OTHERWISE CEILING ELEVATION: MAIN PIPE ELEVATION: BRANCH PIPE ELEVATION: ELEVATION FROM JOB REF: 8'6" 1 LOWER MEZZANINE PIPING UPPER MEZZANINE PIPING CERT.#86528 Scale: 1/4"=1' 2 David Yates C.E.T. Scale: 1/4"-1' N t Fo,R T. Le-1 N — @tG1NEERWG TECfR,OLOGY AATRR-BA6®SY6TRY6 LAYOUT NATIONAL R,SITTUTE FOR CRRTR+ICAT[ON RI II,GRiRRRING TEC@IOIAGIRB. N NOTES REVISIONS SPRINKLER SYMBOLS MEZZANINE -•----• DATE DESCRIPTION BY W NI H M K N IN M D. MODEL BURNS FIRE PROTECTION SYSTEMS ROOF LEVEL WASNINGTON STATE......... WHITE 200 e.6o ,/2" TY3,3, Tyco ,~-FRD SEATTLE GALVANIZING COMPANY CERTIFICATE OF COMPETENCY CHROME 20a 5.60 ,/2" TY3151 Tyco TY-B PERMIT NO. FIRE PROTECTION SPRINKLER SYSTEMS;NrE. WHITE 2aa 5.60 t/2" TY3351 Tyco TY-B P.0.B. 1110 CONTRACT NO. pevidYete. WHITE 200 5.60 ,/2" TY3331 Tyco Tr-FRB 18520 67TH AVE NE 2605.0898•C Level F Burns Fire Protection systems,Inc. GRANITE FALLS, WA APPROVAL S B SFPB ou 9623 ARLINGTON, WA 98223 DRAWN BY D.YATES Eyre.: , 425-388-0124 SCALE 1/4" = V-0- Sgneture-----"•,--Date--_-12fbV2- : DATE 9/6/2023 DESIGN QUESTIONS 360-591-5396 CONTRACTOR: REN6m FP 3 PLo ED Permit#: 5648 Permit Date: 10/17/23 Permit Type: FIRE SPRINKLER Project Name: Arlington Galvanizing Plant Applicant Name: Burns Fire Protection Systems, Inc. Applicant Address: PO Box 1110 Applicant, City, State, Zip: Granite Falls Contact: Keith Kyle Phone: 4259055780 Email: keith@burnsfire.com Scope of Work: Burns to install full NFPA 13 Sprinkler system starting at flange inside riser room Valuation: 149900.00 Square Feet: 41965 Number of Stories: 1 Construction Type: 111A Occupancy Group: B; Business ID Code: Permit Issued: Permit Expires: Form Permit Type: FIRE SPRINKLER Status: VOID/WITHDRAWN Assigned To: Ameresia Lawlis Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200100200 18520 67TH AVE NE 349 Other Fabricated Metal Products NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Burns Fire Protection Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION COA 603 467 812 Systems CONTRACTOR Burns Fire Protection Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION Labor&BURNSFP841DU Systems CONTRACTOR Industries Burns Fire Protection Audra Williams 360-691-2235 PO Box 1110 CONSTRUCTION NICET 86528 Systems CONTRACTOR Fees Fee Description Notes Amount Enter 1 if permit is for:fire alarm or fire Web Only-Fire System Plan Review sprinkler $200.00 Credit Card Service $6.00 Fire Sprinkler System Commercial NFPA 13/13R 625+ 100=725 x2=1450 $1,450.00 Fire System Plan Review Table 4-2 1246.86-200=1046.86 $1,046.86 Total $2,702.86 Attached Letters Date Letter Description 10/17/2023 Web Form-Building Application Payments Date Paid By Description Payment Type Accepted By Amount 10/17/2023 XBP Con£ $200.00 156391372 10/17/2023 Alan D 156391372 Hannah Hardwick $6.00 Outstanding Balance $2,496.86 Notes Date Note Created By: 10/18/2023 Pending hard copies Ameresia Lawlis 10/18/2023 Pending plan review fee Ameresia Lawlis Uploaded Files Date File Name 10/18/2023 17235064-RE Arlington Galvanizing Plant sprinkler permit submittal.msg 10/17/2023 2d9e85efc02d5075aa60alb7bll49dd8 arlington galvanizing�lant - remote area l.pdf 10/17/2023 99919e7b096aef5a6ce66f6c55ea3a71 arlington galvanizing_lant - remote area 2.pdf 10/17/2023 03e410549bf9ea8alebde65cb43fa412 arlington galvanizing_p ant - remote area 3.pdf 10/17/2023 5ed66b3b523dcc40ac98946d5lb4dc69 arlington galvinizing plant submittal 9 6 2023.pdf 10/17/2023 cb18744710fcc26809d4faa47fcde418 arlington galvanizing_lant - application.pdf 10/17/2023 e9eb017682be3fl3b2164fd76flc4d23 arlington galvanizing plant - braces-to-crane-support-beams-9-5-2023.pdf 10/17/2023 lc743f775735b4a8lcf9c98b05f4e394 arlington galvanizing_plant - material submittal.pdf